2-2-DA27004-26327480 Approved Plans.pdf
PDF 9 MB Posted
- Solicitation number
- DA27004
- Issued by
- Utah
About this file
This is an Approved Plans document for the Utah Division of Facilities Construction and Management (DFCM) related to construction project #26327480 at Camp Williams. The project involves the removal and replacement of existing roof-top units (RTUs), updated controls installation, and new architectural finishes for Building 6150. This is an invitational bidding opportunity limited to six pre-selected contractors: Halverson Mechanical, Innovative Sheet Metal, Mechanical Service & Systems, Rocky Mountain Mechanical, Salmon Mechanical, and Tod Packer Heating and Air. A mandatory meeting is required for all invited bidders to attend before submitting proposals.
The construction cost estimate for this HVAC and RTU upgrade project is $80,000.00. The approved plans document serves as the technical specification and design reference for bidders to prepare their proposals and cost estimates. All invited contractors must utilize these approved plans when developing their bid responses for the Utah National Guard facility upgrade.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
North: ______ South: ______ East: ______ West: ______
Special Use and Occupancy (e.g. High Rise, Covered Mall): __________________
d) Unlimited Area Building: Yes ______ No ______ Code Section: ______ a a
3) Three Story: A (3)______
2) Two Story: A (2)______
1) One Story: ______
c) Total Allowable Area for:
1_< Allowable Area
Actual Area
b) Sum of the Ratio Calculations for Mixed Occupancies:
a) 0.25I = 100f
F
P 30
WstA I
100100 fIA t taA = A + +
Official for Complex Buildings. Including, but not limited to:
g) Fire Stopping, Including Tested Design Number.
f) Exterior and Interior Accessibility Route.
e) Fire Assembly Locator Sheet.
a) High Rise Requirements.
b) Atriums.
c) Performance Based Criteria.
d) Means or Egress Analysis.
2) Additional Code Information shall be provided at the discretion of the Building
Code Accessibility Chapters, the more restrictive requirement shall govern.
through - ADA Guidelines and specific reference to the International Building
1) In case of conflict with the U.S. Department of Justice Federal Registers Parts
FOOTNOTES:
d) Drinking Fountains: ______ Service Sinks: ______
c) Bath Tubs or Showers: ______
b) Lavatories - Required (m) ______ (f) ______ Provided (m) ______ (f) ______
a) Water Closets - Required (m) ______ (f) ______ Provided (m) ______ (f) _____
M. Minimum Number of Required Plumbing Facilities:
Exit Width Required: ______ Exit Width Provided: ______
Element Hours Assembly ListingListing
Element AssemblyHours
Smoke Partitions
Fire Partitions
Exterior Bearing Walls
Interior Bearing Walls
Exterior Non-Bearing Walls
Structural Frame
Partitions - Permanent
Fire Barriers
Floors - Ceiling Floors
Roofs - Ceiling Roofs
Exterior Doors and Windows
Shaft Enclosures
Fire Walls
BAHTBABABA
Design Wind Speed: ______ mphB. Seismic Design Category: ______
L. Design Occupant Load: ______
K. Fire Resistance Rating Requirements for Building Elements (hours).
Area Modifications:J:
____________________________________________Tabular Area:I:
per Floor (square feet): __________________________Actual AreaH:
Number of Stories: ______ Building Height: ______G:
Required: ______ Provided: ______ Type of Sprinkler System: ____________
Sprinklers:F:
Mixed Occupancies: ______ Nonseparated Uses: ______E.
separation distance (in hours):
Requirements for the Exterior Walls based on the fireFire Resistance RatingD.
C. Type of Construction (circle one):
Change in Use: Yes ______ No ______ Mixed Occupancy: Yes ______ No ______
Guidelines
ADA Accessibility
Building Conservation
Uniform Code for
National Electrical Code
Conservation Code
International Energy
International Fire Code
International Plumbing Code
International Mechanical Code
International Building Code
YearYear
APPLICABLE CODES
A. Occupancy and Group: ________ ________ ________ ________ ________
CODE ANALYSIS
Risk Category: _II_ Wind Exposure __B:B1. Sds 0.7g Sd1 0.45g LFRS and R NA
IND
USTRY
UNG BUILDING 6150
RTU REPLACEMENT
DFCM# 26327480
PROJECT SCOPE:
THIS SHALL INCLUDE: THE REMOVAL AND REPLACEMENT OF 5
PACKAGED ROOFTOP UNITS. GAS, ELECTRICAL, AND
CONTROLS CONNECTIONS SHALL BE REPLACED AND UNITS
SHALL BE SELECTED TO MINIMIZE ROOFING WORK. ALL
UNITS SHALL BE PROVIDED WITH FACTORY START UP AND
TEST AND BALANCE.
ADD ALT 1: PROVIDE ROOF ACCESS FROM INTERIOR. NEW
HAND OPERATED ROOF HATCH WITH GUARD RAILS.
ADD ALT 2: PROVIDE WALL AND DOOR TO BIFURCATE THE
EXISTING BREAK ROOM AND PROVIDE NEW MECHANICAL
CONTROLS ROOM.
BAT INFO AND PROTECTION: A MATERNAL BAT COLONY AND
BAT BOX EQUIPMENT (SOLAR PANEL, ANTENNA, WIRING) ARE
LOCATED IN THE NORTH END OF BUILDING 6150 AND MUST
NOT BE DISTURBED. CONTRACTOR SHALL NOT HANDLE OR
ADJUST BAT EQUIPMENT; ANY REQUIRED WORK MUST BE
COORDINATED WITH THE POC. IF BATS ARE FOUND INSIDE
THE BUILDING OR OBSERVED ACTIVE DURING THE DAY, DO
NOT TOUCH AND CONTACT THE POC IMMEDIATELY. KILLING
OR HARMING BATS IS PROHIBITED UNDER UTAH STATE LAW. A
PRE-CONSTRUCTION BRIEFING WITH THE POC IS REQUIRED
TO REVIEW BAT PROTECTION PROCEDURES.
POC: CHRIS FRAUENHOFER, UTARNG WILDLIFE BIOLOGIST -
CHRIS.A.FRAUENHOFER.NFG@ARMY.MIL - (801) 878-5240
ALL THOSE WORKING ON SITE SHALL PASS AND COMPLETE A
REAL ID AND BACKGROUND CHECK.
CODE REVIEW STAMP
DESIGN CRITERIA:
THESE DOCUMENTS - DRAWINGS AND SPECIFICATIONS COMPLY WITH ALL
THE REQUIREMENTS OF THE DFCM STANDARDS FOR MECHANICAL
UPGRADES OF EXISTING BUILDING.
CODE INSPECTION REQUIREMENTS:
1. BEFORE A FINAL ACCEPTANCE CAN BE ISSUED, THE STATE APPOINTED
CODE INSPECTOR SHALL PROVIDE A FINAL REPORT RECOMMENDING THAT
THE NEW MECHANICAL WORK IS IN COMPLIANCE WITH THE DRAWINGS,
SPECIFICATIONS AND APPLICABLE CODES ESPECIALLY FOR THE
FOLLOWING ITEMS.
a.)SEISMIC - MECHANICAL AND ELECTRICAL PER DEFERRED SUBMITTALS.
2. SEE ALSO SHEET G002.
GENERAL:
G001- TITLE SHEET
G002- SPECIAL INSPECTIONS AND TESTING
G003 - NONSTRUCTURAL COMPONENT CHECKLIST
MECHANICAL:
MG001 - MECHANICAL GENERAL NOTES AND LEGEND
MD101 - MEZZANINE DEMOLITION PLAN
MD102 - ROOFTOP DEMOLITION PLAN
ME101 - MEZZANINE MECHANICAL PLAN
ME102 - ROOFTOP MECHANICAL PLAN
ME501 - MECHANICAL DETAILS AND SCHEDULES
ME502 - MECHANICAL DETAILS
DRAWING INDEX:
UTAH NATIONAL GUARD CAMP WILLIAMS
17800 1700 W, BLUFFDALE, UT 84065
B
X X
NA
D 115
0 0 0 0
NO YES
NO YES EXIST WET PIPE
2 32'-6"
X TABLE 503
EXIST EXIST
EXIST EXIST
6,809
204" 210"
T H E
G R E A T
S E
A L
OF THE
S
T A T E
O F
U T A H
State of Utah-Department of Government Operations
DIVISION OF FACILITIES CONSTRUCTION
AND MANAGEMENT
4315 South 2700 West, Floor 3/Taylorsville, Utah 84129-2128
S E
F O
R P
H
ATUFOETA
T S
R E
E
NI
GNELANOIS
JOHN M.
LARSEN
No. 12199025
02/25/2026
WORK AREA
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
REVIEWED FOR
CODE COMPLIANCE
THOMAS PETERSON
06/24/2026
JOHN M.
LARSEN
No. 12199025
P R
O
FE
SSIONAL ENG
IN
E
E R
S T
A T E O F
U T
A H
A
LL
ID
E
A S
, D E
S
IG
N S
A
R R
A N
G E
M E
N T
S A
N D
P
LA
N S
IN
D
IC
A
T E
D O
R R
E P
R E
S E
N T
E D
B Y
T H
IS
D
R A
W
IN
G A
R E
O W
N E
D B
Y A
N D
T H
E P
R O
P E
R T
Y O
F W
H W
E N
G
IN
E E
R
IN
G
IN
C . A
N D
W E
R E
C R
E A
T E
D , E
V O
LV
E
D , A
N D
D E
V E
LO
P
E D
F O
R U
S E
O N
A N
D
IN
C O
N N
E C
T
IO
N W
IT
H
T H
E S
P E
C
IF
IE
D
P R
O
JE
C T
N
O N
E O
F T
H E
ID
E
A S
D
E S
IG
N
S
A R
R A
N G
E M
E N
T S
O R
P
LA
N S
S H
A
LL
B E
U S
E D
B Y
O R
D
IS
C
LO
S E
D T
O A
N Y
P E
R S
O N
, F
IR
M
O R
C O
R P
O R
A T
IO
N
F O
R A
N Y
P U
R P
O S
E W
H A
T S
O E
V E
R W
IT
H
O U
T W
R
IT
T E
N C
O N
S E
N T
O F
W H
W E
N G
IN
E
E R
IN
G
IN
C
W
R
IT
T E
N D
IM
E
N S
IO
N
S O
N T
H E
S E
D R
A W
IN
G
S S
H A
LL
H
A V
E P
R E
C E
D E
N C
E O
V E
R S
C A
LE
D
IM
E
N S
IO
N
S
C O
N T
R A
C T
O R
S S
H A
LL
V
E R
IF
Y
A N
D B
E R
E S
P O
N S
IB
LE
F O
R A
LL
D
IM
E
N S
IO
N
S A
N D
C O
N D
IT
IO
N S
O N
T H
E J
O B
A N
D T
H
IS
O F
F
IC
E M
U S
T B
E N
O T
IF
IE
D O
F A
N Y
V A
R
IA
T
IO
N F
R O
M T
H E
D
IM
E N
S
IO
N S
A N
D C
O N
D
IT
IO
N
S S
H O
W N
B Y
T H
E S
E D
R A
W
IN
G S
W
A R
N
IN
G : R
E P
R O
D U
C T
IO
N
H E
R E
O F
IS
A
C R
IM
IN
A L
O F
F E
N S
E U
N D
E R
U .S
.C . S
E C
. 5
. U N
A U
T H
O R
IZ
E
D D
IS
C
LO
S
U R
E M
A Y
C O
N S
T
IT
U T
E T
R A
D E
S E
C R
E T
M
IS
A P
P R
O P
R
IA
T
IO
N
IN
V
IO
LA
T
IO
N
O F
I.
