2024-11-05_REV_1_HAVEN_ON_VINE-1B-FHA_FULL_SET.pdf
PDF 8 MB Posted
- Solicitation number
- IFB2024-007
- Issued by
- Polk County, Lake Harbor CDP, Florida
About this file
This comprehensive architectural and engineering document set is for the Haven on Vine Project, a renovation initiative by the City of Kissimmee, Florida, focusing on converting two first-floor apartments (I1 and I2 in Building I) into accessible units that comply with FHA (Federal Housing Administration) standards. The project involves a complete interior renovation of approximately 746 square feet per unit, including redesigning and constructing accessible living spaces with specific modifications such as access ramps, accessible kitchen and bathroom layouts, and ensuring accessible floor and entrance clearances throughout. The design documents detail comprehensive modifications to meet the Florida Building Code (8th Edition, 2023), NFPA standards, and specific accessibility requirements.
The renovation scope encompasses substantial upgrades to electrical, plumbing, and architectural elements, with a focus on creating fully ADA-compliant living spaces. The project is funded through multiple sources including American Rescue Funds, County and City resources, HOME Investment Partnerships, and Community Development Block Grant dollars. Specific improvements include installing new plumbing pipes, electrical wiring, HVAC systems, flooring, kitchens, bathrooms, water heaters, fixtures, and appliances. The design emphasizes detailed accessibility features like grab bars, wheelchair-accessible bathroom layouts, lever-style handles, and appropriate clearance measurements to ensure full compliance with current accessibility standards. The total project is part of a larger transformation of an old hotel into a mixed-use housing development with 40 emergency housing units and 80 apartment units targeting very low- and moderate-income residents.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BR
O
NSO
N D r.
BR
O
NSO
N D r.
HO
LL
YW
O
OD
ST
HO
LL
YW
O
OD
ST
BRONSON Dr.
M
EADOW
Dr
P E T
T
IS
B L V D
PARKING
PA
RK
IN
G
EA
ST
G U
ES
T
UN
IT
B
UIL
DIN
G
STORAGE
BUILDING
PA
RK
IN
G
BU
IL
D
IN
G "B
BU
IL
D
IN
G "E
WEST GUEST UNIT BUILDING
POOL
BU
IL
D
IN
G "F
BU
IL
D
IN
G "A
BU
IL
D
IN
G "J
BU
IL
D
IN
G "I
BU
IL
D
IN
G "C
BU
IL
D
IN
G "H
BU
IL
D
IN
G "D
BU
IL
D
IN
G "G
V I N E S T R E E T
L A
V O
N
E M
O R
Y
M A
I N
S
T R
E E
T
B E
R M
U D
A
A V
E N
U E
H I G H W A Y 1 9 2
1815 W. VINE ST.
REVISION TABLE
REV #
REV
DATE
REV DESCRIPTION
1 10/30/24 AHJ COMMENTS
HAVEN ON VINE 1B - FHA
ENGINEEROWNER GENERAL CONTRACTOR ARCHITECT MEP
Service Beyond Design
License No. AR102538 License No. CA30900
TO THE BEST OF THIS DESIGN PROFESSIONAL'S KNOWLEDGE, THESE PLANS AND SPECIFICATIONS
COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE FIRE SAFETY
STANDARDS AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH CHAPTER 553 AND
633 OF THE FLORIDA STATUTES AND MEET OR EXCEED THE REQUIREMENTS OF THE FLORIDA
BUILDING CODE - EXISTING BUILDING 8TH EDITION (2023), AS DEVELOPED AND MAINTAINED BY THE
FLORIDA BUILDING COMMISSION, AND ADMINISTERED AND ENFORCED BY LOCAL JURISDICTIONS.
= 34
ARCHITECTURAL SYMBOLS
# SECTION INDICATOR
SHEET NUMBER
# DETAIL NUMBER
SHEET NUMBER
REFERENCE NUMBER
REVISION NUMBER
REFER TO TITLE SHEET
RENOVATE THE 2 EXISTING APARTMENTS ON FIRST
FLOOR FOR BUILDING "I", INTO 2 ACCESSIBLE UNITS.
REDESIGN AND CONSTRUCT THE UNITS WITH FHA
FACILITIES: ACCESS RAMPS, ACCESSIBLE KITCHEN
AND BATHROOM LAYOUTS, AND ACCESSIBLE FLOOR
AND ENTRANCE CLEARANCES THROUGHOUT.
R - 2
V - B
THIS PROJECT MUST COMPLY WITH THE FOLLOWING CODES:
FLORIDA BUILDING CODE - BUILDING 8TH EDITION (2023)
NFPA 90A STANDARD FOR THE INSTALLATION OF
AIR-CONDITIONING AND VENTILATING SYSTEMS, 2021 EDITION.
NFPA 90B, STANDARD FOR THE INSTALLATION OF WARM AIR
HEATING AND AIR-CONDITIONING SYSTEMS, 2021 EDITION.
FLORIDA FIRE PREVENTION CODE 8TH EDITION (2021)
NFPA 70 NATIONAL ELECTRIC CODE (2020)
NFPA 1 2021 EDITION
NFPA 101 LIFE SAFETY CODE, 2021 EDITION
NFPA 241: STANDARD FOR SAFEGUARDING CONSTRUCTION,
ALTERATION AND DEMOLITION OPERATIONS, 2019 EDITION.
SPRINKLERSCALE:
SITE LOCATION
N/A
SCALE:
VICINITY MAP
N/A
C FOREFRONT ARCHITECTURE & ENGINEERING LLC 2014 THIS DOCUMENT AND/OR THE DESIGN CONCEPTS EXPRESSED HEREIN ARE THE PROPERTY OF FOREFRONT ARCHITECTURE & ENGINEERING LLC AND ALL RIGHTS OF OWNERSHIP, INCLUDING COPYRIGHT OF INTELLECTUAL PROPERTY, ARE RESERVED. ANY REPRODUCTIONS, COPYING, OR USE OF THIS DOCUMENT AND/OR THE DESIGN CONCEPT WITHOUT THE WRITTEN CONSENT OF FOREFRONT ARCHITECTURE & ENGINEERING LLC IS STRICTLY PROHIBITED AND PROTECTED BY UNITED STATES AND INTERNATIONAL LAW. IF PRINTED ON 11X17 SCALE IS HALF THE SIZE NOTED.J:\City of Kissimmee\Jobs\Haven on Vine 1B\24-14065-02\Dwgs\Sheets\Architectural\A000 COVER SHEET-FHA ; Plot Date: Monday, November 04, 2024 ,4:08:07 PM ; Plotted By: minelg
JO
B N
A M
E
S H
E E T N
A M
E
ISSUE - REVISION LOG
AR102538 - CA30900
H A V E N
O N
V
IN
E
P H
A S E
B W
E S T V
IN
E S
T R E E T K
IS
S
IM
M E E F L
S E A L
M A R K
D A T E
D E S C R
IP
T
IO
N
1230 Oakley Seaver Drive, Suite 100
Clermont, Florida 34711
888.850.FFAE (3323)
www.forefrontae.com
JOB # :
SHEET NUMBER :
24-14065
DATE : 11/05/2024
Cabral Egineering Inc.
SCALE:
MAP
N/A
SHEET LIST TABLE
SHEET
SHEET TITLE Rev-No. Rev_Date
A000 COVER SHEET 1 10/30/24
A001 GENERAL NOTES 00/00/00
A002 OVERALL SITE PLAN 1 10/30/24
A100 EXISTING AND DEMOLITION FIRST FLOOR PLAN -
BUILDING I
1 10/30/24
A101 PROPOSED FIRST FLOOR PLAN 1 10/30/24
A102 PROPOSED LIFE SAFETY PLAN FIRST FLOOR 1 10/30/24
A200 PROPOSED REFLECTED CEILING PLAN 1 10/30/24
A300 PROPOSED ENLARGED AND INTERIOR ELEVATIONS -
KITCHEN-BATH
1 10/30/24
A400 DOORS AND FINISHES SCHEDULES 1 10/30/24
A401 FHA DETAILS 00/00/00
E001 ELECTRICAL - GENERAL 1 10/30/24
E101 SITE ELECTRICAL PLAN 1 10/30/24
E201 ELECTRICAL PLANS - FIRST FLOOR - FHA 1 10/30/24
E801 ELECTRICAL DIAGRAMS AND SCHEDULES 1 10/30/24
E802 ELECTRICAL DIAGRAMS AND SCHEDULES 1 10/30/24
E901 ELECTRICAL DETAILS 00/00/00
P100 PLUMBING LEGENDS, ABBREVIATION AND INDEX 00/00/00
P101 PLUMBING SPECIFICATIONS 00/00/00
MP200 PLUMBING, MECHANICAL DEMO PLAN 00/00/00
P301 PLUMBING ENLARGE PLAN - SANITARY, WATER 1 10/30/24
P400 PLUMBING FIXTURE SCHEDULE 00/00/00
SCALE:
AREA OF WORK
N/A
APT. I1 AND I2 (BUILDING I)
APT.I1 APT.I2
lennardd Text Box
GENERAL NOTES PAINT & WALL COVERING NOTES CEILING NOTES
FLOORING NOTESDOOR NOTES
CLEANING NOTES
DEMOLITION NOTES
CEILING NOTES
PAINT & WALL COVERING NOTES
PATCHING NOTES
1. THESE DOCUMENTS HAVE BEEN PREPARED EXPRESSLY FOR USE BY
FOR THE PURPOSE OF BUILDING.
2. ANY ADDITIONAL USE OF THESE DOCUMENTS FOR ANY REASON OTHER
THAN THAT MENTIONED ABOVE MUST BE AUTHORIZED IN WRITING BY
THE COPYRIGHT HOLDER.
3. THESE DRAWINGS REFLECT DESIGN INTENT.
4. THESE DRAWINGS, AS LISTED IN THE DRAWING INDEX, ALONG WITH THE
SPECIFICATIONS & CONTRACT FOR CONSTRUCTION, CONSTITUTE THE
INSTRUMENTS OF SERVICE AND ARE CONSIDERED A SINGLE ENTITY. THE
CONTRACTOR IS THEREFORE BOUND BY ALL INFORMATION INCLUDED.
5. ONLY DRAWINGS MARKED 'ISSUED FOR CONSTRUCTION'
SHALL BE USED AS A BASIS FOR CONSTRUCTION.
6. THE TERM 'CONTRACTOR' IN THE PLANS SHALL REFER TO THE GENERAL
CONTRACTOR. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL
CONTRACTOR TO COORDINATE THE SUBCONTRACTOR WORK WITH
THESE PROJECT DOCUMENTS. CONTRACTOR SHALL PROVIDE A LIST OF
ALL SUB-CONTRACTORS TO THE CONSTRUCTION PROJECT MANAGER.
7. CONTACT CONSTRUCTION PROJECT MANAGER FOR
COORDINATION OF STAGING AND REFUSE REMOVAL PRIOR TO SIGNING
THE CONTRACT FOR CONSTRUCTION. ANY ADJUSTMENT IN THE
CONTRACT AMOUNT OR DURATION DUE TO REQUIREMENTS
SHALL BE MADE PRIOR TO CONTRACT EXECUTION.
