This document is an Asbestos Inspection Report prepared by Asbestos Inspections, LLC for Horry County Government, specifically for a property located at 537 Woodland Drive in Murrells Inlet, South Carolina. The inspection was conducted on April 3, 2023, and the report was prepared on April 20, 2023, in accordance with SCDHEC regulation 61-86.1 and OSHA regulation 29 CFR 1926. The purpose of the assessment was to identify asbestos-containing materials (ACMs) prior to the planned demolition of the approximately 1,600 square-foot mobile home, which has sustained significant roof damage and is in poor condition.
The laboratory analysis revealed one asbestos-containing material: the black built-up roof on the rear of the structure, which contains 5% chrysotile asbestos across approximately 400 square feet. This material is classified as a Category I Nonfriable material with potential for significant damage. The report recommends that this asbestos-containing material be removed by a properly licensed asbestos abatement contractor, with asbestos air monitoring required during the abatement process. The report also notes that additional suspect materials may exist in inaccessible areas, and if discovered during demolition, those materials should be sampled and analyzed for asbestos content. The inspection was performed by Dawn Schoolcraft (SCDHEC ID# BI-00738) and Mike Schoolcraft (SCDHEC ID# BI-01624) from Asbestos Inspections, LLC.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ASBESTOS INSPECTION REPORT
537 Woodland Drive
Murrells Inlet, South Carolina Asbestos Inspections, LLC Project # 2023-01-111
Performed in general accordance with SCDHEC regulation 61-86.1 along with OSHA regulation 29 CFR 1926
Assessment Completed by:
Asbestos Inspections, LLC 4686 Pee Dee Highway
Conway, South Carolina 29527
(843) 995-5197
Dawn Schoolcraft
SCDHEC ID# BI-00738
Assessment Completed For:
Mr. Sam LoFaso with Horry County Government 1515 Fourth Avenue
Conway, South Carolina 29526
Inspection Completed On – April 3, 2023 Report Prepared On – April 20, 2023
Asbestos Inspection Report
Project Number – 2023-01-111 April 20, 2023
TABLE OF CONTENTS
1.0 SIGNATURE PAGE
2.0 COVER LETTER
3.0 EXECUTIVE SUMMARY
1.1 Scope and Purpose
2.1 Facility Conditions
3.1 Findings and Conclusions
4.0 ASBESTOS ASSESSMENT DATA
5.0 CONCLUSIONS
Appendix 1- Site Location Plan and Sample Location Plan Appendix 2- Photographs Appendix 3- Laboratory Results Appendix 4- License
1.0 SIGNATURE PAGE
This report has been performed at the request of Mr. Sam LoFaso with Horry County Government. The inspection was conducted by Mr. Mike Schoolcraft with Asbestos Inspections, LLC on April 03, 2023. The report was prepared and reviewed by the undersigned inspector.
Inspection Performed by: SCDEHC# Signature Date
Mike Schoolcraft BI-01624 Mike Schoolcraft April 03, 2023
Report Prepared by:
Dawn Schoolcraft BI-00738 Dawn Schoolcraft April 20, 2023
Report Reviewed by:
Dawn Schoolcraft BI-00738 Dawn Schoolcraft April 20, 2023
2.0 COVER LETTER
Mr. Sam LoFaso with Horry County Government 1515 Fourth Avenue Conway, South Carolina 29526
Subject:
Asbestos Inspection Report 537 Woodland Drive Murrells Inlet, South Carolina 29576 Asbestos Inspections, LLC Project # 2023-01-111
Asbestos Inspections, LLC has completed an Asbestos Assessment and Inspection for the structure located at 537 Woodland Drive, in Murrells Inlet, South Carolina. The inspection was completed on April 03, 2023 by a South Carolina Department of Health and Environmental Control (SCDHEC) building inspector.
The following report summarizes the project background, assessment procedures, results, and conclusions. The results presented in this report are indicative of conditions during the time of the inspection and of the specific areas outlined. The information provided in this report should not be used as a bidding document and field conditions should be verified. Should suspect building materials, not included within this report, be identified or impacted during the destructive activities, bulk samples must be collected and analyzed for asbestos content.
I appreciate this opportunity to provide my services. Should you have any questions concerning this report, please contact me at (843) 995-5197.
