2025.06.26 -Permit Issue Set Addendum 2 - ODF Astoria District.pdf
PDF 2 MB Posted
- Attached to
- Roofing and siding Rehabilitation
- Solicitation number
- S-62900-00011088
- Issued by
- Clatsop County, Oregon
About this file
This document is a permit issue set for the Oregon Department of Forestry's Astoria District Building Roof and Siding Rehabilitation Project, located at 92219 Highway 202 in Astoria, Oregon. The project involves comprehensive rehabilitation of seven existing facility buildings, with primary focus on the main office building. The scope includes complete removal and replacement of exterior components such as siding, windows, doors, and roofing across multiple structures. Specific work includes removing and disposing of existing hardboard and fiber cement wall cladding, vinyl window assemblies, asphalt shingle roofing, and installing new weather-resistant barriers, flashings, fiber cement cladding, windows, and roofing materials.
The project is structured as a single-phase rehabilitation effort to be performed while buildings remain occupied, with work potentially not occurring in numerical order relative to site layout. The estimated work includes targeted repairs and full replacements across different buildings, with varying extents of intervention. Estimated quantities include removal and replacement of approximately 200 square feet of roofing and 128 square feet of plywood roof deck sheathing for several buildings. The project is designed under 2022 Oregon Structural Specialty Code and other relevant state building and safety codes, with a permit issue date of May 14, 2025, and a bidding issue addendum date of June 26, 2026. The contract is being managed by Forensic Building Consultants, with the Oregon Department of Forestry as the primary client.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VICINITY MAP
N
PROJECT INFORMATION:
ADDRESS:
Oregon Department of Forestry Astoria District 92219 Highway 202, Astoria, OR 97103 PO Box 950 Astoria, OR 97103
LEGAL DESCRIPTION:
Township 8N, Range 9W, Section 27, Tax Lot 2000, Clatsop County,
32.70 Acres
PERMIT No.:
TBD
PROJECT SUMMARY:
This Design Contract Document package is for Permit Issue purposes and are for project construction. Refer to sheets A0.00, A1.00 Architectural Site Plan, and to the Project Manual Summary of Work section for full project scope, basis of design, and description.
PROJECT DESIGN / ASSEMBLY GROUPS:
A0.00 COVER SHEET, GENERAL NOTES, ABBREVIATIONS &
SYMBOLS, CODE REVIEW, AND PROJECT DESCRIPTION
A0.10 SHEET SEQUENCE AND DETAIL INDEX
A1.00 SITE PLAN AND ROOF PLAN SHEETS
A2.00 REFERENCE BUILDING ELEVATIONS PHOTOS
A3.00 WALL DETAILS
A4.00 WALL OPENING DETAILS
A5.00 ROOF DETAILS
Building H: Chemical Storage Warehouse - North Elevation View Aerial View - Looking North
05.14.2025 - PERMIT ISSUE SET
Oregon Department of Forestry - Astoria District Building
Roof and Siding Rehabilitation Project Drawings (PO-62900-00046358)
PROJECT
LOCATION
EXISTING USE AND OCCUPANCY:
1. Zoning: LR (Land Reserve)
2. Zoning Overlay: n/a
3. Occupancy Groups: B, S, U
4. Construction Type: Type VB
5. County Seat: Clatsop (Unincorporated)
6. Tax Account: 60164 & 27465 (Included for Coordination)
7. Tax Map: 80927 0002000 (Included for Coordination)
SITE AREAS AND BUILDING HEIGHTS:
1. Site Area: 32.68 AC. (Unchanged)
2. Number of Buildings: 7 (Unchanged)
3. Total Site Building Area: 16,925 SF (Existing) (Unchanged)
4. Number of Stories: Varies (Existing) (Unchanged)
5. Existing Building Heights: (Existing) (Unchanged)
APPLICABLE PROJECT CODES:
1. BUILDING CODES IN EFFECT AT TIME OF REHABILITATION PROJECT:
· STATE OF OREGON 2022 OREGON STRUCTURAL SPECIALTY CODE
(O.S.S.C.) AMENDMENTS (BASED ON 2021 IBC)
· 2021 OREGON ENERGY EFFICIENCY SPECIALTY CODE (OEESC)
· 2022 OREGON MECHANICAL SPECIALTY CODE (BASED ON THE 2021 IMC
& INTERNATIONAL FUEL GAS CODE (IFGC)
· 2021 PORTLAND FIRE CODE AND THE 2019 OREGON FIRE CODE
· 2021 OREGON ELECTRICAL SPECIALTY CODE (BASED ON THE 2020 NFPA
70 - NATIONAL ELECTRICAL CODE)
· 2021 OREGON PLUMBING SPECIALTY CODE (BASED ON THE 2021
UNIFORM PLUMBING CODE)
REHABILITATION:
1. IT IS THE OWNER'S INTENT TO PERFORM THE REHABILITATION WITHIN THE
LIMITS WORK AREA WHILE THE BUILDINGS ARE OCCUPIED.
2. IT IS THE OWNER'S INTENT TO PERFORM A REHABILITATION OF IDENTIFIED
EXTERIOR CLADDING, WINDOWS, DOORS, AND ROOF AREAS AS
DESIGNATED FOR EACH EXISTING BUILDING AS ONE SINGLE PHASE OF
WORK. CONTRACTOR SHALL COORDINATE WITH THE OWNER FOR
SCHEDULE, PHASING, AND WORK.
3. BUILDING REHABILITATION MAY NOT OCCUR IN NUMERICAL ORDER AS
RELATED TO SITE LAYOUT OR BUILDING DESIGNATION.
4. REFER TO THE SITE PLAN AND PROJECT MANUAL FOR NOTES, ASSUMED
LIMITS OF WORK, AND FULL SUMMARY OF WORK.
PROJECT CODE ANALYSIS: PROJECT DESCRIPTION:
1. THE OREGON DEPARTMENT OF FORESTRY ASTORIA DISTRICT CAMPUS IN
ASTORIA OREGON IS A COMPOUND OF SEVEN (7) FACILITY OPERATIONS
BUILDINGS. BUILDINGS WITHIN THE COMPOUND HAVE VARIED YEARS OF
DEVELOPMENT WITH LIMITED DOCUMENTATION RELATING TO ORIGINAL
DESIGN AND CONSTRUCTION. BUILDING ENCLOSURE WORK FOR THIS
PROJECT ARE PRIMARILY DESIGNATED FOR THE MAIN OFFICE BUILDING
HOWEVER EACH BUILDING SHALL RECEIVE IDENTIFIED WORK AS PART OF
THE PROPOSED SCOPE.
2. BUILDING A: MAIN OFFICE - ELEVATIONS ARE SIMILAR IN ASSEMBLY
CONFIGURATIONS, AND ARE PREDOMINANTLY VARIED BY FLOOR LEVEL
ACCESS, SIDING MATERIALS, AND ROOF CONFIGURATION. OF NOTE THE
OFFICE BUILDING UNDERWENT AN EXPANSION AROUND THE YEAR 1997
WHICH INCLUDED A FIRE-RATED AREA SEPARATION WALL BETWEEN THE
ORIGINAL OFFICE BUILDING AND THE NEW OFFICE ADDITION. BUILDING
COMPONENTS ARE A COMBINATION OF HARDBOARD "MASONITE"
COMPOSITE LAP SIDING WITH METAL CORNER CLOSURE PIECES ON THE
ORIGINAL STRUCTURE AND FIBER CEMENT PLANK LAP SIDING AND TRIM
ON THE ADDITION. TRIM VARIES WITH BOTH FIBER CEMENT AND WOOD
FENESTRATION TRIM MEMBERS. THE BUILDING ROOF AREAS ARE PITCHED
ROOF AND GABLE CONFIGURATIONS WITH OVERHANGS AND ARE CLAD IN
COMPOSITION ASPHALT SHINGLE ROOFING.
2.1. THE PROPOSED BUILDING ENCLOSURE REHABILITATION SHALL
CONSIST OF REMOVAL, DISPOSAL, AND REPLACEMENT ALL EXISTING
SIDING AND TRIM ALONG EACH BUILDING ELEVATION AND INCLUDE
CONCEALED WRB AND FLASHINGS. REMOVAL, DISPOSAL, AND
REPLACEMENT OF ALL EXISTING WINDOW UNITS. REMOVAL AND
REINSTALLATION OF ALL EXISTING SWING DOOR UNITS. REMOVAL,
DISPOSAL, AND REPLACEMENT OF 100% OF EXISTING ROOF
CLADDINGS INCLUDING UNDERLAYMENT AND FLASHINGS. EXISTING
GUTTERS AND DOWNSPOUTS TO BE REMOVED AND REINSTALLED.
100% REMOVAL AND REPLACEMENT OF (2) LAYERS OF GYPSUM
WALLBOARD SHEATHING AT ABOVE ROOF AREAS OF RATED
PARTITION WALL (TYPICAL EACH SIDE) .
3. BUILDING B AND C: MECHANIC'S SHOP - ELEVATIONS ARE SIMILAR IN
ASSEMBLY COMPONENTS AND CONSIST OF FIBER CEMENT PLANK LAP
CLADDING AND TRIM, FLANGED VINYL WINDOWS, METAL CLAD SWING
DOORS, AND COMPOSITION ASPHALT SHINGLE ROOFING ASSEMBLIES
WITH METAL FLASHINGS.
3.1. THE PROPOSED BUILDING ENCLOSURE REHABILITATION SHALL
CONSISTS TARGETED REPAIR WORK TO THE EXISTING ROOF
ASSEMBLY AND MAY INCLUDE REMOVAL AND REPLACEMENT OF
EXISTING ASPHALT SHINGLE ROOFING AND FLASHING COMPONENTS.
4. BUILDING D: PUMPER SHED - ELEVATIONS ARE SIMILAR IN ASSEMBLY
COMPONENTS AND CONSIST OF A COMBINATION OF T1-11 PLYWOOD
SIDING AND FIBER CEMENT PLANK LAP CLADDING, (1) FLANGED ALUMINUM
AND (1) VINYL WINDOW ASSEMBLY, TRANSLUCENT FIBERGLASS AND
METAL ROLL UP DOOR ASSEMBLIES, AND COMPOSITION ASPHALT SHINGLE
ROOFING ASSEMBLIES WITH METAL FLASHINGS.
4.1. THE PROPOSED BUILDING ENCLOSURE REHABILITATION SHALL
CONSIST OF REMOVAL, DISPOSAL, AND REPLACEMENT OF ALL ROOF
CLADDINGS INCLUDING UNDERLAYMENT, FLASHINGS, GUTTERS AND
DOWNSPOUTS.
5. BUILDING E: OLD PRESERVATION BUILDING - ELEVATIONS ARE SIMILAR IN
ASSEMBLY COMPONENTS AND CONSIST OF FIBER CEMENT SIDING, LIMITED
PROTECTED AREAS OF T1-11, CEDAR TRIMS AND MOUNTING BLOCKS,
PANEL CLAD WOOD DOORS, METAL ROLL UP DOOR, AND COMPOSITION
ASPHALT SHINGLE ROOFING ASSEMBLIES WITH METAL FLASHINGS.
