2023-24-006_Abatement 6740_124 Ranchette Cir Asbestos Report.pdf

PDF 4 MB Posted

Attached to
Demolition of Condemned Dwellings (Group 6)
Solicitation number
2023-24-006
Issued by
Florence County, South Carolina

About this file

This document is an asbestos inspection report prepared by Asbestos Inspections, LLC for Horry County Government, specifically for a property located at 124 Ranchette Circle in Myrtle Beach, South Carolina. The inspection was completed on April 3, 2023, in preparation for the property's scheduled demolition, with the report finalized on April 20, 2023. The inspection was conducted in accordance with South Carolina Department of Health and Environmental Control (SCDHEC) regulation 61-86.1 and Occupational Safety and Health Administration (OSHA) regulation 29 CFR 1926. The approximately 900 square-foot mobile home structure had sustained significant fire damage, which limited the inspection team's ability to fully access the interior.

Laboratory analysis of samples collected from the property, including drywall, sheet flooring, shingles, and tarpaper, revealed no asbestos-containing materials above the 1% regulatory threshold. The report recommends submitting a copy of the inspection report along with a demolition application to SCDHEC at least 10 working days prior to any demolition activities. While the samples tested negative for asbestos, the report cautions that additional suspect materials might exist in inaccessible areas such as wall voids, pipe chases, or behind exterior veneer. The inspection was performed by Dawn Schoolcraft, who holds multiple professional certifications, including a South Carolina SCDHEC Asbestos Building Inspector license (BI-00738).

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASBESTOS INSPECTION REPORT

124 Ranchette Circle

Myrtle Beach, South Carolina Asbestos Inspections, LLC Project # 2023-01-109

Performed in general accordance with SCDHEC regulation 61-86.1 along with OSHA regulation 29 CFR 1926

Assessment Completed by:

Asbestos Inspections, LLC 4686 Pee Dee Highway

Conway, South Carolina 29527

(843) 995-5197

Dawn Schoolcraft

SCDHEC ID# BI-00738

Assessment Completed For:

Mr. Sam LoFaso with Horry County Government 1515 Fourth Avenue

Conway, South Carolina 29526

Inspection Completed On – April 3, 2023 Report Prepared On – April 20, 2023

Asbestos Inspection Report

Project Number – 2023-01-109 April 20, 2023

TABLE OF CONTENTS

1.0 SIGNATURE PAGE

2.0 COVER LETTER

3.0 EXECUTIVE SUMMARY

1.1 Scope and Purpose

2.1 Facility Conditions

3.1 Findings and Conclusions

4.0 ASBESTOS ASSESSMENT DATA

5.0 CONCLUSIONS

Appendix 1- Site Location Plan and Sample Location Plan Appendix 2- Photographs Appendix 3- Laboratory Results Appendix 4- License

1.0 SIGNATURE PAGE

This report has been performed at the request of Mr. Sam LoFaso with Horry County Government. The inspection was conducted by Mrs. Dawn Schoolcraft with Asbestos Inspections, LLC on April 03, 2023.

The report was prepared and reviewed by the undersigned inspector.

Inspection Performed by: SCDEHC# Signature Date

Dawn Schoolcraft BI-00738 Dawn Schoolcraft April 03, 2023

Report Prepared by:

Dawn Schoolcraft BI-00738 Dawn Schoolcraft April 20, 2023

Report Reviewed by:

Dawn Schoolcraft BI-00738 Dawn Schoolcraft April 20, 2023

2.0 COVER LETTER

Mr. Sam LoFaso with Horry County Government 1515 Fourth Avenue Conway, South Carolina 29526

Subject:

Asbestos Inspection Report 124 Ranchette Circle Myrtle Beach, South Carolina 29588 Asbestos Inspections, LLC Project # 2023-01-109

Asbestos Inspections, LLC has completed an Asbestos Assessment and Inspection for the structure located at 124 Ranchette Circle, in Myrtle Beach, South Carolina. The inspection was completed on April 03, 2023 by a South Carolina Department of Health and Environmental Control (SCDHEC) building inspector.

