2-26-012 - WCL PVB Roof Screen RFP Set.pdf
PDF 4 MB Posted
- Attached to
- Pleasant Valley Library Roof Screen RFP
- Solicitation number
- 26-162
- Issued by
- Weber County, Utah
About this file
This is a Request for Proposal (RFP) document from the Weber County Library Board of Directors for the installation of a screen wall at the Pleasant Valley Branch Library located at 5568 S Adams Ave, Washington Terrace, Utah 84405. The project requires a qualified, licensed service provider to construct and install the screen wall according to detailed drawings and specifications provided in the Project Manual, which is available on the Bonfire platform. A mandatory pre-submittal meeting is scheduled for 12:00 p.m. on Tuesday, June 16, 2026, at the Pleasant Valley Branch Library, where interested bidders must attend to review the RFP requirements and participate in a project tour. All questions and inquiries following the mandatory pre-submittal meeting must be submitted through the Bonfire portal, with answers provided via the same platform. Electronic bid submissions must be received through Bonfire no later than 2:00 p.m. on Thursday, June 25, 2026.
The RFP document does not specify pricing information, set-asides, incumbent contractor details, funding sources, or contract term and renewal options in the available materials. Interested bidders should consult the complete Project Manual and detailed drawings posted on Bonfire for comprehensive project specifications, pricing requirements, and any additional terms and conditions governing this procurement.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 3-WCL PVB ROOF SCREEN PROJECT MANUAL.pdf | ||
| 1-RFP Pleasant Valley Branch Roof Screen 06 09 2026.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
B
C
D
X
AX.X
X
AX.X
A1
AX.X
X
1 1
SYMBOLS
XXX
OFFICE
INDICATES FINISHED
GLAZED MASONRY WALL
INDICATES PAGE NO.
INDICATES SECTION NO.
INDICATES DETAIL NO.
INDICATES PAGE NO.
INDICATES GRID NUMBER
INDICATES ROOM NAME
INDICATES ROOM NUMBER
KEYNOTE
REVISIONS
FLOOR TYPE
A
METAL OR METAL STUDS
MASONRY WALL
WOOD WALL
FINISHED WOOD
BLOCKING
CONTINUOUS WOOD
RIGID INSULATION
BATT INSULATION
INDICATES WALL TYPE
INDICATES OBJECT
DOOR NUMBER
INDICATES ELEVATION NO.
INDICATES PAGE NO.
INDICATES ELEVATION
WINDOW NUMBER
INDICATES GLASS TYPE
GYP. BD., CONC. OR
DIMENSION TO FACE OF
DIMENSION TO CENTER
MASONRY
LINE
OBJECT
ELEVATION
CONCRETESTONE
CL
WASHINGTON
HEIGHTS
MEMORIAL
PARK
FRIENDSHIP
PARK
OGDEN
REGIONAL
MEDICAL
CENTER
LION
PARKS
WASHINGTON
TERRACE
OGDEN GOLF AND
COUNTRY CLUB
CLUB
HOUSE
PARK
W
AS
HI
NG
TO
N
TE
RR
AC
E
RD
RHOMER
PARK
W
AS
H
IN
G T
BL
VD
WASHINGT BLVD.
AD
AM
S
AV
E
PK
W Y
W
AL
L
AV
E.
RIV
ER
DAL
E
RD.
CHIMES VIEW DR.
40TH ST
40TH ST COUNTRY HILLS DR.
36TH ST36TH ST
W 44TH S
S
W
W RIVERDALE RD.
S W
EB
ER
D R
RIVERDALE
PARK
GOLDEN
SPIKE PARK
S
TH
W
S
W
SOUTH OGDEN
RIVERDALE
CENTRAL PARK
PROJECT SITE
TE
L:
1.5
.91
SA
LT
L
AK
E C
ITY
UT
AH
W
ES
T P
IE
RP
ON
T
A
VE
SH
EE
T N
O.
DA
TE
DR
AW
N
BY
PR
OJ
EC
T N
O.
TH
ES
E D
O C
U M
EN
TS
A R
E
IN
ST
R U
M
EN
TS
O
F S
ER
VI
C E
AN
D
SH
AL
L R
EM
AI
N T
H E
PR
O
PE
R
TY
O
F T
H E
AR
C
H
IT
EC
T.
N O
U
SE
O R
R E-
U
SE
O F
TH
ES
E D
O C
U M
EN
TS
L
BE
P
ER
M
IT
TE
D U
N
LE
SS
AU
TH
O R
IZ
ED
IN
W
R
IT
IN
G
B Y
PR
ES
C O
TT
M
U
IR
A R
C H
IT
EC
T W
IT
H
A
PP
R O
PR
IA
TE
C
O M
PE
N
TI
O
N . C
O
PY
R
IG
H T
PR
ES
CO
TT
M
UI
R
A
SS
OC
IA
TE
S, A P
RO
FE
SS
IO
NA
L C
OR
PO
RA
TIO
N
R O O F
SC
R
EE
N
TI
TL
E
SH
EE
T
T1
WEBER COUNTY LIBRARY
PLEASANT VALLEY BRANCH -
5568 S ADAMS AVE.
WASHINGTON TERRACE, UT
06.09.26
RFP, REQUEST FOR PROPOSAL SET
NM
.09 .26
.00
W
EB
ER
C O U N
TY
L
IB
R A R Y
S A D A M S A
VE
W A
SH
IN
G
TO
N T
ER
R A C E, U T
PL
EA
SA
N T
VA
LL
EY
B R A N C H
A1.3 ROOF PLAN
A2.1 EXTERIOR ELEVATIONS
A3.1 BUILDING SECTIONS
A5.1 DETAILS
A5.2 DETAILS
T1 TITLE SHEET
INDEX OF DRAWINGS
ABBREVIATIONS
F.O. FACE OF
M.R.
P.C.J.
SIM.
R.D.
N.I.C.
SIMILAR
ROOF DRAIN
PLASTER CONSTRUCTION
JOINT
NOT IN CONTRACT
MOISTURE RESISTANTANCHOR BOLT
CONTROL JOINT
CATCH BASIN
ADJUSTABLE
CONCRETE
A.B.
C.B.
ADJ.
C.J.
A.C.
CONC.
ASPHALTIC CONCRETE
T.W.
S. STL.
T.O.C.
U.N.O.
V.C.
TYP.
T.O.W.
T.O.S.
UNLESS NOTED OTHERWISE
VINYL COMPOSITION
TYPICAL
TOP OF WALL
TOP OF STEEL
TOP OF WALK
STAINLESS STEEL
TOP OF CONCRETE
WITHW/
EXPANSION JOINT
DIFFUSER
EQUAL
FINISH FLOOR
FLOOR DRAIN
EXTERIOR
EXISTING
ELEVATION
DIF.
E.J.
EQ.
F.F.
F.D.
EXT.
EL.
EXIST.
INTERIOR
GYPSUM BOARD
FIRE TREATEDF.T.
INT.
GYP.BD.
F.S.R. FLEXIBLE SHEET ROOFING
CONTINUOUSCONT.
STEELSTL.
NO. SHEET TITLE
V.I.F. VERIFY IN FIELD
PROJECT SUMMARY
PRESCOTT MUIR & ASSOCIATES
171 WEST PIERPONT AVENUE
SALT LAKE CITY, UT 84101
801.521.9111 FAX 801.521.9158
WEBER COUNTY LIBRARY
2464 JEFFERSON AVENUE
OGDEN, UT, 84401
801.337.2618 FAX 801.337.2615
STRUCTURAL ENGINEER
ARCHITECT
OWNER PROJECT SCOPE OF WORK:
1. NEW ROOF SCREEN WALL AT AIR HANDLER UNITS &
CONDENSING TOWER
*NEW ROOF MEMBRANE OVERLAY SCOPE SHOWN FOR
REFERENCE. COORDINATE ROOF FLASHING WITH ROOF
OVERLAY CONTRACTOR.