5.1. THE PROPOSED BUILDING ENCLOSURE REHABILITATION SHALL
CONSISTS TARGETED REPAIR WORK TO THE EXISTING ROOF
ASSEMBLY AND MAY INCLUDE REMOVAL AND REPLACEMENT OF
EXISTING ASPHALT SHINGLE ROOFING AND FLASHING COMPONENTS..
GENERAL NOTES: GENERAL NOTES, CONT.:
1. READ DESIGN DOCUMENTS (DRAWINGS) IN CONJUNCTION WITH THE
PROJECT MANUAL (PRODUCT SPECIFICATIONS).
2. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS ON SITE.
3. DRAWINGS OF ELEVATIONS AND SITE PLANS OF THE PROJECT ARE
REPRODUCED FROM BASE DRAWINGS PREPARED BY ORIGINAL
ARCHITECT. BRING DISCREPANCIES BETWEEN DESIGN DOCUMENTS AND
ACTUAL PROJECT CONDITIONS TO THE IMMEDIATE ATTENTION OF THE
BUILDING ENVELOPE CONSULTANT AND REQUEST A REVIEW.
4. EXECUTION OF THE CONTRACT BY THE CONTRACTOR IS A
REPRESENTATION THAT THE CONTRACTOR HAS VISITED THE SITE,
BECOME GENERALLY FAMILIAR WITH THE LOCAL CONDITIONS UNDER
WHICH THE WORK IS TO BE PERFORMED AND CORRELATED PERSONAL
OBSERVATIONS WITH REQUIREMENTS OF THE CONTRACT DOCUMENTS.
5. ALL WORK TO BE PERFORMED UNDER THIS SCOPE OF REPAIRS (WORK)
SHALL BE CONDUCTED IN FULL COMPLIANCE WITH ALL APPLICABLE
LOCAL, STATE, AND FEDERAL LAWS AND REGULATIONS. IT IS THE
CONTRACTOR'S DUTY TO BE FAMILIAR WITH ALL SUCH APPLICABLE
LOCAL, STATE, AND FEDERAL LAWS AND REGULATIONS. FURTHERMORE,
THE CONTRACTOR SHALL ENSURE THAT ALL ACTIVITIES PERFORMED BY
THE CONTRACTOR'S PERSONAL EMPLOYEES, SUBCONTRACTORS, AND
SUPPLIERS COMPLY WITH THESE LAWS AND REGULATIONS DURING THE
CONSTRUCTION PROCESS.
6. CONTRACT DRAWINGS ARE COMPLIMENTARY, AND WHAT IS REQUIRED
BY ANY ONE SHALL BE BINDING AS IF REQUIRED BY ALL. BEFORE
STARTING EACH PORTION OF THE WORK, CAREFULLY STUDY AND
COMPARE THE VARIOUS DRAWINGS AND OTHER CONTRACT DOCUMENTS
RELATIVE T0 THAT PORTION OF THE WORK, AS WELL AS INFORMATION
FURNISHED BY OWNER. TAKE FIELD MEASUREMENTS OF ANY EXISTING
CONDITIONS RELATED TO THAT PORTION OF THE WORK AND OBSERVE
CONDITIONS AT THE SITE AFFECTING IT. THESE OBLIGATIONS ARE FOR
THE PURPOSE OF FACILITATING CONSTRUCTION BY THE CONTRACTOR
AND NOT FOR THE PURPOSE OF DISCOVERING ERRORS, OMISSIONS, OR
INCONSISTENCIES IN THE CONTRACT DOCUMENTS; HOWEVER, REPORT
ERRORS, OMISSIONS, OR INCONSISTENCIES DISCOVERED BY THE
CONTRACTOR PROMPTLY TO THE CONSULTANT AS A REQUEST FOR
INTERPRETATION IN THE FORM PROVIDED IN THE PROJECT MANUAL.
7. REPORT DISCREPANCIES IN CONTRACT DOCUMENTS TO FORENSIC FOR
CLARIFICATION PRIOR TO COMMENCING WORK.
8. IMMEDIATELY NOTIFY BUILDING ENVELOPE CONSULTANT UPON
DISCOVERY OF ADDITIONAL UNFORESEEN DAMAGE TO EXISTING
CONSTRUCTION SCHEDULED TO REMAIN AND THAT IS OUTSIDE THE
CONTRACT. REQUEST A REVIEW. DO NOT COMMENCE RELATED WORK
TO NEARBY WORK WITHOUT CONSULTANT APPROVAL.
9. TRADE CONTRACTORS ARE RESPONSIBLE FOR THE LAYOUT OF THEIR
OWN WORK, AND TO SEE THAT ITS WORK COMES TOGETHER WITH THAT
OF OTHERS. REPORT DISCREPANCIES ON DRAWINGS TO BUILDING
ENVELOPE CONSULTANT FOR DECISIONS.
10. TRADE CONTRACTORS MUST ASSURE THEMSELVES THAT THEY HAVE
THE LATEST DRAWINGS ISSUED FOR CONSTRUCTION, SPECIFICATIONS,
MANUFACTURERS' INSTALLATION INSTRUCTIONS AND REFERENCE
STANDARDS IN THE CONTRACTOR'S OFFICE.
11. DURING REMEDIATION WORK, THE CONTRACTOR IS TO VERIFY AND
MAINTAIN RATED WALL ASSEMBLIES AT ALL EXISTING WALL LOCATIONS.
OVERSIGHT IS REQUIRED BY A LICENSED STRUCTURAL ENGINEER TO
PROVIDE FRAMING AND SHEATHING CONDITIONS ASSESSMENT
INCLUDING RATED WALLS WHERE REPAIR WORK IS IDENTIFIED DURING
ACTUAL WORK ON THE PROJECT. THE CONTRACTOR IS TO PROVIDE
AREA SPECIFIC ENGINEERED DRAWINGS SHOWING EXTENT, DETAILS,
AND CALCULATIONS TO THE AUTHORITY HAVING JURISDICTION FOR
REVIEW AND APPROVAL PRIOR TO REMEDIATION WORK.
CONCEALED BARRIER INSTALLATION:
1. CLEAN AND PREPARE SURFACES PRIOR TO INSTALLATION OF ALL
MEMBRANES IN ACCORDANCE TO PRODUCT MANUFACTURERS'
RECOMMENDATIONS AND AS DIRECTED BY BUILDING ENCLOSURE
CONSULTANT.
2. CONTRACTOR TO PROVIDE ISOMETRIC FLEXIBLE SADDLE
FLASHINGS AT MULTI-PLANE WALL, WALL OPENING, ROOF
TRANSITION, AND DECK TRANSITION AREAS AS OCCURS AND AS
DETAILED PER DESIGN DOCUMENTS.
MEMBRANE INSTALLATION:
1. SEAL WEATHER-RESISTIVE BARRIER AT ALL LAPS AND
TERMINATIONS TO CREATE AIR BARRIER. NOT ALL SEALANT
LOCATIONS ARE ILLUSTRATED.
2. PROVIDE FURRING STRIPS/RAIN SCREEN BEHIND ALL EXTERIOR
CLADDING AND TRIM IN ACCORDANCE WITH THE DRAWINGS,
SPECIFICATIONS, AND MANUFACTURER'S WRITTEN
INSTRUCTIONS.
METAL FLASHING:
1. PROVIDE AND INSTALL METAL HEAD FLASHING WITH FOLDED,
UPTURNED END DAMS OVER WINDOW, DOOR, AND SLIDING
GLASS DOORS TRIM. CONTRACTOR TO FIELD VERIFY THAT METAL
HEAD FLASHING DOES NOT INTERFERE WITH OPERATION OF THE
FENESTRATION.
2. FORM 100% OF THROUGH-WALL AND HEAD FLASHINGS WITH A
SLOPED HORIZONTAL SURFACE CONFORMING TO THE
FOLLOWING CRITERIA:
· ENSURE A 5% SLOPE AT GREATER THAN OR EQUAL TO A
1-1/2" WIDE HORIZONTAL SURFACE
· ENSURE A 10% SLOPE AT LESS THAN A 1-1/2" WIDE
HORIZONTAL SURFACE
3. CONTRACTOR TO PROVIDE 3-DIMENSIONAL METAL SADDLE
FLASHINGS AT MULTI-PLANE SUBSTRATE INTERSECTIONS, ROOF
TRANSITIONS, WALLS TRANSITIONS, DECK TRANSITIONS, AND AT
OTHER SIMILAR LOCATIONS AS OCCURS AND AS DETAILED PER
DESIGN DOCUMENTS.
EXTERIOR OPENINGS AND PENETRATIONS:
1. ALL SCHEDULES AND QUANTITIES OF WINDOWS, DOORS, VENT
PENETRATIONS, AND EXTERIOR FIXTURES, SUCH AS LIGHT
FIXTURES, CONVENIENCE RECEPTACLES, EXHAUST VENTS, PIPE
PENETRATIONS, HOSE BIBBS, ELECTRICAL OR METERS, ETC.,
THAT HAVE BEEN PROVIDED IN THE DOCUMENTS ARE
APPROXIMATE AND MUST BE VERIFIED BY THE CONTRACTOR ON
SITE. CONTRACTOR SHALL PERFORM OWN QUANTITY SURVEY
AND VERIFIED QUANTITIES OF ALL ITEMS INDICATED IN THE
DRAWINGS.
2. SEAL EXTERIOR WALL PENETRATIONS FOR AIR BARRIER
CONTINUITY WITH SCHEDULED MINIMALLY EXPANDING FOAM
INSULATION.
3. FORM EXTERIOR PERIMETER DYNAMIC SEALANT JOINTS, 1/2"
WIDE TYPICAL, WITH CONTINUOUS CLOSED CELL BACKER ROD
U.O.N., ENSURE BACKER ROD DIAMETER EXCEEDS JOINT WIDTH
BY 25% AND MAINTAIN A JOINT WIDTH-TO-DEPTH RATIO OF 2:1.
GENERAL NOTES, CONT.:
DRAWING TERMS:
1. DEMOLISH: (DEMO) TO COMPLETELY REMOVE AND LEGALLY
DISPOSE OF OFF-SITE IN A MANNER COMPLIANT WITH FEDERAL,
STATE, AND LOCAL PROTOCOLS.
2. SCHEDULED (ITEM): COMPONENTS CALLED OUT AS SCHEDULED
SHALL REMAIN IN PLACE, BE REMOVED AND REINSTALLED, BE
REMOVED AND REPLACED, BE INSTALLED AS A NEW
COMPONENT, OR REPLACED IF DAMAGED IS DISCOVERED.
REFER TO PROJECT MANUAL FOR CONDITION, ASSEMBLIES, AND
RELATED MATERIALS.
3. PROTECT (ITEM): A TERM USED ON DRAWINGS TO INDICATE AN
ITEM REQUIRES PROTECTION FROM THE WORK.
4. REMOVE (ITEM): A TERM USED ON DRAWINGS TO INDICATE A
SPECIFIC ITEM TO BE DETACHED FROM EXISTING CONSTRUCTION
AND LEGALLY DISPOSED OF OFF-SITE, UNLESS INDICATED
OTHERWISE TO BE REMOVED, SALVAGED, AND REINSTALLED.
