This is a luminaire catalog specification document from Selux Corporation for the M60 LED Direct/Indirect fixture series, along with supplementary LED strip and lighting component specifications from JESCO Lighting Group and other manufacturers, prepared for the City of West Sacramento's City Hall Outdoor Plaza construction project. The catalog documents provide comprehensive technical specifications, performance data, mounting options, driver configurations, sensor compatibility, and customization details for various LED lighting products that may be incorporated into the plaza's site lighting and electrical systems. The M60 fixture specifications include available lengths from 2 feet to 12 feet with direct and indirect lighting capabilities, multiple lens options (LED Optimized White, Clear Microprism, and LMO variants), mounting methods (cable, stem, and wall mount), and various driver options ranging from basic 0-10V dimming to advanced Lutron EcoSystem and eldoLED drivers. Additional specifications cover JESCO DL-FLEX2-SHE super high-efficacy LED strips (achieving up to 165 lm/W), H.E. Williams 75R and 75S LED narrow strip fixtures, ALW Nova/3 square direct illumination downlights, and OPTOTRONIC OTi 25W programmable LED drivers with dimming capabilities down to 1 percent. All products feature 90+ CRI color rendering, multiple color temperature options (2700K through 5000K), and compatibility with various control systems including wireless sensors, occupancy detection, and daylight harvesting capabilities.
The luminaire specifications indicate standard 5-year limited warranties on LED components with lumen maintenance predictions exceeding 60,000 hours at 90 percent output and L70 ratings greater than 72,000 hours under standard conditions. All products comply with relevant safety certifications including UL and CSA standards for dry and damp location installations, with operating temperature ranges typically from -30°C to 50°C ambient conditions. The specifications include detailed photometric data, efficacy ratings, wattage consumption information organized by fixture length and driver configuration, and comprehensive compatibility charts for various dimming protocols and sensor systems. The documentation provides extensive ordering information with code examples, fixture performance multipliers for different color temperatures and CRI ratings, and installation guidance for field assembly, cable suspension, stem mounting, and wall bracket configurations. Pricing and procurement terms are not detailed within these product specification documents, which serve as reference materials for the project's design and construction phases rather than bid pricing information.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
4340 Redwood Hwy., Suite 245, San Rafael CA 94903
West Sacramento City Hall
Plaza Workspace
Luminaire Catalog Pages
90% CD
August 20. 2025
4340 Redwood Hwy., Suite 245, San Rafael CA 94903
Disclaimer:
The information contained within this luminaire product data package is for reference only. Not all features or options shown on the luminaire product data sheets are included in this project. Please refer to the luminaire schedule for specified product features and options.
Highlighted options are available in standard 4-week lead times from release of order. For other options including mixed orders, consult factory for lead times.
(Rev. 10/2024) L60DI_SS_v4.3
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2024, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
Project:
Type: Qty:
Date: Customer:
M60 LED Direct/Indirect
MI
Clear Lens with Microprism
NB
LMO Symmetric with Satine Lens
A2 LMO Asymmetric 20° Wall Washer with Satine Lens
BW
LMO
Batwing with Satine Lens
A5 LMO Asymmetric 5° Wall Grazer with Satine Lens
MI
Clear Lens with Microprism
WB
LMO Wide Batwing
3 See page 9 for details.
* For mixed mountings consult factory.
AWN
Lutron Athena Wireless Node ready (consult factory)
DC3
Lutron 1% 3-Wire (consult factory)
CA
Casambi Enabled (consult factory)
Order Code:
Series L6DI M60 LED Direct/Indirect
L6DI
L6DI
*�Custom colors are available, please consult factory.
Emergency Options
EC6,7
Emergency Circuit Wiring
6 See page 9 for details.
7 For emergency options with sensors please consult factory.
8 �4’ available with DIM driver only. ≥6’ available with all driver options.
* �Values calculated from a 4’ fixture at 3500K, 90+ CRI using LW shielding and DIM driver.
For additional information please see page 2.
* � �Mixed outputs available 4’ and up.
Configuration Options
Direct Light Engine
CCT 930
3000K
90+ CRI
3500K
90+ CRI
4000K
90+ CRI
Direct Shielding
LW
LED Optimized White Lens
Mounting C Cable
S Swivel Stem
RS
Rigid Stem
W Wall Mount
Nominal Fixture Length
2 ft.
4 ft.
3 ft.
5 ft.
6 ft.
8 ft.
7 ft.
XX
Runs (over 12’) are available in 1’ nominal increments, round up to the nearest foot and replace the “xx” with the # (i.e. 13=13’ nominal).
Finish WH White
SV
Silver
SP
Specify Premium Color
Voltage 1 120 Volt
277 Volt
LED WARRANTY
YEAR
ARRA
Compliant
ADA
Compliant
2700K
90+ CRI
9 ft.
11 ft.
10 ft.
12 ft.
U 120 through 277 50/60hz capable
Indirect Light Engine
Indirect Shielding
LW
LED Optimized white lens
Individual fixtures, Runs, and Configurations are supplied in nominal lengths to ensure full, even, illumination. See pages 2 through 5 for additional details.
FS3
In-Line Fuse
Fixture Options
DE11,2
Lutron 1% Eco-System
1 See page 6 for details.
2 EM option not available in 4’ length.
Driver DIM1 0-10V 1% (Linear)
Sensor Options xE4,5 Enlighted xS14,5 Sensor Switch Daylight xS24,5 Sensor Switch Occ/Vac xS34,5 Sensor Switch Occ/Vac/ Daylight
4 �Minimum fixture length 2’.
See page 10 for full details.
5 Requires DIM driver (0-10V).
Replace “x” with quantity
347 Volt (consult factory) xSN nLight enabled (consult factory)
BL
Semi-Matte Black
EMR
Remote Micro Inverter (consult factory)
EM6,7,8
Integral EM Battery Pack xV Lutron Vive (consult factory)
3000K
80+ CRI
2700K
80+ CRI
3500K
80+ CRI
4000K
80+ CRI
DL011,2
eldoLED 0.1% SOLOdrive 0-10V (Logarithmic)
DED1,2
eldoLED 1% ECOdrive DALI-2 (Logarithmic)
D011,2 eldoLED 0.1% SOLOdrive 0-10V (Linear)
DIL1,2
eldoLED 1% ECOdrive 0-10V (Logarithmic)
RGBW
(consult factory)
* See page 11 for details.
1C45 80CRI-1018lm 90CRI-855lm 11.1W per foot
1C40 80CRI-954lm 90CRI-802lm 9.9W per foot
1C35 80CRI-834lm 90CRI-701lm 8.7W per foot
1C30 80CRI-746lm 90CRI-627lm 7.3W per foot
1C25 80CRI-594lm 90CRI-500lm 6.1W per foot
1C20 80CRI-494lm 90CRI-415lm 4.9W per foot
1C45 80CRI-1018lm 90CRI-855lm 11.1W per foot
1C40 80CRI-954lm 90CRI-802lm 9.9W per foot
1C35 80CRI-834lm 90CRI-701lm 8.7W per foot
1C30 80CRI-746lm 90CRI-627lm 7.3W per foot
1C25 80CRI-594lm 90CRI-500lm 6.1W per foot
1C20 80CRI-494lm 90CRI-415lm 4.9W per foot
BUY
AMERICAN
T9 Lit “T” section 90° Corner
X9 Lit “X” section 90° Corner
L9 Lit Horizontal 90° Corner
TC
Lit “T” section Custom Angle Corners (consult factory)
XC
Lit “X” section Custom Angle Corners (consult factory)
LC
Lit Horizontal Custom Angle Corners (consult factory)
SS3
Separate Switching
CS
Custom Switching (consult factory)
AH1
Luminaire Type
AA1
confirm with architect
(Rev. 10/2024) L60DI_SS_v4.3
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2024, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
4 3/4” (120mm)
2 1/4”(56mm)
2 3/8” (60mm)
Construction:
Housing - Continuous, low copper 6063-T6 extruded aluminum profile with aluminum endcaps, available as Individual fixtures (up to 12’) or Runs.
Geartray - Low copper 6063-T6 extruded aluminum profile.
