This document provides specifications for room identification signage at the Little Bighorn Battlefield National Monument. The specifications cover a variety of sign types including room identification, restroom, occupancy limit, fire riser, elevator, stair access, and fire department connection signs. Sign materials include stainless steel, wood, and vinyl applied with raised letters and Braille. Specifications outline sign dimensions, text styles, fastening methods, and mounting locations compliant with accessibility standards. Production samples, schedules, and sustainable product data are required submittals. The special warranty covers repairs for five years.
View the file
Other files for this federal contract opportunity
Show all 35
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LIBI 241430 10 14 23.16 - 1
ROOM-IDENTIFICATION PANEL SIGNAGE
SECTION 10 14 23.16 - ROOM-IDENTIFICATION PANEL SIGNAGE
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary
Conditions and Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section includes room-identification signs that are directly attached to the building.
B. Related Requirements:
1. Section 10 14 19 "Dimensional Letter Signage" for building signage.
1.3 DEFINITIONS
A. Accessible: In accordance with the accessibility standard.
1.4 COORDINATION
A. Furnish templates for placement of sign-anchorage devices embedded in permanent construction by other installers.
B. Furnish templates for placement of electrical service embedded in permanent construction by other installers.
1.5 ACTION SUBMITTALS
A. Product Data: For each type of product.
B. Sustainable Design Submittals:
1. Product Data: For adhesives, indicating VOC content.
2. Laboratory Test Reports: For adhesives, indicating compliance with requirements for low-emitting materials.
C. Shop Drawings: For room-identification signs.
1. Include fabrication and installation details and attachments to other work.
2. Show sign mounting heights, locations of supplementary supports to be provided by other installers, and accessories.
http://www.arcomnet.com/sustainable_design.aspx?topic=11
LIBI 241430 10 14 23.16 - 2
3. Show message list, typestyles, graphic elements, including raised characters and Braille, and layout for each sign at least half size.
D. Samples for Initial Selection: For each type of sign assembly, exposed component, and exposed finish.
1. Include representative Samples of available typestyles and graphic symbols.
E. Samples for Verification: For each type of sign assembly showing all components and with the required finish(es), in manufacturer's standard size unless otherwise indicated and as follows:
1. Room-Identification Signs: Full-size Sample.
2. Exposed Accessories: Full-size Sample of each accessory type.
3. Full-size Samples, if approved, will be returned to Contractor for use in Project.
F. Product Schedule: For room-identification signs. Use same designations indicated on Drawings or specified.
1.6 INFORMATIONAL SUBMITTALS
A. Qualification Data: For Installer and manufacturer.
B. Sample Warranty: For special warranty.
1.7 CLOSEOUT SUBMITTALS
A. Maintenance Data: For signs to include in maintenance manuals.
1.8 MAINTENANCE MATERIAL SUBMITTALS
A. Furnish extra materials, from the same product run, that match products installed and that are packaged with protective covering for storage and identified with labels describing contents.
1. Tools: One set(s) of specialty tools for assembling signs and replacing variable sign components.
1.9 QUALITY ASSURANCE
A. Installer Qualifications: An entity that employs installers and supervisors who are trained and approved by manufacturer.
1.10 FIELD CONDITIONS
A. Field Measurements: Verify locations of anchorage devices embedded in permanent construction by other installers by field measurements before fabrication, and indicate measurements on Shop
Drawings.
LIBI 241430 10 14 23.16 - 3
1.11 WARRANTY
A. Special Warranty: Manufacturer agrees to repair or replace components of signs that fail in materials or workmanship within specified warranty period.
1. Failures include, but are not limited to, the following:
a. Deterioration of finishes beyond normal weathering.
b. Deterioration of embedded graphic image.
c. Separation or delamination of sheet materials and components.
2. Warranty Period: Five years from date of Substantial Completion.
PART 2 - PRODUCTS
2.1 PERFORMANCE REQUIREMENTS
A. Accessibility Standard: Comply with applicable provisions in the USDOJ's "2010 ADA Standards for Accessible Design" the ABA standards of the Federal agency having jurisdiction and
ICC A117.1.
2.2 ROOM-IDENTIFICATION SIGNS
A. Room-Identification Sign (Sheet A6.4): Sign system with smooth, uniform surfaces; with message and characters having uniform faces, sharp corners, and precisely formed lines and profiles; and as follows:
1. Manufacturers: Subject to compliance with requirements, provide products by the following:
a. 3 Form.
b. Allotech Signs
c. Best Sign Systems, Inc.
d. Graphik Display & Sign
e. Hightech Signs
f. Impact Signs
g. Approved Substitution.
2. Laminated-Sheet Sign: Stainless steel face sheet with raised graphics and braille laminated to ¼” laser cut wood backer sheet to produce composite sheet sign.
a. Composite-Sheet Thickness: As indicated on Drawings.
b. Laser cut graphic images cut in wood as indicated on Signage Types.
c. Surface-Applied Graphics: Raised letters and symbols.
d. Color(s): #4 stainless steel finish over wood to match wood doors veneer and finish, numbers, letters and symbols to be black.
e. Size: As indicated on Drawings.
http://www.specagent.com/Lookup?ulid=12675 http://www.specagent.com/Lookup?uid=123457090136
LIBI 241430 10 14 23.16 - 4
3. Sign-Panel Perimeter: Finish edges smooth.
a. Edge Condition: Square as indicated on Drawings.
b. Corner Condition in Elevation: Square as indicated on Drawings.
4. Mounting:
a. Room Signage: Manufacturer's standard method for surface mounting to wall for size of sign panels.
b. Area Signage: Manufacturer's standard method for ceiling suspension mounting.
5. Text and Typeface: Accessible raised characters and Braille typeface as selected by
Contracting Officer from manufacturer's full range and variable content as scheduled. Finish raised characters to contrast with background color, and finish Braille to match background color.
B. Non-laminated Panel Sign (Sheet A6.4): Sign with smooth, uniform surfaces; with message and characters having uniform faces, sharp corners, and precisely formed lines and profiles;
and as follows:
1. Solid-Sheet Sign: 0.0625 inch Stainless Steel sheet with #4 finish and Applied Graphics"
Subparagraph and as follows:
a. Thickness: Stainless Steel 0.0625 inch with #4 finish.
b. Surface-Applied, Raised Graphics: Applied polymer characters and Braille.
C. Non-laminated Panel Sign (Sheet A6.4): Sign with smooth, uniform surfaces; with message and characters having uniform faces, sharp corners, and precisely formed lines and profiles;
and as follows:
1. Solid-Sheet Sign: ¼” Wood with veneer and finish to match doors and Applied Graphics as follows:
a. Thickness: ¼” Wood.
b. Surface-Applied, Raised Graphics: Applied polymer characters and Braille.
D. Sign Letters for Doors (Sheet A6.4): 1” black vinyl letters on a white reflective background.
2.3 SIGN MATERIALS
A. Metal and Wood Laminate: Stainless Steel and wood decorative laminate complying with
NEMA LD 3 and the following requirements:
1. Faces: .0625 inch stainless steel with #4 finish and 1/4:” wood to match wood doors.
2. Exposed Edges: Finish to match faces.
B. Stainless Steel Sheet: 0.0625 inch with #4 finish.
C. Wood Panel: ¼” wood panel with veneer face and finish to match wood doors.
LIBI 241430 10 14 23.16 - 5
D. Vinyl Film: UV-resistant vinyl film with pressure-sensitive, permanent adhesive; die cut to form characters or images as indicated on Drawings.
2.4 ACCESSORIES
A. Fasteners and Anchors: Manufacturer's standard as required for secure anchorage of signs, noncorrosive and compatible with each material joined, and complying with the following:
1. Use concealed fasteners and anchors unless indicated to be exposed.
2. Sign Mounting Fasteners:
a. Concealed Studs: Concealed (blind), threaded studs welded or brazed to back of sign material or screwed into back of sign assembly unless otherwise indicated.
b. Through Fasteners: Exposed metal fasteners matching sign finish, with type of head indicated, and installed in predrilled holes.
B. Adhesive: As recommended by sign manufacturer.
1. Verify adhesives have a VOC content of 70 g/L or less.
2.5 FABRICATION
A. General: Provide manufacturer's standard sign assemblies according to requirements indicated.
1. Preassemble signs and assemblies in the shop to greatest extent possible. Disassemble signs and assemblies only as necessary for shipping and handling limitations. Clearly mark units for reassembly and installation; apply markings in locations concealed from view after final assembly.
2. Mill joints to a tight, hairline fit. Form assemblies and joints exposed to weather to resist water penetration and retention.
3. Conceal connections if possible; otherwise, locate connections where they are inconspicuous.
4. Provide rabbets, lugs, and tabs necessary to assemble components and to attach to existing work. Drill and tap for required fasteners. Use concealed fasteners where possible; use exposed fasteners that match sign finish.
B. Subsurface-Applied Graphics: Apply graphics to back face of clear face-sheet material to produce precisely formed image. Image shall be free of rough edges.
2.6 GENERAL FINISH REQUIREMENTS
A. Protect mechanical finishes on exposed surfaces from damage by applying a strippable, temporary protective covering before shipping.
http://www.arcomnet.com/sustainable_design.aspx?topic=143
LIBI 241430 10 14 23.16 - 6
B. Appearance of Finished Work: Noticeable variations in same piece are not acceptable. Variations in appearance of adjoining components are acceptable if they are within the range of approved
Samples and are assembled or installed to minimize contrast.
PART 3 - EXECUTION
3.1 INSTALLATION
A. General: Install signs using mounting methods indicated and according to manufacturer's written instructions.
1. Install signs level, plumb, true to line, and at locations and heights indicated, with sign surfaces free of distortion and other defects in appearance.
2. Install signs so they do not protrude or obstruct according to the accessibility standard.
3. Before installation, verify that sign surfaces are clean and free of materials or debris that would impair installation.
B. Accessibility: Install signs in locations on walls as indicated on Drawings and according to the accessibility standard.
C. Mounting Methods:
1. Concealed Studs: Using a template, drill holes in substrate aligning with studs on back of sign. Remove loose debris from hole and substrate surface.
2. Through Fasteners: Drill holes in substrate using predrilled holes in sign as template.
Countersink holes in sign if required. Place sign in position and flush to surface. Install through fasteners and tighten.
3. Adhesive: Clean bond-breaking materials from substrate surface and remove loose debris.
Apply linear beads or spots of adhesive symmetrically to back of sign and of suitable quantity to support weight of sign after cure without slippage. Keep adhesive away from edges to prevent adhesive extrusion as sign is applied and to prevent visibility of cured adhesive at sign edges. Place sign in position, and push to engage adhesive. Temporarily support sign in position until adhesive fully sets.
3.2 ADJUSTING AND CLEANING
A. Remove and replace damaged or deformed signs and signs that do not comply with specified requirements. Replace signs with damaged or deteriorated finishes or components that cannot be successfully repaired by finish touchup or similar minor repair procedures.
B. Remove temporary protective coverings and strippable films as signs are installed.
C. On completion of installation, clean exposed surfaces of signs according to manufacturer's written instructions, and touch up minor nicks and abrasions in finish. Maintain signs in a clean condition during construction and protect from damage until acceptance by Owner.
END OF SECTION 10 14 23.16
0.0625 INCH STAINLESS STEEL
RAISED LETTERS AND
GRADE 2 BRAILLE, BRUSHED
ALUMINUM FINISH
NOTE: BRAILLE SHALL BE
48" MIN. AND 60" MAX
ABOVE THE FINISH FLOOR,
MEASURED TO THE
BASELINE OF BRAILLE
CELLS.
EXIT
5 1/2"
1 1/2"
M
IN
M
IN
1" RAISED LETTERS
ON CENTER
1/4" LASER CUT WOOD
PANEL. WOOD FINISH TO
MATCH WOOD DOOR FINISH.
1/4" LASER CUT WOOD
PANEL. WOOD FINISH TO
MATCH WOOD DOOR FINISH.
RAISED LETTERS
AND GRADE 2
BRAILLE, BRUSHED
ALUMINUM FINISH
1" RAISED LETTERS
ON CENTERRESTROOM
5 1/2"
7/8"7/8"
0.0625 INCH STAINLESS STEEL
NOTE: BRAILLE SHALL BE 48" MIN.
AND 60" MAX ABOVE THE FINISH
FLOOR, MEASURED TO THE
BASELINE OF BRAILLE CELLS.
MAX OCCUPANCY
86 CLOSED
168 COMBINED
1/4" WOOD PANEL SIGN. WOOD FINISH
TO MATCH WOOD DOOR FINISH.
8 5/8"
5/8" RAISED LETTERS
ON CENTER
REFER TO CODE
PLAN FOR
OCCUPANCY OF
THE ROOM
M
IN
M
IN
FIRE RISER
1" VINYL LETTERING
ADHERED TO DOOR
SURFACE, LETTERS TO
BE WITH RED ON A
WHITE REFLECTIVE
BACKGROUND
8"
9"
1' -9
/4
USE INTERCOM FOR
HELP IN
EMERGENCY
HELP EXITING IS
AVAILABLE BY
USING
THE INTERCOM
USE STAIRS AS SOON
AS POSSIBLE UNLESS
ASSISTING OTHERS,
SEE MAP FOR
LOCATIONS
1/ 2"
1/
2" 1/
2" 5/
8"
GRADE 2
BRAILLE
EGRESS MAP4"
1/ 2"
STAINLESS STEEL PLATE
PHOTOPOLYMER
OR SILK SCREEN.
VERIFY W/
ELEVATOR
MANUFACTURER.
BY ELEVATOR MANUFACTURER.
5"
IN CASE OF
FIRE
USE STAIRWAY
DO NOT USE
ELEVATORS
1/ 2"
1/ 2"
STAINLESS STEEL PLATE
W/ SQUARE EDGES,
MECHANICALLY
FASTENED TO THE WALL
W/ CONCEALED
FASTENERS,
COORDINATE TYPE OF
FASTENER WITH
CONTRACTING OFFICER
RAISED LETTERS AND
GRADE 2 BRAILLE, BLACK
FINISH
CALL BUTTONS
V
ER
IF
Y
W
C .O
E
LE
V
A
TO
R M
N F.
1' -6
FLOOR
BY ELEVATOR MANUFACTURER.
M
IN3
3"
STAINLESS STEEL PLATE W/
SQUARE EDGES, MECHANICALLY
FASTENED TO THE WALL W/
CONCEALED FASTENERS,
COORDINATE TYPE OF
FASTENER WITH CONTRACTING
OFFICER
RAISED FLOOR NUMBER,
BLACK FINISH
BY ELEVATOR MANUFACTURER.
M
IN3
3"
STAINLESS STEEL PLATE W/
SQUARE EDGES,
MECHANICALLY FASTENED TO
THE WALL W/ CONCEALED
FASTENERS, COORDINATE
TYPE OF FASTENER WITH
CONTRACTING OFFICER
RAISED IMAGE, BLACK
FINISH
BY ELEVATOR MANUFACTURER.
RAISED LETTERS,
BLACK FINISH
8"
2" ROOM NAME
5/ 8"
3/ 4"
5/ 8"
STAINLESS STEEL PLATE W/ SQUARE
EDGES, MECHANICALLY FASTENED TO
THE WALL W/ CONCEALED FASTENERS,
COORDINATE TYPE OF FASTENER WITH
CONTRACTING OFFICER
1'-0"
1' -8
STAIR 1
EXIT DISCHARGE
THIS LEVEL
NO ROOF ACCESS
LL
1" 5/
8" 1"
1/
2" 5"
2" 1"
3/ 4"
1/
2" 1"
3/ 8"
M
IN
STAINLESS STEEL
PLATE W/ SQUARE
EDGES, MECHANICALLY
FASTENED TO THE
WALL W/ CONCEALED
FASTENERS,
COORDINATE TYPE OF
FASTENER WITH
CONTRACTING OFFICER
RAISED
LETTERS &
NUMBER,
BLACK FINISH
RAISED
LETTERS,
BLACK FINISH
SEE BRAILLE
DETAILS
1'-0"
1' -8
STAIR 1
DOWN TO LEVEL
1 FOR EXIT
DISCHARGE
NO ROOF ACCESS
1" 5/
8" 1"
1/
2" 5"
2" 1"
3/ 4"
1/
2" 1"
3/ 8"
M
IN
STAINLESS STEEL PLATE
W/ SQUARE EDGES,
MECHANICALLY
FASTENED TO THE WALL
W/ CONCEALED
FASTENERS,
COORDINATE TYPE OF
FASTENER WITH
CONTRACTING OFFICER
RAISED LETTERS &
NUMBER, BLACK
FINISH
RAISED
LETTERS,
BLACK FINISH
SEE BRAILLE
DETAILS
1'-0"
1' -8
STAIR 2
EXIT DISCHARGE
THIS LEVEL
ROOF ACCESS
1" 5/
8" 1"
1/
2" 5"
2" 1"
3/ 4"
1/
2" 1"
3/ 8"
M
IN
STAINLESS STEEL PLATE
W/ SQUARE EDGES,
MECHANICALLY
FASTENED TO THE WALL
W/ CONCEALED
FASTENERS,
COORDINATE TYPE OF
FASTENER WITH
CONTRACTING OFFICER
RAISED LETTERS &
NUMBER, BLACK
FINISH
RAISED
LETTERS,
BLACK FINISH
SEE BRAILLE
DETAILS
1'-0"
1' -8
STAIR 2
DOWN TO LEVEL
1 FOR EXIT
DISCHARGE
ROOF ACCESS
1" 5/
8" 1"
1/
2" 5"
2" 1"
3/ 4"
1/
2" 1"
3/ 8"
M
IN
STAINLESS STEEL PLATE
W/ SQUARE EDGES,
MECHANICALLY
FASTENED TO THE WALL
W/ CONCEALED
FASTENERS,
COORDINATE TYPE OF
FASTENER WITH
CONTRACTING OFFICER
RAISED
LETTERS,
BLACK FINISH
RAISED LETTERS &
NUMBER, BLACK
FINISH
SEE BRAILLE
DETAILS
1'-6"
SIGNAGE MECHANICALLY
FASTENED TO WALL
WITH EXPOSED
FASTENERS.
RAISED RED
LETTERING
ALUMINUM SIGN
MATERIAL - WHITE
BACKGROUND
FIRE
DEPARTMENT
CONNECTION1
1'-6"
SIGNAGE MECHANICALLY
FASTENED TO WALL WITH
EXPOSED FASTENERS.
RAISED RED
LETTERING
ALUMINUM SIGN
MATERIAL - WHITE
BACKGROUND
XXX PSI
OPERATING
PRESSURE
SIGNAGE TYPE F2
EXTERIOR
GRADE
SIGNAGE TYPE F1
EXTERIOR
GRADE
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.A/E FIRM TITLE OF DRAWING
OF
PMIS/PKG NO.
SHEET
DRAWING NO.
179600
241430
LITTLE BIGHORN BATTLEFIELD NATIONAL MONUMENT
ajc ajc
A6.4
SIGNAGE TYPE
ajc
SEPT. 21, 2023
AJC ARCHITECTS
SALT LAKE CITY,
UT 84104
189 254
SCALEA6.4 6" = 1'-0"
A1 SIGN - EXIT A1
SCALEA6.4 6" = 1'-0"
A2 SIGN - RESTROOM A2
SCALEA6.4 6" = 1'-0"
A3 SIGN - OCCUPANCY A3
SCALEA6.4 3" = 1'-0"
FR SIGN - FIRE RISER FR
SCALEA6.4 3" = 1'-0"
V1 ELEVATOR SIGNAGE - TYPE V1
SCALEA6.4 3" = 1'-0"
V2 ELEVATORS SIGNAGE - TYPE V2
SCALEA6.4 3" = 1'-0"
V3 ELEVATOR SIGNAGE - TYPE V3
SCALEA6.4 3" = 1'-0"
F3 ELEVATOR SIGNAGE - TYPE F3
SCALEA6.4 3" = 1'-0"
R1 INTERIOR GRADE SIGNAGE - TYPE R1
SCALEA6.4 3" = 1'-0"
S1 STAIR ACCESS SIGNAGE - TYPE S1
SCALEA6.4 3" = 1'-0"
S2 STAIR ACCESS SIGNAGE - TYPE S2
SCALEA6.4 3" = 1'-0"
S3 STAIR ACCESS SIGNAGE - TYPE S3
SCALEA6.4 3" = 1'-0"
S4 STAIR ACCESS SIGNAGE - TYPE S4
SCALEA6.4 3" = 1'-0"
FDC FIRE DEPARTMENT CONNECTION SIGNAGE - FDC
MARK DATE DESCRIPTION
3 11/13/2023 ADDENDUM