The following report summarizes the project background, assessment procedures, results, and conclusions. The results presented in this report are indicative of conditions during the time of the inspection and of the specific areas outlined. The information provided in this report should not be used as a bidding document and field conditions should be verified. Should suspect building materials, not included within this report, be identified or impacted during the destructive activities, bulk samples must be collected and analyzed for asbestos content.

I appreciate this opportunity to provide my services. Should you have any questions concerning this report, please contact me at (843) 995-5197.

Sincerely, Asbestos Building Inspector (SCDHEC #BI-00738)

3.0 EXECUTIVE SUMMARY

1.1 Scope and Purpose

Mr. Sam LoFaso with Horry County Government requested this assessment for the structure located at 124 Ranchette Circle in Myrtle Beach, South Carolina. Based on information obtained from you, the structure is scheduled for demolition. The purpose of this assessment was to identify asbestos containing materials (ACMs) prior to demolition.

The inspection was completed in accordance with procedures specified in SCDHEC regulation 61.86.1 along with Occupational Safety and Health Administration (OSHA) regulation 29 Code of the Federal Regulations (CFR) 1926. The representative bulk samples collected were analyzed by a National Voluntary Laboratory Accreditation Program (NVLAP) certified laboratory which is administered by the National Institute of Standards and Technology (NIST). This report has been prepared in accordance with Environmental Protection Agency (EPA) 40 CFR, 763.85(a)(4).

2.1 Facility Conditions

The subject structure is an approximately 900 square-feet, mobile home structure that has sustained significant fire damage leaving many areas unsafe for entry. We were able to sample the majority of suspect building materials from the exterior of the home reaching inside. The interior consists of unfinished drywall ceilings, wood panelled walls, carpeting, and vinyl floor coverings. The exterior consists of vinyl siding with and asphalt shingled roof.

Suspect materials sampled during this inspection include drywall, sheet flooring, shingles, and tarpaper.

The possibility exists that suspect materials were undetected in inaccessible areas such as areas deemed unsafe to enter, underneath or behind contents of units, behind exterior veneer, pipe chases, or wall voids. If additional suspect materials not included in this report are discovered during demolition, bulk samples should be collected and analyzed for asbestos content.

3.1 Findings and Conclusions

The EPA and SCDHEC define materials as asbestos containing if an asbestos content >1% is identified in a representative sample. No asbestos >1% was detected in the suspect materials collected and analyzed:

Material ID Material Regulatory Result Highest Analytical Result Est. Quantity There are no homogenous materials for this project that have tested positive containing asbestos

A copy of this report along with a demolition application should be submitted to SCDHEC at least 10 working days prior to any demolition activities. Additionally, a copy of this report should be provided to the contractors to assist with compliance with applicable State and Federal regulations.

The results presented in this report are indicative of conditions during the time of the assessment. The information provided in this report should not be used as a bidding document and field conditions and quantities should be verified.

4.0 ASBESTOS ASSESSMENT DATA

The assessment was performed by observing and sampling suspect ACMs in the unit prior to the scheduled renovations. Representative bulk samples were then extracted, recorded on a chain of custody, and submitted to Eurofins/CEI Labs of Cary, North Carolina for laboratory analysis. The samples were tested via Polarized Light Microscopy (PLM); however, SCDHEC requires a Transmission Electron Microscopy (TEM) test be performed for all non-friable organically bound material found negative via PLM.

The following tables exhibits the suspect material sampled, location, quantity of material sampled, condition of material, potential for future disturbance, and laboratory analysis.

