2023 MBS Modular-Full Dwg Set-SMES.pdf

PDF 2 MB Posted

Attached to
Scouters Mountain Elementary School Modular Classroom Installation Project, ITB-002-2023
Solicitation number
S-P03012-00006604
Issued by
Clackamas County, Hebo CDP, Oregon

About this file

This document contains detailed architectural and engineering plans for a 28' x 64' modular classroom building to be installed at the Scouters Mountain Elementary School in Happy Valley, Oregon. The project is a joint effort between the North Clackamas School District and Modern Building Systems, Inc. The plans cover the full scope of the modular classroom, including the floor plan, exterior and interior elevations, electrical, HVAC, and plumbing systems. The plans were prepared and submitted for approval under the applicable Oregon building codes.

The related state and local contract opportunity is for the general site preparation and modification work, including waterlines, sewer, storm drainage, grading, irrigation seeding, fencing, and electrical and plumbing utilities. Modern Building Systems will be contracted separately to deliver and install the pre-engineered modular building and associated decking. The project is located in Clackamas County, Oregon.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DESIGN PROFESSIONAL

MICHAEL C. LEWIS P.E.

MODERN BUILDING SYSTEMS, INC.

9493 PORTER RD. SE AUMSVILLE, OR 97325

503-749-4949 mlewis@modernbuildingsystems.com

PLEASE REVIEW AND COMMENT ON THESE

DOCUMENTS. PLEASE RETURN APPROVED SET

OR COMMENTS BY

FAILURE TO RESPOND BY THIS DATE COULD

CAUSE DELAYS, INCREASED COSTS, INABILITY

TO INCORPORATE YOUR CHANGES OR ALL

OF THE ABOVE

DATE

BY

APPROVED

CUSTOMER APPROVAL

APPROVED EXCEPT AS NOTED

REVISE AS NOTED AND RESUBMIT

4/14/23

PRELIM

IN

ARY

NOT F

OR

SUBMIT

TAL

JOB#

SHEET #

DATE

SHEET

PROJ.

ADDRESS DRW

TELEPHONE: (503) 749-4949 FAX: (503) 749-4950

P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325

CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com

MODERN BUILDING SYSTEMS, INC. 2023

MODERN BUILDING SYSTEMS, INC.

REUSE OF DOCUMENTS THIS

DOCUMENT AND THE IDEAS AND

DESIGNS INCORPORATED HEREIN

ARE THE PROPERTY OF MODERN

BUILDING SYSTEMS INC. AND ARE

NOT TO BE USED IN WHOLE OR IN

PART FOR ANY OTHER USE OR

PROJECT WITHOUT WRITTEN

AUTHORIZATION.

2023-DS-18

A 0.0

4/3/2023 PRELIM

COVER SHEET

10811 SE 172nd AVE, HAPPY VALLEY, OR 97086

28' x 64' MODULAR CLASSROOM

BJ

NORTH CLACKAMAS SD

N. CLACKAMAS SD

28' x 64' MODULAR CLASSROOM

SHEET INDEX

Sht.

No. Sheet Name

Current Rev.

Rev Issued By

A 0.0 COVER SHEET

A 0.1 GENERAL NOTES

A 0.3 ABBREVIATIONS & SYMBOLS

A 0.4 SITE LAYOUT

A 1.0 FLOOR PLAN

A 2.0 EXTERIOR ELEVATIONS

A 2.1 EXTERIOR ELEVATIONS

A 3.0 FINISH NOTES

A 3.1 SCHEDULES

A 3.2 DATA SCHEDULES

A 4.0 INTERIOR ELEVATIONS

A 4.1 INTERIOR ELEVATIONS & DETAILS

A 5.0 DETAILS

A 5.1 ADA MOUNTING DETAILS

E 0.1 ELECTRICAL LEGEND & NOTES

E 1.0 ELECTRICAL PLAN

E 2.0 LIGHTING PLAN

E 3.0 ELEC. PANELS & LOAD CALCS.

M 0.1 HVAC NOTES & LEGEND

P 0.1 PLUMBING NOTES

REV. DESCRIPTION DATE BY

GENERAL NOTES

1. THE TERM IBC SHALL APPLY TO THE CURRENT EDITION OF

THE INTERNATIONAL BUILDING CODE (IBC) AS AMENDED BY

THE STATES OF OREGON AND WASHINGTON. FOR PROJECTS

IN ALL OTHER STATES IT SHALL APPLY TO THE CURRENT

EDITION OF THE UBC OR IBC AS ADOPTED BY THAT STATE.

2. ALL CONTROLS AND HARDWARE SHALL BE ACCESSIBLE TO

PERSONS WITH DISABILITIES.

3. WHERE REQUIRED, PORTABLE FIRE EXTINGUISHERS SHALL

BE INSTALLED IN ACCORDANCE WITH OFC/IFC SECTION 906

4. PER WAC 296-150F-0605, TOILET FACILITIES IN AN ADJACENT

FACILITY SHALL BE NOTED ON THE PLAN SUBMITTAL AND

THAT THE REQUIREMENTS OF IBC CHAPTER 29, SECTION

2902.1 AND SECTION 2902.2 OF THE STATE BUILDING CODE

MUST BE VERIFIED BY THE LOCAL JURISDICTION BUILDING

OFFICIAL AND SHOWN ON THE NLEA.

PER OAR 918-674-0015, REQUIRED TOILET FACILITIES MAY BE

LOCATED IN AN ADJACENT FACILITY PER IBC CHAPTER 29,

SECTION 2902.3.3 AND THE LOCAL JURISDICTION BUILDING

OFFICIAL SHALL VERIFY THAT ADEQUATE FACILITIES ARE

AVAILABLE BASED ON THE OVERALL OCCUPANT LOAD OF THE

ENTIRE COMPLEX.

5. IF APPLICABLE, FIRE ALARM SYSTEM TO BE FIELD INSTALLED

(BY OTHERS) PER OSSC/IBC SECTION 907.2.3, GROUP E. SEE

ELECTRICAL PLAN FOR DEVICE LOCATIONS. FIRE ALARM

INSPECTION AND APPROVAL PER LOCAL AUTHORITY HAVING

JURISDICTION.

6. IF APPLICABLE, FIRE SAFETY AND EVACUATION PLANS SHALL

BE PROVIDED BY OWNER PRIOR TO CERTIFICATE OF

OCCUPANCY PER OFC/IFC SECTION 403

7. AN ACCESSIBLE ROUTE SHALL BE PROVIDED TO THE

BUILDING AREA AS REQUIRED IN OSSC/IBC SECTION 1104

8. WHERE FLOOR LIVE LOAD EXCEEDS 50 PSF, A DURABLE SIGN

SHALL BE CONSPICUOUSLY POSTED BY THE OWNER IN THE

PART OF THE BUILDING WHERE THIS INCREASED FLOOR LIVE

LOAD OCCURS PER OSSC/IBC SECTION 106.1

SHEAR WALL TYPE IS BEARING WALL SYSTEM USING LIGHT-

FRAME (WOOD) WALLS SHEATHED WITH WOOD STRUCTURAL

PANELS. ALL EXTERIOR WALL PIERS WITH MAXIMUM ASPECT

RATIO OF 2:1 ARE CONSIDERED AS ENGINEERED SHEAR WALLS

GENERAL:

CONSTRUCTION TYPE

OCCUPANCY GROUP (IBC CH. 3)

OCCUPANCY LOAD (IBC TABLE 1004.5)

DISTANCE TO PROPERTY LINE

OR ASSUMED PROPERTY LINE

ELECTRICAL:

ELECTRICAL SERVICE LOAD

MECHANICAL:

VENTILATION OCC. LOAD (IMC TABLE 403.3.1.1)

CLIMATE ZONE

HEATING

AIR-CONDITIONING

PLUMBING:

PLUMBING OCC. LOAD (IBC TABLE 1004.5, 2902.1)

QUANTITY OF PLUMBING FIXTURES

STRUCTURAL:

ROOF SNOW LOAD

FLOOR LIVE LOAD

WIND LOAD

VB (NON-SPRINKLERED)

E (ELEMENTARY, KINDERGARDEN - FIFTH GRADE)

72 OCCUPANTS, SEE SUMMARY ON SHEET A 3.2

FRONT: 10' MIN.

REAR: 10' MIN.

LEFT: 10' MIN.

RIGHT: 10' MIN.

200A / 120/208V / 3 PH.

52.2 kVA

56 OCCUPANTS, SEE SUMMARY ON SHEET M 0.1

4C

SPV/HP

YES

72 (36 MALE/36 FEMALE)

Lambda = 1.0 Vult = 140 MPH (Vasd = 108 MPH) 3 SECOND GUST - EXP. B

BEARING WALL SYSTEM: SS = 1.500, Fa = 1.200

SDS = 1.000, (PER ASCE 7-16 SEC. 12.8.1.3) RISK CATEGORY II

DESIGN CRITERIA

SEISMIC

25 PSF (+5 PSF SOLAR READY)

50 PSF

Ie = 1.0, SEISMIC DESIGN CATEGORY D, SITE CLASS D

THIS SET OF PLANS PREPARED AND SUBMITTED FOR APPROVAL UNDER THE FOLLOWING CODES:

BUILDING

MECHANICAL

FIRE

PLUMBING

ELECTRICAL

ENERGY

ACCESSIBILITY

OREGON

2022 OSSC

2022 OMSC

2022 OFC

2021 OPSC

2021 OESC

2021 OEESC/ASHRAE 90.1-2019

ICC A117.1-2017

EXTERIOR WALL RATING (IBC TABLE 602) FIRE SEPARATION DISTANCE 10' OR GREATER, NO RATING REQUIRED

REQUIRED SPECIAL INSPECTIONS STEEL COLUMN WELDING, SUSPENDED CEILING W/ BERC CLIPS

PRELIM

IN

ARY

NOT F

OR

SUBMIT

TAL

JOB#

SHEET #

DATE

SHEET

PROJ.

ADDRESS DRW

TELEPHONE: (503) 749-4949 FAX: (503) 749-4950

P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325

CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com

MODERN BUILDING SYSTEMS, INC. 2023

MODERN BUILDING SYSTEMS, INC.

REUSE OF DOCUMENTS THIS

DOCUMENT AND THE IDEAS AND

DESIGNS INCORPORATED HEREIN

ARE THE PROPERTY OF MODERN

BUILDING SYSTEMS INC. AND ARE

NOT TO BE USED IN WHOLE OR IN

PART FOR ANY OTHER USE OR

PROJECT WITHOUT WRITTEN

AUTHORIZATION.

2023-DS-18

A 0.1

4/3/2023 PRELIM

GENERAL NOTES

10811 SE 172nd AVE, HAPPY VALLEY, OR 97086

28' x 64' MODULAR CLASSROOM

BJ

NORTH CLACKAMAS SD

ABBREVIATIONS

A.B.

ADJ.

A.F.F.

AL

BA

BD.

BLK.

B.O.

BOT.

BRCH

BV.

