This document is an Asbestos Inspection Report prepared by Asbestos Inspections, LLC for Horry County Government, specifically for a mobile home located at 279 Freemont Road in Longs, South Carolina. The inspection was conducted on April 3, 2023, by Dawn Schoolcraft, a certified asbestos building inspector, in preparation for the property's scheduled demolition. The report follows procedures specified in SCDHEC regulation 61.86.1 and OSHA regulation 29 CFR 1926, with representative bulk samples analyzed by a National Voluntary Laboratory Accreditation Program (NVLAP) certified laboratory.

The comprehensive inspection covered an approximately 840 square-foot mobile home with metal siding and a shingled roof, examining various materials including shingles, tarpaper, sheet flooring, mastic, textured ceiling, drywall, and joint compound. Critically, the laboratory analysis using both Polarized Light Microscopy (PLM) and Transmission Electron Microscopy (TEM) methods found no asbestos-containing materials (ACMs) exceeding the 1% regulatory threshold. The report recommends submitting a copy of the inspection report along with a demolition application to SCDHEC at least 10 working days prior to demolition activities, and providing the report to contractors to ensure compliance with state and federal regulations.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASBESTOS INSPECTION REPORT

279 Freemont Road

Longs, South Carolina Asbestos Inspections, LLC Project # 2023-01-106

Performed in general accordance with SCDHEC regulation 61-86.1 along with OSHA regulation 29 CFR 1926

Assessment Completed by:

Asbestos Inspections, LLC 4686 Pee Dee Highway

Conway, South Carolina 29527

(843) 995-5197

Dawn Schoolcraft

SCDHEC ID# BI-00738

Assessment Completed For:

Mr. Sam LoFaso with Horry County Government 1515 Fourth Avenue

Conway, South Carolina 29526

Inspection Completed On – April 3, 2023 Report Prepared On – April 20, 2023

Asbestos Inspection Report

Project Number – 2023-01-106 April 20, 2023

TABLE OF CONTENTS

1.0 SIGNATURE PAGE

2.0 COVER LETTER

3.0 EXECUTIVE SUMMARY

1.1 Scope and Purpose

2.1 Facility Conditions

3.1 Findings and Conclusions

4.0 ASBESTOS ASSESSMENT DATA

5.0 CONCLUSIONS

Appendix 1- Site Location Plan and Sample Location Plan Appendix 2- Photographs Appendix 3- Laboratory Results Appendix 4- License

1.0 SIGNATURE PAGE

This report has been performed at the request of Mr. Sam LoFaso with Horry County Government. The inspection was conducted by Mrs. Dawn Schoolcraft with Asbestos Inspections, LLC on April 03, 2023.

The report was prepared and reviewed by the undersigned inspector.

Inspection Performed by: SCDEHC# Signature Date

Dawn Schoolcraft BI-00738 Dawn Schoolcraft April 03, 2023

Report Prepared by:

Dawn Schoolcraft BI-00738 Dawn Schoolcraft April 20, 2023

Report Reviewed by:

Dawn Schoolcraft BI-00738 Dawn Schoolcraft April 20, 2023

2.0 COVER LETTER

Mr. Sam LoFaso with Horry County Government 1515 Fourth Avenue Conway, South Carolina 29526

Subject:

Asbestos Inspection Report 279 Freemont Road Longs, South Carolina 29568 Asbestos Inspections, LLC Project # 2023-01-106

Asbestos Inspections, LLC has completed an Asbestos Assessment and Inspection for the structure located at 279 Freemont Road, in Longs, South Carolina. The inspection was completed on April 03, 2023 by a South Carolina Department of Health and Environmental Control (SCDHEC) building inspector.

The following report summarizes the project background, assessment procedures, results, and conclusions. The results presented in this report are indicative of conditions during the time of the inspection and of the specific areas outlined. The information provided in this report should not be used as a bidding document and field conditions should be verified. Should suspect building materials, not included within this report, be identified or impacted during the destructive activities, bulk samples must be collected and analyzed for asbestos content.

