2. 570-21-108_VA Fresno Exterior Drawings.pdf
PDF 37 MB Posted
- Solicitation number
- 36C26126R0034
About this file
This file comprises architectural and engineering design drawings and specifications for the Repair Exterior Finishes, Building 1 and OPC project (570-21-108) at the Fresno VA Medical Center in Fresno, California. The project scope encompasses multiple distinct work phases: (1) building envelope repairs including non-abrasive cleaning, terra cotta restoration, stucco repairs, concrete spall remediation, and fenestration restoration across 92,822 square feet of exterior facades; (2) glazing replacement of single-glazed windows and storefronts with double-glazing units across 1,175 square feet; (3) roof repairs of lower roof areas of the OPC and west wing of Building 1 covering 20,444 square feet; (4) installation of new stair access from OPC to Building 1 Chapel Roof with platform framing and fiberglass grating; (5) renovation of three entrance vestibules (north, east, and south) including demolition of existing enclosures and installation of new automatic insulated-glass sliding doors with motion detection sensors; (6) complete OPC ballast roof replacement covering 11,676 square feet with single-ply roofing system; and (7) Building 1 west wing and chapel roof replacement covering 28,108 square feet. The base contract period of performance is 330 calendar days from Notice to Proceed, with three additional work alternates having separate performance periods. All work must comply with 2021 IBC and 2022 CBC building codes, VA design standards, and NFPA fire safety standards. The work is designated as Design-Build and requires coordination with ongoing facility operations as the medical center remains occupied and operational throughout construction, with specific infection control (ICRA) and dust control measures mandated.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C26126R0034 0004.docx | DOCX document | |
| DBA WD CA20260018 dated 5_18_2026.pdf | ||
| 36C26126R0034 0003.docx | DOCX document | |
| VA Fresno ACM Survey.pdf | ||
| RFI Responses Repair Ext. Finishes FRE.pdf | ||
| 36C26126R0034 0002.docx | DOCX document | |
| Site Visit Sign-in 570-21-108_.pdf | ||
| 36C26126R0034 0001.docx | DOCX document | |
| 1. 570-21-108 Specifications.pdf | ||
| 6. DBA WD CA20260018 dtd 1 30 2026.pdf | ||
| 5. Pre-Proposal Site Visit Information.pptx | PPTX presentation | |
| 3. Requests for Information RFI_ Form.docx | DOCX document | |
| 36C26126R0034_2.docx | DOCX document | |
| 4. Price Breakdown Worksheet.docx | DOCX document | |
| 7. Factor 2 Past Performance Questionnaire.docx | DOCX document |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Architecture Engineering Design-Build paradigm
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% NOT FOR CONSTRUCTION
BID DOCUMENTS
Office of Construction &
Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT / ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
570-21-108VA CENTRAL CALIFORNIA HEALTH CARE SYSTEM
REPAIR EXTERIOR FINISHES BLDG 1 & OPC
2615 EAST CLINTON AVENUE
FRESNO, CA 93703-2223
1-23-2026
Project Director
9000 Wessex Place, Suite 202, Louisville, KY 40222 www.paradigmusa.com
FULLY SPRINKLERED
AR TL
1-23-2026
Au to de sk
D oc s:
//F
R E2
- F re sn o
R ep ai r E xt er io r F in is he s, B ui ld in g
O ut pa tie nt
/F R
E2
1- A
- V A
Fr es no E xt er io r.r vt 1/
/2
4:
:5
PM
G000
COVER SHEET
FRESNO VAMC REPAIR EXTERIOR FINISHES, BUILDING 1 & OPC
U.S. DEPARTMENT OF VETERANS AFFAIRS
VA PROJECT NO: 570-21-108
APN: 445-270-08
ADDRESS: 2615 CLINTON AVE, FRESNO CA 93703
SITE ACRES: 16.75
BUILDING AREA: 247,860 SF
GOVERNING AGENCY: UNITED STATES OF AMERICA, U.S. DEPT. OF VETERANS AFFAIRS
SCOPE OF WORK: SCOPE OF WORK IS LIMITED TO THE EXTERIOR FINISHES REPAIRS OF THE BUILDING, EXTERIOR GLAZING REPLACEMENT, AND ROOF REPLACEMENT. IT IS ENVISIONED THAT WORK INSIDE THE BUILDING WILL BE LIMITED TO ACCESS
TO THE EXTERIOR FACADE. THERE ARE NO CHANGES TO ANY USE WITHIN THE FACILITY.
REFER TO SHEET G002 FOR A DETAILED DESCRIPTION OF THE SCOPE OF WORK AND ADD ALTERNATES.
SCOPE 1 - BUILDING 1 AND OPC ENVELOPE REPAIRS | AREA OF EXTERIOR FACADES: 92,822 SF
SCOPE 2 - BUILDING 1, OPC, OPC 2 GLAZING | AREA OF DISTURBANCE: 1,175 SF
SCOPE 3 - ROOF REPAIR OF LOWER ROOF OF OPC & WEST WING OF BUILDING 1 | AREA OF REPAIR WORK: 20,444 SF SCOPE 4 - STAIR ACCESS FROM OPC TO BUILDING 1 CHAPEL ROOF | AREA OF DISTURBANCE: 10 SF SCOPE 5 - REPAIR STOREFRONT NORTH, SOUTH & EAST DEMOLITION VESTIBULE BUILDING 1 | AREA OF REPAIR WORK: 113 SF
SCOPE 6 - OPC BALLAST ROOF DEMOLITION | OPC ROOF AREA REPLACEMENT: 11676 SF
SCOPE 7 - BUILDING 1 WEST WING ROOF, BRIDGE ROOF & CHAPEL ROOF REPLACEMENT | WEST WING BLDG 1 ROOF AREA
REPLACEMENT: 16432 SF
BUILDING OCCUPANCY: I-2 HOSPITAL, B - OFFICE, OUTPATIENT CLINIC
CONSTRUCTION TYPE: I-A WITH AUTOMATIC FIRE SPRINKLERS
ALLOWABLE BUILDING AREA: UNLIMITED
ALLOWABLE BUILDING HEIGHT: UNLIMITED
1- THE INTENT OF THESE CONTRACT DRAWINGS ARE TO PRESCRIBE THE CONSTRUCTION AND COMPLETION OF THE WORK. WHERE THE CONTRACT DRAWINGS DESCRIBE PORTIONS OF THE WORK OR EQUIPMENT IN GENERAL TERMS, BUT NOT IN COMPLETE DETAILS OR REQUIRED HARDWARE OR DEVICES, THE BEST GENERAL PRACTICE SHALL BE FOLLOWED AND ONLY NEW MATERIAL AND WORKMANSHIP OF BEST STANDARD QUALITY SHALL BE USED, UNLESS OTHERWISE SPECIFIED. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, TOOLS, EQUIPMENT AND INCIDENTALS WHICH ARE NECESSARY TO COMPLETE THE WORK IN A
SUBSTANTIAL AND WORKMANLIKE WAY.
2- THE CONTRACTORS SHALL VISIT THE SITE PRIOR TO BIDDING AND FAMILIARIZE THEMSELVES WITH THE EXISTING CONDITION AND THE EXTENT OF THE WORK. THE CONTRACTORS SHALL VERIFY ALL EXISTING CONDITIONS SHOWN ON THE DRAWINGS.
REASONABLE ASSUMPTIONS SHALL BE MADE FOR ITEMS NOT CLEARLY VISIBLE AND COST SHALL BE INCLUDED IN THE CONTRACT.
WAIVER OF RESPONSIBILITY OR REQUEST FOR ADDITIONAL PAYMENT BASED ON LACK OF KNOWLEDGE OF THE EXISTING CONDITION
AT THE SITE SHALL BE NOT ACCEPTED.
3- ALL OF THE CONSTRUCTION WORK INCLUDING MECHANICAL, ELECTRICAL AND PLUMBING SHALL BE PERFORMED BY REGISTERED AND LICENSED CONTRACTORS. EACH CONTRACTOR IS RESPONSIBLE FOR THEIR PART OF CONSTRUCTION WORK FOR
CONSTRUCTION MEANS, METHODS, PROCEDURES AND SAFETY OF THE CONSTRUCTION CREW.
4- THE CONTRACTORS SHALL FOLLOW APPLICABLE CODES AND REGULATIONS IN PERFORMING THE CONSTRUCTION WORK INCLUDING THE SAFETY REQUIREMENTS OF THE JOB SITE. NO WORK SHALL BEGIN PRIOR TO ISSUING OF THE BUILDING PERMIT.
NOTIFY THE ARCHITECT OF ANY CHANGES MADE ON THE PERMIT PLANS, INCLUDING SUBCONTRACTOR'S PERMITS, PRIOR TO
COMMENCEMENT OF THE CONSTRUCTION WORK.
5- ALL EQUIPMENT SHALL BE NEW (UNLESS NOTED OTHERWISE) AND SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE
MANUFACTURER'S RECOMMENDATION UNLESS NOTED OTHERWISE.
6- THE CONSTRUCTION WORK SHALL BE PERFORMED IN AN OCCUPIED BUILDING, THE CONTRACTOR SHALL AT ALL TIMES KEEP THE NOISE AND DUST DOWN IN ORDER NOT TO DISTURB THE OCCUPANTS. COORDINATE THE WORK WITH RESPECTIVE TENANT AND NOTIFY THEM OF ANY DISRUPTION IN BUILDING SERVICES PRIOR TO SUCH WORK. SCHEDULE THE CONSTRUCTION WORK IN ORDER TO MINIMIZE DISRUPTION TO THE TENANT OPERATION. THE CONTRACTOR SHALL OBTAIN THE TENANT'S APPROVAL OF THE
CONSTRUCTION SCHEDULE PRIOR TO THE BEGINNING OF THE CONSTRUCTION WORK.
7- THE CONTRACTORS SHALL BE RESPONSIBLE FOR ALL THE DIMENSIONS AND JOB CONDITIONS. NOTIFY THE ARCHITECT OF ANY DEVIATIONS AND/OR DISCREPANCIES BEFORE ANY CONSTRUCTION OR FABRICATION. CONTRACTORS SHALL NOT OBTAIN
DIMENSIONS BY SCALING THE PLANS.
8- THE CONTRACTORS SHALL COORDINATE ALL DETAILS WITH PLANS AND WHERE DETAILS NOT SHOWN ON THE DRAWINGS, IF NECESSARY, PREPARE SHOP DRAWINGS SHOWING COMPLETE DETAILS FOR CONSTRUCTION AND RELATION TO ADJACENT ELEMENTS. THE SHOP DRAWINGS SHALL BE FORWARDED TO THE ARCHITECT FOR REVIEW AND COMMENT.
