Attachment J-4
Fire Alarm System Jefferson Laboratories of the FDA
Dated May 28, 2015
(18 Pages)
XX X
X
X
X
X X X X
X
X
X
X
X
X
X
X
X X X X X X
XX XXX
XXX XXX XXX XX
X
XX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXX
X
XXX X XX X X X X X X X X X XX XX X X XX X XX X XXX XXXX XX X XXX XXXX
X X X XXX X X
X
X
X
X
X
X
X
X
X
XX
X
X X X X XX XX X
X
X
X
X
X
X
X
X
X X
X X X X
X X
X X
X XX
X X
XX
X X
X X
X
X
XXXX
X X
X X
XXX X XX XX XXX
X
X
X
X
X
X
X
X
X
T
XXX
X
X
X
X
X
XX XXX XX X X X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XX X X X
X
X
X
X
X
X
X
XX XXX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XXXX XXXX XX X XXX X XX XXX XX
XXXX XX XXX XXXX XXXX XXX XXX X XX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X X
X
X
XXX XXX XXXX X X X
X
X
X
X
X
X
X
X
X
X
XX X X X X X
X
ARL
21 28
20 20
I. OCCUPANCY CLASSIFICATION: (302-312,508) GROUP _____
OCCUPANCY LOAD: (TABLE 1004.1.2) 100 GROSS SF/OCCUPANT
FIRST FLOOR _____SF/100=___ OCCUPANTS
SECOND FLOOR
II. CONSTRUCTION: (TABLE 601) TYPE ____
ALLOWABLE HEIGHT (TABLE 503) 1 STORY
SPRINKLER INCREASE (504.2) 1 STORY
TOTAL ALLOWABLE STORIES: ____ STORIES
ALLOWABLE AREA: (TABLE 503) _____ SF
FRONTAGE INCREASE (506.2) _____ SF
SPRINKLER INCREASE (506.3) _____ SF
TOTAL ALLOWABLE AREA _____ SF
FIRE RESISTENT RATINGS: (TABLE 601 & 602)
STRUCTURAL FRAME 0
FLOOR/ CEILING & ROOF/ CEILING 0
EXTERIOR NON-LOAD BEARING WALLS 0
BEARING WALLS 0
EXIT CORRIDOR WALLS (TABLE 1017.1) 0
SHAFT & STAIR ENCLOSURES (TABLE 1020) 1
PERMANENT PARTITIONS 0
FIRE WALLS 0
III. BUILDING SYSTEMS:
FIRE EXTINGUISHERS: EVERY 3000 SF, OR 75' ALONG EXIT CORRIDOR.
IV. EXIT REQUIREMENTS:
EGRESS WIDTH (TABLE 1005.1)
STAIRS 0.3 INCH/OCCUPANT SERVED
OTHER 0.2 INCH/OCCUPANT SERVED
MINIMUM NUMBER OF EXITS (1019) 2
MINIMUM CLEAR OPENING AT EXITS 32 IN.
EXIT TRAVEL DISTANCE (TABLE 1016.1) ____ FT.
CORRIDOR WIDTH (TABLE 1017.2) ____ IN.
DEAD END CORRIDORS (TABLE 1017.3) ____ FT.
MINIMUM EXITS PER FLOOR (TABLE 1019.1) ___
MINIMUM STAIR WIDTH (1009.1) ___ IN.
HANDRAILS: 34"-38" HIGH, 12" BEYOND TOP AND BOTTOM RISERS.
GUARDRAILS: 42" HIGH, WHERE 30" ABOVE GRADE.
EXIT SIGNS: NO POINT IN CORRIDOR GREATER THAN 100' FROM SIGN
INTERNATIONAL BUILDING CODE 2006 / ARKANSAS 2007
AFPC 2007 CODE DATA CERTIFICATION
"I HEREBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS HAVE BEEN
PREPARED BY ME OR UNDER MY SUPERVISION. I FURTHER CERTIFY THAT, TO
THE BEST OF MY KNOWLEDGE, THESE PLANS AND SPECIFICATIONS ARE AS
REQUIRED BY LOW AND IN COMPLIANCE WITH THE ARKANSAS FIRE PREVENTION
CODE FOR THE STATE OF ARKANSAS."
SHEET INDEX
G1 COVER SHEET
ELECTRICAL
E1 ELECTRICAL LEGEND AND ABBREVIATIONS
E2 ELECTRICAL PLAN 1
E3 ELECTRICAL PLAN II
FIRE PROTECTION
F001 FIRE PROT LEGEND AND NOTES
F5A-1D FIRE ALARM DEMO PLAN - BLDG 5 - A
F5A-1 FIRE PROT PLAN - BLDG 5 - A
F5A-P FIRE PROTECTION PLAN - BLDG 5A PENTHOUSE
F5B1-1 BLDG 5-B1 FIRE PROTECTION PLAN
F5B2-1 BLDG 5-B2 FIRE PROTECTION PLAN
F010 BLDG 5FA - MNS PANEL INTERFACE
F011 BLDG 5 FA - MNS / NAC RISER
F012 BLDG 5 FA - MNS NAC RISER
F013 BLDG 5 FA - MNS AMP RISER
F014 BLDG 5 FA - MNS RISER
F015 BLDG 5 FIRE PROTECTION DETAILS
F016 BLDG 5 FIRE PROTECTION DETAILS
A101
SIM
Name Elevation
DETAIL CALLOUT
(DETAIL #/ SHEET #)
LEVEL MARKER
(LEVEL NAME/ ELEVATION IN FEET)
WALL TAG
(WALL TYPE #)
WINDOW TAG
(WINDOW TYPE #)
DOOR TAG
(DOOR TYPE #)
ROOM NAME AND NUMBER
KEYNOTE
SYMBOL LEGEND
1t
1i
A101
1 1
A101
ELEVATION CALLOUT (MULTIPLE IN A ROOM)
(DETAIL #/ SHEET #)
ELEVATION CALLOUT (SINGLE IN A ROOM)
(DETAIL #/ SHEET #)
Name
XXX
GRID LINEA
ENLARGED DETAIL CALL OUT1
A101
1i SIGNAGE TAG
TOXICOLOGICAL RESEARCH
NCTR/JEFFERSON
EXIT
PINE
BLUFF
JEFFRSON PINE BLUFF
ARSENAL
RIVER
TO FORT SMITH
LITTLE ROCK
TO TEXARKANA
TO MEMPHIS
NATIONAL CENTER FOR
PROJECT LOCATION
AR
KAN
SAS
REDFIELD
HW
Y 365
NORTH LITTLE ROCK40
BUILDING 5A
SITE
62A
45T
LITTLE
TO DALLAS
TEXARKANA
ROCK
PINE
BLUFF
RIVER
FORT SMITH
TO OKLAHOMA CITY
ARKANSAS
40 MEMPHIS
TO
S
T.
L
O U
IS
JEFFERSON, ARKANSAS 72079
SUBMITTED:
STUCK ASSOCIATES ARCHITECTS
DRAWING NO. SHEET:
CHECKED BY:DRAWN BY:DATE:SCALE:
DESCRIPTION BY CHECK
A
B
C
D
E
F
G
H
I
J
K
1 2 3 4 5 6 7 8 9
JEFFERSON LABORATORIES OF THE FDA
FIRE ALARM SYSTEM: 100% DESIGN
R
D
EG
I S
TERE A
T
RCHITEC
STUCK
ASSOCIATES,
PLLC
A SR K A N S A
NO LL-112
As indicated
6/3/2015 3:04:30
PM
100% DESIGN SUBMITTAL
Author05-28-2015
COVER SHEET
BUILDING 5A
G1
Designer
3878.15 /
JEFFERSON LABORATORIES OF THE FDA
BUILDING 5A - FIRE ALARM SYSTEM DESIGN
100% DESIGN SUBMITTAL
3/8" = 1'-0" 1 Project Location Map
1/4" = 1'-0" 2 Site Map
3/8" = 1'-0" 3 State Location Map
100% DESIGN REVIEW SUBMITTAL
SHEET 1 OF 17
05-28-2015
STUCK ASSOCIATES ARCHITECTS
JEFFERSON LABORATORIES OF THE FDA
As indicated S. LACEY05-28-2015
5/28/2015
BUILDING 5A
SWL
1/8" = 1'-0"
A1
Floor Plan
FLOOR PLAN GENERAL NOTES
A All construction shall be in accordance with the requirements of the applicable codes, engineering shall conform to all applicable municipal, state and federal regulation having jurisdiction including accessibility standards and requirements of "Americans with Disabilities Act."
B Each trade is advised that information pertinent to its work may occur in various sections of the contract documents. Refer to every sheet of drawings for notes and symbols. Notes shall be reviewed and applied to related building components regardless of their locations in the drawings and specifications.
C Unless noted otherwise, any note, detail, or feature indicated for one condition shall be applicable for all alike and similar conditions.
D The Contractor shall furnish and install all blocking, stiffeners, bracing, backing plated and supporting brackets required for the proper installation of all building components as recommended by the manufacturer and required by code. In walls, provide blocking attached to studs as backing supports for wall-mounted items.
E All dissimilar metals shall be effectively isolated from each other to avoid molecular breakdown.
F All exterior joints around window and door frames, between walls and founds, between walls and roof, between wall panels, at penetration of utilities through the envelope shall be sealed or weather-stripped to prevent air and moisture leakage/infiltration.
G Finish floor elevations are to the top of concrete, unless noted otherwise.
H Interior partitions are dimensioned to face of stud, unless noted otherwise. Do not scale drawings.
Questions regarding dimensions shall be reported to the Architect.
