This is a set of construction drawings for concrete channel repairs at Halls Bayou (Project P118-09-00-X014) prepared for the Harris County Flood Control District (HCFCD) in Houston, Texas. The project involves repairing approximately 2,800 linear feet of concrete-lined channel from Station 12+00 to Station 39+62, with work including removal and disposal of existing concrete channel lining (3,513 square yards), riprap (2,151 square yards), and concrete bottoms, followed by installation of 8-inch nominal thickness concrete channel lining (5,340 square yards) and riprap gradation No. 2 (1,176 square yards). The construction scope encompasses site preparation, clearing and grubbing, excavation and fill operations (totaling 2,681 cubic yards of cut and 564 cubic yards of fill), installation of five cast-in-place headwall and wingwall structures at existing culvert locations, storm sewer pipe installation (18-inch, 30-inch, and 36-inch reinforced concrete pipe), geotextile filter material, turf establishment through sodding and hydromulch seeding, stormwater pollution prevention measures, and temporary erosion control features. The project requires adherence to Harris County Flood Control specifications and includes provisions for utility coordination with CenterPoint Energy, AT&T, Magellan Pipeline Company, and other existing underground and overhead facilities.

The 42-sheet drawing set includes plan and profile views, cross-sections, typical details for channel lining and riprap placement, culvert structure details with reinforcement specifications, and stormwater pollution prevention plan details. Key design specifications call for Class C concrete with minimum 3,600 PSI compressive strength, Grade 60 reinforcing steel, and riprap installation per HCFCD standards. The project incorporates best management practices for construction sequencing, including limiting channel disturbance to maximum 1,500 linear foot segments and establishing completed sections for revegetation. Construction access is provided at three locations (Bigwood Street, Parker Road, and Gleason Road) with temporary access easements and stabilized construction access points. Environmental considerations include tree and plant protection zones, migratory bird nest habitat surveys, and wetland protection measures. The drawings reference geotechnical recommendations from a September 2025 addendum report prepared by Cibor Geoconsultants and specify compliance with Texas Pollution Discharge Elimination System (TPDES) general permit requirements under the Clean Water Act.

View the file

Other files

Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VICINITY MAP

PCT 1

KEY MAP PG. 455A, 415W

11750 Katy Freeway Suite 1260

800.414.1045 Houston, TX 77079

PLAN SET PREPARED BY:

LOCATION MAP

N.T.S.

P118-09-00-E009

COUNTY JUDGE LINA HIDALGO

EXECUTIVE DIRECTOR CHRISTINA (TINA) PETERSEN, PHD, P.E.

PCT. 1 RODNEY ELLIS

PCT. 2 ADRIAN GARCIA

PCT. 3 TOM S. RAMSEY, P.E.

PCT. 4 LESLEY BRIONES

PROJECT

LOCATION

HCFCD PROJECT ID# P118-09-00-X014

CONCRETE CHANNEL REPAIR

HCFCD UNIT# P118-09-00

P:

\2

3\

.0 1_

CO

H

CO

NC

RE

TE

L

IN

IN

G\

DR

AW

IN

GS

\S

HE

ET

S\

1_

CO

VE

R

SH

EE

T.

DW

G

S

.B

HU

SA

L |

S

AV

ED

: T hu rs da y, Fe br ua ry

9, :2 3:

A

M

H

CF

CD

_1

1X

_N

CS

F

IN

AL

.C

TB |

P

LO

TT

ED

: Th ur sd ay , F eb ru ar y 1

9, :2

9:

A M

N

N

HALLS BAYOU

(P118-00-00)

ST

ATE OF TEXAS

PROFESS IONAL ENGIN

EE

RL I CENSED

Issued for Bidding Job 26-0093

Houston, Texas 77092 9900 Northwest Freeway

SHEET NUMBER

DATE:

PR

EP

AR

ED

C H

EC

KE

D

AP

PR

O

VE

D

OF

C H

EC

KE

D

AP

PR

O

VE

D

R

EV

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

ST

ATE OF TEXAS

PROFESS IONAL ENGIN

EE

RL I CENSED

H C

FC

D

P R

O

JE

C T

ID

P1

-0 9-

-X

C O

N C

R

ET

E C

H

AN

N

EL

R

EP

AI

R

H C

FC

D

U N

IT

P1

-0 9-

11750 Katy Freeway, Suite 1260 Houston, TX 77079

800.414.1045

P:

\2

3\

.0 1_

CO

H

CO

NC

RE

TE

L

IN

IN

G\

DR

AW

IN

GS

\S

HE

ET

S\

2_

IN

DE

X

OF

D

RA

W

IN

GS

.D

W G

S

AV

ED

: M on da y, Fe br ua ry

3, :3 8:

A

M

P

LO

TT

ED

: M on da y, Fe br ua ry

3, :4 2:

A

M

SCALE:

D R

AW

IN

G

IN

D

EX

A N

D Q

U

AN

TI

TY

T

AB

LE

SB PG N

W

FEB. 2026

NONE

2 42

INDEX OF SHEETS

SHEET TITLE REV. DATE

1 COVER SHEET

2 DRAWING INDEX AND QUANTITY TABLE

3 GENERAL NOTES (1 OF 2)

4 GENERAL NOTES (2 OF 2)

5 PROJECT LEGEND AND ABBREVIATIONS

6 SURVEY CONTROL LAYOUT PLAN

7 PROJECT LAYOUT PLAN

8 CLEARING, GRUBBING & DEMO PLAN (1 OF 2)

9 CLEARING, GRUBBING & DEMO PLAN (2 OF 2)

10 ACCESS PLAN

11 STORMWATER POLLUTION PREVENTION PLAN (1 OF 2)

12 STORMWATER POLLUTION PREVENTION PLAN (2 OF 2)

13 TYPICAL SECTIONS

14 PLAN & PROFILE (1 OF 6)

15 PLAN & PROFILE (2 OF 6)

16 PLAN & PROFILE (3 OF 6)

17 PLAN & PROFILE (4 OF 6)

18 PLAN & PROFILE (5 OF 6)

19 PLAN & PROFILE (6 OF 6)

20 EARTHWORK CROSS SECTIONS (1 OF 14)

21 EARTHWORK CROSS SECTIONS (2 OF 14)

22 EARTHWORK CROSS SECTIONS (3 OF 14)

23 EARTHWORK CROSS SECTIONS (4 OF 14)

24 EARTHWORK CROSS SECTIONS (5 OF 14)

25 EARTHWORK CROSS SECTIONS (6 OF 14)

26 EARTHWORK CROSS SECTIONS (7 OF 14)

27 EARTHWORK CROSS SECTIONS (8 OF 14)

28 EARTHWORK CROSS SECTIONS (9 OF 14)

29 EARTHWORK CROSS SECTIONS (10 OF 14)

30 EARTHWORK CROSS SECTIONS (11 OF 14)

31 EARTHWORK CROSS SECTIONS (12 OF 14)

32 EARTHWORK CROSS SECTIONS (13 OF 14)

33 EARTHWORK CROSS SECTIONS (14 OF 14)

34 STORM SEWER AND RIPRAP DETAILS

35 CONCRETE CHANNEL LINING DETAILS

36 CHANNEL LINING SECTION DETAIL

P118-09-00-X014 QUANTITY TABLE

CONCRETE CHANNEL REPAIR STATE CHANNEL REACH

PAY ITEM # SHORT DESCRIPTION UNIT QUANTITY

1531-03 PROVIDE & INSTALL TEMPORARY ACCESS MATS LS 1

1555-03 TRAFFIC CONTROL AND REGULATION LS 1

1562-01 CONSTRUCTION FENCE LF 1000

2120-02 DEBRIS AND TRASH REMOVAL AND DISPOSAL IN A LANDFILL CY 100

2120-04 REMOVE & DISPOSE OF ALL PIPE LF 48

2120-05 REMOVE & DISPOSE OF CONCRETE CHANNEL LINING SY 3513

2120-11 REMOVE & DISPOSE OF RIPRAP SY 2151

2120-68 REMOVE AND DISPOSE OF CHAIN LINK FENCE LF 65

2200-12

SITE PREPARATION & RESTORATION, INCLUDING CLEARING &

GRUBBING, CARE AND CONTROL OF WATER, TREE & PLANT

PROTECTION AND FACILITY FOR ENGINEER

LS 1

2223-01 CUT AND PLUG WATER MAIN EA 6

2315-02 EXCAVATION & OFF-SITE DISPOSAL CY 3330

2315-03 EXCAVATION & FILL (ON-SITE MATERIAL) CY 828

2315-04 IMPORTED FILL CY 85

2322-01 FLOWABLE CONCRETE FILL (2,500 PSI) CY 16

2361-02 REINFORCED SILT FENCE LF 500

2362-01 CONCRETE TRUCK WASHOUT STRUCTURES EA 5

2364-02 FILTER DAM - TYPE 2 LF 40

2365-01 STABILIZED CONSTRUCTION ACCESS SY 675

2366-01 INLET PROTECTION BARRIER EA 2

2376-04 CONCRETE CHANNEL LINING, 8" NOMINAL THICKNESS SY 5340

2378-03 RIPRAP,GRADATION NO. 2 SY 1176

2379-01 GEOTEXTILE FILTER MATERIAL FOR RIPRAP SY 1176

2558-02

TELEVISION INSPECTION OF EXISTING GRAVITY SANITARY

SEWER (REFERENCE TO COH UNIT PRICE NO. 2531-400) LF 200

2611-01 18-INCH REINFORCED CONCRETE PIPE LF 32

2611-03 30-INCH REINFORCED CONCRETE PIPE LF 8

2611-04 36-INCH REINFORCED CONCRETE PIPE LF 8

2632-72 HEADWALLS AND WINGWALLS (CAST-IN-PLACE);

STRUCTURE NO. 1 EA 1

2632-72 HEADWALLS AND WINGWALLS (CAST-IN-PLACE);

STRUCTURE NO. 2 EA 1

2632-72 HEADWALLS AND WINGWALLS (CAST-IN-PLACE);

STRUCTURE NO. 3 EA 1

2632-72 HEADWALLS AND WINGWALLS (CAST-IN-PLACE);

STRUCTURE NO. 4 EA 1

2632-72 HEADWALLS AND WINGWALLS (CAST-IN-PLACE);

STRUCTURE NO. 5 EA 1

2820-08 6' CHAIN LINK FENCE LF 65

2849-06 TYPE III TRAFFIC BARRIER (TEMPORARY) EA 5

2921-04 TURF ESTABLISHMENT - SODDING SY 5120

2928-02 HYDROMULCH TURFGRASS SEEDING SY 5120

0001-99 CONTINGENCY DO 1

CULVERT STRUCTURE DETAILS (1 OF 5)

CULVERT STRUCTURE DETAILS (2 OF 5)

CULVERT STRUCTURE DETAILS (3 OF 5)

CULVERT STRUCTURE DETAILS (4 OF 5)

CULVERT STRUCTURE DETAILS (5 OF 5)

STORMWATER POLLUTION PREVENTION DETAILS

SHEET NUMBER

DATE:

PR

EP

AR

ED

C H

EC

KE

D

AP

PR

O

VE

D

OF

C H

EC

KE

D

AP

PR

O

VE

D

R

EV

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

ST

ATE OF TEXAS

PROFESS IONAL ENGIN

EE

RL I CENSED

H C

FC

D

P R

O

JE

C T

ID

P1

-0 9-

-X

C O

N C

R

ET

E C

H

AN

N

EL

R

EP

AI

R

H C

FC

D

U N

IT

P1

-0 9-

11750 Katy Freeway, Suite 1260 Houston, TX 77079

800.414.1045

P:

\2

3\

.0 1_

CO

H

CO

NC

RE

TE

L

IN

IN

G\

DR

AW

IN

GS

\S

HE

ET

S\

5_

GE

NE

RA

L

NO

TE

S (1

O F

2) .D

W G

S

AV

ED

: M on da y, Ja nu ar y 1

2, :3

8:

A M

H

CF

CD

_1 1X

_N

CS

F

IN

AL

LO

TT

ED

: Th ur sd ay , F eb ru ar y 1

9, :2

9:

A M

SCALE:

G

EN

ER

AL

N O

TE

S

(1 O

F 2)

SB PG N

W

FEB. 2026

AS SHOWN

3 42

TXDOT AND HCTRA FACILITIES

BRIDGES CROSSING GREENS BAYOU AT ALDINE BENDER AND BW8 FRONTAGE ROADS ARE MAINTAINED BY TXDOT.