CDR.

CJ

CL

CLG.

CLR.

CMU

C.O.

CONC.

CONT.

CPT

DBL.

DF

DIA.

DIM.

DS

DTL

DW

EA.

ELEC.

ELEV.

EQUIP.

EXIST.

EXT.

E.W.

F.C.

FD

FDN

F.E.

F.E.C.

FGL

FLR.

FIN.

F.O.FIN.

F.O.FRM.

F.R.T.

FS

ANCHOR BOLT

ADJUSTABLE

ABOVE FINISH FLOOR

ALUMINUM

BRONZE ANODIZED

BOARD

BLOCK

BOTTOM OF

BOTTOM

BIRCH

BOTTOM VENT

CEDAR

CONTROL JOINT

CENTERLINE

CEILING

CLEAR

CONCRETE MASONRY UNIT

CLEAN OUT

CONCRETE

CONTINUOUS

CARPET

DOUBLE

DRINKING FOUNTAIN

DIAMETER

DIMENSION

DOWNSPOUT

DETAIL

DISHWASHER

EACH

ELECTRICAL

ELEVATIONS

EQUIPMENT

EXISTING

EXTERIOR

EACH WAY

FIBER CEMENT

FLOOR DRAIN

FOUNDATION

FIRE EXTINGUISHER

FIRE EXTINGUISHER CABINET

FIBERGLASS

FLOOR

FINISH

FACE OF FINISH

FACE OF FRAMING

FIRE RETARDANT TREATED

FLOOR SINK

GA.

GALV.

GLB

GYP.

HB

HC

HF

HM

HSS

INFO.

INSUL.

INT.

KD

L.

LAV

LH

LHOS

LVL

MAX.

MECH.

MFR.

MIN.

MISC.

MOD

MPL

MTL.

MV

N.I.C.

NOM.

NRW

NTS

OBS

O.C.

OFCI

OFOI

OPP.

O.S.B.

PD

PF

PLAM

PLCS

PLYWD

PNT

P.T.

REFRIG.

REQ'D

GAUGE

GALVANIZED

GLULAM BEAM

GYPSUM

HOSE BIB

HOLLOW CORE

HEM FIR

HOLLOW METAL

HOLLOW STRUCTURAL SECTION

INFORMATION

INSULATION

INTERIOR

KNOCK DOWN

LONG

LAVATORY

LEFT HAND

LEFT HAND OUT SWING

LAMINATED VENEER LUMBER

MAXIMUM

MECHANICAL

MANUFACTURER

MINIMUM

MISCELLANEOUS

MODULE

MAPLE

METAL

MIXING VALVE

NOT IN CONTRACT

NOMINAL

NARROW (LITE)

NOT TO SCALE

OBSCURE

ON CENTER

OWNER FURNISHED CONTRACTOR INSTALLED

OWNER FURNISHED OWNER INSTALLED

OPPOSITE

ORIENTED STRAND BOARD

PUNCH & DIMPLE

PREFINISHED

PLASTIC LAMINATE

PLACES

PLYWOOD

PAINT

PRESSURE TREATED

REFRIGERATOR

REQUIRED

RH

RHOS

R.O.

SC

SF

SH

SHT.

SHTG.

SIM.

SIMP.

SQ.

S.S.

STN.

STRUCT.

TIM.

TMP

T.O.

TTP

TYP.

U.N.O.

UR

VCT

V.C.

VWS

W/

WC

WD.

WH

RIGHT HAND

RIGHT HAND OUT SWING

ROUGH OPENING

SOLID CORE

STOREFRONT

SINGLE HUNG

SHEET

SHEATHING

SIMILAR

SIMPSON

SQUARE

STAINLESS STEEL

STAIN

STRUCTURAL

TIMELY

TEMPERED SAFETY GLAZING

TOP OF

TAPE, TEXTURE & PAINT

TYPICAL

UNLESS NOTED OTHERWISE

URINAL

VINYL COMPOSITION TILE

VINYL COATED

VINYL WRAP SURROUND

WITH

WATER CLOSET

WOOD

WATER HEATER

TYPICAL SYMBOLS LEGEND

MOD A

A101

SIM

A101

1 Ref

R e f

1 Ref

R e f

Name Elevation

A101

SIM

A101

SIM

1t

ELEVATION BUBBLE

SECTION BUBBLE

DETAIL BUBBLE

DETAIL CALLOUT

GRID BUBBLE

ELEVATION LEVEL

MODULE TAG

DOOR TAG

WINDOW TAG

REVISION TAG

CENTERLINE

1i WALL TAG

1 KEYNOTE

NORTH ARROW

PRELIM

IN

ARY

NOT F

OR

SUBMIT

TAL

JOB#

SHEET #

DATE

SHEET

PROJ.

ADDRESS DRW

TELEPHONE: (503) 749-4949 FAX: (503) 749-4950

P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325

CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com

MODERN BUILDING SYSTEMS, INC. 2023

MODERN BUILDING SYSTEMS, INC.

REUSE OF DOCUMENTS THIS

DOCUMENT AND THE IDEAS AND

DESIGNS INCORPORATED HEREIN

ARE THE PROPERTY OF MODERN

BUILDING SYSTEMS INC. AND ARE

NOT TO BE USED IN WHOLE OR IN

PART FOR ANY OTHER USE OR

PROJECT WITHOUT WRITTEN

AUTHORIZATION.

2023-DS-18

A 0.3

4/3/2023 PRELIM

ABBREVIATIONS & SYMBOLS

10811 SE 172nd AVE, HAPPY VALLEY, OR 97086

28' x 64' MODULAR CLASSROOM

BJ

ELECTRICAL PANELE

MECH. UNITM

SYMBOL LEGEND

MOD A

2023-18-1A

TRUCK END

MOD C

2023-18-1C

MOD B

2023-18-1B

MOD D

2023-18-1D

M O

D A

3-

-2

A

M O

D C

3-

8-

C

M O

D B

3-

-2

B

M O

D D

3-

8-

D

EXISTING BUILDING

M

M

EM

M

E

CONC. SIDEW

ALK

MODS TO BE SET BY ROLLING

GEAR OR TRANS-LIFT

RAMPS AND LANDINGS TO BE

INSTALLED BY MBS

E X

IS

T

IN

G B

LD

G

/4 T O

E X

IS

T

IN

G B

LD

G

/4 T O

DISTANCE TO PROPERTY

LINE GREATER THAN 10'-0"

DISTANCE TO

PROPERTY

LINE GREATER

THAN 10'-0"

DISTANCE TO

PROPERTY

LINE GREATER

THAN 10'-0"

12' - 10"

PRELIM

IN

ARY

NOT F

OR

SUBMIT

TAL

JOB#

SHEET #

DATE

SHEET

PROJ.

ADDRESS DRW

TELEPHONE: (503) 749-4949 FAX: (503) 749-4950

P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325

CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com

MODERN BUILDING SYSTEMS, INC. 2023

MODERN BUILDING SYSTEMS, INC.

REUSE OF DOCUMENTS THIS

DOCUMENT AND THE IDEAS AND

DESIGNS INCORPORATED HEREIN

ARE THE PROPERTY OF MODERN

BUILDING SYSTEMS INC. AND ARE

NOT TO BE USED IN WHOLE OR IN

PART FOR ANY OTHER USE OR

PROJECT WITHOUT WRITTEN

AUTHORIZATION.

2023-DS-18

A 0.4

4/3/2023 PRELIM

SITE LAYOUT

10811 SE 172nd AVE, HAPPY VALLEY, OR 97086

28' x 64' MODULAR CLASSROOM

BJ

NORTH CLACKAMAS SD

1/16" = 1'-0"

SITE LAYOUT

REV. DESCRIPTION DATE BY

NOTE: BUILDINGS ARE CONSIDERED

TO BE ONE STRUCTURE, PER 2022

OSSC SECTION 705.3 EXCEPTION 1. NO

FIRE SEPARATION REQUIRED

BETWEEN BUILDINGS.

ALLOWABLE AREA: 9,500 SQFT

ACTUAL AREA PER BUILDING: 1,771 SQFT

TOTAL AREA: 3,542 SQFT

1 4

A

C

B

CLASSROOM A

64' - 0"

MECH .

UNIT A

MECH .

UNIT B

MOD B

MOD A

A A A A

ELEC.

PANEL

B B

CLASSROOM B

8'x4'

MARKER

BOARD

8'x4'

MARKER

BOARD

6'x4'

MARKER

BOARD

6'x4'

MARKER

BOARD

CLR.

ZONE

6' x 5'

WALK-OFF

MAT 8'x4' TACK

BOARD

8'x4' TACK

BOARD

4' - 0" 6' - 0" 2' - 0" 6' - 0" 5' - 0" 8' - 11 5/8"

7/8"

8' - 11 5/8" 5' - 0" 6' - 0" 2' - 0" 6' - 0" 4' - 0"

4' - 0" 6' - 0" 8' - 1" 6' - 0" 3' - 5" 4' - 5 5/8"

6' x 5'

WALK-OFF

MAT

3 4

MOD D

MOD C

A 4.1

A 4.0

3 2

31' - 11 5/8" 31' - 11 5/8"

4' - 5 5/8" 3' - 5" 6' - 0" 8' - 1" 6' - 0" 4' - 0"

A 4.1

1 SIM

S

IM

A 4.0

1 SIM

S

IM

S

IM

RESTROOM A RESTROOM B

T Y

P

T Y

P

/2

T Y

P

/2

/2

" 2x6 FURRING

WALL - TYP.

BACKING PROVIDED

FOR MOUNTING TV -

SEE 3/A 4.0 FOR SIZING

23' - 0"23' - 0"

TO F.O. FIN.

12" MIN. CLR.

PRELIM

IN

ARY

NOT F

OR

SUBMIT

TAL

JOB#

SHEET #

DATE

SHEET

PROJ.

ADDRESS DRW

TELEPHONE: (503) 749-4949 FAX: (503) 749-4950

P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325

CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com

MODERN BUILDING SYSTEMS, INC. 2023

MODERN BUILDING SYSTEMS, INC.

REUSE OF DOCUMENTS THIS

DOCUMENT AND THE IDEAS AND

DESIGNS INCORPORATED HEREIN

ARE THE PROPERTY OF MODERN

BUILDING SYSTEMS INC. AND ARE

NOT TO BE USED IN WHOLE OR IN

PART FOR ANY OTHER USE OR

PROJECT WITHOUT WRITTEN

AUTHORIZATION.

2023-DS-18

A 1.0

4/3/2023 PRELIM

FLOOR PLAN

10811 SE 172nd AVE, HAPPY VALLEY, OR 97086

28' x 64' MODULAR CLASSROOM

BJ

NORTH CLACKAMAS SD

3/16" = 1'-0"

FLOOR PLAN

Fin-Floor 0' - 0"

Roof / Plate 8' - 1 1/8"

0 - Grade -2' - 6"

AC B

CORNER BATT - TYP.