I appreciate this opportunity to provide my services. Should you have any questions concerning this report, please contact me at (843) 995-5197.

Sincerely, Asbestos Building Inspector (SCDHEC #BI-00738)

3.0 EXECUTIVE SUMMARY

1.1 Scope and Purpose

Mr. Sam LoFaso with Horry County Government requested this assessment for the structure located at 279 Freemont Road in Longs, South Carolina. Based on information obtained from you, the structure is scheduled for demolition. The purpose of this assessment was to identify asbestos containing materials (ACMs) prior to demolition.

The inspection was completed in accordance with procedures specified in SCDHEC regulation 61.86.1 along with Occupational Safety and Health Administration (OSHA) regulation 29 Code of the Federal Regulations (CFR) 1926. The representative bulk samples collected were analyzed by a National Voluntary Laboratory Accreditation Program (NVLAP) certified laboratory which is administered by the National Institute of Standards and Technology (NIST). This report has been prepared in accordance with Environmental Protection Agency (EPA) 40 CFR, 763.85(a)(4).

2.1 Facility Conditions

The subject structure is an approximately 840 square-feet, mobile home with metal siding, and a shingled roof. The interior consists of both wood panelled and drywall walls, drywall ceilings, carpet, and sheet flooring. Some flooring and finishes have been removed prior to inspection. Suspect building materials sampled during this inspection include shingles, tarpaper, sheet floor, mastic, textured ceiling, drywall, and joint compound.

The possibility exists that suspect materials were undetected in inaccessible areas such as areas deemed unsafe to enter, underneath or behind contents of units, behind exterior veneer, pipe chases, or wall voids. If additional suspect materials not included in this report are discovered during demolition, bulk samples should be collected and analyzed for asbestos content.

3.1 Findings and Conclusions

The EPA and SCDHEC define materials as asbestos containing if an asbestos content >1% is identified in a representative sample. No asbestos >1% was detected in the suspect materials collected and analyzed:

Material ID Material Regulatory Result Highest Analytical Result Est. Quantity There are no homogenous materials for this project that have tested positive containing asbestos

A copy of this report along with a demolition application should be submitted to SCDHEC at least 10 working days prior to any demolition activities. Additionally, a copy of this report should be provided to the contractors to assist with compliance with applicable State and Federal regulations.

The results presented in this report are indicative of conditions during the time of the assessment. The information provided in this report should not be used as a bidding document and field conditions and quantities should be verified.

4.0 ASBESTOS ASSESSMENT DATA

The assessment was performed by observing and sampling suspect ACMs in the unit prior to the scheduled renovations. Representative bulk samples were then extracted, recorded on a chain of custody, and submitted to Eurofins/CEI Labs of Cary, North Carolina for laboratory analysis. The samples were tested via Polarized Light Microscopy (PLM); however, SCDHEC requires a Transmission Electron Microscopy (TEM) test be performed for all non-friable organically bound material found negative via PLM.

The following tables exhibits the suspect material sampled, location, quantity of material sampled, condition of material, potential for future disturbance, and laboratory analysis.

All Materials Sampled

Material Id

Material Space Name

Quantity Material Category

Current Condition

Friability Damage Potential

Physical Assessment Category

Shingle/ Tarpaper

Roof 840 sq.

ft.

Miscellaneous

Good (No Damage)

Category I Nonfriable

Potential for

Significant Damage

Gray and

Maroon Sheet Floor

Kitchen 120 sq.

ft.

Miscellaneous

Good (No Damage)

Category I Nonfriable

Potential for

Significant Damage

Beige Square Pattern Sheet Floor/Mastic

Kitchen 120 sq.

ft.

Miscellaneous

Good (No Damage)

Category I Nonfriable

Potential for

Significant Damage

Beige Tan

Sheet Floor

Bathroom and HVAC

Closet 75 sq. ft. Miscellaneous

Good (No Damage)

Category I Nonfriable

Potential for

Significant Damage

Texture Ceiling

Ceilings Throughout

840 sq.

ft.

Surfacing Material

Good (No Damage)

Friable

(RACM)

Potential for

Significant Damage

Drywall/Joint

Compound

Ceilings Throughout and Select

Walls

2000 sq.

ft.