9- ALL PAINTS, CARPET AND OTHER FINISHES SHALL BE IN ACCORDANCE WITH THE APPLICABLE CODES FOR FLAME SPREAD AND
SMOKE DEVELOPMENTS, ETC.
10- WHERE WALLS, FINISHES, ETC. ARE INDICATED TO BE REMOVED, REPAIR AND PREPARE THE REMAINING SURFACES FOR THE NEW FINISHES AND PROVIDE LABOR AND MATERIALS NEEDED FOR A COMPLETE REFINISHING JOB.
11- WHERE ITEMS ARE REQUIRED TO BE RELOCATED, PROVIDE MEANS NEEDED FOR RELOCATION AND COMPLETE REINSTALLATION.
12- IF AN ITEM SPECIFIED IS NOT AVAILABLE IN THE MARKET WITHIN THE TIME FRAME REQUIRED, SUBMIT A SUBSTITUTE TO THE ARCHITECT FOR APPROVAL. SUBSTITUTED ITEM(S) SHALL MEET OR EXCEED THE REQUIREMENTS OF THOSE SPECIFIED, UNLESS
NOTED THAT SUBSTITUTIONS ARE NOT ACCEPTABLE.
13- DISPOSE MATERIALS AND ITEMS REMOVED FROM BUILDING OFF SITE AT THE END OF EACH DAY.
14- THE CONTRACTORS IS RESPONSIBLE TO NOTIFY THE LOCAL BUILDING INSPECTION AUTHORITIES FOR INSPECTION, AS REQUIRED, DURING THE CONSTRUCTION. OBTAIN ALL FINAL INSPECTIONS AND APPROVALS PRIOR TO THE SUBSTANTIAL
COMPLETION OF THE WORK AND ALL THE APPROVAL NOTICES TO THE OWNER.
15- THE CONTRACTOR SHALL GUARANTEE THAT THE ENTIRE WORK OF THIS CONTRACT BE FREE OF DEFECTS FOR ONE YEAR FROM COMPLETION OF THIS CONTRACT. ANY DEFECT OCCURRING DURING THE GUARANTEE PERIOD SHALL BE CORRECTED AT NO COST TO THE OWNER AND PROMPTLY CORRECTED. FORWARD ALL MANUFACTURER'S WARRANTIES, WHERE APPLICABLE TO THE OWNER.
16- IN CASE OF DISCREPANCIES BETWEEN DIFFERENT PARTS OF PLANS, DETAILS BETWEEN DRAWINGS AND SPECIFICATIONS, THE MOST STRINGENT REQUIREMENTS SHALL APPLY, UNLESS OTHERWISE DETERMINED BY THE ARCHITECT. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES PROMPTLY. CONTRACTOR SHALL PROVIDE CREDIT, IF LESS STRINGENT REQUIREMENT SELECTED BY THE
ARCHITECT.
17- EXCLUSION OF THE REQUIREMENTS OF THESE DRAWINGS FROM THE CONSTRUCTION CONTRACT IS NOT ACCEPTABLE.
REASONABLE ASSUMPTION SHALL BE MADE FOR TIME REQUIRED TO OBTAIN LOCAL PERMITS AND TIME SHALL BE CONSIDERED IN THE CONSTRUCTION SCHEDULE. REQUEST FOR ADDITIONAL TIME FOR OBTAINING REQUIRED PERMITS WILL NOT BE ACCEPTABLE.
ALL REQUIRED PERMIT APPLICATIONS AND SUBMITTALS SHALL BE DONE IN A TIMELY FASHION AND IMMEDIATELY AFTER THE AWARD
OF THE CONSTRUCTION CONTRACT IN ORDER NOT TO DELAY THE APPROVAL PROCESS.
GENERAL NOTES
NVICINITY MAP AREA MAP
PROJECT VICINITY PROJECT SITE
G000 COVER SHEET
G001 ABBREVIATIONS & SYMBOLS
G002 SCOPE OF WORK NARRATIVE AND ADD ALTERNATES
G003 SCOPE OF WORK - MINIMUM BID QUANTITIES
AD100 LEVEL 1 DEMO FLOOR PLAN
AD200 OVERALL DEMO ROOF PLAN
AD308 DEMO-ENLARGED NORTH VESTIBULE ROOF PLAN & ELEV
AD309 DEMO-ENLARGED EAST VESTIBULE ROOF PLAN & ELEV
AD310 DEMO-ENLARGED SOUTH VESTIBULE ROOF PLAN & ELEV
AD502 ROOF - B1 EAST DEMO PLAN
AD503 OPC ROOF DEMO PLAN
A100 LEVEL 1 FLOOR PLAN
A200 OVERALL ROOF PLAN
A301 OVERALL NORTH AND EAST ELEVATIONS
A302 OVERALL SOUTH AND WEST ELEVATIONS
A303 ENLARGED EAST ELEVATION
A304 ENLARGED NORTH ELEVATION
A305 ENLARGED PARTIAL SOUTH ELEVATION
A306 ENLARGED WEST ELEVATION
A307 ENLARGED PARTIAL NORTH AND SOUTH ELEVATIONS
A308 NEW-ENLARGED NORTH VESTIBULE PLANS & ELEV.
A309 NEW-ENLARGED EAST VESTIBULE PLANS & ELEV.
A310 NEW-ENLARGED SOUTH VESTIBULE PLANS & ELEV.
A311 NEW - VESTIBULE DETAILS
A312 OPC PENTHOUSE ELEVATIONS
A313 ELEVATOR MACHINE ROOM ELEVATIONS
A314 ENLARGED PARTIAL BLDG 1 SOUTH ELEVATION
A315 EAST WING BUILDING PENTHOUSES
A400 ENLARGED CHAPEL ROOF BRIDGE
A401 ENLARGED CHAPEL ROOF BRIDGE - STAIR DETAILS
A402 CORRIDOR ICRA PLAN
A403 ICRA MATRIX FOR CORRIDOR WORK
A501 BUILDING 1 ROOF PLAN - EAST WING
A502 BUILDING 1 ROOF PLAN - WEST WING
A503 OPC ROOF PLAN
A801 TERRA COTTA/ CONCRETE REPAIR DETAIL
A802 TERRA COTTA/ CONCRETE REPAIR DETAILS CONT.
A803 TERRA COTTA/ CONCRETE REPAIR DETAILS
A804 TERRA COTTA/ CONCRETE REPAIR DETAIL CONT.
A806 STUCCO AND EIFS DETAILS
A807 CONCRETE/ WINDOW SILL REPAIR DETAILS
A808 METAL SUNSHADE DETAILS
A810 STOREFRONT DETAILS - ALT A
A811 STOREFRONT DETAILS - ALT B
A812 OPC WINDOWS - LEVEL 1
A813 OPC WINDOWS - UPPER LEVELS
A820 ROOF DETAILS
A821 ROOF DETAILS
A830 DOOR SCHEDULE
SG.1 STRUCTURAL NOTES AND INDEX SHEET
SG.2 STRUCTURAL SPECIAL INSPECTION NOTES
S2.3 PARTIAL FRAMING PLAN - LEVEL 3
S5.1 TYPICAL DETAILS
EG.1 ELECTRICAL COVER SHEET
EP2.1 ELECTRICAL DEMOLITION AND REMODEL PLAN - LEVEL 1
EP2.2 ELECTRICAL REMODEL PLAN - CHAPEL ROOF
H0.1 HVAC GENERAL NOTES & SHEET INDEX
H2.1 VESTIBULE PARTIAL FLOOR PLAN
N
PROJECT INFORMATION
APPLICABLE CODES
APPLICABLE STANDARDS
2021 IBC, 2021 INTERNATIONAL BUILDING CODE, PREPARED BY THE
INTERNATIONAL CODE COUNCIL, WASHINGTON, D.C.
CBC 2022, CALIFORNIA BUILDING CODE
ASCE 7-16, SUPPLEMENT 1 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES
ACI 318-19, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE
NATIONAL ELECTRICAL SAFETY CODE, ANSI C2
NFPA 10-2021, STANDARD FOR PORTABLE FIRE EXTINGUISHERS
NFPA 13-2021, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS
NFPA 14-2021, STANDARD FOR THE INSTALLATION OF STANDPIPE AND HOSE SYSTEMS
NFPA 20-2021, STANDARD ON CLEAN AGENT FIRE EXTINGUISHING SYSTEMS
NFPA 72-2021, NATIONAL FIRE ALARM AND SIGNALING CODE
NFPA 88A-2021, STANDARD FOR PARKING STRUCTURES
NFPA 101-2021, LIFE SAFETY CODE
ASCE 7-16, MINIMUM DESIGN LOADS AND ASSOCIATED CRITERIA FOR BUILDINGS AND OTHER STRUCTURES, AMERICAN SOCIETY OF CIVIL ENGINEERS, RESTON, VIRGINIA.
CISPI 310, SPECIFICATION FOR COUPLING FOR USE IN CONNECTION WITH HUBLESS CAST IRON SOIL PIPE AND FITTINGS FOR SANITARY AND STORM DRAIN, WASTE, AND VENT PIPING APPLICATIONS, 2012.
U.S. DEPARTMENT OF VETERANS AFFAIRS, PG-18-3 DESIGN AND CONSTRUCTION PROCEDURES, 2019
U.S. DEPARTMENT OF VETERANS AFFAIRS, H-18-8 SEISMIC DESIGN REQUIREMENTS, 2019
U.S. DEPARTMENT OF VETERANS AFFAIRS, PG-18-10 DESIGN MANUALS.
U.S. DEPARTMENT OF VETERANS AFFAIRS, VA PARKING DESIGN MANUAL, 2016.
U.S. DEPARTMENT OF VETERANS AFFAIRS, PHYSICAL SECURITY DESIGN MANUAL, 2015.
U.S. DEPARTMENT OF VETERANS AFFAIRS VA ARCHITECTURAL DESIGN MANUAL, 2014.
U.S. DEPARTMENT OF VETERANS AFFAIRS, VA HEALING ENVIRONMENTS DESIGN GUIDELINES, 2016.
U.S. DEPARTMENT OF VETERANS AFFAIRS, VA MENTAL HEALTH DESIGN GUIDE, 2017
U.S. DEPARTMENT OF VETERANS AFFAIRS, VA SIGNAGE AND WAYFINDING DESIGN MANUAL,
SECTIONS 04 AND 05, 2012.
ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS, 2015
NATIONAL ELECTRICAL MANUFACTURER’S ASSOCIATION (NEMA)
SHEET LIST
GENERAL
DEMOLITION
ARCHITECTURAL
STRUCTURAL
ELECTRICAL
MECHANICAL
Revisions: Date:
Ø DIAMETER
& AND
@ AT
# NUMBER, POUND
± APPROXIMATELY
(E) EXISTING
AB ANCHOR BOLT
ABR ABRASIVE
ABV ABOVE
AC AIR CONDITIONING
ACC ACCESS(IBLE)
ACIP ARCHITECTURAL CAST IN PLACE CONCRETE
ACOUS ACOUSTIC(AL)
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADH ADHESIVE
ADJ ADJACENT, ADJUSTABLE
AFF ABOVE FINISHED FLOOR
AGGR AGGREGATE
AIB AIR INFILTRATION BARRIER
AL ALUMINUM
ALTALTERNATE
AP ACCESS PANEL
APC ARCHITECTURAL PRECAST CONCRETE
APPROX APPROXIMATE
ARCH ARCHITECT(URAL)
AVB AIR & VAPOR BARRIER
BD BOARD
BG BUMPER GUARD
BIT BITUMINOUS
BKR BACKER
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BLW BELOW
BM BEAM, BENCHMARK
BOT BOTTOM
BR BEDROOM
BRCG BRACING
BRG BEARING
BRK BRICK
BRKT BRACKET
BS BOTH SIDES, BACKSPLASH
BSMT BASEMENT
BTWN BETWEEN
C/C CENTER TO CENTER
CAB CABINET
CB CATCH BASIN, CHALKBOARD, CONTROL BOX
CBP COMPOSITE BUILDING PANEL
CEM CEMENT
CFI CONTRACTOR FURNISHED AND INSTALLED
CFMF COLD FORMED METAL FRAMING
CG CORNER GUARD
CH CEILING HEIGHT
CI CAST IRON
CIP CAST IN PLACE CONCRETE
CJ CONTROL JOINT
CL CENTERLINE, CLOSET
CLG CEILING
CLR CLEAR
CMPTR COMPUTER
CMU CONCRETE MASONRY UNIT
COL COLUMN
COMM COMMUNICATION
COMP COMPRESSIBLE
CONC CONCRETE
CONF CONFERENCE
CONST CONSTRUCTION
CONST JT CONSTRUCTION JOINT
CONT CONTINUOUS
CONTR CONTRACTOR
CONV CONVECTOR
COORDCOORDINATE
CORR CORRIDOR, CORRUGATED
CP COMMON PATH (OF TRAVEL)
CPT CARPET
CR CRASH RAIL
CRS COURSE
CS CAST STONE
CSK COUNTERSUNK
CSWK CASEWORK
CT CERAMIC TILE
CTR CENTER
CTS COUNTERTOP SINK
CUB CUBICLE
CUH CABINET UNIT HEATER
D DEPTH
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIMDIMENSION
DISP DISPENSER
DMPF DAMPPROOFING
DN DOWN
DO DITTO
DR DOOR
DS DOWNSPOUT
DW DISHWASHER
DWG DRAWING
DWL DOWEL
DWR DRAWER
DWTR DUMBWAITER
EA EACH
EB EXPANSION BOLT
EF EACH FACE
EIFS EXTERIOR INSULATION & FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION (GRADE, FLOOR)
ELEC ELECTRIC(AL)
ELEV ELEVATION (BLDG), ELEVATOR
EMBMT EMBEDMENT
EMER EMERGENCY
ENCL ENCLOSURE
ENGR ENGINEER(ING)
ENTR ENTRANCE
EP ELECTRICAL PANELBOARD
EQ EQUAL
EQUIP EQUIPMENT
EW EACH WAY
EWC ELECTRIC WATER COOLER
EWS EYE WASH STATION
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
EXTR EXTRUDED
FA FIRE ALARM
FCU FAN COIL UNIT
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FLOOR
FGB FIBERGLASS FACED SILICONE TREATED
GYPSUM CORE SHEATHING BOARD
FGL FIBERGLASS
FH FLATHEAD
FIN FINISH
FL FLASHING
FLDG FOLDING
FLR FLOOR
FLUOR FLUORESCENT
FM FLOOR MAT
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOW FACE OF WALL
FP FROST PROOF
FPRF FIREPROOF(ED)(ING)
FR FRAME
FRT FIRE RETARDANT TREATED
FS FAR SIDE, FULL SIZE
FSFG FIRE SAFING
FSP FIRE STAND PIPE
FT FOOT, FEET
FTG FOOTING
FTR FINNED TUBE RADIATION
FURN FURNITURE
FURR FURRING
FUT FUTURE
FWC FABRIC WALL COVERING
FXTR FIXTURE
GA GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GFRG GLASS FIBER REINFORCED GYPSUM
GGBFS GROUND GRANULATED BLAST FURNACE SLAG
GL GLASS
GR GRADE
GRC GLASS FIBER REINFORCED CONCRETE
GRL GRILLE
GRTG GRATING
GSF GROSS SQUARE FEET
GSKT GASKET
GWB GYPSUM WALLBOARD
GYP GYPSUM
H HIGH
HC HANDICAPPED
HCT HANDICAPPED ACCESSIBLE TOILET
HD HEAD
HDBD HARDBOARD
HDW HARDWARE
HDWD HARDWOOD
HFS HALF FULL SIZE
HGT HEIGHT
HM HOLLOW METAL
HORIZ HORIZONTAL
HP HIGH POINT, HIGH PRESSURE,
HORSE POWER
HR HOUR, HANDRAIL
HVAC HEATING, VENTILATION, AIR CONDITIONING
ID INSIDE DIAMETER
IF INSIDE FACE
IN INCH
INCL INCLUDING
INS INSULATION
INT INTERIOR
INV INVERT
JAN JANITOR
JB JUNCTION BOX
JCTJUNCTION
JSTJOIST
JT JOINT
K KIP
KIT KITCHEN
KO KNOCK OUT
KPL KICK PLATE
L LONG
LAB LABORATORY
LAM LAMINATE(D)(ION)
LAT TIELATERAL TIEBACK FOR APC PANEL
LAV LAVATORY
LB POUND
LIN LINEAR
LKR LOCKER
LL LIVE LOAD, LEAD LINED
LLHLONG LEG HORIZONTAL
LLVLONG LEG VERTICAL
LP LIGHT PROOF, LOW PRESSURE, LOW POINT
LTG LIGHTING
LVR LOUVER
M METER
M MEN'S
MACH MACHINE
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MB MARKER BOARD
MBR MEMBER
MDF MEDIUM DENSITY FIBERBOARD
MECH MECHANICAL
MEMB MEMBRANE
MET METAL
MEZZ MEZZANINE
MFR MANUFACTURER
MH MANHOLE
MIFRC MASTIC INTUMESCENT FIRE RESISTIVE COATING
MINMINIMUM
MIRMIRROR
MISC MISCELLANEOUS
MJ MOVEMENT JOINT (IN MASONRY)
MLDG MOLDING
MLWK MILLWORK
MM MILLIMETER
MO MASONRY OPENING
MSCQ METAL STUD CURTAIN WALL
MTD MOUNTED
MTG MOUNTING
MULL MULLION
MWMINERAL WOOL
MWF MEMBRANE WALL FLASHING
N NORTH
NA NOT APPLICABLE
NF NEAR FACE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NRC NOISE REDUCTION COEFFICIENT
NS NEAR SIDE
NSF NET SQUARE FEET
NTS NOT TO SCALE
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OFF OFFICE
OFOI OWNER FURNISHED OWNER INSTALLED
OH OPPOSITE HAND, OVERHEAD
OPNG OPENING
OPP OPPOSITE
PAR PARALLEL
PASS PASSAGE, PASSENGER
PB PUSH BUTTON
PBD PARTICLE BOARD
PC PRECAST (STRUCTURAL)
PED PEDESTAL
PER PERIMETER
PERP PERPENDICULAR
PF PREFABRICATED PANEL
PGBD PEGBOARD
PL PLATE, PROPERTY LINE
PLAM PLASTIC LAMINATE
PLAS PLASTIC
PLAT PLATFORM
PLBG PLUMBING
PLK PLANK
PLWD PLYWOOD
PNEU PNEUMATIC
PNL PANEL
PNT PAINT
PR PAIR
PREFAB PREFABRICATED
PRELIMPRELIMINARY
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POINT, PRESSURE TREATED
(FOR MOISTURE)
PTD PAINTED
PTN PARTITION
QT QUARRY TILE
R RISER
RAD RADIUS
RAF RAISED ACCESS FLOOR
RBR RUBBER
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REC RECESSED
RECPT RECEPTACLE
RECT RECTANGULAR
REF REFERENCE
REFR REFRIGERATION
REG REGISTER
REINF REINFORCE(D)(ING)(MENT)
REQD REQUIRED
RES RESILIENT
RET RETAINING, RETURN
REV REVISION
RFG ROOFING
RJ RUSTICATION JOINT
RLG RAILING
RM ROOM
RO ROUGH OPENING
RS RESILIENT SHEET
RT RESILIENT TILE
RWC RAIN WATER CONDUCTOR
SAFB SOUND ATTENUATION FIRE BLANKET
SAN SANITARY
SB SPLASH BLOCK
SCHED SCHEDULE
SECT SECTION
SECY SECRETARY
SF SQUARE FEET
SFRM SPRAYED FIRE-RESISTANT MATERIAL
SGL SINGLE
SH SHELF
SHR SHOWER
SHT SHEET(ING)
SHTNG SHEATHING
SIMSIMILAR
SK SINK
SL SEALANT
SMLS SEAMLESS
SP SPACE(ING)
SPEC SPECIFICATION
SPF SPRAY FOAM
SPFI SPRAY POLYURETHANE FOAM INSULATION
SPKR SPEAKER
SPR SPRINKLER
SPD STERILE PROCESSING DEPARTMENT
SQ SQUARE
SR SERVICE RECEPTOR
SS SERVICE SINK
SST STAINLESS STEEL
SSUR SOLID SURFACING
STA STATION
STAGG STAGGERED
STC SOUND TRANSMISSION CLASS
STD STANDARD
STIFF STIFFENER
STLSTEEL
STOR STORAGE
STR STRUCTURAL
SUPP SUPPORT
SURF SURFACE
SUSP SUSPENDED
SYM SYMBOL, SYMMETRICAL
SYS SYSTEM
T TREAD, FLUSH MOUNTED TELEPHONE
T&G TONGUE AND GROOVE
TA TOILET ACCESSORIES
TB TACKBOARD, TOWEL BAR
TD TRAVEL DISTANCE
TELTELEPHONE
TEMP TEMPORARY, TEMPERED
TERR TERRAZZO
THK THICK(NESS)
TOB TOP OF BEAM
TOC TOP OF CURB, CONCRETE
TOP TOP OF PEDESTAL
TOS TOP OF STEEL
TOSL TOP OF SLAB
TOW TOP OF WALL
TR TOILET ROOM
TRANS TRANSITION
TS TUBE STEEL
TV TELEVISION
TYP TYPICAL
UC UNDERCOUNTER
UH UNIT HEATER
UNEX UNEXCAVATED
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
UR URINAL
UTIL UTILITY
VAR VARIES
VB VAPOR BARRIER
VCT VINYL COMPOSITION TILE
VEN VENEER
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VIN VINYL
VOL VOLUME
VP VENEER PLASTER
VT VINYL TILE
VTR VENT THRU ROOF
VWC VINYL WALL COVERING
W WIDE, WOMEN'S
W/ WITH
W/O WITHOUT
WC WATER CLOSET, WHEELCHAIR
WD WOOD
WF WIDE FLANGE
WIN WINDOW
WMWALK OFF MAT
WP WORKING POINT, WATERPROOF(ING),
WALL PROTECTION
WR WATER RESISTANT, WASTE RECEPTOR
WS WATER STOP
WSCT WAINSCOT
WT WEIGHT, WINDOW TREATMENT
GENERAL ABBREVIATIONS
BRICK
CONCRETE
CONCRETE MASONRY UNIT
CRUSHED STONE
EARTH
INSULATION (BATT)
INSULATION (RIGID)
METAL (ALUMINUM)
METAL (STEEL, IRON)
PLYWOOD
WOOD FINISH
WOOD FRAMING & BLOCKING
GYPSUM WALL BOARD
COLUMN REFERENCE GRID
A
UP
DN
SLOPE UP
SLOPE DOWN
TRUE NORTH
BUILDING NORTH
KEYPLAN COMBINATION NORTH ARROW
KEYPLAN COMBINATION NORTH ARROW
N
FLOOR ELEVATION
EL 20'-0"
SYMBOL LEGEND
3.
