2019 01 30_Kville West Elem MC Reno_Addendum 1-1.pdf

PDF 3 MB Posted

Attached to
Kelloggsville West Elementary Media Center Renovation
Solicitation number
RFP-KEL-190000000773-3
Issued by
Kent County, Michigan

About this file

This is Addendum No. 1 issued by TowerPinkster for the West Elementary Media Center Renovation project at Kelloggsville Public Schools in Grand Rapids, MI. The project involves renovating the media center, computer lab, and surrounding rooms, as well as demolishing a stage to create a new storage room. The project is split into four bid categories: General Trades, Flooring, Mechanical, and Electrical. A pre-bid meeting was held on January 22, 2019, with bids due February 6, 2019 at 3:30pm. Post-bid interviews are scheduled for February 11, 2019. Construction is planned to begin June 7, 2019 with substantial completion by August 23, 2019.

The addendum includes specifications for solid surfacing fabrications, door hardware updates, and visual display units. Notable clarifications include removal of Alternate #1 (EIFS with metal siding), updates to door hardware specifications to show 4 sets instead of 18, and assignment of added specifications 06 6116 and 10 1100 to Bid Category 1 - General Trades. Key technical updates include lintel sizes for borrowed lights and doors, clarification that Door 115A is wood with hollow metal frame, and confirmation that borrowed lights require double bullnose CMU sills. The project does not require prevailing wages. Temporary facilities will be provided, and existing electrical and water services will be available for contractor use.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ADDENDUM NO. 1

See attached Prebid Meeting Minutes and RFI/Responses

ADD-1 Item No. S-1 -

ADD-1 Item No. S-2 -

ADD-1 Item No. S-3 -

ADD-1 Item No. D-1 -

ADD-1 Item No. D-2 -

ADD-1 Item No. D-3 -

ADD-1 Item No. D-4 -

ADD-1 Item No. D-5 -

ADD-1 Item No. D-6 -

ADD-1 Item No. D-7 -

ADD-1 Item No. D-8 -

PROJECT NO. 12-194.45 SOLID SURFACING FABRICATIONS

KELLOGGSVILLE PUBLIC SCHOOLS 06 6116 - 1

WEST ELEMENTARY MEDIA CENTER RENO ADDENDUM 1 - 01/30/19

SECTION 06 6116 - SOLID SURFACING FABRICATIONS

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes: Solid-surface-material fabrications including the following:

1. Window stools.

1.2 ACTION SUBMITTALS

A. Product Data: For solid surfacing materials.

B. Shop Drawings: Show materials, finishes, edge profiles, and methods of joining.

1.3 PROJECT CONDITIONS

A. Field Measurements: Verify dimensions of fabrications by field measurements.

PART 2 - PRODUCTS

2.1 SOLID-SURFACE-MATERIAL FABRICATIONS

A. Provide fabrications as indicated on Drawings.

2.2 MATERIALS

A. Particleboard: ANSI A208.1, Grade M-2-Exterior Glue.

B. Solid Surface Material (SSM-1): Homogeneous solid sheets of filled plastic resin complying with

ANSI SS1.

1. Product: E. I. du Pont de Nemours and Company; Corian.

2. Type: Provide Standard Type unless Special Purpose Type is indicated.

3. Colors and Patterns: Vanilla.

PART 3 - EXECUTION

3.1 INSTALLATION

A. Install window stools level to a tolerance of 1/8 inch in 8 feet (3 mm in 2.4 m).

ADDENDUM 1

© 2019 Tower Pinkster Titus Associates - All Rights Reserved

PROJECT NO. 12-194.45 SOLID SURFACING FABRICATIONS

KELLOGGSVILLE PUBLIC SCHOOLS 06 6116 - 2

WEST ELEMENTARY MEDIA CENTER RENO ADDENDUM 1 - 01/30/19

B. Fasten window stools by adhering to substrate. Align adjacent surfaces and, using adhesive in color to match countertop, form seams to comply with manufacturer's written instructions. Carefully dress joints smooth, remove surface scratches, and clean entire surface.

END OF SECTION 06 6116

DOOR HARDWARE

PROJECT NO. 12-194.45 08 7100 - 1

KELLOGSVILLE PUBLIC SCHOOLS

WEST ELEMENTARY MEDIA CENTER RENO.

SECTION 08 7100 - DOOR HARDWARE

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1. Mechanical door hardware for the following:

a. Swinging doors.

2. Cylinders for door hardware specified in other Sections.

3. Electrified door hardware.

B. Related Requirements:

1. Section 08 1113 "Hollow Metal Doors and Frames" and for door silencers provided as part of hollow-metal frames.

2. Section 08 1416 "Flush Wood Doors" for astragals and integral intumescent seals provided as part of labeled fire-rated assemblies.

3. Section 08 3113 "Access Doors and Frames" for access door hardware.

4. Section 08 4113 "Aluminum-Framed Entrances and Storefronts" for hardware specified as a part of that system.

5. Section 28 3100 "Fire Detection and Alarm" for connections to building fire-alarm system.

1.2 ACTION SUBMITTALS

A. Product Data: For each type of product indicated.

B. Shop Drawings: Details of electrified door hardware, indicating the following:

1. Wiring Diagrams: For power, signal, and control wiring and including the following:

a. Details of interface of electrified door hardware and building safety and security systems.

b. Schematic diagram of systems that interface with electrified door hardware.

c. Point-to-point wiring.

d. Risers.

e. Elevations doors controlled by electrified door hardware.

2. Operation Narrative: Describe the operation of doors controlled by electrified door hardware.

a. At all doors with access control, the following is mandatory:

1) Wiring drawing showing point to point wire hook up of all components.

ADDENDUM 1 - 01/30/19

PROJECT NO. 12-194.45 08 7100 - 2

2) System operation description for each type of opening: describe each possible condition.

3) Supervision of final hook-up for all electrified hardware.

4) Riser, wiring diagrams and system operational description must be furnished for approval before installation is to commence. Required instruction shall be provided to owner regarding operation of all electronic hardware

5) Every effort should be made to accommodate for repair, replacement or alterations to field wiring terminated in junction box’s.

C. Other Action Submittals:

1. Door Hardware Schedule: Prepared by or under the supervision of Installer, detailing fabrication and assembly of door hardware, as well as installation procedures and diagrams. Coordinate final door hardware schedule with doors, frames, and related work to ensure proper size, thickness, hand, function, and finish of door hardware.

a. Submittal Sequence: Submit door hardware schedule concurrent with submissions of Product Data, Samples, and Shop Drawings. Coordinate submission of door hardware schedule with scheduling requirements of other work to facilitate the fabrication of other work that is critical in Project construction schedule.

b. Format: Comply with scheduling sequence and vertical format in DHI's "Sequence and Format for the Hardware Schedule." Double space entries, and number and date each page.

c. Format: Use same scheduling sequence and format and use same door numbers as in the Contract Documents.

d. Content: Include the following information:

1) Identification number, location, hand, fire rating, size, and material of each door and frame.

2) Locations of each door hardware set, cross-referenced to Drawings on floor plans and to door and frame schedule.

3) Complete designations, including name and manufacturer, type, style, function, size, quantity, function, and finish of each door hardware product.

4) Description of electrified door hardware sequences of operation and interfaces with other building control systems.

5) Fastenings and other pertinent information.

6) Explanation of abbreviations, symbols, and codes contained in schedule.

7) Mounting locations for door hardware.

8) List of related door devices specified in other Sections for each door and frame.

2. Keying Schedule: Prepared by or under the supervision of Installer, detailing Owner's final keying instructions for locks. Include schematic keying diagram and index each key set to unique door designations that are coordinated with the Contract Documents.

1.3 INFORMATIONAL SUBMITTALS

A. Qualification Data: For Architectural Hardware Consultant.

PROJECT NO. 12-194.45 08 7100 - 3

B. Product Certificates: For electrified door hardware, from the manufacturer.

1. Certify that door hardware approved for use on types and sizes of labeled fire-rated doors complies with listed fire-rated door assemblies.

C. Warranty: Special warranty specified in this Section.

1.4 CLOSEOUT SUBMITTALS

A. Maintenance Data: For each type of door hardware to include in maintenance manuals. Include final hardware and keying schedule.

1.5 QUALITY ASSURANCE

A. Installer Qualifications: Supplier of products and an employer of workers trained and approved by product manufacturers and an Architectural Hardware Consultant who is available during the course of the Work to consult with Contractor, Architect, and Owner about door hardware and keying.

B. Architectural Hardware Consultant Qualifications: A person who is experienced in providing consulting services for door hardware installations that are comparable in material, design, and extent to that indicated for this Project and who is currently certified by DHI as follows:

1. For door hardware, an Architectural Hardware Consultant (AHC)

C. Source Limitations: Obtain each type of door hardware from a single manufacturer.

D. Fire-Rated Door Assemblies: Where fire-rated door assemblies are indicated, provide door hardware rated for use in assemblies complying with NFPA 80 that are listed and labeled by a qualified testing agency, for fire-protection ratings indicated, based on testing at positive pressure according to NFPA 252 or UL 10C, unless otherwise indicated.

E. Smoke- and Draft-Control Door Assemblies: Where smoke- and draft-control door assemblies are required, provide door hardware that meet requirements of assemblies tested according to UL 1784 and installed in compliance with NFPA 105.

1. Air Leakage Rate: Maximum air leakage of 0.3 cfm/sq. ft. (3 cu. m per minute/sq. m) at the tested pressure differential of 0.3-inch wg (75 Pa) of water.

F. Electrified Door Hardware: Listed and labeled as defined in NFPA 70, Article 100, by a testing agency acceptable to authorities having jurisdiction.

G. Means of Egress Doors: Latches do not require more than 15 lbf (67 N) to release the latch. Locks do not require use of a key, tool, or special knowledge for operation.

H. Accessibility Requirements: Comply with applicable provisions in the DOJ's 2010 ADA Standards for Accessible Design and ICC A117.1 for door hardware on doors in an accessible route.

PROJECT NO. 12-194.45 08 7100 - 4

1. Provide operating devices that do not require tight grasping, pinching, or twisting of the wrist and that operate with a force of not more than 5 lbf (22.2 N).

2. Comply with the following maximum opening-force requirements:

a. Interior, Non-Fire-Rated Hinged Doors: 5 lbf (22.2 N) applied perpendicular to door.

b. Sliding or Folding Doors: 5 lbf (22.2 N) applied parallel to door at latch.

c. Fire Doors: Minimum opening force allowable by authorities having jurisdiction.

3. Bevel raised thresholds with a slope of not more than 1:2. Provide thresholds not more than 1/2 inch (13 mm) high.

4. Closers: Adjust door and gate closer sweep periods so that, from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum.

5. Spring Hinges: Adjust door and gate spring hinges so that, from an open position of 70 degrees, the time required to move the door to the closed position is 1.5 seconds minimum.

I. Keying Conference: Conduct conference at Project site to comply with requirements in Division 01 Section "Project Management and Coordination."

1.6 DELIVERY, STORAGE, AND HANDLING

A. Inventory door hardware on receipt and provide secure lock-up for door hardware delivered to Project site.

B. Tag each item or package separately with identification coordinated with the final door hardware schedule, and include installation instructions, templates, and necessary fasteners with each item or package.

C. Deliver keys to manufacturer of key control system for subsequent delivery to Owner.

D. Deliver keys and permanent cores to Owner by registered mail or overnight package service.

1.7 COORDINATION

A. Installation Templates: Distribute for doors, frames, and other work specified to be factory prepared.

Check Shop Drawings of other work to confirm that adequate provisions are made for locating and installing door hardware to comply with indicated requirements.

B. Electrical System Roughing-In: Coordinate layout and installation of electrified door hardware with connections to power supplies and building safety and security systems.

C. Existing Openings: Where hardware components are scheduled for application to existing construction or where modifications to existing door hardware are required, field verify existing conditions and coordinate installation of door hardware to suit opening conditions and to provide proper door operation.

PROJECT NO. 12-194.45 08 7100 - 5

1.8 WARRANTY

A. Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace components of door hardware that fail in materials or workmanship within specified warranty period.

1. Warranty Period: Three years from date of Substantial Completion, unless otherwise indicated.

a. Exit Devices: Two years from date of Substantial Completion.

b. Manual Closers: 30 years from date of Substantial Completion.

1.9 MAINTENANCE SERVICE

A. Maintenance Tools and Instructions: Furnish a complete set of specialized tools and maintenance instructions for Owner's continued adjustment, maintenance, and removal and replacement of door hardware.

PART 2 - PRODUCTS

2.1 SCHEDULED DOOR HARDWARE

A. Provide door hardware for each door as scheduled in Part 3 "Door Hardware Schedule" Article to comply with requirements in this Section.

1. Door Hardware Sets: Provide quantity, item, size, finish or color indicated, and products equivalent in function and comparable in quality to named products by other listed manufacturers.

2. Sequence of Operation: Provide electrified door hardware function, sequence of operation, and interface with other building control systems indicated.

2.2 HINGES

A. Hinges: BHMA A156.1. Provide template-produced hinges for hinges installed on hollow-metal doors and hollow-metal frames.

1. Basis-of-Design Product: Subject to compliance with requirements, provide product indicated on schedule or comparable product by one of the following:

a. Hager Companies.

b. IVES Hardware; an Allegion company.

c. McKinney Products Company; an ASSA ABLOY Group company.

d. Stanley Commercial Hardware; Div. of The Stanley Works.

B. Continuous Hinges: BHMA A156.26; minimum 0.120-inch- (3.0-mm-) thick, hinge leaves with minimum overall width of 4 inches (102 mm); fabricated to full height of door and frame and to template screw locations; with components finished after milling and drilling are complete.

PROJECT NO. 12-194.45 08 7100 - 6

1. Continuous, Gear-Type Hinges: Extruded-aluminum, pinless, geared hinge leaves joined by a continuous extruded-aluminum channel cap; with concealed, self-lubricating thrust bearings.

a. Basis-of-Design Product: Subject to compliance with requirements, provide product indicated on schedule or comparable product by one of the following:

1) Hager Companies.

2) IVES Hardware; an Allegion company.

3) McKinney Products Company; an ASSA ABLOY Group company.

4) Select Products Limited.

5) Stanley Commercial Hardware; Div. of The Stanley Works.

2.3 MORTISE LOCKS

A. All locks shall be Schlage L9000 series to meet Owners standard. Verify lock function with Owner prior to ordering.

2.4 ELECTRIC STRIKES

A. Electric Strikes: BHMA A156.31; Grade 1; with faceplate to suit lock and frame.

1. Basis-of-Design Product: Subject to compliance with requirements, provide product indicated on schedule or comparable product by one of the following:

a. Von Duprin 6000 series; an Allegion company.

2.5 EXIT DEVICES AND AUXILIARY ITEMS

A. Exit Devices and Auxiliary Items: BHMA A156.3.

1. Basis-of-Design Product: Subject to compliance with requirements, provide product indicated on schedule or comparable product by one of the following:

a. Von Duprin 98/35 series; No Substitute.

2.6 LOCK CYLINDERS

A. Lock Cylinders: Tumbler type, constructed from brass or bronze, stainless steel, or nickel silver.

1. Supply cylinders compatible with Owners existing key system as directed by Owner on exterior doors and new key system on interior doors as directed by Owner.

