This is a Request for Quote (RFQ) from the Federal Bureau of Investigation's Finance Division Procurement Section for 50 commercial portable X-Ray systems. The RFQ number is 15F06726Q000602, and shipping costs within CONUS must be included in vendor pricing.
Each system must include 12 specified components: a controller-to-detector cable, diagonal tripod mount, controller, desktop charger, communication cable, detector with battery, additional battery pack, professional software license, carrying backpack, bipod stand, dual drive USB storage, and USB-C cable. The detector panel must meet minimum specifications including 14" × 17" dimensions, 310 µm scintillator thickness, pixel size of at least 148 µm, and internal lead shielding of at least 1mm. Critical system requirements include a controller-to-panel cable of at least 30 feet with quick-release capability, a detachable computer-to-controller cable of at least 160 feet, and a communication cable of at least 6 feet with ruggedized RJ45 interface compatible with the Persistent Systems LLC MPU5 MANET radio system. The detector must be ruggedized for field deployment with thermal management features and light-colored casing for extreme environmental conditions. The system must integrate fully with the Sandia National Laboratories X-ray Tool Kit with Unified Scan Control functionality and provide automatic network discovery compatible with the MPU5 MANET system. Vendors must provide operator training and technical support, obtain military base and FBI visitor access for delivery, provide a minimum two-year warranty covering defects in materials and workmanship, and supply all software updates and upgrades at no additional cost for two years from shipment.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment 2 Offeror Question and Answers Amendment 5.xlsx | XLSX spreadsheet | |
| Attachment 2 Offeror Question and Answers Amendment 4.xlsx | XLSX spreadsheet | |
| Attachment 2 Offeror Question and Answers Amendment 3.xlsx | XLSX spreadsheet | |
| Attachment 2 Offeror Question and Answers.xlsx | XLSX spreadsheet | |
| RFQ 15F06726Q000602 Amendment 1.pdf | ||
| Attachment 1.pdf | ||
| RFQ 15F06726Q000602.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FEDERAL BUREAU OF
INVESTIGATION
FINANCE DIVISION | PROCUREMENT SECTION
ATTACHMENT 1
Please note, this is not an Order
RFQ 15F06726Q000602
1.0 Supplies or Services:
The Federal Bureau of Investigation (FBI) requests 50 commercial portable X-Ray systems that match the specifications listed below. Shipping cost (within CONUS) is to be included in vendor’s pricing.
System Configuration
The package must include one of each of the following items per system
1. Controller to Detector Cable
2. Diagonal Tripod Mount for the Detector
3. Controller (between x-ray panel, generator and laptop)
4. Desktop Charger for Detector Batteries
5. Communication Cable to Rugged RJ45 for MPU5 module
6. Detector (including battery)
7. Additional Battery Pack
8. Professional Software License
9. Backpack to Carry Detector and Attachments
10. Bipod Detector Stand
11. Dual Drive Luxe USB Type-C
12. USB C Female to Controller Cable
Specifications
Each system and its included parts must meet or exceed the minimum specifications listed below.
1. The detector panel shall have minimum dimensions of 14 inches by 17 inches (14" × 17").
2. The detector panel shall utilize a scintillator with a thickness of 310 µm.
3. The detector panel shall have a pixel size of no less than 148 µm.
4. The detector panel shall incorporate internal shielding consisting of no less than 1mm of lead.
5. The system shall include a controller-to-panel cable with a length of no less than 30 feet.
6. The controller-to-panel cable shall have a secure connection with a quick release capability in the event of tension on the cable.
7. The system shall include a detachable computer-to-controller cable with a length of no less than 160 feet.
8. The system shall include a communication cable with a length of no less than 6 feet, terminating in a ruggedized RJ45 interface compatible with the Persistent Systems LLC MPU5 MANET radio system.
9. The system shall include an external battery charger compatible with commercially available rechargeable packs.
10. The detector shall be ruggedized and suitable for field deployment.
11. The detector panel shall incorporate thermal management features, light colored casing and face, sufficient to maintain operational performances across various environmental operating conditions to include extreme cold and heat.
12. The system shall be designed such that no more than one cable is required at the detector panel during placement and operation.
13. The system shall provide automatic network discovery, component identification, and synchronization functionality compatible with the Persistent Systems MPU5 MANET radio system.
14. The system shall be fully integrated with the Sandia National Laboratories X-ray Tool Kit and its embedded Unified Scan Control functionality, and operates without the user’s need to manipulate the image within the manufacturers embedded software.
15. The vendor shall provide operator training and technical support for all delivered systems, either directly or through an authorized representative.
16. The vendor must be able to obtain access to a military base as well as Federal Bureau of Investigation (FBI) visitor access for delivery.
17. The vendor shall provide a minimum two-year warranty from the date of shipment covering defects in materials and workmanship.
18. The vendor shall provide all software updates and upgrades at no additional cost for a minimum of two years from the date of shipment.