2023-24-006_Abatement 6740_124 Ranchette Cir Asbestos Report.pdf
PDF 4 MB Posted
- Attached to
- Demolition of Condemned Dwellings (Group 6)
- Solicitation number
- 2023-24-006
- Issued by
- Florence County, South Carolina
About this file
This document is an asbestos inspection report prepared by Asbestos Inspections, LLC for Horry County Government, specifically for a property located at 124 Ranchette Circle in Myrtle Beach, South Carolina. The inspection was completed on April 3, 2023, in preparation for the property's scheduled demolition, with the report finalized on April 20, 2023. The inspection was conducted in accordance with South Carolina Department of Health and Environmental Control (SCDHEC) regulation 61-86.1 and Occupational Safety and Health Administration (OSHA) regulation 29 CFR 1926. The approximately 900 square-foot mobile home structure had sustained significant fire damage, which limited the inspection team's ability to fully access the interior.
Laboratory analysis of samples collected from the property, including drywall, sheet flooring, shingles, and tarpaper, revealed no asbestos-containing materials above the 1% regulatory threshold. The report recommends submitting a copy of the inspection report along with a demolition application to SCDHEC at least 10 working days prior to any demolition activities. While the samples tested negative for asbestos, the report cautions that additional suspect materials might exist in inaccessible areas such as wall voids, pipe chases, or behind exterior veneer. The inspection was performed by Dawn Schoolcraft, who holds multiple professional certifications, including a South Carolina SCDHEC Asbestos Building Inspector license (BI-00738).
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ASBESTOS INSPECTION REPORT
124 Ranchette Circle
Myrtle Beach, South Carolina Asbestos Inspections, LLC Project # 2023-01-109
Performed in general accordance with SCDHEC regulation 61-86.1 along with OSHA regulation 29 CFR 1926
Assessment Completed by:
Asbestos Inspections, LLC 4686 Pee Dee Highway
Conway, South Carolina 29527
(843) 995-5197
Dawn Schoolcraft
SCDHEC ID# BI-00738
Assessment Completed For:
Mr. Sam LoFaso with Horry County Government 1515 Fourth Avenue
Conway, South Carolina 29526
Inspection Completed On – April 3, 2023 Report Prepared On – April 20, 2023
Asbestos Inspection Report
Project Number – 2023-01-109 April 20, 2023
TABLE OF CONTENTS
1.0 SIGNATURE PAGE
2.0 COVER LETTER
3.0 EXECUTIVE SUMMARY
1.1 Scope and Purpose
2.1 Facility Conditions
3.1 Findings and Conclusions
4.0 ASBESTOS ASSESSMENT DATA
5.0 CONCLUSIONS
Appendix 1- Site Location Plan and Sample Location Plan Appendix 2- Photographs Appendix 3- Laboratory Results Appendix 4- License
1.0 SIGNATURE PAGE
This report has been performed at the request of Mr. Sam LoFaso with Horry County Government. The inspection was conducted by Mrs. Dawn Schoolcraft with Asbestos Inspections, LLC on April 03, 2023.
The report was prepared and reviewed by the undersigned inspector.
Inspection Performed by: SCDEHC# Signature Date
Dawn Schoolcraft BI-00738 Dawn Schoolcraft April 03, 2023
Report Prepared by:
Dawn Schoolcraft BI-00738 Dawn Schoolcraft April 20, 2023
Report Reviewed by:
Dawn Schoolcraft BI-00738 Dawn Schoolcraft April 20, 2023
2.0 COVER LETTER
Mr. Sam LoFaso with Horry County Government 1515 Fourth Avenue Conway, South Carolina 29526
Subject:
Asbestos Inspection Report 124 Ranchette Circle Myrtle Beach, South Carolina 29588 Asbestos Inspections, LLC Project # 2023-01-109
Asbestos Inspections, LLC has completed an Asbestos Assessment and Inspection for the structure located at 124 Ranchette Circle, in Myrtle Beach, South Carolina. The inspection was completed on April 03, 2023 by a South Carolina Department of Health and Environmental Control (SCDHEC) building inspector.
The following report summarizes the project background, assessment procedures, results, and conclusions. The results presented in this report are indicative of conditions during the time of the inspection and of the specific areas outlined. The information provided in this report should not be used as a bidding document and field conditions should be verified. Should suspect building materials, not included within this report, be identified or impacted during the destructive activities, bulk samples must be collected and analyzed for asbestos content.
I appreciate this opportunity to provide my services. Should you have any questions concerning this report, please contact me at (843) 995-5197.
Sincerely, Asbestos Building Inspector (SCDHEC #BI-00738)
3.0 EXECUTIVE SUMMARY
1.1 Scope and Purpose
Mr. Sam LoFaso with Horry County Government requested this assessment for the structure located at 124 Ranchette Circle in Myrtle Beach, South Carolina. Based on information obtained from you, the structure is scheduled for demolition. The purpose of this assessment was to identify asbestos containing materials (ACMs) prior to demolition.
