2023-24-006_Abatement 3832_3847 Woodridge Circle Asbestos Report.pdf
PDF 5 MB Posted
- Attached to
- Demolition of Condemned Dwellings (Group 6)
- Solicitation number
- 2023-24-006
- Issued by
- Florence County, South Carolina
About this file
This document is an Asbestos Inspection Report prepared by Asbestos Inspections, LLC for Horry County Government, specifically for a mobile home located at 3847 Woodridge Circle in Little River, South Carolina. The inspection was conducted on April 3, 2023, by Dawn Schoolcraft, a licensed asbestos building inspector, in preparation for the property's scheduled demolition. The report was performed in accordance with SCDHEC regulation 61.86.1 and OSHA regulation 29 CFR 1926, with representative bulk samples analyzed by a National Voluntary Laboratory Accreditation Program (NVLAP) certified laboratory.
The inspection covered an approximately 1,152 square-foot mobile home with vinyl siding, metal-framed windows, and a former asphalt shingled roof. Suspect materials sampled included drywall with joint compound, texture ceiling, sheet floor, tarpaper, and roofing materials. Laboratory analysis using Polarized Light Microscopy (PLM) and Transmission Electron Microscopy (TEM) methods found no asbestos-containing materials (ACMs) exceeding the 1% regulatory threshold. The report recommends submitting a copy of the inspection report along with a demolition application to SCDHEC at least 10 working days prior to any demolition activities, and advises contractors that additional suspect materials discovered during demolition should be sampled and analyzed for asbestos content.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ASBESTOS INSPECTION REPORT
3847 Woodridge Circle
Little River, South Carolina Asbestos Inspections, LLC Project # 2023-01-108
Performed in general accordance with SCDHEC regulation 61-86.1 along with OSHA regulation 29 CFR 1926
Assessment Completed by:
Asbestos Inspections, LLC 4686 Pee Dee Highway
Conway, South Carolina 29527
(843) 995-5197
Dawn Schoolcraft
SCDHEC ID# BI-00738
Assessment Completed For:
Mr. Sam LoFaso with Horry County Government 1515 Fourth Avenue
Conway, South Carolina 29526
Inspection Completed On – April 3, 2023 Report Prepared On – April 20, 2023
Asbestos Inspection Report
Project Number – 2023-01-108 April 20, 2023
TABLE OF CONTENTS
1.0 SIGNATURE PAGE
2.0 COVER LETTER
3.0 EXECUTIVE SUMMARY
1.1 Scope and Purpose
2.1 Facility Conditions
3.1 Findings and Conclusions
4.0 ASBESTOS ASSESSMENT DATA
5.0 CONCLUSIONS
Appendix 1- Site Location Plan and Sample Location Plan Appendix 2- Photographs Appendix 3- Laboratory Results Appendix 4- License
1.0 SIGNATURE PAGE
This report has been performed at the request of Mr. Sam LoFaso with Horry County Government. The inspection was conducted by Mrs. Dawn Schoolcraft with Asbestos Inspections, LLC on April 03, 2023.
The report was prepared and reviewed by the undersigned inspector.
Inspection Performed by: SCDEHC# Signature Date
Dawn Schoolcraft BI-00738 Dawn Schoolcraft April 03, 2023
Report Prepared by:
Dawn Schoolcraft BI-00738 Dawn Schoolcraft April 20, 2023
Report Reviewed by:
Dawn Schoolcraft BI-00738 Dawn Schoolcraft April 20, 2023
2.0 COVER LETTER
Mr. Sam LoFaso with Horry County Government 1515 Fourth Avenue Conway, South Carolina 29526
Subject:
Asbestos Inspection Report 3847 Woodridge Circle Little River, South Carolina 29566 Asbestos Inspections, LLC Project # 2023-01-108
Asbestos Inspections, LLC has completed an Asbestos Assessment and Inspection for the structure located at 3847 Woodridge Circle, in Little River, South Carolina. The inspection was completed on April 03, 2023 by a South Carolina Department of Health and Environmental Control (SCDHEC) building inspector.
The following report summarizes the project background, assessment procedures, results, and conclusions. The results presented in this report are indicative of conditions during the time of the inspection and of the specific areas outlined. The information provided in this report should not be used as a bidding document and field conditions should be verified. Should suspect building materials, not included within this report, be identified or impacted during the destructive activities, bulk samples must be collected and analyzed for asbestos content.
