20260730_GPS_CC_Fire Alarm Upgrades_CDs.pdf
PDF 2 MB Posted
- Attached to
- Fire Alarm Upgrades
- Solicitation number
- RFP GRPS 270000000035 1
- Issued by
- Macomb County, Michigan
About this file
This is a construction document set consisting of electrical design plans and specifications for fire alarm system upgrades at Cedar Crest Elementary School in Greenville, Michigan, prepared by Kingscott Associates Inc. for Greenville Public Schools. The project involves complete replacement of the building's fire alarm system with a new voice-capable, addressable system that provides both manual and automatic alarm initiation. The scope includes installation of smoke detectors, heat detectors, fire alarm pull stations, audible and visual notification appliances (speakers and strobes), duct detectors, door hold-open devices, magnetic door holders, and a fire alarm control panel. The construction documents reference three building units (A, B, and C) with separate electrical demolition and power plans for each unit. The plans indicate coordination with mechanical systems, including integration with existing kitchen hood fire suppression systems and duct smoke damper controls. Shop drawings are required for conduit, conductors, wiring devices, panelboards, transformers, surge protection devices, lighting fixtures, and the complete fire alarm system.
The construction documents, dated July 30, 2026, are issued as final construction documents and include detailed electrical symbols, abbreviation lists, general electrical notes, and specific installation requirements per the National Electrical Code and NFPA 72 standards. The work requires coordination with Consumers Energy for electrical service provisions and compliance with the Michigan Electrical Code. All work must include proper permitting and inspections, removal of abandoned electrical equipment, patch and repair of openings, and installation of lamacoid labels on equipment. The electrical contractor must provide a fully functional fire alarm system with dedicated 120-volt circuits from the main distribution panel, conduit sizing of minimum 1/2-inch trade size, and proper grounding per NEC standards. Construction management is provided by Fritz Wahlfield Construction, with MEP engineering by Ignyte Design, both based in Michigan.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 20260730_GPS_BH_Fire Alarm Upgrades_CDs.pdf | ||
| GPS_Fire Alarm Upgrades_Specifications.pdf | ||
| 20260730_GPS_WH_Fire Alarm Upgrades_CDs.pdf | ||
| FRONT ENDS.pdf | ||
| BID INVITE.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NO. NAME
GENERAL
G0.1 TITLE SHEET
ELECTRICAL
E000 ELECTRICAL SYMBOLS AND GENERAL NOTES
ED110A FIRST FLOOR ELECTRICAL DEMOLITION PLAN - UNIT A
ED110B FIRST FLOOR ELECTRICAL DEMOLITION PLAN - UNIT B
ED110C FIRST FLOOR ELECTRICAL DEMOLITION PLAN - UNIT C
E110 OVERALL FIRST FLOOR POWER PLAN
E110A FIRST FLOOR POWER PLAN UNIT A
E110B FIRST FLOOR POWER PLAN UNIT B
E110C FIRST FLOOR POWER PLAN UNIT C
KINGSCOTT ASSOCIATES INC. PORTAGE, MICHIGANCC
JOB NO.
SHEET TITLE
SHEET NO.
ISSUANCES DATE
P L
E A
S E
R E
C Y
C L
E
T H
E S
E D
R A
W
IN
G S
A N
D T
H E
W O
R K
R E
P R
E S
E N
T E
D T
H E
R E
IN
A
R E
T H
E P
R O
P E
R T
Y O
F A
N D
C
O P
Y R
IG
H
T
K
IN
G
S C
O T
T A
S S
O C
IA
T
E S
A
D
M A
Y N
O T
B E
U S
E D
O R
R E
P R
O D
U C
W
IT
H
O U
T P
E R
M
IS
S
IO
N
L A
S T
P R
IN
T
E D ljh
PORTAGE | CHELSEA | GRAND RAPIDS | DETROIT
/3
/2
:2
:1
P
M
Z
P ro je c ts
\G re e n v ill e P u b lic
S c h o o ls
\0
S in k in g F u n d P ro je c ts
\0 B
C e d a r
C re s t
E le m e n ta ry \D
R A
W
IN
G S
\3 A rc h \R
E V
IT
\G
P S
C e d a r
C re s t
E le m e n ta ry A rc h r2
-t it le b lo c k o n ly
.r v t
3197.04B1
TITLE SHEET
G0.1
M ap le S tre et
G re en vi lle , M
I 4
G re e nv ill e P ub lic
S ch o o ls
C e d a r C re st
Fi re A la rm
U p d a te s
-B P
Greenville Public Schools
Cedar Crest - Fire Alarm Updates - BP03
SHEET INDEX:
CONSTRUCTION DOCUMENTS
July 30, 2026
CLIENT:
GREENVILLE PUBLIC SCHOOLS
1414 CHASE STREET
GREENVILLE, MI 48838
P. (616) 754-3686
ARCHITECT:
KINGSCOTT ASSOCIATES INC.
950 TRADE CENTRE WAY, SUITE 130
PORTAGE, MI 49002
P. (800) 632-7815
CONSTRUCTION MANAGER:
DIRECTORY
FRITZ WAHLFIELD CONSTRUCTION
4455 WESTSHIRE DR
COMSTOCK PARK, MI 49321
P. (616) 784-5833
MEP ENGINEER
IGNYTE DESIGN
38 COMMERCE AVENUE SW
SUITE 450
GRAND RAPIDS, MI 49503
P. (616) 550-5411
CONSTRUCTION DOCUMENTS 07.30.2026
ELECTRICAL ABBREVIATION LIST
ABBREVIATION DESCRIPTION
A
AF
AFCI
A.F.F.
AIC
AL
AR
AT
ATS
AUX
BKR
BPS
C
CB
CKT
CT
DEMO
DIM
DISC
DP
DS
DWG
EBU
EC
ELEC
EM/ EMERG
EMT
EO
EPO
EWC
EXIST
EXT
FA
FLA
FLR
FOH
FSEC
FU
G/GRD/EG
GFCI
GFP
HOA
HP
HV
HZ
IG
JB
KV
KVA
KW
KWH
LA
LP
LDP
AMPERES
AMPERES FRAME (BREAKER RATING)
ARC FAULT CIRCUIT INTERRUPTER
ABOVE FINISH FLOOR
AMPS INTERRUPTING CAPACITY
AUDIENCE LEFT
AUDIENCE RIGHT
AMPERS TRIP (BREAKER SETTING)
AUTOMATIC TRANSFER SWITCH
AUXILIARY
BREAKER
BOLTED PRESSURE SWITCH
CONDUIT
CIRCUIT BREAKER
CIRCUIT
CURRENT TRANSFORMER
DEMOLITION
DIMENSION
DISCONNECT
DISTRIBUTION PANEL
DOWNSTAGE
DRAWING
EMERGENCY BATTERY UNIT
ELECTRICAL CONTRACTOR
ELECTRICAL
EMERGENCY
ELECTRICAL METALLIC TUBING
ELECTRICALY OPERATED
EMERGENCY POWER OFF
ELECTRIC WATER COOLER
EXISTING
EXTERIOR
FIRE ALARM
FULL LOAD AMPS
FLOOR
FRONT OF HOUSE
FOOD SERVICE EQUIPMENT
FUSE
GROUND
GROUND FAULT CIRCUIT INTERRUPTER
GROUND FAULT PROTECTION
HAND-OFF-AUTO
HORSEPOWER
HIGH VOLTAGE
HERTZ
ISOLATED GROUND
JUNCTION BOX
KILOVOLT
KILOVOLT - AMPERES
KILOWATT
KILOWATT - HOURS
LIGHTING ARRESTOR
LIGHTING PANEL
LIGHTING DISTRIBUTION PANEL
MAX
MCB
MCC
MDP
MECH
MIN
MISC.
