04_140R2024R0017_Part3_of_18_0004.pdf

PDF 37 MB Posted

Attached to
Arroyo Canal Fish Screen/Sack Dam Fish Passage
Solicitation number
140R2024R0017
Issued by

About this file

This file appears to be associated with the Arroyo Canal Fish Screen/Sack Dam Fish Passage solicitation, but I am unable to access or view the actual contents of the PDF file "04_140R2024R0017_Part3_of_18_0004.pdf". Without being able to read the file contents, I cannot provide a meaningful summary of its specific details. The only information available is that it is Part 3 of 18 parts related to solicitation number 140R2024R0017 from the Bureau of Reclamation for improving operations at the Arroyo Canal Fish Screen/Sack Dam Fish Passage Project.

View the file

Other files

File Type Posted
07_140R2024R0017_Section_L__0007.pdf PDF
Sol_140R2024R0017_Amd_0007.pdf PDF
Sol_140R2024R0017_Amd_0006.pdf PDF
06_140R2024R0017_Section_M_0006.pdf PDF
05_140R2024R0017_Part18_of_18_missing_pages_0005.pdf PDF
Sol_140R2024R0017_Amd_0005.pdf PDF
04_140R2024R0017_Part16_of_18_0004.pdf PDF
04_140R2024R0017_Part9_of_18_0004.pdf PDF
04_140R2024R0017_Part12_of_18_0004.pdf PDF
04_140R2024R0017_Part15_of_18_0004.pdf PDF
04_140R2024R0017_Part10_of_18_0004.pdf PDF
04_140R2024R0017_Part1_of_18_0004.pdf PDF
04_140R2024R0017_Part4_of_18_0004.pdf PDF
04_140R2024R0017_Part7_of_18_0004.pdf PDF
04_140R2024R0017_Part14_of_18_0004.pdf PDF
04_140R2024R0017_Part11_of_18_0004.pdf PDF
Sol_140R2024R0017_Amd_0004.pdf PDF
04_140R2024R0017_Part18_of_18_0004.pdf PDF
04_140R2024R0017_Part2_of_18_0004.pdf PDF
04_140R2024R0017_Part13_of_18_0004.pdf PDF
04_140R2024R0017_Part8_of_18_0004.pdf PDF
04_140R2024R0017_Part5_of_18_0004.pdf PDF
04_140R2024R0017_Part6_of_18_0004.pdf PDF
04_140R2024R0017_Part17_of_18_0004.pdf PDF
03_140R2024R0017_7_of_19_0003.pdf PDF
03_140R2024R0017_19_of_19_0003.pdf PDF
03_140R2024R0017_11_of_19_0003.pdf PDF
03_140R2024R0017_8_of_19_0003.pdf PDF
Sol_140R2024R0017_Amd_0003.pdf PDF
03_140R2024R0017_1_of_19_0003.pdf PDF
03_140R2024R0017_14_of_19_0003.pdf PDF
03_140R2024R0017_5_of_19_0003.pdf PDF
03_140R2024R0017_9_of_19_0003.pdf PDF
03_140R2024R0017_3_of_19_0003.pdf PDF
03_140R2024R0017_12_of_19_0003.pdf PDF
03_140R2024R0017_10_of_19_0003.pdf PDF
03_140R2024R0017_4_of_19_0003.pdf PDF
03_140R2024R0017_15_of_19_0003.pdf PDF
03_140R2024R0017_13_of_19_0003.pdf PDF
03_140R2024R0017_18_of_19_0003.pdf PDF
03_140R2024R0017_17_of_19_0003.pdf PDF
03_140R2024R0017_6_of_19_0003.pdf PDF
03_140R2024R0017_2_of_19_0003.pdf PDF
03_140R2024R0017_16_of_19_0003.pdf PDF
02_140R2024R0017_14_of_15_0002.pdf PDF
02_140R2024R0017_9_of_15_0002.pdf PDF
02_140R2024R0017_1_of_15_0002.pdf PDF
02_140R2024R0017_6_of_15_0002.pdf PDF
02_140R2024R0017_8_of_15_0002.pdf PDF
Sol_140R2024R0017_Amd_0002.pdf PDF
Show 40 more

Latest 50 of 70 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Digitally signed by RYAN STEPHEN Date: 2024.03.12 08:03:14 -06'00'

WSEL SETPOINT CONTROL INITIATION, GATE OVERSHOOT CHECK, AND GATE OPENING SEQUENCE

Is the upstream WSEL above the WSEL setpoint deadband?

YES

Is gate A above its maximum setpoint deadband or FULL OPEN?

Is gate A below its minimum setpoint deadband or FULL CLOSED?

YES

Open gate A to GATE_A_MIN

NO

Utilize gate A, go to 2

YES

Calculate the pulse length. [PULSE]

YESNO

NO

YES

NO

Utilize gate B, go to 2

YES

NO Utilize gate A (primary) and gate B (secondary), go to 3

YES

NO

Utilize gate C, go to 2

YES

NO Utilize gate B (primary) and gate C (secondary), go to 3

YES

NO

Utilize gate D, go to 2

YES

NO Utilize gate C (primary) and gate D (secondary), go to 3

YES

NO

Utilize gate E, go to 2

YES

NO Utilize gate D (primary) and gate E (secondary), go to 3

YES

NO

Utilize gate F, go to 2

YES

NO Utilize gate E (primary) and gate F (secondary), go to 3

YES

NO

Utilize gate G, go to 2

YES

NO Utilize gate F (primary) and gate G (secondary), go to 3

YES

NO

Utilize gate H, go to 2

NO Utilize gate G (primary) and gate H (secondary), go to 3

YES

Alarm

Read all variables.

Is gate A moved flagged?

[GATE_A_MOVED = 1]?

NO

NO

NO

NO

NO

NO

NO

NO

YES

YES

YES

YES

YES

YES

YES

YES

Utilize gate A, go to 7

Utilize gate B, go to 7

Utilize gate C, go to 7

Utilize gate D, go to 7

Utilize gate E, go to 7

Utilize gate F, go to 7

Utilize gate G, go to 7

Utilize gate H, go to 7

Start automatic operation and initialize feedback and operational variables to default state.

Is gate B moved flagged?

[GATE_B_MOVED = 1]?

Is gate C moved flagged?

[GATE_C_MOVED = 1]?

Is gate D moved flagged?

[GATE_D_MOVED = 1]?

Is gate E moved flagged?

[GATE_E_MOVED = 1]?

Is gate F moved flagged?

[GATE_F_MOVED = 1]?

Is gate G moved flagged?

[GATE_G_MOVED = 1]?

Is gate H moved flagged?

[GATE_H_MOVED = 1]?

Is gate B above its maximum setpoint deadband or FULL OPEN?

Is gate C above its maximum setpoint deadband or FULL OPEN?

Is gate D above its maximum setpoint deadband or FULL OPEN?

Is gate E above its maximum setpoint deadband or FULL OPEN?

Is gate F above its maximum setpoint deadband or FULL OPEN?

Is gate G above its maximum setpoint deadband or FULL OPEN?

Is gate H above its maximum setpoint deadband or FULL OPEN?

Is gate B below its minimum setpoint deadband or FULL CLOSED?

Is gate C below its minimum setpoint deadband or FULL CLOSED?

Is gate D below its minimum setpoint deadband or FULL CLOSED?

Is gate E below its minimum setpoint deadband or FULL CLOSED?

Is gate F below its minimum setpoint deadband or FULL CLOSED?

Is gate G below its minimum setpoint deadband or FULL CLOSED?

Is gate H below its minimum setpoint deadband or FULL CLOSED?

A

LW

A Y

S T

H

IN

K S

A F

E T

Y

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

.0

S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

4- D

-6

R

IV

ER

B

YP

A S S G

A

TE

C O

N

TR

O

LS

S H

EE

T

1.

D

W G

LA

S T

S A V

ED

D A

TE

-0 3-

LA

S T

S A V

ED

B Y

V M

IL

LA

N A G

U

IL

A R

C

EN

TR

A L

V A

LL

EY

P

R O

JE

C T

S A N

J O

A Q

U

IN

R

IV

ER

R

ES

TO

R A

TI

O N

P R O

G R A M

S A C K D

A M

B

YP

A S S

R

IV

ER

B

YP

A S S

RIVER BYPASS GATE

CONTROLS

BLOCK DIAGRAM

DENVER, CO

214-D-60388

2024-02-26

REFERENCE DRAWINGS

RIVER BYPASS GATE CONTROL BLOCK DIAGRAM

(SHEET 2) 423-D-60389

RIVER BYPASS GATE CONTROL BLOCK DIAGRAM

(SHEET 3) 423-D-60390

NOTES

1. These diagrams are is intended to show only general operation and not intended to be a direct representation of the required system programming. Additional requirements are provided in the supplied Specification. Detailed control implementation and user interface design shall be performed by the Contractor.

2. Logic shall check if a gate is available prior to making any gate adjustments. A gate shall be considered unavailable if it is locked out by an operator, in alarm status, or if it is unable to communicate with the PLC.

3. If a gate is unavailable, logic shall skip the unavailable gate from the gate sequence and alarm that the gate is unavailable.

4. Variables shown are not a comprehensive list of all variables required in program.

5. The '#' symbol in variables shall be replaced with a letter corresponding to the gate sequence position it is associated with (i.e. GATE_A_POS is for the gate position transducer reading from gate A).

6. The '$' symbol in variables shall be replaced with a tag name corresponding to the gate it is associated with (i.e.

GATE_OG310_MAX_DB is the maximum gate opening setpoint for gate 001-OG-310).