Surfacing Material

Good (No Damage)

Friable

(RACM)

Potential for

Significant Damage

007 Caulking Exterior

Windows 200 ln.

ft.

Miscellaneous

Good (No Damage)

Category

II

Nonfriable

Potential for

Significant Damage

Sample Results

Sample # Material % Mineral Type Regulatory Result Analysis Type

001A Gray, White, Green, Red Shingle ND ND Tested Negative by Lab PLM

Black Tarpaper ND ND Tested Negative by Lab PLM

001B Gray, White, Green, Red Shingle ND ND Tested Negative by Lab PLM

Black Tarpaper ND ND Tested Negative by Lab PLM

001C Gray, White, Green, Red Shingle ND ND Tested Negative by Lab TEM

Black Tarpaper ND ND Tested Negative by Lab TEM 002A Gray, Off-white, Maroon Sheet Floor ND ND Tested Negative by Lab PLM 002B Gray, Off-white, Maroon Sheet Floor ND ND Tested Negative by Lab PLM 002C Gray, Off-white, Maroon Sheet Floor ND ND Tested Negative by Lab TEM

003A Beige Sheet Floor ND ND Tested Negative by Lab PLM

Brown Mastic ND ND Tested Negative by Lab PLM

003B Beige Sheet Floor ND ND Tested Negative by Lab PLM Off-white Mastic ND ND Tested Negative by Lab PLM

003C Beige Sheet Floor ND ND Tested Negative by Lab TEM

Brown Mastic ND ND Tested Negative by Lab TEM Off-white Mastic ND ND Tested Negative by Lab TEM

004A Beige, Tan Sheet Floor ND ND Tested Negative by Lab PLM 004B Beige, Tan Sheet Floor ND ND Tested Negative by Lab PLM 004C Beige, Tan Sheet Floor ND ND Tested Negative by Lab TEM 005A Gray, White Texture Ceiling ND ND Tested Negative by Lab PLM 005B Gray, White Texture Ceiling ND ND Tested Negative by Lab PLM 005C Gray, White Texture Ceiling ND ND Tested Negative by Lab PLM 005D Gray, White Texture Ceiling ND ND Tested Negative by Lab PLM 005E Gray, White Texture Ceiling ND ND Tested Negative by Lab PLM

006A White Joint Compound ND ND Tested Negative by Lab PLM

White Drywall ND ND Tested Negative by Lab PLM

006B White Joint Compound ND ND Tested Negative by Lab PLM

White Drywall ND ND Tested Negative by Lab PLM

006C White Joint Compound ND ND Tested Negative by Lab PLM

White Drywall ND ND Tested Negative by Lab PLM

006D White Joint Compound ND ND Tested Negative by Lab PLM

White Drywall ND ND Tested Negative by Lab PLM

006E White Joint Compound ND ND Tested Negative by Lab PLM

White Drywall ND ND Tested Negative by Lab PLM 007A White, Clear Caulking ND ND Tested Negative by Lab PLM 007B White, Clear Caulking ND ND Tested Negative by Lab PLM 007C White, Clear Caulking ND ND Tested Negative by Lab TEM

Please understand that quantities are estimated and should not be used for bidding purposes. Field conditions should be verified prior to bidding.

Site location plan and sample location plan is identified as Figures 1 and 2 in Appendix 1 of this report, photographs are in Appendix 2, laboratory results are in Appendix 3, and license is in Appendix 4.

5.0 CONCLUSIONS

The EPA and SCDHEC define materials as asbestos containing if an asbestos content >1% is detected in a representative sample. No asbestos >1 % was detected in the suspect materials sampled and analyzed for the structure located at 279 Freemont Road in Longs, South Carolina:

Material ID Material Regulatory Result Highest Analytical Result Est. Quantity There are no homogenous materials for this project that have tested positive containing asbestos

A copy of this report along with a demolition application should be submitted to SCDHEC at least 10 working days prior to any demolition activities. Additionally, a copy of this report should be provided to the contractors to assist with compliance with applicable State and Federal regulations.

