2023-24-006_Abatement 5425_279 Freemont Rd Asbestos Report.pdf
PDF 5 MB Posted
- Attached to
- Demolition of Condemned Dwellings (Group 6)
- Solicitation number
- 2023-24-006
- Issued by
- Florence County, South Carolina
About this file
This document is an Asbestos Inspection Report prepared by Asbestos Inspections, LLC for Horry County Government, specifically for a mobile home located at 279 Freemont Road in Longs, South Carolina. The inspection was conducted on April 3, 2023, by Dawn Schoolcraft, a certified asbestos building inspector, in preparation for the property's scheduled demolition. The report follows procedures specified in SCDHEC regulation 61.86.1 and OSHA regulation 29 CFR 1926, with representative bulk samples analyzed by a National Voluntary Laboratory Accreditation Program (NVLAP) certified laboratory.
The comprehensive inspection covered an approximately 840 square-foot mobile home with metal siding and a shingled roof, examining various materials including shingles, tarpaper, sheet flooring, mastic, textured ceiling, drywall, and joint compound. Critically, the laboratory analysis using both Polarized Light Microscopy (PLM) and Transmission Electron Microscopy (TEM) methods found no asbestos-containing materials (ACMs) exceeding the 1% regulatory threshold. The report recommends submitting a copy of the inspection report along with a demolition application to SCDHEC at least 10 working days prior to demolition activities, and providing the report to contractors to ensure compliance with state and federal regulations.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ASBESTOS INSPECTION REPORT
279 Freemont Road
Longs, South Carolina Asbestos Inspections, LLC Project # 2023-01-106
Performed in general accordance with SCDHEC regulation 61-86.1 along with OSHA regulation 29 CFR 1926
Assessment Completed by:
Asbestos Inspections, LLC 4686 Pee Dee Highway
Conway, South Carolina 29527
(843) 995-5197
Dawn Schoolcraft
SCDHEC ID# BI-00738
Assessment Completed For:
Mr. Sam LoFaso with Horry County Government 1515 Fourth Avenue
Conway, South Carolina 29526
Inspection Completed On – April 3, 2023 Report Prepared On – April 20, 2023
Asbestos Inspection Report
Project Number – 2023-01-106 April 20, 2023
TABLE OF CONTENTS
1.0 SIGNATURE PAGE
2.0 COVER LETTER
3.0 EXECUTIVE SUMMARY
1.1 Scope and Purpose
2.1 Facility Conditions
3.1 Findings and Conclusions
4.0 ASBESTOS ASSESSMENT DATA
5.0 CONCLUSIONS
Appendix 1- Site Location Plan and Sample Location Plan Appendix 2- Photographs Appendix 3- Laboratory Results Appendix 4- License
1.0 SIGNATURE PAGE
This report has been performed at the request of Mr. Sam LoFaso with Horry County Government. The inspection was conducted by Mrs. Dawn Schoolcraft with Asbestos Inspections, LLC on April 03, 2023.
The report was prepared and reviewed by the undersigned inspector.
Inspection Performed by: SCDEHC# Signature Date
Dawn Schoolcraft BI-00738 Dawn Schoolcraft April 03, 2023
Report Prepared by:
Dawn Schoolcraft BI-00738 Dawn Schoolcraft April 20, 2023
Report Reviewed by:
Dawn Schoolcraft BI-00738 Dawn Schoolcraft April 20, 2023
2.0 COVER LETTER
Mr. Sam LoFaso with Horry County Government 1515 Fourth Avenue Conway, South Carolina 29526
Subject:
Asbestos Inspection Report 279 Freemont Road Longs, South Carolina 29568 Asbestos Inspections, LLC Project # 2023-01-106
Asbestos Inspections, LLC has completed an Asbestos Assessment and Inspection for the structure located at 279 Freemont Road, in Longs, South Carolina. The inspection was completed on April 03, 2023 by a South Carolina Department of Health and Environmental Control (SCDHEC) building inspector.
The following report summarizes the project background, assessment procedures, results, and conclusions. The results presented in this report are indicative of conditions during the time of the inspection and of the specific areas outlined. The information provided in this report should not be used as a bidding document and field conditions should be verified. Should suspect building materials, not included within this report, be identified or impacted during the destructive activities, bulk samples must be collected and analyzed for asbestos content.
I appreciate this opportunity to provide my services. Should you have any questions concerning this report, please contact me at (843) 995-5197.
Sincerely, Asbestos Building Inspector (SCDHEC #BI-00738)
3.0 EXECUTIVE SUMMARY
1.1 Scope and Purpose
Mr. Sam LoFaso with Horry County Government requested this assessment for the structure located at 279 Freemont Road in Longs, South Carolina. Based on information obtained from you, the structure is scheduled for demolition. The purpose of this assessment was to identify asbestos containing materials (ACMs) prior to demolition.
The inspection was completed in accordance with procedures specified in SCDHEC regulation 61.86.1 along with Occupational Safety and Health Administration (OSHA) regulation 29 Code of the Federal Regulations (CFR) 1926. The representative bulk samples collected were analyzed by a National Voluntary Laboratory Accreditation Program (NVLAP) certified laboratory which is administered by the National Institute of Standards and Technology (NIST). This report has been prepared in accordance with Environmental Protection Agency (EPA) 40 CFR, 763.85(a)(4).
2.1 Facility Conditions
The subject structure is an approximately 840 square-feet, mobile home with metal siding, and a shingled roof. The interior consists of both wood panelled and drywall walls, drywall ceilings, carpet, and sheet flooring. Some flooring and finishes have been removed prior to inspection. Suspect building materials sampled during this inspection include shingles, tarpaper, sheet floor, mastic, textured ceiling, drywall, and joint compound.
The possibility exists that suspect materials were undetected in inaccessible areas such as areas deemed unsafe to enter, underneath or behind contents of units, behind exterior veneer, pipe chases, or wall voids. If additional suspect materials not included in this report are discovered during demolition, bulk samples should be collected and analyzed for asbestos content.
3.1 Findings and Conclusions
The EPA and SCDHEC define materials as asbestos containing if an asbestos content >1% is identified in a representative sample. No asbestos >1% was detected in the suspect materials collected and analyzed:
Material ID Material Regulatory Result Highest Analytical Result Est. Quantity There are no homogenous materials for this project that have tested positive containing asbestos
A copy of this report along with a demolition application should be submitted to SCDHEC at least 10 working days prior to any demolition activities. Additionally, a copy of this report should be provided to the contractors to assist with compliance with applicable State and Federal regulations.
The results presented in this report are indicative of conditions during the time of the assessment. The information provided in this report should not be used as a bidding document and field conditions and quantities should be verified.
4.0 ASBESTOS ASSESSMENT DATA
The assessment was performed by observing and sampling suspect ACMs in the unit prior to the scheduled renovations. Representative bulk samples were then extracted, recorded on a chain of custody, and submitted to Eurofins/CEI Labs of Cary, North Carolina for laboratory analysis. The samples were tested via Polarized Light Microscopy (PLM); however, SCDHEC requires a Transmission Electron Microscopy (TEM) test be performed for all non-friable organically bound material found negative via PLM.
The following tables exhibits the suspect material sampled, location, quantity of material sampled, condition of material, potential for future disturbance, and laboratory analysis.
All Materials Sampled
Material Id
Material Space Name
Quantity Material Category
Current Condition
Friability Damage Potential
Physical Assessment Category
Shingle/ Tarpaper
Roof 840 sq.
ft.
Miscellaneous
Good (No Damage)
Category I Nonfriable
Potential for
Significant Damage
Gray and
Maroon Sheet Floor
Kitchen 120 sq.
ft.
Miscellaneous
Good (No Damage)
Category I Nonfriable
Potential for
Significant Damage
Beige Square Pattern Sheet Floor/Mastic
Kitchen 120 sq.
ft.
Miscellaneous
Good (No Damage)
Category I Nonfriable
Potential for
Significant Damage
Beige Tan
Sheet Floor
Bathroom and HVAC
Closet 75 sq. ft. Miscellaneous
Good (No Damage)
Category I Nonfriable
Potential for
Significant Damage
Texture Ceiling
Ceilings Throughout
840 sq.
ft.
Surfacing Material
Good (No Damage)
Friable
(RACM)
Potential for
Significant Damage
Drywall/Joint
Compound
Ceilings Throughout and Select
Walls
2000 sq.
ft.
Surfacing Material
Good (No Damage)
Friable
(RACM)
Potential for
Significant Damage
007 Caulking Exterior
Windows 200 ln.
ft.
Miscellaneous
Good (No Damage)
Category
II
Nonfriable
Potential for
Significant Damage
Sample Results
Sample # Material % Mineral Type Regulatory Result Analysis Type
001A Gray, White, Green, Red Shingle ND ND Tested Negative by Lab PLM
Black Tarpaper ND ND Tested Negative by Lab PLM
001B Gray, White, Green, Red Shingle ND ND Tested Negative by Lab PLM
Black Tarpaper ND ND Tested Negative by Lab PLM
001C Gray, White, Green, Red Shingle ND ND Tested Negative by Lab TEM
Black Tarpaper ND ND Tested Negative by Lab TEM 002A Gray, Off-white, Maroon Sheet Floor ND ND Tested Negative by Lab PLM 002B Gray, Off-white, Maroon Sheet Floor ND ND Tested Negative by Lab PLM 002C Gray, Off-white, Maroon Sheet Floor ND ND Tested Negative by Lab TEM
003A Beige Sheet Floor ND ND Tested Negative by Lab PLM
Brown Mastic ND ND Tested Negative by Lab PLM
003B Beige Sheet Floor ND ND Tested Negative by Lab PLM Off-white Mastic ND ND Tested Negative by Lab PLM
003C Beige Sheet Floor ND ND Tested Negative by Lab TEM
Brown Mastic ND ND Tested Negative by Lab TEM Off-white Mastic ND ND Tested Negative by Lab TEM
004A Beige, Tan Sheet Floor ND ND Tested Negative by Lab PLM 004B Beige, Tan Sheet Floor ND ND Tested Negative by Lab PLM 004C Beige, Tan Sheet Floor ND ND Tested Negative by Lab TEM 005A Gray, White Texture Ceiling ND ND Tested Negative by Lab PLM 005B Gray, White Texture Ceiling ND ND Tested Negative by Lab PLM 005C Gray, White Texture Ceiling ND ND Tested Negative by Lab PLM 005D Gray, White Texture Ceiling ND ND Tested Negative by Lab PLM 005E Gray, White Texture Ceiling ND ND Tested Negative by Lab PLM
006A White Joint Compound ND ND Tested Negative by Lab PLM
White Drywall ND ND Tested Negative by Lab PLM
006B White Joint Compound ND ND Tested Negative by Lab PLM
White Drywall ND ND Tested Negative by Lab PLM
006C White Joint Compound ND ND Tested Negative by Lab PLM
White Drywall ND ND Tested Negative by Lab PLM
006D White Joint Compound ND ND Tested Negative by Lab PLM
White Drywall ND ND Tested Negative by Lab PLM
006E White Joint Compound ND ND Tested Negative by Lab PLM
White Drywall ND ND Tested Negative by Lab PLM 007A White, Clear Caulking ND ND Tested Negative by Lab PLM 007B White, Clear Caulking ND ND Tested Negative by Lab PLM 007C White, Clear Caulking ND ND Tested Negative by Lab TEM
Please understand that quantities are estimated and should not be used for bidding purposes. Field conditions should be verified prior to bidding.
Site location plan and sample location plan is identified as Figures 1 and 2 in Appendix 1 of this report, photographs are in Appendix 2, laboratory results are in Appendix 3, and license is in Appendix 4.
5.0 CONCLUSIONS
The EPA and SCDHEC define materials as asbestos containing if an asbestos content >1% is detected in a representative sample. No asbestos >1 % was detected in the suspect materials sampled and analyzed for the structure located at 279 Freemont Road in Longs, South Carolina:
Material ID Material Regulatory Result Highest Analytical Result Est. Quantity There are no homogenous materials for this project that have tested positive containing asbestos
A copy of this report along with a demolition application should be submitted to SCDHEC at least 10 working days prior to any demolition activities. Additionally, a copy of this report should be provided to the contractors to assist with compliance with applicable State and Federal regulations.
The possibility exists that suspect materials were undetected in inaccessible areas such as areas deemed unsafe to enter, behind exterior veneer, pipe chases, or wall voids. If additional suspect materials not included in this report are discovered during renovations, bulk samples should be collected and analyzed for asbestos content.
APPENDIX 1
Site Location Plan and Sample Location Plan
Site Location Plan 279 Freemont Rd Longs, SC Project # - 2023-01-106
Scale: Not to Scale Reviewed By: DS Date: 4/4/23 Source: N/A
Figure 1
Subject Property
Asbestos Sample Location Plan 279 Freemont Rd Longs, SC Project # - 2023-01-106
Figure 2 Scale: Not to Scale Reviewed By: DS Date: 4/4/23 Source: N/A
Figure 2
LEGEND
Sample Location
Asbestos Containing Sample Location
002A-C
Kitchen Living Room
Bedroom
Bath
Bath Master
Bedroom
Closet
003A-C
004A-C
006C
005E
005A 006A
005B 006B
005C
005D 006D-E
001A 007A-C 001C001B
APPENDIX 2
Photographs
Site Photos
Interior Bedroom
Interior Living Room
Interior, Kitchen
Interior, Bathroom
Interior, Bathroom
Interior, Bedroom
Interior, Kitchen
Interior HVAC Closet
Interior, Living Room
Exterior
APPENDIX 3
Laboratory Results
April 14, 2023
Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
CLIENT PROJECT: 279 Freemont Rd
CEI LAB CODE: B237428
Dear Customer:
Enclosed are asbestos analysis results for PLM Bulk samples received at our laboratory on April 4, 2023. The samples were analyzed for asbestos using polarizing light microscopy (PLM) per the EPA 600 Method.
Sample results containing >1% asbestos are considered asbestos-containing materials (ACMs) per EPA regulatory requirements. The detection limit for the EPA 600 Method is <1% asbestos by weight as determined by visual estimation.
Thank you for your business and we look forward to continuing good relations.
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Tianbao Bai, Ph.D., CIH Laboratory Director
Kind Regards, ASBESTOS ANALYTICAL REPORT
By: Polarized Light Microscopy
Prepared for
Asbestos Inspections LLC
CLIENT PROJECT:
LAB CODE:
TEST METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
REPORT DATE:
TOTAL SAMPLES ANALYZED:
# SAMPLES >1% ASBESTOS:
279 Freemont Rd
04/14/23
B237428
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Asbestos Report Summary By: POLARIZING LIGHT MICROSCOPY
PROJECT: 279 Freemont Rd LAB CODE: B237428
Client ID Lab ID Color Sample Description
ASBESTOS
%Layer
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
001A Layer 1 B237428.01 Gray White, Green Red
Shingle None Detected001A
Layer 2 B237428.01 Black Tarpaper None Detected
001B Layer 1 B237428.02 Gray White, Green Red
Shingle None Detected001B
Layer 2 B237428.02 Black Tarpaper None Detected
001C Layer 1 B237428.03 Sample Submitted for TEM Analysis
001C
Layer 2 B237428.03 Sample Submitted for TEM Analysis
002A B237428.04 Gray,Off-white Maroon
Sheet Floor None Detected002A
002B B237428.05 Gray,Off-white Maroon
Sheet Floor None Detected002B
002C B237428.06 Sample Submitted for TEM Analysis
002C
003A B237428.07A Beige Sheet Floor None Detected003A
B237428.07B Brown Mastic None Detected
003B B237428.08A Beige Sheet Floor None Detected003B
B237428.08B Off-white Mastic None Detected
003C B237428.09A Sample Submitted for TEM Analysis
003C
B237428.09B Sample Submitted for TEM Analysis
004A B237428.10 Beige,Tan Sheet Floor None Detected004A
004B B237428.11 Beige,Tan Sheet Floor None Detected004B
004C B237428.12 Sample Submitted for TEM Analysis
004C
005A B237428.13 Gray,White Texture Ceiling None Detected005A
005B B237428.14 Gray,White Texture Ceiling None Detected005B
005C B237428.15 Gray,White Texture Ceiling None Detected005C
005D B237428.16 Gray,White Texture Ceiling None Detected005D
005E B237428.17 Gray,White Texture Ceiling None Detected005E
006A Layer 1 B237428.18 White Joint Compound None Detected006A
Page 1 of 2730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Asbestos Report Summary
PROJECT: 279 Freemont Rd LAB CODE: B237428
Client ID Lab ID Color Sample Description
ASBESTOS
%Layer
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
Layer 2 B237428.18 White Drywall None Detected
006B Layer 1 B237428.19 White Joint Compound None Detected006B
Layer 2 B237428.19 White Drywall None Detected
006C Layer 1 B237428.20 White Joint Compound None Detected006C
Layer 2 B237428.20 White Drywall None Detected
006D Layer 1 B237428.21 White Joint Compound None Detected006D
Layer 2 B237428.21 White Drywall None Detected
006E Layer 1 B237428.22 White Joint Compound None Detected006E
Layer 2 B237428.22 White Drywall None Detected
007A B237428.23 White,Clear Caulking None Detected007A
007B B237428.24 White,Clear Caulking None Detected007B
007C B237428.25 Sample Submitted for TEM Analysis
007C
Page 2 of 2730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
ASBESTOS BULK ANALYSIS
Lab Code: B237428 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 279 Freemont Rd
Fibrous
Gray White, Green Red
001A
B237428.01
30%Heterogeneous
Fibrous Bound
60% 10%
Fiberglass Tar Gravel
None Detected Layer 1
Shingle
Black Tarpaper
B237428.01 70%Homogeneous
Fibrous Bound
30%Cellulose Tar None DetectedLayer 2
Gray White, Green Red
001B
B237428.02
30%Heterogeneous
Fibrous Bound
60% 10%
Fiberglass Tar Gravel
None Detected Layer 1
Shingle
Black Tarpaper
B237428.02 70%Homogeneous
Fibrous Bound
30%Cellulose Tar None DetectedLayer 2
001C
B237428.03 Layer 1
Sample Submitted for TEM Analysis
Sample Submitted for TEM AnalysisB237428.03
Layer 2
Gray,Off-white Maroon
Sheet Floor002A B237428.04
30%Heterogeneous
Fibrous Bound
50% 20%
Cellulose Vinyl Binder
None Detected
Page 1 of 6730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Lab Code: B237428 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 279 Freemont Rd
Fibrous
Gray,Off-white Maroon
Sheet Floor002B B237428.05
30%Heterogeneous
Fibrous Bound
50% 20%
Cellulose Vinyl Binder
None Detected
Sample Submitted for TEM Analysis
002C B237428.06
Beige Sheet Floor003A
B237428.07A 30% 10%
Heterogeneous
Fibrous Bound
50% 10%
Cellulose Fiberglass
Vinyl Binder
None Detected
Brown MasticB237428.07B 2%Homogeneous
Non-fibrous Bound
98%Cellulose Mastic None Detected
Beige Sheet Floor003B
B237428.08A 30% 10%
Heterogeneous
Fibrous Bound
50% 10%
Cellulose Fiberglass
Vinyl Binder
None Detected
Off-white MasticB237428.08B 2%Homogeneous
Non-fibrous Bound
98%Cellulose Mastic None Detected
Sample Submitted for TEM Analysis
003C B237428.09A
Sample Submitted for TEM Analysis
B237428.09B
Page 2 of 6730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Lab Code: B237428 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 279 Freemont Rd
Fibrous
Beige,Tan Sheet Floor004A
B237428.10 Homogeneous
Non-fibrous Bound
100% Vinyl None Detected
Beige,Tan Sheet Floor004B
B237428.11 Homogeneous
Non-fibrous Bound
100% Vinyl None Detected
Sample Submitted for TEM Analysis
004C B237428.12
Gray,White Texture Ceiling005A
B237428.13 Heterogeneous
Non-fibrous Bound
50% 20% 30%
Binder Calc Carb Foam
None Detected
Gray,White Texture Ceiling005B
B237428.14 Heterogeneous
Non-fibrous Bound
50% 20% 30%
Binder Calc Carb Foam
None Detected
Gray,White Texture Ceiling005C
B237428.15 Heterogeneous
Non-fibrous Bound
50% 20% 30%
Binder Calc Carb Foam
None Detected
Gray,White Texture Ceiling005D
B237428.16 Heterogeneous
Non-fibrous Bound
50% 20% 30%
Binder Calc Carb Foam
None Detected
Gray,White Texture Ceiling005E
B237428.17 Heterogeneous
Non-fibrous Bound
50% 20% 30%
Binder Calc Carb Foam
None Detected
Page 3 of 6730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Lab Code: B237428 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 279 Freemont Rd
Fibrous
White 006A
B237428.18
Heterogeneous
Non-fibrous Bound
60% 35% 5%
Binder Calc Carb Paint
None Detected Layer 1
Joint Compound
White Drywall
B237428.18 15%Heterogeneous
Fibrous Bound
85%Cellulose Gypsum None DetectedLayer 2
White 006B
B237428.19
Heterogeneous
Non-fibrous Bound
60% 35% 5%
Binder Calc Carb Paint
None Detected Layer 1
Joint Compound
White Drywall
B237428.19 15%Heterogeneous
Fibrous Bound
85%Cellulose Gypsum None DetectedLayer 2
White 006C
B237428.20
Heterogeneous
Non-fibrous Bound
60% 35% 5%
Binder Calc Carb Paint
None Detected Layer 1
Joint Compound
White Drywall
B237428.20 15%Heterogeneous
Fibrous Bound
85%Cellulose Gypsum None DetectedLayer 2
White 006D
B237428.21
Heterogeneous
Non-fibrous Bound
60% 35% 5%
Binder Calc Carb Paint
None Detected Layer 1
Joint Compound
Page 4 of 6730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Lab Code: B237428 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 279 Freemont Rd
Fibrous
White Drywall
B237428.21 15%Heterogeneous
Fibrous Bound
85%Cellulose Gypsum None DetectedLayer 2
White 006E
B237428.22
Heterogeneous
Non-fibrous Bound
60% 35% 5%
Binder Calc Carb Paint
None Detected Layer 1
Joint Compound
White Drywall
B237428.22 15%Heterogeneous
Fibrous Bound
85%Cellulose Gypsum None DetectedLayer 2
White,Clear Caulking007A
B237428.23 Heterogeneous
Non-fibrous Bound
98% 2%
Caulk Paint
None Detected
White,Clear Caulking007B
B237428.24 Heterogeneous
Non-fibrous Bound
98% 2%
Caulk Paint
None Detected
Sample Submitted for TEM Analysis
007C B237428.25
Page 5 of 6730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
LEGEND: Non-Anth = Non-Asbestiform Anthophyllite Non-Trem = Non-Asbestiform Tremolite Calc Carb = Calcium Carbonate
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
REPORTING LIMIT: <1% by visual estimation
REPORTING LIMIT FOR POINT COUNTS: 0.25% by 400 Points or 0.1% by 1,000 Points
REGULATORY LIMIT: >1% by weight
Due to the limitations of the EPA 600 method, nonfriable organically bound materials (NOBs) such as vinyl floor tiles can be difficult to analyze via polarized light microscopy (PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request.
