About this file

This federal contract opportunity solicitation is for construction services to convert patient rooms to private rooms at building 204 of the Olin E. Teague Veterans Medical Center in Temple, Texas. The solicitation includes details such as the project magnitude being between $1,000,000 to $2,000,000, it being a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses, the NAICS code of 238210 with a small business size standard of $16.5M, and contact information for questions. Apparent successful offerors must apply for and receive verification from the VA Center for Verification and Evaluation by the time of proposal submission.

View the file

Other files

File Type Posted
36C25722B0028 0003.docx DOCX document
Project Walk Through Sign In Sheet.pdf PDF
Bid Schedule B - project 674-18-103 Add Alternate.pdf PDF
36C25722B0028 0002.docx DOCX document
36C25722B0028 0001.docx DOCX document
TEMPLE_CONVERT_BLDG204_PATIENT_RMS_TECH-PLANS Model 08-20-2020.pdf PDF
2020-1_3.pdf PDF
2020-1_1.pdf PDF
100 percent Sealed ARCH SPECS TEMPLE CONVERT 204 VOL 2.pdf PDF
100 percent Sealed ARCH SPECS TEMPLE CONVERT 204 VOL 1.pdf PDF
2020-1_2.pdf PDF
36C25722B0028_1.docx DOCX document
Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OLIN E. TEAGUE VETERANS MEDICAL CENTER

1901 VETERANS MEMORIAL DRIVE

TEMPLE, TX. 76504

CONVERT BUILDING 204 PATIENT ROOMS TO PRIVATE ROOMS

PROJECT # 674-18-103

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Central Texas Veterans Health

Care System

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhasePROJECT MANAGEMENT STAMPARCHITECT

321 4 5 6 7 8 9 10

10/13/2020

INTERIORSARCHITECTURE

COX DESIGN ASSOCIATES

PLANNING

Austin Chicago Denver El Paso

Austin, Texas 78746 5121 Bee Caves Road, Suite 203

BI

M

VA

T

EM

PL

E

C O

N

VE

R T

PA

TI

EN

T

R O

O M

S/

.2 0.

T

EM

PL

E_

C O

N

VE

R T_

BL

D

G

4_

PA

TI

EN

T_ R

M S.

rv t

/2

2/

:3 2:

P

M

GI-000

100% CONSTRUCTION

DOCUMENTS

COVER SHEET CONVERT BUILDING 204

PATIENT ROOMS TO

PRIVATE ROOMS

1901 VETERANS MEMORIAL DRIVE

TEMPLE, TX. 76504

12/22/2020 RHC RJP

674-18-103

BUILDING IS

FULLY

SPRINKLED

ARCHITECTURE MEPPROJECT MANAGEMENT

7700 Torino St, Suite 101 San Antonio, TX 78229

Telephone: 210.614.1110 ©2018 Alderson & Associates, Inc.

F-1008

Revisions: Date:

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Central Texas Veterans Health

Care System

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhasePROJECT MANAGEMENT STAMPARCHITECT

321 4 5 6 7 8 9 10

10/13/2020

INTERIORSARCHITECTURE

COX DESIGN ASSOCIATES

PLANNING

Austin Chicago Denver El Paso

Austin, Texas 78746 5121 Bee Caves Road, Suite 203

BI

M

VA

T

EM

PL

E

C O

N

VE

R T

PA

TI

EN

T

R O

O M

S/

.2 0.

T

EM

PL

E_

C O

N

VE

R T_

BL

D

G

4_

PA

TI

EN

T_ R

M S.

rv t

/2

2/

:2 1:

P

M

GI-001

100% CONSTRUCTION

DOCUMENTS

INDEX OF SHEETS CONVERT BUILDING 204

PATIENT ROOMS TO

PRIVATE ROOMS

1901 VETERANS MEMORIAL DRIVE

TEMPLE, TX. 76504

12/22/2020 RHC RJP

674-18-103

BUILDING IS

FULLY

SPRINKLED

TECHNOLOGY

T001 TECHNOLOGY - COVER PAGE

T002 TECHNOLOGY- MATRIX

T100 TECHNOLOGY - 4TH FLOOR NORTH DEMOLITION PLAN

T101 TECHNOLOGY - 4TH FLOOR NORTH DEMOLITION REFLECTED CEILING PLAN

T102 TECHNOLOGY - 4TH FLOOR SOUTH DEMOLITION PLAN

T103 TECHNOLOGY - 4TH FLOOR SOUTH DEMOLITION REFLECTED CEILING PLAN

T200 TECHNOLOGY - 4TH FLOOR NORTH TECHNOLOGY PLAN

T201 TECHNOLOGY - 4TH FLOOR SOUTH TECHNOLOGY PLAN

T300 TECHNOLOGY - 4TH FLOOR NORTH PATHWAY LAYOUT

T301 TECHNOLOGY - 4TH FLOOR SOUTH PATHWAY LAYOUT

T400 TECHNOLOGY - TELECOM ROOM LAYOUT

T401 TECHNOLOGY - TELECOM ROOM - RACK ELEVATION

T500 TECHNOLOGY - 4TH FLOOR NORTH TECHNOLOGY REFLECTED CEILING PLAN

T501 TECHNOLOGY - 4TH FLOOR SOUTH TECHNOLOGY REFLECTED CEILING PLAN

T600 TECHNOLOGY - RISER DIAGRAM

T700 TECHNOLOGY - TYPICAL DETAILS

T701 TECHNOLOGY - TYPICAL DETAILS

T702 TECHNOLOGY - TYPICAL DETAILS

T703 TECHNOLOGY - TYPICAL DETAILS

SECURITY

TS100 TECHNOLOGY - 4th FLOOR NORTH SECURITY DEMOLITION PLAN TS101 TECHNOLOGY- 4th FLOOR SOUTH SECURITY DEMOLITION PLAN

TS200 TECHNOLOGY- 4TH FLOOR NORTH SECURITY PLAN

TS201 TECHNOLOGY- 4th FLOOR SOUTH SECURITY PLAN

TS700 TECHNOLOGY - SECURITY TYPICAL DETAILS

ARCHITECTURAL

AI-100 4TH FLOOR - LIFE SAFETY PLAN

AD-104 4TH FLOOR - DEMOLITION PLAN

AD-104.1 4TH FLOOR - DEMOLITION PLAN - SOUTH

AD-104.2 4TH FLOOR - DEMOLITION PLAN - NORTH

AS-104 4TH FLOOR - FLOOR PLAN

AS-104.1 4TH FLOOR - FLOOR PLAN - SOUTH

AS-104.2 4TH FLOOR - FLOOR PLAN - NORTH

AS-105 ROOF PLAN NORTH

AS-111 4TH FLOOR - DIMENSION PLAN

AS-111.1 4TH FLOOR - DIMENSION PLAN - SOUTH

AS-111.2 4TH FLOOR - DIMENSION PLAN - NORTH

AS-121 4TH FLOOR - FLOOR FINISH PLAN

AS-121.1 4TH FLOOR - FLOOR FINISH PLAN - SOUTH

AS-121.2 4TH FLOOR - FLOOR FINISH PLAN - NORTH

AS-131 4TH FLOOR - REFLECTED CEILING PLAN

AS-131.1 4TH FLOOR - REFLECTED CEILING PLAN - SOUTH

AS-131.2 4TH FLOOR - REFLECTED CEILING PLAN - NORTH

AS-301 BUILDING SECTIONS

AS-302 BUILDING SECTIONS

AS-310 WALL SECTIONS

AS-401 ENLARGED FLOOR PLANS

AS-402 ENLARGED FLOOR PLANS

AS-403 ENLARGED FLOOR PLANS

AS-404 ENLARGED FLOOR PLANS

AS-410 INTERIOR ELEVATIONS

AS-411 INTERIOR ELEVATIONS

AS-412 INTERIOR ELEVATIONS

AS-413 INTERIOR ELEVATIONS

AS-414 INTERIOR ELEVATIONS

AS-415 INTERIOR ELEVATIONS

AS-416 INTERIOR ELEVATIONS

AS-506 CASEWORK DETAILS

AS-507 CEILING DETAILS

AS-508 FLOOR FINISH DETAILS

AS-520 WALL TYPES

AS-536 ARCHITECTURAL DETAILS

AS-610 DOOR & WINDOW SCHEDULE / DOOR & WINDOW TYPES

AS-620 DOOR DETAILS

AS-630 ROOM FINISH/MATERIAL FINISH SCHEDULES

ELECTRICAL

ES-000 ELECTRICAL SYMBOLS & ABBREVIATIONS

ESD-101 4TH FLOOR - ELECTRICAL DEMOLITION - NORTH PLAN

ESD-102 4TH FLOOR - ELECTRICAL DEMOLITION - SOUTH PLAN

ES-101 4TH FLOOR - LIGHTING PLAN - NORTH PLAN

ES-102 4TH FLOOR - LIGHTING PLAN - SOUTH PLAN

ES-201 4TH FLOOR - POWER PLAN - NORTH PLAN

ES-202 4TH FLOOR - POWER PLAN - SOUTH PLAN

ES-203 4TH FLOOR - PARTIAL FLOOR PLANS

ES-204 4TH FLOOR - MECH./PLUMB. POWER PLAN - NORTH PLAN

ES-205 4TH FLOOR - MECH./PLUMB. POWER PLAN - SOUTH PLAN

ES-301 4TH FLOOR - SPECIAL SYSTEMS PLAN - NORTH PLAN

ES-302 4TH FLOOR - SPECIAL SYSTEMS PLAN - SOUTH PLAN

ES-303 4TH FLOOR - FIRE ALARM PLAN - NORTH PLAN

ES-304 4TH FLOOR - FIRE ALARM PLAN - SOUTH PLAN

ES-401 RISER DIAGRAM - ESSENTIAL DISTRIBUTION

ES-402 RISER DIAGRAM - NORMAL DISTRIBUTION

ES-501 ELECTRICAL SCHEDULES

ES-502 ELECTRICAL SCHEDULES

ES-503 ELECTRICAL SCHEDULES

ES-504 ELECTRICAL SCHEDULES

ES-505 ELECTRICAL SCHEDULES

ES-601 ELECTRICAL DETAILS

ES-602 ELECTRICAL DETAILS

MECHANICAL

M0.0 MECHANICAL SYMBOLS & ABBREVIATIONS

MD1.1 FOURTH FLOOR MECHANICAL DEMOLITION PLAN - NORTH

MD1.2 FOURTH FLOOR MECHANICAL DEMOLITION PLAN - SOUTH

MD1.3 ENLARGED MECHANICAL ROOM DEMOLITION PLAN

MD2.1 FOURTH FLOOR MECHANICAL PIPING DEMOLITION PLAN - NORTH

MD2.2 FOURTH FLOOR MECHANICAL PIPING DEMOLITION PLAN - SOUTH

M1.1 FOURTH FLOOR MECHANICAL FLOOR PLAN - NORTH

M1.2 FOURTH FLOOR MECHANICAL FLOOR PLAN - SOUTH

M1.3 ENLARGED MECHANICAL ROOM and ROOF NEW WORK PLANS

M2.1 FOURTH FLOOR MECHANICAL PIPING FLOOR PLAN - NORTH

M2.2 FOURTH FLOOR MECHANICAL PIPING FLOOR PLAN - SOUTH

M3.1 MECHANICAL SCHEDULES

M3.2 MECHANICAL SCHEDULES

M4.1 MECHANICAL DETAILS

M4.2 MECHANICAL DETAILS

M5.1 MECHANICAL CONTROLS

PLUMBING

P0.0 PLUMBING SYMBOLS AND ABBREVIATIONS

PD1.1 LEVEL 4 OVERALL PLUMBING DEMOLITION PLAN

PD1.2A LEVEL 4 PLUMBING DEMOLITION PLAN - NORTH

PD1.2B LEVEL 4 PLUMBING DEMOLITION PLAN - SOUTH

P1.1 LEVEL 4 OVERALL PLUMBING NEW WORK PLAN

P1.2 LEVEL 4 PLUMBING NEW WORK PLAN - NORTH

P1.3 LEVEL 4 PLUMBING NEW WORK PLAN - SOUTH

P1.4 LEVEL 3 OVERALL PLUMBING NEW WORK PLAN - CEILING SPACE

P1.5 LEVEL 3 PLUMBING NEW WORK PLAN - CEILING SPACE - NORTH

P1.6 LEVEL 3 PLUMBING NEW WORK PLAN - CEILING SPACE - SOUTH

P2.1 LEVEL 4 PLUMBING ENLARGEMENTS - NORTH A

P2.1A LEVEL 4 PLUMBING ISOMETRIC - NORTH A

P2.1B LEVEL 4 MED GAS ISOMETRIC - NORTH A

P2.2 LEVEL 4 PLUMBING ENLARGEMENTS - NORTH B

P2.2A LEVEL 4 PLUMBING ISOMETRIC - NORTH B

P2.2B LEVEL 4 MED GAS ISOMETRIC - NORTH B

P2.3 LEVEL 4 PLUMBING ENLARGEMENTS - SOUTH A

P2.3A LEVEL 4 PLUMBING ISOMETRIC - SOUTH A

P2.3B LEVEL 4 MED GAS ISOMETRIC -SOUTH A

P2.4 LEVEL 4 PLUMBING ENLARGEMENTS - SOUTH B

P2.4A LEVEL 4 PLUMBING ISOMETRIC - SOUTH B

P2.4B LEVEL 4 MED GAS ISOMETRIC -SOUTH B

P3.1 PLUMBING SCHEDULES

P4.1 PLUMBING DETAILS

P4.2 PLUMBING DETAILS

FIRE PROTECTION

FP1.1A FOURTH FLOOR FIRE PROTECTION NEW WORK PLAN - NORTH

FP1.1B FOURTH FLOOR FIRE PROTECTION NEW WORK PLAN - SOUTH

GENERAL

GI-000 COVER SHEET

GI-001 INDEX OF SHEETS

GI-002 GENERAL NOTES

GI-003 ARCHITECTURAL ABBREVIATIONS

GI-004 ACCESSIBILITY STANDARDS

GI-005 ACCESSIBILITY STANDARDS

GI-006 ACCESSIBILITY STANDARDS

INDEX OF DRAWINGS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Central Texas Veterans Health

Care System

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhasePROJECT MANAGEMENT STAMPARCHITECT

321 4 5 6 7 8 9 10

10/13/2020

INTERIORSARCHITECTURE

COX DESIGN ASSOCIATES

PLANNING

Austin Chicago Denver El Paso

Austin, Texas 78746 5121 Bee Caves Road, Suite 203

BI

M

VA

T

EM

PL

E

C O

N

VE

R T

PA

TI

EN

T

R O

O M

S/

.2 0.

T

EM

PL

E_

C O

N

VE

R T_

BL

D

G

4_

PA

TI

EN

T_ R

M S.

rv t

/2

2/

:2 1:

P

M

GI-002

100% CONSTRUCTION

DOCUMENTS

GENERAL NOTES CONVERT BUILDING 204

PATIENT ROOMS TO

PRIVATE ROOMS

1901 VETERANS MEMORIAL DRIVE

TEMPLE, TX. 76504

12/22/2020 RHC RJP

674-18-103

BUILDING IS

FULLY

SPRINKLED

DRAWINGS FOR THE FOLLOWING DISCIPLINES ARE

CONTAINED IN THE DOCUMENT. THE DISCIPLINES ARE

IDENTIFIED BY THE REFERENCE WHICH IS

INCORPORATED INTO THE SHEET TITLE.

EACH DRAWING IS NUMBERED ACCORDING TO IT'S

LOCATION ON THE SHEET. THE DRAWING TITLE

APPEARS ABOVE THE DEMARCATION LINE AND, APPROPRIATE THE

SCALE IS LOCATED BELOW THE DEMARCATION LINE IN THE LOWER

LEFT-HAND QUADRANT OF THE KEY. THE DRAWING CAN BE

REFERENCED BACK TO IT'S ORIGINAL SHEET AND

DRAWING BY THE DRAWING REFERENCE LOCATION IN

THE LOWER RIGHT-HAND QUADRANT.

SHEET NUMBER

DRAWING NUMBER ON SHEET BY LOCATION

REFERENCE

DISCIPLINE REFERENCES

DRAWING NUMBERING

DRAWING REFERENCE

REF. 1/1-A1

BUILDING SECTION

RE: 1/AS-126

SHEET NUMBER

ARCHITECTURAL FLOOR PLAN SYMBOLS

A

COLUMN GRID

NORTH ARROW

REVISION NUMBER AND EXTENT

KEYED NOTE MARK

-SEE CORRESPONDING

NUMBERED KEY NOTE ON SHEET WHERE

REFERENCE OCCURS

REVISION NUMBER - SEE

REVISION HISTORY ON THE

TITLE BLOCK OF EACH SHEET

EXTENT OF CURRENT REVISION

1-A26

1-A26

CL

DEMOLITION LINE

ELEVATION INDICATOR

CENTER LINE INDICATOR

EXISTING TO REMAIN LINE

FEATURES ABOVE LINE INDICATOR

BREAK, ROUND (USER DEFINES SIZE)

BREAK, STRAIGHT (SEE SECTION INDICATORS,

BUILDING, WITH BREAK STANDARDS)

DETAIL INDICATOR

DETAIL INDICATOR

DIMENSION LINE

CENTER LINE

GI GENERAL INFORMATION

A ARCHITECTURAL

FP FIRE PROTECTION

P PLUMBING

M MECHANICAL

E ELECTRICAL

T TECHNOLOGY

AS-100

DISCIPLINE SHEET NUMBER

CONSTRUCTION LIMITS

N

EXISTING TO REMAIN

CONCRETE

MASONRY

BUILDING INTERIOR

MATERIAL GRAPHICS

GYP BD RIGID INSULATION

WOOD EARTH

S STRUCTURAL

EXCEPT WHERE DIRECTED TO PLACE ITEMS OF THE WORK AT THE

"APPROXIMATE LOCATION SHOWN." DO NOT SCALE DRAWINGS FOR

DIMENSIONAL INFORMATION

1.

ALL ELEMENTS OF THE DOCUMENTS MAY NOT BE DRAWN TO EXACT SCALE.

ALL DIMENSIONS REQUESTED ARE SHOWN (OR MAY BE DERIVED FROM THOSE

SHOWN OR NOTED) ON THE FLOOR PLANS. DETAIL PLANS, ELEVATIONS,

SECTIONS, SCHEDULES, CONFIGURATION DETAILS, AND SPECIFICATIONS. SEE

THE NOTES BELOW AND SYMBOLS FOR DIMENSIONING CONVENTIONS USED

ON THIS PROJECT.

2.

EXCEPT WHERE SPECIFICALLY NOTED TO THE CONTRARY, ALL DIMENSIONS

SHOWN ON THE ARCHITECTURAL DRAWINGS CONFORM TO THE FOLLOWING

CONVENTIONS.

3.

DIMENSIONS UTILIZING THE "CENTERLINE" SYMBOL ARE MEASURED TO:

· CENTERLINE OF PARTITION ASSEMBLY (EXCLUSIVE OF ANY APPLIED

FINISHES HAVING THICKNESS WHICH MAY BE ADDED TO SUCH

WALLS) AT PARTITIONS FRAMED WITH METAL STUDS. REFER TO

"PARTITION SCHEDULE" TO DETERMINE THICKNESS OF EACH

PARTITION TYPE.

· CENTERLINE OF DOOR, WINDOW, OR LOUVER OPENING.

· CENTERLINE OF OTHER FEATURES AS INDICATED.

A.

DIMENSIONS UTILIZING THE "FACE OF" SYMBOL ARE MEASURED TO:

· FACE OF PARTITION ASSEMBLY (EXCLUSIVE OF ANY APPLIED

FINISHES HAVING THICKNESS WHICH MAY BE ADDED TO SUCH WALL)

AS DEFINED BY THE PARTITION SCHEDULE. UNLESS NOTED AS A

"FACE OF FINISH" OR "CLEAR" DIMENSION (SEE NOTE "E" BELOW),

DIMENSIONS ARE NOT MEASURED TO THE FACE OF APPLIED FINISH.

REFER TO THE "PARTITION SCHEDULE" TO DETERMINE THE

THICKNESS OF EACH PARTITION TYPE.

B.

WHERE "EQUAL" DIMENSIONS ARE USED ON REFLECTED CEILING PLANS TO

LOCATE CEILING GRID WORK POINTS, MEASURE DIMENSIONS TO:

· EDGE OF THE INDICATED CEILING AT THE FACE OF THE ADJACENT

APPLIED FINISH MEASURED AT THE PLANE OF THE CEILING.

· CAUTION: DUE TO THE POSSIBLE APPLICATION OF APPLIED FINISHES -

THICKNESS OF WHICH MAY VARY BETWEEN FLOOR AND CEILING AND

IS NOT ACCOUNTED FOR (EXCEPT AS INDICATED BY "FOF" OR

"CLEAR") BY THE DIMENSION SHOWN ON THE FLOOR PLANS - THE

CONTRACTOR MUST ADJUST AS NECESSARY, THE FLOOR PLAN

DIMENSIONS TO REFLECT THE ACTUAL DIMENSIONS FOUND AT PLANE

OF THE CEILING.

C.

WHERE WALLS AND/OR PARTITIONS OF UNEQUAL THICKNESS ABUT,

ALIGN EXPOSED FACES, UNLESS OTHERWISE NOTED.

4.

ALIGN

DIMENSION, WHEN OCCURS

WHERE OPENINGS IN WALLS (SUCH AS INTERIOR WINDOWS OR DOORS) ARE

NOT DIMENSIONED BUT SHOWN AS BEING IN THE CENTER OF A GIVEN WALL

SURFACE, LOCATE OPENINGS AS GRAPHICALLY REPRESENTED.

5.

GENERAL NOTES - CONT. DIMENSIONING CONVENTIONS

DESIGN MANUALS:

- PG-18-1 MASTER CONSTRUCTION SPECIFICATIONS

- PG-18-3 DESIGN AND CONSTRUCTION PROCEDURES

- PG-18-5 EQUIPMENT LIST GUIDES

- PG-18-8 SEISMIC DESIGN HANDBOOK

- PG-18-10 DESIGN MANUALS

- VA PHYSICAL SECURITY DESIGN MANUAL FOR MISSION CRITICAL FACILITIES

- VA DESIGN GUIDELINES FOR ELEVATORS

- VA ARCHITECTURAL DESIGN MANUAL

- VA MECHANICAL DESIGN MANUAL

- VA ELECTRICAL DESIGN MANUAL

- VA PLUMBING DESIGN MANUAL

- VA FIRE PROTECTION DESIGN MANUAL

APPLICABLE CODES AND REGULATIONS:

ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL CURRENT APPLICABLE CODES AND STANDARDS.

