This document is a federal construction project specification for resilient flooring installation at Fort Vancouver National Historic Site. The specification covers requirements for several types of resilient flooring materials including linoleum tile, static control tile, stair treads and risers, and rubber base. It provides product data submittal requirements, quality standards, testing and certification details, delivery and storage procedures, field conditions, and installation instructions. The related federal contract opportunity is for rehabilitation of the Main Parade Ground Barracks and Crossroads Parking Lot at Fort Vancouver National Historic Site in Vancouver, Washington, to be conducted by the Department of the Interior National Park Service National Office.
View the file
Other files
Show all 34
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FOVA 241806 09 65 00 - 1
RESILIENT FLOORING
SECTION 09 65 00 - RESILIENT FLOORING
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary
Conditions and Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section includes:
1. Resilient sheet flooring.
2. Static control resilient sheet flooring.
3. Static control resilient tile flooring
4. Resilient base.
5. Resilient stair accessories.
6. Installation accessories.
1.3 REFERENCE STANDARDS:
A. ASTM F150 – Standard Test Method for Electrical Resistance of Conductive and Static
Dissipative Resilient Flooring; 2006 (Reapproved 2013).
B. ASTM F710 – Standard Practice for Preparing Concrete Floors to Receive Resilient Flooring;
2017.
C. ASTM F1861 – Standard Specification for Resilient Wall Base; 2016.
D. ASTM F2034 – Standard Specification for Sheet Linoleum Floor Covering; 2008 (Reapproved
2013).
E. ASTM F2169 – Standard Specification for Resilient Stair Treads; 2015, with Editorial Revision
(2016).
1.4 ACTION SUBMITTALS
A. Product Data: Provide data on specified products, describing physical and performance characteristics; including sizes, patterns, and colors available; and installation instructions.
B. Sustainability Submittals: Submit VOC content documentation for flooring and adhesives.
C. Shop Drawings: Indicate seaming plans and floor patterns.
D. Samples for Verification: Submit two samples, 6 by 6 inches in size minimum, illustrating color and pattern for each resilient flooring product specified.
FOVA 241806 09 65 00 - 2
E. Concrete Testing Standard: Submit a copy of ASTM F710.
F. Concrete Sub-floor test report: Submit a copy of the moisture and alkalinity (pH) test reports.
G. Certification: Prior to installation of flooring, submit written certification by flooring manufacturer and adhesive manufacturer that condition of sub-floor is acceptable.
1.5 CLOSEOUT SUBMITTALS
A. Maintenance Data: Include maintenance procedures, recommended maintenance materials, and suggested schedule for cleaning, stripping, and re-waxing.
1.6 MAINTENANCE MATERIAL SUBMITTALS
A. Furnish extra materials that match products installed and that are packaged with protective covering for storage and identified with labels describing contents.
1. Extra Sheet Flooring: Furnish not less than 10 linear feet or fraction thereof, in roll form and in full roll width for each type, color, and pattern of sheet flooring installed.
2. Extra Wall Base: Furnish not less than 20 linear feet.
3. Extra Stair Materials: Quantity equivalent to 5 percent of each type and color.
1.7 QUALITY ASSURANCE
A. Manufacturer Qualifications: Company specializing in manufacturing specified flooring with minimum three years documented experience.
B. Installer Qualifications: Company specializing in installing specified flooring with minimum three years documented experience.
C. Testing Agency Qualifications: Independent firm specializing in performing concrete slab moisture testing and inspections of the type specified in this section
D. Comply with Architectural Barriers Act Accessibility Standards (ABAAS) and DSC
Accessibility Requirements.
1.8 DELIVERY, STORAGE, AND HANDLING
A. Upon receipt, immediately remove any shrink-wrap and check materials for damage and the correct style, color, quantity and run numbers.
B. Store all materials off of the floor in an acclimatized, weather-tight space.
C. Maintain temperature in storage area between 55 degrees F and 90 degrees F.
D. Protect roll materials from damage by storing on end.
FOVA 241806 09 65 00 - 3
E. Do not double stack pallets.
1.9 FIELD CONDITIONS
A. Store materials for not less than 48 hours prior to installation in area of installation at a temperature of 70 degrees F to achieve temperature stability. Thereafter, maintain conditions above 55 degrees F.
PART 2 - PRODUCTS
2.1 TILE FLOORING
A. Linoleum Tile Flooring (Type RES-1): Homogeneous wear layer bonded to backing, with color and pattern through wear layer thickness.
1. Manufacturers:
a. Forbo Flooring, Inc; Marmoleum real: www.forboflooring.com
2. Minimum Requirements: Comply with ASTM F2195, Type I.
3. Backing: Jute backing.
4. Tile Size: 13.11” x 13.11”
5. Thickness: 0.08 inch, minimum, excluding backing.
6. Seams: Heat welded.
7. Pattern: Marbleized.
8. Color: 3141 Himalaya
2.2 STATIC CONTROL TILE FLOORING
A. Static Control Tile (Type ESD): Homogeneous; color and pattern throughout thickness.
1. Manufacturers:
a. Forbo Flooring, Inc; Colorex ec plus: www.forboflooring.com
2. Minimum Requirements: Solid vinyl tile complying with ASTM F1700, Class 1, Type A
3. Electrical Resistance:
a. Conductive Tile: Resistance between 25 kiloohms and 1.0 megohms as tested in accordance with ASTM F150.
b. Dissipative Tile: Resistance between 1.0 megohms and 1000 megohms as tested in accordance with ASTM F150.
4. Tile size: 24 by 24 inch.
5. Total thickness: 0.41 inch
6. Color: 621013 sahara
2.3 STAIR COVERING
A. Stair Treads: Rubber; full width and depth of stair tread in one piece; tapered thickness.
1. Manufacturers:
a. Burke Flooring; Endura Stair Treads: www.burkeflooring.com
b. Johnsonite, a Tarkett Compnay: www.johnsonite.com
c. Roppe Corp: www.roppe.com
FOVA 241806 09 65 00 - 4
2. Minimum Requirements: Comply with ASTM F2169, Type TV, vinyl, thermoplastic.
3. Nominal Thickness: 1/4 inch (6 mm) and tapered to back edge.
4. Nosing: Square.
5. Nosing Height: 1-1/2 inches.
6. Class: 2 (pattern: embossed, grooved, or ribbed)
7. Group: 2 (with contrasting color for the visually impaired).
8. Size: Lengths and depths to fit each stair tread in one piece.
9. Integral risers: Smooth, flat; in height that fully covers substrates.
B. Separate Risers: Smooth, flat; in height that fully covers substrate; produced by same manufacturer as treads and recommended by manufacturer for installation with treads.
1. Style: Toeless, by length matching treads.
2. Thickness: Manufacturer’s standard.
C. Landing Tile: Matching treads; produced by same manufacturer as treads and recommended by manufacturer for installation with treads.
D. Colors and Patterns: As selected by Contracting Officer from manufacturer’s full range.
2.4 RESILIENT BASE
A. Resilient Base (Type RB): ASTM F1861, Type TP, rubber, thermoplastic; top set Style B, Cove.
1. Manufacturers:
a. Forbo Flooring, Inc: www.forboflooring.com
2. Height: 4 inch.
3. Thickness: 0.125 inch.
4. Length: Roll.
5. Color: As selected by Contracting Officer from manufactuer’s full range to match ESD.
2.5 INSTALLATION MATERIALS
A. Subfloor filler: White premix latex; type recommended by adhesive material manufacturer.
B. Primers, Adhesives, and Seam Sealer: Waterproof; types recommended by flooring manufacturer.
C. Moldings, Transitions, and Edge Strips: Same material as flooring.
D. Copper Grounding Strips: Type and size as recommended by static control flooring manufacturer.
E. Sealer and Wax: Types recommended by flooring manufacturer.
FOVA 241806 09 65 00 - 5
PART 3 - EXECUTION
3.1 EXAMINATION
A. Verify that surfaces are flat to tolerances acceptable to flooring manufacturer, free of cracks that might telegraph through flooring, clean, dry, and free of curing compounds, surface hardeners, and other chemicals that might interfere with bonding of flooring to substrate.
B. Verify that wall surfaces are smooth and flat within the tolerances specified for that type of work, are dust-free, and are ready to receive resilient base.
C. Cementitious Sub-floor Surfaces: Verify that substrates are dry enough and ready for resilient flooring installation by testing for moisture and pH.
1. Test in accordance with ASTM F710.
2. Obtain instructions if test results are not within limits recommended by resilient flooring manufacturer and adhesive materials manufacturer.
3.2 PREPARATION
A. Prepare floor substrates as recommended by flooring and adhesive manufacturers.
B. Remove sub-floor ridges and bumps. Fill minor low spots, cracks, joints, holes, and other defects with sub-floor filler to achieve smooth, flat, hard surfaceFill cracks, holes, and depressions in substrates with trowelable leveling and patching compound; remove bumps and ridges to produce a uniform and smooth substrate.
C. Prohibit traffic until filler is fully cured.
D. Immediately before installation, sweep and vacuum clean substrates to be covered by flooring.
3.3 INSTALLATION - GENERAL
A. Starting installation constitutes acceptance of sub-floor conditions.
B. Install in accordance with manufacturer's written instructions.
C. Spread only enough adhesive to permit installation of materials before initial set.
D. Place copper grounding strip in conductive adhesive and apply additional adhesive to top side of strip before installing static control flooring. Allow strip to extend beyond flooring in accordance with static control flooring manufacturer's instructions. Refer to Section 26 05 26 for grounding and bonding to building grounding system.
E. Fit joints and butt seams tightly.
F. Set flooring in place, press with heavy roller to attain full adhesion.
G. Where type of floor finish, pattern, or color are different on opposite sides of door, terminate flooring under centerline of door.
FOVA 241806 09 65 00 - 6
H. Install edge strips at unprotected or exposed edges, where flooring terminates, and where indicated.
1. Resilient Strips: Attach to substrate using adhesive.
3.4 INSTALLATION – SHEET FLOORING
A. Unroll linoleum sheet flooring and allow it to stabilize before cutting and fitting.
B. Lay out linoleum sheet flooring as follows:
1. Maintain uniformity of flooring direction.
2. Minimize number of seams; place seams in inconspicuous and low-traffic areas, at least 6 inches (152 mm) away from parallel joints in flooring substrates.
3. Match edges of flooring for color shading at seams.
4. Avoid cross seams.
5. Eliminate deformations that result from hanging method used during drying process
(stove bar marks).
C. Integral-Flash-Cove Base as indicated on Drawings: Cove flooring 4 inches up vertical surfaces. Support flooring at horizontal and vertical junction with cove strip. Butt at top against cap strip.
3.5 INSTALLATION – TILE FLOORING
A. Mix tile from container to ensure shade variations are consistent when tile is placed, unless otherwise indicated in manufacturer's installation instructions.
B. Lay flooring with joints and seams parallel to building lines to produce symmetrical pattern.
3.6 INSTALLATION – RESILIENT BASE
A. Fit joints tightly and make vertical. Maintain minimum dimension of 18 inches between joints.
B. Miter internal corners. At external corners, use premolded units. At exposed ends, use premolded units.
C. Install base on solid backing. Bond tightly to wall and floor surfaces.
D. Scribe and fit to door frames and other interruptions.
3.7 INSTALLATION – STAIR COVERINGS
A. Install stair coverings in one piece for full width and depth of tread.
B. Install stringers configured tightly to stair profile.
C. Adhere over entire surface. Fit accurately and securely.
FOVA 241806 09 65 00 - 7
3.8 CLEANING AND PROTECTION
A. Remove excess adhesive from floor, base, and wall surfaces without damage.
B. Clean in accordance with manufacturer's written instructions
C. Prohibit traffic on resilient flooring for 48 hours after installation.
3.9 INSPECTION
A. Inspect finished installation to establish compliance with ABAAS and DSC requirements. Use
DSC - CQC Accessibility Inspection Report as basis for recordation. Submit Report to CO for review and final approval. Record observations and supplement with sketches, descriptive data and notes, drawings, measurements, digital images, etc. Coordinate inspections with construction schedule and commence inspection immediately after work is completed. Submit
Report to CO no more than one day (24 hours) after performing inspection.
END OF SECTION 096500
FOVA 241806 09 65 00 - 8
File details come from the government source that posted it. Updated .