216041 CBJTC Museum Storage Addendum #2.pdf
PDF 4 MB Posted
- Attached to
- 216041 CBJTC Museum Storage Facility, Bldg 3016
- Solicitation number
- ITB-05385
- Issued by
- Clay County, Florida
About this file
This document is an addendum related to a state and local contract opportunity for the construction of the CBJTC Museum Storage Facility, Bldg 3016 in Starke, Florida. The project involves the repair and renovation of an existing building located at the Camp Blanding Joint Training Center to provide storage for the Camp Blanding Museum's sensitive artifacts. Key details include the removal of the existing building structure down to the foundation, construction of a new 3,000 square foot climate-controlled structure utilizing the existing foundation and slab, and the installation of chain link fencing and gates as partitions around the storage areas. The contractor is responsible for obtaining required building permits, except for the Fire Marshal permit which will be handled by the state. Bids are due on June 27, 2023 at 2:00PM.
The estimated construction cost is $807,239. The document also includes revised specifications for the chain link fencing and gates, as well as details on the revised architectural and structural drawings, including the removal of the modular vault and additional security measures for the Arms Room. Bidders must acknowledge the addendum on the Exhibit 4 - Bid Proposal Form.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Florida Army National Guard
Construction & Facility Management Office
ISSUED ADDENDUM
Rev. 11/2018
Date June 19, 2023
ADDENDUM Number 2
Project Number and Name 216041 CBJTC Museum Storage Facility, Bldg 3016
Invitation to Bid Date May 25, 2023
Number of Attachments 2
Bid Opening Date and Time Tuesday, June 27, 2023 2:00PM
From: Department of Military Affairs, CFMO Contracting Office
This addendum and the listed attachments forms a part of the contract documents and modifies the original bidding documents. Acknowledgement of this addendum in Exhibit 4 - Bid Proposal form is required.
Concerns with this addendum should be addressed to:
ng.fl.flarng.list.cfmo-contracting@army.mil
Answers to Questions (Q) / Clarifications (C) / Modifications (M)
Q1-9. Answered on attached Addendum #2 from A/E of record.
M1. Scope of work called for the Vault to be owner provided/Contractor installed.
Drawings for construction of Vault will be updated with this Addendum #2, only owner provided item is the Vault Door. Pictures of Door was provided with Addendum #1.
M2. Change of Alternate Bid Items (WAS ABI #1 Chainlink Fence Partition, ABI #2 Splitface CMU – NOW ABI #1 Chainlink Fence & Gates REVISED, ABI #2 Building/Wall Sections), revised Exhibit 4 provided with this Addendum #2.
Attachment List
1. 216041 CBJTC Museum Addendum #2 COMBINED.PDF
2. 216041 CBJTC Museum Ex 4-5 REV.PDF
END OF ADDENDUM #2
mailto:ng.fl.flarng.list.cfmo-contracting@army.mil
Addendum No. Two
BHA #202301
ADDENDUM NO. TWO
To the Plans and Specifications for:
CBJTC Museum Storage Facility
Camp Blanding Joint Training Center
Starke , FL
For FLORIDA DEPT. OF MILITARY AFFAIRS
Prepared By: ARCHITECT
Bhide & Hall Architects, P.A.
1329-C Kingsley Ave.
Orange Park, FL 32073
Certificate No. AAC000569
Date: June 15, 2023
Index:
Number Discipline Topic
1 Non-Technical RFI #001 Reply
2 Architectural Specifications Table of Contents revised.
3 Architectural Specification Section 10 22 13, Security Barriers (ABI #001) removed from project.
4 Architectural Specification Section 32 31 13, Chain Link Fences & Gates
(ABI #001) revised.
5 Architectural Revised Architectural Drawings � Vault / Arms Room 102
6 Civil Site Improvements scope of work.
7 Structural Revised Structural Drawings � Vault / Arms Room 102
7 ITEMS TOTAL
Item No. 1, RFI #001 reply.
Responses to RFI #001 submitted by Bidders are attached.
Item No. 2, Specifications Table of Contents revised.
The Table of Contents in the Specifications has been revised to indicate the removal of Section
10 22 13, Security Barriers (ABI #001). See Item No. 3, for additional information as applicable.
Item No. 3, Specification Section 10 22 13, Security Barriers (ABI #001) removed from project.
As indicated in RFI #001 reply, Section 10 22 13 has been removed from the project.
Specification Section 32 31 13 has been revised to provide additional information related to the
Addendum No. Two
BHA #202301
Scope of Work affected by removal of this Section. See Item No. 4, for additional information as applicable.
Item No. 4, Specification Section 32 31 13, Chain Link Fences & Gates (ABI #001) revised.
Specification Section 32 31 13 has been revised to clarify information related to the Scope of
Work of the chain link fencing to be provided on the project. Please note that this Scope of
Work remains as ABI #001.
Item No. 5, Revised Drawings � Vault / Arms Room 102.
The modular vault to be provided by the Owner has been removed from the project. In addition, the walls and ceiling around the Arms Room have been reinforced with an added layer of plywood and expanded wire mesh to increase their security level. Finally, Door 102 has been eliminated from the project. In its place, the Owner would like to install the existing vault door, identified during the pre-bid meeting and issued as part of Addendum Number 001, in this location. See revised drawing sheets attached with this Addendum.
Item No. 6, Site Improvements scope of work.
To assist in identification of the site improvements scope of work, A site improvements scope of work has been added to Sheet A100, Architectural Site Plan. See attached revised drawing for additional information.
Item No. 7, Revised Structural Drawings � Vault / Arms Room 102.
Structural drawings have been revised to reflect the removal of the modular vault from the project. In addition, the structural drawings have been revised to reflect the modifications to the metal framing around Arms Room 102 to increase security level of these walls. See revised drawing sheets attached with this Addendum.
END OF ADDENDUM NO. TWO
Encl: 1. RFI #001 responses dated 06/15/2023, RFIs received 06/13/2023
2. Specification Table of Contents (Revised 06/14/2023)
3. Specification Section 32 31 13, Chain Link Fences & Gates (ABI #001) (Revised 06/14/2023)
4. Revised Architectural drawings (Revised 06/15/2023):
Sheet LS100, Life Safety Plan
Sheet A101, Floor and Ceiling Plans
Sheet A401, Building Sections � Base Bid & ABI #002
Sheet A402, Wall Sections � Base Bid & ABI #002
Sheet A501, Interior Elevations, Schedules & Details
5. Revised Sheet A100, Architectural Site Plan (Revised 06/15/2023)
6. Revised Structural drawings (Revised 06/15/2023):
Sheet S001, General Notes & Design Criteria
Sheet S100, Foundation Plan
Sheet, S300, Framing Details (new Sheet)
RFI REPLY
Project: CBJTC Museum Warehouse Date: 06/15/2023 Camp Blanding Joint Training Center Comm. No.: 216041
To: All Bidding General Contractors Fax
U.S. Mail
Attn. Messenger
We are sending the following: Quick Ship
RFI No. Description Date Rec’d
001 General Clarifications 6/13/2023
1. Please confirm the primary and secondary are shop coated with Red Oxide primer.
Response: Primary steel shall be hot-dipped galvanized. Secondary steel shall be galvanized.
2. Please confirm Nucor is an acceptable Manufacturer.
Response: Nucor is an acceptable Metal Building manufacturer for the project.
3. Spec. 13 34 19-7, 2.4 Roof panels, Is 24 ga. acceptable or does it have to be 22 ga. 22 ga. is available with a 5,000
sf. minimum coil charge and extended lead time.
Response: 24-gauge roof panels are acceptable. Roof panels shall meet the wind design criteria as listed in the structural drawings and shall have a Florida Product Approval.
4. Spec. 13 34 19-7, 2.4.4 Roof panels call for a custom color Cardinal Red, is this correct? If so I will need a color code for pricing.
Response: Roof panel color shall be Sierra Tan.
5. Spec. 13 34 19-7, 2.5 Wall panels. Will the walls have to be a custom color?
Response: Wall panel color shall be Sierra Tan.
6. Spec. 13 34 19-7, 2.45 Roof and Walls. Is the basis of wind NOA n. 06-8090 or IBC 2018 as shown in the codes on sheet S001 in the bid drawings?
Response: Applicable Building Code for this project is 2020 Florida Building Code, not 2018 International
Building Code as listed on Sheet S001.
7. Spec. 13 34 19-7, 2.8. The roof and walls call for R-25 Simple saver and the bid drawings (sheet A402) are showing a 1.5� rigid board insulation to the outside of the steel line. Am I to supply an R-25 simple saver cavity insulation and a 1.5 rigid board insulation for the walls?
Response: Building insulation shall be as follows:
Roof: R-30 insulation system consisting of an R-19 blanket insulation with R-11 liner system. (Simple
Saver system or equal is acceptable.
Walls: 1.5� (R-6.5) continuous rigid insulation over R-13 vinyl wrapped blanket insulation. Please note that metal liner panels are required within the warehouse area from top of slab to 8�-0� a.f.f.
RFI REPLY
8. Both Section 10 22 13 & 32 31 13 pertain to the fence and alternate for this project. Both of which vary with requirements. Can you confirm which requirements we should be using when developing a proposal for this project?
Response: Section 10 22 13, Security Barriers (ABI #001) has been removed from the project. In addition, please see revised Section 32 31 13, Chain Link Fencing and Gates (ABI #001) for additional information and requirements for this Scope of Work.
9. The utility drawings provided show the sewer approx. 220 lf away from the new building restrooms. Are there additional utilities drawings that may identify the size and depth of existing sewer?
Response: The new sewer line will connect to the existing manhole, which from the top of the lid to bottom of the manhole is 7�. The existing manhole in question is located to the north of Avenue B and to the south of the project site., adjacent to road and to the south of the project site. See attached aerial photograph of the existing manhole location.
Copies to: With Attachments Transmittal Only Sent VIA
File X
By: Brian Sawyer, AIA LEED AP Bhide & Hall Architects, P.A.