IN ADDITION TO ALL DEPARTMENT OF VETERANS AFFAIRS, LOCAL, AND STATE CODES, ALL WORK SHALL COMPLY WITH THE ACCESSIBILITY REQUIREMENTS OF THE STATE OF TEXAS AND THE DEPARTMENT OF VETERANS AFFAIRS GUIDELINES, ABA (ARCHITECTURAL BARRIERS ACT) ACCESSIBILITY STANDARD FOR FEDERAL FACILITIES.

APPLICABLE CODES AND STANDARDS (LATEST EDITIONS) INCLUDE:

- ABA ACCESSIBILITY STANDARDS

- NFPA 101, "LIFE SAFETY CODE"

- NFPA 10, "PORTABLE FIRE EXTINGUISHERS"

- NFPA 13, "INSTALLATION OF SPRINKLER SYSTEMS"

- NFPA 70, "NATIONAL ELECTRICAL CODE (NEC)"

- NFPA 72, "NATIONAL FIRE ALARM CODE"

- NFPA 90A, "INSTALLATION OF AIR CONDITIONING AND VENTILATION SYSTEMS"

- NFPA 99, "INSTALLATION FOR HEALTH CARE FACILITIES"

- NFPA 220, "TYPES OF BUILDING CONSTRUCTION"

- NFPA 241, "STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS"

- INTERNATIONAL BUILDING CODE (IBC)

- INTERNATIONAL MECHANICAL CODE (IMC)

- INTERNATIONAL PLUMBING CODE (IPC)

- INTERNATIONAL ENERGY CONSERVATION CODE

PROJECT SUMMARY

GENERAL NOTES

THE GENERAL CONTRACTOR SHALL VISIT THE SITE, VERIFY FIELD CONDITIONS

AND CAREFULLY COMPARE SUCH FIELD CONDITIONS AND OTHER INFORMATION

KNOWN TO THE CONTRACTOR WITH CONTRACT DOCUMENTS.

UNLESS NOTED TO BE REMOVED AND DISPOSED, ALL EXISTING ITEMS ARE TO

REMAIN. THEY SHALL BE PROTECTED FROM DAMAGE DUE TO CONSTRUCTION

ACTIVITIES. ANY EXISTING ITEMS TO REMAIN THAT BECOME DAMAGED DUE TO

CONSTRUCTION ACTIVITIES SHALL BE REPAIRED OR REPLACED TO MATCH

EXISTING AT NO ADDITIONAL COST TO THE OWNER..

NOTATIONS FOR ITEMS OF WORK APPLY TO EACH AND EVERY GRAPHICAL

INDICATION SHOWN ON THE DRAWINGS, WHETHER OR NOT NOTED.

ALL ITEMS NOTED TO HAVE PAINT FINISH SHALL BE THOROUGHLY CLEANED

AND PROPERLY PREPARED IN ACCORDANCE WITH THE SPECIFICATIONS PRIOR

TO THE APPLICATION OF PRIMER AND PAINT.

THE CONTRACTOR SHALL THOROUGHLY FAMILIARIZE HIMSELF WITH THE

MECHANICAL, ELECTRICAL, AND PLUMBING WORK AND SATISFY THE

REQUIREMENTS FOR SUPPORT, FLOOR, WALL AND ROOF OPENINGS,

FLASHINGS AND CURBS ETC. THE ARCHITECT SHALL BE NOTIFIED OF

CONFLICTS OR DISCREPANCIES PRIOR TO COMMENCEMENT OF

CONSTRUCTION.

CONTRACTOR TO REPLACE & ACCURATELY LOCATE ALL EXISTING SIGNAGE

AND LABELS NOTING RATED WALL ASSEMBLIES AND SMOKE PARTITIONS

THE GENERAL CONTRACTOR SHALL REPORT ANY UNFORESEEN FIELD

CONDITIONS, ERRORS, INCONSISTENCIES, OR OMISSIONS DISCOVERED AT ANY

TIME DURING THE WORK, UPON SUCH DISCOVERY, THE CONTRACTOR SHALL

IMMEDIATELY CONTACT THE CONTRACT OFFICER FOR CLARIFICATION BEFORE

PROCEEDING OR CONTINUING WITH THAT PORTION OF THE WORK OR ANY

PORTION RELATED THERE TO.

ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES AND STANDARDS

INCLUDING THE INTERNATIONAL BUILDING CODE 2018 EDITION AND CURRENT,

VA MASTER SPECIFICATIONS, AND NFPA 101 2018 EDITION AND CURRENT.

THE GENERAL CONTRACTOR SHALL NOTIFY THE CONTRACT OFFICER,

CONTRACTING OFFICER'S REPRESENTATIVE, AND ARCHITECT OF ANY

DISCREPANCIES BETWEEN THE DRAWINGS, NOTES AND ACTUAL FIELD

CONDITIONS BEFORE BIDDING AND COMMENCING ANY WORK, AND REQUEST

CLARIFICATION IN WRITING.

WHEN UNANTICIPATED MECHANICAL, ELECTRICAL, OR STRUCTURAL ELEMENTS

THAT CONFLICT WITH THE INTENDED FUNCTION OR DESIGN ARE

ENCOUNTERED, INVESTIGATE AND MEASURE THE NATURE AND EXTENT OF THE

CONFLICT. PROMPTLY SUBMIT A WRITTEN REPORT TO THE CONTRACT

OFFICER.

WHERE MOUNTING HEIGHTS ARE NOT INDICATED, INSTALL COMPONENTS

USING MANUFACTURER'S OR INDUSTRY STANDARDS. WHERE STANDARDS DO

NOT EXIST, NOTIFY THE ARCHITECT FOR CLARIFICATION.

CONTRACTOR SHALL NOT BARRICADE / BARRIER EMERGENCY EGRESS TO OR

FROM THIS AREA. CONTRACTOR SHALL MAINTAIN EXIT TO EXTERIOR DURING

THE WORK PROCESS

PROVIDE ACCESS TO THE WORK AS DIRECTED BY THE C.O.R. SECURE ACCESS

POINT AS SPECIFIED AND DIRECTED BY THE COR PROJECT ENGINEER.

PROVIDE WALK-OFF MATS TO MEET FACILITY INFECTION CONTROL GUIDELINES

AT EACH ACCESS POINT.

CONTRACTOR TO NOTIFY VA 2 WEEKS IN ADVANCE PRIOR TO ANY MAJOR

UTILITY DISRUPTIONS OR OUTAGES.

IN THE CASE OF CONFLICTS OR DISCREPANCIES WITHIN OR AMONG THE

CONTRACT DOCUMENTS, THE BETTER QUALITY, MORE STRINGENT

REQUIREMENTS OR GREATER QUANTITY OF WORK, AS DETERMINED BY THE

GOVERNMENT, SHALL BE PROVIDED.

LOCATION MAP - NTS

N

ARCHITECTURAL ABBREVIATIONS

A LABEL CLASS A DOOR

A/C AIR CONDITION

A/C UNIT AIR CONDITIONING UNIT

A/E ARCHITECT/ENGINEER

AAMA AMERICAN ARCHITECTURAL MANUFACTURERS

ASSOCIATION

AB ANCHOR BOLT

ABC AGGREGATE BASE COURSE

AC ASBESTOS CEMENT OR ASPHALTIC CONCRETE

ACI AMERICAN CONCRETE INSTITUTE

ACS DR ACCESS DOOR

ACS FLR ACCESS FLOOR

ACS PNL ACCESS PANEL

ACST ACOUSTIC

ACT ACOUSTICAL CEILING TILE

AD AREA DRAIN

ADA AMERICANS WITH DISABILITIES ACT

ADC AUTOMATIC DOOR CLOSER

ADDL ADDITIONAL

ADDN ADDITION

ADH ADHESIVE

ADJ ADJACENT, ADJOINING, OR ADJUSTABLE

ADMIN ADMINISTRATION

ADB AUTOMATIC DOOR BOTTOM

AFC ABOVE FINISHED COUNTER

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AFS ABOVE FINISHED SLAB

AGA AMERICAN GAS ASSOCIATION

AGC ASSOCIATED GENERAL CONTRACTORS

AGGR AGGREGATE

AHJ AUTHORITY HAVING JURISDICTION

AHR ANCHOR

AHU AIR HANDLING UNIT

AIA AMERICAN INSTITUTE OF ARCHITECTS

AISC AMERICAN INSTITUTE OF STEEL

CONSTRUCTION

ALT ALTERNATE

ALT NO ALTERNATE NUMBER

ALUM ALUMINUM

AMP AMPERE

AMT AMOUNT

ANOD ANODIZE

ANSI AMERICAN NATIONAL STANDARDS INSTITUTE

ANT ANTENNA

APA AMERICAN PLYWOOD ASSOCIATION

APPD APPROVED

APPROX APPROXIMATE

APT APARTMENT

AR AS REQUIRED

ARCH ARCHITECT

ASB ASBESTOS

ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTION

ASKLR AUTOMATIC SPRINKLER

ASPH ASPHALT

ASSN ASSOCIATION

ASTM AMERICAN SOCIETY FOR TESTING AND

MATERIALS

ATCH ATTACHMENT

ATM AUTOMATIC TELLER MACHINE

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AUX AUXILIARY

AV AUDIO VISUAL

AVE AVENUE

AVG AVERAGE

AW ACID WASTE

AWI ARCHITECTURAL WOODWORKING INSTITUTE

AWPA AMERICAN WOOD PRESERVERS' ASSOCIATION

AWS AMERICAN WELDING SOCIETY

AWT ACOUSTICAL WALL TREATMENT

B LABEL CLASS B DOOR

B PL BASE PLATE

BALC BALCONY

BAT BATTEN

BB BULLETIN BOARD

BD BOARD

BD FT BOARD FEET (FOOT)

