140R2022R0003_Amendment_0006_0006.pdf
PDF 11 MB Posted
- Attached to
- New Melones Generator Rewind Federal contract opportunity
- Solicitation number
- 140R2022R0003
About this file
This amendment to solicitation 140R2022R0003 from the Department of the Interior Bureau of Reclamation is for generator rewind services at the New Melones Powerplant. Offerors are to provide all labor, equipment, and materials to remove, transport, rewind, test, and reinstall two generators. The deadline for responses is April 15, 2022, with award anticipated by May 1 and work to be completed within six months of the award date. Small businesses, HUBZone certified, service-disabled veteran-owned, and women-owned small businesses are encouraged to respond.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Copy_of_MEP-Rewind-Ops_Data-U1_U2-Historian-06162022_0008.xlsx | XLSX spreadsheet | |
| 140R2022R0003_Amendment_0008_0008.pdf | ||
| Sol_140R2022R0003_Amd_0008.pdf | ||
| 140R2022R0003_Amendment_0007_0007.pdf | ||
| Sol_140R2022R0003_Amd_0007.pdf | ||
| Sol_140R2022R0003_Amd_0006.pdf | ||
| Sol_140R2022R0003_Amd_0005.pdf | ||
| 140R2022R0003_Amendment_0005_0005.pdf | ||
| 140R2022R0003_Amendment_0004_0004.pdf | ||
| Sol_140R2022R0003_Amd_0004.pdf | ||
| 140R2022R0003_Amendment_0003_0003.pdf | ||
| Sol_140R2022R0003_Amd_0003.pdf | ||
| 140R2022R0003_Amendment_0002_0002.pdf | ||
| Sol_140R2022R0003_Amd_0002.pdf | ||
| Amendment_0001_0001.pdf | ||
| Sol_140R2022R0003_Amd_0001.pdf | ||
| Solicitation_140R2022R0003.pdf | ||
| Sol_140R2022R0003.pdf |
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
(x)
140R2022R0003 x x copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted ; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE
RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR
OFFER. If by virtue of this amendment you desire to change an offer already submitted , such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
x
Sacramento CA 95825-1898 2800 Cottage Way, Room E-1815
R20
Division of Acquisition Services Regional Office Mid-Pacific Region Bureau of Reclamation
06/03/20220006
13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS. IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
12. ACCOUNTING AND APPROPRIATION DATA (If required) is not extended.is extended, Items 8 and 15, and returning
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended , by one of the following methods: (a) By completing
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
FACILITY CODE CODE
10B. DATED (SEE ITEM 13)
10A. MODIFICATION OF CONTRACT/ORDER NO.
9B. DATED (SEE ITEM 11)
9A. AMENDMENT OF SOLICITATION NO.
CODE
8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code)
7. ADMINISTERED BY (If other than Item 6)CODE 6. ISSUED BY
PAGE OF PAGES
4. REQUISITION/PURCHASE REQ. NO.3. EFFECTIVE DATE2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO. (If applicable)
1. CONTRACT ID CODE
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
04/18/2022
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority) appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
E. IMPORTANT: Contractor is not is required to sign this document and return __________________ copies to the issuing office.
ORDER NO. IN ITEM 10A.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
Legacy Doc #: BOR
A. TITLE: New Melones Powerplant Generator Rewind
B. PURPOSE: The purpose of this amendment is to incorporate 7 additional attachments in
Section J, replace Section B (Supplies or Services and Prices/Costs), replace Section C
(Table of Contents), and replace Specifications 01 11 00 and 01 33 00.
C. DESCRIPTION: This amendment hereby incorporates the following:
Insert Section J Att. No. 15, Amendment 0006 - Questions and Answers, Set 3
Continued ...
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)15A. NAME AND TITLE OF SIGNER (Type or print)
15C. DATE SIGNED 16B. UNITED STATES OF AMERICA 15B. CONTRACTOR/OFFEROR 16C. DATE SIGNED
(Signature of person authorized to sign) (Signature of Contracting Officer)
Erik M. Danger
STANDARD FORM 30 (REV. 11/2016)
Prescribed by GSA FAR (48 CFR) 53.243
Previous edition unusable
Except as provided herein, all terms and conditions of the document referenced in Item 9 A or 10A, as heretofore changed, remains unchanged and in full force and effect .
ITEM NO. SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT
NAME OF OFFEROR OR CONTRACTOR
2 2
CONTINUATION SHEET
REFERENCE NO. OF DOCUMENT BEING CONTINUED PAGE OF
(A) (B) (C) (D) (E) (F)
140R2022R0003/0006
Insert Section J Att. No. 16, Amendment 0006 -
Drawing 167C7953 Generator Lifting Device
Insert Section J Att. No. 17, Amendment 0006 -
Drawing 135D5310 Generator Lifting Arrangement
Insert Section J Att. No. 18, Amendment 0006 -
Drawing 136D6105 Gen Shaft Lifting Device
Insert Section J Att. No. 19, Amendment 0006 -
Drawing 136D6019_Piping_B
Insert Section J Att. No. 20, Amendment 0006 -
Machine Characteristics
Insert Section J Att. No. 21, Amendment 0006 -
Machine Curves
Remove Continuation of Section B, Supplies or
Services and Prices/Costs, in Section B and
Replace with Continuation of Section B, Supplies or Services and Prices/Costs, Amendment 0006 in
Section B
Remove Description/Specifications Table of
Contents in Section C and Replace with
Description/Specifications Table of Contents, Amendment 0006 in Section C
Remove 01 11 00 - Summary of Work in Section C and Replace with 01 11 00 - Summary of Work, Amendment 0006 in Section C
Remove 01 33 00 - Submittals in Section C and
Replace with 01 33 00 - Submittals Amendment 0006 in Section C
NSN 7540-01-152-8067 OPTIONAL FORM 336 (4-86)
Sponsored by GSA
FAR (48 CFR) 53.110
New Melones Powerplant Generator Rewinds
Pre-Proposal Questions and Answers
Question Set 3
1. Question: There is no date for phase resistance in the provided documents. What is the phase response?
Reclamation Response: See responses to questions provided in amendment 5.
2. Question: Some performance test data would be helpful. Please provide Performance test data from each unit.
Reclamation response: Minimal data is available. Capability curves and exciter field test data are included.
3. Question: The Bus Rings ID is provided. There appears not to be enough data for an advance supply of blocking and hardware to mount bus rings. Please supply the Blocking details for the rings.