Shielding - Extruded, impact resistant acrylic lens:
- LED Optimized White Lens (LW)
- Clear Lens with Microprism (MI)
- “LMO” Wide Batwing (WB) - Indirect Only
| (Recommended mounting distance from ceiling |
| to top of luminaire for WB lens is 24” or greater |
| for best optical performance). |
Direct only:
“LMO” refers to the Selux proprietary LED optical system - Light modulation optics. These lenses (other than WB) are offered in M60 behind a Satine Lens for even illumination and comfortable lit appearance.
- “LMO” Symmetric Lens (NB)
- “LMO” Asymmetric 20° Wall Washer (A2)
- “LMO” Asymmetric 5° Wall Grazer (A5)
- “LMO” Batwing (BW)
Mounting(s)- 1/16” Aircraft Cable, Ø5/8” Swivel or Rigid Steel Stem, Wall Bracket, (see pages 3 through 5 for details).
** Cable, Stem and Wall mountings may not be symmetrical for Runs and Configurations due to the use of modular housing lengths. If symmetrical suspensions are required please consult the factory.
** Mixed mountings are possible - consult factory.
Standard Luminaire lengths - All standard luminaires are supplied in nominal lengths to ensure full, even, illumination. Runs and Configurations are available in approximately 1’ increments starting at the nominal 12’ fixture length.
** Individual luminaires are not joinable in the field.
Exact length luminaires - Individual luminaires, Runs, and Configurations are available in exact lengths to meet your project needs. Please consult factory with you requirements.
** Lens luminance may soften at the very ends of the straight sections for exact length luminaires.
L60 Joiner(s) - Runs and Configurations are supplied in multiple housings that are joined together in the field using the supplied L60 Joining System. This allows ease of installation and ensures a uniform appearance (see page 9 for details).
Weight: 2.8 lb. per foot.
Electrical/Performance:
LED Light Engine - Brand-name mid-power LEDs create a high efficiency LED light engine able to provide a lumen maintenance of 95% at 25,000 hours and 90% at 60,000 hours at 25ºC per TM-21 reports. Reported L70 greater than 60,000 hours.
Photometrics - Consult website or factory for IES Files. Independent photometric lumen measurement complies with IES LM-79-08 testing procedures. Due to the LED manufacturer’s tolerances, the listed output has a ±5% tolerance.
For outputs based on different optics or CCT, please see page 12 for details.
CCT - Available in 2700K, 3000K, 3500K and 4000K, tolerance within a 3-step MacAdam ellipse.
CRl - 90+ and 80+ CRI.
All Drivers - High efficiency, constant current, soft start, Electronic Class 2 with a PFC>0.90. For more detailed information on the available drivers please see page 6.
Sensors - Selux offers a variety of integral sensor options. Sensors are placed on the direct side of the fixture, but can control the Indirect lighting. For details and specifications, please refer to page 10.
Emergency - There are multiple emergency options available - Emergency Circuit, Remote Micro Inverter, and EM Integral Battery Pack.
Please consult factory for use of sensors with emergency options. For more details on EC and EM options, see page 9.
Thermal Performance:
Ambient Operating Temperature - Luminaires suitable for maximum ambient temperature of 25°C (77°F) for DE1 at 1C40 and 1C45 light engines; 35°C (95°F) for all others.
Luminaires are suitable for minimum ambient temperatures of -40ºC (-40ºF) for DIM, DIL, DED, D01, and DL01 drivers; 0ºC (32ºF) for DE1 drivers.
Luminaire Finish:
Powder Coat - All Selux luminaires are finished in high quality polyester powder coating in our Tiger Drylac certified facility and are tested in accordance with test specifications for coatings from ASTM and PCI.
All products undergo a five stage intensive pretreatment process where product is thoroughly cleaned, phosphated, and sealed. Selux powder coated products provide excellent salt and humidity resistance as well as ultra violet resistance for color retention.
Standard interior colors are White (WH), Semi-Matte Black (BL), and Silver (SV). Selux premium colors (SP) are available, please specify from your Selux color selection guide.
Warranty:
5 Year Limited LED Luminaire Warranty - Selux offers a 5 Year Limited Warranty to the original purchaser that the M60 LED luminaire shall be free from defects in material and workmanship for up to five (5) years from date of shipment. This limited warranty covers the LED driver and LED light engine when installed according to Selux instructions and operated within the Ambient Temperature. For additional details and exclusions, see “Selux Terms and Condition of Sale.”
Certifications and Compliance:
NRTL - For Dry and Damp Locations (I.E. cULus; cCSAus) ADA Compliant ARRA Compliant RoHS Compliant
LW Direct LW Indirect
LW Direct LMO WB Indirect
4 3/4” (120mm)
2 3/8” (60mm)
M60 LED Direct/Indirect
For Indirect WB option, the geartray is painted White for highest efficiency. For other colors, please consult factory.
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2024, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
M60 LED Direct/Indirect
Cable Mounting (C)
Outlet box for feed only (by others)
L6DI Cable (C) Suspension Detail (Feed location(s) only)
L6DI Cable (C) Suspension Detail (Non-Feed location(s) only)
Cross bar with 1/4”-20 rod and ground screw
1/4” x 5” diameter canopy (White)
2x White cable stay
Cord strain relief bushing
1/4”-20 Threaded rod (supplied and installed in the field by others)
1. �Ø 1/16” Aircraft Cable with chrome gripper for easy adjustment (48” max. from ceiling to luminaire).
2x Outlet box screws (by others)
1/4”-20 Slip ring coupler
Feed cord (White)
1/16” Aircraft cable
1/4”-20 Slip ring coupler
1/16” Aircraft cable
Chrome gripper
Luminaire
1/4” x 2” diameter canopy (White)
Chrome gripper
Luminaire
Cable Mounting (C)
Min. 5/8” to Max. 3/4” m a x Cable Mounting (C) - Dimensions
Nominal Length
“A” Housing Length
* “B” (Ref.)
End Suspensions
“C” Mid. Suspension
“D” Feed Location
“E” Illuminated Length
Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM
02 (2ft.) 2' - 1/4" 616 0' - 7/8" 22 1' - 10 1/2" 572 0' - 3/8" 9 1' - 9" 534
03 (3ft.) 3' - 1/4" 921 0' - 7/8" 22 2' - 10 1/2” 876 0' - 3/8" 9 2' - 9" 839
04 (4ft.) 4' - 1/4" 1225 0' - 7/8" 22 3' - 10 1/2” 1181 0' - 3/8" 9 3' - 9" 1144
05 (5ft.) 5' - 1/4" 1530 0' - 7/8" 22 4' - 10 1/2” 1486 0' - 3/8" 9 4' - 9" 1448
06 (6ft.) 6' - 1/4" 1835 0' - 7/8" 22 5' - 10 1/2” 1791 0' - 3/8" 9 5' - 9" 1753
07 (7ft.) 7' - 1/4" 2140 0' - 7/8" 22 6' - 10 1/2” 2096 0' - 3/8" 9 6' - 9" 2058
08 (8ft.) 8' - 1/4" 2445 0' - 7/8" 22 7' - 10 1/2” 2400 0' - 3/8" 9 7' - 9" 2363
09 (9ft.) 9' - 1/4" 2749 0' - 7/8" 22 8' - 10 1/2” 2705 0' - 3/8" 9 8' - 9" 2668
10 (10ft.) 10' - 1/4" 3054 0' - 7/8" 22 9' - 10 1/2” 3010 0' - 3/8" 9 9' - 9" 2972
11 (11ft.) 11' - 1/4" 3359 0' - 7/8" 22 10' - 10 1/2” 3315 0' - 3/8" 9 10' - 9" 3277
12 (12ft.) 12' - 1/4" 3664 0' - 7/8" 22 11' - 10 1/2” 3620 0' - 3/8" 9 11' - 9" 3582
*Dimension(s) rounded to the nearest 1/16” with a ± 1/16” (1mm) tolerance.
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2024, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
M60 LED Direct/Indirect
Stem Mounting (S and RS)
Outlet box (supplied and installed by others)
L6DI Swivel Stem (S) Suspension Detail (feed wires through stem supplied by others)
L6DI Rigid Stem (RS) Suspension Detail (feed wires through stem supplied by others)
Hemispherical assembly
3/8” IP Crossbar with ground screws
1 7/16” x 5” diameter canopy (White)
1. �Ø 5/8” Swivel Stem provides 30° swivel and can be cut in field (48” max. from ceiling to luminaire).