MLO
MTD
MTG
MTR
N
NC
NEC
NF
NIC
NL
NO
NTS
OC
OFCI
OFOI
P
PB
PH
PT
PDP
RECEPT.
RCP
RDP
RP
RSC
SCHED
SW
SWBD
SWGR
TB
TELECOM
TR
TTP
TYP
UNO
US
V
W
WG
WP
XFMR
XP
(E)
(R)
MAXIMUM
MAIN CIRCUIT BREAKER
MOTOR CONTROL CENTER
MAIN DISTRIBUTION PANEL
MECHANICAL
MINIMUM
MISCELLANEOUS
MAIN LUGS ONLY
MOUNTED
MOUNTING
MOTOR
NEUTRAL
NORMALLY CLOSED
NATIONAL ELECTRICAL CODE
NON-FUSIBLE
NOT IN CONTRACT
NIGHT LIGHT
NORMALLY OPEN
NOT TO SCALE
ON CENTER
OWNER FURNISHED,
CONTRACTOR INSTALLED
OWNER FURNISHED,
OWNER INSTALLED
POLE
PUSHBUTTON STATION
PHASE
POTENTIAL TRANSFORMER
POWER DISTRIBUTION PANEL
RECEPTACLE
RECEPTACLE
RECEPTACLE DISTRIBUTION PANEL
RECEPTACLE PANEL
RIGID STEEL CONDUIT
SCHEDULE
SWITCH
SWITCHBOARD
SWITCHGEAR
TERMINAL BOX
TELECOMMUNICATIONS
TAMPER RESISTANT
TELEPHONE TERMINAL BACKBOARD
TYPICAL
UNLESS OTHERWISE NOTED
UPSTAGE
VOLTS
WIRE OR WATTS
WIRE GUARD
WEATHERPROOF
TRANSFORMER
EXPLOSION PROOF
EXISTING
RELOCATED
ELECTRICAL SYMBOL LIST
SYMBOL DESCRIPTION
LIGHTING FIXTURE - ARCHITECTURAL TROFFER
EMERGENCY LIGHTING FIXTURE
LIGHTING FIXTURE - PENDANT
WALL MOUNTED LIGHTING FIXTURE
LIGHTING FIXTURE
LIGHTING TRACK OR ROPE LIGHT
TRACK LIGHTING FIXTURE
EMERGENCY LIGHTING UNIT
POLE MOUNTED LIGHTING FIXTURE
POLE MOUNTED LIGHTING FIXTURE - POST TOP
BOLLARD LIGHTING FIXTURE
EXIT LIGHTING FIXTURE WITH DIRECTIONAL
ARROWS (SHADED AREA INDICATES FACE)
EXIT LIGHTING FIXTURE WITH DIRECTIONAL
ARROWS (SHADED AREA INDICATES FACE)
EXIT LIGHTING FIXTURE - WALL MOUNTED
SINGLE POLE TOGGLE SWITCH
TWO POLE TOGGLE SWITCH
3 WAY TOGGLE SWITCH
4 WAY TOGGLE SWITCH
KEY OPERATED SWITCH
DIMMER SWITCH
PILOT SWITCH
OCCUPANCY SENSOR DEVICE - CEILING
SIMPLEX / DUPLEX RECEPTACLE
SIMPLEX / DUPLEX RECEPTACLE CONTROLLED BY
AUTOMATIC CONTROL DEVICE / SYSTEM
QUAD RECEPTACLE
ABOVE COUNTER DUPLEX RECEPTACLE (SIMILAR FOR
TAMPER RESISTANT, QUADS, EMERGENCY AND GFI
RECEPTACLES)
DUPLEX RECEPTACLE-GROUND FAULT CIRCUIT
INTERRUPTER
DUPLEX EMERGENCY RECEPTACLE
CEILING MOUNTED
DUPLEX RECEPTACLE
SPECIAL RECEPTACLE - REFER TO ELECTRICAL
STANDARD SCHEDULES
MULTI-OUTLET RACEWAY - LEGRAND AL3300 OR EQUAL
POKE-THROUGH ASSEMBLY - LEGRAND
EVOLUTION SERIES OR EQUAL
SYMBOL DESCRIPTION SYMBOL DESCRIPTION
CONTROL PANEL
VARIABLE FREQUENCY DRIVE
MOTOR
MANUAL CONTROLLER
MAGNETIC CONTROLLER
COMBINATION MAGNETIC CONTROLLER
NON-FUSIBLE DISCONNECT SWITCH
FUSIBLE DISCONNECT SWITCH
ENCLOSED CIRCUIT BREAKER
PUSH BUTTON STATION
AUTOMATIC DOOR CONTROLLER
AUTOMATIC DOOR PUSH PAD OPERATOR
GROUND ROD
GROUND CONNECTION
CONDUIT SLEEVE WITH BUSHINGS
LENGTH AS REQUIRED
"X" INDICATES CONDUIT SIZE
CONDUIT STUB - UP/DOWN
EMPTY BOX FOR FUTURE
TELECOMMUNICATION OUTLET
EMPTY BOX FOR FUTURE TELECOMMUNICATION
OUTLET MOUNTED 4" ABOVE COUNTERTOP
EMPTY BOX FOR FUTURE CEILING MOUNTED
TELECOMMUNICATION OUTLET
TELECOMMUNICATION OUTLET
"X" INDICATES TYPE
SPEAKER
SPEAKER - WALL MOUNTED
MICROPHONE
VOLUME CONTROL
SIGNALING BELL
SINGLE FACE CLOCK - CEILING MOUNTED
SINGLE FACE CLOCK - WALL MOUNTED
DOUBLE FACE CLOCK - CEILING MOUNTED
DOUBLE FACE CLOCK - WALL MOUNTED
P
PT
FB
CP
VFD
CB
DP
PP
X
X
S
S
MIC
VC
B
USB RECEPTACLE
GENERATOR TRANSFER DEVICEGTD
REMOTE GENERATOR ANNUNCIATOR PANELRGP
AUTOMATIC TRANSFER SWITCHATS
SWITCHBOARD
BRANCH CIRCUIT PANEL BOARD - 208/120V
TRANSFORMER
DISTRIBUTION PANEL - 208/120V
SECURITY CAMERA
MOTION DETECTOR
SECURITY KEY SWITCH
DOOR CONTACT
KEY PAD
CARD READER
CIRCUIT BREAKER
DRAWOUT CIRCUIT BREAKER
MANUALLY/ OPERATED
SWITCH
AUTOMATIC OR MANUAL TRANSFER
SWITCH
FUSE
TRANSFORMER
CURRENT TRANSFORMER
POTENTIAL TRANSFORMER
LIGHTNING ARRESTOR
PANELBOARD
"X" INDICATES PANELBOARD NAME
GROUND
SECURITY KEY INTERLOCK
ENGINE GENERATOR
UTILITY METER
AMMETER
VOLTMETER
AMMETER SWITCH
VOLTMETER SWITCH
SURGE PROTECTIVE DEVICE
TIME DELAY RELAY
THERMAL OVERLOAD RELAY
NORMALLY OPEN CONTACTS
NORMALLY CLOSED CONTACTS
N.O. PUSH BUTTON SINGLE CIRCUIT
N.C. PUSH BUTTON SINGLE CIRCUIT
GROUND BUS
MD
K
DC
KP
CR
X
K
G
M
A
V
AS