2. Basis-of-Design Product: Subject to compliance with requirements, provide product indicated on schedule or comparable product by one of the following:

a. Schlage Primus.

PROJECT NO. 12-194.45 08 7100 - 7

2.7 KEYING

A. Keying System: Factory registered, complying with guidelines in BHMA A156.28, Appendix A.

Incorporate decisions made in keying conference.

1. Existing System:

a. Match Existing Key system on exterior doors as Directed by Owner. Final cores and keying on exterior doors to be supplied by Architectural Hardware, Muskegon, MI to be keyed into existing systems. Provide new Grand Master key system on interior doors as directed by owner. Conduct keying meeting with Owner to determine keying requirements:

B. Keys: Nickel silver

1. Stamping: Permanently inscribe each key with a visual key control number and include the following notation:

a. Notation: "DO NOT DUPLICATE."

2. Quantity: In addition to one extra key blank for each lock, provide the following:

a. Cylinder Change Keys: Three.

2.8 OPERATING TRIM

A. Operating Trim: BHMA A156.6; stainless steel, unless otherwise indicated.

1. Basis-of-Design Product: Subject to compliance with requirements, provide product indicated on schedule or comparable product by one of the following:

a. Burns Manufacturing Incorporated.

b. Don-Jo Mfg., Inc.

c. Forms + Surfaces.

d. Hager Companies.

e. Hiawatha, Inc.

f. IVES Hardware; an Allegion company.

g. Rockwood Manufacturing Company.

h. Trimco.

2.9 ACCESSORIES FOR PAIRS OF DOORS

A. Coordinators: BHMA A156.3; consisting of active-leaf, hold-open lever and inactive-leaf release trigger;

fabricated from steel with nylon-coated strike plates; with built-in, adjustable safety release.

B. Astragals: BHMA A156.22.

PROJECT NO. 12-194.45 08 7100 - 8

2.10 CLOSERS

A. Surface Closers: BHMA A156.4; rack-and-pinion hydraulic type with adjustable sweep and latch speeds controlled by key-operated valves and forged-steel main arm. Comply with manufacturer's written recommendations for size of door closers depending on size of door, exposure to weather, and anticipated frequency of use. Provide factory-sized closers, adjustable to meet field conditions and requirements for opening force.

1. Basis-of-Design Product: Subject to compliance with requirements, provide product indicated on schedule or comparable product by one of the following:

a. LCN 4040XP Closers; No Substitute.

2.11 STOPS AND HOLDERS

A. Wall- and Floor-Mounted Stops: BHMA A156.16; polished cast brass, bronze, or aluminum base metal.

1. Basis-of-Design Product: Subject to compliance with requirements, provide product indicated on schedule or comparable product by one of the following:

a. IVES Hardware; an Allegion company.

b. Rockwood Manufacturing Company.

c. Stanley Commercial Hardware; Div. of The Stanley Works.

d. Trimco.

B. Overhead Stops and Holders: BHMA A156.8.

1. Basis-of-Design Product: Subject to compliance with requirements, provide product indicated on schedule or comparable product by one of the following:

a. Glynn-Johnson; an Allegion company.

2.12 ELECTROMAGNETIC STOPS AND HOLDERS

A. Electromagnetic Door Holders: BHMA A156.15, Grade 1; unit with strike plate attached to swinging door;

coordinated with fire detectors and interface with fire-alarm system for labeled fire-rated door assemblies.

2.13 DOOR GASKETING

A. Door Gasketing: BHMA A156.22; air leakage not to exceed 0.50 cfm per foot (0.000774 cu. m/s per m) of crack length for gasketing other than for smoke control, as tested according to ASTM E 283; with resilient or flexible seal strips that are easily replaceable and readily available from stocks maintained by manufacturer.

1. Basis-of-Design Product: Subject to compliance with requirements, provide product indicated on schedule or comparable product by one of the following:

PROJECT NO. 12-194.45 08 7100 - 9

a. National Guard Products.

b. Pemko Manufacturing Co.; an ASSA ABLOY Group company.

c. Reese Enterprises, Inc.

d. Zero International.

2.14 THRESHOLDS

A. Thresholds: BHMA A156.21; fabricated to full width of opening indicated.

1. Basis-of-Design Product: Subject to compliance with requirements, provide product indicated on schedule or comparable product by one of the following:

a. National Guard Products.

b. Pemko Manufacturing Co.; an ASSA ABLOY Group company.

c. Reese Enterprises, Inc.

d. Zero International.

2.15 METAL PROTECTIVE TRIM UNITS

A. Metal Protective Trim Units: BHMA A156.6; fabricated from 0.050-inch- (1.3-mm-) thick stainless steel;

with manufacturer's standard machine or self-tapping screw fasteners.

1. Manufacturers: Any BHMA member.

2.16 FABRICATION

A. Manufacturer's Nameplate: Do not provide products that have manufacturer's name or trade name displayed in a visible location except in conjunction with required fire-rated labels and as otherwise approved by Architect.

1. Manufacturer's identification is permitted on rim of lock cylinders only.

B. Base Metals: Produce door hardware units of base metal indicated, fabricated by forming method indicated, using manufacturer's standard metal alloy, composition, temper, and hardness. Furnish metals of a quality equal to or greater than that of specified door hardware units and BHMA A156.18.

C. Fasteners: Provide door hardware manufactured to comply with published templates prepared for machine, wood, and sheet metal screws. Provide screws that comply with commercially recognized industry standards for application intended, except aluminum fasteners are not permitted. Provide Phillips flat-head screws with finished heads to match surface of door hardware, unless otherwise indicated.

1. Concealed Fasteners: For door hardware units that are exposed when door is closed, except for units already specified with concealed fasteners. Do not use through bolts for installation where bolt head or nut on opposite face is exposed unless it is the only means of securely attaching the door hardware. Where through bolts are used on hollow door and frame construction, provide sleeves for each through bolt.

PROJECT NO. 12-194.45 08 7100 - 10

2. Fire-Rated Applications:

a. Wood or Machine Screws: For the following:

1) Hinges mortised to doors or frames; use threaded-to-the-head wood screws for wood doors and frames.

2) Strike plates to frames.

3) Closers to doors and frames.

b. Steel Through Bolts: For the following unless door blocking is provided:

1) Surface hinges to doors.

2) Closers to doors and frames.

3) Surface-mounted exit devices.

3. Spacers or Sex Bolts: For through bolting of hollow-metal doors.

4. Fasteners for Wood Doors: Comply with requirements in DHI WDHS.2, "Recommended Fasteners for Wood Doors."

5. Gasketing Fasteners: Provide noncorrosive fasteners for exterior applications and elsewhere as indicated.

2.17 FINISHES

A. Provide finishes complying with BHMA A156.18 as indicated in door hardware schedule.

B. Protect mechanical finishes on exposed surfaces from damage by applying a strippable, temporary protective covering before shipping.

PART 3 - EXECUTION

3.1 INSTALLATION

A. Examination: Examine doors and frames, with Installer present, for compliance with requirements for installation tolerances, labeled fire-rated door assembly construction, wall and floor construction, and other conditions affecting performance.

1. Examine roughing-in for electrical power systems to verify actual locations of wiring connections before electrified door hardware installation.

B. Steel Doors and Frames: For surface applied door hardware, drill and tap doors and frames according to

ANSI/SDI A250.6.

C. Wood Doors: Comply with DHI WDHS.5 "Recommended Hardware Reinforcement Locations for Mineral Core Wood Flush Doors."

PROJECT NO. 12-194.45 08 7100 - 11

D. Mounting Heights: Mount door hardware units at heights to comply with the following unless otherwise indicated or required to comply with governing regulations.

