The project is the NIFC 440 Boise Air Center construction, with a solicitation number of 140L0624R0059. The federal agency involved is the Department of the Interior, Bureau of Land Management National Office. This drawing sheet provides the electrical legend, general notes, and abbreviations to be used throughout the construction drawings. It covers requirements such as compliance with the National Electric Code, working clearances, equipment mounting, and drawing scales. The drawing also includes various electrical symbols and abbreviations common to construction documents.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
J
S X
S S
M
T
PANEL
TX-XXX
100A4G
47,000 AIC X
M
XX
XXX
MTS-XX
XXX A
X
#X
OS
PS
D X#
M
H
EF-1
A
E102
E102
CIRCUIT BREAKER
CONTROL FUSE
FUSED SWITCH
SWITCH
PANELBOARD
MANUAL TRANSFER SWITCH
FEEDER DESIGNATION, SEE FEEDER SCHEDULE
TRANSFORMER
AVAILABLE FAULT CURRENT
MOTOR
DISCONNECT SWITCH
FUSED DISCONNECT SWITCH
MOTOR STARTER
COMBINATION MOTOR STARTER
DISTRIBUTION PANEL
NEW PANEL, SURFACE MOUNTED
METER
TRANSFORMER
GROUND TEST WELL
GROUND ROD
GROUNDING CONDUCTOR
GROUND BUS
BONDING POINT
ELECTRICAL GROUND
LED LUMINARIES
#=BRANCH CIRCUIT NUMBER
X=SWITCH LEG IDENTIFIER
SHADING INDICATES LUMINAIRE ON LIFE SAFETY
WALL MOUNTED LUMINAIRE
OCCUPANCY SENSOR
PHOTOCOLL FOR DAYLIGHTING
EXIT LIGHT (WITH FACES & DIRECTION ARROWS
INDICATED)
WALL MOUNTED EXIT LIGHT (WITH FACES &
DIRECTION ARROWS INDICATED)
WALL MOUNTED BATTERY PACK EMERGENCY LIGHT
2 PORT DATA FACEPLATE (TYPICAL) MOUNTED
AT +12 AFF.
CEILING MOUNTED SMOKE DETECTOR
P = PHOTOELECTRIC
T = THERMAL
MANUAL PULL STATION
FIRE ALARM HORN STROBE
KEY NOTE
EQUIPMENT TAG
HATCHING INDICATES ITEM(S) TO BE REMOVED
NORTH ARROW
DETAIL BUBBLE
DETAIL NUMBER
SHEET NO. - WHERE
DETAIL IS SHOWN
SECTION CUT
SECTION LETTER
SHEET NO. - WHERE
DETAIL IS SHOWN
BRANCH CIRCUIT HOME RUN TO PANELBOARD,
DESIGNATION INDICATES PANEL AND CIRCUIT
NUMBERS.
CONTROL WIRING
LIGHTING, ONE-LINE, AND POWER CIRCUITING
LIGHTING, ONE-LINE, AND POWER CIRCUITING
(UNDERGROUND)
CONDUIT BREAK SYMBOL
CONNECT NEW (SHADED SIDE) TO EXISTING
LIMIT OF DEMOLITION (SHADED SIDE AND HATCHED)
CONDUIT CAP
CONDUIT CHANGE IN ELEVATION (DROP)
CONDUIT STUB DOWN (OUT OF DRAWING LIMITS)
CONDUIT STUB UP (OUT OF DRAWING LIMITS)
JUNCTION BOX MOUNTED AT 100" AFF. FOR
FUTURE SECURITY SYSTEM. WITH 1" CONDUIT
AND PULL STRING.