8. ALL ITEMS SHOWN ARE NEW TO BE PROVIDED & INSTALLED BY G.C.
UNLESS NOTED OTHERWISE.
9. DO NOT SCALE DRAWINGS - WRITTEN DIMENSIONS TAKE PRECEDENT.
LARGE SCALE DRAWINGS TAKE PRECEDENCE OVER SMALL SCALE
DRAWINGS. DETAILS TAKE PRECEDENCE OVER ALL.
10. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DIMENSIONS AND
CONDITIONS PRIOR TO BID AND CONSTRUCTION. CONTRACTOR SHALL
NOTIFY THE CONSTRUCTION PROJECT MANAGER AND THE
ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES OR OMISSIONS PRIOR
TO PROCEEDING WITH ANY WORK.
11. FOR BIDDING PURPOSES; WHERE CONFLICTS EXIST BETWEEN DRAWING
DETAILS & SPECIFICATIONS, THE MORE STRINGENT SPECIFICATION
SHALL APPLY.
12. PRIOR TO SUBMITTING A PROPOSAL, ALL CONTRACTORS SHALL VISIT
THE SITE TO FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND
THE NATURE AND SCOPE OF THE WORK. THE SUBMISSION OF A
PROPOSAL SHALL BE CONSTRUED AS EVIDENCE THAT SUCH A SITE VISIT
HAS BEEN MADE, AND LATE CLAIMS FOR LABOR, EQUIPMENT OR
MATERIALS REQUIRED FOR DIFFICULTIES ENCOUNTERED, WHICH COULD
HAVE BEEN FORESEEN HAD SUCH AN EXAMINATION BEEN MADE, WILL
NOT BE RECOGNIZED.
13. THE GENERAL CONTRACTOR / SUB-CONTRACTOR SHALL OBTAIN AND
PAY FOR ALL THE LEGALLY REQUIRED APPROVAL AND PERMITS
NECESSARY FOR THE EXECUTION AND COMPLETION OF THE FORWARD
COPIES TO THE TENANT CONSTRUCTION PROJECT MANAGER .
14. ALL WORK PERFORMED BY THE CONTRACTOR / SUB-CONTRACTOR
SHALL CONFORM TO THE REQUIREMENTS OF THE MUNICIPAL, LOCAL,
AND STATE AND FEDERAL LAWS, AS WELL AS ANY OTHER GOVERNING
REQUIREMENTS, INCLUDING LANDLORD REQUIREMENTS, WHETHER OR
NOT SPECIFIED ON THE DRAWINGS.
15. WHERE THE CONTRACT NOTES OR DRAWINGS CALL FOR ANY WORK OR
A MORE STRINGENT NATURE THAN THAT REQUIRED BY THE BUILDING
CODE OR ANY OTHER DEPARTMENT HAVING JURISDICTION OVER THE
WORK, THE WORK OF THE MORE STRINGENT NATURE CALLED FOR BY
THE CONTRACT NOTES OR DRAWINGS SHALL BE FURNISHED IN ALL
CASES.
16. ALL CONTRACTORS SHALL CONTACT THE BUILDING
MANAGEMENT/LANDLORD TO DETERMINE THE RULES OF THE BUILDING
OWNER FOR CONSTRUCTION AND DELIVERY OF EQUIPMENT AND
MATERIALS.
17. PRIOR TO BEGINNING ANY WORK, THE GENERAL CONTRACTOR SHALL
FURNISH THE ARCHITECT WITH A CONSTRUCTION SCHEDULE SHOWING THE
CHRONOLOGICAL PHASES OF HIS WORK AND ALL RELATED WORK FOR THE
COMPLETION OF THE PROJECT. THIS SCHEDULE SHALL INDICATE ALL ORDERING LEAD
TIMES, LENGTH OF TIME FOR EACH PHASE AND THE PROJECTED START AND
COMPLETE DATES.
18. IT IS ASSUMED THAT THE G.C. SHALL PERFORM THE WORK AS
ILLUSTRATED WITHIN THE PERMITTED DRAWINGS. THE CONTRACTOR
SHALL NOTIFY THE ARCHITECT IN THE EVENT THAT EXISTING SITE
CONDITIONS PREVENT THE WORK FROM BEING COMPLETED AS
ILLUSTRATED HEREIN SO THAT ANY MODIFICATIONS TO THE
CONSTRUCTION DOCUMENTS (IF NECESSARY) CAN BE MADE. ANY
DEVIATIONS FROM THE PERMITTED DRAWINGS WILL NOT BE
ACCEPTABLE, AND THE CONTRACTOR SHALL RECONFIGURE THE WORK
AT HIS OWN EXPENSE, AS REQUIRED TO BE IN CONFORMANCE WITH THE
PERMITTED DOCUMENTS. THE ARCHITECT WILL NOT ACCEPT, CERTIFY,
OR DOCUMENT ANY WORK THAT DOES NOT CONFORM TO THE
PERMITTED DOCUMENTS FOR THE PURPOSES OF OBTAINING ANY
ADDITIONAL MUNICIPAL APPROVAL REQUIRED DUE TO UNAUTHORIZED
REVISIONS.
19. THE GENERAL CONTRACTOR SHALL MAINTAIN A CURRENT AND
COMPLETE SET OF CONSTRUCTION DRAWINGS ON SITE THROUGHOUT
THE DURATION OF CONSTRUCTION FOR USE BY ALL TRADES.
20. ALL DEBRIS SHALL BE REMOVED FROM THE PREMISES, AND WORK
AREAS SHALL BE LEFT IN A CLEAN CONDITION ON A DAILY BASIS.
21. THE GENERAL CONTRACTOR SHALL EXERCISE STRICT DUST
CONTAINMENT CONTROL OVER THE JOB SITE TO PREVENT DUST FROM
ESCAPING.
22. THE GENERAL CONTRACTOR SHALL PROPERLY PROTECT THE GENERAL
BUILDING AREAS AND ANY ADJOINING PROPERTY OR WORK FROM
DAMAGE DURING CONSTRUCTION, AND SHALL PATCH OR REPLACE ANY
DAMAGED WORK OR MATERIALS WITHOUT DELAY.
23. ANY DAMAGE BY G.C. OR SUBCONTRACTOR TO EXISTING ASPHALT
PAVEMENT AND/OR EXISTING LANDSCAPING OUTSIDE OF
CONSTRUCTION LIMIT LINE SHALL BE REPAIRED AT NO COST TO OWNER OR TENANT.
24. DURING THE ENTIRE PERIOD OF DEMOLITION AND CONSTRUCTION. ALL
REQUIRED EXITS AND EGRESS PATHWAYS SHALL BE CONTINUOUSLY
MAINTAINED FREE FROM ALL OBSTRUCTIONS AND IMPEDIMENTS IN THE
CASE OF A FIRE OR OTHER EMERGENCY. ALL EXISTING EXIT LIGHTING,
FIRE PROTECTIVE DEVICES AND ALARMS SHALL BE CONTINUOUSLY
MAINTAINED.
25. NO MATERIALS SHALL BE STORED ON PUBLIC PROPERTY UNLESS AN
ENCROACHMENT PERMIT IS FIRST OBTAINED FROM THE PUBLIC WORKS
DEPT.
26. EACH TRADE SHALL PROVIDE CAULKING OR SEALANT WHERE REQUIRED.
27. PROVIDE STRUCTURAL SUPPORTS AS REQUIRED AT ALL WALL MOUNTED
EQUIPMENT, CABINETS, PLUMBING AND LIGHT FIXTURES.
28. MANUFACTURER'S NAME, TRADEMARK, LOGOS, ETC., SHALL NOT BE
VISIBLE TO THE PUBLIC.
29. ALL FLOOR SLAB CUTTING, TRENCHING AND REMOVAL SHALL BE
REPLACED WITH THE SAME MATERIAL IN THE SAME THICKNESS OF THE
ADJACENT FLOOR MATERIAL. ADDITIONAL CONCRETE PATCHING SHALL
BE DOWELED INTO THE ADJACENT CONCRETE SLAB TO MINIMIZE
DIFFERENTIAL SETTLEMENT OF THE FLOOR SYSTEM.
30. ALL ROOF PENETRATIONS ARE TO BE PERFORMED BY
PROJECT/CONSTRUCTION MANAGER'S ROOFING CONTRACTOR.
CONTACT PROJECT/CONSTRUCTION MANAGER TO COORDINATE.
31.ALL WALL, FLOOR, CEILING, ETC. PENETRATIONS ARE TO BE DRAFT OR
FIRESTOPPED (WHERE REQUIRED TO MATCH FIRE COMPARTMENTS). ASSURE NO AIR
LEAKAGE, PARTICULARLY WHEN A PLENUM IS IN USE.
1. THE GENERAL CONTRACTOR SHALL DO ALL CUTTING, FITTING, AND
PATCHING WORK THAT MAY BE REQUIRED TO MAKE ALL PARTS COME
TOGETHER PROPERLY AND FIT TO RECEIVE OR BE RECEIVED BY WORK
OF OTHER CONTRACTORS SHOWN UPON OR REASONABLY IMPLIED BY
THE DRAWINGS AND NOTES.
2. THE GENERAL CONTRACTOR SHALL PROVIDE ALL FLOOR CUT-OUTS AND
PATCHING REQUIRED FOR THE INSTALLATION OF ALL WORK.
3. THE GENERAL CONTRACTOR SHALL SURVEY ALL EXISTING FINISHED
SURFACES INCLUDING CORNER BEADS, STOPS, ETC. FOR CHIPS, CRACK
HOLES, DAMAGED SURFACES AND DEFECTS AND REPAIR SAME TO THE
SATISFACTION OF PROJECT MANAGER.
4. WHERE DOOR BUCKS HAVE BEEN REMOVED, REPAIR GAPS AND
SURFACES TO ACHIEVE A CLASS I FINISH TO THE SATISFACTION OF
CONSTRUCTION PROJECT MANAGER.
5. THE GENERAL CONTRACTOR SHALL PROVIDE METAL LATH OVER ALL NEW
CONDUIT CHASES IN MASONRY PARTITIONS.
6. ALL DAMAGED EXISTING AREAS TO REMAIN AND EXISTING AREAS
AFFECTED BY DEMOLITION OR NEW CONSTRUCTION WORK SHOWN ON
DRAWINGS SHALL BE PATCHED AS REQUIRED TO MATCH IMMEDIATE
EXISTING ADJACENT AREAS IN MATERIALS, FIRE RATING, FINISH AND
COLOR UNLESS OTHERWISE NOTED.
7. ALL FIRE PROOFING REMOVED FROM COLUMNS AND BEAMS DURING THE
COURSE OF CONSTRUCTION SHALL BE REPLACED WITH THE SAME
MATERIAL AND RATING AS THAT WHICH WAS REMOVED.
1. UNLESS OTHERWISE SPECIFIED, ALL AREAS ARE TO BE PAINTED IN
ACCORDANCE WITH FINISH PLANS.
2. WALLS SHALL INCLUDE SURFACES FROM FLOOR TO CEILING, INCLUDING
PILASTERS, FACIAS, JAMBS BUCKS, REVEALS, RETURNS, AND ALL
VERTICAL SURFACES NOT INCLUDED IN CEILING.