1. Standard Steel Doors and Frames: ANSI/SDI A250.8.

2. Wood Doors: DHI WDHS.3, "Recommended Locations for Architectural Hardware for Wood Flush

Doors."

E. Install each door hardware item to comply with manufacturer's written instructions. Where cutting and fitting are required to install door hardware onto or into surfaces that are later to be painted or finished in another way, coordinate removal, storage, and reinstallation of surface protective trim units with finishing work specified in Division 09 Sections. Do not install surface-mounted items until finishes have been completed on substrates involved.

1. Set units level, plumb, and true to line and location. Adjust and reinforce attachment substrates as necessary for proper installation and operation.

2. Drill and countersink units that are not factory prepared for anchorage fasteners. Space fasteners and anchors according to industry standards.

F. Hinges: Install types and in quantities indicated in door hardware schedule but not fewer than the number recommended by manufacturer for application indicated or one hinge for every 30 inches (750 mm) of door height, whichever is more stringent, unless other equivalent means of support for door, such as spring hinges or pivots, are provided.

G. Intermediate Offset Pivots: Where offset pivots are indicated, provide intermediate offset pivots in quantities indicated in door hardware schedule but not fewer than one intermediate offset pivot per door and one additional intermediate offset pivot for every 30 inches (750 mm) of door height greater than 90 inches (2286 mm).

H. Lock Cylinders: Install construction cores to secure building and areas during construction period.

1. Replace construction cores with permanent cores as directed by Owner.

2. Furnish permanent cores to Owner for installation.

I. Key Control System: Tag keys and place them on markers and hooks in key control system cabinet, as determined by final keying schedule.

J. Boxed Power Supplies: Locate power supplies as indicated or, if not indicated, above accessible ceilings or in equipment room. Verify location with Architect.

1. Configuration: Provide least number of power supplies required to adequately serve doors with electrified door hardware.

K. Thresholds: Set thresholds for exterior doors and other doors indicated in full bed of sealant complying with requirements specified in Division 07 Section "Joint Sealants."

L. Stops: Provide floor stops for doors unless wall or other type stops are indicated in door hardware schedule. Do not mount floor stops where they will impede traffic.

PROJECT NO. 12-194.45 08 7100 - 12

M. Perimeter Gasketing: Apply to head and jamb, forming seal between door and frame.

N. Meeting Stile Gasketing: Fasten to meeting stiles, forming seal when doors are closed.

O. Door Bottoms: Apply to bottom of door, forming seal with threshold when door is closed.

3.2 FIELD QUALITY CONTROL

A. Independent Architectural Hardware Consultant: Owner will engage a qualified independent Architectural Hardware Consultant to perform inspections and to prepare inspection reports.

3.3 ADJUSTING

A. Initial Adjustment: Adjust and check each operating item of door hardware and each door to ensure proper operation or function of every unit. Replace units that cannot be adjusted to operate as intended.

Adjust door control devices to compensate for final operation of heating and ventilating equipment and to comply with referenced accessibility requirements.

1. Spring Hinges: Adjust to achieve positive latching when door is allowed to close freely from an open position of 30 degrees.

2. Electric Strikes: Adjust horizontal and vertical alignment of keeper to properly engage lock bolt.

3. Door Closers: Adjust sweep period to comply with accessibility requirements and requirements of authorities having jurisdiction.

B. Occupancy Adjustment: Approximately three months after date of Substantial Completion, Installer's Architectural Hardware Consultant shall examine and readjust each item of door hardware, including adjusting operating forces, as necessary to ensure function of doors, door hardware, and electrified door hardware.

3.4 DEMONSTRATION

A. Engage a factory-authorized service representative to train Owner's maintenance personnel to adjust, operate, and maintain door hardware and door hardware finishes. Refer to Division 01 Section "Demonstration and Training."

3.5 DOOR HARDWARE SCHEDULE

Hardware Group No. 01

3 Hinge 5BB1 4.5 X 4.5 NRP 652 IVE 1 Classroom Lock L9070L 01A 626 SCH 1 Primus Controlled Access Cylinder 20-787 626 SCH 1 Wall Stop WS33 626 IVE

PROJECT NO. 12-194.45 08 7100 - 13

Operational Description

• Latchbolt retracted by knob/lever from either side unless outside is locked by key. Unlocked from out-side by key. Inside knob/lever always free for immediate exit. Auxiliary latch deadlocks latchbolt when door is locked. Inside lever is always free for immediate egress.

Hardware Group No. 02

3 Hinge 5BB1 4.5 X 4.5 NRP 652 IVE 1 Classroom Security L9071L 01A 626 SCH 2 Primus Controlled Access Cylinder 20-787 626 SCH 1 Surface Closer 4040XP 689 LCN 1 Kick Plate 8400 10" X 2" LDW B-CS 630 IVE 1 Wall Stop WS33 626 IVE 1 Gasketing 488S-BK S-Bk ZER

Operational Description

• Latchbolt retracted by knob/lever from either side unless outside is locked by key from either side. Aux-iliary latch deadlocks latchbolt when door is locked. Inside lever is always free for immediate egress.

• Self-Closing.

Hardware Group No. 03

3 Hinge 5BB1 4.5 X 4.5 NRP 652 IVE 1 Storeroom Lock L9080L 01A 626 SCH 1 Primus Controlled Access Cylinder 20-787 626 SCH 1 Surface Closer 4040XP SCUSH 689 LCN 1 Kick Plate 8400 10" X 2" LDW B-CS 630 IVE 1 Gasketing 488S-BK S-Bk ZER

Operational Description

• Latchbolt retracted by key outside or by knob/lever inside. Outside knob/lever always inoperative. Aux-iliary latch deadlocks latchbolt when door is locked. Inside lever is always free for immediate egress.

• Self-Closing. Templating allows Spring CUSH Arm to stop the door's swing between 85 and 110 de-grees.

PROJECT NO. 12-194.45 08 7100 - 14

Hardware Group No. 04

6 Hinge 5BB1 4.5 X 4.5 NRP 652 IVE 1 Auto Flush Bolt Set FB41P 630 IVE 1 Dust Proof Strike DP2 626 IVE 1 Storeroom Lock L9080L 01A 626 SCH 1 Primus Controlled Access Cylinder 20-787 626 SCH 1 Coordinator COR X FL 628 IVE 2 Mounting Bracket MB 689 IVE 2 Surface Closer 4040XP 689 LCN 2 Kick Plate 8400 10" X 1" LDW B-CS 630 IVE 2 Wall Stop WS33 626 IVE

Operational Description

• Latchbolt retracted by key outside or by knob/lever inside. Outside knob/lever always inoperative. Aux-iliary latch deadlocks latchbolt when door is locked. Inside lever is always free for immediate egress.

• Self-Closing.

END OF SECTION 08 7100

VISUAL DISPLAY UNITS

PROJECT NO. 12-194.45 10 1100 - 1

KELLOGSVILLE PUBLIC SCHOOLS ADDENDUM 1 - 01/10/2019

SECTION 10 1100 - VISUAL DISPLAY UNITS

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1. Visual display board assemblies.

1.2 ACTION SUBMITTALS

A. Product Data: For each type of product.

B. Shop Drawings: For visual display units.

1. Include plans, elevations, sections, details, and attachment to other work.

2. Show locations of panel joints

C. Samples for Initial Selection: For each type of visual display unit indicated, for units with factory-applied color finishes, and as follows:

1. Samples of facings for each visual display panel type, indicating color and texture.

2. Include accessory Samples to verify color selected.

D. Samples for Verification: For each type of visual display unit indicated.

1. Visual Display Panel: Not less than 8-1/2 by 11 inches (215 by 280 mm), with facing, core, and backing indicated for final Work. Include one panel for each type, color, and texture required.