1329 Kingsley Avenue, Suite C
Orange Park, Florida 32073
License #AAC000569
Phone: 904.264-1919
M a n h o l e
BSawyer Polygon
BSawyer Callout
PROJECT SITE
Table of Contents
CBJTC Museum Warehouse Building
202301
DIVISION 1 - GENERAL REQUIREMENTS
1 Non-Technical Specifications
01 10 00 Summary
01 30 00 Submittals
01 40 00 Quality Standards
01 70 00 Contract Closeout
01 78 46 Attic Stock
01 97 00 Alternate Bid Items (ABI’s)
DIVISION 3 - CONCRETE
03 10 00 Concrete Forming and Accessories
03 20 00 Concrete Reinforcing
03 30 00 Cast-In-Place Concrete
03 60 00 Grout (ABI #002)
DIVISION 4 - MASONRY
04 22 00 Concrete Masonry Unit Work (ABI #002)
04 23 00 Reinforced Unit Masonry (ABI #002)
04 72 00 Cast Stone Masonry (ABI #002)
DIVISION 5 - METALS
05 12 00 Structural Steel Framing
05 40 00 Metal Studs and Furring
DIVISION 6 - WOOD, PLASTICS & COMPOSITES
06 10 00 Carpentry
DIVISION 7 - THERMAL AND MOISTURE PROTECTION
07 11 00 Dampproofing (ABI #002)
07 60 00 Flashing and Sheet Metal
07 92 00 Sealants and Caulking
DIVISION 8 - OPENINGS
08 11 13 Hollow Metal Doors and Frames
08 31 16 Access Panels
08 33 23 Overhead Coiling Doors
08 71 00 Finish Hardware
DIVISION 9 - FINISHES
09 20 00 Gypsum Board
09 32 00 Rubber Base
09 65 19 Resilient Tile (Vinyl Composition Tile)
09 90 00 Painting
CBJTC Museum Warehouse Building
202301
DIVISION 10 - SPECIALTIES
10 22 13 Security Barriers (ABI #001)
10 28 13 Washroom Accessories
10 31 00 Exterior Signage
10 32 00 Interior Signage
10 42 00 Fire Extinguishers Cabinets
DIVISION 13 – SPECIAL CONSTRUCTION
13 34 19 Metal Building Systems
DIVISION 22 - PLUMBING
22 05 00 Plumbing
DIVISION 23 – HEATING, VENTILATION AND AIR CONDITIONING
23 05 00 Basic Mechanical Requirements
23 05 93 Testing, Adjusting and Balancing
23 07 00 Mechanical Insulation
23 22 15 Refrigerant Piping
23 22 16 Condensate Drain Piping
23 31 00 Ducts
23 33 00 Ductwork Accessories
23 37 00 Air Outlets and Inlets
23 81 26 Split System Air Conditioning Units (Heat Pumps)
DIVISION 26 -ELECTRICAL
26 03 05 Electrical General Requirements
26 05 19 Wire and Cable
26 05 26 Secondary Grounding
26 05 29 Supporting Devices
26 05 32 Conduit
26 05 33 Boxes
26 05 53 Electrical Identification
26 24 16 Panelboards
26 24 18 Motor Control
26 27 16 Cabinets and Enclosures
26 27 26 Wiring Devices
26 28 19 Disconnect Switches
26 51 10 LED Lighting Fixtures
DIVISION 28 -ELECTRONIC SAFETY AND SECURITY
28 31 00 Fire Alarm and Smoke Detection Systems
DIVISION 32 - EXTERIOR IMPROVEMENTS
32 31 13 Chain Link Fencing and Gates (ABI #001)
END OF TABLE OF CONTENTS
CHAIN LINK FENCING AND GATES 32 31 13
Project No. 216041 CBJTC Museum Warehouse Building
CFMO Project Number: 216041 BHA Project Number: 202301
32 31 13 - 1
SECTION 32 31 13
CHAIN LINK FENCING AND GATES
(ABI #001)
1. GENERAL
1.1. Purpose: Creation of secure fenced enclosures and/or partitions within Room 101, Warehouse Storage in the facility for the purpose of storage of sensitive museum artifacts.
1.2. Related Work: Section 10 22 13, Security Barriers
1.3. Submittal: Manufacturer’s data on all fencing materials, gate operators and components.
2. PRODUCTS
2.1. Chain Link Fabric: 9-gauge, 2” mesh,. 6’-0” height or width 8’-0” height as indicated on Drawings, galvanized.
2.2. Posts:
a. Line Posts: 2” schedule 40 steel pipe, galvanized.
b. Terminal and Corner Posts: 3” Schedule 40 steel pipe, galvanized.
c. Line posts to be 10’-0” o.c. maximum.
2.2.1 Rails: Top and Fence Rails: 1/1/2” schedule 40 steel pipe, galvanized.
Do not provide top or bottom rails. The Guard relies on tension wire top and bottom for security measures.
2.3. Tension Wire: 7 gauge, galvanized, continuous. Install through line posts at top and pass beside line posts at bottom.
2.4. Gates: Rigid welded frames, diagonally braced three hinges per leaf. All new gates shall be a single or pair of swing-type leaves, size as shown. Gate leafs shall be diagonal braced and shall clear floor 2” nominal.
2.7 Gate Hardware: Provide hinges and lockable hardware as required for proper operation of all gates and to properly secure all fenced areas.
CHAIN LINK FENCING AND GATES 32 31 13
Project No. 216041 CBJTC Museum Warehouse Building
CFMO Project Number: 216041 BHA Project Number: 202301
32 31 13 - 2
3. EXECUTION:
3.1. New fencing and gates: Provide new fencing and gates as shown. Provide terminal post at each end. Allow no more than 6” clearance between terminal post and adjacent construction to prevent someone from squeezing around terminal post.
3.2. Removal of debris: Contractor shall remove all fencing components left over at the completion of the project, and dispose of properly off-site.
3.3. Installation:
3.3.1. Install framework, fabric, and accessories in accordance with ASTM F567 and manufacturer’s instruction.
3.3.2. Set terminal and post plumb in concrete footings with top of footing 6 inches below finish grade. Embed posts minimum 2 feet into concrete. Set vertical supports plumb on concrete in galvanized sleeve bolted to floor.
3.3.3. Stretch fabric between posts or at intervals of 100 feet maximum, whichever is less.
3.3.4. Position bottom of fabric one inch above finished grade, with barbs up.
3.3.5. Fasten fabric to line posts, braces, and bottom tension wire with galvanized steel wire ties maximum 15 inches on center.
3.3.6. Fasten fabric to end and corner posts with tension bars and tension bar clips.
3.3.7. Install top and bottom tension wire stretched taut between terminal posts. Weave tension wires through the fabric.
3.3.8. Brace each gate and corner post to adjacent line post with horizontal center brace tail and diagonal truss rods. Install brace tail, on bay from end and gate posts.
3.3.9. Install each gate leaf with fabric fence. Install anti-crash gate retainer at both ends of gate and inverted dual-grooved metal track (nom. 1 ½” high). Install all gates in openings created for this purpose. Gate hinges to be rigidly connected to posts.
Lockable hardware to be installed at swing side of each gate leaf as required.
3.4. Erection Tolerances:
3.4.1. Maximum variation from plumb: 1/4 inch.
3.4.2. Maximum offset from true position: one inch.
END OF SECTION
MOST
REMOTE
POINT
84'-0"
TRAVEL DISTANCE
34"
34"
F
A
B
1 2 3 4 5 6
X X X X X X X X X X X X X X
X X
X
X
X
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
X X
X
X
X
X X
X X
X X
X
X X
X X
X X
X
X
X
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
X X
X X
X X
X X
X X
X X
X
X
X
X X
X
X
XX
X
X X
X X
X X
X
XFE
FE
A
B
F MOST
REMOTE
POINT
96'-0"
TRAVEL DISTANCE
A.1
A
A
B.1
C
B.1
B H
MECHANICAL /
ELECTRICAL
WAREHOUSE
SPACE
ARMS
ROOM
UNISEX
LATRINE
JANITOR
H
CHAIN LINK
FENCING AND
GATES
CHAIN LINK
FENCING AND
GATES
CHAIN LINK
FENCING AND
GATES
49'-10"
COMMON PATH OF TRAVEL
39'-9"
COMMON PATH OF TRAVEL
C.1
C.1
BUILDING ELEMENTS
PRIMARY STRUCTURAL FRAME
BEARING WALLS:
- EXTERIOR
- INTERIOR
NONBEARING WALLS & PARTITIONS:
- EXTERIOR ( > 30 FT. PROVIDED ALL SIDES)
- INTERIOR
FLOOR CONSTRUCTION
ROOF CONSTRUCTION, INCLUDING
SUPPORTING BEAMS & JOISTS
FBC TABLE 601
FIRE-RESISTANCE RATING REQUIREMENTS
FOR BUILDING ELEMENTS
TYPE IIB
0 HR
0 HR
0 HR
0 HR
0 HR
0 HR
0 HR
FIRE SEPARATION
DISTANCE
FBC TABLE 602
FIRE-RESISTANCE RATING REQUIREMENTS
FOR EXTERIOR WALLS
THIS PROJECT: TYPE IIIB CONSTRUCTION, GROUP S-1 OCCUPANCY,
GREATER THAN 30 FEET SEPARATION ALL SIDES
X < 5 FEET
5 FT. < X < 10 FT.
10 FT. < X < 30 FT.
X > 30 FT.
TYPE OF
CONSTRUCTION
ALL
TYPE III B
TYPE III B
ALL
OCCUPANCY
GROUP S-1
PROJECT CODE SUMMARY & INFORMATION:
DESCRIPTION:
NEW PRE-ENGINEERED METAL BUILDING FOR THE STORAGE OF CAMP BLANDING
MUSEUM PROPERTY. THE SINGLE-STORY STRUCTURE IS APPROXIMATELY 3,417
SQUARE FEET AND IS A NON-SPRINKLERED BUILDING.
CODE REFERENCES:
2020 FLORIDA BUILDING CODE (FBC)
2018 LIFE SAFETY CODE - NFPA 101:
CHAPTER 42, STORAGE OCCUPANCY
2020 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION
2020 FLORIDA FIRE PREVENTION CODE (FFPC)
2020 FLORIDA BUILDING CODE ENERGY EFFICIENCY
USE AND OCCUPANCY CLASSIFICATION:
FBC SECTION 302 & NFPA 101 - CHAPTER 6:
GROUP S-1, ORDINARY HAZARD STORAGE (FBC)
STORAGE, ORDINARY HAZARD (NFPA 101)
ALLOWABLE HEIGHT & STORIES ABOVE GRADE:
FBC TABLES 504.3a & 504.4:
BASED ON GROUP S-1 OCCUPANCY
MAX. # OF STORIES ACTUAL # OF STORIES
3 1
MAXIMUM BUILDING HEIGHT ACTUAL BUILDING HEIGHT
55' 19'-0"
ALLOWABLE BUILDING AREA:
FBC TABLE 506.2:
BASED ON GROUP S-1 OCCUPANCY
MAX. AREA ALLOWED ACTUAL AREA
17,500 SF PER STORY 3,417 SF
TYPE OF CONSTRUCTION - FBC CH. 6: TYPE IIIB
INTERIOR FINISHES CLASSIFICATIONS:
FBC TABLE 803.11:
GROUP S-1, NON-SPRINKLERED
INTERIOR EXIT STAIRWAYS, RAMPS, & PASSAGEWAYS: CLASS B
CORRIDORS AND ENCLOSURES FOR EXITS: CLASS B
ROOMS AND ENCLOSED SPACES: CLASS C
OCCUPANT LOAD:
FBC TABLE 1004.5, OCCUPANT LOAD:
WAREHOUSES 3,417 SF / 500 GSF PER OCCUPANT = 7 OCCUPANTS
NFPA 101 TABLE 7.3.1.2, OCCUPANT LOAD FACTOR:
STORAGE USE 3,417 SF / 500 GSF PER OCCUPANT = 7 OCCUPANTS
MEANS OF EGRESS SIZING:
FBC SECTION 1005:
EGRESS WIDTH REQUIRED: 7 OCCUPANTS AT 0.2" PER OCCUPANT = 1.4" (36" MIN.)