3. PAINT COLORS SHALL BE SPECIFIED BY THE OWNER AND THE GENERAL
CONTRACTOR SHALL SUBMIT 3 SAMPLES (12" X 12") FOR REVIEW BY THE
OWNER / ARCHITECT.
4. ALL WALLS AND CEILINGS SHALL BE PROPERLY PREPARED, SPACKLE,
SANDED, ETC. TO PROVIDE A PERFECTLY SMOOTH FINISH AND SURFACE
READY FOR PRIME AND PAINT.
5. ALL EXISTING LOOSE PAINT SHALL BE REMOVED AND SPACKLE OR
PLASTER PATCHED.
6. ALL EXISTING UNEVENNESS IN ALL PARTITIONS SHALL BE SANDED OR
CHIPPED AWAY AND SURFACES PLASTER-PATCHED OR SPACKLE TO
INSURE A PERFECTLY EVEN SURFACE.
7. ALL WOOD SHELVING AND PAINTED DOORS SHALL RECEIVE PRIMING,
SANDING AND TWO FULL COATS OF SEMI-GLOSS ENAMEL FREE OF BRUSH
MARKS, UNLESS OTHERWISE NOTED.
8. THE CONTRACTOR SHALL REMOVE ALL ELECTRICAL SWITCH PLATES AND
OUTLET PLATES, SURFACE HARDWARE, ETC., PRIOR TO PAINTING,
PROTECTING AND REPLACING SAME WHEN PAINTING HAS BEEN
COMPLETED. HE SHALL REMOVE ALL PAINT FROM WHERE IT HAS SPILLED,
SPLASHED OR SPLATTERED ON SURFACES, INCLUDING BUT NOT LIMITED
TO LIGHT FIXTURES, DIFFUSERS, REGISTERS AND SLAB FITTINGS, ETC.
9. THE CONTRACTOR SHALL USE A LATEX BASE PAINT IN COLORS AND
FINISHES SELECTED BY THE ARCHITECT. HE SHALL PROPERLY PREPARE
ALL SURFACES TO RECEIVE ONE (1) PRIME COAT AND TWO (2) FINISH
COAST OF PAINT IN COLOR SELECTED BY THE ARCHITECT.
10. THE CONTRACTOR SHALL EXAMINE ALL AREAS OF CONSTRUCTION AFTER
COMPLETION OF WORK BY ALL TRADES (INCLUDING TELEPHONE
INSTALLATION, FLOORING, ETC.) AND INDICATE ALL NECESSARY
"TOUCH-UP" PAINTING AND/OR PATCHING.
11. IT IS THE INTENT OF THE DRAWINGS THAT ALL EXPOSED SURFACES
RECEIVE FINISHES AS INDICATED ON THE DRAWINGS OR IN THE
SPECIFICATIONS UNLESS SPECIFICALLY NOTED OTHERWISE.ANY
SURFACES WHICH DO NOT HAVE A SPECIFIC FINISH NOTED OR ARE
NOTED TO REMAIN UNFINISHED SHALL BE BROUGHT TO THE ATTENTION
OF THE ARCHITECT AND FINISHED PER THE ARCHITECT'S INSTRUCTION.
12. PAINT FRONT SIDE, BACK SIDE AND DOOR EDGES AT STRIKE SIDE AND
HINGE SIDE. LEAVE TOP AND BOTTOM UNPAINTED TO PREVENT
WARPING.
13. PAINT ALL METAL ACCESS DOORS AND ACCESS PANELS TO MATCH
ADJACENT WALL OR CEILING FINISH. GRAPHICS ON DOOR OR PANEL (IF
ANY) ARE TO BE REPAINTED/RE-APPLIED TO MATCH EXISTING, IF
APPLICABLE.
14. CLOSET WALL SURFACES ARE TO BE PAINTED TO MATCH THE COLOR OF
THE ADJACENT OUTSIDE WALL SURFACES.
1. THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL REQUIRED
BUCKS AND ASSEMBLIES AS SHOWN ON ARCHITECTURAL DRAWINGS
UNLESS OTHERWISE NOTED.
2. THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL DOORS AS
SPECIFIED ON THE ARCHITECTURAL DRAWINGS UNLESS OTHERWISE
NOTED.
3. ALL LOCK SETS SHALL BE CODED AND/OR KEYED IN ACCORDANCE WITH
THE BUILDING REQUIREMENTS. CODES AND/OR KEYS ARE TO BE
DELIVERED TO TENANT PROPERLY TESTED AND/OR TAGGED. THE
NUMBER OF MASTER AND PASS KEYS SHALL BE COORDINATED WITH
BUILDING MANAGEMENT.
4. DETAILED DOOR AND HARDWARE SCHEDULES SHALL BE SUBMITTED TO
THE ARCHITECT FOR REVIEW, AND FABRICATION OF MATERIAL SHALL
NOT BE COMMENCED UNTIL SUCH REVIEW HAS BEEN RETURNED.
5. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 8 1/2
POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR INTERIOR DOORS,
SUCH PULL/PUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED
DOORS AND AT THE CENTER PLANE OF THE SLIDING OR FOLDING DOORS.
COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE
UTILIZED TO MEET THE ABOVE WHEN FIRE DOORS ARE REQUIRED, THE
MAXIMUM EFFORT TO OPERATE THE DOOR MAY BE INCREASED TO THE
MINIMUM ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE, NOT TO
EXCEED 15 POUNDS.
6. THE BOTTOM 10" OF ALL DOORS (EXCEPT SLIDING AND AUTOMATIC)
SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE.
7. ALL REQUIRED EXIT DOORWAYS SHALL HAVE A MINIMUM 32" CLEAR
OPENING WITH THE DOOR AT 90° TO THE CLOSED POSITION.
8. WHERE DOORS ARE IN PAIRS, ONE OF A PAIR OF DOORS SHALL MEET
THE MINIMUM WIDTH REQUIREMENTS
9. MAXIMUM HEIGHT OF THRESHOLD TO BE 1/2" MAXIMUM VERTICAL
CHANGE AT EDGE IS 1/4" WITH A MAXIMUN BEVEL OF 45°.
10. LATCHING AND LOCKING DOORS THAT ARE HAND-ACTIVATED AND WHICH
ARE IN THE PATH OF TRAVEL SHALL BE OPERABLE WITH A SINGLE
EFFORT BY LEVER TYPE HARDWARE, PANIC BARS, PUSH PULL
ACTIVATING BARS, OR BARS OR OTHER HARDWARE DESIGNED TO
PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE
OPENING HARDWARE.
11. SEE SHEET A8.1 FOR REQUIREMENTS OF DOORS, WINDOWS, AND
HARDWARE, DOOR SCHEDULE, HARDWARE SCHEDULE AND DOOR AND
WINDOW DETAILS.
12. DIMENSIONS TO EDGE OF DOOR LOCATING DOOR OPENINGS ARE TO
INSIDE FACE OF JAMB, UNLESS OTHERWISE NOTED.
13. DOOR OPENINGS ARE TO BE LOCATED SO THAT INSIDE FACE OF BUTT
SIDE JAMB IS 4" FROM FACE OF PERPENDICULAR WALL AT CORNER,
ALLOWING FOR A 90 DEGREE SWING TYPICAL, UNLESS OTHERWISE
NOTED.
14. SEE SHEET A8.1 FOR SPECIFIC DOOR AND HARDWARE REQUIREMENTS.
15. UNDERCUT BUILDING STANDARD INTERIOR DOORS AS REQUIRED TO
CLEAR FINISHED FLOOR BY 1/4". ALL RATED DOORS SHALL BE ORDERED
SO AS TO CLEAR THE FINISHED FLOOR BY 1/4", UNLESS OTHERWISE
NOTED.
16. UNDERCUT RESTROOM DOORS 3/4" TO PROVIDE RETURN AIR FLOW FOR
NEGATIVE AIR FLOW FOR EXHAUST FANS.
17. ANY GLAZING ON OR WITHIN 24" OF A DOOR (IN THE SAME PLANE) SHALL
BE TEMPERED.
1. FACIAS OR ANY BREAK IN THE CEILING HEIGHTS CREATED BY THE
INSTALLATION AND/OR ALTERATION OF HEATING, VENTILATING, AIR
CONDITIONING OF MECHANICAL DUCTS, PIPING OR OTHER EQUIPMENT
SHALL BE FORMED OF GYPSUM WALLBOARD ON FURRING CHANNELS.
HUNG CEILING HEIGHTS SHALL BE AS SHOWN ON ARCHITECTURAL
DRAWINGS AND DETAILS.
2. ANY DEVIATION FROM HEIGHTS SHOWN WILL BE SUBMITTED TO THE
CONSTRUCTION AND ARCHITECT PROJECT MANAGER FOR REVIEW.
3. THE GENERAL CONTRACTORS CEILING CONTRACTOR SHALL CLOSELY
COORDINATE HIS WORK WITH THAT OF THE FIXTURE, PLUMBING HVAC
ELECTRICAL CONTRACTORS AND THE TELEPHONE COMPANY WHENEVER
THEIR RESPECTIVE WORK IS CONTIGUOUS.
4. THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL CEILING
ACCESS PANELS IN GYPSUM BOARD CEILINGS AS REQUIRED TO FURNISH
ACCESS TO ALL AIR HANDLING UNITS, PHONE AND ELECTRICAL
CONTROLS AS REQUIRED BY LOCAL BUILDING CODES. COORDINATE
LOCATIONS WITH CONSTRUCTION PROJECT MANAGER AND ARCHITECT PRIOR TO FINAL
INSTALLATION.
5. PRIOR TO CLOSING UP ANY CEILING, ALL PLENUM SYSTEMS (HVAC,
PLUMBING AND ELECTRIC) SHALL BE INSPECTED AND WHERE REQUIRED,
TESTED BY CONTRACTOR'S ENGINEERS AND BY AUTHORITIES HAVING
JURISDICTION TO INSURE THEIR PROPER INSTALLATION AND FUNCTION.
6. THE CEILING TILE JOINTS SHALL BE ALIGNED PERFECTLY WITH RECESSED
LIGHTING FIXTURES.
7. ALL JOINTS IN THE TILE FIELD SHALL BE SQUARE, LEVEL, AND PERFECTLY
ALIGNED WITH EACH OTHER AND WITH THE RECESSED LIGHTING
FIXTURES.
8. CEILINGS IN CLOSETS SHALL BE OF THE SAME HEIGHTS AND
CONSTRUCTION AS THAT OF ADJOINING SPACE, EXCEPT AS OTHERWISE
NOTED.
9. THE GENERAL CONTRACTOR SHALL PROVIDE CUT-OUTS AND OTHER
SPECIAL PROVISIONS IN ACOUSTICAL WORK AS REQUIRED FOR LIGHTING
FIXTURES, REGISTERS, DIFFUSERS AND OTHER INSERTED ITEMS.
10. SUSPENDED CEILING SHALL BE CONSTRUCTED IN ACCORDANCE WITH
STATE AND LOCAL CODE FOR FIREPROOF STRUCTURES AND SMOKE
CONTROL.