BW8 MAINLANES ARE MAINTAINED BY HCTRA. NO WORK WILL BE PERFORMED WITHIN 50' FROM THESE BRIDGES AND

CONSTRUCTION ACCESS UNDERNEATH THESE BRIDGES ARE NOT ALLOWED.

CULVERT NOTES

1. CULVERT CONSTRUCTION TO BE IN ACCORDANCE WITH HARRIS COUNTY FLOOD CONTROL SPECIFICATIONS 02611, 02612, 02505, AND 02632 WITH ALL AMENDMENTS THERETO EXCEPT AS MODIFIED UNDER THIS CONTRACT. REINFORCED CONCRETE PIPE STORM SEWER SHALL CONFORM TO ASTM C-76, CLASS III USING RUBBER GASKET JOINTS ONLY

CONFORMING TO ASTM 443.

2. CONTRACTOR SHALL MAINTAIN FLOWS IN DITCHES DURING CONSTRUCTION AND RESTORE DITCHES DAMAGED DURING

CONSTRUCTION TO ORIGINAL CONDITION OR BETTER.

STORM WATER POLLUTION PREVENTION PLAN NOTES

1. THIS PROJECT DISTURBS ±5 ACRES, THEREFORE, A CONSTRUCTION GENERAL PERMIT FOR STORM WATER

DISCHARGES IS REQUIRED. THE CONTRACTOR SHALL IMPLEMENT, INSPECT, AND MAINTAIN THE STORM WATER

POLLUTION PREVENTION PLAN.

2. THE CONTRACTOR WILL TAKE APPROPRIATE MEASURES TO PREVENT, MINIMIZE AND CONTROL THE SPILL OF HAZARDOUS MATERIAL IN THE CONSTRUCTION STAGING AREA. ALL MATERIALS BEING REMOVED AND/OR DISPOSED OF BY THE CONTRACTOR WILL BE DONE SO IN ACCORDANCE WITH STATE AND FEDERAL LAWS AND WITH THE APPROVAL

OF THE PROJECT ENGINEER.

3. AS REQUIRED ON THE STORM WATER POLLUTION PREVENTION PLAN OR AS DIRECTED BY THE ENGINEER, THE TEMPORARY EROSION AND SEDIMENTATION CONTROL FEATURES SHALL BE IN PLACE PRIOR TO CONSTRUCTION.

4. THE CONTRACTOR SHALL SCHEDULE THE WORK IN SUCH A MANNER SO THAT SEEDING AND/OR SODDING MAY BE

PERFORMED AS SOON AS POSSIBLE.

5. THE CONTRACTOR'S ATTENTION IS DIRECTED TO THE FACT THAT TEMPORARY AND PERMANENT EROSION CONTROL MEASURES MAY BE NECESSARY TO COMPLY WITH PROVISIONS OF THE TEXAS POLLUTION DISCHARGE ELIMINATION

SYSTEM (TPDES) GENERAL PERMIT AS REQUIRED UNDER THE CLEAN WATER ACT.

6. PRIOR TO GRADING OPERATIONS AND DURING PROJECT DURATION, TEMPORARY OR PERMANENT EROSION CONTROL

MEASURES SHALL BE IN PLACE TO PREVENT SEDIMENT FROM LEAVING THE PROJECT AREA.

HCFCD GENERAL NOTES

1. FENCES AND/OR OTHER ENCROACHMENTS IN THE HCFCD RIGHT-OF-WAY ARE NOT TO BE REMOVED UNLESS OTHERWISE STATED ON THE PLANS. IN CASES WHERE FENCE REMOVAL IS INDICATED ON THE PLANS, THE FENCE SHALL BE REMOVED AND PLACED NEATLY ON THE ADJACENT PROPERTY AT THE START OF CONSTRUCTION. WHERE THERE IS NOT A SEPARATE ITEM LISTED ON THE UNIT PRICE SCHEDULE, THE ENCROACHMENT REMOVAL IS

INCIDENTAL TO SITE PREPARATION AND RESTORATION.

2. DO NOT ENTER PRIVATE PROPERTY WITHOUT PROPER WRITTEN AUTHORIZATION FROM THE OWNER. PROVIDE COPY

OF WRITTEN PERMISSION TO HCFCD.

3. STRIP VEGETATION AND TOPSOIL AND STOCKPILE FOR REUSE ONSITE. MATERIAL FOUND UNACCEPTABLE BY THE ENGINEER WILL BE REMOVED AND PAID AS EXCAVATION AND OFFSITE DISPOSAL. NO SEPARATE MEASUREMENT AND PAYMENT WILL BE MADE FOR STRIPPING, STOCKPILING AND PLACING ON-SITE TOPSOIL. THE COST FOR THIS WORK WILL BE INCIDENTAL TO RELATED PAY ITEMS UNDER SPECIFICATION SECTION NUMBER 02315 LISTED ON THE UNIT

PRICE SCHEDULE.

4. RIPRAP AND GRANULAR FILL MATERIAL REMOVED DURING EXCAVATION, MEETING SPECIFICATION SECTION NUMBER 02378, SHALL BE REUSED AS DIRECTED BY THE ENGINEER. REUSED MATERIAL WILL BE MEASURED AND PAID FOR AS EXCAVATION AND ON-SITE FILL UNDER SPECIFICATION NUMBER 02315. NO SEPARATE MEASUREMENT OR PAYMENT WILL BE MADE FOR PROCESSING, HANDLING, STOCKPILING, AND PLACING MATERIAL FOUND TO BE ACCEPTABLE FOR REUSE. UPON APPROVAL OF THE ENGINEER, DISPOSAL OF NONCONFORMING RIPRAP AND GRANULAR FILL MATERIAL WILL BE MEASURED AND PAID FOR AS REMOVE AND DISPOSE OF CONCRETE RUBBLE UNDER SPECIFICATION SECTION

NUMBER 02120, MATERIAL DISPOSAL.

5. THE LOCATION AND GRADE OF THE BACKSLOPE INTERCEPTOR STRUCTURES AND SWALES MAY BE ADJUSTED IN THE FIELD BY THE ENGINEER AT THE TIME OF CONSTRUCTION. UNLESS OTHERWISE INSTRUCTED BY THE ENGINEER, THE BACKSLOPE INTERCEPTOR STRUCTURE SHALL BE SET AT A MAXIMUM DEPTH OF 2.5 FEET AND THE MINIMUM GRADE

FOR BACKSLOPE SWALES SHALL BE 0.2%.

6. ADJUST YARD DRAINS AS DIRECTED IN THE FIELD AT THE TIME OF CONSTRUCTION. PAYMENT WILL BE INCIDENTAL TO

SITE PREPARATION AND RESTORATION.

7. COMPLETED SECTIONS OF THE CHANNEL WILL BE REVEGETATED BY THE CONTRACTOR IN MAXIMUM 1500 LINEAR FOOT SEGMENTS. CONTRACTOR MAY NOT DISTURB GREATER THAN 1500 LF OF CHANNEL AT A TIME.

8. CLEAR AND REMOVE ALL SILT FROM CULVERTS, PIPES AND UNDER BRIDGES TO THE PROPOSED DESIGN GRADES TO

PROVIDE POSITIVE FLOW.

9. LENGTHS AND DIAMETERS REPRESENTED ON PLANS ARE APPROXIMATE. CONTRACTOR WILL BE RESPONSIBLE FOR

FIELD VERIFICATION PRIOR TO ORDERING MATERIALS.

10. ACTIVITIES THAT DISTURB BIRD HABITAT, INCLUDING BUT NOT LIMITED TO CLEARING, GRUBBING, AND IMPACTS TO STRUCTURES WHERE MIGRATORY BIRDS AND BALD EAGLES MIGHT NEST, REQUIRE A NEST HABITAT SURVEY. DO NOT PROCEED UNTIL HARRIS COUNTY FLOOD CONTROL DISTRICT HAS CONDUCTED A NEST HABITAT SURVEY TO VERIFY ACTIVE MIGRATORY BIRD NESTS AND BALD EAGLE NESTS ARE NOT PRESENT. THE HARRIS COUNTY FLOOD CONTROL

DISTRICT MUST PROVIDE WRITTEN AUTHORIZATION TO PROCEED.

11. WHEN BANK EROSION REPAIRS CALL FOR THE PLACEMENT OF 3"x5" GRANULAR FILL IN THE CHANNEL BOTTOM TO ESTABLISH A BASE FOR REBUILDING THE SLOPE. THE 3"x5" GRANULAR FILL SHALL BE LIMITED TO AN ELEVATION

6-INCHES ABOVE THE NORMAL WATER SURFACE ELEVATION LEVEL.

12. THE CONTRACT CONTAINS UNIT ITEMS FOR THE ESTABLISHMENT OF BEST MANAGEMENT PRACTICES FOR STORM WATER QUALITY PURPOSES. WHEN NOT CALLED FOR IN THE PROJECT PLANS, COORDINATE THE NEED AND LOCATION OF THESE UNIT ITEMS WITH THE DISTRICT REPRESENTATIVE ON SITE PRIOR TO PLACEMENT. THESE UNIT ITEMS INCLUDE, BUT ARE NOT LIMITED TO, REINFORCED SILT FENCE FOR MATERIAL STOCKPILES, ANCHORED SODDING FOR DISTURBED EARTHEN AREAS OR AROUND CONCRETE AND CONCRETE INTERCEPTOR, AND STABILIZED

CONSTRUCTION ACCESS FOR PROJECT SITE INGRESS/EGRESS.

13. WHEN INCLUDED IN THE SCOPE OF WORK, THE PURPOSE OF DEEP PLOWING THE SLOPE OR BERM OF A CHANNEL IS TO BREAK UP THE DESICCATED SOILS AND TO ELIMINATE ANY VOIDS, OR RILLING CLOSE TO THE SURFACE OF THE SLOPE OR BERM. THE CONTRACTOR WILL DEEP PLOW THE SLOPE OR BERM TO A MINIMUM DEPTH OF 2 FEET IN AREAS CONTAINING VOIDS AND/OR RILLING. IN AREAS OF VOIDS ONLY, THE SURFACE FROM WHICH THE 2 FEET DEPTH IS MEASURED WILL BE THE LEVEL OF THE SURROUNDING UNDISTURBED SOIL. IN AREAS OF RILLING, THE RILLS WILL FIRST BE KNOCKED DOWN AND LEVELED OFF. THE 2 FEET DEPTH WILL THEN BE MEASURED FROM THIS NEW

SURFACE. THE CONTRACTOR WILL DETERMINE THE MEANS AND METHODS FOR DEEP PLOWING.)

14. TREES AND PLANTS LOCATED WITHIN A DESIGNATED TREE PROTECTION ZONE (TPZ) SHALL BE PRESERVED. REFER TO SPECIFICATION SECTION 01566 - TREE AND PLANT PROTECTION, FOR DETAILED INFORMATION ON TREE AND PLANT PRESERVATION PRACTICES AND PROCEDURES INCLUDING, BUT NOT LIMITED TO, ROOT PRUNING, VEGETATION

TRIMMING, FENCING AND OTHER PRESERVATION OPERATIONS.

15. IF APPLICABLE, CONTRACTOR SHALL AVOID ANY WETLAND AREAS BEYOND THE LIMITS OF EXCAVATION AND CLEARING. AS THE FIRST WORK ITEM CONTRACTOR WILL BE RESPONSIBLE FOR INSTALLING FENCING OR OTHER MATERIAL TO IDENTIFY AND PROTECT THE IDENTIFIED WETLAND AREAS, UNLESS WETLANDS HAVE BEEN IDENTIFIED AND FENCED BY HCFCD PRIOR TO CONSTRUCTION AND CONTRACTOR HAS WRITTEN EVIDENCE OF SUCH.