VS
SPD
TDR
GB
DURESS PUSH BUTTON STATION
DELAYED EGRESS
DB
DE
REQUEST TO EXIT STATIONREX
MANUAL FIRE ALARM PULL STATION
SMOKE DETECTOR
DUCT SMOKE DETECTOR
THERMAL DETECTOR
FIRE ALARM BELL
FIRE ALARM AUDIBLE/VISUAL NOTIFICATION - WALL
MOUNT SPEAKER/STROBE
TAMPER SWITCH
FLOW SWITCH
FIRE ALARM CONTROL PANEL
FIRE ALARM ANNUNCIATOR PANEL
F
SD
DD
TD
F
F
TS
FS
FACP
FAA
NOTIFICATION APPLIANCE CIRCUIT EXTENDER PANELNAC
R E
F E
R T
O E
L E
C T
R
IC
A L
S T
A N
D A
R
H E
D U
L E
S
DIMMER OCCUPANCY SENSOR SWITCH
LOW VOLTAGE DIMMER SWITCH
POWER POLE - WIREMOLD TYPE
F FIRE ALARM AUDIBLE/VISUAL NOTIFICATION - CEILING
MOUNT SPEAKER/STROBE
CARBON MONOXIDE DETECTORCO
LIGHTING CONTROL DEVICE - REFER TO LIGHTING
CONTROL SCHEDULE
LC
K
D
OS
LV
GFI
USB
CLG
FLOOR BOX ASSEMBLY - LEGRAND
EVOLUTION SERIES OR EQUAL
TOUCH SCREEN SWITCHTS
OS
OCCUPANCY SENSOR DEVICE - WALLOS
PC PHOTOCELL DEVICE - REFER TO ZONES SHOWN ON
PLANS
EQ
EQUIPMENT CONNECTION - REFER TO ELECTRICAL
FEEDER AND PANEL SCHEDULE FOR BREAKER AND
CONDUCTOR SIZE/QUANTITY
J JUNCTION BOX
EMERGENCY POWER OFF BUTTON
V FIRE ALARM VISUAL NOTIFICATION - CEILING MOUNT
STROBE
FIRE ALARM VISUAL NOTIFICATION - WALL MOUNT
STROBE
V
BRANCH CIRCUIT PANEL BOARD - 480/277V
DISTRIBUTION PANEL - 480/277V
COMBINATION SMOKE DETECTOR - SMOKE/CARBON MONOXIDESD
S/C
S FIRE ALARM AUDIBLE NOTIFICATION - CEILING MOUNT
SPEAKER
FIRE ALARM AUDIBLE NOTIFICATION - WALL MOUNT
SPEAKER
S
EXIT FIXTURE-BACK
MOUNTED BOTTOM OF EXIT
SIGN TO BE 4" ABOVE TOP OF
DOOR FRAME
EXIT
EXIT
1' -6
EXIT
A/C SUPPLY
DIFFUSER
90" MAX (IBC)
4' -0
5"
8' -6
EXIT-CEILING MOUNTED
EXIT-FIXTURE END
MOUNTED
NFPA 72 AUDIBLE APPLIANCE 6" MIN
BELOW FINISHED CEILING
EMERGENCY
BATTERY
FIXTURE
ABOVE FINISHED FLOOR
AUDIBLE 80" MIN (IBC)
CEILING HEIGHTS LESS THEN 86" VISUAL
LENS MOUNTING HEIGHT WILL BE WITHIN 6"
OF THE CEILING
FINISHED CEILING
AUDIO/VISUAL &
VISUAL ONLY
DEVICES
SYNCHRONIZE MORE THAN
TWO APPLIANCES IN ANY
FIELD OF VIEW
MANUAL PULL STATION
AUDIBLE
ONLY
'-8
DOOR WIDTH LESS THEN 3'-0"
(MODIFY FOR DIFFERENT
DOOR WIDTHS)
FINISHED FLOOR
O R
A P
P R
O V
E D
F R
O M
A H
J
M
IN
B
O V
E F
IN
IS
H E
D F
L O
O R
CEILING MOUNTED SMOKE/HEAT
DETECTOR
3'-0" MIN 4"
NOTES:
1. INSTALL ELECTRICAL DEVICES AT MOUNTING HEIGHTS NOTED ABOVE UNLESS OTHERWISE NOTED ON PLANS. COORDINATE WITH ALL OTHER DISCIPLINES PRIOR TO INSTALL.
2. VISUAL MOUNTING APPLIANCE MOUNTING HEIGHT IN SLEEPING ROOMS:
A. MINIMUM DISTANCE IN SLEEPING ROOMS IS 24" FROM CEILING TO THE TOP OF LENS FOR 110cd STROBES WITHIN 16' OF PILLOW
B. 177cd STROBES, USED IN SLEEPING ROOMS, CAN BE WITHIN THE 24" MINIMUM DISTANCE FROM THE CEILING, THE HIGHER INTENSITY IS TO COMPENSATE FOR A POSSIBLE SMOKE LAYER
7' -6
(M
IN
(M
A X
1' -0
"4"
M A
X
DO NOT INSTALL HEAT DETECTOR IN
SHADED AREA
WALL MOUNTED
SMOKE/HEAT
DETECTOR
MAGNETIC
DOOR
HOLDER
FINISHED WALL
SWITCHBANK
AUTOMATIC DOOR OPERATOR PUSH
BUTTON
RECEPTACLE, DATA JACK OR
TELEPHONE JACK
3'-0"
5' MAX TO EXIT DOOR
4' -0
4"
7' -6
ELECTRICAL DEVICE TYPICAL MOUNTING HEIGHTS
6' -6
BRANCH CIRCUIT PANELBOARDS
DISCONNECT SWITCH
5' -0
KINGSCOTT ASSOCIATES INC. PORTAGE, MICHIGANCC
JOB NO.
SHEET TITLE
SHEET NO.
ISSUANCE DAT
N
P L
E A
S E
R E
C Y
C L
E
T H
E S
E D
R A
W
IN
G S
A N
D T
H E
W O
R K
R E
P R
E S
E N
T E
D T
H E
R E
IN
A
R E
T H
E P
R O
P E
R T
Y O
F A
P
Y R
IG
H
T
K
IN
G
S C
O T
T A
S S
O C
IA
T
D
M A
Y N
O T
B E
U S
E D
O R
R E
P R
O D
U C
H
O U
T P
E R
M
IS
S
IO
N
L A
S T
P R
IN
T
E D ljh
PORTAGE | CHELSEA | GRAND RAPIDS | DETROIT
/3
/2
:5 :1
A
M
A u to d e s k D o c s /G
P S
S in k in g F u n d
C e d a r
C re s t
E le m e n ta ry /C
E D
E R
C R
E S
T E
L E
M E
N T
A R
Y F
IR
E
A L A
R M
.r v t
25.118
ELECTRICAL SYMBOLS AND
GENERAL NOTES
E000
S
C E
D A
R S
T G
R E
E N
V
IL
L E
M
I
G R
E E
N V
IL
L E
P U
B L
IC
S
C H
O O
L S
C E
D A
R C
R E
S T
E L
E M
E N
T A
R Y
F
IR
E A
L A
R M
NOTE: SOME SYMBOLS AND ABBREVIATIONS SHOWN
MAY NOT APPLY TO THIS PROJECT.