EGRESS WIDTH PROVIDED: 2 EXITS AT 34" PER EXIT = 68"
DEAD END CORRIDORS:
FBC SECTION 1020.4:
MAXIMUM LENGTH ALLOWED: 20 FEET
MAXIMUM LENGTH PROVIDED: NO DEAD ENDS PROVIDED
NFPA 101 TABLE 42.2.5:
MAXIMUM LENGTH ALLOWED: 50 FEET
MAXIMUM LENGTH PROVIDED: NO DEAD ENDS PROVIDED
COMMON PATH OF TRAVEL:
FBC TABLE 1006.2.1:
GROUP S-1, NON-SPRINKLERED (OL < 30)
MAXIMUM DISTANCE ALLOWED: 100 FEET
MAXIMUM DISTANCE PROVIDED: 49'-10"
NFPA 101 TABLE 42.2.5:
STORAGE USE, NON-SPRINKLERED
MAXIMUM DISTANCE ALLOWED: 50 FEET
MAXIMUM DISTANCE PROVIDED: 49'-10"
TRAVEL DISTANCE TO EXIT ACCESS:
FBC TABLE 1017.2:
GROUP S-1, NON-SPRINKLERED
MAXIMUM DISTANCE ALLOWED: 200 FEET
MAXIMUM DISTANCE PROVIDED: 96'-0"
NFPA 101 TABLE 42.2.6:
STORAGE USE, NON-SPRINKLERED
MAXIMUM DISTANCE ALLOWED: 200 FEET
MAXIMUM DISTANCE PROVIDED: 96'-0"
MINIMUM CORRIDOR WIDTH:
FBC SECTION 1020.2:
MINIMUM ALLOWED: 36 INCHES
WIDTH PROVIDED: NO CORRIDORS PROVIDED
MINIMUM NUMBER OF EXITS:
FBC 1006:
MINIMUM NUMBER REQUIRED: 2
NUMBER OF EXITS PROVIDED: 2
FIRE EXTINGUISHER LOCATIONS - NFPA 10:
FIRE EXTINGUISHERS TO BE LOCATED WITHIN 75 FT. TRAVEL DISTANCE. FIRE
EXTINGUISHER MOUNTING SHALL COMPLY WITH NFPA 10.
B
SCALE:
PARTITION THRU CEILING
4" METAL STUD
3/4" = 1'-0"
C
SCALE:
PARTITION THRU CEILING
6" METAL STUD
3/4" = 1'-0"
A
SCALE:
PARTITION TO STRUCTURE
4" METAL STUD
3/4" = 1'-0"
FLOOR FINISH & BASE AS
SCHEDULED EACH FACE
CONT. METAL STUD TRACK
CONT. METAL STUD
TRACK(PROVIDE BRACING TO
STRUCTURE AS REQUIRED
FOR RIGID CONDITION)
3 1/2" GLASS FIBER FRICTION
FIT ACOUSTICAL INSULATION.
EXTEND INSULATION FULL
HEIGHT OF STUDS
6" INCH METAL STUDS @ 24"
O.C. w/ (1) LAYER 5/8" GYP.
BD. EACH FACE
3/4" BACKING AND BLOCKING
FOR CABINETS, EQUIPMENT, &
FIXTURES. REFER TO PLANS
FOR LOCATIONS
FLOOR FINISH & BASE AS
SCHEDULED EACH FACE
CEILING AS
SCHEDULED
6" M
IN
CONT. METAL STUD TRACK
FLOOR FINISH & BASE AS
SCHEDULED EACH FACE
4" METAL STUDS
SPACED @ 24" O.C. w/ 3
1/2" THICK GLASS FIBER
BATT INSULATION
(1) LAYER 5/8" GYPSUM
EACH FACE
CONT. METAL STUD
TRACK
CEILING AS SCHEDULED
4" METAL STUDS SPACED
@ 24" O.C. w/ 3 1/2" THICK
GLASS FIBER BATT
INSULATION
(1) LAYER 5/8" GYPSUM
EACH FACE
PEMB
STRUCTURE
CEILING AS SCHEDULEDCEILING AS
SCHEDULED
6" M
IN
CONT. METAL STUD
TRACK(PROVIDE BRACING
TO STRUCTURE AS
REQUIRED FOR RIGID
CONDITION)
C.1
SCALE:
FURRING PARTITION
1-5/8" METAL STUD
3/4" = 1'-0"
FLOOR FINISH & BASE
AS SCHEDULED EACH
FACE
1-5/8" METAL STUDS
SPACED @ 24" O.C. w/
GLASS FIBER BATT
INSULATION
5/8" GYPSUM OVER
EXPANDED WIRE
MESH ON 1/2"
PLYWOOD
CONT. METAL STUD
TRACK
CEILING: SUSPENDED 5/8"
GYPSUM OVER
EXPANDED WIRE
MESH ON 1/2"
PLYWOOD
B.1
SCALE:
PARTITION TO STRUCTURE
6" METAL STUD
3/4" = 1'-0"
PEMB
STRUCTURE
A.1
SCALE:
PARTITION TO STRUCTURE
8" METAL STUD
3/4" = 1'-0"
EXTERIOR METAL
INSULATED WALL
PANEL
FLOOR FINISH & BASE
AS SCHEDULED EACH
FACE
8" METAL STUDS
SPACED @ 16" O.C. w/
GLASS FIBER BATT
INSULATION
5/8" GYPSUM OVER
EXPANDED WIRE MESH ON
1/2" PLYWOOD
CONT. METAL STUD
TRACK
PEMB
STRUCTURE
CEILING:
SUSPENDED 5/8" GYPSUM
OVER EXPANDED WIRE
MESH ON 1/2" PLYWOOD
5/8" GYPSUM ON
MTL. STUDS
INTERIOR OF
VAULT
CEILING:
SUSPENDED 5/8" GYPSUM
OVER EXPANDED WIRE
MESH ON 1/2" PLYWOOD
FLOOR FINISH & BASE
AS SCHEDULED EACH
FACE
8" METAL STUDS
SPACED @ 16" O.C. w/
GLASS FIBER BATT
INSULATION
5/8" GYPSUM OVER
EXPANDED WIRE MESH ON
1/2" PLYWOOD
CONT. METAL STUD
TRACK
INTERIOR OF
VAULT
INTERIOR OF
VAULT
'-0
FE
WALL MOUNTED FIRE EXTINGUISHER
MANUAL FIRE ALARM PULL STATION
EMERGENCY EXIT SIGN
AUDIO/VISUAL ALARM ( HORN / STROBE )H
F
LIFE SAFETY LEGEND
EMERGENCY LIGHT
TRAVEL DIST.
TRAVEL DISTANCE TO
AN EXIT
EMERGENCY EXIT SIGN WITH LIGHT
X DENOTES PARTITION WALL TYPE
LIFE SAFETY
PLAN
JKN
BS
LS100
SCALE:
LIFE SAFETY PLAN
LS100
1/4"= 1'-0"
D.B.
JOB NO.
C.B.
DATE
O R
A N
G E
P A
R K
F L
O R
ID
A
K
IN
G
S L
E Y
A V
E N
U E
S
U
IT
E C
L
IC
N
O
A A
C
P
H
(9
-1
F
L
S ta rk e, F
L
M U
S E
U M
W A
R E
H O
U S
E
C A
M P
B L
A N
D
IN
G J
O
IN
T
T R
A
IN
IN
G
C E
N T
E R
R E
V
IS
IO
N
S
04/28/2023
202301
Architect Brian
Sawyer AR0091953
License No.
AD
DE
ND
UM
/1
5/
A
B
1 2 3 4 5 6
FE
FE
A
B
1x4 PENDANT
MOUNTED LED LIGHT
FIXTURE, TYP. SEE
ELECTRICAL
DRAWINGS
1x4 PENDANT
MOUNTED LED
LIGHT FIXTURE, TYP.
EXPOSED STRUCTURE
ABOVE, TYP.
EXPOSED STRUCTURE
ABOVE, TYP.
WALL MOUNTED
LED LIGHT
FIXTURE, TYP.
SEE ELECTRICAL
DRAWINGS
PEMB STRUCTURE
ABOVE, TYP.
PEMB STRUCTURE
ABOVE, TYP.
PEMB STRUCTURE
ABOVE, TYP.
7'- 0"
EQ
UA
L
EQ
UA
L
4'-8"15'-8"
EXPOSED
STRUCTURE
ABOVE, TYP.
3'-4"6'-8"3'-4"
EQ
UA
L
EQ
UA
L
1x4 SUFRACE
MOUNTED LED
LIGHT FIXTURE, TYP.
1x4 SUFRACE MOUNTED LED LIGHT
FIXTURE, TYP. (CENTERED ON CEILING)
GWB CEILING ON SUSPENDED METAL
FRAMING
WALL MOUNTED
LED LIGHT
FIXTURE, TYP.
SEE ELECTRICAL
DRAWINGS
WALL MOUNTED LED
LIGHT FIXTURE, TYP. SEE
ELECTRICAL DRAWINGS
5'-6" 11'-0" 5'-6"7'- 4"
'-0
7'-
4"
MECHANICAL /
ELECTRICAL
WAREHOUSE
SPACE
ARMS
ROOM
UNISEX
LATRINE
JANITOR
GWB CLG.
EL: 10'-0"
GWB CLG.
EL: 10'-0"
GWB CLG.
EL: 10'-0"
1 1 A401 A401
A401
A401
D.S. D.S. D.S. D.S.
D.S. D.S. D.S. D.S.
WALL MOUNTED
LED LIGHT
FIXTURE, TYP.