2. �Ø 5/8” Rigid Stem is fixed and is not able to be cut/adjusted in field (48” max. from ceiling to luminaire).
Cotter pin
3/8” IP steel swivel stem (White)
Luminaire
Luminaire
Outlet box (supplied and installed by others)
3/8” IP nipple (supplied and installed by others)
Suspension hickey
1/4” x 5” diameter Canopy (White)
Canopy securing screw
Swivel Stem (S) and Rigid Stem (RS) Mounting
8” m a x
Dress nut
Square nut
Square nut
Square nut
Square nut
3/8” IP steel stem (White)
Dress nut
Swivel (S) & Rigid Stem (RS) Mountings - Dimensions
Nominal Length
“A” Housing Length
* “B” (Ref.)
End Suspensions
“C” Mid. Suspension
“D” Feed Location
“E” Illuminated Length
Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM
02 (2ft.) 2' - 1/4" 616 0' - 7/8" 22 1' - 10 1/2" 572 0' - 7/8" 22 1' - 9" 534
03 (3ft.) 3' - 1/4" 921 0' - 7/8" 22 2' - 10 1/2” 876 0' - 7/8" 22 2' - 9" 839
04 (4ft.) 4' - 1/4" 1225 0' - 7/8" 22 3' - 10 1/2” 1181 0' - 7/8" 22 3' - 9" 1144
05 (5ft.) 5' - 1/4" 1530 0' - 7/8" 22 4' - 10 1/2” 1486 0' - 7/8" 22 4' - 9" 1448
06 (6ft.) 6' - 1/4" 1835 0' - 7/8" 22 5' - 10 1/2” 1791 0' - 7/8" 22 5' - 9" 1753
07 (7ft.) 7' - 1/4" 2140 0' - 7/8" 22 6' - 10 1/2” 2096 0' - 7/8" 22 6' - 9" 2058
08 (8ft.) 8' - 1/4" 2445 0' - 7/8" 22 7' - 10 1/2” 2400 0' - 7/8" 22 7' - 9" 2363
09 (9ft.) 9' - 1/4" 2749 0' - 7/8" 22 8' - 10 1/2” 2705 0' - 7/8" 22 8' - 9" 2668
10 (10ft.) 10' - 1/4" 3054 0' - 7/8" 22 9' - 10 1/2” 3010 0' - 7/8" 22 9' - 9" 2972
11 (11ft.) 11' - 1/4" 3359 0' - 7/8" 22 10' - 10 1/2” 3315 0' - 7/8" 22 10' - 9" 3277
12 (12ft.) 12' - 1/4" 3664 0' - 7/8" 22 11' - 10 1/2” 3620 0' - 7/8" 22 11' - 9" 3582
*Dimension(s) rounded to the nearest 1/16” with a ± 1/16” (1mm) tolerance.
MODIFIED 4" canopy / j-box cover
0'-4"0'-8"
0'-3"
Power fed through 4" x 8" tube steel j-box above luminaire feeds and fans conduit from power pole feed at ends of cabinets
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2024, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
M60 LED Direct/Indirect
1. �Aluminum wall bracket (by Selux).
2. �4”x4” or 2”x4” J-Box at feed location (supplied and installed by others).
3. �1/4”-20 Threaded rod, 1/4”-20 lock washer and 1/4”-20 nut required to anchor the wall bracket. Mounting hardware supplied and installed to code by others.
Wall Mount (W) (Covers a 4x4 or 2x4 J-Box)
4” (102mm)
4” (102mm)
1”
(25mm)
3 3/8” (85mm)
Wall Mounting (W)
For patterns and configurations that include a wall mounted option, please see page 11 for details.
Wall (W) Mount - Dimensions
Nominal Length
“A” Housing Length
* “B” (Ref.)
End Suspensions
“C” Mid. Suspension
“D” Feed Location
Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM
02 (2ft.) 2' - 1/4" 616 0' - 6 1/8" 156 1' - 0" 305 0’ - 6 1/8” 156
03 (3ft.) 3' - 1/4" 921 0’ - 6 1/8” 156 2' - 0" 610 0’ - 6 1/8” 156
04 (4ft.) 4' - 1/4" 1225 0’ - 6 1/8” 156 3' - 0" 915 0’ - 6 1/8” 156
05 (5ft.) 5' - 1/4" 1530 0’ - 6 1/8” 156 4' - 0" 1220 0’ - 6 1/8” 156
06 (6ft.) 6' - 1/4" 1835 0’ - 6 1/8” 156 5' - 0" 1524 0’ - 6 1/8” 156
07 (7ft.) 7' - 1/4" 2140 0’ - 6 1/8” 156 6' - 0" 1829 0’ - 6 1/8” 156
08 (8ft.) 8' - 1/4" 2445 0’ - 6 1/8” 156 7' - 0" 2134 0’ - 6 1/8” 156
09 (9ft.) 9' - 1/4" 2749 0’ - 6 1/8” 156 8' - 0" 2439 0’ - 6 1/8” 156
10 (10ft.) 10' - 1/4" 3054 0’ - 6 1/8” 156 9' - 0" 2744 0’ - 6 1/8” 156
11 (11ft.) 11' - 1/4" 3359 0’ - 6 1/8” 156 10' - 0" 3048 0’ - 6 1/8” 156
12 (12ft.) 12' - 1/4" 3664 0’ - 6 1/8” 156 11' - 0" 3353 0’ - 6 1/8” 156
*Dimension(s) rounded to the nearest 1/16” with a ± 1/16” (1mm) tolerance.
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2024, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
M60 LED Direct/Indirect
Drivers:
*For inrush and control current, please refer to the driver manufacturers’ spec sheets.
Driver Quantity
Light Engine Dimming Code Length
2ft 3ft 4ft 5ft 6ft 7ft 8ft 9ft 10ft 11ft 12ft
1C20
DIM/DIL
1 2 4 2
D01/DL01/DED/DE1
1C25
DIM/DIL
1 2 4 2
D01/DL01/DED/DE1
1C30
DIM/DIL
1 2 4
D01/DL01/DED/DE1
1C35
DIM/DIL
1 2 4
D01/DL01/DED/DE1
1C40
DIM/DIL/DE1
1 2
4 6
D01/DL01/DED 2
1C45
DIM/DIL/DE1
1 2
1 4
4 6
D01/DL01/DED 2 4
0-10V linear dimming (DIM) Luminaires supplied with drivers offering the capability of either normal switched operation of 0-10V dimming for linear dimming curve. Fixtures ship wired for dimming. For on/off functionality, simply cap the dimming leads. Minimum dimming level preset at factory to 1%.
0-10V logarithmic eldoLED ECOdrive dimming (DIL) Luminaires supplied with drivers offering the capability of either normal switched operation of 0-10V dimming for logarithmic dimming curve, Fixtures shipped wired for dimming. For on/off functionality, simply cap the dimming leades. Minimum dimming level preset at factory to 1%.
eldoLED ECOdrive DALI-2 dimming (DED) Luminaires supplied with ECOdrive DALI-2 dimming driver with logarithmic dimming curve. Minimum dimming level preset at factory to 1%. For “dim to dark” (down to 0.1%), please consult factory.
eldoLED SOLOdrive 0-10V linear dimming (D01) Luminaires supplied with SOLOdrive 0-10V dimming driver with linear dimming curve. Minimum dimming level preset at factory to 0.1% and “dim to dark”.
eldoLED SOLOdrive 0-10V logarithmic dimming (DL01) Luminaires supplied with SOLOdrive 0-10V dimming driver with logarithmic dimming curve. Minimum dimming level preset at factory to 0.1% and “dim to dark”.
LUTRON EcoSystem dimming (DE1) Luminaires supplied with Hi-Lume EcoSystem (4 wire, digital link) dimming driver programmed for Constant Current Reduction (CCR). Minimum dimming level down to 1% with SoftOn/FadeToBlack.
* �For control recommendations, please contact driver manufacturer.