GENERAL ELECTRICAL NOTES
1. CONTRACTOR TO PROCURE ALL REQUIRED BUILDING PERMITS AND INSPECTIONS TO COMPLETE PROJECT.
2. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE MICHIGAN ELECTRICAL CODE.
3. PROVIDE NEW ELECTRICAL SERVICES FROM CONSUMERS ENERGY AS INDICATED. COORDINATE SCOPE OF WORK AND PROVIDE ALL WORK TO PROVIDE A FULLY FUNCTIONAL ELECTRICAL SERVICE.
4. REMOVE ALL ELECTRICAL EQUIPMENT, WIRE, CONDUIT, ETC ASSOCIATED WITH DEMOLISHED EQUIPMENT.
5. REMOVE ALL ABANDONDED ELECTRICAL CONDUIT AND WIRE BACK TO SOURCE.
6. PROVIDE SHOP DRAWINGS FOR THE FOLLOWING:
A. CONDUIT.
B. CONDUCTORS.
C. WIRING DEVICES INCLUDING COVERPLATES.
D. DISCONNECT SWITCHES, ENCLOSED CIRCUIT BREAKERS AND FUSED SWITCHES.
E. PANELBOARDS. AND SWITCHBOARDS
F. TRANSFORMERS.
G. SURGE PROTECTION DEVICES
H. POWER METERS.
I. INTERIOR LIGHT FIXTURES.
J. EXTERIOR LIGHT FIXTURES INCLUDING SITE POLES.
K. LIGHTING CONTROL SYSTEM AND DEVICES.
L. FIRE ALARM SYSTEM.
7. PATCH, REPAIR, AND PAINT ANY OPENINGS THROUGH ROOF, CEILINGS, WALLS, OR FLOORS TO MATCH EXISTING CONDITION.
8. THE OWNER SHALL HAVE FIRST RIGHT OF REFUSAL OF ALL DEMOLISHED EQUIPMENT.
9. PROVIDE LAMACOID LABELS FOR:
A. PANELBOARDS AND SWITCHBOARDS.
B. TRANSFORMERS.
C. DISCONNECT SWITCHES.
D. VARIABLE FREQUENCY DRIVES.
E. LIGHTING CONTROL PANELS. LABEL SHALL INDICATE ROOMS CONTROLLED.
10. MINIMUM CONDUIT SIZE SHALL BE 1/2" TRADE SIZE.
11. USE THE CONDUIT TYPE SUITABLE FOR THE ENVIRONMENT IN WHICH IS IS LOCATED:
A. INDOORS: EMT WITH SET SCREW FITTINGS. MC CABLE IS ACCEPTABLE FOR BRANCH CIRCUITS WHERE CONCEALED.
B. OUTDOORS: RIGID GALVANIZED STEEL.
C. UNDERGROUND: RIGID NON METALLIC SCHEDULE 80 PVC.
D. CONDUIT EXITING FROM UNDERGROUND SHALL TRANSITION TO EMT/RGS PRIOR TO BEING EXPOSED.
12. PROVIDE CONDUIT SLEEVES FOR LOW VOLTAGE DATA CABLING.
13. ALL CABLING SHALL BE IN CONDUIT UNLESS ABOVE AN ACCESSIBLE CEILING WHERE "J" HOOKS ARE ACCEPTABLE.
14. USE CONDUIT SWEEPS FOR ALL DATA CABLING CONDUITS.
15. DATA BOXES SHALL BE DOUBLE GANG, 3 1/2" DEEP WITH SINGLE GANG MUD RING WITH 1" CONDUIT TO ABOVE ACCESSIBLE CEILING.
16. ALL BOXES SHALL BE RECESSED IN WALLS AND CONDUIT CONCEALED WHERE POSSIBLE.
17. EMERGENCY CIRCUITS SHALL NOT BE IN CONDUIT WITH OTHER NON-EMERGNECY CIRCUITS.
18. MINIMUM CONDUCTOR SIZE FOR POWER SHALL BE #12 AWG. ANY BRANCH CIRCUITS OVER 100' IN LENGTH SHALL BE #10 AWG MINIMUM FOR VOLTAGE DROP.
19. PROVIDE THHN-2 COPPER INDOORS AND THWN-2 COPPER OUTDOORS, UNLESS NOTED OTHERWISE OR DICTATED OTHERWISE BY THE NEC.
20. PROVIDE GROUNDING ELECTRODE SYSTEM AND EQUIPMENT GROUNDING PER THE NATIONAL ELECTRIC CODE.
21. PANELBOARDS SHALL BE FULLY RATED, SERIES RATED PANELS ARE NOT ACCEPTABLE. HAVE HINGED SWING DOOR-IN-DOOR. LOAD CENTERS ARE NOT ACCEPTABLE. SQUARE D NQOD OR EQUAL FOR
208/120V BRANCH PANELBOARDS. SQUARE D NF OR EQUAL FOR 480/277V PANELBOARDS. PROVIDE TYPED PANELBOARD CIRCUIT LABEL CARDS. UPDATE ALL EXISTING LABEL CARDS AS REQUIRED.
22. SURGE PROTECTION DEVICES SHALL BE MOUNTED AS CLOSE TO MAIN BUS AS POSSIBLE TO LIMIT FEEDER LENGTH.
23. ALL FLOOR MOUNTED EQUIPMENT SHALL BE ON 4" HOUSEKEEPING PAD.
24. RECEPTACLES SHALL BE TAMPER-RESISTANT EXTRA HEAVY DUTY GRADE, 20AMP MINIMUM. WHITE IN COLOR UNLESS NOTED OTHERWISE.
25. ALL DEVICE COVERS SHALL MATCH DEVICE COLOR UNLESS STAINLESS STEEL COVERS ARE SPECIFIED.
26. WEATHERPROOF RECEPTACLE COVERS SHALL BE METAL, WHILE-IN-USE TYPE.
27. SWITCHES SHALL BE HEAVY DUTY GRADE, 20 AMP, QUIET TYPE, WHITE UNLESS NOTED OTHERWISE.
28. LIGHTING CONTROL DEVICES SHALL BE MANUFACTURED BY N-LIGHT, UNLESS NOTED OTHERWISE.
29. ALL LIGHTING CONTROLS SHALL MEET ASHRAE 90.1 - 2013 WITH MICHIGAN AMENDMENTS.
30. IT IS UNDERSTOOD AND AGREED BY THE INSTALLER THAT WORK HEREIN DESCRIBED SHALL BE COMPLETE IN EVERY DETAIL, EVEN THOUGH EVERY ITEM INVOLVED IS NOT PARTICULARLY MENTIONED.
