This document is an Asbestos Inspection Report prepared by Asbestos Inspections, LLC for Horry County Government, specifically for a property located at 873 Pint Circle in Longs, South Carolina. The inspection was conducted on April 3, 2023, and the report was prepared on April 20, 2023, in accordance with SCDHEC regulation 61-86.1 and OSHA regulation 29 CFR 1926. The purpose of the inspection was to identify asbestos-containing materials (ACMs) prior to the scheduled demolition of the structure, which appears to be comprised of two mobile homes joined with additions and is approximately 1,700 square feet.

The laboratory analysis, conducted by Eurofins/CEI Labs using Polarized Light Microscopy (PLM) and Transmission Electron Microscopy (TEM), found no asbestos-containing materials exceeding the 1% threshold in any of the sampled materials, including sheet floor, mastic, drywall, joint compound, shingles, and tarpaper. The structure was noted to be in significantly damaged condition, with overgrown vegetation, fallen roofs and ceilings, and partially inaccessible interior spaces. The report recommends that if additional suspect materials are discovered during demolition, they should be sampled and analyzed for asbestos content, and a copy of the report should be submitted to SCDHEC at least 10 working days prior to any demolition activities.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASBESTOS INSPECTION REPORT

873 Pint Circle

Longs, South Carolina Asbestos Inspections, LLC Project # 2023-01-107

Performed in general accordance with SCDHEC regulation 61-86.1 along with OSHA regulation 29 CFR 1926

Assessment Completed by:

Asbestos Inspections, LLC 4686 Pee Dee Highway

Conway, South Carolina 29527

(843) 995-5197

Dawn Schoolcraft

SCDHEC ID# BI-00738

Assessment Completed For:

Mr. Sam LoFaso with Horry County Government 1515 Fourth Avenue

Conway, South Carolina 29526

Inspection Completed On – April 3, 2023 Report Prepared On – April 20, 2023

Asbestos Inspection Report

Project Number – 2023-01-107 April 20, 2023

TABLE OF CONTENTS

1.0 SIGNATURE PAGE

2.0 COVER LETTER

3.0 EXECUTIVE SUMMARY

1.1 Scope and Purpose

2.1 Facility Conditions

3.1 Findings and Conclusions

4.0 ASBESTOS ASSESSMENT DATA

5.0 CONCLUSIONS

Appendix 1- Site Location Plan and Sample Location Plan Appendix 2- Photographs Appendix 3- Laboratory Results Appendix 4- License

1.0 SIGNATURE PAGE

This report has been performed at the request of Mr. Sam LoFaso with Horry County Government. The inspection was conducted by Mrs. Dawn Schoolcraft with Asbestos Inspections, LLC on April 03, 2023.

The report was prepared and reviewed by the undersigned inspector.

Inspection Performed by: SCDEHC# Signature Date

Dawn Schoolcraft BI-00738 Dawn Schoolcraft April 03, 2023

Report Prepared by:

Dawn Schoolcraft BI-00738 Dawn Schoolcraft April 20, 2023

Report Reviewed by:

Dawn Schoolcraft BI-00738 Dawn Schoolcraft April 20, 2023

2.0 COVER LETTER

Mr. Sam LoFaso with Horry County Government 1515 Fourth Avenue Conway, South Carolina 29526

Subject:

Asbestos Inspection Report 873 Pint Circle Longs, South Carolina 29568 Asbestos Inspections, LLC Project # 2023-01-107

Asbestos Inspections, LLC has completed an Asbestos Assessment and Inspection for the structure located at 873 Pint Circle, in Longs, South Carolina. The inspection was completed on April 03, 2023 by a South Carolina Department of Health and Environmental Control (SCDHEC) building inspector.

The following report summarizes the project background, assessment procedures, results, and conclusions. The results presented in this report are indicative of conditions during the time of the inspection and of the specific areas outlined. The information provided in this report should not be used as a bidding document and field conditions should be verified. Should suspect building materials, not included within this report, be identified or impacted during the destructive activities, bulk samples must be collected and analyzed for asbestos content.

I appreciate this opportunity to provide my services. Should you have any questions concerning this report, please contact me at (843) 995-5197.