Sincerely, Asbestos Building Inspector (SCDHEC #BI-00738)
3.0 EXECUTIVE SUMMARY
1.1 Scope and Purpose
Mr. Sam LoFaso with Horry County Government requested this assessment for the structure located at 537 Woodland Drive in Murrells Inlet, South Carolina. Based on information obtained from you, the structure is scheduled for demolition. The purpose of this assessment was to identify asbestos containing materials (ACMs) prior to demolition.
The inspection was completed in accordance with procedures specified in SCDHEC regulation 61.86.1 along with Occupational Safety and Health Administration (OSHA) regulation 29 Code of the Federal Regulations (CFR) 1926. The representative bulk samples collected were analyzed by a National Voluntary Laboratory Accreditation Program (NVLAP) certified laboratory which is administered by the National Institute of Standards and Technology (NIST). This report has been prepared in accordance with Environmental Protection Agency (EPA) 40 CFR, 763.85(a)(4).
2.1 Facility Conditions
The subject structure is an approximately 1600 square-feet mobile home with a pitched asphalt shingled roof, flat built-up roof on rear, and wood siding. The interior consists of drywall walls and ceilings, carpet, and sheet flooring. The home has sustained major roof damage causing much of the home to be inaccessible
– the floor was very unstable. However, every attempt was made to sample suspect building materials.
Suspect building materials sampled during this inspection include shingles, tarpaper, wall cover, drywall, texture, sheet flooring, and build-up roof.
The possibility exists that suspect materials were undetected in inaccessible areas such as areas deemed unsafe to enter, underneath or behind contents of units, behind exterior veneer, pipe chases, or wall voids. If additional suspect materials not included in this report are discovered during demolition, bulk samples should be collected and analyzed for asbestos content.
3.1 Findings and Conclusions
The EPA and SCDHEC define materials as asbestos containing if an asbestos content >1% is identified in a representative sample. Asbestos >1% was detected in the following suspect materials collected and analyzed:
Material
ID
Material Location Regulatory Result Highest
Analytical Result Est.
Quantity
Black Build-up
Roof
Rear Roof – Very Poor Condition, Friable
Underlying Membrane
Roof
Greater Than 1% Asbestos by Lab (ACM)
5% Chrysotile 400 sq. ft.
The above identified ACM should be removed by a properly licensed asbestos abatement contractor. Asbestos air monitoring will be required during abatement. A copy of this report along with an abatement application should be submitted to SCDHEC at least 10 working days prior to any abatement activities. Additionally, a copy of this report should be provided to the contractors to assist with compliance with applicable State and Federal regulations.
The results presented in this report are indicative of conditions during the time of the assessment. The information provided in this report should not be used as a bidding document and field conditions and quantities should be verified.
4.0 ASBESTOS ASSESSMENT DATA
The assessment was performed by observing and sampling suspect ACMs in the unit prior to the scheduled renovations. Representative bulk samples were then extracted, recorded on a chain of custody, and submitted to Eurofins/CEI Labs of Cary, North Carolina for laboratory analysis. The samples were tested via Polarized Light Microscopy (PLM); however, SCDHEC requires a Transmission Electron Microscopy (TEM) test be performed for all non-friable organically bound material found negative via PLM.
The following tables exhibits the suspect material sampled, location, quantity of material sampled, condition of material, potential for future disturbance, and laboratory analysis.
All Materials Sampled
Id
Material Space Name
Quantity Material Category
Current Condition
Friability Damage Potential
Physical Assessment Category
Shingle/ Tarpaper
Main Roof 1200 sq.
ft.
Miscellaneous
Significantly Damaged
Category I Nonfriable
Potential for
Significant Damage
Wall Cover/
Drywall - Unfinished
Walls Throughout
2500 sq.
ft.
Miscellaneous Significantly
Damaged Friable
(RACM)
Potential for
Significant Damage
Texture/ Drywall
Ceilings Throughout
1600 sq.
ft.
Surfacing Material
Significantly Damaged
Friable
(RACM)
Potential for
Significant Damage
Id
Material Space Name
Quantity Material Category
Current Condition
Friability Damage Potential
Physical Assessment Category
Sheet
Flooring Kitchen and
Laundry 150 sq.
ft.
Miscellaneous
Significantly Damaged
Category I Nonfriable
Potential for
Significant Damage
Built-up Roof –
Underlying Membrane
Roof
Rear Addition / Covered
Porch
400 sq.
ft.