BUILDING AREA: EXISTING TO REMAIN, NO MODIFICATIONS
MAIN LEVEL GROSS AREA: 33,480 S.F.
SECOND LEVEL GROSS AREA: 259 S.F.
TOTAL GROSS BUILDING AREA: 33,739 S.F.
PARKING: EXISTING TO REMAIN, NO MODIFICATIONS
ARCHITECTURAL
T.O. TOP OF
BOTTOM OFB.O.
STRUCTURAL
NOTE:
THE CONTRACT DOCUMENTS ARE BASED ON PRELIMINARY REACTION STRUCTURAL LOADS
PROVIDED BY THE BASIS OF DESIGN SCREEN WALL VENDOR. ONCE THE PROJECT IS BID AND
AWARDED TO A SPECIFIC SCREEN WALL VENDOR, THE VENDOR WILL PROVIDE FINAL COMPLETE
CALCULATIONS AND LAYOUT FOR DOCUMENTATION AND REVIEW BY THE LOCAL AHJ & DESIGN
TEAM.
DEFERRED SUBMITTALS DESIGN AND CODE CRITERIA
MEMO, DATED 04.10.2026 SEE STRUCTURAL MEMO IN PROJECT MANUAL
ARW STRUCTURAL ENGINEERS
1594 PARK CIRCLE
OGDEN, UT, 84404
801.782.6008 FAX 801.782.4656
APPLICABLE CODES:
INTERNATIONAL EXISTING BUILDING CODE 2021
INTERNATIONAL BUILDING CODE 2021
INTERNATIONAL FIRE CODE 2021
A. OCCUPANCY AND GROUP: A-3
MIXED OCCUPANCY YES
B. SEISMIC & WIND CRITERIA: RE: STRUCTURAL MEMO
C. TYPE OF CONSTRUCTION: IIB
D. EXISTING ROOF ASSEMBLY FIRE RATING: 0HR
E. FIRE SPRINKLERS: YES
ZONING:
NEIGHBORHOOD COMMERCIAL C-1
WASHINGTON TERRACE MUNICIPAL CODE:
17.29.70: ARCHITECTURAL DESIGN STANDARDS
REQUIRED:
NEW BUILDING OR REMODELING OF AN EXISTING
BUILDING SHALL USE CLASS A TYPE FIRE RESISTANT
ROOFING MATERIAL OR A COLORED METAL
COMMERCIAL GRADE ROOFING MATERIAL; THE MILL
FINISH (NONCOLORED) ALUMINUM METAL ROOFING
MATERIAL UNLESS SPECIFICALLY REQUESTED BY
THE APPLICANT AND APPROVED BY THE PLANNING
COMMISSION/CITY COUNCIL SHALL NOT BE USED.
PROPOSED:
NEW TPO ROOF MEMBRANE OVERLAY AND NEW KYNAR
COATED METAL VERTICAL ROOF SCREEN PANEL SYSTEM,
RE: EXTERIOR ELEVATIONS.
1. ROOF SCREEN MANUFACTURER DELEGATED STRUCTURAL DESIGN & CALCULATIONS:
THE ROOF SCREEN VENDOR SHALL PROVIDE FRAME LAYOUT, PROJECT-SPECIFIC DETAILS OF
ATTACHMENT TO THE EXISTING ROOF STRUCTURE, AND COMPLETE STRUCTURAL
CALCULATIONS.
NOT TO SCALEVICINITY MAP
ROOF SCREEN
17'-4" 13'-4" 19'-8" 5" 30'-11 1/4" 17'-8 3/4" 21'-4" 5'-4" 25'-10 1/2" 26'-6" 14'-11 1/2" 11'-9" 27'-3"
8.6
8.6
5.8
5.8
2.9
2.9
AA
BB
CC
DD
EE
E.3E.3
A.1A.1
B.9B.9
5'- 2"
9'-
7'-
6"
'-6
8'- 0"
'-8
'-2 1/
4"
'-2
'-1
1 3 /4"
4 1 /4"
'-8
'-3 3/
4" 1'-
8"
FF
1.6
1.6
12 32
GG
G.6G.6
HH
H.7H.7
JJ
MECHANICAL ROOF DECK BEARING
116'-4 1/2"
LINE OF STEP
IN ROOF
LINE OF STEP
IN ROOF
A2.1
A2.1
A3.1
A3.1
HIGH DECK BEARING
121'-6 1/8"
T.O. FLASHING
122'-11 1/4"
T.O. FLASHING
130'-3 1/4"
SLOPE 1/4" : 1'-0" MIN.
LOW DECK BEARING
120'-7 1/4"
6 6
SL
OP
E 1/4
1'
-0 " M
IN
HIGH DECK BEARING
128'-4 1/2"
LOW DECK BEARING
127'-4 1/8"
T.O. FLASHING
130'-3 1/4"
T.O. FLASHING
127'-9 1/2"
DECK BEARING
127'-1"
DECK BEARING @ GRID A.1
118'-1"
DECK BEARING @ GRID B
114'-8"
DECK BEARING @ COLUMN
117'-8"
STRUCTURAL VALLEY
6 6
13 TYP.
13 TYP.
13 TYP.
13 TYP.
13 TYP.
13 TYP.
A3.1
A3.1
A5.1
13 TYP. 13 TYP.
'-0
" V .I.F
VALLEY
RIDGE
SL
OP
E
SL
OP
E
SL
OP
E
TYP.
DECK BEARING @ GRID E.3
114'-8"
162'- 1 3
/4" V
.I.F
169'-10"
171621
SL
OP
E
A5.1
SIM
A5.1
SIM
A5.2
A5.1LOW
A5.1
LOW
A5.1
SIM
A5.1
A5.18
A5.1
A5.1
23227
A5.2
A5.2
A5.2
A5.1
A5.1
A5.1
A5.1
A5.2
A5.1
A5.1 LOW
A5.1 MASONRY
SIM.
A5.1 SIM.14
A5.1SIM.
A5.1 SIM.
A5.1 LOW
A5.2
A5.1
A5.1
A5.1
A5.1
A5.1LADDER
V.
I.F
5'-
0"
FR
AM
E
SP
AN
11 11
7 66
13 TYP.
AHU AHU
13 TYP.
TYP.
13 TYP.
TYP.
4 TYP. 20 TYP.
TYP.
TYP.
4 TYP.
TYP.
V.I.F.
5'-8 3/4" POST SPAN
A5.2
A5.2
A5.2
'-7
3/ 4"
A5.2
1'- 8"
SIM
FRAME SPAN, VARIES
5'-10 1/2"
5'- 4"
P
OS
T S
PA
N
NEW FULLY ADHERED
TPO ROOF MEMBRANE
OVERLAY
EXISTING ROOF
MEMBRANE, CLEAN,
CUT IN A 10'-0" X 10'-0"
GRID, AND PREPARE
PER MANUFACTURER
WARRANTY
REQUIREMENTS
EXISTING ROOF
INSULATION TO REMAIN
NEW FULLY ADHERED
TPO ROOF MEMBRANE
OVERLAY
EXISTING ROOF
MEMBRANE, CLEAN,
CUT IN A 10'-0" X 10'-0"
GRID, AND PREPARE
PER MANUFACTURER
WARRANTY
REQUIREMENTS
EXISTING ROOF
INSULATION TO REMAIN
EXISTING ROCK BALLAST,
1/3 OF BALLAST TO BE
PLACED EVENLY OVER
EXISTING ADJACENT
ROOF AT A TIME TO AVOID
OVERLOADING THE
EXISTING ROOF
STRUCTURE
TE
L:
1.5
L
AK
E C
ITY
W
ES
T P
IE
RP
ON
T
A
VE
SH
EE
T N
O.
