This document is a standard detail drawing specification from the United States Department of the Interior Bureau of Land Management for typical barbed wire fences and wire gates used on federal lands. The drawing, dated April 26, 1997 (with format updates on 7/31/09), provides comprehensive technical specifications for four-wire barbed wire fence construction and related gate configurations.
The specification includes multiple panel types and configurations: End Panel Type I and Type II with varying minimum brace dimensions (6'-0" to 6'-6"), stress panels, line panels with twisted wire or wood stays, panels at minor depression locations, and three distinct corner panel designs (3-post, 5-post Type I, and 5-post Type II). Wire gates are detailed in three configurations (Woven Wire Gate, Wire Gate Type A, and Wire Gate Type B), all featuring panel post spacing of 16'-6" (5029 mm) center-to-center with mechanical gate closers. Construction specifications include 9-gauge smooth galvanized wire, wood or steel line posts, minimum 4"-3" (76 mm) diameter wood stays evenly spaced, and a mortise detail showing spike or toe nailing specifications. Key dimensional requirements include minimum post depths of 6" (152 mm) and spacing standards between bottom wire and ground not exceeding 20" (508 mm). The document serves as a reference standard for contractors and land managers constructing or maintaining boundary and livestock containment fencing on interior department properties.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| A04_SOW.pdf | ||
| A06_Specifications.pdf | ||
| A06_Maps.pdf | ||
| Sol_140LL027Q0034.pdf | ||
| B03_DBA_Wage_Determination.pdf | ||
| Bid_Schedule.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AutoCAD SHX Text h
AutoCAD SHX Text H
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text H
AutoCAD SHX Text h
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text
6'-6" MIN.
AutoCAD SHX Text
6'-0" MIN.
AutoCAD SHX Text
6'-6" MIN.
AutoCAD SHX Text
6'-6" MIN.
AutoCAD SHX Text
6'-6" MIN.
AutoCAD SHX Text L
AutoCAD SHX Text
SEE MORTISE DETAIL
AutoCAD SHX Text 6'-6" (1981 mm) MIN. BRACE
AutoCAD SHX Text
SPIKE
AutoCAD SHX Text
9-GA. SMOOTH GALV. WIRE
AutoCAD SHX Text
ADD ADDITIONAL WIRE OF THE SAME MATERIAL AS BOTTOM WIRE
AutoCAD SHX Text OF FENCE & A ROCK DEADMAN (MIN. WEIGHT 50 LBS (22.5 kg)) WHEN
AutoCAD SHX Text SPACE BETWEEN BOTTOM WIRE & GROUND EXCEED 20" (508 mm).
AutoCAD SHX Text
LINE POST
AutoCAD SHX Text
(WOOD OR
AutoCAD SHX Text
STEEL)
AutoCAD SHX Text
%%UEND PANEL-TYPE I
AutoCAD SHX Text
%%UEND PANEL-TYPE II
AutoCAD SHX Text
%%UPANEL AT MINOR DEPRESSION
AutoCAD SHX Text
%%USTRESS PANEL
AutoCAD SHX Text h
AutoCAD SHX Text H
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text H
AutoCAD SHX Text h
AutoCAD SHX Text L
AutoCAD SHX Text L
AutoCAD SHX Text L
AutoCAD SHX Text 2" (51 mm) MIN.
AutoCAD SHX Text
TWISTED WIRE OR WOOD STAY
AutoCAD SHX Text
STEEL LINE POST
AutoCAD SHX Text
1. SEE SPECIFICATIONS FOR THE FOLLOWING:
AutoCAD SHX Text
A. RATIO OF STEEL TO WOOD LINE POSTS.
AutoCAD SHX Text
B. POST SPACING, LENGTH & DEPTH IN GROUND.
AutoCAD SHX Text
C. TYPE OF END PANEL TO BE USED.
AutoCAD SHX Text
D. TYPE OF WIRE TO BE USED.
AutoCAD SHX Text
E. SPACING BETWEEN WIRES.
AutoCAD SHX Text
F. NUMBER OF STAYS PER SPAN (L).
AutoCAD SHX Text
SPIKE (SPIKING
AutoCAD SHX Text
OR TOE NAILING
AutoCAD SHX Text
AS SPECIFIED)
AutoCAD SHX Text
%%ULINE PANELS
AutoCAD SHX Text
%%UMORTISE DETAIL
AutoCAD SHX Text
%%UNOTES:
AutoCAD SHX Text 1" (25 mm)
AutoCAD SHX Text 1" (25 mm)
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text (1829 mm)
AutoCAD SHX Text (1981 mm)
AutoCAD SHX Text (1981 mm)
AutoCAD SHX Text (1981 mm)
AutoCAD SHX Text (1981 mm)
AutoCAD SHX Text
2. THE METRIC CONVERSIONS ARE PROVIDED IN PARENTHESIS
AutoCAD SHX Text
FOLLOWING THE ENGLISH UNITS.