All Materials Sampled

Material Id

Material Space Name

Quantity Material Category

Current Condition

Friability Damage Potential

Physical Assessment Category

Unfinished

Drywall Walls and Ceilings

1500 sq.

f.t

Miscellaneous Significantly

Damaged Friable

(RACM)

Potential for

Significant Damage

Sheet

Flooring Bathroom 50 sq. ft. Miscellaneous

Significantly Damaged

Category I Nonfriable

Potential for

Significant Damage

Shingle/ Tarpaper

Roof 900 sq.

ft.

Miscellaneous

Significantly Damaged

Category I Nonfriable

Potential for

Significant Damage

Sample Results

Sample # Material % Mineral Type Regulatory Result Analysis Type 001A Brown, White Drywall ND ND Tested Negative by Lab PLM 001B Brown, White Drywall ND ND Tested Negative by Lab PLM 001C Brown, White Drywall ND ND Tested Negative by Lab PLM 002A Gray Sheet Flooring ND ND Tested Negative by Lab PLM 002B Gray Sheet Flooring ND ND Tested Negative by Lab PLM 002C Gray Sheet Flooring ND ND Tested Negative by Lab TEM

Sample # Material % Mineral Type Regulatory Result Analysis Type

003A Black Shingle ND ND Tested Negative by Lab PLM

Black Tarpaper ND ND Tested Negative by Lab PLM

003B Black Shingle ND ND Tested Negative by Lab PLM

Black Tarpaper ND ND Tested Negative by Lab PLM

003C Black Shingle ND ND Tested Negative by Lab TEM

Black Tarpaper ND ND Tested Negative by Lab TEM

Please understand that quantities are estimated and should not be used for bidding purposes. Field conditions should be verified prior to bidding.

Site location plan and sample location plan is identified as Figures 1 and 2 in Appendix 1 of this report, photographs are in Appendix 2, laboratory results are in Appendix 3, and license is in Appendix 4.

5.0 CONCLUSIONS

The EPA and SCDHEC define materials as asbestos containing if an asbestos content >1% is detected in a representative sample. No asbestos >1 % was detected in the suspect materials sampled and analyzed for the structure located at 124 Ranchette Circle in Myrtle Beach, South Carolina:

Material ID Material Regulatory Result Highest Analytical Result Est. Quantity There are no homogenous materials for this project that have tested positive containing asbestos

A copy of this report along with a demolition application should be submitted to SCDHEC at least 10 working days prior to any demolition activities. Additionally, a copy of this report should be provided to the contractors to assist with compliance with applicable State and Federal regulations.

The possibility exists that suspect materials were undetected in inaccessible areas such as areas deemed unsafe to enter, behind exterior veneer, pipe chases, or wall voids. If additional suspect materials not included in this report are discovered during renovations, bulk samples should be collected and analyzed for asbestos content.

APPENDIX 1

Site Location Plan and Sample Location Plan

Site Location Plan 124 Ranchette Cir Myrtle Beach, SC Project # - 2023-01-109

Scale: Not to Scale Reviewed By: DS Date: 4/4/23 Source: N/A

Figure 1

Subject Property

Asbestos Sample Location Plan 124 Ranchette Cir Myrtle Beach, SC Project # - 2023-01-109

Figure 2 Scale: Not to Scale Reviewed By: DS Date: 3/10/23 Source: N/A

Figure 2

LEGEND

Sample Location

Asbestos Containing Sample Location

001A

Bath

001B

001C

002A-C

003A-C

APPENDIX 2

Photographs

Site Photos

Exterior

Interior

Exterior

APPENDIX 3

Laboratory Results

April 14, 2023

Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527

CLIENT PROJECT: 124 Ranchette Cir

CEI LAB CODE: B237430

Dear Customer:

Enclosed are asbestos analysis results for PLM Bulk samples received at our laboratory on April 4, 2023. The samples were analyzed for asbestos using polarizing light microscopy (PLM) per the EPA 600 Method.

Sample results containing >1% asbestos are considered asbestos-containing materials (ACMs) per EPA regulatory requirements. The detection limit for the EPA 600 Method is <1% asbestos by weight as determined by visual estimation.

Thank you for your business and we look forward to continuing good relations.

730 SE Maynard Road • Cary, NC 27511 • 919.481.1413

Tianbao Bai, Ph.D., CIH Laboratory Director

Kind Regards, ASBESTOS ANALYTICAL REPORT

By: Polarized Light Microscopy

Prepared for

Asbestos Inspections LLC

CLIENT PROJECT:

LAB CODE:

TEST METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

REPORT DATE:

TOTAL SAMPLES ANALYZED:

# SAMPLES >1% ASBESTOS:

124 Ranchette Cir

04/14/23

B237430

730 SE Maynard Road • Cary, NC 27511 • 919.481.1413

Asbestos Report Summary By: POLARIZING LIGHT MICROSCOPY

PROJECT: 124 Ranchette Cir LAB CODE: B237430

Client ID Lab ID Color Sample Description

ASBESTOS

%Layer

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

001A B237430.01 Brown,White Drywall None Detected001A

001B B237430.02 Brown,White Drywall None Detected001B

001C B237430.03 Brown,White Drywall None Detected001C

002A B237430.04 Gray Sheet Flooring None Detected002A

002B B237430.05 Gray Sheet Flooring None Detected002B

002C B237430.06 Sample Submitted for TEM Analysis

002C

003A Layer 1 B237430.07 Black Shingle None Detected003A

Layer 2 B237430.07 Black Tarpaper None Detected

003B Layer 1 B237430.08 Black Shingle None Detected003B

Layer 2 B237430.08 Black Tarpaper None Detected

003C Layer 1 B237430.09 Sample Submitted for TEM Analysis

003C

Layer 2 B237430.09 Sample Submitted for TEM Analysis

Page 1 of 1730 SE Maynard Road • Cary, NC 27511 • 919.481.1413

ASBESTOS BULK ANALYSIS

Lab Code: B237430 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527

Project: 124 Ranchette Cir

Fibrous

Brown,White Drywall001A

B237430.01 20% 2%

Heterogeneous

Fibrous Bound

78%Cellulose Fiberglass

Gypsum None Detected

Brown,White Drywall001B

B237430.02 20% 2%

Heterogeneous

Fibrous Bound

78%Cellulose Fiberglass

Gypsum None Detected

Brown,White Drywall001C

B237430.03 20% 2%

Heterogeneous

Fibrous Bound

78%Cellulose Fiberglass

Gypsum None Detected

Gray Sheet Flooring002A

B237430.04 Homogeneous

Non-fibrous Bound

90% 10%

Vinyl Binder

None Detected

Gray Sheet Flooring002B

B237430.05 Homogeneous

Non-fibrous Bound

90% 10%

Vinyl Binder

None Detected

Sample Submitted for TEM Analysis

002C B237430.06

Black 003A

B237430.07

50%Heterogeneous

Fibrous Bound

40% 10%

Fiberglass Tar Gravel

None Detected Layer 1

Shingle

Black Tarpaper

B237430.07 70%Heterogeneous

Fibrous Bound

30%Fiberglass Tar None DetectedLayer 2

Page 1 of 3730 SE Maynard Road • Cary, NC 27511 • 919.481.1413

Lab Code: B237430 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527

Project: 124 Ranchette Cir

Fibrous

Black 003B

B237430.08

50%Heterogeneous

Fibrous Bound

40% 10%

Fiberglass Tar Gravel

None Detected Layer 1

Shingle

Black Tarpaper

B237430.08 70%Heterogeneous

Fibrous Bound

30%Fiberglass Tar None DetectedLayer 2

003C

B237430.09 Layer 1

Sample Submitted for TEM Analysis

Sample Submitted for TEM AnalysisB237430.09

Layer 2

Page 2 of 3730 SE Maynard Road • Cary, NC 27511 • 919.481.1413

LEGEND: Non-Anth = Non-Asbestiform Anthophyllite Non-Trem = Non-Asbestiform Tremolite Calc Carb = Calcium Carbonate

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

REPORTING LIMIT: <1% by visual estimation

REPORTING LIMIT FOR POINT COUNTS: 0.25% by 400 Points or 0.1% by 1,000 Points

REGULATORY LIMIT: >1% by weight

Due to the limitations of the EPA 600 method, nonfriable organically bound materials (NOBs) such as vinyl floor tiles can be difficult to analyze via polarized light microscopy (PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request.