INSTALLER SHALL BE HELD TO PROVIDE ALL LABOR AND MATERIALS NECESSARY FOR THE WORK INTENDED AND DESCRIBED FOR A COMPLETE AND OPERATIONAL SYSTEM. SUCH MATERIALS SHALL
INCLUDE, BUT ARE NOT LIMITED TO, CONDUIT, FITTINGS, COVERPLATES, WIRING, BREAKERS, CONTROL DEVICES, LIGHTING ACCESSORIES, ETC. THIS ALSO INCLUDES EQUIPMENT REQUIRED BY STATE AND
LOCAL CODES.
CONSTRUCTION DOCUMENTS 7/30/2026
SD
H
D H
SD
V V
V
F
F
F
F F
F
VV
V
V
V
V
V
V V
V V
V V
F
F
C
AB
HH
NH1A
UNIT A
UNIT C
UNIT A
UNIT C
1 1
1 1
1 1
1 1
NM1
T-NM1
KINGSCOTT ASSOCIATES INC. PORTAGE, MICHIGANCC
JOB NO.
SHEET TITLE
SHEET NO.
ISSUANCE DAT
N
P L
E A
S E
R E
C Y
C L
E
T H
E S
E D
R A
W
IN
G S
A N
D T
H E
W O
R K
R E
P R
E S
E N
T E
D T
H E
R E
IN
A
R E
T H
E P
R O
P E
R T
Y O
F A
P
Y R
IG
H
T
K
IN
G
S C
O T
T A
S S
O C
IA
T
D
M A
Y N
O T
B E
U S
E D
O R
R E
P R
O D
U C
H
O U
T P
E R
M
IS
S
IO
N
L A
S T
P R
IN
T
E D ljh
PORTAGE | CHELSEA | GRAND RAPIDS | DETROIT
/3
/2
:5 :1
A
M
A u to d e s k D o c s /G
P S
S in k in g F u n d
C e d a r
C re s t
E le m e n ta ry /C
E D
E R
C R
E S
T E
L E
M E
N T
A R
Y F
IR
E
A L A
R M
.r v t
25.118
FIRST FLOOR ELECTRICAL
DEMOLITION PLAN - UNIT A
ED110A
S
C E
D A
R S
T G
R E
E N
V
IL
L E
M
I
G R
E E
N V
IL
L E
P U
B L
IC
S
C H
O O
L S
C E
D A
R C
R E
S T
E L
E M
E N
T A
R Y
F
IR
E A
L A
R M
ELECTRICAL DEMOLITION KEYED NOTES
1 REMOVE EXISTING FIRE ALARM DEVICE AND ASSOCIATED CABLING
BACK TO SOURCE. FULL BUILDING FIRE ALARM SYSTEM TO BE
REPLACED IN NEW CONSTRUCTION. PROVIDE STAINLESS STEEL
COVER PLATE OVER EXISTING JUNCTION BOX WHERE DEVICE IS
REMOVED AND NOT REPLACED IN SAME LOCATION.
2 REMOVE EXISTING FIRE ALARM CONTROL PANEL AND ALL
ASSOCIATED CABLING AND ACCESSORIES. FULL BUILDING FIRE
ALARM SYSTEM TO BE REPLACED IN NEW CONSTRUCTION.
1/8" = 1'-0"ED110A
1 FIRST FLOOR ELECTRICAL DEMOLITION PLAN - UNIT A
F
VVVVV
VVV
F
FF
VVVF
F
F
F
F
F
F
V
V
V V
DD
H
BB
CC
U N
IT
B
U N
IT
C
U N
IT
B
U N
IT
C
1 1 1 1
1 1 1
1 1 1
1 1
AHU-4
KINGSCOTT ASSOCIATES INC. PORTAGE, MICHIGANCC
JOB NO.
SHEET TITLE
SHEET NO.
ISSUANCE DAT
N
P L
E A
S E
R E
C Y
C L
E
T H
E S
E D
R A
W
IN
G S
A N
D T
H E
W O
R K
R E
P R
E S
E N
T E
D T
H E
R E
IN
A
R E
T H
E P
R O
P E
R T
Y O
F A
P
Y R
IG
H
T
K
IN
G
S C
O T
T A
S S
O C
IA
T
D
M A
Y N
O T
B E
U S
E D
O R
R E
P R
O D
U C
H
O U
T P
E R
M
IS
S
IO
N
L A
S T
P R
IN
T
E D ljh
PORTAGE | CHELSEA | GRAND RAPIDS | DETROIT
/3
/2
:5 :1
A
M
A u to d e s k D o c s /G
P S
S in k in g F u n d
C e d a r
C re s t
E le m e n ta ry /C
E D
E R
C R
E S
T E
L E
M E
N T
A R
Y F
IR
E
A L A
R M
.r v t
25.118
FIRST FLOOR ELECTRICAL
DEMOLITION PLAN - UNIT B
ED110B
S
C E
D A
R S
T G
R E
E N
V
IL
L E
M
I
G R
E E
N V
IL
L E
P U
B L
IC
S
C H
O O
L S
C E
D A
R C
R E
S T
E L
E M
E N
T A
R Y
F
IR
E A
L A
R M
ELECTRICAL DEMOLITION KEYED NOTES
1 REMOVE EXISTING FIRE ALARM DEVICE AND ASSOCIATED CABLING
BACK TO SOURCE. FULL BUILDING FIRE ALARM SYSTEM TO BE
REPLACED IN NEW CONSTRUCTION. PROVIDE STAINLESS STEEL
COVER PLATE OVER EXISTING JUNCTION BOX WHERE DEVICE IS
REMOVED AND NOT REPLACED IN SAME LOCATION.
2 REMOVE EXISTING FIRE ALARM CONTROL PANEL AND ALL
ASSOCIATED CABLING AND ACCESSORIES. FULL BUILDING FIRE
ALARM SYSTEM TO BE REPLACED IN NEW CONSTRUCTION.
1/8" = 1'-0"ED110B
1 FIRST FLOOR ELECTRICAL DEMOLITION PLAN - UNIT B
V V
V
F
F F
F
F
F
F
D H
D H
SD
SD
SD
DH
DH
SDSD
F
F
F
F
F
V
F
F
F F
F
F
F
DD
DD
DD
DD
V
VV
V
F
SD
D H
D H
V
D H
DH
SD SD
F
F
F
V
V
F
F F
F
F
DD
DD
F
F
SD
SD
F
F
F
F
F
F
FF
F A
C P
SD
V V
V
F
J
DP-AA
HH
GG
D
G
DDEM
JJF
AA
UNIT A
UNIT C
UNIT A
UNIT C
U N
IT
B
U N
IT
C
U N
IT
B
U N
IT
C
1 1
1 1
AHU-1 AHU-2
IN MEZZANINE
ABOVE
IN MEZZANINE
ABOVE
1 1
AHU-3
IN MEZZANINE
ABOVE
1 1
1 1
KINGSCOTT ASSOCIATES INC. PORTAGE, MICHIGANCC
JOB NO.
SHEET TITLE
SHEET NO.
