This document is a set of Standard Operating Procedures (SOP) for the Shotgun Wastewater Treatment Plant, detailing operational protocols for wastewater systems. The procedures outline weekly system inspections, compliance requirements with the Shotgun Wastewater Permit and Recycled Water Use Plan, and daily operational data logging. Project requests can originate from various sources including District Engineering Team, Recreation Staff, Field Office Staff, or emergency situations.
The document also provides contracting guidelines, specifying that contracts with an Independent Government Estimate under $25,000 will be procured through district procurement, while contracts $25,000 or greater require State Office procurement with prior engineering review. The accompanying technical drawings include detailed schematics of the wastewater treatment infrastructure, specifically showing the chlorine contact tank details, site layout, and effluent disposal area with specifications for pipe systems, sprinkler heads, valves, and installation parameters.
View the file
Other files for this federal contract opportunity
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Standard Operating Procedures
Shotgun Wastewater Treatment Plant
This document describes procedures for wastewater systems operations Conduct weekly system inspections to identify repair or maintenance requirements.
All operations, maintenance, repairs and reporting will be in compliance with the current Shotgun Wastewater Permit and Recycled Water Use Plan.
Record daily operations data in the Shotgun Wastewater log.
Project requests may come from, hereafter referred to as project proponent;
o District Engineering Team o District Recreation Staff o Field Office Staff o Emergency Situations o Other
• Requests for service should include;
o Project Location o Description of project
• Once a project is identified and a request for service is received the assigned engineer or technician will work with the project proponent to develop a general statement of work and perform initial site investigations to determine existing conditions of the project
• District engineer will determine, based on workloads, timelines, and staff knowledge and experience, if design services will be performed in-house or by other means (i.e. Forest Service, A&E, etc.)
Contracting
• Contracts with an Independent Government Estimate of less than $25,000 will be procured through district procurement.
• Contracts with an Independent Government Estimate of greater than or equal to $25,000 will be procured through State Office procurement with prior State Office Engineering review.
References
• Recycled Water Use Plan S:\Engineering\Water Wastewater Reports\Shotgun WWTP
• Shotgun Wastewater Permit S:\Engineering\Water Wastewater Reports\Shotgun WWTP file://ilmoreu3ds1/eu/loc/Shared/Engineering/Water%20Wastewater%20Reports/Shotgun%20WWTP
-------:::::-.. ;:;;~_;;;,,;.;;;,:;:,~=-~-=-~--:---- i\ :, "i-1-ll 11'
II ',,
; 't"::.f~ f ·,,i:;; ·(!
G_
1,:1GA1...vsn.------
CHLORINE CONTACT
---~:~~~~;;~=~~~====~~~---------------------------------------------------------l'""'A"'WlNG'"''°='C"-·7
~ ~~·-~~~:::= I
DETAILS
c.o f\)
SHOTGUN PARK EFFLUENT DISPOSAL AREA
I I I I I I I I I I I I I I I I I I I I \ I
VALVE DRAIN VALVE .ck .. -~ ..
I I I I :q I
I I I I I
-:r 9 I I
I I I I I
SPRINKL R f ,\ HEADs, , r f SPRINKLE I I I I I I I I I I I I
I I I
I-:
z:
u.J :
I
__j I
LL_ :
LL_ :
u.J :
I I I I I I I I I I I I
I? V, t 9 '.,</( / . : q I .._ _, V,C-. 1 I --- --~ ,. I I 121' - - - - -c±:r ----~ -------- ------------
\ \Sc . ~ \ \ -1'v&s,.._ ~,.()<¢' ~ ¢ <,:1- , I I I I I I I I I
I
I I
S RiNkL R HEAD i I 1q
INKLER HEA
I I I I I
I I I I I I
I I
: q I I
-K
DRAIN VALV
OJ
0)
5' c\-\ \N
INSTALLED:
I I
I I
DRAIN
OJ
CO N
..p.. 0 co
"1
OJ
K-LINE 01410 POLY LOW DENSITY PIPE, 50mm 900 - ELEVATION
21 NELSON R2000WF ROTATOR SPRINKLER HEADS
(Adjusted to 45 psi max pressure, 40' apart)
TWO RAIN BIRD PESB-R SERIES SCRUBBER VALVES
(in center valve boxes, to alternate & regulate flow on sprinkler lines)
FOUR 1.5" GHEEN DRAIN VALVES (located at end of lines)
UNITED STATES DEPARTMENT OF THE INTERIOR
BUREAU OF LAND MANAGEMENT
EUGENE DISTRICT OFFICE
03/11