16-11 - Plans.pdf

PDF 8 MB Posted

Attached to
LLELA Kayak Launch
Solicitation number
26-73-C
Issued by
Denton County, Little Cypress CDP, Texas

About this file

This is a civil engineering site development plan for the LLELA Kayak Launch project located at Lewisville Lake Spillway in Lewisville, Texas, prepared by CEI Engineering Associates, Inc. The project encompasses comprehensive construction of a new kayak and canoe launch facility with associated site improvements on approximately 1.4 acres (61,000 square feet). The scope of work includes demolition and removal of existing structures, utilities, and improvements; site grading with a net cut of 66.56 cubic yards; installation of erosion and sediment control measures; tree preservation and mitigation requiring removal of 104 inches of caliper trees offset by planting of 51 two-inch caliper replacement trees at a 3:1 mitigation ratio; concrete pavement and sidewalk construction; ADA-compliant parking with 38 spaces including four accessible spaces; launch surface installation using CrossGrip non-slip PVC matting and HydroTurf ramp systems; gravel road and parking area improvements; steel pipe fencing and gates; signage; and related site improvements. The project encompasses tree protection measures, wetland construction mat installation for the 1,390 square feet of proposed disturbance (within the 4,356 square feet maximum allowed), and stormwater pollution prevention measures. Plans indicate benchmark elevations using NAVD88 datum and detailed spot elevations throughout the site ranging from approximately 447 feet to 468 feet.

The construction documents include detailed specifications referencing Texas Standard Specifications for Construction and Maintenance of Highways, Streets, and Bridges, and compliance with City of Lewisville standards for concrete paving, sidewalks, and tree preservation. The contractor assumes full responsibility for site conditions, safety, removal and disposal of demolition materials in accordance with local, state, and federal regulations, utility relocation, and property damage prevention. All construction must comply with wetlands regulations enforced by the U.S. Army Corps of Engineers and TCEQ, with coordination required through Ranger Chandler Sanford at USACE Lewisville office. The project includes resident engineering services on a time and frequency basis acceptable to the City Engineer for improvements to public infrastructure, with certification of construction compliance required upon completion. Contractor maintenance obligations include one year of landscape maintenance following Certificate of Occupancy issuance. The planning documents reference a subsurface exploration report prepared by Building & Earth Sciences, Inc. (Report DF250133, dated 11/4/2025) that contractors must verify prior to construction. Property is located within FEMA Flood Insurance Zone A outside the 0.2% annual chance 100-year floodplain per FEMA Map 48121C0555G (revised 04-18-2011).

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GENERAL NOTES: PLAN INDEX:

ASSOCIATED PLANS:

RESOURCE LIST:

A. TOPOGRAPHIC BOUNDARY SURVEY, INCLUDING PROPERTY LINES, LEGAL DESCRIPTION,

EXISTING UTILITIES, SITE TOPOGRAPHY WITH SPOT ELEVATIONS, OUTSTANDING PHYSICAL

FEATURES AND EXISTING STRUCTURE LOCATIONS WAS PROVIDED BY THE FOLLOWING

COMPANY, AS A CONTRACTOR TO THE SELLER/OWNER:

TOPOGRAPHY: CEI ENGINEERING ASSOCIATES, INC.

3030 LYNDON B JOHNSON FWY #920

DALLAS, TX 75234

(972) 488-3737

B. ALL PHASES OF SITE WORK FOR THIS PROJECT SHALL MEET OR EXCEED THE OWNER /

DEVELOPER SITE WORK SPECIFICATIONS.

C. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF EXISTING STRUCTURES,

RELATED UTILITIES, PAVING, UNDERGROUND STORAGE TANKS AND ANY OTHER EXISTING

IMPROVEMENTS AS NOTED. SEE SITE WORK SPECIFICATIONS.

D. CONTRACTOR IS TO REMOVE AND DISPOSE OF ALL DEBRIS, RUBBISH AND OTHER

MATERIALS RESULTING FROM PREVIOUS AND CURRENT DEMOLITION OPERATIONS.

DISPOSAL WILL BE IN ACCORDANCE WITH ALL LOCAL, STATE AND/OR FEDERAL

REGULATIONS GOVERNING SUCH OPERATIONS.

E. THE GENERAL CONTRACTOR WILL BE HELD SOLELY RESPONSIBLE FOR AND SHALL TAKE ALL

PRECAUTIONS NECESSARY TO AVOID PROPERTY DAMAGE TO ADJACENT PROPERTIES

DURING THE CONSTRUCTION PHASES OF THIS PROJECT.

F. WARRANTY/DISCLAIMER: THE DESIGNS REPRESENTED IN THESE PLANS ARE IN

ACCORDANCE WITH ESTABLISHED PRACTICES OF CIVIL ENGINEERING FOR THE DESIGN

FUNCTIONS AND USES INTENDED BY THE OWNER AT THIS TIME. HOWEVER, NEITHER THE

ENGINEER NOR ITS PERSONNEL CAN OR DO WARRANT THESE DESIGNS OR PLANS AS

CONSTRUCTED EXCEPT IN THE SPECIFIC CASES WHERE THE ENGINEER INSPECTS AND

CONTROLS THE PHYSICAL CONSTRUCTION ON A CONTEMPORANEOUS BASIS AT THE SITE.

G. SAFETY NOTICE TO CONTRACTOR: IN ACCORDANCE WITH GENERALLY ACCEPTED

CONSTRUCTION PRACTICES, THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY

RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND

PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY

CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. ANY CONSTRUCTION

OBSERVATION BY THE ENGINEER OF THE CONTRACTOR'S PERFORMANCE IS NOT INTENDED

TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES, IN, ON

OR NEAR THE CONSTRUCTION SITE.

H. ALL CONSTRUCTION IN STATE HIGHWAY DEPARTMENT RIGHT-OF-WAY SHALL BE

COORDINATED WITH THE HIGHWAY DEPARTMENT RESIDENT ENGINEER.

I. WETLANDS NOTE: ANY DEVELOPMENT, EXCAVATION, CONSTRUCTION, OR FILLING IN A U.S.

CORPS OF ENGINEERS DESIGNATED WETLAND IS SUBJECT TO LOCAL, STATE AND FEDERAL

APPROVALS. THE CONTRACTOR SHALL COMPLY WITH ALL PERMIT REQUIREMENTS AND/OR

RESTRICTIONS AND ANY VIOLATION WILL BE SUBJECT TO FEDERAL PENALTY. THE

CONTRACTOR SHALL HOLD THE OWNER/DEVELOPER, THE ENGINEER AND THE LOCAL

GOVERNING AGENCIES HARMLESS AGAINST SUCH VIOLATION. CONTRACTOR TO UTILIZE

THE PLACEMENT OF MATS FOR CONSTRUCTION ACTIVITIES WITHIN WETLANDS OR

MUDFLATS TO MINIMIZE SOIL DISTURBANCE.

J. RESIDENT ENGINEERING SERVICES: WHEN REQUESTED BY THE OWNER, RESIDENT

ENGINEERING SERVICES SHALL BE PROVIDED BY THE ENGINEERS (ON A TIME AND

FREQUENCY BASIS) ACCEPTABLE TO THE CITY ENGINEER FOR IMPROVEMENTS TO PUBLIC

WATER MAINS, PUBLIC SEWER, AND CITY STREETS. AT THE COMPLETION OF

CONSTRUCTION, THE ENGINEER SHALL CERTIFY THE CONSTRUCTION TO BE IN COMPLIANCE

WITH THE PLANS AND SPECIFICATIONS. THIS WORK WILL BE AT THE OWNER/DEVELOPER'S

DIRECT EXPENSE AND SHALL BE COORDINATED WITH CEI ENGINEERING ASSOCIATES, INC. IT

WILL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE RESIDENT ENGINEER OF ANY

PRECONSTRUCTION / CONSTRUCTION CONFERENCES AND ANY PUBLIC CONSTRUCTION 24

HOURS PRIOR TO SAID ACTION.

C0.0 COVER SHEET

C1.0 DEMOLITION PLAN

C2.0 TREE PRESERVATION PLAN

C2.1 TREE PRESERVATION NOTES & DETAILS

C2.2 TREE MITIGATION PLAN

C2.3 TREE MITIGATION NOTES & DETAILS

C3.0 OVERALL SITE PLAN

C3.1 SITE PLAN

C4.0 GRADING PLAN

C5.0 PLAN & PROFILE - WATER ACCESS RAMP

C6.0 EROSION CONTROL PLAN

C6.1 EROSION CONTROL NOTES & DETAILS

C7.0 DETAIL SHEET 1

C7.1 DETAIL SHEET 2

TCEQ

12100 PARK 35 CIRCLE

AUSTIN, TX 78753

PHONE: (512) 239-1000

EMAIL: INFO@TCEQ.TEXAS.GOV

USACE

RANGER CHANDLER SANFORD

1801 N. MILL ST

LEWISVILLE, TX 75057

PHONE: (469) 645-9100

EMAIL: CHANDLER.R.SANFORD@

USACE.ARMY.MIL

CITY OF LEWISVILLE

1197 W. MAIN ST.

LEWISVILLE, TX 75029

PHONE: (972) 219-3400

INTEGRATED ENVIRONMENTAL

SOLUTIONS, LLC

RUDI REINECKE

301 W ELDORADO PKWY, STE. 101

MCKINNEY, TX 75069

(972) 562-7672

RREINECKE@INTENVSOL.COM

1. SURVEY

FLOOD CERTIFICATION:

BY SCALED MAP LOCATION AND GRAPHICAL PLOTTING ONLY. THIS PROPERTY IS DETERMINED TO

BE LOCATED WITHIN ZONE 'A', OR AREAS OUTSIDE THE 0.2% ANNUAL CHANCE 100-YR

FLOODPLAIN AS DETERMINED BY THE NATIONAL FLOOD INSURANCE PROGRAM.

FLOOD INSURANCE MAP FOR DENTON COUNTY, TEXAS.

MAP NUMBER: 48121C0555G

MAP REVISED: 04-18-2011

CEI CONTACT:

NAME: CLIF RODGERS

EMAIL: CLIF.RODGERS@CEIENG.COM

PHONE: (479) 273-9472

CLIENT CONTACT:

NAME: CHRIS CHASTAIN

EMAIL: CCHASTAIN@CITYOFLEWISVILLE.COM

PHONE: (469) 635-5487

Know what's below.

before you dig.Call

CEI ENGINEERING ASSOCIATES, INC.

CEI PROJECT NUMBER

DATE

PROFESSIONAL OF RECORD

PROJECT MANAGER

DESIGNER

REVISION

PRELIMINARY

NOT FOR

CONSTRUCTION

SHEET NUMBER

SHEET TITLE

SITE DEVELOPMENT PLANS

CIVIL ENGINEERING ▪ LANDSCAPE ARCHITECTURE ▪ LAND SURVEYING ▪ PLANNING

3030 LYNDON B JOHNSON FWY #920

DALLAS, TX 75234

PHONE: (972) 488-3737

C0.0

COVER SHEET

REV-1

12/18/2025

33855

WCM

MCR

KAP

LL

EL

A

KA

YA

K

LA

U

N

CH

LE

W

IS

VI

LL

E

LA

KE

LE

W

IS

VI

LL

E

LA

KE

S

PI

LL

W

AY

, E

JO

N

ES

S

T

LE

W

IS

VI

LL

E, T

X

BENTONVILLE | DALLAS | FRESNO | HOUSTON | JACKSONVILLE | MINNEAPOLIS | PHILADELPHIA | PHOENIX

LLELA KAYAK LAUNCH

LEWISVILLE LAKE

LEWISVILLE LAKE SPILLWAY, E JONES ST

LEWISVILLE, TX 75057

DR

AW

IN

G

L O

CA

TI

O N

P:

\3

\3

.1 \D

RA

W

IN

G

S\

DE

SI

G

N \W

O

RK

IN

G

\3

.1

-C S.

DW

G

S

AV

ED

B Y

- W M

AL

LI

CO

TE

© 2025 CEI ENGINEERING ASSOCIATES, INC.

LLELA NATURE

PRESERVE

JONES ST

E STATE HIGHWAY 121E MAIN ST

LEWISVILLE LAKE

ELM

FORK TRINITY RIVER

E COLLEGE ST

FISH HATCHERY RD

SITE

AppƌŽǀĞd fŽƌ CŽnstƌƵĐtiŽn

CITY DEPARTMENT DATE SIGNATURE

PLANNING AND ZONING

ENGINEERING

BUILDING INSPECTION

FIRE PREVENTION

PUBLIC SERVICES

ADA

PARKS

AppƌŽǀĞd fŽƌ CŽnstƌƵĐtiŽn

UTILITY COMPANY DATE SIGNATURE

ELECTRIC

GAS (IF APPLICABLE)

TELECOMMUNICATIONS

CABLE

SOLID WASTE

VICINITY MAP

NOT TO SCALE

BM - 3

MAGNAIL W/WASHER

"CEI CONTROL POINT"

N: 7,075,066.13' E: 2,438,724.29'

Elev.= 466.72'

T eo g 457.34

18 18

GUARDRAIL

E. JONES STREET / CORPS OF ENGINEERS ROAD

ASPHALT PARKIN

G AREA

OHE

OHE

OHE

OHE

OHE

OHE

OHE

OHE

EDGE OF WATER

trash warn trail descr

LAKE LEW

ISVILLE SPILLW

AY

WETLAND AREA PER

UPDATED IES (INTEGRATED

ENVIRONMENTAL

SOLUTIONS) ASSESSMENT -

FILE REFERENCE 04.354.211

DATED 10/17/2025

FLOODWAY PER UPDATED

IES (INTEGRATED

ENVIRONMENTAL

SOLUTIONS) ASSESSMENT -

FILE REFERENCE 04.354.211

DATED 10/17/2025

EXISTING GRAVEL

ROAD TO BE REBUILT18B

51D

EXISTING PIEZOMETER

TO REMAIN19A

EXISTING 46" DEAD

TREE TO BE REMOVED18A

EXISTING GRAVEL PARKING

LOT TO BE REBUILT

18B 51D

EXISTING 6" TREE TO

BE REMOVED18A

EXISTING GRAVEL

ROAD TO BE REBUILT18B

51D

EXISTING GRAVEL

PARKING LOT TO BE

REBUILT

18B 51D

EXISTING GATE POSTS

TO BE REMOVED18A

51D

EXISTING GATE POSTS

TO BE REMOVED18A

51D

EXISTING TRAIL DESCRIPTION

SIGN TO BE RELOCATED18B

51D

EXISTING TRASH WARNING

SIGN TO BE RELOCATED18B

51D

EXISTING FENCING

TO BE REMOVED18A

51D

EXISTING 18" DEAD

TREE TO BE REMOVED18A

EXISTING GATE POSTS

TO BE REMOVED 18A

51D

EXISTING TREES NOT

INCLUDED IN SURVEY

TO BE REMOVED

18A 51D

51D

EXISTING STEEL FENCE

TO BE REMOVED 18A

51D

EXISTING FENCING

TO BE REMOVED18A

51D

EXISTING TREE TO

REMAIN (TYP.) 19A

51D

EXISTING BOLLARDS

TO REMAIN 19A

51D

CONNECT TO

EXISTING ROAD 51B

EXISTING SIGN

TO REMAIN 19A

EXISTING GRAVEL

ROAD TO REMAIN 19A

EXISTING SIGN POST

TO BE REMOVED18A

51D

74A

74A

74A

74A

74A

74A

74A

74A

74A

74A

74A

74A

74A

EXISTING 14" TREE TO

BE REMOVED18A

51D

EXISTING 10" TREE TO

BE REMOVED 18A

51D

51D

EXISTING POWER

POLE TO REMAIN 19A

51D

EXISTING TELEPHONE

BOX TO REMAIN19A

51D

GENERAL DEMOLITION NOTES

A. THE SITE WORK FOR THIS PROJECT SHALL MEET OR EXCEED THE "TEXAS STANDARD SPECIFICATIONS FOR

CONSTRUCTION AND MAINTENANCE OF HIGHWAYS, STREETS, AND BRIDGES".

B. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL OF THE EXISTING STRUCTURES, RELATED UTILITIES, PAVING, UNDERGROUND STORAGE TANKS AND ANY OTHER EXISTING IMPROVEMENTS AS NOTED. SEE SITE WORK

SPECIFICATIONS.

C. CONTRACTOR IS TO REMOVE AND DISPOSE OF ALL DEBRIS, RUBBISH AND OTHER MATERIALS RESULTING FROM PREVIOUS AND CURRENT DEMOLITION OPERATIONS. DISPOSAL WILL BE IN ACCORDANCE WITH ALL LOCAL, STATE

AND/OR FEDERAL REGULATIONS GOVERNING SUCH OPERATIONS.

D. THE GENERAL CONTRACTOR SHALL TAKE ALL PRECAUTIONS NECESSARY TO AVOID PROPERTY DAMAGE TO ADJACENT PROPERTIES DURING THE CONSTRUCTION PHASES OF THIS PROJECT. THE CONTRACTOR WILL BE HELD SOLELY RESPONSIBLE FOR ANY DAMAGES TO THE ADJACENT PROPERTIES OCCURRING DURING THE CONSTRUCTION PHASES

OF THIS PROJECT.

E. ENGINEER'S NOTICE TO CONTRACTOR

THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE.

THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANY AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS.

SCALE IN FEET

60'45'30'0

Know what's below.

before you dig.Call

CEI ENGINEERING ASSOCIATES, INC.

CEI PROJECT NUMBER

DATE

PROFESSIONAL OF RECORD

PROJECT MANAGER

DESIGNER

REVISION

PRELIMINARY

NOT FOR

CONSTRUCTION

SHEET NUMBER

SHEET TITLE

3030 LYNDON B JOHNSON FWY #920

DALLAS, TX 75234

PHONE: (972) 488-3737

FAX: ----

C1.0

DEMOLITION PLAN

REV-1

11/19/2025

33855

WCM

MCR

KAP

LL

EL

A

KA

YA

K

LA

U

N

CH

LE

W

IS

VI

LL

E

LA

KE

LE

W

IS

VI

LL

E

LA

KE

S

PI

LL

W

AY

, E

JO

N

ES

S

T

LE

W

IS

VI

LL

E, T

X

DR

AW

IN

G

L O

CA

TI

O N

P:

\3

\3

.1 \D

RA

W

IN

G

S\

DE

SI

G

N \W

O

RK

IN

G

\3

.1

-S P.

DW

G

S

AV

ED

B Y

- W M

AL

LI

CO

TE

© 2025 CEI ENGINEERING ASSOCIATES, INC.

SITE BENCHMARK

BENCHMARK #1: A 5/8" REBAR WITH YELLOW CAP STAMPED "CEI

CONTROL" APPROXIMATELY 214' EAST OF A METAL FENCE POST.

ELEV= 466.72' NAVD88

N: 7,075,066.13 E: 2,438,724.29

BENCHMARK #2: A 5/8" REBAR WITH YELLOW CAP STAMPED "CEI

CONTROL" APPROXIMATELY 260' SOUTHEAST OF A METAL FENCE POST.

ELEV= 448.40' NAVD88

N:7,074,353.70

E: 32,438,944.83

BENCHMARK #3: A MAGNAIL WITH WASHER STAMPED "CEI CONTROL"

APPROXIMATELY 73' NORTHWEST OF TRAIL DESCRIPTION SIGN.

ELEV= 448.40' NAVD88

N:7,074,353.70

E: 32,438,944.83

DEMOLITION NOTES

18A EXISTING TO BE REMOVED.

18B EXISTING TO BE RELOCATED.

19A EXISTING TO REMAIN.

51B LIMITS OF PAVEMENT REMOVAL

51D PROTECT EXISTING STRUCTURES AND/OR PIPES DURING DEMOLITION AND

CONSTRUCTION PHASES.

74A REFERENCE TREE PRESERVATION PLAN FOR ALL POTENTIAL ON-SITE TREE IMPACTS

EXISTING LEGEND

(Size)

T

Gas Line Underground Fiber Optic Line

Overhead Electric Line Sanitary Sewer Line

Storm Drainage Pipe

Underground Telephone Line

Water Line

Benchmark (BM)

Found Monument (As Noted)

Set 5/8" Rebar "LS#XXXX"

Electric Meter Guy Wire / Anchor

Utility Pole

Telephone Riser

Traffic Sign (Type of Sign)

GAS

FOC

OHE

SS

UGT

W

Break Line

Flow Line

Metal Fence Line

Standpipe

Bollard / Guard Post

Tree (Deciduous)

Tree (Evergreen)

(Size)

(Size)

Control Line

Edge of Gravel

Floodplain Area

Wetland Boundary Floodway Boundary

"CEI CONTROL POINT"

N: 7,075,066.13' E: 2,438,724.29'

Elev.= 466.72'

T eo g 457.34

18 18

E. JONES STREET / CORPS OF ENGINEERS ROAD

2 451

447 44

448449

OHE

OHE

OHE

OHE

OHE

OHE

OHE

OHE

EDGE OF WATER

trash warn trail descr

460459

LAKE LEW

ISVILLE SPILLW

AY

100-YR FLOODPLAIN PER

FEMA MAP 48121C0555G

100-YR FLOODPLAIN PER FEMA MAP 48121C0555G

100-YR FLOODPLAIN PER

FEMA MAP 48121C0555G

100-YR FLOODPLAIN PER

FEMA MAP 48121C0555G

WETLAND AREA PER

UPDATED IES (INTEGRATED

ENVIRONMENTAL

SOLUTIONS) ASSESSMENT -

FILE REFERENCE 04.354.211

DATED 10/17/2025

REMOVE EXISTING 6"

DBH DECIDUOUS TREE77A

77B

77B

X

X

X

X

TYP. 50H

90A

REMOVE EXISTING DEAD

46" DBH TREE

REMOVE EXISTING DEAD

18" DBH TREE

PROTECT EXISTING 18" SYCAMORE

AND 6" OAK TREES

DEC

DEC

DEC

DEC

DEC

DEC

DEC

DEC

DEC

OAK

DEC

OAK

OAK

OAK

DEC

DEC

DEC

DEC

DEC

DEC

DEC

DEC

EVG 24

DEC

CLEAR ALL UNSURVEYED

PLANT MATERIAL77E

77D

77D

77D

77D

DEAD

DEC

DEAD

REMOVE EXISTING (2)

10" & (1) 14" DBH

DECIDUOUS TREE

77A

CLEAR ALL UNPROTECTED

& UNSURVEYED

PLANT MATERIAL

77E

X

X X

X

X

X

X

X

X

X

X

X

X

X

X

CEI ENGINEERING ASSOCIATES, INC.

CEI PROJECT NUMBER

DATE

PROFESSIONAL OF RECORD

PROJECT MANAGER

DESIGNER

REVISION

PRELIMINARY

NOT FOR

CONSTRUCTION

SHEET NUMBER

SHEET TITLE

3030 LYNDON B JOHNSON FWY #920

DALLAS, TX 75234

PHONE: (972) 488-3737

FAX: ----

C2.0

TREE PRESERVATION

PLAN

REV-1

12/18/2025

33855

WCM

MCR

KAP

LL

EL

A

KA

YA

K

LA

U

N

CH

LE

W

IS

VI

LL

E

LA

KE

LE

W

IS

VI

LL

E

LA

KE

S

PI

LL

W

AY

, E

JO

N

ES

S

T

LE

W

IS

VI

LL

E, T

X

DR

AW

IN

G

L O

CA

TI

O N

P:

\3

\3

.1 \D

RA

W

IN

G

S\

DE

SI

G

N \W

O

RK

IN

G

\3

.1

-T P.

DW

G

S

AV

ED

B Y

- W M

AL

LI

CO

TE

© 2025 CEI ENGINEERING ASSOCIATES, INC.

SCALE IN FEET

60'45'30'0

Know what's below.

before you dig.Call

SITE BENCHMARK

BENCHMARK #1: A 5/8" REBAR WITH YELLOW CAP STAMPED "CEI

CONTROL" APPROXIMATELY 214' EAST OF A METAL FENCE POST.

ELEV= 466.72' NAVD88

N: 7,075,066.13 E: 2,438,724.29

BENCHMARK #2: A 5/8" REBAR WITH YELLOW CAP STAMPED "CEI

CONTROL" APPROXIMATELY 260' SOUTHEAST OF A METAL FENCE POST.

ELEV= 448.40' NAVD88

N:7,074,353.70

E: 32,438,944.83

BENCHMARK #3: A MAGNAIL WITH WASHER STAMPED "CEI CONTROL"

APPROXIMATELY 73' NORTHWEST OF TRAIL DESCRIPTION SIGN.

ELEV= 448.40' NAVD88

N:7,074,353.70

E: 32,438,944.83

TREE PRESERVATION PLAN NOTES

1. ALL TREES AND NATURAL AREAS SHOWN ON THIS PLAN TO BE PRESERVED SHALL BE PROTECTED DURING

CONSTRUCTION WITH TEMPORARY FENCING.

2. PROTECTIVE FENCES SHALL BE ERECTED ACCORDING TO CITY OF LEWISVILLE STANDARDS FOR TREE

PROTECTION.

3. PROTECTIVE FENCES SHALL BE INSTALLED PRIOR TO THE START OF ANY SITE PREPARATION WORK AND SHALL

BE MAINTAINED THROUGHOUT ALL PHASES OF THE CONSTRUCTION PROJECT.

4. EROSION AND SEDIMENTATION CONTROL BARRIERS SHALL BE INSTALLED OR MAINTAINED IN A MANNER

WHICH DOES NOT RESULT IN SOIL BUILD-UP WITHIN TREE DRIPLINES.

5. PROTECTIVE FENCES SHALL SURROUND THE TREE OR GROUP OF TREES AND WILL BE LOCATED AT THE

DRIPLINE. FOR NATURAL AREAS, PROTECTIVE FENCES SHALL FOLLOW THE LIMIT ON CONSTRUCTION IN ORDER

TO PREVENT THE FOLLOWING:

A.) SOIL COMPACTION IN THE ROOT ZONE RESULTING FROM VEHICULAR TRAFFIC OR STORAGE OF

EQUIPMENT.

B.) ROOT ZONE DISTURBANCES DUE TO GRADE CHANGES (GREATER THAN 6 ") ROOT TRENCHING NOT

VIEWED BY CITY ARBORISTS.

C.) WOUNDS TO EXPOSED ROOTS, TRUNK OR LIMBS BY MECHANICAL EQUIPMENT.

D.) OTHER ACTIVITIES DETRIMENTAL TO TREES SUCH AS CHEMICAL STORAGE, CONCRETE TRUCK

CLEANING AND FIRES.

6. EXCEPTIONS TO INSTALLING FENCES AT TREE DRIPLINES MAY BE PERMITTED IN THE FOLLOWING CASES, A.) WHERE THERE IS TO BE AN APPROVE GRADE CHANGE, IMPERMEABLE PAVING SURFACE, TREE WELL, OR

OTHER SUCH SITE DEVELOPMENT.

B.) WHERE PERMEABLE PAVING IS TO BE INSTALLED WITHIN A TREE'S DRIPLINE, ERECT THE FENCE AT THE OUTER LIMITS OF THE PERMEABLE PAVING AREA (PRIOR TO SITE GRADING SO THIS AREA IS GRADED

SEPARATELY PRIOR TO PAVING INSTALLATION TO MINIMIZE ROOT DAMAGE)

7. WHERE ANY OF THE ABOVE EXCEPTIONS RESULT IN A FENCE BEING CLOSER THAN 4 FEET TO A TRUNK, PROTECT THE TRUNK WITH STRAPPED ON PLANKING TO HEIGHT OF 8 FEET (OR LIMITS OF LOWER

BRANCHING) IN ADDITION TO THE REDUCED FENCING PROVIDED.

8. TREES APPROVED FOR REMOVAL SHALL BE REMOVED IN A MANNER WHICH DOES NOT IMPACT TREES TO BE

PRESERVED.

9. ANY ROOTS EXPOSED BY CONSTRUCTION ACTIVITY SHALL BE PRUNED FLUSH WITH THE SOIL. BACKFILL ROOT AREAS WITH GOOD QUALITY TOPSOIL AS SOON AS POSSIBLE. IF EXPOSED ROOT AREAS ARE NOT BACKFILLED WITHIN 2 DAYS, COVER WITH ORGANIC MATERIAL IN A MANNER WHICH REDUCES SOIL

TEMPERATURE AND MINIMIZES WATER LOSS DUE TO EVAPORATION.

10. ANY TRENCHING REQUIRED SHALL BE PLACED AS FAR FROM EXISTING TREE TRUNKS AS POSSIBLE.

11. NO LANDSCAPE TOPSOIL DRESSING GREATER THAN 4 INCHES SHALL BE PERMITTED WITHIN THE DRIPLINE OF

TREES. NO SOIL IS PERMITTED ON THE ROOT FLARE OF ANY TREE.

12. PRUNING TO PROVIDE CLEARANCE FOR STRUCTURES, VEHICULAR TRAFFIC, AND EQUIPMENT SHALL TAKE

PLACE BEFORE CONSTRUCTION BEGINS.

13. ALL FINISHED PRUNING MUST BE DONE ACCORDING TO RECOGNIZED, APPROVED STANDARDS OF THE

INDUSTRY (REFERENCE THE AMERICAN NATIONAL STANDARD, ANSI-A3OO PRUNING, OR LATER CITY CERTIFIED

TREE PRUNER MUST BE RETAINED TO MAKE ALL PRUNING CUTS.

14. DEVIATIONS FROM THE ABOVE NOTES MAY BE CONSIDERED ORDINANCE VIOLATIONS IF THERE IS

SUBSTANTIAL NON-COMPLIANCE OR IF A TREE SUSTAINS DAMAGE AS A RESULT.

PROPOSED LEGEND

TREE PROTECTION AREA

TREE PROTECTION FENCEX X

EXISTING TREE TO BE REMOVED

EXISTING TREE TO BE PRESERVED

AND PROTECTED

EDGE OF WOODED AREA

18"

18"

TREE PROTECTION NOTES

77A EXISTING TREE TO BE REMOVED, INCLUDING STUMP AND ROOTS.

77B EXISTING TREE TO BE REMOVED, STUMP TO BE CUT FLUSH WITH FINISHED GRADE AND LEFT

IN PLACE.

77D AREA TO REMAIN UNDISTURBED.

77E EXISTING PLANT MATERIAL TO BE CUT AND CLEARED INCLUDING ALL STUMPS AND ROOTS

TREE PROTECTION DETAILS

50H TREE PROTECTION DETAIL

90A SOIL COMPACTION PREVENTION DETAIL

GENERAL TREE PRUNING NOTES

1. TREES PRUNING SHALL BE PERFORMED BY A QUALIFIED TREE CARE PROFESSIONAL UNDER THE SUPERVISION

OF A CERTIFIED ARBORIST AND IN COORDINATION WITH THE LANDSCAPE ARCHITECT.

2. TREES SHALL NOT BE "TOPPED".

3. NO MORE THAN 20% OF THE LIVING TREE CANOPY SHALL BE REMOVED IN ONE GROWING SEASON.

4. PRUNING SHALL BE DONE DURING LATE WINTER WHEN THE TREES DORMANT SEASON OR IN MID SUMMER

ONCE THE LEAVES HAVE REACHED THEIR FULL SIZE. ONLY LIGHT PRUNING (LESS THAN 10% OF THE FOLIAGE)

SHALL BE DONE OTHER TIMES OF THE YEAR.

5. TREES SHALL NOT BE PRUNED DURING TIMES OF EXTENDED DROUGHT OR IF THE TREE IS UNDER STRESS.

6. DEAD OR DAMAGED WOOD CAN BE REMOVED AT ANY TIME, AS NEEDED.

7. LIMBS SHALL BE PRUNED TO A MINIMUM OF 7' ABOVE WALKWAYS AND 8' ABOVE VEHICULAR AREAS.

TREE PRESERVATION LIST

NUMBER SPECIES SIZE HEALTH PROTECTED

1 DECIDUOUS 16" GOOD YES

2 DECIDUOUS 10" GOOD YES

3 DECIDUOUS 8" GOOD YES

4 DECIDUOUS 14" GOOD YES

5 DECIDUOUS 8" GOOD YES

6 DECIDUOUS 6" GOOD NO

7 DECIDUOUS 6" GOOD NO

8 DECIDUOUS 10" GOOD YES

9 DECIDUOUS 10" GOOD YES

10 POST OAK 8" GOOD YES

11 DECIDUOUS 8" GOOD YES

12 POST OAK 8" GOOD YES

13 POST OAK 8" GOOD YES

14 POST OAK 8" GOOD YES

15 DECIDUOUS 16" GOOD YES

16 DECIDUOUS 6" GOOD NO

17 DECIDUOUS 6" GOOD NO

18 DECIDUOUS 14" GOOD NO

19 DECIDUOUS 10" GOOD NO

20 DECIDUOUS 10" GOOD NO

21 DECIDUOUS 10" GOOD YES

22 DECIDUOUS 6" GOOD NO

23 EVERGREEN 18" FAIR YES

24 DECIDUOUS 18" GOOD YES

25 DEAD 46" DEAD NO

26 DECIDUOUS 6" FAIR NO

27 DEAD 18" DEAD NO

EXISTING LEGEND

(Size)

T

Gas Line Underground Fiber Optic Line

Overhead Electric Line Sanitary Sewer Line

Storm Drainage Pipe

Underground Telephone Line

Water Line

Benchmark (BM)

Found Monument (As Noted)

Set 5/8" Rebar "LS#XXXX"

Electric Meter Guy Wire / Anchor

Utility Pole

Telephone Riser

Traffic Sign (Type of Sign)

GAS

FOC

OHE

SS

UGT

W

Break Line

Flow Line

Metal Fence Line

Standpipe

Bollard / Guard Post

Tree (Deciduous)

Tree (Evergreen)

(Size)

(Size)

Control Line

Edge of Gravel

CITY TREE PRESERVATION REQUIREMENTS

REQUIREMENT

PROTECTED

TREES

SURVEYED PROVIDED

HEALTHY TREES THAT ARE 8" DBH CALIPER & LARGER (16) PROTECTED;

(11)

UNPROTECTED

6 UNPROTECTED

TREES REMOVED

(4 LIVE; 2 DEAD)

PRESERVATION

CREDITS

POST OAKS & BLACKJACK OAKS LESS THAN 8" DBH CALIPER

+1" FOR EVERY 1" PRESERVED

PROTECTED POST OAKS AND BLACKJACK OAKS

+2" FOR EVERY 1" PRESERVED

ALL OTHER PROTECTED TREES

+1" FOR EVERY 1" PRESERVED

(4) 8" POST OAKS

(16) PROTECTED

TREES - VARIOUS

SIZES

208"

PRESERVATION

CREDIT

Floodplain Area

Wetland Boundary Floodway Boundary

TREE PRESERVATION TOTALS

SPECIES CALIPER SIZE TREE TOTAL HEALTH

PRESERVED 208" 21 GOOD

REMOVED 40" 4 GOOD

REMOVED 64" 2 DEAD

CEI ENGINEERING ASSOCIATES, INC.

CEI PROJECT NUMBER

DATE

PROFESSIONAL OF RECORD

PROJECT MANAGER

DESIGNER

REVISION

PRELIMINARY

NOT FOR

CONSTRUCTION

SHEET NUMBER

SHEET TITLE

3030 LYNDON B JOHNSON FWY #920

DALLAS, TX 75234

PHONE: (972) 488-3737

FAX: ----

C2.1

TREE PRESERVATION

NOTES & DETAILS

REV-1

12/18/2025

33855

WCM

MCR

KAP

LL

EL

A

KA

YA

K

LA

U

N

CH

LE

W

IS

VI

LL

E

LA

KE

LE

W

IS

VI

LL

E

LA

KE

S

PI

LL

W

AY

, E

JO

N

ES

S

T

LE

W

IS

VI

LL

E, T

X

DR

AW

IN

G

L O

CA

TI

O N

P:

\3

\3

.1 \D

RA

W

IN

G

S\

DE

SI

G

N \W

O

RK

IN

G

\3

.1

-T P.

DW

G

S

AV

ED

B Y

- W M

AL

LI

CO

TE

© 2025 CEI ENGINEERING ASSOCIATES, INC.

50H

TREE PROTECTION

N.T.S.

TREE

PROTECTION

AREA

KEEP OUT

CRITICAL ROOT ZONE/LIMITS OF CROWN DRIP LINE.

SEE TREE PRESERVATION PLAN FOR FENCE LOCATIONS

5' TYP.

TREE PROTECTION FENCE. HIGH DENSITY POLYETHYLENE

FENCING WITH 3.5" X 1.5" OPENINGS. COLOR: ORANGE.

ATTACH PER MANUFACTURES SPECS

6' STEEL T-POSTS OR APPROVED EQUAL. INSTALL AT 8' O.C.

MIN 8" THICK LAYER OF ORGANIC BARK OR SHREDDED

HARDWOOD MULCH, MULCH SHALL BE PLACED AND SPREAD

IN THIS AREA USING HAND TOOLS AND WHEELBARROWS

MAINTAIN EXISTING GRADE WITH THE TREE PROTECTION FENCE

UNLESS OTHERWISE INDICATED ON THE GRADING PLAN

11" X 17" SIGN LAMINATED IN PLASTIC AND SPACED EVERY 50'

ALONG THE FENCE (IF REQUIRED)

PROVIDE CLEAR AREA AT TRUNK

DO NOT PILE MULCH AGAINST TRUNK

90A

SOIL COMPACTION PREVENTION DETAIL

N.T.S.

STRUCTURAL ROOT ZONE

1/2 TRUNK DIA IN INCHES =

STRUCTURAL ROOT ZONE

RADIUS IN FEET

TREE PROTECTION FENCE (SEE DETAIL 50H)

SEE TREE PROTECTION OR DEMOLITION

PLANS FOR FENCE LOCATION

MIN 8" THICK LAYER OF ORGANIC BARK

OR SHREDDED HARDWOOD MULCH, MULCH

MAY NEED TO BE REPLENISHED DUE TO

RAIN OR SINKING INTO SOIL

3/4" PLYWOOD, REPLACE BROKEN

PLYWOOD WHEN NECESSARY TO MAINTAIN

SOLID COVERAGE

NO DISTURBANCE SHALL BE ALLOWED

WITHIN STRUCTURAL ROOT ZONE

T

E. JONES STREET / CORPS OF ENGINEERS ROAD

2 451

447 44

447448449

OHE

OHE

OHE

OHE

OHE

OHE

EDGE OF WATER

LAKE LEW

ISVILLE SPILLW

AY

100-YR FLOODPLAIN PER

FEMA MAP 48121C0555G

100-YR FLOODPLAIN PER FEMA MAP 48121C0555G

100-YR FLOODPLAIN PER

FEMA MAP 48121C0555G

100-YR FLOODPLAIN PER

FEMA MAP 48121C0555G

WETLAND AREA PER

UPDATED IES (INTEGRATED

ENVIRONMENTAL

SOLUTIONS) ASSESSMENT -

FILE REFERENCE 04.354.211

DATED 10/17/2025

FLOODWAY PER UPDATED

IES (INTEGRATED

ENVIRONMENTAL

SOLUTIONS) ASSESSMENT -

FILE REFERENCE 04.354.211

DATED 10/17/2025

TYP.50A

CEI ENGINEERING ASSOCIATES, INC.

CEI PROJECT NUMBER

DATE

PROFESSIONAL OF RECORD

PROJECT MANAGER

DESIGNER

REVISION

PRELIMINARY

NOT FOR

CONSTRUCTION

SHEET NUMBER

SHEET TITLE

3030 LYNDON B JOHNSON FWY #920

DALLAS, TX 75234

PHONE: (972) 488-3737

FAX: ----

C2.2

TREE MITIGATION

PLAN

REV-1

12/18/2025

33855

WCM

MCR

KAP

LL

EL

A

KA

YA

K

LA

U

N

CH

LE

W

IS

VI

LL

E

LA

KE

LE

W

IS

VI

LL

E

LA

KE

S

PI

LL

W

AY

, E

JO

N

ES

S

T

LE

W

IS

VI

LL

E, T

X

DR

AW

IN

G

L O

CA

TI

O N

P:

\3

\3

.1 \D

RA

W

IN

G

S\

DE

SI

G

N \W

O

RK

IN

G

\3

.1

-T P.

DW

G

S

AV

ED

B Y

- W M

AL

LI

CO

TE

© 2025 CEI ENGINEERING ASSOCIATES, INC.

SCALE IN FEET

80'60'0 40'

Know what's below.

before you dig.Call

SITE BENCHMARK

BENCHMARK #1: A 5/8" REBAR WITH YELLOW CAP STAMPED "CEI

CONTROL" APPROXIMATELY 214' EAST OF A METAL FENCE POST.

ELEV= 466.72' NAVD88

N: 7,075,066.13 E: 2,438,724.29

BENCHMARK #2: A 5/8" REBAR WITH YELLOW CAP STAMPED "CEI

CONTROL" APPROXIMATELY 260' SOUTHEAST OF A METAL FENCE POST.

ELEV= 448.40' NAVD88

N:7,074,353.70

E: 32,438,944.83

BENCHMARK #3: A MAGNAIL WITH WASHER STAMPED "CEI CONTROL"

APPROXIMATELY 73' NORTHWEST OF TRAIL DESCRIPTION SIGN.

ELEV= 448.40' NAVD88

N:7,074,353.70

E: 32,438,944.83

EXISTING LEGEND

(Size)

T

Gas Line Underground Fiber Optic Line

Overhead Electric Line Sanitary Sewer Line

Storm Drainage Pipe

Underground Telephone Line

Water Line

Benchmark (BM)

Found Monument (As Noted)

Set 5/8" Rebar "LS#XXXX"

Electric Meter Guy Wire / Anchor

Utility Pole

Telephone Riser

Traffic Sign (Type of Sign)

GAS

FOC

OHE

SS

UGT

W

Break Line

Flow Line

Metal Fence Line

Standpipe

Bollard / Guard Post

Tree (Deciduous)

Tree (Evergreen)

(Size)

(Size)

Control Line

Edge of Gravel

Floodplain Area

Wetland Boundary Floodway Boundary

SYMBOL QTY BOTANICAL / COMMON NAME SIZE DETAIL CAL.

TREES

10 CERCIS CANADENSIS / EASTERN REDBUD B&B 50A 2.00" CAL.

10 FRAXINUS ALBICANS / TEXAS ASH B&B 50A 2.00" CAL.

10 PLATANUS OCCIDENTALIS / AMERICAN SYCAMORE B&B 50A 2.00" CAL.

11 QUERCUS MACROCARPA / BURR OAK B&B 50A 2.00" CAL.

10 QUERCUS SHUMARDII / SHUMARD OAK B&B 50A 2.00" CAL.

2025-11-20 14:47

PLANT SCHEDULE

TREE MITIGATION DETAILS

50A TREE PLANTING DETAIL

TREE MITIGATION GENERAL NOTES

A. REFER TO TREE MITIGATION NOTES SHEET FOR NOTES AND DETAILS

TREE MITIGATION CALCULATIONS

TOTAL CALIPER INCHES REMOVED = 34* MITIGATION RATION - 3:1

34 x 3 = 102 MITIGATION INCHES REQUIRED

(51) 2" CALIPER TREES PROPOSED = 102

MITIGATION INCHES PROVIDED

*REFER TO TREE PRESERVATION PLAN

2025-11-20 14:47

DATE

PROFESSIONAL OF RECORD

PROJECT MANAGER

DESIGNER

REVISION

PRELIMINARY

NOT FOR

CONSTRUCTION

SHEET NUMBER

SHEET TITLE

3030 LYNDON B JOHNSON FWY #920

DALLAS, TX 75234

PHONE: (972) 488-3737

FAX: ----

C2.3

TREE MITIGATION

NOTES

REV-1

12/18/2025

33855

WCM

MCR

KAP

LL

EL

A

KA

YA

K

LA

U

N

CH

LE

W

IS

VI

LL

E

LA

KE

LE

W

IS

VI

LL

E

LA

KE

S

PI

LL

W

AY

, E

JO

N

ES

S

T

LE

W

IS

VI

LL

E, T

X

DR

AW

IN

G

L O

CA

TI

O N

P:

\3

\3

.1 \D

RA

W

IN

G

S\

DE

SI

G

N \W

O

RK

IN

G

\3

.1

-T P.

DW

G

S

AV

ED

B Y

- W M

AL

LI

CO

TE

© 2025 CEI ENGINEERING ASSOCIATES, INC.

GENERAL NOTES

1. CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL PROPOSED LANDSCAPING IS INSTALLED IN ACCORDANCE WITH PLANS, DETAILS, SPECIFICATIONS (IF APPLICABLE) AND ALL LOCAL CODES AND

REQUIREMENTS.

2. CONTRACTOR TO INSPECT SITE AND VERIFY CONDITIONS AND DIMENSIONING PRIOR TO PROCEEDING WITH WORK DESCRIBED HERE IN. NOTIFY LANDSCAPE ARCHITECT OF ANY DISCREPANCIES PRIOR TO

BEGINNING ANY CONSTRUCTION.

3. QUANTITIES PROVIDED IN THE PLANT LIST ARE FOR GENERAL USE ONLY. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL PLANT AND LANDSCAPE MATERIAL QUANTITIES. SYMBOL COUNT ON PLAN

TAKES PRECEDENCE OVER TABLE QUANTITIES.

4. IMMEDIATELY AFTER AWARD OF CONTRACT, NOTIFY THE OWNER'S REPRESENTATIVE AND/OR THE LANDSCAPE ARCHITECT OF UNAVAILABILITY OF SPECIFIED PLANT MATERIAL FROM COMMERCIAL

NURSERIES. THE OWNER'S REPRESENTATIVE AND/OR LANDSCAPE ARCHITECT WILL PROVIDE

ALTERNATE PLANT MATERIAL SELECTIONS IF UNAVAILABILITY OCCURS. SUCH CHANGES SHALL NOT

ALTER THE ORIGINAL BID PRICE UNLESS A CREDIT IS DUE TO THE OWNER.

5. ALL PLANT MATERIALS TO CONFORM TO THE AMERICAN STANDARD FOR NURSERY STOCK ANSI Z60.1.

6. CONTAINER GROWN STOCK SHOULD HAVE GROWN IN A CONTAINER LONG ENOUGH FOR THE ROOT

SYSTEM TO HAVE DEVELOPED SUFFICIENTLY TO HOLD ITS SOIL TOGETHER.

7. ANY PLANT SUBSTITUTIONS, RELOCATION, OR REQUIRED CHANGE SHALL REQUIRE THE WRITTEN

APPROVAL OF THE LANDSCAPE ARCHITECT OR OWNER.

8. THE OWNER'S REPRESENTATIVE AND/OR LANDSCAPE ARCHITECT RESERVE THE RIGHT TO REFUSE ANY

MATERIAL THEY DEEM UNACCEPTABLE.

9. COORDINATE WITH PROJECT REPRESENTATIVE FOR DISTURBED SITE TREATMENTS OUTSIDE LANDSCAPE

IMPROVEMENTS. SEE SHEET 6.0 - EROSION CONTROL PLAN.

10. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL

UNDERGROUND UTILITIES AND SHALL AVOID DAMAGE TO ALL UTILITIES DURING THE COURSE OF THE WORK. LOCATIONS OF EXISTING BURIED UTILITY LINES SHOWN ON THE PLANS ARE BASED UPON BEST

AVAILABLE INFORMATION AND ARE TO BE CONSIDERED APPROXIMATE. IT SHALL BE THE

RESPONSIBILITY OF THE CONTRACTOR 1) TO VERIFY THE LOCATIONS OF UTILITY LINES AND ADJACENT TO THE WORK AREA 2) TO PROTECT OF ALL UTILITY LINES DURING THE CONSTRUCTION PERIOD 3) TO REPAIR ANY AND ALL DAMAGE TO UTILITIES, STRUCTURES, SITE APPURTENANCES, ETC. WHICH OCCURS

AS A RESULT OF THE CONSTRUCTION AT NO COST TO THE OWNER.

11. ALL PLANT MATERIAL QUANTITIES SHOWN ARE APPROXIMATE. CONTRACTOR SHALL BE RESPONSIBLE

FOR COMPLETE COVERAGE OF ALL PLANTING BEDS AT SPACING SHOWN.

12. IF A SWPPP PLAN IS PROVIDED THIS PLAN IS TO BE IMPLEMENTED COOPERATIVELY WITH SWPPP PLAN, AS NEEDED, TO MAXIMIZE THE EFFECTIVENESS OF THE SWPPP PLAN FOR THIS SITE.

13. ALL PLANT MATERIAL IN TREE HOLDING AREAS SHALL BE MANUALLY WATERED/IRRIGATED TO KEEP

MOIST UNTIL PLANTED.

14. REFER TO CITY OF LEWISVILLE TREE SPECIES LIST FOR ACCEPTABLE SPECIES SUBSTITUTIONS

1. LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARING ALL PLANTED AREAS. ALL DELETERIOUS MATERIALS SUCH AS ROCK, TRASH, CONSTRUCTION DEBRIS, AGGREGATE BASE MATERIAL, ASPHALT, ETC. SHALL BE REMOVED PRIOR TO ANY FILL OPERATIONS. FILL ALL PLANTING AREAS WITH CLEAN EARTHEN FILL. SOIL SHALL BE FREE OF HEAVY, STIFF CLAY AND ANY DELETERIOUS MATERIAL OVER ONE INCH IN SIZE. THE TOP SIX INCHES OF FILL MATERIAL STRIPPED FROM SITE MAY BE UTILIZED FOR PLANTER OR TOPSOIL FILL IF PRIOR APPROVAL HAS BEEN

OBTAINED FROM THE OWNER'S REPRESENTATIVE AND/OR LANDSCAPE ARCHITECT.

2. TREES PLANTED ADJACENT TO PUBLIC ROADS AND PEDESTRIAN SIDEWALKS SHALL BE PRUNED SUFFICIENTLY TO AVOID VISUAL BLOCKS TO INTERSECTING VEHICULAR ACCESS OR INTERFERENCE WITH PEDESTRIAN WALKWAYS.

TREES WITH A 4" OR LARGER CALIPER SHALL BE PRUNED UP TO 6'-0" ABOVE PAVEMENTS.

3. BACKFILL ALL TREES, SHRUBS, GROUNDCOVER WITH A MIXTURE OF 2 PARTS NATIVE SOIL AND 1 PART SOIL

CONDITIONING WITH WOOD MULCH.

4. THE LANDSCAPE CONTRACTOR SHALL WATER TEST ALL PLANTING HOLE PRIOR TO PLANTING. IF HOLES DO NOT DRAIN PROPERLY, EXCAVATE FURTHER UNTIL IMPERMEABLE LAYER IS BREACHED. EXCAVATED PLANT PITS SHALL HAVE POSITIVE DRAINAGE. PLANT PITS (WHEN FULLY FLOODED WITH WATER) SHALL DRAIN WITHIN 1 HOUR OF FILLING.

ENSURE THAT ALL PLANT PITS HAVE POSITIVE DRAINAGE.

5. ALL PLANTING BEDS SHALL BE TREATED WITH A PRE-EMERGENT HERBICIDE. PRE-EMERGENT HERBICIDE SHALL BE APPLIED PER MANUFACTURE'S RECOMMENDATIONS AND SHALL OCCUR AFTER TOPSOIL PLACEMENT AND PRIOR TO

INSTALLATION OF PLANT MATERIALS AND MULCH.

6. FERTILIZE ALL PLANTS AT THE TIME OF PLANTING WITH A TIME RELEASE FERTILIZER PER BRAND'S SPECIFIED

APPLICATION RATES.

7. ALL TREES AND SHRUBS SHALL BE PLANTED IN SUCH A MANNER AS TO ENSURE THEIR SURVIVAL.

8. ANY ROPE OR WIRE BINDING THE BALL SHALL BE CUT PRIOR TO PREVENT GIRDLING OF THE TREE. REMOVE WIRE, TWINE, AND BURLAP FROM THE TOP HALF OF ALL B&B PLANT MATERIAL.

9. IF A NON-BIODEGRADABLE MATERIAL IS USED AROUND THE BALL, IT SHALL BE COMPLETELY REMOVED PRIOR TO

BACKFILLING.

10. CONTRACTOR SHALL BE RESPONSIBLE FOR DELIVERY SCHEDULE AND PROTECTION BETWEEN DELIVERY AND

PLANTING TO MAINTAIN HEALTHY PLANT CONDITIONS.

11. ANY PLANT MATERIAL WHICH IS DISEASED, DISTRESSED, DEAD, OR REJECTED (PRIOR TO SUBSTANTIAL COMPLETION) SHALL BE PROMPTLY REMOVED FROM THE SITE AND REPLACED WITH MATERIAL OF THE SAME SPECIES, QUANTITY, AND SIZE AND MEETING ALL PLANT LIST SPECIFICATIONS. TREES & SHRUBS SHALL BE PLANTED AS

SOON AS POSSIBLE AFTER DELIVERY.

12. ALL TREES MUST BE STRAIGHT-TRUNKED, FULL-HEADED AND MEET ALL REQUIREMENTS SPECIFIED.

13. ALL TREES MUST BE STAKED AS SHOWN IN THE DETAILS.

14. NO SUBSTITUTIONS OR ALTERNATIVES WILL BE ALLOWED FOR GROUND SURFACE MATERIALS UNLESS

APPROVED IN WRITING BY THE LANDSCAPE ARCHITECT OR OWNER.

15. MAINTAIN 5' MIN. HORIZONTAL SEPARATION BETWEEN TREE PLANTINGS AND ALL UTILITIES UNLESS OTHERWISE

SPECIFIED.

16. A FOUR INCH (4") TOP DRESSING/MULCHING OF SHREDDED HARDWOOD MULCH SHALL BE PLACED AROUND ALL TREES. (SEE PLANTING DETAILS) TOP DRESSING CAN BE WOOD MULCH, ROCK, OR ANY OTHER DECORATIVE MATERIAL

SPECIFIED ON PLANS. SEE LANDSCAPE PLAN FOR TYPE.

17. THE FOLLOWING PLANTING SEASONS ARE RECOMMENDED:

EVERGREEN SHRUBBERY NOVEMBER - MARCH

DECIDUOUS SHRUBBERY & TREES NOVEMBER - MARCH

EVERGREEN TREES NOVEMBER - MARCH

18. CITY OF LEWISVILLE DOES NOT ALLOW TREE PLANTINGS BETWEEN THE MONTHS OF JUNE AND SEPTEMBER

PLANTING NOTES PLANT GUARANTEE, REPLACEMENT AND MAINTENANCE

A. GUARANTEE:

ACCEPTANCE OF TREE PLANTING SHALL BE BY LANDSCAPE ARCHITECT AND/OR OWNER. THE CONTRACTOR SHALL ASSUME MAINTENANCE RESPONSIBILITIES UNTIL FINAL ACCEPTANCE. MAINTENANCE SHALL INCLUDE WATERING, PRUNING AND OTHER OPERATIONS NECESSARY TO KEEP ALL TREES IN A THRIVING CONDITION. UPON FINAL

ACCEPTANCE, OWNER SHALL ASSUME ALL MAINTENANCE RESPONSIBILITIES.

B. REPLACEMENT:

ANY PLANT UNDER THIS SPEC WHICH IS DEAD, MISSING, UNHEALTHY, OR OTHERWISE NOT

ACCEPTABLE AND NOT IN SATISFACTORY GROWING CONDITION DURING CONSTRUCTION

MAINTENANCE PERIOD, OR AT THE END OF THE GUARANTEE PERIOD, SHALL BE REMOVED FROM SITE AND

REPLACED WITH SUITABLE, ACCEPTABLE PLANT AS SPECIFIED, WITHIN FIVE (5) DAYS.

C. MAINTENANCE:

GENERAL CONTRACTOR SHALL PROVIDE ONE YEAR OF LANDSCAPE MAINTENANCE, FROM THE TIME THE

PROJECT RECEIVES THE CERTIFICATE OF OCCUPANCY AND THERE AFTER, FOR ALL NEW LANDSCAPE. IF EXISTING LANDSCAPE EXISTS ON-SITE, GENERAL CONTRACTOR IS TO PROVIDE THE OPTION OF

MAINTENANCE FOR THE OWNER'S REVIEW.

1. APPLICATION OF HERBICIDES SHALL BE IN COMPLIANCE WITH STATE PESTICIDES REGULATIONS. IT IS THE RESPONSIBILITY OF THE LANDSCAPE CONTRACTOR TO CONSULT WITH THE REGULATORY AGENCIES FOR LOCAL

HERBICIDES APPLICATION REQUIREMENTS.

2. IF THERE IS A DISCREPANCY BETWEEN STATE REGULATIONS AND ADDITIONAL REQUIREMENTS BELOW, MOST

STRINGENT SHALL RULE

3. NO AERIAL APPLICATION OF HERBICIDES IS PERMITTED ON SITE.

4. CARCINOGENS AND EPA TOXIC CATEGORY I AND II ARE PROHIBITED TO USE ON SITE.

HERBICIDES NOTES

12"(MIN.)

FINISHED GRADE,

SEE GRADING PLAN

TREE WRAP

4 INCHES OF MULCH

4 INCH DEEP SAUCER

PLANTING PIT TO BE 2X THE

DIAMETER OF THE ROOT BALL

DUCKBILL UNDERGROUND TREE

ANCHOR OR EQUAL. MODEL 40-RBK FOR

2" CALIPER TREES MODEL 68-RBK FOR 3"

CALIPER TREES. INSTALL PER

MANUFACTURER'S SPECIFICATIONS

DUCKBILL ANCHORS, DRIVE ANCHORS FULL

DEPTH, D-RINGS TO REMAIN EXPOSED

FINISHED GRADE PER

GRADING PLAN

BACKFILL MIX PER SPECIFICATIONS

UNDISTURBED SUBSOIL

REMOVE BURLAP & ROPE

FROM TOP 1/3 OF THE BALL

2' (M

IN

12"(MIN.)

2' (M

IN

6"

NOTES:

1. DEPICTION ABOVE IS FOR TREE PLANTING ON A SLOPE.

2. ALL OTHER SPECIFICATIONS SHALL BE AS SHOWN BELOW IN THE TREE PLANTING DETAIL.

3. SEE TREE PLANTING DETAIL BELOW FOR TREE ANCHORING SYSTEM.

N.T.S.

TREE PLANTING

50A

DUCKBILL ANCHORS IN TRIANGULAR PATTERN. PASS

TENSION STRAPS THROUGH D-RING IN EACH ANCHOR

AND BACK TO EACH HAND RATCHET. TIGHTEN AND

ADJUST TENSION STRAP FOR BEST FIT.

PLAN

6"

NOTES:

1. SEE LANDSCAPE NOTES FOR THE TYPE OF MULCH MATERIAL TO USE.

2. CONTRACTOR TO ENSURE PERCOLATION OF PLANTING PITS PRIOR TO INSTALLATION.

3. CONTRACTOR TO CONTACT LANDSCAPE ARCHITECT IF PERCOLATION CANNOT BE ACHIEVED.

E. JONES STREET / CORPS OF ENGINEERS ROAD

OHE

OHE

OHE

OHE

OHE

OHE

OHE

OHE

EDGE OF WATER

LAKE LEW

ISVILLE SPILLW

AY

100-YR FLOODPLAIN PER

FEMA MAP 48121C0555G

100-YR FLOODPLAIN PER FEMA MAP 48121C0555G

100-YR FLOODPLAIN PER

FEMA MAP 48121C0555G

100-YR FLOODPLAIN PER

FEMA MAP 48121C0555G

WETLAND AREA PER

UPDATED IES (INTEGRATED

ENVIRONMENTAL

SOLUTIONS) ASSESSMENT -

FILE REFERENCE 04.354.211

DATED 10/17/2025

FLOODWAY PER UPDATED

IES (INTEGRATED

ENVIRONMENTAL

SOLUTIONS) ASSESSMENT -

FILE REFERENCE 04.354.211

DATED 10/17/2025

SCALE IN FEET

60'45'30'0

Know what's below.

before you dig.Call

CEI ENGINEERING ASSOCIATES, INC.

CEI PROJECT NUMBER

DATE

PROFESSIONAL OF RECORD

PROJECT MANAGER

DESIGNER

REVISION

PRELIMINARY

NOT FOR

CONSTRUCTION

SHEET NUMBER

SHEET TITLE

3030 LYNDON B JOHNSON FWY #920

DALLAS, TX 75234

PHONE: (972) 488-3737

FAX: ----

C3.0

OVERALL SITE PLAN

REV-1

11/19/2025

33855

WCM

MCR

KAP

LL

EL

A

KA

YA

K

LA

U

N

CH

LE

W

IS

VI

LL

E

LA

KE

LE

W

IS

VI

LL

E

LA

KE

S

PI

LL

W

AY

, E

JO

N

ES

S

T

LE

W

IS

VI

LL

E, T

X

DR

AW

IN

G

L O

CA

TI

O N

P:

\3

\3

.1 \D

RA

W

IN

G

S\

DE

SI

G

N \W

O

RK

IN

G

\3

.1

-S P.

DW

G

S

AV

ED

B Y

- W M

AL

LI

CO

TE

© 2025 CEI ENGINEERING ASSOCIATES, INC.

PROPOSED LEGEND

SITE BENCHMARK

BENCHMARK #1: A 5/8" REBAR WITH YELLOW CAP STAMPED "CEI

CONTROL" APPROXIMATELY 214' EAST OF A METAL FENCE POST.

ELEV= 466.72' NAVD88

N: 7,075,066.13 E: 2,438,724.29

BENCHMARK #2: A 5/8" REBAR WITH YELLOW CAP STAMPED "CEI

CONTROL" APPROXIMATELY 260' SOUTHEAST OF A METAL FENCE POST.

ELEV= 448.40' NAVD88

N:7,074,353.70

E: 32,438,944.83

BENCHMARK #3: A MAGNAIL WITH WASHER STAMPED "CEI CONTROL"

APPROXIMATELY 73' NORTHWEST OF TRAIL DESCRIPTION SIGN.

ELEV= 448.40' NAVD88

N:7,074,353.70

E: 32,438,944.83

EXISTING LEGEND

(Size)

T

Gas Line Underground Fiber Optic Line

Overhead Electric Line Sanitary Sewer Line

Storm Drainage Pipe

Underground Telephone Line

Water Line

Benchmark (BM)

Found Monument (As Noted)

Set 5/8" Rebar "LS#XXXX"

Electric Meter Guy Wire / Anchor

Utility Pole

Telephone Riser

Traffic Sign (Type of Sign)

GAS

FOC

OHE

SS

UGT

W

Break Line

Flow Line

Metal Fence Line

Standpipe

Bollard / Guard Post

Tree (Deciduous)

Tree (Evergreen)

(Size)

(Size)

Control Line

Edge of Gravel

Floodplain Area

Wetland Boundary Floodway Boundary

100-YEAR FLOODPLAIN

PROPERTY LINE/RIGHT OF WAY LINE

EDGE OF CONCRETE

HEAVY DUTY CONCRETE PAVING

GEOSYSTEMS GEOPAVE AGGREGATE POUROUS PAVEMENT WITH GRAVEL SURFACE

HYDROTURF RAMP SURFACE

CROSSGRIP NON-SLIP PVC ON EXISTING GRADE

HYDRO-SEED WITH STRAW EROSION MAT

CONCRETE RIBBON

CROSSGRIP NON-SLIP PVC WITH COMPACTED

AGGREGATE SUBBASE

PROPOSED GRAVEL SURFACE ROAD

HYDRO-SEED WITH STRAW EROSION MAT

LIMITS OF SIDEWALKS AND CONCRETE APRONS

6' BOARD FENCE

STEEL PIPE FENCE

E. JONES STREET / CORPS OF ENGINEERS ROAD

OHE

OHE

OHE

OHE

OHE

OHE

OHE

OHE

EDGE OF WATER

LAKE LEW

ISVILLE SPILLW

AY

100-YR FLOODPLAIN PER

FEMA MAP 48121C0555G

100-YR FLOODPLAIN PER FEMA MAP 48121C0555G

100-YR FLOODPLAIN PER

FEMA MAP 48121C0555G

100-YR FLOODPLAIN PER

FEMA MAP 48121C0555G

WETLAND AREA PER

UPDATED IES (INTEGRATED

ENVIRONMENTAL

SOLUTIONS) ASSESSMENT -

FILE REFERENCE 04.354.211

DATED 10/17/2025

FLOODWAY PER UPDATED

IES (INTEGRATED

ENVIRONMENTAL

SOLUTIONS) ASSESSMENT -

FILE REFERENCE 04.354.211

DATED 10/17/2025

12.5' 5'

24'

TYP.

18'

10'

5'

10' TYP.

' T

YP

13B

70A

70B

70C

08C

08E

08E 09S

09S

09U

70D

TYP.

70F

70AA

70G

1'

16'

80'

30'; EXTEND BEYOND

EDGE OF WATER AS NEEDED

12F

70S

20' TYP.

' T

YP

9' TYP.

18' TYP.

02A

70E

70AA

70AA

70AA

70E

' T

YP

20' TYP.

TYP. 02A

70E

70S

TYP.70T

70C12F

70C12F

TYP.70CC

12F

13B

13B

12F

TYP.70N

70M

TYP. 70P

70AA

70J

70K

70EE

07E

70E

TYP. 70P

70H

CENTERLINE LENGTH: 392FT

70DD

70Q

70K

70FF

70R

70GG

70GG 70GG

70GG

TYP.70GG

9'

18'

50'

5'

70HH70JJ TYP.

TYP. 70JJ

TYP. 70JJ

TYP. 70JJ

TYP. 70JJ

70M

70KKTYP.

TYP. 70T

PROPOSED LEGEND

GENERAL SITE NOTES

A. ALL DIMENSIONS SHOWN ARE TO THE FACE OF CURB UNLESS OTHERWISE NOTED.

B. ALL PARKING LOT SIGN BASE SUPPORTS SHALL BE INSTALLED PER DETAIL 12F.

C. ALL ACCESSIBLE PARKING STALLS SHALL HAVE SIGNAGE INSTALLED PER DETAIL 09S.

100-YEAR FLOODPLAIN

PROPERTY LINE/RIGHT OF WAY LINE

EDGE OF CONCRETE

PROPOSED PARKING SPACES

DISTURBANCE AREA

EXISTING PARKING

PARKING PROVIDED

1.4 ACRES (61,000 ± SF)

UNDEFINED ~33 SPACES

38 SPACES (4 ADA)

SITE DATA

SCALE IN FEET

60'45'30'0

Know what's below.

before you dig.Call

CEI ENGINEERING ASSOCIATES, INC.

CEI PROJECT NUMBER

DATE

PROFESSIONAL OF RECORD

PROJECT MANAGER

DESIGNER

REVISION

PRELIMINARY

NOT FOR

CONSTRUCTION

SHEET NUMBER

SHEET TITLE

3030 LYNDON B JOHNSON FWY #920

DALLAS, TX 75234

PHONE: (972) 488-3737

FAX: ----

C3.1

SITE PLAN

REV-1

11/19/2025

33855

WCM

MCR

KAP

LL

EL

A

KA

YA

K

LA

U

N

CH

LE

W

IS

VI

LL

E

LA

KE

LE

W

IS

VI

LL

E

LA

KE

S

PI

LL

W

AY

, E

JO

N

ES

S

T

LE

W

IS

VI

LL

E, T

X

DR

AW

IN

G

L O

CA

TI

O N

P:

\3

\3

.1 \D

RA

W

IN

G

S\

DE

SI

G

N \W

O

RK

IN

G

\3

.1

-S P.

DW

G

S

AV

ED

B Y

- W M

AL

LI

CO

TE

© 2025 CEI ENGINEERING ASSOCIATES, INC.

SITE BENCHMARK

BENCHMARK #1: A 5/8" REBAR WITH YELLOW CAP STAMPED "CEI

CONTROL" APPROXIMATELY 214' EAST OF A METAL FENCE POST.

ELEV= 466.72' NAVD88

N: 7,075,066.13 E: 2,438,724.29

BENCHMARK #2: A 5/8" REBAR WITH YELLOW CAP STAMPED "CEI

CONTROL" APPROXIMATELY 260' SOUTHEAST OF A METAL FENCE POST.

ELEV= 448.40' NAVD88

N:7,074,353.70

E: 32,438,944.83

BENCHMARK #3: A MAGNAIL WITH WASHER STAMPED "CEI CONTROL"

APPROXIMATELY 73' NORTHWEST OF TRAIL DESCRIPTION SIGN.

ELEV= 448.40' NAVD88

N:7,074,353.70

E: 32,438,944.83

SITE NOTES

13B LIMITS OF HEAVY DUTY CONCRETE PAVING.

70AA 10' STRIP ALONG BOTH SIDES OF ADA PATH AND LAUNCH RAMP TO BE HYDROSEEDED WITH NATIVE SEED MIX. BELOW

ELEV. 451' BIODEGRADABLE COIR MATTING TO BE SECURED ON TOP OF HYDROSEEDED AREAS WHEN GRADING

EXCEEDS 4:1

70CC ADA COMPLIANT PORTA-POTTY

70DD WASTE BINS LOCATION, BINS PROVIDED BY OTHERS

70EE TRANSITION PROPOSED GRAVEL PARKING LOT INTO EXISTING GRAVEL DRIVE; SURFACE SHOULD BE RAKED FLUSH INTO

EXISTING ROAD SURFACE

70FF PROPOSED RELOCATION OF EXISTING DUMPSTER

70GG GRAVEL SURFACE ROAD; NO SYNTHETIC REINFORCEMENT

70HH PYRAMAT SYNTHETIC EROSION CONTROL BLANKET; TOPPED WITH IN-SITU SOIL & SEEDED WITH NATIVE SEED MIX 70JJ PARKING STALL LINE DISPLAYED FOR GRAPHICAL REPRESENTATION ONLY; DO NOT PAINT IN FIELD 70KK 24"X24"X24" MINIMUM EXTERIOR DIMENSIONS, CUT LIMESTONE BLOCKS; SPLIT FACE FINISH

SITE DETAILS

02A PRECAST CONCRETE WHEEL STOP

07E 6' BOARD FENCE

08C HEAVY DUTY CONCRETE PAVING

08E STANDARD DUTY CONCRETE PAVING

09S ACCESSIBLE / VAN ACCESSIBLE PARKING SIGN

12F SIGN BASE

70A PORTA-POTTY DROP-OFF AREA; COMPACTED GRAVEL PAD

70B GEOSYSTEMS: GEOPAVE AGGREGATE POROUS PAVEMENT

70C LLELA PARKING SIGNAGE: "RESERVED KAYAK & CANOE PARKING"

70D LLELA KAYAK & CANOE INFORMATION SIGNAGE "NO UPSTREAM ACCESS" AND "LITTER DISPOSAL INFORMATION"

70E CONCRETE SIDEWALK PER LEWISVILLE DETAIL

70F HYDROTURF RAMP WITH CONCRETE SIDE ANCHORS

70G LAUNCH SURFACE: CROSSGRIP NON-SLIP PVC GROUND ANCHORED INTO EXISTING GRADE

70H CROSSGRIP NON-SLIP PVC WITH SYNTHETIC WRAPPED GABION (PYRAMATTRESS) SUBBASE

70J GEOPAVE & SIDEWALK

70K GEOPAVE & HEAVY DUTY CONCRETE

70M HYDROTURF ANCHOR TRENCH

70N CONCRETE RIBBON

70P STEEL PIPE FENCE

70Q STEEL PIPE HINGE GATE

70R NON-ACCESSIBLE ROUTE SIGNAGE

70S MODIFIED 90° ACCESSIBLE PARKING SPACE STRIPING

70T ACCESSIBLE PARKING SYMBOL

HEAVY DUTY CONCRETE PAVING

GEOSYSTEMS GEOPAVE AGGREGATE POUROUS PAVEMENT WITH GRAVEL SURFACE

HYDROTURF RAMP SURFACE

CROSSGRIP NON-SLIP PVC ON EXISTING GRADE

HYDRO-SEED WITH STRAW EROSION MAT

CONCRETE RIBBON

EXISTING LEGEND

(Size)

T

Gas Line

Underground Fiber Optic Line

Overhead Electric Line Sanitary Sewer Line

Storm Drainage Pipe

Underground Telephone Line

Water Line

Benchmark (BM)

Found Monument (As Noted)

Set 5/8" Rebar "LS#XXXX"

Electric Meter Guy Wire / Anchor

Utility Pole

Telephone Riser

Traffic Sign (Type of Sign)

GAS

FOC

OHE

SS

UGT

W

Break Line

Flow Line

Metal Fence Line

Standpipe

Bollard / Guard Post

Tree (Deciduous)

Tree (Evergreen)

(Size)

(Size)

Control Line

Edge of Gravel

CROSSGRIP NON-SLIP PVC WITH COMPACTED

AGGREGATE SUBBASE

PROPOSED GRAVEL SURFACE ROAD

HYDRO-SEED WITH STRAW EROSION MAT

LIMITS OF SIDEWALKS AND CONCRETE APRONS

Floodplain Area

Wetland Boundary Floodway Boundary

6' BOARD FENCE

STEEL PIPE FENCE

"CEI CONTROL POINT"

N: 7,075,066.13' E: 2,438,724.29'

Elev.= 466.72'

T

465.56grr 465.56grr 465.47grr465.46grr

GUARDRAIL

2 451

447 44

448449

ASPHALT PARKIN

G AREA

OHE

OHE

OHE

OHE

OHE

OHE

OHE

OHE

460459

100-YR FLOODPLAIN PER

FEMA MAP 48121C0555G

100-YR FLOODPLAIN PER FEMA MAP 48121C0555G

100-YR FLOODPLAIN PER

FEMA MAP 48121C0555G

100-YR FLOODPLAIN PER

FEMA MAP 48121C0555G

WETLAND AREA PER

UPDATED IES (INTEGRATED

ENVIRONMENTAL

SOLUTIONS) ASSESSMENT -

FILE REFERENCE 04.354.211

DATED 10/17/2025

FLOODWAY PER UPDATED

IES (INTEGRATED

ENVIRONMENTAL

SOLUTIONS) ASSESSMENT -

FILE REFERENCE 04.354.211

DATED 10/17/2025

FG 456.36

FG 456.95

FG 465.97

FG 466.02

FG 456.81

1.6%

7.

6%

6.

9%

1.5%

1.5% 1.

9%

1.4%

1.5%

1.8%

1.3

1.0%1.8%

1.6%

FG 465.44

FG 465.65

FG 465.59

18D

1.

1%

18D

18D

EG 466.58

EG 466.59

EG 466.95 EG 466.95

EG 466.92

EG 466.76

EG 466.35

EG 466.25

EG 466.00

EG 466.52

1.9%

1.6%

3.8%

4.5%

4.4%

3.7%

3.0%

2.8%

4.0% 4.6%

FG 466.14

FG 466.10

FG 465.94

FG 465.40

FG 465.22

FG 459.03

FG 458.66

FG 458.32

FG 458.09

FG 457.77

FG 458.14

FG 457.85

FG 458.23

FG 457.88

FG 457.68

FG 457.38

FG 458.00

FG 458.15

FG 457.15

FG 456.87

FG 457.31

FG 457.23

FG 457.33

FG 457.24

FG 457.80

FG 458.01

FG 458.17

FG 458.10

FG 458.17

FG 457.40

FG 457.63

FG 457.54

FG 457.47

FG 457.72

FG 457.64

FG 457.91

FG 458.07

FG 456.01

FG 456.18

FG 456.25

FG 453.72

FG 453.56

FG 453.46

FG 452.37

FG 452.11

FG 452.21

FG 449.44

FG 449.60

FG 449.67

FG 448.60

FG 448.53

FG 448.36

EG 447.10

EG 447.01

FG 466.12

FG 457.77

FG 466.31

FG 466.05

FG 465.78

FG 466.67

FG 466.69

FG 466.45

FG 466.39

1.3%

1.6%

FG 457.85

1.

6%

1.1%

PROPOSED LEGEND

GENERAL GRADING NOTES

A. ALL SLOPES AND AREAS DISTURBED BY CONSTRUCTION SHALL BE GRADED SMOOTH AND 4" OF TOPSOIL APPLIED. IF ADEQUATE TOPSOIL IS NOT AVAILABLE ON SITE, THE CONTRACTOR SHALL PROVIDE TOPSOIL, APPROVED BY THE OWNER, AS NEEDED. THE AREA SHALL THEN BE SEEDED, FERTILIZED, MULCHED, WATERED AND MAINTAINED UNTIL HARDY GRASS GROWTH IS ESTABLISHED IN ALL AREAS (SEE LANDSCAPE PLAN FOR SEED MIX AND PROPER APPLICATION RATE). ANY AREAS DISTURBED FOR ANY REASON PRIOR TO FINAL ACCEPTANCE OF THE PROJECT SHALL BE CORRECTED

BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER.

B. THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE.

THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANY AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO

REQUEST EXACT FIELD LOCATION OF UTILITIES.

PROPERTY LINE/RIGHT OF WAY LINE

GRADE BREAK

CONTOUR ELEVATIONS

SPOT ELEVATIONS:

TC = TOP OF CURB

G = GUTTER

LP = LOW POINT

FG = FINISH GRADEFLOWLINE

SCALE IN FEET

60'45'30'0

Know what's below.

before you dig.Call

CEI ENGINEERING ASSOCIATES, INC.

CEI PROJECT NUMBER

DATE

PROFESSIONAL OF RECORD

PROJECT MANAGER

DESIGNER

REVISION

PRELIMINARY

NOT FOR

CONSTRUCTION

SHEET NUMBER

SHEET TITLE

3030 LYNDON B JOHNSON FWY #920

DALLAS, TX 75234

PHONE: (972) 488-3737

FAX: ----

C4.0

GRADING PLAN

REV-1

12/18/2025

33855

WCM

MCR

KAP

LL

EL

A

KA

YA

K

LA

U

N

CH

LE

W

IS

VI

LL

E

LA

KE

LE

W

IS

VI

LL

E

LA

KE

S

PI

LL

W

AY

, E

JO

N

ES

S

T

LE

W

IS

VI

LL

E, T

X

DR

AW

IN

G

L O

CA

TI

O N

P:

\3

\3

.1 \D

RA

W

IN

G

S\

DE

SI

G

N \W

O

RK

IN

G

\3

.1

-G P.

DW

G

S

AV

ED

B Y

- W M

AL

LI

CO

TE

© 2025 CEI ENGINEERING ASSOCIATES, INC.

XXX

XX.XXx

SITE BENCHMARK

BENCHMARK #1: A 5/8" REBAR WITH YELLOW CAP STAMPED "CEI

CONTROL" APPROXIMATELY 214' EAST OF A METAL FENCE POST.

ELEV= 466.72' NAVD88

N: 7,075,066.13 E: 2,438,724.29

BENCHMARK #2: A 5/8" REBAR WITH YELLOW CAP STAMPED "CEI

CONTROL" APPROXIMATELY 260' SOUTHEAST OF A METAL FENCE POST.

ELEV= 448.40' NAVD88

N:7,074,353.70

E: 32,438,944.83

BENCHMARK #3: A MAGNAIL WITH WASHER STAMPED "CEI CONTROL"

APPROXIMATELY 73' NORTHWEST OF TRAIL DESCRIPTION SIGN.