S H

IP

P

IN

G

H E

IG

H

T

/4

Fin-Floor 0' - 0"

Roof / Plate 8' - 1 1/8"

0 - Grade -2' - 6"

1 42

P.T. 2 x 8 x 16'-0" UNDER DOORS

IN PLACE OF OFFSET RIM

A A

1 2

A A

24" X 16" SIGN

ON EA. MECH. UNIT

PRELIM

IN

ARY

NOT F

OR

SUBMIT

TAL

JOB#

SHEET #

DATE

SHEET

PROJ.

ADDRESS DRW

TELEPHONE: (503) 749-4949 FAX: (503) 749-4950

P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325

CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com

MODERN BUILDING SYSTEMS, INC. 2023

MODERN BUILDING SYSTEMS, INC.

REUSE OF DOCUMENTS THIS

DOCUMENT AND THE IDEAS AND

DESIGNS INCORPORATED HEREIN

ARE THE PROPERTY OF MODERN

BUILDING SYSTEMS INC. AND ARE

NOT TO BE USED IN WHOLE OR IN

PART FOR ANY OTHER USE OR

PROJECT WITHOUT WRITTEN

AUTHORIZATION.

2023-DS-18

A 2.0

4/3/2023 PRELIM

EXTERIOR ELEVATIONS

10811 SE 172nd AVE, HAPPY VALLEY, OR 97086

28' x 64' MODULAR CLASSROOM

BJ

NORTH CLACKAMAS SD

3/16" = 1'-0"

RIGHT SIDE ELEVATION

3/16" = 1'-0"

FRONT ELEVATION

Fin-Floor 0' - 0"

Roof / Plate 8' - 1 1/8"

0 - Grade -2' - 6"

A CB

MOD BATT W/ (2) ROWS

OF 8d AT 6" O.C. - TYP.

Fin-Floor 0' - 0"

Roof / Plate 8' - 1 1/8"

0 - Grade -2' - 6"

14 2

WINDOW TRIM

B B

3 EXHAUST FAN

ROOF CAP

B B

PRELIM

IN

ARY

NOT F

OR

SUBMIT

TAL

JOB#

SHEET #

DATE

SHEET

PROJ.

ADDRESS DRW

TELEPHONE: (503) 749-4949 FAX: (503) 749-4950

P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325

CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com

MODERN BUILDING SYSTEMS, INC. 2023

MODERN BUILDING SYSTEMS, INC.

REUSE OF DOCUMENTS THIS

DOCUMENT AND THE IDEAS AND

DESIGNS INCORPORATED HEREIN

ARE THE PROPERTY OF MODERN

BUILDING SYSTEMS INC. AND ARE

NOT TO BE USED IN WHOLE OR IN

PART FOR ANY OTHER USE OR

PROJECT WITHOUT WRITTEN

AUTHORIZATION.

2023-DS-18

A 2.1

4/3/2023 PRELIM

EXTERIOR ELEVATIONS

10811 SE 172nd AVE, HAPPY VALLEY, OR 97086

28' x 64' MODULAR CLASSROOM

BJ

NORTH CLACKAMAS SD

3/16" = 1'-0"

LEFT SIDE ELEVATION

3/16" = 1'-0"

REAR ELEVATION

RIM JOIST TO FLOOR JOIST

JOIST TO JOIST

BLOCKING

STUDS TO PLATES - END NAIL

STUDS TO PLATES - END NAIL

BLOCKING

JAMB STUD TO 4x HEADER JAMB STUD TO 2x HEADER

STUD TO STUD (CRIPPLE, ETC.)

UPPER TOP PLATE TO LOWER

TOP PLATE

BOTTOM PLATE TO FLOOR

RIM JOIST TO RAFTER

RIM JOIST TO TRUSS

RAFTER TO RAFTER

BLOCKING

2 x 4 LEDGER 2x BRACE TO RAFTER

3 PER JOIST

2 ROWS AT 12" O.C.

2 EACH END

2 EACH END AT 2 x 4 3 EACH END AT 2 x 6

2 EACH END

MIN. 4 EACH END

MIN. 2 EACH END

8" O.C.

2 EACH SIDE OF STUD

2 EACH SIDE OF STUD

3 PER RAFTER

MIN. 2 PER TRUSS

2 ROWS AT 12" O.C.

2 EACH END

2 ROWS AT 6" O.C.

4 AT RAFTER

CONNECTION NO. / SPACING

F L

O O

R W

A L

L R

O O

F

MINIMUM NUMBER OF NAILS FOR WOOD MEMBERS

(EXCEPT AS NOTED ON DRAWINGS)

NOTES:

1. ALL FASTENERS ARE 12d (.131), USE HDG FASTENERS OR

EQUAL AT P.T. MEMBERS

2. SUBSTITUTION OF CONNECTORS SPECIFIED IN THIS DRAWING

SET IS ALLOWED FOR EQUAL OR BETTER CONNECTOR

PRODUCTS

STANDARD SHEATHING FASTENING - U.N.O.

SPACING TYPE

MIN.

LENGTH

FLOOR SHEATHING (UNBLOCKED)

23/32" CDX OR O.S.B. OR

STURDI - FLOOR T&G

6" EDGE

8" FIELD

8d (.113)

RING-SHANK

2-3/8"

FLOOR UNDERLAYMENT (GLUE AND STAGGER JOINTS)

1/4" CCP 8" EDGE

8" FIELD

18 GA. STAPLE

MIN. 1/4" CROWN

SIDING (ALL EDGES SUPPORTED)

15/32" T1-11 6" EDGE

12" FIELD

8d (.113)

GALVANIZED

ROOF SHEATHING (UNBLOCKED)

7/16" O.S.B. 6" EDGE

8" FIELD

15 GA. STAPLE

MIN. 7/16" CROWN

1"

2-3/8"

2"

FROM ESR-1539 JULY 2022

FASTENING/SCHEDULEFLOOR CONSTRUCTION

FINISH: SHEET VINYL AT RESTROOM, CARPET THRU-OUT,

WALK-OFF MAT WHERE SHOWN ON FLOOR PLAN

BASE: 6" VINYL AT RESTROOM, 4" VINYL AT BALANCE

UNDERLAYMENT: 1/4" CCP AT SHEET VINYL

SUBFLOOR: 23/32" APA RATED SHEATHING (24)

(ACTS AS 1 PERM MAX. VAPOR BARRIER)

(ACTS AS AIR BARRIER)

JOISTS: 2 x 8 DF #2 AT 16" O.C., DBL. 2 x 8 AT ENDS

RIM JOISTS: MURPHY LVL 3100 Fb - 2.0E, 1-1/2" W x 7-1/4" D

(ESR-1387 AND ESR-2913)

OFFSET RIMS: 2 x 4 DF (U.N.O.)

INSULATION: R-30 U (FIBERGLASS BATTS)

BOTTOM CLOSURE: FS-25

EXTERIOR WALL CONSTRUCTION

PLATE HEIGHT: 8'-1 1/8"

SIDING: 15/32" T1-11 (16) W/ 8" VERT. GROOVES, 7/16" O.S.B.

SHEATING AT GRIDS '2' & '3'

SHEATHING: NONE

STUDS: 2 x 6 DF STUD GRADE AT 16" O.C. W/ BLDG

WRAP AT EXTERIOR (ACTS AS A WATER RESISTIVE

BARRIER) (ACTS AS AIR BARRIER)

INSULATION: R-21 U (FIBERGLASS BATTS)

HEADERS TO BE (2) 2x W/ MIN. R-10 INSULATION

BETWEEN. SEE DOOR AND WINDOW SCHEDULE FOR SIZE.

INTERIOR FINISH: 5/8" V.C. GYPSUM BOARD

(ACTS AS 1 PERM. MAX. VAPOR BARRIER)

F.R.P. OVER WATER REISTANT GYPSUM BOARD AT

RESTROOMS

SKIRT: MATCH SIDING

INTERIOR WALL CONSTRUCTION

PLATE HEIGHT: 8'-1 1/8"

STUDS: 2 x 4 HF STUD GRADE AT 16" O.C. (U.N.O.)

INTERIOR FINISH: 5/8" V.C. GYPSUM BOARD

(ACTS AS 1 PERM. MAX. VAPOR BARRIER)

F.R.P. OVER WATER REISTANT GYPSUM BOARD AT

RESTROOMS

CEILING NOTES

CEILING HEIGHT: NOMINAL 8'-0" (U.N.O.), 7'-11" AT

RESTROOM

CEILING: SUSPENDED T-GRID W/ ACOUSTIC TILE

(REF: ESR-1308)

INSTALL ARMSTRONG 7301 HEAVY DUTY MAIN W/ 7/8"

ANGLE & BERC CLIPS

SPECIAL INSPECTION REQUIRED IN SEISMIC DESIGN

CATEGORIES C, D, E & F

ROOF CONSTRUCTION

ROOFING: FIBERGLASS COMP. SHINGLES OVER (2) LAYERS

SYNTHETIC FELT (MIN. CLASS B), (6) STAPLES

ICE AND WATER SHIELD OR MOP MIN. 2'-0" INSIDE WALL

LINE AT EAVES AND GABLE

SHEATHING: 7/16" O.S.B. (24/16) AND CEDAR TEXTURE PANEL

(NO GROOVES FACE DOWN AT EXPOSED OVERHANGS)

(ACTS AS AIR BARRIER)

FRAMING: 2 x 10 DF #2 AT 24" O.C.

BEAMS: MURPHY LVL 3100 Fb 2.0E, 1-1/2" W x 24" D

(ESR-1387 AND ESR-2913)

INSULATION: R-38 (CELLULOSE) W/ BOTTOM CLOSURE

(ACTS AS 1 PERM MAX. VAPOR BARRIER)

(ACTS AS AIR BARRIER)

OVERHANG: 6"

ROOF PITCH: 2 IN 12

EXTERIOR NOTES

CORNER BATTS: 1 x 4

FASCIA: 1 x 6

BARGE: 1 x 6

WINDOW/DOOR TRIM: 1 x 4

GUTTERS: 4" K-LINE (PREFINISHED)

DOWNSPOUTS: 2" x 3" RECT. (PREFINISHED)

PRELIM

IN

ARY

NOT F

OR

SUBMIT

TAL

JOB#

SHEET #

DATE

SHEET

PROJ.

ADDRESS DRW

TELEPHONE: (503) 749-4949 FAX: (503) 749-4950

P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325

CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com

MODERN BUILDING SYSTEMS, INC. 2023

MODERN BUILDING SYSTEMS, INC.

REUSE OF DOCUMENTS THIS

DOCUMENT AND THE IDEAS AND

DESIGNS INCORPORATED HEREIN

ARE THE PROPERTY OF MODERN

BUILDING SYSTEMS INC. AND ARE

NOT TO BE USED IN WHOLE OR IN

PART FOR ANY OTHER USE OR

PROJECT WITHOUT WRITTEN

AUTHORIZATION.