DA
TE
DR
AW
N
BY
PR
OJ
EC
T N
O.
TH
ES
E D
O C
U M
EN
TS
A R
E
IN
ST
R U
M
EN
TS
O
F S
ER
VI
L R
EM
AI
N T
H E
PR
O
PE
R
TY
O
F T
H E
AR
C
H
IT
EC
T.
N O
U
SE
O R
R E-
U
SE
O F
TH
ES
E D
O C
U M
L
BE
P
ER
M
IT
TE
D U
N
O R
IZ
ED
IN
W
R
IT
IN
G
B Y
PR
ES
C O
TT
M
U
IR
A R
C H
IT
EC
T W
IT
H
A
PP
R O
PR
IA
TE
C
O M
O
N . C
O
PY
R
IG
H T
PR
ES
CO
TT
M
UI
R
A
SS
OC
IA
TE
S, A P
RO
FE
SS
IO
NA
L C
OR
PO
RA
TIO
N
R O O F O
VE
R
LA
Y
RO
OF
P
LA
N
A 1.
NM
.09 .26
.00
W
EB
ER
C O U N
TY
L
IB
R A R Y
S A D A M S A
VE
W A
SH
IN
G
TO
N T
ER
R A C E, U T
PL
EA
SA
N T
VA
LL
EY
B R A N C H
1/8" = 1'-0"
1 EXISTING COOLING TOWER TO REMAIN
2 EXISTING AIR HANDLING UNIT TO REMAIN
3 EXISTING ROOF HATCH TO REMAIN, EXTEND
NEW ROOF MEMBRANE OVERLAY UNDER ROOF
HATCH FLASHING
4 NEW TPO WALKWAY PADS
5 NEW MECHANICAL ROOF SCREEN, RE:
ELEVATIONS & DETAILS
6 EXISTING TAPERED RIGID INSULATION CRICKET
7 EXISTING PRIMARY ROOF DRAIN TO REMAIN
8 REMOVE EXISTING CAP, INSTALL NEW
MEMBRANE, AND REPLACE EXISTING CAP
OVER MEMBRANE
9 EXISTING SCUPPER TO REMAIN
10 EXISTING ROOFTOP MECHANICAL DUCTS TO
REMAIN, SHOWN DASHED
11 ACCESS GATE IN MECHANICAL ROOF SCREEN
12 NEW FULLY ADHERED ROOF MEMBRANE
OVERLAY, RE: ROOF OVERLAY TYPE 1,
COORDINATE EXACT LOCATION WITH AHU
ACCESS AND OWNER APPROVAL
13 NEW CONTINUOUS STRIP FLASHING
14 NEW FULLY ADHERED ROOF MEMBRANE
OVERLAY BELOW ROCK BALLAST, RE: ROOF
OVERLAY TYPE 2, 1/3 OF BALLAST TO BE
PLACED EVENLY OVER EXISTING ADJACENT
ROOF AT A TIME TO AVOID OVERLOADING THE
EXISTING ROOF STRUCTURE
15 NEW PAINTED STEEL LADDER, RE: DETAIL
16 EXISTING VENT
17 EXISTING EXHAUST FAN
18 FACE OF BUILDING BELOW SHOWN DASHED
19 REMOVE AND REPLACE EXISTING TPO
WALKWAY PADS
20 NEW ROOF SCREEN FRAME SHOWN DASHED,
RE: ROOFSCREEN MFR.
21 REMOVE EXISTING METAL FLASHING AND
SEALANT JOINT, EXTEND NEW ROOF
MEMBRANE UP MASONRY AND REINSTALL
FLASHING AND SEALANT JOINT
22 EXISTING SCUPPER TO REMAIN, EXTEND
OVERLAY THROUGH OPENING, TIE INTO
EXISTING FLASHING
23 REMOVE AND REPLACE SPLASH BLOCK ONTO
NEW OVERLAY
24 NEW ROOF SCREEN POST, RE: DETAIL
ROOF PLAN KEYED NOTES
ROOF OVERLAY TYPES
ROOF PLAN GENERAL NOTES
1. AT LOCATIONS WHERE DECK IS SCHEDULED TO BE
EXPOSED, NO FASTNERS SHALL BE ALLOWED TO
PENETRATE DECK. ANY DECK PENETRATION WILL BE
REQUIRED TO BE REPAIRED AT NO EXPENSE TO THE
OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE
TO REVIEW THE CEILING PLAN FOR LOCATIONS OF
FINISH EXPOSED DECK AND VERIFY ANY
DISCREPANCIES WITH THE ARCHITECT PRIOR TO
COMMENCEMENT OF WORK.
2. REFER TO DETAIL REGARDING TYPICAL
FLASHING DETAIL AT ROOF PENETRATIONS.
3. REMOVE ALL EXISTING TPO WALKWAY PADS, CLEAN
AND PREP EXISTING ROOF MEMBRANE TO RECEIVE
NEW ROOF MEMBRANE OVERLAY PER
MANUFACTURER'S WARRANTY REQUIREMENTS.
4. CONTRACTOR TO VERIFY LOCATIONS OF ALL
EXISTING ROOF MOUNTED EQUIPMENT AND ACCESS
DOORS TO AHU AND COORDINATE W/ ROOF SCREEN
VENDOR TO PROVIDE UNOBSTRUCTED ACCESS FOR
ALL REQUIRED MAINTENANCE.
5. VERIFY IN FIELD EXACT ROOF FRAMING LOCATIONS
AND COORDINATE WITH SCREEN VENDOR FOR NEW
SCREEN POST LOCATIONS.
6. ROOF SCREEN SYSTEM, INCLUDING FRAME AND POST
LOCATIONS ARE SHOWN BASED ON PRELIMINARY
LOAD CALCULATIONS AND ARE SUBJECT TO CHANGE
BASED ON FINAL SCREEN WALL DELEGATED DESIGN.
7. GRIDLINES AND GRID DIMENSIONS
SHOWN BASED ON RECORD DRAWINGS.CONTRACTOR
TO VERIFY ALL DIMENSIONS IN FIELD.
1.
25 RELOCATE / ADJUST PLACEMENT OF EXISTING
ROOF VENT PIPING OR FLUE TO
ACCOMMODATE NEW ROOF SCREEN FRAME.
26 NEW CONTINUOUS HEAT TRACE SHOWN
HATCHED SURFACE MOUNTED TO T.O. SHEET
METAL KNIFE EDGE, HOLD BACK FROM EDGE
MIN. 1/2", CONCEAL FROM VIEW BELOW, REFER
TO ALTERNATES IN PROJECT MANUAL
2.
