About this file

This document contains construction drawings and schedules for a federal contract opportunity to remove and install a new HVAC system. Work will consist of disconnecting the existing geothermal piping loop from the Visitor Center HVAC system and replacing it with a new fluid cooler and natural gas boiler located near the Maintenance Building. Existing piping within the Visitor Center will be replaced as indicated on the drawings. The existing heat pumps and an attic ductless split system will be replaced with new heat pump units, and energy recovery ventilators will be added. The solicitation is issued by the National Park Service Midwest Region under number 140P6220B0002 to provide all labor, materials, tools and equipment for the HVAC replacement project at the Fort Smith National Historic Site located at 301 Parker Ave, Fort Smith, AR 72901.

View the file

Other files for this federal contract opportunity

Other files attached to Remove and Install a New HVAC unit., newest first.
File Type Posted
B09 - Amendment5Attachment27_A101_0005.pdf PDF
B09 - Amendment5Attachment26_087100_0005.pdf PDF
B09 - Amendment5Attachment31_QandA_0005.pdf PDF
B09 - Amendment5Attachment25_075323_0005.pdf PDF
B09 - Amendment5Attachment30_S201_0005.pdf PDF
Sol_140P6220B0002_Amd_0005.pdf PDF
B09 - Amendment5Attachment29_S101_0005.pdf PDF
B09 - Amendment4Atch13Parking_0004.pdf PDF
B09 - Amendment4Atch22UtilityDetails2000_0004.pdf PDF
B09 - Amendment4Atch24BrandNameJustification_0004.pdf PDF
B09 - Amendment4Atch15Section232500_0004.pdf PDF
Sol_140P6220B0002_Amd_0004.pdf PDF
B09 - Amendment4Atch21LowerLevelFloorPlan2000_0004.pdf PDF
B09 - Amendment4Atch16M200_Rev1_0004.pdf PDF
B09 - Amendment4Atch17M501_Rev1_0004.pdf PDF
B09 - Amendment4Atch14Section221429_0004.pdf PDF
B09 - Amendment4Atch23QuestionsandAnswers_0004.pdf PDF
B09 - Amendment4Atch20HVACPlanLowerLevel2000_0004.pdf PDF
B09 - Amendment4Atch18E103_Rev1_0004.pdf PDF
B09 - Amendment4Atch19HVACPipingPlans2000_0004.pdf PDF
Sol_140P6220B0002_Amd_0003.pdf PDF
Sol_140P6220B0002_Amd_0002.pdf PDF
140P6220B0002Amendment2Attachment_0002.pdf PDF
Base_B08 - SolicitationAtch3SenitiveAreaMap.pdf PDF
Base_B08 - SolicitationAtch9TechPic2.pdf PDF
Base_B08 - SolicitationAtch4Pictures1.pdf PDF
Base_B08 - SolicitationAtch10OF17.pdf PDF
Base_B08 - SolicitationAtch5SubmittalList.pdf PDF
Base_B08 - SolicitationAtch7WageDetermination.pdf PDF
Base_Sol_140P6220B0002.pdf PDF
Base_SolicitationAtch1Specifications06242020.pdf PDF
Base_B08 - SolicitationAtch11SF24BidBond.pdf PDF
Base_B08 - SolicitationAtch8TechPic1.pdf PDF
Amend_0001_Sol_140P6220B0002_Amd_0001.pdf PDF
Base_B08 - SolicitationAtch2Drawings.pdf PDF
Base_B08 - SolicitationAtch6CloseoutSubmittalList.pdf PDF
Base_B08 - SolicitationAtch12NoticetoContractorsCPARS.pdf PDF
Show all 37

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

2" SEE SCHEDULE 2"

S E

E S

C H

E D

U L E

2" SEE SCHEDULE 2"

S E

E S

C H

E D

U L E

F1

HOLLOW METAL

F2

HOLLOW METAL

SEE SCHEDULE

S E

E S

C H

E D

U L E

SEE SCHEDULE

S E

E S

C H

E D

U L E

4" 6"

F NV

HM FRAME

(PAINT)

-GROUT FULL

DOOR - SEE

SCHED.

SEALANT

BOTH SIDES

BOND BEAM - SEE STR

SEALANT BOTH

SIDES

CMU WALL

HM FRAME (PAINT)

-GROUT FULL

DOOR - SEE

SCHED.

DOOR - SEE SCHED

THRESHOLD SET IN SEALANT

STRUCTURAL STOOP - SEE STR

1/2" EXPANSION JOINT

HM FRAME

(PAINT)

DOOR - SEE

SCHED.

SEALANT

BOTH SIDES

STEEL BEAM

LINTEL - SEE STR

CMU SOAPS - BOTH

SIDES OF STL LINTEL

SEALANT BOTH

SIDES

EXIST CMU WALL

HM FRAME (PAINT)

DOOR - SEE

SCHED.

GROUT CMU CELL

CLOSED CELL BACKER ROD

W/ SEALANT - @ EXPOSED

TO VIEW LOCATIONS ONLY

REINFORCED CMU JAMB

BLOCK, GROUT SOLID,

SEE ELEV. FOR TYPE -

SEE STR

RUBBER CONTROL JOINT

DUR-O-WALL NO. 6 OR

APPROVED EQUAL

CLOSED CELL BACKER ROD

W/ SEALANT - @ EXPOSED

TO VIEW LOCATIONS ONLY

3/8"

1044 North 115th Street | Suite 300

Omaha, NE 68154

(402) 493-4800 www.schemmer.com

REVISED TITLE OF SHEET DRAWING NO.

SHEET

PMIS / PKG. NO.

OF

SUB SHEET NO.

ARCH/ENG PROJ #

DESIGNED

DRAWN

CHECKED

PREPARED

DATE

241749

00000

FORT SMITH NATIONAL HISTORIC SITE

301 PARKER AVE

FORT SMITH, AR 72901C

U s e rs \j fi e d le r\ D o c u m e n ts \R e v it te m p

\0

-A R

C H

R

-F O

S M jf ie d le r.

rv t

JLF

JLF

MJH

01/03/2020

07310.007

A301

SCHEDULES, DOOR AND

WINDOW DETAILS

07310007FOSM- 2- A301 SCHEDULES, DOOR AND WINDOW DETAILS

DOOR & FRAME TYPES

SCALE: 1/4" = 1'-0"

ROOM SCHEDULE

ROOM NO ROOM NAME

FLOOR

MATL

FLOOR

FINISH

BASE

MATL

CEILING NORTH WALL EAST WALL SOUTH WALL WEST WALL

REMARKSHEIGHT MATL FINISH MATL FINISH MATL FINISH MATL FINISH MATL FINISH

100 COOLING TOWER

ENCLOSURE

CONC SEALED -- -- -- -- CMU P CMU P CMU P EXIST EXIST

1, 2

101 BOILER SHED CONC SEALED -- VARIES EXP STR -- CMU P CMU P CMU P EXIST EXIST 1, 2

DOOR SCHEDULE

DOOR NO

DOOR SIZE DOOR FRAME DETAIL

SET NO REMARKSWIDTH HEIGHT THICK TYPE MATL GLASS TYPE MATL HEAD JAMB JAMB SILL

100-2 PR 3' - 0" 7' - 0" 0' - 1 3/4" F HM -- F2 HM 1/A301 2/A301 2/A301 3/A301 1 1

101-1 3' - 0" 7' - 0" 0' - 1 3/4" F HM -- F2 HM 4/A301 5/A301 5/A301 -- 3 1

101-2 PR 3' - 0" 7' - 0" 0' - 1 3/4" F HM -- F2 HM 1/A301 2/A301 2/A301 3/A301 1 1, 2

DOOR SCHEDULE REMARKS

1. INTRUSION ALARM - COORDINATE DOOR HARDWARE W/ NPS ALARM PROVIDER FOR INSTALLATION AND WIRING REQUIREMENTS

2. INSULATED

ROOM SCHEDULE REMARKS

1. HOLLOW METAL DOORS AND FRAMES TO BE PAINTED TO MATCH CMU.

2. INTERIOR AND EXTERIOR SIDE OF CMU TO BE PAINTED TO MATCH EXISTING BUILDING.

SCALE: 3" = 1'-0"

HM HEAD @ CMU

SCALE: 3" = 1'-0"

HM JAMB @ CMU

SCALE: 3" = 1'-0"

DOOR SILL

SCALE: 3" = 1'-0"

HM HEAD @ EXIST CMU

SCALE: 3" = 1'-0"

HM JAMB @ EXIST CMU

SCALE: 1 1/2" = 1'-0"

TYPICAL CMU CONTROL JOINT DETAIL

DATE INITIAL

08/12/2020 JLF

DOOR 100-1 REMOVED FROM SCHEDULE PER ADDENDUM NO. 2

Sheets
A101 - FLOOR PLAN, ELEVATIONS & BUILDING SECTION
A301 - SCHEDULES, DOOR AND WINDOW DETAILS