2023-DS-18

A 3.0

4/3/2023 PRELIM

FINISH NOTES

10811 SE 172nd AVE, HAPPY VALLEY, OR 97086

28' x 64' MODULAR CLASSROOM

BJ

HARDWARE SCHEDULE

GROUP #1

HINGES: (3) BUTT, HAGER BB1279 NRP,

4.5" x 4.5", US26D

LEVERSET: (CLASSROOM)

SCHLAGE ND97PD RHO, 626

STRIKE: ANSI

CLOSER: LCN 4040XP

WEATHER-STRIP: PEMKO S88

DOOR SWEEP: PEMKO 345AV 36"

RAINDRIP: PEMKO 346C-40

ADA THRESHOLD: PEMKO 176A

DOORS: 1,2

GROUP #2

DOORS: 3,4

GROUP #3

DOORS: DOORS:

GROUP #4

HINGES: (3) BUTT, HAGER RCB1541

3.5" x 3.5", US32D

LEVERSET: (PRIVACY)

SCHLAGE AL40S SAT, 626

INDICATOR: PRIVACY SIGN

STRIKE: FULL LIP

WALL STOP: IVES WS406CCV/

WS407CCV 630

PRELIM

IN

ARY

NOT F

OR

SUBMIT

TAL

JOB#

SHEET #

DATE

SHEET

PROJ.

ADDRESS DRW

TELEPHONE: (503) 749-4949 FAX: (503) 749-4950

P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325

CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com

MODERN BUILDING SYSTEMS, INC. 2023

MODERN BUILDING SYSTEMS, INC.

REUSE OF DOCUMENTS THIS

DOCUMENT AND THE IDEAS AND

DESIGNS INCORPORATED HEREIN

ARE THE PROPERTY OF MODERN

BUILDING SYSTEMS INC. AND ARE

NOT TO BE USED IN WHOLE OR IN

PART FOR ANY OTHER USE OR

PROJECT WITHOUT WRITTEN

AUTHORIZATION.

2023-DS-18

A 3.1

4/3/2023 PRELIM

SCHEDULES

10811 SE 172nd AVE, HAPPY VALLEY, OR 97086

28' x 64' MODULAR CLASSROOM

BJ

NORTH CLACKAMAS SD

WINDOW SCHEDULE

Mark Count Width Height Type Frame Glass SHGC U-VAL VT Air Leakage Ext. Trim Int. Trim Window Header Top of R.O. Comments

A 4 6' - 0" 4' - 0" XO VINYL 0.22 0.25 0.52 .18 CFM/SF 1x4 WD/VWS (2) 2 x 8 DF #2 6' - 9"

B 4 6' - 0" 4' - 0" XO VINYL DUAL / LOW E / ARGON 0.22 0.25 0.52 .18 CFM/SF 1x4 WD/VWS (2) 2 x 8 DF #2 6' - 9"

NOTES:

1. CAULK AND SEAL ALL EXTERIOR DOORS

2. ALL EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT (U.N.O.)

3. ALL DOOR LEADS 4-1/2" U.N.O.

4. ALL DOORS TO HAVE A OPENING FORCE NOT EXCEED 5 POUNDS

5. DOOR SURFACES WITHIN 10" OF THE FLOOR MEASURED VERTICALLY, SHALL BE SMOOTH SURFACE ON THE PUSH SIDE EXTENDING

THE FULL WIDTH OF THE DOOR PER ICC A117.1 SECTION 404.2.9

NOTES:

1. CAULK AND SEAL ALL EXTERIOR WINDOWS

DOOR SCHEDULE

Mark Width Height Thickness Door Swing Core Lite Size Lite

Glass Face Door Finish

Frame Type

Frame Finish Throat

R.O.

Type

Hdw Group Door Header U-Value S.H.G.C. V.T. Remarks

1 3' - 0" 6' - 8" 1 3/4" LHOS HM HALF TMP MTL PT HM PT 6 3/4" G 1 (2) 2 x 8 DF #2 0.5 0.23 0.37

2 3' - 0" 6' - 8" 1 3/4" LHOS HM HALF TMP MTL PT HM PT 6 3/4" G 1 (2) 2 x 8 DF #2 0.5 0.23 0.37

3 3' - 0" 6' - 8" 1 3/4" LH SC - - WD WD WD WD 4 3/4" 1 2

4 3' - 0" 6' - 8" 1 3/4" RH SC - - WD WD WD WD 4 3/4" 1 2

DOOR ROUGH OPENING SCHEDULE

A

R.O. WIDTH

R.O. HEIGHT

EXTERIOR DOORS

B

C

D

E1

E2

F

G

INTERIOR DOORS

NOTE: ALL TRIMMER HEIGHTS = R.O. CALL SIZE MINUS 1-1/2"

METAL DOORS W/ HOLLOW METAL FRAME (WELDED)

CALL SIZE + 4-1/2"

CALL SIZE + 2-1/8"

R.O. WIDTH

R.O. HEIGHT

DBL. METAL DOORS W/ HOLLOW METAL FRAME (WELDED)

CALL SIZE + 4-1/2"

CALL SIZE + 2-1/8"

R.O. WIDTH

R.O. HEIGHT

STOREFRONT DOOR

CALL SIZE + 4-1/2"

CALL SIZE + 2-1/8"

R.O. WIDTH

R.O. HEIGHT

TIMELY SPLIT MEDIA DOOR

CALL SIZE + 1-1/4"

CALL SIZE + 1"

R.O. WIDTH

R.O. HEIGHT

METAL DOOR W/ WOOD FRAME (PEASE AND STANLEY) (INSWING)

CALL SIZE + 2"

CALL SIZE + 2"

R.O. WIDTH

R.O. HEIGHT

METAL DOOR W/ WOOD FRAME (PEASE AND STANLEY) (OUTSWING)

CALL SIZE + 2"

CALL SIZE + 1-9/16"

R.O. WIDTH

R.O. HEIGHT

METAL DOOR W/ METAL FRAME (FAST-FRAME)

CALL SIZE + 1-1/4"

CALL SIZE + 1"

R.O. WIDTH

R.O. HEIGHT

METAL DOOR W/ HOLLOW METAL FRAME (KNOCK-DOWN)

CALL SIZE + 2"

CALL SIZE + 1"

R.O. WIDTH

R.O. HEIGHT

HOLLOW / SOLID WOOD DOOR W/ WOOD FRAME

CALL SIZE + 2"

CALL SIZE + 2-1/8"

R.O. WIDTH

R.O. HEIGHT

TIMELY FRAME

CALL SIZE + 1-1/4"

CALL SIZE + 1"

R.O. WIDTH

R.O. HEIGHT

POCKET DOOR

2x CALL SIZE + 2"

CALL SIZE + 4"

R.O. WIDTH

R.O. HEIGHT

BI-PASS DOOR

CALL SIZE

CALL SIZE + 2-1/8"

R.O. WIDTH

R.O. HEIGHT

BI-FOLD DOOR

CALL SIZE + 2"

CALL SIZE + 1 1/4"

PRELIM

IN

ARY

NOT F

OR

SUBMIT

TAL

JOB#

SHEET #

DATE

SHEET

PROJ.

ADDRESS DRW

TELEPHONE: (503) 749-4949 FAX: (503) 749-4950

P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325

CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com

MODERN BUILDING SYSTEMS, INC. 2023

MODERN BUILDING SYSTEMS, INC.

REUSE OF DOCUMENTS THIS

DOCUMENT AND THE IDEAS AND

DESIGNS INCORPORATED HEREIN

ARE THE PROPERTY OF MODERN

BUILDING SYSTEMS INC. AND ARE

NOT TO BE USED IN WHOLE OR IN

PART FOR ANY OTHER USE OR

PROJECT WITHOUT WRITTEN

AUTHORIZATION.

2023-DS-18

A 3.2

4/3/2023 PRELIM

DATA SCHEDULES

10811 SE 172nd AVE, HAPPY VALLEY, OR 97086

28' x 64' MODULAR CLASSROOM

BJ

NORTH CLACKAMAS SD

AREA SCHEDULE (Gross Building)

AREA TYPE NO. MODS AREA

Gross Building Area 2 1771 SF

ROOF SCHEDULE

DESCRIPTION AREA

ROOF 1889 SF

WALL SCHEDULE

DESCRIPTION LENGTH

EXTERIOR 2x6 181' - 5"

EXTERIOR 2x, SKIRTWALL 183' - 0"

INTERIOR 2x4 87' - 7"

INTERIOR 2x6 25' - 9"

OCCUPANT LOAD SCHEDULE

FUNCTION OF SPACE Area

LOAD

FACTOR

OCCUPANT

LOAD

CLASSROOM A 714 SF 20 36

CLASSROOM B 714 SF 20 36

Total 72

8'x4' TACK

BOARD

13' - 6 3/8"

3' - 6" 3' - 6" 10' - 0 3/8"

A 4.1

B

8'x4"

MARKER

BOARD

6'x4'

MARKER

BOARD

6' - 11 3/8" 12' - 8" 7' - 0 3/8"

RETURN GRILLE

BACKING PROVIDED

FOR 70" TV

ELEC. PANEL

1' - 0 1/2" 1' - 11 1/2"

1' - 6" 3' - 6"

15" BARSINK

(FULL OFFSET)

8 GAL. WH

PROVIDE 24" CLR. ACCESS

TO WATER HEATER

A 4.1

INTERIOR ELEVATION NOTES

1. DIMENSIONS TO FLOOR, WALLS AND CEILING ARE

TO FACE OF FINISH (U.N.O.)

2. PROVIDE WOOD BLOCKING FOR ALL ACCESSORIES

MOUNTED IN GYPSUM BOARD PARTITIONS.

MAINTAIN INTEGRITY OF FIRE RATING WHERE

ACCESSORIES ARE IN RATED WALLS.

3. SEE DETAILS ON SHEET A5.1 FOR ADA RESTROOM

ACCESSORIES AND MOUNTING HEIGHTS.

A 4.1

3' - 6" 3' - 6" 3' - 6" 3' - 6"

PRELIM

IN

ARY

NOT F

OR

SUBMIT

TAL

JOB#

SHEET #

DATE

SHEET

PROJ.

ADDRESS DRW

TELEPHONE: (503) 749-4949 FAX: (503) 749-4950

P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325

CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com

MODERN BUILDING SYSTEMS, INC. 2023

MODERN BUILDING SYSTEMS, INC.

REUSE OF DOCUMENTS THIS

DOCUMENT AND THE IDEAS AND

DESIGNS INCORPORATED HEREIN

ARE THE PROPERTY OF MODERN

BUILDING SYSTEMS INC. AND ARE

NOT TO BE USED IN WHOLE OR IN

PART FOR ANY OTHER USE OR

PROJECT WITHOUT WRITTEN

AUTHORIZATION.

