2023-24-006_Abatement 3888_873 Pint Cir Asbestos Report.pdf
PDF 4 MB Posted
- Attached to
- Demolition of Condemned Dwellings (Group 6)
- Solicitation number
- 2023-24-006
- Issued by
- Florence County, South Carolina
About this file
This document is an Asbestos Inspection Report prepared by Asbestos Inspections, LLC for Horry County Government, specifically for a property located at 873 Pint Circle in Longs, South Carolina. The inspection was conducted on April 3, 2023, and the report was prepared on April 20, 2023, in accordance with SCDHEC regulation 61-86.1 and OSHA regulation 29 CFR 1926. The purpose of the inspection was to identify asbestos-containing materials (ACMs) prior to the scheduled demolition of the structure, which appears to be comprised of two mobile homes joined with additions and is approximately 1,700 square feet.
The laboratory analysis, conducted by Eurofins/CEI Labs using Polarized Light Microscopy (PLM) and Transmission Electron Microscopy (TEM), found no asbestos-containing materials exceeding the 1% threshold in any of the sampled materials, including sheet floor, mastic, drywall, joint compound, shingles, and tarpaper. The structure was noted to be in significantly damaged condition, with overgrown vegetation, fallen roofs and ceilings, and partially inaccessible interior spaces. The report recommends that if additional suspect materials are discovered during demolition, they should be sampled and analyzed for asbestos content, and a copy of the report should be submitted to SCDHEC at least 10 working days prior to any demolition activities.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ASBESTOS INSPECTION REPORT
873 Pint Circle
Longs, South Carolina Asbestos Inspections, LLC Project # 2023-01-107
Performed in general accordance with SCDHEC regulation 61-86.1 along with OSHA regulation 29 CFR 1926
Assessment Completed by:
Asbestos Inspections, LLC 4686 Pee Dee Highway
Conway, South Carolina 29527
(843) 995-5197
Dawn Schoolcraft
SCDHEC ID# BI-00738
Assessment Completed For:
Mr. Sam LoFaso with Horry County Government 1515 Fourth Avenue
Conway, South Carolina 29526
Inspection Completed On – April 3, 2023 Report Prepared On – April 20, 2023
Asbestos Inspection Report
Project Number – 2023-01-107 April 20, 2023
TABLE OF CONTENTS
1.0 SIGNATURE PAGE
2.0 COVER LETTER
3.0 EXECUTIVE SUMMARY
1.1 Scope and Purpose
2.1 Facility Conditions
3.1 Findings and Conclusions
4.0 ASBESTOS ASSESSMENT DATA
5.0 CONCLUSIONS
Appendix 1- Site Location Plan and Sample Location Plan Appendix 2- Photographs Appendix 3- Laboratory Results Appendix 4- License
1.0 SIGNATURE PAGE
This report has been performed at the request of Mr. Sam LoFaso with Horry County Government. The inspection was conducted by Mrs. Dawn Schoolcraft with Asbestos Inspections, LLC on April 03, 2023.
The report was prepared and reviewed by the undersigned inspector.
Inspection Performed by: SCDEHC# Signature Date
Dawn Schoolcraft BI-00738 Dawn Schoolcraft April 03, 2023
Report Prepared by:
Dawn Schoolcraft BI-00738 Dawn Schoolcraft April 20, 2023
Report Reviewed by:
Dawn Schoolcraft BI-00738 Dawn Schoolcraft April 20, 2023
2.0 COVER LETTER
Mr. Sam LoFaso with Horry County Government 1515 Fourth Avenue Conway, South Carolina 29526
Subject:
Asbestos Inspection Report 873 Pint Circle Longs, South Carolina 29568 Asbestos Inspections, LLC Project # 2023-01-107
Asbestos Inspections, LLC has completed an Asbestos Assessment and Inspection for the structure located at 873 Pint Circle, in Longs, South Carolina. The inspection was completed on April 03, 2023 by a South Carolina Department of Health and Environmental Control (SCDHEC) building inspector.
The following report summarizes the project background, assessment procedures, results, and conclusions. The results presented in this report are indicative of conditions during the time of the inspection and of the specific areas outlined. The information provided in this report should not be used as a bidding document and field conditions should be verified. Should suspect building materials, not included within this report, be identified or impacted during the destructive activities, bulk samples must be collected and analyzed for asbestos content.
