A402.pdf
PDF 332 KB Posted
- Attached to
- Building Masonry Repair at Quantico, Virginia
- Solicitation number
- 15DDHQ18Q00000171
About this file
Drawing A402
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFQ_Addendum_0006.pdf | ||
| RFQ_15DDHQ18Q00000171_Addendum_0005.pdf | ||
| RFQ_15DDHQ18Q00000171_Addendum_0004.pdf | ||
| RFQ_15DDHQ18Q00000171_Addendum_0003.pdf | ||
| QRFI_Masonry_Repair_Quantico_VA.pdf | ||
| A301.pdf | ||
| Request_for_Access_Form.pdf | ||
| A401.pdf | ||
| RFQ_15DDHQ18Q00000171.pdf | ||
| A302.pdf | ||
| A505.pdf | ||
| A303.pdf | ||
| A305.pdf | ||
| A507.pdf | ||
| A503.pdf | ||
| A306.pdf | ||
| A508.pdf | ||
| A512.pdf | ||
| A304.pdf | ||
| A504.pdf | ||
| A502.pdf | ||
| A509.pdf | ||
| A511.pdf | ||
| A513.pdf | ||
| A506.pdf |
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTOR B
SECTOR A
SECTOR C
KEY PLAN
N
Washington, D.C. 20009 Comm Number 7782 921A
1875 Connecticut Ave. NW Suite 600
SUPV
SUBMITTED BY
TITLE
CHKDRWN
CH ENGR
408 404 40504B
D/M/YR
D/M/YRAPPROVED
APPROVED
EFD FOR COMMANDER, NAVFAC
D/M/YR
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
CHESAPEAKE DIVISION, WASHINGTON D.C.
SCALE SPEC SHEET 21-92-0193 OF
SIZE CODE IDENT NO.
Drug Enforcement Administration Justice Training CenterQuantico, Virginia
F 80091 CONSTR. CONTR. NO.
NAVFAC DRWING NUMBER
N62477-92-C-0193
E.I.C. 403 40204
09A 401
LTR
REVISION
DESCRIPTION DATE APPRV'D.
ACH ACH
WMC CFK
CHIEF ARCHITECT
A402
3080620
GRAPHIC 76 329
BUILDING
SECTIONS
A402
10 9 8 7 62 A507
5 4 3 2 1 D8 D7 D6 D5 D4 D3 D2 D1
A507 5
A501
A501
A506
A402
SECTION THROUGH OFFICE/CLASSROOM CORRIDOR FACING SOUTHEAST
10 9 8 7 6 5 4 3 2 0.9
A507 6 A508
A402
SECTION THROUGH OFFICE/HALL OF HONOR/INTERNATIONAL CLASSROOM FACING SOUTHEAST
10 9 8 7 6 5 4 3 2 0.8 0.7 0.5 0.4 0.3
A508
A505
A509
D9
A501
A505
0.9
0"
0"
0"
0"
0"
PENTHOUSE
+360'-0"
3RD FLOOR
+348'-0"
2ND FLOOR
+336'-0"
1ST FLOOR
+322'-0"
GROUND FLOOR
+308'-0"
ROOF
+374'-0" L.P.
0"
0"
0"
0"
0"
GROUND FLOOR
+308'-0"
1ST FLOOR
+322'-0"
2ND FLOOR
+336'-0"
3RD FLOOR
+348'-0"
+360'-0"
ROOF
ROOF
+374'-0" L.P.
0"
0"
0"
0"
GROUND FLOOR
+308'-0"
1ST FLOOR
+322'-0"
2ND FLOOR
+336'-0"
3RD FLOOR
+348'-0"
+360'-0"
ROOF
A402
A402
A402
0.9 2 3 4 5 6
0"
0"
0"
0"
0"
GROUND FLOOR
+308'-0"
1ST FLOOR
+322'-0"
2ND FLOOR
+336'-0"
3RD FLOOR
+348'-0"
PENTHOUSE
+360'-0"
TOP OF STL (@ L.P.)
+374'-0"
SECTION THROUGH CLASSROOM CORRIDOR FACING NORTHWEST3
A402
SCALE MUST BE USED.
REDUCTION, GRAPHIC
IF DRAWING IS A
CAUTION: 0 5'10' 20'
1/16" = 1'-0"
SECTION FACING SOUTHEAST
1/16" = 1'-0"
1/16" = 1'-0"
1/16" = 1'-0"
1/16" = 1'-0"
A508
A507
SIM.
A610 TYP.
A402
RECORD DRAWING November 14, 2002