SWITCH SYMBOL
SINGLE POLE (IF BLANK)
2=DOUBLE POLE
3=THREE-WAY
4=FOUR-WAY
D=DIMMER
K=KEY OPERATED
LV=LOW VOLTAGE
TO=THERMAL OVERLOAD
WP=WEATHERPROOF
X=SMALL LETTER INDICATES LUMINARIES
CONTROLLEDDUAL SWITCH
WELDER RECEPTACLE
SPECIAL PURPOSE RECEPTACLE
SPECIAL SYSTEMS SYMBOLS:
CR= CARD READER
OS= OCCUPANCY SENSOR
MISC. SYSTEM COMPONENT
PAC= PHYSICAL ACCESS CONTROL
ACC= ACCESS CONTROL CONSOLE
ANN= ANNUNCIATOR
CAM= CONTROL ADDRESSABLE MODULE
FACP= FIRE ALARM CONTROL PANEL
FSD= FIRE SMOKE DAMPER
MAM= MONITOR ADDRESSABLE MODULE
TVSS= TRANSIENT VOLTAGE SURGE
SUPPRESSER
VFD= VARIABLE FREQUENCY DRIVE QUADRIPLEX RECEPTACLE
DUPLEX RECEPTACLE
GFI= GROUND FAULT CIRCUIT
INTERRUPTER
D= DEDICATED GROUNDED
RECEPTACLE
IG= ISOLATED GROUND
WP= WEATHER PROOF
FLOOR MOUNTED DUPLEX RECEPTACLE
FLOOR MOUNTED QUADRIPLEX RECEPTACLE
FLOOR MOUNTED TELE/DATA RECEPTACLE
CEILING MOUNTED DUPLEX RECEPTACLE
CEILING MOUNTED QUADRIPLEX RECEPTACLE
SYMBOL DESCRIPTION SYMBOL DESCRIPTION
SYMBOL DESCRIPTION
SYMBOL DESCRIPTION
SYMBOL DESCRIPTION
SYMBOL DESCRIPTION
SYMBOL DESCRIPTION
-GRAPHIC SYMBOLS-
-TELECOM & FIRE ALARM DEVICES-
-LIGHTING-
-GROUNDING-
-POWER--ONE LINE SYMBOLS-
-GENERAL-
-ABBREVIATIONS-
(NOTE: NOT ALL SYMBOLS OR ABBREVIATIONS SHOWN ARE USED ON THESE DRAWINGS)ELECTRICAL LEGEND
PLAN
NORTH
CEILING MOUNTED DATA RECEPTACLE
2 PORT TELE/DATA FACEPLATE (TYPICAL) MOUNTED
AT +12 AFF.
WIRELESS ACCESS POINT
WAP
Project No.
LBYD FEDERAL, LLC
1425 Higham Street Idaho Falls, Idaho 83402
Phone (208) 528-8718
C copyright 2023
These drawings and design intent are the sole property of LBYD FEDERAL, LLC which may not be reproduced without written permission.
1 2 3 4 5
D
C
B
A
S h e e t
T it le
D e s ig n e d b y
D ra w n b y
C h e c k e d b y
A p p ro v e d b y
R e v is io n s
U n it e d S ta te s D e p a rt m e n t o f th e I n te ri o r
B u re a u o f L a n d M a n a g e m e n t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
070117.010
/1
/2
:0
:0
P
M Q
L B
Y D
F e d e ra l P ro je c t F ile s \0
-A c ti v e
P ro je c ts
\0 -A rc h iv e \0
.0
N
IF
C
-B o is e A ir C n tr
\0 D ra w in g s \R e v it \0
.0
E -R
.r v t
E L E
C T
R
IC
A L
L E
G E
N D
N
O T
E S
A N
D A
B B
R E
V
IA
T
IO
N S
D S
IM
S
D S
IM
S
M H
A D
D A
D
B C
A R
T E
R
N
IF
C
B O
IS
E
A
IR
C E
N T
E R
S
IT
E A
N D
B U
IL
D
IN
G
D E
S
IG
N
W C
O M
M E
R C
E A
V E
B
O
IS
E
ID
A H
O
140L0623F0109
070117.010
8/19/2024
E-001
N A
T
IO
N A
L I N
T E
R A
G E
N C
Y F
IR
E
C E
N T
E R
136 153
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
1. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH
LOCAL BUILDING CODES AND THE LATEST EDITION OF
THE NATIONAL ELECTRIC CODE (NEC).
2. REFERENCE SPECIFICATIONS FOR CONSTRUCTION
MATERIALS AND INSTALLATION PROCEDURES.
SPECIFICATIONS ARE A PART OF THE CONSTRUCTION
DOCUMENTS. SHOULD ANY CONFLICT ARISE BETWEEN
THE DRAWINGS AND SPECIFICATIONS, SUCH CONFLICT
SHALL BE BROUGHT TO THE ATTENTION OF THE
GOVERNMENT FOR RESOLUTION.
3. THESE DRAWINGS ARE DIAGRAMMATIC IN CHARACTER
AND DO NOT NECESSARILY SHOW MATERIALS FOR A
COMPLETE INSTALLATION.
4. ALL PENETRATIONS THROUGH FIRE SEPARATION WALLS
SHALL BE SEALED TO MAINTAIN SEPARATION RATING.
5. PENETRATIONS THROUGH SECURITY RATED WALLS AND
FLOORS SHALL BE PROTECTED PER PROJECT
REQUIREMENTS.
6. JUNCTION BOXES FOR LUMINARIES ARE NOT INDICATED
HERE ON. PROVIDE THE PROPER NUMBER OF J-BOXES TO
MEET LOCAL CODE AND NATIONAL ELECTRICAL CODE.
7. LIGHT SWITCHES SHALL BE MOUNTED 48 INCHES ABOVE
FINISHED FLOOR TO CENTERLINE OF DEVICE, UNLESS
OTHERWISE NOTED.
