About this file

This document outlines a federal contract opportunity for renovations at a Veterans Affairs medical center. The solicitation calls for converting patient rooms to private rooms at Building 204 of the South Texas VA Health Care System. The work includes furnishing all materials, labor, tools, equipment, and other incidentals necessary to complete the conversion. The contract value is estimated between $1 million and $2 million. This opportunity is reserved exclusively for Service-Disabled Veteran-Owned Small Businesses and potential awardees must be verified as such by the Department of Veterans Affairs Center for Verification and Evaluation. The point of contact listed for any questions is Lynn Pettit of the Veterans Affairs agency.

View the file

Other files

File Type Posted
36C25722B0028 0003.docx DOCX document
Project Walk Through Sign In Sheet.pdf PDF
Bid Schedule B - project 674-18-103 Add Alternate.pdf PDF
36C25722B0028 0002.docx DOCX document
36C25722B0028 0001.docx DOCX document
TEMPLE_CONVERT_BLDG204_PATIENT_RMS_TECH-PLANS Model 08-20-2020.pdf PDF
2020-1_3.pdf PDF
2020-1_1.pdf PDF
100 percent Sealed ARCH SPECS TEMPLE CONVERT 204 VOL 2.pdf PDF
100 percent Sealed ARCH SPECS TEMPLE CONVERT 204 VOL 1.pdf PDF
122220_1.pdf PDF
36C25722B0028_1.docx DOCX document
Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

(TYP. OF 2)

S2

S1

S1

12/20

RE

1M3

MA

CHR

CHS

SP

(NAME)

LA

HWR

HWS

MG

A

LOX

A30

GV

HG

O

RO

F

G

DI

SW

D

AW

AV

MECHANICAL SYMBOLS AND ABBREVIATIONS

CHECK VALVE (AS SPECIFIED)

DUCT SECTION, SUPPLY AIR: UP, DOWN

DUCT SECTION, RETURN AIR OR EXHAUST: UP, DOWN

CHANGE OF ELEVATION, OFFSET, UP OR DOWN (DN)

HIGH EFFICIENCY TAKE-OFF WITH DAMPER, WITHOUT DAMPER

SMOKE FIRE DAMPER, HORIZONTAL

MANUAL VOLUME DAMPER (TYPE INDICATED)

ACCESS DOORS, VERTICAL OR HORIZONTAL

DUCT SECTION, OUTSIDE AIR: UP, DOWN

DUCT SIZE, FIRST FIGURE IS SIDE SHOWN

BDD

SFD

SFD

FD

FD

OR

SMOKE FIRE DAMPER, VERTICAL

FIRE DAMPER, HORIZONTAL

BACK DRAFT DAMPER

MOTORIZED DAMPER

FIRE DAMPER, VERTICAL

OBD

OR

VD

TURNING VANES

TRANSITION

FLEXIBLE DUCT

AD

DN

O.S.

FLEXIBLE CONNECTION

M

D

CAP

WELDED FITTING

FLANGED FITTING

DIAPHRAGM (PNEUMATIC ACTUATOR)

SCREWED FITTING

S

M

G

REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER

LEVER (MANUAL)

MOTOR (ELECTRIC ACTUATOR)

SOLENOID (ELECTRIC ACTUATOR)

MOTOR (PNEUMATIC ACTUATOR)

STEM (MANUAL)

DOUBLE CHECK BACKFLOW PREVENTER

GEAR (MANUAL)

SHUT OFF VALVE (AS SPECIFIED)

PRESSURE RELIEF VALVE

PRESSURE REDUCING VALVE

THREE WAY VALVE

OSSY VALVE WITH TAMPER SWITCH

GLOBE VALVE

GATE VALVE

SOIL, WASTE OR SANITARY SEWER

FIRE PROTECTION WATER SUPPLY

LOW TEMPERATURE HOT WATER RETURN

LOW TEMPERATURE HOT WATER SUPPLY

COMPRESSED AIR (PRESSURE NOTED)

HOT WATER RECIRCULATING

MEDICAL COMPRESSED AIR

DUCTWORK SYMBOLS

CHILLED WATER RETURN

CHILLED WATER SUPPLY

LABORATORY COMPRESSED AIR

AUTOMATIC SPRINKLER

EXISTING PIPE

PIPE TO BE REMOVED

GAS - MEDIUM PRESSURE

OXYGEN

GAS VENT

LIQUID OXYGEN

COMPRESSED AIR

GAS - HIGH PRESSURE

HOT WATER (TEMP. INDICATED)

SOFT WATER

DEIONIZED WATER

REVERSE OSMOSIS

GAS - LOW PRESSURE

PIPING SYMBOLS

ACID WASTE

ACID VENT

INDIRECT DRAIN

COLD WATER

HOT WATER

VENT

MECHANICAL SYMBOLS

AIR QUANTITY (CFM)

GRILLE QUANTITY

TYPE MARK (S=SUPPLY,

R=RETURN, E=EXHAUST)

GRILLE IDENTIFICATION

ANGLE VALVE

BUTTERFLY VALVE

BALANCING VALVE (AS SPECIFIED)

BALL VALVE

SIDEWALL GRILLE OR REGISTER (TYPE INDICATED)

CEILING GRILLE OR REGISTER (TYPE INDICATED)

LOUVER (MARK INDICATED)

TEE WITH SPLITTER DAMPER & PULLROD

DUCTWORK SYMBOLS (CONT.)

STANDARD BRANCH, SUPPLY OR RETURN, NO SPLITTER

MANUAL SPLITTER

OFFSET

REFER TO DETAIL 2, SHT. M-1

DRAWING SYMBOLS

EQUIPMENT MARK

SECTION REFERENCE

WALL CLEANOUT

YARD CLEANOUT OR CLEANOUT TO GRADE

DOUBLE YARD CLEANOUT OR CLEANOUT TO GRADE

DYCO

YCO

WALL HYDRANT OR RECESSED BOX HOSE BIBB

WCO

FCO

WH

HB

CLEANOUT PLUG

FLOOR CLEANOUT

THERMOMETER WELL, ONLY

PRESSURE GAUGE AND COCK

OUTLET, TYPE INDICATED

THERMOMETER

F&T

OFM-1

VFM-1

EJ-1

STEAM TRAPS (INDICATE TYPE)

VENTURI FLOWMETER

ORIFICE PLATE

EXPANSION JOINT

FLEXIBLE CONNECTOR

EXPANSION LOOP

NOTE: NOT ALL SYMBOLS OR

ABBREVIATIONS MAY BE USED.

RE: 2M1

DUCT OR PIPE TEMP. SENSOR (PROVIDE 12" MIN.

DUCT STATIC PRESSURE SENSOR

DUCT TEMP. SENSOR WITH AVERAGING ELEMENT

LENGTH IN DUCT WHEN SPACE PERMITS)

REFRIGERANT SENSOR

PRESSURE SWITCH

DUCT HUMIDITY SENSOR

DUCT DEWPOINT SENSOR

ROOM THERMOSTAT: TEMPERATURE, HUMIDITY

ROOM SENSOR: TEMPERATURE, HUMIDITY

REMOTE BULB THERMOSTAT

DUCT OR PIPE THERMOSTAT ( PROVIDE 12"

MIN. LENGTH IN DUCT WHEN SPACE PERMITS)

DUCT THERMOSTAT WITH AVERAGING ELEMENT

CONTROLS

MECHANICAL SYMBOLS (CONT.)

SIDEWALL FIRE SPRINKLER HEAD

PENDANT FIRE SPRINKLER HEAD

UPRIGHT FIRE SPRINKLER HEAD

SMOKE DETECTOR

DRAIN (TYPE NOTED)

HEAT DETECTOR

VARIABLE SPEED MOTOR CONTROLLER

CWP-1

AV

MV

ALIGNMENT GUIDE

PUMP (INDICATE USE)

ANCHOR

BALL JOINT

AUTOMATIC AIR VENT

STRAINER W/ BLOW OFF

MANUAL AIR VENT

TEE

OUTLET UP TEE

SCREWED UNION

OUTLET DOWN TEE

FLANGED UNION

ECCENTRIC STRAIGHT CROWN REDUCER

ECCENTRIC STRAIGHT INVERT REDUCER

CROSS

FLOW SWITCH

MECHANICAL SYMBOLS (CONT.)

R

PITCH OF PIPE, RISE (R) DROP (D)

TURNED UP ELBOW

TURNED DOWN ELBOW

CONCENTRIC REDUCER

P

SC

P

FS

RS

T

SP

DP

H

T

T

T

T

T

T

H

H

SD

HD

FD

M

L-1

AHU-12

P R

O J E

C T

7700 Torino St, Suite 101

San Antonio, TX 78229 Telephone: 210.614.1110

© 2020 Alderson & Associates, Inc.

F-1008

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Central Texas Veterans Health

Care System

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

PROJECT MANAGEMENT STAMPCONSULTANT

321 4 5 6 7 8 9 10

FULLY SPRINKLERED

CONSTRUCTION BID

DOCUMENTS

B

IM

/1

-1

T e m p le

V A

C o n v e rt

P a ti e n t R o o m s B ld g

/1

T e m p le

V A

B

M .r v t

/8

/2

:4 :1

P

M

M0.0

MECHANICAL SYMBOLS &

ABBREVIATIONS

CONVERT BUILDING 204

PATIENT ROOMS TO

PRIVATE ROOMS

1901 VETERANS MEMORIAL DRIVE TEMPLE,

TX. 76504

10/09/20 MTK RMP

674-18-103

GENERAL MECHANICAL NEW WORK NOTES

1. ALL WORK SHALL BE IN ACCORDANCE WITH THE 2018 INTERNATIONAL

BUILDING CODE,THE 2018 INTERNATIONAL MECHANICAL CODE, VA DESIGN GUIDE,

AND THE OTHER CODES AND ORDINANCES OF THE AUTHORITY HAVING

JURISDICTION.

2. NEW DUCT DIMENSIONS INDICATED ARE INSIDE DIMENSIONS CLEAR.

3. ALL NEW RECTANGULAR SUPPLY AND RETURN DUCTS SHALL HAVE TURNING

VANES AT EACH 90 DEGREE ELBOW OR TEE.

4. ALL NEW DUCT SHALL BE SHEETMETAL AND SHALL BE INSTALLED WITH

INSULATION AS SPECIFIED.

5. ALL NEW DUCTWORK SHALL BE FABRICATED AND INSTALLED AS PER ASHRAE

AND SMACNA STANDARDS.

6. MOUNT ALL NEW THERMOSTATS/SENSORS AT 3'-8" A.F.F.

7. PROVIDE AND INSTALL A VOLUME CONTROL DAMPER ON EACH BRANCH

DUCT SERVING A DIFFUSER/REGISTER/GRILLE.

8. COORDINATE ALL NEW DUCTWORK, GRILLES, AND EQUIPMENT WITH ALL

TRADES BEFORE INSTALLING.

9. TRANSITION NEW SUPPLY, RETURN AND EXHAUST DUCTS FROM UNIT CONNECTION

SIZE TO DUCT SIZE SHOWN.

10. PROVIDE AND INSTALL VIBRATION ISOLATORS ON ANY NEW EQUIPMENT WITH

MOVING PARTS.

11. DUCT SMOKE DETECTORS TO BE PROVIDED AND INSTALLED BY THE

FIRE ALARM SYSTEMS INSTALLER. COORDINATE WITH MECHANICAL

CONTRACTOR. INSTALL DETECTOR IN RETURN DUCT NEAR UNIT

CONNECTION. THE MECHANICAL CONTRACTOR SHALL BE

RESPONSIBLE FOR WIRING BETWEEN THE FIRE ALARM LOW VOLTAGE

RELAY AND THE HVAC CONTROL EQUIPMENT.

12. ALL NEW UNITS MUST BE INSTALLED LEVEL.

13. PROVIDE CANVAS CONNECTION AT NEW UN-ISOLATED FAN DUCT

CONNECTIONS.

14. COORDINATE LOCATIONS OF NEW MECHANICAL EQUIPMENT WITH

GENERAL CONTRACTOR AND STRUCTURE, TYPICAL. WHERE SIGNIFICANT

CHANGES ARE REQUIRED, THE CONTRACTOR SHALL PRESENT POTENTIAL

MODIFICATIONS TO, AND OBTAIN APPROVAL FROM THE ENGINEER PRIOR

TO PROCEEDING WITH SAID WORK.

15. CAREFULLY PROTECT ALL EQUIPMENT AND MATERIAL PRIOR TO

INSTALLATION. SEE SPECIFICATIONS.

16. ALL NEW CONDENSATE DRAIN PIPING SHALL BE TYPE L COPPER, GRADE

PIPING AT 1/8" PER FOOT. (MIN.).

17. PROVIDE MANUFACTURER'S RECOMMENDED CLEARANCES FOR ALL

NEW MECHANICAL EQUIPMENT.

18. SIZE AND ROUTE NEW REFRIGERANT PIPING PER EQUIPMENT

MANUFACTURER'S RECOMMENDATIONS.

19. CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING OVER EXISTING

FLOORING, FURNITURE AND EQUIPMENT AS REQUIRED WHEN PERFORMING

WORK WITHIN AN AREA/ROOM. CONTRACTOR IS RESPONSIBLE FOR

DAMAGE CAUSED TO WALL FINISHES, FLOOR FINISHES, FURNITURE AND

EQUIPMENT. REPAIR DAMAGES OR REPLACE TO OWNER'S SATISFACTION

AT NO ADDITIONAL COST TO THE OWNER. CONTRACTOR SHALL PROVIDE

DUST BARRIERS WHERE REQUIRED TO PROHIBIT THE MIGRATION OF

AIRBORNE CONSTRUCTION DUST INTO OTHER OCCUPIED AREAS.

20. CONSTRUCTION ACTIVITIES SHALL NOT IMPEDE OR OBSTRUCT THE MEANS

OF EGRESS.

21. REFRIGERANT PIPING SHOWN AS SINGLE LINE FOR CLARITY.

22. EXISTING TO REMAIN DUCTWORK TO BE THOROUGHLY CLEANED PRIOR TO

COMPLETING CONSTRUCTION. PROVIDE NECESSARY DUCT ACCESS TO

ALLOW FOR CLEANING CONTRACTOR TO PROPERLY CLEAN THE INTERIOR

OF THE DUCTWORK.

23. PROVIDE FIRE SMOKE DAMPERS AT ALL SHAFT PENETRATIONS, SMOKE

COMPARTMENT WALL PENETRATIONS, ALL 2 HOUR RATED WALL PENETRATIONS,

ALL FLOOR PENETRATIONS, AND ALL SMOKE BARRIERS. COORDINATE POWER

24. MAINTAIN HYDRONIC WATER TREATMENT THROUGHOUT CONSTRUCTION.

THE WATER TREATMENT CONTRACTOR SHALL TAKE PRELIMINARY WATER

QUALITY READINGS, AND SHALL BRING TO AN ACCEPTABLE LEVEL PRIOR TO

DELIVERING TO NEW EQUIPMENT.

REQUIREMENTS WITH DIV 26 AND 28 CONTRACTORS. FIELD COORDINATE.

25. EXISTING TO REMAIN DUCTWORK TO BE RE-INSULATED WHERE INSULATION

IS DAMAGED OR REMOVED FOR CONSTRUCTION.

GENERAL MECHANICAL DEMOLITION NOTES

1. ALL WORK SHALL BE IN ACCORDANCE WITH THE 2018 INTERNATIONAL

BUILDING CODE,THE 2018 INTERNATIONAL MECHANICAL CODE, AND THE

OTHER CODES AND ORDINANCES OF THE AUTHORITY HAVING

JURISDICTION.

2. CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING OVER EXISTING

FLOORING, FURNITURE AND EQUIPMENT AS REQUIRED WHEN PERFORMING

WORK WITHIN A AREA/ROOM. CONTRACTOR IS RESPONSIBLE FOR

DAMAGE CAUSED TO WALL FINISHES, FLOOR FINISHES, FURNITURE AND

EQUIPMENT. REPAIR DAMAGES OR REPLACE TO OWNER'S SATISFACTION

AT NO ADDITIONAL COST TO THE OWNER. CONTRACTOR SHALL PROVIDE

DUST BARRIERS WHERE REQUIRED TO PROHIBIT THE MIGRATION OF

AIRBORNE CONSTRUCTION DUST INTO OTHER OCCUPIED AREAS, INCLUDING

3. CONSTRUCTION ACTIVITIES SHALL NOT IMPEDE OR OBSTRUCT THE MEANS

OF EGRESS.

4. ALL EXISTING SYSTEMS/EQUIPMENT SHALL REMAIN IN SERVICE UNLESS

OTHERWISE NOTED.

5. THE CONTRACTOR SHALL THOROUGHLY FAMILIARIZE THEMSELVES WITH

THE EXISTING FACILITY PRIOR TO BIDDING. ALL CONSTRUCTION MEANS

AND METHODS REQUIRED TO ACCOMMODATE EXISTING CONDITIONS,

PROJECT STANDARDS AND SPECIFICATIONS SHALL BE THE SOLE

RESPONSIBILITY OF THE CONTRACTOR.

6. THE CONTRACTOR SHALL VERIFY WITH THE OWNER THE CONDITION OF ALL

EXISTING EQUIPMENT AND SYSTEMS THAT ARE TO REMAIN IN SERVICE AND

PROVIDE A REPORT OF THEIR FINDINGS TO THE OWNER PRIOR TO THE START

OF CONSTRUCTION. REMEDIATION EFFORTS FOR ANY DEFICIENCIES FOUND

TO EXIST DURING THE CONSTRUCTION PERIOD SHALL, AT THE DISCRETION

OF THE OWNER, BE THE RESPONSIBILITY OF THE CONTRACTOR.

7. THE CONTRACTOR SHALL MAKE AVAILABLE ALL DEMOLISHED EQUIPMENT

AND FIXTURES TO THE OWNER. IN THE EVENT THAT THE OWNER REFUSES

ANY SAID EQUIPMENT OR FIXTURES, THE CONTRACTOR SHALL DISCARD SAID

MATERIALS AT THEIR OWN EXPENSE.

EXISTING TO REMAIN AREAS ON THE SAME FLOOR.

8. THE CONTRACTOR SHALL PROVIDE TEMPORARY COOLING AND HEATING TO

EXISTING TO REMAIN AREAS THAT WILL BE AFFECTED BY CONSTRUCTION

LONG TERM. MINIMIZE OUTAGES TO DUCTWORK AND PIPING SYSTEMS

SERVING TERMINAL UNITS.

PROPOSED PHASING PLAN:

• DEMOLITION AND NEW WORK SHALL BE PHASED TO

MINIMIZE HVAC, ELECTRICAL, AND PLUMBING OUTAGES

AND MINIMIZE THE REQUIREMENT FOR TEMPORARY

UTILITES. ALL OUTTAGES SHALL BE COORDINATED WITH

THE OWNERS SCHEDULE 4 WEEKS PRIOR TO CREATING

THE OUTTAGE.

• NEW SYSTEMS SHALL TIE INTO EXISTING SYSTEMS

WHERE PRACTICAL AND SHOWN ON THE PLANS. NEW

PIPING TIE IN POINTS SHALL BE HOT TAPPED TO MAINTAIN

OPERATION TO THE REMAINDER OF THE BUILDING.

DUCTWORK THAT SERVES EXISTING TO REMAIN SPACES

SHALL BE RE-ROUTED PRIOR TO SYSTEM CHANGEOVER.

• IT IS THE SOLE RESPONSIBILITY OF THE GENERAL

CONTRACTOR AND SUBCONTRACTOR TO PROVIDE A

FEASIBLE PHASING PLAN MAINTAIN BUILDING

OPERATIONS DURING CONSTUCTION. PRESENT SAID

PHASING PLAN TO OWNER AND DESIGN TEAM PRIOR TO

COMMENCING CONSTRUCTION. NO EXISTING TO REMAIN

PORTION OF THE BUILDING SHALL BE WITHOUT AIR

CONDITIONING FOR ANY PERIOD OF TIME UNLESS

COORDINATED WITH OWNER.