11. THE GENERAL CONTRACTOR SHALL REPAIR AND/OR REPLACE ANY AND
ALL CEILING TILES WHICH ARE REMOVED TO FACILITATE PLENUM
SYSTEM INSTALLATIONS.
12. THE GENERAL CONTRACTOR WILL NOT BE ENTITLED TO EXTRAS FOR
OPENING ANY CEILING BECAUSE OF TELEPHONE INSTALLATION,
SECURITY SYSTEMS OR COMPUTER DATA SYSTEMS.
13. PROVIDE BLOCKING/BACKING AND CEILING REINFORCEMENT FOR ALL
CEILING MOUNTED ITEMS, (PLASMA SCREENS, ETC.).
1. THE GENERAL CONTRACTOR SHALL FLASH PATCH ALL CRACKS, HOLES
OR OTHER IMPERFECTIONS (PROJECTIONS SHALL BE REMOVED AND
PATCHED TO PROVIDE A CONTINUOUS SMOOTH FLOOR SURFACE). LEVEL
NOT TO EXCEED 1/4" IN 10-0" NON-CUMULATIVE.
2. THE GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT AFTER FLOOR
PATCHING IS DONE AND RECEIVE
THEIR REVIEW PRIOR TO INSTALLATION OF FINISHED FLOORING.
3. ALL NEW FLOORING IS TO BE INSTALLED BY GENERAL CONTRACTOR AND
SHALL BE AS SPECIFIED ON THE ARCHITECT'S CONSTRUCTION
DOCUMENTS.
4. ALL WORKMANSHIP SHALL BE OF THE BEST QUALITY AND WHEN THE
WORK IS COMPLETE, IT SHALL BE FREE FROM BUCKLES, BUBBLES, OPEN
JOINTS OR OTHER IMPERFECTIONS. SEAMS SHALL BE KEPT IN ACCURATE
ALIGNMENT ALONG BOTH COORDINATES. TILE HAVING CHIPPED OR
ROUNDED CORNERS WILL BE REJECTED AND IF LAID, SHALL BE REMOVED
AND REPLACED WITH ACCEPTABLE TILE.
5. TILE SHALL BE LAID IN SQUARE PATTERN WITH COURSES PARALLEL TO
WALLS, UNLESS OTHERWISE NDICATED ON DRAWINGS. THE TILE SHALL
BE SECURELY CEMENTED AND SHALL BE LAID WITH TIGHT JOINTS.
6. THE ADHESIVE USED FOR CEMENTING TILE SHALL BE APPLIED FAR
ENOUGH IN ADVANCE OF THE SETTING TO PERMIT THE ADHESIVE TO
REACH ITS INITIAL SET BUT NOT ITS FINAL SET.
7. SPACES BEING SURFACED SHALL BE CLOSED TO TRAFFIC AND OTHER
WORK DURING THE LAYING OF FLOORING. TILE FLOORS SHALL BE
COVERED AFTER INSTALLATION FOR PROTECTION.
8. ALL RESILIENT BASE TO BE AS SPECIFIED PER PLANS..
9. UPON COMPLETION, ALL WORK SHALL BE CLEANED BY THE CONTRACTOR
REMOVING ALL SPOTS OF ADHESIVE AND SURFACE STAINS AND ALL
SCRAPS. CARTONS AND CONTAINERS SHALL BE REMOVED FROM THE
BUILDING.
10. AFTER CLEANING, THE GENERAL CONTRACTOR SHALL GIVE SHEET VINYL
FLOOR TWO (2) APPLICATIONS OF AN APPROVED NON-SLIP WAX WHICH IS
TO BE THOROUGHLY MACHINE BUFFED AND LEFT IN CONDITION ENTIRELY
SATISFACTORY TO THE OWNER .
11. THE GENERAL CONTRACTOR SHALL PROVIDE AND MAINTAIN ADEQUATE
PROTECTION FOR ALL RESILIENT FLOORING WORK FOR THE DURATION
OF THE CONTRACT, AND REMOVE ALL PROTECTION PRIOR TO PUNCH
LIST.
14. THE GENERAL CONTRACTOR TO COORDINATE ALL FLOORING
CONTRACTORS INVOLVED TO ASSURE FLUSH INSTALLATION OF ALL
VARYING FLOOR MATERIALS USED. ALL TRANSITION METHODS TO BE
APPROVED BY THE ARCHITECT .
15. PROVIDE BLACK RUBBER REDUCER STRIP WHERE ECO SURFACES
RUBBER FLOORING AND VCT TRANSITION OCCURS, UNLESS OTHERWISE
NOTED.
1. THE NEW ITEMS INSTALLED BY THE GENERAL CONTRACTOR IN ADDITION
TO BEING AMPLY PROTECTED THROUGHOUT THE PERIOD OF
CONSTRUCTION SHALL BE THOROUGHLY CLEANED TO THE SATISFACTION
OF THE PRIOR TO TURNOVER.
2. THE BASE BUILDING TOILET FACILITIES SHALL BE AMPLY PROTECTED
THROUGHOUT THE PERIOD OF CONSTRUCTION AND ALL DAMAGED OR
MALFUNCTIONING ITEMS SHALL BE REPAIRED, REPLACED AND/OR
THOROUGHLY CLEANED TO THE SATISFACTION OF THE CONSTRUCTION PROJECT
MANAGER PRIOR TO TURNOVER.
3. ALL CONSTRUCTION ACTIVITY IS TO NOT INTERFERE WITH THE DAILY OPERATING
OF THE EXISTING OFFICE BUILDING.
1. COORDINATE ALL DEMOLITION WITH FACILITIES.
2. ALL DEMOLITION MUST BE PERFORMED IN A MANNER TO CONTAIN DUST AND
PARTICLES.
3. AREA MUST REMAIN CLEAN, SAFE, AND OCCUPABLE.
4. ALL SYSTEMS MUST REMAIN FUNCTIONAL DURING DEMOLITION.
C FOREFRONT ARCHITECTURE & ENGINEERING LLC 2014 THIS DOCUMENT AND/OR THE DESIGN CONCEPTS EXPRESSED HEREIN ARE THE PROPERTY OF FOREFRONT ARCHITECTURE & ENGINEERING LLC AND ALL RIGHTS OF OWNERSHIP, INCLUDING COPYRIGHT OF INTELLECTUAL PROPERTY, ARE RESERVED. ANY REPRODUCTIONS, COPYING, OR USE OF THIS DOCUMENT AND/OR THE DESIGN CONCEPT WITHOUT THE WRITTEN CONSENT OF FOREFRONT ARCHITECTURE & ENGINEERING LLC IS STRICTLY PROHIBITED AND PROTECTED BY UNITED STATES AND INTERNATIONAL LAW. IF PRINTED ON 11X17 SCALE IS HALF THE SIZE NOTED.J:\City of Kissimmee\Jobs\Haven on Vine 1B\24-14065-02\Dwgs\Sheets\Architectural\A001 GENERAL NOTES-FHA ; Plot Date: Monday, November 04, 2024 ,3:36:21 PM ; Plotted By: minelg
JO
B N
A M
E
S H
E E T N
A M
E
ISSUE - REVISION LOG
AR102538 - CA30900
H A V E N
O N
V
IN
E
P H
A S E
B W
E S T V
IN
E S
T R E E T K
IS
S
IM
M E E F L
S E A L
M A R K
D A T E
D E S C R
IP
T
IO
N
1230 Oakley Seaver Drive, Suite 100
Clermont, Florida 34711
888.850.FFAE (3323)
www.forefrontae.com
JOB # :
SHEET NUMBER :
24-14065
DATE : 11/05/2024
Image
BR
O N
SO
N D r.
BR
O N
SO
N D r.
H O
LL
YW
O O D S
T.
BRONSON Dr.
M
EADO
W Dr
P E T T
IS
B L V D
V I N E S T R E E T - H I G H W A Y 1 9 2
PARKING
PA
RK
IN
G
EA
ST
G U
ES
T
UN
IT
B
UI
LD
IN
GPA
RK
IN
G
BU
IL
D
IN
G B"
BU
IL
D
IN
G E"
WEST GUEST UNIT BUILDING
POOL
BU
IL
D
IN
G F"
BU
IL
D
IN
G A"
BU
IL
D
IN
G J"
BU
IL
D
IN
G I"
BU
IL
D
IN
G C"
BU
IL
D
IN
G H
BU
IL
D
IN
G D
BU
IL
D
IN
G G
R A
M P
S L O
P E
/1
GRASS
0'-0"
30'-5"
R A M P
SLOPE 1:25
0'-8 1/4"
0'-0"
17'-5"
3'-9"14'-2"3'-9" GRASS
R A
M P
S L O
P E
/1
9'-10"22'-4"
5'-0"
0'-8 1/4"
GRASS
GRASS
GRASS
GRASS
GRASS
A002
27'-3"
-0'-6"
ACCESSIBLE
PARKING
SPACE SIGN
ACCESSIBLE
PARKING
SPACE SIGN
WHEEL
STOP
WHEEL
STOP
12'-0"
5'-0"
12'-0"
5'-0"
70°
GRASS
A
0'-0"
GROUND FLR.
5'-0"
CURB
RAMPWALKWAY PARKING
6'-0"
"0'-0"
-0'-6"
ADA RAMP
17'-5"
ADA RAMP
9'-10"
WALKWAY
0'-8 1/4" A.F.F.
FIN. FLR.
0'-0"
SCALE:
OVERALL SITE PLAN
N/S
C FOREFRONT ARCHITECTURE & ENGINEERING LLC 2014 THIS DOCUMENT AND/OR THE DESIGN CONCEPTS EXPRESSED HEREIN ARE THE PROPERTY OF FOREFRONT ARCHITECTURE & ENGINEERING LLC AND ALL RIGHTS OF OWNERSHIP, INCLUDING COPYRIGHT OF INTELLECTUAL PROPERTY, ARE RESERVED. ANY REPRODUCTIONS, COPYING, OR USE OF THIS DOCUMENT AND/OR THE DESIGN CONCEPT WITHOUT THE WRITTEN CONSENT OF FOREFRONT ARCHITECTURE & ENGINEERING LLC IS STRICTLY PROHIBITED AND PROTECTED BY UNITED STATES AND INTERNATIONAL LAW. IF PRINTED ON 11X17 SCALE IS HALF THE SIZE NOTED.J:\City of Kissimmee\Jobs\Haven on Vine 1B\24-14065-02\Dwgs\Sheets\Architectural\A002 OVERALL SITE PLAN-FHA ; Plot Date: Monday, November 04, 2024 ,3:36:32 PM ; Plotted By: minelg
JO
B N
A M
E
S H
E E T N
A M
E
ISSUE - REVISION LOG
AR102538 - CA30900
H A V E N
O N
V
IN
E
P H
A S E
B W
E S T V
IN
E S
T R E E T K
IS
S
IM
M E E F L
S E A L
M A R K
D A T E
D E S C R
IP
T
IO
N
1230 Oakley Seaver Drive, Suite 100
Clermont, Florida 34711
888.850.FFAE (3323)
www.forefrontae.com
JOB # :
SHEET NUMBER :
24-14065
DATE : 11/05/2024
/3
/2
SCALE:
ENLARGED ADA PARKING PLAN - BUILDING I
1/8"=1'-0"
SCALE:
ADA RAMP SECTION
1/8"=1'-0"
SCALE:
ADA RAMP SECTION
1/8"=1'-0"
PLAN NORTH
GENERAL DEMOLITION PLAN NOTES
1. THE DEMOLITION DRAWINGS HAVE BEEN DEVELOPED FROM EXISTING DRAWINGS WHICH
WERE PROVIDED TO THE ARCHITECT AND THEY MAY NOT REFLECT ACTUAL FIELD
CONDITIONS. PRIOR TO PROCEEDING WITH ANY WORK, THE CONTRACTOR SHALL
VERIFY THE ACCURACY OF THESE DRAWINGS IN COMPARISON TO THE EXISTING FIELD
CONDITIONS; AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT ANY INCONSISTENCIES
BETWEEN THE ACTUAL CONDITIONS AND THESE DRAWINGS.