FLOOR PLAN KEY NOTES
N
LaceyFire Protection Engineering, LLC
JEFFERSON, ARKANSAS 72079
SUBMITTED: DRAWING NO. SHEET:
CHECKED BY:DRAWN BY:DATE:SCALE:
DESCRIPTION BY CHECK
A
B
C
D
E
F
G
H
I
J
K
1 2 3 4 5 6 7 8 9
FIRE ALARM SYSTEM: 100% DESIGN
SHEET__ OF__
FIRE ALARM GENERAL NOTES:
1. FIRE ALARM SYSTEM AND DEVICES SHALL BE INSTALLED TO
CURRENT NFPA 72, NFPA 70, AND LOCAL REQUIREMENTS.
2. ALL FIRE ALARM INSTALLATIONS, INCLUDING PULLING OF WIRE AND
MOUNTING OF DEVICES, SHALL HAVE OVERSIGHT OF A NICET LEVEL II
FIRE ALARM TECHNICIAN OR HIGHER.
3. STROBES SHALL BE SYNCHRONIZED BY CIRCUIT.
4. AS A GENERAL RULE, CONDUIT IS NOT REQUIRED ABOVE CEILINGS
OR IN WALLS. CONDUIT IS REQUIRED TO SLEEVE PENETRATIONS OF
CABLE THROUGH WALLS ABOVE CEILINGS. WATER TIGHT CONDUIT
AND FITTINGS ARE REQUIRED WHERE DEVICES ARE SURFACE
MOUNTED WITHIN ANIMAL HOUSING AREAS AND AS INDICATED. NEW
CONDUIT SHALL BE FACTORY RED DIPPED.
5. SURFACE MOUNTING OF DEVICES IN EXPOSED AREAS SHALL BE
LIMITED UNLESS IT IS NOT POSSIBLE TO GET CONDUCTORS OR BOXES
WITHIN WALLS. ANY SURFACE MOUNTED DEVICES IN FINISHED AREAS
SHALL BE IN COMPATIBLE WIRE MOLD BOXES AND ENCLOSURES
UNLESS INDICATED OTHERWISE. SURFACE MOUNTED DEVICES IN
MECHANICAL ROOMS SHALL BE IN CONDUIT.
6. ANY CABLING BELOW SEVEN FEET OR SUBJECT TO MECHANICAL
DAMAGE SHALL BE IN CONDUIT PER NFPA 70.
7. FPLP CABLE SHALL BE USED AND SECURED IN ACCORDANCE WITH
NFPA 70.
8. THESE DESIGN DOCUMENTS PROVIDE GENERAL SPACING,
LOCATION, CIRCUITING AND COORDINATION CRITERIA. CONTRACTOR
SHALL BE RESPONSIBLE FOR EVALUATING THAT DEVICES TO BE USED
ARE WITHIN THE VOLTAGE AND CURRENT LIMITATIONS CALCULATED.
CONTRACTOR SHALL SUBMIT PRODUCT CUT SHEETS SHOWING THAT
THE DEVICES TO BE INSTALLED ARE WITHIN THE CRITERIA OF THE
DESIGN DOCUMENTS. DOCUMENTS SHALL BE SUBMITTED FOR
REVIEW AND APPROVAL PRIOR TO STARTING CONSTRUCTION.
9. CONTRACTOR IS RESPONSIBLE FOR FIELD COORDINATION, FIELD
CONDITIONS, AND MAKING SLIGHT ADJUSTMENTS AS NECESSARY.
CONTRACTOR SHALL PROVIDE A NICET LEVEL III OR IV TECHNICIAN /
DESIGNER TO OVERSEE AND ASSIST IN COORDINATING WITH FIELD
CONDITIONS TO SATISFY DESIGN CRITERIA.
10. NO FIRE ALARM DOCUMENTS/PLANS SHALL BE USED FOR
INSTALLATION OF THIS SYSTEM UNLESS THEY CONTAIN A REVIEW
AND APPROVAL STAMP FROM LACEY FIRE PROTECTION
ENGINEERING. LACEY FPE, THE OWNER, AND/OR THE LOCAL AHJ HAS
THE AUTHORITY TO STOP ANY WORK UNTIL SUCH PLANS ARE ON SITE
AND IN USE.
11. SEPARATE FIRE ALARM SPECIFICATIONS CONTAIN VERY DETAILED
INFORMATION ABOUT THIS SYSTEM AND SHALL BE FOLLOWED,
ON-SITE AND AVAILABLE DURING ANY CONSTRUCTION.
LOCATION/SPACING
1. IN ACCORDANCE WITH NFPA 72, STROBES MAY BE MORE THAN 15
FEET OFF THE END OF A CORRIDOR WHEN ROOM SPACING CRITERIA
APPLIES USING THE APPROPRIATE CANDELA.
2. DEVICES SHALL BE MEASURED AND CENTRALLY LOCATED IN
CEILINGS WHEREVER POSSIBLE. IF DEVICES CAN NOT BE LOCATED
WHERE INDICATED ON PLANS, CONTRACTOR SHALL VERIFY THAT
SPACING BETWEEN DEVICES, WALLS, AND END OF CORRIDORS ARE
WITHIN THE LIMITATIONS FOR THE CANDELA INDICATED AND
CALCULATED FOR.
3. PROJECT INVOLVES RETROFIT IN EXISTING CEILINGS. MANY OF
THE CEILINGS ARE HARD-LID WITH LIMITED ACCESS OPENINGS.
CONTRACTOR IS RESPONSIBLE TO ENSURE THAT CUTOUTS FOR
BOXES AND PENETRATIONS THROUGH WALLS FOR CONDUIT AND/OR
CABLES ARE CLEANLY MADE JUST LARGE ENOUGH TO
ACCOMMODATE DEVICES AND BE COVERED BY TRIM PLATES.
4. ALL DEVICES SHALL BE INSTALLED WITH BACK BOXES. ALL WIRE
TERMINATIONS SHALL BE IN JUNCTION BOXES AND SHALL USE
SUITABLE FITTINGS TO PROTECT AND SECURE WIRES AND CABLES
ENTERING BOXES.
5. CUTOUTS SHALL BE CLEANLY MADE SO THAT TOUCH-UP PAINTING
IS NOT REQUIRED. IF TOUCH-UP PAINTING IS REQUIRED THE NEW
PAINT / REPAIR SHALL NOT BE OBVIOUS FROM VIEW DUE TO COLOR,
FINISH, TEXTURE. OR OTHER. IF APPEARANCE CAN NOT BE
MATCHED, THAT ENTIRE SECTION OF WALL / CEILING SHALL BE
REPAINTED TO ENSURE NO EVIDENCE OF RETROFIT HAS OCCURRED.
CONTRACTOR IS RESPONSIBLE FOR COSTS ASSOCIATED WITH
REPAIRS AND PAINTING. ALL MATERIALS SHALL BE APPROVED BY
CONTRACT ADMINISTRATOR PRIOR TO USE. MATERIAL MAY REQUIRE
REVIEW BY SAFETY DEPARTMENT PRIOR TO USE.
6. ALL DEVICES SHALL BE LOCATED WHERE THEY CAN BE READILY
SERVICED.
7. ALL AREA SMOKE AND HEAT DETECTORS SHALL BE CEILING
MOUNTED.
8. SMOKE AND HEAT DETECTORS SHALL NOT BE INSTALLED WITHIN 3'
OF AN AIR-SUPPLY OR RETURN GRILL PER MFG CRITERIA AND
APPENDIX "A" OF NFPA 72.
9. EACH POWER BOOSTER PANEL OR FIRE ALARM PANEL SHALL BE
PROTECTED BY A SMOKE / HEAT DETECTOR. WHEN PROVIDED, AREA
DETECTORS WITHIN THE SAME SPACE WILL SATISFY THIS
REQUIREMENT.
10. AIR HANDLER SYSTEMS OVER 2,000 CFM SHALL BE PROVIDED
WITH MEANS TO SHUT DOWN UPON THE DETECTION OF SMOKE.
THESE DETECTORS SHALL NOT INITIATE BUILDING EVACUATION, BUT
RATHER SUPERVISORY ALARMS.
11. DAMPER AND HVAC SMOKE DETECTORS SHALL BE PROVIDED BY
THE FIRE ALARM CONTRACTOR, LISTED WITH THE FIRE ALARM
SYSTEM, AND INCORPORATE ADDRESSABLE MODULES, UNLESS
INDICATED OTHERWISE SUCH AS AREA 5A ENERGY RECOVERY UNITS
WHERE EXISTING DETECTORS MAY BE MONITORED.
PERFORMANCE
1. ALL DETECTION DEVICES SHALL INCLUDE AN
ADDRESSABLE ADDRESS EITHER INTEGRATED WITHIN THE
DEVICE (SMOKE DETECTOR, PULL STATION), OR AS AS
INTEGRATED ACCESSORY WITHIN THE DEVICE MOUNTING
BOX (SEALED RATE COMPENSATION HEAT DETECTOR).
2. ALL SMOKE DETECTORS SHALL BE DUAL FUNCTION
COMBINATION SMOKE AND HEAT DETECTORS. UPON
DETECTION OF SMOKE THEY SHALL PROVIDE A
SUPERVISORY SIGNAL AT THE FACP INDICATING
DETECTION OF SMOKE AND THE LOCATION BY BUILDING
AND ROOM / CORRIDOR. UPON DETECTION OF HEAT THE
DEVICE SHALL INITIATE AN ALARM CONDITION WITH
BUILDING EVACUATION. DEVICES SHALL BE PROGRAMMED
SUCH THAT EVENT CHANGES CAN BE EASILY MADE.
3. DETECTORS INDICATED AS HEAT ONLY SHALL BE RATE
COMPENSATION DEVICES AND SHALL BE SEALED AND
APPROVED FOR WET LOCATIONS. THESE DEVICES SHALL
BE INSTALLED IN BOXES WITH SEALING GASKETS.