FINISH FLOOR
100'-0"
1091 2 3 4 5 6 7 8.685.82.91.6
T.O. MASONRY (HIGH)
130'-0"
T.O. CONTROL ROOM FLASHING
/ T.O. ROOF SCREEN
127'-9 1/2"
T.O. CONTROL ROOM FLASHING
/ T.O. ROOF SCREEN
127'-9 1/2"
DECK BEARING @ GRID G
118'-0"
DECK BEARING @ GRID E.3, B
114'-8"
5 61
T.O COOLING TOWER
133'-8 5/8"
ROOF SCREEN BEYOND SHOWN DASHED
A3.1
3 5
TYP. TYP.
10 4 10 7
FINISH FLOOR
100'-0"
ABCDEE.3 A.1B.9FGG.6HH.7J
T.O. MASONRY (HIGH)
130'-0"
T.O. MASONRY (HIGH)
130'-0"
T.O. CONTROL ROOM FLASHING
/ T.O. ROOF SCREEN
127'-9 1/2"
DECK BEARING @ GRID G
118'-0"
DECK BEARING @ GRID E.3, B
114'-8"
T.O COOLING TOWER
133'-8 5/8"
3 7
A3.1
5 89
A5.1
TYP.
1'-0" MIN.
A5.1
A5.1
A5.1
A5.1
TE
L:
1.5
L
AK
E C
ITY
W
ES
T P
IE
RP
ON
T
A
VE
SH
EE
T N
O.
DA
TE
DR
AW
N
BY
PR
OJ
EC
T N
O.
TH
ES
E D
O C
U M
EN
TS
A R
E
IN
ST
R U
M
EN
TS
O
F S
ER
VI
L R
EM
AI
N T
H E
PR
O
PE
R
TY
O
F T
H E
AR
C
H
IT
EC
T.
N O
U
SE
O R
R E-
U
SE
O F
TH
ES
E D
O C
U M
L
BE
P
ER
M
IT
TE
D U
N
O R
IZ
ED
IN
W
R
IT
IN
G
B Y
PR
ES
C O
TT
M
U
IR
A R
C H
IT
EC
T W
IT
H
A
PP
R O
PR
IA
TE
C
O M
O
N . C
O
PY
R
IG
H T
PR
ES
CO
TT
M
UI
R
A
SS
OC
IA
TE
S, A P
RO
FE
SS
IO
NA
L C
OR
PO
RA
TIO
N
R O O F O
VE
R
LA
Y
EX
TE
RI
OR
E
LE
VA
TI
ON
S
A 2.
AH
.09 .26
.00
W
EB
ER
C O U N
TY
L
IB
R A R Y
S A D A M S A
VE
W A
SH
IN
G
TO
N T
ER
R A C E, U T
PL
EA
SA
N T
VA
LL
EY
B R A N C H
ELEVATION GENERAL NOTES
- ELEVATION KEYED NOTES
1 NEW MECHANICAL ROOF SCREEN,
SMOOTH FLUSH 1" PROFILE,
KYNAR COATED STEEL TO MATCH
COLOR OF EXIST. SHEET METAL,
12" VERTICAL PANEL, B.O.D., RE:
PROJECT MANUAL FOR
ALTERNATE PANEL TYPES
2 NEW ROOF SCREEN BASE
SUPPORTS ATTCHED TO EXISTING
ROOF STRUCTURE, RE: SECTIONS
& DETAILS
3 NEW ROOF SCREEN FRAME
BEYOND SHOWN DASHED,
4 NEW ROOF SCREEN HORIZONTAL
FRAME HAT SECTIONS. SHOWN
DASHED BEYOND.
5 EXISTING AIR HANDLING UNIT TO
REMAIN. SHOWN DASHED BEYOND
6 EXISTING COOLING TOWER TO
REMAIN
7 EXISTING SHEET METAL COPING
TO BE REMOVED AND
REINSTALLED. TO ACCOMODATE
NEW ROOF MEMBRANE, RE: ROOF
PLAN & DETAILS
SCALE 1/8" = 1'-0"2
SCALE 1/8" = 1'-0"1
8 NEW POWDER COATED STEEL
LADDER, RE: DETAILS
A. FIELD VERIFY ALL DIMENSIONS
INCLUDING ELEVATIONS
B. REFER TO PROJECT MANUAL FOR
ALTERNATE ROOF SCREEN OPTIONS.
9 EXISTING MECHANICAL ROOF
DUCTS BEYOND TO REMAIN
10 GATE IN ROOF SCREEN, RE:ROOF
PLAN, COORDINATE EXACT
LOCATION WITH OWNER &
ARCHITECT
FINISH FLOOR
100'-0"
A B C D E E.3A.1 B.9 F G G.6 H H.7 J
T.O. CONTROL ROOM FLASHING
/ T.O. ROOF SCREEN
127'-9 1/2"
T.O COOLING TOWER
133'-8 5/8"
STACKS READING STACKS
CIRCULATION LOBBY BOOKSTORE
NEW FULLY ADHERED TPO MEMBRANE
OVERLAY OVER EXISTING MEMBRANE
RE: ROOF PLAN
NEW ROOF SCREEN
EXISTING COOLING TOWER BEYOND
NEW ROOF SCREEN FRAME
A3.1
EXISTING AIR HANDLING UNIT
NEW FULLY ADHERED TPO MEMBRANE
OVERLAY OVER EXISTING MEMBRANE
A5.2
A5.2
V.I.F
V.I.F
A5.2
A5.2POST FLASHING, RE: DETAIL
FINISH FLOOR
100'-0"
1091 2 3 4 5 6 7 8.685.82.91.6
T.O. MASONRY (HIGH)
130'-0" T.O. CONTROL ROOM FLASHING
/ T.O. ROOF SCREEN
127'-9 1/2"
T.O COOLING TOWER
133'-8 5/8"
A3.1
NEW FULLY ADHERED TPO MEMBRANE
OVERLAY OVER EXISTING MEMBRANE
NEW ROOF SCREEN
EXISTING COOLING TOWER BEYOND
NEW ROOF SCREEN FRAME
EXISTING AIR HANDLING UNIT
AUDITORIUM
CONTROL ROOM
PUBLIC MEETING CHILDREN'S ACTIVITY CENTER KITCHEN SNACK BAR CIRCULATION BOILER ROOM GARAGE
NEW POWDER COATED STEEL LADDER
NEW FULLY ADHERED TPO MEMBRANE
OVERLAY OVER EXISTING MEMBRANE
RE: ROOF PLAN
A5.2 10 A5.1
A5.2
A5.2
V.I.F
V.I.F
A5.2
POST FLASHING, RE: DETAIL
TE
L:
1.5
L
AK
E C
ITY
W
ES
T P
IE
RP
ON
T
A
VE
SH
EE
T N
O.
DA
TE
DR
AW
N
BY
PR
OJ
EC
T N
O.
TH
ES
E D
O C
U M
EN
TS
A R
E
IN
ST
R U
M
EN
TS
O
F S
ER
VI
L R
EM
AI
N T
H E
PR
O
PE
R
TY
O
F T
H E
AR
C
H
IT
EC
T.
N O
U
SE
O R
R E-
U
SE
O F
TH
ES
E D
O C
U M
L
BE
P
ER
M
IT
TE
D U
N
O R
IZ
ED
IN
W
R
IT
IN
G
B Y
PR
ES
C O
TT
M
U
IR
A R
C H
IT
EC
T W
IT
H
A
PP
R O
PR
IA
TE
C
O M
O
N . C
O
PY
R
IG
H T
PR
ES
CO
TT
M
UI
R
A
SS
OC
IA
TE
S, A P
RO
FE
SS
IO
NA
L C
OR
PO
RA
TIO
N
R O O F O
VE
R
LA
Y
BU
IL
DI
NG
S
EC
TI
ON
S
A 3.