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2024, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
M60 LED Direct/Indirect
Wiring Diagrams
Sensor Wiring Diagrams
- The following wire(s) are in addition to the standard above -
DE1
0-10V linear (DIM) 0-10V logarithmic eldoLED ECOdrive (DIL) DALI logarithmic eldoLED ECOdrive (DED) 0-10V linear eldoLED SOLOdrive (D01) 0-10V logarithmic eldoLED SOLOdrive (DL01)
DIM, DIL, DED, D01, DL01
Lutron EcoSystem (DE1)
Lutron 2-Wire (DC2)
DC2
Standard Wiring supplied for all drivers
Green = Ground White = Neutral Black = Hot
Gray = (-) DALI or 0-10V Dimming Control Purple = (+) DALI or 0-10V Dimming Control
Violet = “E1” Digital Link Dimming Control Violet/White = “E2” Digital Link Dimming Control
No additional wires
Driver
Driver
Driver
Feed Green White Black
Grey (-) Purple(+)
Green White Black
Feed Green White Black Violet
Violet/White
Feed
Neutral
Hot 120/277V white white pink purple red black
Neutral Hot 120/277V
0-10V
AUX(+)
AUX(-)
Enlighted
Lutron Vive
Sensor Switch
Eldo 0-10V Driver black purple black red
E1(+) E2(-)
AC(+)
purple purple blue blue black white
AC OUT(+)
AC IN(+)
RJ45
0-10
Sensor
SU-5E-IL
Sensor Switch
MSD EZ7
Sensor
LED light Engine
DIM
Driver
Fixture Control Digital Interface
Lutron Vive
Control Unit
CU-4E-FM
Ecosystem Driver
S(+) S(-)
E1(+) E2(-)
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2024, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
M60 LED Direct/Indirect
Driver power chart - use below values to determine the nominal watts per foot based on driver, light engine, and voltage.
* Driver losses increase the wattage for fixtures less than 4 foot.
** Values are nominal values determined based on multiple tested fixtures.
Driver Power Usage
Driver Light Engine Nominal W/ft
120V 277V 347V
DIM, DIL, DED, D01,
DL01
1C20 4.9 5.3 n/a
1C25 6.1 6.5
1C30 7.3 7.7
1C35 8.7 8.9
1C40 9.9 10.1
1C45 11.1 11.3
DE1
1C20 5.5 5.2 n/a
1C25 6.7 6.3
1C30 8.0 7.6
1C35 9.3 8.8
1C40 10.5 10.0
1C45 11.7 11.2
DIM@347V
1C20 n/a n/a
5.4
1C25 6.5
1C30 7.7
1C35 8.8
1C40 10.0
1C45 11.2
EM all 6 n/a
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2024, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
M60 LED Direct/Indirect
Joiner System - standard for Runs and Configurations
Fuse (FS) - Fusing, luminaires supplied with a in-line fuse located on the hot wire for each feed (supplied with an 8A slow burn fuse).
Mixed Output - Luminaires have ability to offer mixed light engines (i.e. 1C35 direct and 1C25 indirect) starting at 4’.
Separate Switching (SS) - Luminaires available with separately switched 4’ (nominal) sections starting at 7’ and up. Luminaire is intended to be wired to the same panel/breaker (not intended for Emergency use).
Separate Switching between direct and indirect side is possible for all driver selections from 4’ and up. For Separate Switching of direct and indirect side for luminaires less than 4’, please consult factory.
*All separately switched (non-EM) circuits within an individual
| luminaire, linear run, or configuration must be connected to the |
| same branch circuit on-site. |
*To specify this option, the number of separately switched sections and locations of these sections must be provided at time of order.
*For Separate Switching with sensors, please consult factory.
Custom Switching (CS) - For project-specific switching requirements, please consult factory.
Emergency Wiring (EC) - EC luminaires are intended to be wired to separate panels/breakers for emergency use. See install instructions for proper wiring.
For 2’ to 6’ nominal luminaires, the entire fixture is wired for operation on emergency circuit.
For 7’ and up nominal luminaires, the first 4’ nominal length is wired for operation by a separate EM circuit by default to meet the required “Life Safety Code” (NFPA 101).
If a different configuration is needed, please consult factory.
Note: Wiring may vary slightly due to on-site conditions or local codes. Please follow all safety installation protocols contained within install instructions when installing luminaire.
Emergency Battery (EM) – The EM battery is located integral to fixture and is factory pre-wired. See install instructions for proper wiring.
10W constant power Emergency Battery Pack.
Direct fixtures are available for emergency battery (EM) use in 4’ and ≥6.
Due to size constraints, EM is not available in 5’ fixtures.
For individual fixtures, emergency option will illuminate the first 4’ section of fixture. For continuous runs, please consult factory to advise on 4’ section intended for emergency use. For fixtures >12’ or if a different configuration is needed, please consult factory.
Emergency test switch is located next to the geartray, behind the lens.
| * | Emergency battery option is UNV for use with 120V or 277V and is not |
| available for 347V. |
* Please note battery pack requires an unswitched hot.
* For EM with sensors, please consult factory.
* If a different configuration is needed, please consult factory.
Note: Wiring may vary slightly due to on-site conditions or local codes.
Please follow all safety installation protocols contained within install instructions when installing luminaire.
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2024, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
M60 LED Direct/Indirect
Lens
Fixture Length
Lit Section* 3” (76mm)
Qty 1 Sensor - Beginning
2 3/8” (60mm)
Qty 3+ Sensor - For spacing between sensors, please consult the sensor manufacturer.
Beginning of Run
Aluminum Sensor Plate -to be painted same as fixture unless specified otherwise
Qty 2 Sensor - Beginning and End (9’ fixtures and longer)
Notes: 1. For spacing between sensors, please consult the sensor manufacturer.
2. Exact sensor placement and coverage will be defined by approved factory drawing.
3. Sections controlled by sensors may not be symmetrical - consult factory for layout.
*�Lit section will be the fixture length minus 3” for sensor plate.
Factory Presets - �Sensors come from the sensor manufacturer with factory presets for each of the settings in above chart. Please see sensor manufacturers’ spec sheets for details on presets and re-programming.
Commissioning - �Commissioning of sensors and installation by others. Contact sensor manufacturer for details and costs associated with commissioning the system prior to specification of sensors.
Standard Sensor Placement - for other placement options, please consult factory. For functionality and limitations, please see sensor details above.
Occupancy Vacancy Daylight Harvesting Driver Compatibility
Enlighted SU-5E-IL (E) √ √ √ DIM
Sensor Switch MSD EZ (S) √ √ √ DIM
Lutron Vive DFCSJ (V) √ √ √ DE1
Sensor Ordering Chart
Quantity Sensor Settings* x Number of Sensors E Enlighted SU-5E-IL
S Sensor Switch MSD EZ
V Lutron Vive DFCSJ
1 Daylight
2 Occupancy/Vacancy
3 Daylight/Occupancy/Vacancy
* Settings not available with Enlighted
Enlighted SU-5E-IL (E) Enlighted Micro Sensor SU-5E-IL (Independent Lighting) provided as standard with an Enlighted CU-4E-FM Fixture Mount Control Unit integral to fixture. If SU-5E-CL (Connected Lighting) or SU-5E-IoT (Internet of Things) is desired, please contact factory. Occupancy/vacancy, thermal, daylight sensing plus Tunable White, Room & Zone control, Internet of Things (IoT) data collection and reporting control. For full details, please see SU-5E-(IoT/ CL/IL) spec sheet on the Enlighted website. Must be paired with a 0-10V driver with auxiliary (DIM driver selection). Commissioning by Enlighted.
*Sensor can control up to 5 drivers. Please refer to driver quantity chart on page 6. Multiple sensors may be required for longer lengths.
Sensor Switch MSD EZ (S) Occupancy/vacancy and daylight harvesting. For full functionality and programming options, select settings option 3. If a different settings option is selected, other settings may be unavailable. For full details, please see MSD EZ spec sheets on the Sensor Switch website. Must be paired with DIM driver selection. Manual control of dimming not available with MSD EZ sensor.
*Sensor can control up to 30 drivers. Please refer to driver quantity chart on page 6. Multiple sensors may be required for longer lengths.
Lutron Vive DFCSJ (V) The DFCSJ-OEM-OCC provides the capabilities of daylight harvesting and occupancy/vacancy sensing. When integrated with the DFC-OEM-DBI (Fixture Contril Digital Link Interface), the sensor is wirelessly compatible with the DE1 Lutron EcoSystem driver. Commissioning bt certified Lutron technician.