SEALING OF THESE DEVICES IN ANIMAL HOUSING AREAS IS
CRITICAL AND SHALL BE APPROVED BY CONTRACT
ADMINISTRATOR PRIOR TO USE. SAMPLES SHALL BE
PROVIDED FOR REVIEW AND APPROVAL. UPON
DETECTION OF HEAT THESE DEVICES SHALL INITIATE AN
ALARM CONDITION AND PROVIDE FOR BUILDING
EVACUATION.
4. SMOKE DETECTORS SHALL NOT BE INSTALLED UNTIL
CLEANUP OF ANY REMODEL DUST SUCH AS FROM
CUTTING IN NEW HOLES.
5. DUCT DETECTORS SHALL BE MONITORED FOR
INTEGRITY AND PROVIDE A SUPERVISORY SIGNAL AT THE
FIRE ALARM PANEL. SOME DUCT DETECTORS WILL SHUT
DOWN THE RESPECTIVE UNITS. HOWEVER, SOME UNIT
DUCT DETECTORS MAY NOT AUTOMATICALLY SHUT DOWN
THE RESPECTIVE UNITS. DUE TO THE NATURE OF THIS
FACILITIES VENTILATION AND EXHAUST SYSTEMS SOME
UNITS MAY REQUIRE UNIQUE CONTROL LOGIC PRIOR TO
AUTOMATIC SHUT DOWN. WHERE SPECIFIC CRITERIA IS
APPLICABLE IT WILL BE INDICATED FOR THE UNIT ON
DRAWINGS.
6. FIRE ALARM AUDIBLE ALERT SIGNALS SHALL BE SET TO
TEMPORAL CODE PER NFPA 72. SOLID PRE-ALERT TONES
WILL BE USED FOR OTHER SIGNALS.
7. UNLESS OTHERWISE NOTED THE FOLLOWING MINIMUM
SURVIVABILITY CRITERIA SHALL BE MEET: SIGNALING LINE
CIRCUITS CLASS "B", AND NOTIFICATION CIRCUITS CLASS
"B".
COMMISSIONING
1. A COMPLETED AND SIGNED RECORD (CERTIFICATE) OF COMPLETION
FORM SHALL BE PROVIDED BY THE CONTRACTOR TO THE CONTRACT
ADMINISTRATOR AND THE ENGINEER PRIOR TO COMMISSION TESTING.
THIS CERTIFICATE SHALL CERTIFY THAT THE CONTRACTOR HAS
PRE-TESTED EVERY DEVICE AND FUNCTION OF THE SYSTEM, ANY
DEFICIENCIES SHALL HAVE BEEN REPAIRED PRIOR TO THE
COMMISSIONING TEST.
2. ALL SMOKE DETECTORS SHALL BE COMMISSIONED USING CANNED
SMOKE OR A METHOD THAT WILL FUNCTIONALLY TEST THE SMOKE
CHAMBER. THE USE OF MAGNETS FOR COMMISSION TESTING OF
SMOKE DETECTORS IS STRICTLY PROHIBITED.
3. EACH AND EVERY DEVICE SHALL BE TESTED DURING
COMMISSIONING AND PRIOR TO BEING TURNED OVER TO THE OWNER.
4. EACH NOTIFICATION CIRCUIT SHALL BE TESTED UNDER
STANDBY/BATTERY POWER. END-OF-LINE VOLTAGE READINGS SHALL
BE TAKEN AND DOCUMENTED PRIOR TO COMMISSION TESTING. ANY
CIRCUIT THAT MEASURES MORE THAN A 4 VOLT DROP FROM SOURCE
TO END OF LINE SHALL BE CONSIDERED AS FAILING THE DESIGN.
NOTE: SOME SYSTEMS INCORPORATING SYNCHRONIZING MODULES
CAN IMPAIR RESULTS. IF THE MODULE CANNOT BE BYPASSED FOR
VOLTAGE READINGS, THE MANUFACTURER SHOULD BE CONTACTED
FOR GUIDANCE. WHEN VOLTAGE CANNOT BE MEASURED, CIRCUIT
WIRE RESISTANCE READINGS AND DEVICE LOAD MAY BE COMPARED
TO DESIGN CALCULATIONS (MAKE SURE CIRCUIT IS REMOVED FROM
POWER SUPPLY WHEN OBTAINING WIRE RESISTANCE). ONLY A
QUALIFIED TECHNICIAN EMPLOYED BY THE INSTALLING CONTRACTOR
SHOULD PERFORM THIS FUNCTION.
5. EACH CIRCUIT'S END-OF-LINE VOLTAGE SHALL BE DOCUMENTED
FOR COMPARISON TO THE DESIGN END-OF-LINE CALCULATIONS.
DEMOLITION
FIRE ALARM LEGEND
PULL STATION
SMOKE DETECTOR
HEAT DETECTOR
OLD STYLE HORN
OLD STYLE HORN W/ OLD
STYLE LIGHT
HORN/STROBE
cd (CANDELLA) INDICATED
FIRE ALARM CONTROL PANEL
DUCT DETECTOR
S = SUPPLY, R = RETURN
SPEAKER/STROBE
cd (CANDELLA) INDICATED
BOOSTER PANELNAC
FACP
SIGNAL LINE
CIRCUIT NUMBER
SPEAKER-WATTAGE
STROBE-CANDELA
DEVICE NUMBER
CIRCUIT NUMBER
PANEL NUMBER
DEVICE INFORMATION
SCOPE OF WORK:
0. BUILDING 5 HAS A MASTER PLAN PROJECT FOR AN ENTIRE NEW FIRE ALARM
SYSTEM. THIS SYSTEM WILL LIKELY BE INSTALLED IN PHASES, SUCH AS A
RENOVATION OF BUILDING AREA 5A TO START WITH. AS SUCH, IT IS IMPORTANT
FOR THE CONTRACTOR TO CAREFULLY REVIEW AND VERIFY THE INTENDED
SCOPE OF WORK PERFORMED UNDER THEIR RESPECTIVE CONTRACT.
1. FIRE ALARM PANEL IS LIMITED TO SIEMENS FIRE FINDER TO MATCH EXISTING
INFRASTRUCTURE, GRAPHICS SYSTEM, AND CAMPUS NETWORK.
2. THIS UPGRADE WILL INCLUDE THE INTEGRATION OF A MASS NOTIFICATION
SYSTEM (MNS) IN ACCORDANCE WITH CRITERIA OUTLINED IN THE 2010 NFPA 72.
VOICE MESSAGING WILL BE USED FOR FIRE EVACUATION AND MNS MESSAGES.
3. IN ACCORDANCE WITH NFPA 72 A SINGLE CLEAR STROBE WILL BE USED FOR
FIRE AND MNS VISUAL ALERTING. EACH STROBE SHALL INCLUDE THE FACTORY
PRINTED WORD "ALERT" ON THE HOUSING.
4. THE VOICE NOTIFICATION SYSTEM SHALL BE PROVIDED BY A CONTROL PANEL
WHICH IS INDEPENDENT FROM THE FIRE ALARM CONTROL PANEL (FACP) AND IS
LISTED TO UL 864 FOR FIRE ALARM SERVICE. ALL NOTIFICATION DEVICES SHALL
BE OF THE SAME MANUFACTURER AS THE VOICE EVACUATION PANEL. THE VOICE
EVACUATION PANEL SHALL BE LISTED FOR BUILDING PAGING AND BACKGROUND
MUSIC INPUTS. SYSTEM SHALL MATCH EXISTING SITE STANDARDS FOR SPARE
PARTS, CONFIGURATION, AND TRAINING.
5. DETAILED CIRCUITING, PANEL SCHEDULES, LOAD CALCULATIONS, AND
FUNCTIONS OF THIS DESIGN ARE BASED ON COOPER WHEELOCK SAFEPATH
PRODUCTS FOR NOTIFICATION. THIS EQUIPMENT IS CROSS LISTED WITH THIRD
PARTY FIRE ALARM SYSTEMS AND WILL FORM THE BASES OF THE SITE
STANDARD INTERIOR BUILDING MASS NOTIFICATION SYSTEM. USE OF ANY
OTHER COMPONENTS WILL REQUIRE COMPLIANCE WITH ALL PERFORMANCE
OBJECTIVES HEREBY DESIGNED AROUND AND REQUIRES COMPATIBLE
INTEGRATION WITH OTHER STANDARDIZED MNS PRODUCTS ON SITE.
SUBSTITUTE PRODUCTS WILL REQUIRE SUBMITTAL OF FULL DESIGN DOCUMENTS
FOR REVIEW AND APPROVAL PRIOR TO ACCEPTANCE.
6. A DEDICATED FIBER OPTIC NETWORK WILL CONNECT EACH BUILDING FACP TO
BUILDING 54 UNDER SEPARATE SCOPE. EACH NETWORK WILL CONSIST OF AT
LEAST TWO DEDICATED FIRE/MNS FIBERS. ADDITIONAL FIBERS WILL BE PULLED
WHERE INDICATED FOR SPARES.
7. FIRE ALARM SIGNALS WILL BE MONITORED AT BUILDING 54 AS THE CAMPUS
HEAD-END. REMOTE ANNUNCIATORS AT BUILDING 21 WILL MONITOR EACH
SYSTEM. OFFSITE REPORTING MAY BE TRANSMITTED TO PINE BLUFF ARSENAL
VIA AN EXISTING MONACO TRANSCEIVER WITHIN BUILDING 54.
REMOTE ANNUNCIATOR OUTSIDE ROOMS
WITH EXISTING SMOKE / HEAT DET.SH
REVIEW NOTE: THIS SYMBOL REPRESENTS
EXISTING ANNUNCIATORS THAT ARE LOCATED
OUTSIDE ROOMS WITH HEAT AND SMOKE
DETECTORS. THESE WILL BE REMOVED AND
COVERED WITH BLANK, SINGLE GANG, STAINLESS
STEEL PLATES. NEW DEVICES WILL PROVIDE
ROOM ID# ON FACP.