Revisions: Date: 10/13/20 MTK RMP

P R

O J E

C T

7700 Torino St, Suite 101

San Antonio, TX 78229 Telephone: 210.614.1110

© 2020 Alderson & Associates, Inc.

F-1008

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Central Texas Veterans Health

Care System

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

PROJECT MANAGEMENT STAMPCONSULTANT

321 4 5 6 7 8 9 10

FULLY SPRINKLERED

CONSTRUCTION BID

DOCUMENTS

B

IM

/1

-1

T e m p le

V A

C o n v e rt

P a ti e n t R o o m s B ld g

/1

T e m p le

V A

B

M .r v t

/8

/2

:4 :4

P

M

MD1.1

FOURTH FLOOR MECHANICAL

DEMOLITION PLAN - NORTH

CONVERT BUILDING 204

PATIENT ROOMS TO

PRIVATE ROOMS

1901 VETERANS MEMORIAL DRIVE TEMPLE,

TX. 76504

10/09/20 MTK RMP

674-18-103

Revisions: Date:

12x6

D

S W

T

T

T

T

D

T

D

D

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

W

T

T

T

T

T

T

T

T

T

T

T

T

T

24/25

T

T

VCWD

V C

W D

T

T

T

T

T

T

T

D

D

D

D

D

D

D

D

S W

P.E. Reg. No.

Engineer:

for permit, bidding or constructio

Document incomplete: Not inten

INTERIM REVIEW ONL

Dean Alderson

54441

Firm:

Alderson & Associates, F

SCALE: 1/8" = 1'-0"

4TH FLOOR MECHANICAL DEMOLITION PLAN - NORTH

N

10/13/20 MTK RMP

O J E

C T

7700 Torino St, Suite 101

San Antonio, TX 78229 Telephone: 210.614.1110

© 2020 Alderson & Associates, Inc.

F-1008

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Central Texas Veterans Health

Care System

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

PROJECT MANAGEMENT STAMPCONSULTANT

321 4 5 6 7 8 9 10

FULLY SPRINKLERED

CONSTRUCTION BID

DOCUMENTS

B

IM

/1

-1

T e m p le

V A

C o n v e rt

P a ti e n t R o o m s B ld g

/1

T e m p le

V A

B

M .r v t

/8

/2

:4 :4

P

M

MD1.2

FOURTH FLOOR MECHANICAL

DEMOLITION PLAN - SOUTH

CONVERT BUILDING 204

PATIENT ROOMS TO

PRIVATE ROOMS

1901 VETERANS MEMORIAL DRIVE TEMPLE,

TX. 76504

10/09/20 MTK RMP

674-18-103

Revisions: Date:

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

SP

SW

SW

SW

SW

SW SW

SW

SW

T

T

T

T

T

T

T

N

P.E. Reg. No.

Engineer:

for permit, bidding or construction.

Document incomplete: Not intended

INTERIM REVIEW ONLY

Dean Alderson

54441

Firm:

Alderson & Associates, F-1008

SCALE: 1/8" = 1'-0"

4TH FLOOR MECHANICAL DEMOLITION PLAN - SOUTH

O J E

C T

7700 Torino St, Suite 101

San Antonio, TX 78229 Telephone: 210.614.1110

© 2020 Alderson & Associates, Inc.

F-1008

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Central Texas Veterans Health

Care System

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

PROJECT MANAGEMENT STAMPCONSULTANT

321 4 5 6 7 8 9 10

FULLY SPRINKLERED

CONSTRUCTION BID

DOCUMENTS

B

IM

/1

-1

T e m p le

V A

C o n v e rt

P a ti e n t R o o m s B ld g

/1

T e m p le

V A

B

M .r v t

/8

/2

:4 :4

P

M

MD1.3

ENLARGED MECHANICAL ROOM

DEMOLITION PLAN

CONVERT BUILDING 204

PATIENT ROOMS TO

PRIVATE ROOMS

1901 VETERANS MEMORIAL DRIVE TEMPLE,

TX. 76504

10/09/20 MTK RMP

674-18-103

Revisions: Date:

A

D

A

D

A

D

A

D

A

D

SFDSFD

SFD

SFD

FD

SCALE: 1/4" = 1'-0"

FOURTH FLOOR MECHANICAL ROOM ENLARGED DEMOLITION PLAN

O J E

C T

7700 Torino St, Suite 101

San Antonio, TX 78229 Telephone: 210.614.1110

© 2020 Alderson & Associates, Inc.

F-1008

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Central Texas Veterans Health

Care System

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

PROJECT MANAGEMENT STAMPCONSULTANT

321 4 5 6 7 8 9 10

FULLY SPRINKLERED

CONSTRUCTION BID

DOCUMENTS

B

IM

/1

-1

T e m p le

V A

C o n v e rt

P a ti e n t R o o m s B ld g

/1

T e m p le

V A

B

M .r v t

/8

/2

:4 :4

P

M

MD2.1

FOURTH FLOOR MECHANICAL PIPING

DEMOLITION PLAN - NORTH

CONVERT BUILDING 204

PATIENT ROOMS TO

PRIVATE ROOMS

1901 VETERANS MEMORIAL DRIVE TEMPLE,

TX. 76504

10/09/20 Checker Author

674-18-103

Revisions: Date:

HWHR

HWHR

HWH

P.E. Reg. No.

Engineer:

for permit, bidding or construc

Document incomplete: Not int

INTERIM REVIEW ON

Dean Alderson

54441

Firm:

Alderson & Associates, SCALE: 1/8" = 1'-0"

4TH FLOOR MECHANICAL PIPING DEMOLITION PLAN - NORTH

O J E

C T

7700 Torino St, Suite 101

San Antonio, TX 78229 Telephone: 210.614.1110

© 2020 Alderson & Associates, Inc.

F-1008

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Central Texas Veterans Health

Care System

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

PROJECT MANAGEMENT STAMPCONSULTANT

321 4 5 6 7 8 9 10

FULLY SPRINKLERED

CONSTRUCTION BID

DOCUMENTS

B

IM

/1

-1

T e m p le

V A

C o n v e rt

P a ti e n t R o o m s B ld g

/1

T e m p le

V A

B

M .r v t

/8

/2

:4 :4

P

M

MD2.2

FOURTH FLOOR MECHANICAL PIPING

DEMOLITION PLAN - SOUTH

CONVERT BUILDING 204

PATIENT ROOMS TO

PRIVATE ROOMS

1901 VETERANS MEMORIAL DRIVE TEMPLE,

TX. 76504

10/09/20 Checker Author

674-18-103

Revisions: Date:

HWH

HWHR

N

P.E. Reg. No.

Engineer:

for permit, bidding or cons

Document incomplete: No

INTERIM REVIEW

Dean Alderson

54441

Firm:

Alderson & Associa

SCALE: 1/8" = 1'-0"

4TH FLOOR MECHANICAL PIPING DEMOLITION PLAN - SOUTH

VAV4J-18

VAV4J-15

VAV4J-10

VAV4J-9

VAV4J-6 VAV4J-2

VAV4K-1

VAV4K-2

VAV4K-4

VAV4J-17

VAV4J-11

VAV4J-20

VAV4K-21

R1

R1

R1

R1

R1

R1

R1

R1

R1

R1

R1

R1

R1

R1

R1

R1

R1

E3

E3

R1

S2

S1

S4

S4

S4

S4

S1

S2

S2

S1

S1

S2

S2

S2 110S2

S3

S1

S2

S2

S2

S2

S2

S3

S2

S2

S2

S2

S2 75S3

S2

S1

S1

S1

S3

S4

S1

S1

S3

S3

S1

S2

S1

S2

S3 330S3

S3

S3

S3

S3

S3

S1

S2

S1

S3

S2

S2 85 S1

S2

S4

S2

S3

S2

S4

S2

E1

E1

E1

E1

E1

E1

E1

E3

R1

E1

E1

E1

E1

E1

E3

E3

E1

E1

E1

E1

E1

R1

S1

S2

S1

S3

S3

S3

"x

"x

"x

"x

"x

"x

42"x22"

42"x24" 44"x24" 52"x24"

52"x24"

46"x18"

36"x18" 35"x22"

ES1

ES2

ER1

ER2

EE1

ES1

ES1

ER2

ER2

ES1

ES1

ER2

ER2

ES1

ES1

ES1

ER2

ES1

VAV4J-23VAV4J-49

VAV4J-47

VAV4J-46

"x

"x

VAV4J-19

VAV4J-13

S1

VAV4J-8

VAV4J-3

"x

"x

"x

"x

48"x16"

"x

48"x14"

VAV4J-1

R1

"x

"x

"x

26"x14"

"x

"x

"x

VAV4K-5

R2

VAV4J-22

1 1

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

6 66

(TYP)

(TYP)

(TYP)

8"ø 6"ø 8"ø

12"x14"

"ø

18"x12"

"ø

"ø

"ø

12"x10"

"ø

"ø8"ø

6"ø

"x

6"ø

"ø

"ø

10"ø

"x

8"ø

10"ø

"x

6"x6"6 "ø

8"ø

8"ø

"x

14"x12"

"ø6 "ø

10"x8"

6"x6"

16"x12"

16"x12"

18"x12"

"x

8"x6"8"x6"

"x

8"x6"

"ø

6"x6"

8"ø6"x6"

6"x6"

"x

6"ø

10"ø

"x

6"ø

8"ø

"x

"x

10"ø

6"ø

"x

"x

8"ø

8"ø

"x

8"ø

8"ø

10"x12"

"ø

"ø ø10"

10"ø

"ø

8"ø

10"x12"

"ø 1

"ø

8"ø

12"x12"

"ø

"ø

6"x6"

"x

6"x6"

"x

8"ø 10"x12"

"ø

"ø

8"ø

"ø

"ø

"x

"x

"x

"x

"x

"x

"x

"ø

"ø

12"x10"

"ø

12"x10"

"ø

8"x6"

"x

"x

10"x8"

8"ø

8"ø

12"x14"

12"x14"

"ø

"ø

8"ø

"ø

8"x6"

"x

8"x6"

ITU4J-1

ITU4J-2

8"x6"

"x

14"x10"

14"x10"

8"x6" 14"x10"

ITU4J-3

14"x10"

ITU4J-4

"x

ITU4K-2

10"x12"

VAV4J-16

12"x12"

10"x12"

VAV4J-14

10"x6"

10"x6"

10"x6"

(TYP)

R1

VAV4J-7 1

6"ø

6"ø

"x

E3

10"x8"

10"x8" E3

E3

"x

10"x8"

VAV4J-51

"x

10"x8"

10"x8"

VAV4J-12 1

10"x6" 14"x10"

VAV4J-4 1

E3

"x

E3

E3

E3

12"øE3

E3

E3

E3

VAV4K-3

12"ø

E3

E3 ø12"

E3

E3 33510"x12"

(TYP)

WY U R P N M H G FJ.5L EK J

STAIRS

PATIENT TOILET

4J22B

CLEAN UTILITY

4J29

STORAGE ROOM

4K04

ANTE ROOM

4J30A

ANTE ROOM

4J31A

PATIENT ROOM

(ISOLATION)

4J31

ANTE ROOM

4J32A

PATIENT ROOM

(ISOLATION)

4J32

ANTE ROOM

4J33A

PATIENT ROOM

(ISOLATION)

4J33

PATIENT ROOM

(ISOLATION)

4K37

PATIENT ROOM

(ISOLATION)

4K35

MECHANICAL

4K34

ELECTRICAL

4K06

H.A.C.

