2025.06.26 -Permit Issue Set Addendum 2 - ODF Astoria District.pdf

PDF 2 MB Posted

Attached to
Roofing and siding Rehabilitation
Solicitation number
S-62900-00011088
Issued by
Clatsop County, Oregon

About this file

This document is a permit issue set for the Oregon Department of Forestry's Astoria District Building Roof and Siding Rehabilitation Project, located at 92219 Highway 202 in Astoria, Oregon. The project involves comprehensive rehabilitation of seven existing facility buildings, with primary focus on the main office building. The scope includes complete removal and replacement of exterior components such as siding, windows, doors, and roofing across multiple structures. Specific work includes removing and disposing of existing hardboard and fiber cement wall cladding, vinyl window assemblies, asphalt shingle roofing, and installing new weather-resistant barriers, flashings, fiber cement cladding, windows, and roofing materials.

The project is structured as a single-phase rehabilitation effort to be performed while buildings remain occupied, with work potentially not occurring in numerical order relative to site layout. The estimated work includes targeted repairs and full replacements across different buildings, with varying extents of intervention. Estimated quantities include removal and replacement of approximately 200 square feet of roofing and 128 square feet of plywood roof deck sheathing for several buildings. The project is designed under 2022 Oregon Structural Specialty Code and other relevant state building and safety codes, with a permit issue date of May 14, 2025, and a bidding issue addendum date of June 26, 2026. The contract is being managed by Forensic Building Consultants, with the Oregon Department of Forestry as the primary client.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VICINITY MAP

N

PROJECT INFORMATION:

ADDRESS:

Oregon Department of Forestry Astoria District 92219 Highway 202, Astoria, OR 97103 PO Box 950 Astoria, OR 97103

LEGAL DESCRIPTION:

Township 8N, Range 9W, Section 27, Tax Lot 2000, Clatsop County,

32.70 Acres

PERMIT No.:

TBD

PROJECT SUMMARY:

This Design Contract Document package is for Permit Issue purposes and are for project construction. Refer to sheets A0.00, A1.00 Architectural Site Plan, and to the Project Manual Summary of Work section for full project scope, basis of design, and description.

PROJECT DESIGN / ASSEMBLY GROUPS:

A0.00 COVER SHEET, GENERAL NOTES, ABBREVIATIONS &

SYMBOLS, CODE REVIEW, AND PROJECT DESCRIPTION

A0.10 SHEET SEQUENCE AND DETAIL INDEX

A1.00 SITE PLAN AND ROOF PLAN SHEETS

A2.00 REFERENCE BUILDING ELEVATIONS PHOTOS

A3.00 WALL DETAILS

A4.00 WALL OPENING DETAILS

A5.00 ROOF DETAILS

Building H: Chemical Storage Warehouse - North Elevation View Aerial View - Looking North

05.14.2025 - PERMIT ISSUE SET

Oregon Department of Forestry - Astoria District Building

Roof and Siding Rehabilitation Project Drawings (PO-62900-00046358)

PROJECT

LOCATION

EXISTING USE AND OCCUPANCY:

1. Zoning: LR (Land Reserve)

2. Zoning Overlay: n/a

3. Occupancy Groups: B, S, U

4. Construction Type: Type VB

5. County Seat: Clatsop (Unincorporated)

6. Tax Account: 60164 & 27465 (Included for Coordination)

7. Tax Map: 80927 0002000 (Included for Coordination)

SITE AREAS AND BUILDING HEIGHTS:

1. Site Area: 32.68 AC. (Unchanged)

2. Number of Buildings: 7 (Unchanged)

3. Total Site Building Area: 16,925 SF (Existing) (Unchanged)

4. Number of Stories: Varies (Existing) (Unchanged)

5. Existing Building Heights: (Existing) (Unchanged)

APPLICABLE PROJECT CODES:

1. BUILDING CODES IN EFFECT AT TIME OF REHABILITATION PROJECT:

· STATE OF OREGON 2022 OREGON STRUCTURAL SPECIALTY CODE

(O.S.S.C.) AMENDMENTS (BASED ON 2021 IBC)

· 2021 OREGON ENERGY EFFICIENCY SPECIALTY CODE (OEESC)

· 2022 OREGON MECHANICAL SPECIALTY CODE (BASED ON THE 2021 IMC

& INTERNATIONAL FUEL GAS CODE (IFGC)

· 2021 PORTLAND FIRE CODE AND THE 2019 OREGON FIRE CODE

· 2021 OREGON ELECTRICAL SPECIALTY CODE (BASED ON THE 2020 NFPA

70 - NATIONAL ELECTRICAL CODE)

· 2021 OREGON PLUMBING SPECIALTY CODE (BASED ON THE 2021

UNIFORM PLUMBING CODE)

REHABILITATION:

1. IT IS THE OWNER'S INTENT TO PERFORM THE REHABILITATION WITHIN THE

LIMITS WORK AREA WHILE THE BUILDINGS ARE OCCUPIED.

2. IT IS THE OWNER'S INTENT TO PERFORM A REHABILITATION OF IDENTIFIED

EXTERIOR CLADDING, WINDOWS, DOORS, AND ROOF AREAS AS

DESIGNATED FOR EACH EXISTING BUILDING AS ONE SINGLE PHASE OF

WORK. CONTRACTOR SHALL COORDINATE WITH THE OWNER FOR

SCHEDULE, PHASING, AND WORK.

3. BUILDING REHABILITATION MAY NOT OCCUR IN NUMERICAL ORDER AS

RELATED TO SITE LAYOUT OR BUILDING DESIGNATION.

4. REFER TO THE SITE PLAN AND PROJECT MANUAL FOR NOTES, ASSUMED

LIMITS OF WORK, AND FULL SUMMARY OF WORK.

PROJECT CODE ANALYSIS: PROJECT DESCRIPTION:

1. THE OREGON DEPARTMENT OF FORESTRY ASTORIA DISTRICT CAMPUS IN

ASTORIA OREGON IS A COMPOUND OF SEVEN (7) FACILITY OPERATIONS

BUILDINGS. BUILDINGS WITHIN THE COMPOUND HAVE VARIED YEARS OF

DEVELOPMENT WITH LIMITED DOCUMENTATION RELATING TO ORIGINAL

DESIGN AND CONSTRUCTION. BUILDING ENCLOSURE WORK FOR THIS

PROJECT ARE PRIMARILY DESIGNATED FOR THE MAIN OFFICE BUILDING

HOWEVER EACH BUILDING SHALL RECEIVE IDENTIFIED WORK AS PART OF

THE PROPOSED SCOPE.

2. BUILDING A: MAIN OFFICE - ELEVATIONS ARE SIMILAR IN ASSEMBLY

CONFIGURATIONS, AND ARE PREDOMINANTLY VARIED BY FLOOR LEVEL

ACCESS, SIDING MATERIALS, AND ROOF CONFIGURATION. OF NOTE THE

OFFICE BUILDING UNDERWENT AN EXPANSION AROUND THE YEAR 1997

WHICH INCLUDED A FIRE-RATED AREA SEPARATION WALL BETWEEN THE

ORIGINAL OFFICE BUILDING AND THE NEW OFFICE ADDITION. BUILDING

COMPONENTS ARE A COMBINATION OF HARDBOARD "MASONITE"

COMPOSITE LAP SIDING WITH METAL CORNER CLOSURE PIECES ON THE

ORIGINAL STRUCTURE AND FIBER CEMENT PLANK LAP SIDING AND TRIM

ON THE ADDITION. TRIM VARIES WITH BOTH FIBER CEMENT AND WOOD

FENESTRATION TRIM MEMBERS. THE BUILDING ROOF AREAS ARE PITCHED

ROOF AND GABLE CONFIGURATIONS WITH OVERHANGS AND ARE CLAD IN

COMPOSITION ASPHALT SHINGLE ROOFING.

2.1. THE PROPOSED BUILDING ENCLOSURE REHABILITATION SHALL

CONSIST OF REMOVAL, DISPOSAL, AND REPLACEMENT ALL EXISTING

SIDING AND TRIM ALONG EACH BUILDING ELEVATION AND INCLUDE

CONCEALED WRB AND FLASHINGS. REMOVAL, DISPOSAL, AND

REPLACEMENT OF ALL EXISTING WINDOW UNITS. REMOVAL AND

REINSTALLATION OF ALL EXISTING SWING DOOR UNITS. REMOVAL,

DISPOSAL, AND REPLACEMENT OF 100% OF EXISTING ROOF

CLADDINGS INCLUDING UNDERLAYMENT AND FLASHINGS. EXISTING

GUTTERS AND DOWNSPOUTS TO BE REMOVED AND REINSTALLED.

100% REMOVAL AND REPLACEMENT OF (2) LAYERS OF GYPSUM

WALLBOARD SHEATHING AT ABOVE ROOF AREAS OF RATED

PARTITION WALL (TYPICAL EACH SIDE) .

3. BUILDING B AND C: MECHANIC'S SHOP - ELEVATIONS ARE SIMILAR IN

ASSEMBLY COMPONENTS AND CONSIST OF FIBER CEMENT PLANK LAP

CLADDING AND TRIM, FLANGED VINYL WINDOWS, METAL CLAD SWING

DOORS, AND COMPOSITION ASPHALT SHINGLE ROOFING ASSEMBLIES

WITH METAL FLASHINGS.

3.1. THE PROPOSED BUILDING ENCLOSURE REHABILITATION SHALL

CONSISTS TARGETED REPAIR WORK TO THE EXISTING ROOF

ASSEMBLY AND MAY INCLUDE REMOVAL AND REPLACEMENT OF

EXISTING ASPHALT SHINGLE ROOFING AND FLASHING COMPONENTS.

4. BUILDING D: PUMPER SHED - ELEVATIONS ARE SIMILAR IN ASSEMBLY

COMPONENTS AND CONSIST OF A COMBINATION OF T1-11 PLYWOOD

SIDING AND FIBER CEMENT PLANK LAP CLADDING, (1) FLANGED ALUMINUM

AND (1) VINYL WINDOW ASSEMBLY, TRANSLUCENT FIBERGLASS AND

METAL ROLL UP DOOR ASSEMBLIES, AND COMPOSITION ASPHALT SHINGLE

ROOFING ASSEMBLIES WITH METAL FLASHINGS.

4.1. THE PROPOSED BUILDING ENCLOSURE REHABILITATION SHALL

CONSIST OF REMOVAL, DISPOSAL, AND REPLACEMENT OF ALL ROOF

CLADDINGS INCLUDING UNDERLAYMENT, FLASHINGS, GUTTERS AND

DOWNSPOUTS.

5. BUILDING E: OLD PRESERVATION BUILDING - ELEVATIONS ARE SIMILAR IN

ASSEMBLY COMPONENTS AND CONSIST OF FIBER CEMENT SIDING, LIMITED

PROTECTED AREAS OF T1-11, CEDAR TRIMS AND MOUNTING BLOCKS,

PANEL CLAD WOOD DOORS, METAL ROLL UP DOOR, AND COMPOSITION

ASPHALT SHINGLE ROOFING ASSEMBLIES WITH METAL FLASHINGS.

