A306.pdf
PDF 433 KB Posted
- Attached to
- Building Masonry Repair at Quantico, Virginia
- Solicitation number
- 15DDHQ18Q00000171
About this file
Drawing A306
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFQ_Addendum_0006.pdf | ||
| RFQ_15DDHQ18Q00000171_Addendum_0005.pdf | ||
| RFQ_15DDHQ18Q00000171_Addendum_0004.pdf | ||
| RFQ_15DDHQ18Q00000171_Addendum_0003.pdf | ||
| QRFI_Masonry_Repair_Quantico_VA.pdf | ||
| A301.pdf | ||
| Request_for_Access_Form.pdf | ||
| A401.pdf | ||
| RFQ_15DDHQ18Q00000171.pdf | ||
| A302.pdf | ||
| A505.pdf | ||
| A303.pdf | ||
| A305.pdf | ||
| A402.pdf | ||
| A507.pdf | ||
| A503.pdf | ||
| A508.pdf | ||
| A512.pdf | ||
| A304.pdf | ||
| A504.pdf | ||
| A502.pdf | ||
| A509.pdf | ||
| A511.pdf | ||
| A513.pdf | ||
| A506.pdf |
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Washington, D.C. 20009 Comm Number 7782 921A
1875 Connecticut Ave. NW Suite 600
SUPV
SUBMITTED BY
TITLE
CHKDRWN
CH ENGR
408 404 40504B
D/M/YR
D/M/YRAPPROVED
APPROVED
EFD FOR COMMANDER, NAVFAC
D/M/YR
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
CHESAPEAKE DIVISION, WASHINGTON D.C.
SCALE SPEC SHEET 21-92-0193 OF
SIZE CODE IDENT NO.
Drug Enforcement Administration Justice Training CenterQuantico, Virginia
F 80091 CONSTR. CONTR. NO.
NAVFAC DRWING NUMBER
N62477-92-C-0193
E.I.C. 403 40204
09A 401
LTR
REVISION
DESCRIPTION DATE APPRV'D.
MLM ACH
WMC CFK
CHIEF ARCHITECT
A306
3060618
GRAPHIC 74 329
ENLARGED
EXTERIOR ELEVATIONS
A306
ELEVATION @ SPECIAL FUNCTIONS DINING 2
A306
ELEVATION @ SPECIAL FUNCTIONS DINING 3
A306
ELEVATION @ STAFF DINING
A306
PLAZA ELEVATION @ INTERNATIONAL CLASSROOM 5
A306
SOUTHWEST ELEVATION @ INTERNATIONAL CLASSROOM
.91 0.2 0.1
A504
A503
0"
ROOF/PLAZA
+322'-0"
GROUND FLR
+308'-0"
A503
0.4 0.3
1ST FLOOR
+322'-0"
1ST FLOOR
+322'-0"
AAA
BR-1
APC-1
MP-2
BR-1
SF-16
GFRC
COLUMN
COVER
GFRC COLUMN
COVER
MP-2
APC-1
CMU-5
APC-1
CMU-5
APC-1
SF-11
JJ HH
+308'-0"
GROUND FLR
+322'-0"
ROOF/PLAZA
0"
BR-1
CMU-5
SF-12
MP-2
BR-1
ELEVATION @ STAFF DINING6
A306
ROOF/PLAZA
+322'-0"
+308'-0"
GROUND FLR
0"
1/4" = 1'-0"
5'2'1'0
PERFORATED ALUM. SOFFIT
METAL ROOF
MATERIALS LEGEND:
BRICK 1 (BR-1)
BRICK 2 (BR-2)
NOTES:
1. REFER TO ARCHITECTURAL FLOOR PLANS FOR WINDOW TYPE
DESIGNATIONS AND HORIZONTAL DIMENSIONS AND PLAN DETAILS.
2. REFER TO REFERENCED SECTIONS FOR ADDITIONAL VERTICAL
DIMENSIONS AND SECTIONAL DETAILS.
3. REFER TO MATERIALS LEGENDS FOR APPLICABLE FACE MATERIALS.
RUNNING BOND SOLDIER COURSE BRICK
SEE ELEVATION FOR BRICK TYPE
SPLIT FACED CONC. BLOCK (CMU-5) PRECAST CONC. (APC-1)
CORRUGATED METAL PANEL (MP-1)
METAL PANEL (MP-2)
LOUVER
SCALE MUST BE USED.
REDUCTION, GRAPHIC
IF DRAWING IS A
CAUTION:
A504
A504
SF-13
A509
SF-15
A509
SF-10C
SIM.
A503
JJ
A504
A504 SIM.
REV.
MP-2
BR-1
CMU-5
MS-1(NON
PERFORATED)
MP-2
MS-1(NON
PERFORATED)
MS-1(PERFORATED)
TOP OF SLAB
+305'-10"
3' -6
MI
N.
A509 SIM.
HH
EXP JT. SEE
7/A523 SIM.
1 BULLETIN # 1 10/10/97
RECORD DRAWING November 14, 2002
| Model |
| Layout1 |
File details come from the government source that posted it.