This is a product brochure for TrueNorth Steel's FIREGUARD® fire-rated above ground storage tanks. The document describes a double-wall tank system featuring an inner and outer steel tank with lightweight thermal insulation material that exceeds UL 2-hour fire testing requirements. FIREGUARD® tanks are UL 2085 listed "Protected" tanks and meet multiple regulatory standards including NFPA 30 & 30A, International Fire Code (IFC), California Air Resources Board (CARB) Standing Loss Control requirements, and Steel Tank Institute (STI) Standard F941. The tanks are compatible with a wide range of fuels and chemicals, including biodiesel and ethanol, with capacities ranging up to 30,000 gallons.

Key features include testable primary and secondary containment using standard on-site procedures, impermeable steel outer tanks resistant to cracking and weathering, interstitial space monitoring for leak detection capability, and support designs available for all seismic requirements. TrueNorth Steel supplies comprehensive accessories including FE Petro submersible pumps, dispenser platforms, overfill prevention valves, fill piping, fillboxes, OSHA ladders, stairs, walkways, and handrails. Cylindrical tank designs range from 186 to 30,000 gallons with outer dimensions and approximate weights provided. Rectangular tank options are available from 250 to 2,000 gallons. The document emphasizes advantages over concrete-encased alternatives, including lower maintenance costs, easier recyclability, lighter weight for transportation, and dual emergency venting systems. Contact information provided: 866-982-9511 or Tank@TrueNorthSteel.com.

View the file

Other files

Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FIREGUARD ®

FIRE-RATED ABOVE GROUND TANKS

WHY CHOOSE TRUENORTH STEEL’S UL 2085 FIREGUARD ?®

• SUSTAINABLE: Insulates product from ambient temperature variations, reducing environmental emissions

• TESTABLE: Primary and secondary tank can be tightness-tested on-site with standard testing procedures, unlike other designs

• COMPATIBLE: Primary storage tank and secondary containment compatible with a wide range of fuels and chemicals, including biodiesel and ethanol

Fireguard double-wall, fire-protected aboveground storage tanks feature an inner and outer steel tank with a unique, lightweight thermal insulation material that exceeds the UL 2-hour fire test.

• COST-EFFECTIVE: Steel outer wall provides low-cost maintenance and protection from weathering

• SUPPORTIVE: Support designs available for all seismic requirements

• MONITORABLE: Interstitial space can be monitored for leak detection

• DURABLE: Meets temperature requirements when the furnace test was extended to 4 hours

•UL 2085 listed “Protected” tank
•Ballistics and impact protection per UL 2085
•Both the inner and outer steel tanks are built to UL

standards

•National Fire Protection Association (NFPA) 30 & 30A
•International Fire Code (IFC)
•California Air Resources Board (CARB) Standing Loss

Control testing requirements for air emissions

• Steel Tank Institute (STI) Standard F941 for protected above ground storage tanks

•Capacities range up to 30,000 gallons
•Steel construction allows for recycling
•Low cost compartments and customization
•Built to nationally-recognized STI standards with

a strict third-party quality control inspection program

If your project is required to follow NFPA 30 or 30A guidelines, check with your “Authority Having Jurisdiction” related to maximum allowable tank capacity for the class fuel being stored and secondary containment requirements.

ADDITIONAL FEATURES:

THE ONLY TANK THAT MEETS ALL OF THESE STANDARDS

Unlike other manufacturers, TrueNorth Steel can supply accessories including FE Petro submersible pumps, dispenser platforms, overfill prevention valves and fill piping, fillboxes, OSHA ladders, stairs, walkways, and handrails.

LIGHTWEIGHT THERMAL INSULATION

• Unique feature that helped Fireguard exceed the UL 2-hour fire test

• Sufficiently porous to facilitate quick emergency venting and/or leak detection

STEEL PRIMARY TANK

STEEL SECONDARY TANK

• Built to UL 2085 standards

CONCRETE-ENCASEDvs.

Fireguard® is available from an extensive group of Steel Tank Institute fabricators who participate in the STI Quality Assurance Program. Under the program, independent quality control inspectors make unannounced visits to STI members, ensuring fabrication to the highest possible standards.

FIREGUARD

• Secondary containment is testable on-site using standard, economical testing procedures

• Impermeable, crack-resistant steel outer tank, which encloses the concrete-encased primary tank

• Steel secondary containment provides added strength and security, and is easily recycled

• Lightweight monolithic thermal insulation material Fireguard uses is a specialized concrete, part of a patented process resulting in a lighter-weight material than concrete alone

• Both primary and secondary tanks are fitted with emergency vents that will open in an emergency at a minimum pressure of 2.1 psi

• Secondary containment on certain designs may require elaborate and expensive procedures to be tested on-site

• Exposed concrete outer wall is susceptible to cracking, spalling, and weathering – expensive problems not typically covered by warranty

• Polyethylene sheeting depends on concrete for strength and takes years to decompose

• An average 12,000 gallon concrete-encased tank weighs approximately 100,000 pounds, increasing costs in transport-ing and future relocating

• Primary tank is fitted with an emergency vent, but secondary encasement is designed to fail in an emergency

FIREGUARD® SPECIFICATIONS

CYLINDRICAL DESIGN

OUTER TANK DIMENSIONS (inches)*

GALLONS DIAMETER LENGTH APPROX.

WEIGHT (lbs.)

186 48 54 1,750 250 48 68 2,100 300 50 72 2,350 500 60 76 3,100 560 60 84 3,350 1,000 70 78 3,800 1,500 70 114 5,500 2,000 70 150 6,500 2,500 70 186 7,900 3,000 70 222 9,000 4,000 90 174 12,300 5,000 102 168 13,750 6,000 102 198 15,500 8,000 102 258 20,000 10,000 102 330 24,500 12,000 102 390 28,000 15,000 126 312 34,500 20,000 126 414 39,500 25,000 126 516 49,000 30,000 126 618 74,000

FIREGUARD® SPECIFICATIONS

RECTANGULAR DESIGN

OUTER TANK DIMENSIONS (inches)*

GALLONS LENGTH WIDTH HEIGHT APPROX.

WEIGHT (lbs.)

450 44 44 55 2,100

3,100 2,800

500 140 51 36 4,800 750 140 72 35 6,100 1,000 1,000

4,300 3,800

1,500 124 88 43 5,400 2,000 2,000

6,300 6,100

*Dimensions and weights are sample sizes. Individual manufacturers may have alternate dimensions.

866-982-9511 | Tank@TrueNorthSteel.com TrueNorthSteel.com

0324 HG