AH
.09 .26
.00
W
EB
ER
C O U N
TY
L
IB
R A R Y
S A D A M S A
VE
W A
SH
IN
G
TO
N T
ER
R A C E, U T
PL
EA
SA
N T
VA
LL
EY
B R A N C H
SCALE 1/8" = 1'-0"1
SCALE 1/8" = 1'-0"2
1/2" DIAM.
EXPANSION BOLT
EXIST. EXTERIOR CMU
WALL
NEW GROUT SOLID @ EA.
CELL W/ NEW ANCHOR
NEW 3/8" x 4" BENT
PLATE WELDED TO
RAILS @ 48" O.C.
MAX.
3/4" DIAM. RUNGS @ 12" O.C.
2 1/2" X 3/4"
RAIL CONTINUOUS
A PLAN
B ELEVATION
A
C L C L
TY
P.
1'- 0"
LINE OF ROOF
MEMBRANE
9"
1/2" DIAM.
EXPANSION BOLT,
ATTACH TO EXIST.
CMU WALL
BEYOND, TYP.
3'- 6"
A5.1
C L C L
" M
AX
E.
Q.
S
PA
CE
NOTES:
RE: EXTERIOR/ELEVATIONS FOR LADDER, SIZE & PLACEMENT
LADDER TO COMPLY WITH OSHA STANDARDS
PROVIDE CONT. POWDER COATING
FIELD VERIFY DIMENSIONS
2.9 3
" M
IN
2'- 6"
1'-0"
GROUT SOLID @ EA. CELL WITH NEW ANCHOR
CL
MIN.
7"
EXIST. RIGID
INSULATION
NEW FULLY ADHERED TPO
MEMBRANE OVERLAY, RE:
ROOF PLANA5.1
A5.1
3 SIM
3/8" x 4" BENT PLATE WELDED TO RAILS
@ 48" O.C. MAX.
A5.1 1A
WALK-OFF TPO MATT @
T.O. COPING BETWEEN
LADDER EXTENSIONS
SIM
1/2" DIAM.
EXPANSION BOLT
3/4" DIAM. RUNGS @ 12" O.C.
2 1/2" X 3/4"
RAIL CONTINUOUS
NEW FULLY ADHERED TPO
MEMBRANE OVERLAY, RE:
ROOF PLAN
EXIST. TAPERED FIRE TREATED 2X PLATE
EXIST. MASONRY AS OCCURS, RE: ELEVATIONS
REMOVE AND REINSTALL CONTINUOUS
16 GA. STAINLESS STEEL CLEAT, ANCHOR
TO BLOCKING SCREWS @ 12" O.C.
REMOVE AND REPLACE CONT. SEALANT
EXISTING FULLY ADHERED SINGLE PLY
MEMBRANE ROOFING
3 1 /4"
1/4
1/2"
T.O MASONRY
REMOVE AND REINSTALL 0.063 CLEAR ANODIZED
ALUMINUM SHEET METAL COPING
NEW FULLY ADHERED TPO
MEMBRANE OVERLAY, RE: ROOF PLAN
REMOVE AND REPLACE GALV. FASTENER
EXIST. FLEXIBLE SHEET
MEMBRANE
EXIST. RIGID
INSULATION
EXIST. FLEXIBLE SHEET
MEMBRANE COUNTER
FLASHING
REMOVE AND REINSTALL
TERMINATION BAR
EXIST. MASONRY
NEW FULLY ADHERED TPO
MEMBRANE OVERLAY, EXTEND
UP WALL AND BEHIND REGLET
FLASHING, RE: ROOF PLAN
REMOVE AND REINSTALL EXIST.
SCREW ANCHOR W/ STEEL
BACKED NEOPRENE WASHER
OVER SURFACE MOUNTED
REGLET, PROVIDE NEW SEALANT
REMOVE AND REPLACE CONT.
SEALANT
REMOVE AND INSTALL FLASHING
REMOVE AND REINSTALL 0.063"
CLEAR ANODIZED ALUMINUM
SHEET METAL COPING
EXISTING 0.O63" CLEAR ANODIZED
ALUMINUM SHEET METAL PANELING
EXIST. WEATHER BARRIER
EXIST. 5/8" F.T. PLY WD. SHEATHING
EXIST. METAL STUD FRAMING W/
FULL BATT INSULATION
EXIST. 16 GA CONTINUOUS
STAINLESS STEEL CLEAT
EXIST. GALV. FASTENER
REMOVE AND REINSTALL EXIST. 16 GA
CONTINUOUS STAINLESS STEEL CLEAT
REMOVE AND REPLACE GALV.
FASTENER
EXIST. FLEXIBLE SHEET MEMBRANE
FLASHING
EXIST. 5/8" F.T. PLY WD. SHEATHING
REMOVE AND REPLACE EXIST.
SCREW ANCHOR @ 16" O.C. W/ STEEL
BACKENED NEOPRENE WASHERS TO
MEET FM I90
1/2"
REMOVE AND REPLACE
CONT. SEALANT
NEW FULLY ADHERED TPO MEMBRANE
OVERLAY RUN UP PARAPET WALL AND
UNDER COPING, RE: ROOF PLAN
EXISTING .O63" CLEAR ANODIZED
ALUMINUM STANDING SEAM SHEET METAL
PANELING ON CMU/ 5/8" F.T. PLY WD.
SHEATHING & METAL STUD FRAMING
REMOVE AND REINSTALL
EXISTING .O63" CLEAR ANODIZED
ALUMINUM SHEET METAL COPING
EXIST. FLEXIBLE SHEET MEMBRANE
FLASHING
REMOVE AND REINSTALL
EXISTING 16 GUAGE STAINLESS
STEEL CONTINOUS CLEAT
REMOVE AND REPLACE EXIST.
SCREW ANCHOR @ 16" O.C. W/
STEEL BACKED NEOPRENE
WAHSER TO MEET FM I90
3"3 1 /4"
1"
A5.1
3 SIM
NEW FULLY ADHERED TPO MEMBRANE
OVERLAY, RUN UP PARAPET WALL AND
UNDER COPING, RE: ROOF PLAN
REMOVE AND REPLACE EXIST.
SCREW ANCHOR
SIM
REMOVE AND REPLACE SCREW
ANCHOR @ 16" O.C. W/ STEEL BACKED
NEOPRENE WASHERS TO MEET FM I90
EXIST. FULLY ADHERED SINGLE PLY
ROOFING MEMBRANE
EXIST. GROUT SOLID
REMOVE AND REINSTALL EXISTING .063"
CLEAR ANODIZED ALUMINUM SHEET
METAL CAP FLASHING W/ FOLDED FLAT
SEAMS
EXIST. 4" ATLAS BRICK/8"
CMU, RE: ELEVATIONS
T.O. PARAPET
T.O. MASONRY
VARIES
3"
NEW FULLY ADHERED TPO
MEMBRANE OVERLAY, RUN UP
PARAPET WALL & UNDERCOPING
RE: ROOF PLAN
REMOVE AND REPLACE CONT. SEALANT
JOINT
EXIST. FULLY ADHERED SINGLE PLY
ROOFING MEMBRANE EXTEND OVER TOP OF
PARAPET
REMOVE AND REINSTALL EXISTING 0.063"
CLEAR ANODIZED ALUMINUM SHEET METAL
CAP FLASHING W/ FOLDED FLAT SEAMS
EXIST. 4" ATLAS
BRICK/8" CMU, RE:
ELEVATIONS
T.O. PARAPET
T.O. MASONRY
VARIES
NEW FULLY ADHERED TPO MEMBRANE
OVERLAY, RE: ROOF PLAN
REMOVE AND REPLACE
CONT. SEALANT
NEW CONT. MEMBRANE STRIP FLASHING
EXIST. STEEL STRUCTURE
EXIST. CONTINUOUS BENT STEEL PLATE
EXIST. 0.063" PRE-FINISHED PAINTED SHEET
METAL FASCIA, W/ FLAT FOLDED SEAMS ON
VERTICAL SURFACE AND STANDING SEAMS @
10'-0" O.C. ON HORIZONTAL SURFACE AND
CONTINUOUS HOLD DOWN AT EDGE
EXIST. PRE-FINISHED PAINTED SHEET METAL
SOFFIT PANELING
EXIST. 0.063" PRE-MANUFACTURED PAINTED SHEET
METAL PANELING
EXIST. CONTINUOUS BENT STEEL PLATE
EXIST. FLEXIBLE SHEET MEMBRANE
ROOFING ON RIGID INSULATION
ON METAL DECK
EXIST. PAINTED METAL DECKING
COLUMN
5.8
CL
DECK BEARING
VARIES
NEW CONTINUOUS STRIP FLASHING,
REMOVE EXISTING STRIP FLASHING
NEW FULLY ADHERED TPO MEMBRANE
OVERLAY, RE: ROOF PLAN
1/2"
5.8
STEEL STRUCTURE
EXIST. FLEXIBLE SHEET
MEMBRANE ON RIGID INSULATION
ON METAL DECK
EXIST. MEMBRANE UP 8"
BEHIND SHEET METAL
PANELING
EXISTING 0.063" CLEAR
ANODIZED ALUM. SHEET
METAL PANELING ON
WEATHER BARRIER ON F.T.
PLY WD. SHEATHING & METAL
STUD FRAMING
EXIST. STEEL STRUCTURE
5.8
T.O. MASONRY
112'-8"
B.O. VALANCE
112'-11 1/4"
NEW FULLY ADHERED TPO
MEMBRANE OVERLAY EXTEND UP
WALL & UNDER SHEET METAL
CLADDING, RE: ROOF PLAN
EXISTING FULLY ADHERED
FLEXIBLE SHEET MEMBRANE OVER
5/8" F.T. PLYWOOD SHEATHING
EXISTING FLEXIBLE SHEET
MEMBRANE OVER RIGID
INSULATION ON METAL DECK
EXIST. STEEL STRUCTURE
EXIST. STEEL BLOCKING
EXIST. PAINTED 5/8" GYP. BD. OVER
5/8" F.T. PLYWOOD SHEATHING ON
16 GA. 8" METAL STUD FRAMING @
16" O.C. W/ FULL BATT INSULATION
EXIST. STEEL STRUCTURE
EXIST. STEEL BLOCKING RE:
STRUCTURAL
EXIST. FLEXIBLE SHEET MEMBRANE
OVER RIGID INSULATION ON METAL
DECK RE: ROOF PLAN, EXTEND
MEMBRANE ROOFING UP GLASS
MATTE FACED GYP. BD. TO BEHIND
MASONRY REGLET
EXIST. 4" CMU VENEER OVER 5/8" GLASS MATTE
FACED GYPSUM SHEATHING
EXIST. STEEL LEDGER ANGLE,
RE: STRUCTURAL
EXIST. CAVITY DRAINAGE MESH
REMOVE AND REINSTALL
EXIST. MASONRY REGLET
OVER NEW FULLY ADHERED
TPO MEMBRANE OVERLAY
EXIST. THROUGH WALL
FLASHING
EXIST. WEEP TUBE
REMOVE AND REINSTALL EXIST. PRE-FINISHED
SHEET METAL COPING OVER F.T. 2x BLOCKING
T.O MASONRY
122'-8"
T.O. FLASHING
122'-11 1/4"
B.O. MASONRY
VARIES, RE: EXTERIOR ELEVATIONS
NEW FULLY ADHERED TPO
MEMBRANE OVERLAY, RUN
MEMBRANE UP PARAPET WALL &
UNDER COPING RE: ROOF PLAN
NEW FULLY ADHERED TPO
MEMBRANE OVERLAY, RE: ROOF
PLAN
A5.1
3 SIM
EXIST. PRE-FINISHED PAINTED
SHEET METAL PANELING OVER CMU
BLOCKING
EXIST. PAINTED METAL
DECKING
EXIST. 1" F.T. PLYWOOD SHEATHING
OVER F.T. WOOD BLOCKING
EXIST. 0.063" PRE-FINISHED
PAINTED SHEET METAL
COPING
EXIST. FULLY ADHERED
MEMBRANE ROOFING OVER
RIGID INSULATION ON METAL
DECKING
EXIST. STEEL STRUCTURE
BEYOND
EXIST. STEEL STRUCTURE
DECK BEARING @ GRID 'G'
118' - 0"
G A5.1
7 NEW FULLY ADHERED TPO
MEMBRANE OVERLAY, RE: ROOF
PLAN
NEW CONTINUOUS STRIP
FLASHING, REMOVE EXISTING
STRIP FLASHING
SIM
EXIST. SINGLE-PLY ROOF MEMBRANE OVER
RIGID INSULATION ON METAL DECK
EXIST. 0.040" ALUMINUM SHEET
METAL HEMMED OVER STEEL ANGLE
EXIST. CURTAIN WALL WINDOW HEAD
EXIST. STEEL BENT PLATE
EXIST. STEEL STRUCTURE
6"
1/2"
NEW FULLY ADHERED TPO MEMBRANE
OVERLAY, RE: ROOF PLAN
NEW CONTINUOUS STRIP FLASHING,
REMOVE EXISTING STRIP FLASHING
EXISTING FLEXIBLE SHEET MEMBRANE
ROOFING ON RIGID INSULATION ON
METAL DECK
EXISTING STEEL
STRUCTURE BEYOND
EXISTING PRE- MANUFACTURED PAINTED
SHEET METAL SOFFIT PANELING
EXISTING 0.063" PRE-FINISHED PAINTED
SHEET METAL FASCIA,
H
DECK BEARING @ GRID 'H'
116'-9"
EXISTING 0.063" PRE-MANUFACTURED
PAINTED SHEET METAL PANELING
EXISTING STEEL BENT PLATE
NEW FULLY ADHERED TPO MEMBRANE
OVERLAY, EXTEND UNDER EXISTING
SHEET METAL FLASHING RE: ROOF
PLAN NEW CONTINUOUS STRIP FLASHING; REMOVE
EXISTING STRIP FLASHING
1/2"
TE
L:
1.5
L
AK
E C
ITY
W
ES
T P
IE
RP
ON
T
A
VE
SH
EE
T N
O.
DA
TE
DR
AW
N
BY
PR
OJ
EC
T N
O.
TH
ES
E D
O C
U M
EN
TS
A R
E
IN
ST
R U
M
EN
TS
O
F S
ER
VI
L R
EM
AI
N T
H E
PR
O
PE
R
TY
O
F T
H E
AR
C
H
IT
EC
T.
N O
U
SE
O R
R E-
U
SE
O F
TH
ES
E D
O C
U M
L
BE
P
ER
M
IT
TE
D U
N
O R
IZ
ED
IN
W
R
IT
IN
G
B Y
PR
ES
C O
TT
M
U
IR
A R
C H
IT
EC
T W
IT
H
A
PP
R O
PR
IA
TE
C
O M
O
N . C
O
PY
R
IG
H T
PR
ES
CO
TT
M
UI
R
A
SS
OC
IA
TE
S, A P
RO
FE
SS
IO
NA
L C
OR
PO
RA
TIO
N
R O O F O
VE
R
LA
Y
DE
TA
IL
S
A 5.