I appreciate this opportunity to provide my services. Should you have any questions concerning this report, please contact me at (843) 995-5197.
Sincerely, Asbestos Building Inspector (SCDHEC #BI-00738)
3.0 EXECUTIVE SUMMARY
1.1 Scope and Purpose
Mr. Sam LoFaso with Horry County Government requested this assessment for the structure located at 3847 Woodridge Circle in Little River, South Carolina. Based on information obtained from you, the structure is scheduled for demolition. The purpose of this assessment was to identify asbestos containing materials (ACMs) prior to demolition.
The inspection was completed in accordance with procedures specified in SCDHEC regulation 61.86.1 along with Occupational Safety and Health Administration (OSHA) regulation 29 Code of the Federal Regulations (CFR) 1926. The representative bulk samples collected were analyzed by a National Voluntary Laboratory Accreditation Program (NVLAP) certified laboratory which is administered by the National Institute of Standards and Technology (NIST). This report has been prepared in accordance with Environmental Protection Agency (EPA) 40 CFR, 763.85(a)(4).
2.1 Facility Conditions
The subject structure is an approximately 1152 square-feet mobile home. The exterior consists of vinyl siding, metal framed windows, and a former asphalt shingled roof. The shingles have been removed but were found in several piles around the home – vapor barrier is currently on the roof. The interior consists of drywall walls and ceilings, vinyl plank floor, carpeting, vinyl sheet floor, and ceramic tile. It appears that renovations were underway but were stopped. The home has sustained heavy vandalism resulting in damaged condition to the interior.
Suspect materials sampled during this inspection consists of drywall with associated joint compound, texture ceiling, sheet floor, tarpaper, and roofing materials.
The possibility exists that suspect materials were undetected in inaccessible areas such as areas deemed unsafe to enter, underneath or behind contents of units, behind exterior veneer, pipe chases, or wall voids. If additional suspect materials not included in this report are discovered during demolition, bulk samples should be collected and analyzed for asbestos content.
3.1 Findings and Conclusions
The EPA and SCDHEC define materials as asbestos containing if an asbestos content >1% is identified in a representative sample. No asbestos >1% was detected in the suspect materials collected and analyzed:
Material ID Material Regulatory Result Highest Analytical Result Est. Quantity There are no homogenous materials for this project that have tested positive containing asbestos
A copy of this report along with a demolition application should be submitted to SCDHEC at least 10 working days prior to any demolition activities. Additionally, a copy of this report should be provided to the contractors to assist with compliance with applicable State and Federal regulations.
The results presented in this report are indicative of conditions during the time of the assessment. The information provided in this report should not be used as a bidding document and field conditions and quantities should be verified.
4.0 ASBESTOS ASSESSMENT DATA
The assessment was performed by observing and sampling suspect ACMs in the unit prior to the scheduled renovations. Representative bulk samples were then extracted, recorded on a chain of custody, and submitted to Eurofins/CEI Labs of Cary, North Carolina for laboratory analysis. The samples were tested via Polarized Light Microscopy (PLM); however, SCDHEC requires a Transmission Electron Microscopy (TEM) test be performed for all non-friable organically bound material found negative via PLM.
The following tables exhibits the suspect material sampled, location, quantity of material sampled, condition of material, potential for future disturbance, and laboratory analysis.
All Materials Sampled
Material Id
Material Space Name
Quantity Material Category
Current Condition
Friability Damage Potential
Physical Assessment Category
Texture/Joint Compound/
Drywall
Addition Walls and Ceilings
800 sq. ft.
Surfacing Material
Significantly Damaged
Friable
(RACM)
Potential for
Significant Damage
Texture/ Drywall
Ceilings Throughout
Except Addition
1000 sq.
ft.
Surfacing Material
Good (No Damage)
Friable
(RACM)
Potential for
Significant Damage
Drywall/Joint
Compound
Walls Throughout
Except Addition
2200 sq.
ft.
Surfacing Material
Good (No Damage)
Friable
(RACM)
Potential for
Significant Damage
004 Sheet Floor
Hall Bathroom and Closet
– Under Ceramic
Tile
80 sq. ft. Miscellaneous Good (No Damage)
Category I Nonfriable
Potential for
Significant Damage
005 Tarpaper
Living Room and
Den – Under Vinyl
Plank Floor and Siding
2500 sq.
ft.