The inspection was completed in accordance with procedures specified in SCDHEC regulation 61.86.1 along with Occupational Safety and Health Administration (OSHA) regulation 29 Code of the Federal Regulations (CFR) 1926. The representative bulk samples collected were analyzed by a National Voluntary Laboratory Accreditation Program (NVLAP) certified laboratory which is administered by the National Institute of Standards and Technology (NIST). This report has been prepared in accordance with Environmental Protection Agency (EPA) 40 CFR, 763.85(a)(4).
2.1 Facility Conditions
The subject structure is an approximately 900 square-feet, mobile home structure that has sustained significant fire damage leaving many areas unsafe for entry. We were able to sample the majority of suspect building materials from the exterior of the home reaching inside. The interior consists of unfinished drywall ceilings, wood panelled walls, carpeting, and vinyl floor coverings. The exterior consists of vinyl siding with and asphalt shingled roof.
Suspect materials sampled during this inspection include drywall, sheet flooring, shingles, and tarpaper.
The possibility exists that suspect materials were undetected in inaccessible areas such as areas deemed unsafe to enter, underneath or behind contents of units, behind exterior veneer, pipe chases, or wall voids. If additional suspect materials not included in this report are discovered during demolition, bulk samples should be collected and analyzed for asbestos content.
3.1 Findings and Conclusions
The EPA and SCDHEC define materials as asbestos containing if an asbestos content >1% is identified in a representative sample. No asbestos >1% was detected in the suspect materials collected and analyzed:
Material ID Material Regulatory Result Highest Analytical Result Est. Quantity There are no homogenous materials for this project that have tested positive containing asbestos
A copy of this report along with a demolition application should be submitted to SCDHEC at least 10 working days prior to any demolition activities. Additionally, a copy of this report should be provided to the contractors to assist with compliance with applicable State and Federal regulations.
The results presented in this report are indicative of conditions during the time of the assessment. The information provided in this report should not be used as a bidding document and field conditions and quantities should be verified.
4.0 ASBESTOS ASSESSMENT DATA
The assessment was performed by observing and sampling suspect ACMs in the unit prior to the scheduled renovations. Representative bulk samples were then extracted, recorded on a chain of custody, and submitted to Eurofins/CEI Labs of Cary, North Carolina for laboratory analysis. The samples were tested via Polarized Light Microscopy (PLM); however, SCDHEC requires a Transmission Electron Microscopy (TEM) test be performed for all non-friable organically bound material found negative via PLM.
The following tables exhibits the suspect material sampled, location, quantity of material sampled, condition of material, potential for future disturbance, and laboratory analysis.
All Materials Sampled
Material Id
Material Space Name
Quantity Material Category
Current Condition
Friability Damage Potential
Physical Assessment Category
Unfinished
Drywall Walls and Ceilings
1500 sq.
f.t
Miscellaneous Significantly
Damaged Friable
(RACM)
Potential for
Significant Damage
Sheet
Flooring Bathroom 50 sq. ft. Miscellaneous
Significantly Damaged
Category I Nonfriable
Potential for
Significant Damage
Shingle/ Tarpaper
Roof 900 sq.
ft.
Miscellaneous
Significantly Damaged
Category I Nonfriable
Potential for
Significant Damage
Sample Results
Sample # Material % Mineral Type Regulatory Result Analysis Type 001A Brown, White Drywall ND ND Tested Negative by Lab PLM 001B Brown, White Drywall ND ND Tested Negative by Lab PLM 001C Brown, White Drywall ND ND Tested Negative by Lab PLM 002A Gray Sheet Flooring ND ND Tested Negative by Lab PLM 002B Gray Sheet Flooring ND ND Tested Negative by Lab PLM 002C Gray Sheet Flooring ND ND Tested Negative by Lab TEM
Sample # Material % Mineral Type Regulatory Result Analysis Type
003A Black Shingle ND ND Tested Negative by Lab PLM
Black Tarpaper ND ND Tested Negative by Lab PLM
003B Black Shingle ND ND Tested Negative by Lab PLM
Black Tarpaper ND ND Tested Negative by Lab PLM
003C Black Shingle ND ND Tested Negative by Lab TEM
Black Tarpaper ND ND Tested Negative by Lab TEM
Please understand that quantities are estimated and should not be used for bidding purposes. Field conditions should be verified prior to bidding.
Site location plan and sample location plan is identified as Figures 1 and 2 in Appendix 1 of this report, photographs are in Appendix 2, laboratory results are in Appendix 3, and license is in Appendix 4.