ISSUANCE DAT
N
P L
E A
S E
R E
C Y
C L
E
T H
E S
E D
R A
W
IN
G S
A N
D T
H E
W O
R K
R E
P R
E S
E N
T E
D T
H E
R E
IN
A
R E
T H
E P
R O
P E
R T
Y O
F A
P
Y R
IG
H
T
K
IN
G
S C
O T
T A
S S
O C
IA
T
D
M A
Y N
O T
B E
U S
E D
O R
R E
P R
O D
U C
H
O U
T P
E R
M
IS
S
IO
N
L A
S T
P R
IN
T
E D ljh
PORTAGE | CHELSEA | GRAND RAPIDS | DETROIT
/3
/2
:5 :1
A
M
A u to d e s k D o c s /G
P S
S in k in g F u n d
C e d a r
C re s t
E le m e n ta ry /C
E D
E R
C R
E S
T E
L E
M E
N T
A R
Y F
IR
E
A L A
R M
.r v t
25.118
FIRST FLOOR ELECTRICAL
DEMOLITION PLAN - UNIT C
ED110C
S
C E
D A
R S
T G
R E
E N
V
IL
L E
M
I
G R
E E
N V
IL
L E
P U
B L
IC
S
C H
O O
L S
C E
D A
R C
R E
S T
E L
E M
E N
T A
R Y
F
IR
E A
L A
R M
ELECTRICAL DEMOLITION KEYED NOTES
1 REMOVE EXISTING FIRE ALARM DEVICE AND ASSOCIATED CABLING
BACK TO SOURCE. FULL BUILDING FIRE ALARM SYSTEM TO BE
REPLACED IN NEW CONSTRUCTION. PROVIDE STAINLESS STEEL
COVER PLATE OVER EXISTING JUNCTION BOX WHERE DEVICE IS
REMOVED AND NOT REPLACED IN SAME LOCATION.
2 REMOVE EXISTING FIRE ALARM CONTROL PANEL AND ALL
ASSOCIATED CABLING AND ACCESSORIES. FULL BUILDING FIRE
ALARM SYSTEM TO BE REPLACED IN NEW CONSTRUCTION.
1/8" = 1'-0"ED110C
1 FIRST FLOOR ELECTRICAL DEMOLITION PLAN - UNIT C
AB
HH
GG
DP-AADDEM
G
D
AA
H
BB
CC
NM1
T-NM1
JJF
NH1A
UNIT A
UNIT C
UNIT A
UNIT C
U N
IT
B
U N
IT
C
U N
IT
B
U N
IT
C
NH1C
FIRE ALARM CONTROL
PANEL LOCATION
FACP
FIRE ALARM
CONTROL PANEL
F
WP
BUILDING EXTERIOR AT
F.D. CONNECTION
FFVV
S
HORN STROBESSTROBES
SPEAKERS
TO ADDITIONAL
DEVICES
DD
RT
RESET/TEST
STATION
TO ADDITIONAL
DEVICES
SD SD HD
DUCT ELEV SMOKE HEAT
DETECTORS
AT ELEVATOR LANDING(S). COORDINATE
WITH ELEVATOR MANUFACTURER
SD DH F
TO ADDITIONAL
DEVICES SMOKE
DAMPERS
DOOR
HOLDS
PULL
STATIONS
MISCELLANEOUS
SPECIAL CONNECTIONS
FAA
REMOTE
ANNUNCIATOR
(2) DEDICATED PHONE LINES TO
BUILDING PHONE SYSTEM
DEDICATED 120V CIRCUIT; PROVIDE
CIRCUIT BREAKER LOCKOUT
BUILDING
EQUIPMENT
GROUND
IAM
OSY
WF
WATER FLOW
SWITCH
TAMPER
SWITCH
INDIVIDUAL
ADDRESSABLE MODULE
TO ADDITIONAL
DEVICES
ZAM
FS
FIRE
SHUTTER
ZONE ADAPTOR
MODULE
TO ADDITIONAL
DEVICES
BUIDLING LIGHTING
CONTROL SYSTEM
LCS
SD SD
R
5'-0" MAX 15'-0" MAX
FIRE ALARM RELAY FOR SMOKE DAMPER
CONTROL
(REFER TO MECHANICAL PLANS FOR
DAMPER LOCATIONS)
CENTERLINE OF CORRIDOR
DOORS WITH JAMB 24" OR LESS TO CEILING
SHALL HAVE SMOKE DETECTOR WITHIN 5'-0" ON
ONE SIDE OF DOORS AND WITHIN 15'-0" ON OTHER
SIDE
NOTE:
SMOKE DETECTORS TO BE INSTALLED ON ALL FIRE RATED
DOORS (REFER TO ARCHITECTURAL PLANS) AND ALL OTHER
REQUIRED DOORS IN ACCORDANCE WITH NFPA 72
KINGSCOTT ASSOCIATES INC. PORTAGE, MICHIGANCC
JOB NO.
SHEET TITLE
SHEET NO.
ISSUANCE DAT
N
P L
E A
S E
R E
C Y
C L
E
T H
E S
E D
R A
W
IN
G S
A N
D T
H E
W O
R K
R E
P R
E S
E N
T E
D T
H E
R E
IN
A
R E
T H
E P
R O
P E
R T
Y O
F A
P
Y R
IG
H
T
K
IN
G
S C
O T
T A
S S
O C
IA
T
D
M A
Y N
O T
B E
U S
E D
O R
R E
P R
O D
U C
H
O U
T P
E R
M
IS
S
IO
N
L A
S T
P R
IN
T
E D ljh
PORTAGE | CHELSEA | GRAND RAPIDS | DETROIT
/3
/2
:5 :2
A
M
A u to d e s k D o c s /G
P S
S in k in g F u n d
C e d a r
C re s t
E le m e n ta ry /C
E D
E R
C R
E S
T E
L E
M E
N T
A R
Y F
IR
E
A L A
R M
.r v t
25.118
OVERALL POWER PLAN
E110
S
C E
D A
R S
T G
R E
E N
V
IL
L E
M
I
G R
E E
N V
IL
L E
P U
B L
IC
S
C H
O O
L S
C E
D A
R C
R E
S T
E L
E M
E N
T A
R Y
F
IR
E A
L A
R M
1/16" = 1'-0"E110
1 OVERALL POWER PLAN
NOT TO SCALEE110
2 FIRE ALARM SYSTEM RISER DIAGRAM
NOT TO SCALEE110
3 CROSS CORRIDOR SMOKE DETECTOR/DAMPER DOOR INTERFACE DETAIL
SD
H
D H
SD
F
F SD
F
SD SD
F SD
F SD F SD
F SD F SD
F SD F SD
F SD
SD SD
SDSD
F F
V V
F F
F
F
F SD
F SD
F
F SD
F SD F SD
F SD
F
SDS
SDS
SDF
SDS
F
SD SD
AB
C
HH
NM1
T-NM1
NH1A
UNIT A
UNIT C
UNIT A
UNIT C
S/C
S/C
S/C
S/C S/C
S/C
S/C S/C
S/C S/C
S/C S/C
S/C
S/C S/C
S/CS/C
S/C
S/C
S/C
S/C S/C
S/C
S/C
S/C
S/C
S/C
1 1
3'-0" 3'-0"
1 2
HIGH-POINT OF SLOPED
ROOF DECK ABOVE
AREA OF EXPOSED
STRUCTURE
1 2
1 2
S/C S/C
1 2 1 2
10 10
KINGSCOTT ASSOCIATES INC. PORTAGE, MICHIGANCC
JOB NO.