Miscellaneous Good (No Damage)
Category I Nonfriable
Potential for
Significant Damage
Material Id
Material Space Name
Quantity Material Category
Current Condition
Friability Damage Potential
Physical Assessment Category
006 Shingle Ground
Outside of Home
600 sq. ft.
Remnants
Miscellaneous Significantly
Damaged Category I Nonfriable
Potential for
Significant Damage
Sample Results
Sample # Material % Mineral Type Regulatory Result Analysis Type
001A White Texture ND ND Tested Negative by Lab PLM
White Joint Compound ND ND Tested Negative by Lab PLM White Drywall ND ND Tested Negative by Lab PLM
001B White Texture ND ND Tested Negative by Lab PLM
White Joint Compound ND ND Tested Negative by Lab PLM White Drywall ND ND Tested Negative by Lab PLM
001C White Texture ND ND Tested Negative by Lab PLM
White Joint Compound ND ND Tested Negative by Lab PLM White Drywall ND ND Tested Negative by Lab PLM
002A White Texture ND ND Tested Negative by Lab PLM White Drywall ND ND Tested Negative by Lab PLM
002B White Texture ND ND Tested Negative by Lab PLM White Drywall ND ND Tested Negative by Lab PLM
002C White Texture ND ND Tested Negative by Lab PLM White Drywall ND ND Tested Negative by Lab PLM
002D White Texture ND ND Tested Negative by Lab PLM White Drywall ND ND Tested Negative by Lab PLM
002E White Texture ND ND Tested Negative by Lab PLM White Drywall ND ND Tested Negative by Lab PLM
003A White Joint Compound ND ND Tested Negative by Lab PLM White Joint Compound ND ND Tested Negative by Lab PLM
White Drywall ND ND Tested Negative by Lab PLM
003B White Joint Compound ND ND Tested Negative by Lab PLM White Joint Compound ND ND Tested Negative by Lab PLM
White Drywall ND ND Tested Negative by Lab PLM
003C White Joint Compound ND ND Tested Negative by Lab PLM White Joint Compound ND ND Tested Negative by Lab PLM
White Drywall ND ND Tested Negative by Lab PLM
003D White Joint Compound ND ND Tested Negative by Lab PLM White Joint Compound ND ND Tested Negative by Lab PLM
White Drywall ND ND Tested Negative by Lab PLM
003E White Joint Compound ND ND Tested Negative by Lab PLM White Joint Compound ND ND Tested Negative by Lab PLM
White Drywall ND ND Tested Negative by Lab PLM 004A Off-white, Gray Sheet Floor ND ND Tested Negative by Lab PLM 004B Off-white, Gray Sheet Floor ND ND Tested Negative by Lab PLM 004C Off-white, Gray Sheet Floor ND ND Tested Negative by Lab TEM 005A Black Tarpaper ND ND Tested Negative by Lab PLM 005B Black Tarpaper ND ND Tested Negative by Lab PLM 005C Black Tarpaper ND ND Tested Negative by Lab TEM
Sample # Material % Mineral Type Regulatory Result Analysis Type 006A Black Shingle ND ND Tested Negative by Lab PLM 006B Black Shingle ND ND Tested Negative by Lab PLM 006C Black Shingle ND ND Tested Negative by Lab TEM
Please understand that quantities are estimated and should not be used for bidding purposes. Field conditions should be verified prior to bidding.
Site location plan and sample location plan is identified as Figures 1 and 2 in Appendix 1 of this report, photographs are in Appendix 2, laboratory results are in Appendix 3, and license is in Appendix 4.
5.0 CONCLUSIONS
The EPA and SCDHEC define materials as asbestos containing if an asbestos content >1% is detected in a representative sample. No asbestos >1 % was detected in the suspect materials sampled and analyzed for the structure located at 3847 Woodridge Circle in Little River, South Carolina:
Material ID Material Regulatory Result Highest Analytical Result Est. Quantity There are no homogenous materials for this project that have tested positive containing asbestos
A copy of this report along with a demolition application should be submitted to SCDHEC at least 10 working days prior to any demolition activities. Additionally, a copy of this report should be provided to the contractors to assist with compliance with applicable State and Federal regulations.