EXIST WALLS, DOORS (SCREENED)
DEMOLITION WALLS, DOORS (DASHED)
NEW WALLS, DOORS (SOLID)
DOOR TAG
6" UNLESS NOTED OTHERWISE
ROOM
NAME
ROOM NAME AND NUMBER
PARTITION TYPE, SEE A4.1
G3A
ELEVATION REFERENCES (ARROW INDICATES DIRECTION OF VIEW)
A5.1.1
A3.3.2
INTERIOR ELEVATION NUMBER
MULTIPLE ELEVATION NUMBER A5.1.1
DETAIL NUMBER
SHEET NUMBER A3.3.2
TYP
NOTE
SECTION/DETAIL REFERENCES (ARROW INDICATES DIRECTION OF VIEW)
(DETAIL ELEVATION ON SAME SHEET)
(SHEET NUMBER NOT REQUIRED IF
DETAIL ELEVATION IS ON SAME SHEET)
A3.3.1.5
BUILDING SECTION NUMBER
SHEET NUMBER A3.3.15
TYP
NOTE
DETAIL PLAN/ELEVATION (BOX INDICATES AREA OF VIEW)
A2.1
DETAIL NUMBER
SHEET NUMBER
DIMENSION TO FACE
DIMENSION TO CENTERLINE
(TYP DIM. TO CENTERLINE OF PTN)
DIMENSION CONTINUES
LIMIT OF WORK
AREA OF REVISION
REVISION
DEMOLITION AND/OR ALTERATION NOTE
L2
W2
AP
EP
FEC
WORK POINT, CONTROL
POINT, OR DATUM POINT
CASEWORK UTILITY (INDIVIDUAL)
CASEWORK UTILITY (GROUP)
LOUVER TYPE
WINDOW TYPE
ACCESS PANEL
ELECTRIC PANEL
FIRE EXTINGUISHER CABINET
PB
A
CR
CARD READER
ACTUATOR (POWER OPERATOR)
PUSH BUTTON (RELEASE)
SENSORS (DOOR CONTROL)
A3.2 1 EXTERIOR ELEVATION NUMBER A3.2
(SHEET NUMBER NOT REQUIRED IF
DETAIL ELEVATION IS ON SAME SHEET)
A3.3.1.5
WALL SECTION NUMBER
SHEET NUMBER A3.3.15
TYP
NOTE
A3.3.1.5
PLAN/SECTION DETAIL NUMBER
SHEET NUMBER A3.3.15
TYP
NOTE
2 G3A
PROJECT AREA LINE
PROPERTY LINE
THIS LINE GENERALLY INDICATES
THE AREA WHERE THE WORK OF
THIS PROJECT OCCURS;
SOME INCIDENTAL WORK MAY
OCCUR OUTSIDE THIS LINE.
Architecture Engineering Design-Build paradigm
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% NOT FOR CONSTRUCTION
BID DOCUMENTS
Office of Construction &
Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT / ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
570-21-108VA CENTRAL CALIFORNIA HEALTH CARE SYSTEM
REPAIR EXTERIOR FINISHES BLDG 1 & OPC
2615 EAST CLINTON AVENUE
FRESNO, CA 93703-2223
1-23-2026
Project Director
9000 Wessex Place, Suite 202, Louisville, KY 40222 www.paradigmusa.com
FULLY SPRINKLERED
AR TL
1-23-2026
Au to de sk
D oc s:
//F
R E2
- F re sn o
R ep ai r E xt er io r F in is he s, B ui ld in g
O ut pa tie nt
/F R
E2
1- A
- V A
Fr es no E xt er io r.r vt 1/
/2
4:
:5
PM
G001
ABBREVIATIONS & SYMBOLS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% NOT FOR CONSTRUCTION
BID DOCUMENTS
Office of Construction &
Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT / ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
570-21-108VA CENTRAL CALIFORNIA HEALTH CARE SYSTEM
REPAIR EXTERIOR FINISHES BLDG 1 & OPC
2615 EAST CLINTON AVENUE
FRESNO, CA 93703-2223
1-23-2026
Project Director
9000 Wessex Place, Suite 202, Louisville, KY 40222 www.paradigmusa.com
FULLY SPRINKLERED
AR TL
1-23-2026
Au to de sk
D oc s:
//F
R E2
- F re sn o
R ep ai r E xt er io r F in is he s, B ui ld in g
O ut pa tie nt
/F R
E2
1- A
- V A
Fr es no E xt er io r.r vt 1/
/2
4:
:5
PM
G002
SCOPE OF WORK NARRATIVE AND
ADD ALTERNATES
1.0 - SCOPE 1 - BUILDING 1 AND OPC ENVELOPE REPAIRS: (SEE A800 SERIES)
REPAIRS ARE IDENTIFIED IN THE FOLLOWING DOCUMENTS:
FACADE INSPECTION REPORT, “VAMC FRESNO FACADE INSPECTION DRAFT REPORT, DATED JUNE 5, 2009, BY
TOLAND-MIZELL ARCHITECTS, INC. AND APPLIED ENGINEERING SOLUTIONS, INC.
FACADE STUDIES VISN 9, 15,19,20,21, 21, 22, FRESNO VA MEDICAL CENTER, BUILDING 1, FINAL REPORT, DATED 23
SEPTEMBER 2022
FACADE CONDITION ASSESSMENT, VETERAN AFFAIRS MEDICAL CENTER, 2615 EAST CLINTON AVENUE, FRESNO, CA, TERRACON PROPOSAL NO. PFT226094, BY TERRACON, DATED OCTOBER 13, 2023
SCOPE 1.1 - GENERAL:
BEFORE COMMENCEMENT OF REPAIRS, THE BUILDING ENCLOSURE SHOULD BE THOROUGHLY CLEANED USING NON-ABRASIVE METHODS. CONDUCT TESTS IN NON-CONSPICUOUS AREAS TO CONFIRM THE MOST EFFECTIVE METHOD OF CLEANING PRIOR TO COMMENCING CLEANING OF THE ENTIRE FACADE. CONSULT WITH THE INTERNATIONAL MASONRY INSTITUTE ON CLEANING PRODUCTS AND METHODS. DURING CLEANING OF THE FACADE, CONDUCT A DETAILED EXAMINATION RECORDING AND VERIFYING
THE FULL EXTENT OF REPAIRS REQUIRED FOR THE OBSERVED DEFICIENCIES NOTED BELOW.
AREAS OF REPAIR WORK NOTED IN THESE DOCUMENTS FORM THE BASE BID FOR SCOPE 1.
DOCUMENT AREAS OF REPAIR NOT IDENTIFIED IN BID DOCUMENTS AND TYPE OF REPAIR REQUIRED PRIOR TO COMMENCING REPAIR WORK. PROVIDE SHOP DRAWINGS TO DOCUMENT AREAS OF ADDITIONAL DAMAGE DISCOVERED DURING CLEANING.
PROVIDE UNIT COST FOR ADDITIONAL REPAIRS NOT IDENTIFIED IN THESE DOCUMENTS
THE GOVERNMENT HAS THE OPTION TO AUTHORIZE ADDITIONAL WORK BASED CONDITIONS FOUND DURING THE CLEANING
AND INSPECTION PROCESS BASED ON THE UNIT COSTS PROVIDED IN THE CONTRACTORS BID.
THE GOVERNMENT IS NOT OBLIGATED OR COMMITTED FOR ADDITIONAL WORK DISCOVERED AND DOCUMENTED DURING THE
CLEANING AND INSPECTION PHASE OF THE WORK.
1.2 - TERRA COTTA CLADDING: (SEE DETAIL SHEETS A801-A802)
1.2.1 - UNSOUND AND SIGNIFICANTLY CRACKED TERRA COTTA UNITS: UNITS THAT HAVE CRACKED OR EXHIBIT CONSIDERABLE SPALLING AND HAVE BECOME DISLODGED FROM THEIR ANCHORS AND/OR SEPARATED FROM THE SETTING BED BENEATH.
REPAIRS:
REMOVE AND REPLACE UNITS THAT HAVE MULTIPLE CRACKS AND OR LARGE SPALLED SURFACES. MATERIAL OPTIONS FOR REPLACEMENT UNITS INCLUDE TERRA COTTA OR GLASS FIBER REINFORCED CONCRETE (GFRC). FOR REPLACING TERRA
COTTA UNITS, FOLLOW THE INTERNATIONAL MASONRY INSTITUTE’S (IMI) GUIDELINES.
UNITS THAT ARE SUBSTANTIALLY INTACT CAN BE REMOVED AND RESET WITH NEW STAINLESS-STEEL ANCHORS. FOR
RESETTING TERRA COTTA UNITS FOLLOW IMI’S GUIDELINES.
1.2.2 – SOUND CRACKED TERRA COTTA UNITS: REPAIR BY STABILIZING-IN-PLACE UNITS THAT EXHIBIT A SINGLE CRACK BUT ARE OTHERWISE SOUND USING ADDITIONAL PINNING AND/OR ANCHORS WITHOUT REMOVING THE UNIT. CRACKS ARE TO BE SEALED EITHER WITH A COATING OR SEALANT. FOR ANCHORING AND PINNING TERRA COTTA UNITS FOLLOW IMI ’S GUIDELINES
1.2.3.A - TERRA COTTA SILL SPALL, 1.2.3B TERRA COTTA PANELS SPALLS & 1.2.3C TERRA COTTA COPING STONE SPALL: REPAIRS:
UNITS AND PANELS THAT ARE SOUND, BUT EXHIBIT LARGE, SPALLED AREAS IN THE FACE OF THE PANELS, REPAIR BY REMOVING AND REPLACING UNITS. MATERIAL OPTIONS FOR REPLACEMENT UNITS INCLUDE TERRA COTTA OR GLASS FIBER REINFORCED CONCRETE (GFRC). FOR REPLACING TERRA COTTA UNITS FOLLOW THE IMI ’S GUIDELINES.
UNITS AND PANELS THAT EXHIBIT SMALL TO MODERATELY SPALLED SURFACES IN THE FACE OF THE PANELS, REPAIR BY USING MORTAR FOR UNGLAZED UNITS; AND FOR GLAZED UNITS TREAT WITH A PROTECTIVE COATING, FOLLOWING THE
RECOMMENDATIONS OF THE IMI.
1.2.4 – LOOSE, DETERIORATED AND MISSING MORTAR JOINTS IN TERRA COTTA CLADDING – REPAIRS MORTAR JOINTS BY CLEANING OUT AND CUTTING BACK TO A SUFFICIENT DEPTH FOR TUCK-POINTING. REPAIR PREPARATION AND MORTAR SHOULD FOLLOW THE RECOMMENDATIONS OF IMI. USE MORTAR MIX OF COMPATIBLE WITH TERRA MATERIALS AND EXISTING MORTAR.
1.2.5 - UNSEALED CUTS REPAIR: USE MORTAR TO REPAIR UNSEALED CUTS WHERE CUT DOES NOT ABUT ANOTHER MATERIAL SUCH AS METAL. USE A SEALANT TO SEAL BETWEEN TERRA COTTA UNITS AND OTHER MATERIALS. REPAIR PREPARATION AND
MORTAR/SEALANT TYPE SHOULD FOLLOW THE RECOMMENDATIONS OF IMI.
1.2.6 - EFFLORESCENCE AND STAINING IN TERRA COTTA UNITS: BEFORE COMMENCING REPAIR EXAMINE THE ROOT CAUSE OF EFFLORESCENCE AND STAINING TO DETERMINE IF MOISTURE IS DIGRESSING INTO THE CLADDING SYSTEM OR FROM WATER DRIPPING ONTO THE TERRA COTTA SURFACE. ONCE DETERMINED, IMPLEMENT REPAIRS TO WATER INFILTRATION OR SOURCE OF WATER DRIP. REMOVE EFFLORESCENCE AND STAINING FROM THE SURFACE OF THE TERRA COTTA UNITS USING THE LEAST ABRASIVE METHOD TO MAINTAIN THE FINISH OF THE UNITS. REPLACE UNITS IF STAIN CANNOT BE REMOVED. CLEANING
PREPARATION METHODS SHALL FOLLOW THE RECOMMENDATIONS OF IMI.
1.2.7 - DETERIORATED OR MISSING SEALANT JOINTS IN TERRA COTTA CLADDING: REPAIR BY REMOVING ALL SEALANTS THAT HAVE LOST ADHESION AND ARE DISPLACED. CLEAN BACK JOINT TO A SUFFICIENT DEPTH TO ALLOW FULL ADHESION OF SEALANT TO SUBSTRATES. USE SUITABLE BACKER MATERIALS TO ALLOW FOR JOINT SEALANT MOVEMENT. USE MANUFACTURER’S PRIMER IF RECOMMENDED. REPAIR PREPARATION AND SEALANT TYPE SHALL FOLLOW THE RECOMMENDATIONS OF IMI.
1.2.8 – EXTERIOR COATING DETERIORATION: REPAIR BY RECOATING TERRA COTTA UNITS AND PANELS BY APPLYING A CLEAR
ELECTROMETRIC COATING AFTER CLEANING.
1.3 - STUCCO CLADDING: (SEE DETAIL SHEET A806)
1.3.1 - SPALLS IN STUCCO CLADDING REPAIR: REMOVE SPALLS FROM SURFACE AND PATCH IN ACCORDANCE WITH RECOMMENDATIONS FROM THE PORTLAND CEMENT ASSOCIATION (PCA). PREPARE PATCH AND SURROUNDING SURFACE FOR
TEXTURED ELASTOMERIC COATING.
1.3.2 - CRACKS IN STUCCO CLADDING REPAIR: CRACKS LARGER THAT A HAIRLINE SHOULD BE ROUTED OUT AND REPAIRED USING A FILLER IN ACCORDANCE WITH RECOMMENDATIONS FROM PCA. SMALL CRACKS CAN BE SEALED USING A BRUSH GRADE SEALANT.
FOR SEALANTS FOLLOW MANUFACTURER ’S RECOMMENDATIONS FOR PREPARATION, PRIMERS AND APPLICATION METHODS.
1.3.3 - FAILED FINISHES IN STUCCO CLADDING: REPAIR FINISHES AFTER CORRECTION OF SOURCES OF MOISTURE INGRESS INTO THE WALL ASSEMBLY. TERMINATE STUCCO CLADDING A MINIMUM OF 4 INCHES, BUT NOT GREATER THAT 6 INCHES BY GRADE.
FOLLOW RECOMMENDATION OF THE PCA FOR REPAIRS
1.3.4 – STAINS IN STUCCO CLADDING: CLEAN STUCCO CLADDING AND RECOAT WITH FINISHED SURFACE WITH A COLORED
ELASTOMERIC COATING.
1.4 - EXPOSED CONCRETE: (SEE DETAIL SHEETS A807)
1.4.1 - CONCRETE SPALLS: REMOVE SPALLS FROM CONCRETE AND CUT BACK CONCRETE UNTIL ALL SURFACES ARE SOUND.
REPAIRS TO CONCRETE:
IF REINFORCEMENT IS EXPOSED DURING REMOVAL, THOROUGHLY REMOVE RUST DOWN TO CLEAN METAL. IF REINFORCEMENT HAS DETERIORATED BEYOND ITS STRUCTURAL CAPACITY, CUT-OUT DETERIORATED REINFORCEMENT, CUT-BACK CONCRETE AROUND SOUND REINFORCEMENT TO FORM AN OVERLAP, AS DETERMINED BY STRUCTURAL ENGINEER, COAT ALL REINFORCEMENT WITH EPOXY COATING, PRIME CONCRETE SURFACES, AND REINSTATE CONCRETE USING A CONCRETE MIX THAT MATCHES OR IS COMPATIBLE WITH THE EXISTING CONCRETE MIX. FOLLOW RECOMMENDATIONS OF THE AMERICAN CONCRETE INSTITUTE FOR REPAIRS AND DETAILS DEVELOPED BY THE STRUCTURAL
ENGINEERS. RECOAT NEW CONCRETE REPAIR TO MATCH EXISTING FINISHES.
SPALLS NOT EXPOSING REINFORCEMENT, ARE TO BE REPAIRED BY PRIMING CONCRETE SURFACES AND REINSTATING
CONCRETE REPAIR WITH PLASTER COATING AND PAINT WITH ELASTOMERIC COATING
1.4.2 - CONCRETE CRACKS: ROUTE OUT CRACKS LARGER THAN HAIRLINE IN CONCRETE TO ALLOW INSTALLATION OF SEALANT.
REMOVE ANY LOOSE MATERIALS. INSTALL SEALANT. FOLLOW SEALANT MANUFACTURER’S RECOMMENDATIONS FOR PRIMERS, AND SEALANT TYPE.
1.4.3 - DETERIORATED OR MISSING SEALANT: REMOVE FAILED SEALANT FROM JOINTS. CLEAN OUT JOINTS IN CONCRETE, REMOVING ANY LOOSE MATERIAL TO ALLOW INSTALLATION OF NEW SEALANT. INSTALL SEALANT. FOLLOW SEALANT
MANUFACTURER FOR PRIMERS AND SEALANT TYPE.
1.4.4 - FAILED CONCRETE COATING: REMOVE AREAS OF FAILED COATINGS DOWN TO BARE CONCRETE. ABRADE SURFACES TO BE
RECOATED AND APPLY NEW COATING TO MATCH EXISTING COATING FINISH.
2. 0 - SCOPE 2 - BUILDING 1, OPC, OPC2 GLAZING: (SEE A810 SERIES)
2.1.1 REPLACE SINGLE-GLAZED WINDOWS AND STOREFRONT WITH DOUBLE GLAZING:
DEMOLITION: THIS SCOPE OF DEMOLITION WORK INCLUDES THE FOLLOWING: REMOVAL OF THE GLAZING UNITS, FRAMING STOPS IN THE STOREFRONT, AND WINDOW FRAMING. CLEAN AWAY ANY SEALANT AND GASKET MATERIAL FROM THE ALUMINUM FRAMES. REMOVE INTERIOR BLINDS. DISPOSE ALL MATERIALS IN ACCORDANCE WITH FEDERAL
REGULATIONS AND LOCAL AND STATE REGULATORY REQUIREMENTS.
TEMPORARY PROTECTION AND MEASURES: PROVIDE FOR PHASED CONSTRUCTION AND OUT OF HOURS WORK TO LIMIT DISRUPTION FOR THE MEDICAL CENTER’S OPERATIONS. PROVIDE TEMPORARY PROTECTION TO MAINTAIN INTERIOR ENVIRONMENT AND INFECTION CONTROL (ICRA) AS WELL AS INSECT CONTROL, DURING CONSTRUCTION.
NEW WORK: REPLACE OR MODIFY EXISTING STOREFRONT AND WINDOW FRAMING TO ALLOW THE FRAMING TO RECEIVE THE NEW INSULATED GLAZING UNITS. REINFORCE ANCHORAGE IF REQUIRED TO ACCOMMODATE THE ADDITIONAL WEIGHT OF THE NEW GLAZING UNITS. FINISH OF THE ALUMINUM FRAMING SHALL MATCH THE EXISTING
FRAMING.
FOR THE ARCADE STOREFRONT FENESTRATION OF BUILDING 1, NEW OR REFURBISHED FRAMING MEMBERS
SHALL RECEIVE A POWDERED-COATED FINISH OR CLEAR ANODIZED FINISH.