5. REMOVE AND REINSTALL (ITEM): A TERM USED ON DRAWINGS TO
INDICATE A SPECIFIC ITEM TO BE DETACHED FROM EXISTING
CONSTRUCTION, PREPARED FOR REUSE, AND REINSTALLED
BACK IN ITS EXISTING LOCATION.
6. RELOCATE (ITEM): A TERM USED IN DRAWINGS TO INDICATE AN
EXISTING ITEM THAT HAS BEEN REMOVED, AND TO BE
REINSTALLED IN A NEW LOCATION
7. SALVAGE (ITEM): CAREFULLY DETACH FROM EXISTING
CONSTRUCTION, IN A MANNER TO PREVENT DAMAGE READY FOR
REUSE. INCLUDE FASTENERS OR BRACKETS NEEDED FOR
REATTACHMENT IN ORIGINAL LOCATION OR ELSEWHERE.
8. EXISTING TO REMAIN (ITEM): A TERM USED ON DRAWINGS TO
INDICATE EXISTING ITEMS OF CONSTRUCTION THAT ARE NOT BE
REMOVED AND THAT ARE NOT OTHERWISE INDICATED TO BE
REMOVED, SALVAGED, OR REMOVED AND REINSTALLED.
EXISTING TO REMAIN IS INDICATED BY GRAPHIC LINETYPE
SYMBOL.
9. PHASE: A PORTION OF THE WORK TO BE COMPLETED DURING A
SET PERIOD OF TIME, AS DEFINED IN THE PROJECT
SPECIFICATIONS.
10. REFER TO SPECIFICATIONS SUMMARY OF WORK, GENERAL
DESCRIPTION OF WORK, FOR SCOPE OF REPAIR ASSEMBLIES.
ALUM. ALUMINUM
APPROX. APPROXIMATE
ARCH. ARCHITECTURAL
BLDG. BUILDING
BOT BOTTOM
COL. COLUMN
CONC. CONCRETE
CONT. CONTINUOUS
CONST. CONSTRUCTION
C/W COMPLETE WITH
DIA. DIAMETER
DEFS DIRECT-APPLIED
FINISH SYSTEM
DIM. DIMENSION
DWG DRAWING
DS DOWNSPOUT
E. EAST
EA. EACH
ELEV. ELEVATION
ELEC. ELECTRICAL
EIFS EXTERIOR INSULATION &
FINISH SYSTEM
EQ. EQUAL
EQUIP. EQUIPMENT
EXIST. EXISTING
EXT. EXTERIOR
FC FIBER CEMENT
FIN. FINISH
ABBREVIATIONS:
F.O.S. FACE OF STUD
FLR. FLOOR
FRTW FIRE-RETARDANT
TREATED WOOD
FURR FURRING OR FURRED
GA GAUGE
GALV. GALVANIZED
GWB GYPSUM WALL BOARD
GYP. GYPSUM
HORIZ. HORIZONTAL
INT. INTERIOR
INSUL. INSULATION
MAX MAXIMUM
MEMB. MEMBRANE
MTL METAL
MIN. MINIMUM
MISC. MISCELLANEOUS
N. NORTH
N.I.C. NOT IN CONTRACT
(NOT IN SCOPE)
NTS NOT TO SCALE
O.C. ON CENTER
PLY PLYWOOD
P.T. PRESSURE TREATED (POST-TENSIONED
WHEN USED WITH CONCRETE)
R RADIUS
REF. REFERENCE
REINF REINFORCED
REQ'D REQUIRED
RD ROOF DRAIN
S. SOUTH
SAM SELF ADHESIVE
MEMBRANE (FLASHING)
SECT. SECTION
SIM. SIMILAR
SPEC SPECIFICATION
S.S. STAINLESS STEEL
STRUCT. STRUCTURAL
T&G TONGUE AND GROOVE
TBD TO BE DETERMINED
TEMP TEMPERATURE
T.O.W. TOP OF WALL
TYP. TYPICAL
U.O.N. UNLESS OTHERWISE NOTED
VERT. VERTICAL
V.I.F. VERIFY IN FIELD
W. WEST
W/ WITH
W/O WITHOUT
WRB WEATHER-RESISTIVE
BARRIER
GYPSUM SHEATHING / GYPSUM WALLBOARD
BATT INSULATION
DETAIL HATCH PATTERN LEGEND:
TYPICAL LINE WEIGHT OF 'NEW' BUILDING ENVELOPE
COMPONENTS - WALLS, WINDOWS, DOORS, ETC.
SAM - SELF APPLIED MEMBRANE FLEXIBLE FLASHING,
OR MANUFACTURED FLASHING PANELS AS NOTED
WRB - WEATHER RESISTIVE BARRIER
MISC. COMPONENTS - DRAINAGE MAT, REINFORCING
MESH, BUG SCREEN, FASTENERS, SCREWS, NAILS
EXISTING ROOF UNDERLAYMENT, OTHER EXISTING
COMPONENTS
METAL FLASHING
SEALANT / ADHESIVE LAYER
LINETYPE LEGEND:
FIBER CEMENT CLADDING / CEMENT
BOARD / TILE ADHESIVE
CONCRETE
DECK COATING REINFORCEMENT MESH
DRAINAGE MAT
ACRYLIC REINFORCED CEMENTITIOUS DECK
COATING SYSTEM
POLYURETHANE DECK COATING / CONCRETE
DAMP-PROOFING
RIGID INSULATION / FOAM
STEEL / METAL
SCHEDULED WRB
SCHEDULED SAM
METAL FLASHING, COPING, AND SADDLES
APPLIED DECK COATING SYSTEM
SCHEDULED SEALANT
ISOMETRIC DETAIL HATCH PATTERN LEGEND:
TYPICAL LINE WEIGHT OF EXISTING BUILDING
ENVELOPE COMPONENTS
DYNAMIC SEALANT JOINT: SEALANT APPLIED OVER
CLOSED CELL BACKER ROD (2:1 RATIO)
CONTINUOUS SEALANT BEAD
PLYWOOD SHEATHING
PROJECT TEAM:
Buildings D, E, F, & G - Easterly View
PROJECT PARAMETERS:
1. UNLESS ACCOMPANIED BY DOCUMENTATION STAMPED BY A LICENSED
PROFESSIONAL, THE WORK DESCRIBED WITHIN THESE CONTRACT
DOCUMENTS SHALL NOT INCLUDE THE FOLLOWING CRITERIA (REFER TO
ORS 671.030d):
· THE STRUCTURAL PART OF THE BUILDING, INCLUDING BUT NOT
LIMITED TO THE FOUNDATION WALLS, FLOORS, ROOF, FOOTINGS,
BEARING PARTITIONS, BEAMS, COLUMNS AND JOISTS, IS NOT
INVOLVED;
· THE BUILDING CODE CLASSIFICATION BY USE OR OCCUPANCY OF
THE BUILDING IS NOT CHANGED; AND
· THE BUILDING CODE CLASSIFICATION BY TYPE OF CONSTRUCTION
OF THE BUILDING IS NOT CHANGED.
2. NON-STRUCTURAL WORK DESCRIBED WITHIN THESE CONTRACT
DOCUMENTS SHALL FALL UNDER EXCEPTIONS: 2 OF OSSC 107.1IN THAT
PLANS, SPECIFICATIONS, CALCULATIONS, DIAGRAMS AND OTHER DATA
PREPARED AND DESIGNED BY AN ENGINEER OR ARCHITECT LICENSED
BY THE STATE TO PRACTICE AS SUCH ARE NOT REQUIRED FOR THE
FOLLOWING WORK:
· 2.3 ALTERATIONS OR REPAIRS THAT DO NOT INVOLVE THE
STRUCTURAL PARTS OF THE BUILDING.
3. IT IS RECOGNIZED THAT THERE MAY BE SEPARATE TRADE PERMITS
RELATED TO PLUMBING OR UTILITY EXTENSIONS AND/OR MINOR
RECONFIGURATIONS OF EXTERIOR VENTILATION AND ELECTRICAL
PENETRATIONS RELATED TO THIS REHABILITATION PROJECT. IT IS
UNLIKELY THAT MECHANICAL AND/OR FIRE LIFE SAFETY SYSTEMS
INCLUDING ALARMS OR FIRE SPRINKLER SYSTEMS WILL BE AFFECTED.
CLIENT:
Oregon Department of Forestry 2600 State Street Salem, OR 97310 Contact: Joseph Pfau Phone: 503.507.1527 email: joseph.j.pfau@odf.oregon.gov
BUILDING ENVELOPE CONSULTANT:
Forensic Building Consultants 12901 SE 97th Ave., Suite 310 Clackamas, OR 97015 Phone: 503.772.1114 Contact: Jordon Wyatt, Project Manager email: jordon@forensicbuilding.com
Michael Green, Technical Design Manager email: michaelg@forensicbuilding.com
AUTHORITY HAVING JURISDICTION:
Clatsop County Building Permits 800 Exchange St., Ste. 100 Astoria, OR 97103 Building and Inspections: 503.338.3697 email:BuildingDivision@clatsopcounty.gov https://www.clatsopcounty.gov/building
Building D: Tanker/Engine Garage/Workshop - South Elevation View Building A: Main Office Building - East Elevation View
CONTRACTOR:
92219 OR-202 Astoria, OR 97103
PROJECT BASIS OF DESIGN
1. PROJECT BASE BID SCOPE OF REPAIR WORK COMPONENTS TO INCLUDE
THE FOLLOWING AREAS OF WORK:
· REMOVE AND DISPOSE OF HARDBOARD AND FIBER CEMENT
WALL CLADDING COMPONENTS
· REMOVE AND DISPOSE OF VINYL WINDOW ASSEMBLIES
· REMOVE AND STORE SWING DOOR ASSEMBLIES
· REMOVE AND DISPOSE OF ASPHALT SHINGLE ROOFING
· REMOVE AND DISPOSE OF METAL PARAPET COPING
· REMOVE AND DISPOSE OF EXPOSED PORTIONS OF EXISTING
MASONRY BRICK CHIMNEY, BOILER VENT STACK, AND
ASSOCIATED FLASHING COMPONENTS
2. SCHEDULED PROJECT COMPONENTS INCLUDE, BUT ARE NOT LIMITED TO:
· WOOD FRAMING AND FURRING MEMBERS
· BATT, FOAM, AND CELLULOSE INSULATION (TO MATCH
EXISTING)
· PLYWOOD AND GYPSUM WALLBOARD SHEATHING
· CODE COMPLIANT WEATHER-RESISTIVE BARRIER (WRB)
AND FLEXIBLE SAM FLASHING
· FIBER CEMENT PLANK LAP CLADDING, TRIM MEMBERS, AND
MOUNTING BLOCKS
· FLANGED VINYL WINDOWS
· ALUMINUM GUTTERS AND DOWNSPOUTS
· METAL PARAPET COPING, TRANSITION FLASHING, AND
THREE-DIMENSIONAL METAL SADDLE FLASHINGS
· SCHEDULED SEALANTS
· EXTERIOR PAINTING
PROJECT DESCRIPTION CONT.:
6. BUILDING F: REFORESTATION WAREHOUSE - ELEVATIONS ARE SIMILAR IN
ASSEMBLY COMPONENTS AND CONSIST OF FIBER CEMENT SIDING,
CEDAR TRIMS AND MOUNTING BLOCKS, (1) METAL ROLL UP DOOR, AND
COMPOSITION ASPHALT SHINGLE ROOFING ASSEMBLIES WITH METAL
FLASHINGS.
