A303.pdf
PDF 325 KB Posted
- Attached to
- Building Masonry Repair at Quantico, Virginia
- Solicitation number
- 15DDHQ18Q00000171
About this file
Drawing A303
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFQ_Addendum_0006.pdf | ||
| RFQ_15DDHQ18Q00000171_Addendum_0005.pdf | ||
| RFQ_15DDHQ18Q00000171_Addendum_0004.pdf | ||
| RFQ_15DDHQ18Q00000171_Addendum_0003.pdf | ||
| QRFI_Masonry_Repair_Quantico_VA.pdf | ||
| A301.pdf | ||
| Request_for_Access_Form.pdf | ||
| A401.pdf | ||
| RFQ_15DDHQ18Q00000171.pdf | ||
| A302.pdf | ||
| A505.pdf | ||
| A305.pdf | ||
| A402.pdf | ||
| A507.pdf | ||
| A503.pdf | ||
| A306.pdf | ||
| A508.pdf | ||
| A512.pdf | ||
| A304.pdf | ||
| A504.pdf | ||
| A502.pdf | ||
| A509.pdf | ||
| A511.pdf | ||
| A513.pdf | ||
| A506.pdf |
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Washington, D.C. 20009 Comm Number 7782 921A
1875 Connecticut Ave. NW Suite 600
SUPV
SUBMITTED BY
TITLE
CHKDRWN
CH ENGR
408 404 40504B
D/M/YR
D/M/YRAPPROVED
APPROVED
EFD FOR COMMANDER, NAVFAC
D/M/YR
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
CHESAPEAKE DIVISION, WASHINGTON D.C.
SCALE SPEC SHEET 21-92-0193 OF
SIZE CODE IDENT NO.
Drug Enforcement Administration Justice Training CenterQuantico, Virginia
F 80091 CONSTR. CONTR. NO.
NAVFAC DRWING NUMBER
N62477-92-C-0193
E.I.C. 403 40204
09A 401
LTR
REVISION
DESCRIPTION DATE APPRV'D.
MLM ACH
WMC CFK
CHIEF ARCHITECT
A303
3080615
GRAPHIC 71 329
ENLARGED
EXTERIOR ELEVATIONSSECTOR B
SECTOR A
SECTOR C
KEY PLAN
N
A303
PLAZA ELEVATION @ STAIR HALLPLAZA ELEVATION @ OFFICE ENTRY1
A303
A505
0"
0"
0"
ROOF (L.P.)
+360'-0"
3RD FLOOR
+348'-0"
2ND FLOOR
+336'-0"
1ST FLOOR
+322'-0"
0"
0"
ROOF (L.P.)
+348'-0"
2ND FLOOR
+336'-0"
1ST FLOOR
+322'-0"
0.82
A505
A503
MP-1
SHT-MET-3
COPING
BR-1
W-
BR-1
SF-19
SF-18
SF-
SF-
BR-1
APC-1
BR-1
MP-2
SHT-MET-3
COPING
BR-1
MP-1
SF-17
BR-1
MP-1
BR-1
BR-1
APC-1
MP-2
SHT-MET-3
COPING
SF-17
CW-2
BR-1
MP-2
3. REFER TO MATERIALS LEGENDS FOR APPLICABLE FACE MATERIALS.
DIMENSIONS AND SECTIONAL DETAILS.
2. REFER TO REFERENCED SECTIONS FOR ADDITIONAL VERTICAL
DESIGNATIONS AND HORIZONTAL DIMENSIONS AND PLAN DETAILS.
1. REFER TO ARCHITECTURAL FLOOR PLANS FOR WINDOW TYPE
NOTES:
LOUVER
METAL PANEL (MP-2)
CORRUGATED METAL PANEL (MP-1)
PRECAST CONC. (APC-1)
SPLIT FACED CONC. BLOCK (CMU-5)
BRICK 2 (BR-2)
BRICK 1 (BR-1)
MATERIALS LEGEND:
RUNNING BOND SOLDIER COURSE BRICK
METAL
ROOF
PERF.
METAL
SOFFIT
METAL ROOF
PERFORATED ALUM. SOFFIT
1/4" = 1'-0"
5'2'1'0
C.J.
C.J.
C.J.
CAST
STONE
TYP.
BR-1
(NOTE:
HEADER
COURSE
PATTERN
SHOWN IS
TYPICAL)
C.J.
SEE ELEVATION FOR BRICK TYPE
STL CABLE
SEE STRUCT.
APC-1
SCALE MUST BE USED.
REDUCTION, GRAPHIC
IF DRAWING IS A
CAUTION:
A508
LIGHT FIXT.
SEE ELEC.
SF-32
BEYOND
L303 TYP.
DRUG ENFORCEMENT ADMINISTRATION
JUSTICE TRAINING CENTER
SEE SHEET ID312 FOR SIGNAGE INFORMATION
CAST STONE COPING
COPING
CAST STONE GRFC
ALUM
COLUMN
COVER
COLUMN
COVER
3' -8
2' -8
RECORD DRAWING November 14, 2002
| Model |
| Layout1 |
File details come from the government source that posted it.