Atch06_06-16-2026_WO_297_YNP_Rangers_Club_Annual_Dry_Amendment_0001_0001.pdf
PDF 627 KB Posted
- Solicitation number
- 140P8526Q0110
About this file
This is an Inspection, Testing, and Maintenance Report for a fire protection system at the YNP Rangers Club in Yosemite, California, conducted in accordance with NFPA 25 as amended by California Code of Regulations, Title 19.
The property inspected is the YNP Rangers Club, a Type V-A construction building with 2 stories, built in 1920, located at P.O. Box 577, Yosemite, California 95389. The contact is Stephanie Bartholomew (209-628-0186). The inspection was performed by Granite Fire Protection, Inc. (CA License #1088467, Job #297), with inspector Eusebio "JR" Aguilar conducting the work on June 16, 2026. The report was sent to the property owner and contractor on that same date. The inspection focused on the Automatic Sprinkler System (NFPA 25 Chapter 5) with one system riser located in the basement. The system is a dry pipe configuration with a 4-inch riser diameter and 2-inch main drain diameter. The main drain test recorded initial static pressure of 106 psi, residual pressure of 82 psi, and final static pressure of 106 psi, all passing. Quarterly and annual inspections and tests were completed on June 16, 2026, with all items marked as Pass or N/A (Not Applicable). Specific operational parameters recorded include: compressor start at 30 psi, compressor stop at 40 psi, air pressure at 40 psi, supply pressure at 106 psi, valve trip time of 18 seconds, and trip pressure of 19 psi. No deficiencies were identified. The system was returned to service and certified as fully operable and compliant with CCR Title 19, Sections 901 to 906.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Inspection, Testing, and Maintenance Cover Sheet NFPA25 as amended by CCR, Title 19
Property Information:
Name: Occupancy/Use:
Address: Construction Type:
City: No. Stories:
ZIP: Year Constructed:
Contact:
Telephone:
Contractor Information: Number of System Risers
Name: Copy sent to:
Address: Owner Date:
City: Fire AHJ Date:
State: Contractor Date:
Telephone:
NOTES:
1) For specific inspection, testing, and maintenance requirements and information, see NFPA 25, 2011 Edition as amended by California Code of Regulations, Title 19, §901 to §906.
2) Inspection items may be performed by the owner in accordance with California Code of Regulations, Title 19, §904.1(a)
CA License#:
Job #:
Performed by:
Check box for each system inspected and enter the number of forms used for inspection.
Check boxes (Fail or Pass) to indicate status of inspected system at end of inspection.
Forms Included with this Report NFPA 25 Chapter Number of Forms N/A Fail* Pass
Automatic Sprinkler System 5
Standpipe and Hose System 6
Private Water Supply System 7
Fire Pump 8
Water Storage Tank 9
Water Spray System 10
Foam Water Sprinkler System 11
Water Mist System 12
Concerns that are not deficiencies (i.e. Non-Sprinklered Areas) Yes No
*See "Deficiencies and Comments" section at end of each respective form.
AES 1 September 3, 2013
YNP Rangers Club
Yosemite, California
Type V-A
209-628-0186
P.O. Box 1963
Oakhurst
Granite Fire Protection, Inc.
(559)676-5094
CA ✔
✔ 06/16/26
06/16/26
Eusebio "JR" Aguilar
1088467
R2
Superintendent, P.O Box 577
Stephanie Bartholomew
95389 1920
Dry Pipe Fire Sprinkler System
California Code of Regulations - Title 19 Inspection, Testing, and Maintenance
Quarterly and Annual Report 1 of 3
Property Information Contractor or Licensed Owner Information
Building Name Name
Address Address
City St. Zip
City License # Phone
Contact Person SFM Job # CSLB Misc.
Riser Information Main Drain Test (Annual) Riser No. Location Riser
Diameter Main Drain Diameter
Initial Static Pressure
Residual Pressure
Final Static Pressure P,F,N/A
This building has more than 5 risers. See additional AES 2.9 form attached Number of AES 2.9 orms attached
Quarterly Inspections I = Inspection T = Test M = Maintenance P = Pass F = Fail N/A = Not Applicable
Item Description NFPA 25 CA ed.