6.1. THE PROPOSED BUILDING ENCLOSURE REHABILITATION SHALL
CONSISTS TARGETED REPAIR WORK TO THE EXISTING ROOF
ASSEMBLY AND MAY INCLUDE REMOVAL AND REPLACEMENT OF
EXISTING ASPHALT SHINGLE ROOFING AND FLASHING
COMPONENTS.
7. BUILDING G: PROTECTION WAREHOUSE/OFFICE - ELEVATIONS ARE
SIMILAR IN ASSEMBLY COMPONENTS AND CONSIST OF A COMBINATION
OF T1-11 PLYWOOD SIDING AND FIBER CEMENT PLANK LAP CLADDING, (1)
FLANGED ALUMINUM WINDOW ASSEMBLY, METAL ROLL UP DOOR
ASSEMBLIES, PANEL CLAD SWING DOOR UNITS, AND COMPOSITION
ASPHALT SHINGLE ROOFING ASSEMBLIES WITH METAL FLASHINGS.
7.1. THE PROPOSED BUILDING ENCLOSURE REHABILITATION SHALL
CONSISTS TARGETED REPAIR WORK TO THE EXISTING ROOF
ASSEMBLY AND MAY INCLUDE REMOVAL AND REPLACEMENT OF
EXISTING ASPHALT SHINGLE ROOFING AND FLASHING
COMPONENTS.
8. BUILDING H: CHEMICAL STORAGE WAREHOUSE - ELEVATIONS ARE
SIMILAR IN ASSEMBLY COMPONENTS AND CONSIST OF A COMBINATION
OF T1-11 PLYWOOD SIDING, FIBER CEMENT PLANK LAP CLADDING, AND
TRANSLUCENT FIBERGLASS PANELS, (2) FLANGED ALUMINUM WINDOW
ASSEMBLY, (2) METAL ROLL UP DOOR ASSEMBLIES, (2) PANEL CLAD
SWING DOOR UNITS, AND COMPOSITION ASPHALT SHINGLE ROOFING
ASSEMBLIES WITH METAL FLASHINGS.
8.1. THE PROPOSED BUILDING ENCLOSURE REHABILITATION SHALL
CONSIST OF REMOVAL, DISPOSAL, AND REPLACEMENT OF ALL ROOF
CLADDINGS INCLUDING UNDERLAYMENT, FLASHINGS, GUTTERS AND
DOWNSPOUTS.
A0.00
COVER SHEET
CODE ANALYSIS
PROJECT DESCRIPTION
05.14.2025
SHEET NAME
REVISIONS
ISSUE
REV. DATE
PROJECT NAME
CLIENT
PROJECT NUMBER
SHEET NUMBER
15 82nd Drive, Suite 10 Gladstone, OR 97027
TEL: 503.772.1114
FAX: 503.772.4039
www.forensicbuilding.com info@forensicbuilding.com
COPYRIGHT ©2025 FORENSIC
BUILDING CONSULTANTS
All Rights Reserved
PRINT ALL DETAILS IN
COLOR AT 24x36
OR CCB# 155496
WA FORENW C94308
UT #8334529-5501
(RE) 25-062
Permit Issue Set
Bidding Issue Addenda - 06.26.2026
O re go n
D ep ar tm en t o f F or es try
A st or ia
D is tri ct
B ui ld in g
- R oo f a nd S id in g R eh ab ili ta tio n
(P O
-6
-0
8)
O re go n
De pa rtm en t o f F or es try
S ta te
S tre et , B ui ld in g
F, S al em
, O R
O
R -2
A st or ia , O
R
2 BUILDING 'B' AND 'C' ROOF PLAN
1/8" = 1'-0" mhg
ROOF PLAN KEYNOTES:
ROOF PLAN NOTES:
1. COORDINATE ROOF DEMOLITION WITH SCHEDULED WORK AT ADJACENT EXTERIOR WALL CLADDING
INTEGRATION WORK PER THE DESIGN DOCUMENTS AND ACCOMPANYING PROJECT MANUAL. PERFORM
SELECTIVE AND LIMITED DEMOLITION OF EXISTING WALL ASSEMBLIES AS REQUIRED.
2. VERIFY CLEARANCE REQUIREMENTS AND MATCH ASSEMBLY OF EXISTING FIRE RATED WALLS AND ROOF
SYSTEMS WHERE REPAIRED DURING THE COURSE OF REQUIRED WORK.
3. REPLACE EXTERIOR PLYWOOD AND GYPSUM WALLBOARD SHEATHING AS NECESSARY TO PERFORM REQUIRED WORK AND AS NECESSARY TO CHASE DAMAGE TO EXTINCTION. PATCH, REPAIR, AND MATCH
PLANE OF EXISTING ADJACENT SURFACES.
4. PLANS HAVE BEEN CREATED USING INFORMATION REPRODUCED FROM INFORMATION ACQUIRED FROM PUBLIC RECORD, THIRD PARTY DATA SETS, AND/OR PREPARED BY ORIGINAL/PREVIOUS ARCHITECT, DESIGNER, AND/OR CONSULTANT. PLANS ARE FOR REFERENCE TO EXISTING CONDITIONS, WALL LOCATIONS, AND FENESTRATIONS ONLY. BRING ANY DISCREPANCIES BETWEEN DESIGN DOCUMENTS AND ACTUAL PROJECT CONDITIONS TO THE IMMEDIATE ATTENTION OF THE BUILDING ENCLOSURE CONSULTANT AND
REQUEST A REVIEW.
5. CONTRACTOR TO VERIFY VENTILATION OF EXISTING BUILDING ATTIC AREA FOR VENTILATION REQUIREMENTS.
INSTALL ADDITIONAL INTAKE AT EAVE AND UPPER ROOF EXHAUST LOCATIONS AS REQUIRED.
6. CONTRACTOR SHALL MAKE REQUIRED REPAIRS TO EXISTING RATED DRAFT STOP ASSEMBLIES TO ENSURE
CONTINUOUS FIRE RATING FOR EACH EXISTING ATTIC AREA.
ROOF PLAN LEGEND:
REMOVE AND DISPOSE OF 100% OF EXISTING COMPOSITION ASPHALT SHINGLE
ROOFING, UNDERLAYMENT, STATIC VENTS, EXHAUST VENTS, AND ASSOCIATED ROOF
AND FLASHING COMPONENTS. INSTALL SCHEDULED COMPOSITION ASPHALT SHINGLE
ROOFING, UNDERLAYMENT, AND ASSOCIATED COMPONENTS PER DESIGN DOCUMENT
ROOF DETAILS AND PROJECT MANUAL.
INSTALL SCHEDULED ROOF GUTTERS AT ROOF EAVE LOCATIONS WITH DOWNSPOUTS
AND CLEANOUT LOCATED TO TIE INTO EXISTING SITE STORM SEWER LOCATIONS.
REFER TO DESIGN DOCUMENT PACKAGE AND PROJECT MANUAL.
STATIC STEMMED ROOF VENT ASSEMBLY, CONTRACTOR TO ACCOUNT FOR TIGHT-LINING
100% OF BUILDINGS BATH AND KITCHEN LOCATIONS AS OCCURS, REFER TO DETAIL 3/A5.02
PLUMBING VENT STACK ASSEMBLY, REFER TO DETAIL 1/A5.03
SCHEDULED CONTINUOUS RIDGE VENT, REFER TO DETAIL 8/A5.01
APPROXIMATE LOCATION OF STEMMED STATIC ROOF VENT PENETRATION.
EXISTING ROOF SLOPE TO REMAIN.
APPROXIMATE LOCATION OF BOILER EXHAUST STACK PENETRATION.
APPROXIMATE LOCATION OF PLUMBING STACK VENT PENETRATION.
APPROXIMATE LOCATION OF CONTINUOUS RIDGE EXHAUST VENT.
BOILER VENT STACK ASSEMBLY, REFER TO DETAIL 5/A5.02.
1 BUILDING 'A' ROOF PLAN
1/8" = 1'-0" mhg
N
N
APPROXIMATE LOCATION OF TURBINE VENT PENETRATION.
A5.01 TYP.
A5.01 TYP. 1
A3.03
A5.01 TYP.
A5.01 TYP.
A3.03
A5.01TYP.
A3.06 8
A5.01TYP.
A5.02
A5.03
A5.01TYP.
A5.01 TYP.
A5.01 SIM.
A5.--SIM.
A5.01SIM.
A5.01 SIM.
A5.01TYP.
A5.01TYP.
A5.01TYP.
SIM.
2 TYP.
1 TYP.
1 TYP.
2 TYP.
1 TYP.2 TYP.
2TYP.
1TYP.
TYP.
ANTENNA POLE ASSEMBLY AND 3-POINT GUY-WIRE ATTACHMENT, REFER TO VENT PIPE
PENETRATION DETAIL 1/A5.03 FOR SIMILAR (POST BASE) INTEGRATION AND TO DETAIL
7/A5.04 (GUY ANCHOR).
TYP.
A5.02
A5.02
A5.021
A5.02
A3.04
SIM.
A5.04 TYP.
A5.02TYP.
A5.02
A5.02
4'-0" 4'-0"
A5.02 1
A5.02
A5.01 BELOW
A5.04
A5.04SIM.
A5.04TYP.
TARGETED ROOF REHABILITATION AND REPAIRS AT IDENTIFIED LOCATIONS TO BE DETAILED IN SIMILAR FASHION TO CONDITIONS FOR THE FULL ROOFING REPLACEMENT OCCURRING AT BUILDING 'A'. REFER
TO DESIGN PACKAGE FOR RELATED DETAILS AND CORRELATING CONDITIONS.
SIM.
A5.02
SIM. AS
NEEDED
DS APPROXIMATE LOCATION OF EXISTING DOWNSPOUT, CLEANOUT, AND STORM
SEWER TIE-IN OR DAYLIGHT TO GRADE.
DS DSDSDSDS
DSDS
DS
DS
DS DS
DS
DS DS
DS
DSDSDS
DS
DS DS
DS DS
A5.03
SIM. AS
NEEDED
ROOF ANCHOR FALL PROTECTION, REFER TO DETAIL 1/A5.01.
FP
8 NOT USED
9 PROPOSED FALL PROTECTION ROOF ANCHOR , REFER TO DETAIL 7/A5.04. LOCATE
12'-0" O.C. MAX. TYPICAL, EQ. DISTANCE FROM RIDGE ENDS, AND 4'-0" LATERAL
DISTANCE FROM ADJACENT RIDGE.
FP FP FP FP FP FP FP FP FP FP FP
12'-0" O.C. TYP.
EQ.
9TYP.
12'-0" O.C. TYP.
EQ.
9 TYP.
4'- 0"
4'- 0"
FP FP
12'-0" O.C. TYP.
EQ.
4'- 0"
FPFPFPFP
TYP.