2023-DS-18

A 4.0

4/3/2023 PRELIM

INTERIOR ELEVATIONS

10811 SE 172nd AVE, HAPPY VALLEY, OR 97086

28' x 64' MODULAR CLASSROOM

BJ

NORTH CLACKAMAS SD

REV. DESCRIPTION DATE BY

1/4" = 1'-0"

CLASSROOM - FRONT WALL

1/4" = 1'-0"

CLASSROOM - LEFT WALL

1/4" = 1'-0"

CLASSROOM - RIGHT WALL

PROVIDE WOOD WALL BLOCKING AS NEEDED FOR

ALL ACCESSORIES, PARTITIONS, PLUMBING

FIXTURES, EQUIPMENT AND DOOR WALL STOPS

4' - 9" MIN.

T.P. HOLDER

GRAB

BARS

4'-0" HIGH FRP

WAINSCOT OVER

WATER RESISTANT

GYPSUM BOARD -

TYP.

4' - 4" MIN.

PROVIDE PROTECTIVE

INSUL. AT WATER

SUPPLY AND

DRAINPIPES - TYP

18" x 36"

MIRROR

M

IN

M A

X

INTERIOR ELEVATION NOTES

1. DIMENSIONS TO FLOOR, WALLS AND CEILING ARE

TO FACE OF FINISH (U.N.O.)

2. PROVIDE WOOD BLOCKING FOR ALL ACCESSORIES

MOUNTED IN GYPSUM BOARD PARTITIONS.

MAINTAIN INTEGRITY OF FIRE RATING WHERE

ACCESSORIES ARE IN RATED WALLS.

3. SEE DETAILS ON SHEET A5.1 FOR ADA RESTROOM

ACCESSORIES AND MOUNTING HEIGHTS.

1' - 2" 1' - 2" 1' - 2"

1' - 9" 1' - 9"

3' - 6"

FIXED SHELF

(2) COAT

HOOKS PER

CUBBY

1' - 0"

3" 9"

TOE KICK

FRONT SIDE

1' - 2" 1' - 2" 1' - 2"

3' - 6"

(2) COAT

HOOKS PER

CUBBY

1' - 0"

3" 9"

TOE KICK

FRONT SIDE

4' - 0"

(2) COMPARTMENTS

W/ FIXED SHELVES

CLOSET W/ HANGER

ROD AT 48" A.F.F.

(4) ADJUSTABLE

SHELVES

CAM LOCK EACH DOOR

AT 30" A.F.F. W/ (2)

KEYS EACH.

2'-0

4'-0"

"DOOR PULL EACH

DOOR, TOP OF PULL

AT 36" A.F.F.

DOOR PULL EACH

DOOR, TOP OF PULL

AT 74" A.F.F.

CAM LOCK EACH DOOR

AT 76" A.F.F. W/ (2)

KEYS EACH.

PRELIM

IN

ARY

NOT F

OR

SUBMIT

TAL

JOB#

SHEET #

DATE

SHEET

PROJ.

ADDRESS DRW

TELEPHONE: (503) 749-4949 FAX: (503) 749-4950

P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325

CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com

MODERN BUILDING SYSTEMS, INC. 2023

MODERN BUILDING SYSTEMS, INC.

REUSE OF DOCUMENTS THIS

DOCUMENT AND THE IDEAS AND

DESIGNS INCORPORATED HEREIN

ARE THE PROPERTY OF MODERN

BUILDING SYSTEMS INC. AND ARE

NOT TO BE USED IN WHOLE OR IN

PART FOR ANY OTHER USE OR

PROJECT WITHOUT WRITTEN

AUTHORIZATION.

2023-DS-18

A 4.1

4/3/2023 PRELIM

INTERIOR ELEVATIONS & DETAILS

10811 SE 172nd AVE, HAPPY VALLEY, OR 97086

28' x 64' MODULAR CLASSROOM

BJ

NORTH CLACKAMAS SD

REV. DESCRIPTION DATE BY

1/4" = 1'-0"

RESTROOM - BACK WALL

1/4" = 1'-0"

RESTROOM - RIGHT WALL

PROVIDE WOOD WALL BLOCKING AS NEEDED FOR ALL ACCESSORIES,

PARTITIONS, PLUMBING FIXTURES, EQUIPMENT AND DOOR WALL STOPS

3/8" = 1'-0"

CASEWORK - 6 CUBBIES

3/8" = 1'-0"

CASEWORK - 3 CUBBIES

1/4" = 1'-0"

TEACHER CABINET

SIDING

STUDS

INT. FINISH

DOOR FRAME

(6-3/4" THROAT)

SIDINGINT. FINISH

HEADER

JAMB HEAD

DOOR FRAME

(6-3/4" THROAT)

PAN FLASHING

& FLASHING

THRESHOLD SET

IN SEALANT

DOOR FRAME

(6-3/4" THROAT)

THRESHOLD

'Z' METAL

P.T. 2 x 8 RIM

SIDING

WINDOW TRIM

STUDS

INT. FINISH

WINDOW TRIM

SIDING

WINDOW

INT. FINISH

HEADER

JAMB HEAD SILL

WINDOW

SILL

INT.

FINISH

WINDOW

WINDOW TRIM

SIDING

WOOD SILL

PRELIM

IN

ARY

NOT F

OR

SUBMIT

TAL

JOB#

SHEET #

DATE

SHEET

PROJ.

ADDRESS DRW

TELEPHONE: (503) 749-4949 FAX: (503) 749-4950

P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325

CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com

MODERN BUILDING SYSTEMS, INC. 2023

MODERN BUILDING SYSTEMS, INC.

REUSE OF DOCUMENTS THIS

DOCUMENT AND THE IDEAS AND

DESIGNS INCORPORATED HEREIN

ARE THE PROPERTY OF MODERN

BUILDING SYSTEMS INC. AND ARE

NOT TO BE USED IN WHOLE OR IN

PART FOR ANY OTHER USE OR

PROJECT WITHOUT WRITTEN

AUTHORIZATION.

2023-DS-18

A 5.0

4/3/2023 PRELIM

DETAILS

10811 SE 172nd AVE, HAPPY VALLEY, OR 97086

28' x 64' MODULAR CLASSROOM

BJ

NORTH CLACKAMAS SD

1 1/2" = 1'-0"

EXTERIOR DOOR DETAILS

1 1/2" = 1'-0"

WINDOW DETAILS

PAPER TOWEL

DISPENSER

SURFACE-MOUNTED

MIRROR

SURFACE-

MOUNTED

TOILET SEAT

COVER

DISPENSER

SURFACE

MOUNTED

SOAP

DISPENSER

RESTROOM

DOOR HOOK

A

E

F

G

H

TOILET PAPER HOLDER SIDE & VERTICAL GRAB BAR BACK GRAB BAR

B

C C

D

SCHEDULE OF ACCESSORIES

I.D. ITEMS

A PAPER TOWEL DISPENSER

B TOILET PAPER HOLDER

C HORIZONTAL GRAB BAR

D VERTICAL GRAB BAR

E SOAP DISPENSER

F MIRROR

G TOILET SEAT COVER DISPENSER (N.I.C.)

H HOOK (N.I.C.)

I SHOWER SEAT (N.I.C.)

BACK GRAB BAR/SEAT SIDE GRAB BAR

C C

D

I

1 1/4" TO

2" NOM.

DIAMETER

WALL

GRAB BAR SECTION

PLAN VIEW

NOTE:

1. DIMENSIONS TO FLOOR AND WALLS ARE

TO FACE OF FINISH (U.N.O.)

2. NOT ALL ACCESSORIES MAY BE

PRESENT IN THIS PARTICULAR

BUILDING.

T O

R E

F L

E C

T

IV

E S

U R

F A

C E

CONTROLS

M

IN

/2

M

IN

42" MAX.

MIN.

24"

T .O

B

A R

M

IN

12"

MIN.

42"

39"-41"

54" MIN.

T .O

B

A R

MIN.

12"

MIN.

24"

36" MIN.

S E

A T

M A

X

A D

A S

T A

L L

M A

X

R E

G U

L A

R

M A

X A

D A

M

IN

MIN.

17"

19" MAX.

M

IN

48" MIN.

*NOTE: IF A MINIMUM 9 INCHES HEIGHT

OF TOE CLEARANCE IS PROVIDED, A

MAXIMUM OF 6 INCHES OF THE 48

INCHES OF CLEAR FLOOR SPACE

REQUIRED AT THE FIXTURE MAY

EXTEND INTO THE TOE SPACE.

KNEE CLEARANCE TOE CLEARANCE*

SIDE VIEW

LAVATORY KNEE CLEARANCE

M

IN

M

IN

M A

X

6" MAX.8" MIN.

MIN.

17"

T .O

B

A R

18"

4" MAX.

M

IN

15" MAX.

M

IN

M A

X

1 1/2"

PRELIM

IN

ARY

NOT F

OR

SUBMIT

TAL

JOB#

SHEET #

DATE

SHEET

PROJ.

ADDRESS DRW

TELEPHONE: (503) 749-4949 FAX: (503) 749-4950

P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325

CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com

MODERN BUILDING SYSTEMS, INC. 2023

MODERN BUILDING SYSTEMS, INC.

REUSE OF DOCUMENTS THIS

DOCUMENT AND THE IDEAS AND

DESIGNS INCORPORATED HEREIN

ARE THE PROPERTY OF MODERN

BUILDING SYSTEMS INC. AND ARE

NOT TO BE USED IN WHOLE OR IN

PART FOR ANY OTHER USE OR

PROJECT WITHOUT WRITTEN

AUTHORIZATION.

2023-DS-18

A 5.1

4/3/2023 PRELIM

ADA MOUNTING DETAILS

10811 SE 172nd AVE, HAPPY VALLEY, OR 97086

28' x 64' MODULAR CLASSROOM

BJ

NORTH CLACKAMAS SD

REV. DESCRIPTION DATE BY

3/8" = 1'-0"

ADA - MOUNTING HEIGHTS

ELECTRICAL SYMBOLS LEGEND

DUPLEX RECEPTACLE +17" A.F.F. (U.N.O.)

GFCI = GROUND FAULT CIRCUIT INTERRUPTER

WP = IN USE WEATHERPROOF COVER

WR = WATER RESISTANT RECEPTACLE

TR = TAMPER RESISTANT

THERMOSTAT

PHONE/DATA BOX - 3/4" CONDUIT UP (RACEWAY ONLY)

CLOCK RECEPTACLE (120V)

DISCONNECT

AUDIO / VISUAL FIRE ALARM (RACEWAY ONLY)

MANUAL PULL STATION (RACEWAY ONLY)

VISUAL ALARM

T

C

F

M

V

SYMBOL DESCRIPTION

HEIGHT

℄ (U.N.O)

+17"

+48" TOP

+17"

+86"

+45"

CEILING

+88"

4PLEX RECEPTACLE +17" A.F.F. (U.N.O.)