I appreciate this opportunity to provide my services. Should you have any questions concerning this report, please contact me at (843) 995-5197.
Sincerely, Asbestos Building Inspector (SCDHEC #BI-00738)
3.0 EXECUTIVE SUMMARY
1.1 Scope and Purpose
Mr. Sam LoFaso with Horry County Government requested this assessment for the structure located at 873 Pint Circle in Longs, South Carolina. Based on information obtained from you, the structure is scheduled for demolition. The purpose of this assessment was to identify asbestos containing materials (ACMs) prior to demolition.
The inspection was completed in accordance with procedures specified in SCDHEC regulation 61.86.1 along with Occupational Safety and Health Administration (OSHA) regulation 29 Code of the Federal Regulations (CFR) 1926. The representative bulk samples collected were analyzed by a National Voluntary Laboratory Accreditation Program (NVLAP) certified laboratory which is administered by the National Institute of Standards and Technology (NIST). This report has been prepared in accordance with Environmental Protection Agency (EPA) 40 CFR, 763.85(a)(4).
2.1 Facility Conditions
The subject structure is an approximately 1700 square-feet, structure that appears to be comprised of two mobile homes joined with additions. The home is very overgrown with vegetation, the roof and ceilings have fallen in, and any accessible floors were in very poor condition and are fallen in as well. The exterior consists of mostly sheet metal walls with wood walls at the addition areas, with an asphalt shingled roof.
The interior was not very accessible; however, we were able to make it partially inside the rear portion as well as at the front door of the front portion. It appears that the interior is mostly wood panelled walls, drywall ceiling, carpeting, and vinyl sheet floor. Every attempt was made to sample all suspect building materials even though the majority of the structure is inaccessible.
Suspect materials sampled during this inspection include sheet floor, mastic, drywall with associated joint compound, shingles, and tarpaper.
The possibility exists that suspect materials were undetected in inaccessible areas such as areas deemed unsafe to enter, underneath or behind contents of units, behind exterior veneer, pipe chases, or wall voids. If additional suspect materials not included in this report are discovered during demolition, bulk samples should be collected and analyzed for asbestos content.
3.1 Findings and Conclusions
The EPA and SCDHEC define materials as asbestos containing if an asbestos content >1% is identified in a representative sample. No asbestos >1% was detected in the following suspect materials collected and analyzed:
Material ID Material Regulatory Result Highest Analytical Result Est. Quantity There are no homogenous materials for this project that have tested positive containing asbestos
A copy of this report along with a demolition application should be submitted to SCDHEC at least 10 working days prior to any demolition activities. Additionally, a copy of this report should be provided to the contractors to assist with compliance with applicable State and Federal regulations.
The results presented in this report are indicative of conditions during the time of the assessment. The information provided in this report should not be used as a bidding document and field conditions and quantities should be verified.
4.0 ASBESTOS ASSESSMENT DATA
The assessment was performed by observing and sampling suspect ACMs in the unit prior to the scheduled renovations. Representative bulk samples were then extracted, recorded on a chain of custody, and submitted to Eurofins/CEI Labs of Cary, North Carolina for laboratory analysis. The samples were tested via Polarized Light Microscopy (PLM); however, SCDHEC requires a Transmission Electron Microscopy (TEM) test be performed for all non-friable organically bound material found negative via PLM.
The following tables exhibits the suspect material sampled, location, quantity of material sampled, condition of material, potential for future disturbance, and laboratory analysis.
All Materials Sampled
Material Id
Material Space Name
Quantity Material Category
Current Condition
Friability Damage Potential
Physical Assessment Category
Sheet
Floor/Mastic Rear
Structure 120 sq.
ft.
Miscellaneous
Significantly Damaged
Category I Nonfriable
Potential for
Significant Damage
002 Sheet Floor Front
Structure 120 sq.
ft.
Miscellaneous
Significantly Damaged
Category I Nonfriable
Potential for
Significant Damage
Drywall/Joint
Compound Rear
Ceiling 700 sq.
ft.