Sincerely, Asbestos Building Inspector (SCDHEC #BI-00738)

3.0 EXECUTIVE SUMMARY

1.1 Scope and Purpose

Mr. Sam LoFaso with Horry County Government requested this assessment for the structure located at 873 Pint Circle in Longs, South Carolina. Based on information obtained from you, the structure is scheduled for demolition. The purpose of this assessment was to identify asbestos containing materials (ACMs) prior to demolition.

The inspection was completed in accordance with procedures specified in SCDHEC regulation 61.86.1 along with Occupational Safety and Health Administration (OSHA) regulation 29 Code of the Federal Regulations (CFR) 1926. The representative bulk samples collected were analyzed by a National Voluntary Laboratory Accreditation Program (NVLAP) certified laboratory which is administered by the National Institute of Standards and Technology (NIST). This report has been prepared in accordance with Environmental Protection Agency (EPA) 40 CFR, 763.85(a)(4).

2.1 Facility Conditions

The subject structure is an approximately 1700 square-feet, structure that appears to be comprised of two mobile homes joined with additions. The home is very overgrown with vegetation, the roof and ceilings have fallen in, and any accessible floors were in very poor condition and are fallen in as well. The exterior consists of mostly sheet metal walls with wood walls at the addition areas, with an asphalt shingled roof.

The interior was not very accessible; however, we were able to make it partially inside the rear portion as well as at the front door of the front portion. It appears that the interior is mostly wood panelled walls, drywall ceiling, carpeting, and vinyl sheet floor. Every attempt was made to sample all suspect building materials even though the majority of the structure is inaccessible.

Suspect materials sampled during this inspection include sheet floor, mastic, drywall with associated joint compound, shingles, and tarpaper.

The possibility exists that suspect materials were undetected in inaccessible areas such as areas deemed unsafe to enter, underneath or behind contents of units, behind exterior veneer, pipe chases, or wall voids. If additional suspect materials not included in this report are discovered during demolition, bulk samples should be collected and analyzed for asbestos content.

3.1 Findings and Conclusions

The EPA and SCDHEC define materials as asbestos containing if an asbestos content >1% is identified in a representative sample. No asbestos >1% was detected in the following suspect materials collected and analyzed:

Material ID Material Regulatory Result Highest Analytical Result Est. Quantity There are no homogenous materials for this project that have tested positive containing asbestos

A copy of this report along with a demolition application should be submitted to SCDHEC at least 10 working days prior to any demolition activities. Additionally, a copy of this report should be provided to the contractors to assist with compliance with applicable State and Federal regulations.

The results presented in this report are indicative of conditions during the time of the assessment. The information provided in this report should not be used as a bidding document and field conditions and quantities should be verified.

4.0 ASBESTOS ASSESSMENT DATA

The assessment was performed by observing and sampling suspect ACMs in the unit prior to the scheduled renovations. Representative bulk samples were then extracted, recorded on a chain of custody, and submitted to Eurofins/CEI Labs of Cary, North Carolina for laboratory analysis. The samples were tested via Polarized Light Microscopy (PLM); however, SCDHEC requires a Transmission Electron Microscopy (TEM) test be performed for all non-friable organically bound material found negative via PLM.

The following tables exhibits the suspect material sampled, location, quantity of material sampled, condition of material, potential for future disturbance, and laboratory analysis.

All Materials Sampled

Material Id

Material Space Name

Quantity Material Category

Current Condition

Friability Damage Potential

Physical Assessment Category

Sheet

Floor/Mastic Rear

Structure 120 sq.

ft.

Miscellaneous

Significantly Damaged

Category I Nonfriable

Potential for

Significant Damage

002 Sheet Floor Front

Structure 120 sq.

ft.

Miscellaneous

Significantly Damaged

Category I Nonfriable

Potential for

Significant Damage

Drywall/Joint

Compound Rear

Ceiling 700 sq.

ft.

Surfacing Material

Significantly Damaged

Friable

(RACM)

Potential for

Significant Damage

Drywall/Joint

Compound Front

Ceiling 520 sq.

ft.

Surfacing Material

Significantly Damaged

Friable

(RACM)

Potential for

Significant Damage

005 Shingle/Tarpaper Roof 1900 sq.

ft.