Reclamation Response: Blocking details are not available.
4. Question: Spec. Section 48 13 03-2, 1.04, A, 3 identifies minimum qualifications for UT Level III.
This is not common, as Level II performs the UT. Level III’s typically do not perform the actual UT. Can the minimum qualification be changed to Level II?
Reclamation Response: No.
5. Question: Spec. Section 09 96 20, RSN 09 95 29-3 specifies 4 by 6” color chips. The Contractor currently went through this requirement with another customer and paint chips are not as common as they once were. They are difficult to come by. Can the word “chip” be removed?
Reclamation Response: Yes, color selection swatches are acceptable.
6. Question: Section J attachment 4 includes a subcontracting plan. Please confirm there is a minimum Small Business % utilization goal in this solicitation.
Reclamation Response: The Department of Interior goals are as follows
New Melones Powerplant Generator Rewinds Pre-Proposal Questions and Answers Question Set 3
pg. 2
SB (Includes HUBZone SB, SDB, WOSB, VOSB, SDVOSB, ANCs, and Indian tribes)
50%
VOSB 3%
SDVOSB 3%
HUBZone SB 3%
SDB (Includes ANCs and Indian tribes) 5%
WOSB 5%
7. Question: Tabulation No. 1 applies to Commercial or manufacture’s product with a standard applied coating system.
Are rigid grooved pipe couplings included in this tabulation as a commercial product?
The specification requires to coat all associated fasteners to include nuts, bolts, washers, and exposed anchors after assembly.
Standard fasteners supplied with grooved pipe couplings are zinc plated. Zinc plated surfaces cannot be coated without special surface preparation. What is the coating requirement for zinc plated fasteners for grooved couplings after installation?
Reclamation Response: Yes, grooved type pipe couplings shall be coated in accordance with the manufacturer’s product data and application sheet.
8. Question: Tabulation No. 2 requires to coat the exterior surface of cooling water piping, fittings, and appurtenances. The new cooling water piping inside the air housing must be insulated.
Does BOR require to coat the piping covered with insulation? Existing insulated piping in the air housing is not coated. Existing flanges, grooved couplings and fasteners are coated.
Reclamation Response: See section 22 10 12, Part 2.03 8.
9. Question: Tabulation No. 2 requires to coat all associated fasteners to include nuts, bolts, washer, and exposed anchors after assembly. Would hot dip galvanized flange fasteners (bolts, washers and nuts) be an acceptable substitute to coating system of Tabulation 2?
Reclamation Response: No, coat in accordance with Tab. 2.
10. Question: Tabulation No. 2 requires to coat all associated fasteners to include nuts, bolts, washers, and exposed anchors after assembly. The coating system requires blast cleaning
Pre-Proposal Questions and Answers Question Set 3
pg. 3
Method C or H for surface preparation, which is impractical after assembly on site. Would you confirm the minimum surface preparation recommended by the coating manufacture is acceptable?
Reclamation Response: Touch-up of fasteners after assembly in accordance with the manufacturer’s instructions is acceptable.
11. Question: Would you clarify the coating of the grooved type couplings? Standard groove pipe couplings come painted with zinc plated fasteners. Alternatively, they can be hot dip galvanized with stainless steel fasteners for better corrosion resistance. We noticed that some grooved pipe couplings on the existing cooling water system appear to be galvanized. The specification does not provide any detail about the finish of the coupling.
Reclamation Response: See the response to question 10.
12. Question: Paragraph 3.02 E. 3 requires to remove and dispose air cooler vent piing and associated valves within the air housing. Paragraph 3.02 E. 1 refers to drawings 136-D6019 sheets 1 and 2 that shows flanged pipe spools that are outside the air housing and the 8” supply and discharge pipes that extend down through the air housing floor to a flange. Would you confirm the limits of the removal and replacement? We currently assume that the lower pipe spool that is completely outside the air housing is excluded from the removal and replacement.
Reclamation Response: See attached highlighted drawings 136-D-6019 sheets 1 and 2 to identify the limits of removal and replacement.
13. Question: Reference to section 01 14 30, paragraph 1.03. Contractor wants to confirm the definition of the outage dates (interruption of service). Contract is assuming that the start will occur after de-watering and LOTO of the unit (performed by the Government). Contractor is assuming that the end will occur after the completion of the commissioning. Please confirm Contractor’s understanding.
Reclamation Response: No, the interruption in service begins when the Unit is taken out of service and no longer available for generation. Assume a one-day duration for the Government to unwater the unit and apply Hazardous Energy Controls. Also, assume a one-day duration for the government to remove Hazardous energy controls and water up the unit. The end of the outage is after completing commissioning.
14. Question: Can the Government please confirm the mandatory Holidays that the Contractor must consider in its site schedule?
Pre-Proposal Questions and Answers Question Set 3
pg. 4
Reclamation Response: This project does not include mandatory holidays. Work on federal holidays shall be considered as work outside of powerplant normal work hours as defined in section 01 14 12, Part 1.02 D.
15. Question: Can the Government confirm that none of the different required site reports and Government review time should be considered as waiting time during the execution of site works? Contractor proposes to add acceptance milestones (hold points, zero duration) for critical decision items so the Government can immediately confirm that the Contractor can pursue the work without adding waiting time to the critical path. In the case of an inspection, if any additional work is recommended by the Contractor and approved by the Government, a time impact analysis would then be performed to evaluate the time extension required (section 01 32 10, paragraph 1.08).
Reclamation Response: Inspection of Construction is accordance with Section E, Inspection and acceptance.
16. Question: Section 48 13 71, item 2.03 E. 2, requests before application of ground wall insulation, impregnate and encapsulate slot portions of bars with epoxy or polyester resin compound to fill and bond transposed strands forming a dense, solid, and void-free structure. We request to change this text for: “before application of ground wall insulation, impregnate and consolidate slot portions of bars with epoxy or polyester resin compound to fill and bond transposed strands forming a dense, solid, with minimal voids structure. In this way, the requirement is compatible with section 4813 71, item 2.03 F 4, since 100% void-free is not possible to guarantee. Small voids are not harmful since field stress between strands is very low.
Reclamation Response: Minimal void structure clarification is acceptable. It is understood that the term “void-free” does not represent 100% void-free guarantee.
17. Question: Section 48 13 71, item 2.04 B 1 and 3.01 E. 2 requests to provide flat filler strips of semi-conducting material. We request to change this paragraph since the surge rings segments are partially insulated from shop. Only the segment junctions are insulated at site.