The possibility exists that suspect materials were undetected in inaccessible areas such as areas deemed unsafe to enter, behind exterior veneer, pipe chases, or wall voids. If additional suspect materials not included in this report are discovered during renovations, bulk samples should be collected and analyzed for asbestos content.

APPENDIX 1

Site Location Plan and Sample Location Plan

Site Location Plan 279 Freemont Rd Longs, SC Project # - 2023-01-106

Scale: Not to Scale Reviewed By: DS Date: 4/4/23 Source: N/A

Figure 1

Subject Property

Asbestos Sample Location Plan 279 Freemont Rd Longs, SC Project # - 2023-01-106

Figure 2 Scale: Not to Scale Reviewed By: DS Date: 4/4/23 Source: N/A

Figure 2

LEGEND

Sample Location

Asbestos Containing Sample Location

002A-C

Kitchen Living Room

Bedroom

Bath

Bath Master

Bedroom

Closet

003A-C

004A-C

006C

005E

005A 006A

005B 006B

005C

005D 006D-E

001A 007A-C 001C001B

APPENDIX 2

Photographs

Site Photos

Interior Bedroom

Interior Living Room

Interior, Kitchen

Interior, Bathroom

Interior, Bathroom

Interior, Bedroom

Interior, Kitchen

Interior HVAC Closet

Interior, Living Room

Exterior

APPENDIX 3

Laboratory Results

April 14, 2023

Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527

CLIENT PROJECT: 279 Freemont Rd

CEI LAB CODE: B237428

Dear Customer:

Enclosed are asbestos analysis results for PLM Bulk samples received at our laboratory on April 4, 2023. The samples were analyzed for asbestos using polarizing light microscopy (PLM) per the EPA 600 Method.

Sample results containing >1% asbestos are considered asbestos-containing materials (ACMs) per EPA regulatory requirements. The detection limit for the EPA 600 Method is <1% asbestos by weight as determined by visual estimation.

Thank you for your business and we look forward to continuing good relations.

730 SE Maynard Road • Cary, NC 27511 • 919.481.1413

Tianbao Bai, Ph.D., CIH Laboratory Director

Kind Regards, ASBESTOS ANALYTICAL REPORT

By: Polarized Light Microscopy

Prepared for

Asbestos Inspections LLC

CLIENT PROJECT:

LAB CODE:

TEST METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

REPORT DATE:

TOTAL SAMPLES ANALYZED:

# SAMPLES >1% ASBESTOS:

279 Freemont Rd

04/14/23

B237428

730 SE Maynard Road • Cary, NC 27511 • 919.481.1413

Asbestos Report Summary By: POLARIZING LIGHT MICROSCOPY

PROJECT: 279 Freemont Rd LAB CODE: B237428

Client ID Lab ID Color Sample Description

ASBESTOS

%Layer

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

001A Layer 1 B237428.01 Gray White, Green Red

Shingle None Detected001A

Layer 2 B237428.01 Black Tarpaper None Detected

001B Layer 1 B237428.02 Gray White, Green Red

Shingle None Detected001B

Layer 2 B237428.02 Black Tarpaper None Detected

001C Layer 1 B237428.03 Sample Submitted for TEM Analysis

001C

Layer 2 B237428.03 Sample Submitted for TEM Analysis

002A B237428.04 Gray,Off-white Maroon

Sheet Floor None Detected002A

002B B237428.05 Gray,Off-white Maroon

Sheet Floor None Detected002B

002C B237428.06 Sample Submitted for TEM Analysis

002C

003A B237428.07A Beige Sheet Floor None Detected003A

B237428.07B Brown Mastic None Detected

003B B237428.08A Beige Sheet Floor None Detected003B

B237428.08B Off-white Mastic None Detected

003C B237428.09A Sample Submitted for TEM Analysis

003C

B237428.09B Sample Submitted for TEM Analysis

004A B237428.10 Beige,Tan Sheet Floor None Detected004A

004B B237428.11 Beige,Tan Sheet Floor None Detected004B

004C B237428.12 Sample Submitted for TEM Analysis

004C

005A B237428.13 Gray,White Texture Ceiling None Detected005A

005B B237428.14 Gray,White Texture Ceiling None Detected005B

005C B237428.15 Gray,White Texture Ceiling None Detected005C

005D B237428.16 Gray,White Texture Ceiling None Detected005D

005E B237428.17 Gray,White Texture Ceiling None Detected005E

006A Layer 1 B237428.18 White Joint Compound None Detected006A

Page 1 of 2730 SE Maynard Road • Cary, NC 27511 • 919.481.1413

Asbestos Report Summary

PROJECT: 279 Freemont Rd LAB CODE: B237428

Client ID Lab ID Color Sample Description

ASBESTOS

%Layer

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

Layer 2 B237428.18 White Drywall None Detected

006B Layer 1 B237428.19 White Joint Compound None Detected006B

Layer 2 B237428.19 White Drywall None Detected

006C Layer 1 B237428.20 White Joint Compound None Detected006C

Layer 2 B237428.20 White Drywall None Detected

006D Layer 1 B237428.21 White Joint Compound None Detected006D

Layer 2 B237428.21 White Drywall None Detected

006E Layer 1 B237428.22 White Joint Compound None Detected006E

Layer 2 B237428.22 White Drywall None Detected

007A B237428.23 White,Clear Caulking None Detected007A

007B B237428.24 White,Clear Caulking None Detected007B

007C B237428.25 Sample Submitted for TEM Analysis

007C

Page 2 of 2730 SE Maynard Road • Cary, NC 27511 • 919.481.1413

ASBESTOS BULK ANALYSIS

Lab Code: B237428 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527

Project: 279 Freemont Rd

Fibrous

Gray White, Green Red

001A

B237428.01

30%Heterogeneous

Fibrous Bound

60% 10%

Fiberglass Tar Gravel

None Detected Layer 1

Shingle

Black Tarpaper

B237428.01 70%Homogeneous

Fibrous Bound

30%Cellulose Tar None DetectedLayer 2

Gray White, Green Red

001B

B237428.02

30%Heterogeneous

Fibrous Bound

60% 10%

Fiberglass Tar Gravel

None Detected Layer 1

Shingle

Black Tarpaper

B237428.02 70%Homogeneous

Fibrous Bound

30%Cellulose Tar None DetectedLayer 2

001C

B237428.03 Layer 1

Sample Submitted for TEM Analysis

Sample Submitted for TEM AnalysisB237428.03

Layer 2

Gray,Off-white Maroon

Sheet Floor002A B237428.04

30%Heterogeneous

Fibrous Bound

50% 20%

Cellulose Vinyl Binder

None Detected

Page 1 of 6730 SE Maynard Road • Cary, NC 27511 • 919.481.1413

Lab Code: B237428 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527

Project: 279 Freemont Rd

Fibrous

Gray,Off-white Maroon

Sheet Floor002B B237428.05

30%Heterogeneous

Fibrous Bound

50% 20%

Cellulose Vinyl Binder

None Detected

Sample Submitted for TEM Analysis

002C B237428.06

Beige Sheet Floor003A

B237428.07A 30% 10%

Heterogeneous

Fibrous Bound

50% 10%

Cellulose Fiberglass

Vinyl Binder

None Detected

Brown MasticB237428.07B 2%Homogeneous