C
.2 4-
2-
-1 E
T . S
E Q
. A N
D O
T H
E R
L A
W S
CONSULTANTS
PROJECT NAME & ADDRESS
CODE REVIEW STAMP
SHEET NO.
PROJECT MANAGER:
DATE:
CHECKED BY:
DRAWN BY:
REVISIONDATEMARK
02/25/2026
WHW JOB NO.:
25117
A
B
C
D
1 2 3
1 2 3
A
B
C
D
SHEET TITLE
JL
JL
UTNG 6150
HVAC
UPGRADES
17800 1700 W, BLUFFDALE, UT 84065
DD
DFCM#26327480
02/25/2026
SPECIAL
INSPECTION AND
TESTING FORM
G002
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
REVIEWED FOR
CODE COMPLIANCE
JOHN M.
LARSEN
No. 12199025
P R
O
FE
SSIONAL ENG
IN
E
E R
S T
A T E O F
U T
A H
A
LL
ID
E
A S
, D E
S
IG
N S
A
R R
A N
G E
M E
N T
S A
N D
P
LA
N S
IN
D
IC
A
T E
D O
R R
E P
R E
S E
N T
E D
B Y
T H
IS
D
R A
W
IN
G A
R E
O W
N E
D B
Y A
N D
T H
E P
R O
P E
R T
Y O
F W
H W
E N
G
IN
E E
R
IN
G
IN
C . A
N D
W E
R E
C R
E A
T E
D , E
V O
LV
E
D , A
N D
D E
V E
LO
P
E D
F O
R U
S E
O N
A N
D
IN
C O
N N
E C
T
IO
N W
IT
H
T H
E S
P E
C
IF
IE
D
P R
O
JE
C T
N
O N
E O
F T
H E
ID
E
A S
D
E S
IG
N
S
A R
R A
N G
E M
E N
T S
O R
P
LA
N S
S H
A
LL
B E
U S
E D
B Y
O R
D
IS
C
LO
S E
D T
O A
N Y
P E
R S
O N
, F
IR
M
O R
C O
R P
O R
A T
IO
N
F O
R A
N Y
P U
R P
O S
E W
H A
T S
O E
V E
R W
IT
H
O U
T W
R
IT
T E
N C
O N
S E
N T
O F
W H
W E
N G
IN
E
E R
IN
G
IN
C
W
R
IT
T E
N D
IM
E
N S
IO
N
S O
N T
H E
S E
D R
A W
IN
G
S S
H A
LL
H
A V
E P
R E
C E
D E
N C
E O
V E
R S
C A
LE
D
IM
E
N S
IO
N
S
C O
N T
R A
C T
O R
S S
H A
LL
V
E R
IF
Y
A N
D B
E R
E S
P O
N S
IB
LE
F O
R A
LL
D
IM
E
N S
IO
N
S A
N D
C O
N D
IT
IO
N S
O N
T H
E J
O B
A N
D T
H
IS
O F
F
IC
E M
U S
T B
E N
O T
IF
IE
D O
F A
N Y
V A
R
IA
T
IO
N F
R O
M T
H E
D
IM
E N
S
IO
N S
A N
D C
O N
D
IT
IO
N
S S
H O
W N
B Y
T H
E S
E D
R A
W
IN
G S
W
A R
N
IN
G : R
E P
R O
D U
C T
IO
N
H E
R E
O F
IS
A
C R
IM
IN
A L
O F
F E
N S
E U
N D
E R
U .S
.C . S
E C
. 5
. U N
A U
T H
O R
IZ
E
D D
IS
C
LO
S
U R
E M
A Y
C O
N S
T
IT
U T
E T
R A
D E
S E
C R
E T
M
IS
A P
P R
O P
R
IA
T
IO
N
IN
V
IO
LA
T
IO
N
O F
I.
C
.2 4-
2-
-1 E
T . S
E Q
. A N
D O
T H
E R
L A
W S
CONSULTANTS
PROJECT NAME & ADDRESS
CODE REVIEW STAMP
SHEET NO.
PROJECT MANAGER:
DATE:
CHECKED BY:
DRAWN BY:
REVISIONDATEMARK
02/25/2026
WHW JOB NO.:
25117
A
B
C
D
1 2 3
1 2 3
A
B
C
D
SHEET TITLE
JL
JL
UTNG 6150
HVAC
UPGRADES
17800 1700 W, BLUFFDALE, UT 84065
DD
DFCM#26327480
02/25/2026
NONSTRUCTURAL
COMPONENT
CHECKLIST
G003
X SEISMIC BRACKET
SHOWN ON ME502
N/A
X N/A
X N/A
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
REVIEWED FOR
CODE COMPLIANCE
MECHANICAL LEGEND
SYMBOL ABR, DESCRIPTION
GENERAL TERMINOLOGY
A
ME101
SECTION LETTER DESIGNATION
SECTION DRAWN ON THIS SHEET
A2
AH
DETAIL NUMBER DESIGNATION
CORRESPONDING WITH GRID
LOCATION
MECHANICAL EQUIPMENT DESIGNATION
EQUIPMENT ITEM DESIGNATION
REGISTER, GRILLE OR DIFFUSER
DESIGNATION WITH BALANCING CFM
LISTED BELOW
D-1
CFM
GRILLE OR LOUVER DESIGNATION
WHERE BALANCING NOT REQUIREDR-1
REVISION DESIGNATOR AND NUMBER
KEY NOTE DESIGNATOR AND
NUMBER
POINT OF CONNECTION
POINT OF REMOVAL
ABOVE FINISHED FLOOR
ACCESS PANEL
CENTERLINE ELEVATION
GENERAL CONTRACTOR
AFF
AP
POC
POR
C EL.
GC
MECHANICAL CONTRACTORMC
CONTROLS CONTRACTORATC
ELECTRICAL CONTRACTOREC
FIRE PROTECTION CONTRACTORFPC
NOT IN CONTRACTNIC
NOT TO SCALENTS
VITRIFIED CLAY PIPEVCP
NORMALLY CLOSEDNC
COMMONC
NORMALLY OPENNO
SYMBOL ABR, DESCRIPTION
AIR SIDE
EXISTING AIR DUCT TO BE REMOVED
EXISTING AIR DUCT TO REMAIN
NEW AIR DUCT
RECT TO RECT AIR DUCT TAKE-OFF
RECT TO RND AIR DUCT TAKE-OFF
RND TO RND AIR DUCT TAKE-OFF
MEDIUM PRESSURE TAKE-OFF
FLEXIBLE AIR DUCT
LINED DUCT
RADIUS ELBOW
ECCENTRIC DUCT TRANSITION
CONCENTRIC DUCT TRANSITION
VOLUME DAMPER
SUPPLY AIR DIFFUSER
RETURN & TRANSFER AIR GRILLE
EXHAUST GRILLE OR CEILING EXH.
FAN
RETURN & OUTSIDE AIR DUCT UP/DN
RETURN & OA ROUND DUCT UP/DN
SUPPLY AIR DUCT UP/DN
SUPPLY AIR ROUND DUCT UP/DN
EXHAUST AIR DUCT UP/DN
EXHAUST AIR ROUND DUCT UP/DN
ACCESS PANELAP
EXISTING EQUIPMENT TO BE REMOVED
EXISTING EQUIPMENT TO REMAIN
NEW EQUIPMENT
SUPPLY AIR
RETURN AIRRA
SA
EXHAUST AIREA
OUTSIDE AIROA
MIXED AIRMA
RELIEF AIRRF
FLAT OVALFO
MOTORIZED VOLUME DAMPER
BACKDRAFT DAMPER
FIRE DAMPER
SMOKE DAMPER
FIRE & SMOKE DAMPER
WALL MOUNTED THERMOSTAT
WALL MOUNTED TEMP. SENSOR
WALL MOUNTED HUMIDISTAT
WALL MOUNTED FIRESTAT
M
BD
F
S
FS
T
S
H
F
MVD
BD
FD
SD
FS
T-STAT
H-STAT
F-STAT
PLUMBING LEGEND
MEANING
SYMBOL OR
ABBREVIATION
MEANING
SYMBOL OR
ABBREVIATION
HOT WATER LINE WALL CLEANOUT WCO
COLD WATER LINE CLEANOUT CO
HOT WATER
RECIRCULATING LINE
CLEANOUT TO GRADE COTG
VENT LINE FLOOR CLEANOUT FCO
WASTE LINE BALL VALVE
GAS LINE UNION
VENT THRU ROOF VTR
CONNECTION TO
EXISTING PIPING
UNDER FLOOR UF REGULATOR
SANITARY SEWER SOFT WATER SW
PRIMARY ROOF DRAIN SECONDARY ROOF DRAIN
R
SS
G
SRDPRD
SS
V
HWREC
CW
HW
FIXTURE CALLOUT FIXTURE CALLOUT ABOVE WCWC-1
GENERAL NOTES
G-1 - MECHANICAL INFORMATION IS NOT LIMITED TO THE MECHANICAL DRAWINGS.
CONTRACTOR SHALL BE RESPONSIBLE FOR INFORMATION OF THE EXISTING BUILDING AND SITE
CONDITIONS, EXISTING PIPING, EXISTING ELECTRICAL, AND EXISTING SUPPORTS.
A - EACH DRAWING SHEET AND THE SPECIFICATIONS HAVE BEEN PREPARED TO SUPPLEMENT
EACH OTHER AND THEY SHALL BE INTERPRETED AS AN INTEGRAL UNIT WITH ITEMS SHOWN
AND NOTED ON ONE AND NOT THE OTHER BEING FURNISHED AND INSTALLED AS THOUGH
SHOWN AND CALLED OUT IN ALL PLACES. ITEMS IN SPECIFICATIONS OR DRAWINGS LISTED
WHICH ARE DIFFERING IN EFFICIENCY OR QUALITY SHALL BE HELD TO THE GREATEST OF:
EFFICIENCY, QUALITY OR GOVERNING CODE.
B - THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE INSTALLATION OF THE SYSTEMS
ACCORDING TO THE TRUE INTENT AND MEANING OF THE CONTRACT DOCUMENTS.
C - THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT WITH PROPER SERVICE ACCESS AND
CLEARANCES ACCORDING TO MANUFACTURERS RECOMMENDATIONS. THE CONTRACTOR SHALL
REVIEW SUPPLIERS BID PACKAGES FOR COMPLETENESS AND COMPLIANCE TO THE
SPECIFICATIONS, SCHEDULES, AND DESIGN INTENT (ALL EQUIPMENT AND METHODS). THE
CONTRACTOR SHALL REMOVE AND REINSTALL CORRECTLY AT HIS OWN EXPENSE ANY
EQUIPMENT NOT IN COMPLIANCE.
D - THE CONTRACTOR SHALL CONSULT MANUFACTURERS INSTALLATION INSTRUCTIONS FOR
SIZES, METHODS, ACCESSORIES, AND CLEARANCES IN SPACE AVAILABLE PRIOR TO BIDDING
PROJECT.