7. All variables shall be settable from the OIT.

8. The control system shall allow the operator to assign, on the

OIT, the sequence that the control system will open the gates. The river bypass gates (001-OG-310, 001-SG-320, 001-SG-330, etc.) shall be assignable to Gate A, Gate B, Gate C, Gate D, Gate E, Gate F, Gate G, and gate H, in the gate opening sequence.

FLOWCHART LOCATIONS

REFERENCE

NUMBER

DESTINATION

REFERENCE

DRAWING

214-D-60388

214-D-60390

214-D-60390

214-D-60390

214-D-60390

214-D-60389

214-D-60390

EXPLANATION

VARIABLE DESCRIPTION

GATE_$_MULT Operator entered gate adjustment factor with specific variables for each gate. Variable used for adjusting gate response to account for different gate widths.

GATE_#_MOVED Flag that is set for a specific gate that is being moved. Used to check and correct if a gate exceeded or is exceeding its maximum and minimum setpoints.

PULSE Calculated pulse within a maximum pulse length (PULSE_MAX) and minimum pulse length

(PULSE_MIN).

PULSE_MAX Operator entered maximum pulse length setpoint representing the maximum pulse length used when calculating a pulse for raising or lowering a gate.

PULSE_MIN Operator entered minimum pulse length setpoint representing the minimum pulse length used when calculating a pulse for raising or lowering a gate.

WSEL_SET Operator entered upstream water surface level setpoint.

WSEL_SET_DB WSEL setpoint deadband.

WSEL_UPSTREAM This variable shall represent the value feedback from level sensor LE-302 or LE-305.

GATE_MOVED_TIMER Delay timer for the operator entered delay between pulsing the gate open or closed.

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER -

V. MILLAN-AGUILAR

A. WOODRUFF

L. GENTRY

L. GENTRY, P.E.

ELECTRICAL CONTROLS GM

E. MORLEY, P.E.

Fractional Horsepower Motor Rated Disconnect Snap Switch

Dedicated GFI Receptacle

Fused Disconnect Switch, size and type indicated in schedule

Electrical Panel

GFI Receptacle

Transformer

Automatic Transfer Switch

Electrical Connection

Motor Starter, size and type indicated in schedule

Fractional HP Motor Toggle Switch

Light Switch 3-way

M

F

T

ATS

to

PB

Exit Sign Light with Emergency Egress Lights

Emergency Egress Light

Wall Pack Luminaraire

Wall Pack Luminaire

Linear Strip Luminaire

Detail

Power Pole

Pull Box

Equipment Tag

Conduit Stub Up

Motor

D: Dedicated Circuit

M: Motor Rated

FACP: Fire Alarm Control Panel

WP: Weather Proof

FVR: Full Voltage Reversing

AFG: Above Full Grade

TBD: To Be Determined

MLO: Main Lug Only

C Loads: Coincidental Loads

NC Loads: Non-Coincidental Loads

UNO: Unless Noted Otherwise

RMC: Rigid Metal Conduit

PVC: Polyvinyl Chloride

SCH: Schedule

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

4- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 2-

LA

S T

S A V

ED

B Y

C W

IE

R Z B A N

O W

S K I

C

EN

TR

A L

V A

LL

EY

P

R O

JE

C T

S A N

J O

A Q

U

IN

R

IV

ER

R

ES

TO

R A

TI

O N

P R O

G R A M

S A C K D

A M

B

YP

A S S

LEGEND, INDEX,

POWER CABLE &

CONDUIT

SCHEDULE

DENVER, CO

214-D-60394

2024-02-26

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

D Johnson, P.E.

C Wierzbanowski

L Billy

Mendlin, Eric T P.E.

Kelly, John T P.E.

Electrical Engineer

ELECTRICAL DRAWINGS

LEGEND, INDEX, POWER CABLE & CONDUIT

SCHEDULE 214-D-60394

CONTROLS CABLE & CONDUIT SCHEDULE 214-D-60395

UNDERGROUND CONDUIT SITE PLAN 214-D-60396

POWER SITE PLAN 214-D-60397

MAINTENANCE BUILDING EQUIPMENT LAYOUT

PLAN VIEW 214-D-60398

MAINTENANCE BUILDING POWER ELEVATION 214-D-60399

MAINTENANCE BUILDING LIGHTING PLAN VIEW 214-D-60400

MAINTENANCE BUILDING LIGHTING ELEVATION 214-D-60401

DK1 AND DK4 PANEL SCHEDULES AND LAYOUT 214-D-60402

DK2 PANEL SCHEDULE AND LAYOUT 214-D-60403

MAIN SINGLE LINE DIAGRAM 214-D-60404

EQUIPMENT GROUNDING DIAGRAM 214-D-60405

GROUNDING GRID PLAN VIEW AND

UNDERGROUND LAYOUT 214-D-60406

GROUNDING GRID PLAN VIEW AND LAYOUT 214-D-60408

D1A, D1B, D2A, D2B PANEL SCHEDULES 214-D-60409

L1A, L2B, DK3 PANEL SCHEDULES 214-D-60410

EQUIPMENT CONNECTION SCHEDULE 214-D-60411

SYMBOLS LEGEND

POWER CABLE AND CONDUIT SCHEDULE

CONDUIT

NUMBER

CONDUIT SIZE

-TYPE CONDUCTORS ORIGIN DESTINATION NOTES

1 BY PG&E BY PG&E PG&E XFMR Meter Box Conduit by utility

2 2 1/2" - RMC 3-1/C 3/0AWG + 3/0AWG-N + 6AWG-G Meter Box MSD

3 2 1/2" - RMC 3-1/C 3/0AWG + 3/0AWG-N + 6AWG-G MSD D1A

4 2" - RMC 3-1/C 1AWG + 1AWG-N + 8AWG-G D1A ATS

5 2" - PVC SCH 80 3-1/C 1AWG + 1AWG-N + 8AWG-G Generator ATS Elbows are RMC.

6 3/4" - RMC 3-1/C 8AWG + 8AWG-N + 10AWG-G Generator Load Bank

7 1" - RMC 3-1/C 6 + 6AWG-N + 10AWG-G D1A SPD

8 3/4" - RMC 3-1/C 12AWG + 12AWG-G D1A K1A

9 3/4" - RMC 3-1/C 12AWG + 12AWG-G D1A K1B

10 3/4" - PVC SCH 80 3-1/C 8AWG + 10AWG-G D1A D1B PVC when Buried. RMC when exposed. Elbows are RMC.

11 3/4" - PVC SCH 80 2-1/C 10AWG + 10AWG-G D1A DK1 PVC when Buried. RMC when exposed. Elbows are RMC.

12 3/4" - PVC SCH 80 2-1/C 12AWG + 12AWG-G D1A DK2 Elbows are RMC.

13 3/4" - PVC SCH 80 3-1/C 12AWG + 12AWG-G D1A Air Burst Compressor Equip Tag 1 Elbows are RMC.

14 3/4" - RMC 3-1/C 12AWG + 12AWG-N + 12AWG-G K1A L1A

15 3/4" - RMC 3-1/C 10AWG + 10AWG-N + 10AWG-G K1B L1B

16 2" - RMC 3-1/C 1AWG + 1AWG-N + 8AWG-G ATS D2A

17 2" - PVC SCH 80 3-1/C 1AWG + 1AWG-N + 8AWG-G D2A D2B PVC when Buried. RMC when exposed. Elbows are RMC.

18 3/4" - RMC 2-1/C 12AWG + 12AWG-G D2A DK3

19 1" - PVC SCH 80 3-1/C 10AWG + 10AWG-G D2A

Fish Screen Brush Cleaner Motor

Control Panel Equip Tag 3 Elbows are RMC.

20 3/4" - RMC 3-1/C 10AWG + 10AWG-G D1B

Fish Screen Monorail Hoist Receptacles

Equip Tag 6

21 1" - PVC SCH 80 (Future) D1B Fish Ladder Trash Rake (future) Elbows are RMC.

22 3/4" - RMC 2-1/C 12AWG + 12AWG-G D2B DK4

23A 3{2"-PVC SCH 80} 3 x {9-1/C 12AWG + 3-1/C 12AWG-G} D2B Pull Box A Elbows are RMC.

23B 2" - RMC 9-1/C 12AWG + 3-1/C 12AWG-G Pull Box A Pull Box B Embedded in concrete.

23C 2" - RMC 9-1/C 12AWG + 3-1/C 12AWG-G Pull Box A Pull Box C Embedded in concrete.

23D 2" - RMC 9-1/C 12AWG + 3-1/C 12AWG-G Pull Box A Pull Box D Embedded in concrete.

24 3/4" - RMC 3-1/C 12AWG + 12AWG-G Pull Box B Headworks 4.5' Slide Gate #1 Embedded in concrete.

25 3/4" - RMC 3-1/C 12AWG + 12AWG-G Pull Box B Headworks 4.5' Slide Gate #2 Embedded in concrete.

26 3/4" - RMC 3-1/C 12AWG + 12AWG-G Pull Box B Headworks 10' Slide Gate #1 Embedded in concrete.

27 3/4" - RMC 3-1/C 12AWG + 12AWG-G Pull Box B Headworks 10' Slide Gate #2 Embedded in concrete.

28 3/4" - RMC 3-1/C 12AWG + 12AWG-G Pull Box C Headworks 10' Slide Gate #3 Embedded in concrete.

29 3/4" - RMC 3-1/C 12AWG + 12AWG-G Pull Box C Headworks 10' Slide Gate #4 Embedded in concrete.

