2-Figure 1 Grant Road Demolition Plan.pdf
PDF 277 KB Posted
- Attached to
- Elevated Storage Tanks Removal
- Solicitation number
- 2026-PME-06
- Issued by
- Clayton County, Georgia
About this file
This is a demolition plan document prepared by HDR Engineering, Inc. for the Clayton County Water Authority (CCWA) regarding the removal of an elevated storage tank located at 4342 Grant Road, Ellenwood, Georgia. The project involves the demolition of a 1.0 million gallon elevated steel storage tank with an overall height of 160 feet from pier to overflow. The site encompasses 0.69 acres (30,170 square feet) and is bounded by Grant Road and Anvil Block Road, with the property owned by Walmart Real Estate Business Trust. Key demolition requirements include removal of the water tower to foundation level, removal of fill, drain, and overflow piping to the first mechanical joint in the ground vault, capping of concrete openings with aluminum diamond plate covers sealed with exterior-grade silicone sealant, and removal of any antennas or communication equipment. The plan specifies that Grant Road and the road entrance must remain closed during active demolition activity, and contractors are required to field verify tank dimensions and remove fencing as needed for access.
The demolition plan references Specification Sections 01 11 00 (Summary of Work) and 02 41 00 (Demolition) for detailed demolition requirements and contractor obligations. This project is part of a larger CCWA initiative to remove two elevated storage tanks, with a second tank (0.5 million gallon) located at 101 Barnett Road, Forest Park, Georgia. The plan was prepared by project manager Kristina Yanosek with a project date of November 13, 2025, and project number 10413963CCWA. The document includes a site elevation detail and photograph reference to support contractor understanding of the existing tank conditions and site configuration.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
XX
X X
X
X X
X X
X
GR
AN
T
RO
AD
(8
0' R/
W
(P
ER
P B
PG
7)
N89°24'28"W 174.79'
FENCE
CMF
CMF
UP
OHE
WV
FH
POB: CMF
UP
SHED
SIDEWALK
POC: 520' ± FROM CONCRETE
MONUMENT FOUND AT THE
NORTHWEST CORNER OF
MITERED INTERSECTION OF
GRANT ROAD AND ANVIL BLOCK
ROAD
POWER PANEL ON
CONCRETE
UP
FH
VALVE HOUSE
STAIRS
WALL
A=175.40' R=1495.50' N04°02'47"W Lc=175.30'
WATER TOWER
LEG, TYP.
OHE
OHE
TE TE
TE
TE
TE
TE
TE
TETE
TE
TE
TE
N/F
ERIC ZORN AS TRUSTEE OF
WALMART REAL ESTATE BUSINESS
TRUST C/O WALMART INC.
PARCEL# 122235B A043
DB 9503 - PG 484
S0 4°
'21
"E
5.2 5'
CMF
CMF
FE
NC
E
TOTAL AREA:
0.69 ACRES
(30,170 SQ. FT.)
ROAD AND ROAD
ENTRANCE TO REMAIN
CLOSED DURING ACTIVE
DEMOLITION ACTIVITY
FENCE
DEMOLISH WATER
TOWER TO FOUNDATION
12'' DIP
CP
CP, TYP.
S89°22'21"E 174.11'
6'
135'
1.7
113'
SHEET TITLE
PROJECT TITLE
PROJECT MANAGER
DATE
PROJECT NUMBER
REFERENCE DOCUMENT
EXHIBIT NUMBER
REFERENCE SHEET
HDR Engineering, Inc.
1100 Peachtree Street NE Suite 400 Atlanta, GA 30309-4053 404.601.8600
KRISTINA YANOSEK
11-13-2025
10413963CCWA ELEVATED STORAGE TANK DEMOLITION
0 1" 2"
1" = 70'
TANK ELEVATION (N.T.S)
DETAIL 1
PHOTO OF GRANT ROAD ELEVATED
STORAGE TANK SITE
DETAIL 2
TOP OF FOUNDATION
EL. 946'
OV
ER
AL
L H
EI
GH
T, P
IE
R
TO
O
VE
RF
LO
W
0.0 0'
ABBREVIATIONS & LEGEND
PROPERTY BOUNDARY
DEMOLITION
OHE OVERHEAD ELECTRIC
TE TEMPORARY EASEMENT
WATER VALVE
CONCRETE MONUMENT FOUND
CONCRETE PAD
UTILITY POLE
WV
CMF
CP
UP
1. REFER TO SPECIFICATION SECTION 01 11 00 - SUMMARY OF WORK AND SPECIFICATION SECTION
02 41 00 - DEMOLITION FOR DEMOLITION REQUIREMENTS.
2. SEE DETAIL 1 FOR TANK DIMENSIONS. CONTRACTOR TO FIELD VERIFY.
3. CONTRACTOR TO REMOVE FENCE AS NEEDED FOR ACCESS.
4. FILL, DRAIN AND OVERFLOW PIPING THAT EXIST IN THE CENTER RISER SHALL BE REMOVED TO THE FIRST MECHANICAL JOINT SITUATED ON PIPE IN THE GROUND VAULT BELOW RISE. CONCRETE
OPENINGS SHALL BE COVERED WITH ¼-INCH THICK ALUMINUM DIAMOND PLATE SECURED BY
3/8-INCH STAINLESS STEEL WEDGE ANCHORS WITH WASHERS. ALUMINUM COVER SHALL BE
SEALED TO CONCRETE USING EXTERIOR GRADE SILICONE SEALANT.
5. THERE IS NOT ACTIVE COMMUNICATION EQUIPMENT ON TANK, CONTRACTOR TO DEMOLISH ANY
ANTENNA OR APPURTENANCES AS NEEDED.
FIRE HYDRANT
NOTES
FH
POINT OF BEGINNINGPOB
BO
W
L H
EI
GH
T
.00
GRANT ROAD DEMOLITION PLAN
FIGURE 1
File details come from the government source that posted it. Updated .