5.1. THE PROPOSED BUILDING ENCLOSURE REHABILITATION SHALL

CONSISTS TARGETED REPAIR WORK TO THE EXISTING ROOF

ASSEMBLY AND MAY INCLUDE REMOVAL AND REPLACEMENT OF

EXISTING ASPHALT SHINGLE ROOFING AND FLASHING COMPONENTS..

GENERAL NOTES: GENERAL NOTES, CONT.:

1. READ DESIGN DOCUMENTS (DRAWINGS) IN CONJUNCTION WITH THE

PROJECT MANUAL (PRODUCT SPECIFICATIONS).

2. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS ON SITE.

3. DRAWINGS OF ELEVATIONS AND SITE PLANS OF THE PROJECT ARE

REPRODUCED FROM BASE DRAWINGS PREPARED BY ORIGINAL

ARCHITECT. BRING DISCREPANCIES BETWEEN DESIGN DOCUMENTS AND

ACTUAL PROJECT CONDITIONS TO THE IMMEDIATE ATTENTION OF THE

BUILDING ENVELOPE CONSULTANT AND REQUEST A REVIEW.

4. EXECUTION OF THE CONTRACT BY THE CONTRACTOR IS A

REPRESENTATION THAT THE CONTRACTOR HAS VISITED THE SITE,

BECOME GENERALLY FAMILIAR WITH THE LOCAL CONDITIONS UNDER

WHICH THE WORK IS TO BE PERFORMED AND CORRELATED PERSONAL

OBSERVATIONS WITH REQUIREMENTS OF THE CONTRACT DOCUMENTS.

5. ALL WORK TO BE PERFORMED UNDER THIS SCOPE OF REPAIRS (WORK)

SHALL BE CONDUCTED IN FULL COMPLIANCE WITH ALL APPLICABLE

LOCAL, STATE, AND FEDERAL LAWS AND REGULATIONS. IT IS THE

CONTRACTOR'S DUTY TO BE FAMILIAR WITH ALL SUCH APPLICABLE

LOCAL, STATE, AND FEDERAL LAWS AND REGULATIONS. FURTHERMORE,

THE CONTRACTOR SHALL ENSURE THAT ALL ACTIVITIES PERFORMED BY

THE CONTRACTOR'S PERSONAL EMPLOYEES, SUBCONTRACTORS, AND

SUPPLIERS COMPLY WITH THESE LAWS AND REGULATIONS DURING THE

CONSTRUCTION PROCESS.

6. CONTRACT DRAWINGS ARE COMPLIMENTARY, AND WHAT IS REQUIRED

BY ANY ONE SHALL BE BINDING AS IF REQUIRED BY ALL. BEFORE

STARTING EACH PORTION OF THE WORK, CAREFULLY STUDY AND

COMPARE THE VARIOUS DRAWINGS AND OTHER CONTRACT DOCUMENTS

RELATIVE T0 THAT PORTION OF THE WORK, AS WELL AS INFORMATION

FURNISHED BY OWNER. TAKE FIELD MEASUREMENTS OF ANY EXISTING

CONDITIONS RELATED TO THAT PORTION OF THE WORK AND OBSERVE

CONDITIONS AT THE SITE AFFECTING IT. THESE OBLIGATIONS ARE FOR

THE PURPOSE OF FACILITATING CONSTRUCTION BY THE CONTRACTOR

AND NOT FOR THE PURPOSE OF DISCOVERING ERRORS, OMISSIONS, OR

INCONSISTENCIES IN THE CONTRACT DOCUMENTS; HOWEVER, REPORT

ERRORS, OMISSIONS, OR INCONSISTENCIES DISCOVERED BY THE

CONTRACTOR PROMPTLY TO THE CONSULTANT AS A REQUEST FOR

INTERPRETATION IN THE FORM PROVIDED IN THE PROJECT MANUAL.

7. REPORT DISCREPANCIES IN CONTRACT DOCUMENTS TO FORENSIC FOR

CLARIFICATION PRIOR TO COMMENCING WORK.

8. IMMEDIATELY NOTIFY BUILDING ENVELOPE CONSULTANT UPON

DISCOVERY OF ADDITIONAL UNFORESEEN DAMAGE TO EXISTING

CONSTRUCTION SCHEDULED TO REMAIN AND THAT IS OUTSIDE THE

CONTRACT. REQUEST A REVIEW. DO NOT COMMENCE RELATED WORK

TO NEARBY WORK WITHOUT CONSULTANT APPROVAL.

9. TRADE CONTRACTORS ARE RESPONSIBLE FOR THE LAYOUT OF THEIR

OWN WORK, AND TO SEE THAT ITS WORK COMES TOGETHER WITH THAT

OF OTHERS. REPORT DISCREPANCIES ON DRAWINGS TO BUILDING

ENVELOPE CONSULTANT FOR DECISIONS.

10. TRADE CONTRACTORS MUST ASSURE THEMSELVES THAT THEY HAVE

THE LATEST DRAWINGS ISSUED FOR CONSTRUCTION, SPECIFICATIONS,

MANUFACTURERS' INSTALLATION INSTRUCTIONS AND REFERENCE

STANDARDS IN THE CONTRACTOR'S OFFICE.

11. DURING REMEDIATION WORK, THE CONTRACTOR IS TO VERIFY AND

MAINTAIN RATED WALL ASSEMBLIES AT ALL EXISTING WALL LOCATIONS.

OVERSIGHT IS REQUIRED BY A LICENSED STRUCTURAL ENGINEER TO

PROVIDE FRAMING AND SHEATHING CONDITIONS ASSESSMENT

INCLUDING RATED WALLS WHERE REPAIR WORK IS IDENTIFIED DURING

ACTUAL WORK ON THE PROJECT. THE CONTRACTOR IS TO PROVIDE

AREA SPECIFIC ENGINEERED DRAWINGS SHOWING EXTENT, DETAILS,

AND CALCULATIONS TO THE AUTHORITY HAVING JURISDICTION FOR

REVIEW AND APPROVAL PRIOR TO REMEDIATION WORK.

CONCEALED BARRIER INSTALLATION:

1. CLEAN AND PREPARE SURFACES PRIOR TO INSTALLATION OF ALL

MEMBRANES IN ACCORDANCE TO PRODUCT MANUFACTURERS'

RECOMMENDATIONS AND AS DIRECTED BY BUILDING ENCLOSURE

CONSULTANT.

2. CONTRACTOR TO PROVIDE ISOMETRIC FLEXIBLE SADDLE

FLASHINGS AT MULTI-PLANE WALL, WALL OPENING, ROOF

TRANSITION, AND DECK TRANSITION AREAS AS OCCURS AND AS

DETAILED PER DESIGN DOCUMENTS.

MEMBRANE INSTALLATION:

1. SEAL WEATHER-RESISTIVE BARRIER AT ALL LAPS AND

TERMINATIONS TO CREATE AIR BARRIER. NOT ALL SEALANT

LOCATIONS ARE ILLUSTRATED.

2. PROVIDE FURRING STRIPS/RAIN SCREEN BEHIND ALL EXTERIOR

CLADDING AND TRIM IN ACCORDANCE WITH THE DRAWINGS,

SPECIFICATIONS, AND MANUFACTURER'S WRITTEN

INSTRUCTIONS.

METAL FLASHING:

1. PROVIDE AND INSTALL METAL HEAD FLASHING WITH FOLDED,

UPTURNED END DAMS OVER WINDOW, DOOR, AND SLIDING

GLASS DOORS TRIM. CONTRACTOR TO FIELD VERIFY THAT METAL

HEAD FLASHING DOES NOT INTERFERE WITH OPERATION OF THE

FENESTRATION.

2. FORM 100% OF THROUGH-WALL AND HEAD FLASHINGS WITH A

SLOPED HORIZONTAL SURFACE CONFORMING TO THE

FOLLOWING CRITERIA:

· ENSURE A 5% SLOPE AT GREATER THAN OR EQUAL TO A

1-1/2" WIDE HORIZONTAL SURFACE

· ENSURE A 10% SLOPE AT LESS THAN A 1-1/2" WIDE

HORIZONTAL SURFACE

3. CONTRACTOR TO PROVIDE 3-DIMENSIONAL METAL SADDLE

FLASHINGS AT MULTI-PLANE SUBSTRATE INTERSECTIONS, ROOF

TRANSITIONS, WALLS TRANSITIONS, DECK TRANSITIONS, AND AT

OTHER SIMILAR LOCATIONS AS OCCURS AND AS DETAILED PER

DESIGN DOCUMENTS.

EXTERIOR OPENINGS AND PENETRATIONS:

1. ALL SCHEDULES AND QUANTITIES OF WINDOWS, DOORS, VENT

PENETRATIONS, AND EXTERIOR FIXTURES, SUCH AS LIGHT

FIXTURES, CONVENIENCE RECEPTACLES, EXHAUST VENTS, PIPE

PENETRATIONS, HOSE BIBBS, ELECTRICAL OR METERS, ETC.,

THAT HAVE BEEN PROVIDED IN THE DOCUMENTS ARE

APPROXIMATE AND MUST BE VERIFIED BY THE CONTRACTOR ON

SITE. CONTRACTOR SHALL PERFORM OWN QUANTITY SURVEY

AND VERIFIED QUANTITIES OF ALL ITEMS INDICATED IN THE

DRAWINGS.

2. SEAL EXTERIOR WALL PENETRATIONS FOR AIR BARRIER

CONTINUITY WITH SCHEDULED MINIMALLY EXPANDING FOAM

INSULATION.

3. FORM EXTERIOR PERIMETER DYNAMIC SEALANT JOINTS, 1/2"

WIDE TYPICAL, WITH CONTINUOUS CLOSED CELL BACKER ROD

U.O.N., ENSURE BACKER ROD DIAMETER EXCEEDS JOINT WIDTH

BY 25% AND MAINTAIN A JOINT WIDTH-TO-DEPTH RATIO OF 2:1.

GENERAL NOTES, CONT.:

DRAWING TERMS:

1. DEMOLISH: (DEMO) TO COMPLETELY REMOVE AND LEGALLY

DISPOSE OF OFF-SITE IN A MANNER COMPLIANT WITH FEDERAL,

STATE, AND LOCAL PROTOCOLS.

2. SCHEDULED (ITEM): COMPONENTS CALLED OUT AS SCHEDULED

SHALL REMAIN IN PLACE, BE REMOVED AND REINSTALLED, BE

REMOVED AND REPLACED, BE INSTALLED AS A NEW

COMPONENT, OR REPLACED IF DAMAGED IS DISCOVERED.

REFER TO PROJECT MANUAL FOR CONDITION, ASSEMBLIES, AND

RELATED MATERIALS.

3. PROTECT (ITEM): A TERM USED ON DRAWINGS TO INDICATE AN

ITEM REQUIRES PROTECTION FROM THE WORK.

4. REMOVE (ITEM): A TERM USED ON DRAWINGS TO INDICATE A

SPECIFIC ITEM TO BE DETACHED FROM EXISTING CONSTRUCTION

AND LEGALLY DISPOSED OF OFF-SITE, UNLESS INDICATED

OTHERWISE TO BE REMOVED, SALVAGED, AND REINSTALLED.

5. REMOVE AND REINSTALL (ITEM): A TERM USED ON DRAWINGS TO

INDICATE A SPECIFIC ITEM TO BE DETACHED FROM EXISTING

CONSTRUCTION, PREPARED FOR REUSE, AND REINSTALLED

BACK IN ITS EXISTING LOCATION.

6. RELOCATE (ITEM): A TERM USED IN DRAWINGS TO INDICATE AN

EXISTING ITEM THAT HAS BEEN REMOVED, AND TO BE

REINSTALLED IN A NEW LOCATION

7. SALVAGE (ITEM): CAREFULLY DETACH FROM EXISTING

CONSTRUCTION, IN A MANNER TO PREVENT DAMAGE READY FOR

REUSE. INCLUDE FASTENERS OR BRACKETS NEEDED FOR

REATTACHMENT IN ORIGINAL LOCATION OR ELSEWHERE.

8. EXISTING TO REMAIN (ITEM): A TERM USED ON DRAWINGS TO

INDICATE EXISTING ITEMS OF CONSTRUCTION THAT ARE NOT BE

REMOVED AND THAT ARE NOT OTHERWISE INDICATED TO BE

REMOVED, SALVAGED, OR REMOVED AND REINSTALLED.

EXISTING TO REMAIN IS INDICATED BY GRAPHIC LINETYPE

SYMBOL.

9. PHASE: A PORTION OF THE WORK TO BE COMPLETED DURING A

SET PERIOD OF TIME, AS DEFINED IN THE PROJECT

SPECIFICATIONS.

10. REFER TO SPECIFICATIONS SUMMARY OF WORK, GENERAL

DESCRIPTION OF WORK, FOR SCOPE OF REPAIR ASSEMBLIES.

ALUM. ALUMINUM

APPROX. APPROXIMATE

ARCH. ARCHITECTURAL

BLDG. BUILDING

BOT BOTTOM

COL. COLUMN

CONC. CONCRETE

CONT. CONTINUOUS

CONST. CONSTRUCTION

C/W COMPLETE WITH

DIA. DIAMETER

DEFS DIRECT-APPLIED

FINISH SYSTEM

DIM. DIMENSION

DWG DRAWING

DS DOWNSPOUT

E. EAST

EA. EACH

ELEV. ELEVATION

ELEC. ELECTRICAL

EIFS EXTERIOR INSULATION &

FINISH SYSTEM

EQ. EQUAL

EQUIP. EQUIPMENT

EXIST. EXISTING

EXT. EXTERIOR

FC FIBER CEMENT

FIN. FINISH

ABBREVIATIONS:

F.O.S. FACE OF STUD

FLR. FLOOR

FRTW FIRE-RETARDANT

TREATED WOOD

FURR FURRING OR FURRED

GA GAUGE

GALV. GALVANIZED

GWB GYPSUM WALL BOARD

GYP. GYPSUM

HORIZ. HORIZONTAL

INT. INTERIOR

INSUL. INSULATION

MAX MAXIMUM

MEMB. MEMBRANE

MTL METAL

MIN. MINIMUM

MISC. MISCELLANEOUS

N. NORTH

N.I.C. NOT IN CONTRACT

(NOT IN SCOPE)

NTS NOT TO SCALE

O.C. ON CENTER

PLY PLYWOOD

P.T. PRESSURE TREATED (POST-TENSIONED

WHEN USED WITH CONCRETE)

R RADIUS

REF. REFERENCE

REINF REINFORCED

REQ'D REQUIRED

RD ROOF DRAIN

S. SOUTH

SAM SELF ADHESIVE

MEMBRANE (FLASHING)

SECT. SECTION

SIM. SIMILAR

SPEC SPECIFICATION

S.S. STAINLESS STEEL

STRUCT. STRUCTURAL

T&G TONGUE AND GROOVE

TBD TO BE DETERMINED

TEMP TEMPERATURE

T.O.W. TOP OF WALL

TYP. TYPICAL

U.O.N. UNLESS OTHERWISE NOTED

VERT. VERTICAL

V.I.F. VERIFY IN FIELD

W. WEST

W/ WITH

W/O WITHOUT

WRB WEATHER-RESISTIVE

BARRIER

GYPSUM SHEATHING / GYPSUM WALLBOARD

BATT INSULATION

DETAIL HATCH PATTERN LEGEND:

TYPICAL LINE WEIGHT OF 'NEW' BUILDING ENVELOPE

COMPONENTS - WALLS, WINDOWS, DOORS, ETC.

SAM - SELF APPLIED MEMBRANE FLEXIBLE FLASHING,

OR MANUFACTURED FLASHING PANELS AS NOTED

WRB - WEATHER RESISTIVE BARRIER

MISC. COMPONENTS - DRAINAGE MAT, REINFORCING

MESH, BUG SCREEN, FASTENERS, SCREWS, NAILS

EXISTING ROOF UNDERLAYMENT, OTHER EXISTING

COMPONENTS

METAL FLASHING

SEALANT / ADHESIVE LAYER

LINETYPE LEGEND:

FIBER CEMENT CLADDING / CEMENT

BOARD / TILE ADHESIVE

CONCRETE

DECK COATING REINFORCEMENT MESH

DRAINAGE MAT

ACRYLIC REINFORCED CEMENTITIOUS DECK

COATING SYSTEM

POLYURETHANE DECK COATING / CONCRETE

DAMP-PROOFING

RIGID INSULATION / FOAM

STEEL / METAL

SCHEDULED WRB

SCHEDULED SAM

METAL FLASHING, COPING, AND SADDLES

APPLIED DECK COATING SYSTEM

SCHEDULED SEALANT

ISOMETRIC DETAIL HATCH PATTERN LEGEND:

TYPICAL LINE WEIGHT OF EXISTING BUILDING

ENVELOPE COMPONENTS

DYNAMIC SEALANT JOINT: SEALANT APPLIED OVER

CLOSED CELL BACKER ROD (2:1 RATIO)

CONTINUOUS SEALANT BEAD

PLYWOOD SHEATHING

PROJECT TEAM:

Buildings D, E, F, & G - Easterly View

PROJECT PARAMETERS:

1. UNLESS ACCOMPANIED BY DOCUMENTATION STAMPED BY A LICENSED

PROFESSIONAL, THE WORK DESCRIBED WITHIN THESE CONTRACT

DOCUMENTS SHALL NOT INCLUDE THE FOLLOWING CRITERIA (REFER TO

ORS 671.030d):

· THE STRUCTURAL PART OF THE BUILDING, INCLUDING BUT NOT

LIMITED TO THE FOUNDATION WALLS, FLOORS, ROOF, FOOTINGS,

BEARING PARTITIONS, BEAMS, COLUMNS AND JOISTS, IS NOT

INVOLVED;

· THE BUILDING CODE CLASSIFICATION BY USE OR OCCUPANCY OF

THE BUILDING IS NOT CHANGED; AND

· THE BUILDING CODE CLASSIFICATION BY TYPE OF CONSTRUCTION

OF THE BUILDING IS NOT CHANGED.

2. NON-STRUCTURAL WORK DESCRIBED WITHIN THESE CONTRACT

DOCUMENTS SHALL FALL UNDER EXCEPTIONS: 2 OF OSSC 107.1IN THAT

PLANS, SPECIFICATIONS, CALCULATIONS, DIAGRAMS AND OTHER DATA

PREPARED AND DESIGNED BY AN ENGINEER OR ARCHITECT LICENSED

BY THE STATE TO PRACTICE AS SUCH ARE NOT REQUIRED FOR THE

FOLLOWING WORK:

· 2.3 ALTERATIONS OR REPAIRS THAT DO NOT INVOLVE THE

STRUCTURAL PARTS OF THE BUILDING.

3. IT IS RECOGNIZED THAT THERE MAY BE SEPARATE TRADE PERMITS

RELATED TO PLUMBING OR UTILITY EXTENSIONS AND/OR MINOR

RECONFIGURATIONS OF EXTERIOR VENTILATION AND ELECTRICAL

PENETRATIONS RELATED TO THIS REHABILITATION PROJECT. IT IS

UNLIKELY THAT MECHANICAL AND/OR FIRE LIFE SAFETY SYSTEMS

INCLUDING ALARMS OR FIRE SPRINKLER SYSTEMS WILL BE AFFECTED.

CLIENT:

Oregon Department of Forestry 2600 State Street Salem, OR 97310 Contact: Joseph Pfau Phone: 503.507.1527 email: joseph.j.pfau@odf.oregon.gov

BUILDING ENVELOPE CONSULTANT:

Forensic Building Consultants 12901 SE 97th Ave., Suite 310 Clackamas, OR 97015 Phone: 503.772.1114 Contact: Jordon Wyatt, Project Manager email: jordon@forensicbuilding.com

Michael Green, Technical Design Manager email: michaelg@forensicbuilding.com

AUTHORITY HAVING JURISDICTION:

Clatsop County Building Permits 800 Exchange St., Ste. 100 Astoria, OR 97103 Building and Inspections: 503.338.3697 email:BuildingDivision@clatsopcounty.gov https://www.clatsopcounty.gov/building

Building D: Tanker/Engine Garage/Workshop - South Elevation View Building A: Main Office Building - East Elevation View

CONTRACTOR:

92219 OR-202 Astoria, OR 97103

PROJECT BASIS OF DESIGN

1. PROJECT BASE BID SCOPE OF REPAIR WORK COMPONENTS TO INCLUDE

THE FOLLOWING AREAS OF WORK:

· REMOVE AND DISPOSE OF HARDBOARD AND FIBER CEMENT

WALL CLADDING COMPONENTS

· REMOVE AND DISPOSE OF VINYL WINDOW ASSEMBLIES

· REMOVE AND STORE SWING DOOR ASSEMBLIES

· REMOVE AND DISPOSE OF ASPHALT SHINGLE ROOFING

· REMOVE AND DISPOSE OF METAL PARAPET COPING

· REMOVE AND DISPOSE OF EXPOSED PORTIONS OF EXISTING

MASONRY BRICK CHIMNEY, BOILER VENT STACK, AND

ASSOCIATED FLASHING COMPONENTS

2. SCHEDULED PROJECT COMPONENTS INCLUDE, BUT ARE NOT LIMITED TO:

· WOOD FRAMING AND FURRING MEMBERS

· BATT, FOAM, AND CELLULOSE INSULATION (TO MATCH

EXISTING)

· PLYWOOD AND GYPSUM WALLBOARD SHEATHING

· CODE COMPLIANT WEATHER-RESISTIVE BARRIER (WRB)

AND FLEXIBLE SAM FLASHING

· FIBER CEMENT PLANK LAP CLADDING, TRIM MEMBERS, AND

MOUNTING BLOCKS

· FLANGED VINYL WINDOWS

· ALUMINUM GUTTERS AND DOWNSPOUTS

· METAL PARAPET COPING, TRANSITION FLASHING, AND

THREE-DIMENSIONAL METAL SADDLE FLASHINGS

· SCHEDULED SEALANTS

· EXTERIOR PAINTING

PROJECT DESCRIPTION CONT.:

6. BUILDING F: REFORESTATION WAREHOUSE - ELEVATIONS ARE SIMILAR IN

ASSEMBLY COMPONENTS AND CONSIST OF FIBER CEMENT SIDING,

CEDAR TRIMS AND MOUNTING BLOCKS, (1) METAL ROLL UP DOOR, AND

COMPOSITION ASPHALT SHINGLE ROOFING ASSEMBLIES WITH METAL

FLASHINGS.

6.1. THE PROPOSED BUILDING ENCLOSURE REHABILITATION SHALL

CONSISTS TARGETED REPAIR WORK TO THE EXISTING ROOF

ASSEMBLY AND MAY INCLUDE REMOVAL AND REPLACEMENT OF

EXISTING ASPHALT SHINGLE ROOFING AND FLASHING

COMPONENTS.

7. BUILDING G: PROTECTION WAREHOUSE/OFFICE - ELEVATIONS ARE

SIMILAR IN ASSEMBLY COMPONENTS AND CONSIST OF A COMBINATION

OF T1-11 PLYWOOD SIDING AND FIBER CEMENT PLANK LAP CLADDING, (1)

FLANGED ALUMINUM WINDOW ASSEMBLY, METAL ROLL UP DOOR

ASSEMBLIES, PANEL CLAD SWING DOOR UNITS, AND COMPOSITION

ASPHALT SHINGLE ROOFING ASSEMBLIES WITH METAL FLASHINGS.

7.1. THE PROPOSED BUILDING ENCLOSURE REHABILITATION SHALL

CONSISTS TARGETED REPAIR WORK TO THE EXISTING ROOF

ASSEMBLY AND MAY INCLUDE REMOVAL AND REPLACEMENT OF

EXISTING ASPHALT SHINGLE ROOFING AND FLASHING

COMPONENTS.

8. BUILDING H: CHEMICAL STORAGE WAREHOUSE - ELEVATIONS ARE

SIMILAR IN ASSEMBLY COMPONENTS AND CONSIST OF A COMBINATION

OF T1-11 PLYWOOD SIDING, FIBER CEMENT PLANK LAP CLADDING, AND

TRANSLUCENT FIBERGLASS PANELS, (2) FLANGED ALUMINUM WINDOW

ASSEMBLY, (2) METAL ROLL UP DOOR ASSEMBLIES, (2) PANEL CLAD

SWING DOOR UNITS, AND COMPOSITION ASPHALT SHINGLE ROOFING

ASSEMBLIES WITH METAL FLASHINGS.

8.1. THE PROPOSED BUILDING ENCLOSURE REHABILITATION SHALL

CONSIST OF REMOVAL, DISPOSAL, AND REPLACEMENT OF ALL ROOF

CLADDINGS INCLUDING UNDERLAYMENT, FLASHINGS, GUTTERS AND

DOWNSPOUTS.

A0.00

COVER SHEET

CODE ANALYSIS

PROJECT DESCRIPTION

05.14.2025

SHEET NAME

REVISIONS

ISSUE

REV. DATE

PROJECT NAME

CLIENT

PROJECT NUMBER

SHEET NUMBER

15 82nd Drive, Suite 10 Gladstone, OR 97027

TEL: 503.772.1114

FAX: 503.772.4039

www.forensicbuilding.com info@forensicbuilding.com

COPYRIGHT ©2025 FORENSIC

BUILDING CONSULTANTS

All Rights Reserved

PRINT ALL DETAILS IN

COLOR AT 24x36

OR CCB# 155496

WA FORENW C94308

UT #8334529-5501

(RE) 25-062

Permit Issue Set

Bidding Issue Addenda - 06.26.2026

O re go n

D ep ar tm en t o f F or es try

A st or ia

D is tri ct

B ui ld in g

- R oo f a nd S id in g R eh ab ili ta tio n

(P O

-6

-0

8)

O re go n

De pa rtm en t o f F or es try

S ta te

S tre et , B ui ld in g

F, S al em

, O R

O

R -2

A st or ia , O

R

2 BUILDING 'B' AND 'C' ROOF PLAN

1/8" = 1'-0" mhg

ROOF PLAN KEYNOTES:

ROOF PLAN NOTES:

1. COORDINATE ROOF DEMOLITION WITH SCHEDULED WORK AT ADJACENT EXTERIOR WALL CLADDING

INTEGRATION WORK PER THE DESIGN DOCUMENTS AND ACCOMPANYING PROJECT MANUAL. PERFORM

SELECTIVE AND LIMITED DEMOLITION OF EXISTING WALL ASSEMBLIES AS REQUIRED.

2. VERIFY CLEARANCE REQUIREMENTS AND MATCH ASSEMBLY OF EXISTING FIRE RATED WALLS AND ROOF

SYSTEMS WHERE REPAIRED DURING THE COURSE OF REQUIRED WORK.

3. REPLACE EXTERIOR PLYWOOD AND GYPSUM WALLBOARD SHEATHING AS NECESSARY TO PERFORM REQUIRED WORK AND AS NECESSARY TO CHASE DAMAGE TO EXTINCTION. PATCH, REPAIR, AND MATCH

PLANE OF EXISTING ADJACENT SURFACES.

4. PLANS HAVE BEEN CREATED USING INFORMATION REPRODUCED FROM INFORMATION ACQUIRED FROM PUBLIC RECORD, THIRD PARTY DATA SETS, AND/OR PREPARED BY ORIGINAL/PREVIOUS ARCHITECT, DESIGNER, AND/OR CONSULTANT. PLANS ARE FOR REFERENCE TO EXISTING CONDITIONS, WALL LOCATIONS, AND FENESTRATIONS ONLY. BRING ANY DISCREPANCIES BETWEEN DESIGN DOCUMENTS AND ACTUAL PROJECT CONDITIONS TO THE IMMEDIATE ATTENTION OF THE BUILDING ENCLOSURE CONSULTANT AND

REQUEST A REVIEW.

5. CONTRACTOR TO VERIFY VENTILATION OF EXISTING BUILDING ATTIC AREA FOR VENTILATION REQUIREMENTS.

INSTALL ADDITIONAL INTAKE AT EAVE AND UPPER ROOF EXHAUST LOCATIONS AS REQUIRED.

6. CONTRACTOR SHALL MAKE REQUIRED REPAIRS TO EXISTING RATED DRAFT STOP ASSEMBLIES TO ENSURE

CONTINUOUS FIRE RATING FOR EACH EXISTING ATTIC AREA.

ROOF PLAN LEGEND:

REMOVE AND DISPOSE OF 100% OF EXISTING COMPOSITION ASPHALT SHINGLE

ROOFING, UNDERLAYMENT, STATIC VENTS, EXHAUST VENTS, AND ASSOCIATED ROOF

AND FLASHING COMPONENTS. INSTALL SCHEDULED COMPOSITION ASPHALT SHINGLE

ROOFING, UNDERLAYMENT, AND ASSOCIATED COMPONENTS PER DESIGN DOCUMENT

ROOF DETAILS AND PROJECT MANUAL.

INSTALL SCHEDULED ROOF GUTTERS AT ROOF EAVE LOCATIONS WITH DOWNSPOUTS

AND CLEANOUT LOCATED TO TIE INTO EXISTING SITE STORM SEWER LOCATIONS.

REFER TO DESIGN DOCUMENT PACKAGE AND PROJECT MANUAL.

STATIC STEMMED ROOF VENT ASSEMBLY, CONTRACTOR TO ACCOUNT FOR TIGHT-LINING

100% OF BUILDINGS BATH AND KITCHEN LOCATIONS AS OCCURS, REFER TO DETAIL 3/A5.02

PLUMBING VENT STACK ASSEMBLY, REFER TO DETAIL 1/A5.03

SCHEDULED CONTINUOUS RIDGE VENT, REFER TO DETAIL 8/A5.01

APPROXIMATE LOCATION OF STEMMED STATIC ROOF VENT PENETRATION.

EXISTING ROOF SLOPE TO REMAIN.

APPROXIMATE LOCATION OF BOILER EXHAUST STACK PENETRATION.

APPROXIMATE LOCATION OF PLUMBING STACK VENT PENETRATION.

APPROXIMATE LOCATION OF CONTINUOUS RIDGE EXHAUST VENT.

BOILER VENT STACK ASSEMBLY, REFER TO DETAIL 5/A5.02.

1 BUILDING 'A' ROOF PLAN

1/8" = 1'-0" mhg

N

N

APPROXIMATE LOCATION OF TURBINE VENT PENETRATION.

A5.01 TYP.

A5.01 TYP. 1

A3.03

A5.01 TYP.

A5.01 TYP.

A3.03

A5.01TYP.

A3.06 8

A5.01TYP.

A5.02

A5.03

A5.01TYP.

A5.01 TYP.

A5.01 SIM.

A5.--SIM.

A5.01SIM.

A5.01 SIM.

A5.01TYP.

A5.01TYP.

A5.01TYP.

SIM.

2 TYP.

1 TYP.

1 TYP.

2 TYP.

1 TYP.2 TYP.

2TYP.

1TYP.

TYP.

ANTENNA POLE ASSEMBLY AND 3-POINT GUY-WIRE ATTACHMENT, REFER TO VENT PIPE

PENETRATION DETAIL 1/A5.03 FOR SIMILAR (POST BASE) INTEGRATION AND TO DETAIL

7/A5.04 (GUY ANCHOR).

TYP.

A5.02

A5.02

A5.021

A5.02

A3.04

SIM.

A5.04 TYP.

A5.02TYP.

A5.02

A5.02

4'-0" 4'-0"

A5.02 1

A5.02

A5.01 BELOW

A5.04

A5.04SIM.

A5.04TYP.

TARGETED ROOF REHABILITATION AND REPAIRS AT IDENTIFIED LOCATIONS TO BE DETAILED IN SIMILAR FASHION TO CONDITIONS FOR THE FULL ROOFING REPLACEMENT OCCURRING AT BUILDING 'A'. REFER

TO DESIGN PACKAGE FOR RELATED DETAILS AND CORRELATING CONDITIONS.

SIM.

A5.02

SIM. AS

NEEDED

DS APPROXIMATE LOCATION OF EXISTING DOWNSPOUT, CLEANOUT, AND STORM

SEWER TIE-IN OR DAYLIGHT TO GRADE.

DS DSDSDSDS

DSDS

DS

DS

DS DS

DS

DS DS

DS

DSDSDS

DS

DS DS

DS DS

A5.03

SIM. AS

NEEDED

ROOF ANCHOR FALL PROTECTION, REFER TO DETAIL 1/A5.01.

FP

8 NOT USED

9 PROPOSED FALL PROTECTION ROOF ANCHOR , REFER TO DETAIL 7/A5.04. LOCATE

12'-0" O.C. MAX. TYPICAL, EQ. DISTANCE FROM RIDGE ENDS, AND 4'-0" LATERAL

DISTANCE FROM ADJACENT RIDGE.

FP FP FP FP FP FP FP FP FP FP FP

12'-0" O.C. TYP.

EQ.

9TYP.

12'-0" O.C. TYP.

EQ.

9 TYP.

4'- 0"

4'- 0"

FP FP

12'-0" O.C. TYP.

EQ.

4'- 0"

FPFPFPFP

TYP.

ESTIMATED ROOF WORK AT BUILDING 'B & C' SHALL INCLUDE:

· ASSUME REMOVAL AND REPLACEMENT OF 200 SQUARE FEET OF COMPOSITION ASPHALT

SHINGLE ROOFING AND UNDERLAYMENT, MATCHING EXISTING STYLE AND COLOR.

· ASSUME REMOVAL AND REPLACEMENT OF 128 SQUARE FEET OF EXISTING PLYWOOD

ROOF DECK SHEATHING. INSTALLED SHEATHING SHALL BE 5/8" CDX PLYWOOD.

· REPLACEMENT OF WEATHERPROOF FLASHING COLLARS/GASKETS AROUND THREE (3)

VENT PENETRATIONS.

TARGETED REPAIRS:

A1.10

TYPE 1 & 2

ROOF PLANS

05.14.2025

SHEET NAME

REVISIONS

ISSUE

REV. DATE

PROJECT NAME

CLIENT

PROJECT NUMBER

SHEET NUMBER

15 82nd Drive, Suite 10 Gladstone, OR 97027

TEL: 503.772.1114

FAX: 503.772.4039

www.forensicbuilding.com info@forensicbuilding.com

COPYRIGHT ©2025 FORENSIC

BUILDING CONSULTANTS

All Rights Reserved

PRINT ALL DETAILS IN

COLOR AT 24x36

OR CCB# 155496

WA FORENW C94308

UT #8334529-5501

(RE) 25-062

Permit Issue Set

Bidding Issue Addenda - 06.26.2026

O re go n

D ep ar tm en t o f F or es try

A st or ia

D is tri ct

B ui ld in g

- R oo f a nd S id in g R eh ab ili ta tio n

(P O

-6

-0

8)

O re go n

De pa rtm en t o f F or es try

S ta te

S tre et , B ui ld in g

F, S al em

, O R

O

R -2

A st or ia , O

R

1 BUILDING 'D' ROOF PLAN

mhg

2 BUILDING 'E' ROOF PLAN

1/8" = 1'-0" ORIENTATION VARIES

mhg

3 BUILDING 'F' ROOF PLAN

1/8" = 1'-0" mhg

N

N N

A5.01

TYP.

UPPER

A5.01

SIM.

A5.01 SIM.

A5.01SIM.

A5.01 8

A5.01TYP.

A5.01

TYP.

LOWER

A5.--

ROOF PLAN KEYNOTES:

ROOF PLAN NOTES:

1. COORDINATE ROOF DEMOLITION WITH SCHEDULED WORK AT ADJACENT EXTERIOR WALL CLADDING

INTEGRATION WORK PER THE DESIGN DOCUMENTS AND ACCOMPANYING PROJECT MANUAL. PERFORM

SELECTIVE AND LIMITED DEMOLITION OF EXISTING WALL ASSEMBLIES AS REQUIRED.

2. VERIFY CLEARANCE REQUIREMENTS AND MATCH ASSEMBLY OF EXISTING FIRE RATED WALLS AND ROOF

SYSTEMS WHERE REPAIRED DURING THE COURSE OF REQUIRED WORK.

3. REPLACE EXTERIOR PLYWOOD AND GYPSUM WALLBOARD SHEATHING AS NECESSARY TO PERFORM REQUIRED WORK AND AS NECESSARY TO CHASE DAMAGE TO EXTINCTION. PATCH, REPAIR, AND MATCH

PLANE OF EXISTING ADJACENT SURFACES.

4. PLANS HAVE BEEN CREATED USING INFORMATION REPRODUCED FROM INFORMATION ACQUIRED FROM PUBLIC RECORD, THIRD PARTY DATA SETS, AND/OR PREPARED BY ORIGINAL/PREVIOUS ARCHITECT, DESIGNER, AND/OR CONSULTANT. PLANS ARE FOR REFERENCE TO EXISTING CONDITIONS, WALL LOCATIONS, AND FENESTRATIONS ONLY. BRING ANY DISCREPANCIES BETWEEN DESIGN DOCUMENTS AND ACTUAL PROJECT CONDITIONS TO THE IMMEDIATE ATTENTION OF THE BUILDING ENCLOSURE CONSULTANT AND

REQUEST A REVIEW.

5. CONTRACTOR TO VERIFY VENTILATION OF EXISTING BUILDING ATTIC AREA FOR VENTILATION REQUIREMENTS.

INSTALL ADDITIONAL INTAKE AT EAVE AND UPPER ROOF EXHAUST LOCATIONS AS REQUIRED.

6. CONTRACTOR SHALL MAKE REQUIRED REPAIRS TO EXISTING RATED DRAFT STOP ASSEMBLIES TO ENSURE

CONTINUOUS FIRE RATING FOR EACH EXISTING ATTIC AREA.

ROOF PLAN LEGEND:

REMOVE AND DISPOSE OF 100% OF EXISTING COMPOSITION ASPHALT SHINGLE

ROOFING, UNDERLAYMENT, STATIC VENTS, EXHAUST VENTS, AND ASSOCIATED ROOF

AND FLASHING COMPONENTS. INSTALL SCHEDULED COMPOSITION ASPHALT SHINGLE

ROOFING, UNDERLAYMENT, AND ASSOCIATED COMPONENTS PER DESIGN DOCUMENT

ROOF DETAILS AND PROJECT MANUAL.

INSTALL SCHEDULED ROOF GUTTERS AT ROOF EAVE LOCATIONS WITH DOWNSPOUTS

AND CLEANOUT LOCATED TO TIE INTO EXISTING SITE STORM SEWER LOCATIONS.

REFER TO DESIGN DOCUMENT PACKAGE AND PROJECT MANUAL.

STATIC STEMMED ROOF VENT ASSEMBLY, CONTRACTOR TO ACCOUNT FOR TIGHT-LINING

100% OF BUILDINGS BATH AND KITCHEN LOCATIONS AS OCCURS, REFER TO DETAIL 3/A5.02.

PLUMBING VENT STACK ASSEMBLY, REFER TO DETAIL 1/A5.03.

SCHEDULED CONTINUOUS RIDGE VENT, REFER TO DETAIL 8/A5.01.

APPROXIMATE LOCATION OF STEMMED STATIC ROOF VENT PENETRATION.

EXISTING ROOF SLOPE TO REMAIN.

APPROXIMATE LOCATION OF BOILER EXHAUST STACK PENETRATION.

APPROXIMATE LOCATION OF PLUMBING STACK VENT PENETRATION.

APPROXIMATE LOCATION OF TURBINE VENT PENETRATION.

2 TYP.

1 TYP.

2 TYP.1 TYP.

TARGETED ROOF REHABILITATION AND REPAIRS AT IDENTIFIED LOCATIONS TO BE DETAILED IN SIMILAR FASHION TO CONDITIONS FOR THE FULL ROOFING REPLACEMENT OCCURRING AT BUILDING 'A'. REFER

TO DESIGN PACKAGE FOR RELATED DETAILS AND CORRELATING CONDITIONS.

TARGETED ROOF REHABILITATION AND REPAIRS AT IDENTIFIED LOCATIONS TO BE DETAILED IN SIMILAR FASHION TO CONDITIONS FOR THE FULL ROOFING REPLACEMENT OCCURRING AT BUILDING 'A'. REFER

TO DESIGN PACKAGE FOR RELATED DETAILS AND CORRELATING CONDITIONS.

A5.03

TYP. AS

NEEDED

NOT USED

NOT USED

8 CCTV POST ATTACHMENT BRACKET CONDITION, REFER TO DETAIL 3/A3.06.

A5.03 SIM.

TYP.

A5.04

TYP. AS

NEEDED 2

A5.03

TYP. AS

NEEDED

APPROXIMATE LOCATION OF CONTINUOUS RIDGE EXHAUST VENT.

DS APPROXIMATE LOCATION OF EXISTING DOWNSPOUT, CLEANOUT, AND STORM

SEWER TIE-IN OR DAYLIGHT TO GRADE.

DS

DS

DS DS DS

DS

DS

DS

DS

DS DS

DS DS

DS

DS DS

DS

1 TYP.

ROOF ANCHOR FALL PROTECTION, REFER TO DETAIL 1/A5.01.

FP

FP FP

12'-0" O.C. TYP. ℄℄ EQ.9TYP.

4'- 0"

FPFPFPFPFPFPFPFPFP

PROPOSED FALL PROTECTION ROOF ANCHOR , REFER TO DETAIL 7/A5.04. LOCATE

12'-0" O.C. MAX. TYPICAL, EQ. DISTANCE FROM RIDGE ENDS, AND 4'-0" LATERAL

DISTANCE FROM ADJACENT RIDGE.

FP FP

12'-0" O.C. TYP.

EQ.

4'- 0"

FPFPFP

FP

4'-0"

FP

FP

FP

'-0

" O .C

. T

YP

EQ

FPFP

FP

FP

TYP.

TYP.

ESTIMATED ROOF WORK AT BUILDING 'E' SHALL INCLUDE:

· ASSUME REMOVAL AND REPLACEMENT OF 200 SQUARE FEET OF COMPOSITION ASPHALT

SHINGLE ROOFING AND UNDERLAYMENT, MATCHING EXISTING STYLE AND COLOR.

· ASSUME REMOVAL AND REPLACEMENT OF 128 SQUARE FEET OF EXISTING PLYWOOD

ROOF DECK SHEATHING. INSTALLED SHEATHING SHALL BE 5/8" CDX PLYWOOD.

· REPLACEMENT OF WEATHERPROOF FLASHING COLLARS/GASKETS AROUND THREE (3)

VENT PENETRATIONS.

· ASSUME 'LIKE FOR LIKE' REMOVAL AND REPLACEMENT OF 100 LINEAL FEET OF EXISTING

GUTTERS. TIE INTO EXISTING DOWNSPOUT LOCATIONS AS OCCURS.

TARGETED REPAIRS:

ESTIMATED ROOF WORK AT BUILDING 'F' SHALL INCLUDE:

· ASSUME REMOVAL AND REPLACEMENT OF 200 SQUARE FEET OF COMPOSITION ASPHALT

SHINGLE ROOFING AND UNDERLAYMENT, MATCHING EXISTING STYLE AND COLOR.

· ASSUME REMOVAL AND REPLACEMENT OF 128 SQUARE FEET OF EXISTING PLYWOOD

ROOF DECK SHEATHING. INSTALLED SHEATHING SHALL BE 5/8" CDX PLYWOOD.

· REPLACEMENT OF WEATHERPROOF FLASHING COLLARS/GASKETS AROUND THREE (3)

VENT PENETRATIONS.

A1.11

TYPE 3 & 4

ROOF PLANS

05.14.2025

SHEET NAME

REVISIONS

ISSUE

REV. DATE

PROJECT NAME

CLIENT

PROJECT NUMBER

SHEET NUMBER

15 82nd Drive, Suite 10 Gladstone, OR 97027

TEL: 503.772.1114

FAX: 503.772.4039

www.forensicbuilding.com info@forensicbuilding.com

COPYRIGHT ©2025 FORENSIC

BUILDING CONSULTANTS

All Rights Reserved

PRINT ALL DETAILS IN

COLOR AT 24x36

OR CCB# 155496

WA FORENW C94308

UT #8334529-5501

(RE) 25-062

Permit Issue Set

Bidding Issue Addenda - 06.26.2026

O re go n

D ep ar tm en t o f F or es try

A st or ia

D is tri ct

B ui ld in g

- R oo f a nd S id in g R eh ab ili ta tio n

(P O

-6

-0

8)

O re go n

De pa rtm en t o f F or es try

S ta te

S tre et , B ui ld in g

F, S al em

, O R

O

R -2

A st or ia , O

R

1 BUILDING 'G' ROOF PLAN

mhg

1 BUILDING 'H' ROOF PLAN

1/8" = 1'-0" mhg

N N

A5.01

TYP.

A501TYP.

-4

A5.01 TYP.

A5.01TYP

ROOF PLAN KEYNOTES:

ROOF PLAN NOTES:

1. COORDINATE ROOF DEMOLITION WITH SCHEDULED WORK AT ADJACENT EXTERIOR WALL CLADDING

INTEGRATION WORK PER THE DESIGN DOCUMENTS AND ACCOMPANYING PROJECT MANUAL. PERFORM

SELECTIVE AND LIMITED DEMOLITION OF EXISTING WALL ASSEMBLIES AS REQUIRED.

2. VERIFY CLEARANCE REQUIREMENTS AND MATCH ASSEMBLY OF EXISTING FIRE RATED WALLS AND ROOF

SYSTEMS WHERE REPAIRED DURING THE COURSE OF REQUIRED WORK.

3. REPLACE EXTERIOR PLYWOOD AND GYPSUM WALLBOARD SHEATHING AS NECESSARY TO PERFORM REQUIRED WORK AND AS NECESSARY TO CHASE DAMAGE TO EXTINCTION. PATCH, REPAIR, AND MATCH

PLANE OF EXISTING ADJACENT SURFACES.

4. PLANS HAVE BEEN CREATED USING INFORMATION REPRODUCED FROM INFORMATION ACQUIRED FROM PUBLIC RECORD, THIRD PARTY DATA SETS, AND/OR PREPARED BY ORIGINAL/PREVIOUS ARCHITECT, DESIGNER, AND/OR CONSULTANT. PLANS ARE FOR REFERENCE TO EXISTING CONDITIONS, WALL LOCATIONS, AND FENESTRATIONS ONLY. BRING ANY DISCREPANCIES BETWEEN DESIGN DOCUMENTS AND ACTUAL PROJECT CONDITIONS TO THE IMMEDIATE ATTENTION OF THE BUILDING ENCLOSURE CONSULTANT AND

REQUEST A REVIEW.

5. CONTRACTOR TO VERIFY VENTILATION OF EXISTING BUILDING ATTIC AREA FOR VENTILATION REQUIREMENTS.

INSTALL ADDITIONAL INTAKE AT EAVE AND UPPER ROOF EXHAUST LOCATIONS AS REQUIRED.

6. CONTRACTOR SHALL MAKE REQUIRED REPAIRS TO EXISTING RATED DRAFT STOP ASSEMBLIES TO ENSURE

CONTINUOUS FIRE RATING FOR EACH EXISTING ATTIC AREA.

ROOF PLAN LEGEND:

APPROXIMATE LOCATION OF STEMMED STATIC ROOF VENT PENETRATION.

EXISTING ROOF SLOPE TO REMAIN.

APPROXIMATE LOCATION OF BOILER EXHAUST STACK PENETRATION.

APPROXIMATE LOCATION OF PLUMBING STACK VENT PENETRATION.

APPROXIMATE LOCATION OF TURBINE VENT PENETRATION.

2 TYP.

1 TYP.

2TYP.

1TYP.

A5.02

A5.01

TARGETED ROOF REHABILITATION AND REPAIRS AT IDENTIFIED LOCATIONS TO BE DETAILED IN SIMILAR FASHION TO CONDITIONS FOR THE FULL ROOFING REPLACEMENT OCCURRING AT BUILDING 'A'. REFER

TO DESIGN PACKAGE FOR RELATED DETAILS AND CORRELATING CONDITIONS.

4'- 0"

A5.02

SIM. AS

NEEDED

NOT USED

APPROXIMATE LOCATION OF CONTINUOUS RIDGE EXHAUST VENT.

DS APPROXIMATE LOCATION OF EXISTING DOWNSPOUT, CLEANOUT, AND STORM

SEWER TIE-IN OR DAYLIGHT TO GRADE.

DS

DS

DS

DS

DS

DS DS

DS

REMOVE AND DISPOSE OF 100% OF EXISTING COMPOSITION ASPHALT SHINGLE

ROOFING, UNDERLAYMENT, STATIC VENTS, EXHAUST VENTS, AND ASSOCIATED ROOF

AND FLASHING COMPONENTS. INSTALL SCHEDULED COMPOSITION ASPHALT SHINGLE

ROOFING, UNDERLAYMENT, AND ASSOCIATED COMPONENTS PER DESIGN DOCUMENT

ROOF DETAILS AND PROJECT MANUAL.

INSTALL SCHEDULED ROOF GUTTERS AT ROOF EAVE LOCATIONS WITH DOWNSPOUTS

AND CLEANOUT LOCATED TO TIE INTO EXISTING SITE STORM SEWER LOCATIONS.

REFER TO DESIGN DOCUMENT PACKAGE AND PROJECT MANUAL.

STATIC STEMMED ROOF VENT ASSEMBLY, CONTRACTOR TO ACCOUNT FOR TIGHT-LINING

100% OF BUILDINGS BATH AND KITCHEN LOCATIONS AS OCCURS, REFER TO DETAIL 3/A5.02.

PLUMBING VENT STACK ASSEMBLY, REFER TO DETAIL 1/A5.03.

SCHEDULED CONTINUOUS RIDGE VENT, REFER TO DETAIL 8/A5.01.

ROOF ANCHOR FALL PROTECTION, REFER TO DETAIL 1/A5.01.

FP

ANTENNA POLE ASSEMBLY AND 3-POINT GUY-WIRE ATTACHMENT, REFER TO VENT PIPE

PENETRATION DETAIL 1/A5.03 FOR SIMILAR (POST BASE) INTEGRATION AND TO DETAIL

7/A5.04 (GUY ANCHOR).

8 NOT USED

9 PROPOSED FALL PROTECTION ROOF ANCHOR , REFER TO DETAIL 7/A5.04. LOCATE

12'-0" O.C. MAX. TYPICAL, EQ. DISTANCE FROM RIDGE ENDS, AND 4'-0" LATERAL

DISTANCE FROM ADJACENT RIDGE.

FP

FP

'-0

" O .C

. T

YP

EQ

TYP.

4'-0"

FP

FP

FP

FP

FP

FP

FP

'-0

" O .C

. T

YP

EQ

4'-0"

TYP.

ESTIMATED ROOF WORK AT BUILDING 'G' SHALL INCLUDE:

· ASSUME REMOVAL AND REPLACEMENT OF 200 SQUARE FEET OF COMPOSITION ASPHALT

SHINGLE ROOFING AND UNDERLAYMENT, MATCHING EXISTING STYLE AND COLOR.

· ASSUME REMOVAL AND REPLACEMENT OF 128 SQUARE FEET OF EXISTING PLYWOOD

ROOF DECK SHEATHING. INSTALLED SHEATHING SHALL BE 5/8" CDX PLYWOOD.

· REPLACEMENT OF WEATHERPROOF FLASHING COLLARS/GASKETS AROUND THREE (3)

VENT PENETRATIONS.

TARGETED REPAIRS:

A1.12

TYPE 5

ROOF PLAN

05.14.2025

SHEET NAME

REVISIONS

ISSUE

REV. DATE

PROJECT NAME

CLIENT

PROJECT NUMBER

SHEET NUMBER

15 82nd Drive, Suite 10 Gladstone, OR 97027

TEL: 503.772.1114

FAX: 503.772.4039

www.forensicbuilding.com info@forensicbuilding.com

COPYRIGHT ©2025 FORENSIC

BUILDING CONSULTANTS

All Rights Reserved

PRINT ALL DETAILS IN

COLOR AT 24x36

OR CCB# 155496

WA FORENW C94308

UT #8334529-5501

(RE) 25-062

Permit Issue Set

Bidding Issue Addenda - 06.26.2026

O re go n

D ep ar tm en t o f F or es try

A st or ia

D is tri ct

B ui ld in g

- R oo f a nd S id in g R eh ab ili ta tio n

(P O

-6

-0

8)

O re go n

De pa rtm en t o f F or es try

S ta te

S tre et , B ui ld in g

F, S al em

, O R

O

R -2

A st or ia , O

R

3"

'-0

S

C A

LE

F

A C

TO

R

: 4

FILLET BEAD OF SEALANT,

TYPICAL

SCHEDULED SAM, EXTEND FULL HEIGHT

OF VERTICAL TRIM MEMBER, EXTEND

BEYOND TRIM EDGE AS INDICATED

SCHEDULED FIBER CEMENT

PLANK LAP CLADDING

SCHEDULED TRIM - SIZE

PER SPECIFICATIONS -

PRIME PRIOR TO SEALANT

INSTALLATION (TYP.)

1/2" - 1"

CLEAR

DOWNSPOUT (AS OCCURS)

EXISTING SHEATHING

SCHEDULED CODE COMPLIANT DRAINAGE WRB

4 SAME PLANE TRIM WITH BRACKETED

3" = 1'-0" DOWNSPOUT AT FIBER CEMENT CLADDING AND TRIM - PLAN VIEW

mhg

2" TYP.

EA. SIDE

1"

MIN.

1 1/4"

MIN.

4"

1 GRADE BASE OF WALL FLASHING

3" = 1'-0" WITH CLEARANCE AT FIBER CEMENT CLADDING OVER RAINSCREEN CAVITY

mhg

2"

MIN.

EXISTING SHEATHING

SCHEDULED WRB, LAP OVER SAM AND

BASE OF WALL FLASHING BELOW

SCHEDULED FIBER CEMENT PLANK

LAP CLADDING

1/2"

24-GAUGE 316 STAINLESS STEEL

FLASHING WITH BACK HEM

(REFER TO SHEET NOTES)

2"

MIN.

6"

2"

MIN.

CONTINUOUS 3/8" DIA. BEAD OF

SCHEDULED SEALANT

SCHEDULED SAM STARTER STRIP,

REFER TO SHEET NOTES

SCHEDULED PRESSURE TREATED

FURRING STRIPS WITH INSECT SCREENS

AT HORIZONTAL TERMINATIONS

EXISTING GRADE

6"

MIN.

3 BASE OF WALL FLASHING WITH KERF CUT

3" = 1'-0" CONCRETE SLAB AND FIBER CEMENT CLADDING OVER RAINSCREEN CAVITY

mhg

1"

1 1/2"

MIN.

1 1/2"

2"

MIN.

4"

2"

MIN.

1" CLR.

24-GAUGE 316 STAINLESS STEEL

FLASHING SET INTO KERF CUT -

FILL WITH SEALANT PRIOR TO

INSTALLING FLASHING

SAM (REFER TO SHEET NOTES)

CONTINUOUS 3/8" DIA BEAD OF

SEALANT

SCHEDULED SHEATHING

SCHEDULED WRB, LAP OVER SAM

AND BASE OF WALL FLASHING

BELOW AND SEAL

SCHEDULED PRESSURE TREATED

FURRING STRIPS WITH INSECT

SCREENS AT TERMINATIONS

SCHEDULED FIBER CEMENT PLANK

LAP CLADDING

AT GRADE STORM DRAIN

CONNECTION TO

DOWNSPOUT, MODIFY AS

REQUIRED TO ACCOMMODATE

DOWNSPOUT DIAMETER

18" MIN.OR

MATCH EXISTING

METAL DOWNSPOUT FROM

GUTTER ABOVE, MAINTAIN 1/2" - 1"

STANDOFF FROM FIBER CEMENT

CLADDING

SCHEDULED FIBER CEMENT

PLANK LAP CLADDING

6"

MIN.

EXISTING GRADE (SEE

NOTES FOR CONC. WALK)

SCHEDULED PRESSURE

TREATED FURRING STRIPS

WITH INSECT SCREENS AT

TERMINATIONS

2 DOWNSPOUT CLEANOUT ASSEMBLY

3" = 1'-0" AT GRADE CLEARANCE WITH FIBER CEMENT PLANK LAP CLADDING

mhg A3.00 Wall Detals - OFD Astoria District.dwg

PRE-MANUFACTURED AND

PRE-FINISHED METAL

DOWNSPOUT CLEAN-OUT

WITH SS CATCH SCREEN,

INSTALL PER

MANUFACTURER'S

REQUIREMENTS

METAL SCREEN COVER,

POP-RIVET AT FLANGE

AND INSURE A MIN. 15°

ANGLE AND MIN. 3"

VERTICAL OPENING

ABOVE SCREEN FOR

DEBRIS EVACUATION.

TRIM AND CAP SADDLE FLASHING - ISOMETRIC INSET

5 VERTICAL TRANSITION JOINT

3" = 1'-0" AT FIBER CEMENT CLADDING TO EXPOSED CONCRETE - PLAN VIEW

mhg

SAM - LAP OVER WRB ONTO UNDERLYING

SHEATHING AND ADJACENT CONCRETE

FILLET BEAD OF SEALANT (TYP.)

2"

MIN.

2"

MIN.

24-GAUGE 316 STAINLESS

STEEL FLASHING TO CLOSE

END OF CAVITY ON TOP OF

FURRING

2"

MIN.

1/2" DYNAMIC

SEALANT JOINT

(TYP.)

6" MIN.

SIZE TO SUIT

FIELD CONDITIONS

1" CONFIRM DURING MOCK-UP

SEAL EDGE OF SAM

WITH COMPATIBLE

SEALANT

SCHEDULED 5/4 PVC TRIM

SCHEDULED SHEATHING

SCHEDULED WRB

PRESSURE TREATED FURRING STRIPS, TYP.

SCHEDULED FIBER CEMENT PLANK LAP CLADDING

REFER TO

NOTE 8

LINE OF TRIM CAP FLASHING ABOVE

5"

4"

4"

EXTEND 1/2"

BELOW TOP

OF TRIM

4"

24-GAUGE PRE-FINISHED METAL

TRIM CAP SADDLE FLASHING,

INTEGRATE AND LAP WITH WRB

AND BASE OF WALL FLASHING.

(EXTEND OVER TRIM 1" MIN.)

6 INSIDE CORNER TRANSITION JOINT

3" = 1'-0" AT FIBER CEMENT CLADDING TO EXPOSED CONCRETE - PLAN VIEW

mhg

SCHEDULED SAM TO LAP OVER WRB

STATIC FILLET JOINT OF SCHEDULED SEALANT, TYP.

2"

MIN.

1/2" DYNAMIC SEALANT JOINT (TYP.)

24-GAUGE 316 STAINLESS STEEL

FLASHING WITH HEMMED RETURN

SCHEDULED 2x CEDAR TRIM - PRIME

PRIOR TO INSTALLATION, (TYP.)

SCHEDULED WRB

EXISTING SHEATHING

LAP SAM 2" MIN.

ONTO CONCRETE

REFER TO

NOTE 8

SEAL EDGE OF SAM

WITH COMPATIBLE

SEALANT SCHEDULED FURRING STRIPS, TYP.

SCHEDULED FIBER CEMENT PLANK LAP CLADDING

4"

SIZE

TO SUIT

CONDITION 1/2"

SCHEDULED BUTYL-BASED SAM

FLASHING - FULLY WRAP END OF FIN

WALL AND ENSURE CONTINUOUS

COVERAGE FULL WALL HEIGHT

SCHEDULED TRIM, PRIME

ALL FACES PRIOR TO

INSTALLATION, (TYP.)

REMOVE AND REPLACE 100% OF

EXISTING (2) LAYERS OF 5/8"

TYPE 'X' GYPSUM WALLBOARD

SHEATHING, TYPICAL EACH SIDE

OF RATED WALL ASSEMBLY

SCHEDULED WRB, LAP OVER

METAL BASE-OF- WALL

FLASHING BELOW AND SEAL

SCHEDULED FIBER CEMENT

PLANK LAP CLADDING

SCHEDULED WRB

STATIC FILLET JOINT OF

SCHEDULED SEALANT, TYP.

SCHEDULED FIBER CEMENT

PLANK LAP CLADDING

SCHEDULED 2X CEDAR TRIM -

PRIME ALL SIDES PRIOR TO

SEALANT INSTALLATION, (TYP.)

4 1/2"

4 1/2"

SCHEDULED PRESSURE TREATED

FURRING STRIPS WITH INSECT

SCREENS AT TERMINATIONS

EXISTING SHEATHING

STATIC FILLET JOINT OF

SCHEDULED SEALANT, TYP.

4 1/2"

MIN.

NOTE: ENSURE BASE OF WALL FLASHING AT BASE

OF WALL IS CONTINUOUS AROUND END OF WALL

INCLUDING DOWN LEG AT SLAB AS OCCURS

7 PERPENDICULAR RATED PARTITION WALL TRANSITION

3" = 1'-0" WITH FIBER CEMENT CLADDING

mhg

8 RATED PARTITION WALL END CAP DETAIL

3" = 1'-0" WITH FIBER CEMENT CLADDING, TRIM, AND SEALANT

mhg

EXISTING 2x RATED SEPARATION

WALL, EVALUATE FRAMING DURING

DEMOLITION FOR REQUIRED

REPAIRS - REMOVE AND REPLACE

DAMAGED FRAMING, (CHASE

DAMAGE TO EXTINCTION) MATCH

EXISTING SIZE AND SPACING

SCHEDULED MIN. 9" SAM

CENTERED CORNER, TYP.

NOTES:

1. CONTRACTOR TO VERIFY COMPONENT CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES.

2. CAREFULLY REMOVE EXISTING CLADDING, TRIM, WRB, AND ASSOCIATED FLASHINGS ALONG ELEVATION AREAS TO BE

REHABILITATED.

3. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH UPTURNED ENDS AT TERMINATIONS AND CONTINUOUS AROUND

CORNERS. SLOPE HORIZONTAL LEGS TO DRAIN, REFER TO DETAIL 1/A3.01

4. APPLY PRIMER TO CONCRETE SLAB AND FOUNDATION WALL SUBSTRATES PRIOR TO SAM APPLICATION SAM.

5. SHEET METAL FLASHING IS TO FULLY COVER SAM AND ICE AND WATER SHIELD MATERIALS ENTIRELY FROM UV EXPOSURE.

6. INSTALL LOW EXPANDING FOAM AROUND ALL PENETRATIONS TO LIMIT AIR LEAKAGE.

7. IF PENETRATION DOES NOT FALL ALONG FRAMING, INSTALL STRAPPING OR BLOCKING AND INTERMEDIATE FURRING STRIPS

AS NEEDED FOR BLOCK AND SIDING TERMINATIONS.

8. PROVIDE EXTENSIONS WHERE NEEDED TO PIPES, DUCTS, AND OTHER PENETRATIONS TO ACCOMMODATE INCREASED

THICKNESS OF WALL ASSEMBLIES.

9. PRIME AND PREP CLADDING AND TRIM AS REQUIRED TO RECEIVE SEALANT AND PAINT.

10. ISOMETRIC DETAILS ARE INTENDED TO ILLUSTRATE THE RECOMMENDED SEQUENCE OF COMPONENT INSTALLATION AND

GENERAL SHAPE AND PROFILE CONCEPTS OF FLASHING, WATERPROOFING, AND TRANSITION ASSEMBLIES. CERTAIN

ADJACENT COMPONENTS HAVE NOT BEEN ILLUSTRATED FOR DETAIL CLARITY.

11. TREAT ALL CUT EDGES AT PRESSURE-TREATED LUMBER, INCLUDING KERF CUTS, WITH COMPATIBLE TREATMENT SOLUTION

PER AMERICAN WOOD PROTECTION ASSOCIATION - AWPA - M4.

12. REFER TO PROJECT MANUAL, PRODUCT SPECIFICATIONS FOR SCHEDULED COMPONENT ASSEMBLIES.

EXISTING 2x RATED SEPARATION

WALL, EVALUATE FRAMING DURING

DEMOLITION FOR REQUIRED

REPAIRS - REMOVE AND REPLACE

DAMAGED FRAMING, (CHASE

DAMAGE TO EXTINCTION) MATCH

EXISTING SIZE AND SPACING

NOTE: REFER TO DETAIL 8/A5.05 FOR TOP

OF RATED PARTITION WALL CONDITION

REMOVE AND REPLACE 100%

OF EXISTING (2) LAYERS OF

5/8" TYPE 'X' GYPSUM

WALLBOARD SHEATHING,

TYPICAL EACH SIDE OF

RATED WALL ASSEMBLY

1/

2"

'-0

S

C A

LE

F

A C

TO

R

: 8 1"

'-0

S C

A

LE

F A

C

TO

R : 1

A3.02

WALL DETAILS

05.14.2025

SHEET NAME

REVISIONS

ISSUE

REV. DATE

PROJECT NAME

CLIENT

PROJECT NUMBER

SHEET NUMBER

15 82nd Drive, Suite 10 Gladstone, OR 97027

TEL: 503.772.1114

FAX: 503.772.4039

www.forensicbuilding.com info@forensicbuilding.com

COPYRIGHT ©2025 FORENSIC

BUILDING CONSULTANTS

All Rights Reserved

PRINT ALL DETAILS IN

COLOR AT 24x36

OR CCB# 155496

WA FORENW C94308

UT #8334529-5501

(RE) 25-062

Permit Issue Set

Bidding Issue Addenda - 06.26.2026

O re go n

D ep ar tm en t o f F or es try

A st or ia

D is tri ct

B ui ld in g

- R oo f a nd S id in g R eh ab ili ta tio n

(P O

-6

-0

8)

O re go n

De pa rtm en t o f F or es try

S ta te

S tre et , B ui ld in g

F, S al em

, O R

O

R -2

A st or ia , O

R

'-0

S

C A

LE

F

A C

TO

R

: 4 6 TOP-OF-WALL TO GABLE/RAKE FASCIA

3" = 1'-0" WITH FIBER CEMENT PLANK LAP CLADDING

mhg

SEALANT

4" SAM

SCHEDULED PRESSURE TREATED

FURRING STRIPS WITH INSECT

SCREENS AT TERMINATIONS

SCHEDULED WRB

SCHEDULED FIBER CEMENT

PLANK LAP CLADDING

EXISTING SHEATHING

SCHEDULED 5/4 FIBER CEMENT

TRIM - PRIME PRIOR TO SEALANT

INSTALLATION, (TYP.)

FILLET BEAD OF

SEALANT, TYPICAL

2"

MIN.

2"

MIN.

2"

MIN.

2"

MIN.

MIN. 1/4" CLEAR

DO NOT SEAL

SCHEDULED TRIM - PRIME ALL

CUTS PRIOR TO INSTALLATION,

(TYP.)

4" SCHEDULED SAM

COMPATIBLE SEALANT

SCHEDULED PRESSURE TREATED

FURRING STRIPS WITH INSECT

SCREENS AT TERMINATIONS

SCHEDULED WRB

SCHEDULED FIBER CEMENT

PLANK LAP CLADDING

EXISTING SHEATHING

REFER TO ROOF DETAIL 2/A5.01 FOR

REPLACEMENT ROOF ASSEMBLY

COMPONENT ASSEMBLY

EXISTING ROOF EAVE BLOCKING

WITH VENT (AS OCCURS)

EXISTING JOIST FRAMING (BEYOND)

EXISTING ROOF SHEATHING

REFER TO ROOF DETAIL 3/A5.01 FOR

REPLACEMENT ROOF ASSEMBLY

COMPONENT ASSEMBLY

5 TOP-OF-WALL AT EAVE OVERHANG

3" = 1'-0" WITH FIBER CEMENT PLANK LAP CLADDING

mhg

1 RATED PARAPET PARTITION WALL AT ROOF

3" = 1'-0" WITH CAP FLASHING AND FIBER CEMENT PLANK LAP CLADDING

mhg

CONTINUOUS FILLET BEAD OF

SCHEDULED SEALANT - TYP

SCHEDULED FIBER CEMENT

PLANK LAP CLADDING

5/4 x 4 FIBER CEMENT TRIM - PRIME

ALL CUT AND NON-PRIMED FACES

PRIOR TO INSTALLATION, (TYP.) - TRIM

TO BE CONTINUOUS OVER END CAP

WALL TRIM, REFER TO DETAIL 8/A3.02

SCHEDULED WRB, LAP OVER ROOF TO

WALL STEP FLASHING, SAM AND ROOF

UNDERLAYMENT BELOW AND SEAL

REMOVE AND REPLACE 100% OF EXISTING

(2) LAYERS OF 5/8" TYPE 'X' GYPSUM

WALLBOARD SHEATHING, TYPICAL EACH

SIDE OF RATED WALL ASSEMBLY

2"

2"

EXISTING 2x SEPARATION PARAPET

WALL, REPAIR DAMAGED FRAMING

AS REQUIRED, MATCH EXISTING SIZE

AND SPACING

4"

MIN.

SCHEDULED HIGH TEMP SAM - LAP

ONTO ADJACENT SAM 6" MIN. AND OVER

TOP OF WALL ONTO WRB BELOW - DO

NOT PENETRATE WITH FASTENERS

STAINLESS STEEL FASTENERS

WITH NEOPRENE WASHER, TYP.

1"

MIN.

24-GAUGE 316 STAINLESS STEEL OR

ALUMINUM EQUIVALENT PARAPET CAP

FLASHING WITH HEMMED KICK TYPICAL

EACH SIDE

SCHEDULED PRESSURE TREATED

FURRING STRIPS WITH INSECT

SCREENS AT TERMINATIONS, TYP.

CONTINUOUS P.T. NAILER

2 BUILDING A GABLE END ANTENNA / METEOROLOGICAL

3" = 1'-0" EQUIPMENT MOUNT WITH ATTACHMENT AT FASCIA TRIM

mhg

EXISTING ROOF SHEATHING

AND FRAMING

REFER TO ROOF DETAIL

3/A5.01 FOR REPLACEMENT

ROOF ASSEMBLY

COMPONENT ASSEMBLY

6"x6"x1/4"T A36 STEEL WELDED

RIDGE PLATE (MATCH ROOF

PITCH AND CENTER ON RIDGE)

WITH WELDED 1/2" DIA. X 3 1/8"

THREADED ATTACHMENT ROD -

PRE-DRILL PENETRATION AND

FULLY BED IN ROOF MASTIC

NOTES:

1. CONTRACTOR TO VERIFY COMPONENT CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES.

2. CAREFULLY REMOVE EXISTING CLADDING, TRIM, WRB, AND ASSOCIATED FLASHINGS ALONG ELEVATION AREAS TO

BE REHABILITATED.

3. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH UPTURNED ENDS AT TERMINATIONS AND CONTINUOUS

AROUND CORNERS. SLOPE HORIZONTAL LEGS TO DRAIN, REFER TO DETAIL 1/A3.01

4. APPLY PRIMER TO CONCRETE SLAB AND FOUNDATION WALL SUBSTRATES PRIOR TO SAM APPLICATION SAM.

5. SHEET METAL FLASHING IS TO FULLY COVER SAM AND ICE AND WATER SHIELD MATERIALS ENTIRELY FROM UV

EXPOSURE.

6. INSTALL LOW EXPANDING FOAM AROUND ALL PENETRATIONS TO LIMIT AIR LEAKAGE.

7. IF PENETRATION DOES NOT FALL ALONG FRAMING, INSTALL STRAPPING OR BLOCKING AND INTERMEDIATE

FURRING STRIPS AS NEEDED FOR BLOCK AND SIDING TERMINATIONS.

8. PROVIDE EXTENSIONS WHERE NEEDED TO PIPES, DUCTS, AND OTHER PENETRATIONS TO ACCOMMODATE

INCREASED THICKNESS OF WALL ASSEMBLIES.

9. PRIME AND PREP CLADDING AND TRIM AS REQUIRED TO RECEIVE SEALANT AND PAINT.

10. ISOMETRIC DETAILS ARE INTENDED TO ILLUSTRATE THE RECOMMENDED SEQUENCE OF COMPONENT

INSTALLATION AND GENERAL SHAPE AND PROFILE CONCEPTS OF FLASHING, WATERPROOFING, AND TRANSITION ASSEMBLIES. CERTAIN ADJACENT COMPONENTS HAVE NOT BEEN ILLUSTRATED FOR DETAIL CLARITY.

11. TREAT ALL CUT EDGES AT PRESSURE-TREATED LUMBER, INCLUDING KERF CUTS, WITH COMPATIBLE TREATMENT

SOLUTION PER AMERICAN WOOD PROTECTION ASSOCIATION - AWPA - M4.

12. REFER TO PROJECT MANUAL, PRODUCT SPECIFICATIONS FOR SCHEDULED COMPONENT ASSEMBLIES.

EXISTING ROOF SHEATHING

AND FRAMING

3 BUILDING D CCTV POST ATTACHMENT BRACKET

3" = 1'-0" CONDITION AT EXISTING T1-11 CLADDING

mhg

EXISTING T1-11 PANEL CLADDING, CLEAN AND

PREP AS NECESSARY TO INSTALL BRACKET

AND FLASHED MOUNTING BLOCK (EXISTING

PLANK LAP ON BUILDING 'H' NOT IN SCOPE)

EXISTING WRB (AS OCCURS) TO REMAIN

EXISTING ROOF SHEATHING

AND FRAMING

REPLACEMENT ROOF

ASSEMBLY, REFER TO

DETAIL 4/A5.01 FOR

SCHEDULED COMPONENTS

STATIC FILLET SEALANT JOINT

(TYP. EACH SIDE AND BOTTOM

24-GAUGE 316 STAINLESS STEEL HEAD

FLASHING WITH GUM-LIP SEALANT KICK

SET ON BEAD OF SEALANT - EXTEND 1"

MIN. BEYOND MOUNTING BLOCK

5/4" x 12" x 6" FIBER CEMENT MOUNTING

BLOCK, EXTEND 1" BEYOND EA. BRACKET

SIDE , PRIME ALL FACES PRIOR TO INSTALL

INSTALL MIN. 2x10

BLOCKING AT POST

BRACKET WALL

ATTACHMENT

LOCATIONS, TYP.

CONTINUOUS BUTYL-

BASED SAM BEHIND

MOUNTING BLOCK, TRIM

FLUSH AND FINISH EDGE

WITH COMPATIBLE

SEALANT

4"Wx10"Hx1/4"T A36 STEEL POST

ATTACHMENT BRACKET, PRIME

WITH ZINC-RICH PRIMER AND PAINT

(COLOR AS SELECTED BY OWNER)

3"

1 1/2"

7"

1 1/2"

2"

1/2" 1/2"

1/2"

REFER TO DETAIL 6/A5.02 FOR

SIMILAR WEATHER PROOFING

TREATMENT OF PENETRATION -

MODIFY FLASHING AND

INSTALLED COMPONENTS AS

REQUIRED FOR CONDITION

NOTE: COMPLETED ASSEMBLY TO BE

APPROVED AT TIME OF MOCK-UP

3/8" EPDM SPACER BETWEEN POST

BASE AND BRACKET ANGLE

STAINLESS STEEL U-BOLT AND CLAMP

MOUNT BRACKET - LOCATE AND ATTACH

AT TOP AND BOTTOM FASTENER

POSITIONS, SIZE PER POST DIA.

4"

10"

EXISTING CCTV POST TO BE

REMOVED AND REINSTALLED OR

DISPOSED OF AND REPLACED

PRE-DRILL HOLES

TO ALIGN WITH

U-BOLD FASTENERS

NOTE: DETAIL CONDITION SIMILARLY

AT BUILDINGS G AND H GABLE FASCIA

REFER TO ELEVATION

PHOTOS FOR GABLE

WALL LOUVER VENT

LOCATIONS

1" MIN. THICK SYMAR MASTICATED

FIBER-REINFORCED RUBBER

BEARING PADS - TAPERED SHAPE TO

MATCH ROOF SLOPE AND LOCATE

EA. SIDE OF RIDGE PEAK - CUT TO

SIZE AND PRE DRILL FOR THREADED

FASTENER PASS- THROUGH

FABRICATED 4"Wx24"Hx3/8"T A36

STEEL POST ATTACHMENT ANGLE,

PRIME WITH ZINC-RICH PRIMER

AND PAINT (COLOR AS SELECTED

BY OWNER)

3/8" EPDM SPACER BETWEEN POST

BASE AND BRACKET ANGLE

STAINLESS STEEL U-BOLT AND CLAMP

MOUNT BRACKET - LOCATE AND ATTACH

AT TOP AND BOTTOM FASTENER

POSITIONS, SIZE PER POST DIA.

EXISTING ANTENNA /…