A06_Updated_Material_Specifications_0001.pdf

PDF 119 KB Posted

Attached to
7 LAKES FENCE REPAIR
Solicitation number
140LL027Q0034
Issued by
Not on record

About this file

This document is a Material Specifications sheet for the 7 Lakes 2026 Fence project, issued by the Rawlins Wyoming BLM Field Office. The specifications detail the requirements for all materials needed for fence construction, including barbed wire, barbless wire, wood stays, and both steel and wood posts.

Barbed wire must consist of two 12-1/2-gauge galvanized wires twisted together with 2-point barbs spaced 4 inches apart, conforming to ASTM A 121 with a minimum breaking strength of 950 lb-force and zinc coating of at least 0.3 oz/ft² of coated surface area. Barbless wire follows identical specifications except without barbs. Wood stays must be 42 inches tall with a diameter between 2.5 and 4 inches, straight and plumb. Steel fence posts must comply with ASTM A 702, be 5.5 feet in length, painted green with white or silver tops, feature "T" bar type construction with clip-type wire fasteners, minimum weight of 1.33 lb/ft, and anchor plates weighing a minimum of 0.67 pounds (±5 percent) with an area of at least 18 square inches positioned 18 inches from the post bottom. Wood posts and braces must be 6.5 feet in length from acceptable species (Ponderosa pine, Lodgepole pine, fir, or tamarack) with 6-inch nominal diameter, free of bark, and treated using the Chromate Copper Arsenic method per AWPA standards with a minimum net retention of 0.4 pounds per cubic foot using full-cell pressure treatment. Suppliers must submit written material approvals and an independent testing laboratory assay report (minimum five-inch boring samples from each bundle of 50 posts) to Andy Skordas at askordas@blm.gov, Rawlins Wyoming BLM Field Office, prior to shipping. Contact information: 307-320-5714.

View the file

Other files

File Type Posted
A06_Wire_Fence_and_Gates_0001.pdf PDF
Sol_140LL027Q0034_Amd_0001.pdf PDF
A06_Drawings.pdf PDF
A04_SOW.pdf PDF
A06_Specifications.pdf PDF
A06_Maps.pdf PDF
Sol_140LL027Q0034.pdf PDF
B03_DBA_Wage_Determination.pdf PDF
Bid_Schedule.xlsx XLSX spreadsheet

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Material Specifications

7 LAKES 2026 FENCE

Specifications

A. Barbed Wire: A strand of two 12-1/2-gauge galvanized wires twisted together with 2-point barbs of 14-gauge wire spaced 4-inches apart. Wire and barbs shall be zinc-coated steel, with a zinc coating of at least 0.3 oz/ft2 of coated surface area. The minimum breaking strength of each wire shall be 950 lb-force. The barbed wire shall conform to ASTM A 121.

B. Barbless Wire: A strand of two 12-1/2-gauge galvanized wires twisted together. Wire shall be zinc-coated steel wire of at least 0.3 oz/ft2 of coated surface area. The minimum breaking strength of each wire shall be 950 lb-force. The barbless wire shall conform to ASTM A 121.

C. Wood Stays: Sound single stem wood stays must be straight and plumb. Wood stay dimensions shall be 42in. tall with a diameter of 2.5in.-4in..

D. Steel Fence Posts: ASTM A 702; painted green with white or silver tops "T" bar type, with a welded or riveted anchor plate. Furnish with clip-type wire fasteners (punched tabs for fastening wires are not acceptable). Steel posts shall be manufactured from wrought, rail, or new billet steel, and shall have a minimum weight of 1.33 lb/ft. The anchor plates shall weigh a minimum of 0.67 pounds +5 percent, be a minimum of 18 square inches in area, and be 18-inches from the bottom of the post. The posts shall be 5.5’ in length.

E. Wood Posts and Braces:

1. Acceptable Wood Posts: Sound single-stem members. A slight bend in one plane is acceptable. Posts may be full stem members, sawed members of square cross section, or split members (western red cedar only). Nominal diameter for treated posts shall be 6-inches. The following species will be acceptable:

Ponderosa pine, Lodgepole pine, fir, and tamarack. All treated posts shall be free of bark with ends cut square. All wood posts shall be 6.5’ in length.

2. Basis for Rejection: Posts are not acceptable when sweep causes a straight line joining the center of the top to the center of the butt to fall outside the body of the post, or at point 2-inches or more from the center of the post. Posts that are

Material Specifications

7 LAKES 2026 FENCE

charred, twisted, rotted, or excessively bent are not acceptable. Seasoning checks, single or opposite each other with a sum total equal to or more than 1/2 the thickness of the post are not acceptable.

3. Wood Treatment Practices: General: The following treatments may be used.

Treatment method shall be in accordance with AWPA C 1.

1. Chromate Copper Arsenic Method: chromate copper arsenate, waterborne preservative (conforming to Type B in AWPA 5) shall be applied. Minimum net retention of solid preservative shall be 0.4 pounds per cubic foot (gauge only) using the full-cell pressure treatment process.

2. Assay Report: The Supplier shall furnish an assay report, for all treated wood products, from an independent testing laboratory to the Contracting Officer. A minimum of five inch boring shall be taken from each bundle of 50 posts as samples for the assay report.

A written submittal for all materials shall be submitted for approval to Andy Skordas (askordas@blm.gov) Rawlins Wyoming BLM Field Office prior to shipping the products. Contact Andy Skordas with any questions 307-320-5714.

mailto:askordas@blm.gov

File details come from the government source that posted it. Updated .