E. Product Schedule: For visual display units.

1.3 INFORMATIONAL SUBMITTALS

A. Qualification Data: For Installer.

B. Sample warranties.

1.4 CLOSEOUT SUBMITTALS

A. Maintenance Data: For visual display units to include in maintenance manuals.

PROJECT NO. 12-194.45 10 1100 - 2

1.5 QUALITY ASSURANCE

A. Installer Qualifications: An entity that employs installers and supervisors who are trained and approved by manufacturer.

1.6 FIELD CONDITIONS

A. Environmental Limitations: Do not deliver or install visual display units until spaces are enclosed and weathertight, wet-work in spaces is complete and dry, work above ceilings is complete, and temporary HVAC system is operating and maintaining ambient temperature and humidity conditions at occupancy levels during the remainder of the construction period.

1.7 WARRANTY

A. Special Warranty for Porcelain-Enamel Face Sheets: Manufacturer agrees to repair or replace porcelain-enamel face sheets that fail in materials or workmanship within specified warranty period.

1. Warranty Period: 50 years from date of Substantial Completion.

PART 2 - PRODUCTS

2.1 PERFORMANCE REQUIREMENTS

A. Surface-Burning Characteristics: Comply with ASTM E 84; testing by a qualified testing agency. Identify products with appropriate markings of applicable testing agency.

1. Flame-Spread Index: 25 or less.

2. Smoke-Developed Index: 450 or less.

2.2 VISUAL DISPLAY BOARD ASSEMBLIES

A. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

1. CIG-JAN Products, Ltd.

2. Claridge Products and Equipment, Inc.

3. Marsh Industries, Inc.

4. Platinum Visual Systems.

B. Visual Display Board Assembly:Field or factory fabricated.

1. Assembly: Markerboard.

2. Corners: Square.

3. Width: As indicated on Drawings.

4. Height: As indicated on Drawings.

http://www.specagent.com/Lookup?ulid=9361 http://www.specagent.com/Lookup?uid=123457095875 http://www.specagent.com/Lookup?uid=123457079125 http://www.specagent.com/Lookup?uid=123457079129 http://www.specagent.com/Lookup?uid=123457079132

PROJECT NO. 12-194.45 10 1100 - 3

5. Markerboard Panel: Porcelain-enamel-faced markerboard panel on core indicated.

a. Color: As selected by Architect from full range of industry colors.

C. Aluminum Frames: Fabricated from not less than 0.062-inch- (1.57-mm-) thick, extruded aluminum; slim size and standard shape.

1. Field-Applied Trim: Manufacturer's standard, snap-on trim with no visible screws or exposed joints.

2. Aluminum Finish: Clear anodic finish.

D. Joints: Make joints only where total length exceeds maximum manufactured length. Fabricate with minimum number of joints, balanced around center of board, as acceptable to Architect.

1. Joints between Markerboard Sections: Hidden spline between abutting sections.

E. Chalktray: Manufacturer's standard; continuous.

1. Box Type: Extruded aluminum with slanted front, grooved tray, and cast-aluminum end closures.

2.3 MARKERBOARD PANELS

A. Porcelain-Enamel Markerboard Panels: Balanced, high-pressure, factory-laminated markerboard assembly of three-ply construction, consisting of moisture-barrier backing, core material, and porcelain-enamel face sheet with high-gloss finish. Laminate panels under heat and pressure with manufacturer's standard, flexible waterproof adhesive.

1. Face Sheet Thickness: 0.021 inch (0.53 mm) uncoated base metal thickness.

2. Particleboard Core: 3/8 inch (9.5 mm) thick; with 0.005-inch- (0.127-mm-) thick, aluminum foil backing.

3. Laminating Adhesive: Manufacturer's standard moisture-resistant thermoplastic type.

2.4 MATERIALS

A. Porcelain-Enamel Face Sheet: PEI-1002, with face sheet manufacturer's standard two- or three-coat process.

B. Particleboard: ANSI A208.1, Grade M-1.

C. Extruded Aluminum: ASTM B 221 (ASTM B 221M), Alloy 6063.

2.5 ALUMINUM FINISHES

A. Clear Anodic Finish: AAMA 611, AA-M12C22A31, Class II, 0.010 mm or thicker.

PROJECT NO. 12-194.45 10 1100 - 4

PART 3 - EXECUTION

3.1 INSTALLATION

A. General: Install visual display surfaces in locations and at mounting heights indicated on Drawings, or if not indicated, at heights indicated below. Keep perimeter lines straight, level, and plumb. Provide grounds, clips, backing materials, adhesives, brackets, anchors, trim, and accessories necessary for complete installation.

B. Field-Assembled Visual Display Board Assemblies: Coordinate field-assembled units with grounds, trim, and accessories indicated. Join parts with a neat, precision fit.

1. Make joints only where total length exceeds maximum manufactured length. Fabricate with minimum number of joints, balanced around center of board, as acceptable to Architect.

2. Where size of visual display board assemblies or other conditions require support in addition to normal trim, provide structural supports or modify trim as indicated or as selected by Architect from manufacturer's standard structural support accessories to suit conditions indicated.

C. Factory-Fabricated Visual Display Board Assemblies: Attach concealed clips, hangers, and grounds to wall surfaces and to visual display board assemblies with fasteners at not more than 16 inches (400 mm) o.c. Secure tops and bottoms of boards to walls.

D. Visual Display Board Assembly Mounting Heights: Install visual display units at mounting heights indicated on Drawings, or if not indicated, at 36 inches (914 mm) above finished floor to top of chalktray.

3.2 CLEANING AND PROTECTION

A. Clean visual display units in accordance with manufacturer's written instructions. Attach one removable cleaning instructions label to visual display unit in each room.

B. Touch up factory-applied finishes to restore damaged or soiled areas.

C. Cover and protect visual display units after installation and cleaning.

END OF SECTION 10 1100

DN

1 HR

HR

1 HR

OFFICE

MEDIA CENTER

CORRIDOR

STORAGE

OFFICE

E G

R E

S S

C L A

S S

R O

O M

E

G R

E S

S

S T

O R

A G

E

116A

115A

TRAVEL D

IS

TANCE 5

4 F

EET

75 F

EET P

ERM

IT

TED

TRAVEL DISTANCE 142 FEET

200 FEET PERMITTED

TRAVEL DISTANCE 39 FEET

75 FEET PERMITTED

E G

R E

S S

M E

D

IA

C E

N T

E R

CLASSROOM

TRAVEL DISTANCE 39 FEET

75 FEET PERMITTED

116B

115B

XFE

FE

A1

A1

FIRE-RATING KEY & SYMBOLS

DESIGNATION PARTITION RATING

2 HOUR FIREWALL PROVIDE FROM FLOOR TO UNDERSIDE OF ROOF DECK ABOVE.

CONSTRUCTION SHALL BE CONTINUOUS THROUGH CEILING CAVITIES.

WALL SHALL ALLOW STRUCTURAL COLLAPSE ON EITHER SIDE OF WALL

UNDER FIRE CONDITIONS WITHOUT DAMAGE TO WALL. PROVIDE WITH

90-MINUTE LABELED DOORS W/ CLOSER

1HOUR PROVIDE FROM FLOOR TO UNDERSIDE OF FLOOR OR ROOF DECK

ABOVE. CONSTRUCTION SHALL BE CONTINUOUS THROUGH CEILING

CAVITIES. AT PENETRATIONS THROUGH PARTITION, SEAL OPENINGS

AROUND HVAC, FIRE PROTECTION, PLUMBING, & ELECTRICAL

PENETRATIONS WITH FIRESTOPPING. PROVIDE WITH 45-MINUTE LABELED

DOORS W/ CLOSER EXCEPT PROVIDE 60-MINUTE LABEL FOR STAIR

DOORS.

EGRESS

ROOM

OCCUPANTS

EXIT NUMBER FROM ROOM OR SPACE

MAXIMUM NUMBER OF OCCUPANTS THE EGRESS WIDTH WILL ALLOW

ROOM OR SPACE EGRESS IS FROM

EXISTING FIRE EXTINGUISHERXFE

FIRE EXTINGUISHER: PROVIDE MULTIPURPOSE 10LBS. CLASS 4.A:60BC ON HANGER AT 48” AFF

FIRE CODE SYMBOLS

FE

FW

A1

2015 Michigan Building Code:

2015 Michigan Building Code

Section 305 E Group, Type IIB Construction

Table 504.3 Allowable Building Height in Feet Above Gade Plane

E Group, Type IIB Construction, Non-Sprinkled = 55ft.

Table 506.2 Allowable Area Factor in Square Feet

E Group, Type IIB Construction, Non-Sprinkled = 14,500 sq. ft.

Total Building Area: 32,622 Square Feet

1,964 Square Feet - First Floor Renovation

588 Square Feet - First Floor Storage Room Renovation

30,070 Square Feet - First Floor Existing

Table 601

Construction Type: IIB

Structural Framing Members = 0 Hr fire rating

Bearing Walls (Ext.) = 0 Hr fire rating

Bearing Walls (Int.) = 0 Hr fire rating

Nonbearing walls and partitions (Ext. and Int.) = 0 Hr fire rating

Floor Construction = 0 Hr fire rating

Roof Construction = 0 Hr fire rating

Table 602.1

Type IIB - Construction that is that type of construction in which the building elements listed in table 601 are of noncombustible materials, except as permitted in section 603 and elsewhere in this code.

Section 706.4 - Fire walls are not required for this project as the building floor area does not exceed the maximum allowed.

Section 707.3.10 Fire Areas. The fire barriers or horizontal assemblies, or both, separating a single occupancy into different fire areas shall have a fire-resistance rating of not less than that indicated in Table 707.3.10. The fire barriers or horizontal assemblies, or both, separating fire areas of mixed occupancies shall have a fire-resistance rating of not less than the highest value indicated in Table 707.3.10 for the occupancies under construction.

Section 708.3 Fire-resistance ratings. Fire partitions shall have a fire-resistance rating of not less than 1 hour.

Section 803 – Interior Finishes

Table 803.9

Use Group E, (not sprinkled)

Exit Enclosures and Exit Passageways = A

Corridors = B

Rooms and Enclosed Spaces = C

Section 906 – Portable Fire Extinguishers. Portable fire extinguishers shall be installed in the following locations: Table 906.3 Maximum Travel Distance to Fire Extinguisher 75 feet.

1. In existing R-2 occupancy

2. Within 30 feet of commercial cooking equipment

3. In areas with flammable or combustible liquids

4. On each floor of structures under construction

5. Where required by the International Fire Code Sections indicated in Table 906.1

6. Special-Hazard areas

Section 1004.1 Occupant Load. In determining the means of egress requirements, the number of occupants for whom means of egress facilities shall be provided shall be established by the largest number computed in accordance with Sections 1004.1.1 through

1004.1.3.

Table 1004.1.2 Maximum Floor Area Allowances per Occupant

Accessory Storage / Mechanical Equip. Rooms 300 gross

Educational - Shops and other vocational room areas 50 net

Business Areas 100 gross

Section 1005 Minimum Required Egress Width. The means of egress width shall not be less than required by this section.

An Occupancy with Sprinkler System Stairway means of egress = 0.2

An Occupancy with Sprinkler System all other means of egress = 0.2

Table 1006.2.1 Spaces With One Exit or Exit Access Doorway

Group E, Without Sprinkler System = 75 Feet

Section 1015.2.1 Where two exits or exit access doorways are required from any portions of the exit access, the exit doors or exit access doorways shall be placed a distance apart equal to not less than one-half the diagonal distance of the space.

Table 1017.2 Exit Access Travel Distance: Group E Without Sprinkler = 200 Feet

Tower Pinkster Titus Associates Inc.

242 East Kalamazoo Avenue, Suite 200

Kalamazoo, Michigan 49007-5828

269.343.6133 PHONE 269.343.6633 FAX

TOWERPINKSTER.COM

ALL RIGHTS RESERVED2019©

DATE

PROJECT TITLE

SHEET TITLE

SHEET NUMBER

4 East Fulton Street, Suite 200

Grand Rapids, Michigan 49503

616.456.9944 PHONE 616.456.5936 FAX

JANUARY 10, 2019

WEST

ELEMENTARY

MEDIA CENTER

RENOVATION

Grand Rapids, Michigan

OVERALL CODE

COMPLIANCE

PLAN

12-194.45

G 101

KELLOGGSVILLE

PUBLIC

SCHOOLS

3/32" = 1'-0"

OVERALL FIRST FLOOR CODE COMPLIANCE PLAN

ISSUED FOR DATE

ADDENDUM 1 JANUARY 30, 2019

DN

DN

CORRIDOR

MEDIA CENTER

1 HR

HR

OFFICE

STORAGE

A 201

20' - 0" V.I.F.

116A

A 601

6' - 0"

3K

3K

A 201

3K

KNOX BOX LOCATION

OFFICE

NEW BORROWED LITES -

TOOTH-IN DOUBLE BULLNOSE

CMU AT ALL WINDOW JAMBS.

CENTER BORROWED LITE IN WALL

6' - 8" 2' - 0" 4' - 0" 2' - 0" 4' - 0"

115A

1G

A 201

2' - 8"

CLASSROOM

116B

1G 1G2B

" 2' - 8"

COMPUTER

LAB

WORK ROOM

OFFICE

OPEN OFFICE

TOILET

TLT

SECURE

VESTIBULE

CONFERENCE

TEACHERS

GYMNASIUM

TOILET

CLOSET

CLOSET

NEW ENTRY CANOPY

40' - 0 1/4"

115B

ALIGN WALL WITH EDGE

OF WINDOW OPENING

V .I .F

1G

37' - 8 1/4" V.I.F.

/8

/8

2B

3G

3G

3G

11' - 11 5/8" 13' - 9" 11' - 11 5/8"

A 201 5

OFFICE

OPEN OFFICE

WORK ROOM

CLASSROOM

TLT

TLT

TLTSTO

SECURE

VESTIBULE

CORRIDOR

MEDIA CENTER

VEST.

OFFICE

OFFICE

2 2

3 3

STAGE

STORAGE

14 13

GYMNASIUM

CONFERENCE

TEACHERS LOUNGE

WORK ROOM

WOMEN

J.C.

MEN

/8

V .I .F

/8

/8 "3

/8

3' - 6 7/8" 6' - 8" 2' - 0" 6' - 0" 4' - 0"

A1

A 201

A1

Tower Pinkster Titus Associates Inc.

242 East Kalamazoo Avenue, Suite 200

Kalamazoo, Michigan 49007-5828

269.343.6133 PHONE 269.343.6633 FAX

TOWERPINKSTER.COM

ALL RIGHTS RESERVED2019©

DATE

PROJECT TITLE

SHEET TITLE

SHEET NUMBER

4 East Fulton Street, Suite 200

Grand Rapids, Michigan 49503

616.456.9944 PHONE 616.456.5936 FAX

JANUARY 10, 2019

WEST

ELEMENTARY

MEDIA CENTER

RENOVATION

Grand Rapids, Michigan

DEMOLITION &

FLOOR PLANS

12-194.45

A 101

KELLOGGSVILLE

PUBLIC

SCHOOLS

1/8" = 1'-0"

FLOOR PLAN

1/8" = 1'-0"

DEMOLITION PLAN

WEST ELEMENTARY

KEY PLAN

SCALE: NO SCALE

0'

5'

10'

15' 25'

1/8" = 1'-0" GRAPHIC SCALE

RENOVATION

AREAS

NOTES:

1. SEE A600 SERIES SHEETS FOR INTERIOR ELEVATION REFERENCES AND

WINDOW TREATMENTS

2. SEE SHEET G 003 FOR WALL TYPE LEGEND

3. SEE ENLARGED PLAN (A-501) FOR ADDITIONAL DIMENSIONS

4. 100'- 0" = 681.10' SEE CIVIL DRAWINGS

KEYED NOTES - DEMOLITION

1 REMOVE DOOR, FRAME, AND ASSOCIATED HARDWARE

2 REMOVE FLOORING AND BASE - PREP FOR NEW WORK

3 REMOVE CEILING TILE AND GRID

6 REMOVE PLUMBING FIXTURE / MECHANICAL EQUIPMENT. COORDINATE WITH MECH/

PLUMBING DRAWINGS

7 REMOVE WALL AND DOOR SYSTEM - TURN WALL PANELS OVER TO OWNER

8 REMOVE BOOK SHELVING UNITS. TURN OVER TO OWNER

9 REMOVE WOOD PROSCENIUM WALL CONSRUCTION (ABOVE & BELOW) STAGE LIGHTING

AND CURTAIN

10 REMOVE RAISED WOOD FLOOR CONSTRUCTION DOWN TO GYM FLOOR SLAB

INCLUDING CHAIR STORAGE UNITS BELOW

11 REMOVE STAIR CONSTRUCTION

12 REMOVE MEZZANINE WOOD FLOOR CONSTRUCTION

13 REMOVE WALL

14 REMOVE CASEWORK - SALVAGE FOR OWNER REUSE

17 REMOVE RADIANT PANEL CEILING SYSTEM AND RELATED - REFER TO MECHANICAL

18 REMOVE EXISTING PORTION OF MASONRY WALL FOR NEW OPENING

KEYED NOTES - NEW CONSTRUCTION

1 6'-0" TACK BOARD (4'-0" TALL AT 2'-6" A.F.F.)

2 12'-0" MARKER BOARD (4'-0" TALL AT 2'-6" A.F.F.)

3 REROUTE SOUND SYSTEM WIRING - WORK TO BE COORDINATED WITH OWNER

ISSUED FOR DATE

NOTE #4 REMOVED

F

WAP

WAP

WAP

WAP

OFFICE

MEDIA CENTER

ACP-1

9' - 8"

OFFICE

ACP-1

10' - 0"

ACP-1

9' - 8"

CLASSROOM

ACP-1

9' - 0"

P-3 9' - 0"

P-3 9' - 0"

P-3 9' - 0"

GYPSUM BOARD

LAY-IN ACOUSTICAL TILE GRID

OR LIGHTING - REFER TO ELECTRICAL LIGHTING PLAN

MECHANICAL - REFER TO MECHANICAL SHEET METAL PLAN

REFLECTED CEILING KEY

6" RIGID INSULATION ON SLOPED METAL ROOF DECK.

COORDINATE BEARING HEIGHTS WITH STRUCTURAL DRAWINGS

ROOF PLAN KEY

TAPERED INSULATION

R.D.

O.D.

ROOF SLOPE DUE TO TAPERED INSULATION OR

SLOPED STRUCTURE - REFER TO STRUCTURAL DRAWINGS

AHU OR RTU

ACCU

E.F.

ROOF DRAIN - SEE PLUMBING DRAWINGS

OVERFLOW DRAIN - SEE PLUMBINMG DRAWINGS

ROOF TOP UNIT - SEE MECHANICAL DAWINGS

CONDENSING UNIT - SEE MECHANICAL DRAWINGS

EXHAUST FAN / HOOD - SEE MECHANICAL DRAWINGS

1. TYPICAL ROOF SLOPE 1/4" / 1'-0" UNLESS NOTED OTHERWISE.

2. PROVIDE ROOFING MANUFACTURERS STANDARD ROOFING TERMINATION

DETAILS AT ALL PARAPETS, GRAVEL STOPS, CURBS, PIPE PENETRATIONS, ETC.

3. PROVIDE CRICKETS AS REQUIRED AT ALL MECHANICAL UNITS, VENTS,

ETC. TO MAINTAIN POSITIVE SLOPE OF 1/4" /1'-0" MINIMUM.

ROOF NOTES

FIRST FLOOR

100' - 0"

TOM - LOW

112' - 8"

A 201

CANOPY WITH STANDING SEAM METAL ROOF

INTEGRATED GUTTER &

DOWNSPOUTS

KNOX BOX

1' - 0"

V.I.F.

9' - 10" 1' - 0"

EXTERIOR ELEVATION KEY

CJ = CONTROL JOINT, COLOR: MATCH FACEBRICK

STANDING SEAM METAL ROOF, COLOR: SILVERSMITH

FIRST FLOOR

100' - 0"

TOM - LOW

112' - 8"

A 201

8' - 0"

/4

DOWNSPOUT, EACH SIDE OF

CANOPY. FINISH TO MATCH

FASCIA. SEE ELEVATION

VERIFY IN FIELD

TOM - LOW

112' - 8"

STANDING SEAM METAL ROOF

FLASHING UP TO EXISTING ROOF/TOP

OF WALL. 2'-0" MINIMUM OVERLAP

OVER EXISTING ROOF

EXISTING CONSTRUCTION

3' - 10 5/8"3' - 6" V.I.F. 1 7/8"

/4

/2

3 1/2"

8' - 0"

20ga. STEEL STUDS AT 16" O.C.

1-1/2" METAL ROOF DECK

DIRECT APPLIED FINISH SYSTEM (D.F.S.)

ON 1 1/2" INSULATION ON 1/2" EXTERIOR

GRADE GYP. BOARD AT CANOPY SOFFIT.

8" METAL STUDS AT 16" O.C.

GUTTER INTEGRATED IN ROOF EDGE.

SLOPE FROM CENTER OF CANOPY

WIDTH TO DOWNSPOUTS

FASCIA WRAPPED WITH BREAK

METAL TO MATCH ROOF COLOR

2X BLOCKING AS REQUIRED

(3) LAYERS OF 5/8" PLYWOOD SHEATHING

W14x34 STEEL BEAM BEARING 8" ONTO EXISTING CMU

WALL CONSTRUCTION. GROUT SOLID AND ANCHOR TO

EXISTING WALL. VERIFY IN FIELD EXISTING CONDITIONS

W8X10 BEAMS BEARING 8" ONTO EXISTING

CMU WALL CONSTRUCTION. GROUT SOLID

AND ANCHOR TO EXISTING WALL. VERIFY IN

FIELD EXISTING CONDITIONS

C6X13 CHANNEL STEEL AT (3) LOCATIONS. WELD TO W8X10 STEEL BEAMS

STUD CLIP AT STEEL BEAM

SEE SCHED.

S

EE

S C H

ED

U

LE

F

SEE SCHED.

S

EE

S C H

ED

U

LE

G

8" 8"

SEE SCHED. 2"2"

SEE SCHED. 2"2"

S

EE

S C H

ED

U

LE

S

EE

S C H

ED

U

LE

SEE PLAN

CMU - SEE

PLANS

(2) L5x3-1/2x5/16 LINTEL

BEARING 8" EACH END (NO

BEARING PLATES REQUIRED)

HOLLOW METAL

FRAME - SEE

SCHEDULE

PAINT - TYP.