This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results.
Interpretation of the analytical results is the sole responsibility of the client. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.
Information provided by customer includes customer sample ID and sample description.
ANALYST: APPROVED BY:
Tianbao Bai, Ph.D., CIH Laboratory Director
Ryan Steele
April 18, 2023
Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
CLIENT PROJECT: 279 Freemont Rd
LAB CODE: T230880
Dear Customer:
Enclosed are asbestos analysis results for TEM bulk samples received at our laboratory on April 11, 2023. The samples were analyzed for asbestos using transmission electron microscopy (TEM) per Chatfield/EPA 600/R-93/116 Sec. 2.5.5.1 method.
Sample results containing > 1% asbestos are considered asbestos-containing materials (ACMs) per the EPA regulatory requirements. The detection limit for the TEM Chatfield/EPA 600/R-93/116 Sec. 2.5.5.1 method is <1% depending on the processed weight and constituents of the sample.
Thank you for your business and we look forward to continuing good relations.
Tianbao Bai, Ph.D., CIH Laboratory Director
Kind Regards, ASBESTOS ANALYTICAL REPORT
By: Transmission Electron Microscopy
Prepared for
Asbestos Inspections LLC
CLIENT PROJECT:
LAB CODE:
TEST METHOD: Bulk Chatfield EPA 600 / R93 / 116 Sec. 2.5.5.1
REPORT DATE:
279 Freemont Rd
04/18/23
T230880
By: TRANSMISSION ELECTRON MICROSCOPY
Lab Code: T230880 Date Received: 04-11-23 Date Analyzed: 04-17-23 Date Reported: 04-18-23
Client ID Lab ID
Material Description
TEM BULK CHATFIELD / EPA 600 / R93 / 116 Sec. 2.5.5.1
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 279 Freemont Rd
Sample Weight
(g)
Organic Material
Acid Soluble Material
Acid Insoluble Material
Asbestos
T57930 001C Shingle 0.431 20 44.5 35.5 None
Detected
T57931 001C Tarpaper 0.385 93.2 .8 6 None
Detected
T57932 002C Sheet Floor 0.249 53 45.4 1.6 None
Detected
T57933 003C Sheet Floor 0.287 53 23 24 None
Detected
T57934 003C Brown Mastic 0.069 27.5 13 59.5 None
Detected
T57935 003C Off-White Mastic 0.058 20.7 3.4 75.9 None
Detected
T57936 004C Sheet Floor 0.206 96.6 2.4 1 None
Detected
T57937 007C Caulking 0.249 31.3 49.8 18.9 None
Detected
LEGEND: None
METHOD: CHATFIELD & EPA/600/R-93/116 Sec. 2.5.5.1
LIMIT OF DETECTION: Varies with the weight and constituents of the sample (<1%)
REGULATORY LIMIT: >1% by weight
This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI (ECEI). ECEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results.
Interpretation of the analytical results is the sole responsibility of the client. Estimated measurement of uncertainty is available on request and in compliance with regulatory requirements. Samples were received in acceptable condition unless otherwise noted.
Information provided by customer includes customer sample ID, location, volume and area as well as date and time of sampling.
ECEI recommends between 0.20 and 0.50 grams of sample material for TEM bulk analysis.
Any weight below 0.10 grams is considered below protocol guidelines.
**Indicates sample weight below 0.05 grams and is considered insufficient for quantitative analysis.
ANALYST: APPROVED BY:
Tianbao Bai, Ph.D., CIH Laboratory Director
Stacy Ulrich
APPENDIX 4
License
12884, 06/30/2023, North Carolina, Dawn
Schoolcraft
1909008, 09/30/2023, South Carolina, Dawn
LBP-R-I162035-2, 03/16/2024, South Carolina, BI-00738, 06/06/2023, South Carolina, Dawn
File details come from the government source that posted it. Updated .