Miscellaneous

Significantly Damaged

Category I Nonfriable

Potential for

Significant Damage

Sample Results

Sample # Material % Mineral Type Regulatory Result Analysis Type

001A Beige Sheet Floor ND ND Tested Negative by Lab PLM Green Sheet Floor ND ND Tested Negative by Lab PLM

Yellow Mastic ND ND Tested Negative by Lab PLM

001B Beige Sheet Floor ND ND Tested Negative by Lab PLM Green Sheet Floor ND ND Tested Negative by Lab PLM

Yellow Mastic ND ND Tested Negative by Lab PLM

001C

Beige Sheet Floor ND ND Tested Negative by Lab TEM Yellow Mastic ND ND Tested Negative by Lab TEM

Green Sheet Floor ND ND Tested Negative by Lab TEM Yellow Mastic ND ND Tested Negative by Lab TEM

002A Off-white, Gray, Maroon Sheet Floor ND ND Tested Negative by Lab PLM 002B Off-white, Gray, Maroon Sheet Floor ND ND Tested Negative by Lab PLM 002C Off-white, Gray, Maroon Sheet Floor ND ND Tested Negative by Lab TEM

003A White Joint Compound ND ND Tested Negative by Lab PLM

White Drywall ND ND Tested Negative by Lab PLM

003B White Joint Compound ND ND Tested Negative by Lab PLM

White Drywall ND ND Tested Negative by Lab PLM

003C White Joint Compound ND ND Tested Negative by Lab PLM

White Drywall ND ND Tested Negative by Lab PLM

004A White Joint Compound ND ND Tested Negative by Lab PLM

White Drywall ND ND Tested Negative by Lab PLM

004B White Joint Compound ND ND Tested Negative by Lab PLM

White Drywall ND ND Tested Negative by Lab PLM

004C White Joint Compound ND ND Tested Negative by Lab PLM

White Drywall ND ND Tested Negative by Lab PLM

005A Gray Shingle ND ND Tested Negative by Lab PLM

Black Tarpaper ND ND Tested Negative by Lab PLM

005B Gray Shingle ND ND Tested Negative by Lab PLM

Black Tarpaper ND ND Tested Negative by Lab PLM

005C Gray Shingle ND ND Tested Negative by Lab TEM

Black Tarpaper ND ND Tested Negative by Lab TEM

Please understand that quantities are estimated and should not be used for bidding purposes. Field conditions should be verified prior to bidding.

Site location plan and sample location plan is identified as Figures 1 and 2 in Appendix 1 of this report, photographs are in Appendix 2, laboratory results are in Appendix 3, and license is in Appendix 4.

5.0 CONCLUSIONS

The EPA and SCDHEC define materials as asbestos containing if an asbestos content >1% is detected in a representative sample. No asbestos >1 % was detected in the suspect materials sampled and analyzed for the structure located at 873 Pint Circle in Longs, South Carolina:

Material ID Material Regulatory Result Highest Analytical Result Est. Quantity There are no homogenous materials for this project that have tested positive containing asbestos

A copy of this report along with a demolition application should be submitted to SCDHEC at least 10 working days prior to any demolition activities. Additionally, a copy of this report should be provided to the contractors to assist with compliance with applicable State and Federal regulations.

The possibility exists that suspect materials were undetected in inaccessible areas such as areas deemed unsafe to enter, behind exterior veneer, pipe chases, or wall voids. If additional suspect materials not included in this report are discovered during renovations, bulk samples should be collected and analyzed for asbestos content.

APPENDIX 1

Site Location Plan and Sample Location Plan

Site Location Plan 873 Pint Cir Longs, SC Project # - 2023-01-107

Scale: Not to Scale Reviewed By: DS Date: 4/4/23 Source: N/A

Figure 1

Subject Property

Asbestos Sample Location Plan 873 Pint Cir Longs, SC Project # - 2023-01-107

Figure 2 Scale: Not to Scale Reviewed By: DS Date: 4/4/23 Source: N/A

Figure 2

LEGEND

Sample Location

Asbestos Containing Sample Location

005A-B

001A-C 003A-C

002A-C

005C

004A-C

APPENDIX 2

Photographs

Site Photos

Interior Rear Structure Bedroom

Kitchen Rear Structure

Interior Front Structure

Interior Front Structure

Interior

Exterior

APPENDIX 3

Laboratory Results

April 14, 2023

Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527

CLIENT PROJECT: 873 Pint Cir

CEI LAB CODE: B237416

Dear Customer:

Enclosed are asbestos analysis results for PLM Bulk samples received at our laboratory on April 4, 2023. The samples were analyzed for asbestos using polarizing light microscopy (PLM) per the EPA 600 Method.