SEE ELECTRICAL
DRAWINGS
WALL MOUNTED LED
LIGHT FIXTURE, TYP. SEE
ELECTRICAL DRAWINGS
WALL MOUNTED LED
LIGHT FIXTURE, TYP. SEE
ELECTRICAL DRAWINGS
5/8" GWB OVER
EXPANDED
METAL WIRE
MESH ON 1/2"
PLYWOOD ON
SUSPENDED
METAL FRAMING
A
B
1 2 3 4 5 6
X X X X X X X X X X X X X X
X X
X
X
X
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
X X
X
X
X
X X
X X
X X
X
X X
X X
X X
X
X
X
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
X X
X X
X X
X X
X X
X X
X
X
X
X X
X
X
XX
X
X X
X X
X X
X
XFE
FE
A
B
MECHANICAL /
ELECTRICAL
WAREHOUSE
SPACE
ARMS
ROOM
UNISEX
LATRINE
JANITOR
104 104
105 101B
101A
CHAIN LINK FENCE
AND GATES (ABI #001)
CHAIN LINK FENCE
AND GATES (ABI #001)
CHAIN LINK FENCE
AND GATES (ABI #001)
285 SF
ARMS VAULT
SHLV. (NIC)
WH
8' HIGH METAL LINER
PANEL, TYP. AT
WAREHOUSE SPACE
8' HIGH METAL LINER
PANEL, TYP. AT
WAREHOUSE SPACE
8' HIGH METAL LINER
PANEL, TYP. AT
WAREHOUSE SPACE
4" 3000psi CONCRETE
PAD, TYP.
SEE STRUCTURAL
DRAWINGS
4" 3000psi
CONCRETE
PAD, TYP.
6" PIPE
BOLLARD,
PAINT. SEE DET.
11/A501
6" PIPE BOLLARD,
PAINT. SEE DET.
11/A501
10'x10' OVERHEAD
COILING DOOR WITH
ELECT. OPERATOR
110'-0"
22'-0" 22'-0" 22'-0" 22'-0" 22'-0"
'-0
HVAC SPLIT-FACE CMU
VENEER WAINSCOT,
ABI #002
SPLIT-FACE CMU
VENEER WAINSCOT,
ABI #002
SPLIT-FACE CMU
VENEER WAINSCOT,
ABI #002
SPLIT-FACE
CMU VENEER
WAINSCOT,
ABI #002
WALL MOUNTED
LED LIGHT
FIXTURE ABOVE
WALL MOUNTED
LED LIGHT
FIXTURE ABOVE.
SEE ELECGRICAL
DRAWINGS
WALL MOUNTED LED LIGHT
FIXTURE ABOVE.
SEE ELECTRICAL DRAWINGS
8" 3" 13'-4" 7'-0" 9"
8" 3"
'-3
'-1 1"
3" 8"
8" 3"
19'-10 7/8" 1'-2 1/8"
8" 3"
5'- 3"
8'- 0"
4'-5" 6'-4" 12'-3" 3'-4"
3'- 4"
3'- 4"
3'- 4"
'-0
FD
A301
A301
A301
A301
1 1 A401 A401
A401
A401 5'- 0"
29'-4"
5'-0" 2'- 6"
'-0
D.S. D.S. D.S. D.S.
D.S. D.S. D.S. D.S.
EQ. EQ. EQ.
A.1
A
A
B.1
C
B.1
X
NOTE:
DENOTES PARTITION WALL TYPE. SEE
SHEET LS100 FOR MORE DETAILED
INFORMATION
DENOTES DOOR NUMBER. SEE SHEET A501
FOR DOOR SCHEDULE
XXX
B
FD
WALL MOUNTED LED
LIGHT FIXTURE, TYP. SEE
ELECTRICAL DRAWINGS
WALL MOUNTED
LED LIGHT
FIXTURE, TYP.
SEE ELECTRICAL
DRAWINGS
WALL MOUNTED LED
LIGHT FIXTURE, TYP. SEE
ELECTRICAL DRAWINGS
HOSE BIBB,
SEE PLUMBING
DRAWINGS
HOSE BIBB,
SEE PLUMBING
DRAWINGS
C.1
C.1
ARMS ROOM
VAULT DOOR
(EXISTING VAULT DOOR BY
OWNER - REPAIR AS
REQUIRED FOR PROPER
OPERATION, RESTORE
FINISH TO PAINT FINISH)
FLOOR
AND CEILING
PLANS
JKN
BS
A101
D.B.
JOB NO.
C.B.
DATE
O R
A N
G E
P A
R
O R
ID
A
K
IN
G
S L
E Y
A V
E N
U E
S
U
IT
E C
L
IC
N
O
A A
C
P
H
(9
-1
F
L
S ta rk e, F
L
M U
S E
U M
W A
R E
H O
U S
E
C A
M P
B L
A N
D
IN
G J
O
IN
T
T R
A
IN
IN
G
C E
N T
E R
R E
V
IS
IO
N
S
04/28/2023
202301
Architect Brian
Sawyer AR0091953
License No.
N O
RTH
SCALE:
FLOOR PLAN - PROPOSED
A101
1/4" = 1'-0"
SCALE:
REFLECTED CEILING PLAN - PROPOSED
A101
1/4" = 1'-0"
N O
RTH
AD
DE
ND
UM
/1
5/
EL. 0'-0"
T.O. SLAB
A402
5 4 2
NEW PENDANT LIGHT
FIXTURE MOUNTED TO
RIGID FRAME, TYP. - SEE
CEILING PLANS
STORAGE STORAGE
STORAGE
6 1.03
HI-LOW
WATER COOLER
CONCRETE
SLAB AND
FOOTINGS, SEE
STRUCTURAL
5/8" GWB ON 3-5/8"
MTL. FRAME
A402
'-0
A402
6'-6"
CLEAR
UNISEX
LATRINE
MECHANICAL/
ELECTRICAL
'-0
'-0
CHAIN LINK FENCING AND
GATES (ABI# 001)
A401
A401
EXISTING CONCRETE
SLAB, TO REMAIN
NEW SLAB OVER 10 MIL.
VAPOR BARRIER ON
COMPACTED FILL OR
SAND. SEE STRUCTURAL
DRAWINGS
'-0
'-0
B A
'-0
A402
A402
'-0
7'-7"
CLEAR
7'-0"
JANITOR
UNISEX
LATRINE
ARMS
ROOM AND VAULT
1'X4' SURFACE
MOUNTED LED LIGHT
FIXTURE, TYP.
A401
A401
EXISTING CONCRETE
SLAB, TO REMAIN
NEW SLAB . SEE
STRUCTURAL DRAWINGS
7'-0"
'-0
'-0
B A
'-0
A402
A401
'-0
7'-0"
JANITOR
UNISEX
LATRINE
1'X4' SURFACE
MOUNTED LED LIGHT
FIXTURE, TYP.
A401
A401
ARMS
ROOM AND VAULT
EXISTING CONCRETE
SLAB, TO REMAIN
NEW SLAB . SEE
STRUCTURAL DRAWINGS
5/8" GWB ON
3-5/8" MTL.
FRAME
5/8" GWB ON 1-5/8"
MTL. FRAME
JANITOR
PRE-ENGINEERED METAL STANDING
SEAM ROOF OVER PURLINS, BY
PRE-ENGINEERED METAL BUILDING
MANUFACTURER
CONTINUOUS
GUTTER SYSTEM
NOTE:
FOOTINGS AND SLAB ARE
SHOWN FOR GRAPHIC
PURPOSES ONLY. REFER TO
STRUCTURAL FOR NEW SLAB
AND FOOTING INFORMATION.
A
1'x4' SURFACE
MOUNTED LED
LIGHT FIXTURE,
TYP.
PRE-FINISHED PEMB
METAL WALL PANEL
CONT. 1-1/2" RIGID
INSULATION (R-7 MIN).
PEMB WALL GIRTS
CONCRETE SPLASH
BLOCK AT ALL
DOWNSPOUTS
4"x4" METAL
DOWNSPOUT
RIGID FRAME PER
PEMB SYSTEM
ROOF INSULATION
SYSTEM, SIMPLE
SAVER OR EQUAL
VINYL WRAPPED
BLANKET INSULATION
BY PEMB
MANUFACTURER
NEW CONCRETE SLAB OVER
10 MIL. VAPOR BARRIER ON
COMPACTED FILL OR SAND.
SEE STRUCTURAL DRAWNGS
EXISTING SLAB, TO
REMAIN
BUILDING
SECTIONS
BASE BID &
ABI #002
JKN
BS
A401
D.B.
JOB NO.
C.B.
DATE
O R
A N
G E
P A
R
O R
ID
A
K
IN
G
S L
E Y
A V
E N
U E
S
U
IT
E C
L
IC
N
O
A A
C
P
H
(9
-1
F
L
S ta rk e, F
L
M U
S E
U M
W A
R E
H O
U S
E
C A
M P
B L
A N
D
IN
G J
O
IN
T
T R
A
IN
IN
G
C E
N T
E R
R E
V
IS
IO
N
S
04/28/2023
202301
Architect Brian
Sawyer AR0091953
License No.
SCALE:
BUILDING SECTION (ABI #002)
A401
1/4"= 1'-0"
SCALE:
BUILDING SECTION - (ABI #002)
A401
1/4"= 1'-0" SCALE:
BUILDING SECTION - (BASE BID)
A401
1/4"= 1'-0"
SCALE:
WALL SECTION - (BASE BID)
A401
3/4"= 1'-0"
AD
DE
ND
UM
/1
5/
NOTE:
FOOTINGS AND SLAB ARE
SHOWN FOR GRAPHIC
PURPOSES ONLY. REFER TO
STRUCTURAL FOR NEW SLAB
AND FOOTING INFORMATION.
5/8" GWB ON
3-5/8" MTL.
FRAMING
UNISEX
LATRINE
1'x4' SURFACE
MOUNTED LED
LIGHT FIXTURE,
TYP.
'-0
NOTE:
SEE SHEET A501 FOR
INTERIOR ELEVATIONS
NEW CONCRETE SLAB
OVER 10 MIL. VAPOR
BARRIER ON COMPACTED
FILL OR SAND. SEE
STRUCTURAL DRAWINGS
PRE-ENGINEERED METAL STANDING
SEAM ROOF OVER PURLINS, BY
PRE-ENGINEERED METAL BUILDING
MANUFACTURER
EXISTING SLAB,
TO REMAIN.
RIGID INSULATION
SYSTEM, SIMPLE
SAVER OR EQUAL
A A201
ARMS
ROOM
5/8" GWB OVER
EXPANDED WIRE
MESH ON 12"
PLYWOOD OVER 6"
MTL. FRAMING
5/8" GWB OVER
EXPANDED WIRE
MESH ON 12"
PLYWOOD OVER
3-5/8"" MTL. FRAMING
PRE-ENGINEERED METAL STANDING
SEAM ROOF OVER PURLINS, BY
PRE-ENGINEERED METAL BUILDING
MANUFACTURER
PEMB WALL
GIRTS
PEMB METAL WALL
PANEL
NEW CONCRETE SLAB
OVER 10 MIL. VAPOR
BARRIER ON COMPACTED
FILL OR SAND. SEE
STRUCTURAL DRAWINGS
'-0
T.
O.
R
ID
GE
T.O.S 0' - 0"
CONCRETE FOOTING OVER
COMPACTED FILL
SEE STRUCTURAL
NOTE:
FOOTINGS AND SLAB ARE
SHOWN FOR GRAPHIC
PURPOSES ONLY. REFER TO
STRUCTURAL FOR NEW SLAB
AND FOOTING INFORMATION.
