Amendment 4 - RFP 15F06726R0000146.pdf

PDF 235 KB Posted

Attached to
Ammunition - 9mm Luger
Solicitation number
15F06726R0000146
Issued by

About this file

This is an amendment to Request for Proposal (RFP) 15F06726R0000146 for 9mm Luger ammunition in three categories: Service, Training, and Frangible. Amendment 001 was posted to SAM.gov on August 5, 2026, and modifies Section C.4.6.3 regarding temperature performance specifications.

The amendment clarifies that the 46,800 psi pressure limit when ammunition is fired at temperature extremes (-40°F and +140°F) applies specifically to Service Ammunition only. The original requirement stated that all ammunition must be safe to fire in firearms at temperatures between -40°F and +140°F with no single shot exceeding 46,800 psi. The revised language restricts this pressure specification to the Service Ammunition category, thereby allowing Training and Frangible ammunition variants to have different pressure performance characteristics at temperature extremes while maintaining the general safety requirement that all ammunition types be safe to fire across the specified temperature range.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Request for Proposal (RFP) 15F06726R0000146

Ammunition - 9mm Luger Service, Training, and Frangible

AMENDMENTS

Posted to SAM.gov on August 5, 2026

Amendment 001:

SECTION C.4.6.3

Remove:

Ammunition shall be safe to ϐire in ϐirearms at temperatures between -40°F and +140°F. When ϐired at temperature extremes (-40°F and +140°F), no single shot shall exceed 46,800 psi.

Replace:

Ammunition shall be safe to ϐire in ϐirearms at temperatures between -40°F and +140°F. For Service Ammunition, when ϐired at temperature extremes (-40°F and +140°F), no single shot shall exceed 46,800 psi.

File details come from the government source that posted it. Updated .