2. THE GENERAL CONTRACTOR SHALL ALSO NOTIFY THE ARCHITECT IMMEDIATELY IF ANY
DEMOLITION OR NEW CONSTRUCTION WORK (AS INDICATED IN THE CONTRACT
DOCUMENTS) CAN NOT BE PERFORMED DUE TO EXISTING FIELD CONDITIONS.
3. IF ANY EXISTING FIRE PROOFING AND/OR RATED ASSEMBLIES (WHICH ARE SUPPOSED
TO REMAIN) ARE DAMAGED DURING DEMOLITION, THEY SHALL BE REPAIRED TO
CONFORM TO THE ORIGINAL FIRE PROTECTION REQUIREMENTS. ALSO, THE INTEGRITY
OF THE EXISTING RATED FLOOR, WALL, BARRIER AND ROOF ASSEMBLIES (WHICH ARE
SUPPOSED TO REMAIN) SHALL BE MAINTAINED THROUGH OUT ALL PHASES OF
CONSTRUCTION.
4. REMOVE EXISTING CONSTRUCTION AS INDICATED, TYPICAL WALL, REMOVAL SHALL
INCLUDE MECHANICAL, PLUMBING, ELECTRICAL, COMMUNICATIONS AND SECURITY
SYSTEMS CONTAINED THEREIN. REMOVE DOORS, CABINETWORK, CASEWORK,
WINDOWS, FRAMES, FINISHES, FIXTURES AND THEIR ATTACHMENTS AS REQUIRED.
AFTER REMOVAL, REPAIR HOLES IN EXISTING TO REMAIN FLOORS, WALL, BARRIERS AND
ROOFS TO COMPLY WITH ORIGINAL FIRE, SMOKE, AND SOUND ASSEMBLIES, FIRE
PROTECTION REQUIREMENTS, AND STRUCTURAL INTEGRITY. PREPARE SURFACES TO
RECEIVE NEW FINISHES AS SPECIFIED IN THESE DOCUMENTS OR AS SPECIFIED IN
SEPARATE INTERIOR DESIGN DOCUMENTS. WHERE A NEW FINISH IS CALLED FOR ON AN
EXISTING SURFACE, REMOVE THE EXISTING FINISH AND PREPARE TO RECEIVE NEW
FINISH. PREPARATIONS NEED TO FOLLOW THE MANUFACTURERS INSTRUCTIONS.
5. THE CONTRACTOR SHALL NOT CUT EXISTING OR NEW STRUCTURAL WORK IN ANY
MANNER THAT MAY RESULT IN A REDUCTION OF LOAD CARRYING OR LOAD/DEFLECTION
RATIO. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY STRUCTURAL CUTS
PRIOR TO EXECUTION SO THAT APPROVAL CAN BE OBTAINED IN ADVANCE FROM THE
ARCHITECT AND/OR STRUCTURAL ENGINEER.
6. WHERE EXISTING CONSTRUCTION IS FOUND TO CONTAIN ANY HAZARDOUS MATERIAL,
THE CONTRACTOR SHALL IMMEDIATELY INFORM THE OWNER AND THE ARCHITECT IN
WRITING. NOTE: REMOVAL, DISPOSAL AND REPLACEMENT OF THE HAZARDOUS
MATERIAL IS THE SOLE RESPONSIBILITY OF THE OWNER AND SHALL BE IN ACCORDANCE
WITH STATE, LOCAL AND FEDERAL REGULATIONS.
7. THE CONTRACTOR SHALL REPLACE ANY EXISTING TO REMAIN MATERIALS AND FINISHES
(CEILING GRID, CEILING TILE, GYPSUM BOARD, FINISHES, DOORS, FRAMES, WALL
PROTECTION ETC.) WHICH ARE DAMAGED DURING DEMOLITION OR CONSTRUCTION.
8. REMOVE ALL EXISTING CONDUIT, WIRING AND DEVICES RENDERED USELESS DUE TO
CHANGES IN THE EXISTING AREA
9. PATCH ALL CUTS, OPENINGS AND DAMAGED AREAS THAT OCCUR DURING DEMOLITION.
ALL PATCHING SHALL CONFORM TO THE ADJOINING WORK, MATCHING THE FINISH AND
QUALITY OF WORKMANSHIP OF THE ADJACENT MATERIALS.
10. REMOVE ALL EXISTING FINISHES AND REPAIR AND PREPARE ALL SURFACES FOR
FINISHES
11. MATERIAL HAVING SALVAGE VALUE SHALL BECOME PROPERTY OF THE OWNER ALL
OTHER MATERIAL AND DEBRIS ACCUMULATED AS A RESULT OF DEMOLITION SHALL
BECOME THE PROPERTY OF THE CONTRACTOR AND DISPOSED OF IN A LEGAL AND
PROPER MANNER.
12. FURNISH, INSTALL, AND MAINTAIN IN SAFE CONDITIONS AT ALL TIMES TEMPORARY
PROTECTION REQUIRED TO ENSURE SAFETY FOR PERSONS AND PROPERTY DURING
DEMOLITION AND REMOVAL OF WORK.
13. CONTRACTOR SHALL MINIMIZE CONSTRUCTION AND DUST WHEREVER POSSIBLE.
14. CONTRACTOR SHALL COORDINATE ANY SYSTEMS SHUT OFF FOR MECHANICAL,
ELECTRICAL, PLUMBING OR FIRE PROTECTION AT ANY TIME DURING CONSTRUCTION.
15. REMOVE EXISTING ELECTRICAL OUTLETS AND WIRING AS REQUIRED IN WALLS, FLOORS,
AND FURNISHINGS TO BE DEMOLISHED.
16. ALL WALLS, DOORS, WINDOWS, CABINETRY AND EQUIPMENT DENOTED WITH
DASHED LINES ARE TO BE REMOVED. REFER TO DEMOLITION PLAN AND
PROPOSED FLOOR PLAN FOR FURTHER CLARIFICATIONS.
17. DEMOLITION WORK SHALL BE EXECUTED IN CONFORMANCE WITH ALL CODES AND
ORDINANCES AS SET FORTH BY ALL AUTHORITIES HAVING JURISDICTION (AHJ).
18. PRIOR TO THE START OF DEMOLITION WORK GENERAL CONTRACTOR SHALL DETERMINE
THE LOCATION OF LOAD BEARING PARTITIONS AND COLUMNS AND PROVIDE
TEMPORARY SUPPORTS AS REQUIRED BY REMOVAL OR RELOCATION OF SUCH
PARTITIONS. G.C. TO ENSURE ALL TEMPORARY SUPPORTS ARE CARRIED TO SUFFICIENT
BEARING MATERIALS.
19. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL AND TEMPORARY
RELOCATION OF ALL LIFE SAFETY SYSTEMS INCLUDING FIRE/SMOKE ALARM AS
REQUIRED DURING DEMOLITION AND CONSTRUCTION PHASES.
20. REFER TO STRUCTURAL DRAWINGS FOR ALL STRUCTURAL DEMOLITION AND DETAILS.
4 4
5 5
8'-4" - FIELD VERIFY8'-4" - FIELD VERIFY
7 7
DEMOLITION PLAN LEGEND
TO REMAIN - EXISTING CMU WALL
REMOVE FRAME WALL
TO REMAIN - EXISTING WINDOW
TO REMAIN - EXISTING FRAME WALL
TO REMAIN - HINGED DOOR
TO REMOVE - HINGED DOOR
TO REMOVE - BI-PASS DOORS
DEMOLITION PLAN NOTES
FIELD VERIFY LOCATION OF EXISTING AIR HANDLER, TO BE SHIFTED
WITHIN NEW LOCATION OF BEDROOM CLOSET (LOCATION FIELD VERIFY).
REMOVE EXISTING CABINETRY, SINK, STOVE, AND REFRIGERATOR. -
PATCH AND REPAIR AS NEEDED (LOCATION FIELD VERIFY).
REMOVE EXISTING TOILET, SINK AND SHOWER/TUB AND CABINETRY:
REMOVE EXISTING SHOWER WALL TILES AND SHOWER FLOORING
TILES AND ANY ASSOCIATED PLUMBING - PATCH AND REPAIR AS
NEEDED (LOCATION FIELD VERIFY).
4 EXISTING ELECTRICAL PANEL WILL BE RELOCATED (SEE ELECTRICAL
DRAWINGS FOR LOCATION)
5 CONTRACTOR TO FIELD VERIFY PLUMBING LINES. EXISTING PLUMBING
WILL HAVE ADJUSTMENTS MADE TO ENSURE FHA COMPLIANCE.