ESTIMATED ROOF WORK AT BUILDING 'B & C' SHALL INCLUDE:
· ASSUME REMOVAL AND REPLACEMENT OF 200 SQUARE FEET OF COMPOSITION ASPHALT
SHINGLE ROOFING AND UNDERLAYMENT, MATCHING EXISTING STYLE AND COLOR.
· ASSUME REMOVAL AND REPLACEMENT OF 128 SQUARE FEET OF EXISTING PLYWOOD
ROOF DECK SHEATHING. INSTALLED SHEATHING SHALL BE 5/8" CDX PLYWOOD.
· REPLACEMENT OF WEATHERPROOF FLASHING COLLARS/GASKETS AROUND THREE (3)
VENT PENETRATIONS.
TARGETED REPAIRS:
A1.10
TYPE 1 & 2
ROOF PLANS
05.14.2025
SHEET NAME
REVISIONS
ISSUE
REV. DATE
PROJECT NAME
CLIENT
PROJECT NUMBER
SHEET NUMBER
15 82nd Drive, Suite 10 Gladstone, OR 97027
TEL: 503.772.1114
FAX: 503.772.4039
www.forensicbuilding.com info@forensicbuilding.com
COPYRIGHT ©2025 FORENSIC
BUILDING CONSULTANTS
All Rights Reserved
PRINT ALL DETAILS IN
COLOR AT 24x36
OR CCB# 155496
WA FORENW C94308
UT #8334529-5501
(RE) 25-062
Permit Issue Set
Bidding Issue Addenda - 06.26.2026
O re go n
D ep ar tm en t o f F or es try
A st or ia
D is tri ct
B ui ld in g
- R oo f a nd S id in g R eh ab ili ta tio n
(P O
-6
-0
8)
O re go n
De pa rtm en t o f F or es try
S ta te
S tre et , B ui ld in g
F, S al em
, O R
O
R -2
A st or ia , O
R
1 BUILDING 'D' ROOF PLAN
mhg
2 BUILDING 'E' ROOF PLAN
1/8" = 1'-0" ORIENTATION VARIES
mhg
3 BUILDING 'F' ROOF PLAN
1/8" = 1'-0" mhg
N
N N
A5.01
TYP.
UPPER
A5.01
SIM.
A5.01 SIM.
A5.01SIM.
A5.01 8
A5.01TYP.
A5.01
TYP.
LOWER
A5.--
ROOF PLAN KEYNOTES:
ROOF PLAN NOTES:
1. COORDINATE ROOF DEMOLITION WITH SCHEDULED WORK AT ADJACENT EXTERIOR WALL CLADDING
INTEGRATION WORK PER THE DESIGN DOCUMENTS AND ACCOMPANYING PROJECT MANUAL. PERFORM
SELECTIVE AND LIMITED DEMOLITION OF EXISTING WALL ASSEMBLIES AS REQUIRED.
2. VERIFY CLEARANCE REQUIREMENTS AND MATCH ASSEMBLY OF EXISTING FIRE RATED WALLS AND ROOF
SYSTEMS WHERE REPAIRED DURING THE COURSE OF REQUIRED WORK.
3. REPLACE EXTERIOR PLYWOOD AND GYPSUM WALLBOARD SHEATHING AS NECESSARY TO PERFORM REQUIRED WORK AND AS NECESSARY TO CHASE DAMAGE TO EXTINCTION. PATCH, REPAIR, AND MATCH
PLANE OF EXISTING ADJACENT SURFACES.
4. PLANS HAVE BEEN CREATED USING INFORMATION REPRODUCED FROM INFORMATION ACQUIRED FROM PUBLIC RECORD, THIRD PARTY DATA SETS, AND/OR PREPARED BY ORIGINAL/PREVIOUS ARCHITECT, DESIGNER, AND/OR CONSULTANT. PLANS ARE FOR REFERENCE TO EXISTING CONDITIONS, WALL LOCATIONS, AND FENESTRATIONS ONLY. BRING ANY DISCREPANCIES BETWEEN DESIGN DOCUMENTS AND ACTUAL PROJECT CONDITIONS TO THE IMMEDIATE ATTENTION OF THE BUILDING ENCLOSURE CONSULTANT AND
REQUEST A REVIEW.
5. CONTRACTOR TO VERIFY VENTILATION OF EXISTING BUILDING ATTIC AREA FOR VENTILATION REQUIREMENTS.
INSTALL ADDITIONAL INTAKE AT EAVE AND UPPER ROOF EXHAUST LOCATIONS AS REQUIRED.
6. CONTRACTOR SHALL MAKE REQUIRED REPAIRS TO EXISTING RATED DRAFT STOP ASSEMBLIES TO ENSURE
CONTINUOUS FIRE RATING FOR EACH EXISTING ATTIC AREA.
ROOF PLAN LEGEND:
REMOVE AND DISPOSE OF 100% OF EXISTING COMPOSITION ASPHALT SHINGLE
ROOFING, UNDERLAYMENT, STATIC VENTS, EXHAUST VENTS, AND ASSOCIATED ROOF
AND FLASHING COMPONENTS. INSTALL SCHEDULED COMPOSITION ASPHALT SHINGLE
ROOFING, UNDERLAYMENT, AND ASSOCIATED COMPONENTS PER DESIGN DOCUMENT
ROOF DETAILS AND PROJECT MANUAL.
INSTALL SCHEDULED ROOF GUTTERS AT ROOF EAVE LOCATIONS WITH DOWNSPOUTS
AND CLEANOUT LOCATED TO TIE INTO EXISTING SITE STORM SEWER LOCATIONS.
REFER TO DESIGN DOCUMENT PACKAGE AND PROJECT MANUAL.
STATIC STEMMED ROOF VENT ASSEMBLY, CONTRACTOR TO ACCOUNT FOR TIGHT-LINING
100% OF BUILDINGS BATH AND KITCHEN LOCATIONS AS OCCURS, REFER TO DETAIL 3/A5.02.
PLUMBING VENT STACK ASSEMBLY, REFER TO DETAIL 1/A5.03.
SCHEDULED CONTINUOUS RIDGE VENT, REFER TO DETAIL 8/A5.01.
APPROXIMATE LOCATION OF STEMMED STATIC ROOF VENT PENETRATION.
EXISTING ROOF SLOPE TO REMAIN.
APPROXIMATE LOCATION OF BOILER EXHAUST STACK PENETRATION.
APPROXIMATE LOCATION OF PLUMBING STACK VENT PENETRATION.
APPROXIMATE LOCATION OF TURBINE VENT PENETRATION.
2 TYP.
1 TYP.
2 TYP.1 TYP.
TARGETED ROOF REHABILITATION AND REPAIRS AT IDENTIFIED LOCATIONS TO BE DETAILED IN SIMILAR FASHION TO CONDITIONS FOR THE FULL ROOFING REPLACEMENT OCCURRING AT BUILDING 'A'. REFER
TO DESIGN PACKAGE FOR RELATED DETAILS AND CORRELATING CONDITIONS.
TARGETED ROOF REHABILITATION AND REPAIRS AT IDENTIFIED LOCATIONS TO BE DETAILED IN SIMILAR FASHION TO CONDITIONS FOR THE FULL ROOFING REPLACEMENT OCCURRING AT BUILDING 'A'. REFER
TO DESIGN PACKAGE FOR RELATED DETAILS AND CORRELATING CONDITIONS.
A5.03
TYP. AS
NEEDED
NOT USED
NOT USED
8 CCTV POST ATTACHMENT BRACKET CONDITION, REFER TO DETAIL 3/A3.06.
A5.03 SIM.
TYP.
A5.04
TYP. AS
NEEDED 2
A5.03
TYP. AS
NEEDED
APPROXIMATE LOCATION OF CONTINUOUS RIDGE EXHAUST VENT.
DS APPROXIMATE LOCATION OF EXISTING DOWNSPOUT, CLEANOUT, AND STORM
SEWER TIE-IN OR DAYLIGHT TO GRADE.
DS
DS
DS DS DS
DS
DS
DS
DS
DS DS
DS DS
DS
DS DS
DS
1 TYP.
ROOF ANCHOR FALL PROTECTION, REFER TO DETAIL 1/A5.01.
FP
FP FP
12'-0" O.C. TYP. ℄℄ EQ.9TYP.
4'- 0"
FPFPFPFPFPFPFPFPFP
PROPOSED FALL PROTECTION ROOF ANCHOR , REFER TO DETAIL 7/A5.04. LOCATE
12'-0" O.C. MAX. TYPICAL, EQ. DISTANCE FROM RIDGE ENDS, AND 4'-0" LATERAL
DISTANCE FROM ADJACENT RIDGE.
FP FP
12'-0" O.C. TYP.
EQ.
4'- 0"
FPFPFP
FP
4'-0"
FP
FP
FP
'-0
" O .C
. T
YP
EQ
FPFP
FP
FP
TYP.
TYP.
ESTIMATED ROOF WORK AT BUILDING 'E' SHALL INCLUDE:
· ASSUME REMOVAL AND REPLACEMENT OF 200 SQUARE FEET OF COMPOSITION ASPHALT
SHINGLE ROOFING AND UNDERLAYMENT, MATCHING EXISTING STYLE AND COLOR.
· ASSUME REMOVAL AND REPLACEMENT OF 128 SQUARE FEET OF EXISTING PLYWOOD
ROOF DECK SHEATHING. INSTALLED SHEATHING SHALL BE 5/8" CDX PLYWOOD.
· REPLACEMENT OF WEATHERPROOF FLASHING COLLARS/GASKETS AROUND THREE (3)
VENT PENETRATIONS.
· ASSUME 'LIKE FOR LIKE' REMOVAL AND REPLACEMENT OF 100 LINEAL FEET OF EXISTING
GUTTERS. TIE INTO EXISTING DOWNSPOUT LOCATIONS AS OCCURS.
TARGETED REPAIRS:
ESTIMATED ROOF WORK AT BUILDING 'F' SHALL INCLUDE:
· ASSUME REMOVAL AND REPLACEMENT OF 200 SQUARE FEET OF COMPOSITION ASPHALT
SHINGLE ROOFING AND UNDERLAYMENT, MATCHING EXISTING STYLE AND COLOR.
· ASSUME REMOVAL AND REPLACEMENT OF 128 SQUARE FEET OF EXISTING PLYWOOD
ROOF DECK SHEATHING. INSTALLED SHEATHING SHALL BE 5/8" CDX PLYWOOD.
· REPLACEMENT OF WEATHERPROOF FLASHING COLLARS/GASKETS AROUND THREE (3)
VENT PENETRATIONS.