Reference
Date Date Date Date
1.1 I Control Valves – Identification Sign 13.3.1
1.2 I Control Valves – Inspection 13.3.2
1.3 I Waterflow Alarm Devices 5.2.5
1.4 I Supervisory Devices 5.2.5
1.5 I Gauges (Dry Pipe Systems)
Pass = Normal Pressures
5.2.4.2, 5.2.4.3 5.2.4.4
13.4.4.1.2
1.6 I Air 3ressure
5.2.4.2, 5.2.4.3
5.2.4.4 13.4.4.2.5.1 psi psi psi psi
1.7 I Water 6upply 3ressure
5.2.4.2
13.4.4.2.5.1 psi psi psi psi
1.8 I Hydraulic Design Information Sign
(for hydraulically designed systems) 5.2.6
1.9 I General Information Sign
(not required for system prior to 2007 edition of NFPA 13) 5.2.8
1.10 I Heat Tape 5.2.7
1.11 I Spare Sprinklers 5.2.1.4
1.12 I Fire Department Connections 13.7
1.13 I Dry Pipe Valves – Exterior Inspection 13.4.4.1.4
1.14 I Pressure Reducing Valves 13.5.1
1.15 Backflow Preventers 13.6.1
1.16 PRV – Fire Sprinkler Systems 13.5.1
Form AES 2.3 Sept. 3, 2013
3KRQH
N/A
P
P
P
N/A
N/A
N/A
P
P
P
P
P
P
N/A
YNP Rangers Club
Yosemite
Stephanie Bartholomew
P.O. Box 1963
Oakhurst
Granite Fire Protection, Inc.
(559)676-5094
CA 93644
C-16
06/16/26
106106
1088467
2"
Annual Inspection
P
P.O Box 577
P.O Box 577
209-628-0186
824"Basement1
A037864
California Code of Regulations - Title 19 Inspection, Testing, and Maintenance
Quarterly and Annual Report 2 of 3
Property Information Contractor or Licensed Owner Information
Building Name Name
Address Job #
City
ANNUAL INSPECTION, TESTING, AND MAINTENANCE
Include ALL Quarterly Inspections (See Previous Page)
I = Inspection T = Test M = Maintenance P = Pass F = Fail N/A = Not Applicable
Item Description NFPA 25 CA ed.
Reference Date Comments Only P,F,N/A
1.17 I Buildings (Freeze 3rotection) 4.1.1.1 Owner’s Responsibility
1.18 I Sprinklers 5.2.1
1.19 I Pipe and Fittings 5.2.2
1.20 I Hangers 5.2.3
1.21 I Seismic Braces 5.2.3
1.22 I Small Hose Connections* 13.5.6.2.2
2.1 T Field Service Test Required
(Send Report to Fire Code Official) 5.3.1 If REQUIRED, Enter 'F' until results are returned from Lab
2.2 T Recalled Sprinklers
If not present = Pass; If present = Fail
Title 19 904.1(c)
2.3 T Water )low Alarm Devices
90 sec. maximum - (Enter Time )
5.3.3
13.2.6 sec.
2.4 T Main Drain Test
(Enter data on Page 1 of this form)
13.2.5 13.3.3.4
2.5 T Priming Water Level Test 13.4.4.2.1
2.6 T Dry Pipe Valve Trip Test
(Partial trip test is acceptable)
13.4.4.2.2 13.4.4.2.2.3 13.4.4.1.5
2.7 T Valve Trip Time 13.4.4.2.5.2 sec.
2.8 T Trip Air Pressure 13.4.4.2.5.1 psi
2.9 T Quick-Opening Device Test 13.4.4.2.4
2.10 T Low Air Pressure Alarm Test 13.4.4.2.6
2.11 T Low Temperature Alarm Test 13.4.4.2.7
2.12 T Automatic Air Pressure Maintenance Device Test 13.4.4.2.8
2.13 T Control Valve – Operation 13.3.3
2.14 T Valve Supervisory Devices 13.3.3.5
2.15 T Backflow Preventer Assemblies 13.6.2
2.16 T PRV – Partial Flow 13.5.1.3
* Small hose connections are hose valves and optional hose supplied by the fire sprinkler system. They do not include Class I, II, or III standpipe systems.