7 EXISTING CLOSET ROD TO BE RELOCATED INTO NEW CLOSET LOCATION
SCALE:
EXISTING FIRST FLOOR PLAN - BUILDING I
3/16"=1'-0"
C FOREFRONT ARCHITECTURE & ENGINEERING LLC 2014 THIS DOCUMENT AND/OR THE DESIGN CONCEPTS EXPRESSED HEREIN ARE THE PROPERTY OF FOREFRONT ARCHITECTURE & ENGINEERING LLC AND ALL RIGHTS OF OWNERSHIP, INCLUDING COPYRIGHT OF INTELLECTUAL PROPERTY, ARE RESERVED. ANY REPRODUCTIONS, COPYING, OR USE OF THIS DOCUMENT AND/OR THE DESIGN CONCEPT WITHOUT THE WRITTEN CONSENT OF FOREFRONT ARCHITECTURE & ENGINEERING LLC IS STRICTLY PROHIBITED AND PROTECTED BY UNITED STATES AND INTERNATIONAL LAW. IF PRINTED ON 11X17 SCALE IS HALF THE SIZE NOTED.J:\City of Kissimmee\Jobs\Haven on Vine 1B\24-14065-02\Dwgs\Sheets\Architectural\A100 EXISTING AND DEMOLITION FIRST FLOOR PLAN - BUILDING I ; Plot Date: Monday, November 04, 2024 ,3:36:47 PM ; Plotted By: minelg
JO
B N
A M
E
S H
E E T N
A M
E
ISSUE - REVISION LOG
AR102538 - CA30900
H A V E N
O N
V
IN
E
P H
A S E
B W
E S T V
IN
E S
T R E E T K
IS
S
IM
M E E F L
S E A L
M A R K
D A T E
D E S C R
IP
T
IO
N
1230 Oakley Seaver Drive, Suite 100
Clermont, Florida 34711
888.850.FFAE (3323)
www.forefrontae.com
JOB # :
SHEET NUMBER :
24-14065
DATE : 11/05/2024
/3
/2
SCALE:
DEMOLITION FIRST FLOOR PLAN - BUILDING I
3/8"=1'-0"
PLAN NORTH
EXISTING WALL TO REMAIN
WALL LEGEND
2X4 WOOD STUD WALL
DOOR TAG. SEE SHEET A701 FOR
DOOR SCHEDULE
DOOR AND WINDOW LEGEND
XX
2x4 WOOD STUD
2" DRYWALL, PAINTED
T02
2x4 WOOD STUD
2" DRYWALL, PAINTED
TILE
2" DENSHIELD BD @ TILE
T01
G R A S S
UP
EXISTING
DOOR
EXISTING
DOOR
EXISTING
DOOR
EXISTING
SMOKE
ALARM
ESA
E S A
ESA
PROPOSED
SMOKE
ALARMEXISTING
SMOKE
ALARM
SA
EXISTING
SMOKE
ALARM
EXISTING
DOOR
FIRE
EXTINGUISHERE
EXISTING
SMOKE
ALARM
ESA
E S A
ESA
PROPOSED
SMOKE
ALARM EXISTING
SMOKE
ALARM
SA
EXISTING
SMOKE
ALARM
FIRE
EXTINGUISHER E
0'-0"
30'-5"
R A M P
SLOPE 1:25
0'-8 1/4"
0'-0"
17'-5"
3'-9"14'-2"3'-9"
11'-10"22'-4"
5'-0"
27'-3"
G R A S SG R A S S
G R A S S
G R A S S
G R A S S
G R A S S
NEW CONCRETE 12"
DEEP STEP TO MATCH
WIDTH OF EXISTING
SIDEWALK
0'-8 1/4"
EXISTING FIRE
EXTINGUISHER
EXISTING
DOOR
IF EXTINGUISHER WEIGHS MORE THAN 40LB
(18.14 KG)...
-TOP OF EXTINGUISHER CANNOT BE MORE THAN
3.5 FT (1.07M.) FROM THE GROUND.
- BOTTOM OF EXTINGUISHER MUST BE AT LEAST
4 IN. (102 MM.) OFF THE GROUND.
IF EXTINGUISHER WEIGHS LESS THAN 40LB (18.14
KG)...
-TOP OF EXTINGUISHER CANNOT BE MORE THAN 5
FT (1.53M) FROM THE GROUND.
-BOTTOM OF EXTINGUISHER MUST BE AT LEAST 4
IN. (102MM) OFF THE GROUND.
IN BOTH CASES, THIS INCLUDES EXTINGUISHERS
IN CABINETS, BUT IT DOES NOT INCLUDE
WHEELED EXTINGUISHERS.
C FOREFRONT ARCHITECTURE & ENGINEERING LLC 2014 THIS DOCUMENT AND/OR THE DESIGN CONCEPTS EXPRESSED HEREIN ARE THE PROPERTY OF FOREFRONT ARCHITECTURE & ENGINEERING LLC AND ALL RIGHTS OF OWNERSHIP, INCLUDING COPYRIGHT OF INTELLECTUAL PROPERTY, ARE RESERVED. ANY REPRODUCTIONS, COPYING, OR USE OF THIS DOCUMENT AND/OR THE DESIGN CONCEPT WITHOUT THE WRITTEN CONSENT OF FOREFRONT ARCHITECTURE & ENGINEERING LLC IS STRICTLY PROHIBITED AND PROTECTED BY UNITED STATES AND INTERNATIONAL LAW. IF PRINTED ON 11X17 SCALE IS HALF THE SIZE NOTED.J:\City of Kissimmee\Jobs\Haven on Vine 1B\24-14065-02\Dwgs\Sheets\Architectural\A102 PROPOSED FIRST FLOOR PLAN-FHA ; Plot Date: Monday, November 04, 2024 ,3:37:06 PM ; Plotted By: minelg
JO
B N
A M
E
S H
E E T N
A M
E
ISSUE - REVISION LOG
AR102538 - CA30900
H A V E N
O N
V
IN
E
P H
A S E
B W
E S T V
IN
E S
T R E E T K
IS
S
IM
M E E F L
S E A L
M A R K
D A T E
D E S C R
IP
T
IO
N
1230 Oakley Seaver Drive, Suite 100
Clermont, Florida 34711
888.850.FFAE (3323)
www.forefrontae.com
JOB # :
SHEET NUMBER :
24-14065
DATE : 11/05/2024
/3
/2
SCALE:
PROPOSED FIRST FLOOR PLAN - BUILDING I
3/8"=1'-0"
PLAN NORTH
G R A S S
UP
EXISTING
DOOR
FIRE
ESTINGUISHERE
FIRE
ESTINGUISHER E
S02
S01 S03
MERGE
P1 & P2
MERGE
P2 & P3
E01
W 36"
M 160
A 6
S02
S01S03
MERGE
P1 & P2
MERGE
P2 & P3
TRAVEL
PATH
44'
TRAVEL
PATH
44'
TRAVEL
PATH 2
44'
TRAVEL
PATH 1
44'
TRAVEL
PATH 3
28'
TRAVEL
PATH
28'
EXISTING FIRE
EXTINGUISHER
EXISTING
DOOR
W 36"
M 160
A 3
W 36"
M 160
A 3
INDICATES START OF LONGEST TRAVEL PATH INSIDE OF BUILDING
INDICATES END OF TRAVEL PATH OUTSIDE OF DOOR
INDICATES TRAVEL PATH NUMBER
INDICATES TRAVEL PATH DISTANCE
TRAVEL PATH, ARROWS INDICATE DIRECTION
CLEAR WIDTH OF OPENING
EGRESS USER FACTOR
INDICATES CLEAR WIDTH OF CORRIDOR IN INCHES
MERGE POINTS OF ONE OR MORE EXIT TRAVEL PATHS
FIRE EXTINGUISHER CABINET, WALL-MOUNTED
5 LB, 2A-10B:C, MULTI-PURPOSE EXTINGUISHER.
TOP OF EXTINGUISHER SHALL NOT BE MORE THAN 5' AFF
AND THE BOTTOM SHALL NOT BE LESS THAN 4" AFF
SMOKE DETECTOR, CEILING-MOUNTED
INTRUSION / BURGLAR ALARM PANEL
FIRE EXTINGUISHER CABINET, WALL-MOUNTED
5 LB, TYPE 'K' EXTINGUISHER.
TOP OF EXTINGUISHER SHALL NOT BE MORE THAN 5' AFF
AND THE BOTTOM SHALL NOT BE LESS THAN 4" AFF
COMBINATION EXIT LIGHT AND EMERGENCY LIGHT
DENOTES DIRECTION OF SIGN FACE
EXIT LIGHT-SHADED AREA DENOTES DIRECTION OF SIGN FACE
ADDITIONAL 'E' DESIGNATES EXISTING EXIT LIGHT
VISUAL SIGNALING UNIT - WALL MOUNTED
FLASHING "FIRE" LIGHT ONLY (NO AUDIO DEVICE)
FIRE ALARM ANNUNCIATOR PANEL, FLUSH MOUNTED
MANUAL PULL STATION
COMBINATION AUDIBLE/VISUAL SIGNALING
UNIT- CHIME/FLASHING "FIRE" LIGHT
FIRE ALARM CONTROL PANEL
SECURITY CAMERA
CEILING OUTLET BOX AND SMOKE DETECTOR
2 X 4 FLUORESCENT WITH BATTERY INVERTER BACK-UP
SMOKE ALARM & ANNUNCIATOR FOR DUCT-MOUNTED SMOKE
DETECTORS
LIFE SAFETY LEGEND
1. FIRE EXTINGUISHERS TO BE LOCATED A MAXIMUM OF 75 FEET FROM ANY
LOCATION.
NOTES
S -
E -
TRAVEL
PATH
80'
CORRIDOR
WIDTH XX"
MERGE
P1 0 P2
FEC
SD
BA
FEC K
SA
FAAP
FACP
F
F
F
E
EXIT LIGHTEXIT
EXIT LIGHT IN PUBLIC AREASEXIT
EMERGENCY LIGHT
EGRESS DOORWAY WIDTH IN INCHES PROVIDED
W
M A
EGRESS CAPACITY CALCULATED MAX. OCCUPANT LOAD (0.2)
ACTUAL APPORTIONED OCCUPANT LOAD CALCULATED
TO PASS THROUGH THIS OPENING
XX"
XX
XX
NOTES
GENERAL NOTES FOR LIFE SAFETY PLANS
1. OCCUPANT LOAD FACTOR IS DETERMINED PER MOST STRINGENT
REQUIREMENTS OF NFPA 101 TABLE 7.3.1.2 AND FBC TABLE 1004.5.
2. OCCUPANT LOAD IS DETERMINED PER MOST STRIGENT REQUIREMENTS OF NFPA
101 SECTION 18.1.7 AND FBC SECTION 1004. FOR BUSINESS OCCUPANCY.
3. EGRESS CAPACITY WIDTH FACTOR IS DETERMINED PER MOST STRINGENT
REQUIREMENTS OF NFPA 101 TABLE 7.3.3.1 AND FBC SECTION 1005.
4. MINIMUN CLEAR EXIT EGRESS WIDTH REQUIRED PER MOST STRINGENT
REQUIREMENTS OF NFPA 101 SECTION 7.3.4 AND FBC SECTION 1005.
5. MAXIMUN TRAVEL DISTANCE FROM "THE MOST REMOTE POINT IN A ROOM" TO
"AN EXIT ACCESS DOOR IS 300 FEET, PER MOST STRIGENT REQUIREMENTS OF
NFPA 101 SECTION 7.6 & A7.6, NFPA 101 TABLE A7.6, FBC SECTION 1016 AND
FBC TABLE 1016.1 FOR SPRINKLED BUSINESS OCCUPANCY
6. FBC 5.8.3.1 ACCESSORY OCCUPANCIES AND 508.3.1.3 SEPARATION THE SPACES
ARE SUBSIDIARY TO THE MAIN BUSINESS OCCUPANCY. OCCUPY LESS THAN 10
PERCENT OF THE OVERALL BUILDING SQUARE FOOTAGE AND THEREFORE WILL
NOT BE REQUIRED TO HAVE A 1 HOUR SEPARATION FROM THE MAIN
OCCUPANCY.
1. THE LIFE SAFETY PLANS ARE "DIAGRAMMATIC ONLY". THEIR PURPOSE IS SOLELY
TO REPRESENT THE LIFE SAFETY COMPONENTS FOR THE PROJECT (AS INCLUDED
IN THE CONSTRUCTION DOCUMENTS PREPARED BY THE ARCHITECT AND
ENGINEERS). THE CONTRACTOR SHALL USE THE CONSTRUCTION DOCUMENTS
(NOT THE LIFE SAFETY PLANS) FOR THE IMPLEMENTATION OF THE REQUIRED
LIFE SAFETY COMPONENTS INTO THE PROJECT.