4K05

STORAGE ROOM

4J07

ANTE ROOM

4K37A

ANTE ROOM

4K36A

ANTE ROOM

4K35A

CONFERENCE

4J19

NOURISHMENT

4J16

REPORT ROOM

4J11

STAFF SUPPORT

ROOM

4J13

MEDICATION

PREP.

4J15

EQUIPMENT

4J28

SOILED UTILITY

4J27

PATIENT TOILET

4J09B

PATIENT TOILET

4J08B

PATIENT ROOM

4J08

PATIENT ROOM

4J09

PATIENT ROOM

4K03

PATIENT TOILET

4K03B

PATIENT TOILET

4J20B

PATIENT TOILET

4J21B

PATIENT ROOM

4J22

PATIENT ROOM

4J24

PATIENT ROOM

4J25

PATIENT ROOM

4J26

PATIENT ROOM

(ISOLATION)

4J30

PATIENT ROOM

4J20

PATIENT ROOM

4J21

CONFERENCE

ROOM

4J10

PATIENT TOILET

4J24B

PATIENT TOILET

4J25B

PATIENT TOILET

4J26B

PATIENT TOILET

4J31B

PATIENT TOILET

4J32B

PATIENT TOILET

4K36B

PATIENT TOILET

4K35B

PATIENT TOILET

4J33B

PATIENT TOILET

4J30B

"x

"ø

"ø

(TYP)

TL. COM. ROOM

4J12

PATIENT ROOM

4J23

PATIENT TOILET

4J23B

CLEAN LIN.

4J18

NURSE STATION

4J17

S2

10"x8"

"x

"x

"x

24"x14" 26"x14" 30"x14" 34"x14" 36"x14" 36"x18"

"x

10"x8"

"x

"ø

8"ø

10"ø 8"ø

"ø

"ø

S2

"x

"ø

8"ø

12"ø

20"x14"

24"x12"

"x

"x

8"x6"

14"x10"

"x

M1.1

20"x14"

"x

8"ø

VAV4J-24

S5

"x

"x

"ø

"x

ITU4K-1

"x

8"x8"

S5

"x

R2

"ø

"ø

"ø

"x

R1

12"x10"

"x

R1

"ø

12"ø

12"x10" R1

6"ø

"x

"x

TTTT

T

T

T

T

T

T

T

T

T

T

T

T T T

T

T

"x

R1

T

T

T

T

T

T

T

"x

10"x8"

"x

14"x10"

10"x8"

8"x6"

"x

6"x6"

"x

"ø

"x

"x

"x

"x

"x

"x

18"x12"

(TYP)

(TYP)

VAV4J-21

E3

10"ø

10"ø 12"x12"

VAV4K-19

"ø

"ø

10"ø

"x

VAV4J-19

VAV4J-18

VAV4J-17

VAV4J-16

VAV4J-14

VAV4J-15

VAV4J-13

VAV4J-12

VAV4J-20

VAV4J-11

101010

10 10

VAV4J-10

TVAV4J-9

VAV4J-3 VAV4J-8 VAV4J-6

VAV4J-2

VAV4J-7 VAV4J-5 VAV4J-4

VAV4J-1

VAV4J-21

"x

VAV4K-21

VAV4K-2

VAV4K-1

VAV4K-3

VAV4K-5

VAV4K-4

4TH FLOOR - NORTH

62' - 4"

5TH FLOOR

77' - 8"

PIPING/CONDUIT ROUTED

ABOVE DUCT

VAV4J-5

VAV4J-6

8"ø

8"ø

CORRIDOR PATIENT ROOMPATIENT ROOM

EXISTING

44"x24" SA

12"x12" SA

EXISTING

48"x16" RA

12"x12" SA

16"x14" SA

HOT WATER

PIPING

SUPPLY AIR

DEVICE

CABLE TRAY,

RE: TECH. DWGS.

12"x12" SARETURN AIR

DEVICE

P R

O J E

C T

7700 Torino St, Suite 101

San Antonio, TX 78229 Telephone: 210.614.1110

© 2020 Alderson & Associates, Inc.

F-1008

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Central Texas Veterans Health

Care System

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

PROJECT MANAGEMENT STAMPCONSULTANT

321 4 5 6 7 8 9 10

FULLY SPRINKLERED

CONSTRUCTION BID

DOCUMENTS

B

IM

/1

-1

T e m p le

V A

C o n v e rt

P a ti e n t R o o m s B ld g

/1

T e m p le

V A

B

M .r v t

/1

/2

:0

:1

A

M

M1.1

FOURTH FLOOR MECHANICAL FLOOR

PLAN - NORTH

CONVERT BUILDING 204

PATIENT ROOMS TO

PRIVATE ROOMS

1901 VETERANS MEMORIAL DRIVE TEMPLE,

TX. 76504

10/13/20 MTK RMP

674-18-103

SCALE: 1/8" = 1'-0"

FOURTH FLOOR MECHANICAL FLOOR PLAN - NORTH

1 MAINTAIN REQUIRED CLEARANCES ON ALL TERMINAL UNITS. TERMINAL UNIT

INLET DUCTWORK REQUIRES A MINIMUM OF TWO DUCT DIAMETERS STRAIGHT

RUN PRIOR TO UNIT CONNECTION. PROVIDE 12"X12" ACCESS DOOR IN STRAIGHT

DUCTWORK JUST DOWNSTREAM OF HOT WATER COIL FOR CLEANING.

COORDINATE EXACT BOX LOCATION WITH STRUCTURE, DUCTWORK, LIGHTING,

FIRE SPRINKLER, AND HYDRONIC PIPING. CONTROL PANEL CLEARANCES SHALL

BE MAINTAINED.

2 EXISTING TERMINAL UNIT.

3 BALANCE EXISTING TO REMAIN AIR DEVICE TO INDICATED AIRFLOW.

4 NEW DUCTWORK TO TIE INTO EXISTING AT THIS LOCATION.

5 ROUTE NEW DUCTWORK AS SHOWN. PROVIDE ELBOWS, OFFSETS, AND

TRANSITIONS AS NECESSSARY TO ACCOMMODATE EXISTING SYSTEMS.

(TYPICAL).

6 EXISTING TO REMAIN DUCTWORK. REINSULATE AS REQUIRED.

7 NEW DUCTWORK TO TIE INTO EXISTING SMOKE DAMPER AT THIS LOCATION.

PROVIDE TRANSITIONS AS NECESSARY.

8 PROVIDE NEW FIRE/SMOKE DAMPER AT EXISTING PENETRATION IN ELECTRICAL

ROOM WALL. PATCH AND REPAIR WALL TO MAINTAIN RATING.

9 ISOLATION EXHAUST VALVE OPERATION CONTROLLED BY ROOM PRESSURE

SENSORS AND ISOLATION CONTROLLER, REFERENCE DETAIL #1/M5.1.

10 FIRE/SMOKE DAMPER TO BE INSTALLED AT THIS LOCATION. SIZE DAMPER FOR

DIMENSIONS OF DUCTWORK AS NOTED. MAINTAIN REQUIRED ACCESS, PROVIDE

DUCT ACCESS DOOR. (TYP.)

11 ROOM PRESSURE MONITOR/CONTROLS TO BE INSTALLED FOR ISOLATION

ROOM. (TYP.) RE: CONTROLS.

(THIS SHEET ONLY)KEYED NOTES

N

SCALE: 1/4" = 1'-0"

TYPICAL FLOOR SECTION

VAV4K-2

VAV4K-4

VAV4K-7

VAV4K-10

VAV4K-14 VAV4K-15VAV4K-12

VAV4K-9

VAV4K-6

VAV4K-20

R1

S2

S2 85 S1

S2

S4

S2

E1

E1

E1

R1

R1

R1

R1

R1

R1

R1

R1

R1

R1

R1

R1

R1

R1

R1

R1

R1

S1

S2

S1

S2

S2

S1

S3

S2

S1

S2

S2

S2

S2

S2

S2

S1

S2

S2

S2

S2

S3

S2

S2

S3

S3

S3

S3

S3

S2

S2

S2

S1

S1

S2

S1

S1

S1

S1

S3

S3

S3

S3

S4

S4

S3

E1

E1

E1

R1

E3

E1

E1

E1

E1

E1

E1

E1 90 E1

S3

S3

S3

ER2

ER2

ES1

ES1

ER2

ER2

ES1

ES1

ES1

ER2

ES1

VAV4J-23VAV4J-49

ES1

ER1

ER1

ES1

ER1

VAV4K-46

ER1

295 VAV4K-44

ES1

ER2

ES1

ER2

VAV4K-17

VAV4K-18

VAV4K-16

VAV4K-13

"x

20"x14"

14"x14"24"x16"28"x20"30"x20"

"x

"x

"x

"x

22"x14"

"x

"x

16"x10"

18"x14"