E - ANYTHING NOT CLEAR OR IN CONFLICT WILL BE EXPLAINED BY MAKING APPLICATION TO THE
ENGINEER IN WRITING.
G-2 - ANY AND ALL ALTERATIONS TO THE SYSTEM SHOWN SHALL BE SUBMITTED TO THE
ENGINEER PRIOR TO CHANGES FOR APPROVAL. CONTRACTOR SHALL NOT START ANY CHANGES
UNTIL NOTIFIED IN WRITING. IF CHANGES ARE MADE PRIOR TO APPROVAL CONTRACTOR SHALL TAKE ALL RESPONSIBILITY FOR THE CHANGES MADE AND ALL COSTS RELATING TO FAILURE OR
REPLACEMENT OF ALTERATIONS.
G-3 - CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND LOCATIONS.
G-4 - THE WORKING DRAWINGS ARE DIAGRAMMATIC. THEY DO NOT SHOW EVERY OFFSET,
BEND, OR ELBOW NECESSARY FOR THE COMPLETE INSTALLATION IN THE SPACE PROVIDED. ALL
LOCATIONS FOR MECHANICAL EQUIPMENT SHALL BE FIELD VERIFIED AND COORDINATED WITH
ALL DRAWINGS. THE CONTRACTOR SHALL PROVIDE OR COORDINATE WITH THE GENERAL
CONTRACTOR PROVISIONS FOR BLOCKOUTS OR CORE DRILLS THROUGH STRUCTURE.
G-5 - THE INSTRUCTION TO "PROVIDE" ALSO INCLUDES INSTALLATION.
G-6 - MECHANICAL CONTRACTOR SHALL PROVIDE AND INSTALL SMOKE AND FIRE DAMPERS AS
REQUIRED BY LOCAL CODES AND AUTHORITIES.
G-7 - SHEET METAL DUCT SIZES SHOWN ON DRAWINGS ARE FREE AREA DIMENSIONS.
G-8 - PROVIDE TURNING VANES IN ALL ELBOWS OF RECTANGULAR DUCT.
G-9 - THE CONTRACTOR SHALL ASSUME ALL RESPONSIBILITY IN HANDLING AND DISPOSING OF REFRIGERANTS, OILS, ETC. ALL SUCH MATERIALS SHALL BE HANDLED, DISPOSED, AND USED IN
ACCORDANCE WITH ALL LOCAL, STATE, AND FEDERAL LAWS.
G-10 - THE MECHANICAL CONTRACTOR SHALL VERIFY MOTOR VOLTAGES WITH THE ELECTRICAL
DRAWING BEFORE ORDERING MOTORIZED EQUIPMENT AND CONTROLS.
G-11 - C.F.M. LISTED IS ACTUAL AIR.
G-12 - SUPPLIERS SHALL REVIEW ALL DRAWINGS AND THE SPECIFICATIONS PRIOR TO
SUBMITTING PRICES TO THE CONTRACTOR. ALL QUESTIONS AND DISCREPANCIES SHALL BE
BROUGHT TO THE ENGINEERS ATTENTION PRIOR TO BIDDING.
G-13 - CONTRACTOR SHALL THOROUGHLY REVIEW AND SIGN SUBMITTALS FOR COMPLETENESS
AND COMPLIANCE TO THE SPECIFICATIONS PRIOR TO ENGINEERS REVIEW. SUPPLIERS SHALL
HIGHLIGHT OR MARK ALL INFORMATION REQUIRED TO SHOW COMPLIANCE TO THE
SPECIFICATIONS. ALL REQUESTED EXCEPTIONS TO THE SPECIFICATIONS, OR SCHEDULES
SHALL BE CLEARLY NOTED AND EXPLAINED. SUBMITTAL REVIEW AND ACCEPTANCE IS FOR
DESIGN CONCEPT ONLY, AND DOES NOT AT ANY TIME RELIEVE THE CONTRACTOR OF
RESPONSIBILITY TO MEET SPECIFICATIONS, CAPACITIES, OR DESIGN INTENT.
G-14 - ALL MECHANICAL SHALL BE INSTALLED AND CONFORM TO THE 2021 EDITION OF THE IMC
AND IPC WITH UTAH ANNOTATIONS AND LOCAL AUTHORITY REQUIREMENTS.
G-15 - THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE DRAINING DOWN AND RE-FILLING
OF ALL SYSTEMS NECESSARY TO COMPLETE THE WORK OUTLINED BY THIS PROJECT. THIS
INCLUDES PROVIDING THE REQUIRED CHEMICAL TREATMENT WHEN RE-FILLING THE SYSTEM.
G-16 - ALL PIPING, MATERIALS, ETC. SHALL BE NEW AND DOMESTIC MADE UNLESS SPECIFICALLY
AUTHORIZED IN WRITING PRIOR TO BID.
G-17 - PROVIDE FIRE SPRINKLER MODIFICATIONS PER PERFORMANCE SPECIFICATION THROUGH
NICET LEVEL 3 CERTIFIED DESIGN BUILD FIRE SPRINKLER CONTRACTOR.
G-18 - THIS CONTRACTOR SHALL CONTRACT WITH A DESIGN BUILD ELECTRICAL CONTRACTOR
FOR THE DESIGN AND CONSTRUCTION OF THE ELECTRICAL PORTION OF THIS PROJECT.
ELECTRICAL INSTALLATION AND DESIGN SHALL BE PER 2023 NEC.
PLUMBING GENERAL NOTES
G-1 - ALL PLUMBING SHALL BE INSTALLED AND CONFORM TO THE 2021 EDITION OF
THE INTERNATIONAL PLUMBING CODE (IPC) WITH UTAH ANNOTATIONS AND LOCAL
AUTHORITY REQUIREMENTS.
G-2 - ALL PIPING MATERIALS SHALL MEET ALL REQUIREMENTS OF IPC AND LOCAL
AUTHORITY. PLASTIC PIPING SHALL BE ALLOWED ONLY WHERE ALLOWED BY CODE.
PLASTIC PIPING SHALL NOT BE ROUTED THROUGH RETURN AIR PLENUMS OR
OTHER AREAS PROHIBITED BY THE IMC, IPC, OR NFPA CODES OR BY LOCAL
AUTHORITY.
G-3 - GAS PIPING INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH GAS
COMPANY REGULATIONS, NFPA CODE REQUIREMENTS, AND LOCAL AUTHORITY.
G-4 - ALL MATERIALS SHALL BE NEW AND SHALL BE DOMESTIC MADE UNLESS
SPECIFICALLY APPROVED OTHERWISE IN WRITING BY ARCHITECT OR OWNER.
G-5 - PROVIDE VACUUM BREAKERS AND BACK FLOW PREVENTERS WHERE
REQUIRED BY CODE OR WHERE THERE MAY BE ANY POSSIBLE CHANCE FOR CROSS
CONTAMINATION. PREVENTERS SHALL BE INSTALLED IN ACCORDANCE WITH UTAH
CODE.
G-6 - ALL PLUMBING INFORMATION IS NOT LIMITED TO THE PLUMBING DRAWINGS.
CONTRACTOR SHALL BE RESPONSIBLE FOR INFORMATION ON ALL OTHER
CONSTRUCTION DOCUMENTS INCLUDING SPECIFICATIONS, ARCHITECTURAL
DRAWING, STRUCTURAL DRAWINGS, MECHANICAL DRAWINGS, AND ELECTRICAL
DRAWINGS.
G-7 - THE WORKING DRAWINGS ARE DIAGRAMMATIC. BECAUSE OF THE SMALL
SCALE OF THE DRAWING, THEY DO NOT SHOW EVERY OFFSET, BEND OR ELBOW
NECESSARY FOR THE COMPLETE INSTALLATION IN THE SPACE PROVIDED. ALL
PIPING SHALL BE CHECKED AND COORDINATED WITH THE SPECIFICATIONS,
ARCHITECTURAL, STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS.
G-8 - COORDINATE ALL PIPING AND PLUMBING EQUIPMENT WITH ALL OTHER
TRADES AND/OR CONTRACTORS PRIOR TO INSTALLATION.
G-9 - ANY AND ALL ALTERATIONS TO THE SYSTEM SHOWN SHALL BE THE
RESPONSIBILITY OF THIS CONTRACTOR AND ARCHITECT/ENGINEER SHALL BE
NOTIFIED IN WRITING PRIOR TO CHANGES.
G-10 - GAS LINE FITTINGS SHALL BE STANDARD WELD FITTINGS WITH TAPERED
REDUCERS. DO NOT USE VALVES, UNIONS, OR AUTO CONTROLS IN GAS LINES
ROUTED IN INACCESSIBLE CONCEALED SPACES.
G-11 - ALL WATER SYSTEMS SHALL MEET THE REQUIREMENTS OF ANSI/NSF
STANDARD 61 SECTION 9 (1998), CONCERNING METAL CONTAMINANTS IN THE
WATER SYSTEM.
G-12 - WATER PIPING SHALL NOT BE ROUTED IN OUTSIDE WALLS OR ON EXTERIOR
SIDE OF BUILDING INSULATION ENVELOPE.
G-13 - WATER HAMMER ARRESTORS SHALL BE INSTALLED IN ALL WATER LINES
WITH QUICK OPEN OR QUICK CLOSE VALVES.
WATER HAMMER ARRESTOR SCHEDULE:
TYPE A 1-11 FIXTURE UNITS
TYPE B 12-32 FIXTURE UNITS
TYPE C 33-60 FIXTURE UNITS
TYPE D 61-113 FIXTURE UNITS
G-14 - ALL PIPING, MATERIALS, ETC. SHALL BE NEW AND DOMESTIC MADE UNLESS
SPECIFICALLY AUTHORIZED IN WRITING PRIOR TO BID.
JOHN M.
LARSEN
No. 12199025
P R
O
FE
SSIONAL ENG
IN
E
E R
S T
A T E O F
U T
A H
A
LL
ID
E
A S
, D E
S
IG
N S
A
R R
A N
G E
M E
N T
S A
N D
P
LA
N S
IN
D
IC
A
T E
D O
R R
E P
R E
S E
N T
E D
B Y
T H
IS
D
R A
W
IN
G A
R E
O W
N E
D B
Y A
N D
T H
E P
R O
P E
R T
Y O
F W
H W
E N
G
IN
E E
R
IN
G
IN
C . A
N D
W E
R E
C R
E A
T E
D , E
V O
LV
E
D , A
N D
D E
V E
LO
P
E D
F O
R U
S E
O N
A N
D
IN
C O
N N
E C
T
IO
N W
IT
H
T H
E S
P E
C
IF
IE
D
P R
O
JE
C T
N
O N
E O
F T
H E
ID
E
A S
D
E S
IG
N
S
A R
R A
N G
E M
E N
T S
O R
P
LA
N S
S H
A
LL
B E
U S
E D
B Y
O R
D
IS
C
LO
S E
D T
O A
N Y
P E
R S
O N
, F
IR
M
O R
C O
R P
O R
A T
IO
N
F O
R A
N Y
P U
R P
O S
E W
H A
T S
O E
V E
R W
IT
H
O U
T W
R
IT
T E
N C
O N
S E
N T
O F
W H
W E
N G
IN
E
E R
IN
G
IN
C
W
R
IT
T E
N D
IM
E
N S
IO
N
S O
N T
H E
S E
D R
A W
IN
G
S S
H A
LL
H
A V
E P
R E
C E
D E
N C
E O
V E
R S
C A
LE
D
IM
E
N S
IO
N
S
C O
N T
R A
C T
O R
S S
H A
LL
V
E R
IF
Y
A N
D B
E R
E S
P O
N S
IB
LE
F O
R A
LL
D
IM
E
N S
IO
N
S A
N D
C O
N D
IT
IO
N S
O N
T H
E J
O B
A N
D T
H
IS
O F
F
IC
E M
U S
T B
E N
O T
IF
IE
D O
F A
N Y
V A
R
IA
T
IO
N F
R O
M T
H E
D
IM
E N
S
IO
N S
A N
D C
O N
D
IT
IO
N
S S
H O
W N
B Y
T H
E S
E D
R A
W
IN
G S
W
A R
N
IN
G : R
E P
R O
D U
C T
IO
N
H E
R E
O F
IS
A
C R
IM
IN
A L
O F
F E
N S
E U
N D
E R
U .S
.C . S
E C
. 5
. U N
A U
T H
O R
IZ
E
D D
IS
C
LO
S
U R
E M
A Y
C O
N S
T
IT
U T
E T
R A
D E
S E
C R
E T
M
IS
A P
P R
O P
R
IA
T
IO
N
IN
V
IO
LA
T
IO
N
O F
I.
C
.2 4-
2-
-1 E
T . S
E Q
. A N
D O
T H
E R
L A
W S
CONSULTANTS
PROJECT NAME & ADDRESS
CODE REVIEW STAMP
SHEET NO.
PROJECT MANAGER:
DATE:
CHECKED BY:
DRAWN BY:
REVISIONDATEMARK
02/25/2026
WHW JOB NO.:
25117
A
B
C
D
1 2 3
1 2 3
A
B
C
D
SHEET TITLE
JL
JL
UTNG 6150
HVAC
UPGRADES
17800 1700 W, BLUFFDALE, UT 84065
DD
DFCM#26327480
02/25/2026
MECHANICAL
LEGEND AND
GENERAL NOTES
MG001
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
REVIEWED FOR
CODE COMPLIANCE
CLASSROOM
CLASSROOM
3 4
JOHN M.
LARSEN
No. 12199025
P R
O
FE
SSIONAL ENG
IN
E
E R
S T
A T E O F
U T
A H
A
LL
ID
E
A S
, D E
S
IG
N S
A
R R
A N
G E
M E
N T
S A
N D
P
LA
N S
IN
D
IC
A
T E
D O
R R
E P
R E
S E
N T
E D
B Y
T H
IS
D
R A
W
IN
G A
R E
O W
N E
D B
Y A
N D
T H
E P
R O
P E
R T
Y O
F W
H W
E N
G
IN
E E
R
IN
G
IN
C . A
N D
W E
R E
C R
E A
T E
D , E
V O
LV
E
D , A
N D
D E
V E
LO
P
E D
F O
R U
S E
O N
A N
D
IN
C O
N N
E C
T
IO
N W
IT
H
T H
E S
P E
C
IF
IE
D
P R
O
JE
C T
N
O N
E O
F T
H E
ID
E
A S
D
E S
IG
N
S
A R
R A
N G
E M
E N
T S
O R
P
LA
N S
S H
A
LL
B E
U S
E D
B Y
O R
D
IS
C
LO
S E
D T
O A
N Y
P E
R S
O N
, F
IR
M
O R
C O
R P
O R
A T
IO
N
F O
R A
N Y
P U
R P
O S
E W
H A
T S
O E
V E
R W
IT
H
O U
T W
R
IT
T E
N C
O N
S E
N T
O F
W H
W E
N G
IN
E
E R
IN
G
IN
C
W
R
IT
T E
N D
IM
E
N S
IO
N
S O
N T
H E
S E
D R
A W
IN
G
S S
H A
LL
H
A V
E P
R E
C E
D E
N C
E O
V E
R S
C A
LE
D
IM
E
N S
IO
N
S
C O
N T
R A
C T
O R
S S
H A
LL
V
E R
IF
Y
A N
D B
E R
E S
P O
N S
IB
LE
F O
R A
LL
D
IM
E
N S
IO
N
S A
N D
C O
N D
IT
IO
N S
O N
T H
E J
O B
A N
D T
H
IS
O F
F
IC
E M
U S
T B
E N
O T
IF
IE
D O
F A
N Y
V A
R
IA
T
IO
N F
R O
M T
H E
D
IM
E N
S
IO
N S
A N
D C
O N
D
IT
IO
N
S S
H O
W N
B Y
T H
E S
E D
R A
W
IN
G S
W
A R
N
IN
G : R
E P
R O
D U
C T
IO
N
H E
R E
O F
IS
A
C R
IM
IN
A L
O F
F E
N S
E U
N D
E R
U .S
.C . S
E C
. 5
. U N
A U
T H
O R
IZ
E
D D
IS
C
LO
S
U R
E M
A Y
C O
N S
T
IT
U T
E T
R A
D E
S E
C R
E T
M
IS
A P
P R
O P
R
IA
T
IO
N
IN
V
IO
LA
T
IO
N
O F
I.
C
.2 4-
2-
-1 E
T . S
E Q
. A N
D O
T H
E R
L A
W S
CONSULTANTS
PROJECT NAME & ADDRESS
CODE REVIEW STAMP
SHEET NO.
PROJECT MANAGER:
DATE:
CHECKED BY:
DRAWN BY:
REVISIONDATEMARK
02/25/2026
WHW JOB NO.:
25117
A
B
C
D
1 2 3
1 2 3
A
B
C
D
SHEET TITLE
JL
JL
UTNG 6150
HVAC
UPGRADES
17800 1700 W, BLUFFDALE, UT 84065
DD
DFCM#26327480
02/25/2026
MEZZANINE
DEMOLITION PLAN
MD101
3/16" = 1'-0"
MEZZANINE DEMOLITION PLAN
SHEET NOTES
1 REMOVE EXISTING SUPPLY DUCTWORK AS
NECESSARY FOR COMPLETE REMOVAL OF EXISTING
ROOF TOP UNIT ABOVE. FIELD VERIFY EXACT
ROUTING AND POINT OF REMOVAL.
2 REMOVE EXISTING RETURN DUCTWORK AS
NECESSARY FOR COMPLETE REMOVAL OF EXISTING
ROOF TOP UNIT ABOVE. FIELD VERIFY EXACT
ROUTING AND POINT OF REMOVAL.
3 REMOVE AND REPLACE EXISTING DUCT MOUNTED
SMOKE DETECTOR. TIE NEW SMOKE DETECTOR INTO
EXISTING FIRE PANEL. FIELD VERIFY.
4 REMOVE EXISTING RADIANT TUBE HEATER AND ALL
ASSOCIATED ITEMS IN THIS APPROXIMATE
LOCATION. PROTECT AND PROVIDE TO OWER (DPW)
FOR LATER INSTALLATION. REMOVE GAS PIPING
BACK TO THE MAIN AND CAP. REMOVE FLUE PIPE
AND PATCH AND REPAIR WALL PENETRATION TO
MATCH BUILDING STANDARD. FIELD VERIFY.
5 REMOVE EXISTING CONTROLS AND ALL ASSOCIATED
ITEMS IN THIS APPROXIMATE LOCATION. RE-INTALL
COMPONENTS IN OWER FURNISHED CABINET. FIELD
VERIFY.
6 REMOVE EXISTING UNIT HEATER AND ALL
ASSOCIATED ITEMS IN THIS APPROXIMATE
LOCATION. FIELD VERIFY.
GENERAL NOTES:
1. CONTRACTOR SHALL FIELD VERIFY EXISTING
MECHANICAL, STRUCTURAL, ELECTRICAL AND
ARCHITECTURAL CONDITIONS, INCLUDING, BUT NOT
LIMITED TO: EXISTING ROUTING AND LOCATION OF
DUCTWORK, PIPING, ELECTRICAL AND STRUCTURAL
ELEMENTS. CONTRACTOR SHALL FIELD VERIFY
POTENTIAL CONFLICTS BETWEEN NEW MECHANICAL
ELEMENTS AND EXISTING CONDITIONS PRIOR TO
BEGINNING FABRICATION OR ORDERING
EQUIPMENT.
2. ALL DEMOLISHED EQUIPMENT AND MATERIAL
SHALL BE BROKEN DOWN TO FIT THROUGH EXISTING
DOOR, OPENINGS, HATCHES. FIELD VERIFY EXACT
SCOPE OF DEMOLITION AND REMOVAL PATH.
CONTRACTOR SHALL BE RESPONSIBLE TO REPAIR
ANY DAMAGE TO BUILDING DURING REMOVAL OF
EQUIPMENT AND MATERIAL.
3. CONTRACTOR SHALL COORDINATE WITH DFCM
PROVIDED HAZMAT CONTRACTOR PRIOR TO THE
DEMOLITION OF ANY EQUIPMENT, DUCTWORK, DUCT
INSULATION, PIPING, PIPE INSULATION, ETC.
4. PRIME CONTRACTOR SHALL PROVIDE ALL
COORDINATION BETWEEN SUB-TIER CONTRACTORS.
THIS SHALL INCLUDE THE COORDINATION BETWEEN
SUB-TIER CONTRACTORS, SUB-TIER CONTRACTORS
AND FACILITIES, SUB-TIER CONTRACTORS AND
ARCHITECT/ENGINEER, ETC.
0' 16'2'-8" 5'-4" 10'-8
SCALE : 3/16" = 1'-0"
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
REVIEWED FOR
CODE COMPLIANCE
1 1
1 1
JOHN M.
LARSEN
No. 12199025
P R
O
FE
SSIONAL ENG
IN
E
E R
S T
A T E O F
U T
A H
A
LL
ID
E
A S
, D E
S
IG
N S
A
R R
A N
G E
M E
N T
S A
N D
P
LA
N S
IN
D
IC
A
T E
D O
R R
E P
R E
S E
N T
E D
B Y
T H
IS
D
R A
W
IN
G A
R E
O W
N E
D B
Y A
N D
T H
E P
R O
P E
R T
Y O
F W
H W
E N
G
IN
E E
R
IN
G
IN
C . A
N D
W E
R E
C R
E A
T E
D , E
V O
LV
E
D , A
N D
D E
V E
LO
P
E D
F O
R U
S E
O N
A N
D
IN
C O
N N
E C
T
IO
N W
IT
H
T H
E S
P E
C
IF
IE
D
P R
O
JE
C T
N
O N
E O
F T
H E
ID
E
A S
D
E S
IG
N
S
A R
R A
N G
E M
E N
T S
O R
P
LA
N S
S H
A
LL
B E
U S
E D
B Y
O R
D
IS
C
LO
S E
D T
O A
N Y
P E
R S
O N
, F
IR
M
O R
C O
R P
O R
A T
IO
N
F O
R A
N Y
P U
R P
O S
E W
H A
T S
O E
V E
R W
IT
H
O U
T W
R
IT
T E
N C
O N
S E
N T
O F
W H
W E
N G
IN
E
E R
IN
G
IN
C
W
R
IT
T E
N D
IM
E
N S
IO
N
S O
N T
H E
S E
D R
A W
IN
G
S S
H A
LL
H
A V
E P
R E
C E
D E
N C
E O
V E
R S
C A
LE
D
IM
E
N S
IO
N
S
C O
N T
R A
C T
O R
S S
H A
LL
V
E R
IF
Y
A N
D B
E R
E S
P O
N S
IB
LE
F O
R A
LL
D
IM
E
N S
IO
N
S A
N D
C O
N D
IT
IO
N S
O N
T H
E J
O B
A N
D T
H
IS
O F
F
IC
E M
U S
T B
E N
O T
IF
IE
D O
F A
N Y
V A
R
IA
T
IO
N F
R O
M T
H E
D
IM
E N
S
IO
N S
A N
D C
O N
D
IT
IO
N
S S
H O
W N
B Y
T H
E S
E D
R A
W
IN
G S
W
A R
N
IN
G : R
E P
R O
D U
C T
IO
N
H E
R E
O F
IS
A
C R
IM
IN
A L
O F
F E
N S
E U
N D
E R
U .S
.C . S
E C
. 5
. U N
A U
T H
O R
IZ
E
D D
IS
C
LO
S
U R
E M
A Y
C O
N S
T
IT
U T
E T
R A
D E
S E
C R
E T
M
IS
A P
P R
O P
R
IA
T
IO
N
IN
V
IO
LA
T
IO
N
O F
I.
C
.2 4-
2-
-1 E
T . S
E Q
. A N
D O
T H
E R
L A
W S
CONSULTANTS
PROJECT NAME & ADDRESS
CODE REVIEW STAMP
SHEET NO.
PROJECT MANAGER:
DATE:
CHECKED BY:
DRAWN BY:
REVISIONDATEMARK
02/25/2026
WHW JOB NO.:
25117
A
B
C
D
1 2 3
1 2 3
A
B
C
D
SHEET TITLE
JL
JL
UTNG 6150
HVAC
UPGRADES
17800 1700 W, BLUFFDALE, UT 84065
DD
DFCM#26327480
02/25/2026
ROOFTOP
DEMOLITION PLAN
MD102
SHEET NOTES
1 REMOVE EXISTING RTU IN THIS APPROXIMATE
LOCATION. REMOVE EXISTING ELECTRICAL
ACCOMMODATIONS BACK TO PANEL. DISCONNECT
FROM EXISTING RETURN AND SUPPLY DUCTWORK.
REMOVE EXISTING CONTROLS AND WIRING BACK TO
EXISTING PANEL. FIELD VERIFY EXACT POINTS OF
REMOVAL.
GENERAL NOTES:
1. CONTRACTOR SHALL FIELD VERIFY EXISTING
MECHANICAL, STRUCTURAL, ELECTRICAL AND
ARCHITECTURAL CONDITIONS, INCLUDING, BUT NOT
LIMITED TO: EXISTING ROUTING AND LOCATION OF
DUCTWORK, PIPING, ELECTRICAL AND STRUCTURAL
ELEMENTS. CONTRACTOR SHALL FIELD VERIFY
POTENTIAL CONFLICTS BETWEEN NEW MECHANICAL
ELEMENTS AND EXISTING CONDITIONS PRIOR TO
BEGINNING FABRICATION OR ORDERING
EQUIPMENT.
2. ALL DEMOLISHED EQUIPMENT AND MATERIAL
SHALL BE BROKEN DOWN TO FIT THROUGH EXISTING
DOOR, OPENINGS, HATCHES. FIELD VERIFY EXACT
SCOPE OF DEMOLITION AND REMOVAL PATH.
CONTRACTOR SHALL BE RESPONSIBLE TO REPAIR
ANY DAMAGE TO BUILDING DURING REMOVAL OF
EQUIPMENT AND MATERIAL.
3. CONTRACTOR SHALL COORDINATE WITH DFCM
PROVIDED HAZMAT CONTRACTOR PRIOR TO THE
DEMOLITION OF ANY EQUIPMENT, DUCTWORK, DUCT
INSULATION, PIPING, PIPE INSULATION, ETC.
4. PRIME CONTRACTOR SHALL PROVIDE ALL
COORDINATION BETWEEN SUB-TIER CONTRACTORS.
THIS SHALL INCLUDE THE COORDINATION BETWEEN
SUB-TIER CONTRACTORS, SUB-TIER CONTRACTORS
AND FACILITIES, SUB-TIER CONTRACTORS AND
ARCHITECT/ENGINEER, ETC.
3/16" = 1'-0"
ROOFTOP DEMOLITION PLAN
0' 16'2'-8" 5'-4" 10'-8
SCALE : 3/16" = 1'-0"
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
REVIEWED FOR
CODE COMPLIANCE
CLASSROOM
CLASSROOM
1/2"ø NG
1/2"ø NG
1/2"ø NG
1/2"ø NG
EXIST
EXIST
EXIST
EXIST
EXIST
EXIST
EXIST
EXIST
EXIST
EXIST
EXIST
EXIST
EXIST
EXIST
EXIST
EXIST
2 2
2 2
2 2 2 2
2 2
2 2
1/2"ø NG
1/2"ø NG
T
RTU-2
T
RTU-1
T
RTU-3
T
RTU-4
T
RTU-5
STORAGE
CLASSROOM
MECH ROOM
MEN
WOMEN
LOBBY
MECH
VEST
MECH
UNISEX RR
STORAGE ROOM
HALLWAY
COMM ROOM
JOHN M.
LARSEN
No. 12199025
P R
O
FE
SSIONAL ENG
IN
E
E R
S T
A T E O F
U T
A H
A
LL
ID
E
A S
, D E
S
IG
N S
A
R R
A N
G E
M E
N T
S A
N D
P
LA
N S
IN
D
IC
A
T E
D O
R R
E P
R E
S E
N T
E D
B Y
T H
IS
D
R A
W
IN
G A
R E
O W
N E
D B
Y A
N D
T H
E P
R O
P E
R T
Y O
F W
H W
E N
G
IN
E E
R
IN
G
IN
C . A
N D
W E
R E
C R
E A
T E
D , E
V O
LV
E
D , A
N D
D E
V E
LO
P
E D
F O
R U
S E
O N
A N
D
IN
C O
N N
E C
T
IO
N W
IT
H
T H
E S
P E
C
IF
IE
D
P R
O
JE
C T
N
O N
E O
F T
H E
ID
E
A S
D
E S
IG
N
S
A R
R A
N G
E M
E N
T S
O R
P
LA
N S
S H
A
LL
B E
U S
E D
B Y
O R
D
IS
C
LO
S E
D T
O A
N Y
P E
R S
O N
, F
IR
M
O R
C O
R P
O R
A T
IO
N
F O
R A
N Y
P U
R P
O S
E W
H A
T S
O E
V E
R W
IT
H
O U
T W
R
IT
T E
N C
O N
S E
N T
O F
W H
W E
N G
IN
E
E R
IN
G
IN
C
W
R
IT
T E
N D
IM
E
N S
IO
N
S O
N T
H E
S E
D R
A W
IN
G
S S
H A
LL
H
A V
E P
R E
C E
D E
N C
E O
V E
R S
C A
LE
D
IM
E
N S
IO
N
S
C O
N T
R A
C T
O R
S S
H A
LL
V
E R
IF
Y
A N
D B
E R
E S
P O
N S
IB
LE
F O
R A
LL
D
IM
E
N S
IO
N
S A
N D
C O
N D
IT
IO
N S
O N
T H
E J
O B
A N
D T
H
IS
O F
F
IC
E M
U S
T B
E N
O T
IF
IE
D O
F A
N Y
V A
R
IA
T
IO
N F
R O
M T
H E
D
IM
E N
S
IO
N S
A N
D C
O N
D
IT
IO
N
S S
H O
W N
B Y
T H
E S
E D
R A
W
IN
G S
W
A R
N
IN
G : R
E P
R O
D U
C T
IO
N
H E
R E
O F
IS
A
C R
IM
IN
A L
O F
F E
N S
E U
N D
E R
U .S
.C . S
E C
. 5
. U N
A U
T H
O R
IZ
E
D D
IS
C
LO
S
U R
E M
A Y
C O
N S
T
IT
U T
E T
R A
D E
S E
C R
E T
M
IS
A P
P R
O P
R
IA
T
IO
N
IN
V
IO
LA
T
IO
N
O F
I.
C
.2 4-
2-
-1 E
T . S
E Q
. A N
D O
T H
E R
L A
W S
CONSULTANTS
PROJECT NAME & ADDRESS
CODE REVIEW STAMP
SHEET NO.
PROJECT MANAGER:
DATE:
CHECKED BY:
DRAWN BY:
REVISIONDATEMARK
02/25/2026
WHW JOB NO.:
25117
A
B
C
D
1 2 3
1 2 3
A
B
C
D
SHEET TITLE
JL
JL
UTNG 6150
HVAC
UPGRADES
17800 1700 W, BLUFFDALE, UT 84065
DD
DFCM#26327480
02/25/2026
MEZZANINE
MECHANICAL PLAN
ME101
3/16" = 1'-0"
MEZZANINE MECHANICAL PLAN
SHEET NOTES
1 TIE EXISTING DUCT RISERS INTO NEW ROOF TOP
UNIT ABOVE IN THIS APPROXIMATE LOCATION.
PROVIDE TRANSITIONS AS NECESSARY FOR A
COMPLETE INSTALL. FIELD VERIFY EXACT ROUTING
AND POINTS OF CONNECTION.
2 TEST AND BALANCE EXISTING SUPPLY AIR DIFFUSER
TO SHOWN CFM.
3 TIE INTO EXISTING GAS PIPING IN THIS APPROXIMATE
LOCATION. FIELD VERIFY EXACT SIZING, ROUTING
AND POINTS OF CONNECTION.
4 PROVIDE NEW GAS PIPING RISER UP THROUGH
ROOF IN THIS APPROXIMATE LOCATION. SEE ME501
FOR DETAILS. ALL ROOFING MODIFICATIONS SHALL
BE PERFORMED BY DFCM APPROVED ROOFING
CONTRACTOR.
5 RELOCATE EXISTING CONTROLS PANEL BOX TO
OWER FURNISHED CABINET AND PROVIDE ALL NEW
BAS CONTROLS IN THIS APPROXIMATE LOCATION.
COORDINATE WITH DESIGN BUILD ELECTRICIAN TO
PROVIDE ALL ELECTRICAL ACCOMODATIONS FOR A
COMPLETE INSTALL.
6 ADD ALT#1: PROVIDE ROOF ACCESS FIXED LADDER
AND HATCH IN THIS APPROXIMATE LOCATION.
PROVIDE 30" WALKING PADS FOR ACCESS TO ROOF
MOUNTED EQUIPMENT. PROVIDE ROOF ANCHOR
SYSTEM WITH HORIZONTAL LIFELINES. PROVIDE
OWNER WITH ROOF FALL PROTECTION KIT. HATCH
SHALL BE ONE-HAND OPERATED WITH GUARD RAIL
AND LADDER-UP BAR.
GENERAL NOTES:
1. CONTRACTOR SHALL FIELD VERIFY EXISTING
MECHANICAL, STRUCTURAL, ELECTRICAL AND
ARCHITECTURAL CONDITIONS, INCLUDING, BUT NOT
LIMITED TO: EXISTING ROUTING AND LOCATION OF
DUCTWORK, PIPING, ELECTRICAL AND STRUCTURAL
ELEMENTS. CONTRACTOR SHALL FIELD VERIFY
POTENTIAL CONFLICTS BETWEEN NEW MECHANICAL
ELEMENTS AND EXISTING CONDITIONS PRIOR TO
BEGINNING FABRICATION OR ORDERING
EQUIPMENT.
2. ALL DEMOLISHED EQUIPMENT AND MATERIAL
SHALL BE BROKEN DOWN TO FIT THROUGH EXISTING
DOOR, OPENINGS, HATCHES. FIELD VERIFY EXACT
SCOPE OF DEMOLITION AND REMOVAL PATH.
CONTRACTOR SHALL BE RESPONSIBLE TO REPAIR
ANY DAMAGE TO BUILDING DURING REMOVAL OF
EQUIPMENT AND MATERIAL.
3. CONTRACTOR SHALL COORDINATE WITH DFCM
PROVIDED HAZMAT CONTRACTOR PRIOR TO THE
DEMOLITION OF ANY EQUIPMENT, DUCTWORK, DUCT
INSULATION, PIPING, PIPE INSULATION, ETC.
4. PRIME CONTRACTOR SHALL PROVIDE ALL
COORDINATION BETWEEN SUB-TIER CONTRACTORS.
THIS SHALL INCLUDE THE COORDINATION BETWEEN
SUB-TIER CONTRACTORS, SUB-TIER CONTRACTORS
AND FACILITIES, SUB-TIER CONTRACTORS AND
ARCHITECT/ENGINEER, ETC.
0' 16'2'-8" 5'-4" 10'-8
SCALE : 3/16" = 1'-0"
3/16" = 1'-0"
MAIN LEVEL MECHANICAL PLAN
0' 16'2'-8" 5'-4" 10'-8
SCALE : 3/16" = 1'-0"
SHEET NOTES
7 STUB IN NEW 1" CONDUIT FROM NEW MECHANICAL
CONTROLS ROOMS BACK TO EXISTING ABOVE IN
CEILINGS.
8 PROVIDE NEW THERMOSTAT IN THIS APPROXIMATE
LOCATION. MOUNT 4' AFF.
9 PROVIDE OCCUPANCY SENSOR IN THIS
APPROXIMATE LOCATION. PROVIDE 4"X6" INGRAVED
SIGN UNDER THERMOSTAT TO READ "PRESS BUTTON
TO OCCUPY SPACE FOR 3 HOURS. FOR ISSUES CALL
(801) 878-5518".
10 REMOVE AND REPLACE CONTROLS TO EXISTING
FURNACE IN THIS APPROXIMATE LOCATION. FIELD
VERIFY.
11 MOVE EXISTING EQUIPMENT FROM COMM ROOM TO
THIS APPROXIMATE LOCATION. FIELD VERIFY.
12 TIE INTO ELECTRICAL SERVICE FROM COMM ROOM.
FIELD VERIFY EXACT ROUTING AND POINTS OF
CONNECTION.
13 PROVIDE NEW 2"X4" WALL WITH SHEETROCK, PAINT
AND FINISH IN THIS APPROXIMATE LOCATION. NEW
WALL SHALL EXTEND A MINIMUM OF 5 FEET FROM
SOUTH WALL. PROVIDE 36"-WIDE DOOR.
COORDINATE WITH OWNER TO MATCH STANDARD
HEIGHT STYLE. REFERENCE DRAWINGS FOR
ORIENTATION.
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
REVIEWED FOR
CODE COMPLIANCE
1TYP. 5
RTU
RTU
RTU
RTU
RTU
2 2
3 3
1/2"ø NG
1/2"ø NG 1/2"ø NG
1/2"ø NG 1/2"ø NG
(CABLE LINE)
JOHN M.
LARSEN
No. 12199025
P R
O
FE
SSIONAL ENG
IN
E
E R
S T
A T E O F
U T
A H
A
LL
ID
E
A S
, D E
S
IG
N S
A
R R
A N
G E
M E
N T
S A
N D
P
LA
N S
IN
D
IC
A
T E
D O
R R
E P
R E
S E
N T
E D
B Y
T H
IS
D
R A
W
IN
G A
R E
O W
N E
D B
Y A
N D
T H
E P
R O
P E
R T
Y O
F W
H W
E N
G
IN
E E
R
IN
G
IN
C . A
N D
W E
R E
C R
E A
T E
D , E
V O
LV
E
D , A
N D
D E
V E
LO
P
E D
F O
R U
S E
O N
A N
D
IN
C O
N N
E C
T
IO
N W
IT
H
T H
E S
P E
C
IF
IE
D
P R
O
JE
C T
N
O N
E O
F T
H E
ID
E
A S
D
E S
IG
N
S
A R
R A
N G
E M
E N
T S
O R
P
LA
N S
S H
A
LL
B E
U S
E D
B Y
O R
D
IS
C
LO
S E
D T
O A
N Y
P E
R S
O N
, F
IR
M
O R
C O
R P
O R
A T
IO
N
F O
R A
N Y
P U
R P
O S
E W
H A
T S
O E
V E
R W
IT
H
O U
T W
R
IT
T E
N C
O N
S E
N T
O F
W H
W E
N G
IN
E
E R
IN
G
IN
C
W
R
IT
T E
N D
IM
E
N S
IO
N
S O
N T
H E
S E
D R
A W
IN
G
S S
H A
LL
H
A V
E P
R E
C E
D E
N C
E O
V E
R S
C A
LE
D
IM
E
N S
IO
N
S
C O
N T
R A
C T
O R
S S
H A
LL
V
E R
IF
Y
A N
D B
E R
E S
P O
N S
IB
LE
F O
R A
LL
D
IM
E
N S
IO
N
S A
N D
C O
N D
IT
IO
N S
O N
T H
E J
O B
A N
D T
H
IS
O F
F
IC
E M
U S
T B
E N
O T
IF
IE
D O
F A
N Y
V A
R
IA
T
IO
N F
R O
M T
H E
D
IM
E N
S
IO
N S
A N
D C
O N
D
IT
IO
N
S S
H O
W N
B Y
T H
E S
E D
R A
W
IN
G S
W
A R
N
IN
G : R
E P
R O
D U
C T
IO
N
H E
R E
O F
IS
A
C R
IM
IN
A L
O F
F E
N S
E U
N D
E R
U .S
.C . S
E C
. 5
. U N
A U
T H
O R
IZ
E
D D
IS
C
LO
S
U R
E M
A Y
C O
N S
T
IT
U T
E T
R A
D E
S E
C R
E T
M
IS
A P
P R
O P
R
IA
T
IO
N
IN
V
IO
LA
T
IO
N
O F
I.
C
.2 4-
2-
-1 E
T . S
E Q
. A N
D O
T H
E R
L A
W S
CONSULTANTS
PROJECT NAME & ADDRESS
CODE REVIEW STAMP
SHEET NO.
PROJECT MANAGER:
DATE:
CHECKED BY:
DRAWN BY:
REVISIONDATEMARK
02/25/2026
WHW JOB NO.:
25117
A
B
C
D
1 2 3
1 2 3
A
B
C
D
SHEET TITLE
JL
JL
UTNG 6150
HVAC
UPGRADES
17800 1700 W, BLUFFDALE, UT 84065
DD
DFCM#26327480
02/25/2026
ROOFTOP
MECHANICAL PLAN
ME102
SHEET NOTES
1 PROVIDE NEW 30" WALKING PADS SURROUNDING
NEW RTU IN THIS APPROXIMATE LOCATION.
2 PROVIDE NEW RTU IN THIS APPROXIMATE LOCATION.
PROVIDE WITH ALL NEW ELECTRICAL
ACCOMMODATIONS BY A LICENSED DESIGN BUILD
ELECTRICIAN. PROVIDE NEW DUCTWORK
TRANSITIONS AS NEEDED TO CONNECT TO NEW RTU.
PROVIDE NEW EQUIPMENT CURB, SEE DETAILS.
FIELD VERIFY DIMENSIONS PRIOR TO COMMENCING
WORK. PROVIDE NEW GAS TRAIN AND PIPING. ALL
ROOFING MODIFICATIONS SHALL BE PERFORMED BY
DFCM APPROVED ROOFING CONTRACTOR. SEE
DETAILS ON SHEET ME501. PAINT ALL EXPOSED GAS
PIPING WITH GREY UV RESISTANT PAINT. FIELD
VERIFY EXACT ROUTING. PROVIDE WITH COIL HAIL
GUARDS. PROVIDE ALL NEW CONTROLS AND WIRING
FOR A FULLY FUNCTIONING SYSTEM. INSTALL PER
MANUFACTURERS RECOMMENDATIONS FOR A
COMPLETE INSTALL.
3 PROVIDE NEW GAS PIPING DROP TO LEVEL BELOW IN
THIS APPROXIMATE LOCATION. SEE ME501 FOR
DETAILS. ALL ROOFING MODIFICATIONS SHALL BE
PERFORMED BY DFCM APPROVED ROOFING
CONTRACTOR.
4 ADD ALT#1: PROVIDE ROOF ACCESS FIXED LADDER
AND HATCH IN THIS APPROXIMATE LOCATION.
PROVIDE 30" WALKING PADS FOR ACCESS TO ROOF
MOUNTED EQUIPMENT. PROVIDE ROOF ANCHOR
SYSTEM WITH HORIZONTAL LIFELINES. PROVIDE
OWNER WITH ROOF FALL PROTECTION KIT. HATCH
SHALL BE ONE-HAND OPERATED WITH GUARD RAIL
AND LADDER-UP BAR.
5 PROVIDE NEW ROOF MOUNTED ANCHOR POSTS TO
RUN LENGTH OF BUILDING FOR SERVICING ROOF
MOUNTED EQUIPMENT. SEE DETAIL.
GENERAL NOTES:
1. CONTRACTOR SHALL FIELD VERIFY EXISTING
MECHANICAL, STRUCTURAL, ELECTRICAL AND
ARCHITECTURAL CONDITIONS, INCLUDING, BUT NOT
LIMITED TO: EXISTING ROUTING AND LOCATION OF
DUCTWORK, PIPING, ELECTRICAL AND STRUCTURAL
ELEMENTS. CONTRACTOR SHALL FIELD VERIFY
POTENTIAL CONFLICTS BETWEEN NEW MECHANICAL
ELEMENTS AND EXISTING CONDITIONS PRIOR TO
BEGINNING FABRICATION OR ORDERING
EQUIPMENT.
2. ALL DEMOLISHED EQUIPMENT AND MATERIAL
SHALL BE BROKEN DOWN TO FIT THROUGH EXISTING
DOOR, OPENINGS, HATCHES. FIELD VERIFY EXACT
SCOPE OF DEMOLITION AND REMOVAL PATH.
CONTRACTOR SHALL BE RESPONSIBLE TO REPAIR
ANY DAMAGE TO BUILDING DURING REMOVAL OF
EQUIPMENT AND MATERIAL.
3. CONTRACTOR SHALL COORDINATE WITH DFCM
PROVIDED HAZMAT CONTRACTOR PRIOR TO THE
DEMOLITION OF ANY EQUIPMENT, DUCTWORK, DUCT
INSULATION, PIPING, PIPE INSULATION, ETC.
4. PRIME CONTRACTOR SHALL PROVIDE ALL
COORDINATION BETWEEN SUB-TIER CONTRACTORS.
THIS SHALL INCLUDE THE COORDINATION BETWEEN
SUB-TIER CONTRACTORS, SUB-TIER CONTRACTORS
AND FACILITIES, SUB-TIER CONTRACTORS AND
ARCHITECT/ENGINEER, ETC.