16. THE GEOTECHNICAL REPORT CONTAINING GEOTECHNICAL RECOMMENDATION ON THE PROJECT IS TITLED 'ADDENDUM GEOTECHNICAL RECOMMENDATIONS (MEMORANDUM-2) CONCRETE-LINED CHANNEL ALONG STATION 11+50 TO STATION 40+00 HCFCD PROJECT NO. P118-09-00-E001', PREPARED BY CIBOR GEOCONSULTANTS, DATED

SEPT 15,2025. THE REPORT IS APPROVED BY HCFCD.

MAINTENANCE ENGINEERING CONSTRUCTION NOTES

1. THE PROJECT PLANS ARE INTENDED AS A GUIDE. THE REPAIR AREA LIMITS WILL BE DETERMINED IN THE FIELD BY THE HCFCD REPRESENTATIVE. DUE TO THE DYNAMIC CONDITIONS IN THE FIELD, PROJECT SCOPE AND QUANTITIES MAY VARY FROM THE PLANS AND/OR CROSS SECTIONS. HCFCD RESERVES THE RIGHT TO ADJUST PLANS AND QUANTITIES AS NECESSARY. PROJECT SCOPE MAY BE

ADJUSTED AS PRIORITIES CHANGE.

2. THE PURPOSE OF THE CHANNEL DESILT IS TO RESTORE POSITIVE DRAINAGE DURING LOW FLOW CONDITIONS. UNLESS SPECIFICALLY STATED OTHERWISE, IT IS NOT THE INTENT OF THE PROJECT TO DEEPEN THE CHANNEL BEYOND ITS ORIGINAL DESIGN CONFIGURATION.

EXCAVATION OF SILT SHOULD NOT UNDERMINE THE TOE OF THE SLOPE.

RETAINED ON SEIVE

3" 20 - 30 10 - 20

0 - 10

% BY WEIGHT

5"

4"

STREAMBED FILL NOTES

1. STREAMED FILL SHALL CONSIST OF A WELL GRADED MIXTURE OF

MATERIAL OF RECYCLED CONCRETE TO 3"X5" GRANULAR FILL. THE

MIXTURE SHALL CONSIST OF APPROXIMATELY 30% GRANULAR FILL

AND 70% CRUSHED CONCRETE. THE CRUSHED CONCRETE SHALL

MEET CRITERIA SHOWN IN THE TABLE BELOW, AND WHEN TESTED IN

ACCORDANCE WITH ASTM C136 % BY WEIGHT.

7/8"

2"

1 3/4"

3/8" #4

#40

#200

45 - 55

50 - 60

60 - 70

70 - 80 75 - 85

85 - 95

90 - 100

WELL GRADED MIX NOTES

1. PAYMENT FOR THE WELL GRADED MIXTURE WILL BE MADE BY

THE UNIT ITEM 2378-05, GRANULAR FILL, GRAVEL TO RIPRAP

GRADATION NO. 2, AS DIRECTED BY THE ENGINEER.

2. INSTALLATION OF WELL GRADED MIXTURE IN THE SCOURED

CHANNEL BOTTOM SHALL CONSIST OF A WELL GRADED MIXTURE

OF MATERIAL FROM GRAVEL TO GRADE #1 RIPRAP, TO MINIMIZE

VOIDS. THE MIXTURE SHALL CONSIST OF APPROXIMATELY 30%

GRADE #1 RIPRAP, 55% 3"X5" CRUSHED ROCK AND 15% RECYCLED

CRUSHED CONCRETE BASE MATERIAL(GRAVEL). THE CRUSHED

BASE MATERIAL SHALL MEET CRITERIA SHOWN IN THE TABLE

BELOW, WHEN TESTED IN ACCORDANCE WITH ASTM C 136:

RETAINED ON SQUARE SEIVE

3/8" 30 - 50 10 - 35

% BY WEIGHT

1 3/4"

7/8"

NO. 4

NO. 40

45 - 65

70 - 85

SHEET NUMBER

DATE:

PR

EP

AR

ED

C H

EC

KE

D

AP

PR

O

VE

D

OF

C H

EC

KE

D

AP

PR

O

VE

D

R

EV

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

ST

ATE OF TEXAS

PROFESS IONAL ENGIN

EE

RL I CENSED

H C

FC

D

P R

O

JE

C T

ID

P1

-0 9-

-X

C O

N C

R

ET

E C

H

AN

N

EL

R

EP

AI

R

H C

FC

D

U N

IT

P1

-0 9-

11750 Katy Freeway, Suite 1260 Houston, TX 77079

800.414.1045

P:

\2

3\

.0 1_

CO

H

CO

NC

RE

TE

L

IN

IN

G\

DR

AW

IN

GS

\S

HE

ET

S\

6_

GE

NE

RA

L

NO

TE

S (2

O F

2) .D

W G

S

AV

ED

: T hu rs da y, Fe br ua ry

, 2

9:

:1

AM |

H

CF

CD

_1 1X

_N

CS

F

IN

AL

LO

TT

ED

: Fr ida y, Fe br ua ry

, 2

9:

:0

AM

SCALE:

G

EN

ER

AL

N O

TE

S

(2 O

F 2)

SB PG N

W

FEB. 2026

AS SHOWN

4 42

NOTICE

FOR YOUR SAFETY, YOU ARE REQUIRED BY TEXAS LAW TO CALL 811 AT

LEAST 48 HOURS BEFORE YOU DIG SO THAT UNDERGROUND LINES CAN BE

MARKED. THIS SIGNATURE DOES NOT FULFILL YOUR OBLIGATION TO CALL

811.

VERIFICATION OF PRIVATE UTILITY LINES

Date

CENTERPOINT ENERGY NATURAL GAS UTILITIES SHOWN. (GAS SERVICE

LINES ARE NOT SHOWN). THIS SIGNATURE NOT TO BE USED FOR CONFLICT

VERIFICATION SIGNATURE VALID FOR SIX MONTHS.

Date

CENTERPOINT ENERGY/UNDERGROUND ELECTRICAL FACILITIES

VERIFICATION ONLY. (THIS SIGNATURE VERIFIES EXISTING UNDERGROUND

FACILITIES - NOT TO BE USED FOR CONFLICT VERIFICATION.) SIGNATURE

VALID FOR SIX MONTHS.

Date

AT&T APPROVED FOR AT&T TEXAS/SWBT FACILITIES UNDERGROUND

CONDUIT ONLY.

UTILITY NOTES:

CENTERPOINT ENERGY RESOURCES CORP. (GAS)

CAUTION UNDERGROUND GAS FACILITIES

THE CONTRACTOR SHALL CONTACT THE UTILITY COORDINATING COMMITTEE AT 1-800-545-6005 OR 811 A MINIMUM OF

48 HOURS PRIOR TO CONSTRUCTION TO HAVE MAIN AND SERVICE LINES FIELD LOCATED.

· WHEN CENTERPOINT ENERGY PIPE LINE MARKINGS ARE NOT VISIBLE, CALL (713) 207-5463 OR (713) 945-8037 (7:00

A.M. TO 4:30 P.M.) FOR STATUS OF LINE LOCATION REQUEST BEFORE EXCAVATION BEGINS.

· WHEN EXCAVATING WITHIN EIGHTEEN INCHES (18”) OF THE INDICATED LOCATION OF CENTERPOINT ENERGY FACILITIES, ALL EXCAVATION MUST BE ACCOMPLISHED USING NON-MECHANIZED EXCAVATION PROCEDURES.

· WHEN CENTERPOINT ENERGY FACILITIES ARE EXPOSED, SUFFICIENT SUPPORT MUST BE PROVIDED TO THE

FACILITIES TO PREVENT EXCESSIVE STRESS ON THE PIPING.

· FOR EMERGENCIES REGARDING GAS LINES CALL (713) 659-2111 OR (713) 207-4200.

THE CONTRACTOR IS FULLY RESPONSIBLE FOR ANY DAMAGES CAUSED BY HIS FAILURE TO EXACTLY LOCATE AND

PRESERVE THESE UNDERGROUND FACILITIES.

CENTERPOINT ENERGY HOUSTON ELECTRIC LLC

WARNING OVERHEAD ELECTRICAL FACILITIES

OVERHEAD LINES MAY EXIST ON THE PROPERTY. THE LOCATION OF OVERHEAD LINES HAS NOT BEEN SHOWN ON THESE DRAWINGS AS THE LINES ARE CLEARLY VISIBLE, BUT YOU SHOULD LOCATE THEM PRIOR TO BEGINNING ANY CONSTRUCTION. TEXAS LAW, SECTION 752, HEALTH & SAFETY CODE FORBIDS ACTIVITIES THAT OCCUR IN CLOSE

PROXIMITY TO HIGH VOLTAGE LINES, SPECIFICALLY:

· ANY ACTIVITY WHERE PERSON OR THINGS MAY COME WITHIN SIX(6) FEET OF LIVE OVERHEAD HIGH VOLTAGE

LINES; AND

· OPERATING A CRANE, DERRICK, POWER SHOVEL, DRILLING RIG, PILE DRIVER, HOISTING EQUIPMENT, OR SIMILAR

APPARATUS WITHIN 10 FEET OF LIVE OVERHEAD HIGH VOLTAGE LINES.

PARTIES RESPONSIBLE FOR THE WORK, INCLUDING CONTRACTORS ARE LEGALLY RESPONSIBLE FOR THE SAFETY OF CONSTRUCTION WORKERS UNDER THIS LAW. THIS LAW CARRIES BOTH CRIMINAL AND CIVIL LIABILITY. TO ARRANGE

FOR LINES TO BE TURNED OFF OR REMOVED CALL CENTERPOINT ENERGY AT (713) 207-2222.

ACTIVITIES ON/OR ACROSS CENTERPOINT ENERGY FEE OR EASEMENT PROPERTY

NO APPROVAL TO USE, CROSS OR OCCUPY CENTERPOINT FEE OR EASEMENT PROPERTY IS GIVEN. IF YOU NEED TO USE CENTERPOINT PROPERTY, PLEASE CONTACT OUR SURVEYING & RIGHT OF WAY DIVISION AT (713) 207-6348 OR

(713) 207-5769.

AT&T TEXAS/SWBT FACILITIES:

1. THE LOCATIONS OF AT&T TEXAS/SWBT FACILITIES ARE SHOWN IN AN APPROXIMATE WAY ONLY. THE CONTRACTOR SHALL DETERMINE THE

EXACT LOCATION BEFORE COMMENCING WORK. HE AGREES TO BE FULLY RESPONSIBLE FOR ALL DAMAGES WHICH MIGHT BE OCCASIONED BY THIS FAILURE TO EXACTLY LOCATE AND PRESERVE THESE UNDERGROUND UTILITIES.

2. THE CONTRACTOR SHALL CALL 1-800-344-8377 (TEXAS 811) A MINIMUM OF 48 HOURS PRIOR TO CONSTRUCTION TO HAVE UNDERGROUND

LINES FIELD LOCATED.

3. WHEN EXCAVATING WITHIN EIGHTEEN INCHES (18”) OF THE INDICATED LOCATION OF AT&T TEXAS/SWBT FACILITIES, ALL EXCAVATIONS MUST BE ACCOMPLISHED USING NON-MECHANIZED EXCAVATION PROCEDURES. WHEN BORING, THE CONTRACTOR SHALL EXPOSE THE

AT&T TEXAS/SWBT FACILITIES.

4. WHEN AT&T TEXAS/SWBT FACILITIES ARE EXPOSED, THE CONTRACTOR WILL PROVIDE SUPPORT TO PREVENT DAMAGE TO THE CONDUIT DUCTS OR CABLES. WHEN EXCAVATING NEAR TELEPHONE POLES THE CONTRACTOR SHALL BRACE THE POLE FOR SUPPORT.