AH
.09 .26
.00
W
EB
ER
C O U N
TY
L
IB
R A R Y
S A D A M S A
VE
W A
SH
IN
G
TO
N T
ER
R A C E, U T
PL
EA
SA
N T
VA
LL
EY
B R A N C H
VARIES
1/2" = 1'-0" 1STEEL LADDER
VERTICAL
1" = 1'-0" 6LADDER TO ROOF DETAIL
VERTICAL
12" = 1'-0" 3COPING DETAIL
VERTICAL
3" = 1'-0" 11TYP. COUNTERFLASHING DETAIL @ MASONRY
VERTICAL
3" = 1'-0" 7TYP. COPING DETAIL @ SHEET METAL VERTICAL
3" = 1'-0" 5TYP. COPING DETAIL
VERTICAL
3" = 1'-0" 9PARAPET DETAILVERTICAL
3" = 1'-0" 10MASONRY COPING DETAIL
VERTICAL
1 1/2" = 1'-0" 13ROOF DETAILVERTICAL
1 1/2" = 1'-0" 15ROOF DETAIL
VERTICAL
1" = 1'-0" 8ROOF TRANSITION TO MASONRY
VERTICAL
1 1/2" = 1'-0" 12SLOPING ROOF DETAIL
VERTICAL
3" = 1'-0" 16WINDOW HEAD VERTICAL
1 1/2" = 1'-0" 14ROOF EDGE DETAIL @ MASONRY
COLUMN
EXISTING ROOF MEMBRANE
EXISTING 0.063" PRE-FINISHED PAINTED SHEET METAL FASCIA,
W/ FLAT FOLDED SEAMS ON VERTICAL SURFACE AND
STANDING SEAMS @ 10'-0" O.C. ON HORIZONTAL SURFACE AND
CONTINUOUS HOLD DOWN AT EDGE
EXISTING STEEL
STRUCTURE
EXISTING PRE-MANUFACTURED PAINTED SHEET METAL SOFFIT
PANELING
DECK BEARING
VARIES, RE: ROOF PLAN
A.1
CL
A
EXISTING ROOF
MEMBRANE OVER
RIGID INSULATION ON
1/4" DENS DECK ON
METAL DECKING, RE:
ROOF PLAN
NEW FULLY ADHERED
TPO MEMBRANE
OVERLAY, RE: ROOF
PLAN
EXISTING STEEL BENT PLATE
NEW CONTINUOUS STRIP FLASHING, REMOVE EXISTING STRIP
FLASHING
SLOPE
1.71 RE: ROOF PLAN
1/2"
EXISTING CANTILEVERED STEEL
STRUCTURE BEYOND
LINE OF FACE OF VESTIBULE
STOREFRONT BELOW
SLOPE 1/4":12"
EXISTING STEEL STRUCTURE
EXISTING 0.063" PRE-FINISHED PAINTED SHEET METAL FASCIA,
W/ FLAT FOLDED SEAMS ON VERTICAL SURFACE AND
STANDING SEAMS @ 10'-0" O.C. ON HORIZONTAL
SURFACE AND CONTINUOUS HOLD DOWN AT EDGE
SLOPE 1/4":12"
DECK BEARING / B.O. STEEL PLATE
116'-7"
EXISTING STEEL BENT PLATE
EXISTING STEEL STRUCTURE
EXISTING ROOF MEMBRANE ON TAPERED RIGID
INSULATION ON METAL DECK, RE: ROOF PLAN
LINE OF METAL FLASHING BEYOND
NEW FULLY ADHERED TPO MEMBRANE OVERLAY,
RE: ROOF PLAN
NEW CONTINUOUS STRIP FLASHING, REMOVE EXISTING STRIP
FLASHING 1/2"
EXISTING STEEL
STRUCTURE BEYOND
EXISTING MEMBRANE
ROOFING OVER RIGID
INSULATION ON METAL
DECK, EXTEND OVER
CANT STRIP AND
PERIMETER BLOCKING
EXISTING 0.063" PRE-FINISHED PAINTED SHEET
METAL FASCIA, W/ FLAT FOLDED SEAMS ON
VERTICAL SURFACE AND STANDING SEAMS @ 10'-0"
O.C. ON HORIZONTAL SURFACE AND CONTINUOUS
HOLD DOWN AT EDGE
EXISTING PRE-MANUFACTURED PAINTED SHEET
METAL SOFFIT PANELING OVER WEATHER BARRIER
ON 5/8" F.T. PLYWOOD SHEATHING ON 3 5/8" 20 GA.
STUD FRAMING @ 16" O.C.
EXISTING MEMBRANE ROOFING OVER 1/2" F.T.
PLYWOOD SHEATHING
EXISTING STEEL BENT PLATE
EXISTING STEEL STRUCTURE
NEW FULLY ADHERED TPO
MEMBRANE OVERLAY, RE:
ROOF PLAN
NEW FULLY ADHERED TPO MEMBRANE OVERLAY,
RE: ROOF PLAN
EXISTING EXTERIOR MASONRY,
RE: EXTERIOR ELEVATIONS
1/2"
NEW CONTINUOUS STRIP FLASHING, REMOVE
EXISTING STRIP FLASHING
SLOPE 1/2"
EXISTING MEMBRANE ROOFING
EXISTING PRE-FINISHED PAINTED
SHEET METAL FLASHING, W/
CONTINUOUS 16 GA. STAINLESS STEEL
HOLD DOWN CLEAT FASTENED TO 5/8"
F.T. PLYWOOD, TYP.
EXISTING MEMBRANE ROOFING OVER
RIGID INSULATION ON 4" LIGHTWEIGHT
CONCRETE AND METAL DECK
EXISTING FULLY ADHERED SINGLE-PLY
ROOFING MEMBRANE ON 5/8" FIRE
TREATED PLYWOOD SHEATHING FULLY
ADHERED TO STEEL BENT, EXTEND
PLYWOOD AND MEMBRANE OVER TOP
OF BENT PLATE
T.O. CORNICE
130'-8"
T.O. MASONRY
130'-0"
DECK BEARING @ MASONRY
127'-4 1/8"
NEW FULLY ADHERED TPO MEMBRANE
OVERLAY, RE: ROOF PLAN
NEW FULLY ADHERED TPO MEMBRANE
OVERLAY, EXTEND UP PARAPET &
OVER BENT PLATE TO COPING RE:
ROOF PLAN
EXISTING ROCK BALLAST, 1/3 OF BALLAST
TO BE PLACED EVENLY OVER EXISTING
ADJACENT ROOF AT A TIME TO AVOID
OVERLOADING THE EXISTING ROOF
STRUCTURE
NEW FULLY ADHERED TPO MEMBRANE
OVERLAY, RE: ROOF PLAN
EXISTING STEEL BENT PLATE
KNIFE EDGE
NEW CONTINUOUS STRIP FLASHING,
REMOVE EXISTING
EXISTING STEEL BENT PLATE
1 3/8" 1/2"
EXISTING BEAM / NEW COLUMN POSTCL
EXISTING STEEL BEAM
EXISTING METAL DECK
ATTACH NEW BASE SUPPORT
TO TOP FLANGE OF EXISTING
STEEL BEAM WITH TEK
SCREWS PER ROOF SCREEN
MFR. CALCULATIONS, TYP.,
RE: ROOF SCREEN
MANUFACTURER
MIN. FLANGE WIDTH
VARIES, V.I.F
V.