Surfacing Material
Significantly Damaged
Friable
(RACM)
Potential for
Significant Damage
Drywall/Joint
Compound Front
Ceiling 520 sq.
ft.
Surfacing Material
Significantly Damaged
Friable
(RACM)
Potential for
Significant Damage
005 Shingle/Tarpaper Roof 1900 sq.
ft.
Miscellaneous
Significantly Damaged
Category I Nonfriable
Potential for
Significant Damage
Sample Results
Sample # Material % Mineral Type Regulatory Result Analysis Type
001A Beige Sheet Floor ND ND Tested Negative by Lab PLM Green Sheet Floor ND ND Tested Negative by Lab PLM
Yellow Mastic ND ND Tested Negative by Lab PLM
001B Beige Sheet Floor ND ND Tested Negative by Lab PLM Green Sheet Floor ND ND Tested Negative by Lab PLM
Yellow Mastic ND ND Tested Negative by Lab PLM
001C
Beige Sheet Floor ND ND Tested Negative by Lab TEM Yellow Mastic ND ND Tested Negative by Lab TEM
Green Sheet Floor ND ND Tested Negative by Lab TEM Yellow Mastic ND ND Tested Negative by Lab TEM
002A Off-white, Gray, Maroon Sheet Floor ND ND Tested Negative by Lab PLM 002B Off-white, Gray, Maroon Sheet Floor ND ND Tested Negative by Lab PLM 002C Off-white, Gray, Maroon Sheet Floor ND ND Tested Negative by Lab TEM
003A White Joint Compound ND ND Tested Negative by Lab PLM
White Drywall ND ND Tested Negative by Lab PLM
003B White Joint Compound ND ND Tested Negative by Lab PLM
White Drywall ND ND Tested Negative by Lab PLM
003C White Joint Compound ND ND Tested Negative by Lab PLM
White Drywall ND ND Tested Negative by Lab PLM
004A White Joint Compound ND ND Tested Negative by Lab PLM
White Drywall ND ND Tested Negative by Lab PLM
004B White Joint Compound ND ND Tested Negative by Lab PLM
White Drywall ND ND Tested Negative by Lab PLM
004C White Joint Compound ND ND Tested Negative by Lab PLM
White Drywall ND ND Tested Negative by Lab PLM
005A Gray Shingle ND ND Tested Negative by Lab PLM
Black Tarpaper ND ND Tested Negative by Lab PLM
005B Gray Shingle ND ND Tested Negative by Lab PLM
Black Tarpaper ND ND Tested Negative by Lab PLM
005C Gray Shingle ND ND Tested Negative by Lab TEM
Black Tarpaper ND ND Tested Negative by Lab TEM
Please understand that quantities are estimated and should not be used for bidding purposes. Field conditions should be verified prior to bidding.
Site location plan and sample location plan is identified as Figures 1 and 2 in Appendix 1 of this report, photographs are in Appendix 2, laboratory results are in Appendix 3, and license is in Appendix 4.
5.0 CONCLUSIONS
The EPA and SCDHEC define materials as asbestos containing if an asbestos content >1% is detected in a representative sample. No asbestos >1 % was detected in the suspect materials sampled and analyzed for the structure located at 873 Pint Circle in Longs, South Carolina:
Material ID Material Regulatory Result Highest Analytical Result Est. Quantity There are no homogenous materials for this project that have tested positive containing asbestos
A copy of this report along with a demolition application should be submitted to SCDHEC at least 10 working days prior to any demolition activities. Additionally, a copy of this report should be provided to the contractors to assist with compliance with applicable State and Federal regulations.
The possibility exists that suspect materials were undetected in inaccessible areas such as areas deemed unsafe to enter, behind exterior veneer, pipe chases, or wall voids. If additional suspect materials not included in this report are discovered during renovations, bulk samples should be collected and analyzed for asbestos content.
APPENDIX 1
Site Location Plan and Sample Location Plan
Site Location Plan 873 Pint Cir Longs, SC Project # - 2023-01-107
Scale: Not to Scale Reviewed By: DS Date: 4/4/23 Source: N/A
Figure 1
Subject Property
Asbestos Sample Location Plan 873 Pint Cir Longs, SC Project # - 2023-01-107
Figure 2 Scale: Not to Scale Reviewed By: DS Date: 4/4/23 Source: N/A
Figure 2
LEGEND
Sample Location
Asbestos Containing Sample Location
005A-B
001A-C 003A-C
002A-C
005C
004A-C
APPENDIX 2
Photographs
Site Photos
Interior Rear Structure Bedroom
Kitchen Rear Structure
Interior Front Structure
Interior Front Structure
Interior
Exterior
APPENDIX 3
Laboratory Results
April 14, 2023
Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
CLIENT PROJECT: 873 Pint Cir
CEI LAB CODE: B237416
Dear Customer:
Enclosed are asbestos analysis results for PLM Bulk samples received at our laboratory on April 4, 2023. The samples were analyzed for asbestos using polarizing light microscopy (PLM) per the EPA 600 Method.
Sample results containing >1% asbestos are considered asbestos-containing materials (ACMs) per EPA regulatory requirements. The detection limit for the EPA 600 Method is <1% asbestos by weight as determined by visual estimation.
Thank you for your business and we look forward to continuing good relations.
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Tianbao Bai, Ph.D., CIH Laboratory Director
Kind Regards, ASBESTOS ANALYTICAL REPORT
By: Polarized Light Microscopy
Prepared for
Asbestos Inspections LLC
CLIENT PROJECT:
LAB CODE:
TEST METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
REPORT DATE:
TOTAL SAMPLES ANALYZED:
# SAMPLES >1% ASBESTOS:
873 Pint Cir
04/14/23
B237416
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Asbestos Report Summary By: POLARIZING LIGHT MICROSCOPY
PROJECT: 873 Pint Cir LAB CODE: B237416
Client ID Lab ID Color Sample Description
ASBESTOS
%Layer
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
001A B2237416.01A Beige Sheet Floor None Detected001A
B2237416.01B Green Sheet Floor None Detected
B2237416.01C Yellow Mastic None Detected
001B B2237416.02A Beige Sheet Floor None Detected001B
B2237416.02B Yellow Mastic None Detected
B2237416.02C Green Sheet Floor None Detected
B2237416.02D Yellow Mastic None Detected
001C B2237416.03A Sample Submitted for TEM Analysis
001C
B2237416.03B Sample Submitted for TEM Analysis
B2237416.03C Sample Submitted for TEM Analysis
B2237416.03D Sample Submitted for TEM Analysis
002A B2237416.04 Off-white,Gray Maroon
Sheet Floor002A
002B B2237416.05 Off-white,Gray Maroon
Sheet Floor002B
002C B2237416.06 Sample Submitted for TEM Analysis
002C
003A Layer 1 B2237416.07 White Joint Compound None Detected003A
Layer 2 B2237416.07 White Drywall None Detected
003B Layer 1 B2237416.08 White Joint Compound None Detected003B
Layer 2 B2237416.08 White Drywall None Detected
003C Layer 1 B2237416.09 White Joint Compound None Detected003C
Layer 2 B2237416.09 White Drywall None Detected
004A Layer 1 B2237416.10 White Joint Compound None Detected004A
Layer 2 B2237416.10 White Drywall None Detected
004B Layer 1 B2237416.11 White Joint Compound None Detected004B
Layer 2 B2237416.11 White Drywall None Detected
004C Layer 1 B2237416.12 White Joint Compound None Detected004C
Layer 2 B2237416.12 White Drywall None Detected
Page 1 of 2730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Asbestos Report Summary
PROJECT: 873 Pint Cir LAB CODE: B237416
Client ID Lab ID Color Sample Description
ASBESTOS
%Layer
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
005A Layer 1 B2237416.13 Gray Shingle None Detected005A
Layer 2 B2237416.13 Black Tarpaper None Detected
005B Layer 1 B2237416.14 Gray Shingle None Detected005B
Layer 2 B2237416.14 Black Tarpaper None Detected
005C Layer 1 B2237416.15 Sample Submitted for TEM Analysis
005C
Layer 2 B2237416.15 Sample Submitted for TEM Analysis
Page 2 of 2730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
ASBESTOS BULK ANALYSIS
Lab Code: B237416 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 873 Pint Cir
Fibrous
Beige Sheet Floor001A
B2237416.01A Heterogeneous
Non-fibrous Bound
No mastic present.