This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results.

Interpretation of the analytical results is the sole responsibility of the client. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.

Information provided by customer includes customer sample ID and sample description.

ANALYST: APPROVED BY:

Tianbao Bai, Ph.D., CIH Laboratory Director

Nicholas Moore

April 18, 2023

Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527

CLIENT PROJECT: 124 Ranchette Cir

LAB CODE: T230881

Dear Customer:

Enclosed are asbestos analysis results for TEM bulk samples received at our laboratory on April 11, 2023. The samples were analyzed for asbestos using transmission electron microscopy (TEM) per Chatfield/EPA 600/R-93/116 Sec. 2.5.5.1 method.

Sample results containing > 1% asbestos are considered asbestos-containing materials (ACMs) per the EPA regulatory requirements. The detection limit for the TEM Chatfield/EPA 600/R-93/116 Sec. 2.5.5.1 method is <1% depending on the processed weight and constituents of the sample.

Thank you for your business and we look forward to continuing good relations.

Tianbao Bai, Ph.D., CIH Laboratory Director

Kind Regards, ASBESTOS ANALYTICAL REPORT

By: Transmission Electron Microscopy

Prepared for

Asbestos Inspections LLC

CLIENT PROJECT:

LAB CODE:

TEST METHOD: Bulk Chatfield EPA 600 / R93 / 116 Sec. 2.5.5.1

REPORT DATE:

124 Ranchette Cir

04/18/23

T230881

By: TRANSMISSION ELECTRON MICROSCOPY

Lab Code: T230881 Date Received: 04-11-23 Date Analyzed: 04-18-23 Date Reported: 04-18-23

Client ID Lab ID

Material Description

TEM BULK CHATFIELD / EPA 600 / R93 / 116 Sec. 2.5.5.1

Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527

Project: 124 Ranchette Cir

Sample Weight

(g)

Organic Material

Acid Soluble Material

Acid Insoluble Material

Asbestos

T57942 002C Gray Sheet Flooring 0.282 56.7 39 4.3 None

Detected

T57943 003C Black Shingle 0.453 20.8 38.9 40.3 None

Detected

T57944 003C Black Tarpaper 0.535 15.5 62.8 21.7 None

Detected

LEGEND: None

METHOD: CHATFIELD & EPA/600/R-93/116 Sec. 2.5.5.1

LIMIT OF DETECTION: Varies with the weight and constituents of the sample (<1%)

REGULATORY LIMIT: >1% by weight

This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI (ECEI). ECEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results.

Interpretation of the analytical results is the sole responsibility of the client. Estimated measurement of uncertainty is available on request and in compliance with regulatory requirements. Samples were received in acceptable condition unless otherwise noted.

Information provided by customer includes customer sample ID, location, volume and area as well as date and time of sampling.

ECEI recommends between 0.20 and 0.50 grams of sample material for TEM bulk analysis.

Any weight below 0.10 grams is considered below protocol guidelines.

**Indicates sample weight below 0.05 grams and is considered insufficient for quantitative analysis.

ANALYST: APPROVED BY:

Tianbao Bai, Ph.D., CIH Laboratory Director

Stacy Ulrich

APPENDIX 4

License

12884, 06/30/2023, North Carolina, Dawn

Schoolcraft

1909008, 09/30/2023, South Carolina, Dawn

LBP-R-I162035-2, 03/16/2024, South Carolina, BI-00738, 06/06/2023, South Carolina, Dawn

File details come from the government source that posted it. Updated .