I.F
IN
SU
LA
TIO
N
DE
PT
H
VA
RI
ES
BASE SUPPORT EXTENSION
AS REQUIRED, RE: ROOF
SCREEN MANUFACTURER
FLASHING, RE: ROOF
SCREEN MANUFACTURER
EXISTING ROOF MEMBRANE
OVER RIGID INSULATION
NEW FULLY ADHERED TPO ROOF
MEMBRANE OVERLAY, RE: ROOF
PLAN
BASE GASKET, BY ROOF
SCREEN MANUFACTURER
BASE CAP ASSEMBLY, BY
ROOF SCREEN
MANUFACTURER
ROOF SCREEN HORIZONTAL
FRAME
ROOF SCREEN FRAME
BRACKET BEYOND
VE
RI
FY
W
/ R
OO
FIN
G
RO
OF
S
CR
EE
N
VE
ND
OR
8" M
IN
PAINT TO MATCH ADJACENT
AT ALL EXPOSED TO VIEW
EXIST. PRE-MANUFACTURED PAINTED
SHEET METAL SOFFIT PANELING OVER
WEATHER BARRIER ON 5/8" F.T. PLYWOOD
SHEATHING ON STUD FRAMING
EXIST. STEEL STRUCTURE
EXIST. STEEL BENT PLATE
EXIST. 0.063" PREFINISHED PAINTED
SHEET METAL FASCIA W/ FLAT FOLDED
SEAMS ON VERTICAL SURFACE AND
STANDING SEAMS @ 10" O.C. ON
HORIZONTAL SURFACE AND CONTINUOUS
STAINLESS STEEL HOLD DOWN AT EDGE
EXIST. PREFINISHED PAINTED SHEET
METAL FASCIA RETURN BEYOND
EXIST. FULLY
ADHERED MEMBRANE
ROOFING OVER RIGID
INSULATION
ON METAL DECKING
EXIST. PREFINISHED PAINTED SHEET
METAL PANELING BEYOND
G
NEW FULLY ADHERED
TPO MEMBRANE
OVERLAY, RE: ROOF
PLAN
1/2"
NEW CONTINUOUS STRIP FLASHING,
REMOVE EXISTING STRIP FLASHING
EXIST. STEEL
STRUCTURE
EXIST. MEMBRANE ROOFING
OVER RIGID INSULATION ON
METAL DECK
EXIST. PRE-MANUFACTURED PAINTED
SHEET METAL SOFFIT PANELING OVER
WEATHER BARRIER ON 1" F.T. PLYWOOD
SHEATHING ON 1 5/8" 20 GA. STUD
FRAMING @ 16" O.C.
EXIST. STEEL BENT PLATE
EXIST. 0.063" PRE-FINISHED PAINTED SHEET
METAL FASCIA, W/ FLAT FOLDED SEAMS ON
VERTICAL SURFACE AND STANDING SEAMS @
10'-0" O.C. ON HORIZONTAL SURFACE AND
CONTINUOUS HOLD DOWN AT EDGEEXIST. STEEL STRUCTURE BEYOND
SLOPE
J
1/2"
NEW FULLY ADHERED TPO
MEMBRANE OVERLAY, RE:
ROOF PLAN
NEW CONTINUOUS STRIP
FLASHING, REMOVE
EXISTING STRIP FLASHING
PLUMBING VENT, PIPE
PENETRATION OR GAS PIPING
1'- 0"
M
IN
ROOFING SEALANT
DRAWBAND ATTACHMENT WITH FULL
SEALANT BETWEEN PIPE & PRE-FABRICATED
MEMBRANE FLASHING BOOT
SEALED SEAM WITH SEAM CAULK PER
MANUFACTURERS STANDARD DETAIL
PRE-FABRICATED MEMBRANE
FLASHING BOOT
NOTE:
IMPLEMENT MANUFACTURER'S RECOMMENDED PIPE
FLASHING DETAILS WHERE PRE-FABRICATED MEMBRANE
BOOT FLASHING IS NOT COMPATIBLE WITH PIPE DIAMETER
ROOF ASSEMBLY, RE: STRUCTURAL
CONT. "J" TRIM TO MATCH PANEL
NOTE: VERIFY ATTACHMENTS &
CONFIGURATION W/ ROOF SCREEN MFR.
CONT. HORIZONTAL HAT CHANNEL
GIRT BY ROOF SCREEN VENDOR.
CONT. 16 GAUGE SS 4" X4" ANGLE
CONT. "J" TRIM TO MATCH PANEL
SMOOTH, FLUSH PROFILE PANEL,
RE: EXIST. ELEVATIONS
SMOOTH, FLUSH PROFILE PANEL,
RE: EXIST. ELEVATIONS
TE
L:
1.5
L
AK
E C
ITY
W
ES
T P
IE
RP
ON
T
A
VE
SH
EE
T N
O.
DA
TE
DR
AW
N
BY
PR
OJ
EC
T N
O.
TH
ES
E D
O C
U M
EN
TS
A R
E
IN
ST
R U
M
EN
TS
O
F S
ER
VI
L R
EM
AI
N T
H E
PR
O
PE
R
TY
O
F T
H E
AR
C
H
IT
EC
T.
N O
U
SE
O R
R E-
U
SE
O F
TH
ES
E D
O C
U M
L
BE
P
ER
M
IT
TE
D U
N
O R
IZ
ED
IN
W
R
IT
IN
G
B Y
PR
ES
C O
TT
M
U
IR
A R
C H
IT
EC
T W
IT
H
A
PP
R O
PR
IA
TE
C
O M
O
N . C
O
PY
R
IG
H T
PR
ES
CO
TT
M
UI
R
A
SS
OC
IA
TE
S, A P
RO
FE
SS
IO
NA
L C
OR
PO
RA
TIO
N
R O O F O
VE
R
LA
Y
DE
TA
IL
S
A 5.
NM
.09 .26
.00
W
EB
ER
C O U N
TY
L
IB
R A R Y
S A D A M S A
VE
W A
SH
IN
G
TO
N T
ER
R A C E, U T
PL
EA
SA
N T
VA
LL
EY
B R A N C H
VERTICAL
1 1/2" = 1'-0" 1EAST CANOPY @ GLAZINGVERTICAL
1 1/2" = 1'-0" 3CANOPY @ NORTH ENTRY
VERTICAL
1 1/2" = 1'-0" 7SOUTH CANOPY @ MASONRY WALL
VERTICAL
1 1/2" = 1'-0" 10AUDITORIUM CAP DETAIL VERTICAL
3" = 1'-0" 9ROOF SCREEN POST ATTACHMENT DETAILVERTICAL
1 1/2" = 1'-0" 11ROOF DETAIL @ KNIFE EDGEVERTICAL
1 1/2" = 1'-0" 12ROOF CANOPY DETAIL
VERTICAL
1 1/2" = 1'-0" 13TYPICAL FLASHING @ ROOF PENETRATIONHORIZONTAL
3" = 1'-0" 14ROOF SCREEN CORNER & END DETAIL
| T1 - TITLE SHEET |
| A1.3 - ROOF PLAN |
| A2.1 - EXTERIOR ELEVATIONS |
| A3.1 - BUILDING SECTIONS |
| A5.1 - DETAILS |
| A5.2 - DETAILS |
File details come from the government source that posted it. Updated .