80% 20%
Vinyl Binder
None Detected
Green Sheet FloorB2237416.01B Heterogeneous
Non-fibrous Bound
80% 20%
Vinyl Binder
None Detected
Yellow MasticB2237416.01C Homogeneous
Non-fibrous Bound
100% Mastic None Detected
Beige Sheet Floor001B
B2237416.02A Heterogeneous
Non-fibrous Bound
80% 20%
Vinyl Binder
None Detected
Yellow MasticB2237416.02B Homogeneous
Non-fibrous Bound
100% Mastic None Detected
Green Sheet FloorB2237416.02C Heterogeneous
Non-fibrous Bound
80% 20%
Vinyl Binder
None Detected
Yellow MasticB2237416.02D Homogeneous
Non-fibrous Bound
100% Mastic None Detected
Sample Submitted for TEM Analysis
001C B2237416.03A
Page 1 of 5730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Lab Code: B237416 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 873 Pint Cir
Fibrous
Sample Submitted for TEM Analysis
B2237416.03B
Sample Submitted for TEM Analysis
B2237416.03C
Sample Submitted for TEM Analysis
B2237416.03D
Off-white,Gray Maroon
Sheet Floor002A B2237416.04
Heterogeneous
Non-fibrous Bound
80% 20%
Binder Binder
Off-white,Gray Maroon
Sheet Floor002B B2237416.05
Heterogeneous
Non-fibrous Bound
80% 20%
Binder Binder
Sample Submitted for TEM Analysis
002C B2237416.06
White 003A
B2237416.07
Heterogeneous
Non-fibrous Bound
60% 35% 5%
Binder Calc Carb Paint
None Detected Layer 1
Joint Compound
White Drywall
B2237416.07 15%Heterogeneous
Fibrous Bound
85%Cellulose Gypsum None DetectedLayer 2
White 003B
B2237416.08
Heterogeneous
Non-fibrous Bound
60% 35% 5%
Binder Calc Carb Paint
None Detected Layer 1
Joint Compound
Page 2 of 5730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Lab Code: B237416 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 873 Pint Cir
Fibrous
White Drywall
B2237416.08 15%Heterogeneous
Fibrous Bound
85%Cellulose Gypsum None DetectedLayer 2
White 003C
B2237416.09
Heterogeneous
Non-fibrous Bound
60% 35% 5%
Binder Calc Carb Paint
None Detected Layer 1
Joint Compound
White Drywall
B2237416.09 15%Heterogeneous
Fibrous Bound
85%Cellulose Gypsum None DetectedLayer 2
White 004A
B2237416.10
Heterogeneous
Non-fibrous Bound
60% 35% 5%
Binder Calc Carb Paint
None Detected Layer 1
Joint Compound
White Drywall
B2237416.10 15%Heterogeneous
Fibrous Bound
85%Cellulose Gypsum None DetectedLayer 2
White 004B
B2237416.11
Heterogeneous
Non-fibrous Bound
60% 35% 5%
Binder Calc Carb Paint
None Detected Layer 1
Joint Compound
White Drywall
B2237416.11 15%Heterogeneous
Fibrous Bound
85%Cellulose Gypsum None DetectedLayer 2
Page 3 of 5730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Lab Code: B237416 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 873 Pint Cir
Fibrous
White 004C
B2237416.12
Heterogeneous
Non-fibrous Bound
60% 35% 5%
Binder Calc Carb Paint
None Detected Layer 1
Joint Compound
White Drywall
B2237416.12 15%Heterogeneous
Fibrous Bound
85%Cellulose Gypsum None DetectedLayer 2
Gray 005A
B2237416.13
30%Heterogeneous
Fibrous Bound
60% 10%
Fiberglass Tar Gravel
None Detected Layer 1
Shingle
Black Tarpaper
B2237416.13 70%Homogeneous
Fibrous Bound
30%Cellulose Tar None DetectedLayer 2
Gray 005B
B2237416.14
30%Heterogeneous
Fibrous Bound
60% 10%
Fiberglass Tar Gravel
None Detected Layer 1
Shingle
Black Tarpaper
B2237416.14 70%Homogeneous
Fibrous Bound
30%Cellulose Tar None DetectedLayer 2
005C
B2237416.15 Layer 1
Sample Submitted for TEM Analysis
Sample Submitted for TEM AnalysisB2237416.15
Layer 2
Page 4 of 5730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
LEGEND: Non-Anth = Non-Asbestiform Anthophyllite Non-Trem = Non-Asbestiform Tremolite Calc Carb = Calcium Carbonate
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
REPORTING LIMIT: <1% by visual estimation
REPORTING LIMIT FOR POINT COUNTS: 0.25% by 400 Points or 0.1% by 1,000 Points
REGULATORY LIMIT: >1% by weight
Due to the limitations of the EPA 600 method, nonfriable organically bound materials (NOBs) such as vinyl floor tiles can be difficult to analyze via polarized light microscopy (PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request.