The possibility exists that suspect materials were undetected in inaccessible areas such as areas deemed unsafe to enter, behind exterior veneer, pipe chases, or wall voids. If additional suspect materials not included in this report are discovered during renovations, bulk samples should be collected and analyzed for asbestos content.
APPENDIX 1
Site Location Plan and Sample Location Plan
Site Location Plan 3847 Woodridge Cir Little River, SC Project # - 2023-01-108
Scale: Not to Scale Reviewed By: DS Date: 4/4/23 Source: N/A
Figure 1
Subject Property
Asbestos Sample Location Plan 3847 Woodridge Cir Little River, SC Project # - 2023-01-108
Figure 2 Scale: Not to Scale Reviewed By: DS Date: 4/4/23 Source: N/A
Figure 2
LEGEND
Sample Location
Asbestos Containing Sample Location
001A
Kitchen
Laundry
Bath
Master BedroomLiving Room BedroomBedroom
Bath Dining Room
Addition
001C
001B
004A
004B-C
003D
003C
003B
003A 003E
002B 002A
002C
002D
002E
005A
005B
005C
006A006B006C
APPENDIX 2
Photographs
Site Photos
Exterior Front
Exterior Rear
Exterior, Roof
Exterior Front
Interior Front Addition
Bedroom
Bathroom
Bedroom
APPENDIX 3
Laboratory Results
April 14, 2023
Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
CLIENT PROJECT: 3847 Woodbridge Cir
CEI LAB CODE: B237427
Dear Customer:
Enclosed are asbestos analysis results for PLM Bulk samples received at our laboratory on April 4, 2023. The samples were analyzed for asbestos using polarizing light microscopy (PLM) per the EPA 600 Method.
Sample results containing >1% asbestos are considered asbestos-containing materials (ACMs) per EPA regulatory requirements. The detection limit for the EPA 600 Method is <1% asbestos by weight as determined by visual estimation.
Thank you for your business and we look forward to continuing good relations.
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Tianbao Bai, Ph.D., CIH Laboratory Director
Kind Regards, ASBESTOS ANALYTICAL REPORT
By: Polarized Light Microscopy
Prepared for
Asbestos Inspections LLC
CLIENT PROJECT:
LAB CODE:
TEST METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
REPORT DATE:
TOTAL SAMPLES ANALYZED:
# SAMPLES >1% ASBESTOS:
3847 Woodbridge Cir
04/14/23
B237427
730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Asbestos Report Summary By: POLARIZING LIGHT MICROSCOPY
PROJECT: 3847 Woodbridge Cir LAB CODE: B237427
Client ID Lab ID Color Sample Description
ASBESTOS
%Layer
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
001A Layer 1 B237427.01 White Texture None Detected001A
Layer 2 B237427.01 White Joint Compound None Detected
Layer 3 B237427.01 White Drywall None Detected
001B Layer 1 B237427.02 White Texture None Detected001B
Layer 2 B237427.02 White Joint Compound None Detected
Layer 3 B237427.02 White Drywall None Detected
001C Layer 1 B237427.03 White Texture None Detected001C
Layer 2 B237427.03 White Joint Compound None Detected
Layer 3 B237427.03 White Drywall None Detected
002A Layer 1 B237427.04 White Texture None Detected002A
Layer 2 B237427.04 White Drywall None Detected
002B Layer 1 B237427.05 White Texture None Detected002B
Layer 2 B237427.05 White Drywall None Detected
002C Layer 1 B237427.06 White Texture None Detected002C
Layer 2 B237427.06 White Drywall None Detected
002D Layer 1 B237427.07 White Texture None Detected002D
Layer 2 B237427.07 White Drywall None Detected
002E Layer 1 B237427.08 White Texture None Detected002E
Layer 2 B237427.08 White Drywall None Detected
003A Layer 1 B237427.09 White Joint Compound None Detected003A
Layer 2 B237427.09 White Joint Compound None Detected
Layer 3 B237427.09 White Drywall None Detected
003B Layer 1 B237427.10 White Joint Compound None Detected003B
Layer 2 B237427.10 White Joint Compound None Detected
Layer 3 B237427.10 White Drywall None Detected