Miscellaneous Significantly
Damaged Category I Nonfriable
Potential for
Significant Damage
Sample Results
Sample # Material % Mineral Type Regulatory Result Analysis Type
001A Black Shingle ND ND Tested Negative by Lab PLM Black Shingle ND ND Tested Negative by Lab PLM
Black Tarpaper ND ND Tested Negative by Lab PLM
001B Black Shingle ND ND Tested Negative by Lab PLM Black Shingle ND ND Tested Negative by Lab PLM
Black Tarpaper ND ND Tested Negative by Lab PLM
001C Black Shingle ND ND Tested Negative by Lab TEM Black Shingle ND ND Tested Negative by Lab TEM
Black Tarpaper ND ND Tested Negative by Lab TEM
002A White Wall Cover ND ND Tested Negative by Lab PLM
White, Brown Drywall ND ND Tested Negative by Lab PLM
002B White Wall Cover ND ND Tested Negative by Lab PLM
White, Brown Drywall ND ND Tested Negative by Lab PLM
002C White Wall Cover ND ND Tested Negative by Lab PLM
White, Brown Drywall ND ND Tested Negative by Lab PLM
003A White Texture ND ND Tested Negative by Lab PLM
White, Brown Drywall ND ND Tested Negative by Lab PLM
003B White Texture ND ND Tested Negative by Lab PLM
White, Brown Drywall ND ND Tested Negative by Lab PLM
003C White Texture ND ND Tested Negative by Lab PLM
White, Brown Drywall ND ND Tested Negative by Lab PLM
003D White Texture ND ND Tested Negative by Lab PLM
White, Brown Drywall ND ND Tested Negative by Lab PLM
003E White Texture ND ND Tested Negative by Lab PLM
White, Brown Drywall ND ND Tested Negative by Lab PLM 004A Off-white Sheet Flooring ND ND Tested Negative by Lab PLM 004B Off-white Sheet Flooring ND ND Tested Negative by Lab PLM 004C Off-white Sheet Flooring ND ND Tested Negative by Lab TEM 005A Black Build-up Roof 5% Chrysotile Greater Than 1% Asbestos by Lab (ACM) PLM 005B Black Build-up Roof -- -- Assumed Positive -- 005C Black Build-up Roof -- -- Assumed Positive --
Please understand that quantities are estimated and should not be used for bidding purposes. Field conditions should be verified prior to bidding.
Site location plan and sample location plan is identified as Figures 1 and 2 in Appendix 1 of this report, photographs are in Appendix 2, laboratory results are in Appendix 3, and license is in Appendix 4.
5.0 CONCLUSIONS
The EPA and SCDHEC define materials as asbestos containing if an asbestos content >1% is detected in a representative sample. Asbestos >1 % was detected in the following suspect materials sampled and analyzed for the structure located at 537 Woodland Drive in Murrells Inlet, South Carolina:
ID
Material Location Regulatory Result Highest
Analytical Result Est.
Quantity
Black Build-up
Roof
Rear Roof – Very Poor Condition, Friable
Underlying Membrane
Roof
Greater Than 1% Asbestos by Lab (ACM)
5% Chrysotile 400 sq. ft.
The above identified ACM should be removed by a properly licensed asbestos abatement contractor. Asbestos air monitoring will be required during abatement. A copy of this report along with an abatement application should be submitted to SCDHEC at least 10 working days prior to any abatement activities. Additionally, a copy of this report should be provided to the contractors to assist with compliance with applicable State and Federal regulations.
The possibility exists that suspect materials were undetected in inaccessible areas such as areas deemed unsafe to enter, behind exterior veneer, pipe chases, or wall voids. If additional suspect materials not included in this report are discovered during renovations, bulk samples should be collected and analyzed for asbestos content.
APPENDIX 1
Site Location Plan and Sample Location Plan
Site Location Plan 537 Woodland Dr Murrells Inlet, SC Project # - 2023-01-111
Scale: Not to Scale Reviewed By: DS Date: 4/4/23 Source: N/A
Figure 1
Subject Property
Asbestos Sample Location Plan 537 Woodland Dr Murrells Inlet, SC Project # - 2023-01-111
Figure 2 Scale: Not to Scale Reviewed By: DS Date: 3/10/23 Source: N/A
Figure 2
LEGEND
Sample Location
Asbestos Containing Sample Location
002A
Laundry
Closet
Bath
Covered Porch / Addition
Kitchen Dining Room
Living Room Master
Bedroom Den
Bedroom
Bath
Porch
002C003A
004A-C
003B
002D-E
002B
003C
001A-C
005A-C
Asbestos containing built-up roof - Approx. 400 sq. ft.
APPENDIX 2
Photographs
Site Photos
Exterior Front
Exterior
Kitchen
Bedroom
Bedroom
Interior
Interior
Living Room
Exterior
Exterior Rear Roof
APPENDIX 3
Laboratory Results
April 14, 2023
Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
CLIENT PROJECT: 537 Woodland Dr
CEI LAB CODE: B237417
Dear Customer:
Enclosed are asbestos analysis results for PLM Bulk samples received at our laboratory on April 4, 2023. The samples were analyzed for asbestos using polarizing light microscopy (PLM) per the EPA 600 Method.
Sample results containing >1% asbestos are considered asbestos-containing materials (ACMs) per EPA regulatory requirements. The detection limit for the EPA 600 Method is <1% asbestos by weight as determined by visual estimation.
Thank you for your business and we look forward to continuing good relations.
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Tianbao Bai, Ph.D., CIH Laboratory Director
Kind Regards, ASBESTOS ANALYTICAL REPORT
By: Polarized Light Microscopy
Prepared for
Asbestos Inspections LLC
CLIENT PROJECT:
LAB CODE:
TEST METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
REPORT DATE:
TOTAL SAMPLES ANALYZED:
# SAMPLES >1% ASBESTOS:
537 Woodland Dr
04/14/23
B237417
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Asbestos Report Summary By: POLARIZING LIGHT MICROSCOPY
PROJECT: 537 Woodland Dr LAB CODE: B237417
Client ID Lab ID Color Sample Description
ASBESTOS
%Layer
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
001A Layer 1 B237417.01A Black Shingle None Detected001A
Layer 2 B237417.01A Black Shingle None Detected
B237417.01B Black Tarpaper None Detected
001B Layer 1 B237417.02A Black Shingle None Detected001B
Layer 2 B237417.02A Black Shingle None Detected
B237417.02B Black Tarpaper None Detected
001C Layer 1 B237417.03A Sample Submitted for TEM Analysis
001C
Layer 2 B237417.03A Sample Submitted for TEM Analysis
B237417.03B Sample Submitted for TEM Analysis
002A Layer 1 B237417.04 White Wall Cover None Detected002A
Layer 2 B237417.04 White,Brown Drywall None Detected
002B Layer 1 B237417.05 White Wall Cover None Detected002B
Layer 2 B237417.05 White,Brown Drywall None Detected
002C Layer 1 B237417.06 White Wall Cover None Detected002C
Layer 2 B237417.06 White,Brown Drywall None Detected
003A Layer 1 B237417.07 White Texture None Detected003A
Layer 2 B237417.07 White,Brown Drywall None Detected
003B Layer 1 B237417.08 White Texture None Detected003B
Layer 2 B237417.08 White,Brown Drywall None Detected
003C Layer 1 B237417.09 White Texture None Detected003C
Layer 2 B237417.09 White,Brown Drywall None Detected
003D Layer 1 B237417.10 White Texture None Detected003D
Layer 2 B237417.10 White,Brown Drywall None Detected
003E Layer 1 B237417.11 White Texture None Detected003E
Layer 2 B237417.11 White,Brown Drywall None Detected
004A B237417.12 Off-white Sheet Flooring None Detected004A
004B B237417.13 Off-white Sheet Flooring None Detected004B
004C B237417.14 Sample Submitted for TEM Analysis
004C
Page 1 of 2730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Asbestos Report Summary
PROJECT: 537 Woodland Dr LAB CODE: B237417
Client ID Lab ID Color Sample Description
ASBESTOS
%Layer
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
005A B237417.15 Black Buildup Roof Chrysotile005A 5% 005B B237417.16 Sample Not Analyzed per COC005B
005C B237417.17 Sample Not Analyzed per COC005C
Page 2 of 2730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
ASBESTOS BULK ANALYSIS
Lab Code: B237417 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 537 Woodland Dr
Fibrous
Black 001A
B237417.01A
50%Heterogeneous
Fibrous Bound
40% 10%
Fiberglass Tar Gravel
None Detected Layer 1
Shingle
Black Shingle
B237417.01A 50%Heterogeneous
Fibrous Bound
40% 10%
Fiberglass Tar Gravel
None DetectedLayer 2
Black TarpaperB237417.01B 70%Heterogeneous
Fibrous Bound
30%Cellulose Tar None Detected
Black 001B