2. THE CONTRACTOR SHALL ADVISE THE ARCHITECT IMMEDIATELY UPON
DISCOVERY OF ANY LIFE SAFETY COMPONENT THAT IS SHOWN ON THE LIFE
SAFETY PLANS BUT HAS NOT BEEN INCLUDED IN THE CONSTRUCTION
DOCUMENTS PREPARED BY THE ARCHITECT AND/OR ENGINEERS
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING THAT THE
REQUIRED VISIBILITY FOR EACH EXIT SIGN SHALL BE VISIBLE, WITHOUT
DIMINISHMENT IN THE DIRECTION OF TRAVEL
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR STENCILING EACH "FIRE
WALL/PARTITION/BARRIER" CLASSIFICATION IN RED LETTERS ABOVE THE FINISH
CEILING ON EACH SIDE OF ALL PARTITIONS.
FUNCTION OF SPACE
OCCUPANCY CATEGORY
SF
OCCUPANT LOAD
FACTOR
INDIVIDUAL
OCCUPANT LOAD
NAME
LIVING, DINING, BEDROOMS 490 200 GROSSAPARTMENT I-1
OCCUPANT LOAD - FIRST FLOOR - BUILDING I
TOTAL SQUARE FOOTAGE & OCCUPANT LOAD
200 GROSSAPARTMENT I-2 LIVING, DINING, BEDROOMS 490 3
980 6
C FOREFRONT ARCHITECTURE & ENGINEERING LLC 2014 THIS DOCUMENT AND/OR THE DESIGN CONCEPTS EXPRESSED HEREIN ARE THE PROPERTY OF FOREFRONT ARCHITECTURE & ENGINEERING LLC AND ALL RIGHTS OF OWNERSHIP, INCLUDING COPYRIGHT OF INTELLECTUAL PROPERTY, ARE RESERVED. ANY REPRODUCTIONS, COPYING, OR USE OF THIS DOCUMENT AND/OR THE DESIGN CONCEPT WITHOUT THE WRITTEN CONSENT OF FOREFRONT ARCHITECTURE & ENGINEERING LLC IS STRICTLY PROHIBITED AND PROTECTED BY UNITED STATES AND INTERNATIONAL LAW. IF PRINTED ON 11X17 SCALE IS HALF THE SIZE NOTED.J:\City of Kissimmee\Jobs\Haven on Vine 1B\24-14065-02\Dwgs\Sheets\Architectural\A102 PROPOSED LIFE SAFETY PLAN FIRST FLOOR ; Plot Date: Monday, November 04, 2024 ,3:37:17 PM ; Plotted By: minelg
JO
B N
A M
E
S H
E E T N
A M
E
ISSUE - REVISION LOG
AR102538 - CA30900
H A V E N
O N
V
IN
E
P H
A S E
B W
E S T V
IN
E S
T R E E T K
IS
S
IM
M E E F L
S E A L
M A R K
D A T E
D E S C R
IP
T
IO
N
1230 Oakley Seaver Drive, Suite 100
Clermont, Florida 34711
888.850.FFAE (3323)
www.forefrontae.com
JOB # :
SHEET NUMBER :
24-14065
DATE : 11/05/2024
/0
/0
SCALE:
LIFE SAFETY - FIRST FLOOR PLAN - BUILDING I
3/8"=1'-0"
PLAN NORTH
EXISTING LIGHT
FIXTURE
RELOCATED
LIGHT
FIXTURE
EXISTING LIGHT
FIXTURE
EXISTING LIGHT
FIXTURE
VP
EXISTING LIGHT
FIXTURE
RELOCATED LIGHT
FIXTURE
EXISTING LIGHT
FIXTURE
EXISTING LIGHT
FIXTURE
VP
NEW V.P. LIGHT -
REFER TO
ELECTRICAL
DRAWINGS FOR
MAKE/MODEL.
REFER TO ELECTRICAL PLAN
SHEET E201 FOR LIGHTING
SPECIFICATIONS AND
LOCATIONS
REFER TO ELECTRICAL PLAN
SHEET E201 FOR LIGHTING
SPECIFICATIONS AND
LOCATIONS
NEW LIGHT
FIXTURE - REFER
TO ELECTRICAL
DRAWINGS FOR
MAKE/MODEL.
NEW LIGHT
FIXTURE - REFER
TO ELECTRICAL
DRAWINGS FOR
MAKE/MODEL.
EXISTING
CEILING HT.
+/-7'-11"
FIELD
VERIFY
CL. HT.
EXISTING
CEILING
HEIGHT
FIELD
VERIFY
CL. HT.
EXISTING
CEILING
HEIGHT
+/-7'-11"
+/-7'-11"
NEW V.P. LIGHT
-REFER TO
ELECTRICAL
DRAWINGS FOR
MAKE/MODEL.
1. DIMENSIONS NOTED IN EACH AREA DESIGNATE CEILING
HEIGHT ABOVE FINISH FLOOR.
2. SEE PLUMBING AND ELECTRICAL DRAWINGS FOR
LOCATIONS OF LIGHT FIXTURES IN EXPOSED CEILING AREA.
3. CONTRACTOR TO COORDINATE ALL DISCIPLINES TO ENSURE
CLEARANCES FOR AL DUCTWORK, EQUIPMENT, FIXTURES,
PIPES, CONDUITS, SUSPENSION AND ACOUSTIC SYSTEMS
NECESSARY TO MAINTAIN CEILING ELEVATION NOTED
4. ALL ACOUSTICAL LAY-IN TYPE CEILING TILES ARE TO BE
HIGH HUMIDITY-RESISTANT TILES.
SYMBOL DESCRIPTION
SYMBOL DESCRIPTION
EXISTING LIGHT FIXTURE
LIGHTING TYPES
CEILING TYPES
EXISTING GYPSUM BOARD
CEILING PATCH AND REPAIR AS
REQUIRED.
NEW LIGHT FIXTURE SEE ELEC'L
PLAN E201
VP NEW V.P. FIXTURE SEE ELEC'L PLAN
E201
C FOREFRONT ARCHITECTURE & ENGINEERING LLC 2014 THIS DOCUMENT AND/OR THE DESIGN CONCEPTS EXPRESSED HEREIN ARE THE PROPERTY OF FOREFRONT ARCHITECTURE & ENGINEERING LLC AND ALL RIGHTS OF OWNERSHIP, INCLUDING COPYRIGHT OF INTELLECTUAL PROPERTY, ARE RESERVED. ANY REPRODUCTIONS, COPYING, OR USE OF THIS DOCUMENT AND/OR THE DESIGN CONCEPT WITHOUT THE WRITTEN CONSENT OF FOREFRONT ARCHITECTURE & ENGINEERING LLC IS STRICTLY PROHIBITED AND PROTECTED BY UNITED STATES AND INTERNATIONAL LAW. IF PRINTED ON 11X17 SCALE IS HALF THE SIZE NOTED.J:\City of Kissimmee\Jobs\Haven on Vine 1B\24-14065-02\Dwgs\Sheets\Architectural\A200 PROPOSED REFLECTED CEILING PLAN-FHA ; Plot Date: Monday, November 04, 2024 ,3:37:27 PM ; Plotted By: minelg
JO
B N
A M
E
S H
E E T N
A M
E
ISSUE - REVISION LOG
AR102538 - CA30900
H A V E N
O N
V
IN
E
P H
A S E
B W
E S T V
IN
E S
T R E E T K
IS
S
IM
M E E F L
S E A L
M A R K
D A T E
D E S C R
IP
T
IO
N
1230 Oakley Seaver Drive, Suite 100
Clermont, Florida 34711
888.850.FFAE (3323)
www.forefrontae.com
JOB # :
SHEET NUMBER :
24-14065
DATE : 11/05/2024
/0
/0
SCALE:
PROPOSED REFLECTED CEILING PLAN
3/8"=1'-0"
PLAN NORTH
36"x66" ROLL-SHOWER
W/ FOLD-UP SEAT
SINK
A3001
A300
4 BURNER ELECTRIC
COOK-TOP. MICROWAVE
ABOVE
REF.
SINK
SINK COOK TOP
MICROWAVE
-7
F
IE
L D
V E R
IF
Y REFRIGERATOR
EXISTING VENT. - FIELD
VERIFY FOR LOCATION
FILLER PANEL
2" 2'-7" 3" 3'-6" 31
2"
FILLER PANEL
3'-23 4" 1'-0" 3'-0" 2'-81
4"
REFERENCE KEYNOTES
NO.
1 30" WIDE MICROWAVE - (MAKE/MODEL SELECTION BY OWNER)
DESCRIPTION
+-28" TOP-FREEZER REFRIGERATOR (MAKE/MODEL SELECTION BY OWNER)
3 30" 4 BUILT-IN 4 BURNER ELECTRIC COOK-TOP (MAKE/MODEL SELECTION BY OWNER)
PARTICLE-BOARD CABINET MILLWORK WITH LAMINATE FINISH (MAKE/MODEL SELECTION
BY OWNER)
5 3"X6" FULL HEIGHT CERAMIC SUBWAY TILES (MAKE/MODEL SELECTION BY OWNER)
24" WIDE DROP-IN/UNDER-MOUNT STAINLESS STEEL SINGLE BOWL SINK AND PULL-DOWN
FAUCET (MAKE/MODEL SELECTION BY OWNER)
18" GRAB BAR ADA COMPLIANT - VERTICAL POSITION - PROVIDE REINFORCEMENT
BLOCKING IN WALLS - BOBRICK B-6806X18 OR EQUAL
8 4"X4" CERAMIC TILES (SEE FINISH LEGEND ON SHEET A400)
9 ADA COMPLIANT FOLD DOWN SHOWER SEAT - BOBRICK B-517 OR EQUAL
10 EXISTING WINDOW
11 ADA COMPLIANT WALL MOUNT HANDHELD SHOWER HEAD AND VALVE - PER PLUMBING
36" GRAB BAR ADA COMPLIANT - HORIZONTAL POSITION - PROVIDE REINFORCEMENT
BLOCKING IN WALLS - BOBRICK B-6806X36 OR EQUAL
24" GRAB BAR ADA COMPLIANT - HORIZONTAL POSITION - PROVIDE REINFORCEMENT
BLOCKING IN WALLS - BOBRICK B-6806X24 OR EQUAL
24" FLIP UP GRAB BAR ADA COMPLIANT - VERTICAL POSITION - PROVIDE REINFORCEMENT
BLOCKING IN WALLS - BOBRICK B-4998 OR EQUAL
15 36"x36" MIRROR - TO MATCH EXISTING (MAKE/MODEL SELECTION BY OWNER)
4" GRANITE BACKSPLASH - DISTINCTIVE SURFACES OF FLORIDA - NATURAL STONE -
COLOR: ASHEN WHITE
GRANITE COUNTERTOP - DISTINCTIVE SURFACES OF FLORIDA - NATURAL STONE -
COLOR: ASHEN WHITE
18 ADA COMPLIANT ELONGATED CHAIR TOILET - PER PLUMBING
19 19" ROUND DROP-IN BATHROOM SINK AND 2 LEVER HANDLE FAUCET - PER PLUMBING
20 OPTIONAL AUXILIARY ADA COMPLIANT DOOR PULL (MAKE/MODEL SELECTION BY OWNER)
C FOREFRONT ARCHITECTURE & ENGINEERING LLC 2014 THIS DOCUMENT AND/OR THE DESIGN CONCEPTS EXPRESSED HEREIN ARE THE PROPERTY OF FOREFRONT ARCHITECTURE & ENGINEERING LLC AND ALL RIGHTS OF OWNERSHIP, INCLUDING COPYRIGHT OF INTELLECTUAL PROPERTY, ARE RESERVED. ANY REPRODUCTIONS, COPYING, OR USE OF THIS DOCUMENT AND/OR THE DESIGN CONCEPT WITHOUT THE WRITTEN CONSENT OF FOREFRONT ARCHITECTURE & ENGINEERING LLC IS STRICTLY PROHIBITED AND PROTECTED BY UNITED STATES AND INTERNATIONAL LAW. IF PRINTED ON 11X17 SCALE IS HALF THE SIZE NOTED.J:\City of Kissimmee\Jobs\Haven on Vine 1B\24-14065-02\Dwgs\Sheets\Architectural\A300 PROPOSED ENLARGED AND INTERIOR ELEVATIONS - KITCHEN-BATH ; Plot Date: Monday, November 04, 2024 ,3:37:43 PM ; Plotted By: minelg
JO
B N
A M
E
S H
E E T N
A M
E
ISSUE - REVISION LOG
AR102538 - CA30900
H A V E N
O N
V
IN
E
P H
A S E
B W
E S T V
IN
E S
T R E E T K
IS
S
IM
M E E F L
S E A L
M A R K
D A T E
D E S C R
IP
T
IO
N
1230 Oakley Seaver Drive, Suite 100
Clermont, Florida 34711
888.850.FFAE (3323)
www.forefrontae.com
JOB # :
SHEET NUMBER :
24-14065
DATE : 11/05/2024
/0
/0
SCALE:
ENLARGED KITCHEN PLAN
3/4"=1'-0" SCALE:
ENLARGED BATHROOM PLAN
3/4"=1'-0"SCALE:
KITCHEN ELEVATION
3/4"=1'-0"
SCALE:
NORTH WALL - BATH RM ELEV.