003C Layer 1 B237427.11 White Joint Compound None Detected003C
Layer 2 B237427.11 White Joint Compound None Detected
Layer 3 B237427.11 White Drywall None Detected
003D Layer 1 B237427.12 White Joint Compound None Detected003D
Layer 2 B237427.12 White Joint Compound None Detected
Layer 3 B237427.12 White Drywall None Detected
Page 1 of 2730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Asbestos Report Summary
PROJECT: 3847 Woodbridge Cir LAB CODE: B237427
Client ID Lab ID Color Sample Description
ASBESTOS
%Layer
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
003E Layer 1 B237427.13 White Joint Compound None Detected003E
Layer 2 B237427.13 White Joint Compound None Detected
Layer 3 B237427.13 White Drywall None Detected
004A B237427.14 Off-white,Gray Sheet Floor None Detected004A
004B B237427.15 Off-white,Gray Sheet Floor None Detected004B
004C B237427.16 Sample Submitted for TEM Analysis
004C
005A B237427.17 Black Tarpaper None Detected005A
005B B237427.18 Black Tarpaper None Detected005B
005C B237427.19 Sample Submitted for TEM Analysis
005C
006A B237427.20 Black Shingle None Detected006A
006B B237427.21 Black Shingle None Detected006B
006C B237427.22 Sample Submitted for TEM Analysis
006C
Page 2 of 2730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
ASBESTOS BULK ANALYSIS
Lab Code: B237427 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 3847 Woodbridge Cir
Fibrous
White 001A
B237427.01
Heterogeneous
Non-fibrous Bound
50% 30% 20%
Binder Calc Carb Perlite
None Detected Layer 1
Texture
White Joint Compound
B237427.01 Homogeneous
Non-fibrous Bound
60% 40%
Binder Calc Carb
None DetectedLayer 2
White Drywall
B237427.01 15%Heterogeneous
Fibrous Bound
85%Cellulose Gypsum None DetectedLayer 3
White 001B
B237427.02
Heterogeneous
Non-fibrous Bound
50% 30% 20%
Binder Calc Carb Perlite
None Detected Layer 1
Texture
White Joint Compound
B237427.02 Homogeneous
Non-fibrous Bound
60% 40%
Binder Calc Carb
None DetectedLayer 2
White Drywall
B237427.02 15%Heterogeneous
Fibrous Bound
85%Cellulose Gypsum None DetectedLayer 3
White 001C
B237427.03
Heterogeneous
Non-fibrous Bound
50% 30% 20%
Binder Calc Carb Perlite
None Detected Layer 1
Texture
Page 1 of 7730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Lab Code: B237427 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 3847 Woodbridge Cir
Fibrous
White Joint Compound
B237427.03 Homogeneous
Non-fibrous Bound
60% 40%
Binder Calc Carb
None DetectedLayer 2
White Drywall
B237427.03 15%Heterogeneous
Fibrous Bound
85%Cellulose Gypsum None DetectedLayer 3
White 002A
B237427.04
Heterogeneous
Non-fibrous Bound
No joint compound present.
60% 35% 5%
Binder Calc Carb Paint
None Detected Layer 1
Texture
White Drywall
B237427.04 15%Heterogeneous
Fibrous Bound
85%Cellulose Gypsum None DetectedLayer 2
White 002B
B237427.05
Heterogeneous
Non-fibrous Bound
No joint compound present.
60% 35% 5%
Binder Calc Carb Paint
None Detected Layer 1
Texture
White Drywall
B237427.05 15%Heterogeneous
Fibrous Bound
85%Cellulose Gypsum None DetectedLayer 2
White 002C
B237427.06
Heterogeneous
Non-fibrous Bound
No joint compound present.
60% 35% 5%
Binder Calc Carb Paint
None Detected Layer 1
Texture
Page 2 of 7730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Lab Code: B237427 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 3847 Woodbridge Cir
Fibrous
White Drywall
B237427.06 15%Heterogeneous
Fibrous Bound
85%Cellulose Gypsum None DetectedLayer 2
White 002D
B237427.07
Heterogeneous
Non-fibrous Bound
No joint compound present.
60% 35% 5%
Binder Calc Carb Paint
None Detected Layer 1
Texture
White Drywall
B237427.07 15%Heterogeneous
Fibrous Bound
85%Cellulose Gypsum None DetectedLayer 2
White 002E
B237427.08
Heterogeneous
Non-fibrous Bound
No joint compound present.
60% 35% 5%
Binder Calc Carb Paint
None Detected Layer 1
Texture
White Drywall
B237427.08 15%Heterogeneous
Fibrous Bound
85%Cellulose Gypsum None DetectedLayer 2
White 003A
B237427.09
Heterogeneous
Non-fibrous Bound
60% 35% 5%
Binder Calc Carb Paint
None Detected Layer 1
Joint Compound
White Joint Compound
B237427.09 Homogeneous
Non-fibrous Bound
60% 40%
Binder Calc Carb
None DetectedLayer 2
Page 3 of 7730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Lab Code: B237427 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 3847 Woodbridge Cir
Fibrous
White Drywall
B237427.09 15%Heterogeneous
Fibrous Bound
85%Cellulose Gypsum None DetectedLayer 3
White 003B
B237427.10
Heterogeneous
Non-fibrous Bound
60% 35% 5%
Binder Calc Carb Paint
None Detected Layer 1
Joint Compound
White Joint Compound
B237427.10 Homogeneous
Non-fibrous Bound
60% 40%
Binder Calc Carb
None DetectedLayer 2
White Drywall
B237427.10 15%Heterogeneous
Fibrous Bound
85%Cellulose Gypsum None DetectedLayer 3
White 003C
B237427.11
Heterogeneous
Non-fibrous Bound
60% 35% 5%
Binder Calc Carb Paint
None Detected Layer 1
Joint Compound
White Joint Compound
B237427.11 Homogeneous
Non-fibrous Bound
60% 40%
Binder Calc Carb
None DetectedLayer 2
White Drywall
B237427.11 15%Heterogeneous
Fibrous Bound
85%Cellulose Gypsum None DetectedLayer 3
Page 4 of 7730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Lab Code: B237427 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 3847 Woodbridge Cir
Fibrous
White 003D
B237427.12
Heterogeneous
Non-fibrous Bound
60% 35% 5%
Binder Calc Carb Paint
None Detected Layer 1
Joint Compound
White Joint Compound
B237427.12 Homogeneous
Non-fibrous Bound
60% 40%
Binder Calc Carb
None DetectedLayer 2
White Drywall
B237427.12 15%Heterogeneous
Fibrous Bound
85%Cellulose Gypsum None DetectedLayer 3
White 003E
B237427.13
Heterogeneous
Non-fibrous Bound
60% 35% 5%
Binder Calc Carb Paint
None Detected Layer 1
Joint Compound
White Joint Compound
B237427.13 Homogeneous
Non-fibrous Bound
60% 40%
Binder Calc Carb
None DetectedLayer 2
White Drywall
B237427.13 15%Heterogeneous
Fibrous Bound
85%Cellulose Gypsum None DetectedLayer 3
Off-white,Gray Sheet Floor004A
B237427.14 15%Heterogeneous
Fibrous Bound
50% 35%
Fiberglass Vinyl Binder
None Detected
Page 5 of 7730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
Lab Code: B237427 Date Received: 04-04-23 Date Analyzed: 04-14-23 Date Reported: 04-14-23
Client ID Lab ID
Lab Attributes
Lab Description
ASBESTOS
ASBESTOS BULK PLM, EPA 600 METHOD
NON-ASBESTOS COMPONENTS
Non-Fibrous
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 3847 Woodbridge Cir
Fibrous
Off-white,Gray Sheet Floor004B
B237427.15 15%Heterogeneous
Fibrous Bound
50% 35%
Fiberglass Vinyl Binder
None Detected
Sample Submitted for TEM Analysis
004C B237427.16
Black Tarpaper005A
B237427.17 70%Homogeneous
Fibrous Bound
30%Cellulose Tar None Detected
Black Tarpaper005B
B237427.18 70%Homogeneous
Fibrous Bound
30%Cellulose Tar None Detected
Sample Submitted for TEM Analysis
005C B237427.19
Black Shingle006A
B237427.20 30%Heterogeneous
Fibrous Bound
60% 10%
Fiberglass Tar Gravel
None Detected
Black Shingle006B
B237427.21 30%Heterogeneous
Fibrous Bound
60% 10%
Fiberglass Tar Gravel
None Detected
Sample Submitted for TEM Analysis
006C B237427.22
Page 6 of 7730 SE Maynard Road • Cary, NC 27511 • 919.481.1413
LEGEND: Non-Anth = Non-Asbestiform Anthophyllite Non-Trem = Non-Asbestiform Tremolite Calc Carb = Calcium Carbonate
METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
REPORTING LIMIT: <1% by visual estimation
REPORTING LIMIT FOR POINT COUNTS: 0.25% by 400 Points or 0.1% by 1,000 Points
REGULATORY LIMIT: >1% by weight
Due to the limitations of the EPA 600 method, nonfriable organically bound materials (NOBs) such as vinyl floor tiles can be difficult to analyze via polarized light microscopy (PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request.
This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results.
Interpretation of the analytical results is the sole responsibility of the client. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.
Information provided by customer includes customer sample ID and sample description.
ANALYST: APPROVED BY:
Tianbao Bai, Ph.D., CIH Laboratory Director
Ryan Steele
April 18, 2023
Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
CLIENT PROJECT: 3847 Woodbridge Cir
LAB CODE: T230879
Dear Customer:
Enclosed are asbestos analysis results for TEM bulk samples received at our laboratory on April 11, 2023. The samples were analyzed for asbestos using transmission electron microscopy (TEM) per Chatfield/EPA 600/R-93/116 Sec. 2.5.5.1 method.
Sample results containing > 1% asbestos are considered asbestos-containing materials (ACMs) per the EPA regulatory requirements. The detection limit for the TEM Chatfield/EPA 600/R-93/116 Sec. 2.5.5.1 method is <1% depending on the processed weight and constituents of the sample.
Thank you for your business and we look forward to continuing good relations.
Tianbao Bai, Ph.D., CIH Laboratory Director
Kind Regards, ASBESTOS ANALYTICAL REPORT
By: Transmission Electron Microscopy
Prepared for
Asbestos Inspections LLC
CLIENT PROJECT:
LAB CODE:
TEST METHOD: Bulk Chatfield EPA 600 / R93 / 116 Sec. 2.5.5.1
REPORT DATE:
3847 Woodbridge Cir
04/18/23
T230879
By: TRANSMISSION ELECTRON MICROSCOPY
Lab Code: T230879 Date Received: 04-11-23 Date Analyzed: 04-17-23 Date Reported: 04-18-23
Client ID Lab ID
Material Description
TEM BULK CHATFIELD / EPA 600 / R93 / 116 Sec. 2.5.5.1
Client: Asbestos Inspections LLC 4686 Peedee Hwy Conway, SC 29527
Project: 3847 Woodbridge Cir
Sample Weight
(g)
Organic Material
Acid Soluble Material
Acid Insoluble Material
Asbestos
T57914 004C Sheet Floor 0.237 64.1 17.3 18.6 None
Detected
T57915 005C Tarpaper 0.487 95.1 3.5 1.4 None
Detected
T57916 006C Shingle 0.586 21.2 43 35.8 None
Detected
LEGEND: None
METHOD: CHATFIELD & EPA/600/R-93/116 Sec. 2.5.5.1
LIMIT OF DETECTION: Varies with the weight and constituents of the sample (<1%)
REGULATORY LIMIT: >1% by weight
This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI (ECEI). ECEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results.
Interpretation of the analytical results is the sole responsibility of the client. Estimated measurement of uncertainty is available on request and in compliance with regulatory requirements. Samples were received in acceptable condition unless otherwise noted.
Information provided by customer includes customer sample ID, location, volume and area as well as date and time of sampling.
ECEI recommends between 0.20 and 0.50 grams of sample material for TEM bulk analysis.
Any weight below 0.10 grams is considered below protocol guidelines.
**Indicates sample weight below 0.05 grams and is considered insufficient for quantitative analysis.
ANALYST: APPROVED BY:
Tianbao Bai, Ph.D., CIH Laboratory Director
Stacy Ulrich
APPENDIX 4
License
12884, 06/30/2023, North Carolina, Dawn
Schoolcraft
1909008, 09/30/2023, South Carolina, Dawn
LBP-R-I162035-2, 03/16/2024, South Carolina, BI-00738, 06/06/2023, South Carolina, Dawn
File details come from the government source that posted it. Updated .