B237417.02A
50%Heterogeneous
Fibrous Bound
40% 10%
Fiberglass Tar Gravel
None Detected Layer 1
Shingle
Black Shingle
B237417.02A 50%Heterogeneous
Fibrous Bound
40% 10%
Fiberglass Tar Gravel
None DetectedLayer 2
Black TarpaperB237417.02B 70%Heterogeneous
Fibrous Bound
30%Cellulose Tar None Detected
001C
B237417.03A Layer 1
Sample Submitted for TEM Analysis
Sample Submitted for TEM AnalysisB237417.03A
Layer 2
Sample Submitted for TEM Analysis
B237417.03B
Page 1 of 5730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Lab Code: B237417 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 537 Woodland Dr
Fibrous
White 002A
B237417.04
100%Homogeneous
Fibrous Loosely Bound
Cellulose None Detected Layer 1
Wall Cover
White,Brown Drywall
B237417.04 20% 2%
Heterogeneous
Fibrous Bound
78%Cellulose Fiberglass
Gypsum None DetectedLayer 2
White 002B
B237417.05
100%Homogeneous
Fibrous Loosely Bound
Cellulose None Detected Layer 1
Wall Cover
White,Brown Drywall
B237417.05 20% 2%
Heterogeneous
Fibrous Bound
78%Cellulose Fiberglass
Gypsum None DetectedLayer 2
White 002C
B237417.06
100%Homogeneous
Fibrous Loosely Bound
Cellulose None Detected Layer 1
Wall Cover
White,Brown Drywall
B237417.06 20% 2%
Heterogeneous
Fibrous Bound
78%Cellulose Fiberglass
Gypsum None DetectedLayer 2
White 003A
B237417.07
5%Heterogeneous
Fibrous Bound
80% 10% 5%
Fiberglass Binder Foam Paint
None Detected Layer 1
Texture
Page 2 of 5730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Lab Code: B237417 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 537 Woodland Dr
Fibrous
White,Brown Drywall
B237417.07 20% 2%
Heterogeneous
Fibrous Bound
78%Cellulose Fiberglass
Gypsum None DetectedLayer 2
White 003B
B237417.08
5%Heterogeneous
Fibrous Bound
80% 10% 5%
Fiberglass Binder Foam Paint
None Detected Layer 1
Texture
White,Brown Drywall
B237417.08 20% 2%
Heterogeneous
Fibrous Bound
78%Cellulose Fiberglass
Gypsum None DetectedLayer 2
White 003C
B237417.09
5%Heterogeneous
Fibrous Bound
80% 10% 5%
Fiberglass Binder Foam Paint
None Detected Layer 1
Texture
White,Brown Drywall
B237417.09 20% 2%
Heterogeneous
Fibrous Bound
78%Cellulose Fiberglass
Gypsum None DetectedLayer 2
White 003D
B237417.10
5%Heterogeneous
Fibrous Bound
80% 10% 5%
Fiberglass Binder Foam Paint
None Detected Layer 1
Texture
White,Brown Drywall
B237417.10 20% 2%
Heterogeneous
Fibrous Bound
78%Cellulose Fiberglass
Gypsum None DetectedLayer 2
Page 3 of 5730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Lab Code: B237417 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 537 Woodland Dr
Fibrous
White 003E
B237417.11
5%Heterogeneous
Fibrous Bound
80% 10% 5%
Fiberglass Binder Foam Paint
None Detected Layer 1
Texture
White,Brown Drywall
B237417.11 20% 2%
Heterogeneous
Fibrous Bound
78%Cellulose Fiberglass
Gypsum None DetectedLayer 2
Off-white Sheet Flooring004A
B237417.12 Homogeneous
Non-fibrous Tightly Bound
80% 20%
Vinyl Foam
None Detected
Off-white Sheet Flooring004B
B237417.13 Homogeneous
Non-fibrous Tightly Bound
80% 20%
Vinyl Foam
None Detected
Sample Submitted for TEM Analysis
004C B237417.14
Black Buildup Roof005A
B237417.15 Heterogeneous
Non-fibrous Bound
95% Tar 5% Chrysotile
Sample Not Analyzed per COC
005B B237417.16
Sample Not Analyzed per COC
005C B237417.17
Page 4 of 5730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
LEGEND: Non-Anth = Non-Asbestiform Anthophyllite Non-Trem = Non-Asbestiform Tremolite Calc Carb = Calcium Carbonate
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
REPORTING LIMIT: <1% by visual estimation
REPORTING LIMIT FOR POINT COUNTS: 0.25% by 400 Points or 0.1% by 1,000 Points
REGULATORY LIMIT: >1% by weight
Due to the limitations of the EPA 600 method, nonfriable organically bound materials (NOBs) such as vinyl floor tiles can be difficult to analyze via polarized light microscopy (PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request.