*Vive DFCSJ sensor can control up to a maximum of five (5) drivers per sensor. Please refer to driver chart on page 6. Multiple sensors may be required for longer lengths.
Please contact controls manufacturer for details prior to specifying.
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2024, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
Listed below are the minimum lengths and details for standard shapes. These standard shapes can be combined with each other and/or the standard luminaire lengths, ensuring full even illumination. If you have any questions, please consult the factory.
The minimum standard lengths for “L” shapes:
- L9 open shapes is 4’ x 4’ nominal (example: leg, 90, leg)
- L9 closed shapes is 6’ x 6’ nominal (example: 90, leg, 90) (�Exception is that the L9 can be joined directly to provide a 4’ x 4’ nominal shape)
*For sensors in configurations, please consult factory.
M60 LED Direct/Indirect
Standard Direct/Indirect shapes/configurations (L9, T9, X9):
The minimum standard lengths for “T” and “X” shapes:
- T9 = 4’ nominal on the short leg and 8’ nominal on the long side
- X9 = 8’ nominal for either direction
For patterns and configurations that include a wall-mounted option, please consult factory to identify location, on which side of housing and spacing of brackets required.
Selux is capable of supplying a wide range of project solutions including different shapes, angles, and sizes to meet the project requirements.
Due to the complex nature of these project specific layout(s) we ask that you please consult the factory with the project requirements for review.
Project Specific Direct/Indirect shapes/configurations (LC, TC, XC):
Note: The indirect side of the cable and stem mounted con�gurations has small unlit sections for suspensions. For wall mounted con�gurations, the indirect side is fully lit.
Direct side Bottom view
See note See note See note
Indirect side Top view
Indirect side Top view
Indirect side Top view
Direct side Bottom view
Direct side Bottom view
L9 - Lit Horizontal Corner T9 - Lit “T” Section X9 - Lit “X” Section
In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Specification sheets found at www.selux.us are the most recent versions and supercede all other printed or electronic versions.
Selux Corporation © 2024, T 845-834-1400, 800-735-8927, F 845-834-1401, www.selux.us
M60 LED Direct/Indirect
Photometry
Note: Due to the amount of variation of lens/ distribution options possible, please import and align the individual direct and indirect IES files and group within the photometric program you are using.
CCT and CRI multipliers apply to the photometry, IES files, and per foot values listed on page 1 (light engine).
Lens multipliers supplied for per foot values listed on page 1 (light engine).
LW - LED Optimized White Lens
Light Engine Lumens per 4 foot Lumens per foot Input watts per foot lm/W
1C35 2804 701 8.9 79
MI - Clear Lens with Microprism Inlay
Light Engine Lumens per 4 foot Lumens per foot Input watts per foot lm/W
1C35 3251 813 8.9 92
NB - LMO Symmetric (Direct Only)
Light Engine Lumens per 4 foot Lumens per foot Input watts per foot lm/W
1C35 3002 751 8.9 85
A2 - LMO Asymmetric 20° Wall Washer (Direct Only)
Light Engine Lumens per 4 foot Lumens per foot Input watts per foot lm/W
1C35 3032 758 8.9 86
A5 - LMO Asymmetric 5° Wall Grazer (Direct Only)
Light Engine Lumens per 4 foot Lumens per foot Input watts per foot lm/W
1C35 2807 702 8.9 79
WB - LMO Wide Batwing (Indirect Only)
Light Engine Lumens per 4 foot Lumens per foot Input watts per foot lm/W
1C35 3926 982 8.9 111
M60 Direct/Indirect
CCT Multiplier
4000K 1.05
3500K 1.00
3000K 0.96
2700K 0.92
CRI Multiplier
90+ CRI 1.00
80+ CRI 1.19
Lens Multiplier
LW 1.00
MI 1.02
NB 1.22
A2 1.26
A5 1.26
BW 1.0
WB 1.40
BW - LMO Batwing (Direct Only)
Light Engine Lumens per 4 foot Lumens per foot Input watts per foot lm/W
1C35 2807 702 8.9 79
SUPER HIGH EFFICACY LED STRIP
24V DC LED STRIP
DL-FLEX2-SHE
NY CA15 Harbor Park Drive
Port Washington, NY 11050
© 2024 JESCO LIGHTING GROUP, LLC
OF
Specifications subject to change without notice REV. 02/28/2024
800 527 7796 855 265 5768
800 527 7796 855 265 5768 support@jescolighting.com Tech Support 855 592 0029
219 South 6th Ave City of Industry, CA 91746
Main Fax
Main Fax
Project
Fixture Type
Notes
2700K
3000K
3500K
4000K
5000K
591 lm/ft
600 lm/ft
628 lm/ft
692 lm/ft
710 lm/ft
4.3 W/ft
4.3 W/ft
4.3 W/ft
4.3 W/ft
4.3 W/ft
137 lm/W
140 lm/W
146 lm/W
161 lm/W
165 lm/W
90+
90+
90+
90+
90+
PERFORMANCE
ORDERING INFO
COLOR TEMPERATURE
ORDERED BY THE FOOT
LUMEN WATTAGE EFFICACY CRI
2700K 3000K
Warm White
Neutral White
Cool White
3500K 4000K 5000K 2700K 3000K
Warm White
Neutral White
Cool White
3500K 4000K 5000K
JESCO Lighting's DL-FLEX2-SHE offers a market-leading efficacy of up to 165lm/W at 90CRI. The LED strip is field-cuttable every 2" and is made of highly flexible material that can be applied to most surfaces categorized as having high surface energy using 3M® double sided tape. An LED density of 54LEDs/ft ensure a diffused light output. The tape is dimmable using JESCO's various dimming options.
3-Step MacAdam LED binning for uniformity in both color and intensity Easy installation with 3M ® adhesive tape and a large variety of channel options available. 4 oz. copper PCB ensures optimal heat dissipation. No ultraviolet (UV/IR) radiation, and no mercury.
Low profile and flexible with Plug and Play and Hardwire options available.
SERIES MODEL
DL-FLEX2
COLOR
2790 - 2700K / 90CRI
3090 - 3000K / 90CRI
3590 - 3500K / 90CRI
4090 - 4000K / 90CRI
5090 - 3500K / 90CRI
– –SHE
ORDERED BY THE REEL
SERIES MODEL
DL-FLEX2
COLOR
2790 - 2700K / 90CRI
3090 - 3000K / 90CRI
3590 - 3500K / 90CRI
4090 - 4000K / 90CRI
5090 - 3500K / 90CRI
– –SHE
REEL LENGTH
– 20FT
• Specify required amount of 1 FT lengths before the ordering number.
Example: 10 x DL-FLEX2-SHE-4090
| • | DL-FLEX2-SHE is packed in 20’ reel lengths. |
| • | Each reel comes with an input Hardwire power connector pre-assembled |
to one end of the reel.
Example: DL-FLEX2-SHE-4090-20FT
IR
I550
IR
I550
IR
I550
IR
I550
+ 24 VDC+ 24 VDC + 24 VDC+ 24 VDC
7/ 16"
2"
QUICK SHIP
QUICK SHIP
QUICK SHIP
QUICK SHIP
QUICK SHIP
INPUT VOLTAGE
WATTAGE
LUMENS
LEDs/Ft.
CRI
DIMMING SIGNAL
DIMMING INPUT²
MIN RUN / MAX RUN¹
BEAM ANGLE
DIMENSIONS
AMBIENT TEMPERATURE³
COLOR CONSISTENCY
ENVIRONMENT
CERTIFICATIONS
WARRANTY4
24V DC
4.3 W/ft
See Performance Chart below
54 LEDs/ft
90+
PWM
0-10V / MLV/ ELV / TRIAC / C•L
RF & Wifi Smart Control, see page 14
READY, see page 15
2" / 20'
120º
7/16" W x 1/8" H
-14° to 113°F (-10° to 45°C)
-4° to 122°F (-20° to 50°C)
3 Steps MacAdam - Single Bin LEDs
Indoor - Dry cULus Listed, California Title 24 JA8 Compliant
5 Years
SPECIFICATIONS
24V DC 120 º BEAM DIMMABLE
INDOORHi - LumeIP65 ELV
REVERSE PHASE 0 -10V / 1 -10V
TRIAC
FORWARD PHASEIP66
0 -10V
RECEIVER
RF
INDOOR
OUTDOOR
WET
FIELD CUTTABLE 1BIN3SDCMMAX RUN
20 FT
MIN RUN
2 IN
| 4 | Low Voltage LED Flexible Linear shall have a limited warranty of |
| up to five (5) years from the original date of shipment. All LED | |
| Flexible Linear products will be deemed defective if there is a | |
| failure of 10% or more of the LED components. Where a replace | |
| ment is warranted, custom cut-to-order LED Flexible Linear will | |
| only be replaced as originally ordered. | |
| See published warranty terms for detailed information. |
| ¹ | � Must be paired with compatible JESCO dimmable driver or controller. |
| 2 | Single runs can not exceed max run length. Cuts can only be made on the cutting mark. |
| 3 | Exceeding the ambient or operating temperature values may damage the LEDs by reducing |
| the lifespan, lumen output, and/or adversely impact color consistency. It is recommended | |
| adequate airflow be taken into consideration in the installation and application of this product. | |
| Improper thermal management may lead to premature product failure and void the warranty. |
AH1
Luminaire Type
AB1
https://www.jescolighting.com/wp-content/installation/DL-FLEX2-SHE_Install.pdf https://www.jescolighting.com/wp-content/photometrics/dl-flex/dl-flex2-she/DL-FLEX2-SHE-2790.zip https://www.jescolighting.com/wp-content/photometrics/dl-flex/dl-flex2-she/DL-FLEX2-SHE-3090.zip https://www.jescolighting.com/wp-content/photometrics/dl-flex/dl-flex2-she/DL-FLEX2-SHE-3590.zip https://www.jescolighting.com/wp-content/photometrics/dl-flex/dl-flex2-she/DL-FLEX2-SHE-4090.zip https://www.jescolighting.com/wp-content/photometrics/dl-flex/dl-flex2-she/DL-FLEX2-SHE-5090.zip
© 2024 JESCO LIGHTING GROUP, LLC
OF
Specifications subject to change without notice REV. 02/28/2024
800 527 7796 855 265 5768
800 527 7796 855 265 5768 support@jescolighting.com Tech Support 855 592 0029
219 South 6th Ave City of Industry, CA 91746
Main Fax
Main Fax
Project
Fixture Type
Notes
PART NUMBER
DESCRIPTION
MAX. CURRENT
OPERATNG TEMP.
ENVIRONMENT
DIMENSIONS
DL-FLEX2-CRYSCONN10-PC40
12" plug and play power cord
5A¹
14°F to 113°F
Indoor, Dry
A 1/2" (12 mm) B 5/8" (16 mm) C 3/16" (4 mm) D 40" (1016 mm) E 13/8" (35 mm) F 1/2" (12 mm)
PART NUMBER
DESCRIPTION
MAX. CURRENT
OPERATNG TEMP.
ENVIRONMENT
DIMENSIONS
DL-FLEX2-CRYSCONN10-PC{40/79}-HW
12" Hardwire power cord
5A¹
14°F to 113°F
Indoor, Dry
A 1/2" (12 mm) B 5/8" (16 mm) C 3/16" (4 mm) D1 40" (1016 mm) D2 79" (2007 mm) E 1/2" (12 mm)
F 3/16" (5mm)
PART NUMBER
DESCRIPTION
MAX. CURRENT
OPERATNG TEMP.
ENVIRONMENT
DIMENSIONS
DL-FLEX2-CRYSCONN10-CC06
Connecting cable. Connects strip to strip
5A¹
14°F to 113°F
Indoor, Dry
A 1/2" (12 mm) B 5/8" (16 mm) C 3/16" (4 mm) D 6" (152 mm)
PART NUMBER
DESCRIPTION
MAX. CURRENT
OPERATNG TEMP.
ENVIRONMENT
DIMENSIONS
DL-FLEX2-CRYSCONN10-TT
Tape-to-Tape Connector
5A¹
14°F to 113°F
Indoor, Dry
A 1/2" (12 mm) B 5/8" (16 mm) C 3/16" (4 mm)
B
C height
D E
FA
B
C height
D1 40 / D2 79 E
FA
B
C height
D B
A
C height
A
B
C height
A
B
C height
D E
FA
B
C height
D1 40 / D2 79 E
FA
B
C height
D B
A
C height
A
B
C height
A
B
C height
A
B
C height
D E
FA
B
C height
D1 40 / D2 79 E
FA
B
C height
D B
A
C height
A
B
C height
A
B
C height
D E
FA
B
C height
D1 40 / D2 79 E
FA
B
C height
D B
A
C height
A
B
C height
A
B
C height
A
B
C height
D E
FA
B
C height
D1 40 / D2 79 E
FA
B
C height
D B
A
C height
A
B
C height
A
B
C height
D E
FA
B
C height
D1 40 / D2 79 E
FA
B
C height
D B
A
C height
A
B
C height
A
B
C height
A
B
C height
D E
FA
B
C height
D1 40 / D2 79 E
FA
B
C height
D B
A
C height
A
B
C height
A
B
C height
D E
FA
B
C height
D1 40 / D2 79 E
FA
B
C height
D B
A
C height
A
B
C height
A
C height
A
NOTE: Avoid cutting on soldered joints. Segments with solder joint will not work with connector.
All dimensions are nominal
CRYSTAL Connectors
WIRING ACCESSORIES
IR
I550
IR
I550
IR
I550
IR
I550
+ 24 VDC+ 24 VDC + 24 VDC+ 24 VDC
IR
I550
IR
I550
IR
I550
+ 24 VDC+ 24 VDC+ 24 VDC
IR20
I550
IR20
I550
IR20
I550
IR20
I550
+24 VDC
+24 VDC
+24 VDC
+24 VDC
IR
I550
IR
I550
IR
I550
IR
I550
+ 24 VDC+ 24 VDC + 24 VDC+ 24 VDC
IR
I550
IR
I550
IR
I550
+ 24 VDC+ 24 VDC+ 24 VDC
IR20
I550
IR20
I550
+24 VDC
+24 VDC
IR
I550
IR
I550
IR
I550
IR
I550
+ 24 VDC+ 24 VDC + 24 VDC+ 24 VDC
IR
I550
IR
I550
+ 24 VDC+ 24 VDC+ 24 VDC24VDC+
BLACK [ - ]
RED[ + ]
BROWN LIVE
BLUE NEUTRAL
TYPICAL DIRECT WIRING
TRIAC / ELV
Forward Phase
TYPICAL TRIAC/ELV DIMMING WIRING
NOTE: wiring must be done following local and NEC codes
TYPICAL DIRECT WIRING
RED [ + ]
PURPLE [ - ]
BLACK OR WHITE [ - ]
BLACK LIVE
WHITE NEUTRAL
RED [ + ]
PURPLE [ - ]
BLACK OR WHITE [ - ]
BLACK LIVE
WHITE NEUTRAL
DIMMER OUTPUT LIVE
BLACK LIVE
DIMMER NEUTRAL
DL-PS-[30/40/96]/24-JB-OD-S
DL-PS-[40/60/96]/24-JB-DIM-A
DL-PS-[40/60/96]/24-JB-DIM-A
IR
I550
IR
I550
IR
+ 24 VDC+ 24 VDC+ 24 VDC
2 4
24V DC
2 4
24V DC
TYPICAL PRIMARY DIMMING
TYPICAL SECONDARY DIMMING
DIMMING
CONTROLLER
W
IR
IN
G
SC
H
EM
A
TI
C
1 CLASS 2 limits to 4A 96W for 24V DC system
HOW TO INSTALL PLUG-&-PLAY
AND HARDWIRE CRYSTAL
POWER CONNECTORS FLEX TAPE
HOW TO INSTALL TAPE-TO-TAPE
CRYSTAL CONNECTORS
TO FLEX TAPE
https://youtu.be/n0AB3qeJMew https://youtu.be/PnqDwgJ1OMM
© 2024 JESCO LIGHTING GROUP, LLC
OF
Specifications subject to change without notice REV. 02/28/2024
800 527 7796 855 265 5768
800 527 7796 855 265 5768 support@jescolighting.com Tech Support 855 592 0029
219 South 6th Ave City of Industry, CA 91746
Main Fax
Main Fax
Project
Fixture Type
Notes
IR
I550
IR
I550
IR
I550
IR
I550
+ 24 VDC+ 24 VDC + 24 VDC+ 24 VDC
IR
I550
IR
I550
IR
I550
+ 24 VDC+ 24 VDC+ 24 VDC
IR20
I550
IR20
I550
+24 VDC
+24 VDC
IR
I550
IR
I550
IR
I550
IR
I550
+ 24 VDC+ 24 VDC + 24 VDC+ 24 VDC
A
B
C height
D E
F
A
B
C height
C height C height
D E
F
A A
B BD1 D2 D3
A
B
C height
A
B
C height
2 5
PART NUMBER DL-FLEX2-CLAMP-PC-10B
DESCRIPTION 12” Plug & Play power cord
MAX. CURRENT 5A1
OPERATNG TEMP. 14°F to 113°F
ENVIRONMENT Indoor, Dry
DIMENSIONS A 5/8" (14.6 mm) B 1" (24.5 mm) C 3/8" (8mm) D 12" (305mm) E 1 3/8" (35 mm) F 1/2" (12mm)
B
C height
D E
FA
B
C height
D1 40 / D2 79 E
FA
D1
CC3 CC6 CC12
D2 D3
C1 48 / C2 96
B
C height
D B
A
C height
A
B
C height
A
B
C height
D E
FA
B
C height
D1 40 / D2 79 E
FA
B
C height
D B
A
C height
A
B
C height
A
B
C height
A
B
C height
D E
FA
B
C height
D1 40 / D2 79 E
F A
B
C height
B
A
C height
A
B
C height
A
B
C height
A
B
C height
E
FA
C DB E
F
A
PART NUMBER DL-FLEX2-CLAMP-PC-HW-10B
DESCRIPTION 12” Harrdwire power cord
MAX. CURRENT 5A1
OPERATNG TEMP. 14°F to 113°F
ENVIRONMENT Indoor, Dry
DIMENSIONS A 5/8" (14.6 mm) B 1" (24.5 mm) C 3/8" (8mm) D 12" (305mm) E 1/2" (12 mm) F 3/16" (5mm)
B
C height
D E
FA
B
C height
D1 40 / D2 79 E
FA
D1
CC3 CC6 CC12
D2 D3
C1 48 / C2 96
B
C height
D B
A
C height
A
B
C height
A
B
C height
D E
FA
B
C height
D1 40 / D2 79 E
FA
B
C height
D B
A
C height
A
B
C height
A
B
C height
A
B
C height
D E
FA
B
C height
D1 40 / D2 79 E
F A
B
C height
B
A
C height
A
B
C height
A
B
C height
A
B
C height
E
FA
C DB E
F
A
F
PART NUMBER DL-FLEX2-CLAMP-CC 3/6/12 -10B
DESCRIPTION Connecting cable. Connects strip to strip
MAX. CURRENT 5A¹
OPERATNG TEMP. 14°F to 113°F
ENVIRONMENT Indoor, Dry
DIMENSIONS A 5/8" (14.6mm) B 1" (24.5mm) C 3/8" (8mm) D1 3" (76mm) D2 6" (152mm) D3 12" (305mm)
B
C height
D E
FA
B
C height
D1 40 / D2 79 E
FA
D1
CC3 CC6 CC12
D2 D3
C1 48 / C2 96
B
C height
D B
A
C height
A
B
C height
A
B
C height
D E
FA
B
C height
D1 40 / D2 79 E
FA
B
C height
D B
A
C height
A
B
C height
A
B
C height
A
B
C height
D E
FA
B
C height
D1 40 / D2 79 E
F A
B
C height
B
A
C height
A
B
C height
A
B
C height
A
B
C height
E
FA
C DB E
F
A
F
PART NUMBER DL-FLEX2-CLAMP-WT10B
DESCRIPTION Wire to tape clamp connector
OPERATNG TEMP. 14°F to 113°F
ENVIRONMENT Indoor, Dry
DIMENSIONS A 5/8" (14.6mm) B 1" (24.5mm) C 3/8" (8mm)
B
C height
D E
FA
B
C height
D1 40 / D2 79 E
FA
D1
CC3 CC6 CC12
D2 D3
C1 48 / C2 96
B
C height
D B
A
C height
A
B
C height
A
B
C height
D E
FA
B
C height
D1 40 / D2 79 E
FA
B
C height
D B
A
C height
A
B
C height
A
B
C height
A
B
C height
D E
FA
B
C height
D1 40 / D2 79 E
F A
B
C height
B
A
C height
A
B
C height
A
B
C height
A
B
C height
E
FA
C DB E
F
A
F
A
1 CLASS 2 limits to 4A 96W for 24V DC system
PART NUMBER DL-FLEX2-CLAMP-TT10B
DESCRIPTION Tape to tape clamp connector
OPERATNG TEMP. 14°F to 113°F
ENVIRONMENT Indoor, Dry
DIMENSIONS A 5/8" (14.6mm) B 7/8" (19.5mm) C 3/8" (8mm)
NOTE: Avoid cutting on soldered joints. Segments with solder joint will not work with connector.
All dimensions are nominal
B
C height
D E
FA
B
C height
D1 40 / D2 79 E
FA
D1
CC3 CC6 CC12
D2 D3
C1 48 / C2 96
B
C height
D B
A
C height
A
B
C height
A
B
C height
D E
FA
B
C height
D1 40 / D2 79 E
FA
B
C height
D B
A
C height
A
B
C height
A
B
C height
A
B
C height
D E
FA
B
C height
D1 40 / D2 79 E
F A
B
C height
B
A
C height
A
B
C height
A
B
C height
A
B
C height
E
FA
C DB E
F
A
F
A
Clamp Connectors
WIRING ACCESSORIES
W
IR
IN
G
SC
H
EM
A
TI
C
© 2024 JESCO LIGHTING GROUP, LLC
OF
Specifications subject to change without notice REV. 02/28/2024
800 527 7796 855 265 5768
800 527 7796 855 265 5768 support@jescolighting.com Tech Support 855 592 0029
219 South 6th Ave City of Industry, CA 91746
Main Fax
Main Fax
Project
Fixture Type
Notes
B CD1
48 96
D2
B CD
A
A
A
A
C
A
A
B
B
C D
C D
D input cable
E output cable
SWITCH/SENSOR
IN
PU
T O
U
TP
U T
24V LIGHT FIXTURE
24V LIGHT FIXTURE
3 4 5
B CD1
48 96
D2
B CD
A
A
A
A
C
A
A
B
B
C D
C D
D input cable
E output cable
SWITCH/SENSOR
IN
PU
T O
U
TP
U T
3 4 5
B CD1
48 96
D2
B CD
A
A
A
A
C
A
A
B
B
C D
C D
D input cable
E output cable
SWITCH/SENSOR
IN
PU
T O
U
TP
U T
3 4 5
A
C D
A
B
C D
IN
PU
T O
U
TP
U T
A
C
B D input cable
E output cable
PART NUMBER
DESCRIPTION
MAX. CURRENT
ENVIRONMENT
DIMENSIONS
DL-PS-EXT48, DL-PS-EXT48-WH or
DL-PS-EXT96, DL-PS-EXT96-WH,
48" / 96" Extension Cable. Black Finish is the standard. Specify White Finish with -WH.
4A
Indoor, Dry
A 1/2" (11.8 mm) B 15/8" (41 mm) C 13/4" (43 mm)
D1 48" (1220 mm) D2 96" (2440 mm)
WIRING ACCESSORIES
W
IR
IN
G
SC
H
EM
A
TI
C
PART NUMBER
DESCRIPTION
MAX. CURRENT
ENVIRONMENT
DIMENSIONS
DL-PS-2Y or DL-PS-3Y
2Y / 3Y Splitter
4A
Indoor, Dry
A 1/2" (11.8mm) B 15/8" (41 mm) C 13/4" (43 mm)
D 11/2" (38 mm)2
PART NUMBER
DESCRIPTION
MAX. CURRENT
ENVIRONMENT
DIMENSIONS
DL-PS-SW-PIR-BK
In-line Passive Infrared Sensor Switch
Input & Output Cables Included
4A
Indoor, Dry (use #4 screws for mounting)
A 13/4" (44 mm) B 15/8" (41 mm) C 3/4" (19 mm)
D 40 3/8" (1025 mm) E 40 1/2" (1028 mm)
IN-LINE SWITCH/SENSOR
PART NUMBER
DESCRIPTION
MAX. CURRENT
ENVIRONMENT
DIMENSIONS
PART NUMBER
DESCRIPTION
MAX. CURRENT
ENVIRONMENT
DIMENSIONS
DL-PS-SW-PIR-DOOR
In-line Passive Infrared Sensor Switch
Input & Output Cables Included
4A
Indoor, Dry (mount via 3M VHB tape included)
A 1 1/8" (29 mm) B 3/8" (9.5 mm)
C 13/4" (45 mm) D 7" (178 mm)
DL-PS-SW-WH
In-line Capacitive Touch Switch with Dimming
4A
Indoor, Dry (Recessed installation in 3/4" hole)
A 7/8" (22mm) C 5/8" (16 mm) D 7" (200 mm)
NOTE: All dimensions are nominal with +/- 1" tolerance.