5. THE PRESENCE OR ABSENCE OF AT&T TEXAS/SWBT UNDERGROUND CONDUIT FACILITIES OR BURIED CABLE FACILITIES SHOWN ON THESE PLANS DOES NOT MEAN THAT THERE ARE NO DIRECT BURIED CABLES OR OTHER CABLES IN CONDUIT IN THE AREA.

6. PLEASE CONTACT THE AT&T TEXAS DAMAGE PREVENTION MANAGER KEVIN RAY (713) 614-1983 OR E-MAIL HIM @ kr7896@att.com IF CABLE

LOCATE REQUESTS ARE NOT COMPLETED FOR OUR AT&T TEXAS/SWBT FACILITIES.

DIRECT BURIED CABLE LOCATES:

1. TO DETERMINE THE LOCATION OF AT&T DIRECT BURIED CABLE PLANT DURING THE DESIGN PHASE OF YOUR PROJECT, FOLLOW THE

PROCEDURE OUTLINED BELOW:

2. CALL 1-800-344-8377 (TEXAS 811) AND ADVISE YOU NEED THE EXISTING AT&T TEXAS/SWBT FACILITIES LOCATED FOR THE DESIGN PHASE OF YOUR PROJECT. PLEASE ALLOW AT LEAST 72 HOURS FOR THE CABLES TO GET MARKED BEFORE SENDING YOUR FIELD CREW FOR BASE LINE SURVEY FOR LOCATES OF. BE SPECIFIC ON THE PROJECT LOCATION. THE UTILITY LOCATOR WILL FIELD LOCATE THE EXISTING AT&T

TEXAS/SWBT FACILITIES WITH ORANGE PAINT AND/OR FLAGS.

3. YOUR FIELD PARTY CAN SURVEY THE BURIED CABLE LOCATION USING THE ORANGE MARKS ON THE GROUND. IF THE CABLES ARE NOT MARKED, PLEASE CONTACT THE AT&T TEXAS DAMAGE PREVENTION MANAGER KEVIN RAY (713) 614-1983 OR E-MAIL @ kr7896@att.com.

4. DEPICT THE EXACT LOCATION OF THE AT&T TEXAS/SWBT DIRECT BURIED CABLE FACILITIES ON THE PLAN AND PROFILE SHEETS.

PROJECT SPECIFIC NOTES / MAGELLAN PIPELINE COMPANY, L.P.

1. THE MAGELLAN REPRESENTATIVE MUST BE NOTIFIED 48-HOURS PRIOR TO ANY WORK BEGINNING. MUST

PLACE ONE CALL AND NOTIFY ANTONIO DOMINO, SR., 281-607-6521.

2. NO WORK IS TO COMMENCE WITHIN 25 FEET OF EASEMENT WITHOUT THE MAGELLAN REPRESENTATIVE

BEING PRESENT, AND REPRESENTATIVE MUST BE ONSITE FOR THE INSTALLATION.

3. THE MAGELLAN REPRESENTATIVE MUST ALSO BE PRESENT FOR ANY ONGOING ACTIVITIES WITHIN THE

ROW, AND ANY BACKFILLING PROCESSES OF THE SITE.

2/12/26

02/17/26

02/17/26

2/19/2026

SHEET NUMBER

DATE:

PR

EP

AR

ED

C H

EC

KE

D

AP

PR

O

VE

D

OF

C H

EC

KE

D

AP

PR

O

VE

D

R

EV

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

ST

ATE OF TEXAS

PROFESS IONAL ENGIN

EE

RL I CENSED

H C

FC

D

P R

O

JE

C T

ID

P1

-0 9-

-X

C O

N C

R

ET

E C

H

AN

N

EL

R

EP

AI

R

H C

FC

D

U N

IT

P1

-0 9-

11750 Katy Freeway, Suite 1260 Houston, TX 77079

800.414.1045

P:

\2

3\

.0 1_

CO

H

CO

NC

RE

TE

L

IN

IN

G\

DR

AW

IN

GS

\S

HE

ET

S\

7_

PR

OJ

L

GN

D

AN

D

AB

BV

.D

W G

S

AV

ED

: M on da y, Ja nu ar y 1

2, :3

9:

A M

H

CF

CD

_1 1X

_N

CS

F

IN

AL

LO

TT

ED

: Th ur sd ay , F eb ru ar y 1

9, :2

9:

A M

SCALE:

PR

O

JE

C

T

LE

G

EN

D A

N D

A

BB

R

EV

IA

TI

O N

S

SB PG N

W

FEB. 2026

NONE

5 42

ABBREVIATIONS

AC ACRE

APPROX APPROXIMATE

BC BACK OF CURB

B/S BACKSLOPE SWALE

BOP BEGINNING OF PROJECT

BMP BEST MANAGEMENT PRACTICES

C/L CENTERLINE

CJ CONSTRUCTION JOINT

CNP CENTERPOINT

COH CITY OF HOUSTON

CONC CONCRETE

CONST CONSTRUCTION

DET DETAIL

DWG DRAWING

E EASTING

EA EACH

EW EACH WAY

ELEV ELEVATION

EP EDGE OF PAVEMENT

EOP END OF PROJECT

ESMT EASEMENT

EXIST EXISTING

EJ EXPANSION JOINT

FG FINISHED GRADE

FL FLOWLINE

FM FORCEMAIN

FNC FENCE

HCFCD HARRIS COUNTY FLOOD CONTROL

DISTRICT

HP HIGH POINT

JB JUNCTION BOX

LF LINEAR FEET

MAINT MAINTENANCE

MAX MAXIMUM

MIN MINIMUM

MISC MISCELLANEOUS

N NORTHING

NTS NOT TO SCALE

OC ON CENTER

OH OVERHEAD UTILITY LINE

OHWM ORDINARY HIGH WATER MARK

PC POINT OF CURVATURE

PI POINT OF INTERSECTION

PRC POINT OF REVERSE CURVATURE

PT POINT OF TANGENCY

P/L PROPERTY LINE

PERM. PERMANENT

PROP PROPOSED

PT POINT

PVMT PAVEMENT

R RADIUS

REINF REINFORCING

ROW RIGHT OF WAY

SAN SANITARY

SF SQUARE FOOT

STL STEEL

TBM TEMPORARY BENCH MARK

TEMP TEMPORARY

TOB TOP OF BANK

TOE TOE OF SLOPE

TYP TYPICAL

UNO UNLESS NOTED OTHERWISE

W/ WITH

LEGEND

EXISTING BOREHOLE LOCATION

EXISTING STRUCTURE

PROJECT BASELINE

EXISTING RIGHT-OF-WAY

EXISTING LOT LINE

EXISTING EASEMENT

EXISTING CULVERT

EXISTING SEWER MANHOLE

EXISTING STORM MANHOLE

EXISTING STORM INLET

EXISTING STORM SEWER LINE

EXISTING SANITARY SEWER

EXISTING FORCEMAIN

EXISTING FIRE HYDRANT

EXISTING WATER VALVE

EXISTING WATER METER

EXISTING WATER LINE

EXISTING GUY WIRE

EXISTING POWER POLE

EXISTING POWER POLE W/RISER

EXISTING OVERHEAD UTILITY LINE

EXISTING BURIED POWER LINE

EXISTING TELECOM

EXISTING TELECOM MANHOLE

EXISTING TELECOM HANDHOLE

EXISTING TELECOM PEDESTAL

EXISTING GAS LINE

EXISTING UNKNOWN UTILITY

EXISTING QL-C / QL-D

EXISTING WOODEN FENCE

EXISTING CHAINLINK FENCE

EXISTING PIPE LINE (MAGELLAN)

EXISTING PIPE LINE (CHEVRON)

EXISTING CONCRETE

PROPOSED 8" THICK CONC CHANNEL LINING

PROPOSED RIPRAP GRADATION NO 2

PROPOSED GRASS LINED AREA

EXISTING TOP OF SLOPE

EXISTING TOE OF SLOPE

PROPOSED TOP OF SLOPE

PROPOSED TOE OF SLOPE

EXISTING CHANNEL FLOW DIRECTION

EXISTING WETLANDS

SS

GAS

BORE 7 STABILIZED CONSTRUCTION ACCESS

REINFORCED SILT FENCE

WATER LEVEL ELEVATION

INLET PROTECTION BARRIER

CONCRETE TRUCK WASHOUT

TYPE 2 REINFORCED ROCK FILTER DAM

HYDRO MULCH

DETAIL NUMBER

SHEET NUMBER

VIEW DIRECTION

SECTION LETTER

SHEET NUMBER

IP

A

SAN

CTW

FLOW

PIPE-1

FM

PIPE-2

6 42

OH OH OH OH OH OHOH OH OH OH OH OH GAS GAS

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2

SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SANGAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS

SS

PP1 (SHEET NO. 14) PP2 (SHEET NO. 15) PP3 (SHEET NO. 16)

BI

G

W O

O D

S

TR

EE

T

12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 21+00 22+00 23+00 24+00 25+00

BEGIN PROJECT

STA. 12+00.00

X

OH OH

OH

O H

OH OH OH OH OHOH OH

SS

SS

SS

SS

U G

E-1

OH OH OH OH

OH OH

GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2

SAN SAN SAN SAN SAN SAN SAN SAN SAN SANGAS GAS GAS GAS

SS

G

AS

PP4 (SHEET NO. 17) PP5 (SHEET NO. 18) PP6 (SHEET NO. 19)

PAR

KER

R O

AD

26+00 27+00 28+00 29+00 30+00 31+00 32+00 33+00 34+00 35+00 36+00 37+00 38+00 39+00 40+00

G

LE

AS

O

N R

O

AD

END PROJECT

STA. 39+62.00

Houston, Texas 77092 9900 Northwest Freeway

SHEET NUMBER

DATE:

PR

EP

AR

ED

C H

EC

KE

D

AP

PR

O

VE

D

OF

C H

EC

KE

D

AP

PR

O

VE

D

R

EV

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

ST

ATE OF TEXAS

PROFESS IONAL ENGIN

EE

RL I CENSED

H C

FC

D

P R

O

JE

C T

ID

P1

-0 9-

-X

C O

N C

R

ET

E C

H

AN

N

EL

R

EP

AI

R

H C

FC

D

U N

IT

P1

-0 9-

11750 Katy Freeway, Suite 1260 Houston, TX 77079

800.414.1045

P:

\2

3\

.0 1_

CO

H

CO

NC

RE

TE

L

IN

IN

G\

DR

AW

IN

GS

\S

HE

ET

S\

1_

PR

OJ

EC

T

LA

YO

UT

.D

W G

S

AV

ED

: M on da y, Ja nu ar y 1

9, 5:

:4

PM |

H

CF

CD

_1 1X

_N

CS

F

IN

AL

LO

TT

ED

: Th ur sd ay , F eb ru ar y 1

9, :3

0:

A M

SCALE:

PR

O

JE

C

T

LA

YO

U

T

PL

AN

SB PG N

W

FEB. 2026

AS SHOWN

7 42

B

EG

IN

P

R O

JE

C

T

ST

A . 1

1+

M A

TC

H

L

IN

E S

TA

. 2

5+

(T H

IS

S

H

EE

T)

0' 50' 100'

EN

D

P R

O

JE

C T

ST

A

. 4 0+

M A

TC

H

L

IN

E S

TA

. 2

5+

(T H

IS

S

H

EE

T)

40' HCFCD DRAINAGE EASEMENT

60' TEXAS PIPELINE COMPANY R.O.W.

10' UTILITY EASEMENT

10' UTILITY EASEMENT

60' TEXAS PIPELINE COMPANY R.O.W.