5.0 CONCLUSIONS
The EPA and SCDHEC define materials as asbestos containing if an asbestos content >1% is detected in a representative sample. No asbestos >1 % was detected in the suspect materials sampled and analyzed for the structure located at 124 Ranchette Circle in Myrtle Beach, South Carolina:
Material ID Material Regulatory Result Highest Analytical Result Est. Quantity There are no homogenous materials for this project that have tested positive containing asbestos
A copy of this report along with a demolition application should be submitted to SCDHEC at least 10 working days prior to any demolition activities. Additionally, a copy of this report should be provided to the contractors to assist with compliance with applicable State and Federal regulations.
The possibility exists that suspect materials were undetected in inaccessible areas such as areas deemed unsafe to enter, behind exterior veneer, pipe chases, or wall voids. If additional suspect materials not included in this report are discovered during renovations, bulk samples should be collected and analyzed for asbestos content.
APPENDIX 1
Site Location Plan and Sample Location Plan
Site Location Plan 124 Ranchette Cir Myrtle Beach, SC Project # - 2023-01-109
Scale: Not to Scale Reviewed By: DS Date: 4/4/23 Source: N/A
Figure 1
Subject Property
Asbestos Sample Location Plan 124 Ranchette Cir Myrtle Beach, SC Project # - 2023-01-109
Figure 2 Scale: Not to Scale Reviewed By: DS Date: 3/10/23 Source: N/A
Figure 2
LEGEND
Sample Location
Asbestos Containing Sample Location
001A
Bath
001B
001C
002A-C
003A-C
APPENDIX 2
Photographs
Site Photos
Exterior
Interior
Exterior
APPENDIX 3
Laboratory Results
April 14, 2023
Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
CLIENT PROJECT: 124 Ranchette Cir
CEI LAB CODE: B237430
Dear Customer:
Enclosed are asbestos analysis results for PLM Bulk samples received at our laboratory on April 4, 2023. The samples were analyzed for asbestos using polarizing light microscopy (PLM) per the EPA 600 Method.
Sample results containing >1% asbestos are considered asbestos-containing materials (ACMs) per EPA regulatory requirements. The detection limit for the EPA 600 Method is <1% asbestos by weight as determined by visual estimation.
Thank you for your business and we look forward to continuing good relations.
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Tianbao Bai, Ph.D., CIH Laboratory Director
Kind Regards, ASBESTOS ANALYTICAL REPORT
By: Polarized Light Microscopy
Prepared for
Asbestos Inspections LLC
CLIENT PROJECT:
LAB CODE:
TEST METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
REPORT DATE:
TOTAL SAMPLES ANALYZED:
# SAMPLES >1% ASBESTOS:
124 Ranchette Cir
04/14/23
B237430
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Asbestos Report Summary By: POLARIZING LIGHT MICROSCOPY
PROJECT: 124 Ranchette Cir LAB CODE: B237430
Client ID Lab ID Color Sample Description
ASBESTOS
%Layer
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
001A B237430.01 Brown,White Drywall None Detected001A
001B B237430.02 Brown,White Drywall None Detected001B
001C B237430.03 Brown,White Drywall None Detected001C
002A B237430.04 Gray Sheet Flooring None Detected002A
002B B237430.05 Gray Sheet Flooring None Detected002B
002C B237430.06 Sample Submitted for TEM Analysis
002C
003A Layer 1 B237430.07 Black Shingle None Detected003A
Layer 2 B237430.07 Black Tarpaper None Detected
003B Layer 1 B237430.08 Black Shingle None Detected003B
Layer 2 B237430.08 Black Tarpaper None Detected
003C Layer 1 B237430.09 Sample Submitted for TEM Analysis
003C
Layer 2 B237430.09 Sample Submitted for TEM Analysis
Page 1 of 1730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
ASBESTOS BULK ANALYSIS
Lab Code: B237430 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 124 Ranchette Cir
Fibrous
Brown,White Drywall001A
B237430.01 20% 2%
Heterogeneous
Fibrous Bound
78%Cellulose Fiberglass
Gypsum None Detected
Brown,White Drywall001B
B237430.02 20% 2%
Heterogeneous
Fibrous Bound
78%Cellulose Fiberglass
Gypsum None Detected
Brown,White Drywall001C
B237430.03 20% 2%
Heterogeneous
Fibrous Bound
78%Cellulose Fiberglass
Gypsum None Detected
Gray Sheet Flooring002A
B237430.04 Homogeneous
Non-fibrous Bound
90% 10%
Vinyl Binder
None Detected
Gray Sheet Flooring002B
B237430.05 Homogeneous
Non-fibrous Bound
90% 10%
Vinyl Binder
None Detected
Sample Submitted for TEM Analysis
002C B237430.06
Black 003A
B237430.07
50%Heterogeneous
Fibrous Bound
40% 10%
Fiberglass Tar Gravel
None Detected Layer 1
Shingle
Black Tarpaper
B237430.07 70%Heterogeneous
Fibrous Bound
30%Fiberglass Tar None DetectedLayer 2
Page 1 of 3730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Lab Code: B237430 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 124 Ranchette Cir
Fibrous
Black 003B
B237430.08
50%Heterogeneous
Fibrous Bound
40% 10%
Fiberglass Tar Gravel
None Detected Layer 1
Shingle
Black Tarpaper
B237430.08 70%Heterogeneous
Fibrous Bound
30%Fiberglass Tar None DetectedLayer 2
003C
B237430.09 Layer 1
Sample Submitted for TEM Analysis
Sample Submitted for TEM AnalysisB237430.09
Layer 2
Page 2 of 3730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
LEGEND: Non-Anth = Non-Asbestiform Anthophyllite Non-Trem = Non-Asbestiform Tremolite Calc Carb = Calcium Carbonate
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
REPORTING LIMIT: <1% by visual estimation
REPORTING LIMIT FOR POINT COUNTS: 0.25% by 400 Points or 0.1% by 1,000 Points
REGULATORY LIMIT: >1% by weight
Due to the limitations of the EPA 600 method, nonfriable organically bound materials (NOBs) such as vinyl floor tiles can be difficult to analyze via polarized light microscopy (PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request.