BEV BEVEL

BHMA BUILDER'S HARDWARE MANUFACTURER'S

ASSOCIATION

BI FLD DR BIFOLDING DOORS

BITUM BITUMINOUS

BKG BACKING

BLD BUILD

BLDG BUILDING

BLKT BLANKET

BLVD BOULEVARD

BM BEAM OR BENCHMARK

BOT BOTTOM

BR BEDROOM

BRCG BRACING

BRDG BRIDGING

BRDG JST BRIDGING JOIST

BRG BEARING

BRG PL BEARING PLATE

BRKT BRACKET

BRZ BRONZE

BSMT BASEMENT

BTWN BETWEEN

BU BUSHEL

BUR BUILT-UP ROOFING

C CELSIUS CHANNEL

C CHANNEL CELSIUS

C CONC CAST CONCRETE

C LABEL CLASS C DOOR

C TO C CENTER TO CENTER

CAB CABINET

CAC CEILING ATTENUATION CLASS

CB CATCH BASIN OR CORNER BEAD

CBB CEMENTITIOUS (BACKER) BOARD

CC CUBIC CENTIMETER

CCTV CLOSED CIRCUIT TELEVISION

CCW COUNTERCLOCKWISE

CD CONSTRUCTION DOCUMENTS OR CONTRACT

DOCUMENTS

CEM CEMENT

CEM PLAS CEMENT PLASTER

CER CERAMIC

CF CONTRACTOR FURNISHED

CF/CI CONTRACTOR FURNISHED/CONTRACTOR

INSTALLED

CF/OI CONTRACTOR FURNISHED/OWNER INSTALLED

CFLG COUNTERFLASHING

CFM CUBIC FEET PER MINUTE

CFMF COLD-FORMED METAL FRAMING

CFS CUBIC FEET PER SECOND

CG CENTER OF GRAVITY OR CORNER GUARD

CGSFU CERAMIC GLAZED STRUCTURAL FACING UNITS

CH BD CHALKBOARD

CHEM CHEMICAL

CHFR CHAMFER

CHK CHECK

CI CAST IRON

CIP CAST-IN-PLACE

CIR CIRCLE

CIRC CIRCULAR

CJ CONSTRUCTION JOINT OR CONTROL JOINT

CL CENTER LINE

CLDG CLADDING

CLG CEILING

CLG HT CEILING HEIGHT

CLR CLEAR

cm² SQUARE CENTIMETER cm³ CUBIC CENTIMETER

CM CONSTRUCTION MANAGEMENT

CMU CONCRETE MASONRY UNIT

CNR CORNER

CNTR COUNTER

CO CARBON MONOXIDE, CERTIFICATE OF

OCCUPANCY, CLEANOUT, OR COMPANY

CO2 CARBON DIOXIDE

COL COLUMN

COM COMMON

COMB COMBINATION, COMBINED

COMM COMMUNICATION

COMP COMPONENT

CONC CONCRETE

CONC FLR CONCRETE FLOOR

COND CONDENSER OR CONDITION

CONF CONFERENCE

CONN CONNECT

CONSTR CONSTRUCTION

CONT CONTINUE

CONTR CONTRACTOR

COORD COORDINATE

CORR CORRIDOR

CPM CRITICAL PATH METHOD

CPRS COMPRESSIBLE

CPT CARPET

CRS COLD ROLLED STEEL

CRSI CONCRETE REINFORCING STEEL INSTITUTE

CSB CONCRETE SPLASH BLOCK

CSG CASING

CSI CONSTRUCTION SPECIFICATIONS INSTITUTE

CSK COUNTER SUNK

CSMT CASEMENT

CSWK CASEWORK

CT CERAMIC TILE

CTB CERAMIC TILE BASE

CTF CERAMIC TILE FLOOR

CTG COATING

CTR CENTER CONTOUR

CTRL CONTROL

CTV CABLE TELEVISION

CU COPPER C

CU FT CUBIC FEET

CU IN CUBIC INCH

CU YD CUBIC YARD

CURT CURTAIN

CYL CYLINDER

CYL L CYLINDER LOCK

D DEPTH OR PENNY (NAIL)

D LABEL CLASS D DOOR

DAT DATUM

DB DECIBEL

DBL DOUBLE

DBL GLZ DOUBLE GLAZE

DC DIRECT CURRENT

DEG DEGREE

DEL DELETE

DEMO DEMOLITION

DEPT DEPARTMENT

DET DETAIL

DF ELECTRIC WATER COOLER

DIA DIAMETER

DIAG DIAGONAL DIAGRAM

DIAG DIAGRAM DIAGONAL

DIFF DIFFERENCE OR DIFFUSER

DIM DIMENSION

DIR DIRECTION

DISP DISPENSER

DIST DISTANCE

DIV DIVIDE OR DIVISION

DL DEAD LOAD

DOC DOCUMENT

DOUG FIR DOUGLAS FIR

DOZ DOZEN

DR DOOR, DRAIN, DRESSING ROOM, OR DRIVE

DR CL DOOR CLOSER

DR FR DOOR FRAME

DR OPNG DOOR OPENING

DS DOWNSPOUT

DSGN DESIGN

DW DISHWASHER

DWG DRAWING

DWTR DUMBWAITER

E EAST

E LABEL CLASS E DOOR

EA EACH

EFF EFFICIENCY

EFS EXTERIOR FINISH SYSTEM

EIFS EXTERIOR INSULATION AND FINISH SYSTEM

EJ EXPANSION JOINT

EL ELEVATION

ELAST ELASTOMERIC

ELEC ELECTRIC

ELEC DR OP ELECTRIC DOOR OPENER

ELEV ELEVATOR

EMER EMERGENCY

EMER SHR EMERGENCY SHOWER

ENCL ENCLOSURE

ENGR ENGINEER

ENVIR ENVIRONMENT

EPA ENVIRONMENTAL PROTECTION AGENCY

EPDM ETHYLENE PROPYLENE DIENE MONOMER

EPO EMERGENCY POWER OFF

EPS EXPANDED POLYSTYRENE BOARD (INSULATION)

EQ EQUAL

EQL SP EQUALLY SPACED

EQUIP EQUIPMENT

EQUIV EQUIVALENT

ERD EXISTING ROOF DRAIN

ESC ESCAPE OR ESCUTCHEON

ESCAL ESCALATOR

ESMT EASEMENT

ESP ESPECIALLY

EST ESTIMATE

ETC AND SO FORTH OR ET CETERA

EW EACH WAY

EWC ELECTRIC WATER COOLER

EWS EYE WASH STATION

EXH EXHAUST

EXIST EXISTING

EXP EXPANSION OR EXPOSED

EXP BT EXPANSION BOLT

EXST GR EXISTING GRADE

EXT EXTERIOR, EXTERNAL, OR EXTINGUISHER

EXT GR EXTERIOR GRADE

F FAHRENHEIT OR FEMALE

FA FIRE ALARM

FAB FABRIC

FAC FACTOR

FACIL FACILITY

FAS FASCIA

FAS BD FASCIA BOARD

FCO FLOOR CLEANOUT

FCTY FACTORY

FD FLOOR DRAIN

FDC FIRE DEPARTMENT CONNECTION

FDTN FOUNDATION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FF FINISH FACE

FF EL FINISH FLOOR ELEVATION

FF&E FURNITURE, FIXTURE, AND EQUIPMENT

FH FLAT HEAD OR FLAT HEAD SCREWS

FHC FIRE HOSE CABINET

FHMS FLAT HEAD MACHINE SCREW

FHP FULL HEIGHT PARTITION

FHWS FLAT HEAD WOOD SCREW

FIG FIGURE

FIL FILLET

FIN FINISH

FIN FLR FINISH FLOOR

FIN GR FINISH GRADE

FIN WD FINISH WOOD

FIXT FIXTURE

FL FLOORLINE

FLASH FLASHING

FLDG FOLDING

FLEX FLEXIBLE

FLG FLOORING

FLR FLOOR

FLR FIN FLOOR FINISH

FLR SK FLOOR SINK

FLUOR FLUORESCENT

FLUOR FIX FLUORESCENT FIXTURE

FM FACTORY MUTUAL

FM-G FACTORY MUTUAL GLOBAL

FO FINISHED OPENING

FOC FACE OF CONCRETE OR FACE OF CURB

FOF FACE OF FINISH

FOM FACE OF MASONRY

FOS FACE OF SLAB OR FACE OF STUD

FOUNT FOUNTAIN

FOW FACE OF WALL

FP FIRE PROTECTION OR FIREPROOF

FPM FEET PER MINUTE

FPS FEET PER SECOND

FR FIRE RATING, FIRE RESISTANT, OR FRAME

FR SNK FLUSHING RIM SINK

FREQ FREQUENCY

FRMG FRAMING

FRP FIBER REINFORCED POLYESTER OR

FIBERGLASS REINFORCED PLASTIC

FRZ FREEZER

FS FEDERAL SPECIFICATION

FSTNR FASTENER

FT FEET OR FOOT

FTG FOOTING

FURG FURRING

FURN FURNISH OR FURNITURE

FUT FUTURE

FWC FABRIC WALLCOVERING

GA GAGE OR GYPSUM ASSOCIATION

GAL GALLON

GALV GALVANIC OR GALVANIZED

GALV STL GALVANIZED STEEL

GB GRAB BAR

GC GENERAL CONTRACTOR

GD GUARD

GDR GUARD RAIL

GEN GENERAL OR GENERATOR

GFRC GLASS-FIBER-REINFORCED CONCRETE

GFRG GLASS-FIBER-REINFORCED GYPSUM

GFRP GLASS-FIBER-REINFORCED PLASTIC

GI GALVANIZED IRON

GL GLASS

GL BLK GLASS BLOCK

GLU LAM GLUED LAMINATED WOOD

GR FL GROUND FLOOR

GRAN GRANITE

GRTG GRATING

GSB GYPSUM SHEATHING BOARD

GSM GALVANIZED SHEET METAL

GSU GLAZED STRUCTURAL UNIT

GT GROUT

GUAR GUARANTEE

GUT GUTTER

GYP GYPSUM

GYP BD GYPSUM BOARD

GYP PLAS GYPSUM PLASTER

H HIGH

H PLAM HIGH PRESSURE PLASTIC LAMINATE

HAZ MAT HAZARDOUS MATERIALS

HB HOSE BIBB

HC HOLLOW CORE

HCWD HOLLOW CORE WOOD DOOR

HDBD HARDBOARD

HDNR HARDENER

HDO HIGH DENSITY OVERLAY

HDR HEADER

HDW HARDWARE

HDWD HARDWOOD

HEPA HIGH EFFICIENCY PARTICULATE AIR (FILTER)

HEX HEXAGON

HF HIGH FREQUENCY

HGR HANGER

HM HECTOMETER

HM HOLLOW METAL

HMD HOLLOW METAL DOOR

HMDF HOLLOW METAL DOOR AND FRAME

HMF HOLLOW METAL FRAME

HNDRL HANDRAIL

HO HOLD OPEN

HORIZ HORIZONTAL

HOSP HOSPITAL

HP HIGH PRESSURE OR HORSEPOWER

HQ HEADQUARTERS

HS HEAT-STRENGTHENED (GLASS) OR HIGH

STRENGTH

HSE HOUSE

HSKPG HOUSEKEEPING

HST HOIST

HT HEIGHT

HVAC HEATING, VENTILATING, AND AIR CONDITIONING

HVY HEAVY

HW HOT WATER

HYD HYDRANT

HYDR HYDRAULIC

I INTERSTATE (HIGHWAY) OR MOMENT OF

INERTIA

IAQ INDOOR AIR QUALITY

IBC INTERNATIONAL BUILDING CODE

ID IDENTIFICATION, INSIDE DIAMETER, OR

INTERIOR DESIGN

ID NO IDENTIFICATION NUMBER

ILLUM ILLUMINATION

INCL INCLUDED

IND INDEPENDENT OR INDUSTRIAL

INFO INFORMATION

INSUL INSULATION

INT INTERIOR

INTERCOM INTERCOMMUNICATION

INTL INTERNATIONAL

IRMA INVERTED ROOF MEMBRANE ASSEMBLY

IWH INSTANTANEOUS WATER HEATER

JAN JANITOR

J-BOX JUNCTION BOX

KD KILN DRIED OR KNOCKED DOWN

KIT KITCHEN

KO KNOCKOUT

KPL KICKPLATE

L ANGLE

LAB LABORATORY

LAD LADDER

LAM LAMINATE

LAM GL LAMINATED GLASS

LAU LAUNDRY

LAV LAVATORY

LBR LUMBER

LBS POUND

LD BRG LOAD-BEARING

LDR LEADER

LED LIGHT EMITTING DIODE

LF LINEAR FEET (FOOT)