3/16" = 1'-0"
ROOFTOP MECHANICAL PLAN
0' 16'2'-8" 5'-4" 10'-8
SCALE : 3/16" = 1'-0"
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
REVIEWED FOR
CODE COMPLIANCE
V E
R T
IC
A
L
M
IN
2" MIN
VARIES
2" MIN
2" MIN 2" MIN
1'-0"
2"
A S
R E
Q 'D
C
O O
R D
W
E
Q U
IP
M
E N
T R
E Q
U
IR
E M
E N
T S
ROOFTOP UNIT DETAIL
A2 PIPE/CONDUIT FLASHING DETAIL
A4
ROOF POST DETAIL
B2
PIPE HANGER DETAIL
A1
B1
GAS LINE CONNECTION DETAIL
SCALE: NONE
ROOFTOP UNIT
SS
ECONOMIZER
FACTORY BUILT
ROOF CURB
CANT STRIP &
G.I. FLASHING
FLEX DUCT
CONNECTION
ROOF
CONDENSATE DRAIN AND
TRAP TO ROOF. TYPICAL
SMOKE SENSORS IN ALL SUPPLY
AND RETURN AIR DUCTS ON ALL
UNITS ABOVE 2000 CFM.
EXISTING CURB
TYPICAL
TYPICAL
PIPE / CONDUIT
FLASHING MEMBRANE AND
SEALANT
STAINLESS STEEL CLAMPING
RING
SPM MEMBRANE PRE-FABRICATED
BOOT WITH MINIMUM 1" TURN-UP
CONTINUOUS WELDHEAT WELDED FLASHING
ROOFING MEMBRANE -
VARIES BY PROJECT
RIGID INSULATION -
VARIES BY PROJECT
ROOF DECK VARIES
BY PROJECT
PLUMBING VENT / STACK
FLASHING MEMBRANE
AND SEALANT
STAINLESS STEEL
CLAMPING RING
ADHERED FIELD
FLASHED MEMBRANE
HEAT WELDED
FLASHING
ROOFING MEMBRANE
- VARIES BY PROJECT
RIGID INSULATION -
VARIES BY PROJECT
ROOF DECK VARIES
BY PROJECT
NOTE THAT PITCH POCKETS
ARE NOT AN ACCEPTABLE
METHOD OF WATER-PROOFING
BASE OF PIPES
NOTE:
IF THE TOP OF THE EXISTING VENT IS
LESS THAN 12" ABOVE THE NEW
FINISHED ROOF SURFACE, THE VENT
MUST BE EXTENDED
NOTE THAT WHERE A PIPE IS CAPABLE OF
BEING FLASHED USING A ROOFING
MANUFACTURERS PRE-FABRICATED BOOT
(SUCH AS SHOWN ABOVE), THAT OPTION IS
REQUIRED AND SHOULD BE USED OVER A FIELD
FLASHED DETAIL (SUCH AS SHOWN BELOW)
SCALE: NONE
PLAN VIEW OF STEEL PLATE
CONT. BEAD OF
APPROVED SEALANT
STAINLESS STEEL
CLAMPING RING
FIELD FABRICATED METAL
HOOD
FASTENER
2" MIN. WELDED
SPLICE
CAPPED, 2" DIA. x 3/16" STEEL
PIPE (GALVANIZED) - WELDED
TO STEEL BASE PLATE -
COORDINATE LOCATION AND
HEIGHT WITH OWNER AS
REQ'D. - NOTE: SEAL ANY
HOLES OR OTHER
PENETRATIONS USED FOR THE
GALVANIZING PROCESS
PRE-MOLDED
SPM PIPE
FLASHING
NOTE THAT PITCH POCKETS ARE NOT AN
ACCEPTABLE METHOD OF WATER-PROOFING BASE OF
PIPESROOF DECK
VARIES BY
PROJECT
RIGID INSULATION -
VARIES BY PROJECT
12"x12"x1/4" STEEL PLATE - WELD PIPE TO
PLATE - ATTACH PLATE TO DECK WITH (12) #14
STS (OR APPROPRIATE FASTENERS FOR DECK
TYPE AS DIRECTED BY A STRUCTURAL
ENGINEER)
SCALE: NONE
CLEVIS HANGER
SINGLE HORIZONTAL RUN
WITHOUT INSULATION
CLEVIS HANGER
NOTE:
PROVIDE WITH VAPOR BARRIER
ON CHILLED WATER AND
DOMESTIC COLD WATER PIPING
HANGER
ATTACH TO ROOM
OVERHEAD STRUCTURE
SPRING TYPE ISOLATOR
FOR INSTALLATION NEAR
HOT WATER PUMPS
ATTACH TO EXISTING
CEILING
HANGER ROD
HEAVY DUTY
CLEVIS HANGER
PIPE
HANGER ROD
HEAVY DUTY
CLEVIS HANGER
SUPPORT NUT
LOCKING NUT
INSULATION
LOCKING NUT
SUPPORT NUT
PIPE
16 GAGE ZINC COATED
SHEET STEEL SHIELD
AT LEAST 12" LONG.
CALCIUM SILICATE BLOCK
SCALE: NONE
WELD EYE BOLT
ANCHOR TO
POST 8" AFF
EYE BOLT 1-5/32" EYE DIA
WITH CABLE CLAMPS AND 1/4"
CABLING TO FOLLOW
SERVICE PATH ON ROOF
SCALE: NONE
MANUAL
SHUT-OFF
VALVE
DRIP LEG
GAS
PRESSURE
REGULATOR
FLEXIBLE GAS
CONNECTOR
18" MAX.
GROUND
JOINT
UNION
GAS
SUPPLY
EQUIPMENT
CONNECTION
1. PROVIDE SMOKE DETECTOR IN SUPPLY AND RETURN AIR FOR ALL UNITS OVER 2,000 CFM.
2. RATED MINIMUM INPUT AT 4500FT.
3. PROVIDE ONE 15 AMP, 120 VOLT, DUPLEX GFCI SERVICE OUTLET. FACTORY INSTALLED, FIELD WIRED.
4. ESP DOES NOT INCLUDE LOSSES THROUGH ACCESSORIES.
5. SEISMIC HOLD DOWN CLIPS.
6. PROVIDE 100% OUTSIDE AIR ECONOMIZER.
7. SEE SPECIFICATIONS FOR OTHER APPROVED MANUFACTURERS.
8. REFRIGERANT R-454B.
9. PROVIDE WITH POWERED EXHAUST.
10. PROVIDE WITH COIL HAIL GUARDS.
11. COORDINATE WITH ELECTRICAL TO PROVIDE VOLTAGE AND PHASE MONITORS TO PROTECT COMPRESSORS.
JOHN M.
LARSEN
No. 12199025
P R
O
FE
SSIONAL ENG
IN
E
E R
S T
A T E O F
U T
A H
A
LL
ID
E
A S
, D E
S
IG
N S
A
R R
A N
G E
M E
N T
S A
N D
P
LA
N S
IN
D
IC
A
T E
D O
R R
E P
R E
S E
N T
E D
B Y
T H
IS
D
R A
W
IN
G A
R E
O W
N E
D B
Y A
N D
T H
E P
R O
P E
R T
Y O
F W
H W
E N
G
IN
E E
R
IN
G
IN
C . A
N D
W E
R E
C R
E A
T E
D , E
V O
LV
E
D , A
N D
D E
V E
LO
P
E D
F O
R U
S E
O N
A N
D
IN
C O
N N
E C
T
IO
N W
IT
H
T H
E S
P E
C
IF
IE
D
P R
O
JE
C T
N
O N
E O
F T
H E
ID
E
A S
D
E S
IG
N
S
A R
R A
N G
E M
E N
T S
O R
P
LA
N S
S H
A
LL
B E
U S
E D
B Y
O R
D
IS
C
LO
S E
D T
O A
N Y
P E
R S
O N
, F
IR
M
O R
C O
R P
O R
A T
IO
N
F O
R A
N Y
P U
R P
O S
E W
H A
T S
O E
V E
R W
IT
H
O U
T W
R
IT
T E
N C
O N
S E
N T
O F
W H
W E
N G
IN
E
E R
IN
G
IN
C
W
R
IT
T E
N D
IM
E
N S
IO
N
S O
N T
H E
S E
D R
A W
IN
G
S S
H A
LL
H
A V
E P
R E
C E
D E
N C
E O
V E
R S
C A
LE
D
IM
E
N S
IO
N
S
C O
N T
R A
C T
O R
S S
H A
LL
V
E R
IF
Y
A N
D B
E R
E S
P O
N S
IB
LE
F O
R A
LL
D
IM
E
N S
IO
N
S A
N D
C O
N D
IT
IO
N S
O N
T H
E J
O B
A N
D T
H
IS
O F
F
IC
E M
U S
T B
E N
O T
IF
IE
D O
F A
N Y
V A
R
IA
T
IO
N F
R O
M T
H E
D
IM
E N
S
IO
N S
A N
D C
O N
D
IT
IO
N
S S
H O
W N
B Y
T H
E S
E D
R A
W
IN
G S
W
A R
N
IN
G : R
E P
R O
D U
C T
IO
N
H E
R E
O F
IS
A
C R
IM
IN
A L
O F
F E
N S
E U
N D
E R
U .S
.C . S
E C
. 5
. U N
A U
T H
O R
IZ
E
D D
IS
C
LO
S
U R
E M
A Y
C O
N S
T
IT
U T
E T
R A
D E
S E
C R
E T
M
IS
A P
P R
O P
R
IA
T
IO
N
IN
V
IO
LA
T
IO
N
O F
I.
C
.2 4-
2-
-1 E
T . S
E Q
. A N
D O
T H
E R
L A
W S
CONSULTANTS
PROJECT NAME & ADDRESS
CODE REVIEW STAMP
SHEET NO.
PROJECT MANAGER:
DATE:
CHECKED BY:
DRAWN BY:
REVISIONDATEMARK
02/25/2026
WHW JOB NO.:
25117
A
B
C
D
1 2 3
1 2 3
A
B
C
D
SHEET TITLE
JL
JL
UTNG 6150
HVAC
UPGRADES
17800 1700 W, BLUFFDALE, UT 84065
DD
DFCM#26327480
02/25/2026
MECHANICAL
DETAILS AND
SCHEDULES
ME501
ROOF TOP UNIT SCHEDULE
TAG
AREA SERVED CFM
CFM (OUTSIDE
AIR) ESP
HEATING COOLING ELECTRICAL SEER (3-5 TON)
IEER (7.5+
TON)
OPERATING
WEIGHT MANUF & MODEL SCHEDULE NOTESTYPE # INPUT (BTU/HR)
OUTPUT
(BTU/HR) EAT (DB) EAT (WB)
TOTAL LOAD
(BTU/HR) VOLTAGE PHASE FREQUENCY
# OF
COMPRESSORS MCA MOCP
RTU 1 MEZZANINE 1,600 CFM 320 CFM 0.75 in-wg 53,600 Btu/h 43,200 Btu/h 95 °F 62 °F 44040 Btu/h 208 V 3 60 Hz 1 28 A 40 A 17.2 606 lb CARRIER 48GEDM05B2A5-8B1C0 2,3,4,5,6,7,8,9,10,11
RTU 2 OPEN ROOM 2,400 CFM 480 CFM 0.75 in-wg 100,000 Btu/h 82,000 Btu/h 95 °F 62 °F 65790 Btu/h 208 V 3 60 Hz 1 34 A 45 A 12.2 846 lb CARRIER 48GEEM07B2A5-8B1C0 1,2,3,4,5,6,7,8,9,10,11
RTU 3 OPEN ROOM 2,400 CFM 480 CFM 0.75 in-wg 100,000 Btu/h 82,000 Btu/h 95 °F 62 °F 65790 Btu/h 208 V 3 60 Hz 1 34 A 45 A 12.2 846 lb CARRIER 48GEEM07B2A5-8B1C0 1,2,3,4,5,6,7,8,9,10,11
RTU 4 OPEN ROOM 2,400 CFM 480 CFM 0.75 in-wg 100,000 Btu/h 82,000 Btu/h 95 °F 62 °F 65790 Btu/h 208 V 3 60 Hz 1 34 A 45 A 12.2 846 lb CARRIER 48GEEM07B2A5-8B1C0 1,2,3,4,5,6,7,8,9,10,11
RTU 5 OPEN ROOM 2,400 CFM 480 CFM 0.75 in-wg 100,000 Btu/h 82,000 Btu/h 95 °F 62 °F 65790 Btu/h 208 V 3 60 Hz 1 34 A 45 A 12.2 846 lb CARRIER 48GEEM07B2A5-8B1C0 1,2,3,4,5,6,7,8,9,10,11
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
REVIEWED FOR
CODE COMPLIANCE
RIGID INSULATION -
VARIES BY PROJECT
ROOF DECK VARIES BY
PROJECT
6 2
6 2
6 2
SEAM PLATE AND
FASTENERS AT 12" O.C. -
FASTEN INTO STUDS
ROOFING MEMBRANE - VARIES
BY PROJECT
PRESERVATIVE TREATED 2X
FRAMING / SHIMS
FULLY ADHERED MEMBRANE -
RUN MEMBRANE OVER TOP
OF CURB AS SHOWN AND NAIL
OFF AT 6" O.C. ON INSIDE OF
CURB
NOTE: CURB MUST BE
CONSTRUCTED SO TOP IS LEVEL
DUCTED MECHANICAL EQUIPMENT
(EQUIPMENT VARIES) - FASTEN TO SIDE OF
CURB W/ MIN. OF 2 HIGH-DOMED, CAPPED,
GASKETED FASTENERS PER SIDE - NOTE THAT
NON-DUCTED MECHANICAL EQUIPMENT SHALL
USE THE "ELEVATED EQUIPMENT PLATFORM"
DETAIL IN LIEU OF THIS CURB DETAIL
NOTE THAT IF CURB CONSTRUCTION IS EXISTING, THE CONTRACTOR IS
RESPONSIBLE FOR MODIFYING / RAISING THE CURB AS REQUIRED TO ACHIEVE THE
MIN. DIMENSIONS INDICATED (FROM THE FINISHED ROOF SURFACE TO FASTENERS
AND TOP OF CURB) - IN SUCH CASES, LICENSED MECHANICAL & ELECTRICAL
CONTRACTORS MUST PERFORM ALL REQUIRED CHANGES TO MECHANICAL
EQUIPMENT / LINE SETS / ELECTRICAL WIRING & CONNECTIONS ETC.
FLEXIBLE ELECTRICAL LINES ARE TO ENTER BUILDING
THROUGH A GOOSE NECK PIPE - REFER TO GOOSE
NECK PIPE DETAIL - WHERE OTHER PIPES / CONDUITS,
ETC. OCCUR, COORDINATE WITH PIPE / CONDUIT
DETAILS - ELECTRICAL / COMMUNICATIONS CABLING
SHOULD NOT SHARE THIS PENETRATION, BUT SHOULD
HAVE THEIR OWN - POWER SERVICE LINES
PENETRATING THE ROOF SHOULD BE FLASHED WITH
A PREMANUFACTURED BOOT.
TYPICAL NOTE: ALL EXISTING
ELECTRICAL LINES / CONNECTIONS
(AS OCCUR) ARE TO BE REPLACED
WITH NEW
WITH THE EXCEPTION OF RIGHT AT
THE EQUIPMENT LOCATION,
ELECTRICAL LINES AND JUNCTION
BOX'S THAT ARE RUN ABOVE THE
ROOF, AND OR DECK, ARE TO BE
REPLACED AND RE-RUN BENEATH
THE DECK BACK TO THE NEAREST
JUNCTION OR ELECTRICAL BOX - NO
FLEXIBLE ELECTRICAL CONDUIT
WILL BE ALLOWED LOWER THAN 12"
ABOVE THE FINISHED ROOF
SURFACE - ALL ELECTRICAL WORK
MUST BE DONE TO NEC STANDARDS
NOTE THAT WALK PADS ARE TO
BE PROVIDED AT ALL 4 SIDES
IF FINAL INSULATION DEPTH IS
GREATER THAN THE EXISTING
INSULATION DEPTH, PROVIDE
ADDITIONAL NAILERS / SHIMS AS
REQ'D. TO ACHIEVE THE 10"
MINIMUM HEIGHT FROM THE FINAL
ROOFING SURFACE TO THE TOP
OF THE CURB
NOTE: ALL GAPS BETWEEN DUCT & CURB
ARE TO BE FILLED IN WITH INSULATION
THAT IS EQUIVALENT TO THE R-VALUE
OF THE ROOF SYSTEM
OF SERVICEABLE EQUIPMENT
M
IN
(R
O O
F S
U R
F A
C E
T O
F A
S T
E N
E R
S
N A
IL
E
R S
S
H
IM
S
T O
M
AT
C H
IN
S
U L
A T
IO
N
D E
P T
H
M
IN
T O
T O
P O
F C
U R
B
18" MIN.
(CURB TO PENETRATION TYP.)
EQUIPMENT CURB DETAIL
C4ROOFTOP UNIT SEISMIC BRACKET DETAIL
C2
GAS PIPE SUPPORT ON ROOF DETAIL
D2
SCALE: NONE
SCALE: NONE
6"
GENERAL NOTES:
1. 16 GA GALVANIZED STEEL
SEISMIC HOLD DOWN
BRACKETS BY MICROMETL
OR EQUAL.
2. COORDINATE EXACT
DEPTH OF SEISMIC BRACKET
WITH ROOFTOP
MANUFACTURER.
3. PROVIDE A MINIMUM OF 2
BRACKETS PER SIDE.
4. COORDINATE WITH
SPECIFICATIONS SECTION
15074 VIBRATION AND
SEISMIC CONTROLS.
ROOF CURB
ATTACH TO UNIT
(4)#10x1/2* Tek screws
ATTACH TO CURB
(4)#10x1/2* Tek screws
SCALE: NONE
GALVANIZED PIPE CLAMP
GAS PIPE
GALVANIZED STEEL
CHANNEL
RUBBER
SUPPORT
EXPOSED PIPE SHALL BE
PAINTED BLACK - NO BARE
PIPE SHALL BE EXPOSED
TO THE WEATHER.
JOHN M.
LARSEN
No. 12199025
P R
O
FE
SSIONAL ENG
IN
E
E R
S T
A T E O F
U T
A H
A
LL
ID
E
A S
, D E
S
IG
N S
A
R R
A N
G E
M E
N T
S A
N D
P
LA
N S
IN
D
IC
A
T E
D O
R R
E P
R E
S E
N T
E D
B Y
T H
IS
D
R A
W
IN
G A
R E
O W
N E
D B
Y A
N D
T H
E P
R O
P E
R T
Y O
F W
H W
E N
G
IN
E E
R
IN
G
IN
C . A
N D
W E
R E
C R
E A
T E
D , E
V O
LV
E
D , A
N D
D E
V E
LO
P
E D
F O
R U
S E
O N
A N
D
IN
C O
N N
E C
T
IO
N W
IT
H
T H
E S
P E
C
IF
IE
D
P R
O
JE
C T
N
O N
E O
F T
H E
ID
E
A S
D
E S
IG
N
S
A R
R A
N G
E M
E N
T S
O R
P
LA
N S
S H
A
LL
B E
U S
E D
B Y
O R
D
IS
C
LO
S E
D T
O A
N Y
P E
R S
O N
, F
IR
M
O R
C O
R P
O R
A T
IO
N
F O
R A
N Y
P U
R P
O S
E W
H A
T S
O E
V E
R W
IT
H
O U
T W
R
IT
T E
N C
O N
S E
N T
O F
W H
W E
N G
IN
E
E R
IN
G
IN
C
W
R
IT
T E
N D
IM
E
N S
IO
N
S O
N T
H E
S E
D R
A W
IN
G
S S
H A
LL
H
A V
E P
R E
C E
D E
N C
E O
V E
R S
C A
LE
D
IM
E
N S
IO
N
S
C O
N T
R A
C T
O R
S S
H A
LL
V
E R
IF
Y
A N
D B
E R
E S
P O
N S
IB
LE
F O
R A
LL
D
IM
E
N S
IO
N
S A
N D
C O
N D
IT
IO
N S
O N
T H
E J
O B
A N
D T
H
IS
O F
F
IC
E M
U S
T B
E N
O T
IF
IE
D O
F A
N Y
V A
R
IA
T
IO
N F
R O
M T
H E
D
IM
E N
S
IO
N S
A N
D C
O N
D
IT
IO
N
S S
H O
W N
B Y
T H
E S
E D
R A
W
IN
G S
W
A R
N
IN
G : R
E P
R O
D U
C T
IO
N
H E
R E
O F
IS
A
C R
IM
IN
A L
O F
F E
N S
E U
N D
E R
U .S
.C . S
E C
. 5
. U N
A U
T H
O R
IZ
E
D D
IS
C
LO
S
U R
E M
A Y
C O
N S
T
IT
U T
E T
R A
D E
S E
C R
E T
M
IS
A P
P R
O P
R
IA
T
IO
N
IN
V
IO
LA
T
IO
N
O F
I.
C
.2 4-
2-
-1 E
T . S
E Q
. A N
D O
T H
E R
L A
W S
CONSULTANTS
PROJECT NAME & ADDRESS
CODE REVIEW STAMP
SHEET NO.
PROJECT MANAGER:
DATE:
CHECKED BY:
DRAWN BY:
REVISIONDATEMARK
02/25/2026
WHW JOB NO.:
25117
A
B
C
D
1 2 3
1 2 3
A
B
C
D
SHEET TITLE
JL
JL
UTNG 6150
HVAC
UPGRADES
17800 1700 W, BLUFFDALE, UT 84065
DD
DFCM#26327480
02/25/2026
MECHANICAL
DETAILS
ME502
DIVISION OF FACILITIES
CONSTRUCTION AND
MANAGEMENT
REVIEWED FOR
CODE COMPLIANCE
| Sheets |
| G001 - COVER SHEET |
| G002 - SPECIAL INSPECTION AND TESTING FORM |
| G003 - NONSTRUCTURAL COMPONENT CHECKLIST |
| MD101 - MEZZANINE DEMOLITION PLAN |
| MD102 - ROOFTOP DEMOLITION PLAN |
| ME101 - MEZZANINE MECHANICAL PLAN |
| ME102 - ROOFTOP MECHANICAL PLAN |
| ME501 - MECHANICAL DETAILS AND SCHEDULES |
| ME502 - MECHANICAL DETAILS |
| MG001 - MECHANICAL LEGEND AND GENERAL NOTES |