A1.11
TYPE 3 & 4
ROOF PLANS
05.14.2025
SHEET NAME
REVISIONS
ISSUE
REV. DATE
PROJECT NAME
CLIENT
PROJECT NUMBER
SHEET NUMBER
15 82nd Drive, Suite 10 Gladstone, OR 97027
TEL: 503.772.1114
FAX: 503.772.4039
www.forensicbuilding.com info@forensicbuilding.com
COPYRIGHT ©2025 FORENSIC
BUILDING CONSULTANTS
All Rights Reserved
PRINT ALL DETAILS IN
COLOR AT 24x36
OR CCB# 155496
WA FORENW C94308
UT #8334529-5501
(RE) 25-062
Permit Issue Set
Bidding Issue Addenda - 06.26.2026
O re go n
D ep ar tm en t o f F or es try
A st or ia
D is tri ct
B ui ld in g
- R oo f a nd S id in g R eh ab ili ta tio n
(P O
-6
-0
8)
O re go n
De pa rtm en t o f F or es try
S ta te
S tre et , B ui ld in g
F, S al em
, O R
O
R -2
A st or ia , O
R
1 BUILDING 'G' ROOF PLAN
mhg
1 BUILDING 'H' ROOF PLAN
1/8" = 1'-0" mhg
N N
A5.01
TYP.
A501TYP.
-4
A5.01 TYP.
A5.01TYP
ROOF PLAN KEYNOTES:
ROOF PLAN NOTES:
1. COORDINATE ROOF DEMOLITION WITH SCHEDULED WORK AT ADJACENT EXTERIOR WALL CLADDING
INTEGRATION WORK PER THE DESIGN DOCUMENTS AND ACCOMPANYING PROJECT MANUAL. PERFORM
SELECTIVE AND LIMITED DEMOLITION OF EXISTING WALL ASSEMBLIES AS REQUIRED.
2. VERIFY CLEARANCE REQUIREMENTS AND MATCH ASSEMBLY OF EXISTING FIRE RATED WALLS AND ROOF
SYSTEMS WHERE REPAIRED DURING THE COURSE OF REQUIRED WORK.
3. REPLACE EXTERIOR PLYWOOD AND GYPSUM WALLBOARD SHEATHING AS NECESSARY TO PERFORM REQUIRED WORK AND AS NECESSARY TO CHASE DAMAGE TO EXTINCTION. PATCH, REPAIR, AND MATCH
PLANE OF EXISTING ADJACENT SURFACES.
4. PLANS HAVE BEEN CREATED USING INFORMATION REPRODUCED FROM INFORMATION ACQUIRED FROM PUBLIC RECORD, THIRD PARTY DATA SETS, AND/OR PREPARED BY ORIGINAL/PREVIOUS ARCHITECT, DESIGNER, AND/OR CONSULTANT. PLANS ARE FOR REFERENCE TO EXISTING CONDITIONS, WALL LOCATIONS, AND FENESTRATIONS ONLY. BRING ANY DISCREPANCIES BETWEEN DESIGN DOCUMENTS AND ACTUAL PROJECT CONDITIONS TO THE IMMEDIATE ATTENTION OF THE BUILDING ENCLOSURE CONSULTANT AND
REQUEST A REVIEW.
5. CONTRACTOR TO VERIFY VENTILATION OF EXISTING BUILDING ATTIC AREA FOR VENTILATION REQUIREMENTS.
INSTALL ADDITIONAL INTAKE AT EAVE AND UPPER ROOF EXHAUST LOCATIONS AS REQUIRED.
6. CONTRACTOR SHALL MAKE REQUIRED REPAIRS TO EXISTING RATED DRAFT STOP ASSEMBLIES TO ENSURE
CONTINUOUS FIRE RATING FOR EACH EXISTING ATTIC AREA.
ROOF PLAN LEGEND:
APPROXIMATE LOCATION OF STEMMED STATIC ROOF VENT PENETRATION.
EXISTING ROOF SLOPE TO REMAIN.
APPROXIMATE LOCATION OF BOILER EXHAUST STACK PENETRATION.
APPROXIMATE LOCATION OF PLUMBING STACK VENT PENETRATION.
APPROXIMATE LOCATION OF TURBINE VENT PENETRATION.
2 TYP.
1 TYP.
2TYP.
1TYP.
A5.02
A5.01
TARGETED ROOF REHABILITATION AND REPAIRS AT IDENTIFIED LOCATIONS TO BE DETAILED IN SIMILAR FASHION TO CONDITIONS FOR THE FULL ROOFING REPLACEMENT OCCURRING AT BUILDING 'A'. REFER
TO DESIGN PACKAGE FOR RELATED DETAILS AND CORRELATING CONDITIONS.
4'- 0"
A5.02
SIM. AS
NEEDED
NOT USED
APPROXIMATE LOCATION OF CONTINUOUS RIDGE EXHAUST VENT.
DS APPROXIMATE LOCATION OF EXISTING DOWNSPOUT, CLEANOUT, AND STORM
SEWER TIE-IN OR DAYLIGHT TO GRADE.
DS
DS
DS
DS
DS
DS DS
DS
REMOVE AND DISPOSE OF 100% OF EXISTING COMPOSITION ASPHALT SHINGLE
ROOFING, UNDERLAYMENT, STATIC VENTS, EXHAUST VENTS, AND ASSOCIATED ROOF
AND FLASHING COMPONENTS. INSTALL SCHEDULED COMPOSITION ASPHALT SHINGLE
ROOFING, UNDERLAYMENT, AND ASSOCIATED COMPONENTS PER DESIGN DOCUMENT
ROOF DETAILS AND PROJECT MANUAL.
INSTALL SCHEDULED ROOF GUTTERS AT ROOF EAVE LOCATIONS WITH DOWNSPOUTS
AND CLEANOUT LOCATED TO TIE INTO EXISTING SITE STORM SEWER LOCATIONS.
REFER TO DESIGN DOCUMENT PACKAGE AND PROJECT MANUAL.
STATIC STEMMED ROOF VENT ASSEMBLY, CONTRACTOR TO ACCOUNT FOR TIGHT-LINING
100% OF BUILDINGS BATH AND KITCHEN LOCATIONS AS OCCURS, REFER TO DETAIL 3/A5.02.
PLUMBING VENT STACK ASSEMBLY, REFER TO DETAIL 1/A5.03.
SCHEDULED CONTINUOUS RIDGE VENT, REFER TO DETAIL 8/A5.01.
ROOF ANCHOR FALL PROTECTION, REFER TO DETAIL 1/A5.01.
FP
ANTENNA POLE ASSEMBLY AND 3-POINT GUY-WIRE ATTACHMENT, REFER TO VENT PIPE
PENETRATION DETAIL 1/A5.03 FOR SIMILAR (POST BASE) INTEGRATION AND TO DETAIL
7/A5.04 (GUY ANCHOR).
8 NOT USED
9 PROPOSED FALL PROTECTION ROOF ANCHOR , REFER TO DETAIL 7/A5.04. LOCATE
12'-0" O.C. MAX. TYPICAL, EQ. DISTANCE FROM RIDGE ENDS, AND 4'-0" LATERAL
DISTANCE FROM ADJACENT RIDGE.
FP
FP
'-0
" O .C
. T
YP
EQ
TYP.
4'-0"
FP
FP
FP
FP
FP
FP
FP
'-0
" O .C
. T
YP
EQ
4'-0"
TYP.
ESTIMATED ROOF WORK AT BUILDING 'G' SHALL INCLUDE:
· ASSUME REMOVAL AND REPLACEMENT OF 200 SQUARE FEET OF COMPOSITION ASPHALT
SHINGLE ROOFING AND UNDERLAYMENT, MATCHING EXISTING STYLE AND COLOR.
· ASSUME REMOVAL AND REPLACEMENT OF 128 SQUARE FEET OF EXISTING PLYWOOD
ROOF DECK SHEATHING. INSTALLED SHEATHING SHALL BE 5/8" CDX PLYWOOD.
· REPLACEMENT OF WEATHERPROOF FLASHING COLLARS/GASKETS AROUND THREE (3)
VENT PENETRATIONS.
TARGETED REPAIRS:
A1.12
TYPE 5
ROOF PLAN
05.14.2025
SHEET NAME
REVISIONS
ISSUE
REV. DATE
PROJECT NAME
CLIENT
PROJECT NUMBER
SHEET NUMBER
15 82nd Drive, Suite 10 Gladstone, OR 97027
TEL: 503.772.1114
FAX: 503.772.4039
www.forensicbuilding.com info@forensicbuilding.com
COPYRIGHT ©2025 FORENSIC
BUILDING CONSULTANTS
All Rights Reserved
PRINT ALL DETAILS IN
COLOR AT 24x36
OR CCB# 155496
WA FORENW C94308
UT #8334529-5501
(RE) 25-062
Permit Issue Set
Bidding Issue Addenda - 06.26.2026
O re go n
D ep ar tm en t o f F or es try
A st or ia
D is tri ct
B ui ld in g
- R oo f a nd S id in g R eh ab ili ta tio n
(P O
-6
-0
8)
O re go n
De pa rtm en t o f F or es try
S ta te
S tre et , B ui ld in g
F, S al em
, O R
O
R -2
A st or ia , O
R
3"
'-0
S
C A
LE
F
A C
TO
R
: 4
FILLET BEAD OF SEALANT,
TYPICAL
SCHEDULED SAM, EXTEND FULL HEIGHT
OF VERTICAL TRIM MEMBER, EXTEND
BEYOND TRIM EDGE AS INDICATED
SCHEDULED FIBER CEMENT
PLANK LAP CLADDING
SCHEDULED TRIM - SIZE
PER SPECIFICATIONS -
PRIME PRIOR TO SEALANT
INSTALLATION (TYP.)
1/2" - 1"
CLEAR
DOWNSPOUT (AS OCCURS)
EXISTING SHEATHING
SCHEDULED CODE COMPLIANT DRAINAGE WRB
4 SAME PLANE TRIM WITH BRACKETED
3" = 1'-0" DOWNSPOUT AT FIBER CEMENT CLADDING AND TRIM - PLAN VIEW
mhg
2" TYP.
EA. SIDE
1"
MIN.
1 1/4"
MIN.
4"
1 GRADE BASE OF WALL FLASHING
3" = 1'-0" WITH CLEARANCE AT FIBER CEMENT CLADDING OVER RAINSCREEN CAVITY
mhg
2"
MIN.
EXISTING SHEATHING
SCHEDULED WRB, LAP OVER SAM AND
BASE OF WALL FLASHING BELOW
SCHEDULED FIBER CEMENT PLANK
LAP CLADDING
1/2"
24-GAUGE 316 STAINLESS STEEL
FLASHING WITH BACK HEM
(REFER TO SHEET NOTES)
2"
MIN.
6"
2"
MIN.
CONTINUOUS 3/8" DIA. BEAD OF
SCHEDULED SEALANT
SCHEDULED SAM STARTER STRIP,
REFER TO SHEET NOTES
SCHEDULED PRESSURE TREATED
FURRING STRIPS WITH INSECT SCREENS
AT HORIZONTAL TERMINATIONS
EXISTING GRADE
6"
MIN.
3 BASE OF WALL FLASHING WITH KERF CUT
3" = 1'-0" CONCRETE SLAB AND FIBER CEMENT CLADDING OVER RAINSCREEN CAVITY
mhg
1"
1 1/2"
MIN.
1 1/2"
2"
MIN.
4"
2"
MIN.
1" CLR.