Reclamation Response: See section 48 13 71, Part 2.06-B for surge rings.
18. Question: Section 48 13 71, item 2.13 B 4 requests to perform insulation Resistance and Polarization Index test at 10 KVDC and in accordance with IEE 43. We request to perform this only at site, after bar installation.
Reclamation Response: No, manufacturer’s tests shall include Insulation Resistance and Polarization Index test at 10 kVDC and in accordance with IEE43.
Pre-Proposal Questions and Answers Question Set 3
pg. 5
19. Question: Section 48 13 71, item 2.13 B 6 requests to stamp, mark, paint or clearly note tip-up test value on each bar for easy identification during installation. We request to provide a record of all tests performed at shop in the bar data sheet. These Erection Sheets will record which bar will be installed in which slot. Then traceability of the bar is ensured. Also, we would identify and pack separately only bars with tip-up higher than 0.6% for installation close to neutral end.
Reclamation Response: Tip-up value recorded on a test record and correlated to the bar number is acceptable.
20. Question: Section 48 13 63, 3.02 Installation specification text “Distribute 20 RTDs evenly around on back of core, producing temperature profile representative of core bulk heating during operation.” We understood that existing core has already 20 RTDs which we need to replace with the new 20 RTDs. We do not need to make new slots on the back of core to insert the RTDs. Kindly confirm our understanding
Reclamation Response: No, the core does not have existing RTDs. Contractor to provide mounting design and installation provisions for new RTDs.
21. Question: Will we be able to use the top of the unit we are not working on as a laydown area for parts removed from the unit under construction? If so, what is the floor loading capacity?
Reclamation Response: No.
22. Question: Is there plant internet available for contractor to use?
23. Question: Kindly provide us the list of available existing lifting tools and tackles which will be allowed to used during the execution of the work. Are these tools to be handed over to bidder after re-certification or do bidders need to perform the re-certification of these tools?
Reclamation Response: See attached drawings 136D6105, 167C7953 and specification drawing 135D5310 with lifting devices available to the Contractor. The Government intends to certify lifting devices shown on these drawings prior August of 2023.
24. Question: Section L, Past Performance – The section b) ix) requires requesting new PPQ’s and have them sent directly to USBR. It has been very difficult to get the owners of such projects to send a new form for every single proposal directly to the requester, which easily can be multiple times each year. As such it has been acceptable in past USBR and also USACE to attach previously received PPQ’s to the proposal. We would highly appreciate if the USBR could allow existing PPQ to be used rather than requesting new ones again.
Pre-Proposal Questions and Answers Question Set 3
pg. 6
Reclamation Response: Use of existing PPQs is acceptable.
25. Question: We have difficulties to provide a compliant bid in the time remaining (June 16) due to resource issues with other outgoing bids. Can you please give us an additional week for the bid preparations?
Reclamation Response: See amendment 5 with a revised proposal due date of June 23, 2022.
26. Question: What is the purpose of the video surveillance equipment required under this contract and USBR wanting to capture in this surveillance?
Reclamation Response: Section 28 23 00 Video Surveillance System will be removed from the conformed contract. See the attached revised sections B, 00 10 00, 00 11 00 and 01 33 00 with video surveillance system requirements removed with strike-through. For information only, the facility has existing cameras located at the powerplant for security purposes.
27. Question: Is the video surveillance equipment required by this contract defined as “covered telecommunications equipment or services” per FAR 42.204-24?
Reclamation Response: See the response to question 26.
28. Question: The video surveillance causes a lot of additional Administration and also Liability: We would have to inform any subcontractor, employee at site that they are taped. Also 3rd party contractors brought in by the USBR or other have to be informed by USBR. Since we and the USBR are no used to that, it could become a big liability if we miss one. We (Contractor and USBR Would) have to include language in all subcontracts and post signs. Who’s responsibility is it going to be? Can the USBR indemnify us against any liability if 3rd parties or USBR sues?
29. Question: Has the USBR checked with the local unions will accept being monitored? If not we suggest to do so in order to prevent site work interruptions due to strikes.
30. Question: Is surveillance of employees permitted per California Law. And is it permitted by USBR rules and regulations to tape their employees, as they will also be on tape during visits, inspections, etc.
31. Question: Is the rotor lifting bracket certified and load tested?
Pre-Proposal Questions and Answers Question Set 3
pg. 7
Reclamation Response: See the response to question 23.
32. Question: Section 48 13 63 1.04 A refers to removal and disposal of hazardous coatings on the exterior of the stator frame. Can we get clarification on paint locations (entire frame, outside stator walls, inside bore, top and bottom?) that needs to be removed and if blasting is required?
Reclamation Response: See amendment 5 and refer to the response from question 4 of Q&A 2.
33. Question: Section 48 13 71 3.01 C a and c asks that we use chill blocks and not use water-soaked materials. Our standard procedure does not use chill blocks and uses water soaked materials.
We have not encountered any problems brazing using this method. We would as for exceptions to this requirement. Should we put this in under exceptions or clarification or will the USBR respond to it now?
Reclamation Response: Use of chill blocks and without water-soaked material shall be in accordance with section 48 13 71 Part 3.01 C. No exception shall be granted.
34. Question: Section 48 13 44 3.02 C states to blast the weld location on the lower bracket. Would chemical stripping be acceptable?
35. Question: Section 48 13 57 3.02 C states to blast the weld locations on the rotor. Would chemical stripping be acceptable?
A
2 >.<',' LG, \.\\?"._LE)
• • Cr [) '/£t<T OT.I-\Q,G.,170 Fl_/>,(,(, ()I( EQ, i:''C,F \.\H\ON c.L/� t2. SCRcd\E
ELD /\LL /1.1'(0\jflD z c,<:. E\... • "" z· STEEL CO\JPL\tl_<:\� l'\ELD.
r
\ "" 'Nf\Et\ A">SDloL\t\G -llPP\:R CO:_ER_'!r�L:!_l>;�T�c.::':S>__-1--- - - ----:.,�--. !
2-2'CLDSE N\P?L/S
--· �'r" k« ,.,.,w,,om
J-\'CLOS'c N\?'?lE
§ 5_
1-\". l c, f lll\\Ot\ -------�---�
1====================�
.:_-c-_��������=-�=-������� :::::�:�-���:J' � ,8
,., J
.,,, G" GROOVE\J-1'(�
- 0 ,¼ ?U\E '
COllPLII-\G
F _LI ·1- --1·
C
D
E
F
G"BV-1 LOl-\G , Ii :,4 R.£L. \ ;-'- t f N?l ,RJ\HSD\.\t<:R ·•coi-;N.
