Attachment 3 - Gas Sample Verification.xlsx

XLSX spreadsheet 48 KB Posted

Attached to
Compressed Gases Federal contract opportunity
Solicitation number
1305M326Q0071
Issued by
Department of Commerce National Oceanic and Atmospheric Administration

About this file

This is a gas sample verification attachment that establishes testing requirements and procedures for compressed gases submitted under solicitation 1305M326Q0071 for supply to the National Oceanic and Atmospheric Administration's Global Monitoring Laboratory in Boulder, Colorado.

The document specifies verification criteria for two gas types: Research-Grade Helium must demonstrate nitrogen concentrations below 3% and oxygen concentrations below 2% relative to mass 69, as measured by GCMS analysis at NOAA's lab; UHP Nitrogen must meet 99.999% purity specifications, be clean for use as a Nafion purge gas, be supplied in minimum 200 cubic foot high-pressure cylinders with a minimum fill pressure of 2000 psi, and include standard CGA fittings. Both gas types require submission of four samples for testing at NOAA's laboratory, with a minimum sample size of N200. Gases must be delivered no later than one week after the Government issues the request. Notably, contractors are prohibited from revising their quotations based on the results of this verification process, indicating that sample testing is a compliance and quality assurance measure rather than a negotiation point.

View the file

Other files for this federal contract opportunity

Other files attached to Compressed Gases, newest first.
File Type Posted
Sol_1305M326Q0071_Amd_0001.pdf PDF
Attachment 1 - Statement of Need (SON) Revision 1.pdf PDF
RFQ 1305M326Q0071 Industry Questions-Answers.pdf PDF
Attachment 2 - Pricing Schedule.xlsx XLSX spreadsheet
RFQ (CSS) 1305M326Q0071.pdf PDF
Attachment 1 - Statement of Need (SON).docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Gas Sample Requirements

Gas Sample Verification Instructions:
1. All submitted gases must meet the criteria listed below, including specification requirements, minimum sample size, and number of samples.
2. Gases must be delivered no later than one week after the Government has provided the request.
3. Your company will not be allowed to revise your quotation as a result of this verification.
Gas DescriptionSpecification RequirementsMinimum Sample SizeNumber of Samples
Research-Grade HeliumHave N2 concentrations below 3% and O2 concentrations below 2% relative to mass 69 (respectively) as measured by GCMS at NOAA labN2004 samples to test at NOAA lab
UHP NitrogenMeet 99.999% purity specs, Clean for multiple compound use as Nafion purge gas as tested by NOAA GCMS, Supplied in minimum 200 cu ft capacity high pressure cylinder, Have a minimum fill pressure of 2000 psi, Have standard CGA fittingsN2004 samples to test at NOAA lab

File details come from the government source that posted it. Updated .