SHEET TITLE
SHEET NO.
ISSUANCE DAT
N
P L
E A
S E
R E
C Y
C L
E
T H
E S
E D
R A
W
IN
G S
A N
D T
H E
W O
R K
R E
P R
E S
E N
T E
D T
H E
R E
IN
A
R E
T H
E P
R O
P E
R T
Y O
F A
P
Y R
IG
H
T
K
IN
G
S C
O T
T A
S S
O C
IA
T
D
M A
Y N
O T
B E
U S
E D
O R
R E
P R
O D
U C
H
O U
T P
E R
M
IS
S
IO
N
L A
S T
P R
IN
T
E D ljh
PORTAGE | CHELSEA | GRAND RAPIDS | DETROIT
/3
/2
:5 :2
A
M
A u to d e s k D o c s /G
P S
S in k in g F u n d
C e d a r
C re s t
E le m e n ta ry /C
E D
E R
C R
E S
T E
L E
M E
N T
A R
Y F
IR
E
A L A
R M
.r v t
25.118
FIRST FLOOR POWER PLAN -
UNIT A
E110A
S
C E
D A
R S
T G
R E
E N
V
IL
L E
M
I
G R
E E
N V
IL
L E
P U
B L
IC
S
C H
O O
L S
C E
D A
R C
R E
S T
E L
E M
E N
T A
R Y
F
IR
E A
L A
R M
ELECTRICAL POWER KEYED NOTES
1 PENDANT MOUNT NEW FIRE ALARM DEVICE(S) FROM STRUCTURE
ABOVE. PAINT CONDUIT AND BOX(ES) TO MATCH COLOR OF
STRUCTURE ABOVE.
2 PENDANT MOUNT NEW FIRE ALARM DEVICE(S) WITHIN 12" OF CEILING
DECK ABOVE.
3 PROVIDE SMOKE DETECTION WITHIN 36" HORIZONTALLY FROM PEAK
OF SLOPED ROOF DECK ABOVE.
4 PROVIDE NEW MAGNETIC DOOR HOLD OPEN IN PLACE OF
DEMOLISHED FIRE ALARM DEVICE. TIE DOOR HOLD OPEN TO FIRE
ALARM SYSTEM TO RELEASE DOOR UPON ACTIVATION OF SMOKE
DETECTION.
5 PROVIDE NEW DUCT DETECTOR(S) IN PLACE OF EXISTING. PROVIDE
ALL REQUIRED WIRING AND PROGRAMMING TO PROPERLY SHUT
DOWN MECHANICAL UNIT UPON DETECTION OF SMOKE.
6 INSTALL NEW FIRE ALARM SYSTEM CONTROL PANEL IN PLACE OF
DEMOLISHED EQUIPMENT. NEW FIRE ALARM SYSTEM SHALL BE
VOICE CAPABLE, ADDRESSABLE AND PROVIDE MANUAL AND
AUTOMATIC ALARM INITIATION. PROVIDE DEDICATED 120V CIRCUIT
FROM PANEL "GG" WITH LOCKOUT TYPE CIRCUIT BREAKER.
7 PROVIDE PROTECTIVE WIREGUARD OVER FIRE ALARM DEVICE.
COORDINATE FINAL GUARD SELECTION WITH OWNER.
8 MOUNT FIRE ALARM DEVICE AT TOP OF STAIRS IN MEZZANINE ABOVE.
9 CONNECT EXISTING KITCHEN HOOD FIRE SUPPRESSION SYSTEM TO
NEW BUILDING FIRE ALARM SYSTEM. PROVIDE ALL REQUIRED WIRING
AND PROGRAMMING TO MONITOR KITCHEN HOOD FIRE SUPPRESSION.
10 ALTERNATE #2: PROVIDE SEPARATE COST TO INCLUDE SMOKE
DETECTION IN SPACE NOT CURRENTLY LICENSED FOR EARLY
CHILDHOOD.
8' 16'4'0 1/8" = 1'-0"E110A
1 FIRST FLOOR POWER PLAN - UNIT A
VVVF
F
F
DD
DD
SDF
SDFSDFSDFSDFSDF
SDF
SD
F
SD
F
SD
F
SD
F
SD
F
SDFSDFSDF
SDSD
SDF
V V
F
F
F
V
F
H
BB
CC
U N
IT
B
U N
IT
C
U N
IT
B
U N
IT
C
AHU-4
S/C
S/CS/CS/CS/CS/C
S/C
S/CS/CS/CS/CS/C
S/CS/CS/C
S/CS/C
S/C
10101010
KINGSCOTT ASSOCIATES INC. PORTAGE, MICHIGANCC
JOB NO.
SHEET TITLE
SHEET NO.
ISSUANCE DAT
N
P L
E A
S E
R E
C Y
C L
E
T H
E S
E D
R A
W
IN
G S
A N
D T
H E
W O
R K
R E
P R
E S
E N
T E
D T
H E
R E
IN
A
R E
T H
E P
R O
P E
R T
Y O
F A
P
Y R
IG
H
T
K
IN
G
S C
O T
T A
S S
O C
IA
T
D
M A
Y N
O T
B E
U S
E D
O R
R E
P R
O D
U C
H
O U
T P
E R
M
IS
S
IO
N
L A
S T
P R
IN
T
E D ljh
PORTAGE | CHELSEA | GRAND RAPIDS | DETROIT
/3
/2
:5 :2
A
M
A u to d e s k D o c s /G
P S
S in k in g F u n d
C e d a r
C re s t
E le m e n ta ry /C
E D
E R
C R
E S
T E
L E
M E
N T
A R
Y F
IR
E
A L A
R M
.r v t
25.118
FIRST FLOOR POWER PLAN -
UNIT B
E110B
S
C E
D A
R S
T G
R E
E N
V
IL
L E
M
I
G R
E E
N V
IL
L E
P U
B L
IC
S
C H
O O
L S
C E
D A
R C
R E
S T
E L
E M
E N
T A
R Y
F
IR
E A
L A
R M
ELECTRICAL POWER KEYED NOTES
1 PENDANT MOUNT NEW FIRE ALARM DEVICE(S) FROM STRUCTURE
ABOVE. PAINT CONDUIT AND BOX(ES) TO MATCH COLOR OF
STRUCTURE ABOVE.
2 PENDANT MOUNT NEW FIRE ALARM DEVICE(S) WITHIN 12" OF CEILING
DECK ABOVE.
3 PROVIDE SMOKE DETECTION WITHIN 36" HORIZONTALLY FROM PEAK
OF SLOPED ROOF DECK ABOVE.
4 PROVIDE NEW MAGNETIC DOOR HOLD OPEN IN PLACE OF
DEMOLISHED FIRE ALARM DEVICE. TIE DOOR HOLD OPEN TO FIRE
ALARM SYSTEM TO RELEASE DOOR UPON ACTIVATION OF SMOKE
DETECTION.
5 PROVIDE NEW DUCT DETECTOR(S) IN PLACE OF EXISTING. PROVIDE
ALL REQUIRED WIRING AND PROGRAMMING TO PROPERLY SHUT
DOWN MECHANICAL UNIT UPON DETECTION OF SMOKE.