AutoCAD SHX Text
NONE
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 02824-1
AutoCAD SHX Text
SHEET: 1 OF 1
AutoCAD SHX Text
REVIEWED
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DATE: APRIL 26, 1997
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
ALWAYS THINK
AutoCAD SHX Text
SAFETY
AutoCAD SHX Text
STANDARD DETAIL DRAWING NO.
AutoCAD SHX Text
UNITED STATES DEPARTMENT OF THE INTERIOR
AutoCAD SHX Text
BUREAU OF LAND MANAGEMENT
AutoCAD SHX Text
TYPICAL BARBED WIRE FENCE (4-WIRE)
AutoCAD SHX Text
REV. NO.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text 9/30/97
AutoCAD SHX Text
LJP
AutoCAD SHX Text
METRIC CONVERSION ADDED
AutoCAD SHX Text
BY OTHERS
AutoCAD SHX Text
AutoCAD SHX Text
N:\PROJECTS\STANDARD DRAWINGS\STDDWGS2009\02824-1.DWG
AutoCAD SHX Text 7/31/09
AutoCAD SHX Text
AutoCAD SHX Text
RTH
FORMAT UPDATE
12" (305 mm)
AutoCAD SHX Text H1
AutoCAD SHX Text h1
AutoCAD SHX Text PANEL POST SPACING 16'-6" (5029 mm) C.C.
AutoCAD SHX Text
SMOOTH WIRE LOOP (SEE SPECIFICATIONS FOR GAUGE)
AutoCAD SHX Text 4-3" (76 mm) O WOOD STAYS EVENLY SPACED
AutoCAD SHX Text
SMOOTH WIRE LOOP OR STEEL STRAP
AutoCAD SHX Text
(SEE SPECIFICATIONS FOR GAUGE)
AutoCAD SHX Text
MECHANICAL GATE CLOSER
AutoCAD SHX Text %%uWOVEN WIRE GATE
AutoCAD SHX Text h1
AutoCAD SHX Text H1
AutoCAD SHX Text
MECHANICAL GATE CLOSER
AutoCAD SHX Text
(SEE SPECIFICATIONS FOR GAUGE)
AutoCAD SHX Text
SMOOTH WIRE LOOP OR STEEL STRAP
AutoCAD SHX Text 3" (76 mm) MIN.
AutoCAD SHX Text 6" (152 mm) MIN.
AutoCAD SHX Text
SMOOTH WIRE LOOP (SEE SPECIFICATIONS FOR GAUGE)
AutoCAD SHX Text 4-3" (76 mm) O WOOD STAYS EVENLY SPACED
AutoCAD SHX Text PANEL POST SPACING 16'-6" (5029 mm) C.C.
AutoCAD SHX Text %%uWIRE GATE
AutoCAD SHX Text
TYPE A
AutoCAD SHX Text %%uWIRE GATE
AutoCAD SHX Text PANEL POST SPACING 16'-6" (5029 mm) C.C.
AutoCAD SHX Text 4-3" (76 mm) O WOOD STAYS EVENLY SPACED
AutoCAD SHX Text
SMOOTH WIRE LOOP (SEE SPECIFICATIONS FOR GAUGE)
AutoCAD SHX Text 6" (152 mm) MIN.
AutoCAD SHX Text 3" (76 mm) MIN.
AutoCAD SHX Text
SMOOTH WIRE LOOP OR STEEL STRAP
AutoCAD SHX Text
(SEE SPECIFICATIONS FOR GAUGE)
AutoCAD SHX Text
MECHANICAL GATE CLOSER
AutoCAD SHX Text H1
AutoCAD SHX Text h1
AutoCAD SHX Text
1. THE OPENING END OF GATE SHALL BE PROVIDED WITH SMOOTH WIRE LOOP AT BOTTOM
AutoCAD SHX Text
OF END STAY AS IS COMMON PRACTICE FOR FASTENING WIRE GAP GATES OR AS
AutoCAD SHX Text
MODIFIED FOR GATES WITH MECHANICAL GATE CLOSERS.
AutoCAD SHX Text
2. CONSTRUCT AN END OR STRESS PANEL ON EACH SIDE OF TYPE REQUIRED IN THE
AutoCAD SHX Text
SPECIFICATIONS.