3/4"=1'-0"
SCALE:
EAST WALL - BATH RM ELEV.
3/4"=1'-0"
SCALE:
SOUTH WALL - BATH RM ELEV.
3/4"=1'-0"
SCALE:
WEST WALL - BATH RM ELEV.
3/4"=1'-0"
AB
DOOR & FRAME
SEE SCHEDULE
PROVIDE THRESHOLD
REFER TO FLOOR PLAN FOR
FLOOR FINISH TYP.
SCALE:
File Name: INTERIOR DOOR THRESHOLD 3"=1'-0"
NA
INTERIOR
INTERIOR
DRYWALL
DOOR JAMB - STUD WALL
SCALE:
File Name:
3" = 1'-0"
DOOR HEAD - STUD WALL
SCALE:
File Name:
3" = 1'-0"
INTERIOR INTERIOR
WOOD FRAME
WOOD TRIM
DRYWALL
3-5/8"
-5
/8
NA
NA
METAL STUD
METAL STUD
DOOR STOP
WOOD FRAME
WOOD TRIM
DOOR STOP
3'-2"
F.F.
1ST FLOOR.
2" 2'-10" 2"
4'-4"
2" 4'-0" 2"
HM HM
1. GENERAL CONTRACTOR TO SUBMIT TYPE-WRITTEN SHOP DRAWINGS AND PRODUCT LITERATURE FOR ALL DOORS
AND HARDWARE SPECIFIED (PREPARED BY A LICENSED AND CERTIFIED CONSULTANT)
2. THE SUBCONTRACTORS WILL INSTALL ALL DOORS, FRAMES, HARDWARE, LOCK SETS, AND ENTRANCE DOORS.
3. G.C. TO VERIFY OPENING DIMENSIONS IN FIELD PRIOR TO FABRICATION AND INSTALLATION.
4. SEE STOREFRONT ELEVATIONS AND NOTICES OF ACCEPTANCE FOR TEMPERED GLASS LOCATIONS.
5. ALL STOREFRONT WINDOWS AND DOORS ARE REQUIRED TO BE TESTED IN ACCORDANCE W/ ANSI/AMMA/NWWDA
101/1S2 STANDARDS AND BEAR AN AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURER, PERFORMANCE
CHARACTERISTICS AND APPROVED PRODUCT TESTING ENTITY.
6. ALL STOREFRONT WINDOWS AND DOORS SHALL BE ANCHORED PER NOTICE OF ACCEPTANCE AND PUBLISHED
MANUFACTURERS RECOMMENDATIONS TO ACHIEVE THE DESIGN PRESSURE SPECIFIED.
7. ALL STOREFRONT WINDOWS AND DOORS SHALL BE ANCHORED AS PER APPLICABLE CODE - ANY STOREFRONT
WINDOWS OR DOORS WITH A BUCK THICKNESS LESS THAN 1-1/2" SHALL BE ANCHORED THROUGH THE JAMB INTO THE
ADJACENT STRUCTURAL SUBSTRATE.
8. STOREFRONT MULLIONS AND ADJACENT DOOR ASSEMBLIES ARE REQUIRED TO BE TESTED OR ENGINEERED TO
TRANSFER MIN 1.5 TIMES THE DESIGNED LOADS TO THE ROUGH OPENING SUBSTRATE (OR AS PER CODE.
9. PROVIDE INFORMATION SIGN ON INTERIOR PUSH SIDE OF EXIT DOORS @ 52"H IN 1" HIGH RED VINYL LETTERS T0 READ
" THIS EXIT TO REMAIN UNLOCKED AT ALL TIMES THE BUILDING IS OCCUPIED.
1. ADJUST ALL CLOSERS TO A 5 LB. MAX. OPENING FORCE
2. ALL LOCK AND PASSAGE SETS TO BE SCHLAGE GRADE OR BETTER - SUBMIT OTHERS FOR APPROVAL - ALL LOCKS
SHALL BE REKEYABLE
3. DOOR EGRESS/PANIC SYSTEMS MUST BE IN COMPLIANCE WITH SPECIAL EGRESS CONTROL DEVICES LISTED IN LOCAL
CODES
4. SUBMIT DETAILED HARDWARE SCHEDULE FOR ARCHITECT AND/OR OWNER REVIEW PRIOR PURCHASE AND
INSTALLATION
5. ALL DOORS AND HARDWARE TO COMPLY WITH ADA AND CODE OF FEDERAL REGULATION, UTILIZING A LEVER LATCH
OR LOCKSET
6. ALL DOORS AND HARDWARE SHALL COMPLY WITH N.F.P.A. 101-5-2.1.5
HARDWARE SET #1 (SINGLE DOOR)
(1) LEVER TYPE SINGLE CYLINDER KEYED - BRAND SCHLAGE -MODEL J54MAR626-
HARDWARE SET #2 (BATHROOM)
(1) LEVER TYPE PRIVACY DOOR - BRAND SCHLAGE -MODEL J40MAR626-
(1 PACK) BUTT HINGES- HARNEY HARDWARE - MODEL HHFBB191NRP32D
(1 PACK) BUTT HINGES- HARNEY HARDWARE - MODEL HHFBB191NRP32D
HARDWARE SCHEDULE
DOOR AND FRAME SCHEDULE
MARK
WD HGT THK
SIZE
MATL GLAZING
WD HGT
LOUVER
DOOR
MATL EL
HEAD JAMB SILL
DETAIL
FRAME
FIRE
RATING
LABEL SET
NO
KEYSIDE
RM NO
HARDWARE
NOTES
APT. I-1 AND APT. I-2 ROOM FINISHES SCHEDULE
ROOM NAME
AREA MAT.
FLOORS
N S E W
WALL MATERIAL
HGT. MATL
CEILINGS
NOTES
LIVING ROOM
KITCHEN-DINING
BATHROOM
CORRIDOR
BEDROOM #1
BEDROOM #2
190.13 SF
120.85 SF
54.75 SF
26.84 SF
125.30 SF
93.42 SF
FF1
FF1
FF2
FF1
BF1/WF1 BF1/WF1 ±7'-11" CF1
FINISHES LEGEND
BF1 WOODEN BASEBOARD - REAL WOODS - WHITE - RWBA - 03
(9/16"X5 1/4") OR EQUAL
WF1 PAINTED GYPSUM - COLOR AND STYLE BY OWNER
FF1 LUXURY VINYL PLANK FLOORING - 48"X9" LIFEPROOF - COLOR/FINISH:
STERLING OAK - THICKNESS: 22 MIL
CF1 PAINTED GYPSUM - COLOR AND STYLE BY OWNER
BF1/WF1 BF1/WF1
±7'-11"
±7'-00"
±7'-11"
±7'-11"
±7'-11"
BF1/WF1 BF1/WF1 BF1/WF1
FF1
FF1
WF2 CERAMIC TILE - 4"X4" DALTILE: COLOR WHEEL CLASSIC - COLOR CODE:
0190 ARCTIC WHITE - FINISH: GLOSSY - SHADE VARIATION: V1: LOW OR
EQUAL / WITH 4"X4" BULLNOSE TRIM (COLOR AND STYLE TO MATCH)
WF3 1'-6" HEIGHT OF BACK SPLASH CERAMIC TILE - COLOR AND STYLE BY OWNER
FF2 CERAMIC TILE - 12"X12" DALTILE: CORE FUNDAMENTALS - COLOR CODE: CG05
EVEREST WHITE - FINISH: MATTE - SHADE VARIATION: V3: HIGH OR EQUAL.
BF1/WF1 BF1/WF1/WF2WF2 BF1/WF1/WF2
BF1/WF1 BF1/WF1 BF1/WF1 BF1/WF1
BF1/WF1 BF1/WF1 BF1/WF1 BF1/WF1
BF1/WF1 BF1/WF1 BF1/WF1 BF1/WF1
CF1
CF1
CF1
CF1
CF1
WF1/WF3
NOTE: ALL CHOSEN MATERIALS TO COMPLY WITH ASTM E84 CLASS B FLAME
SPREAD INDEX RATING MINIMUM. 6
2'-10"
WD
F.F.
1ST FLOOR.
3'-9"
WD
A400
A400
A400
A400
A400
A400
C FOREFRONT ARCHITECTURE & ENGINEERING LLC 2014 THIS DOCUMENT AND/OR THE DESIGN CONCEPTS EXPRESSED HEREIN ARE THE PROPERTY OF FOREFRONT ARCHITECTURE & ENGINEERING LLC AND ALL RIGHTS OF OWNERSHIP, INCLUDING COPYRIGHT OF INTELLECTUAL PROPERTY, ARE RESERVED. ANY REPRODUCTIONS, COPYING, OR USE OF THIS DOCUMENT AND/OR THE DESIGN CONCEPT WITHOUT THE WRITTEN CONSENT OF FOREFRONT ARCHITECTURE & ENGINEERING LLC IS STRICTLY PROHIBITED AND PROTECTED BY UNITED STATES AND INTERNATIONAL LAW.