6 INSTALL NEW FIRE ALARM SYSTEM CONTROL PANEL IN PLACE OF
DEMOLISHED EQUIPMENT. NEW FIRE ALARM SYSTEM SHALL BE
VOICE CAPABLE, ADDRESSABLE AND PROVIDE MANUAL AND
AUTOMATIC ALARM INITIATION. PROVIDE DEDICATED 120V CIRCUIT
FROM PANEL "GG" WITH LOCKOUT TYPE CIRCUIT BREAKER.
7 PROVIDE PROTECTIVE WIREGUARD OVER FIRE ALARM DEVICE.
COORDINATE FINAL GUARD SELECTION WITH OWNER.
8 MOUNT FIRE ALARM DEVICE AT TOP OF STAIRS IN MEZZANINE ABOVE.
9 CONNECT EXISTING KITCHEN HOOD FIRE SUPPRESSION SYSTEM TO
NEW BUILDING FIRE ALARM SYSTEM. PROVIDE ALL REQUIRED WIRING
AND PROGRAMMING TO MONITOR KITCHEN HOOD FIRE SUPPRESSION.
10 ALTERNATE #2: PROVIDE SEPARATE COST TO INCLUDE SMOKE
DETECTION IN SPACE NOT CURRENTLY LICENSED FOR EARLY
CHILDHOOD.
8' 16'4'0 1/8" = 1'-0"E110B
1 FIRST FLOOR POWER PLAN - UNIT B
F
D H
D H
DH
DH
F
F
F
F
F
F
DD
DD
DD
DD
V
D H
D H
D H
DH
F
F
F F
F
F
DD
DD
F
F
F
F
F
F A
C P
SD
F SD F SD
V
F SD
F SD
F
F SDF SD
SDS
SDF
SDF
SDF
F SD
F
F
F SD
F SD
V SD
V SD
V
SDF
SDF
SD
F
SD
F
SD
F
SD
F
SD
F
SD
F
SD
SDF
SDS
SDF
SDF
F
V
V
F
SDF
SDF
V
V
F
F
SDF
SDFSDF
SD
F
SD
F
SDF
F
F
F
F
SD
SD
SD
SD
SD
SD
SD
J
HH
GG
DP-AADDEM
G
D
AA
JJF
UNIT A
UNIT C
UNIT A
UNIT C
U N
IT
B
U N
IT
C
U N
IT
B
U N
IT
C
S/C S/C
S/C
S/C
S/CS/C
S/C
S/C
S/C
S/C
S/C
S/C
S/C
S/C
S/C
AHU-3
AHU-2AHU-1
WG
WG
S/C
S/C
S/C S/CS/CS/CS/C
S/C
S/C
S/C
S/C
S/C
S/C
S/C
S/C
IN MEZZANINE
ABOVE
IN MEZZANINE
ABOVE
IN MEZZANINE
ABOVE
S/C
S/CS/C
S/CS/C
S/C
NH1C
4 4
5 5
WG
WG
S/C, WG
S/C, WG
S/C, WG
S/C, WG
S/C, WG
S/C, WG
1 2 71 271 2
71 2 71 271 2
S/C
KINGSCOTT ASSOCIATES INC. PORTAGE, MICHIGANCC
JOB NO.
SHEET TITLE
SHEET NO.
ISSUANCE DAT
N
P L
E A
S E
R E
C Y
C L
E
T H
E S
E D
R A
W
IN
G S
A N
D T
H E
W O
R K
R E
P R
E S
E N
T E
D T
H E
R E
IN
A
R E
T H
E P
R O
P E
R T
Y O
F A
P
Y R
IG
H
T
K
IN
G
S C
O T
T A
S S
O C
IA
T
D
M A
Y N
O T
B E
U S
E D
O R
R E
P R
O D
U C
H
O U
T P
E R
M
IS
S
IO
N
L A
S T
P R
IN
T
E D ljh
PORTAGE | CHELSEA | GRAND RAPIDS | DETROIT
/3
/2
:5 :2
A
M
A u to d e s k D o c s /G
P S
S in k in g F u n d
C e d a r
C re s t
E le m e n ta ry /C
E D
E R
C R
E S
T E
L E
M E
N T
A R
Y F
IR
E
A L A
R M
.r v t
25.118
FIRST FLOOR POWER PLAN -
UNIT C
E110C
S
C E
D A
R S
T G
R E
E N
V
IL
L E
M
I
G R
E E
N V
IL
L E
P U
B L
IC
S
C H
O O
L S
C E
D A
R C
R E
S T
E L
E M
E N
T A
R Y
F
IR
E A
L A
R M
ELECTRICAL POWER KEYED NOTES
1 PENDANT MOUNT NEW FIRE ALARM DEVICE(S) FROM STRUCTURE
ABOVE. PAINT CONDUIT AND BOX(ES) TO MATCH COLOR OF
STRUCTURE ABOVE.
2 PENDANT MOUNT NEW FIRE ALARM DEVICE(S) WITHIN 12" OF CEILING
DECK ABOVE.
3 PROVIDE SMOKE DETECTION WITHIN 36" HORIZONTALLY FROM PEAK
OF SLOPED ROOF DECK ABOVE.
4 PROVIDE NEW MAGNETIC DOOR HOLD OPEN IN PLACE OF
DEMOLISHED FIRE ALARM DEVICE. TIE DOOR HOLD OPEN TO FIRE
ALARM SYSTEM TO RELEASE DOOR UPON ACTIVATION OF SMOKE
DETECTION.
5 PROVIDE NEW DUCT DETECTOR(S) IN PLACE OF EXISTING. PROVIDE
ALL REQUIRED WIRING AND PROGRAMMING TO PROPERLY SHUT
DOWN MECHANICAL UNIT UPON DETECTION OF SMOKE.
6 INSTALL NEW FIRE ALARM SYSTEM CONTROL PANEL IN PLACE OF
DEMOLISHED EQUIPMENT. NEW FIRE ALARM SYSTEM SHALL BE
VOICE CAPABLE, ADDRESSABLE AND PROVIDE MANUAL AND
AUTOMATIC ALARM INITIATION. PROVIDE DEDICATED 120V CIRCUIT
FROM PANEL "GG" WITH LOCKOUT TYPE CIRCUIT BREAKER.
7 PROVIDE PROTECTIVE WIREGUARD OVER FIRE ALARM DEVICE.
COORDINATE FINAL GUARD SELECTION WITH OWNER.
8 MOUNT FIRE ALARM DEVICE AT TOP OF STAIRS IN MEZZANINE ABOVE.
9 CONNECT EXISTING KITCHEN HOOD FIRE SUPPRESSION SYSTEM TO
NEW BUILDING FIRE ALARM SYSTEM. PROVIDE ALL REQUIRED WIRING
AND PROGRAMMING TO MONITOR KITCHEN HOOD FIRE SUPPRESSION.
10 ALTERNATE #2: PROVIDE SEPARATE COST TO INCLUDE SMOKE
DETECTION IN SPACE NOT CURRENTLY LICENSED FOR EARLY
CHILDHOOD.
8' 16'4'0 1/8" = 1'-0"E110C
1 FIRST FLOOR POWER PLAN - UNIT C
| Sheets |
| G0.1 - TITLE SHEET |