This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results.
Interpretation of the analytical results is the sole responsibility of the client. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.
Information provided by customer includes customer sample ID and sample description.
ANALYST: APPROVED BY:
Tianbao Bai, Ph.D., CIH Laboratory Director
Nicholas Moore
April 18, 2023
Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
CLIENT PROJECT: 124 Ranchette Cir
LAB CODE: T230881
Dear Customer:
Enclosed are asbestos analysis results for TEM bulk samples received at our laboratory on April 11, 2023. The samples were analyzed for asbestos using transmission electron microscopy (TEM) per Chatfield/EPA 600/R-93/116 Sec. 2.5.5.1 method.
Sample results containing > 1% asbestos are considered asbestos-containing materials (ACMs) per the EPA regulatory requirements. The detection limit for the TEM Chatfield/EPA 600/R-93/116 Sec. 2.5.5.1 method is <1% depending on the processed weight and constituents of the sample.
Thank you for your business and we look forward to continuing good relations.
Tianbao Bai, Ph.D., CIH Laboratory Director
Kind Regards, ASBESTOS ANALYTICAL REPORT
By: Transmission Electron Microscopy
Prepared for
Asbestos Inspections LLC
CLIENT PROJECT:
LAB CODE:
TEST METHOD: Bulk Chatfield EPA 600 / R93 / 116 Sec. 2.5.5.1
REPORT DATE:
124 Ranchette Cir
04/18/23
T230881
By: TRANSMISSION ELECTRON MICROSCOPY
Lab Code: T230881 Date Received: 04-11-23 Date Analyzed: 04-18-23 Date Reported: 04-18-23
Client ID Lab ID
Material Description
TEM BULK CHATFIELD / EPA 600 / R93 / 116 Sec. 2.5.5.1
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 124 Ranchette Cir
Sample Weight
(g)
Organic Material
Acid Soluble Material
Acid Insoluble Material
Asbestos
T57942 002C Gray Sheet Flooring 0.282 56.7 39 4.3 None
Detected
T57943 003C Black Shingle 0.453 20.8 38.9 40.3 None
Detected
T57944 003C Black Tarpaper 0.535 15.5 62.8 21.7 None
Detected
LEGEND: None
METHOD: CHATFIELD & EPA/600/R-93/116 Sec. 2.5.5.1
LIMIT OF DETECTION: Varies with the weight and constituents of the sample (<1%)
REGULATORY LIMIT: >1% by weight
This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI (ECEI). ECEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results.
Interpretation of the analytical results is the sole responsibility of the client. Estimated measurement of uncertainty is available on request and in compliance with regulatory requirements. Samples were received in acceptable condition unless otherwise noted.
Information provided by customer includes customer sample ID, location, volume and area as well as date and time of sampling.
ECEI recommends between 0.20 and 0.50 grams of sample material for TEM bulk analysis.
Any weight below 0.10 grams is considered below protocol guidelines.
**Indicates sample weight below 0.05 grams and is considered insufficient for quantitative analysis.
ANALYST: APPROVED BY:
Tianbao Bai, Ph.D., CIH Laboratory Director
Stacy Ulrich
APPENDIX 4
License
12884, 06/30/2023, North Carolina, Dawn
Schoolcraft
1909008, 09/30/2023, South Carolina, Dawn
LBP-R-I162035-2, 03/16/2024, South Carolina, BI-00738, 06/06/2023, South Carolina, Dawn
File details come from the government source that posted it. Updated .