LH LEFT HAND

LHR LEFT HAND REVERSE

LHR LEFT HAND REVERSE LATENT HEAT RATIO

LIB LIBRARY

LIN LINEAR

LINO LINOLEUM

LIQ LIQUID

LKR LOCKER

LKR RM LOCKER ROOM

LKWASH LOCKWASHER

LL LEAD LINED

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LMST LIMESTONE

LNDSCP LANDSCAPE

LR LIVING ROOM

LRG LARGE

LRV LOUVERED ROOF VENT

LS LUMP SUM

LT LIGHT

LT GA LIGHT GAGE

LT WT LIGHTWEIGHT

LTG LIGHTING

LTNG LIGHTNING

LVD LOUVERED

LVR LOUVER

LWC LIGHTWEIGHT CONCRETE

LWIC LIGHTWEIGHT INSULATING CONCRETE

LYR LAYER

MACH MACHINE

MACH RM MACHINE ROOM

MAINT MAINTENANCE

MAN MANUAL

MATL MATERIAL

MATV MASTER ANTENNA TELEVISION SYSTEM

MAX MAXIMUM

MB MACHINE BOLT

MCB METAL CORNER BEAD

MD DECK

ME MECHANICAL ENGINEER

MEAS MEASURE

MECH MECHANICAL

MECH RM MECHANICAL ROOM

MED MEDICAL MEDIUM

MED MEDIUM MEDICAL

MEK METHYL ETHYL KETONE

MEL MELAMINE

MEMB MEMBRANE

MEMO MEMORANDUM

MEZZ MEZZANINE

MF MILL FINISH

MFD MANUFACTURED

MFG MANUFACTURING

MFR MANUFACTURER

MFR REC MANUFACTURER'S RECOMMENDATION

MGT MANAGEMENT

MH MANHOLE

MIC MICROPHONE

MID MIDDLE

MIL STD MILITARY STANDARD

MIN MINIMUM MINUTE

MIN MINUTE MINIMUM

MIRR MIRROR

MISC MISCELLANEOUS

MIT MITER

MKR MARKER

ML METAL LATH

MLDG MOLDING (MOULDING)

MLWK MILLWORK

mm MILLIMETER

MO MASONRY OPENING OR MOTOR OPERATED

MOD MODEL, MODIFY OR MODULE

MOD BIT MODIFIED BITUMEN

MON MONITOR

MOPR MOP RACK

MR MOISTURE RESISTANT

MS MACHINE SCREW OR MOP SINK

MTD MOUNTED

MTG MOUNTING

MTL METAL

MULL MULLION

MW MICROWAVE

MWP MEMBRANE WATERPROOFING

N NORTH

NA NOT APPLICABLE

NAAMM NATIONAL ASSOCIATION OF ARCHITECTURAL

METAL MANUFACTURERS

NAT NATURAL

NATL NATIONAL

NC NOISE CRITERIA

NCOMBL NONCOMBUSTIBLE

NEC NATIONAL ELECTRICAL CODE

NEG NEGATIVE

NEMA NATIONAL ELECTRICAL MANUFACTURERS

ASSOCIATION

NEUT NEUTRAL

NFC NATIONAL FIRE CODE

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NR NOISE REDUCTION

NRC NOISE REDUCTION COEFFICIENT

NRCA NATIONAL ROOFING CONTRACTORS

ASSOCIATION

NRP NONREMOVABLE

NS NARROW STILE

NUM NUMERAL

O/O OUT TO OUT

O OXYGEN

OA OUTSIDE AIR OR OVERALL

OC ON CENTER

OCC OCCUPY

OCT OCTAGON

OD OUTSIDE DIAMETER OUTSIDE DIMENSION

OD OUTSIDE DIMENSION OUTSIDE DIAMETER

OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED

OFD OVERFLOW DRAIN

OFF OFFICE

OF/OI OWNER FURNISHED/OWNER INSTALLED

OH OVERHANG

OH DR OVERHEAD (COILING) DOOR

OPH OPPOSITE HAND

OPNG OPENING

OPP OPPOSITE

OPR OPERABLE

OPT OPTIONAL

OR OPERATING ROOM OR OUTSIDE RADIUS

ORD ORDNANCE OR OVERFLOW ROOF DRAIN

ORG ORGANIC

ORIG ORIGINAL

ORN ORNAMENTAL

OSHA OCCUPATIONAL SAFETY AND HEALTH

ADMINSTRATION

OUT OUTLET

OZ OUNCE

PAR PARALLEL OR PARAPET

PARA PARAGRAPH

PART PARTIAL

PAT PATTERN

PB PUSHBUTTON

PBD PARTICLEBOARD

PC PIECE, POLYCARBONATE OR PORTLAND

CEMENT

PCA PORTLAND CEMENT ASSOCIATION

PCC PRECAST CONCRETE

PCCP CONCRETE PAVEMENT

PCD PAPER CUP DISPENSER

PCF POUNDS PER CUBIC FOOT

PCP PORTLAND CEMENT PLASTER

PED PEDESTAL

PEN PENETRATE

PEND PENDANT

PERF PERFORATED

PERIM PERIMETER

PERP PERPENDICULAR

PGBD PEGBOARD

PHAR PHARMACY

PHOTO PHOTOGRAPH

PHS PHILLIPS HEAD SCREW

PKG PACKAGE

PL PROPERTY LINE

PL GL PLATE GLASS

PLAM PLASTIC LAMINATE

PLAS PLASTER OR PLASTIC

PLBG PLUMBING

PLYWD PLYWOOD

PMTL PAINTED METAL

PNEU PNEUMATIC

PNL PANEL

PO POST OFFICE PURCHASE ORDER

PO PURCHASE ORDER POST OFFICE

POLY POLYETHYLENE (PLASTIC)

PR PAIR

PRCST PRECAST

PREFAB PREFABRICATE

PREFIN PREFINISH

PRELIM PRELIMINARY

PREP PREPARATION

PRESS PRESSURE

PREV PREVIOUS

PRKG PARKING

PRMLD PREMOLDED

PROJ PROJECT

PROP PROPERTY

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PAINT, PNEUMATIC TUBE, OR PRESSURE

TREATED

PTD PAPER TOWEL DISPENSER

PTN PARTITION

PVC POLYVINYL CHLORIDE (PLASTIC)

PVG PAVING

PWR POWER

QA QUALITY ASSURANCE

QC QUALITY CONTROL

QRY QUARRY

QT QUARRY TILE

QTB QUARRY TILE BASE

QTF QUARRY TILE FLOOR

QTR QUARTER

QTY QUANTITY

QUAD QUADRANT

QUAL QUALITY

R RADIUS OR RISER

RA RETURN AIR

RAD RADIATOR

RB RESILIENT BASE OR RUBBER BASE

RB HK ROBE HOOK

RBM REINFORCED BRICK MASONRY

RBR RUBBER

RC REMOTE CONTROL

RCP REFLECTED CEILING PLAN

RCVR RECEIVER

RD ROAD OR ROOF DRAIN

REC RECESSED

RECD RECEIVED

RECPT RECEPTACLE

RECT RECTANGLE

REF REFERENCE OR REFRIGERATOR

REFR REFRACTORY REFRIGERATION

REFR REFRIGERATION REFRACTORY

REG REGISTER

REINF REINFORCE

REP REPAIR

REPL REPLACE

REQ REQUIRE

REQD REQUIRED

RESIL RESILIENT

RET RETURN

REV REVISION

RF RADIO FREQUENCY

RFG ROOFING

RFI REQUEST FOR INFORMATION

RFP REQUEST FOR PROPOSAL

RH RIGHT HAND

RHMS ROUND HEAD MACHINE SCREW

RHR RIGHT HAND REVERSE

RHWS ROUND HEAD WOOD SCREW

RL ROOF LEADER

RLG RAILING

RM ROOM

RND ROUND

RO ROUGH OPENING

ROW RIGHT OF WAY

RPM REVOLUTIONS PER MINUTE

RS ROUGH SAWN

RT RIGHT

RV ROOF VENT

RVS REVERSE

RWD REDWOOD

RWL RAIN WATER LEADER

SA SUPPLY AIR

SALV SALVAGE

SAMP SAMPLE

SAN SANITARY

SAT SUSPENDED ACOUSTICAL TILE

SATC SUSPENDED ACOUSTICAL TILE CEILING

SB SPLASH BLOCK

SBS STYRENE BUTADIEN STYRENE

SBSTR SUBSTRATE

SC SHADING COEFFICIENT OR SOLID CORE

SCH SCHOOL

SCHED SCHEDULE

SCHEM SCHEMATIC

SCP SCUPPER

SCRN SCREEN

SCT STRUCTURAL CLAY TILE

SCWD SOLID CORE WOOD DOOR

SD SHOP DRAWINGS, SMOKE DETECTOR, OR

SOAP DISPENSER;

SDG SIDING

SECT SECTION

SEG SEGMENT

SEL SELECT

SEP SEPARATE

SF SQUARE FOOT (FEET)

SFTWD SOFTWOOD

SGD SLIDING GLASS DOOR

SGL SINGLE

SHR SHOWER

SHR HD SHOWER HEAD

SHRD SHOWER DRAIN

SHT SHEET

SHT MTL FLASH SHEET METAL (FLASHING)