GFCI = GROUND FAULT CIRCUIT INTERRUPTER

WP = IN USE WEATHERPROOF COVER

WR = WATER RESISTANT RECEPTACLE

+17"

LIGHTING SYMBOLS LEGEND

OCCUPANCY SENSOR

SINGLE POLE SWITCH

OS

SYMBOL DESCRIPTION

HEIGHT

℄ (U.N.O)

CEILING

CEILING

+48" TOP

2' x 4' LED LAY-IN FIXTURE - NON-nLIGHT

EXTERIOR WALL MOUNT LIGHT FIXTURE

PC = PHOTOCELL

WP = WEATHERPROOF

+86"

OCCUPANCY SWITCH SENSOR: - W/ MANUAL ONOS +48" TOP

ELECTRICAL NOTES

1. CONDUIT SHALL BE ELECTRICAL METALLIC TUBING AND METAL

CLAD CABLE

2. EXTERIOR RECEPTACLES SHALL BE WEATHER RESISTANT TYPE

W/ IN USE WEATHERPROOF COVER

3.. BUILDING SERVICE SHALL BE SERVED BY ONLY ONE SERVICE

OR FEEDER PER NEC 225.30 AND 230.2

4. SERVICE OR FEEDER DISCONNECT SHALL BE INSTALLED PER

NEC 230.70. FOR BUILDINGS IN THE STATE OF WASHINGTON

SERVICE OR FEEDER DISCONNECT SHALL BE INSTALLED PER

WAC 296-46B-230

5. PERMANENT MEANS OF LOCKING OUT DISCONNECT TO

MECHANICAL UNIT(S) SHALL BE PROVIDED PER NEC 424.19

6. PERMANENT MEANS OF LOCKING OUT DISCONNECT TO

WATER HEATER(S) SHALL BE PROVIDED PER NEC 422.31(B)

7. GASKET ALL EXTERIOR WALL BOX PLATE COVERS

8. PER NEC 110.26D, ILLUMINATION FOR PANEL BOARDS, SWITCH-

BOARDS, AND SERVICE EQUIPMENT SHALL NOT BE CONTROLLED

BY AUTOMATIC MEANS ONLY. A MANUAL MEANS TO BYPASS THE

AUTOMATIC CONTROL IS REQUIRED.

9. PER NEC 406.9(B)(1) 15 AND 20 AMP RECEPTACLES INSTALLED IN

WET LOCATION SHALL HAVE AN ENCLOSURE THAT WEATHER-

PROOF WHETHER OR NOT THE ATTACHMENT PLUG CAP IS

INSERTED. AN OUTLET BOX HOOD INSTALLED FOR THIS

PURPOSE SHALL BE LISTED AND SHALL BE IDENTIFIED AS EXTRA

DUTY. RECEPTACLES SHALL BE LISTED AS WEATHER-RESISTANT

TYPE.

10. PER NEC 110.26, WORKING SPACE FOR EQUIPMENT OPERATING

AT 600 VOLTS, NOMINAL, OR LESS TO GROUND AND LIKELY TO

REQUIRE EXAMINATION, ADJUSTMENT, SERVICING, OR

MAINTENANCE WHILE ENERGIZED SHALL COMPLY WITH THE

DIMENSIONS OF 110.26(A)(1), (A)(2), AND (A)(3)

11. PER NFPA 72, NEC 760 AND WAC 296-46B-760 DEVICE AND

JUNCTION BOXES FOR FIRE ALARM SYSTEMS OTHER THAN

SURFACE RACEWAY TYPE MUST BE SUBSTANTIALLY RED IN

COLOR BOTH INSIDE AND OUTSIDE. POWER LIMITED FIRE

PROTECTIVE SIGNALING CIRCUIT CONDUCTORS MUST BE

DURABLY AND PLAINLY MARKED IN OR ON JUNCTION BOXES OR

OTHER ENCLOSURES TO INDICATE THAT IT IS POWER LIMITED

FIRE PROTECTIVE SIGNALING CIRCUIT.

12. PER NEC 110.22 AND WAC 296-46B-110-022 IDENTIFICATION

PLATES ON DISCONNECTING MEANS ARE TO SHOW DESIGNATION

OF CIRCUIT SOURCE PANEL BOARD THAT SUPPLIES DISCONNECT

AND IDENTIFY WHAT IT IS DISCONNECTING. MUST BE AN

IDENTIFICATION PLATE

13. PER NEC 406.3E, ALL NONLOCKING TYPE, 125 VA, 15 AMP, AND 20

AMP RECEPTACLES THAT ARE CONTROLLED BY AN AUTOMATIC

CONTROL DEVICE, OR THAT INCORPORATE CONTROL FEATURES

THAT REMOVE POWER FROM THE OULET FOR THE PURPOSE OF

ENERGY MANAGEMENT OR BUILDING AUTOMATION, SHALL BE

MARKED WITH THE SYMBOL SHOWN IN FIGURE 406.3E AND

LOCATED ON THE CONTROLLED RECEPTACLE OUTLET WHERE

VISIBLE AFTER INSTALLATION

14. FIRE ALARM POWER SOURCE AND BRANCH CIRCUITS TO COMPLY

WITH NEC 760.41(A) (B). THE FIRE ALARM CIRCUIT DISCONNECT

SHALL BE PERMITTED TO BE SECURED IN THE "ON" POSITION. THE

CIRCUIT DISCONNECTING MEANS SHALL HAVE RED IDENTIFICATION,

SHALL BE ACCESSIBLE ONLY TO QUALIFIED PERSONNEL, AND SHALL

BE IDENTIFIED AS "FIRE ALARM CIRCUIT".

1. CONTROLLED RECEPTACLES ARE NOT REQUIRED PER OEESC E301.3,b EXCEPTION #3C, AS EXCEPTIONS TO ASHRAE 8.4.2

2. OCCUPANCY SENSOR(S) IN EACH ROOM WILL BE WIRED TO CONTROL ALL LIGHT FIXTURES IN THAT ROOM.

3. LIGHT WIRING AS SHOWN IS FOR GENERAL CONTROL CLARIFICATION ONLY. ACTUAL WIRING FOR CONTROLS (I.E.:

SWITCHES, OCCUPANCY SENSORS AND DAYLIGHT SENSORS) SHALL BE PER CONTROL MANUFACTURER'S SPECIFICATIONS AND AS NECESSARY TO MEET THE CODE REQUIREMENTS FOR EACH CONTROL AND THE LIGHT

FIXTURES CONNECTED TO IT.

4. DAYLIGHT RESPONSIVE CONTROLS ARE NOT REQUIRED IN ZONES WITH LESS THAN 150 WATTS IN GENERAL PRIMARY SIDELIGHTING AREAS. DAYLIGHT ZONES INCLUDING BOTH PRIMARY AND SECONDARY SIDELIGHTED AREA LESS THAN 300 WATTS ARE NOT REQUIRED. WHEN REQUIRED, SIDELIGHTING AREAS SHALL BE CONTROLLED BY PHOTOCONTROLS; PER ASHRAE 9.4.1.1(e)

5. BUILDING FACADE LIGHTING OTHER THAN ENTRY DOORS, SHALL HAVE CONTROLS PER ASHRAE 9.4.1.4(b) TO AUTOMATICALLY SHUT OFF FACADE LIGHTING BETWEEN MIDNIGHT OR BUSINESS CLOSING, WHICHEVER IS LATER, AND 6

A.M. OR BUSINESS OPENING, WHICHEVER COMES FIRST.

LIGHTING PLAN NOTES

PRELIM

IN

ARY

NOT F

OR

SUBMIT

TAL

JOB#

SHEET #

DATE

SHEET

PROJ.

ADDRESS DRW

TELEPHONE: (503) 749-4949 FAX: (503) 749-4950

P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325

CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com

MODERN BUILDING SYSTEMS, INC. 2023

MODERN BUILDING SYSTEMS, INC.

REUSE OF DOCUMENTS THIS

DOCUMENT AND THE IDEAS AND

DESIGNS INCORPORATED HEREIN

ARE THE PROPERTY OF MODERN

BUILDING SYSTEMS INC. AND ARE

NOT TO BE USED IN WHOLE OR IN

PART FOR ANY OTHER USE OR

PROJECT WITHOUT WRITTEN

AUTHORIZATION.

2023-DS-18

E 0.1

4/3/2023 PRELIM

ELECTRICAL LEGEND & NOTES

10811 SE 172nd AVE, HAPPY VALLEY, OR 97086

28' x 64' MODULAR CLASSROOM

BJ

M

F

T T

C C

CLG. CLG.CLG. CLG.

M

C O

C O

J

CLG.

J

F F

F F

CLG.

J

CLG.

J

1 4

A

C

B

CLASSROOM A

A9 A5

A5

A5

A5

A9

A2,4 A10,12

A6,8 A14,16

A7

A7GFCI/WP/WR

GFCI/WP/WR

CLASSROOM B

A5 A7

V

CLG.

V

CLG.

A5

8'x4' TACK

BOARD

8'x4' TACK

BOARD

8'x4"

MARKER

BOARD

6'x4'

MARKER

BOARD

6'x4'

MARKER

BOARD

8'x4"

MARKER

BOARD

A5 A7

A7

A7 +42"

+42" +42"

+42"

MECH

UNIT A

MECH

UNIT B

RESTROOM A RESTROOM B

PANEL A

120/240V 3

PHASE

8 GAL

WH

A11

A13

MARK J-BOX

COVER AS

FIRE ALARM

A15A15

PROVIDE 1"

CONDUIT STUB-

OUT FROM

PANEL FOR

FUTURE SOLAR

ELECTRIC

GFCI

+42"

GFCI

+42"

+42"+42"

A5 A7

+42"

+42"

+42"

+42"

PRELIM

IN

ARY

NOT F

OR

SUBMIT

TAL

JOB#

SHEET #

DATE

SHEET

PROJ.

ADDRESS DRW

TELEPHONE: (503) 749-4949 FAX: (503) 749-4950

P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325

CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com

MODERN BUILDING SYSTEMS, INC. 2023

MODERN BUILDING SYSTEMS, INC.

REUSE OF DOCUMENTS THIS

DOCUMENT AND THE IDEAS AND

DESIGNS INCORPORATED HEREIN

ARE THE PROPERTY OF MODERN

BUILDING SYSTEMS INC. AND ARE

NOT TO BE USED IN WHOLE OR IN

PART FOR ANY OTHER USE OR

PROJECT WITHOUT WRITTEN

AUTHORIZATION.

2023-DS-18

E 1.0

4/3/2023 PRELIM

ELECTRICAL PLAN

10811 SE 172nd AVE, HAPPY VALLEY, OR 97086

28' x 64' MODULAR CLASSROOM

BJ

NORTH CLACKAMAS SD

3/16" = 1'-0"

ELECTRICAL PLAN

OS

OS

OS

OS

OS OS

1 4

A

C

B

A1

A1

A1

A1

A1A1

A1 A1 A3

A3

A3

A3

A3

A3

A3

A3

CLASSROOM A

WP/PC

CLASSROOM B

DAYLIGHT

PRIMARY

ZONE - TYP.

A1 A3EF-1

A3

EF-1

A1

A1 A1 A3

WP/PCWP/PC

DAYLIGHT CONTROLS NOT REQUIRED

PER LIGHTING PLAN NOTE #4

DAYLIGHT

SECONDARY

ZONE - TYP.