Sample results containing >1% asbestos are considered asbestos-containing materials (ACMs) per EPA regulatory requirements. The detection limit for the EPA 600 Method is <1% asbestos by weight as determined by visual estimation.

Thank you for your business and we look forward to continuing good relations.

730 SE Maynard Road • Cary, NC 27511 • 919.481.1413

Tianbao Bai, Ph.D., CIH Laboratory Director

Kind Regards, ASBESTOS ANALYTICAL REPORT

By: Polarized Light Microscopy

Prepared for

Asbestos Inspections LLC

CLIENT PROJECT:

LAB CODE:

TEST METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

REPORT DATE:

TOTAL SAMPLES ANALYZED:

# SAMPLES >1% ASBESTOS:

873 Pint Cir

04/14/23

B237416

730 SE Maynard Road • Cary, NC 27511 • 919.481.1413

Asbestos Report Summary By: POLARIZING LIGHT MICROSCOPY

PROJECT: 873 Pint Cir LAB CODE: B237416

Client ID Lab ID Color Sample Description

ASBESTOS

%Layer

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

001A B2237416.01A Beige Sheet Floor None Detected001A

B2237416.01B Green Sheet Floor None Detected

B2237416.01C Yellow Mastic None Detected

001B B2237416.02A Beige Sheet Floor None Detected001B

B2237416.02B Yellow Mastic None Detected

B2237416.02C Green Sheet Floor None Detected

B2237416.02D Yellow Mastic None Detected

001C B2237416.03A Sample Submitted for TEM Analysis

001C

B2237416.03B Sample Submitted for TEM Analysis

B2237416.03C Sample Submitted for TEM Analysis

B2237416.03D Sample Submitted for TEM Analysis

002A B2237416.04 Off-white,Gray Maroon

Sheet Floor002A

002B B2237416.05 Off-white,Gray Maroon

Sheet Floor002B

002C B2237416.06 Sample Submitted for TEM Analysis

002C

003A Layer 1 B2237416.07 White Joint Compound None Detected003A

Layer 2 B2237416.07 White Drywall None Detected

003B Layer 1 B2237416.08 White Joint Compound None Detected003B

Layer 2 B2237416.08 White Drywall None Detected

003C Layer 1 B2237416.09 White Joint Compound None Detected003C

Layer 2 B2237416.09 White Drywall None Detected

004A Layer 1 B2237416.10 White Joint Compound None Detected004A

Layer 2 B2237416.10 White Drywall None Detected

004B Layer 1 B2237416.11 White Joint Compound None Detected004B

Layer 2 B2237416.11 White Drywall None Detected

004C Layer 1 B2237416.12 White Joint Compound None Detected004C

Layer 2 B2237416.12 White Drywall None Detected

Page 1 of 2730 SE Maynard Road • Cary, NC 27511 • 919.481.1413

Asbestos Report Summary

PROJECT: 873 Pint Cir LAB CODE: B237416

Client ID Lab ID Color Sample Description

ASBESTOS

%Layer

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

005A Layer 1 B2237416.13 Gray Shingle None Detected005A

Layer 2 B2237416.13 Black Tarpaper None Detected

005B Layer 1 B2237416.14 Gray Shingle None Detected005B

Layer 2 B2237416.14 Black Tarpaper None Detected

005C Layer 1 B2237416.15 Sample Submitted for TEM Analysis

005C

Layer 2 B2237416.15 Sample Submitted for TEM Analysis

Page 2 of 2730 SE Maynard Road • Cary, NC 27511 • 919.481.1413

ASBESTOS BULK ANALYSIS

Lab Code: B237416 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527

Project: 873 Pint Cir

Fibrous

Beige Sheet Floor001A

B2237416.01A Heterogeneous

Non-fibrous Bound

No mastic present.