24-GAUGE 316 STAINLESS STEEL
FLASHING SET INTO KERF CUT -
FILL WITH SEALANT PRIOR TO
INSTALLING FLASHING
SAM (REFER TO SHEET NOTES)
CONTINUOUS 3/8" DIA BEAD OF
SEALANT
SCHEDULED SHEATHING
SCHEDULED WRB, LAP OVER SAM
AND BASE OF WALL FLASHING
BELOW AND SEAL
SCHEDULED PRESSURE TREATED
FURRING STRIPS WITH INSECT
SCREENS AT TERMINATIONS
SCHEDULED FIBER CEMENT PLANK
LAP CLADDING
AT GRADE STORM DRAIN
CONNECTION TO
DOWNSPOUT, MODIFY AS
REQUIRED TO ACCOMMODATE
DOWNSPOUT DIAMETER
18" MIN.OR
MATCH EXISTING
METAL DOWNSPOUT FROM
GUTTER ABOVE, MAINTAIN 1/2" - 1"
STANDOFF FROM FIBER CEMENT
CLADDING
SCHEDULED FIBER CEMENT
PLANK LAP CLADDING
6"
MIN.
EXISTING GRADE (SEE
NOTES FOR CONC. WALK)
SCHEDULED PRESSURE
TREATED FURRING STRIPS
WITH INSECT SCREENS AT
TERMINATIONS
2 DOWNSPOUT CLEANOUT ASSEMBLY
3" = 1'-0" AT GRADE CLEARANCE WITH FIBER CEMENT PLANK LAP CLADDING
mhg A3.00 Wall Detals - OFD Astoria District.dwg
PRE-MANUFACTURED AND
PRE-FINISHED METAL
DOWNSPOUT CLEAN-OUT
WITH SS CATCH SCREEN,
INSTALL PER
MANUFACTURER'S
REQUIREMENTS
METAL SCREEN COVER,
POP-RIVET AT FLANGE
AND INSURE A MIN. 15°
ANGLE AND MIN. 3"
VERTICAL OPENING
ABOVE SCREEN FOR
DEBRIS EVACUATION.
TRIM AND CAP SADDLE FLASHING - ISOMETRIC INSET
5 VERTICAL TRANSITION JOINT
3" = 1'-0" AT FIBER CEMENT CLADDING TO EXPOSED CONCRETE - PLAN VIEW
mhg
SAM - LAP OVER WRB ONTO UNDERLYING
SHEATHING AND ADJACENT CONCRETE
FILLET BEAD OF SEALANT (TYP.)
2"
MIN.
2"
MIN.
24-GAUGE 316 STAINLESS
STEEL FLASHING TO CLOSE
END OF CAVITY ON TOP OF
FURRING
2"
MIN.
1/2" DYNAMIC
SEALANT JOINT
(TYP.)
6" MIN.
SIZE TO SUIT
FIELD CONDITIONS
1" CONFIRM DURING MOCK-UP
SEAL EDGE OF SAM
WITH COMPATIBLE
SEALANT
SCHEDULED 5/4 PVC TRIM
SCHEDULED SHEATHING
SCHEDULED WRB
PRESSURE TREATED FURRING STRIPS, TYP.
SCHEDULED FIBER CEMENT PLANK LAP CLADDING
REFER TO
NOTE 8
LINE OF TRIM CAP FLASHING ABOVE
5"
4"
4"
EXTEND 1/2"
BELOW TOP
OF TRIM
4"
24-GAUGE PRE-FINISHED METAL
TRIM CAP SADDLE FLASHING,
INTEGRATE AND LAP WITH WRB
AND BASE OF WALL FLASHING.
(EXTEND OVER TRIM 1" MIN.)
6 INSIDE CORNER TRANSITION JOINT
3" = 1'-0" AT FIBER CEMENT CLADDING TO EXPOSED CONCRETE - PLAN VIEW
mhg
SCHEDULED SAM TO LAP OVER WRB
STATIC FILLET JOINT OF SCHEDULED SEALANT, TYP.
2"
MIN.
1/2" DYNAMIC SEALANT JOINT (TYP.)
24-GAUGE 316 STAINLESS STEEL
FLASHING WITH HEMMED RETURN
SCHEDULED 2x CEDAR TRIM - PRIME
PRIOR TO INSTALLATION, (TYP.)
SCHEDULED WRB
EXISTING SHEATHING
LAP SAM 2" MIN.
ONTO CONCRETE
REFER TO
NOTE 8
SEAL EDGE OF SAM
WITH COMPATIBLE
SEALANT SCHEDULED FURRING STRIPS, TYP.
SCHEDULED FIBER CEMENT PLANK LAP CLADDING
4"
SIZE
TO SUIT
CONDITION 1/2"
SCHEDULED BUTYL-BASED SAM
FLASHING - FULLY WRAP END OF FIN
WALL AND ENSURE CONTINUOUS
COVERAGE FULL WALL HEIGHT
SCHEDULED TRIM, PRIME
ALL FACES PRIOR TO
INSTALLATION, (TYP.)
REMOVE AND REPLACE 100% OF
EXISTING (2) LAYERS OF 5/8"
TYPE 'X' GYPSUM WALLBOARD
SHEATHING, TYPICAL EACH SIDE
OF RATED WALL ASSEMBLY
SCHEDULED WRB, LAP OVER
METAL BASE-OF- WALL
FLASHING BELOW AND SEAL
SCHEDULED FIBER CEMENT
PLANK LAP CLADDING
SCHEDULED WRB
STATIC FILLET JOINT OF
SCHEDULED SEALANT, TYP.
SCHEDULED FIBER CEMENT
PLANK LAP CLADDING
SCHEDULED 2X CEDAR TRIM -
PRIME ALL SIDES PRIOR TO
SEALANT INSTALLATION, (TYP.)
4 1/2"
4 1/2"
SCHEDULED PRESSURE TREATED
FURRING STRIPS WITH INSECT
SCREENS AT TERMINATIONS
EXISTING SHEATHING
STATIC FILLET JOINT OF
SCHEDULED SEALANT, TYP.
4 1/2"
MIN.
NOTE: ENSURE BASE OF WALL FLASHING AT BASE
OF WALL IS CONTINUOUS AROUND END OF WALL
INCLUDING DOWN LEG AT SLAB AS OCCURS
7 PERPENDICULAR RATED PARTITION WALL TRANSITION
3" = 1'-0" WITH FIBER CEMENT CLADDING
mhg
8 RATED PARTITION WALL END CAP DETAIL
3" = 1'-0" WITH FIBER CEMENT CLADDING, TRIM, AND SEALANT
mhg
EXISTING 2x RATED SEPARATION
WALL, EVALUATE FRAMING DURING
DEMOLITION FOR REQUIRED
REPAIRS - REMOVE AND REPLACE
DAMAGED FRAMING, (CHASE
DAMAGE TO EXTINCTION) MATCH
EXISTING SIZE AND SPACING
SCHEDULED MIN. 9" SAM
CENTERED CORNER, TYP.
NOTES:
1. CONTRACTOR TO VERIFY COMPONENT CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES.
2. CAREFULLY REMOVE EXISTING CLADDING, TRIM, WRB, AND ASSOCIATED FLASHINGS ALONG ELEVATION AREAS TO BE
REHABILITATED.
3. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH UPTURNED ENDS AT TERMINATIONS AND CONTINUOUS AROUND
CORNERS. SLOPE HORIZONTAL LEGS TO DRAIN, REFER TO DETAIL 1/A3.01
4. APPLY PRIMER TO CONCRETE SLAB AND FOUNDATION WALL SUBSTRATES PRIOR TO SAM APPLICATION SAM.
5. SHEET METAL FLASHING IS TO FULLY COVER SAM AND ICE AND WATER SHIELD MATERIALS ENTIRELY FROM UV EXPOSURE.
6. INSTALL LOW EXPANDING FOAM AROUND ALL PENETRATIONS TO LIMIT AIR LEAKAGE.
7. IF PENETRATION DOES NOT FALL ALONG FRAMING, INSTALL STRAPPING OR BLOCKING AND INTERMEDIATE FURRING STRIPS
AS NEEDED FOR BLOCK AND SIDING TERMINATIONS.
8. PROVIDE EXTENSIONS WHERE NEEDED TO PIPES, DUCTS, AND OTHER PENETRATIONS TO ACCOMMODATE INCREASED
THICKNESS OF WALL ASSEMBLIES.
9. PRIME AND PREP CLADDING AND TRIM AS REQUIRED TO RECEIVE SEALANT AND PAINT.
10. ISOMETRIC DETAILS ARE INTENDED TO ILLUSTRATE THE RECOMMENDED SEQUENCE OF COMPONENT INSTALLATION AND
GENERAL SHAPE AND PROFILE CONCEPTS OF FLASHING, WATERPROOFING, AND TRANSITION ASSEMBLIES. CERTAIN
ADJACENT COMPONENTS HAVE NOT BEEN ILLUSTRATED FOR DETAIL CLARITY.
11. TREAT ALL CUT EDGES AT PRESSURE-TREATED LUMBER, INCLUDING KERF CUTS, WITH COMPATIBLE TREATMENT SOLUTION
PER AMERICAN WOOD PROTECTION ASSOCIATION - AWPA - M4.
12. REFER TO PROJECT MANUAL, PRODUCT SPECIFICATIONS FOR SCHEDULED COMPONENT ASSEMBLIES.
EXISTING 2x RATED SEPARATION
WALL, EVALUATE FRAMING DURING
DEMOLITION FOR REQUIRED
REPAIRS - REMOVE AND REPLACE
DAMAGED FRAMING, (CHASE
DAMAGE TO EXTINCTION) MATCH
EXISTING SIZE AND SPACING
NOTE: REFER TO DETAIL 8/A5.05 FOR TOP
OF RATED PARTITION WALL CONDITION
REMOVE AND REPLACE 100%
OF EXISTING (2) LAYERS OF
5/8" TYPE 'X' GYPSUM
WALLBOARD SHEATHING,
TYPICAL EACH SIDE OF
RATED WALL ASSEMBLY
1/
2"
'-0
S
C A
LE
F
A C
TO
R
: 8 1"
'-0
S C
A
LE
F A
C
TO
R : 1
A3.02
WALL DETAILS
05.14.2025
SHEET NAME
REVISIONS
ISSUE
REV. DATE
PROJECT NAME
CLIENT
PROJECT NUMBER
SHEET NUMBER
15 82nd Drive, Suite 10 Gladstone, OR 97027
TEL: 503.772.1114
FAX: 503.772.4039
www.forensicbuilding.com info@forensicbuilding.com
COPYRIGHT ©2025 FORENSIC
BUILDING CONSULTANTS
All Rights Reserved
PRINT ALL DETAILS IN
COLOR AT 24x36
OR CCB# 155496
WA FORENW C94308
UT #8334529-5501
(RE) 25-062
Permit Issue Set
Bidding Issue Addenda - 06.26.2026
O re go n
D ep ar tm en t o f F or es try
A st or ia
D is tri ct
B ui ld in g
- R oo f a nd S id in g R eh ab ili ta tio n
(P O
-6
-0
8)
O re go n
De pa rtm en t o f F or es try
S ta te
S tre et , B ui ld in g
F, S al em
, O R
O
R -2
A st or ia , O
R
'-0
S
C A
LE
F
A C
TO
R
: 4 6 TOP-OF-WALL TO GABLE/RAKE FASCIA
3" = 1'-0" WITH FIBER CEMENT PLANK LAP CLADDING
mhg
SEALANT
4" SAM
SCHEDULED PRESSURE TREATED
FURRING STRIPS WITH INSECT
SCREENS AT TERMINATIONS
SCHEDULED WRB
SCHEDULED FIBER CEMENT
PLANK LAP CLADDING
EXISTING SHEATHING
SCHEDULED 5/4 FIBER CEMENT
TRIM - PRIME PRIOR TO SEALANT
INSTALLATION, (TYP.)