This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results.
Interpretation of the analytical results is the sole responsibility of the client. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.
Information provided by customer includes customer sample ID and sample description.
ANALYST: APPROVED BY:
Tianbao Bai, Ph.D., CIH Laboratory Director
Ryan Steele
April 18, 2023
Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
CLIENT PROJECT: 873 Pint Cir
LAB CODE: T230876
Dear Customer:
Enclosed are asbestos analysis results for TEM bulk samples received at our laboratory on April 11, 2023. The samples were analyzed for asbestos using transmission electron microscopy (TEM) per Chatfield/EPA 600/R-93/116 Sec. 2.5.5.1 method.
Sample results containing > 1% asbestos are considered asbestos-containing materials (ACMs) per the EPA regulatory requirements. The detection limit for the TEM Chatfield/EPA 600/R-93/116 Sec. 2.5.5.1 method is <1% depending on the processed weight and constituents of the sample.
Thank you for your business and we look forward to continuing good relations.
Tianbao Bai, Ph.D., CIH Laboratory Director
Kind Regards, ASBESTOS ANALYTICAL REPORT
By: Transmission Electron Microscopy
Prepared for
Asbestos Inspections LLC
CLIENT PROJECT:
LAB CODE:
TEST METHOD: Bulk Chatfield EPA 600 / R93 / 116 Sec. 2.5.5.1
REPORT DATE:
873 Pint Cir
04/18/23
T230876
By: TRANSMISSION ELECTRON MICROSCOPY
Lab Code: T230876 Date Received: 04-11-23 Date Analyzed: 04-17-23 Date Reported: 04-18-23
Client ID Lab ID
Material Description
TEM BULK CHATFIELD / EPA 600 / R93 / 116 Sec. 2.5.5.1
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 873 Pint Cir
Sample Weight
(g)
Organic Material
Acid Soluble Material
Acid Insoluble Material
Asbestos
T57907 001C Beige Sheet Floor 0.291 45.4 52.9 1.7 None
Detected
T57908 001C Yellow Mastic 0-25.35 0 100 0 <1%Insufficient
T57909 001C Green Sheet Floor 0.343 47.2 51 1.8 None
Detected
T57910 001C Yellow Mastic 0.164 35.4 36.6 28 None
Detected
T57911 002C Sheet Floor 0.246 64.2 28 7.8 None
Detected
T57912 005C Shingle 0.492 25.6 60.2 14.2 None
Detected
T57913 005C Tarpaper 0.662 96.8 1.7 1.5 None
Detected
LEGEND: None
METHOD: CHATFIELD & EPA/600/R-93/116 Sec. 2.5.5.1
LIMIT OF DETECTION: Varies with the weight and constituents of the sample (<1%)
REGULATORY LIMIT: >1% by weight
This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI (ECEI). ECEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results.
Interpretation of the analytical results is the sole responsibility of the client. Estimated measurement of uncertainty is available on request and in compliance with regulatory requirements. Samples were received in acceptable condition unless otherwise noted.
Information provided by customer includes customer sample ID, location, volume and area as well as date and time of sampling.
ECEI recommends between 0.20 and 0.50 grams of sample material for TEM bulk analysis.
Any weight below 0.10 grams is considered below protocol guidelines.
**Indicates sample weight below 0.05 grams and is considered insufficient for quantitative analysis.
ANALYST: APPROVED BY:
Tianbao Bai, Ph.D., CIH Laboratory Director
Stacy Ulrich