30 3/4" - RMC 3-1/C 12AWG + 12AWG-G Pull Box C Headworks 10' Overshot Gate Hoist #1 Embedded in concrete.

31 3/4" - RMC 3-1/C 12AWG + 12AWG-G Pull Box C Headworks 10' Overshot Gate Hoist #2 Embedded in concrete.

32 3/4" - RMC 3-1/C 12AWG + 12AWG-G Pull Box D Fish Ramp 4.5' Slide Gate #1 Embedded in concrete.

33 3/4" - RMC 3-1/C 12AWG + 12AWG-G Pull Box D Fish Ramp 4.5' Slide Gate #2 Embedded in concrete.

34 3/4" - RMC 3-1/C 12AWG + 12AWG-G Pull Box D Fish Ramp 4.5' Slide Gate #3 Embedded in concrete.

35 3/4" - RMC 3-1/C 12AWG + 12AWG-G Pull Box D Fish Ramp 4.5' Slide Gate #4 Embedded in concrete.

36 3/4" - RMC 2-1/C 10AWG + 10AWG-G DK1 Rectifier Equipment Tag 28 At Headworks equipment pad

37 3/4" - RMC 2-1/C 12AWG + 12AWG-G DK1 120V Receptacle At Headworks equipment pad

38 3/4" - RMC 2-1/C 10AWG + 10AWG-G DK2 Rectifier Equipment Tag 27 At Fish Screen equipment pad.

39 3/4" - RMC 2-1/C 12AWG + 12AWG-G DK2 120V Receptacle At Fish Screen equipment pad.

40 3/4" - PVC SCH 80 2-1/C 12AWG + 12AWG-G DK3 001-CP-101 Equip. Tag 31 Elbows are RMC.

41 3/4" - PVC SCH 80 2-1/C 12AWG + 12AWG-G DK3 001-CP-102 Equip. Tag 32 Elbows are RMC.

42 3/4" - PVC SCH 80 2-1/C 12AWG + 12AWG-G DK3 001-CP-103 Equip. Tag 33 Elbows are RMC.

43 3/4" - RMC 2-1/C 12AWG + 12AWG-G DK3 001-CP-001 Equip. Tag 29

44 3/4" - RMC 2-1/C 12AWG + 12AWG-G DK3 001-CP-002 Equip. Tag 30

45 3/4" - RMC 2-1/C 12AWG + 12AWG-G DK4 001-CP-301 Equip. Tag 34

46 3/4" - RMC 2-1/C 12AWG + 12AWG-G DK4 001-CP-302 Equip. Tag 35

47 3/4" - RMC 3-1/C 10AWG + 10AWG-G L1A Heat Pump Outdoor Unit (HP-1) Tag 22

48 3/4" - RMC 3-1/C 10AWG + 10AWG-G L1A Heat Pump Outdoor Unit (HP-2) Tag 23

49 3/4" - RMC 2-1/C 12AWG + 12AWG-G L1A Booster Pump (BPS-1) Equip Tag 26

50 3/4" - PVC SCH 80 2-1/C 12AWG + 12AWG-G L1A Septic Alarm Panel Equip Tag 9 Elbows are RMC.

51 3/4" - RMC 2-1/C 12AWG + 12AWG-G L1B Bathroom Exhaust Fan (EF-1) Tag 24

52 3/4" - RMC 2-1/C 12AWG + 12AWG-G L1B FACP Equip Tag 26

53 3/4" - RMC 2-1/C 12AWG + 12AWG-G L1B Receptacles Exterior Building Multiple instances

54 3/4" - RMC 2-1/C 12AWG + 12AWG-G L1B Lighting Exterior Building Multiple instances

55 3/4" - RMC 2-1/C 12AWG + 12AWG-G L1B Receptacles Rm. 100 & 101 Multiple instances

56 3/4" - RMC 2-1/C 12AWG + 12AWG-G L1B Receptacles Rm. 100 & 101 Multiple instances

57 3/4" - RMC 2-1/C 12AWG + 12AWG-G L1B Receptacles Rm. 100 & 102 Multiple instances

58 3/4" - RMC 2-1/C 12AWG + 12AWG-G L1B Lighting Rm. 100, 101, 101A, 102 Multiple instances

59 3/4" - PVC SCH 80 2-1/C 12AWG + 12AWG-G L1B GenSet Battery Heater Rm. 104 Elbows are RMC.

60 3/4" - PVC SCH 80 2-1/C 12AWG + 12AWG-G L1B GenSet Coolant Heater Rm. 104 Elbows are RMC.

61 3/4" - PVC SCH 80 2-1/C 12AWG + 12AWG-G L1B GenSet Battery Charger Rm. 104 Elbows are RMC.

62 3/4" - PVC SCH 80 2 x 6AWG Anode Rectifier Equipment Tag 28 North Rectifier Junction Box North side of Fish Screen. Elbows are RMC.

63 3/4" - PVC SCH 80 2 x 6AWG Anode Rectifier Equipment Tag 27 South Rectifier Junction Box South side of Fish Screen. Elbows are RMC.

ABBREVIATIONS

R

EV

N O

-0 2-

D

M en dl in

Er ic T

P .E

U pd at ed s ch ed ul e an d sc he du le n ot es

Re le as ed

M Maintenance Building

Tower

Note 2

Note 8

Note 3

Note 9

Fence

Note 6

Note 7

Note 5

Note 3

Fi sh

S cr ee n

Note 4

27 31

M

S

Note 4

PB PB

REFERENCE DRAWINGS

LEGEND, INDEX, POWER CABLE & CONDUIT

SCHEDULE 214-D-60394

CONTROLS CABLE & CONDUIT SCHEDULE 214-D-60395

MAINTENANCE BUILDING POWER ELEVATION 214-D-60399

MAINTENANCE BUILDING LIGHTING PLAN VIEW 214-D-60400

DK1 AND DK4 PANEL SCHEDULES AND LAYOUT 214-D-60402

DK2 PANEL SCHEDULE AND LAYOUT 214-D-60403

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

D Johnson, P.E.

C Wierzbanowski

L Billy

Mendlin, Eric T P.E.

Kelly, John T P.E.

Electrical Engineer

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

4- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 2-

LA

S T

S A V

ED

B Y

C W

IE

R Z B A N

O W

S K I

C

EN

TR

A L

V A

LL

EY

P

R O

JE

C T

S A N

J O

A Q

U

IN

R

IV

ER

R

ES

TO

R A

TI

O N

P R O

G R A M

A R R O

YO

C

A N

A L

FI

S H

S C R

EE

N

UNDERGROUND

CONDUIT

SITE PLAN

DENVER, CO

214-D-60396

2024-02-26

SITE PLAN - POWER

1" = 100'

NOTES

1. All conduit buried 24" below finished grade unless otherwise noted.

2. New electric meter refer to drawing 214-D-60400.

3. SCADA conduit 67, space 6" from power conduits on fish screen.

4. Conduit 10, 11, & 17. When on fish screen power conduit 6" above handrail and 6" below kickout.

5. Power conduit 38-41 offset 12" from SCADA conduit 66.

6. Pull box, sized by Contractor, qty (2), one for SCADA circuits, one for power circuits.

7. Fish Screen concrete pad, refer to drawing 214-D-60403 for equipment layout.

8. Underground service entrance feeder offset 5' from building foundation.

9. Proposed new PG&E pole-mount transformer and new power pole.

10. Rectifier Junction Box to be mounted on Fish Screen. Refer to drawing 214-D-60416 notes for location.

R

EV

N O

-0 2-

D

M en dl in

Er ic T

P .E

U pd at ed n ot es a nd c on du it nu m be rs

Re le as

Note 5

Note 3

Note 2

Note 4

Fi sh

S cr ee n

Fishramp

River Bypass

F

WP F

WP F

WP

F

WP

F

WP

F

WP

F

WP

F

WP

F

WP F

WP F

WP F

WP

Note 8

Note 4 Note 12

Note 6

Note 5

Note 7

23A

PB

PB

PB

PB

PB

PB

PB

Note 9

Note 10

Note 11

REFERENCE DRAWINGS

LEGEND, INDEX, POWER CABLE & CONDUIT

SCHEDULE 214-D-60394

CONTROLS CABLE & CONDUIT SCHEDULE 214-D-60395

DK1 AND DK4 PANEL SCHEDULES AND LAYOUT 214-D-60402

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

D Johnson, P.E.

C Wierzbanowski

L Billy

Mendlin, Eric T P.E.

Kelly, John T P.E.

Electrical Engineer

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

4- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 2-

LA

S T

S A V

ED

B Y

C W

IE

R Z B A N

O W

S K I

C

EN

TR

A L

V A

LL

EY

P

R O

JE

C T

S A N

J O

A Q

U

IN

R

IV

ER

R

ES

TO

R A

TI

O N

P R O

G R A M

S A C K D

A M

B

YP

A S S

POWER

SITE PLAN

DENVER, CO

214-D-60397

2024-02-26

SITE PLAN - POWER

1" = 100'

NOTES

1. All conduit buried 24" below finished grade unless otherwise noted.

2. SCADA conduits 75-77 from drawing 214-D-60395.

3. River bypass concrete pad, refer to drawing 214-D-60402 for equipment layout.

4. Conduit 10, 11, 17. When on fish screen, mount 6" above handrail and 6" below kickout.

5. Offset SCADA conduit 67 12" horizontally from power at headworks and space 6" from power conduits on fish screen.

6. Pull box, sized by Contractor, qty (2), one for SCADA circuits, one for power circuits.

7. SCADA pull box, sized by Contractor. Power pull box A sized according to specifications.

8. Power conduits 23B/C/D from drawing 214-D-60394. Route conduits within 18" offset from handrail on traffic deck side.

9. Pull box B takes conduit 23B and splits cables into conduits 24-27.

10. Pull box C takes conduit 23C and splits cables into conduits 28-31.

11. Pull Box D takes conduit 23D and splits cables into conduits 32-35.

12. Contractor to determine SCADA and power circuit conduit routes to actuator for connection. Refer to drawing 60295 for actuator location.

13. Rectifier Junction Box to be mounted on Fish Screen. Refer to drawing 214-D-60416 notes for location.

R

EV

N O

-0 2-

D

M en dl in

Er ic T

P .E

U pd at ed n ot es

Re le as

DCBA

STORAGE

GENERATOR

ENCLOSURE

MECH

102ARESTROOM

D2AK1B

L1B

D1A K1A

L1A

ATS

MSD

M METER

CABINET

F

WP

F

WP

F

WP WP

M

T

T WP

to

Battery Charger

Jacket Heater

22 23

CP-001

F

WP

FACP

CP-002

3WP

10 11 12

DK3

CONTROL

ROOM

Coolant Heater

REFERENCE DRAWINGS

LEGEND, INDEX, POWER CABLE & CONDUIT

SCHEDULE 214-D-60394

MAINTENANCE BUILDING POWER ELEVATION 214-D-60399

MECHANICAL MAINTENANCE BUILDING HVAC

PLAN 214-D-60287

AIR BURST CLEANING SYSTEM PLAN 214-D-60321

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL

D Johnson, P.E.

C Wierzbanowski

L Billy

Mendlin, Eric T P.E.

Kelly, John T P.E.

Electrical Engineer

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

4- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 2-

LA

S T

S A V

ED

B Y

EM

EN

D

LI

N

C

EN

TR

A L

V A

LL

EY

P

R O

JE

C T

S A N

J O

A Q

U

IN

R

IV

ER

R

ES

TO

R A

TI

O N

P R O

G R A M

A R R O

YO

C

A N

A L

FI

S H

S C R

EE

N

M A

IN

TE

N

A N

C E

B U

IL

D

IN

G

EQUIPMENT LAYOUT

PLAN VIEW

DENVER, CO

214-D-60398

2024-02-26

POWER PLAN

1/4" = 1'0"

NOTES

1. Drawings show approximate locations of mechanical and electrical equipment.

2. Number shown next to device is circuit number of L1B, unless noted otherwise.

3. Control panel side of EG set is facing the Maintenance building.

D

A

C

B

Re le as

3 2 1

NOTES

1. Concrete pad to go beneath outdoor wall mounted equipment.

2. Exterior mounted wall pack light fixture. Bottom at

10'-0 above finished grade.

3. Main service rated fused disconnect with locking provision, placed adjacent to and within sight of meter and not more than 10' away. Approximate dimensions: 28.94" high x 17.02" wide x 8.51" deep.

Handle shall not be more than 6-7' above finished grade.

4. Maintain working clearances for meter panels and service equipment each: 30" wide x 36" deep x 75" high.

5. PG&E Service Conduit (in the center position).

Contractor to provide riser conduit that extends from the conduit bend out of ground and into the electrical meter panel.

6. Bused, safety-socket meter box for self-contained metering. Ring type, USERC compliant with PG&E approved test by pass facilities and test block.

REFERENCE DRAWINGS

LEGEND, INDEX, POWER CABLE & CONDUIT

SCHEDULE 214-D-60395

MAINTENANCE BUILDING EQUIPMENT LAYOUT

PLAN VIEW 214-D-60398

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

D Johnson, P.E.

C Wierzbanowski

L Billy

Mendlin, Eric T P.E.

Kelly, John T P.E.

Electrical Engineer

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

4- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 2-

LA

S T

S A V

ED

B Y

EM

EN

D

LI

N

C

EN

TR

A L

V A

LL

EY

P

R O

JE

C T

S A N

J O

A Q

U

IN

R

IV

ER

R

ES

TO

R A

TI

O N

P R O

G R A M

A R R O

YO

C

A N

A L

FI

S H

S C R

EE

N

M A

IN

TE

N

A N

C E

B U

IL

D

IN

G

POWER

ELEVATION

DENVER, CO

214-D-60399

2024-02-26

EAST ELEVATION

3/8" = 1'-0"

Note 2

Note 3

Note 4 Note 5

Note 6

Re le as

X1

WP1

WP1

WP1

WP1

LS1LS1

LS1 LS1

LS1

LS1

LS1

LS1

W1

W2

X1

EM1

EM1

L1B

WP14

2 2 2

2 2 2

DCBA

CONTROL ROOM

STORAGE

GENERATOR

ENCLOSURE

MECH

102A

RESTROOM

W2

WP14

REFERENCE DRAWINGS

LEGEND, INDEX, POWER CABLE & CONDUIT

SCHEDULE 214-D-60394

MAINTENANCE BUILDING LIGHTING ELEVATION 214-D-60401

L1A, L2B, DK3 PANEL SCHEDULES 214-D-60410

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

D Johnson, P.E.

L Billy

J. Kelly

Mendlin, Eric T P.E.

Kelly, John T P.E.

Electrical Engineer

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

4- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 2-

LA

S T

S A V

ED

B Y

EM

EN

D

LI

N

C

EN

TR

A L

V A

LL

EY

P

R O

JE

C T

S A N

J O

A Q

U

IN

R

IV

ER

R

ES

TO

R A

TI

O N

P R O

G R A M

A R R O

YO

C

A N

A L

FI

S H

S C R

EE

N

M A

IN

TE

N

A N

C E

B U

IL

D

IN

G

LIGHTING

PLAN VIEW

DENVER, CO

214-D-60400

2024-02-26

LIGHTING FIXTURE SCHEDULE

Type Manufacturer / Model Catalog Number Voltage

(Volts) Mounting Description

LS1 Lithonia Z Series ZLID L48 5000LM MVOLT 50K 90CRI 120 Pendant Linear Strip LED

W1 Lithonia WL2 Series WL2 12L EZ1 LP835 MSD7 120 Wall Wall Light 2'

W2 Lithonia WL4 Series WL4 20L EZ1 LP835 MSD7 120 Wall Wall Light 4'

WP1 Lithonia WDGE2 Series WDGE2 LED P3 27K 70CRI T3M MVOLT PIR1FC3V 120 Exterior Wall Wall Pack

X1 Lithonia LHQM LED LHQM LED R 120 Wall Exit Sign Emergency Egress with

Light

EM1

Lithonia ELM4L LED Emergency

Light ELM4L 120 Doors Emergency Egress Interior

LIGHTING PLAN

3/8" = 1'0"

NOTES

1. Lights not to scale.

2. Light locations estimated.

3. Exterior lights will have integrated motion sensor.

4. Provide unswitched hotleg to exit sign lights and emergency egress lights.

5. Number next to luminaire is circuit number of panelboard

L1B.

Re le as

D C B A

WP1 bottom at

9'-0" AFG

100A

WP1 bottom at

9'-0" AFG

WP1 bottom at

11'-0" AFG

100B

DCBA

WP1 bottom at

9'-0" AFG

WP1 bottom at

9'-0" AFG

REFERENCE DRAWINGS

LEGEND, INDEX, POWER CABLE & CONDUIT

SCHEDULE 214-D-60394

MAINTENANCE BUILDING POWER ELEVATION 214-D-60399

MAINTENANCE BUILDING LIGHTING PLAN VIEW 214-D-60400

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

D Johnson, P.E.

L Billy

J. Kelly

Mendlin, Eric T P.E.

Kelly, John T P.E.

Electrical Engineer

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

4- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 2-

LA

S T

S A V

ED

B Y

EM

EN

D

LI

N

C

EN

TR

A L

V A

LL

EY

P

R O

JE

C T

S A N

J O

A Q

U

IN

R

IV

ER

R

ES

TO

R A

TI

O N

P R O

G R A M

A R R O

YO

C

A N

A L

FI

S H

S C R

EE

N

M A

IN

TE

N

A N

C E

B U

IL

D

IN

G

LIGHTING

ELEVATION

DENVER, CO

214-D-60401

2024-02-26

EAST ELEVATION VIEW - SEE DRAWING 214-D-60399

3/16" = 1'-0"

NORTH ELEVATION VIEW

3/16" = 1'-0"

WEST ELEVATION VIEW

3/16" = 1'-0"

SOUTH ELEVATION VIEW

3/16" = 1'-0"

Re le as

Rectifier

DK1

DK1-1

DK4 D1B

CP-301 CP-302

D 2B

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

D Johnson, P.E.

C Wierzbanowski

L Billy

Mendlin, Eric T P.E.

Kelly, John T P.E.

Electrical Engineer

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

4- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 2-

LA

S T

S A V

ED

B Y

EM

EN

D

LI

N

C

EN

TR

A L

V A

LL

EY

P

R O

JE

C T

S A N

J O

A Q

U

IN

R

IV

ER

R

ES

TO

R A

TI

O N

P R O

G R A M

S A C K D

A M

B

YP

A S S

DK1 AND DK4

PANEL SCHEDULES AND

LAYOUT

DENVER, CO

214-D-60402

2024-02-26

3/4" = 1'-0" 14' W x 10' L River Bypass Concrete Pad

EXPLANATION

DEVICE LOCATION DESCRIPTION

CP-301 River Bypass Concrete Pad

001-CP-301 Headworks PLC Cabinet (120V)

CP-302 River Bypass Concrete Pad

001-CP-302 Level Sensors Controllers (120V)

D1B River Bypass Concrete Pad 480V Panelboard

D2B River Bypass Concrete Pad 480V Panelboard

DK1 River Bypass Concrete Pad

5KVA Transformer Load Center (480-240/120V)

DK4 River Bypass Concrete Pad

2KVA Transformer Load Center (480-240/120V)

REFERENCE DRAWINGS

POWER SITE PLAN 214-D-60397

MAIN SINGLE LINE DIAGRAM 214-D-60404

EQUIPMENT GROUNDING DIAGRAM 214-D-60405

ELECTRICAL EQUIPMENT SUPPORT, TYPE 1

SECTIONS AND DETAIL 40-D-60001

NOTES

1. Refer to 214-D-60397 for concrete pad location.

2. DK1-1 refers to the receptacle load connected to the 1st circuit of transformer load center DK1.

3. Dashed lines show minimum required panelboard working clearances.

Re le as

CP-101 CP-102

CP-103

DK2-3

DK2

R ec tif ie r

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

D Johnson, P.E.

C Wierzbanowski

L Billy

Mendlin, Eric T P.E.

Kelly, John T P.E.

Electrical Engineer

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

4- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 2-

LA

S T

S A V

ED

B Y

EM

EN

D

LI

N

C

EN

TR

A L

V A

LL

EY

P

R O

JE

C T

S A N

J O

A Q

U

IN

R

IV

ER

R

ES

TO

R A

TI

O N

P R O

G R A M

A R R O

YO

C

A N

A L

FI

S H

S C R

EE

N

FI

S H

S C R

EE

N

DK2

PANEL SCHEDULE AND

LAYOUT

DENVER, CO

214-D-60403

2024-02-26

3/8" = 1'-0" 12'W x 8'L Fish Screen Concrete Pad

EXPLANATION

DEVICE LOCATION DESCRIPTION

DK2 Fish Screen Concrete Pad

Transformer Load Center (480-240/120V)

CP-101 Fish Screen Concrete Pad

001-CP-101 Fish Screen PLC Cabinet (120V)

CP-102 Fish Screen Concrete Pad

001-CP-102 Fish Screen Relay Cabinet (120V)

CP-103 Fish Screen Concrete Pad

Level Sensor Controllers (120V)

NOTES

1. Refer to 214-D-60396 for concrete pad location.

2. DK2-3 refers to the receptacle load connected to the 3rd circuit of transformer load center DK2.

3. Dashed lines show minimum required panelboard working clearances.

REFERENCE DRAWINGS

LEGEND, INDEX, POWER CABLE & CONDUIT

SCHEDULE 214-D-60394

UNDERGROUND CONDUIT SITE PLAN 214-D-60396

ELECTRICAL EQUIPMENT SUPPORT, TYPE 1

SECTIONS AND DETAIL 40-D-60001

Re le as

100A

100A

15A

25A

D1A

EG

60KW, 0.8 PF, 1800RPM

480V, 3 PHASE, 60 CYCLE

50A

D2A

D2B

River Bypass (Outdoor)

Interior Maintenance Building (Indoor)

Exterior Maintenance Building

(Outdoor)

Exterior Maintenance Building

(Outdoor)

D1B

Bused, Safety-Socket Meter Box for Self-Contained Metering with PG&E approved test-bypass facilities and test block. 480Y/277V 3 .

Underground Service Lateral. PG&E transformer to meter.

ATS

15A

Refer to PG&E Greenbook Figure 7-2 Bussed, Safety-Socket Meter Box for Self Contained Metering (101 Amps -

200 Amps, 3 ) NEMA 3R

MSD

Backup Generator

Phase's B- C

1-1Ø-5 kVA 480 - 120/240V

20A

DK1

50A

Load Bank

SPD

PG&E XFMR

Pole Mounted

1-3Ø PGE Primary - 480Y/277V

Phase's B- C

1-1Ø-5 kVA 480 - 120/240V

DK3

Phase's B- C

1-1Ø-5 kVA 480 - 120/240V

DK2

20A

L1B

25A

K1B

1-3Ø-15 KVA

480 - 208Y/120V

L1A

K1A

1-3Ø-10 KVA

480 - 208Y/120V

A 3

Phase's B- C

1-1Ø-2 kVA 480 - 120/240V

DK4

15A

480/277V 3-Phase

200A MLO

480/277V 3-Phase

100A MLO

480/277V 3-Phase 100A MLO480/277V 3-Phase

60A MLO

A 2

A 2

A 2

A 2

A 2

A 2

Fish Screen (Outdoor)

14 15

50kW, 480V, 3Ø

480V,100A, 3Ø

200kA

A 3

A 2

A 2

60A

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

D Johnson, P.E.

C Wierzbanowski

L Billy

Mendlin, Eric T P.E.

Kelly, John T P.E.

Electrical Engineer

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

4- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 2-

LA

S T

S A V

ED

B Y

EM

EN

D

LI

N

C

EN

TR

A L

V A

LL

EY

P

R O

JE

C T

S A N

J O

A Q

U

IN

R

IV

ER

R

ES

TO

R A

TI

O N

P R O

G R A M

S A C K D

A M

B

YP

A S S

MAIN

SINGLE LINE

DIAGRAM

DENVER, CO

214-D-60404

2024-02-26

NOTES

1. Refer to panel schedules for circuit breakers.

2. Refer to cable/conduit schedule for cable and conduit designations.

REFERENCE DRAWINGS

LEGEND, INDEX, POWER CABLE & CONDUIT

SCHEDULE 214-D-60394

DK1 AND DK4 PANEL SCHEDULES AND LAYOUT 214-D-60402

D1A, D1B, D2A, D2B PANEL SCHEDULES 214-D-60409

L1A, L2B, DK3 PANEL SCHEDULES 214-D-60410

EXPLANATION

DEVICE LOCATION DESCRIPTION

ATS

Maintenance Building 3 Pole Automatic Transfer Switch

D1A Maintenance Building Main 480V Panelboard

D1B Headworks Concrete Pad 480V Panelboard

D2A Maintenance Building Main Backup Power 480V Panelboard

D2B River Bypass Concrete Pad 480V Panelboard

DK1 River Bypass Concrete Pad

5KVA Transformer Load Center (480-240/120V)

DK2 Fish Screen Concrete Pad

5KVA Transformer Load Center (480-240/120V)

DK3 Fish Screen Concrete Pad

5KVA Transformer Load Center (480-240/120V)

DK4 River Bypass Concrete Pad

2KVA Transformer Load Center (480-240/120V)

K1A Maintenance Building 10KVA Transformer

K1B Maintenance Building 15KVA Transformer

L1A Maintenance Building 208V Panelboard

L1B Maintenance Building 208V Panelboard

MSD

Maintenance Building

New Service Rated Fused Disconnect Switch, NEMA 3R. 200 Amp, 600V Switch with 125 Amp Fuse, 480Y/277, 3 .

SPD

Maintenance Building Surge Protective Device

Re le as

D1A

EG60KVA, 0.8 PF, 1800RPM

480V, 3 PHASE, 60 CYCLE

D2A

D2BD1B

METER

BOX

N

ATS 3P

L1A

G

MSD

Generator

N G N G

N G

N

G

N G N G

N G

G

K1A

G

MOTOR

DISC.

(TYPICAL)

TO BURIED

GROUND

ELECTRODE

ANTENNAE

COAX CABLE

#1/0

#1/0

#6

#6

#6

GROUND RODS

#6

#6

#6

N #8

#12

#12

#12

#12

#12

BUILDING

STEEL

#X

#8 #10

#10

#8

#6

L1B N G

G

K1B

#12

BUILDING

STEEL

#10

#8 #10

#10

#8

#6

#12

#12

# 12

#12

#10

#12 #12

#10

N G

G

DK1

GROUND

PLATE

#10

#8 #10

#10

#8

#10

#6

#12

#10

#4/0 #10

#10 #10

SPD

200kA G

PER

MANUF.

N G

G

DK2

GROUND

PLATE

#10

#8 #10

#10

#8

#10

N G

G

DK3

GROUND

PLATE

#10

#8 #10

#10

#8

#10

N G

G

DK4

GROUND

PLATE

#10

#8 #10

#10

#8

#10

#12

#10

TO PG&E

XFMR

#10

N

Load Bank 50kW, 480V, 3Ø

N

TO BURIED

GROUND

ELECTRODE

#4/0

TO BURIED

GROUND

ELECTRODE

#4/0

TO BURIED

GROUND

ELECTRODE

#4/0 TO BURIED

GROUND

ELECTRODE

#4/0

TO BURIED

GROUND

ELECTRODE

#4/0

TO BURIED

GROUND

ELECTRODE

#4/0

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

D Johnson, P.E.

C Wierzbanowski

L Billy

Mendlin, Eric T P.E.

Kelly, John T P.E.

Electrical Engineer

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

4- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 2-

LA

S T

S A V

ED

B Y

EM

EN

D

LI

N

C

EN

TR

A L

V A

LL

EY

P

R O

JE

C T

S A N

J O

A Q

U

IN

R

IV

ER

R

ES

TO

R A

TI

O N

P R O

G R A M

A R R O

YO

C

A N

A L

FI

S H

S C R

EE

N

EQUIPMENT

GROUNDING DIAGRAM

DENVER, CO

214-D-60405

2024-02-26

REFERENCE DRAWINGS

LEGEND, INDEX, POWER CABLE & CONDUIT

SCHEDULE 214-D-60394

GROUNDING GRID PLAN VIEW AND

UNDERGROUND LAYOUT 214-D-60406

GROUNDING GRID PLAN VIEW AND LAYOUT 214-D-60408

EXPLANATION

DEVICE LOCATION DESCRIPTION

ATS

Maintenance Building 3 Pole Automatic Transfer Switch

DK1 River Bypass Concrete Pad

5KVA Transformer Load Center (480/120V)

DK2 Fish Screen Concrete Pad

5KVA Transformer Load Center (480/120V)

DK3 Fish Screen Concrete Pad

5KVA Transformer Load Center (480/120V)

DK4 River Bypass Concrete Pad

2KVA Transformer Load Center (480/120V)

SPD

Maintenance Building 200 kA Surge Protective Device

Re le as

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

D Johnson, P.E.

C Wierzbanowski

L Billy

Mendlin, Eric T P.E.

Kelly, John T P.E.

Electrical Engineer

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

4- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 2-

LA

S T

S A V

ED

B Y

EM

EN

D

LI

N

C

EN

TR

A L

V A

LL

EY

P

R O

JE

C T

S A N

J O

A Q

U

IN

R

IV

ER

R

ES

TO

R A

TI

O N

P R O

G R A M

A R R O

YO

C

A N

A L

FI

S H

S C R

EE

N

D1A, D1B, D2A, D2B

PANEL SCHEDULES

DENVER, CO

214-D-60409

2024-02-26

Re le as

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

D Johnson, P.E.

C Wierzbanowski

L Billy

Mendlin, Eric T P.E.

Kelly, John T P.E.

Electrical Engineer

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

4- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 2-

LA

S T

S A V

ED

B Y

C W

IE

R Z B A N

O W

S K I

C

EN

TR

A L

V A

LL

EY

P

R O

JE

C T

S A N

J O

A Q

U

IN

R

IV

ER

R

ES

TO

R A

TI

O N

P R O

G R A M

A R R O

YO

C

A N

A L

FI

S H

S C R

EE

N

LIA, L1B, DK3

PANEL SCHEDULES

DENVER, CO

214-D-60410

2024-02-26

Re le as

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

4- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 2-

LA

S T

S A V

ED

B Y

EM

EN

D

LI

N

C

EN

TR

A L

V A

LL

EY

P

R O

JE

C T

S A N

J O

A Q

U

IN

R

IV

ER

R

ES

TO

R A

TI

O N

P R O

G R A M

A R R O

YO

C

A N

A L

FI

S H

S C R

EE

N

EQUIPMENT

CONNECTION

SCHEDULE

DENVER, CO

214-D-60411

2024-02-26

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

D Johnson, P.E.

C Wierzbanowski

J Kelly, P.E.

Mendlin, Eric T P.E.

Kelly, John T P.E.

Electrical Engineer

MECHANICAL & EQUIPMENT ELECTRICAL CONNECTION SCHEDULE

EQUIP TAG

NO. #

Equipment Description Voltage (V) Phase Equip KVA Motor Size (HP) FLA Disconnect

Disconnect Fuse Size (A) Starter Notes

1 Air Burst Compressor 480 3 11.7 10 14 30A 25 NEMA 1 Refer to specification 22 15 50 for air burst compressor starter/controller requirements.

001-CP-104 Fish Screen Brush Cleaner System 480 3 11.7 2 x 5 15.2 30A 25 NEMA 1

Single point connection to 10 hp rated brush cleaner motors 1 & 2 control panel.

Panel provided by Manufacturer/Vendor.

Fish Screen Monorail Hoist (Receptacles) 480 3 4 3 4.8 Receptacle - - Refer to division 41 22 23 specification for receptacle type.

Fish Ladder Trash Rake

(Future) 480 3 - 10 - - - - Provide conduit stub up with pull string and end cap to trash rake future location.

Field verify location.

9 Septic Alarm Panel 120 1 1.2 - 10 Receptacle - - Hardwire

10 Headworks 4.5' Slide Gate #1 480 3 2.5 1.5 3 30A 10 by section

35 22 11 Extend liquid tight metal conduit (LFMC) to equipment from respective disconnect switch. Top of switch handle max height of 6'-7" above deck.

11 Headworks 4.5' Slide Gate #2 480 3 2.5 1.5 3 30A 10 by section

35 22 11 Extend liquid tight metal conduit (LFMC) to equipment from respective disconnect switch. Top of switch handle max height of 6'-7" above deck.

12 Headworks 10' Slide Gate #1 480 3 2.8 2 3.4 30A 10 by section

35 22 11 Extend liquid tight metal conduit (LFMC) to equipment from respective disconnect switch. Top of switch handle max height of 6'-7" above deck.

13 Headworks 10' Slide Gate #2 480 3 2.8 2 3.4 30A 10 by section

35 22 11 Extend liquid tight metal conduit (LFMC) to equipment from respective disconnect switch. Top of switch handle max height of 6'-7" above deck.

14 Headworks 10' Slide Gate #3 480 3 2.8 2 3.4 30A 10 by section

35 22 11 Extend liquid tight metal conduit (LFMC) to equipment from respective disconnect switch. Top of switch handle max height of 6'-7" above deck.

15 Headworks 10' Slide Gate #4 480 3 2.8 2 3.4 30A 10 by section

35 22 11 Extend liquid tight metal conduit (LFMC) to equipment from respective disconnect switch. Top of switch handle max height of 6'-7" above deck.

16 Headworks 10' Overshot Gate Hoist #1 480 3 4.0 3 4.8 30A 10 by section

41 22 10 Extend liquid tight metal conduit (LFMC) to equipment from respective disconnect switch. Top of switch handle max height of 6'-7" above deck.

17 Headworks 10' Overshot Gate Hoist #2 480 3 4.0 3 4.8 30A 10 by section

41 22 10 Extend liquid tight metal conduit (LFMC) to equipment from respective disconnect switch. Top of switch handle max height of 6'-7" above deck.

18 Fish Ramp 4.5' Slide Gate #1 480 3 2.5 1.5 3 30A 10 by section

35 22 11 Extend liquid tight metal conduit (LFMC) to equipment from respective disconnect switch. Top of switch handle max height of 6'-7" above deck.

19 Fish Ramp 4.5' Slide Gate #2 480 3 2.5 1.5 3 30A 10 by section

35 22 11 Extend liquid tight metal conduit (LFMC) to equipment from respective disconnect switch. Top of switch handle max height of 6'-7" above deck.

20 Fish Ramp 4.5' Slide Gate #3 480 3 2.5 1.5 3 30A 10 by section

35 22 11 Extend liquid tight metal conduit (LFMC) to equipment from respective disconnect switch. Top of switch handle max height of 6'-7" above deck.

21 Fish Ramp 4.5' Slide Gate #4 480 3 2.5 1.5 3 30A 10 by section

35 22 11 Extend liquid tight metal conduit (LFMC) to equipment from respective disconnect switch. Top of switch handle max height of 6'-7" above deck.

Heat Pump Outdoor

Unit (HP-1) 208 1 1.872 - 9 MCA 30A 20 by section 23 81 26

Extend liquid tight metal conduit (LFMC) to equipment from respective disconnect switch.

Heat Pump Outdoor

Unit (HP-2) 208 1 1.872 - 9 MCA 30A 20 by section 23 81 26

Extend liquid tight metal conduit (LFMC) to equipment from respective disconnect switch.

Bathroom Exhaust Fan

(EF-1) 120 1 0.055 - 0.5 Toggle - Fractional Switch with room lights

26 Booster Pump (BPS-1) 120 1 - 0.5 - Toggle - Fractional

27 Fish Screen Rectifier & Junction Box 120 1 3 - 25 - - - Make hard connection to rectifier

28 Headworks Rectifier & Junction Box 120 1 3 - 25 - - - Make hard connection to rectifier

29 001-CP-001 120 1 0.6 - - - -

30 001-CP-002 120 1 0.6 - - - - -

31 001-CP-101 120 1 0.6 - - - - -

32 001-CP-102 120 1 0.135 - - - - -

33 001-CP-103 120 1 0.135 - - - - -

34 001-CP-301 120 1 0.42 - - - - -

35 001-CP-302 120 1 0.42 - - - - -

36 FACP 120 1 - - 2.5 - - -

Re le as

Reference electrode lead (typ.)

Access port (typ.)

Anode lead (typ.)

NOT TO SCALE, SOME COMPONENTS NOT SHOWN FOR CLARITY

2" Cable conduit Carrying 9 anode cables & 1-2 reference electrode cables each

4" Cable conduit carrying reference electrode cable (typ.)

B NOT TO SCALE

1 NOT TO SCALE

2 NOT TO SCALE

0-6" from Centerline

3 NOT TO SCALE

A NOT TO SCALE, SOME COMPONENTS NOT SHOWN FOR CLARITY

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

4- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 2-

LA

S T

S A V

ED

B Y

M

JE

R M

YN

C

EN

TR

A L

V A

LL

EY

P

R O

JE

C T

S A N

J O

A Q

U

IN

R

IV

ER

R

ES

TO

R A

TI

O N

P R O

G R A M

A R R O

YO

C

A N

A L

FI

S H

S C R

EE

N

FI

S H

S C R

EE

N

FISH SCREEN CATHODIC

PROTECTION

CATHODIC PROTECTION

DENVER, CO

214-D-60415

2024-02-26

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL

M. Jermyn

M. Jermyn

G. Weber

Little, Daryl A

Tordonato, David S P.E.

Materials Engineer

R el ea se d

NOT TO SCALE

NOT TO SCALE NOT TO SCALE

ADMIN APPROVAL - Materials Engineer

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

0S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

4- D

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 2-

LA

S T

S A V

ED

B Y

M

JE

R M

YN

C

EN

TR

A L

V A

LL

EY

P

R O

JE

C T

S A N

J O

A Q

U

IN

R

IV

ER

R

ES

TO

R A

TI

O N

P R O

G R A M

A R R O

YO

C

A N

A L

FI

S H

S C R

EE

N

FI

S H

S C R

EE

N

FISH SCREEN CATHODIC

PROTECTION

EXOTHERMIC WELD AND

JUNCTION BOX DETAILS

DENVER, CO 2024-02-26

Re le as

5f t

This valve has been removed & replaced with pipe.

In 1991, we removed the pipe over canal

This was installed in 1991 and it is 5ft below the canal

This valve has been removed & replaced with pipe

This is the date for the creation of this Transmission Plat.

Place concrete level, slightly above bottom of strip.

1-Inch strip to produce a straight joint where wall surfaces are exposed to view.

4" (Approx.)

Horizontal construction joint

Tie rods

Horizontal construction joint

Tie rods

First placement concrete

Tie rod not over 6" above joint

Lap over hardened concrete not more than 1-inch, see Note 1

NOT TO SCALE

Wall

First placement concrete

NOT TO SCALE

Second placement concrete not shown.

AL

W

AY

S

TH

IN

K

SA

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

S

TA

N D

A R D

D R A W

IN

G

S

S

TA

N D

A R D

A N

D T

YP

IC

A L

D

ES

IG

N

S

C O

N C R

ET

E S

TR

U C

TU

R

ES

BUILDINGS AND OTHER

STRUCTURES

METHOD OF BUILDING

FORMS FOR SUCCESSIVE

LIFTS,DETAIL

DENVER, CO

40-D-5246

1985-05-27

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER -

C.J. MELSON

Dethlefsen, Scott R

Chambers, Christopher G

CHIEF, STRUCT. AND ARCH. BRANCH

1. A 1-inch overlap produces a far tighter contact than a much larger overlap, and results in prevention of form spread with consequent offset at the joint.

2. For General Notes for Concrete Outline and Reinforcement, see 40-D-60003.

NOTES

R

EV

N O

R

EV

N O

-0 5-

D

K .S

.K

R

ED

R A W

N A

N D

D

EL

ET

ED

V -G

R O

O V E.

-0 8-

D

J.

W

R

ED

R A W

N I

N A

U

TO

C A D

R

EV

N O

-0 4-

D

U

PD

A

TE

D D

R A W

IN

G

T

EX

T S

TY

LE

B O

R D

ER

A

N D

TI

TL

E B

LO

C K T

O C

U R R

EN

T D

R A W

IN

G

R

EC

O R D

S S

YS

TE

M

R

EM

O V

ED

S U

B M

IT

TE

D S

IG

N A

TU

R E.

IN

O

R R

EV

IS

IO

N

S

I.G. TAYLOR

G.A. ERICKSON

Re le as

Joint sealing compound

W id th W id th

Dowel bar, 1"Ø x 24" @ 12"

W id th

Reinforcement (Typ.)

NOT TO SCALE

Construction joint, see Note 6 (horizontal or vertical)

Reinforcement continuous through the joint

Reinforcement ends at joint

Joint sealing compound

Reinforcement ends at joint Expansion joint with compressible joint filler material (horizontal or vertical)

NOT TO SCALE

W id th

Reinforcement ends at joint

W id th

NOT TO SCALE

Locally depress reinforcement to provide 1" clr. cover below bottom of slot.

Control joint, 1/8" to 1/4" saw cut, see Note 3

Reinforcement (Typ.)

Reinforcement (Typ.)

Reinforcement (Typ.) Reinforcement (Typ.)

Joint sealing compound

NOT TO SCALE

W id th

Reinforcement ends at joint

Contraction joint.

Coat first placement with sealing compound to break bond.

(Horizontal or vertical)

Reinforcement (Typ.)

12"

Dowel cap (end filled with compressible material)

2" Cl. (Typ.)

2" Cl. (Typ.)

2" Cl. (Typ.)

12"

Dowel cap (end filled with compressible material)

2" Cl. (Typ.)

Dowel bar, 1"Ø x 24" @ 12"

See Note 5 (Horizontal or vertical)

For partial Cr.J, see Note 7

Expansion joint with compressible joint filler material (horizontal or vertical)

For partial Cr.J, see Note 7

Reinforcement continuous through the joint

AL

W

AY

S

TH

IN

K

SA

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

S

TA

N D

A R D

D R A W

IN

G

S

S

TA

N D

A R D

A N

D T

YP

IC

A L

D

ES

IG

N

S

C O

N C R

ET

E S

TR

U C

TU

R

ES

BUILDINGS AND OTHER

STRUCTURES

JOINTS IN CONCRETE

STRUCTURES

DENVER, CO

40-D-5247

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER -

H.H.B.

C.A.R.

N.A.A. - H.B.

ACT. CHIEF ENGINEER

NOTES

R

EV

N O

-0 8-

D

J.

W

R

ED

R A W

N I

N A

U

TO

C A D

R

EV

N O

-0 2-

D

H .O

.B

D

EL

ET

ED

C O

R K

A N

D R

EF

ER

EN

C E

TO

S

EA

LS

1. Construction joint keys and waterstops required if shown on construction drawings.

2. For General Notes for Concrete Outline and Reinforcement, see 40-D-60003.

3. Minimum depth of saw cuts shall be 1/4 of the depth of concrete unless noted otherwise on construction drawing. Saw cut joints shall be completed within 24 hours following concrete placement.

4. For joint type definitions, see construction documents (i.e., see Specifications Section 03 30 00 - "Cast-in-Place Concrete").

5. Coat surface of concrete first placed, with curing compound that prevents bond, before placing concrete on other side of joint.

6. Clean, roughen, and surface dry surfaces of CJ to be covered with fresh concrete. Do not use a mortar layer on CJ.

7. If noted on construction drawings, at partial contraction joints, discontinue every other reinforcement bar perpendicular to the joint (i.e., 1/2 of perpendicular reinforcement shall cross the joint).

FORMERLY 103-D-219

R

EV

N O

-0 4-

D

U

PD

A

TE

D D

R A W

IN

G

T

EX

T S

TY

LE

B O

R D

ER

A

N D

TI

TL

E B

LO

C K T

O C

U R R

EN

T D

R A W

IN

G

R

EC

O R D

S S

YS

TE

M

A D

D

ED

J O

IN

T

TY

PE

S

R

EM

O V

ED

S U

B M

IT

TE

D S

IG

N

A

TU

R E.

K.B. KEENER

W.E. BLOMGREN

1952-12-04

Re le

2" clr.

Fo un da tio n an ch or s (B

C as e

II

C om bi na tio n an ch or s

(C

C as e

II

I

Dowels may be omitted as shown

Foundation reinforcement not shown

Dowels may be used as shown

Existing slab

Equipment base

2" clr.

3" Min.

Cover

3" M in

C ov er

(W)

(L

S ee

N ot e

See Note 8 Reinforcement (Case II as shown)

#4@10" Max.

2 1/2" Min. Edge distance

1/ 2"

M in

G ro ut

(H

4@

6" M ax

Equipment anchor bolts (A)

Equipment anchor bolts (A)

Hook if required, see Note 1

2 1/2" Min. Edge distance

1/ 2"

M in

G ro ut

(H

#4@10" Max.

Combination foundation anchors/equipment anchor bolts (C)

Equipment base

See Note 9Foundation anchors (B)

Existing slab

#4@10" Max.

1/ 2"

M in

G ro ut

(H

Underlying concrete

See Note 9

2 1/2" Min. Edge distance

Equipment base

#4@10" Max.

2" c lr

2" c lr

2" c lr

2" c lr

2" c lr

3" = 1'-0" A 3" = 1'-0"

A 3" = 1'-0" A 3" = 1'-0"

Hook if required, see Note 1

Hex nut

Std. washer

Std. washer

Diameter Ø

Th re ad

Le ng th

3" = 1'-0"

See Note 7

1. For general notes, see 40-D-60003 and 40-D-60004.

2. Foundation sizes (L, W, H) may be shown elsewhere or establish actual dimensions to accommodate equipment furnished.

3. Locate equipment anchor bolts (A) and combination foundation anchors/equipment anchor bolts (C) from equipment and set them by template.

4. If equipment anchor bolts (A) are too long for foundation height

(H) or if (H) is less than 8 inches, use combination foundation anchors/equipment anchor bolts (C); see Case III.

5. Roughen existing concrete under all foundations.

6. For foundations of larger equipment see construction drawings.

7. Case I foundations can be used if the reinforcement is designed and positioned before the underlying concrete is placed.

The final loads, location, and dimensions (L), (W), and (H) must be known for design. Design the reinforcement size, spacing, and embedment lengths in accordance with the ACI Standards as noted on 40-D-60003.

8. Size and space the foundation anchors for Case II and Case III foundations so that all loads are transferred from the foundation to the floor.

9. Drill holes for expansion-type anchors and epoxy-type anchors to the diameter and depth recommended by the manufacturer.

NOTES

-0 6-

D

R

EV

IS

ED

A N

D U

PD

A

TE

D T

O A

U

TO

C A D

D R A W

IN

G

-0 4-

D

R

EV

IS

ED

A N

D R

ED

R A W

N T

O S

H O

W S

TA

TE

-O

F-

TH

E- A R T

A N

C H

O R A G

E A N

D G

EN

ER

A L

U

PD

A

TI

N G

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

S

TA

N D

A R D

D R A W

IN

G

S

S

TA

N D

A R D

A N

D T

YP

IC

A L

D

ES

IG

N

S

C O

N C R

ET

E S

TR

U C

TU

R

ES

SMALL EQUIPMENT

FOUNDATIONS

OUTLINE AND

REINFORCEMENT PLAN

AND SECTIONS

DENVER, CO

40-D-5599

1983-04-27

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER -

JAMES R. VERNON

KATHRYN S. KUGE

CHIEF, STRUCT. AND ARCH. BRANCH

-0 4-

D

M

IN

O R R

EV

IS

IO

N

S

-1 2-

D

U

PD

A

TE

D D

R A W

IN

G

T

EX

T S

TY

LE

B O

R D

ER

A

N D

TI

TL

E B

LO

C K T

O C

U R R

EN

T D

R A W

IN

G

R

EC

O R D

S S

YS

TE

M

R

EM

O V

ED

S U

B M

IT

TE

D S

IG

N A

TU

R E.

W - Denotes width L - Denotes length H - Denotes height

ABBREVIATIONS

JERRY R. DEXTER

W.R. ANDERSON

Re le

Eq ua l s pa ce s

/4

7/ 8"

1/

1/ 4"

M in.

1/ 4"

M in.

R1/8" Fillet

7/

8"

1/

Eq ua l s pa ce s

/4

9"

1/

8"

Eq ua l s pa ce s

/8

3/ 4"

1/

3/ 4"

1/

Eq ua l s pa ce s

/8

S pa ce s

/1 6"

1/4" Min. I.D.

sp ac es

/1 6"

1/ 8"

1/ 8"

1/

8"

7/

8" M ax

1/2" Min.

7/ 8"

M in.

1/4" Min.

1/4" Min.

1/

1/ 8"

3/16" Min.

1/ 4"

M in.

1/ 4"

M in.

1/

2" M ax

3/8" Min.

1/

1/ 8"

1/ 8"

1/ 8"

3/16" Min.

1/4" Min.

1/4" Min.

1"

1/

1"

1/

6"

1/

8"

1/ 8"

1/ 8"

3/16" Min.

3/16" Min.

1/

1/ 8"

3/ 4"

Max . O

.D

1/8" Min.

3/

" M in.

(T yp

3/8" Min.

R1/8" Fillet

7/ 8"

M in.

R1/8" Fillet

NOT TO SCALE

NOT TO SCALE

NOT TO SCALE

I.D

O.D

I.D

O.D

1. Tips of fins may be rounded provided they meet the minimum dimensions shown.

2. Movement Joints Type - to accommodate for significant movement due to drying, shrinkage, temperature changes, settlement, creep, or live load deflection.

3. Ribbed Center Bulb Type - sealing type waterstop, to accommodate lateral, transverse, and shear movement.

NOTES

-0 4-

D

U

PD

A

TE

D D

R A W

IN

G

T

EX

T S

TY

LE

B O

R D

ER

A

N D

TI

TL

E B

LO

C K T

O C

U R R

EN

T D

R A W

IN

G

R

EC

O R D

S S

YS

TE

M

R

EM

O V

ED

S U

B M

IT

TE

D S

IG

N A

TU

O

R R

EV

IS

IO

N

S

-1 2-

D

R

ED

R A W

N I

N A

U

TO

C A D

9-

-9

D R

ED

R A W

N T

O I

N C

LU

D E

TY

PE

8-

-9

D A S B

U

IL

T B Y

3, L

TR

7-

-9

1.

-9

-8

D R

EV

IS

ED

F

IN

S O

N

TY

PE

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER -

W. C. STEVENSON

M. WORTHY / W. ALBECHT / N. L. B.

W. C. STEVENSON

ACT. CHIEF, DIVISION OF DESIGN

AL

W

AY

S

TH

IN

K

SA

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

S

TA

N D

A R D

D R A W

IN

G

S

S

TA

N D

A R D

A N

D T

YP

IC

A L

D

ES

IG

N

S

PV

C W

A

TE

R S

TO

PS

12-INCH TYPE, 9-INCH

TYPE, AND 6-INCH TYPE

CROSS-SECTIONS

DENVER, CO

40-D-6463

1979-06-12

I.D. denotes inside diameter O.D. denotes outside diameter

ABBREVIATIONS

M.J. BERNSTEIN

H.W. ANDERSON

Re le

Amendment No. 0004

7"

5" 5"

Drill for 34"-coupling with chase nipple.

Weld all around

4" Nipple to suit with reamed inside edges Conduit fitting

For in and out installation

Top of concrete

Coupling, or elbow hub, as required

DETAIL 1

2" 21

2"11 2" 11

2"

8"

11 2"

6" M in . 51 2"

CL. Std. pipe and 16"Ø vent hole

Face of concrete

8" Pl.

CL. 13

16"Ø Holes in plate for

8"Ø expansion anchors

SECTION A-A

21 2" 11 2"

Gate or walkway side

2" Std. pipe

2" Std. pipe

CL. Guardrail

SECTION B-B

G

3"

8"Ø Expansion eye bolt

See Note 8

Typical return or typical end post

2" Std. pipe

To Pipe To Wall

TYPICAL CHAIN DETAILS

AS REQUIRED

A A

8'-0" Max. between guardrail posts 8'-0" Max. between guardrail posts

G

3' -5

Face of wall or CL. of adjacent pipe guardrail

1'-0"

1' -2

1'

-2

90° L.R. Std. butt welding elbow

2" Std. pipe

Top of concrete

TYPICAL RETURN TYPICAL CENTER POST TYPICAL END

POST

TOP MOUNTED PIPE GUARDRAIL

G

4"

2" Std. pipe

Min.

6"

TYPICAL LIGHT POST

1' -2

B B

C oo rd in at e w ith e le ct ri ca l i ns ta lla tio ns21

2" Std. pipe

2" Std. pipe

1' -2

1'

-1

1'-0"

G

90° L.R. Std. butt welding elbow

Provide post 1'-0" from all horizontal bends

2" Std. pipe

TYPICAL GUARDRAIL

HORIZONTAL BEND

4' -0

M ax

To n ex t po st

2" Std. pipe

6" Min.

Top of concrete Top of concrete See Detail 1

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

LAR M TA IOCE N

C A D

S

YS

TE

M

A ut oC A D

3.

0s C A D

F

IL

EN

A M

E

-D -6

2-

R D

-1 .D

W G

LA

S T

S A V

ED

D A

TE

-0 1-

LA

S T

S A V

ED

B Y

R R O

D R

IG

U

EZ

S

TA

N D

A R D

D R A W

IN

G

S

S

TA

N D

A R D

A N

D T

YP

IC

A L

D

ES

IG

N

S

M

IS

C

EL

LA

N

EO

U

S M

ET

A

LW

O R K

PIPE GUARDRAILS

TOP MOUNTED PIPE

GUARDRAILS

ELEVATION, SECTIONS,

AND DETAILS

DENVER, CO 1993-01-07

PEER REVIEWER -CHIEF, CIVIL ENG. DIVISION

NOTES

1. Not all information shown on this drawing may be needed for every job. Use information on this drawing as required.

2. Galvanize all ferrous metalwork after fabrication. Provide vent holes as required in bottom of pipe.

3. All material is steel unless otherwise noted.

4. Splice guardrail as required with splice locks. Provide splice lock suitable for expansion joint at 50 foot centers maximum and at expansion joints in concrete.

5. Contractor determines guardrail lengths based on dimensions of structures. See structure drawings for location and extent of guardrails.

6. Grind all welds smooth.

7. Details, welds, and other connections shown are typical for all similar conditions.

8. 1

4"Ø Galvanized chain with maximum sag of 2-inches. Provide "S" hook and heavy duty swivel snap at one end. Weld single chain link to opposite end post or return.

T. C. GRABER

JOHN D. SMART

-0 1-

D

U

PD

A

TE

D D

R A W

IN

G

T

EX

T S

TY

LE

B O

R D

ER

A

N D

TI

TL

E B

LO

C K T

O C

U R R

EN

T D

R A W

IN

G

R

EC

O R D

S S

YS

TE

M

N

U M

B

ER

ED

N

O

TE

S A

N D

D

EL

ET

ED

S U

B M

IT

TE

D S

IG

N

A

TU

O

R R

EV

IS

IO

N

S

9-

-0

D A D

D

ED

A N

C H

O R T

O S

EC

TI

O N

A -A

C

H A N

G

ED

G U

A R D

R A

IL

H

EI

G H

T

FR

O M

6" T

O

5"

Re le

"A" + 6"

SECTION C-C

1' -9

Safety gate not shown, see Note 7

4" Std. pipe

90° L.R. standard butt welding elbow

G

3' -6

LADDER - TYPE 3A

Eq ua l r un g sp ac in g

0" M ax

0"

M in

8' -0

M ax be tw ee n su pp or ts

3" 8'

-0

M ax be tw ee n su pp or ts 2" T yp

4" T yp

A A

2'-4"

Top rung flush with landing

C

Top landing

4" Std. pipe

1' -0

M ax

Safety gate, see Specifications

6"

1'-8"

45° L.R. standard butt welding elbow

1'-2" 1'-2"

10" 10"

CL. Ladder

0" M ax

2" T yp

4" T yp

B B

3'-0"

6"

1'-8"

1'-6" 1'-6"

10" 10"

CL. Ladder, safety rail, and extension

(For distances not exceeding 24'-0" between landings)

3' -0

Safety rail, see Specifications

C

Safety gate, see Specifications

Top rung flush with landing 45° L.R. standard butt welding elbow

Top landing

Permanent dismount extension as recommended by safety rail manufacturer

4" Std. pipe

LADDER - TYPE 3B

(For distances exceeding 24'-0" between landings)

3"

6"…