METAL LINER PANEL
OVER WALL GIRTS
PRE-CAST
CONCRETE COPING
(AB #002)
SPLIT FACE CMU
VENEER (ABI #002)
WAREHOUSE
SPACE
8'- 0"
EXISTING SLAB,
TO REMAIN.
VINYL WRAPPED
BLANKET INSULATION
BY PEMB
MANUFACTURER
A501
A501
C A201
RIGID INSULATION
SYSTEM, SIMPLE
SAVER OR EQUAL
1-1/2" CONT. RIGID
INSULATION (R-7. MIN)
'-0
PRE-ENGINEERED METAL STANDING
SEAM ROOF OVER PURLINS, BY
PRE-ENGINEERED METAL BUILDING
MANUFACTURER
5/8" GWB ON 3-5/8"
MTL. FRAME
CONCRETE FOOTING OVER
COMPACTED FILL
SEE STRUCTURAL
NOTE:
SEE SHEET A501 FOR
INTERIOR ELEVATIONS
HI-LOW ELECTRIC
WATER COOLER
UNISEX
LATRINE
5/8" GWB ON
3-5/8" MTL.
FRAME
NEW CONCRETE SLAB
OVER 10 MIL. VAPOR
BARRIER ON
COMPACTED FILL OR
SAND. SEE
STRUCTURAL
DRAWINGS
EXISTING SLAB,
TO REMAIN.
RIGID INSULATION
SYSTEM, SIMPLE
SAVER OR EQUAL
NOTE:
FOOTINGS AND SLAB ARE
SHOWN FOR GRAPHIC
PURPOSES ONLY. REFER TO
STRUCTURAL FOR NEW SLAB
AND FOOTING INFORMATION.
MECHANICAL/
ELECTRICAL
PRE-ENGINEERED METAL STANDING
SEAM ROOF OVER PURLINS, BY
PRE-ENGINEERED METAL BUILDING
MANUFACTURER
PEMB WALL GIRTS
PEMB METAL WALL
PANEL
'-0
T.
O.
R
ID
GE
PRE-CAST
CONCRETE COPING
(ABI #002)
SPLIT FACE CMU
VENEER (ABI #002)
8'- 0"
T.O FURRED
WALL
NEW CONCRETE SLAB
OVER 10 MIL. VAPOR
BARRIER ON COMPACTED
FILL OR SAND. SEE
STRUCTURAL DRAWINGS
EXISTING SLAB,
TO REMAIN.
VINYL WRAPPED
BLANKET INSULATION
BY PEMB
MANUFACTURER
RIGID INSULATION
SYSTEM, SIMPLE
SAVER OR EQUAL
A501
A501
C A201
1-1/2" CONT. RIGID
INSULATION (R-7. MIN)
5/8" GWB ON
3-5/8" MTL.
FRAME
5/8" GWB ON 1-5/8"
MTL. FRAME
JANITOR
PRE-ENGINEERED METAL STANDING
SEAM ROOF OVER PURLINS, BY
PRE-ENGINEERED METAL BUILDING
MANUFACTURER
PEMB WALL GIRTS
PEMB METAL WALL
PANEL
PRE-CAST
CONCRETE COPING
(ABI #002)
CONTINUOUS 6"x6"
METAL GUTTER
NOTE:
FOOTINGS AND SLAB ARE
SHOWN FOR GRAPHIC
PURPOSES ONLY. REFER TO
STRUCTURAL FOR NEW SLAB
AND FOOTING INFORMATION.
PRE-CAST
CONCRETE
SPLASH
BLOCK AT
EA.
DOWNSPOUT
SPLIT FACE CMU
VENEER (ABI #002)
4"x4" METAL
DOWNSPOUT
A
1'x4' SURFACE
MOUNTED LED
LIGHT FIXTURE,
TYP.
NEW CONCRETE SLAB
OVER 10 MIL. VAPOR
BARRIER ON COMPACTED
FILL OR SAND. SEE
STRUCTURAL DRAWINGS
EXISTING SLAB,
TO REMAIN.
VINYL WRAPPED
BLANKET INSULATION
BY PEMB
MANUFACTURER
RIGID INSULATION
SYSTEM, SIMPLE
SAVER OR EQUAL
A501
A501
1-1/2" CONT. RIGID
INSULATION (R-7. MIN)
B A201
WALL SECTIONS
BASE BID
AND
ABI #002
JKN
BS
A402
D.B.
JOB NO.
C.B.
DATE
O R
A N
G E
P A
R
O R
ID
A
K
IN
G
S L
E Y
A V
E N
U E
S
U
IT
E C
L
IC
N
O
A A
C
P
H
(9
-1
F
L
S ta rk e, F
L
M U
S E
U M
W A
R E
H O
U S
E
C A
M P
B L
A N
D
IN
G J
O
IN
T
T R
A
IN
IN
G
C E
N T
E R
R E
V
IS
IO
N
S
04/28/2023
202301
Architect Brian
Sawyer AR0091953
License No.
SCALE:
WALL SECTION - (ABI #002)
A402
3/4"= 1'-0" SCALE:
WALL SECTION
A402
3/4"= 1'-0" SCALE:
WALL SECTION - (ABI #002)
A402
3/4"= 1'-0" SCALE:
WALL SECTION
A402
3/4"= 1'-0" SCALE:
WALL SECTION - (ABI #002)
A402
3/4"= 1'-0"
AD
DE
ND
UM
/1
5/
MARK
REMARKSFLOOR BASE WALL
ROOM FINISH SCHEDULE
ROOM NAME QU
AR
RY
T
ILE
VI
NY
L C
OM
P
TI
LE
SE
AL
ED
C
ON
CR
ET
E
RU
BB
ER
NO
NE
(C
MU
QU
AR
RY
T
ILE
PA
IN
T
ON
C
MU
(A
BI
#0
PA
IN
T
ON
G
YP
B D
EP
OX
Y
PA
IN
T
ON
G
YP
. B
D
PE
MB
PA
IN
TE
D
GY
P
BD
ST
EE
L S
TR
. A
BO
VE
GY
P
BD
S
OF
FI
T
- - 1 2 3 4 5 6 7 8 9 10 11 12 13
CEILING
3 5
3 5
2 4 9
3 5 9
DOOR OPENING SIZEMA
RK
W H THK TY
PE
MA
T'L
FI
NI
SH
TY
PE
MA
T'L
FI
NI
SH
JA
MB
T'H
OL
D
HE
AD
HA
RD
W R
SE
T
UN
DE
RC
UT
GL
AZ
IN
G
RA
TI
NG
(H
R)
ROOM NAME
REMARKS
DOOR DETAILSFRAME
DOOR SCHEDULE
101 3'-0" 7'-0" 1 3/4" F HM1HM HM PT - - WAREHOUSE SPACE-
102 - - - - --
ON SHEET 1A11.1
ARMS ROOM
103 3'-0" 7'-0" HM UNISEX LATRINE1 3/4" - -1"
104 14'-0" 10'-0" 1 3/4" HM - --
105 3'-0" PAIR 7'-0" 1 3/4" HM - --
JANITOR
MECHANICAL/ ELECT.
WAREHOUSE SPACE
ARMS ROOM
UNISEX LATRINE
JANITOR
MECHANICAL/ ELECTRICAL
101A 10'-0" 10'-0" - OHC MTL - MTL FF
101B 3'-0" 7'-0" 1 3/4" HM PT - - WAREHOUSE SPACE-
5 8 12
HM
HM
HM
HM
3/A501 4&8/A501 7/A501
3/A501 7/A501
3/A501 4/A501 7/A501
1/A501 2/A501 -
SEE SPECS. FOR HARDWARE SET
SEE SPECS. FOR HARDWARE SET
SEE SPECS. FOR HARDWARE SET
SEE SPECS. FOR HARDWARE SET
SEE SPECS. FOR HARDWARE SET
WAREHOUSE SPACE
8/A501 9/A501 8/A501
5/A501 5/A501 6/A501 5/A501 5/A501 6/A501
HM - HOLOW METAL
MTL - METAL
PT - PAINT
FF - FACTORY FINISH
PT
PT
PT
PTPT
PT
PT
PT
PT
PT
5 10 PROVIDE METAL LINER PANEL TO 8'-0" A.F.F
SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION
F
F F F
HM1
HM1
HM1
HM2
4&8/A501
EXISTING REFURBISHED MTL MTL
DOOR AND FRAME
INTERIOR ELEVATIONS
1/4"=1'-0"SCALE:
1032 UNISEX LATRINE
TOILET ACCESSORY LEGEND
MARK DESCRIPTION NUMBER MANF. / REMARKS
GB-1 42" GRAB BAR B-6806 x 42 BOBRICK GB-2 36" GRAB BAR B-6806 x 36 BOBRICK M-1 24" x 36" MIRROR (H/C) B-165-2436 BOBRICK M-2 54" x 36" MIRROR B-165-5436 BOBRICK
PT-1 PAPER TOWEL DISPENSER B-262 BOBRICK
SD-1 SOAP DISPENSER B-2112 BOBRICK
TD-1 TOILET TISSUE DISPENSER B-2888 or B-386 BOBRICK
EWC ELECTRICAL WATER COOLER (SINGLE) EZS8L ELKAY
NOTE: MANUFACTURER/ MODEL NUMBER INFORMATION IS BASIS OF DESIGN. SEE SPECS
FOR ADDITIONAL INFORMATION AS APPLIES.
1031 UNISEX LATRINE
1'- 2"
1'-6"
2'-
3'- 4"
1'-5"
9'- 0"
SE
E
SC
HE
DU
LE
6"3'-6"
2'-
3'-0"
1'- 6" 2'-
PT-1
M-1
SD-1
H/C
GB-2GB-1
TP-1
GB-1
TP-1
1'- 6"
HM1
HOLLOW METAL
2" 2"
DR
O
PE
NI
NG
FRAME TYPES
SCALE: 1/4" = 1'-0"
F
FLUSH
2"
DR W.
OHC
OVERHEAD COILING
EXTERIOR
DOOR TYPES
SCALE: 1/4" = 1'-0"
10'-0"
'-0
2" 2"
DR
O
PE
NI
NG
2"
DR W.
