A305.pdf

PDF 485 KB Posted

Attached to
Building Masonry Repair at Quantico, Virginia
Solicitation number
15DDHQ18Q00000171
Issued by

About this file

Drawing A305

View the file

Other files

File Type Posted
RFQ_Addendum_0006.pdf PDF
RFQ_15DDHQ18Q00000171_Addendum_0005.pdf PDF
RFQ_15DDHQ18Q00000171_Addendum_0004.pdf PDF
RFQ_15DDHQ18Q00000171_Addendum_0003.pdf PDF
QRFI_Masonry_Repair_Quantico_VA.pdf PDF
A301.pdf PDF
Request_for_Access_Form.pdf PDF
A401.pdf PDF
RFQ_15DDHQ18Q00000171.pdf PDF
A302.pdf PDF
A505.pdf PDF
A303.pdf PDF
A402.pdf PDF
A507.pdf PDF
A503.pdf PDF
A306.pdf PDF
A508.pdf PDF
A512.pdf PDF
A304.pdf PDF
A504.pdf PDF
A502.pdf PDF
A509.pdf PDF
A511.pdf PDF
A513.pdf PDF
A506.pdf PDF
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Washington, D.C. 20009 Comm Number 7782 921A

1875 Connecticut Ave. NW Suite 600

SUPV

SUBMITTED BY

TITLE

CHKDRWN

CH ENGR

408 404 40504B

D/M/YR

D/M/YRAPPROVED

APPROVED

EFD FOR COMMANDER, NAVFAC

D/M/YR

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND

CHESAPEAKE DIVISION, WASHINGTON D.C.

SCALE SPEC SHEET 21-92-0193 OF

SIZE CODE IDENT NO.

Drug Enforcement Administration Justice Training CenterQuantico, Virginia

F 80091 CONSTR. CONTR. NO.

NAVFAC DRWING NUMBER

N62477-92-C-0193

E.I.C. 403 40204

09A 401

LTR

REVISION

DESCRIPTION DATE APPRV'D.

MLM ACH

WMC CFK

CHIEF ARCHITECT

A305

3080617

GRAPHIC 73 329

ENLARGED

EXTERIOR ELEVATIONSSECTOR B

SECTOR A

SECTOR C

KEY PLAN

N

A305

A305

NORTHEAST OFFICE ELEVATION2

A305

4"

9' -4

9' -4

9' -4

GROUND FLOOR

+306'-0"

MEZZANINE FLOOR

+317'-4"

1ST FLOOR

+326'-8"

2ND FLOOR

+336'-0"

3RD FLOOR

+345'-4"

ROOF (L.P.)

+355'-2"

0"

0"

0"

0"

1ST FLR

+322'-0"

2ND FLR

+336'-0"

3RD FLR

+348'-0"

ROOF (L.P.)

+360'-0"

TOP OF STL

+374'-0"

4"

9' -4

9' -4

9' -4

GRND FLR

+306'-0"

MEZZ FLR

+317'-4"

1ST FLR

+326'-8"

2ND FLR

+336'-0"

3RD FLR

+345'-4"

ROOF (L.P.)

+355'-2"

A501

A601

SHT-MET-3

COPING

BR-2

SF-3

BR-2

CMU-5

BR-1

BR-1

CMU-5

BR-2

METAL STAIR

& RAILING

MP-2 MP-2 MP-2

METAL STAIR

& RAILING

BR-1

SHT-MET-3

COPING

BR-2

W-4

BR-2

CMU-5

SHT-MET-3

COPING

BR-1

APC-1

SF-26

APC-1

BR-1

CMU-5

BR-2

SHT-MET-3

COPING

BR-1

SF-20

W-6

GD2D1

22 BC

IN

6'-0"

MASONRY

OPENING

ELEVATION @ DORMITORY STAIR

W-5

1/4" = 1'-0"

5'2'1'0

PERFORATED ALUM. SOFFIT

METAL ROOF

MATERIALS LEGEND:

BRICK 1 (BR-1)

BRICK 2 (BR-2)

NOTES:

1. REFER TO ARCHITECTURAL FLOOR PLANS FOR WINDOW TYPE

DESIGNATIONS AND HORIZONTAL DIMENSIONS AND PLAN DETAILS.

2. REFER TO REFERENCED SECTIONS FOR ADDITIONAL VERTICAL

DIMENSIONS AND SECTIONAL DETAILS.

3. REFER TO MATERIALS LEGENDS FOR APPLICABLE FACE MATERIALS.

RUNNING BOND SOLDIER COURSE BRICK

SEE ELEVATION FOR BRICK TYPE

SPLIT FACED CONC. BLOCK (CMU-5) PRECAST CONC. (APC-1)

CORRUGATED METAL PANEL (MP-1)

METAL PANEL (MP-2)

LOUVER

CAST

STONE

BR-2

(NOTE:

HEADER

COURSE

PATTERN

SHOWN IS

TYPICAL)

BR-2

BR-1

ELEVATION @ DORMITORY STAIR

1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0"

SCALE MUST BE USED.

REDUCTION, GRAPHIC

IF DRAWING IS A

CAUTION:

A506

A506

SF-26

A507

A507

9' -1

0"

9' -1

0"

3A A609

48" HIGH PAINTED METAL

STEEL PLATE SCREEN

SEE

ATTACHED TO HANDRAIL,

RECORD DRAWING November 14, 2002

Model
Layout1

File details come from the government source that posted it.