FILLET BEAD OF
SEALANT, TYPICAL
2"
MIN.
2"
MIN.
2"
MIN.
2"
MIN.
MIN. 1/4" CLEAR
DO NOT SEAL
SCHEDULED TRIM - PRIME ALL
CUTS PRIOR TO INSTALLATION,
(TYP.)
4" SCHEDULED SAM
COMPATIBLE SEALANT
SCHEDULED PRESSURE TREATED
FURRING STRIPS WITH INSECT
SCREENS AT TERMINATIONS
SCHEDULED WRB
SCHEDULED FIBER CEMENT
PLANK LAP CLADDING
EXISTING SHEATHING
REFER TO ROOF DETAIL 2/A5.01 FOR
REPLACEMENT ROOF ASSEMBLY
COMPONENT ASSEMBLY
EXISTING ROOF EAVE BLOCKING
WITH VENT (AS OCCURS)
EXISTING JOIST FRAMING (BEYOND)
EXISTING ROOF SHEATHING
REFER TO ROOF DETAIL 3/A5.01 FOR
REPLACEMENT ROOF ASSEMBLY
COMPONENT ASSEMBLY
5 TOP-OF-WALL AT EAVE OVERHANG
3" = 1'-0" WITH FIBER CEMENT PLANK LAP CLADDING
mhg
1 RATED PARAPET PARTITION WALL AT ROOF
3" = 1'-0" WITH CAP FLASHING AND FIBER CEMENT PLANK LAP CLADDING
mhg
CONTINUOUS FILLET BEAD OF
SCHEDULED SEALANT - TYP
SCHEDULED FIBER CEMENT
PLANK LAP CLADDING
5/4 x 4 FIBER CEMENT TRIM - PRIME
ALL CUT AND NON-PRIMED FACES
PRIOR TO INSTALLATION, (TYP.) - TRIM
TO BE CONTINUOUS OVER END CAP
WALL TRIM, REFER TO DETAIL 8/A3.02
SCHEDULED WRB, LAP OVER ROOF TO
WALL STEP FLASHING, SAM AND ROOF
UNDERLAYMENT BELOW AND SEAL
REMOVE AND REPLACE 100% OF EXISTING
(2) LAYERS OF 5/8" TYPE 'X' GYPSUM
WALLBOARD SHEATHING, TYPICAL EACH
SIDE OF RATED WALL ASSEMBLY
2"
2"
EXISTING 2x SEPARATION PARAPET
WALL, REPAIR DAMAGED FRAMING
AS REQUIRED, MATCH EXISTING SIZE
AND SPACING
4"
MIN.
SCHEDULED HIGH TEMP SAM - LAP
ONTO ADJACENT SAM 6" MIN. AND OVER
TOP OF WALL ONTO WRB BELOW - DO
NOT PENETRATE WITH FASTENERS
STAINLESS STEEL FASTENERS
WITH NEOPRENE WASHER, TYP.
1"
MIN.
24-GAUGE 316 STAINLESS STEEL OR
ALUMINUM EQUIVALENT PARAPET CAP
FLASHING WITH HEMMED KICK TYPICAL
EACH SIDE
SCHEDULED PRESSURE TREATED
FURRING STRIPS WITH INSECT
SCREENS AT TERMINATIONS, TYP.
CONTINUOUS P.T. NAILER
2 BUILDING A GABLE END ANTENNA / METEOROLOGICAL
3" = 1'-0" EQUIPMENT MOUNT WITH ATTACHMENT AT FASCIA TRIM
mhg
EXISTING ROOF SHEATHING
AND FRAMING
REFER TO ROOF DETAIL
3/A5.01 FOR REPLACEMENT
ROOF ASSEMBLY
COMPONENT ASSEMBLY
6"x6"x1/4"T A36 STEEL WELDED
RIDGE PLATE (MATCH ROOF
PITCH AND CENTER ON RIDGE)
WITH WELDED 1/2" DIA. X 3 1/8"
THREADED ATTACHMENT ROD -
PRE-DRILL PENETRATION AND
FULLY BED IN ROOF MASTIC
NOTES:
1. CONTRACTOR TO VERIFY COMPONENT CLEARANCE REQUIREMENTS AND MAINTAIN ALL RATED WALL ASSEMBLIES.
2. CAREFULLY REMOVE EXISTING CLADDING, TRIM, WRB, AND ASSOCIATED FLASHINGS ALONG ELEVATION AREAS TO
BE REHABILITATED.
3. METAL THRU WALL FLASHING IS TO BE COMPLETE WITH UPTURNED ENDS AT TERMINATIONS AND CONTINUOUS
AROUND CORNERS. SLOPE HORIZONTAL LEGS TO DRAIN, REFER TO DETAIL 1/A3.01
4. APPLY PRIMER TO CONCRETE SLAB AND FOUNDATION WALL SUBSTRATES PRIOR TO SAM APPLICATION SAM.
5. SHEET METAL FLASHING IS TO FULLY COVER SAM AND ICE AND WATER SHIELD MATERIALS ENTIRELY FROM UV
EXPOSURE.
6. INSTALL LOW EXPANDING FOAM AROUND ALL PENETRATIONS TO LIMIT AIR LEAKAGE.
7. IF PENETRATION DOES NOT FALL ALONG FRAMING, INSTALL STRAPPING OR BLOCKING AND INTERMEDIATE
FURRING STRIPS AS NEEDED FOR BLOCK AND SIDING TERMINATIONS.
8. PROVIDE EXTENSIONS WHERE NEEDED TO PIPES, DUCTS, AND OTHER PENETRATIONS TO ACCOMMODATE
INCREASED THICKNESS OF WALL ASSEMBLIES.
9. PRIME AND PREP CLADDING AND TRIM AS REQUIRED TO RECEIVE SEALANT AND PAINT.
10. ISOMETRIC DETAILS ARE INTENDED TO ILLUSTRATE THE RECOMMENDED SEQUENCE OF COMPONENT
INSTALLATION AND GENERAL SHAPE AND PROFILE CONCEPTS OF FLASHING, WATERPROOFING, AND TRANSITION ASSEMBLIES. CERTAIN ADJACENT COMPONENTS HAVE NOT BEEN ILLUSTRATED FOR DETAIL CLARITY.
11. TREAT ALL CUT EDGES AT PRESSURE-TREATED LUMBER, INCLUDING KERF CUTS, WITH COMPATIBLE TREATMENT
SOLUTION PER AMERICAN WOOD PROTECTION ASSOCIATION - AWPA - M4.
12. REFER TO PROJECT MANUAL, PRODUCT SPECIFICATIONS FOR SCHEDULED COMPONENT ASSEMBLIES.
EXISTING ROOF SHEATHING
AND FRAMING
3 BUILDING D CCTV POST ATTACHMENT BRACKET
3" = 1'-0" CONDITION AT EXISTING T1-11 CLADDING
mhg
EXISTING T1-11 PANEL CLADDING, CLEAN AND
PREP AS NECESSARY TO INSTALL BRACKET
AND FLASHED MOUNTING BLOCK (EXISTING
PLANK LAP ON BUILDING 'H' NOT IN SCOPE)
EXISTING WRB (AS OCCURS) TO REMAIN
EXISTING ROOF SHEATHING
AND FRAMING
REPLACEMENT ROOF
ASSEMBLY, REFER TO
DETAIL 4/A5.01 FOR
SCHEDULED COMPONENTS
STATIC FILLET SEALANT JOINT
(TYP. EACH SIDE AND BOTTOM
24-GAUGE 316 STAINLESS STEEL HEAD
FLASHING WITH GUM-LIP SEALANT KICK
SET ON BEAD OF SEALANT - EXTEND 1"
MIN. BEYOND MOUNTING BLOCK
5/4" x 12" x 6" FIBER CEMENT MOUNTING
BLOCK, EXTEND 1" BEYOND EA. BRACKET
SIDE , PRIME ALL FACES PRIOR TO INSTALL
INSTALL MIN. 2x10
BLOCKING AT POST
BRACKET WALL
ATTACHMENT
LOCATIONS, TYP.
CONTINUOUS BUTYL-
BASED SAM BEHIND
MOUNTING BLOCK, TRIM
FLUSH AND FINISH EDGE
WITH COMPATIBLE
SEALANT
4"Wx10"Hx1/4"T A36 STEEL POST
ATTACHMENT BRACKET, PRIME
WITH ZINC-RICH PRIMER AND PAINT
(COLOR AS SELECTED BY OWNER)
3"
1 1/2"
7"
1 1/2"
2"
1/2" 1/2"
1/2"
REFER TO DETAIL 6/A5.02 FOR
SIMILAR WEATHER PROOFING
TREATMENT OF PENETRATION -
MODIFY FLASHING AND
INSTALLED COMPONENTS AS
REQUIRED FOR CONDITION
NOTE: COMPLETED ASSEMBLY TO BE
APPROVED AT TIME OF MOCK-UP
3/8" EPDM SPACER BETWEEN POST
BASE AND BRACKET ANGLE
STAINLESS STEEL U-BOLT AND CLAMP
MOUNT BRACKET - LOCATE AND ATTACH
AT TOP AND BOTTOM FASTENER
POSITIONS, SIZE PER POST DIA.
4"
10"
EXISTING CCTV POST TO BE
REMOVED AND REINSTALLED OR
DISPOSED OF AND REPLACED
PRE-DRILL HOLES
TO ALIGN WITH
U-BOLD FASTENERS
NOTE: DETAIL CONDITION SIMILARLY
AT BUILDINGS G AND H GABLE FASCIA
REFER TO ELEVATION
PHOTOS FOR GABLE
WALL LOUVER VENT
LOCATIONS
1" MIN. THICK SYMAR MASTICATED
FIBER-REINFORCED RUBBER
BEARING PADS - TAPERED SHAPE TO
MATCH ROOF SLOPE AND LOCATE
EA. SIDE OF RIDGE PEAK - CUT TO
SIZE AND PRE DRILL FOR THREADED
FASTENER PASS- THROUGH
FABRICATED 4"Wx24"Hx3/8"T A36
STEEL POST ATTACHMENT ANGLE,
PRIME WITH ZINC-RICH PRIMER
AND PAINT (COLOR AS SELECTED
BY OWNER)
3/8" EPDM SPACER BETWEEN POST
BASE AND BRACKET ANGLE
STAINLESS STEEL U-BOLT AND CLAMP
MOUNT BRACKET - LOCATE AND ATTACH
AT TOP AND BOTTOM FASTENER
POSITIONS, SIZE PER POST DIA.
EXISTING ANTENNA /…
This is the start of the file's text. The full file is on GovTribe.