2.."pl�\E
2-1' T\\R'cllOLETS ,2
\ srnc EL C.Ol'?EK,M.1',, 1-1 UN..10\-.\ c..�c � i-1" UN\Ot\ EL Cx..C \-\'G,t,.,T'c VA.LY£ (2 'rl.../1.C.E'S)
6 M! <\S" El. ---
"( 16 1
_,, l Jt I
I
1 ""o .. 1 · . -
\ i ' cl 1,sJ�f-i - G"2' · -�J�:;h,:'fi ";irr �r I :,:�•;::\''" I.-- r _�-� -- I ,, -----. 15/; /"·l.....o.. ..:-�EADERo, I -El. 522,4<o-
.I _J
_ If D\SC.f\/>,l':.Gt 'Sll?il\'
__ L_ - - -- '
--�-LS
I ..---;=,_),
· - ✓r·
;_/·.· "� rl°"LD W£.Lt)_
GO"
s'cE non: � • ~ SEE no·rE � 10_
I
EI7f
4 5 8
K,,1, 1111t
Amendment 0006 Att. No. 19 mlazanas Rectangle mlazanas Callout combo air/vac valve mlazanas Text Box 136-D-6019 mlazanas Rectangle mlazanas Rectangle mlazanas Callout mlazanas Callout angle valves x2 @ each air cooler mlazanas Polygonal Line mlazanas Callout replace cooling water piping down to 8-inch flange connection here mlazanas Rectangle mlazanas Rectangle mlazanas Rectangle mlazanas Callout location of pressure transducer connection to cooling water supply header mlazanas Rectangle mlazanas Callout vent piping *note 2 mlazanas Polygonal Line mlazanas Callout mlazanas Polygonal Line mlazanas Rectangle mlazanas Text Box vent piping *note 2 mlazanas Text Box Note 1:
Remove and replace all cooling water piping shown on this drawing, and within the air housing, down to 8-inch flange connection as indicated.
Note 2:
Replace air cooler vent piping from port connection on cooler up to and including 1/2-inch gate valve. Vent piping to be removed and replaced for all 6 air coolers in each unit mlazanas Rectangle
Amendment 0006 Att. No. 21
Central Valley Project, California Solicitation No.
Price Schedule B - 1
CONTINUATION OF
SECTION B – SUPPLIES OR SERVICES AND PRICES/COSTS
NEW MELONES POWERPLANT
GENERATOR REWINDS
CENTRAL VALLEY PROJECT, CALIFORNIA
B.1 PRICE SCHEDULES
Offers will be considered for award on the following Price Schedules, but no offer will be considered for award on only a part of the Price Schedules.
Offerors shall complete Price Schedules A, B, C, and D. Offers for less than the total of Schedules A, B, C, and D will be considered and will not be evaluated for award.
Offers will be evaluated based on the total of Price Schedules A, B, C, and D.
The Government will award Price Schedules A and B. Price Schedules C and D are Optional Price Schedules. The Government may award Price Schedule C, or Price Schedule D, or Price Schedules C and D, based on results from required inspections.
Offers are subject to the terms and conditions of this solicitation.
Quantities in the Price Schedules are estimated quantities for comparison of offers only.
Except as provided in the contract clause at FAR 52.211-18, Variation in Estimated Quantity, no claim shall be made against the Government for overruns or underruns. The contract clause at FAR 52.211-18, Variation in Estimated Quantity does not apply to lump sum items.
See the contract clause at WBR 1452.232-81, Payment for Mobilization and Preparatory Work, for CLINs A-1 and B-1.
Definitions:
CLIN – Contract Line Item Number.
Central Valley Project, California Solicitation No.
Price Schedule
B - 2
PRICE SCHEDULE A – Generator G1
CLIN Section Supplies or Services Quantity and Unit
Unit Price
Amount
A-1 WBR
1452.232
-81
Mobilization and Preparatory Work
For the lump sum of $
A-2 FAR
52.246-
Extended Warranty for Armature Winding
For the lump sum of $
A-3 01 31 30 Contract Document Management System for Generator G1 and Generator G2
For the lump sum of $
A-4 01 78 30 Final As-built Drawings For the lump sum of $
A-5 22 10 04 Removal of Equipment For the lump sum of $
A-6 22 10 12 Plant Auxiliary Piping and Appurtenances
For the lump sum of $
A-7 22 11 24 Unit Cooling Water Pumps For the lump sum of $
A-8 22 11 83 Automatic, Self-Cleaning Strainer
For the lump sum of $
A-9 22 11 85 Generator Air Coolers For the lump sum of $
A-10 26 09 12 Medium-Voltage Potential Transformers
For the lump sum of $
A-11 28 23 00 Video Surveillance System For the lump sum of $
A-12 48 13 04 Disassembly and As-Found Readings
For the lump sum of $
A-13 48 13 07 Reassembly and Alignment For the lump sum of $
A-14 48 13 08 Commissioning For the lump sum of $
A-15 48 13 09 Critical Connection Fasteners
For the lump sum of $
A-16 48 13 16 Turbine Guide Bearing For the lump sum of $
A-17 48 13 17 Generator Bearings Refurbishment
For the lump sum of $
TDooley Cross-Out
B - 3
PRICE SCHEDULE A – Generator G1
CLIN Section Supplies or Services Quantity and Unit
Unit Price
Amount
A-18 48 13 43 Rehabilitation of Generator Brake Ring
For the lump sum of $
A-19 48 13 43 Rehabilitation of Generator Brake and Jack Cylinder Assemblies
For the lump sum of $
A-20 48 13 43 Brake Dust Collection System
For the lump sum of $
A-21 48 13 44 Thrust Bracket Inspections 305 lin ft $ $
A-22 48 13 44 Thrust Bracket Coatings For the lump sum of $
A-23 48 13 57 Rotor Inspections 600 lin ft $ $
A-24 48 13 57 Rotor Coatings For the lump sum of $
A-25 48 13 62 Provide Generator Work Platform and Temporary Staircase/Ladder
For the lump sum of $
A-26 48 13 62 Remove and Dispose of Armature Winding