(SINGLE LEAF)
HM2
HOLLOW METAL
(DOUBLE LEAF)
FR
AM
E
HE
IG
HT
JAMB OPENING
FRAME WIDTH
JA
M
B
OP
EN
IN
G
V
VAULT
PREF-FINISHED 'J'
TRIM
PRE-FINISHED METAL
WALL PANEL
DOOR AND FRAME,
AS SCHEDULED
PREF-FINISHED 'J'
TRIM
PRE-FINISHED
METAL WALL
PANEL LINER
WALL PANEL
CLOSURE STRIP
CONTINUOUS SEALANT AND
BACKER ROD (BOTH SIDES
OF DOOR FRAME)
PRE-FINISHED METAL
WALL PANEL
WALL PANEL
CLOSURE STRIP
PRE-FINISHED TRIM
WITH DRIP EDGE
CONTINUOUS SEALANT
AND BACKER ROD (BOTH
SIDES OF DOOR FRAME)
DOOR, AS SCHEDULED
PRE-FINISHED
METAL WALL
PANEL LINER
'C' GIRT
OVERHEAD COILING
DOOR ASSEMBLY
7/8"
2"
PREF-FINISHED 'J'
TRIM
PRE-FINISHED METAL
WALL PANEL
PRE-FINISHED
METAL WALL
PANEL LINER
WALL PANEL
CLOSURE STRIP
WEATHERSEAL
PRE-FINISHED
METAL WALL
PANEL
WALL PANEL
CLOSURE STRIP
WEATHERSEAL
OVERHEAD DOOR
W/ ELECTRIC
HOIST OPERATOR
SYSTEM
2"
FULLY GROUTED
CELL WITH
REINFORCING PER
STRUCT. DWGS.
CAULK AT
PERIMETER OF
FRAME (BOTH
SIDES)
HOLLOW METAL
FRAME - GROUT
SOLID, PAINT (ALIGN
WITH FACE OF CMU)
8" CMU WALL
HOLLOW METAL DOOR,
SEE SCHEDULE
(3) MASONRY
ANCHORS PER JAMB
IN FILLED CELL
PRE-FINISHED
METAL WALL
PANEL LINER
INTERIOR
SPLIT FACE CMU
VENEER
CAULK AT
PERIMETER OF
FRAME (BOTH
SIDES)
H.M. FRAME WITH 3
ANCHORS EACH
SIDE
3 5/8" U.O.N.
METAL STUDS WITH
5/8" GYP. BD. BOTH
SIDES CAULK ALL SIDES
TYPICAL AT INTERIOR STUD WALL
H.M. DOOR, SEE
SCHEDULE
H.M. FRAME
BEYOND, PAINT
DOOR, SEE
SCHEDULETHRESHOLD
FLOOR, SEE
SCHEDULE
INTERIOR
EXTERIOR H.M FRAME
CONCRETE SLAB
H.M DOOR
THRESHOLD
SET IN
SEALANT
18" DIA.
3'- 0"
4'- 0"
CONC. WASH
6" DIA. STEEL PIPE
(FILL SOLID W/
CONC.) (PAINTED)
CONC. PIER
FOOTING
6" CONC. SLAB (SEE
PLAN FOR INFO.)
4"x4" METAL DOWNSPOUT
PRE-CAST
CONCRETE
SPLASH BLOCK
4" SPLIT FACE BRICK W/
GALVANIZED TIES AT 16"
O.C (ABI #002)
WALL FLASHING
6"
FULLY GROUT
BELOW GRADE
10 MIL. VAPOR
BARRIER
FINISH GRADE
PEMB RIGID
FRAME
BEYOND
8" CMU WAINSCOT
W/ CELLS FULLY
GROUTED (ABI #002)
5/8" GWB ON
1-5/8" MTL.
FRAME
4"x4" METAL DOWNSPOUT
4" SPLIT FACE BRICK W/
GALVANIZED TIES AT 16"
O.C (ABI #002)
PRE-CAST CONCRETE
COPING (ABI #002)
8" CMU WAINSCOT
W/ CELLS FULLY
GROUTED (ABI #002)
5/8" GWB ON
1-5/8" MTL.
FRAME
VINYL
WRAPPED
BLANKET
INSULATION BY
PEMB MANUF.
'C' WALL GIRT
BY PEMB
MANUF.
1-1/2" CONT. RIGID
INSULATION (R-7, MIN)
PRE-FINISHED PEMB METAL
WALL PANEL
METAL CLOSURE PANEL BY
PEMB MANUF.
INTERIOR OF VAULT
ROOM
5/8" GWB OVER
EXPANDED WIRE
MESH
1/2" PLYWOOD OVER
8" METAL FRAME
METAL STUD
JAMB
FRAMING. SEE
STRUCTURAL.
5/8" GWB OVER 8"
METAL FRAME
EXISTING VAULT DOOR AND FRAME
INTERIOR OF VAULT
ROOM
METAL STUD HEAD
FRAMING, SEE
STRUCTURAL
5/8" GWB OVER 8"
METAL FRAME
5/8" GWB OVER
EXPANDED WIRE
MESH
1/2" PLYWOOD
OVER 8" METAL
FRAME
EX
IS
TI
NG
D
OO
R
AN
D
FR
AM
E
D.B.
JOB NO.
C.B.
DATE
O R
A N
G E
P A
R
O R
ID
A
K
IN
G
S L
E Y
A V
E N
U E
S
U
IT
E C
L
IC
N
O
A A
C
P
H
(9
-1
F
L
S ta rk e, F
L
M U
S E
U M
W A
R E
H O
U S
E
C A
M P
B L
A N
D
IN
G J
O
IN
T
T R
A
IN
IN
G
C E
N T
E R
R E
V
IS
IO
N
S
04/28/2023
202301
Architect Brian
Sawyer AR0091953
License No.
INTERIOR
ELEVATIONS
SCHEDULES AND
DETAILS
JKN
BS
A501
SCALE:
OHC HEAD DETAIL
A501
1-1/2" = 1'-0" SCALE:
OHC JAMB DETAIL
A501
1-1/2" = 1'-0"
SCALE:
H.M DOOR HEAD DETAIL
A501
1-1/2" = 1'-0" SCALE:
H.M DOOR JAMB DETAIL
A501
1-1/2" = 1'-0"
SCALE:
H.M DOOR JAMB DETAIL - (ABI #002)
A501
3" = 1'-0"
SCALE:
H.M DOOR HEAD/JAMB DETAIL
A501
1-1/2" = 1'-0"
SCALE:
INT. DOOR THRESHOLD
A501
1-1/2" = 1'-0"SCALE:
EXT. DOOR THRESHOLD
A501
1-1/2" = 1'-0"
SCALE:
BOLLARD
A501
3/8" = 1'-0"
SCALE:
H.M DOOR JAMB DETAIL - (ABI #002)
A501
1-1/2" = 1'-0"
SCALE:
H.M DOOR JAMB DETAIL - (ABI #002)
A501
1-1/2" = 1'-0"
SCALE:
VAULT DOOR SECTION
A501
1-1/2" = 1'-0" SCALE:
VAULT DOOR JAMB
A501
1-1/2" = 1'-0"
AD
DE
ND
UM
/1
5/
B
X
X
X
X
X
X
X
X
X
X
X
FE
FE
A
B
AVE. B
ST.
AUGUSTIN
E ST.
CAMP BLANDING
NEW MUSEUM
WAREHOUSE
EXISTING STORAGE
CONTAINERS,
TO REMAIN
SEE CIVIL
±27'-0"SEE CIVIL
±45 '-0"
ARCHITECTURAL
SITE PLAN
JKN
BS
A100
SCALE:
ARCHITECTURAL SITE PLAN
A100
1/32"=1'-0"
N O
R T
H
D.B.
JOB NO.
C.B.
DATE
O R
A N
G E
P A
R
O R
ID
A
K
IN
G
S L
E Y
A V
E N
U E
S
U
IT
E C
L
IC
N
O
A A
C
P
H
(9
-1
F
L
S ta rk e, F
L
M U
S E
U M
W A
R E
H O
U S
E
C A
M P
B L
A N
D
IN
G J
O
IN
T
T R
A
IN
IN
G
C E
N T
E R
R E
V
IS
IO
N
S
04/28/2023
202301
Architect Brian
Sawyer AR0091953
License No.
CIVIL CONSTRUCTION DRAWINGS ARE PENDING COMPLETION OF
SURVEY AND INFORMATION ON EXISTING UTILITIES. THE FOLLOWING
SITE RELATED SCOPE OF WORK SHOULD BE INCLUDED IN BID:
1. FURNISH AND INSTALL 500 LF OF SILT FENCE AROUND THE AREA OF
CONSTRUCTION.
2. DEMOLISH AND DISPOSE OF EXISTING FRAME BUILDING IN AREA OF WORK.
3. REMOVE AND DISPOSE OF TREE IN AREA OF WORK.
4. STRIP AREA WITHIN 20 FT OF NEW BUILDING.
5. DEMOLISH PORTIONS OF EXISTING CONCRETE SLAB AND CURBING REQUIRED FOR
CONSTRUCTION OF NEW FOUNDATIONS AND UTILITIES.
6. CAP/TERMINATE ANY ENCOUNTERED EXISTING UTILITY IN AN APPROVED MANNER.
7. OVER EXCAVATE ANY AREAS OF ORGANIC MATERIAL IN THE AREA OF PROPOSED
CONSTRUCTION .
8. REPLACE ANY OVER EXCAVATED AREAS AND BRING SITE TO GRADE WITH
IMPORTED STRUCTURAL FILL; STRUCTURAL FILL SHALL BE GRANULAR MATERIAL
COMPACTED IN MAXIMUM 6" LIFTS TO 98% ASTM D1557.
9. FURNISH AND INSTALL NEW 1" WATER SERVICE INCLUDING:
300 LF OF 1" HDPE DR9 PIPE BLUE COLOR WITH LOCATE WIRE
1" REDUCED PRESSURE BACKFLOW PREVENTER
1"X10" TAPPING SADDLE AND CURB STOP
10. FURNISH AND INSTALL NEW 6" GRAVITY SEWER SERVICE INCLUDING:
300 LF OF 6" PVC SDR26 GREEN COLOR WITH LOCATE WIRE. INSTALL PIPE PER
TYPE B BEDDING UNLESS SOIL CONDITIONS WARRANT TYPE A BEDDING AS
DETERMINED BY THE UTILITY INSPECTOR.
(3) CLEANOUTS
CORE AND CONNECTION INTO EXISTING MANHOLE
11. COMPACT ALL FOUNDATION AREAS; SUPPORTING SOIL SHALL EXHIBIT A MINIMUM
DENSITY OF 98% ASTM D1557 WITHIN A MINIMUM 12" DEPTH BELOW FOUNDATION
BEARING LEVEL.
12. FINAL GRADING OF SITE WITHIN 20 FT OF NEW BUILDING PER FINAL GRADING PLAN.
GRADE AROUND PERIMETER SHALL BE MINIMUM 8" BELOW FINISHED FLOOR; SITE
GRADING SHALL ENSURE POSITIVE DRAINAGE AWAY FROM BUILDING PERIMETER AT
MIN 2% FOR A MINIMUM OF 10 FT.
