Att16_Revised_Sheet_E-001_0001.pdf

PDF 1009 KB Posted

Attached to
NIFC 440 BOISE AIR CENTER CONSTRUCTION
Solicitation number
140L0624R0059
Issued by

About this file

This document appears to be an Electrical Legend, Notes, and Abbreviations sheet for a federal construction project. The key details are:

The project is the NIFC 440 Boise Air Center construction, with a solicitation number of 140L0624R0059. The federal agency involved is the Department of the Interior, Bureau of Land Management National Office. This drawing sheet provides the electrical legend, general notes, and abbreviations to be used throughout the construction drawings. It covers requirements such as compliance with the National Electric Code, working clearances, equipment mounting, and drawing scales. The drawing also includes various electrical symbols and abbreviations common to construction documents.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

J

S X

S S

M

T

PANEL

TX-XXX

100A4G

47,000 AIC X

M

XX

XXX

MTS-XX

XXX A

X

#X

OS

PS

D X#

M

H

EF-1

A

E102

E102

CIRCUIT BREAKER

CONTROL FUSE

FUSED SWITCH

SWITCH

PANELBOARD

MANUAL TRANSFER SWITCH

FEEDER DESIGNATION, SEE FEEDER SCHEDULE

TRANSFORMER

AVAILABLE FAULT CURRENT

MOTOR

DISCONNECT SWITCH

FUSED DISCONNECT SWITCH

MOTOR STARTER

COMBINATION MOTOR STARTER

DISTRIBUTION PANEL

NEW PANEL, SURFACE MOUNTED

METER

TRANSFORMER

GROUND TEST WELL

GROUND ROD

GROUNDING CONDUCTOR

GROUND BUS

BONDING POINT

ELECTRICAL GROUND

LED LUMINARIES

#=BRANCH CIRCUIT NUMBER

X=SWITCH LEG IDENTIFIER

SHADING INDICATES LUMINAIRE ON LIFE SAFETY

WALL MOUNTED LUMINAIRE

OCCUPANCY SENSOR

PHOTOCOLL FOR DAYLIGHTING

EXIT LIGHT (WITH FACES & DIRECTION ARROWS

INDICATED)

WALL MOUNTED EXIT LIGHT (WITH FACES &

DIRECTION ARROWS INDICATED)

WALL MOUNTED BATTERY PACK EMERGENCY LIGHT

2 PORT DATA FACEPLATE (TYPICAL) MOUNTED

AT +12 AFF.

CEILING MOUNTED SMOKE DETECTOR

P = PHOTOELECTRIC

T = THERMAL

MANUAL PULL STATION

FIRE ALARM HORN STROBE

KEY NOTE

EQUIPMENT TAG

HATCHING INDICATES ITEM(S) TO BE REMOVED

NORTH ARROW

DETAIL BUBBLE

DETAIL NUMBER

SHEET NO. - WHERE

DETAIL IS SHOWN

SECTION CUT

SECTION LETTER

SHEET NO. - WHERE

DETAIL IS SHOWN

BRANCH CIRCUIT HOME RUN TO PANELBOARD,

DESIGNATION INDICATES PANEL AND CIRCUIT

NUMBERS.

CONTROL WIRING

LIGHTING, ONE-LINE, AND POWER CIRCUITING

LIGHTING, ONE-LINE, AND POWER CIRCUITING

(UNDERGROUND)

CONDUIT BREAK SYMBOL

CONNECT NEW (SHADED SIDE) TO EXISTING

LIMIT OF DEMOLITION (SHADED SIDE AND HATCHED)

CONDUIT CAP

CONDUIT CHANGE IN ELEVATION (DROP)

CONDUIT STUB DOWN (OUT OF DRAWING LIMITS)

CONDUIT STUB UP (OUT OF DRAWING LIMITS)

JUNCTION BOX MOUNTED AT 100" AFF. FOR

FUTURE SECURITY SYSTEM. WITH 1" CONDUIT

AND PULL STRING.

SWITCH SYMBOL

SINGLE POLE (IF BLANK)

2=DOUBLE POLE

3=THREE-WAY

4=FOUR-WAY

D=DIMMER

K=KEY OPERATED

LV=LOW VOLTAGE

TO=THERMAL OVERLOAD

WP=WEATHERPROOF

X=SMALL LETTER INDICATES LUMINARIES

CONTROLLEDDUAL SWITCH

WELDER RECEPTACLE

SPECIAL PURPOSE RECEPTACLE

SPECIAL SYSTEMS SYMBOLS:

CR= CARD READER

OS= OCCUPANCY SENSOR

MISC. SYSTEM COMPONENT

PAC= PHYSICAL ACCESS CONTROL

ACC= ACCESS CONTROL CONSOLE

ANN= ANNUNCIATOR

CAM= CONTROL ADDRESSABLE MODULE

FACP= FIRE ALARM CONTROL PANEL

FSD= FIRE SMOKE DAMPER

MAM= MONITOR ADDRESSABLE MODULE

TVSS= TRANSIENT VOLTAGE SURGE

SUPPRESSER

VFD= VARIABLE FREQUENCY DRIVE QUADRIPLEX RECEPTACLE

DUPLEX RECEPTACLE

GFI= GROUND FAULT CIRCUIT

INTERRUPTER

D= DEDICATED GROUNDED

RECEPTACLE

IG= ISOLATED GROUND

WP= WEATHER PROOF

FLOOR MOUNTED DUPLEX RECEPTACLE

FLOOR MOUNTED QUADRIPLEX RECEPTACLE

FLOOR MOUNTED TELE/DATA RECEPTACLE

CEILING MOUNTED DUPLEX RECEPTACLE

CEILING MOUNTED QUADRIPLEX RECEPTACLE

SYMBOL DESCRIPTION SYMBOL DESCRIPTION

SYMBOL DESCRIPTION

SYMBOL DESCRIPTION

SYMBOL DESCRIPTION

SYMBOL DESCRIPTION

SYMBOL DESCRIPTION

-GRAPHIC SYMBOLS-

-TELECOM & FIRE ALARM DEVICES-

-LIGHTING-

-GROUNDING-

-POWER--ONE LINE SYMBOLS-

-GENERAL-

-ABBREVIATIONS-

(NOTE: NOT ALL SYMBOLS OR ABBREVIATIONS SHOWN ARE USED ON THESE DRAWINGS)ELECTRICAL LEGEND

PLAN

NORTH

CEILING MOUNTED DATA RECEPTACLE

2 PORT TELE/DATA FACEPLATE (TYPICAL) MOUNTED

AT +12 AFF.

WIRELESS ACCESS POINT

WAP

Project No.

LBYD FEDERAL, LLC

1425 Higham Street Idaho Falls, Idaho 83402

Phone (208) 528-8718

C copyright 2023

These drawings and design intent are the sole property of LBYD FEDERAL, LLC which may not be reproduced without written permission.

1 2 3 4 5

D

C

B

A

S h e e t

T it le

D e s ig n e d b y

D ra w n b y

C h e c k e d b y

A p p ro v e d b y

R e v is io n s

U n it e d S ta te s D e p a rt m e n t o f th e I n te ri o r

B u re a u o f L a n d M a n a g e m e n t

BLM Project #

Project #

Date:

ALWAYS THINK SAFETY Sheet of

070117.010

/1

/2

:0

:0

P

M Q

L B

Y D

F e d e ra l P ro je c t F ile s \0

-A c ti v e

P ro je c ts

\0 -A rc h iv e \0

.0

N

IF

C

-B o is e A ir C n tr

\0 D ra w in g s \R e v it \0

.0

E -R

.r v t

E L E

C T

R

IC

A L

L E

G E

N D

N

O T

E S

A N

D A

B B

R E

V

IA

T

IO

N S

D S

IM

S

D S

IM

S

M H

A D

D A

D

B C

A R

T E

R

N

IF

C

B O

IS

E

A

IR

C E

N T

E R

S

IT

E A

N D

B U

IL

D

IN

G

D E

S

IG

N

W C

O M

M E

R C

E A

V E

B

O

IS

E

ID

A H

O

140L0623F0109

070117.010

8/19/2024

E-001

N A

T

IO

N A

L I N

T E

R A

G E

N C

Y F

IR

E

C E

N T

E R

136 153

IS

S

U E

D F

O R

C O

N S

T R

U C

T

IO

N

1. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH

LOCAL BUILDING CODES AND THE LATEST EDITION OF

THE NATIONAL ELECTRIC CODE (NEC).

2. REFERENCE SPECIFICATIONS FOR CONSTRUCTION

MATERIALS AND INSTALLATION PROCEDURES.

SPECIFICATIONS ARE A PART OF THE CONSTRUCTION

DOCUMENTS. SHOULD ANY CONFLICT ARISE BETWEEN

THE DRAWINGS AND SPECIFICATIONS, SUCH CONFLICT

SHALL BE BROUGHT TO THE ATTENTION OF THE

GOVERNMENT FOR RESOLUTION.

3. THESE DRAWINGS ARE DIAGRAMMATIC IN CHARACTER

AND DO NOT NECESSARILY SHOW MATERIALS FOR A

COMPLETE INSTALLATION.

4. ALL PENETRATIONS THROUGH FIRE SEPARATION WALLS

SHALL BE SEALED TO MAINTAIN SEPARATION RATING.

5. PENETRATIONS THROUGH SECURITY RATED WALLS AND

FLOORS SHALL BE PROTECTED PER PROJECT

REQUIREMENTS.

6. JUNCTION BOXES FOR LUMINARIES ARE NOT INDICATED

HERE ON. PROVIDE THE PROPER NUMBER OF J-BOXES TO

MEET LOCAL CODE AND NATIONAL ELECTRICAL CODE.

7. LIGHT SWITCHES SHALL BE MOUNTED 48 INCHES ABOVE

FINISHED FLOOR TO CENTERLINE OF DEVICE, UNLESS

OTHERWISE NOTED.

8. RECEPTACLES SHALL BE LOCATED 18 INCHES ABOVE THE

FINISHED FLOOR TO CENTERLINE OF THE DEVICE,

UNLESS OTHERWISE NOTED. ABOVE COUNTER

RECEPTACLES SHALL BE MOUNTED 6 INCHES ABOVE THE

BACK SPLASH TO THE CENTERLINE OF THE DEVICE.

9. WORKING CLEARANCES FOR ELECTRICAL EQUIPMENT

SHALL BE IN COMPLIANCE WITH NEC.

10. PANELBOARD OR SWITCHBOARD DEDICATED SPACE

FROM FLOOR TO STRUCTURAL CEILING SHALL BE CLEAR

OF PIPING, DUCTS, EQUIPMENT, ETC. NOT ASSOCIATED

WITH THE IMMEDIATE EQUIPMENT IN ACCORDANCE WITH

NEC 408.

11. ALL EQUIPMENT MOUNTED OVERHEAD OR ABOVE

SUSPENDED CEILINGS WEIGHING 30 POUNDS OR MORE

SHALL BE SECURED TO A PERMANENT STRUCTURE BY

MEANS OF HAVING SUFFICIENT CAPACITY TO RESIST

HORIZONTAL FORCES OF 0.5 TIMES THE EQUIPMENT

WEIGHT AND VERTICAL FORCES OF 1.5 TIMES THE

EQUIPMENT WEIGHT.

12. DRAWINGS ARE PRINTED IN ANSI D SIZE. IF DRAWINGS

ARE NOT 22" X 34", USE SCALES ACCORDINGLY.

GENERAL SHEET NOTES

(E) EXISTING

(N) NEW

(PART) (PARTIAL CIRCUIT)

+XX MOUNTING HEIGHT IN INCHES

AFF UNO

A AMP

AC ABOVE COUNTER TOP

AF AMP FRAME

AFC ABOVE FINISHED COUNTER

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AHJ AUTHORITY HAVING

JURISDICTION

AIC AMPS INTERRUPTING CAPACITY

AS AMPS SENSOR

AT AMP TRIP

BFG BELOW FINISHED GRADE

C CONDUIT

CAM CONTROL ADDRESSBLE

MODULE

CB MOLDED CASE CIRCUIT

BREAKER

CKT CIRCUIT

CLG CEILING

CONT CONTINUED

CSC CEILING SECURITY CAMERA

EF EXHAUST FAN

EBG ELECTRICAL GROUND BUSBAR

ELEC ELECTRIC

ELEV ELEVATION

EMERG EMERGENCY

FA FIRE ALARM

FACP FIRE ALARM CONTROL PANEL

FLR FLOOR

G GROUND (EQUIPMENT)

GEN GENERATOR

GFCI GROUND FAULT CIRCUIT

INTERRUPTER

GFI GROUND FAULT CIRCUIT

INTERRUPTER

GND GROUND (EQUIPMENT)

HP HORSEPOWER

HV HIGH VOLTAGE

IC INTERRUPTING CAPACITY

IG ISOLATED GROUND

JB JUNCITON BOX

K THOUSAND

LTG LIGHTING

LTS LIGHTS

LV LOW VOLTAGE

MAM MONITOR ADDRESSABLE

MODULE

MCB MAIN CIRCUIT BREAKER

MCM THOUSAND CIRCULAR MILS

MCSW MOLDED CASE SWITCH

MLO MAIN LUGS ONLY

MTD MOUNTED

MTS MANUAL TRANSFER SWITCH

N NEUTRAL

NC NORMALLY CLOSED

NEC NATIONAL ELECTRIC CODE

NF NON FUSED

NIC NOT IN CONTRACT

NL NIGHT LIGHT

NO NORMALLY OPEN

P POLE

PB PULL BOX

PNL PANEL

PWR POWER

RCPT RECEPTACLE(S)

SBC STRANDED BARE COPPER

SDBTC SOFT DRAWN BARE COPPER

SP SPARE

SW SWITCH

T TRANSFORMER

TV TELEVISION

TVSS TRANSIENT VOLTAGE SURGE

SUPPRESSOR

TYP TYPICAL

UF UNDERFLOOR

UG UNDERGROUND

UNO UNLESS NOTED OTHERWISE

UPS UNINTERRUPTIBLE POWER

SUPPLY

V VOLTAGE

VFD VARIABLE FREQUENCY DRIVE

WG WIRE GUARD

WP WEATHERPROOF

WSC WALL MOUNT SECURITY

CAMERA

XFMR TRANSFORMER

D es cr ip tio n D at e

0%

IS

S U

E D

F O

R C

O N

S T

R U

C T

IO

N

5/

/2

R

E V

IS

S

U E

D F

O R

C O

N S

T R

U C

T

IO

N 8/

/2

P R

O

FE

SSIONA L ENGINEER

MARIO A L HA DDAD

STATE OF IDAHO

L I C E N S E D

2061470

Sheets
E-001 - ELECTRICAL LEGEND, NOTES AND ABBREVIATIONS
2024-08-19T15:34:45-0700
Mario Al Haddad
I have reviewed this document

File details come from the government source that posted it. Updated .