ELEV= 448.40' NAVD88

N:7,074,353.70

E: 32,438,944.83

EXISTING LEGEND

(Size)

T

Gas Line Underground Fiber Optic Line

Overhead Electric Line Sanitary Sewer Line

Storm Drainage Pipe

Underground Telephone Line

Water Line

Benchmark (BM)

Found Monument (As Noted)

Set 5/8" Rebar "LS#XXXX"

Electric Meter Guy Wire / Anchor

Utility Pole

Telephone Riser

Traffic Sign (Type of Sign)

GAS

FOC

OHE

SS

UGT

W

Break Line

Flow Line

Metal Fence Line

Standpipe

Bollard / Guard Post

Tree (Deciduous)

Tree (Evergreen)

(Size)

(Size)

Control Line

Edge of Gravel

GRADING NOTES

18D MATCH EXISTING PAVEMENT ELEVATIONS.

OVERALL CUT/FILL COMPARISON TABLE

AREA AFFECTED CUT (CU. YDS) FILL (CU. YDS) NET (CU. YDS)

61,773.69 SF 422.13 355.57 66.56 (CUT)

Floodplain Area

Wetland Boundary

Floodway Boundary

FLOODPLAIN CUT/FILL COMPARISON TABLE

AREA AFFECTED CUT (CU. YDS) FILL (CU. YDS) NET (CU. YDS)

38,637.74 SF 221.12 179.87 41.25 (CUT)

Ramp PROFILE

VERTICAL SCALE: 1"=5'

HORIZONTAL SCALE: 1"=20'

1+00

EG

.4

FG

.4

1+20

EG

.5

FG

.5

1+40

EG

.7

FG

.7

1+60

EG

.5

FG

.5

1+80

EG

.8

FG

.8

2+00

EG

.7

FG

.7

2+20

EG

.9

FG

.9

2+40

EG

.0

FG

.0

2+60

EG

.6

FG

.6

2+80

EG

.8

FG

.8

3+00

EG

.2

FG

.2

3+20

EG

.0

FG

.0

3+40

EG

.4

FG

.4

3+60

EG

.5

FG

.5

3+80

EG

.8

FG

.8

4+00

EG

.3

FG

.3

4+20

EG FG

4+22

EG

FG

1+00

2+

3+

BP: 1+00

RIBBON CURB: 3+41.90

ORDINARY HIGH WATER MARK: 3+91.90

PC: 1+47.35

PC: 2+38.02

PT: 2+08

PT: 3+06.16

Mid: 1+77.68

Mid: 2+72.09 EDGE OF SURVEY; AVERAGE EDGE OF WATER: 4+08.46

END OF RAMP; ELEVATION ASSUMED: 4+22.00

448449

WETLAND AREA PER

UPDATED IES (INTEGRATED

ENVIRONMENTAL

SOLUTIONS) ASSESSMENT -

FILE REFERENCE 04.354.211

DATED 10/17/2025

FLOODWAY PER UPDATED

IES (INTEGRATED

ENVIRONMENTAL

SOLUTIONS) ASSESSMENT -

FILE REFERENCE 04.354.211

DATED 10/17/2025

FG 456.36

FG 456.95

FG 456.81

2.1%

1.

5%

1.4

1.0%2.1%

1.6%

1.

1%

1.9%

3.8%

4.5%

4.4%

3.7%

3.0%

2.8%

4.0%

4.6%

FG 458.00

FG 458.25

FG 457.71

FG 457.15

FG 456.87

FG 457.32

FG 457.51

FG 457.65

FG 457.49

FG 457.82

FG 458.06

FG 458.22

FG 458.10

FG 458.17

FG 457.91

FG 458.07

FG 456.01

FG 456.13

FG 456.25

FG 453.72

FG 453.60

FG 453.46

FG 452.37

FG 452.11

FG 452.25

FG 449.44

FG 449.56

FG 449.67

FG 448.60

FG 448.48

FG 448.36

EG 447.10

EG 447.01

1+00

2+00

3+00

4+00

4+22

RIBBON CURB: 3+41.90

ORDINARY HIGH WATER MARK: 3+91.90

EDGE OF SURVEY; AVERAGE EDGE OF WATER: 4+08.46

PC

: 1

+4 7.

PC: 2+38.02

PT: 2+08.00

PT: 3+06.16

BP

: N

:7

.1

E:

2.

END OF RAM

P: N:7074530.18

E:2438964.60

WETLAND AREA PER

UPDATED IES (INTEGRATED

ENVIRONMENTAL

SOLUTIONS) ASSESSMENT -

FILE REFERENCE 04.354.211

DATED 10/17/2025

FLOODWAY PER UPDATED

IES (INTEGRATED

ENVIRONMENTAL

SOLUTIONS) ASSESSMENT -

FILE REFERENCE 04.354.211

DATED 10/17/2025

CEI ENGINEERING ASSOCIATES, INC.

CEI PROJECT NUMBER

DATE

PROFESSIONAL OF RECORD

PROJECT MANAGER

DESIGNER

REVISION

PRELIMINARY

NOT FOR

CONSTRUCTION

SHEET NUMBER

SHEET TITLE

3030 LYNDON B JOHNSON FWY #920

DALLAS, TX 75234

PHONE: (972) 488-3737

FAX: ####

C5.0

PLAN & PROFILE -

WATER ACCESS RAMP

REV-1

12/18/2025

33855

WCM

MCR

KAP

LL

EL

A

KA

YA

K

LA

U

N

CH

LE

W

IS

VI

LL

E

LA

KE

LE

W

IS

VI

LL

E

LA

KE

S

PI

LL

W

AY

, E

JO

N

ES

S

T

LE

W

IS

VI

LL

E, T

X

DR

AW

IN

G

L O

CA

TI

O N

P:

\3

\3

.1 \D

RA

W

IN

G

S\

DE

SI

G

N \W

O

RK

IN

G

\3

.1

-P

P.

DW

G

S

AV

ED

B

Y

- W

M

AL

LI

CO

TE

© 2025 CEI ENGINEERING ASSOCIATES, INC.

0 20' 30' 40'

SCALE IN FEET

Floodplain Area

Floodway

Wetland Area

Wetland Boundary Floodway Boundary

CUT/FILL COMPARISON TABLE

AREA AFFECTED

(ACRES) AREA AFFECTED (SF) CUT (CU. YDS) FILL (CU. YDS) NET (CU. YDS)

1.418 61,773.69 422.13 355.57 66.56 (CUT)

PLAN LEGEND

Area of cut

Area of fill

NOTE: QUANTITIES ACCOUNT FOR ENTIRE SITE. TABLE PROVIDED FOR REVIEWER CONVENIENCE.

WETLAND AREA DISTURBANCE TABLE

MAXIMUM DISTURBANCE

ALLOWED (SF)

PROPOSED DISTURBANCE

(SF)

4,356 1,390

Existing Surface Proposed Surface

PROFILE LEGEND

PATH MATCHES EG FROM ORDINARY HIGH WATER MARK INTO WATER

"CEI CONTROL POINT"

N: 7,075,066.13' E: 2,438,724.29'

Elev.= 466.72'

T

465.56grr 465.56grr 465.47grr465.46grr

GUARDRAIL

2 451

447 44

448449

ASPHALT PARKIN

G AREA

OHE

OHE

OHE

OHE

OHE

OHE

OHE

OHE

460459

100-YR FLOODPLAIN PER

FEMA MAP 48121C0555G

100-YR FLOODPLAIN PER FEMA MAP 48121C0555G

100-YR FLOODPLAIN PER

FEMA MAP 48121C0555G

100-YR FLOODPLAIN PER

FEMA MAP 48121C0555G

WETLAND AREA PER

UPDATED IES (INTEGRATED

ENVIRONMENTAL

SOLUTIONS) ASSESSMENT -

FILE REFERENCE 04.354.211

DATED 10/17/2025

FLOODWAY PER UPDATED

IES (INTEGRATED

ENVIRONMENTAL

SOLUTIONS) ASSESSMENT -

FILE REFERENCE 04.354.211

DATED 10/17/2025

X

X

X

X

X

X X

X

X

X

X

X

X

X

X

X

X

X

X

1.6%

7.

6%

6.

9%

1.5%

1.5% 1.

9%

1.4%

1.5%

1.8%

1.3

1.0%1.8%

1.6%

75C

75C

75C

75C

75C 75C

85C

1.

1%

85A

80A

TYP. 75D

1.9%

1.6%

3.8%

4.5%

4.4%

3.7%

3.0%

2.8%

4.0% 4.6%

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SFSFSFSF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

SF

82H

1.3%

1.6%

1.

6%

1.1%

75A

CEI ENGINEERING ASSOCIATES, INC.

CEI PROJECT NUMBER

DATE

PROFESSIONAL OF RECORD

PROJECT MANAGER

DESIGNER

REVISION

PRELIMINARY

NOT FOR

CONSTRUCTION

SHEET NUMBER

SHEET TITLE

3030 LYNDON B JOHNSON FWY #920

DALLAS, TX 75234

PHONE: (972) 488-3737

FAX: ----

C6.0

EROSION CONTROL

PLAN

REV-1

12/18/2025

33855

WCM

MCR

KAP

LL

EL

A

KA

YA

K

LA

U

N

CH

LE

W

IS

VI

LL

E

LA

KE

LE

W

IS

VI

LL

E

LA

KE

S

PI

LL

W

AY

, E

JO

N

ES

S

T

LE

W

IS

VI

LL

E, T

X

DR

AW

IN

G

L O

CA

TI

O N

P:

\3

\3

.1 \D

RA

W

IN

G

S\

DE

SI

G

N \W

O

RK

IN

G

\3

.1

-G P.

DW

G

S

AV

ED

B Y

- W M

AL

LI

CO

TE

© 2025 CEI ENGINEERING ASSOCIATES, INC.

PROPOSED LEGEND

AREA OF DISTURBANCE = 1.4 ACRES (61,000 S.F.)

SF

CONSTRUCTION ENTRANCE

CONCRETE WASHOUT

ROCK CHECK DAM

SILT FENCE

GRADE BREAK

CONTOUR ELEVATIONS

LIMITS OF DISTURBANCE

PROPERTY LINE/RIGHT OF WAY LINE

XXX

SCALE IN FEET

60'45'30'0

Know what's below.

before you dig.Call

SITE BENCHMARK

BENCHMARK #1: A 5/8" REBAR WITH YELLOW CAP STAMPED "CEI

CONTROL" APPROXIMATELY 214' EAST OF A METAL FENCE POST.

ELEV= 466.72' NAVD88

N: 7,075,066.13 E: 2,438,724.29

BENCHMARK #2: A 5/8" REBAR WITH YELLOW CAP STAMPED "CEI

CONTROL" APPROXIMATELY 260' SOUTHEAST OF A METAL FENCE POST.

ELEV= 448.40' NAVD88

N:7,074,353.70

E: 32,438,944.83

BENCHMARK #3: A MAGNAIL WITH WASHER STAMPED "CEI CONTROL"

APPROXIMATELY 73' NORTHWEST OF TRAIL DESCRIPTION SIGN.

ELEV= 448.40' NAVD88

N:7,074,353.70

E: 32,438,944.83

EXISTING LEGEND

(Size)

T

Gas Line Underground Fiber Optic Line

Overhead Electric Line Sanitary Sewer Line

Storm Drainage Pipe

Underground Telephone Line

Water Line

Benchmark (BM)

Found Monument (As Noted)

Set 5/8" Rebar "LS#XXXX"

Electric Meter Guy Wire / Anchor

Utility Pole

Telephone Riser

Traffic Sign (Type of Sign)

GAS

FOC

OHE

SS

UGT

W

Break Line

Flow Line

Metal Fence Line

Standpipe

Bollard / Guard Post

Tree (Deciduous)

Tree (Evergreen)

(Size)

(…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .