B09 - Amendment5Attachment29_S101_0005.pdf
PDF 215 KB Posted
- Attached to
- Remove and Install a New HVAC unit. Federal contract opportunity
- Solicitation number
- 140P6220B0002
About this file
This document package includes structural plans and details for construction work as well as information on an associated federal contract opportunity. The structural plans outline the foundation plan, framing plan, exterior equipment pad detail, exterior masonry wall detail at concrete grade beam, steel lintel detail above an opening in an existing masonry wall, light gauge joist bearing and connection details at CMU walls, and metal decking and joist schedules. Relevant project details include replacing an existing HVAC system with a new geothermal fluid cooler and natural gas boiler near an existing maintenance building. The federal contract opportunity is from the Department of Interior National Park Service Midwest Region under solicitation number 140P6220B0002 to provide all labor, materials and equipment to complete the work, which includes disconnecting and replacing geothermal piping and heat pumps at a visitor center, along with adding energy recovery ventilators.
View the file
Other files for this federal contract opportunity
Show all 37
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
L -1
L -1
C .J
C
.J
T.O. SLAB
EL. SEE ARCH.
EL. = SEE PLAN
FIN. FLOOR
EL. = SEE PLAN
T.O.F.
@ 16" O.C.
600S250-43 LIGHT GAUGE JOISTS
OPEN
S101
S101
S101 5
S101
GB1-6
GB1-6
GB1-6
G B
-6
S101
S101
TYP.
S201
C12X20.7
C8X11.5
S201
GRANULAR FILL
UNDISTURBED SOIL
CONC. SLAB - SEE PLAN
EQUIPMENT - SEE PLAN
12" DEEP CONCRETE FOUNDATION PAD
W/ #5 @ 12" O.C. E.W. TOP & BOTTOM
NOTES:
1. CONTRACTOR SHALL ANCHOR EQUIPMENT PER EQUIPMENT
MANUFACTURER REQUIREMENTS USING HILTI KWIK BOLT III
EXPANSION ANCHORS OR HILTI HIT-HY 200 EPOXY ANCHORS.
2. CONTRACTOR SHALL VERIFY AND COORDINATE LENGTH AND
WIDTH OF PAD WITH EQUIPMENT MANUFACTURER.
3. CONTRACTOR SHALL VERIFY AND COORDINATE ALL OPENING
SIZES AND LOCATIONS REQUIRED IN FOUNDATION PAD.
PROVIDE DOWEL TO MATCH
AND LAP VERT. WALL REINF.
PAVING OR
FINISHED GRADE
AS OCCURS
CENTERLINE OF CMU WALL
= CENTERLINE OF FOOTING
CONC. FOOTING -
SEE PLAN & SCHED.
FOR SIZE & REINF.
GROUT BOTTOM
COURSE SOLID
CMU WALL - SEE PLAN &
SCHED. FOR SIZE & REINF.
1/2" EXPANSION JOINT
CONC. SLAB ON
GRADE - SEE PLAN
CMU WALL - SEE
PLAN AND SCHED.
FOR SIZE AND REINF.
ROOFING AND INSULATION -
SEE ARCH.
METAL DECKING - SEE PLAN &
SCHED. FOR SIZE & ATTACH.
LIGHT GAUGE
JOIST - SEE PLAN
CONT. RIM TRACK
8" BOND COURSE W/ (2)
#4 CONT. - GROUT SOLID
CONT. L4X4X3/8 ANGLE
W/ 1/2" DIA. HILTI KIWK
BOLT 3 ANCHORS @ 24"
O.C. (3 1/2" EMBED.)
(2) #10 SCREWS
@ EACH JOIST
CONT. 2X PLATE W/ 1/2" DIA.
HILTI KIWK BOLT 3 ANCHORS
@ 24" O.C. (3 1/2" EMBED.)
CMU WALL - SEE PLAN AND
SCHED. FOR SIZE AND REINF.
ROOFING AND INSULATION -
SEE ARCH.
METAL DECKING - SEE PLAN &
SCHED. FOR SIZE & ATTACH.
LIGHT GAUGE
JOIST - SEE PLAN
ATTACH JOIST TO CMU W/ (2)
HILTI X-U KNURLED SHANK
FASTENERS @ 12" O.C.
8" BOND COURSE W/ (2)
#4 CONT. - GROUT SOLID
CONT. 2X PLATE W/ 1/2" DIA.
HILTI KIWK BOLT 3 ANCHORS
@ 24" O.C. (3 1/2" EMBED.)
W8X15 STEEL LINTEL
3/4" BEARING PLATE OVER 3/4" NON-
SHRINK GROUT W/ (2) 1/2" DIA. HILTI
HIT-HY 270 EPOXY ANCHORS IN LONG
SLOTTED HOLES (4 1/2" EMBED.)
GROUT MASONRY CELL
BELOW LINTEL BEARING
SOLID (FULL HEIGHT)
EXIST. CMU
TOOTH IN NEW CMU
JAMB BLOCK EACH
END OF OPENING NEW WALL OPENING -
SEE ARCH. FOR EXTENTS
5/16" STEEL PLATE WHERE CMU
EXTENDS BEYOND BEAM FLANGE BY
MORE THAN 3/4" ON EITHER SIDE -
PLATE WIDTH SHALL BE 1" LESS THAN
WALL THICKNESS (FIELD VERIFY)
1 1/2" SOLID BLOCKS TO COVER
BEAM WHEN EXPOSED TO VIEW
(NOT SHOWN FOR CLARITY)
REMOVE AND REPLACE ADDITIONAL CMU
ABOVE WALL OPENING AS REQUIRED
FOR INSTALLATION OF STEEL LINTEL
EXISTING CMU WALL
ROOFING AND INSULATION -
SEE ARCH.
METAL DECKING - SEE PLAN &
SCHED. FOR SIZE & ATTACH.
LIGHT GAUGE
JOIST - SEE PLAN
ATTACH JOIST TO EXISTING
CMU W/ (2) HILTI X-U KNURLED
SHANK FASTENERS @ 12" O.C.
1044 North 115th Street | Suite 300
Omaha, NE 68154
(402) 493-4800 www.schemmer.com
REVISED TITLE OF SHEET DRAWING NO.
SHEET
PMIS / PKG. NO.
OF
SUB SHEET NO.
ARCH/ENG PROJ #
DESIGNED
DRAWN
CHECKED
PREPARED
DATE
241749
00000
FORT SMITH NATIONAL HISTORIC SITE
301 PARKER AVE
FORT SMITH, AR 72901C
U s e rs \e h o ff \D o c u m e n ts
\R e v it te m p \0
-S T
R U
C
R
-F O
S M e h o ff s c h e m m e r.
c o m .r v t
ECH
ECH
KMW
01/03/2020
07310.007
S101
PLANS & DETAILS
07310007FOSM- 3- S101 PLANS & DETAILS
PLAN NOTES:
REF. NOTES ( ):X
1 STRUCTURAL STOOP - SEE SHEET S102 FOR TYPICAL DETAIL. REFERENCE
ARCHITECTURAL DRAWINGS FOR STOOP DIMENSIONS.
2 4" CONCRETE SLAB ON GRADE W/ 6X6 W2.9XW2.9 W.W.F. OVER 4"
GRANULAR FILL. - TYP. REFERENCE ARCH DRAWINGS FOR SLOPE
REQUIREMENTS AS NEEDED.
3 'C.J.' INDICATES CONTROL JOINT - SEE TYPICAL DETAIL ON SHEET S201
4 DRILL & EPOXY LONG. FOOTING REINF. INTO EXIST FOOTING (6" MIN.
EMBED.)
5 1 1/2" 'B' 22 GA. METAL ROOF DECK. SEE METAL ROOF DECK SCHEDULE
FOR MORE INFORMATION
6 MECHANICAL EQUIPMENT MAX OPERATING WEIGHT OF 12,000 LBS.
7 EXISTING DOWNSPOUT WITH UNKNOWN PIPING LOCATION. CONTRACTOR
SHALL TAKE CARE TO CONSTRUCT FOOTINGS AROUND PIPE PER TYPICAL
DETAIL ON S201.