SHTHG SHEATHING

SHV SHELVING

SIM SIMILAR

SJ SCORED JOINT

SJI STEEL JOIST INSTITUTE

SK SKETCH

SKLT SKYLIGHT

SLD WDW HORIZONTAL SLIDING WINDOW

SLDG SLIDING

SLNT SEALANT

SM SHEET METAL

SMK SMOKE

SND SANITARY NAPKIN DISPENSER

SND INS SOUND INSULATION

SNDU SANITARY NAPKIN DISPOSAL UNIT

SPEC SPECIFICATION

SPKLR SPRINKLER

SPKR SPEAKER

SPLY SUPPLY

SQ SQUARE

SQ IN SQUARE INCH

SQ YD SQUARE YARD

SS SANITARY SEWER OR SERVICE SINK

SST STAINLESS STEEL

ST STAIRS OR STREET

STC SOUND TRANSMISSION CLASS

STD STANDARD

STIF STIFFENER

STL JST STEEL JOIST

STL LNTL STEEL LINTEL

STL PL STEEL PLATE

STL RF DK STEEL ROOF DECK

STL TB STEEL TUBE

STL TR STEEL TRUSS

STNLS STAINLESS

STOR STORAGE

STR STRINGERS

STRUCT STRUCTURAL

STRUCT STL STRUCTURAL STEEL

SUB SUBSTITUTE

SURF SURFACE

SUSP SUSPEND

SUSP CLG SUSPENDED CEILING

SV SHEET VINYL

SW SWITCH

SWDR SWING DOOR

SYM SYMBOL

SYNTH SYNTHETIC

SYS SYSTEM

T TREAD

T&G TONGUE AND GROOVE

T&M TIME AND MATERIALS

TB THROUGH BOLT OR TOWEL BAR

TCA TILE COUNCIL OF AMERICA

TCP TELEPHONE CONTROL PANEL TEMPERATURE

CONTROL PANEL; TRAFFIC CONTROL PLAN

TD TOWEL DISPENSER

TECH TECHNICAL

TEL TELEPHONE

TEMP TEMPERATURE OR TEMPORARY

TER TERRAZZO

THD THREAD

THERM THERMAL

THK THICKNESS

THRES THRESHOLD

THRU THROUGH

THRUOUT THROUGHOUT

TK BD TACKBOARD

TMPD TEMPERED

TMPD GL TEMPERED GLASS

TN TRUE NORTH

TO TOP OF ___

TO FDN TOP OF FOUNDATION

TOB TOP OF BEAM

TOM TOP OF MASONRY

TOP TOP OF PARAPET

TOS TOP OF STEEL

TOW TOP OF WALL

TPD TOILET PAPER DISPENSER

TPH TOILET PAPER HOLDER

TR TOWEL RACK

TRANS TRANSOM

TRANS WD FINTRANSPARENT WOOD FINISH

TRTD TREATED

TS TENSILE STRENGTH OR TUBE STEEL

TSTAT THERMOSTAT

TV TELEVISION

TYP TYPICAL

U HEAT TRANSFER COEFFICIENT

UC UNDERCUT

UCD UNDERCUT DOOR

UGND UNDERGROUND

UL UNDERWRITERS LABORATORIES

ULT ULTIMATE

UNFIN UNFINISH

UON UNLESS OTHERWISE NOTED

UPS UNINTERRUPTIBLE POWER SUPPLY

UR URINAL

UTIL UTILITY

UV ULTRAVIOLET

V VOLT

VAC VACUUM

VAR VARIES

VCT VINYL COMPOSITION TILE VITRIFIED CLAY TILE

VEH VEHICLE

VENT VENTILATION

VERT VERTICAL

VEST VESTIBULE

VFAT VINYL FACED ACOUSTICAL TILE

VIC VICINITY

VID VIDEO

VIF VERIFY IN FIELD

VNR VENEER

VOC VOLATILE ORGANIC COMPOUND

VOL VOLUME

VOLT VOLTAGE

VP VENEER PLASTER

VR VAPOR RETARDER

VTR VENT THROUGH ROOF

VWC VINYL WALL COVERING

VWF VINYL WALL FABRIC

W WIDE OR WEST

W/ WITH

W/O WITHOUT

WARR WARRANTY

WBL WOOD BLOCKING

WC WALL COVERING OR WATER CLOSET

WC WL HNG WATER CLOSET, WALL HUNG

WCHR WATER CHILLER

WCL WL MTDWATER COOLER, WALL HUNG

WD WOOD

WDW WINDOW

WF WIDE FLANGE

WFAB WALL FABRIC

WFR WOOD FRAME

WFS WOOD FURRING STRIPS

WH WATER HEATER

WHSE WAREHOUSE

WLD WELDED

WM WIRE MESH

WP WATERPROOFING

WPD WATER PRESSURE DROP

WPM WATERPROOF MEMBRANE

WR WEATHER RESISTANT

WS WEATHERSTRIP

WSCT WAINSCOT

WT WEIGHT

WWF WELDED WIRE FABRIC

X BRACE CROSS BRACE

XPS EXTRUDED POLYSTYRENE BOARD (INSULATION)

YD YARD

YR YEAR

UNO

ACM ASBESTOS CONTAINING MATERIAL

ACP ACRYLIC GLAZING

SSF SOLID SURFACE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Central Texas Veterans Health

Care System

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhasePROJECT MANAGEMENT STAMPARCHITECT

321 4 5 6 7 8 9 10

10/13/2020

INTERIORSARCHITECTURE

COX DESIGN ASSOCIATES

PLANNING

Austin Chicago Denver El Paso

Austin, Texas 78746 5121 Bee Caves Road, Suite 203

BI

M

VA

T

EM

PL

E

C O

N

VE

R T

PA

TI

EN

T

R O

O M

S/

.2 0.

T

EM

PL

E_

C O

N

VE

R T_

BL

D

G

4_

PA

TI

EN

T_ R

M S.

rv t

/2

2/

:2 1:

P

M

GI-003

100% CONSTRUCTION

DOCUMENTS

ARCHITECTURAL ABBREVIATIONS CONVERT BUILDING 204

PATIENT ROOMS TO

PRIVATE ROOMS

1901 VETERANS MEMORIAL DRIVE

TEMPLE, TX. 76504

12/22/2020 RHC RJP

674-18-103

BUILDING IS

FULLY

SPRINKLED

8" MIN.

25" MAX.

(A) ELEVATION 11" MIN. (B) PLAN

2' - 4" MAX.

30" MIN.

17-25"

(A) ELEVATION (B) PLAN

2' - 6" MIN.

(A) (B)

2' - 10" MAX.

4' - 0" MAX. 2' - 10" MAX.

3' - 10" MAX.

20" MAX. >20-25" MAX

(A) (B)

48" MAX.

44" MAX.

15" MIN.

48" MAX.

1' - 3" MIN.

4' - 0" MAX.

1' - 8 1/2" 1' - 0 1/2"

A. PULL SIDE B. PUSH SIDE C. PUSH SIDE, DOOR PROVIDED

WITH BOTH CLOSER AND LATCH

5' - 0"

8"

8"

4' - 0"

8"

4' - 0"

24" MAX. 48" MIN. 24" MAX.

36" MIN.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhasePROJECT MANAGEMENT STAMPARCHITECT

321 4 5 6 7 8 9 10

Austin, Texas 78746 5121 Bee Caves Road, Suite 203

T:512 - 327 - 4149 F:512 - 327 - 7679

Austin bcox@coxdesignassociates.com

Central Texas Veterans Health

Care System

10/13/2020

INTERIORSARCHITECTURE

COX DESIGN ASSOCIATES

PLANNING

Chicago Denver El Paso

BI

M

VA

T

EM

PL

E

C O

N

VE

R T

PA

TI

EN

T

R O

O M

S/

.2 0.

T

EM

PL

E_

C O

N

VE

R T_

BL

D

G

4_

PA

TI

EN

T_ R

M S.

rv t

/2

2/

:2 2:

P

M

GI-004

100% CONSTRUCTION

DOCUMENTS

ACCESSIBILITY STANDARDS CONVERT BUILDING 204

PATIENT ROOMS TO

PRIVATE ROOMS

1901 VETERANS MEMORIAL DRIVE

TEMPLE, TX. 76504

12/22/2020 RHC RJP

674-18-103

SCALE: NTS1 KNEE CLEARANCE

SCALE: NTS2 TOE CLEARANCE

SCALE: NTS3 OBSTRUCTED HIGH SIDE REACH

SCALE: NTS6 OBSTRUCTED HIGH FORWARD REACH

SCALE: NTS7 UNOBSTRUCTED FORWARD REACH

SCALE: NTS4 UNOBSTRUCTED SIDE REACH

SCALE: NTS8 MANEUVERING CLEARANCES AT RECESSED DOORS AND GATES

SCALE: NTS5 CLEAR WIDTH OF AN ACCESSIBLE ROUTE

BUILDING IS

FULLY

40" 24"

A. FRONT OF REAR ENTRY B. SIDE ENTRY

48" MIN.

60" MIN.

36" MIN. 33" MIN. 33" MIN.

A. SINGLE SPACE B. TWO SPACES

24" MIN.

12" MIN. 22" MIN. 24" MIN.

F. FRONT APPROACH, PUSH SIDE, DOOR PROVIDED

WITH BOTH CLOSER AND LATCH

G. HINGE APPROACH, PUSH SIDE H. LATCH APPROACH, PUSH SIDE, DOOR

PROVIDED WITH CLOSER

I. LATCH APPROACH, PUSH SIDE

J. FRONT APPROACH, PUSH SIDE

22" MIN.

18" MIN CLEAR AT INTERIOR DOOR

PULL SIDE

PUSH SIDE

PULL SIDE

PUSH SIDE

42" MIN

PULL SIDE

PUSH SIDE

24" MIN.

A. FRONT APPROACH B. HINGE APPROACH, PULL SIDE C. LATCH SIDE APPROACH, PULL SIDE D. HINGE APPROACH, PUSH SIDE, DOOR

PROVIDED WITH BOTH CLOSER AND LATCH

E. LATCH APPROACH, PULL SIDE, DOOR

PROVIDED WITH CLOSER

60" MIN

42" MIN.

60" MIN 48" MIN

48" MIN

42" MIN.

54" MIN.

48" MIN.

36" MIN

17" - 25" MAX

CLEARANCES FOR COUNTERS

27" MIN

34" MAX

27" MIN

34" MAX

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhasePROJECT MANAGEMENT STAMPARCHITECT

321 4 5 6 7 8 9 10

Austin, Texas 78746 5121 Bee Caves Road, Suite 203

T:512 - 327 - 4149 F:512 - 327 - 7679

Austin bcox@coxdesignassociates.com

Central Texas Veterans Health

Care System

10/13/2020

INTERIORSARCHITECTURE

COX DESIGN ASSOCIATES

PLANNING

Chicago Denver El Paso

BI

M

VA

T

EM

PL

E

C O

N

VE

R T

PA

TI

EN

T

R O

O M

S/

.2 0.

T

EM

PL

E_

C O

N

VE

R T_

BL

D

G

4_

PA

TI

EN

T_ R

M S.

rv t

/2

2/

:2 2:

P

M

GI-005

100% CONSTRUCTION

DOCUMENTS

ACCESSIBILITY STANDARDS CONVERT BUILDING 204

PATIENT ROOMS TO

PRIVATE ROOMS

1901 VETERANS MEMORIAL DRIVE

TEMPLE, TX. 76504

12/22/2020 RHC RJP

674-18-103

SCALE: NTS1 CLEAR SPACE IN FRONT OF COUNTER

SCALE: NTS3 DEPTH OF WHEELCHAIR SPACES

SCALE: NTS4 WIDTH OF WHEELCHAIR SPACES

SCALE: NTS5 SWINGING DOOR APPROACH

SCALE: NTS2 MINIMUM CLEARANCE FOR COUNTER

BUILDING IS

FULLY

18"

OF FIXT

30" CLEAR

TOILET TISSUE

DISPENSER

42" GRAB

BAR

A. PLAN B. FRONT ELEVATION C. SIDE ELEVATION

54" MIN

OF FIXT

18"

36" MIN. 12" MIN. 6" 12" MAX

42"

42" GRAB BAR

7"-9" 1' - 6"

TOILET

TISSUE

DISPENSER,

PER PLANS

CL OPERABLE PART

OF ACCESSORY

6" MAX

60" MIN TO EDGE OF LAV 36" GRAB

BAR FROM WALL TO EDGE OF LAV

60"

48" CLEAR

19" MAX

56" MIN

12" MAX

TO VALVE

3'-8" MAX

TO TOP OF SEAT

17" - 19"

33" 19" MIN

40" MAX

12" MAX

66" MIN DIA CLEAR

OF LAV OF LAV

18" 28" MIN

TO FIXTURE

REFLECTIVE

POLYCARBONATE

MIRROR

SAFETY SOAP

DISPENSER

CLEAR FLOOR

SPACE

30" MIN

17" MIN

18"

8" MIN

INSULATE

EXPOSED PIPES

A. PLAN B. FRONT ELEVATION C. SIDE ELEVATION

MAX

6"

17" MIN

19" MAX

48" MIN

40" MAX

34" MAX

48" MAX

29"

9" MIN

27" MIN CLR

34" MAX

40" MAX

CODE CARD

FIRE ALARM STATION

DIGITAL

ALARM

SYSTEM

WALL

MOUNTED

COAT HOOK

DOOR

MOUNTED

COAT HOOKS

(4 '-0

" F O

R A

D A

IN

S

TA

LL

AT

IO

N S

CONTINUOUS FLOOR TO

CEILING CORNER

GUARD

MOP AND

BROOM

HOLDER

FIRE

EXTINGUISHER

CABINET

SWITCHES

FIRE

ALARM

PULL

ELECTRICAL &

TELEPHONE

RECEPTACLES

TV /

CABLE

OUTLET

THERMOSTATS

MASTER

PAGE

INTERCOM

MASTER

STATION

DUTY STATION

STAFF STATION

FOR REFERENCE ONLY - THIS DOES NOT INDICATE EQUIPMENT OR FIXTURES PROVIDED

FINISH CEILING

FINISH FLOOR

4'

6"

4'

0"

1' - 6"

1'

0"

5'

6"

3"

E

XI

S

TI

N G

M A

TC

H

M A

X

3'

6"

3'

1' - 0"

3'

6"

M A

X

4'

0"

1'

6"

9"

6"

9"

4'

6"

EQ EQ EQ

5'

0"

ROOM SIGNAGE

SEE SHEET AS-721

ACCESS CONTROL HARDWARE

DOOR PUSH

PLATE, 4'-0" MIN.

AWAY FROM DOOR

STRIKE IF LOCATED

ON AN ADJACENT

WALL

2'

MIN.

1' - 3"

6'

0"

1' - 0"

33" - 36" AFF

NOTE: PIPE DIMEN ARE SHOW AS NOM DIA

TOP OF GRAB BAR

4 - 4.8" PERIMETER

1 1/4"

1 1/4" MIN

2" MAX

NOTE:

2" MAX

ALLOWABLE

STRESSES SHALL

NOT BE

EXCEEDED FOR

MATERIALS USED

WHERE A

VERTICAL OR

HORIZONTAL

FORCE OF 250

LBS. IS APPLIED

AT ANY POINT ON

THE GRAB BAR,

FASTENER

MOUNTING

DEVICE OR

SUPPORTING

STRUCTURE.

PROVIDE 1 1/2"

MIN CLEAR

ACCESS AROUND

THE PERIMETER

OF THE GRAB BAR

2" MAX

1.5" MIN.

15"

A. PROJECTING OBJECTS B. RECESSED OBJECTS

8"

17"

MANUFACTURER

BY

19"

16"

PULL HANDLE

CLEAR ACRYLIC WINDOW

FACE OF WALL

180° DOOR SWING

15" MIN.

48" MAX.

7-9"

56" MIN.

60" MIN.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Central Texas Veterans Health

Care System

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhasePROJECT MANAGEMENT STAMPARCHITECT

321 4 5 6 7 8 9 10

10/13/2020

INTERIORSARCHITECTURE

COX DESIGN ASSOCIATES

PLANNING

Austin Chicago Denver El Paso

Austin, Texas 78746 5121 Bee Caves Road, Suite 203

BI

M

VA

T

EM

PL

E

C O

N

VE

R T

PA

TI

EN

T

R O

O M

S/

.2 0.

T

EM

PL

E_

C O

N

VE

R T_

BL

D

G

4_

PA

TI

EN

T_ R

M S.

rv t

/2

2/

:2 2:

P

M

GI-006

100% CONSTRUCTION

DOCUMENTS

ACCESSIBILITY STANDARDS CONVERT BUILDING 204

PATIENT ROOMS TO

PRIVATE ROOMS

1901 VETERANS MEMORIAL DRIVE

TEMPLE, TX. 76504

12/22/2020 RHC RJP

674-18-103

SCALE: 12" = 1'-0"1 SINGLE-ACCOMODATION TOILET ROOM

SCALE: 12" = 1'-0"2 ACCESSIBLE LAVATORY

SCALE: 1/4" = 1'-0"3 STANDARD MOUNTING DETAILS

SCALE: 12" = 1'-0"4 GRAB BAR NON-CIRCULAR CROSS SECTION

SCALE: 12" = 1'-0"5 SPACING OF GRAB BARS

SCALE: 12" = 1'-0"6 FIRE EXTINGUISHER CABINET - PLAN

SCALE: 12" = 1'-0"7 DISPENSER OUTLET LOCATION

SCALE: 12" = 1'-0"8 SIZE OF CLEARANCE AT WATER CLOSETS

BUILDING IS

FULLY

WY U R P N M H G FJ.5L E D C BKPATIENT

TOILET

4J22B

CONFERENCE

4J19 EQUIPMENT

4J28

CLEAN

UTILITY

4J29

NURSE

STATION

4J17

MEDICATION

PREP.

4J15

NOURISHMENT

4J16

STAFF

SUPPORT

ROOM

4J13

REPORT

ROOM

4J11

STORAGE ROOM

4J07

PATIENT ROOM

(ISOLATION)

4J30

PATIENT ROOM

(ISOLATION)

4J31

PATIENT ROOM

(ISOLATION)

4J32

PATIENT ROOM

(ISOLATION)

4J33

ANTE

ROOM

4J30A

ANTE

ROOM

4J31A

ANTE

ROOM

4J32A

ANTE

ROOM

4J33A

MECHANICAL

4K34

ELECTRICAL

4K06

H.A.C.

4K05

STORAGE ROOM

4K04

PATIENT ROOM

(ISOLATION)

4K35

ANTE

ROOM

4K35A

PATIENT ROOM

(ISOLATION)

4K36

ANTE

ROOM

4K36A

PATIENT ROOM

(ISOLATION)

4K37

ANTE

ROOM

4K37A

PATIENT ROOM

(ISOLATION)

4K38

ANTE

ROOM

4K38A

CLEAN

UTILITY

4K39

EQUIPMENT

4K40

SOILED

UTILITY

4K41

TEAM WORK/

CLASS ROOM

4K53

NOURISHMENT

4K56

MEDICATION

PREP.

4K55

TOILET

4K51B

STAFF

SUPPORT

ROOM

4K51

CLEAN LIN.

4K58

STORAGE

4K49

WORK

ROOM

4K50

PATIENT ROOM

4K46

PATIENT

TOILET

4K46B

BARIATRIC

PATIENT ROOM

4K45

PATIENT ROOM

4K44

PATIENT ROOM

4K43

PATIENT ROOM

4K42

CLEAN LIN.

4J18

SOILED

UTILITY

4J27

PATIENT ROOM

4J21

PATIENT ROOM

4J20

PATIENT

TOILET

4J21B

PATIENT ROOM

4J09

PATIENT ROOM

4J08

PATIENT ROOM

4K47

PATIENT ROOM

4K48

PATIENT ROOM

4K02

PATIENT ROOM

4K03

PATIENT

TOILET

4K47B

PATIENT

TOILET

4K48B

PATIENT

TOILET

4K02B

PATIENT

TOILET

4J08B

PATIENT

TOILET

4J09B

4J22B 10

4J21

4J20

4J19

4J27

4J28

4J29

4J20B

4J21B

4J30A

4J30 4J30B

4J31A

4J31 4J31B

4J32A

4J32 4J32B

4J33A

4J33 4J33B

4K34

4K354K35A

4K35B

4K36B

4K364K36A

4K37A 4K37

4K37B

4K38B

4K384K38A

4K39 4K40

4K41

4K46B 4K474K484K49

4K50

4K02 4K02B

4K03 4K03B

4K04

4K05

4K06

4J07

4J08

4J08B

4J09

4J09B

4J11

4J164J15

4J13

4K47B4K48B

4K51 4K51B

4K55

4K56 4K53B

4K53

CORRIDOR

4J61

4K46

4K43 4K444K42

PATIENT

TOILET

4J20B

PATIENT

TOILET

4K03B

PATIENT ROOM

4J22

BARIATRIC

PATIENT ROOM

4J23

PATIENT ROOM

4J24

PATIENT ROOM

4J25

PATIENT ROOM

4J26

4J24

4J25

4J26

4J22

WHL. CHR.

STOR.

4J14

WHL. CHR.

STOR.

4K54

4K58

STAIRS

STAIRS

AS-301

AS-301

FEC

FEC

FEC

FEC

FEC

FEC

FEC

CONFERENCE

ROOM

4K01

CONFERENCE

ROOM

4J10

TL. COM.

ROOM

4J12

TL. COM.

ROOM

4K52

AS-302

AS-302

J

NURSING STATION PNEUMATIC

TUBE SYSTEM

NURSING STATION PNEUMATIC

TUBE SYSTEM

AS-310

PATIENT

TOILET

4K45B

PATIENT

TOILET

4K44B

PATIENT

TOILET

4K43B

PATIENT

TOILET

4K42B

PATIENT

TOILET

4K38B

PATIENT

TOILET

4K37B

PATIENT

TOILET

4K36B

PATIENT

TOILET

4K35B

PATIENT

TOILET

4J33B

PATIENT

TOILET

4J32B

PATIENT

TOILET

4J31B

PATIENT

TOILET

4J30B

PATIENT

TOILET

4J26B

PATIENT

TOILET

4J25B

PATIENT

TOILET

4J24B

PATIENT

TOILET

4J23B

FEC

FEC

1 HOUR RATED FIRE

PARTITION

2 HOUR FIRE RATED

SMOKE BARRIER

1 HOUR FIRE RATED

SMOKE BARRIER

2 HOUR RATED FIRE

PARTITION

FIRE EXTINGUISHER

CABINET - SEMI RECESSEDFEC

NEW PARTITION

EXISTING PARTITION

PATH OF TRAVEL /

TRAVEL DISTANCE

85 FT

EXIT SIGN SINGLE SIDED EXIT SIGN SINGLE

SIDED DIRECTIONAL

EXIT SIGN DOUBLE SIDED EXIT SIGN DOUBLE

SIDED DIRECTIONAL

SMOKE

COMPARTMENT I

SMOKE

COMPARTMENT II

SMOKE PARTITION

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Central Texas Veterans Health

Care System

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhasePROJECT MANAGEMENT STAMPARCHITECT

321 4 5 6 7 8 9 10

10/13/2020

INTERIORSARCHITECTURE

COX DESIGN ASSOCIATES

PLANNING

Austin Chicago Denver El Paso

Austin, Texas 78746 5121 Bee Caves Road, Suite 203

BI

M

VA

T

EM

PL

E

C O

N

VE

R T

PA

TI

EN

T

R O

O M

S/

.2 0.

T

EM

PL

E_

C O

N

VE

R T_

BL

D

G

4_

PA

TI

EN

T_ R

M S.

rv t

/2

2/

:1 6:

P

M

AI-100

100% CONSTRUCTION

DOCUMENTS

4TH FLOOR - LIFE SAFETY PLAN CONVERT BUILDING 204

PATIENT ROOMS TO

PRIVATE ROOMS

1901 VETERANS MEMORIAL DRIVE

TEMPLE, TX. 76504

12/22/2020 RHC RJP

674-18-103

SCALE: 3/32" = 1'-0"1 4TH FLOOR - LIFE SAFETY PLAN BUILDING IS

FULLY

SPRINKLED

N

NFPA 101 LIFE SAFETY CODE CRITERIA:

CHAPTER 7 MEANS OF EGRESS

7.2.1.2.3.2 DOOR OPENINGS

32" DOOR OPENING REQUIRED, 42" DOOR OPENING PROVIDED

TABLE 7.2.2.2.1.2 NEW STAIR WIDTH

44" STAIR WIDTH REQUIRED, 48" STAIR WIDTH PROVIDED

TABLE 7.3.1.2 OCCUPANT LOAD

AMBULATORY HEALTH CARE: 150 SF / PERSON

24,860 GSF / 150 SF = 166 OCCUPANTS

OCCUPANT LOAD: 166

TABLE 7.3.3.1 CAPACITY FACTORS

MEANS OF EGRESS:

STAIRS - 166 OCCUPANTS, 3 EXIT STAIRS PROVIDED EACH SERVING 56 OCCUPANTS

CHAPTER 18 NEW HEALTH CARE OCCUPANCY

18.1.6.1 MINIMUM CONSTRUCTION REQUIREMENTS

TYPE I (442) CONSTRUCTION, FULLY SPRINKLERED

18.2.3 CAPACITY OF MEANS OF EGRESS

18.2.3.4 (1) 44" CORRIDOR REQUIRED, 72" CORRIDOR PROVIDED

18.2.6 TRAVEL DISTANCE TO EXITS

18.2.6.2.1 200' MAXIMUM

NFPA 220 STANDARD ON TYPES OF BUILDING CONSTRUCTION:

TABLE 4.1.1, TYPE 1 (442)

COLUMNS, SUPPORTING MORE THAN ONE FLOOR - 4 HOUR FIRE RATING

4 HOUR SPRAY-ON FIREPROOFING PER UL DESIGN X701

BEAMS, SUPPORTING ONE FLOOR ONLY - 2 HOUR FIRE RATING

2 HOUR SPRAY-ON FIREPROOFING PER UL DESIGN N706

FLOOR-CEILING ASSEMBLIES - 2 HOUR FIRE RATING

2 HOUR SPRAY-ON FIREPROOFING PER UL DESIGN N706

ROOF-CEILING ASSEMBLIES - 2 HOUR FIRE RATING

2 HOUR SPRAY-ON FIREPROOFING PER UL DESIGN N706

INTERIOR NONBEARING WALLS - 0 FIRE RATING

EXTERIOR NONBEARING WALLS - 0 FIRE RATING

CODES AND STANDARDS:

LATEST EDITIONS

2018 NFPA 101 LIFE SAFETY CODE

2018 NFPA 220 STANDARDS FOR BUILDING CONSTRUCTION TYPES

INTERNATIONAL BUILDING CODE

INTERNATIONAL MECHANICAL CODE

INTERNATIONAL PLUMBING CODE

INTERNATIONAL ELECTRIC CODE

VA FIRE PROTECTION DESIGN MANUAL

A. BUILDING IS TO HAVE A FULLY AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH

NFPA 101. RE. FIRE PROTECTION DRAWINGS FOR ADDITIONAL INFORMATION.

B. EXIT STAIR ENCLOSURES ARE TWO HOUR RATED FOR HEALTH CARE OCCUPANCY

(HC).

C. ALL PARTITIONS SHOWN WITHOUT FIRE RATING ARE NON-RATED U.N.O.

D. DURING DEMOLITION AND NEW CONSTRUCTION PHASES, CONTRACTOR SHALL

MAINTAIN REQUIRED RATING AT ALL EXISTING WALLS, FLOORS AND ROOFS TO REMAIN.

E. REFER TO SHEET 1-AS-620, TECHNOLOGY AND ELECTRICAL DRAWINGS FOR DOOR

SCHEDULE, NUMBER, HARDWARE, RATING AND SECURITY INFORMATION.

F. CONTRACTOR SHALL COORDINATE WITH ALL DISCIPLINE DRAWINGS FOR ADDITIONAL

INFORMATION.

G. ALL DOORS IN A RATED PARTITION OR SMOKE PARTITION SHALL HAVE THE

APPROPRIATE RATING TO CORRESPOND WITH WALL.

H. REFER TO SHEET 1-AS-530 FOR PARTITION TYPES.

I. UNLESS OTHERWISE NOTED, ALL AREAS ARE HEALTH CARE (HC) OCCUPANCY.

J. ALL PORTIONS OF HEALTH CARE (HC) OCCUPANCY TO THE NEAREST EXIT ARE WITHIN

200 FEET.

GENERAL NOTES

LEGEND

MATCH LINEMATCH LINE

AD-104.2

AD-104.1

AD-104.2

AD-104.1

STAIRS

STAIRS

PH

AS

E I

PH

AS

E

II

PH

AS

E I

PH

AS

E

II

DASHED LINE

DENOTES ITEM TO

BE DEMOLISHED

EXISTING TO REMAIN

EXISTING PARTITION

TO REMAIN

LIMITS OF

CONSTRUCTION

ALL EXISTING INTERIOR WALLS, FINISHES, FLOORING, AND COMPLETE CEILING

ASSEMBLIES TO BE REMOVED FROM 4TH FLOOR FLOOR SLAB TO THE BOTTOM OF

5TH FLOOR FLOOR SLAB AND TO INTERIOR FINISH OF EXTERIOR/CORE WALLS

AND COLUMNS.

REMOVE EXISTING PLUMBING FIXTURES. SEE PLUMBING DRAWINGS FOR FULL

EXTENT OF DEMOLITION.

EXISTING MECHANICAL IN-WALL STEAM RADIATOR CABINETS TO REMAIN AND

CONTAINING MATERIALS AND EQUIPMENT TO BE REMOVED AND DISCARDED.

SUPPLY COPPER PIPE TO BE CAPPED OFF BELOW SLAB. REFERENCE

ENGINEERING DRAWINGS FOR PLUMBING, ELECTRICAL, FIRE, AND MECHANICAL

EQUIPMENT AND FIXTURE DEMOLITION WORK.

VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE. 1.

VERIFY EXACT COMPOSITION OF EXISTING WALLS TO BE REMOVED.2.

REMOVE FLOOR FINISHES, AND MASTIC INCLUDING SETTING BED IN CERAMIC TILE

AREAS IF APPLICABLE.

3.

REMOVE SUSPENDED CEILING ASSEMBLIES, RELATED HANGERS AND ANCHORS,

OR GYPSUM BOARD/ PLASTER CEILINGS WHERE NEW CEILINGS ARE INDICATED

ON REFLECTED CEILING PLAN OR ROOM FINISH SCHEDULE.

4.

REMOVE ALL EXISTING CEILING, FLOOR, WALL ACCESSORIES INCLUDING HARD

CEILINGS, ACOUSTICAL TILE CEILINGS, CEILING GRID AND SUPPORTS, ALL

APPLIED FINISHES TO SUBSTRATE, LIGHT FIXTURES, PLUMBING FIXTURES,

DOORS, DOOR FRAMES, DOOR HARDWARE, WALL BASE, GRILLES, DIFFUSERS,

OUTLETS, FACEPLATES, FLOOR FINISH SYSTEMS, CASEWORK, WAYFINDING AND

SIGNAGE.

5.

REMOVE EXISTING WALL FINISHES IN ROOMS WHERE NEW FINISHES ARE

INDICATED IN THE ROOM FINISH SCHEDULE. EXISTING WALLS TO BE PREPARED

AS REQUIRED TO ACCEPT NEW SCHEDULED FINISHES.

6.

AT EXISTING WALLS SHOWN TO REMAIN (INCLUDING EXTERIOR WALLS). THE

EXISTING COVED TILE/ TERRAZZO BASE IS TO BE REMOVED AND INFILLED IN

PREPARATION FOR NEW WALL BASE AND FINISHES TO BE INSTALLED PER THE

ROOM FINISH SCHEDULE. EXISTING TERRAZZO DIVIDER STRIP TO BE GROUND

DOWN OR REMOVED. SEE SHEET AS-536.

7.

REFER TO PLUMBING HVAC AND ELECTRICAL PLANS FOR ADDITIONAL DEMOLITION

ITEMS AND NOTES. COORDINATE WORK WITH PLUMBING, HVAC AND ELECTRICAL

REQUIREMENTS.

8.

MAINTAIN CONTINUOUS UTILITY SERVICE TO ALL SPACES IN THE BUILDING NOT

AFFECTED BY THIS WORK. COORDINATE WITH OWNER ANY DISRUPTION IN SERIES

REQUIRED TO PERFORM WORK OR TO MODIFY EXISTING PIPING, DUCTWORK, OR

ANY ASSOCIATED EQUIPMENT.

9.

ALL EXISTING ABANDONED MECHANICAL EQUIPMENT AND ALL ASSOCIATED

PIPING DISCOVERED DURING DEMOLITION IS TO BE REMOVED AND DISCARDED

BY CONTRACTOR.

10.

REMOVE ALL COLUMN FINISHES AND UTILITIES, INCLUDING GYPSUM BOARD AND

FURRINGS FROM EXISTING STRUCTURAL COLUMNS. NEW WALL FURRINGS ARE

TO BE PROVIDED AT ALL COLUMNS AS PART OF NEW CONSTRUCTION WHETHER

SPECIFICALLY NOTED ON FLOOR PLAN OR NOT.

11.

12. ALL ABANDONED PIPING INCLUDING ABANDONED PNEUMATIC TUBES TO BE

REMOVED AND DISCARDED BY CONTRACTOR

13. REMOVE ALL CEILINGS AND CEILING SUBSTRATE LOCATED IN PROJECT AREA

INCLUDING PLASTER CEILINGS ABOVE 4TH FLOOR CEILING.

14. WALLS AND SUBSTRATE MATERIAL LOCATED AT COLUMNS TO BE REMOVED BACK

TO CONCRETE COLUMN

15. DEMO TO BE COORDINATED WITH ASBESTOS ABATEMENT.

16.

17.

18.

ALL EXISTING COLUMNS, BEAMS, LOAD BEARING WALLS AND STRUCTURAL

ASSEMBLIES TO REMAIN, PROTECT DURING CONSTRUCTION.

19.

ALL EXISTING EXTERIOR WINDOW ASSEMBLIES TO REMAIN, REMOVE TRIM AND

SILLS AND PREPARE INTERIOR ADJACENT SURFACES FOR NEW FINISHES AS

SCHEDULED.

20.

CONTRACTOR TO MAINTAIN ALL EXIT ACCESS PATHS DURING ALL PHASES OF

DEMOLITION OR NEW CONSTRUCTION.

21.

CONTRACTOR TO COMPLY WITH ALL ICRA REQUIREMENTS AT THE OLIN E.

TEAGUE VETERANS' MEDICAL CENTER.

22.

COORDINATE LOCATIONS OF ALL ANTE ROOM TEMPORARY BARRIER WALLS AND

DOORS WITH THE VA COR FOR EACH PHASE.

23.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Central Texas Veterans Health

Care System

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhasePROJECT MANAGEMENT STAMPARCHITECT

321 4 5 6 7 8 9 10

10/13/2020

INTERIORSARCHITECTURE

COX DESIGN ASSOCIATES

PLANNING

Austin Chicago Denver El Paso

Austin, Texas 78746 5121 Bee Caves Road, Suite 203

BI

M

VA

T

EM

PL

E

C O

N

VE

R T

PA

TI

EN

T

R O

O M

S/

.2 0.

T

EM

PL

E_

C O

N

VE

R T_

BL

D

G

4_

PA

TI

EN

T_ R

M S.

rv t

/2

2/

:1 5:

P

M

AD-104

100% CONSTRUCTION

DOCUMENTS

4TH FLOOR - DEMOLITION PLAN CONVERT BUILDING 204

PATIENT ROOMS TO

PRIVATE ROOMS

1901 VETERANS MEMORIAL DRIVE

TEMPLE, TX. 76504

12/22/2020 RHC RJP

674-18-103

SCALE: 1/16" = 1'-0"1 4TH FLOOR - DEMO

N

BUILDING IS

FULLY

SPRINKLED

GENERAL NOTES

AD-104.2 AD-104.2

5 5

AS-310

DASHED LINE

DENOTES ITEM TO

BE DEMOLISHED

EXISTING TO REMAIN

EXISTING PARTITION

TO REMAIN

LIMITS OF

CONSTRUCTION

TEMPORARY

BARRIER WALL (1HR

FIRE RATED)

INFILL SHOWER

DEPRESSION

ALL EXISTING INTERIOR WALLS, FINISHES, FLOORING, AND COMPLETE CEILING

ASSEMBLIES TO BE REMOVED FROM 4TH FLOOR FLOOR SLAB TO THE BOTTOM OF

5TH FLOOR FLOOR SLAB AND TO INTERIOR FINISH OF…

This is the start of the file's text. The full file is on GovTribe.