FOR THE OPC WINDOW FRAMES, A BRONZE ANODIZED FINISH OR POWDERED COATED FINISH SHALL BE USED.
GLAZING UNITS FOR THE BUILDING 1 WILL BE CLEAR HIGH-PERFORMANCE INSULATED UNITS. THE NEW OPC INSULATED WINDOW GLAZING UNITS SHALL BE FABRICATED WITH A BRONZE TINTED OUTER LITE AND A CLEAR INNER LITE TO MATCH THE EXISTING GLAZING ON THE UPPER FLOORS OF THE OPC. PROVIDE BLAST FILM TO ALL
NEW UNITS.
IN BUILDING 1, THE LOWER GLAZING UNIT OF THE ARCADE STOREFRONT, THE BLAST FILM WILL HAVE A WHITE
TRANSLUCENT TINT.
PROVIDE FOR EITHER HORIZONTAL OR VERTICAL BLINDS AT ALL GLAZING OPENINGS TO MATCH EXISTING BLINDS.
2.1.2 - REPLACE EXISTING DOUBLE GLAZED WINDOWS: REPLACE WINDOWS WITH INTEGRAL BLINDS WITH NEW
INSULATED GLAZING UNITS AND BLINDS TO MATCH EXISTING
3.0 - SCOPE 3 - ROOF REPAIR OF LOWER ROOF OF OPC & WEST WING BUILDING 1: (SEE A820 SERIES)
SCOPE OF WORK: INCLUDES CLEANING OF ROOF WHERE LEAKS ARE OCCURRING, AND THE REMOVAL OF DEBRIS AND ABANDONED EQUIPMENT. CLEAN ROOF, REMOVING ANY ORGANIC MATERIALS FROM ROOF SURFACE. EXAMINE THE DECK FROM FLOOR BELOW TO DETERMINE THE EXTENT OF LEAKAGE THAT IS OCCURRING AND OBSERVING WHERE THE LEAKAGE EMANATES FROM. REMOVE ROOFING MEMBRANE DOWN TO INSULATION AND FLASHINGS IN THE AREA OF THE ROOF FAILURE. REMOVE COVER BOARD AND INSULATION THAT HAS INCURRED MOISTURE DAMAGE. REMOVE ANY ROOFING MATERIALS THAT EXHIBIT MOLD GROWTH. REPLACE ROOF INSULATION, MAINTAINING PROPER SLOPES TO DRAINS, COVER BOARDS, AND CUT-IN NEW ROOFING MEMBRANE PER MANUFACTURER ’S REPAIR DETAILS FOR EXISTING MEMBRANE. RESET ROOF DRAINS IN THE AREA OF THE LEAKAGE, WITH MEMBRANE CLAMPED INTO DRAIN.
SECURE DRAIN DOME OR REPLACE DOME IF MISSING. REPLACE FLASHING USING ROOFING MANUFACTURER’S APPROVED MATERIALS. RESEAL AROUND FLASHINGS, ROOFTOP EQUIPMENT, ETC. TO ENSURE AREAS VULNERABLE TO WATER INFILTRATION HAVE BEEN REPAIRED. FLOOD TEST FINISHED WORK TO PROVE EFFICACY OF REPAIR.
TEMPORARY PROTECTION AND MEASURES: REMOVAL SHALL BE DONE IN SECTIONS, COORDINATED WITH INSTALLATION OF NEW REPLACEMENT ROOF SO THAT ONLY A LIMITED PORTION OF THE ROOF IS EXPOSED AT ANY ONE TIME. PROVIDE APPROPRIATE LEVEL OF INFECTION CONTROL (ICRA) DURING CONSTRUCTION.
4.0 - SCOPE 4 - STAIR ACCESS FROM OPC TO BUILDING 1 CHAPEL ROOF: (SEE A400 SERIES & S2.3)
DEMOLITION: THIS SCOPE OF DEMOLITION WORK INCLUDES CUTTING THROUGH THE EXTERIOR WALL OF THE SECOND FLOOR CORRIDOR C-503-14 OF THE LINK BETWEEN OPC AND BUILDING 1, ALONG GRIDLINE B1 BETWEEN GRIDLINES 7 AND 8, FOR AN ACCESS DOOR OPENING AND FOR PLATFORM FRAMING AT COLUMNS B1/7 AND B1/8.
NEW WORK: NEW WORK INCLUDES INSTALLATION OF NEW INSULATED HOLLOW METAL DOOR AND FRAME INTO CORRIDOR C-502-13 EXTERIOR WALL AND WELDING OF HSS GALVANIZED STEEL PLATFORM FRAMING MEMBERS TO BUILDING FRAME AT COLUMNS B1/7 AND B1/8. REPAIR/PATCH EXTERIOR FINISHES AROUND STEEL FRAMING MEMBERS AND DOOR OPENING TO MATCH EXISTING. INSTALL PLATFORM FRAMING FOR ACCESS STAIR OVER THE PARAPET OF THE CHAPEL ROOF. ALL FRAMING WILL BE WELDED HSS OR WIDE-FLANGE MEMBERS, GALVANIZED. THE PLATFORM FLOOR, STAIR TREADS AND STAIR LANDING WILL BE MADE FROM NON-SLIP REINFORCED FIBERGLASS GRATING. STAIR STRINGERS, TOE KICKS WILL BE GALVANIZED PLATE STEEL AND HANDRAIL WILL BE GALVANIZED STEEL PIPE. ACCESS DOOR AND FRAME WILL BE PAINTED TO MATCH EXISTING STUCCO FINISHES.
TEMPORARY PROTECTION AND MEASURES: PROVIDE INFECTION CONTROL BARRIERS (ICRA) AND INSECT CONTROL DEVICES DURING CONSTRUCTION OF ACCESS DOOR IN THE EXTERIOR WALL AND THE EXTERIOR PLATFORMS AND
STAIRS.
5.0 - SCOPE 5 - REPAIR STOREFRONT NORTH, SOUTH & EAST DEMOLITION VESTIBULE BUILDING 1: (SEE AD300, A300 & A810 SERIES).
THE GENERAL CONCTRACTOR SHALL COORDINATE WITH THE VA COR FOR PHASING OF EACH VESTIBULE CONSTRUCTION TO
MAINTAIN AT LEAST TWO OPERATIONAL VESTIBULES FOR THE BUILDING EGRESS.
5.1 - NORTH VESTIBULE: DEMOLITION: FOR THIS SCOPE OF WORK DEMOLITION INCLUDES THE FOLLOWING: REMOVE ATTACHED AIR CURTAIN, SECURITY DEVICES; DOOR DEVICES FROM THE EXISTING EXTERIOR ENCLOSURE, REMOVE EXISTING OUTER SLIDING DOOR;
PARTIALLY DEMOLISH THE EXISTING CEILING AROUND EXTERIOR PERIMETER TO ALLOW FOR THE INSTALLATION OF NEW EXTERIOR ENCLOSURE; REMOVE EXTERIOR GLAZING UNITS. REMOVE PORTIONS OF THE CANOPY METAL ROOF DOWN TO STRUCTURAL MEMBERS. SALVAGE AIR CURTAINS AND SECURITY DEVICES FOR REUSE. DISPOSE OF ALL MATERIALS IN ACCORDANCE WITH
FEDERAL REGULATIONS AND LOCAL AND STATE REGULATORY REQUIREMENAARON.RUMPLETS.
TEMPORARY PROTECTION AND MEASURES: PROVIDE FOR PHASED CONSTRUCTION OF ENTRANCE VESTIBULE TO ALWAYS MAINTAIN SAFE EGRESS PATHS FROM THE BUILDING. PROVIDE TEMPORARY ENCLOSURES FOR THE EGRESS PATHS, INFECTION CONTROL (ICRA), INSECT CONTROLS, LIGHTING, AND SIGNAGE DURING CONSTRUCTION. MAINTAIN ALL FIRE PROTECTION AND FIRE ALARM
DEVICES.
NEW WORK: REPLACE OR MODIFY EXISTING FRAMING BY INSTALLING PARTIAL MULLIONS, GLAZING STOPS OR REPLACEMENT OF EXISTING ALUMINUM FRAMES TO RECEIVE NEW INSULATED GLAZING UNITS. NEW ALUMINUM FRAMING SHALL HAVE A CLEAR ANODIZED FINISH. FOR VISION AREAS OF GLAZING, PROVIDE CLEAR HIGH-PERFORMANCE INSULATED GLAZING UNITS. PROVIDE OPACIFIED FRITTED GLASS SPANDREL UNITS AT NON-VISION AREAS. INSTALL INSULATION BEHIND SPANDREL GLASS. REBUILD/REPAIR PERIMETER GYPSUM WALLBOARD SOFFIT AND INSTALL NEW ACOUSTICAL CEILING IN VESTIBULE CEILING. PROVIDE NEW AUTOMATIC INSULATED-GLASS SLIDING DOORS, WITH MOTION DETECTION SENSOR. REINSTALL SECURITY DEVICES AND AIR CURTAIN.
5.2 - EAST VESTIBULE: FOLLOW SCOPE OF WORK OUTLINED ABOVE FOR NORTH VESTIBULE, EXCEPT TO REPLACE EXISTING BI-
FOLDING DOORS WITH NEW INSULATED GLAZING AUTOMATIC GLASS.
5.2.1 - REPAIR FLASHING BETWEEN CANOPY AND VESTIBULE ROOF: REMOVE EXISTING FLASHING, SALVAGING EXISTING SECTIONS TO RESET. REPLACE ANY SECTION CURRENTLY DAMAGED OR DAMAGED DURING REMOVAL WITH NEW METAL SECTIONS. RESET FLASHING (EXPANSION JOINT COVER), ENSURING PROPER SEALED OVERLAP OF SECTIONS AND SEAL FLASHING TO SUBSTRATES WITH
PROPER EMBEDMENT IN COMPATIBLE SEALANT.
5.3 - SOUTH ENTRANCE VESTIBULE: REPLACE EXISTING SLIDING DOORS WITH NEW AUTOMATIC INSULATED GLASS SLIDING DOOR.
6.0 - SCOPE 6 - OPC BALLAST ROOF REPLACEMENT: (SEE A820 SERIES)
DEMOLITION: FOR THIS SCOPE OF WORK INCLUDES THE REMOVAL OF ALL BALLAST, BUILT-UP ROOFING MEMBRANE, WALK-WAY PADS, SHEATHING/COVER BOARDS, AND INSULATION DOWN TO CONCRETE ROOF DECK, AND REMOVE FLASHINGS AROUND PIPE AND DUCT PENETRATIONS. REMOVE SECTIONS OF ALUMINUM COPING TO ENABLE INSTALLATION OF NEW ROOFING MEMBRANE.
SALVAGE UNDAMAGED COPING SECTIONS FOR REINSTALLATION. AT AIR HANDLERS, EXPOSED MECHANICAL EQUIPMENT AND FANS, LIFT EXISTING FLASHING TO ALLOW FOR NEW ROOFING MEMBRANE AND FLASHING TO BE INSTALLED UP TO THE TOP OF THE CURB AROUND AIR HANDLERS, EXPOSED MECHANICAL EQUIPMENT AND FANS. REMOVAL SHALL BE DONE IN SECTIONS, COORDINATED WITH INSTALLATION OF NEW REPLACEMENT ROOF SO THAT ONLY A LIMITED PORTION OF THE ROOF IS EXPOSED AT ONE TIME. PROVIDE PROTECTION FOR INCLEMENT WEATHER OF EXPOSED AREAS DURING REROOFING. REMOVE BIRD PROTECTION TO AREA NORTH OF THE EXISTING PENTHOUSE. THOROUGHLY CLEAN PARAPETS, PENTHOUSE WALLS, EQUIPMENT, AND EXPOSED DUCT WORK ON THE NORTH SIDE OF THE PENTHOUSE, TO REMOVE BIRD EXCREMENT AND SANITIZE AREA AND AIR INTAKES. DISPOSE OF ALL MATERIALS IN ACCORDANCE WITH FEDERAL REGULATIONS AND LOCAL AND STATE REGULATORY REQUIREMENTS. PROVIDE FOR APPROPRIATE LEVEL OF INFECTION CONTROL DURING ALL PHASES OF
CONSTRUCTION.
NEW WORK: SHALL INCLUDE INSTALLATION OF COMPLETE NEW FULLY ADHERED SINGLE-PLY ROOFING SYSTEM INCLUDING VAPOR BARRIER ON CONCRETE SUBSTRATE, TAPERED ROOF INSULATION, SHEATHING, SINGLE-PLY (MINIMUM 60 MIL THICK) MEMBRANE, WALK-WAY PADS, STAINLESS STEEL FLASHINGS, PREFORMED FLASHINGS FOR PIPE AND DUNNAGE SUPPORT
PENETRATIONS, PIPE SUPPORTS, AND DUCT SUPPORTS.
INSTALL NEW BIRD PROTECTION DEVICES AND SCREENS WITH ACCESS DOOR TO AREA IDENTIFIED AROUND EQUIPMENT AND DUCTS ON THE NORTH SIDE OF THE PENTHOUSE. AT THE PARAPET PROVIDE NEW ALUMINUM COPING, FORMED AND PAINTED TO MATCH EXISTING, WHERE REMOVAL OF EXISTING COPING IS NOT SALVAGEABLE. MAINTAIN OPERATION OF ALL MECHANICAL
EQUIPMENT, VENTS, AND DEVICES ON ROOF DURING REROOFING.
7.0 - SCOPE 7 - BUILDING 1 WEST WING ROOF, BRIDGE ROOF & CHAPEL ROOF REPLACEMENT: (SEE A820 SERIES)
7.1 - REPLACE EXISTING ROOFING MATERIAL, ACCESSORIES WITH NEW SINGLE PLY ROOFING SYSTEM AND NEW
ACCESSORIES
DEMOLITION: FOR THIS SCOPE OF WORK DEMOLITION INCLUDES THE REMOVAL OF ALL BALLAST, BUILT-UP ROOFING MEMBRANE, WALK-WAY PADS, SHEATHING/COVER BOARDS, AND INSULATION DOWN TO CONCRETE ROOF DECK, AND REMOVE FLASHINGS AROUND PIPE AND DUCT PENETRATIONS. CUT BACK ROOFING AT PARAPETS VERTICALLY UP TO 30 INCHES ABOVE FINISHED ROOF SURFACE, PROTECT THROUGH-WALL FLASHING. AT AIR HANDLERS, EXPOSED MECHANICAL EQUIPMENT, FANS AND EQUIPMENT ROOMS LIFT EXISTING FLASHING TO ALLOW FOR NEW ROOFING MEMBRANE AND FLASHING TO BE INSTALLED UP TO THE TOP OF THE CURB AROUND AIR HANDLERS AND EQUIPMENT ROOMS. REMOVAL SHALL BE DONE IN SECTIONS, COORDINATED WITH INSTALLATION OF NEW REPLACEMENT ROOF SO THAT ONLY A LIMITED PORTION OF THE ROOF IS EXPOSED AT ONE TIME. PROVIDE PROTECTION FOR INCLEMENT WEATHER OF EXPOSED AREAS DURING REROOFING. DISPOSE OF ALL MATERIALS IN ACCORDANCE WITH FEDERAL REGULATIONS AND LOCAL AND STATE REGULATORY REQUIREMENTS. PROVIDE FOR APPROPRIATE LEVEL OF INFECTION CONTROL DURING ALL PHASES OF CONSTRUCTION. EXISTING DUNNAGE MAY BE LIFTED AND REMOVED IF
NO LONGER REQUIRED BY VA AFTER VERIFICATION WITH VA.
NEW WORK: NEW WORK INCLUDES INSTALLATION OF COMPLETE NEW ROOFING FULLY-ADHERED SINGLE-PLY SYSTEM INCLUDING VAPOR BARRIER ON CONCRETE SUBSTRATE, TAPERED ROOF INSULATION, SHEATHING, SINGLE- PLY (MINIMUM 60 MIL THICK) MEMBRANE, WALK-WAY PADS, STAINLESS STEEL FLASHINGS, PREFORMED FLASHINGS FOR PIPE AND DUNNAGE SUPPORT PENETRATIONS, PIPE SUPPORTS, ETC. AT THE PARAPET PROVIDE NEW STAINLESS STEEL FLASHING AND COUNTER FLASHING AT NEW CUT-IN REGLET AROUND ENTIRE PARAPET TO RECEIVE NEW ROOFING MEMBRANE FLASHING. MAINTAIN OPERATION OF ALL MECHANICAL EQUIPMENT, VENTS, AND
DEVICES ON ROOF DURING REROOFING.
AT THE SMALL AIR HANDLING UNIT, IDENTIFIED IN THE DRAWINGS, PROVIDE A NEW GALVANIZED SHEET METAL COVER OVER THE TOP OF THE ENTIRE UNIT. EDGES SHALL BE EXTENDED DOWN OVER THE FACE OF THE UNIT AND ALL SEAMS SHALL BE LAPPED AND SEALED. FASTEN COVER TO UNIT TO TOP OF UNIT OR STRAP DOWN TO PREVENT
UPLIFT OF COVER. ALL FASTENERS SHALL BE STAINLESS STEEL.
7.2 - REPLACE EXISTING ROOFING MATERIAL, ACCESSORIES WITH NEW SINGLE PLY ROOFING SYSTEM AND NEW
ACCESSORIES AT CHAPEL ROOF
DEMOLITION: FOR THIS SCOPE OF WORK INCLUDES THE REMOVAL OF ALL BALLAST, BUILT-UP ROOFING MEMBRANE, WALK-WAY PADS, SHEATHING/COVER BOARDS, AND INSULATION DOWN TO CONCRETE ROOF DECK, AND REMOVE FLASHINGS AROUND PIPE AND DUCT PENETRATIONS. REMOVE SECTIONS OF ALUMINUM COPING TO ENABLE INSTALLATION OF NEW ROOFING MEMBRANE. SALVAGE UNDAMAGED COPING SECTIONS FOR REINSTALLATION. AT AIR HANDLERS, EXPOSED MECHANICAL EQUIPMENT AND FANS, LIFT EXISTING FLASHING TO ALLOW FOR NEW ROOFING MEMBRANE AND FLASHING TO BE INSTALLED UP TO THE TOP OF THE CURB AROUND AIR HANDLERS, EXPOSED MECHANICAL EQUIPMENT AND FANS. REMOVAL SHALL BE DONE IN SECTIONS, COORDINATED WITH INSTALLATION OF NEW REPLACEMENT ROOF SO THAT ONLY A LIMITED PORTION OF THE ROOF IS EXPOSED AT ONE TIME. PROVIDE PROTECTION FOR INCLEMENT WEATHER OF EXPOSED AREAS DURING REROOFING. DISPOSE OF ALL MATERIALS IN ACCORDANCE WITH FEDERAL REGULATIONS AND LOCAL AND STATE REGULATORY REQUIREMENTS.
PROVIDE FOR APPROPRIATE LEVEL OF INFECTION CONTROL DURING ALL PHASES OF CONSTRUCTION.
NEW WORK: SHALL INCLUDE INSTALLATION OF COMPLETE NEW FULLY ADHERED SINGLE-PLY ROOFING SYSTEM INCLUDING VAPOR BARRIER ON CONCRETE SUBSTRATE, TAPERED ROOF INSULATION, SHEATHING, SINGLE-PLY (MINIMUM 60 MIL THICK) MEMBRANE, WALK-WAY PADS, STAINLESS STEEL FLASHINGS, PREFORMED FLASHINGS FOR
PIPE AND DUNNAGE SUPPORT PENETRATIONS, PIPE SUPPORTS, AND DUCT SUPPORTS.
7.2.1 EXPANSION JOINT BETWEEN CHAPEL ROOF AND OPC: REMOVE EXISTING EXPANSION JOINT COVER AND SEALANTS USED TO INSTALL THE EXPANSION JOINT COVER. REPLACE WITH NEW EXPANSION JOINT COVER FORMED FROM 16 GA (MIN. THICKNESS) 304 STAINLESS STEEL SHEET. FORM COVER JOINT TO ACHIEVE THE REQUIRED SEISMIC MOVEMENTS AND WITH PROPER SLOPE OF MINIMUM 5% AWAY FROM THE OPC TO THE CHAPEL ROOF.
INSTALL NEW EXPANSION JOINT COVER, ENSURING PROPER SEALED OVERLAP OF SECTIONS AND SEAL COVER JOINT
TO SUBSTRATES WITH COUNTER FLASHINGS AND PROPER EMBEDMENT IN COMPATIBLE SEALANT.
1.5 – FENESTRATION ASSEMBLIES: (SEE DETAIL SHEETS A808)
1.5.1 - CRACKED GLAZING UNITS: CRACKED GLAZING UNITS SHOULD BE REMOVED AND REPLACED WITH NEW INSULATED UNITS MATCHING ADJACENT UNITS FOR COLOR, TRANSLUCENCY AND THERMAL CHARACTERISTICS. PROVIDE NEW BLINDS.
1.5.2 - DETERIORATED AND MISSING SEALANT: REMOVE FAILED SEALANT FROM JOINTS. CLEAN OUT JOINTS IN WINDOW ASSEMBLIES, TO ALLOW INSTALLATION OF NEW SEALANT. INSTALL SEALANT FOLLOWING RECOMMENDATIONS OF SEALANT
MANUFACTURER FOR PRIMERS, BACKER MATERIAL AND SEALANT TYPE.
1.5.3 - DETERIORATED AND DISLODGED GASKETS: REMOVE ANY DETERIORATED GASKETS FROM THE WINDOW FRAME AND REPLACE WITH NEW GASKET, SELECTED FOR COMPATIBILITY, SIZE AND DUROMETER TO FORM A COMPLETED SEAL OF THE GLAZING UNITS IN THE FRAMING. WET SEAL REPLACEMENT FOR GASKETS SHOULD NOT BE CONSIDERED. REINSTALL DISLODGED GASKETS IF THE GASKET MAINTAINS THE REQUIRED COMPRESSION UNDER THE COLDEST EXPERIENCED ENVIRONMENT. FOLLOW RECOMMENDATIONS OF GASKET AND WINDOW MANUFACTURER AND AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) FOR GASKET SELECTION, SUBSTRATE PREPARATION, AND INSTALLATION.
1.5.4 – DETERIORATED LOUVERS: REMOVE LOUVER AND REPLACE WITH NEW ALUM STORMPROOF LOUVER WITH SAME FREE
AREA CAPACITY.
1.5.5 – DETERIORATED METAL SUNSHADES: REMOVE ALL LOOSE COATINGS FROM SUNSHADES AND DETERIORATED SEALANTS.
PREPARE SURFACE TO RECEIVE NEW FINISH. PROTECT ALL SURFACES OF ADJACENT MATERIALS FROM NEW FINISH. APPLY 3 COAT PAINT SYSTEM TO METAL SUNSHADES. INSTALL NEW SEALANT TO JOINTS IN METAL SUNSHADES AND BETWEEN
SUNSHADES AND ADJACENT CLADDING.
1.6 - MISCELLANEOUS: (SEE DETAIL SHEETS A809)
1.6.1 - ACTIVE MOISTURE LEAKS: HOSE TEST AREA WHERE ACTIVE MOISTURE LEAKS OCCUR TO DETERMINE THE SOURCE AND EXTENT OF MOISTURE INGRESS. REMOVE CLADDING MATERIALS, MAKE REPAIRS TO CLADDING MATERIAL AND REINSTATE MATERIAL. REPAIR DAMAGED FLASHINGS, MOISTURE BARRIERS AND/OR INTERNAL SEALS. REPLACE MATERIALS AS REQUIRED TO
IMPLEMENT REPAIR. RETEST AREA OF LEAKS TO PROVE THE EFFICACY OF THE REPAIR.
USE REPAIR MATERIALS COMPATIBLE WITH ADJACENT MATERIALS TO AVOID FURTHER UNINTENDED DETERIORATION OF MOISTURE BARRIER SYSTEM. FOLLOW THE RECOMMENDATION OF THE CLADDING-SYSTEM’S INDUSTRY ASSOCIATION
STANDARDS AND RECOMMENDATIONS.
1.6.2 - ABANDONED ANCHORS: REMOVE ABANDONED ANCHORS FROM CLADDING AND REPAIR THE VOID LEFT BY THE ANCHOR, USING THE REPAIRS NOTED IN 1.2.5 IN TERRA COTTA PANELS AND UNITS FOR UNSEALED CUTS.
1.6.3 - METAL DECK TO TERRA COTTA TRANSITIONS: AT THE LOADING DOCK OF BUILDING 1, REPAIR TRANSITION BETWEEN METAL DECK TO TERRA COTTA CLADDING. REPAIR VOID BY INSTALLING AN INSULTING MATERIAL AND A PAINTED METAL TRANSITION COVER OVER THE INSULATION. SEAL ALL JOINTS IN THE TRANSITION COVER. FINISH OF TRANSITION COVER TO MATCH ADJACENT
METAL DECK.
1.6.4 - DAMAGED CLAY TILES: REMOVE AND REPLACE DAMAGED CLAY TILES AT THE ARCADE ON THE SOUTH ELEVATION OF
BUILDING 1, TILE SHALL MATCH EXISTING TILE, REGROUT JOINTS.
1.6.5 - EIFS WALL SEPARATION: WHERE EIFS WALL SYSTEM IS FAILING, REMOVE ENTIRE AREA OF EIFS WALL SYSTEM DOWN TO SUBSTRATE. INSPECT SUBSTRATE FOR DAMAGE AND PATCH AND REPAIR SUBSTRATE AS REQUIRED TO INSTALL NEW EIFS SYSTEM WITH INTEGRAL DRAINAGE LAYER, OVER NEW AIR BARRIER. USE INSULATION WITH A THICKNESS TO ALIGN FINISHED FACE OF EIFS SYSTEM WITH SURROUNDING TERRA COTTA PANELS. COLOR AND TEXTURE OF FINISHED EIFS SURFACE SELECTED
TO MATCH SURROUNDING TERRA COTTA PANELS.
1.6.6 - CLEAN AND REPAIR METAL AWNING: CLEAN ALL SURFACES OF METAL AWNING TO RECEIVE NEW FINISH. REPAIR OR REPLACE METAL SECTIONS OF AWNING TO RESTORE AWNING TO ITS ORIGINAL SHAPE AND GEOMETRY. PAINT AWING, APPLYING
PRIMER AND FINISH COATINGS. FINISH TO MATCH UNDERSIDE OF ADJACENT CANOPY.
1.6.7 - CLEAN & PAINT THE OUTSIDE OF THE ELEVATOR MACHINE ROOM PENTHOUSES: THOROUGHLY CLEAN EXTERIOR STUCCO SURFACE OF THE ELEVATOR MACHINE ROOM PENTHOUSE, REMOVING LOOSE OR PEELING FINISHES DOWN TO SOUND SUBSTRATE OR FULLY ADHERED FINISHES. PAINT BY APPLY PRIMER AND FINISH COAT(S). FINISH TO MATCH EXISTING
PENTHOUSE COLOR.
1.6.8 - CLEAN & PAINT METAL PANELS OF OPC LEVEL 1: CLEAN METAL PANEL ABOVE AND BELOW WINDOW. REMOVE ANY LOOSE PAINT. PAINT BY APPLY PRIMER AND FINISH COAT(S). COLOR AND GLOSS TO MATCH EXISTING METAL PANEL FINISH.
MASTER KEYNOTE LIST
1.0 SCOPE 1
1.2 TERRA COTTA CLADDING
1.2.1 UNSOUND OR CRACKED TERRA COTTA UNITS & SIGNIFICANTLY
CRACKED TERRA COTTA PANELS
1.2.2 TERRA COTTA PANEL CRACKS
1.2.3.A TERRA COTTA SILL SPALL
1.2.3.B TERRA COTTA PANEL SPALL
1.2.3.C TERRA COTTA COPING STONE SPALL
1.2.4 LOOSE, DETERIORATED & MISSING MORTAR JOINTS
1.2.5 UNSEALED CONSTRUCTION CUTS IN TERRA COTTA UNITS
1.2.6 EFFLORESCENCE STAINING & STAINING IN TERRA COTTA UNITS
1.2.7 DETERIORATED OR MISSING SEALANT
1.2.8 EXTERIOR COATING DETERIORATION
1.3 STUCCO CLADDING
1.3.1 STUCCO SPALLS
1.3.2 STUCCO CRACKS
1.3.3 FAILED AND DELAMINATING STUCCO CLADDING
1.3.4 STAINS IN STUCCO CLADDING
1.4 CONCRETE WALLS AND BUILDING ELEMENTS
1.4.1 CONCRETE SPALLS
1.4.2 CONCRETE CRACKS
1.4.3 DETERIORATED OR MISSING SEALANT
1.4.4 FAILED CONCRETE COATING
1.5 FENESTRATION ASSEMBLIES
1.5.1 CRACKED GLAZING UNITS
1.5.2 DETERIORATED OR MISSING SEALANT
1.5.3 DETERIORATED OR DISLODGED GASKETS
1.5.4 DETERIORATED LOUVERS
1.5.5 DETERIORATED METAL SUNSHADES
1.6 MISCELLANEOUS
1.6.1 ACTIVE MOISTURE LEAKS
1.6.2 ABANDONED ATTACHMENT ANCHORS
1.6.3 METAL DECK TO TERRA COTTA TRANSITION
1.6.4 DAMAGED CERAMIC TILES AT COLONNADE
1.6.5 EIFS WALL SEPARATION
1.6.6 CLEAN AND REPAIR METAL AWNING
1.6.7 CLEAN & PAINT OUTSIDE OF ELEVATOR PENTHOUSES
1.6.8 CLEAN & PAINT METAL PANELS OF OPC LEVEL 1
2.0 SCOPE 2
2.1.1 REPLACE SINGLE-GLAZED WINDOWS AND STOREFRONT WITH
DOUBLE GLAZING
2.1.2 REPLACE EXISTING DOUBLE GLAZED WINDOWS
3.0 SCOPE 3
4.0 SCOPE 4
5.0 SCOPE 5
5.1 REPLACE EXISTING NORTH VESTIBULE SLIDING DOOR WITH NEW
5.2 REPLACE EXISTING EAST VESTIBULE SLIDING DOOR WITH NEW
5.2.1 REPAIR FLASHING BETWEEN CANOPY AND VESTIBULE ROOF
5.3 REPLACE EXISTING SOUTH VESTIBULE SLIDING DOOR WITH NEW
6.0 SCOPE 6
7.0 SCOPE 7
7.1 REPLACE EXISTING ROOFING MATERIAL AND ROOF
ACCESSORIES OF BUILDING 1 WEST WING
7.2 REPLACE ROOFING MATERIALS AND ROOF ACCESSORIES OF
SECOND FLOOR CHAPEL ROOF
7.2.1 EXPANSION JOINT BETWEEN CHAPEL ROOF AND OPC.
NOTES: REFER TO RELEVANT SPECIFICATIONS FOR BASIS OF DESIGN,
WORKMANSHIP AND OTHER REQUIREMENTS.
BASE BID
ADD ALTERNATE 1
ADD ALTERNATE 2, 3
ADD ALTERNATE 2: BUILDING 1 WEST WING ROOF REPLACEMENT
ADD ALTERNATE 3: BUILDING 1 CHAPEL ROOF AND BRIDGE ROOF REPLACEMENT
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% NOT FOR CONSTRUCTION
BID DOCUMENTS
Office of Construction &
Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT / ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
570-21-108VA CENTRAL CALIFORNIA HEALTH CARE SYSTEM
REPAIR EXTERIOR FINISHES BLDG 1 & OPC
2615 EAST CLINTON AVENUE
FRES…