For the lump sum of $
A-27 48 13 63 Preparing and Testing Existing Stator Core
For the lump sum of $
A-28 48 13 71 Furnish and Factory Test New Armature Winding
For the lump sum of $
A-29 48 13 71 Install and Field Test New Armature Winding
For the lump sum of $
A-30 48 13 72 Ventilation Design Review Study
For the lump sum of $
A-31 48 13 72 Replace Generator Air Baffles
For the lump sum of $
A-32 48 13 93 Generator Neutral Grounding Equipment
For the lump sum of $
TOTAL FOR PRICE SCHEDULE A $_________________
B - 4
PRICE SCHEDULE B – Generator G2
CLIN Section Supplies or Services Quantity and Unit
Unit Price
Amount
B-1 WBR
1452.232
-81
Mobilization and Preparatory Work
For the lump sum of $
B-2 FAR
52.246-
Extended Warranty for Armature Winding
For the lump sum of $
B-3 01 78 13 Final As-built Drawings For the lump sum of $
B-4 22 10 04 Removal of Equipment For the lump sum of $
B-5 22 10 12 Plant Auxiliary Piping and Appurtenances
For the lump sum of $
B-6 22 11 24 Unit Cooling Water Pumps For the lump sum of $
B-7 22 11 83 Automatic, Self-Cleaning Strainer
For the lump sum of $
B-8 22 11 85 Generator Air Coolers For the lump sum of $
B-9 26 09 12 Medium-Voltage Potential Transformers
For the lump sum of $
B-10 28 23 00 Video Surveillance System For the lump sum of $
B-11 48 13 04 Disassembly and As-Found Readings
For the lump sum of $
B-12 48 13 07 Reassembly and Alignment For the lump sum of $
B-13 48 13 08 Commissioning For the lump sum of $
B-14 48 13 09 Critical Connection Fasteners
For the lump sum of $
B-15 48 13 16 Turbine Guide Bearing For the lump sum of $
B-16 48 13 17 Generator Bearings Refurbishment
For the lump sum of $
B-17 48 13 43 Rehabilitation of Generator Brake Ring
For the lump sum of $
B-18 48 13 43 Rehabilitation of Generator Brake and Jack Cylinder Assemblies
For the lump sum of $
B - 5
PRICE SCHEDULE B – Generator G2
CLIN Section Supplies or Services Quantity and Unit
Unit Price
Amount
B-19 48 13 43 Brake Dust Collection System
For the lump sum of $
B-20 48 13 44 Thrust Bracket Inspections 305 lin ft $ $
B-21 48 13 44 Thrust Bracket Coatings For the lump sum of $
B-22 48 13 57 Rotor Inspections 600 lin ft $ $
B-23 48 13 57 Rotor Coatings For the lump sum of $
B-24 48 13 62 Remove and Dispose of Armature Winding
For the lump sum of $
B-25 48 13 63 Preparing and Testing Existing Stator Core
For the lump sum of $
B-26 48 13 71 Furnish and Factory Test New Armature Winding
For the lump sum of $
B-27 48 13 71 Install and Field Test New Armature Winding
For the lump sum of $
B-28 48 13 72 Replace Generator Air Baffles
For the lump sum of $
B-29 48 13 93 Generator Neutral Grounding Equipment
For the lump sum of $
TOTAL FOR PRICE SCHEDULE B $_________________
B - 6
PRICE SCHEDULE C, OPTIONAL – Generator G1
CLIN Section Supplies or Services Quantity and Unit
Unit Price
Amount
C-1 48 13 16 Rebabbitt Turbine Guide Bearing
For the lump sum of $
C-2 48 13 17 Rebabbitt Generator Guide Bearing
For the lump sum of $
C-3 48 13 17 Rebabbitt Thrust Bearing Shoes
For the lump sum of $
C-4 48 13 17 Generator Thrust Runner For the lump sum of $
C-5 48 13 17 Thrust Bearing Springs For the lump sum of $
C-6 48 13 44 Thrust Bracket Repairs – Excavation
125 in3 $ $
C-7 48 13 44 Thrust Bracket Repairs - Weld
25 lb $ $
C-8 48 13 57 Rotor Repairs – Excavation 125 in3 $ $
C-9 48 13 57 Rotor Repairs – Weld 25 lb $ $
TOTAL FOR PRICE SCHEDULE C $_________________
B - 7
PRICE SCHEDULE D, OPTIONAL – Generator G2
CLIN Section Supplies or Services Quantity and Unit
Unit Price
Amount
D-1 48 13 16 Rebabbitt Turbine Guide Bearing
For the lump sum of $
D-2 48 13 17 Rebabbitt Generator Guide Bearing
For the lump sum of $
D-3 48 13 17 Rebabbitt Thrust Bearing Shoes
For the lump sum of $
D-4 48 13 17 Generator Thrust Runner For the lump sum of $
D-5 48 13 17 Thrust Bearing Springs For the lump sum of $
D-6 48 13 44 Thrust Bracket Repairs – Excavation
125 in3 $ $
D-7 48 13 44 Thrust Bracket Repairs – Weld
25 lb $ $
D-8 48 13 57 Rotor Repairs – Excavation 125 in3 $ $
D-9 48 13 57 Rotor Repairs – Weld 25 lb $ $
TOTAL FOR PRICE SCHEDULE D $_________________
B - 8
B.2 WARRANTED CHARACTERISTICS
(a) The Offeror warrants that the losses of winding and stator core for each generator shall not exceed the loss requirements furnished below, with rated voltage and frequency.
(b) Generator Rewind losses:
(1) Armature winding I2R losses at 13.8 kV, 60 Hz, 192,000 kVA,
1.0 power factor, at 95 degrees C, will not exceed _______kW*
* Offers indicating a warranted value in excess of 665 kW, will not be considered for award.
(c) Failure to furnish the required values will result in an incomplete offer, which will not be considered.
(d) Offers will be evaluated in accordance with the provision at WBR 1452.246-80, Evaluation of Equipment Efficiency and Losses.
(e) The contract price may be adjusted in accordance with the clause at WBR 1452.246-81, Failure to Meet Performance Warranties.
END OF SUPPLIES OR SERVICES AND PRICES/COSTS
Central Valley Project, California Solicitation No.
Table of Contents 00 01 10 - 1
SECTION C - DESCRIPTION / SPECIFICATIONS
TABLE OF CONTENTS
DIVISION 01 - GENERAL REQUIREMENTS
01 11 00 Summary of Work 01 14 10 Use of Site 01 14 12 Work Restrictions 01 14 30 Interruption of Service 01 31 22 Coordination Meetings 01 31 30 Contract Document Management System 01 32 10 Construction Program 01 33 00 Submittals 01 33 26 Electrical Drawings and Data 01 35 10 Safety Data Sheets 01 35 20 Safety and Health 01 35 30 Contractor’s Onsite Safety Personnel 01 35 50 Site Security 01 42 10 Reference Standards 01 46 00 Quality Procedures 01 51 00 Temporary Utilities 01 52 10 Field Office 01 54 20 Use of Government Crane 01 55 00 Vehicular Access and Parking 01 56 10 Protection of Existing Installations 01 56 15 Protection of Existing Utilities 01 57 20 Environmental Controls 01 57 30 Water Pollution Control 01 60 00 Product Requirements 01 74 00 Cleaning and Waste Management 01 78 30 Project Record Documents
DIVISION 02 - EXISTING CONDITIONS
02 80 10 General Requirements for Asbestos Abatement 02 80 11 General Requirements for Hazardous Materials Abatement 02 82 20 Removal and Disposal of Asbestos Containing Materials 02 83 35 Removal and Disposal of Coatings and Equipment with Coatings Containing
Regulated Metals 02 83 37 Removal and Disposal of Mercury Containing Equipment 02 87 20 Removal and Disposal of Used Oil
DIVISION 03 - CONCRETE
Central Valley Project, California Solicitation No.
Table of Contents 00 01 10 - 2
03 30 00 Cast-In-Place Concrete 03 62 20 Nonshrink Grout for Equipment and Metalwork
DIVISION 09 - FINISHES
09 96 20 Coatings
DIVISION 22 – PLUMBING
22 10 04 Removal of Equipment 22 10 12 Plant Auxiliary Piping and Appurtenances 22 11 24 Unit Cooling Water Pumps 22 11 83 Automatic, Self-Cleaning Strainer 22 11 85 Generator Air Coolers
DIVISION 26 - ELECTRICAL
26 05 02 Basic Electrical Materials and Methods 26 05 10 Conductors and Cables 26 05 20 Grounding and Bonding 26 05 33 Electrical Conduit 26 05 90 Wiring Checkout and Tests 26 09 12 Medium-Voltage Potential Transformers
DIVISION 28 – ELECTRONIC SAFETY AND SECURITY
28 23 00 Video Surveillance System
DIVISION 48 - ELECTRICAL POWER GENERATION
48 13 03 General Testing Methods 48 13 04 Disassembly and As-Found Readings 48 13 07 Reassembly and Alignment 48 13 08 Commissioning 48 13 09 Critical Connection Fasteners 48 13 16 Turbine Guide Bearing 48 13 17 Generator Bearings 48 13 18 Rebabbitt Bearings 48 13 43 Brake and Jacking System 48 13 44 Thrust Bracket Inspections 48 13 57 Rotor Inspections 48 13 62 Armature Winding Removal 48 13 63 Existing Stator Cores 48 13 71 New Armature Windings 48 13 72 Generator Ventilation Design Study 48 13 93 Generator Neutral Grounding Equipment
Table of Contents
00 01 10 - 3
DIVISION 51 - INFORMATION AVAILABLE TO OFFERORS
51 00 00 Information Available to Offerors 51 00 10 Contractor Use Areas 51 00 20 New Melones Photographs 51 00 50 Electronic Media Release 51 02 82 Hazardous Materials Survey and Analytical Results 51 48 73 Thermal Imaging Reports
DIVISION 52 - DRAWINGS
52 00 00 Drawings
END OF CONTENTS
Table of Contents
00 01 10 - 4
This page intentionally left blank.
Central Valley Project, California Solicitation No.
Summary of Work 01 11 00 - 1
SECTION 01 11 00
SUMMARY OF WORK
PART 1 GENERAL
1.01 LOCATION
A. Work is located at New Melones Powerplant approximately 50 miles east of Stockton, CA and 10 miles southwest of Sonora, CA in Calaveras County.
1.02 PRINCIPAL COMPONENTS OF WORK
A. Rewind and uprate the two main synchronous generators from 166,667kVA to nameplate 192,000 kVA.
B. Furnishing and installing video monitoring.
C. Performing as-found readings.
D. Generator disassembly.
E. Generator inspection.
F. New Armature Windings and Existing Stator Core:
1. Furnishing and installing stator armature bars, circuit ring bus, and main and neutral bus.
2. Preparing and testing existing stator cores, core loop test, making necessary repairs, and re-run core loop test.
G. Generator Monitoring and Instrumentation:
1. Furnishing and installing generator neutral current transformers, exciter and split-phase current transformers, potential transformers, armature winding RTDs, stator air gap sensors, generator flow and pressure switches, generator thrust bearing oil level and flow switches.
H. Optional re-babbiting of turbine and generator bearings.
I. Replace generator air baffles.
J. Auxiliary Generator Equipment:
1. Furnishing and installing generator space heaters, thermostat and associated wiring.
2. Furnishing and installing generator air coolers and associated piping.
Amendment 0006
Summary of Work
01 11 00 - 2
K. Perform Generator Ventilation Design Study and produce report.
1. Redesign and implement design changes.
L. Generator re-assembly.
M. Commissioning.
N. Furnishing and installing generator neutral grounding transformer, and inspection of neutral grounding transformer cable.
1.03 SPECIFICATIONS REQUIREMENTS
A. Requirements in Division 1, General Requirements, apply to Divisions 2 through 52.
B. Imperative statements in these specifications are Contractor requirements, unless otherwise stated.
C. Where specifications are written in streamlined form, words “shall be” are included by inference where a colon (:) is used within sentence or phrase.
1.04 DEFINITIONS
A. When specifications use a word or term defined in Federal Acquisition Regulations (FAR), definition of the word or term shall be in accordance with FAR sections in effect at the time solicitation was issued.
1.05 ACRONYMS
A. The following acronyms apply to specifications Divisions 1 through 52:
1. CO: Contracting Officer.
2. COR: Contracting Officer’s Representative.
3. OGR: Onsite Government Representative.
4. CE: Construction Engineer.
5. TSC: Technical Service Center.
PART 2 PRODUCTS
Not Used
PART 3 EXECUTION
Not Used
Summary of Work
01 11 00 - 3
END OF SECTION
Central Valley Project, California Solicitation No.
Submittals 01 33 00 - 1
SECTION 01 33 00
SUBMITTALS
PART 1 GENERAL
1.01 MEASUREMENT AND PAYMENT
A. Cost:
1. Include in prices offered in the Price Schedules for other items of work.
1.02 REFERENCE STANDARDS
A. American Society of Mechanical Engineers (ASME)
1. ASME Y14.1-12 Decimal-inch Drawing Sheet Size and Format
B. National Institute of Building Sciences (NIBS)
1. NIBS NCS-14 United States National CAD Standards, Version 6
1.03 DEFINITIONS
A. Days: Calendar days.
B. Required Submittal Number (RSN): Identifies items to be submitted together as a complete submittal.
C. As-built Drawings
1. Set of full-size, hard-copy drawings that contain both Government drawings furnished with this contract and Contractor-produced drawings necessary to clearly identify as-built conditions of the completed project.
D. Final Drawings
1. Complete electronic set of drawings produced by the Contractor as required by these specifications, updated to reflect all changes made in the field during construction.
E. Operations and Maintenance (O&M) Manuals
1. Final documentation for functional elements, equipment and systems installed in the finished work, including all information necessary for Government personnel to operate, maintain, and troubleshoot such elements, equipment and systems in a safe, clear, effective, and efficient manner. Include instructions, final drawings and equipment certifications for each element of work.
Submittals
01 33 00 - 2
F. Design Calculations
1. Calculations and verifications specified in the government-furnished contract documents. Design calculation and technical requirements are described in relevant specification sections.
2. Design calculations shall be certified by a registered professional.
G. Submittals are considered “shop drawings” within the terms of the clause at FAR 52.236- 21, Specifications and Drawings for Construction.
1.04 SUBMITTAL REQUIREMENTS
A. In case of conflict between requirements of this section and requirements included elsewhere in these specifications, requirements included elsewhere take precedence.
B. General:
1. Prepare in English.
2. Label with contract number and title, and RSN.
3. Measurement Units: US Customary Units.
4. Provide a unique sequential numbering extension for identification of each RSN resubmittal.
5. Provide a brief summary of what is included in the submittal and for what facility/unit.
C. Drawings:
1. Minimum Identification in Title Block:
a. Contract number and title.
b. Contractor’s or supplier’s title and drawing number.
c. Name of responsible party.
d. Date of original drawing.
e. Revision identification.
f. Date(s) of revision and revision description.
2. Reserve 3- by 3-inch space next to title block for review stamps at bottom right corner.
3. Size: D size (22 inches by 34 inches) as defined by ASME Y14.1.
4. Draw to scale using computer drafting or drafting equipment, unless otherwise specified.
a. Lettering and line work shall be neat when drawing preparation with drafting equipment is allowed.
01 33 00 - 3
b. Computer drafted drawings:
1) In accordance with NIBS NCS.
2) Electronic file format: Compatible with AUTOCAD, Version 2018 or later.
3) Compile using “eTransmit” utility in AUTOCAD.
5. Drawings Designated as “Government Format” in Specifications:
a. Computer drafted.
b. Government will provide an electronic AutoCAD format template.
c. Title block and sheet format:
1) As shown on standard drawing 40-D-7102.
2) Government will provide template.
3) Government will provide specific title block information to be used.
6. As-built Drawings: Refer to Section 01 78 30, Project Record Documents.
7. Final Drawings:
a. Computer drafted.
1) AUTOCAD format (.dwg) version 2018 or later.
b. Government will provide an electronic AUTOCAD format template.
c. Title block and sheet format:
1) As shown on standard drawing 40-D-7102.
d. Show changes, including revision dates, made during installation. Indicate changes by clouding with revision description in the titleblock.
e. As-built changes shall be signed off by the design engineer that any field change that was different from the approved design does not affect the design.
8. Electronic Files: On CD or DVD discs.
D. Product Data:
1. Mark manufacturer's data for commercial products or equipment, such as catalog cut sheets.
a. Identify manufacturer's name, type, model, size, and characteristics.
b. Illustrate that product or equipment meets requirements of specifications.
c. Mark items to be furnished in a manner that will photocopy (no highlighter).
d. Strike through items that do not apply.
01 33 00 - 4
E. Certifications:
1. Certifications by a Registered California Professional: Signed and sealed by a Professional Engineer with the appropriate discipline registered in the State of California and with the knowledge and experience of codes and design in the field in which they are signing.
2. Manufacturer’s Certifications: Signed by authorized representative of manufacturer.
F. Manuals:
1. Copies:
a. Printed copies: Bound and indexed and include Table of Contents, assembled into one or more books with enclosing covers.
1) Use double-sided copying for all multi-page data, brochures, manuals, documents, etc. Do not double-side drawings or pages that include graphs.
2) Binders: 3-ring; 1-inch ring size minimum.
b. Electronic copies: Adobe pdf on CD or DVD discs.
1) Bookmark files to assist in navigating.
2) Conform to print copies.
2. Contents:
a. Index sheet at front of each book which provides page or index tab number information for each device or item of equipment in book.
b. Complete parts identification lists for replacement, lists of special tools, and accessories, including list of recommended spare parts and components.
c. Schematics and wiring diagrams, as applicable.
d. Manufacturer’s full-size circuit breaker and fuse time-current curves, as applicable.
e. Copies of all factory test reports.
f. Copies of bills of materials
g. Copies of all drawings.
1) Final Drawings of equipment and systems.
2) As-built Drawings.
3) Maximum size: 11- by 17-inch.
h. Manufacturer’s operation and maintenance procedures; installation details, as necessary; and catalog data sheets for each device or item of equipment.
01 33 00 - 5
i. Photographs and test records or reports if required by the specifications.
j. Include one (1) copy in electronic format, Microsoft Office or PDF compatible, on DVD disc, with each hard copy manual.
G. Sample and Color Selection Submittals:
1. Label with complete manufacturer's product identification.
2. Include type and quantity of materials specified in the referenced section in each “set” of samples.
3. Samples: Representative of product to be installed. Xerographic sheets for color selection are not acceptable.
4. Color chips: Actual paint color chips or chart. Ink color reproductions are not acceptable.
5. Label each sample, sample kit, set of color chips, or color chart with contract number and title.
1.05 SUBMITTALS PROCEDURES
A. Submit only checked submittals. Submittals without evidence of Contractor's approval will be returned for resubmission.
B. Submit complete sets of required materials for each RSN as specified in “Submittals Required” column in Table 01 33 00A - List of Submittals. A complete set includes listed items for RSNs with multiple parts. Incomplete submittals will not be reviewed and will be returned to Contractor indicating submittal as incomplete.
C. Submit sets specified in “Sets to be sent:” columns in Table 01 33 00A – List of Submittals.
1. Submittals identified with “CDMS” in the “Sets to be sent” column shall be submitted electronically in accordance with Section 01 31 30 – Contract Document Management System (CDMS).
D. Include the following information in transmittal letters:
1. Contract number and title.
2. RSN for each attached submittal.
3. Responsible code.
4. Number of sets for each RSN.
5. Identify submittal as initial or resubmittal.
E. Resubmittal of submittals other than approved or accepted:
1. Mark changes such that they are readily identifiable and show revision date.
2. Describe reasons for significant changes in transmittal letter.
01 33 00 - 6
3. Resubmit returned submittals within 21 days after receiving the comments, unless otherwise directed.
4. Requirements for initial submittals apply to resubmittals.
1.06 REVIEW OF SUBMITTALS
A. Time Required:
1. Submittal review will require 28 days for review of each submittal or resubmittal, unless otherwise specified.
2. Time required for review of each submittal or resubmittal begins when complete sets of materials required for a particular RSN are received and extends through return via CDMS or mailing postmark date. Submittals uploaded to CDMS after normal business hours will be marked received the next business day.
B. Time in Excess of Specified:
1. CO may extend contract completion date to allow additional time for completing work affected by excess review time.
a. Time extension will be to extent that excess review time caused delay to contract completion date.
b. Time extension will not exceed time used in excess of specified number of days for review of submittals or resubmittals.
c. Concurrent days of excess review time resulting from review of 2 or more separate submittals or resubmittals will be counted only once in extending contract completion date.
2. No time extension will be allowed if Contractor fails to make complete action submittals in sequence and within time periods specified.
3. Adjustment for delay will be made only to the extent that:
a. Approval was required under the contract, and.
b. Requests for approval were properly and timely submitted and were approved.
4. Adjustment will be subject to terms of paragraphs (b) and (c) of clause at FAR 52.242-14, Suspension of Work; however, no such delay shall be deemed to be a “suspension order” as term is used in that clause. Adjustment will be subject to terms of clause at FAR 52.247-17, Government Delay of Work.
C. Return of Submittals:
1. Return of submittals will be by CDMS response or hard copy, as applicable.
2. Submittals will be returned either approved, conditionally approved, not approved, accepted, conditionally accepted, or not accepted.
3. Revise and resubmit submittals not approved or accepted as instructed.
01 33 00 - 7
1.07 HARD COPY TRANSMITTALS
A. Addresses for codes listed in Table 01 33 00A - List of Submittals:
1. Construction Engineer (CE), Bureau of Reclamation, Willows Construction Office, Attn: WCO-100, 1140 West Wood Street, Willows, CA 95988-2615.
2. Onsite Government Representative (OGR) contact information to be provided at Notice to Proceed.
3. Area Manager (AM), Bureau of Reclamation, Central California Area Office, 7794 Folsom Dam Road, Folsom, CA 95630
4. Technical Service Center (TSC), Bureau of Reclamation, Attn: 86-68170, P.O.
Box 25007, Denver CO 80225-0007; Express Mail: Sixth and Kipling, Building 67, Room 152.
B. Send original transmittal letter with appropriate number of sets to office listed in “Responsible Code” column in Table 01 33 00A - List of Submittals.
1. Responsible codes starting with “86-6” are located in Technical Service Center.
Send these submittals to the TSC address shown above.
C. Send copy of transmittal letter with appropriate number of sets to offices that are not responsible code, but show “Sets to be sent” in Table 01 33 00A - List of Submittals.
D. When “Sets to be sent” is 0, send a copy of transmittal letter to that office.
E. Submittals identified with “CDMS” in No. of sets to be sent to”: Column of Table 01 33 00A – List of Submittals, shall be submitted in electronic format in accordance with Section 01 31 30 – Contract Document Management System (CDMS) except for the following:
1. Government, at discretion of COR, may require Contractor to provide complete hardcopy submittals which appear unclear or illegible in electronic format.
F. Submittals required by specifications, but not listed in Table 01 33 00A - List of Submittals:
1. Submit in accordance with this section.
2. Submit to CE, unless otherwise specified.
PART 2 PRODUCTS
Not Used
PART 3 EXECUTION
Not Used
01 33 00 - 8
Table 01 33 00A. - List of Submittals
* CE indicates Construction Engineer, OGR indicates Onsite Government Representative, AM indicates Area Manager, and TSC indicates Technical Service Center. CDMS indicates Contract Document Management System. One hard copy of each CDMS RSN shall be sent to the CE.
RSN
Clause or
Section Title
Submittals required Due date or delivery time
Respon-sible code
Sets to be sent: *
CE OGR AM
TSC
01 14 10-1 Use of Site Land Use and Landscape Rehabilitation Plan
Submitted and approved before starting onsite work
CE CDMS
01 14 30-1 Interruption of Service
Interruption of Service Requests
Submitted at least 30 days before each interruption of service required
CE CDMS
01 31 30-1 Contract Document Management System
Approval Data Submitted within 7 days after receiving Notice of Award and approved before implementation
CE 2 1 1 1
01 31 30-2 Contract Document Management System
Final Data Submitted within 21 days after completing the work
CE 2 1 1 1
01 32 10-1 Construction Program
Representative Information
Submitted within 7 days after CDMS implementation
CE CDMS
01 32 10-2 Construction Program
Baseline Schedule Submitted within 14 days after CDMS implementation
CE CDMS
01 32 10-3 Construction Program
Updated Schedule Reports
Submitted to coincide with associated pay requests to confirm progress, otherwise, monthly
01 32 10-4 Construction Program
Time Impact Analysis
Submitted in response to CO-directed changes, contractor proposed changes, value engineering proposals, or any requests or claims for equitable adjustments
01 35 10-1 Safety Data Sheets
Complete LHM and
SDS
Submitted at least 14 days before initial jobsite delivery of hazardous material
CE CDMS
01 35 10-2 Safety Data Sheets
Updated LHM and
SDS
Submitted at least 14 days before jobsite delivery of hazardous material not previously listed
CE CDMS
01 35 20-1 Safety and Health
Safety Program Submitted and accepted before starting onsite work (See Section 3 of RSHS)
CE CDMS
01 35 20-2 Safety and Health
Monthly Accident Summary Report
Submitted the first day of each…