SEALANT AT

PERIMETER,

BOTH SIDES

5/8" GYP. BD.

ON FURRING,

SEE PLANS FOR

LOCATIONS

A1

ALT. WALL

LOCATION SEE

FLOOR PLANS

CMU WALL, SEE

FLOOR PLANS

BULLNOSE

SEALANT AT

PERIMETER,

BOTH SIDES

HOLLOW METAL

FRAME - SEE

SCHEDULE -

GROUT SOLID

WITH 3 TIES

PER JAMB

FRAME RETURN TO

BE PAINTED FRAME

COLOR - NOT

WALL COLOR, TYP.

ALL FRAMES

5/8" GYP. BD.

ON FURRING,

SEE PLANS FOR

LOCATIONS

A 201

EXISTING ENTRY WALL

OUTLINE OF ROOF ABOVE

(3) C6X13 CHANNEL STEEL

AT MID AND END

LOCATIONS OF CANOPY

EQ

EQ

W8X10 BEAMS BEARING 8" ONTO

EXISTING CMU WALL

CONSTRUCTION. GROUT SOLID AND

ANCHOR TO EXISTING WALL. VERIFY

IN FIELD EXISTING CONDITIONS

W14x34 STEEL BEAM

BEARING 8" ONTO EXISTING

CMU WALL CONSTRUCTION.

GROUT SOLID AND ANCHOR

TO EXISTING WALL. VERIFY IN

FIELD EXISTING CONDITIONS

V .I .F

SEE PLAN

2" TYP.

EXISTING GYPSUM BOARD

INFILL WALL, VERIFY IN FIELD

EQ. EQ. EQ.

SEE PLAN

EQ. EQ.1' - 9" 1' - 9"

TY

P

S-1

A 201

Sim

S-2

A 201

Sim

A1

2' - 0" SEE PLAN 6' - 0" SEE PLAN

EQ. EQ. EQ. EQ. EQ. EQ.

2" TYP.

TY

P

EXISTING WALL RECESS

S-2

A 201

Sim

S-1

A 201

Sim

A1

HOLLOW METAL

FRAME - SEE

SCHEDULE SEALANT AT

PERIMETER,

BOTH SIDES

BULLNOSE, TYP.

EXISTING WALL

CONSTRUCTION

SEE PLAN

HOLLOW METAL FRAME -

SEE SCHEDULE

SEALANT AT

PERIMETER,

BOTH SIDES

BULLNOSE, TYP.

EXISTING WALL

CONSTRUCTION

SEE PLAN

1/2" SOLID SURFACE

(SSM-1) OVER 1/2"

PLYWOOD. PROVIDE 1-1/2"

BUILT-UP FRONT EDGE

WITH 1/4" RADIUS

1"

FIRST FLOOR

100' - 0"

TOM - LOW

112' - 8"

V.I.F.

9' - 10"

REMOVE EXISTING EIFS FASCIA AND

SOFFIT BACK TO BRICK PIERS

BRICK PIERBRICK PIER

Tower Pinkster Titus Associates Inc.

242 East Kalamazoo Avenue, Suite 200

Kalamazoo, Michigan 49007-5828

269.343.6133 PHONE 269.343.6633 FAX

TOWERPINKSTER.COM

ALL RIGHTS RESERVED2019©

DATE

PROJECT TITLE

SHEET TITLE

SHEET NUMBER

4 East Fulton Street, Suite 200

Grand Rapids, Michigan 49503

616.456.9944 PHONE 616.456.5936 FAX

JANUARY 10, 2019

WEST

ELEMENTARY

MEDIA CENTER

RENOVATION

Grand Rapids, Michigan

REFLECTED

CEILING, ROOF

PLAN, DOOR

SCHEDULE,

DOOR AND

FRAME TYPES

12-194.45

A 201

KELLOGGSVILLE

PUBLIC

SCHOOLS

1/8" = 1'-0"

REFLECTED CEILING PLAN

WEST ELEMENTARY

KEY PLAN

SCALE: NO SCALE

0'

5'

10'

15' 25'

1/8" = 1'-0" GRAPHIC SCALE

RENOVATION

AREAS

1/8" = 1'-0"A 201

1 EAST ELEVATION - CANOPY

1/2" = 1'-0"A 201

2 ENTRY CANOPY SECTION

1" = 1'-0"A 201

3 ENTRY CANOPY DETAIL

DOOR SCHEDULE - FIRST FLOOR

NUMBER

ROOM

NAME

FIRE-RATING DOOR SIZE FRAME DETAILS

GLASS

ACCESS CONTROLS

HDWR.

SET REMARKSDOOR ROOM DOOR FRAME TYPE MAT FIN WIDTH HEIGHT ELEV MAT FIN HEAD JAMB SILL

BARRIER-

FREE

CARD

READER

112 112 MEDIA CENTER 45 MIN 45 MIN G WD PREFIN 3' - 0" 7' - 2" 1 HM REFER TO

FINISH PLAN

H-1 J-1 - 45 MIN No No 02 -

115A 115 CLASSROOM 45 MIN 45 MIN G WD PREFIN 3' - 0" 7' - 2" 1 HM REFER TO

FINISH PLAN

H-1 J-1 - 45 MIN No No 02 -

115B 115 CLASSROOM - - G WD PREFIN 3' - 0" 7' - 2" 1 HM REFER TO

FINISH PLAN

- - - - No No 01 -

116A 116 STORAGE 45 MIN 45 MIN F WD PREFIN 3' - 0" 7' - 2" 1 HM REFER TO

FINISH PLAN

H-1 J-1 - - No No 03 -

116B 116 STORAGE - - F WD PREFIN 6' - 0" 7' - 2" 2 HM REFER TO

FINISH PLAN

H-1 J-1 - - No No 04 -

1/4" = 1'-0"

DOOR TYPES

1/4" = 1'-0"

FRAME ELEVATIONS

1 1/2" = 1'-0"A 201

H-1 HEAD DETAIL - H.M. FRAME IN CMU

1 1/2" = 1'-0"A 201

J-1 JAMB DETAIL - H.M. FRAME IN CMU

1/4" = 1'-0"

ENTRY CANOPY ROOF PLAN

1/4" = 1'-0"A 201

4 BORROWED LITE ELEVATION

ISSUED FOR DATE

ADDENDUM 1 JANUARY 30, 2019

1/4" = 1'-0"A 201

5 BORROWED LITE ELEVATION

1 1/2" = 1'-0"A 201

S-1 BORROWED LITE SILL DETAIL

1 1/2" = 1'-0"A 201

S-2 BORROWED LITE SILL DETAIL

A1

A1

1/8" = 1'-0"A 201

6 EAST ELEVATION - DEMO EXISTING CANOPY

A1

FINISH KEY

P-1

VCT CPT

WALL FINISH

FLOOR BASE

FLOOR FINISH

COUNTER FINISH

CABINET FINISH (BASE AND UPPER)

INDICATES EXTENT OF ATYPICAL FINISH

INDICATES FLOOR MATERIAL TRANSITION

NOTE - REFER TO MATERIAL SELECTION SCHEDULE

REMARKS FOR FLOOR TRANSITION TYPE

P-1

RB-1

CPT-1

PL-1

PL-1

REFER TO MATERIAL SELECTION

SCHEDULE FOR FINISH INFORMATION

OFFICE

MEDIA CENTER

STORAGE

GYMNASIUM

P-1

RB-1

CPTL-P

P-1

RB-1

CPTL-13

P-1

RB-1

CPTL-13

E X C

P T

C P T L

EX. CPT CPTL

P-1

RB-2

SC

EX. CPT SC

A 601

P-1

RB-2

S C

E X V C

T

R…

This is the start of the file's text. The full file is on GovTribe.