This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results.
Interpretation of the analytical results is the sole responsibility of the client. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.
Information provided by customer includes customer sample ID and sample description.
ANALYST: APPROVED BY:
Tianbao Bai, Ph.D., CIH Laboratory Director
Nicholas Moore
April 18, 2023
Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
CLIENT PROJECT: 537 Woodland Dr
LAB CODE: T230877
Dear Customer:
Enclosed are asbestos analysis results for TEM bulk samples received at our laboratory on April 11, 2023. The samples were analyzed for asbestos using transmission electron microscopy (TEM) per Chatfield/EPA 600/R-93/116 Sec. 2.5.5.1 method.
Sample results containing > 1% asbestos are considered asbestos-containing materials (ACMs) per the EPA regulatory requirements. The detection limit for the TEM Chatfield/EPA 600/R-93/116 Sec. 2.5.5.1 method is <1% depending on the processed weight and constituents of the sample.
Thank you for your business and we look forward to continuing good relations.
Tianbao Bai, Ph.D., CIH Laboratory Director
Kind Regards, ASBESTOS ANALYTICAL REPORT
By: Transmission Electron Microscopy
Prepared for
Asbestos Inspections LLC
CLIENT PROJECT:
LAB CODE:
TEST METHOD: Bulk Chatfield EPA 600 / R93 / 116 Sec. 2.5.5.1
REPORT DATE:
537 Woodland Dr
04/18/23
T230877
By: TRANSMISSION ELECTRON MICROSCOPY
Lab Code: T230877 Date Received: 04-11-23 Date Analyzed: 04-18-23 Date Reported: 04-18-23
Client ID Lab ID
Material Description
TEM BULK CHATFIELD / EPA 600 / R93 / 116 Sec. 2.5.5.1
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 537 Woodland Dr
Sample Weight
(g)
Organic Material
Acid Soluble Material
Acid Insoluble Material
Asbestos
T57938 001C Black Shingle 0.341 21.7 52.5 25.8 None
Detected
T57939 001C Black Shingle 0.446 18.4 43.3 38.3 None
Detected
T57940 001C Black Tarpaper 0.623 95 2.6 2.4 None
Detected
T57941 004C Off-white Sheet Flooring 0.248 95.2 2.8 2 None
Detected
LEGEND: None
METHOD: CHATFIELD & EPA/600/R-93/116 Sec. 2.5.5.1
LIMIT OF DETECTION: Varies with the weight and constituents of the sample (<1%)
REGULATORY LIMIT: >1% by weight
This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI (ECEI). ECEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results.
Interpretation of the analytical results is the sole responsibility of the client. Estimated measurement of uncertainty is available on request and in compliance with regulatory requirements. Samples were received in acceptable condition unless otherwise noted.
Information provided by customer includes customer sample ID, location, volume and area as well as date and time of sampling.
ECEI recommends between 0.20 and 0.50 grams of sample material for TEM bulk analysis.
Any weight below 0.10 grams is considered below protocol guidelines.
**Indicates sample weight below 0.05 grams and is considered insufficient for quantitative analysis.
ANALYST: APPROVED BY:
Tianbao Bai, Ph.D., CIH Laboratory Director
Stacy Ulrich
APPENDIX 4
License
12884, 06/30/2023, North Carolina, Dawn
Schoolcraft
1909008, 09/30/2023, South Carolina, Dawn
LBP-R-I162035-2, 03/16/2024, South Carolina, BI-00738, 06/06/2023, South Carolina, Dawn
File details come from the government source that posted it. Updated .