8. RECEPTACLES SHALL BE LOCATED 18 INCHES ABOVE THE
FINISHED FLOOR TO CENTERLINE OF THE DEVICE,
UNLESS OTHERWISE NOTED. ABOVE COUNTER
RECEPTACLES SHALL BE MOUNTED 6 INCHES ABOVE THE
BACK SPLASH TO THE CENTERLINE OF THE DEVICE.
9. WORKING CLEARANCES FOR ELECTRICAL EQUIPMENT
SHALL BE IN COMPLIANCE WITH NEC.
10. PANELBOARD OR SWITCHBOARD DEDICATED SPACE
FROM FLOOR TO STRUCTURAL CEILING SHALL BE CLEAR
OF PIPING, DUCTS, EQUIPMENT, ETC. NOT ASSOCIATED
WITH THE IMMEDIATE EQUIPMENT IN ACCORDANCE WITH
NEC 408.
11. ALL EQUIPMENT MOUNTED OVERHEAD OR ABOVE
SUSPENDED CEILINGS WEIGHING 30 POUNDS OR MORE
SHALL BE SECURED TO A PERMANENT STRUCTURE BY
MEANS OF HAVING SUFFICIENT CAPACITY TO RESIST
HORIZONTAL FORCES OF 0.5 TIMES THE EQUIPMENT
WEIGHT AND VERTICAL FORCES OF 1.5 TIMES THE
EQUIPMENT WEIGHT.
12. DRAWINGS ARE PRINTED IN ANSI D SIZE. IF DRAWINGS
ARE NOT 22" X 34", USE SCALES ACCORDINGLY.
GENERAL SHEET NOTES
(E) EXISTING
(N) NEW
(PART) (PARTIAL CIRCUIT)
+XX MOUNTING HEIGHT IN INCHES
AFF UNO
A AMP
AC ABOVE COUNTER TOP
AF AMP FRAME
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITY HAVING
JURISDICTION
AIC AMPS INTERRUPTING CAPACITY
AS AMPS SENSOR
AT AMP TRIP
BFG BELOW FINISHED GRADE
C CONDUIT
CAM CONTROL ADDRESSBLE
MODULE
CB MOLDED CASE CIRCUIT
BREAKER
CKT CIRCUIT
CLG CEILING
CONT CONTINUED
CSC CEILING SECURITY CAMERA
EF EXHAUST FAN
EBG ELECTRICAL GROUND BUSBAR
ELEC ELECTRIC
ELEV ELEVATION
EMERG EMERGENCY
FA FIRE ALARM
FACP FIRE ALARM CONTROL PANEL
FLR FLOOR
G GROUND (EQUIPMENT)
GEN GENERATOR
GFCI GROUND FAULT CIRCUIT
INTERRUPTER
GFI GROUND FAULT CIRCUIT
INTERRUPTER
GND GROUND (EQUIPMENT)
HP HORSEPOWER
HV HIGH VOLTAGE
IC INTERRUPTING CAPACITY
IG ISOLATED GROUND
JB JUNCITON BOX
K THOUSAND
LTG LIGHTING
LTS LIGHTS
LV LOW VOLTAGE
MAM MONITOR ADDRESSABLE
MODULE
MCB MAIN CIRCUIT BREAKER
MCM THOUSAND CIRCULAR MILS
MCSW MOLDED CASE SWITCH
MLO MAIN LUGS ONLY
MTD MOUNTED
MTS MANUAL TRANSFER SWITCH
N NEUTRAL
NC NORMALLY CLOSED
NEC NATIONAL ELECTRIC CODE
NF NON FUSED
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NO NORMALLY OPEN
P POLE
PB PULL BOX
PNL PANEL
PWR POWER
RCPT RECEPTACLE(S)
SBC STRANDED BARE COPPER
SDBTC SOFT DRAWN BARE COPPER
SP SPARE
SW SWITCH
T TRANSFORMER
TV TELEVISION
TVSS TRANSIENT VOLTAGE SURGE
SUPPRESSOR
TYP TYPICAL
UF UNDERFLOOR
UG UNDERGROUND
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER
SUPPLY
V VOLTAGE
VFD VARIABLE FREQUENCY DRIVE
WG WIRE GUARD
WP WEATHERPROOF
WSC WALL MOUNT SECURITY
CAMERA
XFMR TRANSFORMER
D es cr ip tio n D at e
0%
IS
S U
E D
F O
R C
O N
S T
R U
C T
IO
N
5/
/2
R
E V
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N 8/
/2
P R
O
FE
SSIONA L ENGINEER
MARIO A L HA DDAD
STATE OF IDAHO
L I C E N S E D
2061470