SH
FIRE ALARM &
MASS NOTIFICATION LEGEND
CEILING MOUNT 4" SPEAKER (SINGLE SPEAKER)
CEILING MOUNTED MASS NOTIFICATION STROBE. 15
CANDELA UNLESS MARKED OTHERWISE
CEILING MOUNTED MASS NOTIFICATION SPEAKER/ STROBE.
SEE DETAIL. 15 CANDELA EACH UNLESS MARKED
OTHERWISE.
SMOKE DETECTOR (PHOTOELECTRIC) WITH INTEGRATED
THERMAL DETECTOR.
DUCT SMOKE DETECTOR; S=SUPPLY, R=RETURN
MANUAL PULL STATION 48" AFF
FLOW SWITCH MODULE
TAMPER SWITCH MODULE
DOOR HOLD-OPEN MODULE. PROVIDE FIRE ALARM LISTED
HOLD-OPEN ASSY.
RELAY / CONTROL MODULE
ADDRESSABLE FIRE ALARM CONTROL PANEL SURFACE
MOUNTED UNLESS INDICATED OTHERWISE.
REMOTE ANNUNCIATOR FLUSH MOUNT UNLESS INDICATED
OTHERWISE
24 VDC ELECTRIC BELL FOR WATER FLOW; ~9' AFF
MASS NOTIFICATION SYSTEM CONTROL PANEL
WALL MOUNT MASS NOTIFICATION SPEAKER/STROBE AT
~96" TO TOP. 15 CD OR AS INDICATED.
WALL MOUNT MASS NOTIFICATION / FIRE ALARM SPEAKER
AT ~96" TO TOP TO MATCH SPEAKER/STROBES.
MASS NOTIFICATION BOOSTER AMPLIFIER
EXTERNAL HORN SPEAKER WITH VARIABLE OUTPUT
WATTAGES. INITIAL WATTAGE SET AT ~1.9 UNLESS
INDICATED OTHERWISE.
MASS NOTIFICATION STROBE BOOSTER PANEL
LOCAL OPERATOR CONTROL PANEL FOR MASS
NOTIFICATION WITH SWITCHES FOR 8 PRE-RECORDED
MESSAGES. IF USED.
NOTIFICATION APPLIANCE CIRCUIT
HEAT DETECTOR. "WP" INDICATES WEATHERPROOF.
FS
TS
DH
RM
FACP
RAP
ABBREVIATIONS
WP = WEATHERPROOF
S = SURFACE MOUNTED WITH EXPOSED
RACEWAY
EOL = END OF LINE
EX = EXISTING
VISUAL NOTIFICATION ALARM CIRCUIT.
AUDIO NOTIFICATION ALARM CIRCUIT.
FIRE ALARM SIGNAL LINE CIRCUIT.
GENERAL NOTES:
1. EXISTING RACEWAY MAY BE UTILIZED FOR ROUTING OF NEW SYSTEM CIRCUITS.
WHERE THIS ROUTE DIFFERS FROM THAT INDICATED ON THE PLANS, AS BUILD
DRAWINGS ARE TO REFLECT ALL CHANGES.
2. PAINT J BOX COVERS RED.
3. CONDUIT IS REQUIRED IN OPEN/FINISHED AREAS. NO CABLE SHALL BE RUN
EXPOSED. CABLE SHALL BE ABOVE CEILING, IN WALL, OR IN CONDUIT.
4. PAINT CONDUIT IN FINISHED AREAS TO MATCH EXISTING WALLS.
5. COMPRESSION FITTINGS ARE TO BE USED ON EMT CONDUIT.
6. IN CIRCUITING OF SIGNAL LINE CIRCUIT, THE NUMBER OF TAPS IS TO BE MINIMIZED
AND IS TO BE IN ACCORDANCE WITH MFG AND CODE. ADDITIONAL SLC'S MAY BE
REQUIRED FROM WHAT IS SHOWN IN GENERAL CONCEPT.
DEMOLITION FIRE ALARM GENERAL NOTES:
1. FOR EACH RESPECTIVE AREA, ALL EXISTING FIRE ALARM DEVICES ARE TO BE
REMOVED ALONG WITH THEIR CONDUCTORS UNLESS NOTED OTHERWISE.
2. WHERE A DEVICE IS REMOVED AND NOT REPLACED WITH A NEW FIRE ALARM OR MASS
NOTIFICATION DEVICE, THE RACEWAY IS TO BE SEALED AND A FINISHED BLANK STEEL
PLATE IS TO BE PLACED OVER THE EXISTING BACKBOX. SEAL IF IN A WASH DOWN OR
ANIMAL AREA.
3. EXISTING RACEWAY MAY BE REUSED WHERE POSSIBLE.
4. ALL EXISTING CONDUCTORS ARE TO BE REMOVED AND NOT RE-USED AT ANY POINT
OR LOCATION UNLESS SPECIFICALLY NOTED. EXISTING RACEWAY MAY BE REUSED
WHERE POSSIBLE.
5. EXISTING SURFACE RACEWAY, NOT BEING RE-USED, IS TO BE REMOVED AND ALL
HOLES PATCHED, FINISHED OUT AND PAINTED TO MATCH THE EXISTING AREAS.
6. UPON COMPLETION OF THE INSTALLATION, ALL HOLES, DENTS, SCRATCHES ETC, ARE
TO BE PATCHED, FINISHED OUT AND THEN PAINTED TO MATCH THE SURROUNDING AREA.
7. ALL EXISTING AND NEW RACEWAY AND J-BOXES, UTILIZED FOR THE FIRE ALARM
AND/OR MASS NOTIFICATION SYSTEMS ARE TO BE PROPERLY IDENTIFIED.
8. UNLESS NOTIFIED OTHERWISE BY CONTRACTING OFFICER, EACH ROOM IS TO REMAIN
OCCUPIED DURING CONSTRUCTION. CONTRACTOR IS TO COORDINATE ACCESS TO EACH
ROOM, WITH NCTR, FOR INSTALLATION OF SYSTEM.
9. AS MUCH AS POSSIBLE, THE EXISTING SYSTEM IS TO REMAIN IN OPERATION UNTIL THE
NEW SYSTEM IS IN PLACE AND OPERATIONAL. COORDINATE ANY DOWN TIME WITH NCTR.
10. PROVIDE BLANK PLATES AT ALL EXISTING LOCATIONS OF REMOTE INDICATORS NOT
RE-USED.
SIGNAL LINE CIRCUIT ISOLATION MODULE
WP
DESIGN NOTE FOR AREAS "B" AND "C":
1. AREAS "B" AND "C" OF THIS BUILDING HAVE RECEIVED A PREVIOUS FIRE ALARM
UPGRADE WITH AN EST3 SYSTEM. SEE NOTES RELATED TO USE OF EXISTING
NOTIFICATION LOCATIONS.
2. EXISTING NOTIFICATION IN THESE AREAS DOES NOT FULLY COMPLY WITH
CODE. HOWEVER THESE EXISTING LOCATIONS COULD BE RE-USED IF SPEAKERS
ARE USED THAT WILL WORK WITH EXISTING BACK BOXES. ADDITIONAL
SPEAKERS AND STROBES WILL BE REQUIRED FOR FULL COVERAGE TO SATISFY
THE INTENT OF WHAT IS SHOWN IN THESE DRAWINGS FOR A NEW SYSTEM.
3. SOME EXISTING DETECTION DEVICES WILL REMAIN. ENSURE THAT CIRCUITS
TO THESE DEVICES ARE NOT REMOVED OR ARE RE-ROUTED WITH NEW
CONFIGURATION.
4. CIRCUITING ON THESE DRAWINGS IS INTENDED TO SHOW DEVICE ZONES AND
POSSIBLE ROUTING. CONTRACTOR TO EVALUATE FINAL ROUTING OF CIRCUITS
AND TO SUBMIT FINAL SHOP DRAWINGS AND APPROPRIATE CALCULATIONS FOR
REVIEW AND APPROVAL PRIOR TO INSTALLATION.
IMPORTANT = PRE-ALERT TONES:
THE VOICE MESSAGES FOR THIS BUILDING REQUIRE SPECIFIC AND
CUSTOM PRE-ALERT TONES RECORDED AT 400 - 450 HZ. USE OF ANY
TONE HIGHER THAN THIS CAN STRESS OUT RESEARCH ANIMALS.
THE INSTALLING CONTRACTOR WILL BE LIABLE FOR COSTS DUE TO
STRESS / DEATH OF ANY ANIMAL DUE TO FAILURE TO TEST THE
TONE AND GET OWNER APPROVAL OUTSIDE OF THE BUILDING
PRIOR TO INSTALLATION. THUS, DO NOT INSTALL / CONNECT / OR
TEST ANY FIRE ALARM DEVICE UNTIL THE PRE-RECORDED
MESSAGES HAVE BEEN APPROVED. MESSAGES SHALL MATCH
BUILDING 53.
CONTRACTOR INSTALLATION TO BE BASED ON BUILDING 53:
CONTRACTOR SHALL REVIEW INSTALLATION OF SYSTEM IN
BUILDING 53. THIS INCLUDES HOW SPEAKERS, STROBES, AND HEAT
DETECTORS ARE INSTALLED IN ANIMAL AREAS. ALL DEVICES IN
ANIMAL AND WASH DOWN AREAS SHALL BE LISTED FOR WET
LOCATIONS AND INSTALLED PER DETAILS. SOME PICTURES ARE
INCLUDED ON DETAIL SHEETS.