80% 20%

Vinyl Binder

None Detected

Green Sheet FloorB2237416.01B Heterogeneous

Non-fibrous Bound

80% 20%

Vinyl Binder

None Detected

Yellow MasticB2237416.01C Homogeneous

Non-fibrous Bound

100% Mastic None Detected

Beige Sheet Floor001B

B2237416.02A Heterogeneous

Non-fibrous Bound

80% 20%

Vinyl Binder

None Detected

Yellow MasticB2237416.02B Homogeneous

Non-fibrous Bound

100% Mastic None Detected

Green Sheet FloorB2237416.02C Heterogeneous

Non-fibrous Bound

80% 20%

Vinyl Binder

None Detected

Yellow MasticB2237416.02D Homogeneous

Non-fibrous Bound

100% Mastic None Detected

Sample Submitted for TEM Analysis

001C B2237416.03A

Page 1 of 5730 SE Maynard Road • Cary, NC 27511 • 919.481.1413

Lab Code: B237416 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527

Project: 873 Pint Cir

Fibrous

Sample Submitted for TEM Analysis

B2237416.03B

Sample Submitted for TEM Analysis

B2237416.03C

Sample Submitted for TEM Analysis

B2237416.03D

Off-white,Gray Maroon

Sheet Floor002A B2237416.04

Heterogeneous

Non-fibrous Bound

80% 20%

Binder Binder

Off-white,Gray Maroon

Sheet Floor002B B2237416.05

Heterogeneous

Non-fibrous Bound

80% 20%

Binder Binder

Sample Submitted for TEM Analysis

002C B2237416.06

White 003A

B2237416.07

Heterogeneous

Non-fibrous Bound

60% 35% 5%

Binder Calc Carb Paint

None Detected Layer 1

Joint Compound

White Drywall

B2237416.07 15%Heterogeneous

Fibrous Bound

85%Cellulose Gypsum None DetectedLayer 2

White 003B

B2237416.08

Heterogeneous

Non-fibrous Bound

60% 35% 5%

Binder Calc Carb Paint

None Detected Layer 1

Joint Compound

Page 2 of 5730 SE Maynard Road • Cary, NC 27511 • 919.481.1413

Lab Code: B237416 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527

Project: 873 Pint Cir

Fibrous

White Drywall

B2237416.08 15%Heterogeneous

Fibrous Bound

85%Cellulose Gypsum None DetectedLayer 2

White 003C

B2237416.09

Heterogeneous

Non-fibrous Bound

60% 35% 5%

Binder Calc Carb Paint

None Detected Layer 1

Joint Compound

White Drywall

B2237416.09 15%Heterogeneous

Fibrous Bound

85%Cellulose Gypsum None DetectedLayer 2

White 004A

B2237416.10

Heterogeneous

Non-fibrous Bound

60% 35% 5%

Binder Calc Carb Paint

None Detected Layer 1

Joint Compound

White Drywall

B2237416.10 15%Heterogeneous

Fibrous Bound

85%Cellulose Gypsum None DetectedLayer 2

White 004B

B2237416.11

Heterogeneous

Non-fibrous Bound

60% 35% 5%

Binder Calc Carb Paint

None Detected Layer 1

Joint Compound

White Drywall

B2237416.11 15%Heterogeneous

Fibrous Bound

85%Cellulose Gypsum None DetectedLayer 2

Page 3 of 5730 SE Maynard Road • Cary, NC 27511 • 919.481.1413

Lab Code: B237416 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527

Project: 873 Pint Cir

Fibrous

White 004C

B2237416.12

Heterogeneous

Non-fibrous Bound

60% 35% 5%

Binder Calc Carb Paint

None Detected Layer 1

Joint Compound

White Drywall

B2237416.12 15%Heterogeneous

Fibrous Bound

85%Cellulose Gypsum None DetectedLayer 2

Gray 005A

B2237416.13

30%Heterogeneous

Fibrous Bound

60% 10%

Fiberglass Tar Gravel

None Detected Layer 1

Shingle

Black Tarpaper

B2237416.13 70%Homogeneous

Fibrous Bound

30%Cellulose Tar None DetectedLayer 2

Gray 005B

B2237416.14

30%Heterogeneous

Fibrous Bound

60% 10%

Fiberglass Tar Gravel

None Detected Layer 1

Shingle

Black Tarpaper

B2237416.14 70%Homogeneous

Fibrous Bound

30%Cellulose Tar None DetectedLayer 2

005C

B2237416.15 Layer 1

Sample Submitted for TEM Analysis

Sample Submitted for TEM AnalysisB2237416.15

Layer 2

Page 4 of 5730 SE Maynard Road • Cary, NC 27511 • 919.481.1413

LEGEND: Non-Anth = Non-Asbestiform Anthophyllite Non-Trem = Non-Asbestiform Tremolite Calc Carb = Calcium Carbonate

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

REPORTING LIMIT: <1% by visual estimation

REPORTING LIMIT FOR POINT COUNTS: 0.25% by 400 Points or 0.1% by 1,000 Points

REGULATORY LIMIT: >1% by weight

Due to the limitations of the EPA 600 method, nonfriable organically bound materials (NOBs) such as vinyl floor tiles can be difficult to analyze via polarized light microscopy (PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request.