Form AES 2.3 Sept. 3, 2013
06/16/26 N/A
06/16/26 P
06/16/26 P
06/16/26 P
06/16/26 P
06/16/26 N/A
06/16/26 N/A
06/16/26 N/A
06/16/26 N/A
06/16/26 P
06/16/26 N/A
06/16/26 N/A
06/16/26 N/A
06/16/26 N/A
06/16/26 P
06/16/26 P
06/16/26 P
06/16/26 N/A
06/16/26 P
06/16/26 P
06/16/26 P
06/16/26 N/A
YNP Rangers Club
Yosemite
Granite Fire Protection, Inc.
P.O Box 577
California Code of Regulations - Title 19 Inspection, Testing, and Maintenance
Quarterly and Annual Report 3 of 3
Property Information Contractor or Licensed Owner Information
Building Name Name
Address Job #
City
ANNUAL INSPECTION, TESTING, AND MAINTENANCE
Include ALL Quarterly Inspections (See Quarterly Inspections Page)
I = Inspection T = Test M = Maintenance P = Pass F = Fail N/A = Not Applicable
Item Description NFPA 25 CA ed.
Reference Date Comments Only P,F,N/A
3.1 M Control Valves 13.3.4
3.2 M Maintenance 13.4.4.3
3.3 M Dry Pipe Valve Interior Cleaned 13.4.4.3.1
3.4 M Low 3oints in 6ystem 'rained 13.4.4.3.2
3.5 M Backflow Preventer 13.6.3
3.6 M
Obstruction Investigation 5equired (If “Yes”, see Deficiencies and Comments Section for Results.)
14.3 Yes No
3.7 M System 5eturned to 6ervice 4.5.3
15.7
Yes No
D = Deficiency C = Comment (Indicate type )
Item Date Riser D C Deficiencies and Comments Indicate all equipment, devices and parts that were repaired or replaced
Check here if additional Deficiencies and Comments are listed on Form AES9
See Correction Form AES 10 for corrected deficiencies.
Number attached� Number attached�
I hereby certify that the fire protection equipment listed above has been fully inspected, tested, and maintained on this date by the company indicated above, in accordance with CCR, Title 19, Sections 901 to 906 and that the equipment is fully operable except as noted in the “Deficiencies and Comments” section of this form.
Quarter
Check box if Annual Inspection, Testing & Maintenance ,tems are &ompleted in the ,ndicated Quarter Annual 4th Annual
Date
Print Name
Signature
Form AES 2.3 Sept. 3, 2013
Annual Annual1st �QG �UG �tK
06/16/26 P
06/16/26 P
06/16/26 P
06/16/26 P
06/16/26 N/A
06/16/26 N/A
06/16/26 P
YNP Rangers Club
Yosemite
Granite Fire Protection, Inc.
✔06/16/26 Annual Inspection is completed, system is a PASS.
Compressor start = 30 psi Compressor stop = 40 psi
Air pressure = 40 psi Supply = 106 psi Trip time = 18 seconds Trip pressure = 19 psi
P.O Box 577
Deficiencies - Cover Sheet
None
Deficiencies - Quarterly/Annual Dry Pipe
None
Report of Inspection / Test
06-19-2026 Property YNP Rangers Club
Conducted by: Eusebio "JR" Aguilar
Granite Fire Protection, Inc.
1088467 P.O. Box 1963 Oakhurst CA 93644 (559)676-5094
Copyright 2026 Inspect Point
Inspector Signature
I state that the information on this form is correct at the time and place of my inspection, and all equipment tested at this time was left in operational condition upon completion of this inspection except as noted.
Inspector Name Signature Date Completed
Eusebio "JR" Aguilar 2026-06-19
Report of Inspection / Test
06-19-2026 Property YNP Rangers Club
Conducted by: Eusebio "JR" Aguilar
Granite Fire Protection, Inc.
1088467 P.O. Box 1963 Oakhurst CA 93644 (559)676-5094
Copyright 2026 Inspect Point
File details come from the government source that posted it. Updated .