A512.pdf
PDF 348 KB Posted
- Attached to
- Building Masonry Repair at Quantico, Virginia
- Solicitation number
- 15DDHQ18Q00000171
About this file
Drawing A512
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFQ_Addendum_0006.pdf | ||
| RFQ_15DDHQ18Q00000171_Addendum_0005.pdf | ||
| RFQ_15DDHQ18Q00000171_Addendum_0004.pdf | ||
| RFQ_15DDHQ18Q00000171_Addendum_0003.pdf | ||
| QRFI_Masonry_Repair_Quantico_VA.pdf | ||
| A301.pdf | ||
| Request_for_Access_Form.pdf | ||
| A401.pdf | ||
| RFQ_15DDHQ18Q00000171.pdf | ||
| A302.pdf | ||
| A505.pdf | ||
| A303.pdf | ||
| A305.pdf | ||
| A402.pdf | ||
| A507.pdf | ||
| A503.pdf | ||
| A306.pdf | ||
| A508.pdf | ||
| A304.pdf | ||
| A504.pdf | ||
| A502.pdf | ||
| A509.pdf | ||
| A511.pdf | ||
| A513.pdf | ||
| A506.pdf |
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A512
DETAIL
SCALE:1 1/2"=1'-0"
SCALE:1 1/2"=1'-0"
DETAIL2
A512
SCALE:1 1/2"=1'-0"
DETAIL3
A512
A512
DETAIL
SCALE:1 1/2"=1'-0"
SCALE:1 1/2"=1'-0"
DETAIL6
A512
A512
DETAIL
SCALE:1 1/2"=1'-0"
ROOF SLAB
360'-0"
CONCRETE SLAB
2' -8
2"
1'-1 5/8"4 3/4"
1'-0" 6" 1/2" TYP.
1'-3" 3"
1'-4 1/4"1 3/4" 1/2" TYP.
1'-4"
4"7 5/8"4 3/8" 6"
2" 5" 1"2"1'-0"
3" 1'-
9" 2"
1/ 2"
1/ 2"
1/ 2"
3/ 8"
1'- 4"
2"
2' -8
1'-6" 6"
1'-2"4"
2' -8
1/ 2"
1'-7" 3"
1'-6" 4"
3"1'-3"
1'-4 1/4"1 3/4"
7 5/8" 6"
8"
2'-0" TYP.
SL. 1/2"/FT
SL.
SL.
SHT MET-3 COPING
WITH CLEATS
TREATED WOOD BLOCKING
SEALANT
PAVER-1 BALLAST
INSUL-1 RIGID INSULATION
SPR-1
FULLY ADHERED MEMBRANE
FLASHING TURN UP
UNDER COPING
LIGHTWEIGHT CONCRETE
FILL TAPER 1/2"/FT TO
MIN.1" THICK @ ROOF DRAIN
CONCRETE BEAM SEE STRUCTURAL
8" NOM. CMU
HORIZONTAL JOINT REINF.
AIR SPACE
BRICK VENEER
STEEL ANGLE BRACE
LATERAL SUPPORT SEE
STRUCTURAL DETAILS
GAP SPACE TO ALLOW FOR
ANTICIPATED STRUCTURAL
VERTICAL MOVEMENT
LOOSE LINTEL ANGLE
PER SCHEDULE SEE STRUCT
PAINT ALL EXPOSED SURFACES
TO MATCH BRICK, TYP.
ADJUSTABLE DOVETAIL
WITH CONCRETE INSET
@ 16" OC HORIZ.& VERT.
CMU BOND BEAM LINTEL
PER SCHEDULE SEE
STRUCTURAL DRAWINGS
SUSPENDED FINISH CEILING
PER SCHEDULE
PREFAB ALUMINUM BLIND
ALUMINUM WINDOW FRAME
PER SCHEDULE
CONTINUOUS SEALANT
CAST STONE CONCRETE
SILL TYPICAL @
WINDOW OPENINGS
THRU-WALL SILL FLASHING
WITH WEEPS @ 24" OC
(MIN. 2 PER OPENING)
TURN FLASHING UP @ JAMB
TO FORM ENDDAM TYP.
PREFAB ALUMINUM STOOL
TO RECEIVE GYB BD. STOOL
FINISH SAME AS WINDOW FRAME
BASE & FINISH FLOOR PER
SCHEDULE
THRU-WALL FLASHING
WEEPHOLES @ 24" OC, TYP.
SOFT JOINT WITH SEALANT
BELOW SHELF ANGLE, TYP.
ADJUSTABLE CONCRETE
INSERTS @ 24" OC MAXIMUM
SPACING, TYP. UNLESS
OTHERWISE NOTED. SEE
STRUCTURAL DRAWINGS
FOR REINFORCING &
ADDITIONAL NOTES
5"X5"X3/8" GALVANIZED
BRICK SHELF ANGLE
FILL GAP SPACE WITH
SAFING INSULATION
SEALANT
MP-2 METAL WALL PANEL
SYSTEM ON METAL FURRING
1/2" SEALANT JOINT
FLASHING WITH WEEPS
PRECAST PANEL
CONNECTION POCKET
FILL POCKET WITH
CONCRETE AFTER
PRECAST IS SET
SAFING INSULATION
APC-1
SEALANT
CONTINUOUS DRIP GROOVE
TYPICAL
RADIANT HEATING PANEL
WITH REVEALED MOUNTING
TRIM SEE MECHANICAL
DRWGS FOR LOCATION
GYB BD BULKHEAD ON
METAL STUD FRAMING
1" INSULATED GLASS
PER SCHEDULE
ALUMINUM STOREFRONT
FRAME WITH THERMAL
BREAK SEE STOREFRONT
SCHEDULE FOR SIZES
& DIMENSIONS
SUSPENDED FINISH CEILING
8" WIDE
PREFAB ALUMINUM STOOL
TO RECEIVE GYB BD
FINISH STOOL SAME AS
STOREFRONT FRAME
INSUL-21
MP-2 SPANDREL WITH
INSULATION SET IN
STOREFRONT FRAME
BASE & FINISH FLOOR
PER SCHEDULE
METAL SILL FLASHING
WITH WEEPS
1/2" SEALANT & BACKER
ROD
APC-1 SEE TYPICAL NOTES
& DIMENSIONS DETAIL 3/A512
PRECAST CONNECTION
CONCRETE BEAM SEE
STRUCTURAL DRWGS.
FILL WITH SAFING INSULATION
INSUL-21
RADIANT PANEL SEE MECHANICAL
NOTE:
PRECAST PANEL CONNECTION DETAILS SHOWN
ARE SCHEMATIC. PRECAST MANUFACTURER
SHALL DESIGN ALL CONNECTION DETAILS.
ALL RELATED TRADES SHALL COORDINATE
WITH PRECAST CONNECTIONS & DIMENSIONS
SL.
ALUMINUM STOREFRONT
PER SCHEDULE
1" INSULATING TEMPERED
GLASS
PEDESTAL MOUNTED FINNED
TUBE HOUSING SEE MECH.
FOR SIZE & LOCATION
1/8" BREAK METAL
CLOSURE PLATE @ SILL
TYPICAL
SAFING INSULATION
APC-1
SEE 3/A512 FOR ADDITIONAL
NOTES & DIMENSIONS
CONTINUOUS DRIP GROOVE
1/2" METAL TRIM EDGE
REVEAL
PLS-11 SOFFIT DESIGN
FOR UPLIFT FORCE
ALUMINUM STOREFRONT
FRAME PER SCHEDULE
5/8" EXTERIOR GYB BD SHEATHING
ON METAL STUD FRAMING
STEEL ANGLE SUPPORT FRAME @
48" OC MAX SPACING FOR STOREFRONT
VAPOR BARRIER
INSUL-21
ALUMINUM WINDOW FRAME PER SCHEDULE
1" INSULATING GLASS
SEALANT TYP. BOTH SIDES
CAST STONE CONCRETE SILL
SILL FLASHING WITH WEEPS
BRICK VENEER
AIR SPACE
BITUMINUOUS DAMPPROOFING
PEA GRAVEL
THRU-WALL FLASHING WITH
WEEPS @ 24" OC
GROUT SOLID BELOW FLASHING
APPROXIMATE FINISH GRADE
SEE CIVIL DRWGS.
2" INSUL-1 PERIMETER INSULATION
24" WIDE TYPICAL
VAPOR BARRIER
COMPACT GRAVEL
CONCRETE FOUNDATION FOOTING
SEE STRUCTURAL FOR DETAILS
& DIMENSIONS
SEE TYPICAL WALL
CONSTRUCTION 2/A501 8" NOM. CMU
COL
SPECIAL SHELF BRICK @ ANGLE TYP.
LINEAR DIFFUSER
SEE MECH. DRWGS.
LINEAR DIFFUSER
LINEAR DIFFUSER
5"
3"
MIN
3"
MIN
C-11
TYPE
LIGHT
FIXTURE
A512
DETAIL
SCALE:1 1/2"=1'-0"
SCALE:1 1/2"=1'-0"
DETAIL2
A512
SCALE:1 1/2"=1'-0"
DETAIL3
A512
A512
DETAIL
SCALE:1 1/2"=1'-0"
SCALE:1 1/2"=1'-0"
DETAIL6
A512
A512
DETAIL
SCALE:1 1/2"=1'-0"
ROOF SLAB
360'-0"
CONCRETE SLAB
2' -8
2"
1'-1 5/8"4 3/4"
1'-0" 6" 1/2" TYP.
1'-3" 3"
1'-4 1/4"1 3/4" 1/2" TYP.
1'-4"
4"7 5/8"4 3/8" 6"
2" 5" 1"2"1'-0"
3" 1'-
9" 2"
1/ 2"
1/ 2"
1/ 2"
3/ 8"
1'- 4"
2"
2' -8
1'-6" 6"
1'-2"4"
2' -8
1/ 2"
1'-7" 3"
1'-6" 4"
3"1'-3"
1'-4 1/4"1 3/4"
7 5/8" 6"
8"
2'-0" TYP.
SL. 1/2"/FT
SL.
SL.
SHT MET-3 COPING
WITH CLEATS
TREATED WOOD BLOCKING
SEALANT
PAVER-1 BALLAST
INSUL-1 RIGID INSULATION
SPR-1
FULLY ADHERED MEMBRANE
FLASHING TURN UP
UNDER COPING
LIGHTWEIGHT CONCRETE
FILL TAPER 1/2"/FT TO
MIN.1" THICK @ ROOF DRAIN
CONCRETE BEAM SEE STRUCTURAL
8" NOM. CMU
HORIZONTAL JOINT REINF.
AIR SPACE
BRICK VENEER
STEEL ANGLE BRACE
LATERAL SUPPORT SEE
STRUCTURAL DETAILS
GAP SPACE TO ALLOW FOR
ANTICIPATED STRUCTURAL
VERTICAL MOVEMENT
LOOSE LINTEL ANGLE
PER SCHEDULE SEE STRUCT
PAINT ALL EXPOSED SURFACES
TO MATCH BRICK, TYP.
ADJUSTABLE DOVETAIL
WITH CONCRETE INSET
@ 16" OC HORIZ.& VERT.
CMU BOND BEAM LINTEL
PER SCHEDULE SEE
STRUCTURAL DRAWINGS
SUSPENDED FINISH CEILING
PER SCHEDULE
PREFAB ALUMINUM BLIND
ALUMINUM WINDOW FRAME
PER SCHEDULE
CONTINUOUS SEALANT
CAST STONE CONCRETE
SILL TYPICAL @
WINDOW OPENINGS
THRU-WALL SILL FLASHING
WITH WEEPS @ 24" OC
(MIN. 2 PER OPENING)
TURN FLASHING UP @ JAMB
TO FORM ENDDAM TYP.
PREFAB ALUMINUM STOOL
TO RECEIVE GYB BD. STOOL
FINISH SAME AS WINDOW FRAME
BASE & FINISH FLOOR PER
SCHEDULE
THRU-WALL FLASHING
WEEPHOLES @ 24" OC, TYP.
SOFT JOINT WITH SEALANT
BELOW SHELF ANGLE, TYP.
ADJUSTABLE CONCRETE
INSERTS @ 24" OC MAXIMUM
SPACING, TYP. UNLESS
OTHERWISE NOTED. SEE
STRUCTURAL DRAWINGS
FOR REINFORCING &
ADDITIONAL NOTES
5"X5"X3/8" GALVANIZED
BRICK SHELF ANGLE
FILL GAP SPACE WITH
SAFING INSULATION
SEALANT
MP-2 METAL WALL PANEL
SYSTEM ON METAL FURRING
1/2" SEALANT JOINT
FLASHING WITH WEEPS
PRECAST PANEL
CONNECTION POCKET
FILL POCKET WITH
CONCRETE AFTER
PRECAST IS SET
SAFING INSULATION
APC-1
SEALANT
CONTINUOUS DRIP GROOVE
TYPICAL
RADIANT HEATING PANEL
WITH REVEALED MOUNTING
TRIM SEE MECHANICAL
DRWGS FOR LOCATION
GYB BD BULKHEAD ON
METAL STUD FRAMING
1" INSULATED GLASS
PER SCHEDULE
ALUMINUM STOREFRONT
FRAME WITH THERMAL
BREAK SEE STOREFRONT
SCHEDULE FOR SIZES
& DIMENSIONS
SUSPENDED FINISH CEILING
8" WIDE
PREFAB ALUMINUM STOOL
TO RECEIVE GYB BD
FINISH STOOL SAME AS
STOREFRONT FRAME
INSUL-21
MP-2 SPANDREL WITH
INSULATION SET IN
STOREFRONT FRAME
BASE & FINISH FLOOR
PER SCHEDULE
METAL SILL FLASHING
WITH WEEPS
1/2" SEALANT & BACKER
ROD
APC-1 SEE TYPICAL NOTES
& DIMENSIONS DETAIL 3/A512
PRECAST CONNECTION
CONCRETE BEAM SEE
STRUCTURAL DRWGS.
FILL WITH SAFING INSULATION
INSUL-21
RADIANT PANEL SEE MECHANICAL
NOTE:
PRECAST PANEL CONNECTION DETAILS SHOWN
ARE SCHEMATIC. PRECAST MANUFACTURER
SHALL DESIGN ALL CONNECTION DETAILS.
ALL RELATED TRADES SHALL COORDINATE
WITH PRECAST CONNECTIONS & DIMENSIONS
SL.
ALUMINUM STOREFRONT
PER SCHEDULE
1" INSULATING TEMPERED
GLASS
PEDESTAL MOUNTED FINNED
TUBE HOUSING SEE MECH.
FOR SIZE & LOCATION
1/8" BREAK METAL
CLOSURE PLATE @ SILL
TYPICAL
SAFING INSULATION
APC-1
SEE 3/A512 FOR ADDITIONAL
NOTES & DIMENSIONS
CONTINUOUS DRIP GROOVE
1/2" METAL TRIM EDGE
REVEAL
PLS-11 SOFFIT DESIGN
FOR UPLIFT FORCE
ALUMINUM STOREFRONT
FRAME PER SCHEDULE
5/8" EXTERIOR GYB BD SHEATHING
ON METAL STUD FRAMING
STEEL ANGLE SUPPORT FRAME @
48" OC MAX SPACING FOR STOREFRONT
VAPOR BARRIER
INSUL-21
ALUMINUM WINDOW FRAME PER SCHEDULE
1" INSULATING GLASS
SEALANT TYP. BOTH SIDES
CAST STONE CONCRETE SILL
SILL FLASHING WITH WEEPS
BRICK VENEER
AIR SPACE
BITUMINUOUS DAMPPROOFING
PEA GRAVEL
THRU-WALL FLASHING WITH
WEEPS @ 24" OC
GROUT SOLID BELOW FLASHING
APPROXIMATE FINISH GRADE
SEE CIVIL DRWGS.
2" INSUL-1 PERIMETER INSULATION
24" WIDE TYPICAL
VAPOR BARRIER
COMPACT GRAVEL
CONCRETE FOUNDATION FOOTING
SEE STRUCTURAL FOR DETAILS
& DIMENSIONS
SEE TYPICAL WALL
CONSTRUCTION 2/A501 8" NOM. CMU
COL
SPECIAL SHELF BRICK @ ANGLE TYP.
LINEAR DIFFUSER
SEE MECH. DRWGS.
LINEAR DIFFUSER
LINEAR DIFFUSER
5"
3"
MIN
3"
MIN
C-11
TYPE
LIGHT
FIXTURE
Washington, D.C. 20009 Comm Number 7782 921A
1875 Connecticut Ave. NW Suite 600
SUPV
SUBMITTED BY
TITLE
CHKDRWN
CH ENGR
408 404 40504B
D/M/YR
D/M/YRAPPROVED
APPROVED
EFD FOR COMMANDER, NAVFAC
D/M/YR
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
CHESAPEAKE DIVISION, WASHINGTON D.C.
SCALE SPEC SHEET 21-92-0193 OF
SIZE CODE IDENT NO.
Drug Enforcement Administration Justice Training CenterQuantico, Virginia
F 80091 CONSTR. CONTR. NO.
NAVFAC DRWING NUMBER
N62477-92-C-0193
E.I.C. 403 40204
09A 401
LTR
REVISION
DESCRIPTION DATE APPRV'D.
NS ACH
WMC CFK
CHIEF ARCHITECT
A512
3080631
GRAPHIC 87 329
EXTERIOR SECTIONAL DETAILS
1-1/2" = 1'-0"
1'9"6"0 3"
SCALE MUST BE USED.
REDUCTION, GRAPHIC
IF DRAWING IS A
CAUTION:
1 RFI # 214-CLARIFICATION 3-24-98
RECORD DRAWING November 14, 2002
2 PC # 117
| Model |
| Layout1 |
File details come from the government source that posted it.