13. INSTALL CONCRETE SPLASH PADS AT GUTTER DOWNSPOUTS.
14. STABILIZE ALL DISTURBED AREAS WITH HYDROSEED.
15. AS-BUILT SURVEY PREPARATION OF ALL SITE AND UTILITY IMPROVEMENTS.
AD
DE
ND
UM
/1
5/
DESIGN PRESSURES FOR ROOF COMPONENTS & CLADDING (PSF)
10 SF
DESIGN PRESSURES FOR COMPONENTS & CLADDING NOTES:
1. PRESSURES LISTED ARE BASED ON ASCE 7-16.
2. PRESSURES LISTED ARE UNFACTORED (1.0W). MULTIPLY TABLE VALUES BY 0.6 FOR
ALLOWABLE STRESS (ASD) PRESSURES.
20 SF
50 SF
100 SF
200 SF
500 SF
EFFECTIVE
AREA (+) ALL (-)1(-)2e (-)2n(-)2r(-)3e (-)3r
ROOF ZONE
-67 -67 -43 -21 -21 -21
-98 -86 -79 -55 -40 -37
-116 -98 -79
-61 -61 -61
(+)4 (+)5
(-)4 -36 -34 -32 -31 -29 -27
(-)5 -44 -41 -37 -34 -31 -27
WALL ZONE
3' -0
3'-0"
3' -0
3'
-0
3' -0
3'-0"
2e
2e
2r
2r
3e
3e3e
3e
3r
2n
2n2n
2n
3r
5 54
NOT TO SCALE
WIND DESIGN PRESSURES FOR COMPONENTS & CLADDING DIAGRAM3
VICINITY MAP1
LOCATION MAP2
PROJECT ADDRESS:
5629 FLORIDA STATE ROAD - 16 W
STARKE, FLORIDA 32091
D.B.
JOB NO.
C.B.
DATE
O R
A N
G E
P A
R K
F
L O
R
ID
A
K
IN
G
SL
E Y
A V
E N
U E
, S U
IT
E
C L
IC
. N
O . A
A C
PH
4)
-1
F L
- 1
#3
St ar ke
, F L
M U
SE
U
M W
A R
E H
O U
SE
C
A M
P B
L A
N D
IN
G
J O
IN
T
T R
A
IN
IN
G
C E
N T
E R
R E
V
IS
IO
N
S
04/27/2023
202301
Engineer John P.
Grady, P.E., S.E 69322
License No.
ST
RU
CT
UR
ES
IN
TE
RN
AT
ION
AL
, L
LC
NO
T F
OR
CO
NS
TR
UC
TIO
N
B
ID
A
D D
E N
D U
M
/1 6/
1.0 ENGINEERING SCOPE:
1.0.1 THE SCOPE OF ENGINEERING FOR WHICH THIS ENGINEER OF RECORD (EOR) WAS IN
RESPONSIBLE CHARGE OF WAS LIMITED TO THE FOLLOWING:
A. FOUNDATION DESIGN FOR THE NEW PRE-ENGINEERED METAL BUILDING (PEMB).
B. INTERIOR LIGHT GAUGE FRAMED WALLS SHOWN ON SHEET S100.
1.0.2 THE SCOPE OF ENGINEERING FOR WHICH THIS EOR WAS IN RESPONSIBLE CHARGE
SPECIFICALLY EXCLUDES:
ANALYSIS OF SAFETY OF STRUCTURE DURING TEMPORARY CONSTRUCTION
STAGES.
DESIGN OF TEMPORARY SHORING AND OR BRACING.
ENGINEERING SCOPES OF WORK DELEGATED IN SECTION 1.1.
1.0.3 THE CONTRACTOR SHALL BRING TO THE ATTENTION OF THE EOR ANY STRUCTURAL
ENGINEERING SCOPES OF WORK NOT SPECIFICALLY ADDRESSED IN THE PROJECT
CONSTRUCTION DOCUMENTS PRIOR TO PROCUREMENT OF MATERIALS, FABRICATION
AND OR CONSTRUCTION.
1.1 DELEGATED ENGINEERING SCOPE:
THE SCOPE OF ENGINEERING FOR THIS PROJECT WHICH THE THE BUILDING EOR HAS DESIGNATED
AS A DELEGATED ENGINEERING SCOPE TO BE COMPLETED BY ANOTHER LICENSED ENGINEER
INCLUDES THE FOLLOWING:
1.1.1 PRE-ENGINEEERED METAL BUILDING SYSTEM.
1.2 GENERAL LIMITATIONS:
TO THE BEST OF THE EOR'S BELIEF AND KNOWLEDGE THESE DOCUMENTS HAVE BEEN PREPARED IN
ACCORDANCE WITH COMMONLY ACCEPTED STANDARDS OF CARE FOR CONSULTING STRUCTURAL
ENGINEERING, BUT IN NO WAY DO THEY CONSTITUTE A GUARANTEE OR WARRANTY OF ANY KIND.
1.3 NOTIFICATIONS TO THE OWNER:
1.3.1 STRUCTURE USE AND MODIFICATIONS:
THIS STRUCTURE HAS BEEN DESIGNED FOR THE ANTICIPATED LISTED STRUCTURAL
LOADINGS KNOWN AT THE TIME OF DESIGN AS LISTED IN THESE DRAWINGS. IT IS
INCUMBENT OF THE STRUCTURE OWNER TO ENGAGE THE SERVICES OF A STRUCTURAL
ENGINEER IN THE EVENT OF ANY PROPOSED CHANGE IN USE, CHANGE IN LOADING, NEW
CONCENTRATED LOADINGS, AND/OR WHEN MODIFICATIONS TO THE STRUCTURE ARE
PROPOSED.
1.3.2 STRUCTURE MAINTENANCE STATEMENT:
EVEN WHEN SUBJECTED TO ONLY REGULAR USE AND AGING, ALL STRUCTURES REQUIRE
PERIODIC INSPECTION AND MAINTENANCE TO ENSURE THE STRUCTURE IS MAINTAINED IN
A SAFE CONDITION FOR USE AND TO EXTEND THE LIFESPAN OF THE STRUCTURE. IT IS
INCUMBENT UPON THE OWNER TO ESTABLISH A PLANNED PROGRAM OF INSPECTION AND
MAINTENANCE. IN ESTABLISHING THIS PLAN ITEMS THAT SHOULD BE CONSIDERED
INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWING:
INSPECTION OF STRUCTURE FOR REGULAR USE AND AGING
INSPECTION OF DAMAGE (I.E. HIGH WINDS, SEISMIC, FLOOD, FIRE, IMPACT, EXPLOSIONS)
INSPECTION FOR EXPOSURE TO THE ENVIRONMENT (I.E. WATER, SALT)
INSPECTION FOR EXPOSURE TO HARSH CHEMICALS
INSPECTION FOR USE INVOLVING CYCLIC FATIGUE (I.E. STEEL CONNECTIONS & WELDS)
MAINTENANCE OF PROTECTIVE COATINGS AND SEALANTS
MAINTENANCE OF CONCRETE FOR CRACKS AND SPALLS
MAINTENANCE OF STEEL DUE TO CORROSION
MAINTENANCE OF STRUCTURE BY CLEANING FREE OF CHEMICALS
1.4 CONTRACTOR REQUIREMENTS:
1.4.1 SAFETY:
THE MEANS AND METHODS OF CONSTRUCTION IS THE FULL RESPONSIBILITY OF THE
CONTRACTOR. IT IS THE CONTRACTOR'S FULL RESPONSIBILITY TO BE FAMILIAR WITH
AND ADHERE TO ALL LOCAL, STATE, FEDERAL, AND INDUSTRY SAFETY
RECOMMENDATIONS AND REQUIREMENTS INCLUDING BUT NOT LIMITED THOSE OF OSHA,
FBC, AISC, & ACI.
1.4.2 TEMPORARY BRACING, SHORING, AND CONSTRUCTION STAGING:
TO THE BEST OF THE EOR'S BELIEF THESE DRAWINGS PROVIDE FOR A SAFE STRUCTURE
SUBJECT TO THE LISTED ANTICIPATED LOADING ONLY WHEN THE STRUCTURAL SYSTEMS
ARE FULLY COMPLETE AND CONSTRUCTED IN ACCORDANCE WITH THE CD'S. FULL
COMPLETION OF THE STRUCTURAL SYSTEMS INCLUDES BUT IS NOT LIMITED TO 100%
COMPLETION OF OF ALL FOUNDATIONS, WALLS, COLUMNS, FLOOR FRAMING, ROOF
FRAMING, PERMANENT BRACING, ROOF AND WALL SHEATHING OR DECKING, AND FULL
CURING OF ALL CONCRETE ELEMENTS.
THE SCOPE OF THESE ENGINEERING DOCUMENTS SPECIFICALLY EXCLUDES DESIGN AND
OR ANALYSIS OF THE SAFETY OF THE STRUCTURE FOR TEMPORARY CONSTRUCTION
LOADS AND OR DURING PARTIALLY COMPLETED CONSTRUCTION STAGES. THE DESIGN
OF TEMPORARY SHORING AND OR BRACING, CONSTRUCTION LIFTING AND ERECTION,
AND CONSTRUCTION STAGING AND SEQUENCING ARE THE FULL RESPONSIBILITY OF THE
GC. IT IS INCUMBENT ON THE GC TO IDENTIFY ADDITIONAL SCOPES OF ENGINEERING
REQUIRED FOR SAFE CONSTRUCTION OF THE STRUCTURE BASED ON THEIR PROPOSED
MEANS AND METHODS AND TO OBTAIN THE SERVICES OF A PROFESSIONAL ENGINEER AS
REQUIRED, AS WELL AS NOTIFY THE BUILDING EOR.
1.4.3 SUBMITTAL REQUIREMENTS:
THE FOLLOWING SUBMITTALS ARE REQUIRED TO BE REVIEWED AND APPROVED BY THE
EOR PRIOR TO CONSTRUCTION:
S01 CONCRETE MIX DESIGN
S02 FOUNDATION REINFORCING
S03 ANCHOR RODS
S04 MASONRY
S05 MASONRY GROUT & MORTAR
S06 MASONRY REINFORCING
S07 PRE-ENGINEERED METAL BUILDING (*)
ENGINEERED DRAWINGS AND CALCULATIONS, THAT ARE SIGNED AND SEALED BY A
PROFESSIONAL ENGINEER LICENSED IN THE STATE OF FLORIDA, ARE REQUIRED TO BE
INCLUDED IN SUBMITTALS MARKED (*).
1.4.4 INSPECTION AND TESTING REQUIREMENTS: REFER TO SHEET S0.002 AND MATERIAL
SECTIONS.
1.4.5 EXISTING CONDITIONS:
THE CONTRACTOR IS REMINDED THAT WORK ON THIS BUILDING REQUIRES WORKING
WITH AN EXISTING STRUCTURE. EVERY EFFORT HAS BEEN MADE TO IDENTIFY
DISCREPANCIES AND ENSURE THAT THE DETAILS ARE DEPICTED CORRECTLY. THESE
DRAWINGS HAVE BEEN PREPARED BASED ON INFORMATION AVAILABLE. HOWEVER,
SINCE THIS IS AN EXISTING STRUCTURE, THE CONTRACTOR CAN EXPECT AND SHOULD
PLAN ON ENCOUNTERING VARIANCES AND DEVIATIONS BETWEEN THE INFORMATION
FOUND IN THESE DRAWINGS AND THE EXISTING SITE CONDITIONS. ACTUAL FIELD
CONDITIONS MAY REQUIRE MODIFICATIONS IN CONSTRUCTION DETAILS AND QUANTITIES.
THE CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL DETAILS INCLUDING GEOMETRY
AND ELEVATIONS PRIOR TO THE FABRICATION AND INSTALLATION OF ANY MATERIAL.
1.5 CODES
THIS DESIGN HAS BEEN COMPLETED IN ACCORDANCE WITH THE FOLLOWING CODES :
2018 INTERNATIONAL BUILDING CODE
1.6 STRUCTURAL DESIGN LOADS & PARAMETERS:
1.6.1 RISK CATEGORY: II
1.6.2 WIND LOADS:
BASIC WIND SPEED (VULT): 125 MPH
EXPOSURE CATEGORY: C
INTERNAL PRESSURE COEFFICIENT (GCPI): ± 0.18 (ENCLOSED)
COMPONENTS AND CLADDING PRESSURES: SEE THIS SHEET
1.6.3 SEISMIC LOADS:
SEISMIC IMPORTANCE FACTOR (Ie): 1.0 SPECTRAL RESPONSE ACCELERATION (Ss): 0.087
SPECTRAL RESPONSE ACCELERATION (S1): 0.049
SPECTRAL RESPONSE MODIFICATION (SDS): 0.092
SPECTRAL RESPONSE MODIFICATION (SD1): 0.078
SEISMIC DESIGN CATEGORY: B
SEISMIC RESISTING SYSTEM: STEEL SYSTEMS NOT
SPECIFICALLY DETAILED
RESPONSE MODIFICATION FACTOR (R): 3.0
OVERSTRENGTH FACTOR (Ωo): 3.0 DEFLECTION MODIFICATION FACTOR (Cd): 3.0
2.0 SOILS INFORMATION:
2.0.1 FOUNDATIONS WERE DESIGNED FOR A NET ALLOWABLE SOILS BEARING CAPACITY OF
2,000 PSF.
2.0.2 IT IS THE CONTRACTOR'S FULL RESPONSIBILITY TO ENSURE THAT BACKFILL IS
WELL-DRAINED SANDY MATERIAL, FREE FROM ORGANIC MATERIALS AND HAVING AN
ANGLE OF INTERNAL FRICTION (Φ) OF 30 DEGREES AND A MOIST DENSITY OF 120 PCF.
2.0.3 THE GENERAL CONTARCTOR IS RESPONSIBLE TO EMPLOY AN INDEPENDENT QUALIFIED
TESTING LABORATORY TO INSPECT EARTHWORK OPERATION AND TEST COMPACTED
SOILS TO ENSURE AND CERTIFY THAT THE SOILS SUPPORTING FOOTINGS AND SLABS
ARE ADEQUATE TO ACHIEVE THE NET ALLOWABLE SOIL BEARING CAPACITY PRESUMED.
3.0 CONCRETE:
3.0.1 ALL STRUCTURAL CONCRETE MUST BE NORMAL WEIGHT WITH A 28 DAY MINIMUM
COMPRESSIVE STRENGTH OF 4000 PSI WITH MAXIMUM AGGREGATE SIZE OF 3/4".
3.0.2 REINFORCING STEEL MUST BE ASTM A615, GRADE 60. ALL LAP SPLICES SHALL BE A
MINIMUM OF 48 BAR DIAMETERS UNLESS OTHERWISE NOTED.
3.0.3 WELDED WIRE REINFORCING MUST BE ASTM A1064. LAPS SHALL BE A MINIMUM OF 6
INCHES.
3.0.4 UNLESS OTHERWISE SHOWN ON DRAWINGS, COVER FOR REINFORCING WILL BE:
CONCRETE NOT EXPOSED TO EARTH OR WEATHER:
SLABS AND WALLS:
#11 BARS AND SMALLER 1 INCHES
BEAMS AND COLUMNS:
PRIMARY REINFORCING, TIES & STIRRUPS 2 INCHES
ELEVATED SLABS: CENTERED
3.0.5 A CERTIFIED TESTING AGENCY MUST BE ENGAGED TO PERFORM INDUSTRY STANDARD
TESTING INCLUDING SLUMP TESTS AND COMPRESSIVE TESTS (CYLINDER BREAKS) TO
ENSURE CONFORMANCE WITH THE PLANS AND SPECIFICATIONS. SUBMIT ALL TEST
REPORTS FOR REVIEW AND APPROVAL.
3.0.6 THE MINIMUM FREQUENCY OF TESTING FOR EACH CLASS OF CONCRETE IS THE
GREATEST OF:
A. ONCE EACH DAY
B. ONCE FOR EACH 100 CY
C. ONCE FOR EACH 5,000 SF OF SLAB OR WALL SURFACE AREA
D. FIVE (5) TESTS
3.0.7 ALL REINFORCING MUST BE HELD SECURLY IN POSITION WITH STANDARD ACCESSORIES
IN CONFORMANCE WITH ACI 315 DURING PLACEMENT OF CONCRETE.
3.0.8 ALL REINFORCING SPLICES MUST BE APPROVED BY THE EOR. SPLICES IN TOP
REINFORCING MUST BE MADE AT MIDSPAN OF MEMBERS AND SPLICES IN BOTTOM
REINFORCING MUST BE MADE OVER SUPPORTS.
3.0.9 TOP BARS SHALL TERMINATE IN ACI STANDARD HOOKS AT DISCONTINUOUS ENDS
UNLESS OTHERWISE NOTED.
3.0.10 PROVIDE A 3/4 INCH CHAMFER ALONG ALL EXPOSED CORNERS OF BEAMS AND
COLUMNS. CHAMFER IS NOT REQUIRED WHERE BEAMS ARE CAST INTEGRALLY WITH
WALLS.
3.0.11 PROVIDE 1/2 INCH THICK PREFORMED EXPANSION JOINT MATERIAL WHERE SLABS
ABUT COLUMNS, WALLS, AND OTHER VERTICAL SURFACES UNLESS OTHERWISE NOTED.
4.0 CONCRETE MASONRY:
4.0.1 ALL CONSTRUCTION MUST BE IN CONFORMANCE WITH MSJC TMS 402-16 / ACI 530-16 /
ASCE 5-16.
4.0.2 CONCRETE MASONRY MATERIALS MUST MEET THE FOLLOWING:
CONCRETE BLOCK ASTM C90, F'M = 1900 PSI
MORTAR ASTM C270, TYPE "S"
GROUT ASTM C476, F'C = 3000 PSI
QUIKCRETE COREFILL FINE
REINFORCING ASTM A615, GRADE 60
JOINT REINFORCING ASTM A951, LADDER TYPE (MIN 9GA WIRES)
THREADED MECHANICAL HEADS TERMINATOR D14 BY NVENT / LENTON
4.0.3 ALL GROUT SHALL BE A SHRINKAGE COMPENSATING, PRE-MIXED TYPE CONSISTING OF
NON-METALLIC AGGREGATE WITH A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT
28 DAYS AND A SLUMP OF 8" TO 11" WITH 3/8" MAX AGGREGATE.
4.0.4 BLOCK SHALL NOT BE MOISTENED BEFORE GROUTING.
4.0.5 ALL MASONRY CROSS WEBS SHALL BE FULLY BEDDED IN MORTAR AROUND CELLS TO
BE GROUTED.
4.0.6 GROUT PLACEMENT STOPPED FOR (1) HOUR OR MORE SHOULD BE STOPPED 1.5" BELOW
THE TOP OF THE MASONRY UNIT TO PROVIDE A KEY FOR SUBSEQUENT GROUTING.
4.0.7 UNIFORM LOADS ARE NOT TO BE APPLIED TO MASONRY WALLS FOR (3) DAYS.
CONCENTRATED LOADS ARE NOT TO BE APPLIED TO MASONRY WALLS FOR (7) DAYS.
4.0.8 VERTICAL REINFORCING MUST HAVE A MINIMUM CLEARANCE OF 3.5" TO INSIDE FACE OF
FACE SHELL.
4.0.9 VERTICAL REINFORCING IN WALLS SHALL BE SECURED AND LATERALLY SUPPORTED
AGAINST DISPLACEMENT AT INTERVALS NOT EXCEEDING 192X(BAR DIAMETER) OR 10 FT
(WHICHEVER IS LESS).
4.0.10 TYPICAL VERTICAL REINFORCING SIZE AND SPACING SHALL BE ABOVE AND BELOW ALL
WALL OPENINGS.
4.0.11 EXTEND ALL VERTICAL WALL REINFORCEMENT TO WITHIN 2" OF TOP OF WALL OR BEAM
UNLESS NOTED OTHERWISE. TERMINATE REINFORCING WITH STANDARD ACI 90 DEGREE
HOOK.
4.0.12 TEMPORARY SHORING FOR ALL EXTERIOR MASONRY WALLS SHALL REMAIN IN PLACE &
CONNECTED ELIMINATING CANTILEVER ACTION OF THE WALLS UNTIL FINAL
CONNECTIONS ARE COMPLETED.
S001
5.0 STRUCTURAL STEEL:
5.0.1 ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH AISC 360-16 & AISI 100-16.
5.0.2 STRUCTURAL STEEL MATERIALS MUST MEET THE FOLLOWING:
ANCHOR RODS ASTM F1554, GRADE 36
WASHERS ASTM AF436
NUTS ASTM F563, GR. A "HEX"
5.1 LIGHT GAUGE METAL FRAMING:
5.1.1 ALL STRUCTURAL MEMBERS SHALL BE DESIGNED IN ACCORDANCE WITH AMERICAN IRON
AND STEEL INSTITUTE, "SPECIFICATION FOR THE DESIGN OF COLD FORMED
STRUCTURAL MEMBERS, 2016 EDITION.
5.1.2 ALL STRUCTURAL STUDS AND JOISTS OF 18 AND 20 GAUGES SHALL BE FORMED FROM
GALVANIZED STEEL PER ASTM A653, G60 COATING MEETING THE REQUIREMENTS OF
ASTM C955 WITH A YIELD STRENGTH OF 33,000 PSI.
5.1.3 ALL STRUCTURAL STUDS AND JOISTS OF 16, 14 AND 12 GAUGES SHALL BE FORMED FROM
GALV…