4A current max, 96W max @24V DC https://www.jescolighting.com/wp-content/specsheets/DL-PS-SW-PIR-BK_Specs.pdf https://www.jescolighting.com/wp-content/specsheets/DL-PS-SW-PIR-DOOR_Specs.pdf https://www.jescolighting.com/wp-content/specsheets/DL-PS-SW-WH_Specs.pdf
© 2024 JESCO LIGHTING GROUP, LLC
OF
Specifications subject to change without notice REV. 02/28/2024
800 527 7796 855 265 5768
800 527 7796 855 265 5768 support@jescolighting.com Tech Support 855 592 0029
219 South 6th Ave City of Industry, CA 91746
Main Fax
Main Fax
Project
Fixture Type
Notes
CH-SM-31 CH-SM-33 CH-SM-21 CH-SM-26 CH-SM-25CH-ME-31
FR
CH-RI-18
CH-RM-31 CH-RM-32 CH-RM-33 CH-RM-34 CH-RM-35
CH-RI-17 CH-SM-36 CH-SM-35 CH-SM-24
CL FR FR60OP FR OP OPCL CL15 CL30 CL60FR FR60OP
W
CL FR FR60OP
H2 H1
IW
CH-SM31
CH-ME-32 CH-SM-32 CH-SM-33 CH-SM-22 CH-RI-19
W
OP
H
IW
1.00” 25mm 1.10” 28mm 0.87” 22mm
W
OP
H
IW
1.35” 35mm 1.35” 35mm 0.94” 24mm
W
OP
H
IW
0.39” 10mm 0.39” 10mm 0.24” 24mm
W
AROP ARFR TROP
H
IW
0.39” 10mm 0.39” 10mm 0.24” 24mm
W
OP
H
IW
0.72” 18mm 0.72” 18mm 0.55” 14mm
W
CL FR OP
H
IW
0.72” 18mm 0.72” 18mm 0.55” 14mm
W H
IW
W H
IW
W H
IW
W H
IW
W
H2 H1
IW
W
H2 H1
IW
0.31” 8mm 0.47” 12mm 0.22” 6mm
FR
W H
IW
0.50” 13mm 0.47” 12mm 0.22” 6mm
OP OP
W H
IW
2.23” 53mm 0.55” 14mm 0.41” 11mm
W H
IW
2.42” 62mm 0.55” 14mm 0.81” 21mm
OP
W H
IW
3.44” 88mm 0.73” 19mm 1.46” 37mm
OP
W H
IW
0.68” 17mm 3.78” 96mm 0.67” 17mm
OP
W H
IW
0.68” 17mm 5.27” 134mm 0.67” 17mm
OP
W H
IW
0.87” 22mm 0.51” 13mm 0.48” 12mm
OP
W H
IW
1.97” 50mm 1.35” 35mm 0.94” 24mm
OP
W H
IW
0.84” 21mm 1.03” 26mm 0.48” 12mm
CL FR OP
W H
IW
0.91” 23mm 0.31” 8mm 0.48” 12mm
CL FR OP
W H
IW
0.91” 23mm 0.60” 15mm 0.48” 12mm
FR OP
W H
IW
1.20” 31mm 0.40” 10mm 0.79” 20mm
0.93” 24mm 0.43” 11mm 0.79” 20mm
0.93” 24mm 0.43” 11mm 0.79” 20mm
0.67” 17mm 0.79” 20mm 0.40” 10mm
0.67” 17mm
0.53” 13mm 0.34” 9mm
0.48” 12mm
0.67” 17mm
0.88” 22mm 0.60” 15mm
0.48” 12mm
CL CL15 FR FR60 OP AROP SOP
Clear Frosted
Beam angle
Opal
Beam angle Shape Shape
CH-SM-37
CH-FL-32
CH-FL-31
Does not fitFit Fit 2 strips
Full di�usion
KEYS
Limited di�usion Does not apply
Min LED/Ft to achieve full di�usion
Compatibility
Di�usion
Available lens options
Model No.
Width
Height
Inner Width
H1 H2
60° 15° 30° 60°
INDIRECTINDIRECT
60°
H2 H1
60°
H2 H1
0.67” 17mm
0.53” 13mm 0.34” 9mm
0.48” 12mm
W
H1
IW
18 36 5472
72 72 72
72 72
72 72 72
72 100
18 18
18 18
36 36 36
H H
© 2024 JESCO LIGHTING GROUP, LLC
OF
Specifications subject to change without notice REV. 02/28/2024
800 527 7796 855 265 5768
800 527 7796 855 265 5768 support@jescolighting.com Tech Support 855 592 0029
219 South 6th Ave City of Industry, CA 91746
Main Fax
Main Fax
Project
Fixture Type
Notes
IR
I550
IR
I550
IR
+ 24 VDC+ 24 VDC+ 24 VDC
DL-PS-[WP24/24/48/60]/24W
IR
IN
G
SC
H
EM
A
TI
C
ORDERING INFO LPS
SERIES WATTAGE / VOLTAGE / TYPE
DL-PS-
WP24/24 - 24 Watt 24 Volt wall-plug
24/24 - 24 Watt 24 Volt wall-plug
48/24 - 48 Watt 24 Volt wall-plug
60/24 - 60 Watt 24 Volt wall-plug
ORDERING INFO CL2
SERIES WATTAGE / VOLTAGE
DL-PS-
60/24 - 60 Watt 24 Volt wall-plug
90/24 - 90 Watt 24 Volt wall-plug
100/24 - 96 Watt 24 Volt wall-plug
TYPE
-CL2
DL-PS-WP24/24
24W
1.0A
120V AC
24V DC
0.80
1 3/4"
3 1/4"
1 1/4"
MODEL
RATED POWER
RATED CURRENT
INPUT
DC OUTPUT
POWER FACTOR
WIDTH W
LENGTH L
HEIGHT H
DL-PS-24/24
34W
1.0A
120V AC
24V DC
0.80
1 1/2"
3 1/2"
1"
DL-PS-48/24
48W
2.0A
120V AC
24V DC
0.84
2"
4 ⅜"
1 ⅛"
DL-PS-60/24
60W
2.5A
120V AC
24V DC
0.80
1 1/2"
4 3/8"
1 1/2"
DL-PS-60/24-CL2
60W
2.5A
120V AC
24V DC
0.80
2 1/16"
5 1/8"
1 3/8"
MODEL
RATED POWER
RATED CURRENT
INPUT
DC OUTPUT
POWER FACTOR
WIDTH W
LENGTH L
HEIGHT H
DL-PS-90/24-CL2
90W
3.8A
120V AC
24V DC
0.80
2 1/16"
5 1/8"
1 3/8"
DL-PS-100/24-CL2
96W
4.0A
120V AC
24V DC
0.88
2 ¾"
7 7/8"
1 3/8"
LED POWER SUPPLIES • 24V DC • PLUG & PLAY
0 -10V
RECEIVER
RF
Requires LC-RF-400 receiver and controller
LPS
CLASS 2
INDOOR
0 -10 dimming required additional interface LC-DIM5A
0 -10V
RECEIVER
RF
Requires LC-RF-400 receiver and controller
INDOOR
0 -10 dimming required additional interface LC-DIM5A
© 2024 JESCO LIGHTING GROUP, LLC
OF
Specifications subject to change without notice REV. 02/28/2024
800 527 7796 855 265 5768
800 527 7796 855 265 5768 support@jescolighting.com…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .