SUMMARY REPORT: BULK ASBESTOS, LEAD-BASED
PAINT AND HAZARDOUS MATERIALS SURVEY
NATIONAL PARK SERVICE
OLD SANTA FE TRAIL BUILDING
1100 OLD SANTA FE TRAIL
SANTA FE, NEW MEXICO 87505
PREPARED FOR:
WISS, JANNEY, ELSTNER ASSOCIATES
2000 POWELL STREET, SUITE 1650
EMERYVILLE, CA 94608
PREPARED BY:
SCA
ENVIRONMENTAL, INC.
1 LAKESIDE DRIVE, SUITE 215
OAKLAND, CA 94612
TEL: (510) 645-6200
eFAX: (415) 962-0736
SCA PROJECT NO.: B-12033
MAY 23, 2016
REVISED JUNE 7, 2016
SUMMARY REPORT
BULK ASBESTOS, LEAD-BASED PAINT & HAZARDOUS MATERIALS SURVEY
NATIONAL PARK SERVICE
OLD SANTA FE TRAIL BUILDING
110 OLD SANTA FE TRAIL
SANTA FE, NEW MEXICO 87505
CONDUCTED FOR
MS. UNA GILMARTIN
WISS, JANNEY, ELSTNER ASSOCIATES
2000 POWELL STREET, SUITE 1650
EMERYVILLE, CA 94608
MAY 23, 2016
REVISED JUNE 7, 2016
SCA PROJECT NO. B-12033
PREPARED BY:
GLENN R. CASS, CIH, PE, CAC #92-0092
VICE PRESIDENT
SCA ENVIRONMENTAL, INC.
1 LAKESIDE DRIVE, SUITE 215
OAKLAND, CA 94612
TEL: (510) 645-6200
eFAX: (415) 962-0736
Summary Report for Asbestos and Lead Paint Survey Old Santa Fe Trail Building, 110 Old Santa Fe Trail, Santa Fe, NM SCA Project No.: B-12033 Page i
Table of Contents
1.0 Executive Summary
2.0 Introduction
3.0 Methodology
3.1 Asbestos Containing Materials
3.2 Lead-Based Paints
4.0 Applicable Standards
4.1 Asbestos-Containing Materials
4.2 Lead-Based Paints
5.0 Results and Conclusions
5.1 Asbestos
5.2 Non-Asbestos Materials (non-ACM)
5.3 Lead-Based Paints
5.4 Other Hazards
6.0 Limitations and Exclusions
Attachments
1. Laboratory Results – Asbestos
2. Representative Lead-Based Paint XRF Sampling Results
3. Field Data Sheets
4. Sampling Location Drawings
5. Preliminary Abatement Specifications
SCA Project No.: B-12033 Page ii
List of Common Acronyms and Abbreviations
AAA = Assumed Asbestos-Containing Materials ACM = Asbestos-Containing Materials AHERA = Asbestos Hazard Emergency Response Act AQB = the New Mexico Environmental Department’s Air Quality Bureau.
BK = black paints BL = blue paints BR = brown paints CAC = Certified Asbestos Consultant CAULK = window and door perimeter caulking CERCLA = Comprehensive Environmental Response, Compensation, and Liability Act CFR = Code of Federal Regulations CHMM = Certified Hazardous Materials Manager CIH = Certified Industrial Hygienist CPSC = Consumer Product Safety Commission CR = cream-colored paints CSST = Certified Site Surveillance Technician DS/PLM = Polarized Light Microscopy with Dispersion Staining EPA = the U.S. Environmental Protection Agency EPRI = Electric Power Research Institute EXPJNT = expansion joint FIFRA = Federal Insecticide, Fungicide, and Rodenticide Act FLVCS = linoleum flooring FLVCT = vinyl composite floor tiles ft
= square feet
GN = green paints GROUT = ceramic tile and concrete grouts GY = gray paints HUD = the U.S. Department of Housing and Urban Development LBP = Lead-Based Paints LF = linear feet µg/cm
= micrograms per centimeter squared µg/g = microgram per gram or equivalent to parts per million µg/m
= micrograms per cubic meter µm = microns mg/cm
= milligrams per squared centimeter mg/kg = milligrams per kilogram MR = maroon paints OL = olive paints OR = orange paints OSHA = the federal Occupational Safety and Health Administration OW = off white paints PCB = Polychlorinated Biphenyl PEL = Permissible Exposure Level Penta = Pentachlorophenol
SCA Project No.: B-12033 Page iii
List of Common Acronyms and Abbreviations Cont.
PISTM = steam thermal system pipe insulation PK = pink paints ppm = parts per million PUTTY = window pane putty QA/QC = Quality Assurance/Quality Control RCRA = Resource Conservation Recovery Act RCW = Regulated Controlled Waste RD = red paints REA = Registered Environmental Assessor RFAG = built-up tar and gravel roofing RFPTCH = roof patching compounds RFROLL = rolled roofing RWQCB = the Regional Water Quality Control Board SF = square feet TN = tan paints TSI = Thermal System Insulation WAC = Washington Administrative Code WH = white paints WLCER = ceramic wall tiles WLPL = wall plaster YW = yellow paints
SCA Project No.: B-12033 Page 1
1.0 Executive Summary
SCA Environmental, Inc. (SCA) conducted a partial pre-renovation hazardous materials survey for lead-based paints, asbestos-containing construction materials, and associated environmental hazards at the Old Santa Fe Trail Building at 110 Old Santa Fe Trail in Santa Fe, CA (hereafter referred to as "the Building") on May 11, 2016.
Prior to any renovations or demolition, the National Emission Standard for Hazardous Air Pollutants (NESHAP) mandated by the Environmental Protection Agency (EPA) require that buildings be inspected for asbestos-containing materials (ACM) and materials subject to damage or which will be made friable, be removed.
Sampling by SCA in May, 2016 and Anderson Halls Architects in October 2011 found the following ACM:
Mudded elbows on the heating hot water and domestic hot water system sampled in the Basement Stairs and
Basement Storage Room and considered typical of the non-abated segments and concealed risers and branches throughout the building [SCA Sample I.D. OSFT-TSI-107-1 & 2 with 10% Chrysotile].
White interior plasters over gray base plasters with horse hair sampled in Annex Building Room A5 western perimeter façade [SCA Sample I.D. OSFT-WLPL-104-10 with 2% Chrysotile in the brown base layer] [Note the interior plasters throughout the Annex Building shall be treated as asbestos-containing].
White interior plasters over gray base plasters with horse hair sampled in Annex Building Shop A5 southern perimeter façade [SCA Sample I.D. OSFT-WLPL-104-11 with 2% Chrysotile in the brown base layer]
[Note the interior plasters throughout the Annex Building shall be treated as asbestos-containing].
Note that the thermal system insulation was abated during the boiler replacement project within the past 3 to 4 years.
However, mudded elbows and remnants of the original system are still visible in the Crawl Space Tunnels and the Basement Records and Storage Rooms as well as at concealed risers and branches on both the heating hot water system and the domestic hot water system. The extent of required abatement for the seismic renovations is unknown but could impact segments of these systems if plaster removal is required indoors.
Interior plasters throughout the Annex Building shall be treated as ACM based on the serial analyses completed for these samples.
Suspect materials that were not sampled but should be assumed to be asbestos-containing include the following:
Suspect older vinyl floor tiles and associated mastics under carpeting in various locations [SCA Sample I.D.
OSFT-FLVCT-AAA, assumed ACM].
Destructive testing may be warranted for the above suspect ACM following vacancy of the building or area to ascertain the validity of the assumptions.
“Trace” asbestos-containing materials (>0.1% and <1% asbestos by weight) sampled by SCA include:
Pink white stucco skimcoat over gray base coat and non-ACM building paper sampled on the 1 st Floor west facade [AHA Sample I.D. #1 W1 with <1% Chrysotile in the skimcoat and base stucco plasters].
Pink white stucco skimcoat over brown/gray base coat over reddish/gray stuccos with white fibrous debris sampled on the 1 st Floor south facade [AHA Sample I.D. #4 S1 with <1% Chrysotile in all layers].
Pink multi-colored stucco plaster over non-ACM building paper over pink/gray and red/gray older stucco plasters sampled on the 2 nd
Floor west facade [AHA Sample I.D. #5 W2 with <1% Chrysotile in the pink multi-colored layer].
Multi-layered exterior stucco plasters sampled at SW Annex corner with sandy tea-colored layer over older
SCA Project No.: B-12033 Page 2 orange-yellow layer [SCA Sample I.D. OSFT-STUCCO-101-1 with <1% Chrysotile in the brown layer]
[Note that a 1,000 point count of this sample found <0.1% Chrysotile].
Despite a large number of samples showing no detectable asbestos in the multi-layered exterior stucco plasters, sampling in 2011 and 2016 found ‘trace’ Chrysotile in various layers. Because the removal of this material generally requires sawing into workable segments and pulverizing the materials, airborne asbestos releases are likely to occur during these operations and SCA deems that the material must be removed under full isolation procedures in compliance with 29 CFR 1926.1101 Work Class 2 procedures. The 1,000 point count of the stucco found the asbestos content at <0.1% Chrysotile, so the materials generally can be disposed as non-hazardous waste.
Non-asbestos materials sampled and documented by SCA include:
Pink white stucco skimcoat over pink base coat sampled on the 1
Floor east facade [AHA Sample I.D. #2
E1].
Brown/gray stucco plasters sampled on the 1 st Floor north facade [AHA Sample I.D. #3 N1].
Multi-layered exterior stucco plasters with thin elastomeric layer over gray base over lighter gray base at
Annex Greenhouse southern curb [SCA Sample I.D. OSFT-STUCCO-101-1].
Multi-layered exterior stucco plasters with tea-colored layer over gray base layer over lighter gray layer sampled at south Annex façade outside Room A3 [SCA Sample I.D. OSFT-STUCCO-101-3].
Multi-layered exterior stucco plasters with tea-colored layer over gray base layer over lighter gray layer sampled at south Annex façade’s window outside Room A4 [SCA Sample I.D. OSFT-STUCCO-101-4].
Multi-layered exterior stucco plasters with tea-colored layer over gray base layer over lighter gray layer sampled at South Main Building façade outside Room 128 [SCA Sample I.D. OSFT-STUCCO-101-5].
Multi-layered exterior stucco plasters with tea-colored layer over gray base layer over lighter gray layer sampled at west Main Building façade outside Rm. 124 [SCA Sample I.D. OSFT-STUCCO-101-6].
Multi-layered exterior stucco plasters with tea-colored layer over gray base layer over lighter gray layer sampled at south Main Building façade at the bike racks outside Rm. 116 [SCA Sample I.D. OSFT-
STUCCO-101-7].
Multi-layered exterior stucco plasters with tea-colored layer over gray base layer over lighter gray layer sampled at west Main Building Entry Courtyard wall [SCA Sample I.D. OSFT-STUCCO-101-8].
Multi-layered exterior stucco plasters with tea-colored layer over gray base layer over lighter gray layer sampled at north Main Building outside Rm. 115B [SCA Sample I.D. OSFT-STUCCO-101-9].
Multi-layered exterior stucco plasters with tea-colored layer over gray base layer over lighter gray layer sampled at north Main Building façade outside Rm. 112 [SCA Sample I.D. OSFT-STUCCO-101-10].
Multi-layered exterior stucco plasters with tea-colored layer over gray base layer over lighter gray layer sampled at north Main Building façade at Entry [SCA Sample I.D. OSFT-STUCCO-101-11].
Multi-layered exterior stucco plasters with tea-colored layer over gray base layer over lighter gray layer sampled at north patio outside Conference Rm. 108 with white paints [SCA Sample I.D. OSFT-STUCCO-
101-12].
Multi-layered exterior stucco plasters with newer tea-colored over older tea-colored layer over gray base layer over lighter gray layer sampled at eastern Main Building façade outside Rm. 127 [SCA Sample I.D.
SCA Project No.: B-12033 Page 3
OSFT-STUCCO-101-13].
Multi-layered exterior stucco plasters with newer tea-colored over older tea-colored layer over gray base layer over lighter gray layer sampled at eastern Main Building façade outside 2 nd
Floor Office 207 [SCA
Sample I.D. OSFT-STUCCO-101-14].
Multi-layered exterior stucco plasters with newer tea-colored over older tea-colored layer over gray base layer over lighter gray layer typical for replacement parapet caps throughout [SCA Sample I.D. OSFT-
STUCCO-101-15].
Multi-layered exterior stucco plasters with tea-colored layer over gray base layer over lighter gray layer sampled at western Main Building façade outside 2 nd
Floor Rm. 204 [SCA Sample I.D. OSFT-STUCCO-
101-16].
Multi-layered exterior stucco plasters with tea-colored layer over gray base layer over lighter gray layer sampled at western Main Courtyard with white paints and typical of Main Courtyard throughout [SCA
Sample I.D. OSFT-STUCCO-101-17].
Taupe-colored exterior stucco plasters over gray stucco sampled from interior of the Annex Mail Room
[SCA Sample I.D. OSFT-STUCCO-101-18].
Built-up tar and gravel roof replaced about 10 years ago over insulation layer over decking, typical of roofing throughout [SCA Sample I.D. OSFT-RFAG-102-1] [Note that PVC roofing overlays the built-up roofing for the 2 nd
Floor Main Building].
Red, yellow and brown caulking at perimeter windows sampled at exterior of 2 nd
Floor Rooms 204 & 206 and considered typical throughout [SCA Sample I.D. OSFT-CAULK-103-1 & 2].
Yellow and brown perimeter window caulking sampled at exterior of 2 nd
Floor Room 203 and considered typical throughout [SCA Sample I.D. OSFT-CAULK-103-3].
Yellow and gray caulking at cracked stucco plaster sampled at parapets and considered typical throughout
[SCA Sample I.D. OSFT-CAULK-103-4].
White interior plasters over gray base plasters sampled in Great Room 132 western perimeter façade [SCA
Sample I.D. OSFT-WLPL-104-1].
White interior plasters over gray base plasters sampled in Great Room 132 eastern perimeter façade [SCA
Sample I.D. OSFT-WLPL-104-2].
White interior plasters over gray base plasters sampled in Conference Rm. 108 eastern perimeter façade
[SCA Sample I.D. OSFT-WLPL-104-3].
White interior plasters over gray base plasters with horse hair sampled in Electrical Room off Stairway eastern perimeter façade [SCA Sample I.D. OSFT-WLPL-104-4].
White interior plasters over gray base plasters with horse hair sampled in Electrical Room off Stairway northern perimeter façade [SCA Sample I.D. OSFT-WLPL-104-5].
White interior plasters over gray base plasters with horse hair sampled in 2 nd
Floor Copy Room western perimeter facade [SCA Sample I.D. OSFT-WLPL-104-6].
White interior plasters over gray base plasters with horse hair sampled in the 2 nd
Floor Hallway eastern
SCA Project No.: B-12033 Page 4 perimeter facade [SCA Sample I.D. OSFT-WLPL-104-7].
White interior plasters over gray base plasters with horse hair sampled in 1 st Floor Room 123 western perimeter facade [SCA Sample I.D. OSFT-WLPL-104-8].
White interior plasters over gray base plasters with horse hair sampled in the Basement Boiler Room eastern perimeter façade [SCA Sample I.D. OSFT-WLPL-104-9].
Gray mortars at stone facades sampled in the 1 st Floor Electrical Room, Basement Electrical Closet and
Basement Boiler Room and considered typical throughout [SCA Sample I.D. OSFT-MORTAR-105-1 thru
3].
Brown expansion joint at the Main Courtyard concrete ramp to the Toilets [SCA Sample I.D. EXPJT-106-
1].
12-inch square beige splotched patterned vinyl composite floor tiles with yellow mastics over concrete sampled in the Basement Records Room and typical of the 1 st Floor Copy Room [SCA Sample I.D. OSFT-
FLVCT-108-1].
2-ft. by 4-ft. laid-in ceiling tiles with pinhole and crowfoot pattern sampled in the Basement Records Room
[SCA Sample I.D. OSFT-CLLI-109-1].
New sheetrock wallboard in the Basement Records Room [SCA Sample I.D. OSFT-WLSH-NNN].
New sheetrock wallboard in the Annex Building Mail Room A1 [SCA Sample I.D. OSFT-WLSH-NNN].
New 12-inch square off-white vinyl composite floor tiles and associated mastics in the Annex Building Mail
Room A1 [SCA Sample I.D. OSFT-FLVCT-NNN].
New 12-inch square beige splotched patterned vinyl composite floor tiles and associated mastics in the 1
Floor Vending Room [SCA Sample I.D. OSFT-FLVCT-NNN].
5-inch high various colored vinyl baseboards and associated white mastics over plaster and sheetrock substrates throughout [SCA Sample I.D. OSFT-BBMAS-NNN].
Lead-based paints (LBP), as defined by U.S. Department of Housing and Urban Development (HUD), were identified in the building, including but not necessarily limited to the following:
Off-white paints on the stucco exterior Courtyard façade outside Room 131 [SCA Sample I.D. OW-07-3 with 1.20 mg/cm
Rust-colored paints on the Main Courtyard stucco façade at Room 123 [SCA Sample I.D. RU-09-3 with 2.4 mg/cm
Rust-colored paints on the Main Courtyard exterior stucco façade at Room 115 [SCA Sample I.D. RU-09-4 with 1.80 mg/cm
Pink ceramic tile glazing in the Main Building’s Men’s Toilet [SCA Sample I.D. PK-14-1 with 6.80 mg/cm
Off-white paints on the entry wall plasters in Great Room 132 [SCA Sample I.D. OW-24-1 with 3.30 mg/cm
SCA Project No.: B-12033 Page 5
Various colored ceramic wall tile glazing in the Men’s & Women’s Toilets throughout.
All other tested paints and ceramic tile glazing have a lead content below the HUD definition for LBPs. All site paints shall be treated as having a lead content greater than 600 ppm requiring demolition dust controls and personal protective procedures in compliance with OSHA’s Construction Lead Standard, 29 CFR 1926.62.
In general, any interior and exterior paints found to be peeling and chipping will require stabilization or scraping prior to the proposed renovations or demolition. All intact painted substrates may be removed and disposed of as non-hazardous waste.
SCA Project No.: B-12033 Page 6
2.0 Introduction
This report summarizes the results of the partial pre-renovation hazardous materials survey conducted for the Old Santa Fe Trail Building at 110 Old Santa Fe Trail in Santa Fe, NM (hereafter referred to as "the Building") on May 11, 2016. The purpose of the survey was to determine the presence of regulated and/or potentially hazardous building materials in the building, which is slated for waterproofing repairs and seismic upgrades. Materials addressed in the survey include:
Asbestos-containing materials (ACM);
Lead-based paints (LBP);
Rodent fecal matter; and
Other environmental hazards as noted.
Individuals involved in the survey, and their technical certifications, include:
SCA Staff Role Certifications
Glenn R. Cass, PE, CIH, CAC
Sr. Project Consultant
Professional (Mechanical) Engineer (PE #M18976), since 1978.
Certified Industrial Hygienist (CIH #A4847).
Cal/OSHA Certified Asbestos Consultant (CAC #92-0092).
California Dept. of Public Health Certified Lead Inspector/Assessor, Project Designer & Project Monitor (CDPH #I/D/M-717).
OSHA 40-hr. HAZWOPER Training per 29 CFR 1910.120(e).
The contract laboratory that provided analytical services for the project was:
Laboratory Analysis Type Accreditation
EMSL Analytical, Inc.
San Leandro, CA
Bulk Asbestos Analysis by Polarized Light Microscopy (PLM)
National Voluntary Laboratory Accreditation Program (NVLAP # 101048-3).
California Environmental Laboratory Accreditation Program (ELAP #1620).
SCA Project No.: B-12033 Page 7
3.0 Methodology
3.1 Asbestos Containing Materials
Asbestos sampling was performed in a fashion designed to minimize exposure of the surveyor or others to airborne asbestos fibers. Samples were typically removed from the substrate utilizing a knife or hollow drill bit bored through a wet sponge; the sample material was then placed into an airtight plastic vial. The vial's exterior was decontaminated with a wet sponge, and a unique sample I.D. written on the vial. The vial was then stored in a plastic bag. Sample substrates were patched with a high-temperature caulking compound, where required.
Samples of suspect materials were collected using triplicate sampling procedures. Under these procedures, the first sample is analyzed. If it tests positive for asbestos (>1%), the analysis is suspended for further samples of that material. If the first sample tests only trace positive (between 0.1 to 1%), or negative, then the second and third samples are analyzed sequentially, in order to determine the possible presence of asbestos. If all three samples test negative, the material is considered as non-asbestos. If one or more samples test "trace" positive (<1%), the material is considered to be trace positive. If one or more samples are positive for asbestos, the material is considered positive.
Certain materials, such as plasters and gypboard or sheetrock systems, are frequently non-homogeneous in content.
For such materials, multiple samples were gathered at various points in the building, with all samples analyzed to determine the possible presence of asbestos.
All asbestos samples collected were submitted to EMSL for analysis by polarized light microscopy with dispersion staining (DS/PLM). The Federal Environmental Protection Agency's (EPA) regulations specify the DS/PLM method.
3.2 Lead-Based Paints
Paint samples from typical interior and exterior surfaces were analyzed in-situ to identify the presence and extent of lead-containing paints. This included samples from exterior finishes throughout the building. Samples were analyzed using a Niton XL-700 X-Ray Fluorescence (XRF) spectrum analyzer. The XRF analyzer can measure lead contents of several layers of paint without disturbing the surfaces, thus giving immediate feedback on lead contents of paint without destructive testing. The XRF is sensitive to 0.1 milligrams per square centimeter (mg/cm
) of lead, or well below HUD guideline levels of 1.0 mg/cm of lead in paints.
XRF analysis data are reported as L-shell values. The L-shell value is the lower energy fluorescence showing the level of the surface layer that is readily disturbed and potentially made airborne, thereby posing a potential construction health hazard.
Please note that although LBP were defined against the HUD standard, OSHA's Construction Lead Standard, 29 CFR 1926.62, applies to all paints with any measured lead content, requiring dust control measures to reduce airborne and ingestion lead dust hazards.
SCA Project No.: B-12033 Page 8
4.0 Applicable Standards
4.1 Asbestos-Containing Materials
ACM is defined by EPA regulations as those substances containing greater than 1% asbestos. The New Mexico Environmental Department’s Air Quality Bureau (AQB) provides local enforcement of these regulations. Friable ACM with greater than 1% asbestos needs to be disposed of as asbestos waste.
Regulated Asbestos-Containing Materials (RACM) is defined as (a) Friable – the material can be crumbled, pulverized or reduced to powder by hand pressure, (b) Category 1 that are subjected to sanding, grinding, cutting or abrasion, (c) Category I materials that becomes friable during demolition or renovation activities, or (d) Category II materials that become friable during demolition or renovation activities.
Federal Occupational Safety and Health Administrations (OSHA) regulations, locally enforced by New Mexico OSHA, define ACM as substances that contain greater than 1% asbestos. OSHA also mandates special training, medical exams, personal protective equipment and record keeping for employees working with ACM. If a material contains less than 1% asbestos but more than 0.1% asbestos, the material may be disposed of as non-ACM, but the OSHA requirements would still have to be followed regarding workers' protection and Contractor licensing.
"Trace" materials are currently regulated in OHSA and require the following:
Removal using wet methods;
Prohibition of removal using abrasive saws or methods which would aerosolize the material, without dust collection or dust suppression systems utilized in conjunction with these means and methods; and
Prompt clean-up of the impacted zone, using HEPA-filtered vacuums, as applicable.
Further detail regarding various New Mexico asbestos regulations can be found from the following websites:
https://www.env.nm.gov/aqb/asbestos/ http://164.64.110.239/nmac/parts/title20/20.009.0008.htm for asbestos disposal requirements http://www.epa.gov/asbestos/pubs/help.html http://www.epa.gov/asbestos/pubs/asbreg.html
4.2 Lead-Based Paints
Since elemental lead is a suspect carcinogen and known teratogen and neurotoxic in high doses, lead-containing materials need to be identified prior to the on-set of demolition activities. Using combinations of engineering controls and personal protective equipment, lead-containing materials can be remediated safely. Several sources of applicable standards are listed as follows:
1. Occupational Exposure: Lead exposures in the workplace are regulated by OSHA, which has certain regulatory requirements for identifying and controlling potential lead exposures. Currently applicable regulations for the construction industry have been adopted from the Federal OSHA regulations. The current OSHA 8-hour Permissible Exposure Level (PEL) for lead is 50 µg/m
2. Lead Waste: The maximum allowable concentration of lead for non-hazardous waste disposal in New
Mexico id 5.0 mg/l per U.S. EPPA test method 1311 toxicity characteristic leaching procedures (TCLP) per New Mexico Title 20 Chapter 9, Part 8, Paragraph 16
3. Definitions & Notifications: The major definitions of LBP or lead-coated surfaces are listed as follows:
https://www.env.nm.gov/aqb/asbestos/ http://164.64.110.239/nmac/parts/title20/20.009.0008.htm http://www.epa.gov/asbestos/pubs/help.html http://www.epa.gov/asbestos/pubs/asbreg.html
SCA Project No.: B-12033 Page 9
a. HUD defines LBP as paint that contains either >0.5% by weight of lead, or >1 mg/cm2.
b. Consumer Product Safety Commission (CPSC) prohibits the manufacturing of paint that contains more than 600 ppm (0.06%) of lead.
Given the myriad of confusing definitions and regulations, this report uses the HUD's definition for the purpose of identifications, but compliance to OSHA's Construction Lead Standard is required for all paints with any measurable lead content.
4. New Renovation, Repair and Painting Rules finalized by the U.S. Environmental Protection Agency on June 23, 2008, authorized under section 402(c )(3) of the Toxic Substances Control Act (TSCA) require any Contractor or Maintenance Personnel disturbing more than 6 sq. ft. of interior or 20 sq. ft. of exterior lead-based paints (LBPs) in pre-1978 housing or child-occupied facilities to complete EPA-accredited training or 4-hr. EPA-accredited refresher training, as applicable, for lead safe work practices. Persons performing renovations, repairs and/or painting projects in target housing or child-occupied facilities must provide “Renovate Right” brochures to the Owners and occupants after December 22, 2008. Window replacements are subject to the standards. These standards prohibit certain dangerous work practices, such as open flame burning or torching of lead-based paints. Required work practices include posting of warning signs, restricting occupants from work areas, containing work areas to prevent dust and debris from spreading, conducting a thorough cleanup and verifying that the cleanup is effective. Additional rules and information are available at www.epa.gov/lead.
“Certified Renovators” shall perform the following tasks:
Perform or direct uncertified workers performing regulated renovation activities;
Provide training to uncertified workers on lead safe work practices;
Be on-site during key stages of the renovation and otherwise be available on-site or by telephone at other times;
Use an acceptable lead test kit to determine whether lead-based paints are present in an affected area.
Firms may apply for certification beginning in October 2009 and must be certified by April 2010.
http://www.epa.gov/lead
SCA Project No.: B-12033 Page 10
5.0 Results and Conclusions
5.1 Asbestos
The detailed results are shown in the Laboratory Report in Attachment 1. Sample locations are shown on the drawings included as Attachment 4.
Sampling by SCA in May, 2016 and Anderson Halls Architects in October 2011 found the following ACM:
Mudded elbows on the heating hot water and domestic hot water system sampled in the Basement Stairs and
Basement Storage Room and considered typical of the non-abated segments and concealed risers and branches throughout the building [SCA Sample I.D. OSFT-TSI-107-1 & 2 with 10% Chrysotile].
White interior plasters over gray base plasters with horse hair sampled in Annex Building Room A5 western perimeter façade [SCA Sample I.D. OSFT-WLPL-104-10 with 2% Chrysotile in the brown base layer] [Note the interior plasters throughout the Annex Building shall be treated as asbestos-containing].
White interior plasters over gray base plasters with horse hair sampled in Annex Building Shop A5 southern perimeter façade [SCA Sample I.D. OSFT-WLPL-104-11 with 2% Chrysotile in the brown base layer]
[Note the interior plasters throughout the Annex Building shall be treated as asbestos-containing].
Note that the thermal system insulation was abated during the boiler replacement project within the past 3 to 4 years.
However, mudded elbows and remnants of the original system are still visible in the Crawl Space Tunnels and the Basement Records and Storage Rooms as well as at concealed risers and branches on both the heating hot water system and the domestic hot water system. The extent of required abatement for the seismic renovations is unknown but could impact segments of these systems if plaster removal is required indoors.
Note that heating hot water lines to the 2 nd Floor appear to run within the perimeter walls. If seismic renovations require partial demolition of the plasters within these areas, these lines may be exposed, such that abatement will be feasible. If seismic upgrades do not impact these plasters, then abatement of the TSI should generally not be necessary at this time.
Interior plasters throughout the Annex Building shall be treated as ACM based on the serial analyses completed for these samples. Interior plasters in the Main Building were all found to be non-asbestos.
Suspect materials that were not sampled but should be assumed to be asbestos-containing include the following:
Suspect older vinyl floor tiles and associated mastics under carpeting in various locations [SCA Sample I.D.
OSFT-FLVCT-AAA, assumed ACM].
Destructive testing may be warranted for the above suspect ACM following vacancy of the building or area to ascertain the validity of the assumptions.
“Trace” asbestos-containing materials (>0.1% and <1% asbestos by weight) sampled by SCA include:
Pink white stucco skimcoat over gray base coat and non-ACM building paper sampled on the 1
Floor west facade [AHA Sample I.D. #1 W1 with <1% Chrysotile in the skimcoat and base stucco plasters].
Pink white stucco skimcoat over brown/gray base coat over reddish/gray stuccos with white fibrous debris sampled on the 1 st Floor south facade [AHA Sample I.D. #4 S1 with <1% Chrysotile in all layers].
Pink multi-colored stucco plaster over non-ACM building paper over pink/gray and red/gray older stucco plasters sampled on the 2 nd
Floor west facade [AHA Sample I.D. #5 W2 with <1% Chrysotile in the pink multi-colored layer].
SCA Project No.: B-12033 Page 11
Multi-layered exterior stucco plasters sampled at SW Annex corner with sandy tea-colored layer over older orange-yellow layer [SCA Sample I.D. OSFT-STUCCO-101-1 with <1% Chrysotile in the brown layer]
[Note that a 1,000 point cont of this sample found <0.1% Chrysotile].
Despite a large number of samples showing no detectable asbestos in the multi-layered exterior stucco plasters, sampling in 2011 and 2016 found ‘trace’ Chrysotile in various layers. Because the removal of this material generally requires sawing into workable segments and pulverizing the materials, airborne asbestos releases are likely to occur during these operations and SCA deems that the material must be removed under full isolation procedures in compliance with 29 CFR 1926.1101 Work Class 2 procedures. The 1,000 point count of the stucco found the asbestos content at <0.1% Chrysotile, so the materials generally can be disposed as non-hazardous waste.
Recommended abatement procedures would include scaffolding and shrink-wrapping the exterior stucco areas throughout. This will allow for full isolation of the abatement activities and weather protection during the reconstruction phase.
5.2 Non-Asbestos Materials (non-ACM)
Non-asbestos materials sampled by SCA include:
Pink white stucco skimcoat over pink base coat sampled on the 1
Floor east facade [AHA Sample I.D. #2
E1].
Brown/gray stucco plasters sampled on the 1 st Floor north facade [AHA Sample I.D. #3 N1].
Multi-layered exterior stucco plasters with thin elastomeric layer over gray base over lighter gray base at
Annex Greenhouse southern curb [SCA Sample I.D. OSFT-STUCCO-101-1].
Multi-layered exterior stucco plasters with tea-colored layer over gray base layer over lighter gray layer sampled at south Annex façade outside Room A3 [SCA Sample I.D. OSFT-STUCCO-101-3].
Multi-layered exterior stucco plasters with tea-colored layer over gray base layer over lighter gray layer sampled at south Annex façade’s window outside Room A4 [SCA Sample I.D. OSFT-STUCCO-101-4].
Multi-layered exterior stucco plasters with tea-colored layer over gray base layer over lighter gray layer sampled at South Main Building façade outside Room 128 [SCA Sample I.D. OSFT-STUCCO-101-5].
Multi-layered exterior stucco plasters with tea-colored layer over gray base layer over lighter gray layer sampled at west Main Building façade outside Rm. 124 [SCA Sample I.D. OSFT-STUCCO-101-6].
Multi-layered exterior stucco plasters with tea-colored layer over gray base layer over lighter gray layer sampled at south Main Building façade at the bike racks outside Rm. 116 [SCA Sample I.D. OSFT-
STUCCO-101-7].
Multi-layered exterior stucco plasters with tea-colored layer over gray base layer over lighter gray layer sampled at west Main Building Entry Courtyard wall [SCA Sample I.D. OSFT-STUCCO-101-8].
Multi-layered exterior stucco plasters with tea-colored layer over gray base layer over lighter gray layer sampled at north Main Building outside Rm. 115B [SCA Sample I.D. OSFT-STUCCO-101-9].
Multi-layered exterior stucco plasters with tea-colored layer over gray base layer over lighter gray layer sampled at north Main Building façade outside Rm. 112 [SCA Sample I.D. OSFT-STUCCO-101-10].
Multi-layered exterior stucco plasters with tea-colored layer over gray base layer over lighter gray layer sampled at north Main Building façade at Entry [SCA Sample I.D. OSFT-STUCCO-101-11].
SCA Project No.: B-12033 Page 12
Multi-layered exterior stucco plasters with tea-colored layer over gray base layer over lighter gray layer sampled at north patio outside Conference Rm. 108 with white paints [SCA Sample I.D. OSFT-STUCCO-
101-12].
Multi-layered exterior stucco plasters with newer tea-colored over older tea-colored layer over gray base layer over lighter gray layer sampled at eastern Main Building façade outside Rm. 127 [SCA Sample I.D.
OSFT-STUCCO-101-13].
Multi-layered exterior stucco plasters with newer tea-colored over older tea-colored layer over gray base layer over lighter gray layer sampled at eastern Main Building façade outside 2 nd
Floor Office 207 [SCA
Sample I.D. OSFT-STUCCO-101-14].
Multi-layered exterior stucco plasters with newer tea-colored over older tea-colored layer over gray base layer over lighter gray layer typical for replacement parapet caps throughout [SCA Sample I.D. OSFT-
STUCCO-101-15].
Multi-layered exterior stucco plasters with tea-colored layer over gray base layer over lighter gray layer sampled at western Main Building façade outside 2 nd
Floor Rm. 204 [SCA Sample I.D. OSFT-STUCCO-
101-16].
Multi-layered exterior stucco plasters with tea-colored layer over gray base layer over lighter gray layer sampled at western Main Courtyard with white paints and typical of Main Courtyard throughout [SCA
Sample I.D. OSFT-STUCCO-101-17].
Taupe-colored exterior stucco plasters over gray stucco sampled from interior of the Annex Mail Room
[SCA Sample I.D. OSFT-STUCCO-101-18].
Built-up tar and gravel roof replaced about 10 years ago over insulation layer over decking, typical of roofing throughout [SCA Sample I.D. OSFT-RFAG-102-1] [Note that PVC roofing overlays the built-up roofing for the 2 nd
Floor Main Building].
Red, yellow and brown caulking at perimeter windows sampled at exterior of 2 nd
Floor Rooms 204 & 206 and considered typical throughout [SCA Sample I.D. OSFT-CAULK-103-1 & 2].
Yellow and brown perimeter window caulking sampled at exterior of 2 nd
Floor Room 203 and considered typical throughout [SCA Sample I.D. OSFT-CAULK-103-3].
Yellow and gray caulking at cracked stucco plaster sampled at parapets and considered typical throughout
[SCA Sample I.D. OSFT-CAULK-103-4].
White interior plasters over gray base plasters sampled in Great Room 132 western perimeter façade [SCA
Sample I.D. OSFT-WLPL-104-1].
White interior plasters over gray base plasters sampled in Great Room 132 eastern perimeter façade [SCA
Sample I.D. OSFT-WLPL-104-2].
White interior plasters over gray base plasters sampled in Conference Rm. 108 eastern perimeter façade
[SCA Sample I.D. OSFT-WLPL-104-3].
White interior plasters over gray base plasters with horse hair sampled in Electrical Room off Stairway eastern perimeter façade [SCA Sample I.D. OSFT-WLPL-104-4].
White interior plasters over gray base plasters with horse hair sampled in Electrical Room off Stairway
SCA Project No.: B-12033 Page 13 northern perimeter façade [SCA Sample I.D. OSFT-WLPL-104-5].
White interior plasters over gray base plasters with horse hair sampled in 2 nd
Floor Copy Room western perimeter facade [SCA Sample I.D. OSFT-WLPL-104-6].
White interior plasters over gray base plasters with horse hair sampled in the 2 nd
Floor Hallway eastern perimeter facade [SCA Sample I.D. OSFT-WLPL-104-7].
White interior plasters over gray base plasters with horse hair sampled in 1 st Floor Room 123 western perimeter facade [SCA Sample I.D. OSFT-WLPL-104-8].
White interior plasters over gray base plasters with horse hair sampled in the Basement Boiler Room eastern perimeter façade [SCA Sample I.D. OSFT-WLPL-104-9].
Gray mortars at stone facades sampled in the 1 st Floor Electrical Room, Basement Electrical Closet and
Basement Boiler Room and considered typical throughout [SCA Sample I.D. OSFT-MORTAR-105-1 thru
3].
Brown expansion joint at the Main Courtyard concrete ramp to the Toilets [SCA Sample I.D. EXPJT-106-
1].
12-inch square beige splotched patterned vinyl composite floor tiles with yellow mastics over concrete sampled in the Basement Records Room and typical of the 1 st Floor Copy Room [SCA Sample I.D. OSFT-
FLVCT-108-1].
2-ft. by 4-ft. laid-in ceiling tiles with pinhole and crowfoot pattern sampled in the Basement Records Room
[SCA Sample I.D. OSFT-CLLI-109-1].
New sheetrock wallboard in the Basement Records Room [SCA Sample I.D. OSFT-WLSH-NNN].
New sheetrock wallboard in the Annex Building Mail Room A1 [SCA Sample I.D. OSFT-WLSH-NNN].
New 12-inch square off-white vinyl composite floor tiles and associated mastics in the Annex Building Mail
Room A1 [SCA Sample I.D. OSFT-FLVCT-NNN].
New 12-inch square beige splotched patterned vinyl composite floor tiles and associated mastics in the 1
Floor Vending Room [SCA Sample I.D. OSFT-FLVCT-NNN].
5-inch high various colored vinyl baseboards and associated white mastics over plaster and sheetrock substrates throughout [SCA Sample I.D. OSFT-BBMAS-NNN].
5.3 Lead-Based Paints
Lead-based paints (LBP), as defined by U.S. Department of Housing and Urban Development (HUD), were identified at the site, including but not necessarily limited to the following:
Off-white paints on the stucco exterior Courtyard façade outside Room 131 [SCA Sample I.D. OW-07-3 with 1.20 mg/cm
Rust-colored paints on the Main Courtyard stucco façade at Room 123 [SCA Sample I.D. RU-09-3 with 2.4 mg/cm
Rust-colored paints on the Main Courtyard exterior stucco façade at Room 115 [SCA Sample I.D. RU-09-4
SCA Project No.: B-12033 Page 14 with 1.80 mg/cm
Pink ceramic tile glazing in the Main Building’s Men’s Toilet [SCA Sample I.D. PK-14-1 with 6.80 mg/cm
Off-white paints on the entry wall plasters in Great Room 132 [SCA Sample I.D. OW-24-1 with 3.30 mg/cm
Various colored ceramic wall tile glazing in the Men’s & Women’s Toilets throughout.
Most site paints were found to be below the HUD LBP criteria, although dust control procedures are required throughout the demolition of painted elements to comply with the OSHA regulations under 29 CFR 1926.62. All site paints shall be treated as having a lead content greater than 600 ppm requiring dust control procedures in compliance with 29 CFR 1926.62.
Loose and peeling paints should be removed under controlled procedures prior to any demolition of the structure.
None of the applicable regulations require removal of LBP prior to demolition or renovation if the paints are securely adhered to the substrates (i.e., non-flaking or non-peeling). Disposal of the demolition debris in this case can be handled as non-hazardous and non-RCRA waste after the loose and flaking paints have been removed, as long as demolition practices do not compromise worker safety.
Conventional demolition techniques should be employed for all painted surfaces with the Contractor complying with applicable OSHA statutes regarding:
Worker awareness training;
Exposure monitoring, as needed;
Medical examinations, including blood lead level testing; and
Establishing a written respiratory protection program.
5.4 Other Hazards
SCA was requested to assess the presence of fecal matter on-site from past rodent infestations. Examination of the wet walls, crawl space tunnels and the topside of wiring and piping chases found evidence of past infestations;
however, the quantity of contamination is generally modest and can be readily cleaned using a HEPA-filtered vacuum. Fecal matter and HEPA vacuum contents shall generally be disposed as sanitary waste. PPE used shall minimally include protective gloves and a N-95 dust mask during cleanup.
SCA Project No.: B-12033 Page 15
6.0 Limitations and Exclusions
SCA warrants that this survey was performed using due care and state of the art techniques. Beyond this, SCA does not warrant or guarantee the survey. Despite the care exercised, some materials may not have been identified, or may have been incompletely identified. This condition may occur due to renovations or original construction practices that concealed older materials, and/or visually similar materials with different compositions.
This document is not a stand-alone document; abatement of materials is recommended to be completed under the oversight and design of an AHERA-accredited Project Designer and Certified Asbestos Consultant. Although due care is exercised in the course of the survey, concealed materials may be found in the course of performing the abatement or demolition; a contingency budget should be included in any cost estimates to cover unexpected conditions.
Note that SCA’s survey was geared to the waterproofing and roofing repairs as well as identifying substrates that may be impacted by the seismic upgrades. This survey was not a complete building survey and did not investigate flooring throughout the entire site.
Old Santa Fe Trail Building, 1100 Old Santa Fe Trail, Santa Fe, NM SCA Project No.: B-12033
Attachment 1
Laboratory Results - Asbestos
464 McCormick Street San Leandro, CA 94577
Tel/Fax: (510) 895-3675 / (510) 895-3680 http://www.EMSL.com / sanleandrolab@emsl.com
091608901EMSL Order:
Customer ID: SCAE50
Customer PO:
Project ID:
Attention: Phone:Glenn Cass (415) 882-1675
Fax:SCA Environmental (415) 962-0736
Received Date:650 Delancy Street 05/16/2016 12:45 PM
Analysis Date:Suite 222 05/19/2016
Collected Date:San Francisco, CA 94107
Project: B-12033 - GRC - SANTA FE TRAIL - 5/11/16
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light
Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
STUCCO-101-1-Stucco
091608901-0001
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Tan
Non-Fibrous
Homogeneous
STUCCO-101-1-Stucco
091608901-0001A
<1% ChrysotileQuartz
Non-fibrous (Other)
50%
50%
Brown
Non-Fibrous
Homogeneous
STUCCO-101-2-Stucco
091608901-0002
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Gray
Non-Fibrous
Homogeneous
STUCCO-101-2-Stucco
091608901-0002A
None DetectedQuartz
Non-fibrous (Other)
40%
60%
Brown
Non-Fibrous
Homogeneous
STUCCO-101-3-Stucco
091608901-0003
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Gray
Non-Fibrous
Homogeneous
STUCCO-101-3-Stucco
091608901-0003A
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Tan
Non-Fibrous
Homogeneous
STUCCO-101-4-Stucco
091608901-0004
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Gray
Non-Fibrous
Homogeneous
STUCCO-101-4-Stucco
091608901-0004A
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Tan
Non-Fibrous
Homogeneous
STUCCO-101-5-Stucco
091608901-0005
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Gray
Non-Fibrous
Homogeneous
STUCCO-101-5-Stucco
091608901-0005A
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Tan
Non-Fibrous
Homogeneous
STUCCO-101-6-Stucco
091608901-0006
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Gray
Non-Fibrous
Homogeneous
STUCCO-101-6-Stucco
091608901-0006A
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Tan
Non-Fibrous
Homogeneous
Initial Report From: 05/20/2016 12:52:52
Page 1 of 5PLM - 1.69 Printed: 5/20/2016 12:52 PM
Tel/Fax: (510) 895-3675 / (510) 895-3680 http://www.EMSL.com / sanleandrolab@emsl.com
091608901EMSL Order:
Customer ID: SCAE50
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light
Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
STUCCO-101-7-Stucco
091608901-0007
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Gray
Non-Fibrous
Homogeneous
STUCCO-101-7-Stucco
091608901-0007A
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Tan
Non-Fibrous
Homogeneous
STUCCO-101-8-Stucco
091608901-0008
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Gray
Non-Fibrous
Homogeneous
STUCCO-101-8-Stucco
091608901-0008A
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Tan
Non-Fibrous
Homogeneous
STUCCO-101-9-Stucco
091608901-0009
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Gray
Non-Fibrous
Homogeneous
STUCCO-101-9-Stucco
091608901-0009A
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Tan
Non-Fibrous
Homogeneous
STUCCO-101-10-Stucc o 1
091608901-0010
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Gray
Non-Fibrous
Homogeneous
STUCCO-101-10-Stucc o 2
091608901-0010A
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Tan
Non-Fibrous
Homogeneous
STUCCO-101-11-Stucc o 1
091608901-0011
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Gray
Non-Fibrous
Homogeneous
STUCCO-101-11-Stucc o 2
091608901-0011A
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Tan
Non-Fibrous
Homogeneous
STUCCO-101-12-Stucc o 1
091608901-0012
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Gray
Non-Fibrous
Homogeneous
STUCCO-101-12-Stucc o 2
091608901-0012A
None DetectedQuartz
Non-fibrous (Other)
50%
50%
White
Non-Fibrous
Homogeneous
STUCCO-101-13-Stucc o 1
091608901-0013
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Gray
Non-Fibrous
Homogeneous
STUCCO-101-13-Stucc o 2
091608901-0013A
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Tan
Non-Fibrous
Homogeneous
STUCCO-101-14-Stucc o 1
091608901-0014
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Gray
Non-Fibrous
Homogeneous
Page 2 of 5PLM - 1.69 Printed: 5/20/2016 12:52 PM
Tel/Fax: (510) 895-3675 / (510) 895-3680 http://www.EMSL.com / sanleandrolab@emsl.com
091608901EMSL Order:
Customer ID: SCAE50
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light
Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
STUCCO-101-14-Stucc o 2
091608901-0014A
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Pink
Non-Fibrous
Homogeneous
STUCCO-101-14-Stucc o 3
091608901-0014B
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Brown
Non-Fibrous
Homogeneous
STUCCO-101-15-Stucc o 1
091608901-0015
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Gray
Non-Fibrous
Homogeneous
STUCCO-101-15-Stucc o 2
091608901-0015A
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Tan
Non-Fibrous
Homogeneous
STUCCO-101-16-Stucc o 1
091608901-0016
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Gray
Non-Fibrous
Homogeneous
STUCCO-101-16-Stucc o 2
091608901-0016A
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Tan
Non-Fibrous
Homogeneous
STUCCO-101-17
091608901-0017
None DetectedQuartz
Non-fibrous (Other)
50%
50%
White
Non-Fibrous
Homogeneous
STUCCO-101-18
091608901-0018
None DetectedQuartz
Non-fibrous (Other)
50%
50%
Brown
Non-Fibrous
Homogeneous
RFAG-102-1-Roofing
091608901-0019
None DetectedNon-fibrous (Other)80%Glass20%Black
Fibrous
Homogeneous
RFAG-102-1-Insulation
091608901-0019A
None DetectedNon-fibrous (Other)40%Cellulose60%Tan
Fibrous
Homogeneous
CAULK-103-1
091608901-0020
None DetectedCa Carbonate
Matrix
Non-fibrous (Other)
30%
60%
10%
Brown/White
Non-Fibrous
Homogeneous
CAULK-103-2
091608901-0021
None DetectedCa Carbonate
Matrix
Non-fibrous (Other)
30%
60%
10%
Brown/White
Non-Fibrous
Homogeneous
CAULK-103-3
091608901-0022
None DetectedCa Carbonate
Matrix
Non-fibrous (Other)
30%
60%
10%
Brown/White
Non-Fibrous
Homogeneous
CAULK-103-4
091608901-0023
None DetectedCa Carbonate
Matrix
Non-fibrous (Other)
30%
60%
10%
Brown/White
Non-Fibrous
Homogeneous
MORTAR 105-1
091608901-0024
None DetectedQuartz
Ca Carbonate
Gypsum
Non-fibrous (Other)
40%
15%
25%
20%
Gray
Non-Fibrous
Homogeneous
MORTAR 105-2
091608901-0025
None DetectedQuartz
Ca Carbonate
Gypsum
Non-fibrous (Other)
40%
15%
25%
20%
Gray
Non-Fibrous
Homogeneous
Page 3 of 5PLM - 1.69 Printed: 5/20/2016 12:52 PM
Tel/Fax: (510) 895-3675 / (510) 895-3680 http://www.EMSL.com / sanleandrolab@emsl.com
091608901EMSL Order:
Customer ID: SCAE50
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light
Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
MORTAR 105-3
091608901-0026
None DetectedQuartz
Ca Carbonate
Gypsum
Non-fibrous (Other)
40%
15%
25%
20%
Gray
Non-Fibrous
Homogeneous
WLPL-104-1
091608901-0027
None DetectedCa Carbonate
Gypsum
Non-fibrous (Other)
60%
20%
20%
White
Non-Fibrous
Homogeneous
WLPL-104-2
091608901-0028
None DetectedCa Carbonate
Gypsum
Non-fibrous (Other)
60%
20%
20%
White
Non-Fibrous
Homogeneous
WLPL-104-3
091608901-0029
None DetectedQuartz
Ca Carbonate
Gypsum
Non-fibrous (Other)
35%
15%
25%
25%
White
Non-Fibrous
Homogeneous
WLPL-104-4-Plaster 1
091608901-0030
None DetectedQuartz
Ca Carbonate
Gypsum
Non-fibrous (Other)
40%
15%
25%
17%
Cellulose3%Tan
Non-Fibrous
Homogeneous
WLPL-104-4-Plaster 2
091608901-0030A
None DetectedCa Carbonate
Gypsum
Non-fibrous (Other)
60%
20%
20%
White
Non-Fibrous
Homogeneous
WLPL-104-5-Plaster 1
091608901-0031
None DetectedQuartz
Ca Carbonate
Gypsum
Non-fibrous (Other)
40%
15%
25%
18%
Cellulose2%Tan
Non-Fibrous
Homogeneous
WLPL-104-5-Plaster 2
091608901-0031A
None DetectedCa Carbonate
Gypsum
Non-fibrous (Other)
60%
20%
20%
White
Non-Fibrous
Homogeneous