Non-fibrous Bound

98%Cellulose Mastic None Detected

Beige Sheet Floor003B

B237428.08A 30% 10%

Heterogeneous

Fibrous Bound

50% 10%

Cellulose Fiberglass

Vinyl Binder

None Detected

Off-white MasticB237428.08B 2%Homogeneous

Non-fibrous Bound

98%Cellulose Mastic None Detected

Sample Submitted for TEM Analysis

003C B237428.09A

Sample Submitted for TEM Analysis

B237428.09B

Page 2 of 6730 SE Maynard Road • Cary, NC 27511 • 919.481.1413

Lab Code: B237428 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527

Project: 279 Freemont Rd

Fibrous

Beige,Tan Sheet Floor004A

B237428.10 Homogeneous

Non-fibrous Bound

100% Vinyl None Detected

Beige,Tan Sheet Floor004B

B237428.11 Homogeneous

Non-fibrous Bound

100% Vinyl None Detected

Sample Submitted for TEM Analysis

004C B237428.12

Gray,White Texture Ceiling005A

B237428.13 Heterogeneous

Non-fibrous Bound

50% 20% 30%

Binder Calc Carb Foam

None Detected

Gray,White Texture Ceiling005B

B237428.14 Heterogeneous

Non-fibrous Bound

50% 20% 30%

Binder Calc Carb Foam

None Detected

Gray,White Texture Ceiling005C

B237428.15 Heterogeneous

Non-fibrous Bound

50% 20% 30%

Binder Calc Carb Foam

None Detected

Gray,White Texture Ceiling005D

B237428.16 Heterogeneous

Non-fibrous Bound

50% 20% 30%

Binder Calc Carb Foam

None Detected

Gray,White Texture Ceiling005E

B237428.17 Heterogeneous

Non-fibrous Bound

50% 20% 30%

Binder Calc Carb Foam

None Detected

Page 3 of 6730 SE Maynard Road • Cary, NC 27511 • 919.481.1413

Lab Code: B237428 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527

Project: 279 Freemont Rd

Fibrous

White 006A

B237428.18

Heterogeneous

Non-fibrous Bound

60% 35% 5%

Binder Calc Carb Paint

None Detected Layer 1

Joint Compound

White Drywall

B237428.18 15%Heterogeneous

Fibrous Bound

85%Cellulose Gypsum None DetectedLayer 2

White 006B

B237428.19

Heterogeneous

Non-fibrous Bound

60% 35% 5%

Binder Calc Carb Paint

None Detected Layer 1

Joint Compound

White Drywall

B237428.19 15%Heterogeneous

Fibrous Bound

85%Cellulose Gypsum None DetectedLayer 2

White 006C

B237428.20

Heterogeneous

Non-fibrous Bound

60% 35% 5%

Binder Calc Carb Paint

None Detected Layer 1

Joint Compound

White Drywall

B237428.20 15%Heterogeneous

Fibrous Bound

85%Cellulose Gypsum None DetectedLayer 2

White 006D

B237428.21

Heterogeneous

Non-fibrous Bound

60% 35% 5%

Binder Calc Carb Paint

None Detected Layer 1

Joint Compound

Page 4 of 6730 SE Maynard Road • Cary, NC 27511 • 919.481.1413

Lab Code: B237428 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23

Client ID Lab ID

Lab Attributes

Lab Description

ASBESTOS

ASBESTOS BULK PLM, EPA 600 METHOD

NON-ASBESTOS COMPONENTS

Non-Fibrous

Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527

Project: 279 Freemont Rd

Fibrous

White Drywall

B237428.21 15%Heterogeneous

Fibrous Bound

85%Cellulose Gypsum None DetectedLayer 2

White 006E

B237428.22

Heterogeneous

Non-fibrous Bound

60% 35% 5%

Binder Calc Carb Paint

None Detected Layer 1

Joint Compound

White Drywall

B237428.22 15%Heterogeneous

Fibrous Bound

85%Cellulose Gypsum None DetectedLayer 2

White,Clear Caulking007A

B237428.23 Heterogeneous

Non-fibrous Bound

98% 2%

Caulk Paint

None Detected

White,Clear Caulking007B

B237428.24 Heterogeneous

Non-fibrous Bound

98% 2%

Caulk Paint

None Detected

Sample Submitted for TEM Analysis

007C B237428.25

Page 5 of 6730 SE Maynard Road • Cary, NC 27511 • 919.481.1413

LEGEND: Non-Anth = Non-Asbestiform Anthophyllite Non-Trem = Non-Asbestiform Tremolite Calc Carb = Calcium Carbonate

METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020

REPORTING LIMIT: <1% by visual estimation

REPORTING LIMIT FOR POINT COUNTS: 0.25% by 400 Points or 0.1% by 1,000 Points

REGULATORY LIMIT: >1% by weight

Due to the limitations of the EPA 600 method, nonfriable organically bound materials (NOBs) such as vinyl floor tiles can be difficult to analyze via polarized light microscopy (PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request.