"x

12"x14"

"x

14"x12"

"x

12"x6"

VAV4K-8

VAV4K-5

"x

24"x16" 24"x16"

VAV4J-22

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

1 1 1

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

"x

"ø

"ø

12"x10"

"x

"x

10"x8"

8"ø

8"ø

12"x14"

12"x14"

"ø

"ø

"ø

8"ø

"ø

8"x6"

8"x6"

"x

10"x12"

"ø

12"x12"

8"ø

8"ø 12"x14"

6"x6"

"x

6"x8"

"x

"ø

6"x6"

"x

12"x12"

8"ø

10"x12"

6"ø

6"x6"

8"ø

6"x6"8"ø 8"ø

"ø

"ø

12"x12"

"ø

"ø

"ø

"ø

8"ø

10"x10"

"ø

"x

6"x6"

12"ø 14"x12"

"ø

"ø

"ø

8"ø

"ø

"x

"x

"ø

"x

14"x12"

"x

12"x10"

"x

"x

6"ø

10"ø

10"x8"

"x

"x

"ø

"x

10"ø

"ø

"ø

"ø

"ø

6"ø

"x

6"x6"

6"x8"8"x8"

10"ø

6"ø

"x

"x

"x

6"ø

10"ø

"x

6"x8"

"x

ITU4K-3

ITU4K-4

"x

ITU4K-2

"x

E3

E3

VAV4K-3

12"ø

E3

E3 ø12"

E3

"x

E3

E3

E3

"x

"x

12"ø

E3

E3

10"x12"

(TYP)

12"ø

"ø

"x

14"x10"

"x

(TYP)

"x

(TYP)

WY U R P N M H G FJ.5L E D C BK J

STAIRS

TEAM WORK/

CLASS ROOM

4K53

NOURISHMENT

4K56

CLEAN UTILITY

4K39

EQUIPMENT

4K40

STORAGE ROOM

4K04

PATIENT TOILET

4K46B

PATIENT ROOM

(ISOLATION)

4K38

PATIENT ROOM

(ISOLATION)

4K37

PATIENT ROOM

(ISOLATION)

4K36

ANTE ROOM

4K38A

ANTE ROOM

4K37A

ANTE ROOM

4K36A

WORK ROOM

4K50

STORAGE

4K49

STAFF SUPPORT

ROOM

4K51

TOILET

4K51B

STAFF SUPPORT

ROOM

4J13

MEDICATION

PREP.

4K55

PATIENT ROOM

4K03

PATIENT TOILET

4K03B

PATIENT TOILET

4K02B

PATIENT ROOM

4K02

PATIENT ROOM

4K48

PATIENT TOILET

4K48B

PATIENT ROOM

4K47

PATIENT ROOM

4K44

PATIENT ROOM

4K43

SOILED UTILITY

4K41

PATIENT ROOM

4K42

PATIENT ROOM

4K46

WHL. CHR. STOR.

4K54

CONFERENCE

ROOM

4K01

PATIENT TOILET

4K42B PATIENT TOILET

4K43B

PATIENT TOILET

4K44B

PATIENT TOILET

4K36B

PATIENT TOILET

4K37B

PATIENT TOILET

4K38B

PATIENT TOILET

4K47B

"ø

"ø

10"x8"

6"ø

"ø

S2

S2

R1

PATIENT TOILET

4K45B

TL. COM. ROOM

4J12

TL. COM. ROOM

4K52

NURSE STATION

4K57

CLEAN LIN.

4K58

PATIENT ROOM

4K45

VAV4K-22

8"x12"

8"x8"

S2

"x

8"ø

VAV4J-24

VAV4K-23

S5

S5

8"x8"

"x

"x

VAV4K-11 TYP.

"x

6"ø

10"x10" 12"x12"

10"ø

R2

R2

6"ø

S2

12"x8"

"x

10"x8"

6"x6"

"ø

"ø

8"ø

R1 35 1

"x

" 10"x8"

10"x8"

8"ø

10"ø

"x

R1

"x

"x

T

T

T

T

T

T

T

T

T

T

T T

T

TTTT

T

"x

10"x8"

14"x10"

"x

"x

"x

"ø

10"ø

14"x14"

"ø

12"x10"

S3

10"ø

"ø

"x

R1

T

(TYP)

VAV4K-19

"ø

"ø

10"ø

12"x10"

"x

12"x10"

(TYP)

10"x8"

"x

10 10

TVAV4J-9

VAV4K-3

VAV4K-5

VAV4K-4

VAV4K-6

VAV4K-7

V A

V K

-1

VAV4K-8

VAV4K-9

VAV4K-23

VAV4K-11

VAV4K-20

VAV4K-13 VAV4K-16

VAV4K-17

VAV4K-18

VAV4K-15VAV4K-14

VAV4K-12

TVAV4K-19

P R

O J E

C T

7700 Torino St, Suite 101

San Antonio, TX 78229 Telephone: 210.614.1110

© 2020 Alderson & Associates, Inc.

F-1008

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Central Texas Veterans Health

Care System

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

PROJECT MANAGEMENT STAMPCONSULTANT

321 4 5 6 7 8 9 10

FULLY SPRINKLERED

CONSTRUCTION BID

DOCUMENTS

B

IM

/1

-1

T e m p le

V A

C o n v e rt

P a ti e n t R o o m s B ld g

/1

T e m p le

V A

B

M .r v t

/1

/2

:0

:2

A

M

M1.2

FOURTH FLOOR MECHANICAL FLOOR

PLAN - SOUTH

CONVERT BUILDING 204

PATIENT ROOMS TO

PRIVATE ROOMS

1901 VETERANS MEMORIAL DRIVE TEMPLE,

TX. 76504

10/13/20 MTK RMP

674-18-103

SCALE: 1/8" = 1'-0"

FOURTH FLOOR MECHANICAL FLOOR PLAN - SOUTH

1 MAINTAIN REQUIRED CLEARANCES ON ALL

TERMINAL UNITS. TERMINAL UNIT INLET DUCTWORK

REQUIRES A MINIMUM OF TWO DUCT DIAMETERS

STRAIGHT RUN PRIOR TO UNIT CONNECTION.

PROVIDE 12"X12" ACCESS DOOR IN STRAIGHT

DUCTWORK JUST DOWNSTREAM OF HOT WATER

COIL FOR CLEANING. COORDINATE EXACT BOX

LOCATION WITH STRUCTURE, DUCTWORK, LIGHTING,

FIRE SPRINKLER, AND HYDRONIC PIPING. CONTROL

PANEL CLEARANCES SHALL BE MAINTAINED.

2 EXISTING TERMINAL UNIT.

3 BALANCE EXISTING TO REMAIN AIR DEVICE TO

INDICATED AIRFLOW.

4 NEW DUCTWORK TO TIE INTO EXISTING AT THIS

LOCATION.

5 EXISTING TO REMAIN DUCTWORK. REINSULATE AS

REQUIRED.

6 ROUTE NEW DUCTWORK AS SHOWN. PROVIDE

ELBOWS, OFFSETS, AND TRANSITIONS AS

NECESSSARY TO ACCOMMODATE EXISTING

SYSTEMS. (TYPICAL).

7 EXISTING ISOLATION EXHAUST DUCTWORK TO

204-EF7G ON ROOF. REBALANCE LAB FAN FOR

TOTAL AIRFLOW FROM CONNECTED EXHAUST AIR

TERMINAL UNITS.

8 ISOLATION EXHAUST VALVE OPERATION

CONTROLLED BY ROOM PRESSURE SENSORS AND

ISOLATION CONTROLLER, REFERENCE DETAIL

#1/M5.1.

9 ROOM PRESSURE MONITOR/CONTROLS TO BE

INSTALLED FOR ISOLATION ROOM. (TYP.) RE:

CONTROLS.

10 FIRE/SMOKE DAMPER TO BE INSTALLED AT THIS

LOCATION. SIZE DAMPER FOR DIMENSIONS OF

DUCTWORK AS NOTED. MAINTAIN REQUIRED

ACCESS, PROVIDE DUCT ACCESS DOOR. (TYP.)

11 CONNECT NEW TERMINAL UNIT TO EXISTING

TEMPERATURE SENSOR CONTROLS LOCATED IN

DAYROOM.

N

Revisions: Date:

(THIS SHEET ONLY)KEYED NOTES

O J E

C T

7700 Torino St, Suite 101

San Antonio, TX 78229 Telephone: 210.614.1110

© 2020 Alderson & Associates, Inc.

F-1008

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Central Texas Veterans Health

Care System

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

PROJECT MANAGEMENT STAMPCONSULTANT

321 4 5 6 7 8 9 10

FULLY SPRINKLERED

CONSTRUCTION BID

DOCUMENTS

B

IM

/1

-1

T e m p le

V A

C o n v e rt

P a ti e n t R o o m s B ld g

/1

T e m p le

V A

B

M .r v t

/8

/2

:4 :3

P

M

M1.3

ENLARGED MECHANICAL ROOM AND

ROOF NEW WORK PLANS

CONVERT BUILDING 204

PATIENT ROOMS TO

PRIVATE ROOMS

1901 VETERANS MEMORIAL DRIVE TEMPLE,

TX. 76504

10/09/20 MTK RMP

674-18-103

Revisions: Date:

A

D

A

D

A

D

A

D

SFD

SFD

SFD

FD

FD

SFDSFD

SFD

F D

MPS

MPS

M P

S

MPS

P.E. Reg. No.

Engineer:

for permit, biddi

Document incom

INTERIM R

Dea

Firm:

Alderson

SCALE: 1/4" = 1'-0"

FOURTH FLOOR MECHANICAL ROOM ENLARGED NEW WORK PLAN

SCALE: 1/4" = 1'-0"

FIFTH FLOOR MECHANICAL ROOM ENLARGED NEW WORK PLAN

SCALE: 1/4" = 1'-0"

SIXTH FLOOR MECHANICAL ROOM ENLARGED NEW WORK PLAN

SCALE: 1/4" = 1'-0"

ROOF ENLARGED MECHANICAL NEW WORK PLAN

NO SCALE

ISOLATION EXHAUST RISER DIAGRAM

VAV4J-18

VAV4J-19

VAV4J-17

VAV4J-15

VAV4J-13

VAV4J-10

VAV4J-20

VAV4J-11

VAV4J-46

VAV4J-47

VAV4J-23

VAV4J-9

VAV4J-8 VAV4J-6

VAV4J-3

VAV4J-2

VAV4J-1

VAV4K-1

VAV4K-2

VAV4K-4

VAV4K-5

VAV4J-49

VAV4J-22

2-1/2"Ø HWS

2-1/2"Ø HWR

1-1/4"Ø HWR

/4

"Ø H

W S

/4

"Ø H

W R

2"Ø HWS

3/4"Ø HWS

3/4"Ø HWR

2"Ø HWS

2-1/2"Ø HWR

1-1/4"Ø HWR

2"Ø HWS2"Ø HWS

3/4"Ø HWS 3/4"Ø HWR

1-1/4"Ø HWR

2-1/2"Ø HWR

3/4"Ø HWS

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWR

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWR

3/4"Ø HWS

2"Ø HWS

1-1/2"Ø HWR

3/4"Ø HWS

3/4"Ø HWR

3/4"Ø HWR

3/4"Ø HWS

"Ø

H W

S

"Ø

H W

R

"Ø

H W

S

3/4"Ø HWS

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWR

"Ø

H W

R

3/4"Ø HWS

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWR

"Ø

H W

R

"Ø

H W

R

"Ø

H W

S

3/4"Ø HWS

3/4"Ø HWR

1"Ø HWR

1"Ø HWS 1-1/2"Ø HWS

-1

/2 "Ø

H W

S

-1

/2 "Ø

H W

R

2"Ø HWR

3/4"Ø HWS

3/4"Ø HWR

-1

/2 "Ø

H W

R -1

/2 "Ø

H W

R -1

/2 "Ø

H W

R

2"Ø HWR

2"Ø HWR

2"Ø HWR

2-1/2"Ø HWR

2-1/2"Ø HWR

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWS

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWR

-1

/2 "Ø

H W

S -1

/4 "Ø

H W

S -1

/4 "Ø

H W

S -1

/4 "Ø

H W

S "Ø

H W

S "Ø

H W

S

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWS

3/4"Ø HWR

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWS

3/4"Ø HWR

"Ø

H W

S "Ø

H W

S

"Ø

H W

R

(TYP)

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWR

3/4"Ø HWS

1-1/4"Ø HWS

"Ø

H W

R

3/4"Ø HWR

3/4"Ø HWS

1-1/2"Ø HWR

1-1/4"Ø HWS

1-1/2"Ø HWR

(TYP)

(TYP)

WY U R P N M H G FJ.5L EK J

STAIRS

PATIENT TOILET

4J22B

CLEAN UTILITY

4J29

STORAGE ROOM

4K04

ANTE ROOM

4J30A

ANTE ROOM

4J31A

PATIENT ROOM

(ISOLATION)

4J31

ANTE ROOM

4J32A

PATIENT ROOM

(ISOLATION)

4J32

ANTE ROOM

4J33A

PATIENT ROOM

(ISOLATION)

4J33

PATIENT ROOM

(ISOLATION)

4K37

PATIENT ROOM

(ISOLATION)

4K36

PATIENT ROOM

(ISOLATION)

4K35

MECHANICAL

4K34

ELECTRICAL

4K06

H.A.C.

4K05

STORAGE ROOM

4J07

ANTE ROOM

4K37A

ANTE ROOM

4K36A

ANTE ROOM

4K35A

CONFERENCE

4J19

NOURISHMENT

4J16

REPORT ROOM

4J11

STAFF SUPPORT

ROOM

4J13

MEDICATION

PREP.

4J15

EQUIPMENT

4J28

SOILED UTILITY

4J27

PATIENT TOILET

4J09B

PATIENT TOILET

4J08B

PATIENT ROOM

4J08

PATIENT ROOM

4J09

PATIENT ROOM

4K03

PATIENT TOILET

4K03B

PATIENT TOILET

4J20B

PATIENT TOILET

4J21B

PATIENT ROOM

4J22

PATIENT ROOM

4J24

PATIENT ROOM

4J25

PATIENT ROOM

4J26

PATIENT ROOM

(ISOLATION)

4J30

PATIENT ROOM

4J20

PATIENT ROOM

4J21

CONFERENCE

ROOM

4J10

PATIENT TOILET

4J24B

PATIENT TOILET

4J25B

PATIENT TOILET

4J26B

PATIENT TOILET

4J31B

PATIENT TOILET

4J32B

PATIENT TOILET

4K36B

PATIENT TOILET

4K35B

PATIENT TOILET

4J33B

PATIENT TOILET

4J30B

VAV4J-16

VAV4J-14

VAV4J-12

VAV4J-7

VAV4J-5 VAV4J-4

(TYP)

TL. COM. ROOM

4J12

PATIENT ROOM

4J23

PATIENT TOILET

4J23B

CLEAN LIN.

4J18

NURSE STATION

4J17

VAV4K-3

VAV4J-21

VAV4K-19

P R

O J E

C T

7700 Torino St, Suite 101

San Antonio, TX 78229 Telephone: 210.614.1110

© 2020 Alderson & Associates, Inc.

F-1008

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Central Texas Veterans Health

Care System

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

PROJECT MANAGEMENT STAMPCONSULTANT

321 4 5 6 7 8 9 10

FULLY SPRINKLERED

CONSTRUCTION BID

DOCUMENTS

B

IM

/1

-1

T e m p le

V A

C o n v e rt

P a ti e n t R o o m s B ld g

/1

T e m p le

V A

B

M .r v t

/1

/2

:0

:3

A

M

M2.1

FOURTH FLOOR MECHANICAL PIPING

FLOOR PLAN - NORTH

CONVERT BUILDING 204

PATIENT ROOMS TO

PRIVATE ROOMS

1901 VETERANS MEMORIAL DRIVE TEMPLE,

TX. 76504

10/13/20 MTK RMP

674-18-103

SCALE: 1/8" = 1'-0"

FOURTH FLOOR MECHANICAL PIPING FLOOR PLAN - NORTH

1 TIE EXISTING HOT WATER PIPING INTO NEW AT THIS LOCATION.

2 EXISTING TERMINAL UNIT.

3 TIE NEW HOT WATER PIPING INTO EXISTING AT THIS LOCATION.

4 TERMINAL UNITS TO RECEIVE TWO WAY CONTROL VALVES. CONTROL VALVE

SHALL BE INSTALLED IN AN ACCESSIBLE LOCATION, NO MORE THAN 24" ABOVE

CEILING, ON THE SAME SIDE OF THER TERMINAL UNIT AS THE CONTROL PANEL.

(TYPICAL).

5 HOT WATER PIPING EXISTING TO REMAIN.

6 NEW HOT WATER PIPING ROUTED ABOVE CEILING. PROVIDE NECESSARY

OFFSETS TO ACCOMMODATE OTHER UTILITES AND SYSTEMS. PIPING SHALL BE

ROUTED AS HIGH AS POSSIBLE AND SHALL NOT INTERFERE WITH REQUIRED

CLEARANCES OF TERMINAL UNIT. (TYPICAL).

7 PROVIDE INLINE ISOLATION VALVE AT THIS LOCATION. PROVIDE ACCESS TO

VALVES AS REQUIRED.

(THIS SHEET ONLY)KEYED NOTES

VAV4J-23

VAV4K-2

VAV4K-4

VAV4K-5

VAV4K-7

VAV4K-6

VAV4K-10VAV4K-8

VAV4K-9

VAV4K-20

VAV4K-12

VAV4K-13

VAV4K-16

VAV4K-14 VAV4K-15

VAV4K-18

VAV4K-17

VAV4K-44

VAV4K-46

VAV4J-49

VAV4J-221

"Ø

H W

S

3/4"Ø HWS

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWR

"Ø

H W

R

3/4"Ø HWS

3/4"Ø HWR

"Ø

H W

R

(TYP)

(TYP)

(TYP)

3/4"Ø HWS

3/4"Ø HWR

"Ø

H W

S

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWR

3/4"Ø HWS

1-1/4"Ø HWS

"Ø

H W

R "Ø

H W

R "Ø

H W

R "Ø

H W

R -1

/2 "Ø

H W

R

2-1/2"Ø HWR

2-1/2"Ø HWS

3/4"Ø HWR

3/4"Ø HWS

1"Ø HWR

3/4"Ø HWR

3/4"Ø HWS

-1

/2 "Ø

H W

S

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWR

3/4"Ø HWS

"Ø

H W

S -1

/2 "Ø

H W

S

1-1/2"Ø HWR

1-1/4"Ø HWS

1-1/2"Ø HWR

1-1/4"Ø HWS

1-1/2"Ø HWR

1-1/4"Ø HWR

1-1/2"Ø HWS

3/4"Ø HWS

3/4"Ø HWR

3/4"Ø HWR

3/4"Ø HWS

1"Ø HWR

1"Ø HWS

-1

/4 "Ø

H W

R "Ø

H W

R

3/4"Ø HWS

3/4"Ø HWR

"Ø

H W

R

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWS

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWR

3/4"Ø HWS

3/4"Ø HWR

1-1/2"Ø HWS

1-1/2"Ø HWR

1-1/4"Ø HWS 1-1/4"Ø HWS 1"Ø HWS

1"Ø HWR 1-1/4"Ø HWR 1-1/2"Ø HWR

1-1/4"Ø HWR

1-1/4"Ø HWR

1-1/2"Ø HWR1"Ø HWS

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

(TYP)

WY U R P N M H G FJ.5L E D C BK J

STAIRS

TEAM WORK/

CLASS ROOM

4K53

NOURISHMENT

4K56

CLEAN UTILITY

4K39 EQUIPMENT

4K40

STORAGE ROOM

4K04

PATIENT TOILET

4K46B

PATIENT ROOM

(ISOLATION)

4K38

PATIENT ROOM

(ISOLATION)

4K37

PATIENT ROOM

(ISOLATION)

4K36

ANTE ROOM

4K38A

ANTE ROOM

4K37A

ANTE ROOM

4K36A

WORK ROOM

4K50

STORAGE

4K49

STAFF SUPPORT

ROOM

4K51

TOILET

4K51B

MEDICATION

PREP.

4K55

PATIENT ROOM

4K03

PATIENT TOILET

4K03B

PATIENT TOILET

4K02B

PATIENT ROOM

4K02

PATIENT ROOM

4K48

PATIENT TOILET

4K48B

PATIENT ROOM

4K47

PATIENT ROOM

4K44

PATIENT ROOM

4K43

SOILED UTILITY

4K41

PATIENT ROOM

4K42

PATIENT ROOM

4K46

WHL. CHR. STOR.

4K54

CONFERENCE

ROOM

4K01

PATIENT TOILET

4K42B

PATIENT TOILET

4K43B

PATIENT TOILET

4K44B

PATIENT TOILET

4K36B

PATIENT TOILET

4K37B

PATIENT TOILET

4K38B

PATIENT TOILET

4K35B

PATIENT TOILET

4K47B

TL. COM. ROOM

4J12

PATIENT ROOM

4K45

PATIENT TOILET

4K45BNURSE STATION

4K57

CLEAN LIN.

4K58

TL. COM. ROOM

4K52

VAV4K-3

VAV4K-11

VAV4K-22

1"Ø HWR

1"Ø HWS

VAV4K-19

P R

O J E

C T

7700 Torino St, Suite 101

San Antonio, TX 78229 Telephone: 210.614.1110

© 2020 Alderson & Associates, Inc.

F-1008

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Central Texas Veterans Health

Care System

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

PROJECT MANAGEMENT STAMPCONSULTANT

321 4 5 6 7 8 9 10

FULLY SPRINKLERED

CONSTRUCTION BID

DOCUMENTS

B

IM

/1

-1

T e m p le

V A

C o n v e rt

P a ti e n t R o o m s B ld g

/1

T e m p le

V A

B

M .r v t

/1

/2

:0

:2

A

M

M2.2

FOURTH FLOOR MECHANICAL PIPING

FLOOR PLAN - SOUTH

CONVERT BUILDING 204

PATIENT ROOMS TO

PRIVATE ROOMS

1901 VETERANS MEMORIAL DRIVE TEMPLE,

TX. 76504

10/13/20 MTK RMP

674-18-103

SCALE: 1/8" = 1'-0"

FOURTH FLOOR MECHANICAL PIPING FLOOR PLAN - SOUTH

1 EXISTING TERMINAL UNIT.

2 TIE EXISTING HOT WATER PIPING INTO NEW AT THIS

LOCATION.

3 HOT WATER PIPING EXISTING TO REMAIN.

4 EXISTING HOT WATER PIPING FROM 4TH FLOOR

SOUTH MECHANICAL ROOM.

5 TERMINAL UNITS TO RECEIVE TWO WAY CONTROL

VALVES. CONTROL VALVE SHALL BE INSTALLED IN

AN ACCESSIBLE LOCATION, NO MORE THAN 24"

ABOVE CEILING, ON THE SAME SIDE OF THER

TERMINAL UNIT AS THE CONTROL PANEL.

(TYPICAL).

6 TIE NEW HOT WATER PIPING INTO EXISTING AT THIS

LOCATION.

7 NEW HOT WATER PIPING ROUTED ABOVE CEILING.

PROVIDE NECESSARY OFFSETS TO ACCOMMODATE

OTHER UTILITES AND SYSTEMS. PIPING SHALL BE

ROUTED AS HIGH AS POSSIBLE AND SHALL NOT

INTERFERE WITH REQUIRED CLEARANCES OF

TERMINAL UNIT. (TYPICAL).

8 PROVIDE INLINE ISOLATION VALVE AT THIS

LOCATION. PROVIDE ACCESS TO VALVES AS

REQUIRED.

N

Revisions: Date:

(THIS SHEET ONLY)KEYED NOTES

O J E

C T

7700 Torino St, Suite 101

San Antonio, TX 78229 Telephone: 210.614.1110

© 2020 Alderson & Associates, Inc.

F-1008

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Central Texas Veterans Health

Care System

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

PROJECT MANAGEMENT STAMPCONSULTANT

321 4 5 6 7 8 9 10

FULLY SPRINKLERED

CONSTRUCTION BID

DOCUMENTS

B

IM

/1

-1

T e m p le

V A

C o n v e rt

P a ti e n t R o o m s B ld g

/1

T e m p le

V A

B

M .r v t

/8

/2

:4 :4

P

M

M3.1

MECHANICAL SCHEDULES CONVERT BUILDING 204

PATIENT ROOMS TO

PRIVATE ROOMS

1901 VETERANS MEMORIAL DRIVE TEMPLE,

TX. 76504

10/09/20 MTK RMP

674-18-103

Revisions: Date:

P.E. Reg. No.

Engineer:

for permit, bidding or

Dean Alde

Firm:

Alderson & Ass

O J E

C T

7700 Torino St, Suite 101

San Antonio, TX 78229 Telephone: 210.614.1110

© 2020 Alderson & Associates, Inc.

F-1008

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Central Texas Veterans Health

Care System

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

PROJECT MANAGEMENT STAMPCONSULTANT

321 4 5 6 7 8 9 10

FULLY SPRINKLERED

CONSTRUCTION BID

DOCUMENTS

B

IM

/1

-1

T e m p le

V A

C o n v e rt

P a ti e n t R o o m s B ld g

/1

T e m p le

V A

B

M .r v t

/8

/2

:4 :4

P

M

M3.2

MECHANICAL SCHEDULES CONVERT BUILDING 204

PATIENT ROOMS TO

PRIVATE ROOMS

1901 VETERANS MEMORIAL DRIVE TEMPLE,

TX. 76504

10/09/20 Checker Author

O J E

C T

7700 Torino St, Suite 101

San Antonio, TX 78229 Telephone: 210.614.1110

© 2020 Alderson & Associates, Inc.

F-1008

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Central Texas Veterans Health

Care System

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

PROJECT MANAGEMENT STAMPCONSULTANT

321 4 5 6 7 8 9 10

FULLY SPRINKLERED

CONSTRUCTION BID

DOCUMENTS

B

IM

/1

-1

T e m p le

V A

C o n v e rt

P a ti e n t R o o m s B ld g

/1

T e m p le

V A

B

M .r v t

/8

/2

:4 :4

P

M

M4.1

MECHANICAL DETAILS CONVERT BUILDING 204

PATIENT ROOMS TO

PRIVATE ROOMS

1901 VETERANS MEMORIAL DRIVE TEMPLE,

TX. 76504

10/09/20 MTK RMP

674-18-103

Revisions: Date:

P.E. Reg. No.

Engineer:

for permit, bidding or construction.

Document incomplete: Not intended

INTERIM REVIEW ONLY

Dean Alderson

54441

Firm:

Alderson & Associates, F-1008

F

L

E

X

I

B

L

E

C

O

N

N

E

C

T

I

O

N

D

I

R

E

C

T

I

F

A

I

O

W

D

U

A

N

S

I

T

I

O

N

S

R

U

C

T

U

A

B

O

V

E

H

A

N

G

C

U

R

E

D

I

N

L

I

N

T

R

I

F

U

G

N

V

I

B

R

A

T

I

O

L

A

T

O

R

S

A

Z

E

X

U

D

U

N

G

T

H

D

U

Q

U

I

R

E

D

C

O

N

N

E

C

T

I

O

N

F

E

R

F

L

E

X

I

B

C

T

M

I

N

I

M

S

S

I

B

L

E

A

O

W

B

R

A

N

C

H

C

O

N

I

C

E

L

E

N

G

H

R

A

I

G

H

T

S

H

O

W

A

N

R

E

D

U

C

E

R

E

I

N

S

U

L

A

T

M

I

N

R

U

C

T

U

B

O

V

E

R

O

U

V

A

L

S

U

P

P

Y

N

G

C

U

R

E

D

1. PROVIDE 4"x6" INTERNALLY INSULATED 1" STAND OFF ACCESS DOOR IN 12 INCH COIL ACCESS

R

E

Q

U

I

R

E

D

I

N

L

D

U

C

ON THE SAME SIDE OF THE TERMINAL BOX.

2. CONTROLLER ENCLOSURE, CONNECTIONS AND CONTROL VALVE ASSEMBLY SHALL BE

SECTION.

F

R

T

L

Z

E

T

R

A

N

S

I

T

I

Q

U

I

R

C

L

O

S

U

R

E

T

A

M

R

H

T

I

F

E

R

C

O

P

I

G

N

N

E

C

T

I

O

N

S

NOTES:

C

T

D

U

S

U

L

A

T

I

A

L

L

T

E

R

M

I

N

I

T

S

E

C

T

I

A

L

C

O

V

T

I

L

C

O

N

T

R

O

L

L

E

R

N

O

3. 1-1/2 NOZZLE DIAMETERS STRAIGHT DUCT.

NOTES:

1. LATCHES SHALL BE OF THE WEDGE TYPE TO CLOSE DOORS TIGHTLY.

2. HINGES ON THE ACCESS DOORS SHALL HAVE NON-CORROSIVE PINS.

3. ACCESS DOOR SHALL NOT PROTRUDE INTO AIRSTREAM.

"A"

"A"

SECTION "A - A"

DUCT

GASKET

DUCT

EXTERNAL

INSULATION

ACCESS PANEL

ACCESS DOOR

SECTION "B - B"

HANDLE INSIDE

GASKET

CASING

FLEXIBLE

WASHER

DUCT EXTERNAL

INSULATION

FACTORY FABRICATED LATCH

ROD CONTINUOUS ON 2"

W.G. CLASS AND ON ALL

DAMPERS OVER 12" DIA.

WINGNUT

CONTROL

ARM

TWO BLADE ARRANGEMENT

ROUND DAMPER

BEARING OPTION

OUTSIDE END

16GA. BLADE

1/8" CLEARANCE ALL

AROUND 19" TO 48"

1/8" CLEARANCE ALL

AROUND UP TO 18"

1/2" ROD-PIN

DUCT

3/8" PIN

22GA. BLADE

1/2"

D U

P

T H

STIFFEN AS REQ'D.

SIDE ELEVATION

DUCT SECTION

DUCT SECTION

BEARING

INSIDE END

BEARING

NOTE: OVER 12" HIGH

USE 2 BLADE ARRANGEMENT

END BEARING REQ'D.

END BEARING

REQUIRED.

3/8"

QUADRANT

1/2"

QUADRANT

FLAT OVAL INSULATED DUCT WITH BOTTOM BEARER

STRIP

SHEET METAL

BEARER

SHEET METAL

STRIP

SHEET METAL

WITH SPLIT CLIP BRACKET

CIRCULAR INSULATED DUCT

STRIP

RECTANGULAR DUCT

CIRCULAR INSULATED DUCT

INSULATION

WITH STIRRUP BRAKET

RECTANGULAR DUCT

INSULATION

X

I

M

N

G

T

H

NO SCALE

NO SCALE NO SCALE NO SCALE

NO SCALE

SIDE VIEW

TRAPEZE HANGER FOR UP

TO 1000 LB. UNIFORM LOAD

ADJUSTABLE CLEVIS HANGER

TYPE 1 IN SPECIFICATIONS

INSULATION

PROVIDE HIGH COMPRESSIVE

STRENGTH INSULATION INSERT

UNDER INSULATION SHIELD

INSULATION SHIELD

AT HANGER

HANGER ROD

1/2" DIA. HANGER RODS

WITH 36" MAX. SPACING

ON EACH CHANNEL

PROVIDE INSULATION

SHIELD & INSERT FOR

ALL PIPING

1-5/8" 12 GAGE

CHANNEL OR

2" x 2" x 1/4" ANGLE

STAINLESS ZIP

NO SCALE

APPLICABLE ONLY TO SINGLE DUCT TERMINAL UNIT REHEAT COILS, 2 PIPE

PIPE COIL FOR COUNTERFLOW OF WATER WITH RESPECT TO AIRFLOW

3.

OR 4 PIPE FAN COIL UNITS.

2.

WHEN COIL HAS TWO OR MORE ROWS.

NOTES:

AIRVENT

AIRFLOW

SUPPLY

RETURN

A STRAIGHT - THRU MODULATING CONTROL VALVE IS SHOWN.1.

DRAIN

NO SCALE

PROVIDE DAMPER HANDLE EXTENSIONS TO

NOTE:

ACCOMMODATE INSULATION THICKNESS.

SQUARE 90°

W

1.

SHALL ONLY BE USED FOR 90°

ELBOWS. FOR ANGLES OTHER THAN

90° USE RADIUS ELBOW CONSTRUCTION.

NOTES:

2. PARTIAL ELBOWS, ALL SIZES SHALL

BE CONSTRUCTED AS RADIUS ELBOWS.

1�" 1�"

MIN. 26 GA.

VANES

2�"

1" R

2" R

45°

45°

TURNING VANE DETAIL

A

R=1.5A

DIE STAMPED

90° ELBOW

DIE STAMPED

45° ELBOW

A

R=1.5A

RADIUS ELBOWS UP TO 8"

FABRICATED

5 GORE

90° ELBOW

A

R=1.5A

RADIUS ELBOWS OVER 8"

0-35° 2 PIECES

36-71° 3 PIECES

72-90° 5 PIECES

NO SCALE NO SCALE NO SCALE

1 2 3 4

5 6

NOTE-1

12 x 16

16 x 16

1212 x 12

1210 x 12

1210 x 10

128 x 12

108 x 10

88 x 8

86 x 8

FLEX. DIA.

ALTERNATE FLAT OVAL (H x W)H x W

DUCT SIZE

2. SUPPLY AIR DIFFUSER SHOWN, RETURN AIR SIMILAR.

MAXIMUM FLEX LENGTH 36" OR 3 DUCT DIAMETERS

NOTES:

MAXIMUM FLEX LENGTH 36" OR 3 DUCT DIAMETERS

1. MINIMUM UNCOMPRESSED FLEX LENGTH 24"

NOTE-1

NOTE-1

NOTE-1

NOTE-1

TYPE 5

TYPE 4

TYPE 3

TYPE 2

TYPE 1

DIA

8 x 11 7 x 12 6 x 12

10 x 13 8 x 15 7 x 17

10 x 13 8 x 15 7 x 17

10 x 13 8 x 15 7 x 17

10 x 13 8 x 15 7 x 17

14 x 17 12 x 18 10 x 19

14 x 17 12 x 18 10 x 19

NO SCALE

TIE BAND

O J E

C T

7700 Torino St, Suite 101

San Antonio, TX 78229 Telephone: 210.614.1110

© 2020 Alderson & Associates, Inc.

F-1008

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Central Texas Veterans Health

Care System

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

PROJECT MANAGEMENT STAMPCONSULTANT

321 4 5 6 7 8 9 10

FULLY SPRINKLERED

CONSTRUCTION BID

DOCUMENTS

B

IM

/1

-1

T e m p le

V A

C o n v e rt

P a ti e n t R o o m s B ld g

/1

T e m p le

V A

B

M .r v t

/8

/2

:4 :4

P

M

M4.2

MECHANICAL DETAILS CONVERT BUILDING 204

PATIENT ROOMS TO

PRIVATE ROOMS

1901 VETERANS MEMORIAL DRIVE TEMPLE,

TX. 76504

10/09/20 MTK RMP

674-18-103

Revisions: Date:

P.E. Reg. No.

Engineer:

for permit, bidding or construc

Document incomplete: Not int

INTERIM REVIEW ON

Dean Alderson

54441

Firm:

Alderson & Associates, RADIUS ELBOW 90°

NOTES:

1. ALL ELBOWS WITH W < 12" SHALL BE

RADIUS ELBOWS.

2. W < 32 INCHES R=W

W > 32 INCHES R= 1/2W

W > 32 INCHES R= 1/2W

W < 32 INCHES R=W2.

BE CONSTRUCTED AS RADIUS ELBOWS.

PARTIAL ELBOWS, ALL SIZES SHALL1.

NOTES:

RADIUS ELBOWS 30/45/60°

W

R

W

R

*MIN. 2.5 DUCT DIA.

* A MINIMUM OF 2.5 DUCT DIAMETERS OF STRAIGHT RUN (I.E.; VOID OF

REDUCERS, FITTINGS, VALVES OR OTHER APPURTENANCES) SHALL BE

PROVIDED UPSTREAM (INLET SIDE) OF THE CONTROL VALVE. DUCT

DIAMETER SHALL BE IDENTICAL TO THE DIAMETER OF THE VALVE FOR A

MINIMUM OF 2.5 DUCT DIAMETERS UPSTREAM (INLET SIDE) OF THE

CONTROL VALVE.

CONNECTION TO

ROOM EXHAUST

AIR DEVICE (TYP).

FINISHED CEILING

CEILING PLENUM

EXHAUST CONTROL

VALVE (ECV)

EXHAUST MAIN

AIR FLOW

NO SCALE NO SCALE

1 2

CONCRETE

ANGLE. ALL PIPES

4" MIN DEPTH

EXISTING CONSTRUCTION AND

INSERTS FOR NEW CONSTRICTION

IN SLABS OR BEAMS OF

3/8" MIN DIA INSERTS

NEW CONSTRUCTION ONLY.

TURNBUCKLE

3/8" MIN DIA

HANGER RODS

ANGLE

CLIP

FLOOR SLAB

3/8" MIN DIA

HANGER RODS

NUTS & WASHERS

FOR PIPES UNDER 2"

IN SIZE USE 1 1/2"x1 1/2"x1/4"

2" AND LARGER USE

3"x3"x1/4" ANGLE

3/8" MIN DIA EXPANSION BOLTS

FOR EXISTING CONSTRUCTION AND

INSERTS FOR NEW CONSTRUCTION

THIS TYPE SHALL BE USED ONLY

STEEL EXPANSION SHIELD FOR

NO SCALE

NO SCALE

NO SCALE

NO SCALE

NO SCALE

NO SCALE

O J E

C T

7700 Torino St, Suite 101

San Antonio, TX 78229 Telephone: 210.614.1110

© 2020 Alderson & Associates, Inc.

F-1008

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Central Texas Veterans Health

Care System

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

PROJECT MANAGEMENT STAMPCONSULTANT

321 4 5 6 7 8 9 10

FULLY SPRINKLERED

CONSTRUCTION BID

DOCUMENTS

B

IM

/1

-1

T e m p le

V A

C o n v e rt

P a ti e n t R o o m s B ld g

/1

T e m p le

V A

B

M .r v t

/8

/2

:4 :4

P

M

M5.1

MECHANICAL CONTROLS CONVERT BUILDING 204

PATIENT ROOMS TO

PRIVATE ROOMS

1901 VETERANS MEMORIAL DRIVE TEMPLE,

TX. 76504

10/09/20 MTK RMP

Sheets
M0.0 - MECHANICAL SYMBOLS & ABBREVIATIONS
MD1.1 - FOURTH FLOOR MECHANICAL DEMOLITION PLAN - NORTH
MD1.2 - FOURTH FLOOR MECHANICAL DEMOLITION PLAN - SOUTH
MD1.3 - ENLARGED MECHANICAL ROOM DEMOLITION PLAN
MD2.1 - FOURTH FLOOR MECHANICAL PIPING DEMOLITION PLAN - NORTH
MD2.2 - FOURTH FLOOR MECHANICAL PIPING DEMOLITION PLAN - SOUTH
M1.1 - FOURTH FLOOR MECHANICAL FLOOR PLAN - NORTH
M1.2 - FOURTH FLOOR MECHANICAL FLOOR PLAN - SOUTH
M1.3 - ENLARGED MECHANICAL ROOM AND ROOF NEW WORK PLANS
M2.1 - FOURTH FLOOR MECHANICAL PIPING FLOOR PLAN - NORTH
M2.2 - FOURTH FLOOR MECHANICAL PIPING FLOOR PLAN - SOUTH
M3.1 - MECHANICAL SCHEDULES
M3.2 - MECHANICAL SCHEDULES
M4.1 - MECHANICAL DETAILS
M4.2 - MECHANICAL DETAILS
M5.1 - MECHANICAL CONTROLS

File details come from the government source that posted it. Updated .