This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results.

Interpretation of the analytical results is the sole responsibility of the client. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.

Information provided by customer includes customer sample ID and sample description.

ANALYST: APPROVED BY:

Tianbao Bai, Ph.D., CIH Laboratory Director

Ryan Steele

April 18, 2023

Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527

CLIENT PROJECT: 873 Pint Cir

LAB CODE: T230876

Dear Customer:

Enclosed are asbestos analysis results for TEM bulk samples received at our laboratory on April 11, 2023. The samples were analyzed for asbestos using transmission electron microscopy (TEM) per Chatfield/EPA 600/R-93/116 Sec. 2.5.5.1 method.

Sample results containing > 1% asbestos are considered asbestos-containing materials (ACMs) per the EPA regulatory requirements. The detection limit for the TEM Chatfield/EPA 600/R-93/116 Sec. 2.5.5.1 method is <1% depending on the processed weight and constituents of the sample.

Thank you for your business and we look forward to continuing good relations.

Tianbao Bai, Ph.D., CIH Laboratory Director

Kind Regards, ASBESTOS ANALYTICAL REPORT

By: Transmission Electron Microscopy

Prepared for

Asbestos Inspections LLC

CLIENT PROJECT:

LAB CODE:

TEST METHOD: Bulk Chatfield EPA 600 / R93 / 116 Sec. 2.5.5.1

REPORT DATE:

873 Pint Cir

04/18/23

T230876

By: TRANSMISSION ELECTRON MICROSCOPY

Lab Code: T230876 Date Received: 04-11-23 Date Analyzed: 04-17-23 Date Reported: 04-18-23

Client ID Lab ID

Material Description

TEM BULK CHATFIELD / EPA 600 / R93 / 116 Sec. 2.5.5.1

Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527

Project: 873 Pint Cir

Sample Weight

(g)

Organic Material

Acid Soluble Material

Acid Insoluble Material

Asbestos

T57907 001C Beige Sheet Floor 0.291 45.4 52.9 1.7 None

Detected

T57908 001C Yellow Mastic 0-25.35 0 100 0 <1%Insufficient

T57909 001C Green Sheet Floor 0.343 47.2 51 1.8 None

Detected

T57910 001C Yellow Mastic 0.164 35.4 36.6 28 None

Detected

T57911 002C Sheet Floor 0.246 64.2 28 7.8 None

Detected

T57912 005C Shingle 0.492 25.6 60.2 14.2 None

Detected

T57913 005C Tarpaper 0.662 96.8 1.7 1.5 None

Detected

LEGEND: None

METHOD: CHATFIELD & EPA/600/R-93/116 Sec. 2.5.5.1

LIMIT OF DETECTION: Varies with the weight and constituents of the sample (<1%)

REGULATORY LIMIT: >1% by weight

This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI (ECEI). ECEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results.

Interpretation of the analytical results is the sole responsibility of the client. Estimated measurement of uncertainty is available on request and in compliance with regulatory requirements. Samples were received in acceptable condition unless otherwise noted.

Information provided by customer includes customer sample ID, location, volume and area as well as date and time of sampling.

ECEI recommends between 0.20 and 0.50 grams of sample material for TEM bulk analysis.

Any weight below 0.10 grams is considered below protocol guidelines.

**Indicates sample weight below 0.05 grams and is considered insufficient for quantitative analysis.

ANALYST: APPROVED BY:

Tianbao Bai, Ph.D., CIH Laboratory Director

Stacy Ulrich

APPENDIX 4

License

12884, 06/30/2023, North Carolina, Dawn

Schoolcraft

1909008, 09/30/2023, South Carolina, Dawn

LBP-R-I162035-2, 03/16/2024, South Carolina, BI-00738, 06/06/2023, South Carolina, Dawn

File details come from the government source that posted it. Updated .