This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results.

Interpretation of the analytical results is the sole responsibility of the client. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.

Information provided by customer includes customer sample ID and sample description.

ANALYST: APPROVED BY:

Tianbao Bai, Ph.D., CIH Laboratory Director

Ryan Steele

April 18, 2023

Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527

CLIENT PROJECT: 279 Freemont Rd

LAB CODE: T230880

Dear Customer:

Enclosed are asbestos analysis results for TEM bulk samples received at our laboratory on April 11, 2023. The samples were analyzed for asbestos using transmission electron microscopy (TEM) per Chatfield/EPA 600/R-93/116 Sec. 2.5.5.1 method.

Sample results containing > 1% asbestos are considered asbestos-containing materials (ACMs) per the EPA regulatory requirements. The detection limit for the TEM Chatfield/EPA 600/R-93/116 Sec. 2.5.5.1 method is <1% depending on the processed weight and constituents of the sample.

Thank you for your business and we look forward to continuing good relations.

Tianbao Bai, Ph.D., CIH Laboratory Director

Kind Regards, ASBESTOS ANALYTICAL REPORT

By: Transmission Electron Microscopy

Prepared for

Asbestos Inspections LLC

CLIENT PROJECT:

LAB CODE:

TEST METHOD: Bulk Chatfield EPA 600 / R93 / 116 Sec. 2.5.5.1

REPORT DATE:

279 Freemont Rd

04/18/23

T230880

By: TRANSMISSION ELECTRON MICROSCOPY

Lab Code: T230880 Date Received: 04-11-23 Date Analyzed: 04-17-23 Date Reported: 04-18-23

Client ID Lab ID

Material Description

TEM BULK CHATFIELD / EPA 600 / R93 / 116 Sec. 2.5.5.1

Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527

Project: 279 Freemont Rd

Sample Weight

(g)

Organic Material

Acid Soluble Material

Acid Insoluble Material

Asbestos

T57930 001C Shingle 0.431 20 44.5 35.5 None

Detected

T57931 001C Tarpaper 0.385 93.2 .8 6 None

Detected

T57932 002C Sheet Floor 0.249 53 45.4 1.6 None

Detected

T57933 003C Sheet Floor 0.287 53 23 24 None

Detected

T57934 003C Brown Mastic 0.069 27.5 13 59.5 None

Detected

T57935 003C Off-White Mastic 0.058 20.7 3.4 75.9 None

Detected

T57936 004C Sheet Floor 0.206 96.6 2.4 1 None

Detected

T57937 007C Caulking 0.249 31.3 49.8 18.9 None

Detected

LEGEND: None

METHOD: CHATFIELD & EPA/600/R-93/116 Sec. 2.5.5.1

LIMIT OF DETECTION: Varies with the weight and constituents of the sample (<1%)

REGULATORY LIMIT: >1% by weight

This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI (ECEI). ECEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results.

Interpretation of the analytical results is the sole responsibility of the client. Estimated measurement of uncertainty is available on request and in compliance with regulatory requirements. Samples were received in acceptable condition unless otherwise noted.

Information provided by customer includes customer sample ID, location, volume and area as well as date and time of sampling.

ECEI recommends between 0.20 and 0.50 grams of sample material for TEM bulk analysis.

Any weight below 0.10 grams is considered below protocol guidelines.

**Indicates sample weight below 0.05 grams and is considered insufficient for quantitative analysis.

ANALYST: APPROVED BY:

Tianbao Bai, Ph.D., CIH Laboratory Director

Stacy Ulrich

APPENDIX 4

License

12884, 06/30/2023, North Carolina, Dawn

Schoolcraft

1909008, 09/30/2023, South Carolina, Dawn

LBP-R-I162035-2, 03/16/2024, South Carolina, BI-00738, 06/06/2023, South Carolina, Dawn

File details come from the government source that posted it. Updated .