10' UTILITY EASEMENT

40' HCFCD DRAINAGE EASEMENT

10' UTILITY EASEMENT

PROP LEFT HIGH BANK

PROP RIGHT HIGH BANK

PROP RIGHT HIGH BANK

PROP LEFT HIGH BANK

HCFCD ROW

HCFCD ROW

HCFCD ROW

HCFCD ROW

LEGEND

PROPOSED 8" THICK CONC

CHANNEL LINING

PROPOSED RIPRAP

GRADATION NO 2

PROPOSED GRASS LINED

AREA

PROPOSED TOP OF SLOPE

PROPOSED TOE OF SLOPE

O H

OH OH OH OH OH OH OH OH

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1

PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2

SAN SAN SAN SAN SAN SAN SAN SAN SANGAS GAS GAS GAS GAS GAS GAS GAS GAS

SS

BI

G

W O

O D

S

TR

EE

T

HCFCD ROW

HCFCD ROW

HCFCD ROW

CHEVRON PIPELINE

MAGELLAN PIPELINE CO. LP

EXIST TOE OF SLOPE

EXIST HIGH BANK

EXIST HIGH BANK

EXIST TOE OF SLOPE

EXIST HIGH BANK

EXIST TOE OF SLOPE

EXIST HIGH BANK

CAUTION!!!

UNDERGROUND

GAS LINE

REMOVE RIPRAP

REMOVE CONCRETE

CHANNEL LINING

REMOVE CONCRETE

CHANNEL LINING

REMOVE CONCRETE

CHANNEL LINING

REMOVE RIPRAP

REMOVE CONCRETE

CHANNEL LINING

REMOVE RIPRAP

REMOVE RIPRAP

REMOVE CONCRETE

CHANNEL LINING

REMOVE CONCRETE

BOTTOM

12+00 13+00 14+00 15+00 16+00 17+00 18+00

EXIST TREE LINECNP OVERHEAD ELEC

EXIST 30" RCP

EXIST CHAINLINK FENCE

CNP 2" IP STL GAS LINE

EXIST

FIBEROPTIC BOX

8" COH WATERLINE

(PER SUE & GIMS)

EXIST PIPE FENCE

EXIST

GUARDRAIL

EXIST OVERHEAD ELEC

CNP 2" IP STL GAS LINE

EXIST CHAINLINK FENCE

EXIST CHAINLINK FENCE

EXIST

60" RCP

HCFCD ROW

EXIST TOE OF SLOPE

10' UTILITY ESMT

VOL 46, PG 9 HCMR

60' TEXAS PIPELINE

COMPANY ROW

VOL 2471, PGS 547 & 550,

HCDR

10' UTILITY ESMT

VOL 46, PG 9 HCMR

PROPERTY LINE

FLOW

STA: 12+16

STA: 12+73

STA: 13+51 STA: 14+78

STA: 17+82

STA: 12+17 STA: 15+50 STA: 16+10 STA: 17+77STA: 17+09

HCFCD UNIT NO P118-09-00

40' DRAINAGE ESMT

VOL 46, PG 9, HCMR

SCENIC WOODS

VOL. 46, PG 9, HCMR

SCENIC WOODS

VOL. 46, PG 9, HCMR

P118-09-00

REMOVE & DISPOSE

WATERLINE

(INCIDENTAL TO

CHANNEL WORK)

OH OH OH OH OH OHOH GAS GAS

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1

PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2

SAN SAN SAN SAN SAN SAN SAN SANGAS GAS GAS GAS GAS GAS GAS

HCFCD ROW

HCFCD ROW

MAGELLAN PIPELINE CO LP

CHEVRON PIPELINE

EXIST HIGH BANK

EXIST TOE OF SLOPE

EXIST HIGH BANK

EXIST TOE OF SLOPE

CAUTION!!!

OVERHEAD

ELECTRIC LINE

CAUTION!!!

UNDERGROUND

GAS LINE

CAUTION!!!

OVERHEAD

ELECTRIC LINE P118-09-00

REMOVE CONCRETE

CHANNEL LINING

REMOVE RIPRAP

REMOVE RIPRAP

REMOVE CONCRETE

CHANNEL LINING

REMOVE CONCRETE

CHANNEL LINING

REMOVE RIPRAP

REMOVE RIPRAP

REMOVE CONCRETE

CHANNEL LINING

REMOVE RIPRAP

REMOVE CONCRETE

CHANNEL LINING

REMOVE CONCRETE

CHANNEL LINING

REMOVE RIPRAP

REMOVE CONCRETE

BOTTOM

19+00 20+00 21+00 22+00 23+00 24+00 25+00

CNP 2" IP STL

GAS LINE

EXIST CHAINLINK

FENCE

EXIST WOOD FENCE

EXIST SAN. SWR. MH

EXIST 18" RCP

EXIST CHAINLINK FENCE

EXIST OVERHEAD ELEC

EXIST WOOD FENCE

PROPERTY LINE

FLOW

STA: 19+30

STA: 19+94

STA: 19+92

STA: 20+46

STA: 20+36

STA: 21+43

STA: 24+60

STA: 21+38 STA: 21+75

HCFCD UNIT NO P118-09-00

40' DRAINAGE ESMT

VOL 46, PG 9, HCMR

SCENIC WOODS

VOL. 46, PG 9, HCMR

SCENIC WOODS

VOL. 46, PG 9, HCMR

10' UTILITY ESMT

VOL 46, PG 9 HCMR

60' TEXAS PIPELINE

COMPANY ROW

VOL 2471, PGS 547 & 550,

HCDR

10' UTILITY ESMT

VOL 46, PG 9 HCMR

Houston, Texas 77092 9900 Northwest Freeway

SHEET NUMBER

DATE:

PR

EP

AR

ED

C H

EC

KE

D

AP

PR

O

VE

D

OF

C H

EC

KE

D

AP

PR

O

VE

D

R

EV

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

ST

ATE OF TEXAS

PROFESS IONAL ENGIN

EE

RL I CENSED

H C

FC

D

P R

O

JE

C T

ID

P1

-0 9-

-X

C O

N C

R

ET

E C

H

AN

N

EL

R

EP

AI

R

H C

FC

D

U N

IT

P1

-0 9-

11750 Katy Freeway, Suite 1260 Houston, TX 77079

800.414.1045

P:

\2

3\

.0 1_

CO

H

CO

NC

RE

TE

L

IN

IN

G\

DR

AW

IN

GS

\S

HE

ET

S\

2_

CL

EA

RI

NG

G

RU

BB

IN

G.

DW

G

S

AV

ED

: M on da y, Ja nu ar y 1

9, 4:

:1

PM |

H

CF

CD

_1 1X

_N

CS

F

IN

AL

LO

TT

ED

: Th ur sd ay , F eb ru ar y 1

9, :3

0:

A M

SCALE:

C

LE

AR

IN

G , G

R U

BB

IN

G

D

EM

O P

LA

N

(1 O

F 2)

SB PG N

W

FEB. 2026

AS SHOWN

8 42

0' 30' 60'

B

EG

IN

P

R O

JE

C

T

ST

A . 1

1+

M A

TC

H

L

IN

E S

TA

. 1

8+

(S

EE

T H

IS

S

H

EE

T) M

A

TC

H L

IN

E

S

TA

. 2 5+

(S

EE

S

H

EE

T N

O . 9

M A

TC

H

L

IN

E S

TA

. 1

8+

(S

EE

T H

IS

S

H

EE

T)

NOTES

1. ALL MATERIAL TO BE REMOVED

SHALL BE DISCARDED OFF-SITE.

FLOW

LIMITS OF CLEARING AND

GRUBBING

REMOVE AND DISPOSE OF

EXISTING CONCRETE CHANNEL

LINING

EXISTING CONCRETE

EXISTING RIPRAP

REMOVE AND DISPOSE OF

EXISTING RIPRAP

REMOVE AND DISPOSE OF

CONCRETE BOTTOM

CHANNEL FLOW

EXISTING CULVERT

REMOVE AND DISPOSE OF

EXISTING CONCRETE OR

METAL PIPE (ALL SIZE)

PRESERVE AND PROTECT

EXISTING TREES

LEGEND

X

OHOH OH

OH

O H

OH OH OH OHOH OH

SS

SS

SS

SS

GAS GAS GAS GAS

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1

PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2

SAN SAN SAN SAN SAN SAN

GAS GAS GAS GAS

HCFCD ROW

HCFCD ROW

CHEVRON PIPELINE

MAGELLAN PIPELINE CO. LP

CHEVRON PIPELINE

MAGELLAN PIPELINE CO. LP

EXIST HIGH BANK

EXIST TOE OF SLOPE

EXIST HIGH BANK

EXIST TOE OF SLOPE

CAUTION!!!

UNDERGROUND

GAS LINE

P118-09-00

REMOVE RIPRAP

REMOVE CONCRETE

CHANNEL LINING

REMOVE RIPRAP

REMOVE RIPRAP REMOVE CONCRETE

CHANNEL LINING

REMOVE RIPRAP

REMOVE RIPRAP REMOVE RIPRAP

REMOVE CONCRETE

CHANNEL LINING

REMOVE CONCRETE

CHANNEL LINING

REMOVE CONCRETE

BOTTOM

26+00 27+00 28+00 29+00 30+00 31+00 32+00

PAR

KER

R O

AD

EXIST CHAINLINK FENCE CNP 2" IP STL

GAS LINE

EXIST

CHAINLINK

FENCE

EXIST WOOD

FENCE

CNP OVERHEAD ELEC

EXIST CHAINLINK FENCE

EXIST SAN. SWR. MH10' UTILITY ESMT

VOL 46, PG 9 HCMR

60' TEXAS PIPELINE

COMPANY ROW

VOL 2471, PGS 547 &

550, HCDR

10' UTILITY ESMT

VOL 46, PG 9 HCMR

FLOW

EXIST 54" RCP

STA: 26+15

STA: 26+14

STA: 27+21

STA: 27+21

STA: 28+25

STA: 28+25

STA: 29+32

STA: 29+49

STA: 31+02

STA: 30+53

STA: 31+81

COH WATER

(PER SUE)

COH WATER

(PER SUE)

CNP

OVERHEAD

ELEC

EXIST SAN. SWR.

HCFCD UNIT NO

P118-09-00

40' DRAINAGE ESMT

VOL 46, PG 9, HCMR

SCENIC WOODS

VOL. 46, PG 9, HCMR

SCENIC WOODS

VOL. 46, PG 9, HCMR

10' UTILITY ESMT

VOL 46, PG 9 HCMR

60' TEXAS PIPELINE

COMPANY ROW

VOL 2471, PGS 547 &

550, HCDR

10' UTILITY ESMT

VOL 46, PG 9 HCMR

STA: 25+65

REMOVE & DISPOSE

WATERLINE

(INCIDENTAL TO

CHANNEL WORK)

OH OH OH OH OHOH

OH

O H

OH

G

AS

GAS GAS GAS GAS GAS GAS GAS

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1

PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2

SAN SAN SAN SAN SAN SAN SANGAS

SS

G

LE

AS

O

N R

O

AD

CHEVRON PIPELINE

MAGELLAN PIPELINE CO. LP

HCFCD ROW HCFCD ROW

HCFCD ROW

EXIST HIGH BANK

EXIST TOE OF SLOPE

EXIST HIGH BANK

EXIST TOE OF SLOPE

EXIST HIGH BANK

EXIST TOE OF SLOPE

EXIST HIGH BANK

EXIST TOE OF

SLOPE

EXIST TOE OF SLOPE

EXIST HIGH BANK

CAUTION!!!

OVERHEAD

ELECTRIC LINE

CAUTION!!!

OVERHEAD

ELECTRIC LINE

CAUTION!!!

