Attachment_B_Drawings.pdf
PDF 6 MB Posted
- Attached to
- FISH HOLDING CONSTRUCTION & UPGRADES Federal contract opportunity
- Solicitation number
- 140G0118R0016
About this file
Attachment B Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment_K_Design_Addenda_1.pdf | ||
| Attachment_F_Interested_Parties_List.042718.xlsx | XLSX spreadsheet | |
| Sol_140G0118R0016_Amd_0002.pdf | ||
| Attachment_J_Questions.Responses.docx | DOCX document | |
| Attachment_G.1_Photo.pdf | ||
| Attachment_G.3_Photo.pdf | ||
| Attachment_G.2_Photo.pdf | ||
| Attachment_H_As_Built_Piping.pdf | ||
| Attachment_I_Questions.Responses.docx | DOCX document | |
| Sol_140G0118R0016_Amd_0001.pdf | ||
| Attachment_F_Interested_Parties_List.032718.xlsx | XLSX spreadsheet | |
| Attachment_F_Interested_Parties_List.xlsx | XLSX spreadsheet | |
| Attachment_A_Specifications.pdf | ||
| Attachment_D_Release_of_Claims.doc | DOC document | |
| Attachment_C_Wage_Decision_WI3.pdf | ||
| Sol_140G0118R0016.pdf |
Show all 16
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Consultants Structural
Plumbing & Electrical
GRAEF
One Honey Creek Corporate Center 125 South 84th St, Suite 401 Milwaukee, WI 53214-1469 Office: 414.259.1500
Strategic Structural Design, LLC 725 Heartland Trail, Suite 203 Madison, WI 53711 Office: 608.841.1850
EARTH
CONCRETE/PRECAST CONC.
CONCRETE MASONRY UNIT
FACE BRICK
STONE
STRUCTURAL STEEL
BATT INSULATION
DIMENSIONAL LUMBER
RIGID INSULATION
GYPSUM BOARD
PLYWOOD
Material Symbols
EXISTING WALL
Room name
A101
A101
ROOM TAG
SECTION CUT
ELEVATION
DETAIL INDICATOR
DOOR NUMBER
A1 WALL TYPE
VERTICAL WORKING
POINT ELEVATION
REVISION INDICATOR
GRID LINE MARKER
Graphic Symbols
A101
T/ SLAB
100'-0"
AD AREA DRAIN
AFF ABOVE FINISHED FLOOR
ACT ACOUSTICAL CEILING TILE
ADJ ADJUSTABLE
ALT ALTERNATE
ALUM ALUMINUM
@ AT
BRG BEARING
BIT BITUMINOUS
BLK'G BLOCKING
BR BRICK
BLDG BUILDING
CAB CABINET
CPT CARPET
CLG CEILING
CT CERAMIC TILE
COL COLUMN
CONC CONCRETE
CB CONCRETE BLOCK
CMU CONCRETE MASONRY UNIT
CONT CONTINUOUS
CONTR CONTRACTOR
CJ CONTROL JOINT
COORD COORDINATE
DIA DIAMETER
DRS DOORS
DS DOWNSPOUT
EWC ELECTRIC WATER CHILLER
ELECT ELECTRICAL
EL ELEVATION
ELEV ELEVATOR
EP EPOXY PAINT
EQUIP EQUIPMENT
EXIST EXISTING
EPS EXPANDED POLYSTYRENE
EXP EXPOSED
EXT EXTERIOR
EIFS EXTERIOR INSULATION FINISH SYSTEM
FV FIELD VERIFY
FIN FINISH
FE FIRE EXTINGUISHER
FL FLOOR
FD FLOOR DRAIN
FTG FOOTING
FDN FOUNDATION
GEN GENERAL
GC GENERAL CONTRACTOR
GL GLASS OR GLAZING
GFCMU GROUND FACE CMU
GYP BD GYPSUM BOARD
H&V HEATING & VENTILATION
HC HOLLOW CORE
HM HOLLOW METAL
HO HOLD OPEN ARM
HR HOURS
HYD HYDRANT
INSUL INSULATION
INT INTERIOR
JT JOINT
JST JOIST
Typical Abbreviations List
MBD MARKER BOARD
MAS MASONRY
MO MASONRY OPENING
MAX MAXIMUM
MECH MECHANICAL
MTL METAL
MIN MINIMUM
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OH OVERHEAD
PNT PAINT
PLAS PLASTER
PLAM PLASTIC LAMINATE
PL PLATE
PLBG PLUMBING
PLYWD PLYWOOD
PCT PORCELAIN CERAMIC TILE
P/C PRECAST
P/C TERR PRECAST TERRAZZO
PREFAB PREFABRICATED
PREFIN PREFINISHED
PT PRESSURE TREATED
QT QUARRY TILE
REINF REINFORCEMENT
REQ'D REQUIRED
R RISERS
RD ROOF DRAIN
RFG ROOFING
RFS ROOM FINISH SCHEDULE
RM ROOM
SCHED SCHEDULE
S SEALED
SIM SIMILAR
SC SOLID CORE
S.SURF SOLID SURFACE
SPEC SPECIFICATION
ST STAIN
SS STAINLESS STEEL
STRUCT STRUCTURE OR STRUCTURAL
TBD TACKBOARD
TEMP TEMPERED
TERR T TERRAZZO TILE
T&G TONGUE & GROOVE
T/ TOP OF
TP TOILET PARTITION
TR TREADS
TYP TYPICAL
UNFIN UNFINISHED
VB VAPOR BARRIER
VERT VERTICALLY
VCT VINYL COMPOSITION TILE
VWC VINYL WALL COVERING
VB VINYL BASE
WWF WELDED WIRE FABRIC
WDW WINDOW
W/ WITH
WD WOOD
LA CROSSE
ONALASKA
I-90
UMESC SITE
LOCATION
LA CROSSE
AIRPORT
LA CROSSE
54603
STATE OF WISCONSIN MAP
N . T hi rd
S tre et
L a
C ro ss e, W I
(6
) 7
-2
Ph (6
) 7
-2
Fa x
AR
CH
IT
EC
TS
IN
C
Scale:
SHEET NO.
SHEET TITLE
NO.
REVISIONS
SET TYPE:
DRAWN BY:
DRAWING DATE:
PROJECT NO:
DATE
COPYRIGHT C 2012 VANTAGE ARCHITECTS, INC.
PR
O
JE
C
T
TI
TL
E:
PR
O
JE
C
T
LO
C
AT
IO
N
A
R C
H I T
E C
T S
I N C
N . T hi rd
S
C ro ss e, W
I 5
Ph on e
(6
) 7
-2
Fa x
(6
) 7
-2
F an ta R ee d
R oa d La
C ro ss e, W is co ns in
As indicated
G000
COVER SHEET
BID
DOCUMENTS
BG/SDM
02/03/2017
0319.14
U pp er M id w es t E nv iro nm en ta l S ci en ce s
C en te r
Fi sh
H ol di ng
R en ov at io n
GENERAL
G000 COVER SHEET
CIVIL
C100 SITE PLAN
ARCHITECTURAL
A100 DEMOLITION PLAN
A101 INTERIOR FINISHES PLAN & SCHEDULES
A102 SLAB CUTTING PLAN
A103 TRENCH LAYOUT PLAN
STRUCTURAL
S001 STRUCTURAL GENERAL NOTES
S101 FOUNDATION PLAN
PLUMBING
P001 PLUMBING SYMBOLS, SCHEDULES, AND
ABBREVIATIONS
P101 PLUMBING DEMOLITION PLANS
P102 PLUMBING PLANS
P501 PLUMBING DETAILS
P502 PLUMBING DETAILS
ELECTRICAL
E001 ELECTRICAL SYMBOLS, ABBREVIATIONS,
AND SHEET INDEX
E101 ELECTRICAL DEMOLITION PLAN
E102 ELECTRICAL PLAN
E501 ELECTRICAL DETAILS & DIAGRAMS
E502 ELECTRICAL SCHEDULES
Sheet Index Project Location
Upper Midwest Environmental Sciences Center Fish Holding Renovation 2630 Fanta Reed Road La Crosse, Wisconsin 54603
750 North Third Street Suite F La Crosse, WI 54601 Phone: (608) 784-2729
BUILDING 'C'
'G' BUILDING
HEATEDSTORAGE
LOWER LEVEL FFE = 651.0
UPPER LEVEL FFE = 655.0
FH
EXISTING ASPHALTBUILDING 'D'
EXISTING TELEPHONE PEDESTAL
BUILDING 'B'
BUILDING 'A'
CHEMICALSTORAGEBUNKER
S
S
S
W
W
W
G G
G
G
W
C
C
C
SOUTH PARKING LOT
(ASPHALT)
PARKING LOT
VISITOR
PARKING
GEN.BUILDING
FISH
HOLDING S
FH
ST ST
ST
(LOWER LEVEL)
PROJECT LIMIT
ENTRY
MH
E
VEHICLE ACCESS ROUTE
EXISTING WATER SERVICEW
EXISTING WASTE WATER PIPINGS
MANHOLE
MH
FH
FIRE HYDRANT
UNDERGROUND ELECTRICE
SITE UTILITY SYMBOLS
N . T hi rd
S
C ro ss e, W I
(6
) 7
-2
Ph (6
) 7
-2
Fa x
AR
CH
IT
EC
TS
IN
C
Scale:
SHEET NO.
SHEET TITLE
NO.
REVISIONS
SET TYPE:
DRAWN BY:
DRAWING DATE:
PROJECT NO:
DATE
COPYRIGHT C 2012 VANTAGE ARCHITECTS, INC.
PR
O
JE
C
T
TI
TL
E:
PR
O
JE
C
T
LO
C
AT
IO
N
A
R C
H I T
E C
T S
I N C
N . T hi rd
S
C ro ss e, W
I 5
Ph on e
(6
) 7
-2
(6
) 7
-2
F an ta R ee d
R oa d La
C ro ss e, W is co ns in
As indicated
C100
SITE PLAN
BID
DOCUMENTS
BG/SDM
02/03/2017
0319.14
U pp er M id w es t E nv iro nm en ta l S ci en ce s
C en te r
Fi sh
H ol di ng
R en ov at io n
1" = 40'-0"2 SITE PLAN
NORTH
SITE PLAN KEY NOTES
MARK DESCRIPTION
1 EXISTING PAVED SURFACE TO REMAIN. AREAS DAMAGED BY THIS
PROJECT SHALL BE PATCHED AND REPAIRED BY THE
CONTRACTOR.
2 BUILDING ACCESS (FISH HOLDING AREA) THRU EXISTING
OVERHEAD SECTIONAL DOOR.
3 LOCATE AREA FOR TEMPORARY STOCKPILING OF DEMOLISHED
MATERIALS. VERIFY EXACT LOCATION WITH OWNER.
4 EXISTING CONCRETE WALKWAYS AND LAWN AREA TO REMAIN. IF
EXCAVATION IS REQUIRED IN THIS AREA, THE CONTRACTOR
SHALL VERIFY ALL UNDERGROUND UTILITIES PRIOR TO
COMMENCING WITH ANY EXCAVATION.
5 EXISTING AUXILLARY WATER SERVICE ENTERING NORTH WALL OF
FISH HOLDING.
ELECTRICAL
C104-a
ELEV. EQUIP
WET LAB
C104-b
ELEC.
C108
WET LAB
C104-c
OFFICE
CORRIDOR
OFFICE
C104-d
JAN. 29
LAB
C104-e
OFFICE 22
LAB
C104-f
R1
R2
R3
R4
R5
R6
R7
R8
R9
R10
R11
R12
R13
R14
R15
R16
R17
R18
R19
R20
R21
R22
R23
R24
R25
R26
R27
R28
R29
R30
R31
R32
R33
R34
R35
R36
R37
R38
R39
EXISTING TRANSFORMER
GENERATOR
BUILDING
LAWN
AREA
C104-e
C104-d
C104.1
C104-c
C104-b
C104-a
D2
D2
D2
D2
D2
D3
D1
D1
D1
FISH HOLDING
C104
C
.2
D4
COL.
COL.
COL.
COL.
COL.
COL.
D6
D6 D6
D6D6
D6
D5
AHU
(ABOVE)
CONCRETE
LANDSCAPING
CURB
LIMIT OF WORK
INDICATED BY
DASHED LINE
D1
OH-1
D7
LIMIT OF WORK
D4
FH
MH
DEMOLITION GENERAL NOTES
THIS DEMOLITION PLAN DOES NOT PURPORT TO SHOW EVERY EXISTING
CONDITION OR ITEM THAT WILL BE NECESSARY AS PART OF THE
DEMOLITION WORK. THE CONTRACTOR SHALL EXAMINE ALL DRAWINGS
TO DETERMINE SCOPE OF DEMOLITION WORK REQUIRED TO COMPLETE
THE REMODELING WORK INDICATED ON THE DRAWINGS.
ALL FISH TANKS TO BE DISCONNECTED AND REMOVED BY UMESC
PERSONNEL.
SAW CUTTING OF EXISTING CONCRETE FLOOR SLAB TO BE PERFORMED
BY THE CONTRACTOR. SEE FLOOR SLAB SAW CUTTING PLAN ON SHEET
A/102.
ALL CORING THRU EXISTING WALLS & CEILINGS SHALL BE PERFORMED
BY THE CONTRACTOR REQUIRING THE SAME. EXISTING ROOF STRUCTURE
CONSISTS OF CAST-IN-PLACE CONCRETE.
ALL ADJACENT SURFACES DAMAGED BY DEMOLITION WORK SHALL BE
RESTORED TO EXISTING CONDITION.
VERIFY WITH OWNER FOR ITEMS TO BE SALVAGED BEFORE STARTING
DEMOLITION WORK.
IT IS INTENDED THAT THE FISH HOLDING TANKS BE DISCONNECTED AND
REMOVED BY UMESC PERSONEL IN PHASES. EACH PHASE SHALL BE RE-
CONNECTED AND MADE ACTIVE BEFORE THE NEXT BEGINS, AS FOLLOWS:
-PHASE 1 TANKS R1-5, 11-15, 21-25
-PHASE 2 TANKS R6-10. 16- 20 + ROUNDS AND SQUARES
-PHASE 3 TANKS R27-R39
CONSTRUCT DUST PROOF PARTITIONS TO SEPARATE AREAS OF
CONSTRUCTION. REFER TO SHEET A101 FOR PHASED WORK.
PRIOR TO BIDDING CONTRACTOR SHALL VISIT THE SITE TO VERIFY
EXISTING CONDITIONS, DIMENSIONS, PRODUCTS TO BE USED AND
QUANTITIES REQUIRED.
COORDINATE REMOVAL OF EXISTING DOORS, FRAMES AND HARDWARE
WITH OWNER. SALVAGE OR REMOVE AS DIRECTED.
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
N . T hi rd
S
C ro ss e, W I
(6
) 7
-2
Ph (6
) 7
-2
Fa x
AR
CH
IT
EC
TS
IN
C
Scale:
SHEET NO.
SHEET TITLE
NO.
REVISIONS
SET TYPE:
DRAWN BY:
DRAWING DATE:
PROJECT NO:
DATE
COPYRIGHT C 2012 VANTAGE ARCHITECTS, INC.
PR
O
JE
C
T
TI
TL
E:
PR
O
JE
C
T
LO
C
AT
IO
N
A
R C
H I T
E C
T S
I N C
N . T hi rd
S
C ro ss e, W
I 5
Ph on e
(6
) 7
-2
(6
) 7
-2
F an ta R ee d
R oa d La
C ro ss e, W is co ns in
As indicated
A100
DEMOLITION PLAN
BID
DOCUMENTS
BG/SDM
02/03/2017
0319.14
U pp er M id w es t E nv iro nm en ta l S ci en ce s
C en te r
Fi sh
H ol di ng
R en ov at io n
1/8" = 1'-0"1 DEMOLITION PLAN
DEMOLITION KEY NOTES
MARK DESCRIPTION
D1 REMOVE EXISTING TRENCH DRAIN GRATING'S. REFER TO FLOOR
SLAB SAW CUTTING PLAN ON SHEET A102.
D2 REMOVE EXISTING HOLLOW METAL DOOR. EXISTING FRAME TO
REMAIN FOR RE-CONDITIONING AND PAINTING.
D3 REMOVE EXISTING H.M. DOOR PAIR INCLUDING H.M. FRAME.
D4 EXISTING EXPANSION JOINT SEALANT TO BE RAKED OUT AND
RE-SEALED
D5 EXISTING AHU TO REMAIN IN PLACE
D6 REMOVE EXISTING RESILIENT BASE
D7 REMOVE EXISTING OVERHEAD SECTIONAL DOOR
NORTH
(SEE SHEET A102 FOR SLAB CUTTING PLAN)
ELEV. EQUIP
ELEC.
C108
OFFICE
WET LAB
C104-b
WET LAB
C104-c
OFFICE
C104-d
LAB
C104-e
LAB
C104-f
C104-a
C104-b
C104-c
C104.1
C104-d
C104-e
ROW1 ROW2 ROW3 ROW4
FISH HOLDING
C104
C
.2
SEWAGE
EJECTOR PIT
FILTER PIT
SOLIDS
INTERCEPTOR
SOLIDS
INTERCEPTOR
22 1
3 4
3 4
3 4
3 4
3 4
3 4
LIMIT OF
WORK
A103
C104-f
ROW5
C104.3
R
ID
G E L
IN
E
T R
E N C H D
R A
IN
R
ID
G E L
IN
E
T R
E N C H D
R A
IN
R
ID
G E L
IN
E
T R
E N C H D
R A
IN
R
ID
G E L
IN
E
T R
E N C H D
R A
IN
T R
E N C H D
R A
IN
SLOPESLOPESLOPESLOPESLOPESLOPESLOPESLOPESLOPE
F1
HOLLOW METAL
F2
HOLLOW METAL
2"2"2"SEE SCHEDULE2"
SEE PLAN SEE PLAN
7'
7'
8" x 24"DOOR
GRILLE SEE DOOR
SCHED. FOR SIZE
6"6"
1'
9"8"
1'
9"
DOOR TYPE 'A' DOOR TYPE 'B' DOOR TYPE 'C'
1/4" FIRE RATED
SAFETY GLASS
GL-2. SEE SPEC
FOR INSULATED
(GL-1) EXTERIOR
GLASS.
S E E S
C H E D
UL
E
SEE SCHEDULE SEE SCHEDULE
1'
1'
1' - 9"
SEE SCHEDULE
6"6"
SEE SCHEDULE
DOOR TYPE 'D'
ALUMINUM SASH SECTION
W/ DSB GLAZING
3/4" RADIUS COVE
HPFC
CMU SUBSTRATE
EXISTING
MORTAR JOINT
N O
M
IN
A
CAULK BOTH
SIDES
HM FRAME
GROUT FILLED
SEE DOOR
SCHEDULE FOR
DOOR TYPE
8 3/4"
EXISTING CMU WALL
CAULK BOTH
SIDES
HM FRAME
GROUT FILLED
SEE DOOR
SCHEDULE FOR
DOOR TYPE
8 3/4"
TOP COAT
BASE COURSE SLURRY
FLOOR SLAB
TRENCH DRAIN
SPEC SECTION 09 96 00
N . T hi rd
S
C ro ss e, W I
(6
) 7
-2
Ph (6
) 7
-2
Fa x
AR
CH
IT
EC
TS
IN
C
Scale:
SHEET NO.
SHEET TITLE
NO.
REVISIONS
SET TYPE:
DRAWN BY:
DRAWING DATE:
PROJECT NO:
DATE
COPYRIGHT C 2012 VANTAGE ARCHITECTS, INC.
PR
O
JE
C
T
TI
TL
E:
PR
O
JE
C
T
LO
C
AT
IO
N
A
R C
H I T
E C
T S
I N C
N . T hi rd
S
C ro ss e, W
I 5
Ph on e
(6
) 7
-2
(6
) 7
-2
F an ta R ee d
R oa d La
C ro ss e, W is co ns in
As indicated
A101
INTERIOR
FINISHES PLAN &
SCHEDULES
BID
DOCUMENTS
BG/SDM
02/03/2017
0319.14
U pp er M id w es t E nv iro nm en ta l S ci en ce s
C en te r
Fi sh
H ol di ng
R en ov at io n
1/8" = 1'-0"1 INTERIOR FINISHES PLAN & SCHEDULES
NORTH
ROOM FINISH PLAN KEY NOTES
MARK DESCRIPTION
1 APPLY NEW HIGH PERFORMANCE FLOOR COATING PER SPEC SECTION
09 96 00.
2 APPLY EPOXY COATING TO COLUMNS, FULL HEIGHT.
3 RECONDITION EXISTING H.M. FRAME AND PAINT PER SPEC SECTION 09
90 00.
4 PAINT NEW H.M. DOOR
5 COVE HIGH PERFORMANCE FLOOR COATING UP WALL 8".
6 EXISTING QUARRY TILE FLOORING TO REMAIN.
3/8" = 1'-0"2 DOOR & FRAME ELEVATIONS
DOOR SCHEDULE
DOOR NO. DOOR SIZE
DOOR
TYPE
DOOR
ELEVATION
FRAME
TYPE
FRAME
ELEVATION
HEAD
DETAIL
JAMB
DETAIL LABEL HARDWARE NOTES
C104-a PR. 2'-10"/2'-10" x 7'-10" H.M. A EXISTING F2 5/A101 4/A101 GROUP 4 C104-b 3'-0" x 7'-10" H.M. B EXISTING F1 5/A101 4/A101 GROUP 1 C104-c 3'-0" x 7'-10" H.M. B EXISTING F1 5/A101 4/A101 GROUP 1 C104-d 3'-0" x 7'-10" H.M. B EXISTING F1 5/A101 4/A101 GROUP 2 C104-e 3'-0" x 7'-10" H.M. B EXISTING F1 5/A101 4/A101 GROUP 1 C104-f 3'-0" x 7'-10" H.M. B EXISTING F1 5/A101 4/A101 GROUP 1 C104.1 PR. 2'-10"/2'-10" x 7'-10" H.M. C H.M. F2 5/A101 4/A101 B GROUP 3
C104.2 EXISTING EXISTING EXISTING EXISTING F1 EXISTING
C104.3 12'-0" X 10'-0" O.H.S. D EXISTING N/A
3" = 1'-0"3 HIGH PERFORMANCE FLOOR COATING COVE
1 1/2" = 1'-0"4 H.M. JAMB DETAIL
1 1/2" = 1'-0"5 H.M. HEAD DETAIL
NOT TO SCALE6 TRENCH COATING
ELEV. EQUIP
WET LAB
C104-b
ELEC.
C108
WET LAB
C104-c
OFFICE
CORRIDOR
OFFICE
C104-d
JAN. 29
LAB
C104-e
OFFICE 22
LAB
C104-f
3' - 0"3' - 0"3' - 0"3' - 0"
INDOOR AHU
ABOVE
FISH HOLDING
C104
COL.
COL.
COL.
COL.
COL.
COL.
A102PIC.
A102
E .J
E .J
E .J
C104-e
C104-d
C104.1
ROW1 ROW2 ROW3 ROW4
6" SLAB W/
6 x 6 - 4/4 WWF
5" SLAB W/
6 x 6 - 4/4 WWF
T/ SLAB 651' - 0"
11111 1
11' - 7" 14' - 0" 7' - 0" 7' - 0" 7' - 0" 7' - 0"
4 4
EXISTING COL.
FOOTING
T/ FTG
648' - 4"
ROW5
EXISTING SLAB
1' - 6 1/2"
HAMMER OUT SLAB SECTIONS
BETWEEN SAW CUTS.
SLOPE
REMOVE CONTINUOUS
SUPPORT ANGLE AND STRAP
ANCHOR (BOTH SIDES)
3" 3" 3"3" 3" 3"
RIBBON CUTS @ 3" O.C. CUTS TO
EXTEND 1" BELOW BOTTOM OF SLAB.
EXISTING TRENCH
GRATING TO BE
REMOVED
S E E P
L A N
EXISTING SLAB
EXISTING 6x6 - 4/4 WWF
V A R
IE
S
1' - 4"
RIBBON CUTS
SLAB SAW CUTTING NOTES
THE INTENT IS TO REMOVE THE EXISTING CONCRETE ON BOTH SIDES
OF THE EXISTING GRATING. CUT OUT PERIMETER SUPPORT ANGLE
AND EMBEDDED ANCHORS.
THE SAW CUTTING OF THE SLAB BOTH SIDES OF THE TRENCH DRAIN
TO BE HELD STRAIGHT AND CONSISTANT. SAW CUT WILL BE SEALED
WITH TRAFFIC GRADE SEALANT AND BACKER ROD. REFER TO SPEC
SECTION 07 92 00 - JOINT SEALANTS.
ALL LOCATIONS OF SAW CUTTING TO BE FIELD VERIFIED. SLAB
REMOVAL CALLED OUT AS KEY NOTES 4 AND 5 TO BE ADJUSTED AS
NECESSARY TO PREVENT UNDERMINING OF SLAB AREAS TO REMAIN.
CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL
TEMPORARY SHORING OF EXCAVATIONS.
BASED ON ORIGINAL PLANS, THE FLOOR SLAB CHANGES TO 6"
THICK AT ROW 4. SLABS ARE REINFORCED WITH 6x6 - 4/4 WWF.
EXISTING ELEVATIONS OF TRENCH DRAINS TO BE MAINTAINED.
A.
B.
C.
D.
E.
F.
N . T hi rd
S
C ro ss e, W I
(6
) 7
-2
Ph (6
) 7
-2
Fa x
AR
CH
IT
EC
TS
IN
C
Scale:
SHEET NO.
SHEET TITLE
NO.
REVISIONS
SET TYPE:
DRAWN BY:
DRAWING DATE:
PROJECT NO:
DATE
COPYRIGHT C 2012 VANTAGE ARCHITECTS, INC.
PR
O
JE
C
T
TI
TL
E:
PR
O
JE
C
T
LO
C
AT
IO
N
A
R C
H I T
E C
T S
I N C
N . T hi rd
S
C ro ss e, W
I 5
Ph on e
(6
) 7
-2
(6
) 7
-2
F an ta R ee d
R oa d La
C ro ss e, W is co ns in
As indicated
A102
SLAB CUTTING
PLAN
BID
DOCUMENTS
BG/SDM
02/03/2017
0319.14
U pp er M id w es t E nv iro nm en ta l S ci en ce s
C en te r
Fi sh
H ol di ng
R en ov at io n
1/8" = 1'-0"1 FLOOR SLAB SAW CUTTING PLAN
1 1/2" = 1'-0"3 SECTION THRU EXISTING TRENCH DRAIN
NORTH
NOT TO SCALE2 EXISTING FLOOR TRENCH CONDITION
SAW CUTTING KEY NOTES
MARK DESCRIPTION
1 SAW CUT EXIST. CONCRETE SLAB PARALLEL TO FLOOR
TRENCH GRATING. NOTE SLAB THICKNESS CHANGE ALONG
TRENCH ROW 4.
2 SAW CUT AND REMOVE AREA OF EXISTING SLAB FOR NEW
FLOOR DRAIN AND DISINFECTANT WALK-OVER FLOOR PADS.
VERFIY EXACT SIZE WITH ARCHITECT.
3 SAW CUT AND REMOVE EXISTING SLAB FOR INSTALLATION OF
NEW UNDERSLAB DRAIN LINE. REFER TO SHEET P/102.
4 SAW CUT AND REMOVE EXISTING SLAB AS NECESSARY TO
INSTALL SOLIDS INTERCEPTOR TANK. REFER TO PLUMBING
PLANS.
5 SAW CUT AND REMOVE EXISTING SLAB AS NECESSARY TO
FORM AND CAST NEW FILTER PIT AND SEWAGE EJECTOR PIT.
6 THE SAW CUT FOR THE RECESSED PITS WILL REQUIRE
REPLACING FULL SECTIONS OF TRENCH DRAIN.
ELEV. EQUIP
WET LAB
C104-b
ELEC.
C108
WET LAB
C104-c
OFFICE
CORRIDOR
OFFICE
C104-d
JAN. 29
LAB
C104-e
OFFICE 22
LAB
C104-f
3' - 0"3' - 0"3' - 0"3' - 0"
INDOOR AHU
ABOVE
FISH HOLDING
C104
COL.
COL.
COL.
COL.
COL.
COL.
E .J
E .J
E .J
C104-e
C104-d
C104.1
EXISTING
EYEWASH
C104-a
ROW1 ROW2 ROW3 ROW4
C104-c
C104-b
SEWAGE
EJECTOR PIT
FILTER PITSOLIDS
INTERCEPTOR
SOLIDS
INTERCEPTOR
A103
9'
11' - 7" 14' - 0" 14' - 0" 14' - 0"
A103
A103
C
.2
ROW5
C104-f
TYP.
TYP.
BOT. / TRENCH
-20"
BOT. / TRENCH
-26" TRENCH DEPTH
(TYP. @ CENTER ROW)
C104.3
2" HIGH STAINLESS STEEL
BEARING BARS SPACED
1.1875" O.C.
TYPICAL GRATE SECTION
CROSS BARS SPACED
4" O.C.
LINE OF EMBEDED
ANGLE
OPENING LOCATIONS AND
SIZES TO BE FIELD VERIFIED.
INCLUDE WITH SHOP DRAWING
SUBMITALS.
20"
PROVIDE SHOP CUT
OPENINGS REQUIRED FOR
ROUTING PIPE RISERS
MODIFIED GRATE SECTION
4"4"4"4"4"
20"
(N
O M
IN
A L
SLOPE
V A R
IE
S
CONCRETE
BONDING
AGENT
CRACK BRIDGING
TRAFFIC SEALANT (TYP.)
EXISTING CONCRETE
SLAB AND FORMED
TRENCH DRAIN.
HIGH PERFORMANCE
FLOOR COATING PER
SPEC SECTION 09 96 00.
STAINLESS STEEL EMBED
ANGLE - SEE 5/A103
EXISTING 6X6 - 4/4 WWF
NEW STAINLESS STEEL
BAR GRATING
BOT. /TRENCH
VARIES
2" 16" 2"
FIELD VERIFY EXACT
TRENCH WIDTH
F.D.
4' - 6" 6"
9"
9"
APPLY SAME HIGH
PERFORMANCE FLOOR
COATING AS SURROUNDING
FLOOR SLAB.
EXISTING WALL RECESS TOP OF SLAB
SUMP 5/8" AND SLOPE
TO FLOOR DRAIN.
2.1 A103
SLOPE
1/4" PER FT
SLOPE
1/4" PER FT
CRACK BRIDGING
TRAFFIC GRADE
SEALANT
6"
16"
3/8" SLIDE IN STAINLESS STEEL
CUT-OFF PLATE
POLYPRENE BULB TYPE
WEATHER STRIP ATTACHED
TO BOTTOM EDGE OF CUT-
OFF PLATE - BOTH SIDES
CUT-OFF PLATE TO SLIDE
BETWEEN 1"x1" BACK TO
BACK STAINLESS STEEL
ANGLE GUIDE ATTACHED TO
1/4" THICK S.S. BACK PLATE
ANCHOR PLATE TO INSIDE
FACE OF CONCRETE TRENCH
WITH 1/4" DIA. x 3 1/2" LONG
CONCRETE SCREW ANCHORS.
ADHERE 3/8" THICK
COMPRESSIBLE FOAM TO
BACK SIDE OF PLATE.
HAND HOLD CUT-OUTS
GENERAL NOTES
A. ALL EXISTING DIMENSIONS SHALL BE FIELD VERIFIED BY THE
CONTRACTOR AND COMPARED AGAINST DRAWINGS. REPORT
CONFLICTS TO ARCHITECT.
B. IT IS INTENDED THAT EXISTING CONCRETE FLOOR TRENCHES
REMAIN IN PLACE. MODIFICATIONS REQUIRED TO EXISTING STEEL
BAR GRATINGS ARE SHOWN ON DETAIL 4/A105.
INTERIOR FINISHES PLAN &
SCHEDULES
651' - 0"
9" 2' - 3" 2' - 3" 9"
EXISTING SLAB NEW 5" SLAB W/
WWF 6 X 6 - 10/10
1/4" / 1'-0"
/8
#4 x 1' - 6" LONG DOWELS
DRILLED INTO EXISTING
SLAB. SPACE 24" O.C.
EXISTING AGGREGATE BASE.
REGRADE AND COMPACT.
NEW UNDER SLAB DRAIN PIPE
RECESS PERIMETER
FOR FLOOR PAD 5/8"
TRAFFIC GRADE CRACK
BRIDGING SEALANT
1/
/4
1/
1 3/4" 1/4"
SLOPE
RADIUS EDGE
APPLY HIGH PERF.
COATING TO BE FACE
OF CONCRETE PRIOR
TO INSTALLING EMBED
ANGLE
CONCRETE
STAINLESS
STEEL HWS
ANCHORS
FILLET PROFILE SEALANT
N . T hi rd
S
C ro ss e, W I
(6
) 7
-2
Ph (6
) 7
-2
Fa x
AR
CH
IT
EC
TS
IN
C
Scale:
SHEET NO.
SHEET TITLE
NO.
REVISIONS
SET TYPE:
DRAWN BY:
DRAWING DATE:
PROJECT NO:
DATE
COPYRIGHT C 2012 VANTAGE ARCHITECTS, INC.
PR
O
JE
C
T
TI
TL
E:
PR
O
JE
C
T
LO
C
AT
IO
N
A
R C
H I T
E C
T S
I N C
N . T hi rd
S
C ro ss e, W
I 5
Ph on e
(6
) 7
-2
(6
) 7
-2
F an ta R ee d
R oa d La
C ro ss e, W is co ns in
As indicated
A103
TRENCH LAYOUT
PLAN
BID
DOCUMENTS
BG/SDM
02/03/2017
0319.14
U pp er M id w es t E nv iro nm en ta l S ci en ce s
C en te r
Fi sh
H ol di ng
R en ov at io n
1/8" = 1'-0"1 FLOOR PLAN W/ TRENCH LAYOUT
NORTH
FLOOR PLAN KEY NOTES
MARK DESCRIPTION
1 NEW FLOOR TRENCH GRATING. REFER TO DETAILS ON THIS
SHEET.
2 CONCRETE FLOOR TRENCH WALL REPLACEMENT. SEE DETAIL
4/A103
3 REPLACE EXISTING H.M. DOOR WITH NEW H.M. DOOR INSTALLED
IN EXISTING FRAME. FRAME TO BE RECONDITIONED, PAINT PER
SPEC SECTION 09 90 00.
4 APPLY HIGH PERFORMANCE COATING PER SPEC SECTION 09 96
00.
5 EXISTING FLOOR EXPANSION JOINT. REPLACE SEALANT WITH NEW
TRAFFIC GRADE SEALANT.
6 NEW DISINFECTANT WALK-OVER FLOOR PAD SLAB RECESS. SEE
DETAILS ON THIS SHEET.
7 INSTALL NEW H.M. DOOR IN EXISTING H.M. FRAME. RECONDITION
AND PAINT PER SPEC SECTION 09 90 00.
8 RECONDITION EXISTING H.M. SIDELITE FRAMING AND PAINT.
9 PATCH IN CONCRETE SLAB OVER COMPACTED BASE
FOLLOWING CONNECTION AND TESTING OF RECESSED PIT.
10 TRENCH CUT-OFF PLATE ASSEMBLY PER DETAIL 6/A103
11 REPLACE EXISTING OVERHEAD SECTIONAL DOOR.
12 PATCH TRENCHED SLAB BETWEEN NEW FLOOR DRAIN AND
CONCRETE FLOOR TRENCH.
13 EXISTING SHELVING AND EQUIPMENT TO BE REMOVED AND
RE-INSTALLED BY OWNER.
14 EXISTING WORK STATION FURNISHINGS TO REMAIN IN PLACE.
15 PIT EXCAVATION WILL REQUIRE REPLACEMENT OF COMPLETE
EXISTING CONCRETE FLOOR TRENCH TO MATCH DETAIL 4/A103.
16 PATCH CONCRETE SLAB AND REPLACE SECTION OF CONCRETE
FLOOR TRENCH AS NECESSARY AT AREA OF UNDERGROUND
PIPING
17 PIT LADDER : SEE SPEC SECTION 05 50 00
1 1/2" = 1'-0"3 BAR GRATE DETAIL
1 1/2" = 1'-0"4 NEW TRENCH DRAIN DETAIL
1/2" = 1'-0"2 ENLARGED PLAN AT DISINFECTANT WALK-OVER FLOOR PAD
NOT TO SCALE6 TRENCH DAM ASSEMBLY
1" = 1'-0"2.1 SECTION THRU DISINFECTANT WALK-OVER FLOOR PAD
12" = 1'-0"5 FIBER GLASS EMBEDMENT ANGLE(SEE SPEC SECTION 05 53 00)
GENERAL NOTES
1. THE CONTRACTOR IS RESPONSIBLE FOR JOB SITE SAFETY REQUIREMENTS.
2. THE BUILDING STRUCTURE IS DESIGNED TO FUNCTION AS A COMPLETE SYSTEM, AND HAS NOT BEEN ANALYZED OR DESIGNED FOR STABILITY DURING ERECTION. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO DESIGN AND PROVIDE ADEQUATE TEMPORARY BRACING TO INSURE STABILITY DURING THE ERECTION PROCESS.
3. THE CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTION MEANS AND METHODS, AND IS RESPONSIBLE TO INSURE THAT CONSTRUCTION LOADS DO NOT EXCEED THE DESIGN CAPACITY OF THE FRAMING ELEMENTS WHEN THOSE LOADS
ARE APPLIED.
4. DO NOT SCALE THE DRAWINGS.
5. THE CONTRACTOR IS REQUIRED TO COORDINATE THE STRUCTURAL DRAWINGS WITH THE ARCHITECTURAL, CIVIL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS, AND TO BRING ANY DISCREPANCIES, INTERFERENCES, DIMENSIONAL INCONSISTENCIES, OR CONCERNS ASSOCIATED WITH THIS COORDINATION TO THE ARCHITECT AND ENGINEER IMMEDIATELY.
DESIGN LOADS
APPLICABLE DESIGN CODE AND REFERENCES
THE CODES AND STANDARDS LISTED HAVE BEEN USED FOR THE DESIGN OF THIS PROJECT. ALL CONSTRUCTION, FABRICATION, AND MATERIALS SHALL CONFORM TO THESE CODES AND STANDARDS.
2009 INTERNATIONAL BUILDING CODE W/ WISCONSIN AMMENDMENTS
ASCE 7-05 MINIMUM DESIGN LOADS FOR BUILDINGS
ACI 318-05 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE
BUILDING DESIGN CRITERIA
BUILDING OCCUPANCY CATEGORY: II (SEE ASCE 7-05 TABLE 1-1)
BUILDING DESIGN LOADS AND DATA
LIVE LOADS
SLAB ON GRADE 100 PSF
OR
2-TON FORKLIFT (6.5 KIP WHEEL LOAD)
SOIL DESIGN DATA
SOIL UNIT WEIGHT 110 PCF (ASSUMED)
LATERAL EARTH PRESSURE - ACTIVE 40 PSF/FT OF DEPTH (ASSUMED)
LATERAL EARTH PRESSURE - AT-REST 60 PSF/FT OF DEPTH (ASSUMED)
PASSIVE EARTH PRESSURE 300 PSF (ASSUMED)
SUBGRADE MODULUS 150 PCI (ASSUMED)
ALLOWABLE SOIL BEARING PRESSURE 2,000 PSF (ASSUMED)
1. SEE SPECIFICATION DIVISION 03 FOR REQUIREMENTS IN ADDITION TO THOSE LISTED BELOW.
2. MATERIAL SPECIFICATIONS
FOOTINGS F’c = 4000 PSI @ 28 DAYS FOUNDATION WALLS F’c = 4000 PSI @ 28 DAYS SLAB ON GRADE F’c = 3000 PSI @ 60 DAYS CONCRETE NOT OTHERWISE NOTED F’c = 4000 PSI @ 28 DAYS MILD REINFORCING STEEL BARS Fy = 60 KSI; ASTM A615
WELDED WIRE REINFORCEMENT ASTM A185
EPOXY COATED WELDED WIRE REINFORCEMENT ASTM A884
3. SUBMIT CONCRETE MIX DESIGNS, WITH REQUIRED BACKUP DATA, INCLUDING RECENT GRADATIONS FOR EACH AGGREGATE USED, FOR EACH TYPE OF CONCRETE PROPOSED FOR USE, TO THE ARCHITECT AND ENGINEER FOR REVIEW A MINIMUM OF TWO WEEKS PRIOR TO PLACEMENT. SEE SPECIFICATIONS FOR ADDITIONAL MIX DESIGN REQUIREMENTS. CONCRETE MIXES SUBMITTED SHALL BE DESIGNED TO BE PLACABLE FOR THE TEMPERATURE CONDITIONS AT THE JOBSITE, AND BE ABLE TO BE PLACED AND CONSOLIDATED AROUND THE REINFORCING
INDICATED ON THE PLANS. DO NOT USE CALCIUM CHLORIDE IN ANY CONCRETE.
4. PROVIDE AIR-ENTERTAINING IN CONCRETE AS INDICATED IN THE SPECIFICATIONS.
5. ALL CONCRETE SHALL BE NORMAL WEIGHT (APPROX. 145 PCF) UNO.
6. SUBMIT DETAILED SHOP DRAWINGS INDICATING REINFORCEMENT SIZE, SPACING, BENDING, AND PLACEMENT TO THE ARCHITECT AND ENGINEER FOR REVIEW PRIOR TO FABRICATION.
INCLUDE DETAILS AND LOCATIONS OF ALL CURBS, CONSTRUCTION JOINTS, SLAB DEPRESSIONS, SLEEVES, OPENING, ETC.
7. THE MAXIMUM TOTAL AMOUNT OF WATER THAT MAY BE ADDED TO THE MIX AFTER BATCHING IS THE AMOUNT INDICATED AS BEING WITHHELD ON THE BATCH TICKET FOR THE SPECIFIC BATCH.
8. SUBMIT ELECTRONIC COPIES OF ALL CONCRETE DELIVERY TICKETS WITHIN 5 DAYS OF PLACEMENT, INDICATING THE FOLLOWING INFORMATION:
TIME AND NUMBER OF CUBIC YARDS BATCHED
THEORETICAL TARGET AND ACTUAL BATCH WEIGHTS OF EACH INGREDIENT
AMOUNT OF WATER WITHHELD
AMOUNT OF WATER ADDED AT JOBSITE
MIX DESIGN NUMBER
STRUCTURE BEING PLACED
LOCATION OF PLACEMENT
NUMBER OF REVOLUTIONS AT MIXING SPEED
TOTAL REVOLUTIONS AT COMPLETION OF DISCHARGE
TIME AT COMPLETION OF DISCHARGE
SLUMP AND AIR CONTENT, IF TESTED
TEMPERATURE OF AIR AND CONCRETE
SAMPLE NUMBERS OF CYLINDERS MADE FROM LOAD
9. DETAIL, FABRICATE, SUPPORT, AND PLACE ALL CONCRETE REINFORCEMENT IN ACCORDANCE WITH ACI 315 “DETAILS AND DETAILING OF CONCRETE REINFORCEMENT” AND ACI 318 “BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE”. FIELD BENDING OF REINFORCING BARS IS NOT PERMITTED EXCEPT WHERE INDICATED ON THE STRUCTURAL DRAWINGS.
10. COVERAGE FOR REINFORCEMENT SHALL NOT BE NOT LESS THAN:
11. SEE DETAIL FOR CLASS B TENSION CONTACT LAP SPLICE LENGTHS. STAGGER ADJACENT LAPS 3’ – 0” UNO.
12. PROVIDE (2) # 5 BARS DIAGONAL AT CORNERS OF OPENINGS AND AT RE-ENTRANT CORNERS. PROVIDE (2) # 5 BARS AROUND THE PERIMETER OF OPENINGS WITH SIDES
EXCEEDING 18 INCHES IN LENGTH.
13. WELDING OF GRADE A615 REINFORCING BARS IS NOT PERMITTED.
14. CLEAN AND MOISTEN ALL CONSTRUCTION JOINTS IMMEDIATELY PRIOR TO PLACING FRESH CONCRETE.
15. REFER TO THE ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR CURBS, PADS, DEPRESSIONS, WALL/SLAB OPENINGS, REVEALS, REGLETS, DRIPS, SPECIAL FLOOR
FINISHES, AND OTHER REQUIREMENTS NOT SHOWN ON STRUCTURAL DRAWINGS.
16. ALUMINUM CONDUIT SHALL NOT BE EMBEDDED IN CONCRETE.
17. DO NOT CAST OPENINGS OTHER THAN INDICATED ON THE REVIEWED SHOP DRAWINGS WITHOUT WRITTEN CONSENT OF EOR. DO NOT CORE HOLES IN COLUMNS, BEAMS, JOISTS, WALLS, OR
STRUCTURAL CONCRETE SLABS WITHOUT WRITTEN CONSENT OF THE EOR.
18. REFER TO ACI 305 FOR REQUIREMENTS FOR PLACING CONCRETE IN HOT WEATHER AND TO ACI 306 FOR REQUIREMENTS FOR PLACING CONCRETE IN COLD WEATHER.
19. ALL CONCRETE REINFORCEMENT TO BE EPOXY COATED.
CAST IN PLACE CONCRETE NOTES
S001
1. THE FOUNDATIONS HAVE BEEN DESIGNED TO THE ASSUMED VALUES INDICATED. SUBSURFACE CONDITIONS DESCRIBED SHALL BE CONSIDERED
APPROXIMATE AND CONFIRMED IN THE FIELD.
2. SEE SITE PLAN FOR ELEVATION DATUM EQUAL TO FIRST FLOOR TOP OF CONCRETE (ELEVATION 100'-0).
3. DO NOT UNDERMINE EITHER NEW OR EXISTING CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL SHORING NECESSARY FOR EXCAVATION ASSOCIATED WITH NEW
RECESSED PITS.
4. BEAR ALL FOOTINGS ON UNDISTURBED SOIL OR COMPACTED FILLS HAVING A MINIMUM NET ALLOWABLE BEARING CAPACITY INDICATED IN SOIL DESIGN DATA.
5. REMOVE UNSUITABLE SOIL MATERIAL AND DISPOSE OF OFF-SITE. PLACE ENGINEERED FILL AS REQUIRED IN HORIZONTAL LIFTS WITHIN +/-2 PERCENT OF OPTIMUM MOISTURE
CONTENT. COMPACT TO THE SPECIFIED DENSITY REQUIREMENTS.
6. MINIMIZE CONSTRUCTION TRAFFIC OVER EXPOSED SUBGRADES IF WET. DO NOT ALLOW WATER TO POND ON THE SUBGRADES.
7. THE GENERAL CONTRACTORS GEOTECHNICAL CONSULTANT MUST REVIEW AND APPROVE ALL FINISHED EXCAVATIONS AND BEARING SUBGRADES BEFORE PLACING CONCRETE.
PROVIDE ADDITIONAL EXCAVATION AS NECESSARY TO ACHIEVE THE REQUIRED BEARING CAPACITY.
8. USE SIDE FORMS FOR ALL FOOTINGS AND GRADE BEAMS. CLEAN REINFORCEMENT IMMEDIATELY PRIOR TO PLACING CONCRETE.
9. DO NOT PLACE CONCRETE IN ANY EXCAVATION CONTAINING FREE WATER, FROST, ICE OR FROZEN MATERIALS. PREVENT FROST OR ICE FROM PENETRATING ANY FOOTING OR SLAB SUBGRADE, BOTH BEFORE AND AFTER CONCRETE PLACEMENT AND UNTIL FOOTINGS OR SUBGRADES ARE FULLY PROTECTED BY THE PERMANENT BUILDING
STRUCTURE.
10. PLACE THE CONCRETE FOR EACH FOOTING IN ONE CONTINUOUS POUR.
11. BRACE FOUNDATION WALLS DURING THE OPERATION OF BACKFILLING AND COMPACTION.
12. BACKFILL AGAINST FOUNDATION WALLS SHALL BE PLACED IN LIFTS SUCH THAT THE DIFFERENCE IN ELEVATION ON OPPOSITE SIDES OF THE WALL DOES
NOT EXCEED 1’-6”.
FOUNDATION NOTES
CONDITION COVER
CONCRETE CAST AGAINST AND
PERMANENTLY EXPOSED TO EARTH
3"
CONCRETE EXPOSED TO EARTH OR WEATHER
#6 THROUGH #18 BARS
#5 BARS AND SMALLER 1- 1/2"
2"
CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT
WITH GROUND
SLABS, WALLS, & JOISTS
#14 & #18 BARS 1-1/2"
#11 BARS AND SMALLER 3/4"
BEAMS & COLUMNS
PRIMARY REINFORCEMENT, TIES, & SPIRALS 1-1/2"
LE
N
G T
H
D E
V E
LO
P
M E
N T
EXTENSION
Ld h
NOTES:
1. TOP BARS ARE DEFINES AT HORIZONTAL BARS WITH MORE THAN 12" OF CONCRETE BELOW.
2. TABLE VALUES BASED ON 1 1/2" CLEAR COVER AND MINIMUM CENTER TO CENTER BAR SPACING OF 6".
3. SPLICE LENGTH SHALL BE BASED ON LARGER BAR BEING SPLICED.
4. HOOKED BAR EXTENSION = MIN. BEND DIAMETER + 12db.
5. MIN. BEND DIAMETER = 6db FOR #3 - #8
8db FOR #9 - #11
6. HOOKED BAR DEVELOPMENT LENGTHS, Ldh, ASSUME
a) SIDE COVER ≥ 2 1/2" AND
b) COVER AT END OF EXTENSION ≥ 2"
BAR SIZE STANDARD TOP BAR
12" 12"
16" 20"
19" 24"
23" 29"
37" 48"
4,000 PSI CONCRETE
61"
75"
91"
109"
6"
7"
9"
10"
12"
14"
15"
17"
19"
#3
#4
#5
#6
#7
#8
#9
#10
#11
STD HOOK
DEVELOPMENT
LENGTH, Ldh
DEVELOPMENT LENGTHS
16" 16"
STANDARD TOP BAR
CLASS "B" TENSION
LAP SPLICE LENGTHS
12"
15"
18"
29"
36"
44"
54"
65"
15"
19"
23"
37"
47"
57"
70"
84"
47"
57"
70"
84"
LE
N
G T
H
LA
P
1. PREPARE SUBGRADE AS REQUIRED BY GENERAL CONTRACTORS GEOTECHNICAL CONSULTANT, TO MEET ASSUMED SOIL VALUES. AT A MINIMUM, PROOF
ROLL AND REMOVE ALL SOFT AREAS AND REPLACE WITH COMPATIBLE FILL.
2. SLAB ON GRADE TO BE CONSTRUCTED ON MINIMUM 15 MILL VAPOR BARRIER OVER GRANULAR FILL.
3. SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS AND SIZES OF SLAB DEPRESSIONS.
4. SLAB ON GRADE THICKNESS, ELEVATION, FLATNESS, LEVELNESS TOLERANCES:
THICKNESS: PLUS ½ INCHES; MINUS 0 INCHES
5. CONCRETE SLAB SHALL BE FINISHED IN ACCORDANCE WITH THE HIGH PERFORMANCE FLOOR COATING MANUFACTURER'S REQUIREMENTS.
6. WET CURE SLAB UNLESS NOTED OTHERWISE ON DRAWINGS.
7. ALL SLAB ON GRADE TO BE REINFORCED WITH EPOXY COATED WWF 6x6-W2.1/W2.1 LOCATED 1 1/2" FROM THE TOP OF THE SLAB.
- PROVIDE SUPPORTS, CHAIRS AND ACCESSORIES NECESSARY TO HOLD REINFORCE IN PROPER POSITION
- DO NOT PULL FABRIC/MESH IN PLACE DURING CONCRETING
- ALL WWF TO BE PROVIDED IN FLAT SHEETS
- HOLD WWF 1" CLEAR OF ALL CONTROL JOINTS
SLAB ON GRADE NOTES
LAP LENGTH
LA
P
L E
N G
T H
LAP LENGTH LAP LENGTH
INTERSECTIONCORNER
CONER BARS
SAME SIZE AND SPACING
AS WALL BARS
LA
P
L E
N G
T H
CONER BARS
SAME SIZE AND SPACING
AS WALL BARS
STANDARD WALL
REINFORCING
STANDARD WALL
REINFORCING
SEE DETAIL FOR LAP LENGTHS
S001
N
T h ir d S tr e e t
C ro s s e W
I
(6
-2
P h
(6
-2
F a x
A R
C H
IT
E
C T
S
IN
C
Scale:
SHEET NO.
SHEET TITLE
REVISIONS
SET TYPE:
DRAWN BY:
DRAWING DATE:
PROJECT NO:
P R
O J E
C T
T
IT
L E
P R
O J E
C T
L O
C A
T
IO
N
A R
C H
I T
E C
T S
I N C
N
T h ir d S t r e
C ro s s e W
I
P h o n e
-2
F x
(6
-2
STRATEGIC STRUCTURAL DESIGN, LLC
725 HEARTLAND TRAIL, SUITE 203
MADISON, WI 53717
(608) 841-1850 www.strategicstructural.com
SSD Project No. 160165
S tr a te g ic
S tr u c tu ra l D e s ig n L L
C
A ll ri g h ts r e s e rv e d N o p a rt o f th is d o c u m e n t m a y b e re p ro d u c e d o r u ti liz e d i n a n y f o rm w it h o u t p ri o r w ri tt e n a u th o ri z a ti o n f ro m S tr a te g ic S tr u c tu ra l D e s ig n L
L C
EXISTING CONDITIONS:
ALL INFORMATION REGARDING EXISTING STRUCTURE IS
SOLELY BASED ON EXISTING DOCUMENTATION PROVIDED.
NO EXISTING STRUCTURAL ELEMENTS NOR THEIR
LOCATIONS HAVE BE VERIFIED BY THE STRUCTURAL
ENGINEER AND MUST BE DISCOVERED, FIELD MEASURED
AND LOCATED PRIOR TO CONSTRUCTION OR MATERIAL
FABRICATION. IF EXISTING CONDITIONS DIFFER FROM THIS
DOCUMENT, NOTIFY THE STRUCTURAL ENGINEER FOR
POSSIBLE REMEDIAL WORK.
As indicated
S001
STRUCTURAL
GENERAL NOTES
BID DOCUMENTS
JJF
02/03/2017
1081.55
U p p e r
M id w e s t E n v ir o n m e n t a l S c ie n c e s
F a n ta
R e e d R o a d
L a C ro s s e W
I
C e n te r F is h H o l d in g R e n o v a ti o n
STRUCTURAL SHEET INDEX
SHEET
NUMBER SHEET NAME CURRENT REVISION DATE CURRENT REVISION DESCRIPTION
S001 STRUCTURAL GENERAL NOTES
S101 FOUNDATION PLAN
1" = 1'-0"
REBAR LAP SPLICE LENGTHS
1/2" = 1'-0"
CORNER REINFORCEMENT
No. DESCRIPTION DATE
T/ FOOTING
SEE PLAN
T/ WALL
SEE PLAN
VARIES
B/ TRENCH
NORTH
F5
S F
P1
A
FOUNDATION LEGEND
COLUMN GRID MARK
COLUMN GRID LINE
STRIP FOOTING, SEE SCHEDULE
PIER, SEE SCHEDULE
SPREAD FOOTING, SEE SCHEDULE
FOUNDATION WALL, SEE PLAN
FOOTING STEP
96'-0"
SPREAD FOOTING MARK, SEE SCHEDULE
TOP OF SPREAD FOOTING ELEVATION
PIER MARK, SEE SCHEDULE
99'-4" TOP OF PIER ELEVATION
STRIP FOOTING MARK, SEE SCHEDULE
FOUNDATION PLAN GENERAL NOTES
1. SEE SHEET S001 FOR STRUCTURAL GENERAL NOTES.
2. VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS.
3. PROVIDE CORNER REINFORCEMENT AT ALL WALL INTERSECTIONS PER DETAIL
4. ALL REBAR TO BE EPOXY COATED.
5. TOP OF SLAB ELEVATION 100'-0" = EXISTING SLAB ELEVATION = 651'-0"
S001
S101
R
T
V.5
W
3635373332
S101
___________________________________________________________________________________________________________________4
S101
FD
1' - 4 1/2" 20' - 9" 30' - 0" 24' - 6"
A
A B
97'-4" ±
14'-0"x14'-0" B 14'-0"x14'-0"
B 14'-0"x14'-0"B 14'-0"x14'-0" B 16'-0"x16'-0"
B 16'-0"x16'-0"
TYPICAL
B 9'-0"x9'-0" B 9'-0"x9'-0" 94'-6" ±
94'-6" ±
C 4'-6"
94'-6"
C 1'-4"
C 4'-0"
D
E
E
E6" THICKNESS
EAST OF LINE
5" THICKNESS
WEST OF LINE
9' - 0" 5' - 0" 9' - 0" 4' - 0"
4"
16' - 0"
8" 9' - 6" 8" 4' - 6" 8"
5'
0" 1'
5'
8"
4" 8" 4'
8"
S101
95'-4"95'-4"
4'
7'
ALL SIDES
18" MIN CLEAR
S101
NOTE:
ALL REBAR TO BE
EPOXY COATED
F F
S101
94'-0"
93'-0"
D
S101
20" DEEP, SEE PLUMBING
26" DEEP, SEE PLUMBING
4'
4' - 6"
EXISTING COL
EXISTING COL
EXISTING COL
EXISTING COL
EXISTING COL
EXISTING COL
D D
F
LO
O R
R
ID
G E
L
IN
E E
LE
V
A T
IO
N
'-0
SEE DATA SHEETS
FOR PIT COVER
CONFIGURATIONS
97'-4" ±
F
LO
O R
R
ID
G E
L
IN
E E
LE
V
A T
IO
N
'-0
F
LO
O R
R
ID
G E
L
IN
E E
LE
V
A T
IO
N
'-0
F
LO
O R
R
ID
G E
L
IN
E E
LE
V
A T
IO
N
'-0
G G
G
G
FILTER PIT
SUMP PUMP
EXISTING SLAB
100' - 0"
T/ FILTER PIT
94' - 0"
REFER TO DETAIL FOR PIT
TYPICAL REINFORCEMENT
T H
IC
K
N E
S S
8" P
IT
S101
AND PLUMBING
SEE PLAN
REFER TO DETAIL FOR PIT
TYPICAL REINFORCEMENT
S101
PROPOSED SLABEXISTING SLAB
6" UNDERMINE
6"
#4 DOWEL x 1'-6" AT 24"
OC, CENTERED IN SLAB,
DRILL AND GROUT 6"
INTO EXISTING
LINE OF
EXCAVATION
S101
SPRAY APPLIED WATERPROOFING,
SEE SPECS
WATERSTOP, SEE
ARCH SPECS
WATERSTOP, SEE
ARCH SPECS
SPRAY APPLIED
WATERPROOFING,
SEE SPECS
PIT COVER PERIMETER
FRAME
SLOPE DOWN
S101
EXISTING SLAB
100' - 0"
FIBERGLASS LINER,
SEE PLUMBING
DOUBLE DOOR HATCH
LINE OF EXCAVATION
#4 AT 12" OC, EACH WAY, BOTTOM
#4 AT 8" OC, EACH
WAY, CENTERED
#4 DOWELS WITH
STD HOOK AT 16" OC
INTO PIT SLAB
(2) #4 x CONT, TOP
AND BOTTOM
#4 DOWEL x 1'-6" AT 24"
OC, CENTERED IN SLAB,
DRILL AND GROUT 6"
INTO EXISTING
6" UNDERMINE
6"
PROPOSED SLABEXISTING SLAB
WATERSTOP, SEE
ARCH SPECS T/ SEWAGE EJECTOR
93' - 0"
S101
HATCH AND PIT WIDTH
4' - 6"
3" C
LR
SPRAY APPLIED WATERPROOFING,
SEE SPECS
WET WELL - SEE PLUMBING
4' - 0" Ø
EXISTING SLAB
100' - 0"
T/ EXISTING FOOTING
94' - 6"
R
T/INTERCEPTOR PIT
95' - 4"
T H
IC
K
N E
S S
8" P
IT
SOLIDS
INTERCEPTOR
COMPACTED CRUSHED AGGREGATE
OR SAND FILL
CAST IRON GRATE
ADJUSTABLE RISER
EXISTING CONCRETE WALL
EXISTING CONCRETE STRIP
FOOTING
4' - 6" ±
WALL
10 1/2" ±
ALL SIDES
18" MIN CLEAR
#4 AT 12" OC, EACH WAY, BOTTOM
3"
VARIES
FOUNDATION PLAN KEY NOTES
A EXISTING THICKENED SLAB BELOW WALL ABOVE. ASSUME 1'-0" WIDTH AND 1'-0"
DEPTH, TAPERED AT 1:1 PITCH TO TYPICAL SLAB THICKNESS.
B EXISTING SPREAD FOOTING BELOW CONCRETE COLUMN. SEE PLAN FOR APPROXIMATE
SIZE.
C EXISTING STRIP FOOTING BELOW EXTERIOR 10 1/2" CONCRETE WALL. SEE PLAN FOR
APPROXIMATE SIZE.
D EXISTING CONCRETE FORMED TRENCH DRAIN. SAW CUT CONCRETE ON EACH SIDE AND
PATCH PER DETAIL TYPICAL ALL EXISTING TRENCH DRAINS.
E APPROXIMATE EXTENTS OF SLAB PATCH. MATCH EXISTING SLAB DEPTH. 5" THICKNESS
TYPICAL, 6" THICKNESS EAST OF CURB AS INDICATED ON PLAN. REINFORCED W/ EPOXY
WWF, SEE GENERAL NOTES. ADDITIONALLY, PROVIDE #4 EPOXY COATED DOWELS x 1'-6" LONG @ 24" OC, CENTERED IN SLAB, DRILL AND GROUT 6" INTO EXISTING AROUND PERIMETER
AT CONSTRUCTION JOINT.
F ACCESS HATCH APPROXIMATE LOCATION. SEE ARCH FOR SPEC, SIZE AND LOCATION.
G REBUILD CONCRETE FORMED TRENCH DRAIN. SEE DETAIL FOR REINFORCEMENT.
S101
S101
PROPOSED SLABEXISTING SLAB
#4 EPOXY COATED DOWEL x 1'-6"
@ 24" OC, CENTERED IN SLAB,
DRILL AND GROUT 6" INTO EXISTING
9"±9"±
S
LA
B 5"
M
IN
SLOPE DOWN
TO DRAIN
P A
D S
E E
A R
C H
R E
C E
S S
F
LO
O R
15 MIL UNDERSLAB VAPOR
RETARDER MEMBRANE
COMPACTED GRANULAR
SUBGRADE
SEAL JOINTS W/ EPOXY CRACK
& JOINT BRIDGING FILLER
EPOXY COATED WWF,
SEE GENERAL NOTES
EXISTING SLAB
100' - 0"
S101
S101
T/ FILTER PIT
94' - 0"
T/ SEWAGE EJECTOR
93' - 0"
REFER TO DETAIL
FOR PIT TYPICAL
REINFORCEMENT
S101
REFER TO DETAIL
FOR PIT TYPICAL
REINFORCEMENT
S101
DOUBLE DOOR
HATCH 48"x54", SEE ARCH
BENT DOWEL, MATCH PIT
REINF SIZE AND SPACING
TH
IC
KN
E
SS
M A
TC
H
P
IT
SEE DETAIL FOR
GRATING AND ANGLE
SPECS
S101
#4 EPOXY COATED BENT BAR @ 12" OC
(6) #4 EPOXY COATED x CONT
ALONG LENGTH
S101
WATERSTOP, SEE SPECSWATERSTOP, SEE SPECS
SPRAY APPLIED WATERPROOFING,
SEE SPECSSPRAY APPLIED WATERPROOFING,
SEE SPECS
9' - 6"
VARIES
PIT COVER
CRACK BRIDGING
SEALANT
5" M
IN
2'
P
IT
6" S
LA
B 3"
#4 EPOXY COATED
DOWELS @ 12" OC
EXISTING SLAB
100' - 0"
PULTRUDED FIBERGLASS
EMBED ANGLE
#4 BENT DOWEL (12"x12") EPOXY
COATED AT 32" OC, DRILL AND
EPOXY INTO EXISTING SLAB EDGE,
6" MIN
SAW CUT
#4 x CONT
EPOXY COATED
9"
HEAVY-DUTY PULTRUDED
FIBERGLASS TRENCH
GRATING, SEE ARCH
BONDING AGENT ON ALL SAW
CUT CONCRETE SURFACES
SIKA ARMATEC 110 EPOCEM
OR EQUAL
TRENCH DRAIN
1' - 4" ±
W
A
LL
S
V A
R
IE
S
C E
N T
E R
EXISTING SLAB
100' - 0"
S101
______________________________________________________________________________________________________ _____________DOOR HATCH, SEE ARCH
5' - 6"
PIT COVER
PIT COVER
PERIMETER
FRAME
S101
S101
6" WALL
2' - 0"
6" WALL
6" W
A
LL
2'
6" W
A
LL
94'-0"
92'-0"
SUMP PIT
N
T h ir d S tr e
C ro s s e W
I
(6
-2
P h
(6
-2
F a x
A R
C H
IT
E
C T
S
IN
C
Scale:
SHEET NO.
SHEET TITLE
REVISIONS
SET TYPE:
DRAWN BY:
DRAWING DATE:
PROJECT NO:
P R
O J E
C T
T
IT
L E
P R
O J E
C T
L O
C A
T
IO
N
A R
C H
I T
E C
T S
I N C
N
T h ir d S t r e
C ro s s e W
I
P h o n e
-2 x
(6
-2
STRATEGIC STRUCTURAL DESIGN, LLC
725 HEARTLAND TRAIL, SUITE 203
MADISON, WI 53717
(608) 841-1850 www.strategicstructural.com
SSD Project No. 160165
S tr a te g ic
S tr u c tu ra l D e s ig n L L
C
A ll ri g h ts r e s e rv e d N o p a rt o f th is d o c u m e n t m a y b e re p ro d u c e d o r u ti liz e d i n a n y f o rm w it h o u t p ri o r w ri tt e n a u th o ri z a ti o n f ro m S tr a te g ic S tr u c tu ra l D e s ig n L
L C
EXISTING CONDITIONS:
ALL INFORMATION REGARDING EXISTING STRUCTURE IS
SOLELY BASED ON EXISTING DOCUMENTATION PROVIDED.
NO EXISTING STRUCTURAL ELEMENTS NOR THEIR
LOCATIONS HAVE BE VERIFIED BY THE STRUCTURAL
ENGINEER AND MUST BE DISCOVERED, FIELD MEASURED
AND LOCATED PRIOR TO CONSTRUCTION OR MATERIAL
FABRICATION. IF EXISTING CONDITIONS DIFFER FROM THIS
DOCUMENT, NOTIFY THE STRUCTURAL ENGINEER FOR
POSSIBLE REMEDIAL WORK.
As indicated
S101
FOUNDATION
PLAN
BID DOCUMENTS
JJF
02/03/2017
1081.55
U p p e r
M id w e s t E n v ir o n m e n t a l S c ie n c e s
F a n ta
R e e d R o a d
L a C ro s s e W
I
C e n te r F is h H o l d in g R e n o v a ti o n
1/8" = 1'-0"
FOUNDATION PLAN
1/2" = 1'-0"
FILTER PIT FOUNDATION
1/2" = 1'-0"
SEWAGE EJECTOR PIT FOUNDATION
1/2" = 1'-0"
SOLIDS INTERCEPTOR PIT FOUNDATION
3/4" = 1'-0"
SECTION THRU FLOOR DRAIN
1/2" = 1'-0"
FILTER AND EJECTOR PIT DETAIL
3/4" = 1'-0"
TRENCH DRAIN
3/4" = 1'-0"
FILTER ACCESS HATCH
100'-0" = EXISTING SLAB 651'-0"
100'-0" = EXISTING SLAB 651'-0" 100'-0" = EXISTING SLAB 651'-0"
100'-0" = EXISTING SLAB 651'-0"
100'-0" = EXISTING SLAB 651'-0"
100'-0" = EXISTING SLAB 651'-0"
No. DESCRIPTION DATE
100'-0" = EXISTING SLAB 651'-0"
(REFER ALSO TO DETAIL 4/A103)
1/4" = 1'-0"
FILTER PIT - ENLARGED PLAN
100'-0" = EXISTING SLAB 651'-0"
100'-0" = EXISTING SLAB 651'-0"
FD-1 ZURN CAST IRON BODY, ADJUSTABLE STRAINER HEAD, COMBINATION INVERTIBLE
MEMBRANE CLAMP AND ADJUSTABLE COLLAR WITH NICKEL BRONZE TOP.
Z415-B
MANUFACTURER MODEL NO.TAG REMARKS
PLUMBING DRAIN SCHEDULE
FCO ZURN CAST IRON BODY, ADJUSTABLE FLOOR CLEANOUT WITH NICKEL BRONZE TOP AND
GAS AND WATERTIGHT ABS TAPERED BRONZE PLUG (USE IN FINISHED AREAS).
CAST IRON BODY, HEAVY DUTY CLEANOUT HOUSING, WITH NICKEL BROZE TOP
AND INTERNAL CLEANOUT (USE IN UNFINISHED AREAS, MECHANICAL ROOMS,
JANITOR CLOSETS, ETC.).
Z1400-BP
Z1474
CAST IRON BODY FERRULE WITH BRONZE PLUG.ZURN Z1440-BPYCO
DESCRIPTION
FLOOR DRAIN
FLOOR CLEAN OUT
YARD CLEAN OUT
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
ACCESS PANEL
APPROXIMATELY
ARCHITECTURAL
AVERAGE
BUILDING
BOTTOM
BOTTOM OF PIPE
BATHTUB
BRITISH THERMAL UNITS
BRITISH THERMAL UNITS PER HOUR
BALANCING VALVE
CEILING ACCESS PANEL
CUBIC FEET PER MINUTE
CUBIC FEET PER HOUR
CEILING
CLEANOUT
CONDUCTOR
CONTRACTOR
CENTER
COPPER
CHECK VALVE
COLD WATER
WATER FIXTURE UNITS
DETAIL
DRAINAGE FIXTURE UNITS
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
ELEVATION
EMERGENCY
EQUIPMENT
EXPANSION TANK
EXISTING TO REMAIN
ELECTRIC WATER HEATER
EXISTING
FUTURE
FLOOR CLEANOUT
FLOOR DRAIN
FINISHED FLOOR ELEVATION
FLOOR
FIREPROOF
FEET PER MINUTE
FEET PER SECOND
FLOOR SINK
FEET
FOOTING
FIXTURE UNITS
GAS
GALLON
GENERAL CONTRACTOR
GALLONS PER MINUTE
GALLONS PER HOUR
HOSE BIBB
HUB DRAIN
HEATING, VENTILATING & AIR CONDITIONING
HOT WATER
HOT WATER FIXTURE UNITS
HOT WATER RETURN
INSIDE DIAMETER
INVERT ELEVATION
INCHES
KNOCK-OUT
LAVATORY
POUNDS
POUNDS PER HOUR
MAXIMUM
MOP BASIN
MBH
MC
MEP
MFR
MIN.
MISC
MTD
MTG
NA
NIC
NO
NPS
NTS
OC
OD
OFCI
OFOI
PC
PCF
PD
PH
PLBG
POC
PP
PPH
PRV
PSF
PSI
PSIA
PSIG
PVC
RD
REC
RF
RI
RPZ
RV
S
SCH
SH
SHT
SOG
SPEC
SQ
SS
S/S
STD
T&P
TBR
TD
TDFU
TEMP
TOP
TOS
T STAT
TWFU
TYP
UNO
V
VB
VTR
W
W/
W/O
WHA
WCO
WC
WF
WH
WM
WSFU
WG
YCO
FD
FFE
FLR
FP
FPM
FPS
FS
FT
FTG
FU
G
GAL
GC
GPM
GPH
HB
HD
HVAC
HW
HWFU
HWR
ID
IE
IN
KO
L
LBS.
LB/HR
MAX
MB
AFF
AFG
AP
APPROX
ARCH
AVG
BLDG
BOT
BOP
BT
BTU
BTUH
BV
CAP
CFH
CFM
CLG
CO
COND
CONT
CTR
CU
CV
CW
CWFU
DET
DFU
DIA
DIM
DN
DWG
E
ELEV
EM
EQUIP
ET
ETR
EWH
EXST
F
FCO
THOUSANDS OF BTU PER HOUR
MECHANICAL CONTRACTOR
MECHANICAL, ELECTRICAL AND PIPING
MANUFACTURER
MINIMUM
MISCELLANEOUS
MOUNTED
MOUNTING
NOT APPLICABLE
NOT IN CONTRACT
NUMBER
NOMINAL PIPE SIZE
NOT TO SCALE
ON CENTER
OUTSIDE DIAMETER
OWNER FURNISHED, CONTRACTOR INSTALLED
OWNER FURNISHED, OWNER INSTALLED
PLUMBING CONTRACTOR
POUNDS PER CUBIC FOOT
PRESSURE DROP
PHASE
PLUMBING
POINT OF CONNECTION
POLYPROPYLENE
POUNDS PER HOUR
PRESSURE RELIEF VALVE
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
POUNDS PER SQUARE INCH ABSOLUTE
POUNDS PER SQUARE INCH GAUGE
POLYVINYL CHLORIDE
ROOF DRAIN
RECESSED
ROOF
ROUGH-IN
REDUCED PRESSURE ZONE VALVE
RELIEF VALVE
SLOPE
SCHEDULE
SHOWER
SHEET
SLAB ON GRADE
SPECIFICATION
SQUARE
SERVICE SINK
STAINLESS STEEL
STANDARD
TEMPERATURE AND PRESSURE
TO BE REMOVED
TRENCH DRAIN
TOTAL DRAIN FIXTURE UNITS
TEMPERATURE
TOP OF PIPE
TOP OF SLAB
THERMOSTAT
TOTAL WATER FIXTURE UNITS
TYPICAL
UNLESS OTHERWISE NOTED
VENT
VACCUM BREAKER
VENT THRU ROOF
WASTE
WITH
WITHOUT
WATER HAMMER ARRESTOR
WALL CLEANOUT
WATER CLOSET
WASH FOUNTAIN
WATER HEATER
WASHING MACHINE
WATER SUPPLY FIXTURE UNITS
WATER GAUGE
YARD CLEAN OUT
FIRE DEPARTMENT CONNECTIONFDC -
PLUMBING ABBREVIATIONS
FACTORY WIRED WALL MOUNTED DUPLEX CONTROL PANEL, 120 VOLT, SINGLE
PHASE, NEMA I ENCLOSURE, ELECTRIC ALTERNATOR, CIRCUIT BREAKER/MOTOR
PROTECTORS, MAGNETIC CONDUCTORS, CONTROLS AND LIGHT MOUNTED ON
THE INNER PANEL, TWO SPRING RETURN 3 POSITION TEST-OFF-AUTOMATIC
SELECTOR SWITCHES, TWO RUNNING PILOT LIGHTS (GREEN), HIGH WATER
ALARM (WITH RED LIGHT, BUZZER AND SILENCING SWITCH), TEST-AUTO-SILENCE
CIRCUIT TRANSFORMER, TWO COMBINATION MANUAL DISCONNECTS, AND
MOTOR CIRCUIT PROTECTIONS, ADJUSTABLE AMBIENT COMPENSATED
BI-METALLIC THERMAL OVERLOAD, INSTANTANEOUS MAGNETIC TRIP FOR SHORT
CIRCUIT PROTECTION AND THROUGH THE DOOR RESET.
PRESSURE SWITCHES OF NON-CORROSIVE MATERIAL WITH SWITCHES
SUPPORTED FROM A VERTICAL POLE: SWITCH INSTALLATION SHALL BE DUPLEX
AND HAVE FOUR FLOAT SWITCHES, ONE TO CLOSE PUMP CIRCUITS, ONE TO
START LEAD PUMP, ONE TO START LAG PUMP, AND ONE TO INTIATE HIGH WATER
ALARM.
TOPPS INDUSTRIES ALUMINUM ROUND 48" DIAMETER, 72" DEEP, 564 GALLON, WET WELL W/
ANTI-FLOATATION RING, 52" LOCKING COVER WITH 2 ACCESS PORTS AND ONE
INSPECTION PORT, 1/2" DUPLEX FIBERGLASS COVER W/ ACCESS. PROVIDE
BALLAST ANTI-FLOATATION PAD FOR SUMP.
SP-1
FB48X84
C48DFA COVER
WEIL
WEIL 3" SUBMERSIBLE WASTE WATER PUMP, 160 GPM @ 100 FT.HD (43 PSI), CAST
IRON CASE, CAST IRON IMPELLER, STAINLESS STEEL HARDWARE, STAINLESS
STEEL LIFTING CABLE, DOUBLE SEAL, 15 HP MOTOR @ 460 VOLT, 3 PHASE.
PUMP SYSTEM TO INCLUDE 2613 REMOVAL SYSTEM.
1633-N
SP-2 STANCOR ELEVATOR PIT SUMP PUMP. PUMP & OIL-MINDER CONTROL. 1/2 HP, 115 VOLT, 1
PHASE, WITH 2" DISCHARGE. PROVIDE CHECK VALVE ON DISCHARGE PIPING. 18"
DIAMETERx24" DEEP STEEL OR CONCRETE BASIN WITH SEALED, VENTED COVER.
OIL MINDER SYSTEM, OR SIMILAR, IS REQUIRED TO PREVENT OILS FROM BEING
DELIVERED TO THE EXTERIOR HOLDING PONDS
OIL-MINDER SE50
CB-275-GSI-1 SCHIER 275 GALLON LIQUID CAPACITY, 200 GALLON SOLIDS CAPACITY SOLIDS
INTERCEPTOR. FOR GRAVITY DRAINAGE APPLICATIONS ONLY. 3/8" SEAMLESS HIGH
DENSITY POLYETHYLENE WALLS.
MEDIUM DUTY BOLTED AND GASKETED FOLID COVERS (TYPICAL OF 2)
B3-90FI-1 FORSTA FILTERS VERTICAL FILTER. MAX FLOW RATE OF 400 GPM. AUTOMATIC BACKWASH SYSTEM.
SUMP PUMP
SOLIDS INTERCEPTOR
FILTER
FILTER PIT SUMP
PUMP
SEWAGE
EJECTOR
C24-M
DOUBLE WYE
WYE
WYE WITH VENT UP
TEE BRANCH
PLUMBING SYMBOLS, ABBREVIATIONS, SCHEDULES & SHEET INDEX
PIPE FITTINGS
FLANGE
UNION
ANCHOR
PIPE GUIDE
VALVE IN VERTICAL
POINT OF CONNECTION
PIPE CAP
TEE UP
TEE DOWN
ELBOW UP
ELBOW DOWN
REFERENCE SYMBOLS
EQUIPMENT NAME AND NUMBER
PLAN NOTE NUMBER
REVISION NUMBER
ELEVATION SYMBOL
DISTRIBUTION PIPING SYSTEMS:
COLD WATER
HOT WATER
HOT WATER RETURN
WASTE AND VENT SYSTEMS:
CLEARWATER WASTE
STORM
SUBSOIL DRAIN LINE
SANITARY VENT
SSD
ST
CWW
CWV CLEARWATER VENT
OD OVERFLOW DRAIN LINE
SITE PIPING SYSTEMS:
ST
SAN
W WATER LINE
SANITARY SEWER
STORM SEWER
PIPING SYSTEM LABELS
NOTE: NOT ALL SYMBOLS AND ABBREVIATIONS INDICATED HERE ARE USED IN THE DRAWINGS AND MAY NOT
APPLY TO THIS PROJECT. ADDITIONAL SYMBOLS MAY BE INDICATED IN THE DRAWINGS.
WASTE OR SOIL LINESAN
DRAIN VALVE
GATE VALVE
ANGLE VALVE
BALL VALVE
BUTTERFLY VALVE
HOSE BIBB AND WALL HYDRANT
THERMOMETER
PRESSURE GAUGE
CHECK VALVE
BALANCING VALVE
PRESSURE RELIEF VALVE
PIPE VALVES AND SPECIALTIES
LINE CONTINUATION BREAK
DETAIL REFERENCE
TOP DESIGNATES DETAIL NUMBER BOTTOM
DESIGNATES SHEET NUMBER
SECTION REFERENCE
TOP DESIGNATES SECTION NUMBER BOTTOM
DESIGNATES SHEET NUMBER
FCO
DRAINS AND CLEANOUTS
FLOOR DRAIN
ROOF DRAIN
HUB DRAIN
CLEANOUT
FIXTURE WASTE TRAP
FLOOR CLEANOUT
CO
UNDERFLOOR FOR WASTE OR SOIL,
SUBSOIL, STORM & FORCE MAIN
PIPELINE STRAINER
BACKFLOW PREVENTER
PLUMBING FIXTURE STOPS
WATER HAMMER ARRESTOR
GAS SHUTOFF VALVE
P1.10
VP
P1.10
HB
PIPING TO BE DEMOLISHED
FLOOR SINK
NOTE:
(X) PRIOR TO SYSTEM TYPE DENOTES EXISTING PIPING
(F) PRIOR TO SYSTEM TYPE DENOTES FUTURE PIPING
SOLENOID VALVE
MANUFACTURER MODEL NO.TAG REMARKS
PLUMBING EQUIPMENT SCHEDULE
DESCRIPTION
POINT OF DISCONNECTION
KEYPLAN
N
T h ir d S tr e
C ro s s e W
I
(6
-2
P h
(6
-2
F a x
A R
C H
IT
E
C T
S
IN
C
Scale:
SHEET NO.
SHEET TITLE
NO.
REVISIONS
SET TYPE:
DRAWN BY:
DRAWING DATE:
PROJECT NO:
DATE
COPYRIGHT C 2012 VANTAGE ARCHITECTS, INC.
P R
O J E
C T
T
IT
L E
P R
O J E
C T
L O
C A
T
IO
N
A R
C H
I T
E C
T S
I N C
N
T h ir d S t r e
C ro s s e W
I
P h o n e
-2 x
(6
-2
One Honey Creek Corporate Center 125 South 84th Street, Suite 401 Milwaukee, WI 53214-1470 414 / 259 1500 414 / 259 0037 fax
12" = 1'-0"
P001
PLUMBING
SYMBOLS,
SCHEDULES, AND
ABBREVIATIONS
BID
DOCUMENTS
MRK
02/03/2017
0319.14
U M
E S
C
F is h H o ld in g L a b R e m o d e l
L a C ro s s e W
I
PLUMBING SHEET INDEX
P001 PLUMBING SYMBOLS, SCHEDULES, AND ABBREVIATIONS
P101 PLUMBING DEMOLITION PLANS
P102 PLUMBING PLANS
P501 PLUMBING DETAILS
P502 PLUMBING DETAILS
(X)3/4" CW
FISH HOLDING
C-104
PREP/STORAGE
C-104F
DIAGNOSTIC LAB
C-104E
OFFICE
C-104D
INVERT LAB
C-104C
INVERT LAB
C-104B
ELECTRICAL
C-104A
R1
R2
R3
R4
R5
R6
R7
R8
R9
R10
R11
R12
R13
R14
R15
R16
R17
R18
R19
R20
R21
R22
R23
R24
R25
R26
R39
R38
R37
R36
R35
R34
R33
R32
R31
R30
R29
R28
R27
(X) PANELS S6 & V
1/2" XCA 1/2" XCA 1/2" XCA
1/2" XCA
1" XCA
1" XCA
1/2" XCA
1/2" XCA
1/2" XCA1/2" XCA
1/2" XCA
1/2" XCA
12"x12" SA
12"x12" XSA
(X)2" CW
(X)2" CW
(X)4" CW
EXISTING 4" STEEL PIPE FROM
UNDERGROUND TRANSITIONS
TO PVC AT ELBOW
(X)4" CW(X)4" CW(X)4" CW
(X)4" CW
(X)2" CW
(X)2" CW
(X)6" CW
(X)2" CW(X)2" CW (X)2" CW
(X)2" CW
EXISTING 3/4" PIPE
UP TO TANKS
(X)3/4" HW
(X)3/4" HW(X)3/4" HW
(X)3/4" HW (X)3/4" HW
(X)3/4" HW
(X)6" HW
ELECTRICAL
C-104A
INVERT LAB
C-104B
INVERT LAB
C-104C
OFFICE
C-104D
DIAGNOSTIC LAB
C-104E
FISH HOLDING
C-104
PREP/STORAGE
C-104F
R1
R2
R3
R4
R5
R6
R7
R8
R9
R10
R11
R12
R13
R14
R15
R16
R17
R18
R19
R20
R21
R22
R23
R24
R25
R26
R39
R38
R37
R36
R35
R34
R33
R32
R31
R30
R29
R28
R27
(X) 4" AUXILIARY
WATER SUPPLY
(X)3/4" HW
(X)3/4" HW
INFORMATION PERTAINING TO EXISTING PROJECT CONDITIONS, SUCH AS
LOCATIONS OF ARCHITECTURAL AND STRUCTURAL BUILDING COMPONENTS,
MECHANICAL AND ELECTRICAL EQUIPMENT, PIPING, DUCTWORK, ROUGH-INS AND
OTHER MISCELLANEOUS CONSTRUCTION, APPEARS ON PROJECT DRAWINGS.
THIS INFORMATION IS BASED ON AVAILABLE RECORDS AS WELL AS INFORMATION
COLLECTED WITH REASONABLE CARE AT THE PROJECT SITE. CONTRACTORS
SHALL BE SOLELY RESPONSIBLE FOR VERIFYING DIMENSIONS AND RELATED
INFORMATION AT THE PROJECT SITE PRIOR TO PROCURING ANY MATERIALS,
PRODUCTS OR EQUIPMENT TO PERFORM THEIR WORK.
EXISTING PROJECT CONDITIONS
N
T h ir d S tr e
C ro s s e W
I
(6
-2
P h
(6
-2
F a x
A R
C H
IT
E
C T
S
IN
C
Scale:
SHEET NO.
SHEET TITLE
NO.
REVISIONS
SET TYPE:
DRAWN BY:
DRAWING DATE:
PROJECT NO:
DATE
COPYRIGHT C 2012 VANTAGE ARCHITECTS, INC.
P R
O J E
C T
T
IT
L E
P R
O J E
C T
L O
C A
T
IO
N
A R
C H
I T
E C
T S
I N C
N
T h ir d S t r e
C ro s s e W
I
P h o n e
-2 x
(6
-2
One Honey Creek Corporate Center 125 South 84th Street, Suite 401 Milwaukee, WI 53214-1470 414 / 259 1500 414 / 259 0037 fax
As indicated
P101
PLUMBING
DEMOLITION
PLANS
BID
DOCUMENTS
BSP
02/03/2017
0319.14
U M
E S
C
F is h H o ld in g L a b R e m o d e l
L a C ro s s e W
I
1/8" = 1'-0"1
PLUMBING DEMOLITION PLAN - ABOVE SLAB
1/8" = 1'-0"2
PLUMBING DEMOLITION PLAN - BELOW GRADE
N
N
KEYED NOTES THIS SHEET:
1. REMOVE EXISTING HVAC SUPPLY GRILLE AND ASSOCIATED DUCTWORK BACK TO MAIN
DUCT. PATCH EXISTING OPENING TO MATCH EXISTING. CAP EXISTING DUCTWORK AT
DISCONNECTION POINTS.
DEMOLITON GENERAL NOTES:
1. ALL PIPING IN DRAINAGE TRENCHES TO BE REMOVED AFTER
NEW HOT AND COLD WATER SUPPLY PIPING HAS BEEN INSTALLED
2. ALL COMPRESSED AIR PIPING AND HANGARS TO BE REMOVED
AFTER NEW PIPING HAS BEEN INSTALLED
1 1/2" CA
6" CW
(240 GPM)
6" CW
(65 GPM)6" CW
(140 GPM)
6" CW
(190 GPM)
6" CW
(240 GPM)
YCO
1" HW & CW DROP TO
AERATOR TUBE.
1/2" AIR DROP TO AIR
STONE AERATOR.
SEE DETAIL 3/P502
(TYPICAL)
3/4" CW DROP TO HB-1
3/4" DROP TO HOSE
BIB ON WALL
HB-1
HB-1
CAP AND VALVE FOR
FUTURE CONNECTION
BACKWASH CONTROL PANEL
(SEE ELECTRICAL DRAWINGS)
2" CW
(5 GPM)
2" HW
(5 GPM)
2" CW
(5 GPM)
2" CW
(5 GPM)
2" CW
(10 GPM)
2" CW
(15 GPM)
2" CW
(20 GPM)
2" CW
(25 GPM)
2" CW
(5 GPM)
2" CW
(5 GPM)
2" CW
(10 GPM)
2" CW
(15 GPM)
2" CW
(20 GPM)
2" CW
(10 GPM)
2" CW
(10 GPM)
2" CW
(10 GPM)
2" CW
(25 GPM)
2" CW
(30 GPM)
2" CW
(5 GPM)
2" CW
(10 GPM)
2" CW
(25 GPM)
2" CW
(20 GPM)
2" CW
(15 GPM)
2" CW
(10 GPM)
2" CW
(20 GPM)
2" CW
(15 GPM)
2" CW
(10 GPM)
2" CW
(25 GPM)
2" CW
(20 GPM)
2" CW
(15 GPM) 2" CW
(15 GPM)
2" CW
(20 GPM)
2" CW
(25 GPM)
2" CW
(25 GPM)
2" CW
(30 GPM)
2" CW
(45 GPM)
2" CW
(35 GPM)
2" CW
(15 GPM)
2" CW
(20 GPM)
2" CW
(30 GPM)
2" CW
(25 GPM)
4" HW
(230 GPM)
2" HW
(5 GPM)
2" HW
(5 GPM)
2" HW
(10 GPM)
2" HW
(15 GPM)
2" HW
(20 GPM)
2" HW
(25 GPM)
2" HW
(5 GPM)
2" HW
(5 GPM)
2" HW
(10 GPM)
2" HW
(15 GPM)
2" HW
(20 GPM)
2" HW
(5 GPM)
2" HW
(5 GPM)
2" HW
(10 GPM)
2" HW
(25 GPM)
2" HW
(30 GPM)
2" HW
(5 GPM)
2" HW
(10 GPM)
2" HW
(25 GPM)
2" HW
(20 GPM)
2" HW
(15 GPM)
2" HW
(10 GPM)
2" HW
(25 GPM)
2" HW
(20 GPM)
2" HW
(15 GPM)
2" HW
(10 GPM)
2" HW
(40 GPM)
2" HW
(20 GPM)
2" HW
(15 GPM)
2" HW
(10 GPM)
2" HW
(15 GPM)
2" HW
(20 GPM)
4" HW
(180 GPM)
2 1/2" HW
(65 GPM)
3" HW
(130 GPM)
2" HW
(25 GPM)
2" HW
(25 GPM)
2" HW
(35 GPM)
2" HW
(15 GPM)
2" HW
(20 GPM)
2" HW
(30 GPM)
2" HW
(25 GPM)
2" HW
(35 GPM) 2" CW
(40 GPM)
2" HW
(25 GPM)
2" CW
(30 GPM)
2" HW
(10 GPM)
2" HW
(15 GPM)
2" CW
(15 GPM)
2" CW
(20 GPM)
1/2" CA
1/2" CA
1/2" CA
1/2" CA
1/2" CA
1/2" CA
1/2" CA1/2" CA
1/2" CA
1/2" CA1/2" CA
1/2" CA
1/2" CA 1/2" CA
1/2" CA
1 1/2" CA
1 1/4" CA
1" CA 3/4" CA
4" HW
FILTER PIT SEWAGE
EJECTOR PIT
SI-1 SI-1
2" VENT THROUGH WALL WITH
DOWNWARD FACING ELBOW
(CORING BY PC)
FCO
FCO
FISH LAB
C-104
INVERT LAB
C-104B
ELECTRICAL
C-104A
INVERT LAB
C-104C
OFFICE
C-104D
DIAGNOSTIC LAB
C-104E
PREP/STORAGE
C-104F
R1
R2
R3
R4
R5
R6
R7
R8
R9
R10
R11
R12
R13
R14
R15
R16
R17
R18
R19
R20
R21
R22
R23
R24
R25
R26
R39
R38
R37
R36
R35
R34
R33
R32
R31
R30
R29
R28
R27
INSTALL PIPING BY EASTERN
WALL ABOVE EXISTING SILL
INSTALL PIPE ABOVE O.H.
DOOR OPENING
12"x12" XSA
FD-1
5 5
INFORMATION PERTAINING TO EXISTING PROJECT CONDITIONS, SUCH AS
LOCATIONS OF ARCHITECTURAL AND STRUCTURAL BUILDING COMPONENTS,
MECHANICAL AND ELECTRICAL EQUIPMENT, PIPING, DUCTWORK, ROUGH-INS AND
OTHER MISCELLANEOUS CONSTRUCTION, APPEARS ON PROJECT DRAWINGS.
THIS INFORMATION IS BASED ON AVAILABLE RECORDS AS WELL AS INFORMATION
COLLECTED WITH REASONABLE CARE AT THE PROJECT SITE. CONTRACTORS
SHALL BE SOLELY RESPONSIBLE FOR VERIFYING DIMENSIONS AND RELATED
INFORMATION AT THE PROJECT SITE PRIOR TO PROCURING ANY MATERIALS,
PRODUCTS OR EQUIPMENT TO PERFORM THEIR WORK.
EXISTING PROJECT CONDITIONS
SP-2
FILTER BANK PIT
SUMP CROCK
4" FILTERED
WATER
CONNECT TO
EXISTING DRAIN LINE
INSTALL BYPASS
GATE IN TRENCH
(SEE DETAIL 6/P501)
2" BACKWASH
EXISTING TRENCH DRAINS
SI-1
SP-1
P502
4" PUMP DISCHARGE
CONNECT DISCHARGE TO
SIDE OF TRENCH DRAIN.
(X) 4" UP TO TRENCH DRAIN
CONNECT TO TRENCH DRAIN
THROUGH SIDE OF TRENCH
3" SAN
NEW FD-1 WITH NO TRAP, FOR
FOOT-WASH DECONTAMINATION PADS.
CENTER IN AREA OF NEW SLOPED
SLAB RECESS
CURB TYPE VALVE
(X…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.