RESTROOM A RESTROOM B

PRELIM

IN

ARY

NOT F

OR

SUBMIT

TAL

JOB#

SHEET #

DATE

SHEET

PROJ.

ADDRESS DRW

TELEPHONE: (503) 749-4949 FAX: (503) 749-4950

P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325

CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com

MODERN BUILDING SYSTEMS, INC. 2023

MODERN BUILDING SYSTEMS, INC.

REUSE OF DOCUMENTS THIS

DOCUMENT AND THE IDEAS AND

DESIGNS INCORPORATED HEREIN

ARE THE PROPERTY OF MODERN

BUILDING SYSTEMS INC. AND ARE

NOT TO BE USED IN WHOLE OR IN

PART FOR ANY OTHER USE OR

PROJECT WITHOUT WRITTEN

AUTHORIZATION.

2023-DS-18

E 2.0

4/3/2023 PRELIM

LIGHTING PLAN

10811 SE 172nd AVE, HAPPY VALLEY, OR 97086

28' x 64' MODULAR CLASSROOM

BJ

NORTH CLACKAMAS SD

3/16" = 1'-0"

LIGHTING PLAN

REV. DESCRIPTION DATE BY

INTERIOR LIGHTING SUMMARY

SUBSITUTIONS WITH EQUAL OR BETTER PERFORMING PRODUCTS ALLOWED WITH APPROVAL FROM MODERN

Description Model Quantity Lamp Wattage Total Wattage

2'x4' LAY-IN FIXTURE LITHONIA, 2BLT4 16 LED 34 W 544 W

13" DIA. SURFACE MOUNT FIXTURE LITHONIA, FMML 13 840 2 LED 28 W 56 W

Total 18 600 W

EXTERIOR LIGHTING SUMMARY

SUBSTITUTIONS WITH EQUAL OR BETTER PERFORMING PRODUCTS ALLOWED WITH APPROVAL FROM

MODERN

Description Model Quantity Lamp Wattage Total Wattage

WALL MOUNT FIXTURE CYBER TECH LIGHTING,

LWP17BZ/DL

3 LED 17 W 51 W

Total 3 51 W

200 AMP

MAIN BREAKER

120/208V

THREE PH.

W/ 2" PVC

STUB-OUT

ONE-LINE DIAGRAM

NO SCALE

(BY MODERN)

#4 CU BARE UFER

GROUND ON SITE

SERVICE

1. EMT CONDUIT SHALL NOT BE USED WITH UNFUSED

CONDUCTORS INSIDE BUILDING LINES

2. FIELD VERIFY AIC RATING REQUIREMENTS

3. N/A

4. GROUNDING TO BE IN ACCORDANCE TO NEC 250

5. SITE INSTALLED PORTION OF ELECTRICAL DISTRIBUTION

SYSTEM. SHALL BE INSTALLED IN ACCORDANCE WITH THESE

APPROVED PLANS

ONE-LINE DIAGRAM NOTES

(BY OTHERS)

SEE NOTE #5

ABOVE

2" GRC & SERVICE

HEAD (SITE

INSTALLED)

2" GRC NIPPLE

STUBBED OUT

WITH 2" METAL

LB

FUTURE

SOLAR

INVERTER

FEEDER FROM

GROUND

MOUNTED ARRAY

(BY OTHERS)

SEE NOTE #5

ABOVE

PRELIM

IN

ARY

NOT F

OR

SUBMIT

TAL

JOB#

SHEET #

DATE

SHEET

PROJ.

ADDRESS DRW

TELEPHONE: (503) 749-4949 FAX: (503) 749-4950

P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325

CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com

MODERN BUILDING SYSTEMS, INC. 2023

MODERN BUILDING SYSTEMS, INC.

REUSE OF DOCUMENTS THIS

DOCUMENT AND THE IDEAS AND

DESIGNS INCORPORATED HEREIN

ARE THE PROPERTY OF MODERN

BUILDING SYSTEMS INC. AND ARE

NOT TO BE USED IN WHOLE OR IN

PART FOR ANY OTHER USE OR

PROJECT WITHOUT WRITTEN

AUTHORIZATION.

2023-DS-18

E 3.0

4/3/2023 PRELIM

ELEC. PANELS & LOAD CALCS.

10811 SE 172nd AVE, HAPPY VALLEY, OR 97086

28' x 64' MODULAR CLASSROOM

BJ

NORTH CLACKAMAS SD

REV. DESCRIPTION DATE BY

NOTE: CONNECTED LOAD FOR LIGHTS IS FROM NEC TABLE 220.12

TOTAL AMPS = 141 A TOTAL AMPS = 145 A

TOTAL VA = 50629 VA TOTAL VA = 52296 VA

CONNECTED LOAD CALCULATED LOAD

AUXILIARY 1200 VA 100.00% 1200 W

FIRE ALARM 1000 VA 100.00% 1000 W

WATER HEATER 1500 VA 125.00% 1875 W

MISCELLANEOUS

37920 VA 100.00% 37920 W

TOTAL HEAT & A/C LOAD

HEATING & A/C (Per Mfg's Specs)

LARGEST MOTOR 48 VA 25.00% 12 VA

EXHAUST FAN 48 VA 100.00% 48 W

MOTORS & COMPRESSORS

DED. RECEPTACLE 0 W

RECEPTACLE 3600 VA 100.00% 3600 W

SIGN CIRCUIT 0 W

LIGHTS 5313 VA 125.00% 6641 W

ITEM CONNECTED LOAD DEMAND FACTOR CALCULATED LOAD

MAIN BREAKER 200 A PHASE 3

BUSS SIZE 200 VOLTAGE 120/208 Wye

TOTAL PANEL VA= 45916 VA 127 A =TOTAL PANEL AMPS

18517 VA 14620 VA 12780 VA

A29 0 VA -- A30 -- --

A27 0 VA 2 A28 30 A For Future Solar Electric

A25 A26

A23 A24

A21 A22

A19 A20

A17 A18

Auxiliary 20 A A15 1 1200 VA 6240 VA -- A16 -- --

Fire Alarm 20 A A13 1 1000 VA 6240 VA 2 A14 60 A Mech Unit B

Water Heater 20 A A11 1 1500 VA 3240 VA -- A12 -- --

Exterior Receptacles 20 A A9 1 360 VA 3240 VA 2 A10 40 A Mech Unit B

Classroom B Receptacles 20 A A7 1 1440 VA 6240 VA -- A8 -- --

Classroom A Receptacles 20 A A5 1 1800 VA 6240 VA 2 A6 60 A Mech Unit A

Classroom B Lighting/Fans 20 A A3 1 340 VA 3240 VA -- A4 -- --

Classroom A Lighting/Fans 20 A A1 1 357 VA 3240 VA 2 A2 40 A Mech Unit A

Load Name Rating Circuit

Number Number of Poles

A B C Number of Poles

Circuit Number

Rating Load Name

MOUNTING Recessed DATE: 4/3/2023 PRELIM

MAIN DISTRIBUTION PANEL PANEL A PROJECT NO: 2023-DS-18

MECHANICAL NOTESMECHANICAL NOTES

1. CONTROLS:

THERMOSTAT:

BARD 8403-060

FACTORY INSTALL OUTDOOR: BARD 8403-061

DOAS CONTROLS INTEGRAL TO FACTORY

EQUIPMENT DESIGN W/ ABOVE CONTROLS

CO2 SENSOR:

BARD S8403-067

DOOR SWITCH CONTROLS ARE NOT INSTALLED,

SINCE EXIT DOORS HAVE AUTOMATIC CLOSING

DEVICES (PER ASHRAE 6.5.10, EXCEPTION #1)

2. DUCTWORK:

MATERIAL:

1" FIBERGLASS (R-4.3) OR 24 GA.

SHEET METAL W/ 26 GA. SHEET

METAL ROUNDS AND FLEX DUCT

ROUNDS AT DIFFUSERS

INSULATING AND SEALING:

DUCTWORK TO BE INSULATED AND

SEALED AT ALL CONNECTIONS

CONSTRUCTION:

DUCTWORK TO BE CONSTRUCTED AS

LOW PRESSURE DUCT SYSTEM

EXHAUST OUTLETS:

FOR ENVIRONMENTAL AIR EXHAUST, A MINIMUM

DISTANCE OF: 3 FEET FROM THE PROPERTY

LINES; 3 FEET FROM OPERABLE OPENINGS INTO

BUILDINGS, AND 10 FEET FROM MECHANICAL

AIR INTAKES SHALL BE PROVIDED PER OMSC

501.3.1.3

3. VOLUME DAMPERS:

PROVIDE VOLUME DAMPERS TO CONTROL

AIRFLOW AT EACH TAKE-OFF OR DIFFUSER

RAFTER

DUCT

1" MIN. SHEET METAL

DUCT HANGER STRAP

AS REQUIRED BY

DUCT MANUFACTURER

12 GA. WIRE

EA. SIDE - TYP.

CEILING LAG

1+/-

HVAC SYMBOLS LEGEND

SYMBOL DESCRIPTION

HEIGHT

℄ (U.N.O)

CEILINGLAY-IN SUPPLY DIFFUSER

FLEX DUCT -

+48" TOPTHERMOSTATT

EXHAUST FAN CEILING

+48" TOPCO2 SENSORCO2

PRELIM

IN

ARY

NOT F

OR

SUBMIT

TAL

JOB#

SHEET #

DATE

SHEET

PROJ.

ADDRESS DRW

TELEPHONE: (503) 749-4949 FAX: (503) 749-4950

P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325

CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com

MODERN BUILDING SYSTEMS, INC. 2023

MODERN BUILDING SYSTEMS, INC.

REUSE OF DOCUMENTS THIS

DOCUMENT AND THE IDEAS AND

DESIGNS INCORPORATED HEREIN

ARE THE PROPERTY OF MODERN

BUILDING SYSTEMS INC. AND ARE

NOT TO BE USED IN WHOLE OR IN

PART FOR ANY OTHER USE OR

PROJECT WITHOUT WRITTEN

AUTHORIZATION.

2023-DS-18

M 0.1

4/3/2023 PRELIM

HVAC NOTES & LEGEND

10811 SE 172nd AVE, HAPPY VALLEY, OR 97086

28' x 64' MODULAR CLASSROOM

BJ

NORTH CLACKAMAS SD

REV. DESCRIPTION DATE BY

MIN. VENTILATION/EXHAUST RATES (OMSC/IMC SECTION 403.3)

Ez = 0.8 FOR SUPPLY/RETURN IN THE CEILING & Ez = 1.0 FOR RETURN IN THE FLOOR PER IMC TABLE 403.3.1.1.1.2

Name Area (Az) Occ. Density

(#/1000 FT2)

People Airflow Rate

(Rp) (CFM/Person)

Area Outdoor Airflow Rate

(Ra)

(CFM/FT2)

Exhaust Airflow Rate

(CFM/FT2)

Qty.

Flush Fixt.