SPECIFICS FOR AREA 5A RENOVATIONS (PLANS DATED MAY 2015):
1. CONTRACTOR IS RESPONSIBLE TO BECOME FAMILIAR WITH ALL DRAWINGS
ISSUED. THE AREA 5A RENOVATION IS PART OF AN OVERALL MASTER PLAN. AS
SUCH, THESE DRAWINGS CONTAIN INFORMATION AND DETAILS RELATED TO
AREA 5A RENOVATION AND OVERALL MASTER PLAN (FUTURE WORK). SHEETS
NOT ASSOCIATED WITH 5A RENOVATION WILL NOT BE ISSUED WITH THAT SCOPE.
2. SOME ITEMS SPECIFICALLY ASSOCIATED WITH THE 5A RENOVATIONS ARE
IDENTIFIED. HOWEVER, THERE MAY BE ADDITIONAL EQUIPMENT / MODULES /
RELAYS / ETC. REQUIRED TO SATISFY OVERALL SYSTEM PERFORMANCE THAT
ARE NOT SHOWN.
3. CONTRACTOR IS TO ENSURE THAT THEY CLEARLY UNDERSTAND THE 5A
RENOVATION SCOPE, WITH ASSOCIATED BID OPTIONS AS IDENTIFIED. PANELS
AND OTHER EQUIPMENT WILL BE LOCATED IN OTHER BUILDING AREAS AND
REQUIRE CIRCUITS TO BE RUN TO AREA 5A. THIS INCLUDES AREAS 5A AND 5B.
4. CHANGE ORDERS WILL NOT BE AUTHORIZED FOR CONTRACTORS FAILURE TO
BECOME COMPLIANT WITH CRITERIA AND INTENT OF CONTRACT SCOPE.
5. CONTRACTOR IS RESPONSIBLE TO ENSURE THAT THE SYSTEM AND EQUIPMENT
INSTALLED UNDER THE 5A RENOVATION WILL SEAMLESSLY INTEGRATE WITH
FUTURE EXPANSIONS AS OUTLINED IN THE CONTRACT DOCUMENTS.
6. THE FOLLOWING ITEMS HAVE BEEN IDENTIFIED AS SPECIFICALLY REQUIRED AS
PART OF THE 5A RENOVATION PROJECT.
6.1. NEW SIEMENS FIRE FINDER NETWORK PANEL WITH FIBER MODULES TO
INTERFACE WITH EXISTING CAMPUS NETWORK. SHALL MATCH SYSTEM IN
BUILDING 53. "FACP-5"
6.2. GRAPHICS PLANS AND PROGRAMMING TO INCORPORATE AND
COMMUNICATE WITH BUILDING 54 GRAPHICS SYSTEM. TO INCLUDE FLOOR
PLANS AND ALL PROGRAMMING TO MATCH EXISTING OPERATION AND
APPEARANCE FOR OPERATORS.
6.3. SYSTEM SHALL REPORT SIGNALS TO BUILDING 21.
6.4. WHEELOCK SAFEPATH PANEL (DO NOT USE THE MNS VERSION WITH 10
SECOND DELAY). "MNS-5"
6.5. ADDRESSABLE SPLITTERS IN "MNS-5" AND "AP5-AB", AND DATA CIRCUIT
6.6. TELEPHONE ZONE CONTROLLER
6.7. VOLUME CONTROLS AND CABINET AT AMPLIFIER PANEL
6.8. VIKING RAD-AMP FOR TELEPHONE INTERFACE
6.9. WHEELOCK 80 WATT AMPLIFIER PANEL - "AP5-AB"
6.10. TWO STROBE NAC PANELS - "MA" AND "MB1" (SYNC MODULES AS REQUIRED)
6.11. ASSOCIATED BATTERY CABINETS AND BATTERIES WITH MFG DATES.
6.12. FIBER OPTIC WITHIN BUILDING FROM FACP TO WHERE EXTERIOR FIBER
ENTERS THE BUILDING. LOCATED IN ROOM 5B-120.
6.13. CONNECTIONS TO FIBER NETWORK AT BUILDING 5 AND BUILDING 54.
EXISTING FIBERS BETWEEN BUILDING 5 AND 54 WILL BE UTILIZED UNLESS
INDICATED OTHERWISE IN SCOPE.
6.14. 120VAC CIRCUITS FOR NEW PANELS AND FOR RAD-AMP. AT LEAST 3
CIRCUITS. SEE ELECTRICAL SHEETS
6.15. SURGE PROTECTION FOR ALL 120VAC CIRCUITS.
6.16. REMOTE ANNUNCIATOR FOR FACP
6.17. CUSTOM PRE-ALERT TONES AT 400 TO 450 HZ AND VOICE MESSAGES TO
MATCH BUILDING 53.
6.18. WIRE TROUGHS / GUTTERS ABOVE EACH GROUP OF PANELS.
6.19. OTHER EQUIPMENT, HARDWARE, MODULES, CIRCUITS, ETC. REQUIRED TO
ENSURE A SYSTEM THAT FULLY SATISFIES DESIGN CRITERIA AND FUTURE
EXPANSION.
6.20. MONITORING OF EXISTING HVAC DUCT DETECTORS IN PENTHOUSE, ALONG
WITH PROVIDING A LOUDSPEAKER IN PENTHOUSE.
7. THERE HAS BEEN PREVIOUS ROUGH-IN OF SOME CONDUIT, BOXES, AND
CIRCUITS IN AREA 5A. UNDER THIS RENOVATION PROJECT THE CONTRACTOR IS
RESPONSIBLE TO PROVIDE, INSTALL, AND COMMISSION ALL EQUIPMENT
INCLUDING SPEAKERS, STROBES, PULL STATIONS, HEAT DETECTORS, PANELS,
ETC. FOR THIS AREA.
8. CONTRACTOR SHALL EVALUATE THE EXISTING CIRCUITS, BACK BOXES, AND
PATHWAYS FOR COMPLIANCE WITH DESIGN INTENT SHOWN. ANY
DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE CONTRACTING
OFFICER / OWNER AGENT.
9. ALL CIRCUITS SHALL BE CLEARLY LABELED AT EACH PANEL AND IN EACH
JUNCTION BOX. THIS INCLUDES EXISTING ROUGHED-IN CIRCUITS NOT
CURRENTLY LABELED, AFTER CONTRACTOR TRACES THEM OUT AND VERIFIES.
10. CONTRACTOR SHALL PROVIDE THE FOLLOWING EXTRA EQUIPMENT, LABOR,
BACKBOX, WIRING, PROGRAMMING, ETC. EQUIPMENT SHALL BE INSTALLED AT
DIRECTION OF OWNER FOR CHANGES OR MISSING DEVICES AND TO AVOID ANY
CHANGE ORDERS. DEVICES NOT USED SHALL BE TURNED OVER TO THE OWNER
AT THE END OF THE PROJECT. EQUIPMENT SHALL MATCH TYPE AND STYLE USED
IN PROJECT.
10.1. FOUR MONITOR/CONTROL/RELAY MODULES.
10.2. ONE LOUDSPEAKER
10.3. THREE HEAT DETECTORS FOR WET LOCATIONS
10.4. TWO SMOKE/HEAT DETECTORS
10.5. TWO SELECTABLE CANDELA STROBES FOR WET LOCATIONS
10.6. TWO SPEAKER/STROBES
10.7. TWO DUCT DETECTORS AND HOUSINGS
JEFFERSON LABORATORIES OF THE FDA
As indicated S. LACEY05-28-2015
5/28/2015
BUILDING 5A
SWL
1/8" = 1'-0"
A1
Floor Plan
FLOOR PLAN GENERAL NOTES
A All construction shall be in accordance with the requirements of the applicable codes, engineering shall conform to all applicable municipal, state and federal regulation having jurisdiction including accessibility standards and requirements of "Americans with Disabilities Act."
B Each trade is advised that information pertinent to its work may occur in various sections of the contract documents. Refer to every sheet of drawings for notes and symbols. Notes shall be reviewed and applied to related building components regardless of their locations in the drawings and specifications.
C Unless noted otherwise, any note, detail, or feature indicated for one condition shall be applicable for all alike and similar conditions.
D The Contractor shall furnish and install all blocking, stiffeners, bracing, backing plated and supporting brackets required for the proper installation of all building components as recommended by the manufacturer and required by code. In walls, provide blocking attached to studs as backing supports for wall-mounted items.
E All dissimilar metals shall be effectively isolated from each other to avoid molecular breakdown.
F All exterior joints around window and door frames, between walls and founds, between walls and roof, between wall panels, at penetration of utilities through the envelope shall be sealed or weather-stripped to prevent air and moisture leakage/infiltration.
G Finish floor elevations are to the top of concrete, unless noted otherwise.
H Interior partitions are dimensioned to face of stud, unless noted otherwise. Do not scale drawings.
Questions regarding dimensions shall be reported to the Architect.
FLOOR PLAN KEY NOTES
N
LaceyFire Protection Engineering, LLC
JEFFERSON, ARKANSAS 72079
SUBMITTED: DRAWING NO. SHEET:
CHECKED BY:DRAWN BY:DATE:SCALE:
DESCRIPTION BY CHECK
A
B
C
D
E
F
G
H
I
J
K
1 2 3 4 5 6 7 8 9
FIRE ALARM SYSTEM: 100% DESIGN
SHEET__ OF__
KEY PLAN
B2 C D
A B1
F A
C P
SIMPLEX (WITH CLOCK)
COORDINATE REMOVAL OF OLD CLOCK LIGHTING CIRCUITS
TO VERIFY THAT CURRENT CONTROL CIRCUITS ARE NOT
GOING THROUGH THIS CABINET.
85"AFF
60"AFF
60"AFF
60"AFF
60"AFF
SIMPLEX
EDWARDS
SIMPLEX
SPRINKLER RISER
ZERO PRESSURE GAUGE
AS NOT IN SERVICE
FS
THIS AREA SERVED BY
SIMPLEX 4005 IN 5B
NO WORKING FIRE ALARM
SYSTEM THIS SIDE
0 10 20 40
HATCHED AREA
RENOVATED UNDER
PREVIOUS PROJECT. NO
DEMO THIS AREA.