8 GALVANIZED SERRATED WELDED STEEL BAR GRATING (19W4) W/ 1"X1/8"
BEARING BARS AT 1 3/16" ON CENTER AND CROSS BARS AT 4" ON
CENTER. TYPICAL AT STAIR.
A. REFERENCE SHEET S01 FOR STRUCTURAL NOTES.
B. REFERENCE SHEET S201 FOR TYPICAL DETAILS NOT NECESSARILY
INDICATED ON PLAN.
C. VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS.
D. TOP OF FOOTING (T.O.F.) ELEVATION IS 109’-7”, TYPICAL U.N.O.
E. FINISHED FLOOR ELEVATION (F.F.E.) IS 110’-3”, TYPICAL U.N.O.
F. GRADE BEAMS ARE REQUIRED AT ALL EXTERIOR WALLS. BOTTOM OF
GRADE BEAM SHALL HAVE A MINIMUM DEPTH OF 24” BELOW EXTERIOR
GRADE.
G. STRUCTURAL STOOPS ARE REQUIRED AT ALL EXTERIOR SWING DOORS.
SEE TYPICAL DETAIL ON SHEET S201.
H. CONTRACTOR FIELD VERIFY EXISTING CONDITIONS AND NOTIFY ENGINEER
OF RECORD OF ANY DISCREPANCIES WITH CONSTRUCTION DOCUMENTS.
SCALE: 1/8" = 1'-0"
FRAMING PLAN
SCALE: 1/8" = 1'-0"
FOUNDATION PLAN
GRADE BEAM SCHEDULE
MARK WIDTH DEPTH LONGITUDINAL REINFORCING STIRRUPS
GB1-6 1' - 6" 2' - 0" (3) #5 BARS BOT., (3) #5 BARS TOP #4 @ 24" O.C.
MASONRY WALL REINF. SCHEDULE
MARK WIDTH
REINFORCING
VERTICAL HORIZONTAL
A 0' - 8" #5 @ 32" O.C. MAX. LADDER TYPE - 2 - W1.7 WIRES @ 16" O.C.
MASONRY LINTEL SCHEDULE
MARK BEARING REINFORCING
L-1 8" 16" BOND BEAM W/ (2) #5 CONT. @ BOT.
SCALE: 1/2" = 1'-0"
EXTERIOR EQUIPMENT PAD DETAIL
SCALE: 3/4" = 1'-0"
EXTERIOR MASONRY WALL AT CONCRETE GRADE BEAM
SCALE: 3/4" = 1'-0"
LIGHT GAUGE JOIST BEARING AT CMU WALL
SCALE: 3/4" = 1'-0"
LIGHT GAUGE JOIST AT CMU WALL
METAL DECKING SCHEDULE
LOCATION
DEPTH
(IN.)
GAUGE MIN. I MIN. S FINISH
CONNECTION TO
SUPPORTING MEMBERS
(#12 TEK SCREWS)
SIDE LAPS
(#10 SCREWS)
REMARKS
ROOF 1 1/2 22 0.155 0.186 GALVANIZED 36/4 PATTERN
(1) SIDE LAP FASTENERS
#10 TEK SCREWS - EA.
JOIST SPACE
TYPE "B"
SCALE: 3/4" = 1'-0"
STEEL LINTEL ABOVE NEW OPENING IN EXISTING MASONRY WALL
SCALE: 3/4" = 1'-0"
SECTION AT EXISTING WALL
NOTE: PROVIDE TYPE 'A' WALLS AT ALL CMU WALLS, TYPICAL U.N.O.
DATE INITIAL
08/12/2020 ECH
| Sheets |
| S101 - PLANS & DETAILS |
| S201 - TYPICAL DETAILS |
File details come from the government source that posted it. Updated .