UNDERGROUND

GAS LINE

HCFCD ROW

HCFCD ROW

P118-09-00

REMOVE CONCRETE

CHANNEL LINING

REMOVE RIPRAP

REMOVE CONCRETE

CHANNEL LINING

REMOVE CONCRETE

CHANNEL LINING

REMOVE CONCRETE

BOTTOM

33+00 34+00 35+00 36+00 37+00 38+00 39+00

EXIST CHAINLINK

FENCE

CNP 2" IP STL GAS LINE

EXIST WOOD FENCE

EXIST CHAINLINK FENCE

CNP OVERHEAD ELEC

EXIST CHAINLINK FENCE

EXIST 30" RCP

COH WATER

(PER SUE)

EXIST GUARDRAIL

MCI FIBEROPTIC LINE

EXIST WOOD FENCE

CNP 2" IP STL GAL LINE

EXIST GUARDRAIL

COH WATER

(PER SUE)

EXIST WOOD FENCE

EXIST 54" RCP

EXIST 18" RCP

EXIST 18" RCP

10' UTILITY ESMT

VOL 46, PG 9 HCMR

60' TEXAS PIPELINE

COMPANY ROW

VOL 2471, PGS 547 &

550, HCDR

10' UTILITY ESMT

VOL 46, PG 9 HCMR

REMOVE CONCRETE

CHANNEL LINING

FLOW

STA: 32+67

STA: 32+96

STA: 33+29

STA: 37+75STA: 37+39

STA: 38+16

STA: 38+38

HCFCD UNIT NO P118-09-00

40' DRAINAGE ESMT

VOL 46, PG 9, HCMR

SCENIC WOODS

VOL. 46, PG 9, HCMR

SCENIC WOODS

VOL. 46, PG 9, HCMR

REMOVE & DISPOSE

WATERLINE

(INCIDENTAL TO

CHANNEL WORK)

Houston, Texas 77092 9900 Northwest Freeway

SHEET NUMBER

DATE:

PR

EP

AR

ED

C H

EC

KE

D

AP

PR

O

VE

D

OF

C H

EC

KE

D

AP

PR

O

VE

D

R

EV

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

ST

ATE OF TEXAS

PROFESS IONAL ENGIN

EE

RL I CENSED

H C

FC

D

P R

O

JE

C T

ID

P1

-0 9-

-X

C O

N C

R

ET

E C

H

AN

N

EL

R

EP

AI

R

H C

FC

D

U N

IT

P1

-0 9-

11750 Katy Freeway, Suite 1260 Houston, TX 77079

800.414.1045

P:

\2

3\

.0 1_

CO

H

CO

NC

RE

TE

L

IN

IN

G\

DR

AW

IN

GS

\S

HE

ET

S\

2_

CL

EA

RI

NG

G

RU

BB

IN

G.

DW

G

S

AV

ED

: M on da y, Ja nu ar y 1

9, 4:

:1

PM |

H

CF

CD

_1 1X

_N

CS

F

IN

AL

LO

TT

ED

: Th ur sd ay , F eb ru ar y 1

9, :3

0:

A M

SCALE:

C

LE

AR

IN

G , G

R U

BB

IN

G

D

EM

O P

LA

N

(2 O

F 2)

SB PG N

W

FEB. 2026

AS SHOWN

9 42

0' 30' 60'

(S

EE

T H

IS

S

H

EE

T) M

A

TC

H L

IN

E

S

TA

. 3 2+

M A

TC

H

L

IN

E S

TA

. 3

2+

(S

EE

T H

IS

S

H

EE

T)

EN

D P

R O

JE

C

T

ST

A . 3

9+

.1

(S

EE

S H

EE

T

N O

. 8

M A

TC

H

L

IN

E S

TA

. 2

5+

NOTES

1. ALL MATERIAL TO BE REMOVED

SHALL BE DISCARDED OFF-SITE.

FLOW

LIMITS OF CLEARING AND

GRUBBING

REMOVE AND DISPOSE OF

EXISTING CONCRETE CHANNEL

LINING

EXISTING CONCRETE

EXISTING RIPRAP

REMOVE AND DISPOSE OF

EXISTING RIPRAP

REMOVE AND DISPOSE OF

CONCRETE BOTTOM

CHANNEL FLOW

EXISTING CULVERT

REMOVE AND DISPOSE OF

EXISTING CONCRETE OR

METAL PIPE (ALL SIZE)

PRESERVE AND PROTECT

EXISTING TREES

LEGEND

OH

H

O H

X

OH OH OH

PIPE-1 PIPE-1

PIPE-1 PIPE-1

PIPE-2 PIPE-2

SAN SAN SAN

GAS GAS GASSS

SS

SS

12+00 13+00

HCFCD ROW

HCFCD ROW

EXIST TOE OF SLOPE

EXIST TOP OF BANK

EXIST TOE OF SLOPE

EXIST TOP OF BANK

SCA

CTW

OH OH OHOH OH

OH OH

O H

O H

OH OH

G

AS

G

AS

GAS GAS GAS GAS GAS

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1

PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2

SANSAN SAN SAN

SS

SS

SANGAS

G

AS

37+00 38+00 39+00

HCFCD ROW

HCFCD ROWEXIST TOE OF SLOPE

EXIST TOP OF BANK

EXIST TOE OF SLOPE

EXIST TOP OF BANK

SCA

SCA

CTWSCACTW

SCA

X

X

X

OHOH OH

OH

O H

O H

OH OHOH OH OH OH

SSSS

SS SS

SSSS

SS SS

GAS GAS GAS GAS GAS GAS GAS

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1

PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2

SAN

26+00 27+00 28+00

HCFCD ROW

HCFCD ROW

EXIST TOE OF SLOPE

EXIST TOP OF BANK

EXIST TOE OF SLOPE

EXIST TOP OF BANK

SCA

SCA

SCA

SCA

CTW CTW

Houston, Texas 77092 9900 Northwest Freeway

SHEET NUMBER

DATE:

PR

EP

AR

ED

C H

EC

KE

D

AP

PR

O

VE

D

OF

C H

EC

KE

D

AP

PR

O

VE

D

R

EV

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

ST

ATE OF TEXAS

PROFESS IONAL ENGIN

EE

RL I CENSED

H C

FC

D

P R

O

JE

C T

ID

P1

-0 9-

-X

C O

N C

R

ET

E C

H

AN

N

EL

R

EP

AI

R

H C

FC

D

U N

IT

P1

-0 9-

11750 Katy Freeway, Suite 1260 Houston, TX 77079

800.414.1045

P:

\2

3\

.0 1_

CO

H

CO

NC

RE

TE

L

IN

IN

G\

DR

AW

IN

GS

\S

HE

ET

S\

3_

AC

CE

SS

P

LA

N.

DW

G

S

AV

ED

: M on da y, Ja nu ar y 1

9, 5:

:3

PM |

H

CF

CD

_1 1X

_N

CS

F

IN

AL

LO

TT

ED

: Th ur sd ay , F eb ru ar y 1

9, :3

0:

A M

SCALE:

AC

C

ES

S

PL

AN

SB PG N

W

FEB. 2026

AS SHOWN

10 42

0' 10' 20' 40'

SCALE:1 BIGWOOD STREET ACCESS

HORIZ: 1" = 40'

SCALE:3 GLEASON ROAD ACCESS

HORIZ: 1" = 40'

SCALE:2 PARKER ROAD ACCESS

HORIZ: 1" = 40'

BI

G

W O

O D

S

TR

EE

T

20' TEMPORARY

ACCESS ESMT

PAR

KER

R O

AD

10' TEMPORARY

ACCESS ESMT

G

LE

AS

O

N R

O

AD

10' TEMPORARY

ACCESS ESMT

20' TEMPORARY

ACCESS ESMT

10' TEMPORARY

ACCESS ESMT

20' TEMPORARY

ACCESS ESMT

20' TEMPORARY

ACCESS ESMT

10' TEMPORARY

ACCESS ESMT

20' TEMPORARY

ACCESS ESMT

10' TEMPORARY

ACCESS ESMT

STABILIZED

CONSTRUCTION ACCESS

CONCRETE TRUCK WASHOUT

(AS DIRECTED BY THE

ENGINEER)

TEMPORARY ACCESS

EASEMENT

SCA

LEGEND

PROPOSED RIPRAP

GRADATION NO 2

PROPOSED 8" THICK CONC

CHANNEL LINING

OH

H

OH OH OH OH OH OH OH OH

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1

PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2

SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SANGAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS

SS

12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00

BI

G

W O

O D

S

TR

EE

T

HCFCD ROW

HCFCD ROWCHEVRON PIPELINE

MAGELLAN PIPELINE CO. LP

EXIST TOE OF SLOPE

EXIST HIGH BANK

EXIST TOE OF SLOPE

EXIST HIGH BANK

CAUTION!!!

OVERHEAD

ELECTRIC LINE

CAUTION!!!

UNDERGROUND

GAS LINE

12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00

FD

-2

PROP HIGH BANK

PROP HIGH BANK

10' UTILITY ESMT

VOL 46, PG 9 HCMR

60' TEXAS PIPELINE

COMPANY ROW

VOL 2471, PGS 547 & 550,

HCDR

10' UTILITY ESMT

VOL 46, PG 9 HCMR

HCFCD UNIT NO P118-09-00

40' DRAINAGE ESMT

VOL 46, PG 9, HCMR

VOL. 46, PG 9, HCMR

SCENIC WOODS

VOL. 46, PG 9, HCMR

SCENIC WOODS

VOL. 46, PG 9, HCMR 10' TEMPORARY

ACCESS ESMT

20' TEMPORARY

ACCESS ESMT

SCA CTW

OHOH OH

O H

OHOH OH OH OH OH OH OH

SS

SS

SS

SS

GAS GAS GAS GAS GAS GAS

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1

PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2

SANSAN SAN SAN SAN SAN SANGAS GAS GAS GAS GAS

20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 28+00

PAR

KER

R O

AD

HCFCD ROW

MAGELLAN PIPELINE CO LP

CHEVRON PIPELINE CO LP

EXIST HIGH BANK

EXIST TOE OF SLOPE

CAUTION!!!

OVERHEAD

ELECTRIC LINE

CAUTION!!!

UNDERGROUND

GAS LINE

HCFCD ROW

HCFCD ROW

EXIST HIGH BANK

EXIST TOE OF SLOPE

EXIST HIGH BANK

EXIST TOE OF SLOPE

20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 28+00

PROP HIGH BANK

PROP HIGH BANK

HCFCD UNIT NO P118-09-00

40' DRAINAGE ESMT

VOL 46, PG 9, HCMR

VOL. 46, PG 9, HCMR

SCENIC WOODS

VOL. 46, PG 9, HCMR

10' UTILITY ESMT

VOL 46, PG 9 HCMR

60' TEXAS PIPELINE

COMPANY ROW

VOL 2471, PGS 547 & 550,

HCDR

10' UTILITY ESMT

VOL 46, PG 9 HCMR

SCENIC WOODS

VOL. 46, PG 9, HCMR 10' TEMPORARY

ACCESS ESMT

20' TEMPORARY

ACCESS ESMT

SCA

SCA

SCA

SCA

CTW CTW

Houston, Texas 77092 9900 Northwest Freeway

SHEET NUMBER

DATE:

PR

EP

AR

ED

C H

EC

KE

D

AP

PR

O

VE

D

OF

C H

EC

KE

D

AP

PR

O

VE

D

R

EV

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

ST

ATE OF TEXAS

PROFESS IONAL ENGIN

EE

RL I CENSED

H C

FC

D

P R

O

JE

C T

ID

P1

-0 9-

-X

C O

N C

R

ET

E C

H

AN

N

EL

R

EP

AI

R

H C

FC

D

U N

IT

P1

-0 9-

11750 Katy Freeway, Suite 1260 Houston, TX 77079

800.414.1045

P:

\2

3\

.0 1_

CO

H

CO

NC

RE

TE

L

IN

IN

G\

DR

AW

IN

GS

\S

HE

ET

S\

5_

ST

OR

M W

AT

ER

P

OL

LU

TI

ON

P

RE

VE

NT

IO

N

PL

AN

.D

W G

S

AV

ED

: M on da y, Ja nu ar y 1

9, 5:

:5

PM |

H

CF

CD

_1 1X

_N

CS

F

IN

AL

LO

TT

ED

: Th ur sd ay , F eb ru ar y 1

9, :3

1:

A M

SCALE:

ST

O

R M

W

AT

ER

P

O

LL

U

TI

O N

P R

EV

EN

TI

O

N P

LA

N

(1 O

F 2)

SB PG N

W

FEB. 2026

AS SHOWN

11 42

0' 30' 60'

B

EG

IN

P

R O

JE

C

T

ST

A . 1

1+

M A

TC

H

L

IN

E S

TA

. 2

0+

(S

EE

T H

IS

S

H

EE

T) M

A

TC

H L

IN

E

S

TA

. 2 8+

(S

EE

S

H

EE

T

M A

TC

H

L

IN

E S

TA

. 2

0+

(S

EE

T H

IS

S

H

EE

T)

REINFORCED SILT FENCE

STABILIZED

CONSTRICTION ACCESS

TYPE 2 (REINFORCED)

FILTER DAM

HYDROMULCH

TURFGRASS SEEDING

CONCRETE TRUCK WASHOUT

(AS DIRECTED BY THE

ENGINEER)

TEMPORARY ACCESS

EASEMENT

RSF

SCA

LEGEND

PROPOSED RIPRAP

GRADATION NO 2

PROPOSED 8" THICK CONC

CHANNEL LINING

OH OH OH OH OH GAS GAS

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1

PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2

SAN SAN SAN SAN SAN SAN SAN SANGAS GAS GAS GAS GAS

29+00 30+00 31+00 32+00 33+00 34+00 35+00

CHEVRON PIPELINE

MAGELLAN PIPELINE CO. LP

HCFCD ROW

HCFCD ROW

EXIST HIGH BANK

EXIST TOE OF SLOPE

EXIST HIGH BANK

EXIST TOE OF SLOPE

CAUTION!!!

OVERHEAD

ELECTRIC LINE

CAUTION!!!

UNDERGROUND

GAS LINE

29+00 30+00 31+00 32+00 33+00 34+00 35+00

PROP HIGH BANK PROP HIGH BANK

HCFCD UNIT NO

P118-09-00

40' DRAINAGE ESMT

VOL 46, PG 9, HCMR

SCENIC WOODS

VOL. 46, PG 9, HCMR

10' UTILITY ESMT

VOL 46, PG 9 HCMR

60' TEXAS PIPELINE

COMPANY ROW

VOL 2471, PGS 547 &

550, HCDR

10' UTILITY ESMT

VOL 46, PG 9 HCMR

SCENIC WOODS

VOL. 46, PG 9, HCMR10' TEMPORARY

ACCESS ESMT

20' TEMPORARY

ACCESS ESMT

PROP HIGH BANK

OH OH OHOH

OH

O

H

OH

G

AS

GAS GAS GAS GAS GAS

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1

PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2

SAN SAN SAN SAN

SS

G

AS

35+00 36+00 37+00 38+00 39+00 40+00

G

LE

AS

O

N R

O

AD

CHEVRON PIPELINE

MAGELLAN PIPELINE CO. LP

HCFCD ROW

HCFCD ROW

EXIST HIGH BANK

EXIST TOE OF SLOPE

EXIST HIGH BANK

EXIST TOE OF SLOPE

EXIST HIGH BANK

EXIST TOE OF SLOPE

EXIST HIGH BANK

CAUTION!!!

OVERHEAD

ELECTRIC LINE

CAUTION!!!

UNDERGROUND

GAS LINE

HCFCD ROW

HCFCD ROW

35+00 36+00 37+00 38+00 39+00 40+00

PROP HIGH BANK

10' UTILITY ESMT

VOL 46, PG 9 HCMR

60' TEXAS PIPELINE

COMPANY ROW

VOL 2471, PGS 547 &

550, HCDR

10' UTILITY ESMT

VOL 46, PG 9 HCMR

HCFCD UNIT NO P118-09-00

40' DRAINAGE ESMT

VOL 46, PG 9, HCMR

SCENIC WOODS

VOL. 46, PG 9, HCMR

SCENIC WOODS

VOL. 46, PG 9, HCMR

10' TEMPORARY

ACCESS ESMT

PROP HIGH BANK EXIST TOE OF SLOPE

20' TEMPORARY

ACCESS ESMT

SCA

SCA

SCA CTWCTW

SCA

Houston, Texas 77092 9900 Northwest Freeway

SHEET NUMBER

DATE:

PR

EP

AR

ED

C H

EC

KE

D

AP

PR

O

VE

D

OF

C H

EC

KE

D

AP

PR

O

VE

D

R

EV

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

ST

ATE OF TEXAS

PROFESS IONAL ENGIN

EE

RL I CENSED

H C

FC

D

P R

O

JE

C T

ID

P1

-0 9-

-X

C O

N C

R

ET

E C

H

AN

N

EL

R

EP

AI

R

H C

FC

D

U N

IT

P1

-0 9-

11750 Katy Freeway, Suite 1260 Houston, TX 77079

800.414.1045

P:

\2

3\

.0 1_

CO

H

CO

NC

RE

TE

L

IN

IN

G\

DR

AW

IN

GS

\S

HE

ET

S\

5_

ST

OR

M W

AT

ER

P

OL

LU

TI

ON

P

RE

VE

NT

IO

N

PL

AN

.D

W G

S

AV

ED

: M on da y, Ja nu ar y 1

9, 5:

:5

PM |

H

CF

CD

_1 1X

_N

CS

F

IN

AL

LO

TT

ED

: Th ur sd ay , F eb ru ar y 1

9, :3

1:

A M

SCALE:

ST

O

R M

W

AT

ER

P

O

LL

U

TI

O N

P R

EV

EN

TI

O

N P

LA

N

(2 O

F 2)

SB PG N

W

FEB. 2026

AS SHOWN

12 42

0' 30' 60'

(S

EE

T H

IS

S

H

EE

T) M

A

TC

H L

IN

E

S

TA

. 3 5+

M A

TC

H

L

IN

E S

TA

. 3

5+

(S

EE

T H

IS

S

H

EE

T)

EN

D

P R

O

JE

C T

ST

A

. 4 0+

(S

EE

S H

EE

T

N O

. 8

M A

TC

H

L

IN

E S

TA

. 2

9+

REINFORCED SILT FENCE

STABILIZED

CONSTRICTION ACCESS

HYDROMULCH

TURFGRASS SEEDING

CONCRETE TRUCK WASHOUT

(AS DIRECTED BY THE

ENGINEER)

TEMPORARY ACCESS

EASEMENT

RSF

SCA

LEGEND

PROPOSED RIPRAP

GRADATION NO 2

PROPOSED 8" THICK CONC

CHANNEL LINING

TYPE 2 (REINFORCED)

FILTER DAM

0+35 0+40 0+50 0+60 0+70 0+80 0+90 1+00 1+10 1+20 1+30 1+40 1+50 1+60 1+65

HCFCD UNIT NO. P118-09-00

EXIST 40' DRAINAGE EASEMENT

VOL 46, PG 9 HCMR

EXIST 60' TEXAS PIPELINE COMPANY R.O.W.

VOL 2471, PGS 547 & 550 HCMR

8" THICK

CHANNEL LINING

EXIST GROUND

TOE WALL

MATCH

EXISTING

1:1

1:1

8" THICK

CHANNEL LINING

1' TOE WALL

3'

1' 2'

3:1 4:1

MATCH

EXISTING

4'

RIPRAP GRADATION NO. 2

(24" THICK)

GRASS-LINEGRASS-LINE

2'

H C

FC

D

R O

W

PR

O

PE

R

TY

L

IN

E

PR

O

PE

R

TY

L

IN

E

10' UTILITY EASEMENT

VOL 46, PG9 HCMR

H C

FC

D

R O

W / E

SM

T

LI

N

E

10' UTILITY EASEMENT

VOL 46, PG9 HCMR

U

TI

LI

TY

E

SM

T

LI

N E

U

TI

LI

TY

E

AS

EM

EN

T

LI

N E

1'

2'

2'

DTL

DTL

0+35 0+40 0+50 0+60 0+70 0+80 0+90 1+00 1+10 1+20 1+30 1+40 1+50 1+60 1+65

MATCH

EXISTING

1:1

1:1

8" THICK

CHANNEL LINING

EXIST GROUND

TOE WALL

8" THICK

CHANNEL LINING

1'

TOE WALL

3'

1' 2'

MATCH

EXISTING

2:1 3:1

RIPRAP GRADATION NO. 2

(24" THICK)

GRASS-LINE GRASS-LINE

4'

2'

EXIST. 60' TEXAS PIPELINE COMPANY R.O.W.

VOL 2471, PGS 547 & 550 HCMR

HCFCD UNIT NO. P118-09-00

EXIST 40' DRAINAGE EASEMENT

VOL 46, PG 9 HCMR

H

C

FC

D R

O W

PR

O

PE

R

TY

L

IN

E

PR

O

PE

R

TY

L

IN

E

H C

FC

D

R O

W / E

SM

T

LI

N

E

10' UTILITY EASEMENT

VOL 46, PG9 HCMR

10' UTILITY EASEMENT

VOL 46, PG9 HCMR

U

TI

LI

TY

E

SM

T

LI

N E

U

TI

LI

TY

E

SM

T

LI

N E

1'

2'

2'

DTL

DTL

Houston, Texas 77092 9900 Northwest Freeway

SHEET NUMBER

DATE:

PR

EP

AR

ED

C H

EC

KE

D

AP

PR

O

VE

D

OF

C H

EC

KE

D

AP

PR

O

VE

D

R

EV

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

ST

ATE OF TEXAS

PROFESS IONAL ENGIN

EE

RL I CENSED

H C

FC

D

P R

O

JE

C T

ID

P1

-0 9-

-X

C O

N C

R

ET

E C

H

AN

N

EL

R

EP

AI

R

H C

FC

D

U N

IT

P1

-0 9-

11750 Katy Freeway, Suite 1260 Houston, TX 77079

800.414.1045

P:

\2

3\

.0 1_

CO

H

CO

NC

RE

TE

L

IN

IN

G\

DR

AW

IN

GS

\S

HE

ET

S\

6_

TY

PI

CA

L

SE

CT

IO

NS

.D W

G

S

AV

ED

: W ed ne sd ay

, J an ua ry

4, 2:

:1

PM |

H

CF

CD

_1 1X

_N

CS

F

IN

AL

LO

TT

ED

: Th ur sd ay , F eb ru ar y 1

9, :3

1:

A M

SCALE:

TY

PI

C

AL

S

EC

TI

O

N S

SB PG N

W

FEB. 2026

AS SHOWN

13 42

SCALE:1 TYPICAL SECTION (STA. 11+50 TO STA. 26+00)

HORIZ: 1" = 10' VERT: 1" = 10'

SCALE:2 TYPICAL SECTION (STA. 27+50 TO STA. 37+50)

HORIZ: 1" = 10' VERT: 1" = 10'

NOTES

1. REFER TO SHEET NO 36

FOR INFORMATION ON

THE CHANNEL LINING

SECTION DETAIL.

2. CONTRACTOR SHALL

GRADE EXISTING

GROUND TO DRAIN IN

THE 10-FT EASEMENT.

0.3%

EXIST GROUND

EXIST RT HIGH BANK

EXIST LT HIGH BANK

EXIST DUAL

60" RCP

BIGWOOD STREET

P118-09-00 CENTERLINE

11+50 12+00 13+00 14+00 15+00 15+80

ELEV=38.15

EXIST 36" RCP

EXIST 8" WL

TOP OF CHANNEL LINING

ELEV=45.83

TOP OF CHANNEL

LINING

ELEV=44.85

EXIST 8" WL

6" MIN CLEARANCE FROM EXIST 60"

RCP (PER COH DWG# 36047)

PROP RIPRAP GRADATION NO. 2

PROP CHANNEL FLOW LINE

PROP LT HIGH BANK

PROP RT HIGH BANK

PROP CHANNEL LINING

PROP CONCRETE

CHANNEL LINING

PROP HEADWALL

SEE SHEET NO 38

OH

O H

O H

X

OH OH OH OH OH OH OH OH

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1

PIPE-1 PIPE-1

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1

PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2

SAN SAN SAN SAN SAN SAN SAN SAN SAN

GAS GAS GAS GAS GAS GAS GAS GASSS

SS

SS

10' UTILITY ESMT

VOL 46, PG 9 HCMR

60' TEXAS PIPELINE

COMPANY ROW

VOL 2471, PGS 547 & 550

HCMR

10' UTILITY ESMT

VOL 46, PG 9 HCMR

HCFCD ROW

HCFCD ROW

EXIST TOP OF BANK

EXIST TOP OF BANK

EXIST TOE OF SLOPE

19' CHANNEL WIDTH

CAUTION!!!

OVERHEAD

ELECTRIC LINE

CHEVRON PIPELINE

MAGELLAN PIPELINE CO. LP

CAUTION!!!

UNDERGROUND

GAS LINE

CNP 2" IP STL GAS LINE

EXIST OVERHEAD ELEC

EXIST 36" RCP

EXIST WOOD FENCE

EXIST OVERHEAD ELEC

EXIST CHAINLINK FENCE

EXIST FIBEROPTIC BOX

ABANDONED 8" CI WL

(PER SUE )

EXIST PIPE FENCE

EXIST 6' WOOD FENCE

FLOW

EXIST GUARDRAIL

EXIST 60" RCP

EXIST 60" RCP

EXIST 10" EXPOSED PIPE

HCFCD UNIT NO P118-09-00

40' DRAINAGE ESMT

VOL 46, PG 9, HCMR

BI

G

W O

O D

ST

R

EE

T

12+00 13+00 14+00 15+00 16+00

EXIST SAN

SWR MH

ABANDONED 16" FM

ABANDONED 16" FMABANDONED FM MH

EXIST 8" WL

CNP 2" IP STL GAS LINE

EXIST 8" SAN SWR

P118-09-00

PROP TOE OF SLOPE

PROP HIGH BANK

PROP TOE OF SLOPE

PROP HIGH BANK

PROP TOP OF CHANNEL

PROP BOTTOM

OF CHANNEL

PROP TOP OF CHANNEL

PROP BOTTOM

OF CHANNEL

PROP RIPRAP

GRADATION NO.

2 (24" THICK)

BEGIN PROJECT

STA 12+00

N: 13879413.58 E: 3143969.48

PROP HEADWALL

SEE SHEET NO 38

1 - 8" CUT PLUG AND

ABANDONED

1 - 8" CUT PLUG AND

ABANDONED

PROP 560 LF OF TEMPORARY

ACCESS MATTING

EXIST TOE OF SLOPE

M

AT

C H

L

IN

E

ST

A

+8

(S

EE

S H

EE

T

0'

SCALE: HORZ:

VERT: 1" = 4'

1" = 40'

40'20'10'

Houston, Texas 77092 9900 Northwest Freeway

SHEET NUMBER

DATE:

PR

EP

AR

ED

C H

EC

KE

D

AP

PR

O

VE

D

OF

C H

EC

KE

D

AP

PR

O

VE

D

R

EV

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

ST

ATE OF TEXAS

PROFESS IONAL ENGIN

EE

RL I CENSED

H C

FC

D

P R

O

JE

C T

ID

P1

-0 9-

-X

C O

N C

R

ET

E C

H

AN

N

EL

R

EP

AI

R

H C

FC

D

U N

IT

P1

-0 9-

11750 Katy Freeway, Suite 1260 Houston, TX 77079

800.414.1045

P:

\2

3\

.0 1_

CO

H

CO

NC

RE

TE

L

IN

IN

G\

DR

AW

IN

GS

\S

HE

ET

S\

1_

PL

AN

P

RO

FI

LE

.D

W G

S

AV

ED

: W ed ne sd ay , F eb ru ar y 1

8, 4:

:5

PM |

H

CF

CD

_1 1X

_N

CS

F

IN

AL

LO

TT

ED

: Th ur sd ay , F eb ru ar y 1

9, :3

1:

A M

SCALE:

PL

AN

P

R O

FI

LE

(1 O

F 6)

SB PG N

W

FEB. 2026

AS SHOWN

14 42

LEGEND

PROPOSED 8" THICK CONC

CHANNEL LINING

PROPOSED RIPRAP

GRADATION NO 2

PROPOSED GRASS LINED

AREA

PROPOSED TOP OF SLOPE

PROPOSED TOE OF SLOPE

NOTES

1. CONTRACTOR SHALL GRADE INSIDE THE 10-FT

EASEMENT TO PROVIDE POSITIVE DRAINAGE

TOWARDS THE CHANNEL WHEN APPLICABLE.

2. EQUIPMENT MUST OPERATE WITHIN 10-FEET OF

THE HCFCD RIGHT-OF-WAY AND NO FURTHER. IF

THE CONTRACTOR NEEDS TO OPERATE

EQUIPMENT ON THE TEMPORARY ACCESS MATS,

THEN THEY WILL OPERATE SOLELY ON THE

MATS AND NOT LEAVE THEM AT ANY TIME.

3. CONTRACTOR TO PROVIDE TEMPORARY

ACCESS MATS AS NOTED IN THE PLANS AND AS

DIRECTED BY THE MAGELLAN PIPELINE

REPRESENTATIVE FOR THE DURATION OF THE

PROJECT.

TEMPORARY ACCESS MATS

(MIN. DIMENSION OF 16'X4'X8")

OH OH OHOH OH OH OH OH OH OH

CP-1006

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1

PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2

SAN SAN SAN SAN SAN SAN SAN SAN SAN SANGAS GAS GAS GAS GAS GAS GAS GAS GAS GAS

EXIST TREE LINE

10' UTILITY ESMT

VOL 46, PG 9 HCMR

60' TEXAS PIPELINE

COMPANY ROW

VOL 2471, PGS 547 & 550

HCMR

10' UTILITY ESMT

VOL 46, PG 9 HCMR

HCFCD ROW

EXIST TOE OF SLOPE

EXIST HIGH BANK

EXIST TOE OF SLOPE

EXIST HIGH BANK

HCFCD ROW

19' CHANNEL WIDTH

CHEVRON PIPELINE

MAGELLAN PIPELINE CO. LP

CAUTION!!!

OVERHEAD

ELECTRIC LINECAUTION!!!

UNDERGROUND

GAS LINE

EXIST OVERHEAD ELEC

FLOW

EXIST OVERHEAD ELEC

CNP 2" IP STL GAS LINE

EXIST CHAINLINK FENCE

EXIST CHAINLINK FENCE

CNP 2" IP STL GAS LINEEXIST SAN

SWR MH

EXIST WOOD FENCE

EXIST WOOD FENCE

HCFCD UNIT NO P118-09-00

40' DRAINAGE ESMT

VOL 46, PG 9, HCMR

16+00 17+00 18+00 19+00 20+00

ABANDONED 16" FM

EXIST 8" SAN SWR

ABANDONED 16" FM

EXIST 8" SAN SWRPROP HIGH BANK

PROP HIGH BANK

PROP TOE OF SLOPE

PROP TOE OF SLOPE

PROP TOP OF CHANNEL

PROP BOTTOM

OF CHANNEL

PROP TOP OF CHANNEL

PROP BOTTOM

OF CHANNEL PROP RIPRAP

GRADATION NO. 2

P118-09-00

PROP 560 LF OF TEMPORARY

ACCESS MATTING

M

AT

C H

L

IN

E

ST

A

+8

(S

EE

S H

EE

T

M

AT

C H

L

IN

E

ST

A

+4

(S

EE

S H

EE

T

P118-09-00 CENTERLINE

15+80 16+00 17+00 18+00 19+00 20+00 20+40

0.3%

EXIST GROUND

EXIST RT HIGH BANK

EXIST LT HIGH BANK

EXIST 18" RCP

PROP RT HIGH BANK

PROP LT HIGH BANK

PROP CHANNEL FLOW LINE

PROP CONCRETE

CHANNEL LINING

PROP RIPRAP GRADATION NO. 2

Houston, Texas 77092 9900 Northwest Freeway

SHEET NUMBER

DATE:

PR

EP

AR

ED

C H

EC

KE

D

AP

PR

O

VE

D

OF

C H

EC

KE

D

AP

PR

O

VE

D

R

EV

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

ST

ATE OF TEXAS

PROFESS IONAL ENGIN

EE

RL I CENSED

H C

FC

D

P R

O

JE

C T

ID

P1

-0 9-

-X

C O

N C

R

ET

E C

H

AN

N

EL

R

EP

AI

R

H C

FC

D

U N

IT

P1

-0 9-

11750 Katy Freeway, Suite 1260 Houston, TX 77079

800.414.1045

P:

\2

3\

.0 1_

CO

H

CO

NC

RE

TE

L

IN

IN

G\

DR

AW

IN

GS

\S

HE

ET

S\

1_

PL

AN

P

RO

FI

LE

.D

W G

S

AV

ED

: W ed ne sd ay , F eb ru ar y 1

8, 4:

:5

PM |

H

CF

CD

_1 1X

_N

CS

F

IN

AL

LO

TT

ED

: Th ur sd ay , F eb ru ar y 1

9, :3

2:

A M

SCALE:

PL

AN

P

R O

FI

LE

(2 O

F 6)

SB PG N

W

FEB. 2026

AS SHOWN

15 42

0'

SCALE: HORZ:

VERT: 1" = 4'

1" = 40'

40'20'10'

LEGEND

PROPOSED RIPRAP

GRADATION NO 2

PROPOSED GRASS LINED

AREA

PROPOSED TOP OF SLOPE

PROPOSED TOE OF SLOPE

PROPOSED 8" THICK CONC

CHANNEL LINING

NOTES

TEMPORARY ACCESS MATS

1. CONTRACTOR SHALL GRADE INSIDE THE

10-FT EASEMENT TO PROVIDE POSITIVE

DRAINAGE TOWARDS THE CHANNEL

WHEN APPLICABLE.

2. EQUIPMENT MUST OPERATE WITHIN

10-FEET OF THE HCFCD RIGHT-OF-WAY

AND NO FURTHER. IF THE CONTRACTOR

NEEDS TO OPERATE EQUIPMENT ON THE

TEMPORARY ACCESS MATS, THEN THEY

WILL OPERATE SOLELY ON THE MATS

AND NOT LEAVE THEM AT ANY TIME.

3. CONTRACTOR TO PROVIDE TEMPORARY

ACCESS MATS AS NOTED IN THE PLANS

AND AS DIRECTED BY THE MAGELLAN

PIPELINE REPRESENTATIVE FOR THE

DURATION OF THE PROJECT.

(MIN. DIMENSION OF 16'X4'X8")

OH OH OH OH OH OH OH OH OH

CP-1002

GAS GAS GAS

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1

PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1 PIPE-1

PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2 PIPE-2

SANSAN SAN SAN SAN SAN SAN SAN SAN SAN

GAS GAS GAS GAS GAS GAS GAS

10' UTILITY ESMT

VOL 46, PG 9 HCMR

60' TEXAS PIPELINE

COMPANY ROW

VOL 2471, PGS 547 & 550

HCMR

10' UTILITY ESMT

VOL 46, PG 9 HCMR

HCFCD ROW

HCFCD ROW

CAUTION!!!

OVERHEAD

ELECTRIC LINE

EXIST HIGH BANK

EXIST TOE OF SLOPE

EXIST HIGH BANK

EXIST TOE OF SLOPE

MAGELLAN PIPELINE CO LP

CHEVRON PIPELINE

19' CHANNEL WIDTH

CAUTION!!!

UNDERGROUND

GAS LINE

FLOW

CNP 2" IP STL GAS LINE

EXIST CHAINLINK FENCE EXIST WOOD FENCEEXIST SAN SWR MH

EXIST 18" RCP

EXIST CHAINLINK FENCE

EXIST OVERHEAD ELEC

EXIST WOOD FENCE

HCFCD UNIT NO P118-09-00

40' DRAINAGE ESMT

VOL 46, PG 9, HCMR

21+00 22+00 23+00 24+00 25+00

EXIST 8" SAN SWR

ABANDONED 16"…