Occ.

Load (Pz)

Occ.

Airflow

(CFM)

Area Airflow

(CFM)

Exhaust Airflow

(CFM)

Air Flow Effectiveness

(Ez)

Zone Outdoor

Airflow Rate (Voz)

CLASSROOM A 790 SF 35 10 0.12 0 0 28 280 95 0 1 375

CLASSROOM B 790 SF 35 10 0.12 0 0 28 280 95 0 1 375

RESTROOM A 64 SF 0 0 0 70 1 0 0 0 70 0

RESTROOM B 64 SF 0 0 0 70 1 0 0 0 70 0

56 560 140

HVAC EQUIPMENT SCHEDULE

SUBSTITUTIONS WITH EQUAL OR BETTER PERFORMING PRODUCTS ALLOWED WITH APPROVAL FROM MODERN

Mark Count Description Manufacturer Model Heating

Efficiency Cooling

Efficiency Weight

(LBS)

Heating Capacity (Btu/h)

Cooling Capacit y (Btu/h) CFM MCA MOP Volts Phase Notes

MECH UNIT A 1 3.0 TON WALL MOUNT HEAT PUMP BARD C36H1A10RP4XXE COP = 3.30 EER = 11.0 380 31,000 35,000 1100 27/52 40/60 230/208 1 10kW HEAT STRIP, ERV AND CURB: TCURBF3642A

MECH UNIT B 1 3.0 TON WALL MOUNT HEAT PUMP BARD C36H1A10RP4XXE COP = 3.30 EER = 11.0 380 31,000 35,000 1100 27/52 40/60 230/208 1 10kW HEAT STRIP, ERV AND CURB: TCURBF3642A

EF-1 2 EXHAUST FAN PANASONIC FV-0511VQ1 - - 8.82 - - 80 .27 20 120/60 1

RC-1 1 ROOF CAP FANTECH RC6P - - 12 - - - - - -

1" = 1'-0"

DUCT SUPPORT

PLUMBING NOTES

1. SUPPLY PIPING AND FITTINGS:

• TYPE 'L' CU

• CHLORINATED POLYVINYL CHLORIDE (CPVC) PLASTIC

SCHED 40

• CROSSLINKED POLYETHYLENE (PEX) PLASTIC

2. SUPPLY PIPE SIZES BASED ON:

• 100 FT. DEVELOPED LENGTH

• 46 - 60 PSI

3. WASTE PIPING:

• ABS - DWV

4. WASTE PIPE SIZES BASED ON:

• 1/4" PER FOOT SLOPE

5. FLOOR DRAINS:

• FLOOR SHALL BE SLOPED TO FLOOR DRAINS PER OPSC/UPC

418.5

• PROVIDE TRAP SEAL PROTECTION PER OPSC/UPC 1007

6. TRAP PRIMERS TO BE MIN. 12" ABOVE FLOOR RIM PER

OPSC 1007.4

7. WATER HAMMER ARRESTER(S):

INSTALL AT FLUSHOMETERS OR QUICK-ACTING VALVES PER

OPSC/UPC 609.10

8. SHOWERS:

• WHEN PRESENT SHALL BE PROVIDED WITH A

THERMOSTATIC BALANCE VALVE PER OPSC/UPC 408.3

• A HAND SHOWER WITH A HOSE 59 INCHES MINIMUM IN

LENGTH, THAT CAN BE USED BOTH AS A FIXED SHOWER

HEAD AND AS A HAND SHOWER SHALL BE PROVIDED

9. DISHWASHER: WHEN PRESENT SHALL BE PROVIDED WITH AIR

GAP FITTING PER OPSC/UPC 807.3

10.CLOTHES WASHER: WHEN PRESENT SHALL BE PROVIDED

WITH A STANDPIPE PER OPSC/UPC 804

11.EXPOSED PIPES AND SURFACES:

• PER 2009 ANSI A117.1, WATER SUPPLY AND DRAINPIPES

UNDER LAVATORIES AND SINKS SHALL BE INSULATED OR

OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT.

THERE SHALL BE NO SHARP OR ABRASIVE SURFACES

UNDER LAVATORIES AND SINKS

12. WATER CLOSET SEATS:

• PER OPSC/UPC 411.3, ADA COMPLIANT TOILET SEATS SHALL

BE OF THE ELONGATED TYPE AND EITHER OF THE OPEN

FRONT TYPE OR HAVE AN AUTOMATIC SEAT COVER

DISPENSER. PLASTIC SEATS SHALL COMPLY WITH IAPMO

Z124.5

13. WATER CLOSETS:

• PER OPSC/UPC 411.1, WATER CLOSET BOWLS FOR PUBLIC

USE SHALL BE OF THE ELONGATED TYPE.

14. FLUSH CONTROLS:

• PER 2009 ANSI 604.6, FLUSH CONTROLS SHALL BE HAND

OPERATED OR AUTOMATIC. HAND OPERATED FLUSH

CONTROLS SHALL COMPLY WITH SECTION 309. FLUSH

CONTROLS SHALL BE LOCATED ON THE OPEN SIDE OF THE

WATER CLOSET.

15. URINALS:

• PER 2009 ANSI 605.2, URINALS SHALL BE OF THE STALL TYPE

OR SHALL BE OF THE WALL HUNG TYPE WITH THE RIM AT 17

INCHES MAXIMUM ABOVE THE FLOOR. WALL HUNG URINALS

SHALL BE 13-1/2 INCHES MINIMUM IN DEPTH MEASURED

FROM THE OUTER FACE OF THE URINAL RIM TO THE WALL

16. WATER HEATING:

• SERVICE WATER HEATING EQUIPMENT SHALL BE PROVIDED

WITH TEMPERATURE CONTROLS PER ASHRAE 7.4.4.1 AND

7.4.4.3 AND WSEC C404.7.3

• HOT WATER FROM PUBLIC-USE LAVATORIES SHALL ALSO BE

CONTROLLED PER OPSC/UPC 407.3

• WATER HEATING EQUIPMENT SHALL BE SUPPLIED WITH

HEAT TRAPS PER ASHRAE 7.4.6 AND WSEC C404.4

• STRAP WATER HEATER TO WALL W/ 26 GA. x 1" SEISMIC STRAP W/ (1) #6 SMST TO TANK AND (1) #3 x 2" BUGLE HEAD

SCREW TO WALL EACH END

• HOT WATER PIPES TO BE INSULATED PER ASHRAE 7.4.3 AND

WSEC C404.6

• NO PEX PIPING WITHIN 18" OF WATER HEATER PER OPSC

/UPC 604.13

• WATER HEATING EQUIPMENT SHALL HAVE NO LESS THAN

THE ENERGY FACTOR EFFICIENCY PER ASHRAE TABLE 7.8

AND WSEC TABLE C404.2

• WATER HEATING EQUIPMENT SHALL BE SUPPLIED WITH

DRAINAGE PER OPSC 507.4 AND UPC 507.5

PRELIM

IN

ARY

NOT F

OR

SUBMIT

TAL

JOB#

SHEET #

DATE

SHEET

PROJ.

ADDRESS DRW

TELEPHONE: (503) 749-4949 FAX: (503) 749-4950

P.O. BOX 110, 9493 PORTER ROAD, AUMSVILLE, OR 97325

CHECK OUT OUR WEB PAGE: www.modernbuildingsystems.com

MODERN BUILDING SYSTEMS, INC. 2023

MODERN BUILDING SYSTEMS, INC.

REUSE OF DOCUMENTS THIS

DOCUMENT AND THE IDEAS AND

DESIGNS INCORPORATED HEREIN

ARE THE PROPERTY OF MODERN

BUILDING SYSTEMS INC. AND ARE

NOT TO BE USED IN WHOLE OR IN

PART FOR ANY OTHER USE OR

PROJECT WITHOUT WRITTEN

AUTHORIZATION.

2023-DS-18

P 0.1

4/3/2023 PRELIM

PLUMBING NOTES

10811 SE 172nd AVE, HAPPY VALLEY, OR 97086

28' x 64' MODULAR CLASSROOM

BJ

NORTH CLACKAMAS SD

REV. DESCRIPTION DATE BY

PLUMBING FIXTURE SCHEDULE1

SUBSTITUTIONS WITH EQUAL OR BETTER PERFORMING PRODUCTS ALLOWED WITH APPROVAL FROM MODERN

Mark Count Description Model Style GPM/GPF WATTS

LAV-1 2 WALL HUNG LAVATORY PROFLO, PF5514WH; FAUCET: OLYMPIA, 3LG161G; MIXING VALVE: SLOAN MIX-60-A VITR. CHINA 0.5

S-1 2 CLASSROOM SINK W/ BUBBLER,

15" x 15" x 5-3/16"

SINK, DAYTON D11515; BUBBLER, ELKAY LK1141A; FAUCET, AMERICAN STANDARD 7074.000 S.S. 2.5

WC-1 1 ADA WATER CLOSET GERBER, MAXWELL MX21-928 (17" HIGH);TANK (RH): GERBER, MAXWELL 28-990-97; SEAT: CHURCH, 295CT TANK 1.28

WC-2 1 ADA WATER CLOSET GERBER, MAXWELL MX21-928 (17" HIGH);TANK (LH): GERBER, MAXWELL 28-990; SEAT: CHURCH, 295CT TANK 1.28

WH-8 1 WATER HEATER - 8 GAL. TANK BOSCH, 3000T-ES8 ELEC. 1500

2023-18 - Sheet - A 0-0 - COVER SHEET
2023-18 - Sheet - A 0-1 - GENERAL NOTES
2023-18 - Sheet - A 0-3 - ABBREVIATIONS & SYMBOLS
2023-18 - Sheet - A 0-4 - SITE LAYOUT
2023-18 - Sheet - A 1-0 - FLOOR PLAN
2023-18 - Sheet - A 2-0 - EXTERIOR ELEVATIONS
2023-18 - Sheet - A 2-1 - EXTERIOR ELEVATIONS
2023-18 - Sheet - A 3-0 - FINISH NOTES
2023-18 - Sheet - A 3-1 - SCHEDULES
2023-18 - Sheet - A 3-2 - DATA SCHEDULES
2023-18 - Sheet - A 4-0 - INTERIOR ELEVATIONS
2023-18 - Sheet - A 4-1 - INTERIOR ELEVATIONS & DETAILS
2023-18 - Sheet - A 5-0 - DETAILS
2023-18 - Sheet - A 5-1 - ADA MOUNTING DETAILS
2023-18 - Sheet - E 0-1 - ELECTRICAL LEGEND & NOTES
2023-18 - Sheet - E 1-0 - ELECTRICAL PLAN
2023-18 - Sheet - E 2-0 - LIGHTING PLAN
2023-18 - Sheet - E 3-0 - ELEC- PANELS & LOAD CALCS-
2023-18 - Sheet - M 0-1 - HVAC NOTES & LEGEND
2023-18 - Sheet - P 0-1 - PLUMBING NOTES

File details come from the government source that posted it. Updated .