AutoCAD SHX Text %%uNOTES:
AutoCAD SHX Text
TYPE B
AutoCAD SHX Text 12" (305 mm)
AutoCAD SHX Text 12" (305 mm)
AutoCAD SHX Text
3. THE METRIC CONVERSIONS ARE PROVIDED IN PARENTHESIS
AutoCAD SHX Text
FOLLOWING THE ENGLISH UNITS.
AutoCAD SHX Text
NONE
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 02824-6
AutoCAD SHX Text
SHEET: 1 OF 1
AutoCAD SHX Text
REVIEWED
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DATE: APRIL 26, 1997
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
ALWAYS THINK
AutoCAD SHX Text
SAFETY
AutoCAD SHX Text
STANDARD DETAIL DRAWING NO.
AutoCAD SHX Text
UNITED STATES DEPARTMENT OF THE INTERIOR
AutoCAD SHX Text
BUREAU OF LAND MANAGEMENT
AutoCAD SHX Text
TYPICAL WIRE GATES
AutoCAD SHX Text
REV. NO.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text 9/30/97
AutoCAD SHX Text
LJP
AutoCAD SHX Text
METRIC CONVERSION ADDED
AutoCAD SHX Text
BY OTHERS
AutoCAD SHX Text
AutoCAD SHX Text
N:\PROJECTS\STANDARD DRAWINGS\STDDWGS2009\02824-6.DWG
AutoCAD SHX Text 7/31/09
AutoCAD SHX Text
AutoCAD SHX Text
RTH
6'-6" MIN.
AutoCAD SHX Text %%u3-POST
AutoCAD SHX Text %%uCORNER PANEL
AutoCAD SHX Text
6'-6" MIN.
AutoCAD SHX Text
6'-0" MIN.
AutoCAD SHX Text
6'-6" MIN.
AutoCAD SHX Text
6'-6" MIN.
AutoCAD SHX Text %%u5-POST
AutoCAD SHX Text %%uCORNER PANEL
AutoCAD SHX Text %%u(TYPE I)
AutoCAD SHX Text %%u5-POST
AutoCAD SHX Text %%uCORNER PANEL
AutoCAD SHX Text %%u(TYPE II)
AutoCAD SHX Text %%uNOTES:
AutoCAD SHX Text
3. USE SPIKES AT JUNCTURES & MORTISE 1" (25 mm) DEEP AT JUNCTURES
AutoCAD SHX Text
4. MAX. SPACING BETWEEN POSTS SHALL BE 8'-3" (2515 mm) C.C.
AutoCAD SHX Text
2. NUMBER OF WIRES, TYPE OF WIRE, & WIRE SPACING SAME AS FOR FENCE.
AutoCAD SHX Text
1. REFER TO THE SPECIFICATIONS FOR TYPE OF CORNER PANELS TO USE.
AutoCAD SHX Text POSTS SHALL BE SET 6" (152 mm) DEEPER THAN LINE POSTS.
AutoCAD SHX Text (1981 mm)
AutoCAD SHX Text (1829 mm)
AutoCAD SHX Text (1981 mm)
AutoCAD SHX Text (1981 mm)
AutoCAD SHX Text (1981 mm)
AutoCAD SHX Text
5. THE METRIC CONVERSIONS ARE PROVIDED IN PARENTHESIS
AutoCAD SHX Text
FOLLOWING THE ENGLISH UNITS.
AutoCAD SHX Text
OF POSTS AND BRACES.
AutoCAD SHX Text
NONE
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 02824-9
AutoCAD SHX Text
SHEET: 1 OF 1
AutoCAD SHX Text
REVIEWED
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DATE: APRIL 26, 1997
AutoCAD SHX Text
DESIGNED
AutoCAD SHX Text
ALWAYS THINK
AutoCAD SHX Text
SAFETY
AutoCAD SHX Text
STANDARD DETAIL DRAWING NO.
AutoCAD SHX Text
UNITED STATES DEPARTMENT OF THE INTERIOR
AutoCAD SHX Text
BUREAU OF LAND MANAGEMENT
AutoCAD SHX Text
CORNER PANELS (WOOD)
AutoCAD SHX Text
REV. NO.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text 9/30/97
AutoCAD SHX Text
LJP
AutoCAD SHX Text
METRIC CONVERSION ADDED
AutoCAD SHX Text
BY OTHERS
AutoCAD SHX Text
AutoCAD SHX Text
N:\PROJECTS\STANDARD DRAWINGS\STDDWGS2009\02824-9.DWG
AutoCAD SHX Text 7/31/09
AutoCAD SHX Text
AutoCAD SHX Text
RTH
File details come from the government source that posted it. Updated .