M A
T C
H
L I
M A
T C
H
L
I N
E
C
E
F
G
H
J
A
876.564321 5
7.5
JEFFERSON LABORATORIES OF THE FDA
As indicated S. LACEY05-28-2015
5/28/2015
BUILDING 5A
SWL
1/8" = 1'-0"
A1
Floor Plan
FLOOR PLAN GENERAL NOTES
A All construction shall be in accordance with the requirements of the applicable codes, engineering shall conform to all applicable municipal, state and federal regulation having jurisdiction including accessibility standards and requirements of "Americans with Disabilities Act."
B Each trade is advised that information pertinent to its work may occur in various sections of the contract documents. Refer to every sheet of drawings for notes and symbols. Notes shall be reviewed and applied to related building components regardless of their locations in the drawings and specifications.
C Unless noted otherwise, any note, detail, or feature indicated for one condition shall be applicable for all alike and similar conditions.
D The Contractor shall furnish and install all blocking, stiffeners, bracing, backing plated and supporting brackets required for the proper installation of all building components as recommended by the manufacturer and required by code. In walls, provide blocking attached to studs as backing supports for wall-mounted items.
E All dissimilar metals shall be effectively isolated from each other to avoid molecular breakdown.
F All exterior joints around window and door frames, between walls and founds, between walls and roof, between wall panels, at penetration of utilities through the envelope shall be sealed or weather-stripped to prevent air and moisture leakage/infiltration.
G Finish floor elevations are to the top of concrete, unless noted otherwise.
H Interior partitions are dimensioned to face of stud, unless noted otherwise. Do not scale drawings.
Questions regarding dimensions shall be reported to the Architect.
FLOOR PLAN KEY NOTES
N
LaceyFire Protection Engineering, LLC
JEFFERSON, ARKANSAS 72079
SUBMITTED: DRAWING NO. SHEET:
CHECKED BY:DRAWN BY:DATE:SCALE:
DESCRIPTION BY CHECK
A
B
C
D
E
F
G
H
I
J
K
1 2 3 4 5 6 7 8 9
FIRE ALARM SYSTEM: 100% DESIGN
SHEET__ OF__
Unisex
Storage
Procedure
Procedure
Procedure
Procedure
Return Corridor
Return Corridor
Break
101B
General Office
Super. Office
Office
Office
Women's Change
Men's Change
Storage
Hall
Animal Room
Animal Room
Animal Room
Animal Room
Animal Room
Animal Room
Animal Room
Animal Room
Animal Room
Return Corridor
Supply Corridor
138B
Supply Corridor
138A
1 2 3 4 5 6 6.5 7 7.5 8
A
C
E
F
G
H
J
DOCK
CLEAN DOCK VESTIBULE
HALL
CLEAN PROCESS AREA
DIRTY PROCESS AREA
DIRTY DOCK
PROCESS EQUIPMENT
KEY PLAN
B2 C D
A B1
FIRE PROTECTION PLAN - BLDG 5A
1/8"=1'-0"
GENERAL CIRCUITING NOTES:
1. WHERE STROBE AND SPEAKER CIRCUITS ARE RUN TOGETHER, ONLY THE STROBE
CIRCUIT WILL BE INDICATED. WHERE THE SPEAKER CIRCUIT DEPARTS THE COMMON
PATH TO ADDITIONAL LOCATIONS ITS ROUTE WILL BE SO INDICATED.
2. CIRCUITS IN MECHANICAL ROOMS TO BE IN CONDUIT. USE EXISTING RACEWAY
WHERE POSSIBLE. FIRE ALARM JUNCTION COVERS TO BE RED.
3. ALL NEW CONDUIT IS TO BE FACTORY RED DIPPED. PROVIDE RED TAPE AROUND
EXISTING FIRE ALARM CONDUITS TO BE RE-USED, AT INTERVALS OF 10 FEET AND AT
JUNCTION BOXES.
4. PREVIOUS RENOVATION WORK WAS PERFORMED IN AREA 5A THAT INCLUDED
ROUGH-IN OF CONDUIT, BOXES, AND CIRCUIT WIRING. BE SURE TO REVIEW ALL PROJECT
NOTES CAREFULLY.
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WPWP
WP
WP
WP
WP
STROBE EOL
STROBE EOL
RAP
REMOTE ANNUNCIATOR IS TO BE
PROVIDED AT THIS LOCATION UNDER
BASE BID OF AREA 5A RENOVATION.
EXISTING 2 JUNCTION BOXES WITH
COVERS FOR ACCESS TO AREA 5A
CIRCUITS. SLC, STROBE, SPEAKER.
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
WP
EXISTING S-A1 SPEAKER
AND A-1 STROBE CIRCUITS
S-A1 SPEAKER CIRCUIT FROM
S-A1-9 TO CONTINUE
EXISTING
S-A1 SPEAKER CIRCUIT FROM
S-A1-17 AND A-3 STROBE CIRCUIT
EXISTING
S-A1 SPEAKER AND
A-2 & A-3 STROBE CIRCUITS
CONTRACTOR RESPONSIBLE TO
VERIFY THAT CONDUIT SIZING,
BACK-BOX, & JUNCTION BOXES
WILL ACCOMODATE WIRE AND
CIRCUITS INDICATED.
CONTRACTOR SHALL PROVIDE
ACCURATE MARKED UP
AS-BUILT DRAWINGS SHOWNG
EXACT CIRCUIT / CONDUIT
ROUTING.
KEYED NOTE:
WHEN INSTALLING THIS
AREA, PROVIDE JUNCTION
BOX AND PULL SPEAKER
CIRCUIT. DO NOT MOUNT
SPEAKER UNLESS ADVISED
FOLLOWING TESTING OF
SOUND LEVELS.
S A
S
P E
A K
E R
A
S
T R
O B
E
C
I R
C U
I T
S-A1 SPEAKER CIRCUIT
AND A-2 STROBE CIRCUIT
EXISTING S-A1 SPEAKER
ELEC. ROOM
A
A
WP
A-2 STROBE CIRCUIT
S A
S
P E
A K
C
I R
C U
I T
WP
WP
B
KEYED NOTE:
BOX AND WIRING WERE
ORIGINALLY ROUGHED IN
AT KEY NOTE. HOWEVER,
EQUIPMENT BLOCKS THIS
WALL. RELOCATE CIRCUITS
AND PROVIDE DEVICE IN
NEW LOCATION ON SIDE
WALL.
B
WP
WP
WP
WP
WP
S-A1 SPEAKER
CIRCUIT & A-3
STROBE
C
KEYED NOTE:
EXISTING CONDUITS AND
CIRCUITS IN JUNCTION BOX
FOR THIS EXPANSION.
PROVIDE COVER. BOX IN
ATTIC. SHOULD HAVE
CIRCUITS FOR SLC S5A, NAC
A-3, SPEAKER S-A1.
C
BID OPTION 2:
PROCEDURE ROOMS
BID OPTION 1
CHANGE AREA AND
ADMINISTRATION
SPACES
SLC CONDUIT, BOXES, AND
CIRCUITS ARE EXISTING IN
EQUIPMENT AREA.
PROVIDE DEVICES UNDER
THIS SCOPE.
CONDUIT, BOXES, WIRING WITHIN THIS BOUNDARY
SHOULD BE EXISTING FROM PREVIOUS
EQUIPMENT PROJECT. CONTRACTOR TO PROVIDE
ALL DEVICES (SPEAKERS, STROBES, HEAT, PULL,
ETC.) UNDER AREA 5A RENOVATION SCOPE.
WP
WP
WP
WP
WP
WP
WP
WP
WP
KEYED NOTE:
PREVIOUS PROJECT
PROVIDED CONDUIT AND
CIRCUITS TO JUNCTION
BOX WITH COVER FOR
FUTURE EXPANSION.
LOCATED IN ATTIC.
D
D
SPEAKER S-A1 GOES BACK TO ATTIC AND NORTH
ACROSS BUILDING TO DEVICE S-A1-24
FIELD LOCATE #28 IN
MECH PENTHOUSE,
SEE SHEET F5A-P
SEE RISER FOR INSERTION OF
DEVICES IN BID OPTION 2
NEW
STROBE
CRKT A-2
TO A-2-6
DUCT DETECTORS IN PENTHOUSE:
SEE PENTHOUSE DRAWING FOR AIR HANDLER UNITS AND
DUCT DETECTORS IN PENTHOUSE
0 10 20 40
KEYED NOTES RELATED TO PREVIOUS WORK:
THIS INFORMATION IS PROVIDED TO HELP INFORM CONTRACTORS UNDER THIS SCOPE WHAT CRITERIA
WAS REQUIRED UNDER PREVIOUS PROJECTS AND WHAT IS REQUIRED UNDER THIS SCOPE. CONTRACTOR
SHALL VERIFY DURING SITE WALK THROUGH THAT PREVIOUS WORK WAS PERFORMED AS INDICATED.
UNDER AREA 5A RENOVATION (PLANS DATED MAY 2015), NAC PANEL MA & MB1 ALONG WITH AMPLIFIER
PANEL "AP5-AB" SHALL BE LOCATED IN AREA "B" WHERE THIS KEYED NOTE IS LOCATED (BACKSIDE OF AREA
"A" WALL. MAIN FACP AND SAFEPATH VOICE PANEL ARE TO BE LOCATED IN A DIFFERENT AREA OF THE
BUILDING AT GRID LINE 15. SEE OTHER SHEETS.
CIRCUIT A-3 WAS SUPPOSED TO BE PREVIOUSLY PULLED TO THIS JUNCTION BOX FOR WORK UNDER "FA
OPTION 1". WIRING HAS BEEN OBSERVED IN THE ATTIC JUNCTION BOX, BUT VERIFICATION OF ACTUAL
CIRCUIT HAS NOT BEEN PROVIDED.
SPEAKER CIRCUITS DO ROUTE TO / THROUGH THE ATTIC JUNCTION BOX. CONTRACTOR TO VERIFY IF
CIRCUIT MATCHES LAYOUT INDICATED.
HOME-RUN STROBE CIRCUITS BETWEEN THIS JUNCTION BOX AND POWER PANELS MAY REQUIRE 12 AWG.
14 AWG REMAINDER OF CIRCUIT. VERIFY ON RISER DIAGRAMS FOR WIRE SIZE.
BUILDING
AREA "B"
JEFFERSON LABORATORIES OF THE FDA
As indicated S. LACEY05-28-2015
5/28/2015
BUILDING 5A
SWL
1/8" = 1'-0"
A1
Floor Plan
FLOOR PLAN GENERAL NOTES
A All construction shall be in accordance with the requirements of the applicable codes, engineering shall conform to all applicable municipal, state and federal regulation having jurisdiction including accessibility standards and requirements of "Americans with Disabilities Act."
B Each trade is advised that information pertinent to its work may occur in various sections of the contract documents. Refer to every sheet of drawings for notes and symbols. Notes shall be reviewed and applied to related building components regardless of their locations in the drawings and specifications.
C Unless noted otherwise, any note, detail, or feature indicated for one condition shall be applicable for all alike and similar conditions.
D The Contractor shall furnish and install all blocking, stiffeners, bracing, backing plated and supporting brackets required for the proper installation of all building components as recommended by the manufacturer and required by code. In walls, provide blocking attached to studs as backing supports for wall-mounted items.
E All dissimilar metals shall be effectively isolated from each other to avoid molecular breakdown.
F All exterior joints around window and door frames, between walls and founds, between walls and roof, between wall panels, at penetration of utilities through the envelope shall be sealed or weather-stripped to prevent air and moisture leakage/infiltration.
G Finish floor elevations are to the top of concrete, unless noted otherwise.
H Interior partitions are dimensioned to face of stud, unless noted otherwise. Do not scale drawings.
Questions regarding dimensions shall be reported to the Architect.
FLOOR PLAN KEY NOTES
N
LaceyFire Protection Engineering, LLC
JEFFERSON, ARKANSAS 72079
SUBMITTED: DRAWING NO. SHEET:
CHECKED BY:DRAWN BY:DATE:SCALE:
DESCRIPTION BY CHECK
A
B
C
D
E
F
G
H
I
J
K
1 2 3 4 5 6 7 8 9
FIRE ALARM SYSTEM: 100% DESIGN
SHEET__ OF__
KEY PLAN
B2 C D
A B1
FIRE PROTECTION PLAN - BLDG 5A PENTHOUSE
1/8"=1'-0"
0 10 20 40
1 2 3 4 5
A
B
C
D
E
F
G
14/14 ø
14/14 ø
8ø
8ø
8ø ø
8ø
14/14
32/32 ø
12ø
8ø
14/14
22ø
8ø
8ø
14/14 ø
8ø
M.17
22ø
6 7 8
FIELD LOCATE FROM
CIRCUIT BELOW
FIELD LOCATE FROM
CIRCUIT BELOW
DUCT DETECTORS IN PENTHOUSE:
AS PART OF AREA 5A RENOVATION, CONTRACTOR TO
PROVIDE MONITOR MODULE IN PENTHOUSE TO
MONITOR EXISTING DUCT DETECTORS. NEW
DETECTORS ARE NOT REQUIRED. FIELD EVALUATE
FOR NUMBER OF MODULES REQUIRED AND
LOCATIONS. ANTICIPATE AT LEAST 9 (THREE FOR
EACH AHU).
JEFFERSON LABORATORIES OF THE FDA
As indicated S. LACEY05-28-2015
5/28/2015
BUILDING 5A
SWL
1/8" = 1'-0"
A1
Floor Plan
FLOOR PLAN GENERAL NOTES
A All construction shall be in accordance with the requirements of the applicable codes, engineering shall conform to all applicable municipal, state and federal regulation having jurisdiction including accessibility standards and requirements of "Americans with Disabilities Act."
B Each trade is advised that information pertinent to its work may occur in various sections of the contract documents. Refer to every sheet of drawings for notes and symbols. Notes shall be reviewed and applied to related building components regardless of their locations in the drawings and specifications.
C Unless noted otherwise, any note, detail, or feature indicated for one condition shall be applicable for all alike and similar conditions.
D The Contractor shall furnish and install all blocking, stiffeners, bracing, backing plated and supporting brackets required for the proper installation of all building components as recommended by the manufacturer and required by code. In walls, provide blocking attached to studs as backing supports for wall-mounted items.
E All dissimilar metals shall be effectively isolated from each other to avoid molecular breakdown.
F All exterior joints around window and door frames, between walls and founds, between walls and roof, between wall panels, at penetration of utilities through the envelope shall be sealed or weather-stripped to prevent air and moisture leakage/infiltration.
G Finish floor elevations are to the top of concrete, unless noted otherwise.
H Interior partitions are dimensioned to face of stud, unless noted otherwise. Do not scale drawings.
Questions regarding dimensions shall be reported to the Architect.
FLOOR PLAN KEY NOTES
N
LaceyFire Protection Engineering, LLC
JEFFERSON, ARKANSAS 72079
SUBMITTED: DRAWING NO. SHEET:
CHECKED BY:DRAWN BY:DATE:SCALE:
DESCRIPTION BY CHECK
A
B
C
D
E
F
G
H
I
J
K
1 2 3 4 5 6 7 8 9
FIRE ALARM SYSTEM: 100% DESIGN
SHEET__ OF__
KEY PLAN
B2 C D
A B1
PHOTOTOX
AHU
AHU-5B1
AHU-5B2
P
P
P
P
P
2 X 4 GRID
2 X 4 GRID
G
I D
I D
I D
I D
2 X 4 GRID
2 X 4 GRID
STROBE EOL
STROBE EOL
SCB1 EOL
STROBE NAC PANEL
FOR AREA "MA"
AUDIO AMPLIFIER "AP5-AB"
STROBE NAC PANEL
FOR AREA B "MB1"
CIRCUIT SHOWN OUTSIDE FOR CLARITY ONLY
SECOND GROUP OF
PANELS LOCATED IN
AREA SHOWN ABOVE.
FIRST GROUP OF PANELS
LOCATED AT GRID 15.
SCB1 DEVICES IN THIS BOUNDARY TO BE
PROVIDED UNDER AREA 5A RENOVATION
GENERAL CIRCUITING NOTES:
1. WHERE STROBE AND SPEAKER CIRCUITS ARE RUN TOGETHER, ONLY THE STROBE
CIRCUIT WILL BE INDICATED. WHERE THE SPEAKER CIRCUIT DEPARTS THE COMMON
PATH TO ADDITIONAL LOCATIONS ITS ROUTE WILL BE SO INDICATED.
2. CIRCUITS IN MECHANICAL ROOMS TO BE IN CONDUIT. USE EXISTING RACEWAY
WHERE POSSIBLE. FIRE ALARM JUNCTION COVERS TO BE RED.
3. ALL NEW CONDUIT TO BE FACTORY RED DIPPED. EXISTING CONDUIT REUSED TO HAVE
RED TAP BANDS AT 10 FOOT INTERVALS.
0 10 20 40
10 11 1
5B-157
B
A
5B-160
5B-161
5B-180
5B-170
5B-100d
5B-151
5B-152
5B-153
5B-154
5B-155
5B-156 150j
5B-150
150g 150d 150a
150h 150e 150b
150i 150f 150c
5B-100f
5B-158
M A
T C
H
L
I N
JEFFERSON LABORATORIES OF THE FDA
As indicated S. LACEY05-28-2015
5/28/2015
BUILDING 5A
SWL
1/8" = 1'-0"
A1
Floor Plan
FLOOR PLAN GENERAL NOTES
A All construction shall be in accordance with the requirements of the applicable codes, engineering shall conform to all applicable municipal, state and federal regulation having jurisdiction including accessibility standards and requirements of "Americans with Disabilities Act."
B Each trade is advised that information pertinent to its work may occur in various sections of the contract documents. Refer to every sheet of drawings for notes and symbols. Notes shall be reviewed and applied to related building components regardless of their locations in the drawings and specifications.
C Unless noted otherwise, any note, detail, or feature indicated for one condition shall be applicable for all alike and similar conditions.
D The Contractor shall furnish and install all blocking, stiffeners, bracing, backing plated and supporting brackets required for the proper installation of all building components as recommended by the manufacturer and required by code. In walls, provide blocking attached to studs as backing supports for wall-mounted items.
E All dissimilar metals shall be effectively isolated from each other to avoid molecular breakdown.
F All exterior joints around window and door frames, between walls and founds, between walls and roof, between wall panels, at penetration of utilities through the envelope shall be sealed or weather-stripped to prevent air and moisture leakage/infiltration.
G Finish floor elevations are to the top of concrete, unless noted otherwise.
H Interior partitions are dimensioned to face of stud, unless noted otherwise. Do not scale drawings.
Questions regarding dimensions shall be reported to the Architect.
FLOOR PLAN KEY NOTES
N
LaceyFire Protection Engineering, LLC
JEFFERSON, ARKANSAS 72079
SUBMITTED: DRAWING NO. SHEET:
CHECKED BY:DRAWN BY:DATE:SCALE:
DESCRIPTION BY CHECK
A
B
C
D
E
F
G
H
I
J
K
1 2 3 4 5 6 7 8 9
FIRE ALARM SYSTEM: 100% DESIGN
SHEET__ OF__
KEY PLAN
B2 C D
A B1
AHU
STROBE EOL
STROBE EOL
STROBE EOL
STROBE EOL
SPEAKER EOL
SCB2 EOL
FACP
SAFEPATH PANEL "MNS-5"
NAC PANEL MB2
CIRCUITS LOCATED FOR
CLARITY (RUN INSIDE BLDG)
AMP "AP5-CD"
NAC MC, MCD, & MD
SECOND GROUP OF PANELS
LOCATED IN AREA SHOWN
ABOVE. FIRST GROUP OF
PANELS LOCATED AT GRID 15.
FIRST GROUP OF PANELS IS LOCATED ABOVE. SECOND
GROUP TO BE LOCATED AT GRID 8. THIRD AT 21.
CONTRACTOR RESPONSIBLE TO
VERIFY THAT CONDUIT SIZING,
BACK-BOX, & JUNCTION BOXES
WILL ACCOMODATE WIRE AND
CIRCUITS INDICATED.
FACP HEAT
APPROX LOCATION OF
EXISTING FIBER CABINET
KEYED NOTES:
UNDER FLOOR DETECTOR. COORDINATE PRECISE LOCATION ON JOB SITE.
LARGE DUCT IS LOCATED DIRECTLY ABOVE PANELS. PROVIDE WIRE TROUGH THAT WILL
ALLOW CONDUITS TO DROP INTO TROUGH TO SIDE OF DUCT AND WIRES TO BE ROUTED
OVER CONDUITS DROPPING DOWN TO PANELS.
COORDINATE EXACT PANEL CONFIGURATION. STACK ABOVE/BELOW AS NECESSARY.
GENERAL CIRCUITING NOTES:
1. WHERE STROBE AND SPEAKER CIRCUITS ARE RUN TOGETHER, ONLY THE STROBE
CIRCUIT WILL BE INDICATED. WHERE THE SPEAKER CIRCUIT DEPARTS THE COMMON
PATH TO ADDITIONAL LOCATIONS ITS ROUTE WILL BE SO INDICATED.
2. CIRCUITS IN MECHANICAL ROOMS TO BE IN CONDUIT. USE EXISTING RACEWAY
WHERE POSSIBLE. FIRE ALARM JUNCTION COVERS TO BE RED.
PNLS
'MD'
'MCD'
'MC'
'AP5-CD'
AMP "AP5-CD"
SEE ENLARGED PANEL
DETAIL THIS SHEET
PROVIDE WIRE TROUGH
ABOVE PANELS FOR CONDUIT
ENTRANCE
CONSTRUCT FREE-STANDING WALL / RACK FROM
UNISTRUT OR EQUAL TO SUPPORT PANELS ON
CONCRETE CURB UNDER DUCT AND OUT FROM
WALL. DO NOT BLOCK DUCT ACCESS DOOR.
ENLARGED VIEW
OF MECHANICAL
ROOM AND PANEL
LOCATIONS IN
ROOM 5B-117
BELOW GRADE
SHELTER AREA
SPEAKER-HORNS REQUIRED FOR
VOICE COVERAGE WHERE
SPEAKER-HORNS ARE SHOWN.
0 10 20 40
70" WIDE RACK, ~69"
TALL, LOCATE 25"
OUT FROM WALL
ELECTRICAL PANEL BC-1
PROVIDE FOR 100' 2-PAIR FIBER OPTIC CABLE AND
MATERIALS TO BE RAN WITHIN AREA 5B-120
BETWEEN FIBER OPTIC TERMINAL CABINET AND FIRE
ALARM CONTROL PANEL. FIELD COORDINATE EXACT
LOCATION AND ROUTING.
19 20 21
5B-105 5B-104 5B-103 5B-102 5B-101
5B-106
5B-106B
5B-107K 5B-107E 5B-107C 5B-102A
5B-106C 5B-107I 5B-107
5B-121D 5B-106E 5B-106D 5B-107H
5B-107F 5B-107D 5B-107B 5B-107A
B
B
5B-121B
5B-121A 5B-121C
B
5B-108C 5B-108B 5B-108A
5B-108
5B-108D 5B-108E 5B-108F 5B-108H
5B-108G
5B-109C
5B-109D
5B-109
5B-109A
5B-109B
5B-100
B
5B-130
5B-110
5B-111
5B-113
5B-112
5B-119 5B-118H
5B-118 5B-118A
5B-118G 5B-118B
5B-118F 5B-118C
5B-118E 5B-118D
5B-100B
5B-100A
5B-120
58-5BNA 5BNB
58-5BN
RAMP UP
5B-117
5B-116
5B-B00
B00A
B
A
B
G
5B-120B
12 13
5B-149 5B-148
5B-120A
M A
T C
H
L
I N
E
M A
T C
H
L
I N
E
M A
T C
H
L
I N
E M
A T
C H
L
I N
E
ELEC
THESE DETAILS ARE NOT ASSOCIATED
WITH BUILDING 5A RENOVATION SCOPE
THESE PANELS TO BE PROVIDED
UNDER AREA 5A RENOVATION
JEFFERSON LABORATORIES OF THE FDA
As indicated S. LACEY05-28-2015
5/28/2015
BUILDING 5A
SWL
1/8" = 1'-0"
A1
Floor Plan
FLOOR PLAN GENERAL NOTES
A All construction shall be in accordance with the requirements of the applicable codes, engineering shall conform to all applicable municipal, state and federal regulation having jurisdiction including accessibility standards and requirements of "Americans with Disabilities Act."
B Each trade is advised that information pertinent to its work may occur in various sections of the contract documents. Refer to every sheet of drawings for notes and symbols. Notes shall be reviewed and applied to related building components regardless of their locations in the drawings and specifications.
C Unless noted otherwise, any note, detail, or feature indicated for one condition shall be applicable for all alike and similar conditions.
D The Contractor shall furnish and install all blocking, stiffeners, bracing, backing plated and supporting brackets required for the proper installation of all building components as recommended by the manufacturer and required by code. In walls, provide blocking attached to studs as backing supports for wall-mounted items.
E All dissimilar metals shall be effectively isolated from each other to avoid molecular breakdown.
F All exterior joints around window and door frames, between walls and founds, between walls and roof, between wall panels, at penetration of utilities through the envelope shall be sealed or weather-stripped to prevent air and moisture leakage/infiltration.
G Finish floor elevations are to the top of concrete, unless noted otherwise.
H Interior partitions are dimensioned to face of stud, unless noted otherwise. Do not scale drawings.
Questions regarding dimensions shall be reported to the Architect.
FLOOR PLAN KEY NOTES
N
LaceyFire Protection Engineering, LLC
JEFFERSON, ARKANSAS 72079
SUBMITTED: DRAWING NO. SHEET:
CHECKED BY:DRAWN BY:DATE:SCALE:
DESCRIPTION BY CHECK
A
B
C
D
E
F
G
H
I
J
K
1 2 3 4 5 6 7 8 9
FIRE ALARM SYSTEM: 100% DESIGN
SHEET__ OF__
THIS DETAIL SHOWS AN OVERVIEW OF VARIOUS PANELS AND COMPONENTS REQUIRED
FOR A COMPLETE SYSTEM AND AN OVERVIEW OF HOW THEY WILL INTERACT WITH EACH
OTHER. CONTRACTOR IS RESPONSIBLE TO VERIFY EXACT CONFIGURATION AND
SETTINGS OF EACH PIECE OF EQUIPMENT AS MANUFACTURERS MAY MODIFY
EQUIPMENT AND VARIOUS MANUFACTURERS MAY INCORPORATE FEATURES
DIFFERENTLY. SPECIFICATIONS AND OTHER PLAN NOTES MAY PROVIDE ADDITIONAL
CRITERIA.
SUPPORT COMPONENTS SHOULD BE LOCATED WITH PRIMARY PANEL IT IS SUPPORTING
UNLESS NOTED OTHERWISE. BATTERY CALCULATIONS SHALL ESTABLISH FINAL
BATTERY AND POWER REQUIREMENTS FOR EACH PANEL.
NO MORE THAN 3 APPLIANCE PANELS, OR 15 AMP 120VAC LISTED LOAD WHICHEVER IS
LARGER SHALL BE FED FROM A SINGLE 20 AMP 120 VAC CIRCUIT. PROVIDE ADDITIONAL
CIRCUITS WHEN REQUIRED.
SUPERVISION BETWEEN COMPONENTS SHALL BE PROVIDED IN ACCORDANCE WITH
NFPA 72. SUPPLEMENTAL COMPONENTS NOT REQUIRED FOR FIRE EVACUATION OR
REQUIRED FOR MNS DO NOT REQUIRE CIRCUIT SUPERVISION PER NFPA 72.
120VAC CIRCUIT USED FOR RAD-AMP PHONE PAGE PORT SHALL NOT BE ON THE SAME
CIRCUIT AS THE FIRE ALARM PANELS, INCLUDING NAC AND AMPLIFIERS.
120-VAC
DEDICATED
CIRCUIT PER
NFPA 72
TELEPHONE
INTERFACE
FACP "FACP-5"
TROUBLE INPUT FROM
VOICE / MNS PANEL
120-VAC
DEDICATED
CIRCUIT PER
NFPA 72
CLASS "B" SLC LOOP
MESSAGE PRIORITIZATION:
PER CODE MNS SIGNALS OF SELECT
CONTENT CAN OVERRIDE FIRE ALARM
SIGNALS. CAREFUL CONSIDERATION MUST
BE GIVEN TO WHICH MNS HAS HIGHER
PRIORITY OVER FIRE EVACUATION. THIS IS
USUALLY BASED ON LOCAL RISK ANALYSIS.
LOCAL MIC ALLOWS OVERRIDE OF ANY
PRE-RECORDED MESSAGE.
WITH PANEL SHOWN, HIGHER PRIORITY IS
GIVEN TO LOWEST NUMBER, OR TOP SWITCH
#1. THE FOLLOWING IS A…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .