Amendment_2.pdf
PDF 15 MB Posted
- Attached to
- Dixie National Forest SO Construction Federal contract opportunity
- Solicitation number
- 1284N819R0002
About this file
updated pages, Q&As, and reports
View the file
Other files for this federal contract opportunity
Show all 20
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
For the best experience, open this PDF portfolio in
Acrobat X or Adobe Reader X, or later.
Get Adobe Reader Now!
http://www.adobe.com/go/reader
Apr. 5, 2019 shillworthen
Typewritten Text s/s David Jeppsen 4/23/19
Polygonal Line
Rectangle
Text Box additive bid item area for secured parking lot.
Corrected 7/9/2019
Callout
Note 9, ALL ROUNDABOUT.
Apr. 5, 2019 s/s David Jeppsen 4/23/19
12'
18' corrected 7/9/2019
All Clear Environmental 1021 1038 W Industrial Rd
Cedar City, Utah
(435) 531-1337
ASBESTOS INSPECTION
REPORT
July1, 2019
REQUEST BY: Dixie National Forest Supervisor’s and
Cedar City Ranger District Office
Janice Parish: (702)559-3600
Email: soneil@fs.fed.us
INSPECTION SITE: 820 North Main Street
Cedar City Utah 84721
SCOPE OF WORK: An asbestos survey inspection was performed for the purpose of determining the presence of asbestos containing materials in a portion of a Commercial Building that will be demolition. A total of 6 samples were taken and sent to the laboratory for analysis.
RESULTS: The inspection site, built between 1940-1950 is a Commercial Building that will be demolish. Samples were collected in the big room, hallway, warehouse and boiler room. Samples consisted of the thermal systems insulation (TSI) pipe wrap. The overall condition of the samples were in fair condition. All 6 samples were sent to the laboratory for analysis. The laboratory report states that there was no asbestos detected.
July 1, 2019
SUSPECT MATERIALS THAT WILL BE REMOVED/DISTURBED
□ Thermal Systems Insulation (TSI) Pipe Wrap Unknown Sq. Ft.
ASSESSMENT:
Material Condition: All materials were in fair condition
Damage: No water damage was noted
Exposed surface area: Material was exposed and out in the open.
Accessibility: Material was easily accessible with ceilings 8’ & 20’ feet high.
Disclaimer: Additional suspect asbestos containing materials (ACM) may be identified during demolition or restoration that were not accessible during initial inspection. These should be addressed prior to continuing any work on the subject property.
SAMPLES TO LAB: All samples were shipped to EAS LLC, a US EPA approved lab.
Big Room
TSI
Pipe Wrap
Hallway
Boiler Room
Federal and state OSHA regulations for any asbestos containing materials require that workers follow
OSHA work practices and procedures, including respirator use and training.
CAUTION: One percent or more of asbestos is considered to be a hazardous substance and must be removed by a Utah
Division of Air quality-approved contractor, following US EPA approved procedures.
According to the US EPA:
1. Inhalation is the primary route of exposure for asbestos.
2. There is no known safe amount of asbestos exposure.
3. The more asbestos that you breathe in, the higher your risk of getting one of the three fatal
Asbestos-related diseases.
David Sean Riedl
David Sean Riedl - Utah Inspector Cert. ASB-6304
All Clear Environmental ASBC-612
1038 W Industrial Road, Cedar city Utah, 84721
(435) 531-6001 (cell) (435) 531-1337 (office)
Big Room Big Room
Big Room (3) Boiler Room
Boiler Room Boiler Room (3)
Front of Building Hallway
Sample 1 Sample 2 Sample 3
Sample 4 Sample 5 Sample 6
Warehouse (1) Warehouse (2)
Warehouse (3) Warehouse (4)
Warehouse (5)
Pre-Demolition Asbestos Inspection and Universal Waste and Hazardous
Materials Assessment U.S. Forest Service Compound
820 North Main Street
December 5, 2018
Terracon Project No. 61187469
Prepared for:
Case, Lowe, & Hart, Inc.
Ogden, Utah
Prepared by:
Terracon Consultants, Inc.
Midvale, Utah
Terracon Consul tants, Inc. 6949 South High Tech Dr ive M idvale, Utah 84047 P (801) 545-8500 F (801) 545-8600 terracon.com
Case, Lowe & Hart, Inc.
2484 Washington Boulevard, Suite 510 Ogden, Utah 84401
Attn: Ms. Rita Peterson P: [801] 399-5821 Ext. 12 E: ritap@clhae.com
Re: Pre-demolition Asbestos Inspections, Universal and Hazardous Waste Inspections, and Location of Oil-Water Separator Outfall U.S. Forest Service Compound 820 North Main Street
Dear Ms. Peterson:
The purpose of this report is to present the results of a pre-demolition asbestos survey, universal hazardous waste assessment, and oil-water separator outfall locate performed on November 14 and 15, 2018, at the above-referenced facility in Cedar City, Utah. This survey was conducted in accordance with Terracon Proposal Number P61187469, dated November 1, 2018. We understand that this survey was requested due to the future redevelopment of the site.
Asbestos-containing materials and universal waste/hazardous materials were identified during the assessment. Please refer to the attached report for details. Terracon appreciates the opportunity to provide this service to Case, Lowe, & Hart, Inc. If you have any questions regarding this report, or if you need any further assistance, please contact Michael Dunbar at (801) 545-9062.
Sincerely, Terracon Consultants, Inc.
Prepared by: Reviewed by:
Michael Dunbar, ASB 5752 Field Project Manager
J. Rush Bowers, CIH, CSP Senior Industrial Hygiene Consultant
Terracon Consultants ASB-289 mailto:ritap@clhae.com
TABLE OF CONTENTS
Page No.
1.0 INTRODUCTION
1.1 Project Objective
2.0 BUILDING / AREA DESCRIPTION
3.0 FIELD ACTIVITIES
3.1 Visual Assessment
3.2 Physical Assessment
3.3 Sample Collection
3.4 Sample Analysis
4.0 REGULATORY OVERVIEW
4.1 Asbestos
4.2 Hazardous Materials
5.0 FINDINGS AND RECOMMENDATIONS
5.1 Asbestos
5.2 Hazardous Materials
5.3 Oil-Water Separator Outfall Pipe
5.4 Inaccessible Areas
6.0 GENERAL COMMENTS
APPENDICES
Appendix A Asbestos Sample Location Drawing Appendix B Table 1 - Asbestos Testing Summary Table Appendix C Asbestos Laboratory Analytical Reports Appendix D Photo Log Appendix E Certifications Appendix F Estimated Asbestos-Containing Materials Removal Costs Appendix G Estimated Universal Waste and Hazardous Materials Removal Costs
Pre-Demolition Asbestos Survey, Universal Waste Assessment, and Location of Oil-Water Separator Outfall U.S. Forest Service Compound ■ Cedar City, Utah December 5, 2018 ■ Terracon Project No. 61187469
Resourceful ■ Responsive ■ Reliable 2
PRE-DEMOLITION ASBESTOS SURVEY,
UNIVERSAL WASTE ASSESSMENT, AND LOCATION OF OIL-WATER
SEPARATOR OUTFALL
Terracon No. 61187469
1.0 INTRODUCTION
Terracon Consultants, Inc. (Terracon) conducted an asbestos survey, universal waste assessment, and identified the location of the oil-water separator outfall at the U.S. Forest Service Compound, located at 820 North Main Street in Cedar City, Utah. The survey was conducted on November 14 and 15, 2018, by a State of Utah-certified Asbestos Inspector in accordance with Terracon Proposal Number P61187469, dated November 1, 2018. All observed materials were surveyed and homogeneous areas of suspect asbestos-containing materials (ACM) were visually identified and documented. Although reasonable effort was made to survey accessible suspect materials, additional suspect but un-sampled materials could be present in walls, in voids or in other concealed areas.
Samples of suspect ACM were collected to determine asbestos content. Sampling was performed in compliance with protocols outlined in United States Environmental Protection Agency (EPA) regulation 40 CFR 763, Asbestos Hazard Emergency Response Act (AHERA), and in accordance with the provisions of the Federal National Emission Standard for Hazardous Air Pollutants (NESHAP; 40 CFR 61, Subpart M). Upon collection, the samples were delivered to EMLab P&K in Phoenix, Arizona (National Voluntary Laboratory Accreditation Program (NVLAP) #500031-0), for analysis by polarized light microscopy (PLM), using EPA Method 600/R-93/116.
1.1 Project Objective
The objective of this project was to identify the presence or absence of asbestos, universal waste, and other hazardous materials present on the interior and exterior spaces of the building, and to locate the outfall pipe of the oil-water separator located in the maintenance building.
EPA regulation 40 CFR 61, Subpart M, NESHAP prohibits the release of asbestos fibers to the atmosphere during renovation or demolition activities. The asbestos NESHAP requires that regulated ACM be identified, classified and quantified prior to planned disturbances or demolition activities.
Responsive ■ Resourceful ■ Reliable 3
In compliance with federal guidelines, the following materials were visually identified and quantified:
n Mercury-vapor-containing fluorescent light bulbs n PCB-containing ballasts or transformers n Refrigeration units containing chlorofluorocarbons n Containers of liquid or hazardous waste n Suspect CFC-containing HVAC units n Air conditioning units n Compact fluorescent light bulbs (CFL)
The above-noted materials, if present, should be removed and disposed of or recycled should this building be demolished.
2.0 BUILDING / AREA DESCRIPTION
The U.S. Forest Service Compound consists of several vacant buildings. These buildings are a flammable materials storage shed, a sign shop, two shed/storage buildings, and the main maintenance/office building.
3.0 FIELD ACTIVITIES
The asbestos survey and universal waste assessment for the property at 820 North Main Street was conducted on November 14 and 15, 2018, by Mr. Michael Dunbar. Mr. Dunbar is a Utah-certified Asbestos Inspector. Copies of Mr. Dunbar’s most recent Asbestos Inspector refresher course certificate and license are attached as Appendix E.
3.1 Visual Assessment
Terracon began the asbestos sampling activities with a visual assessment and the identification and inventory of readily visible and accessible homogeneous areas of suspect ACM. A homogeneous area consists of materials that appear similar throughout in terms of color, texture and date of application. The interior assessment was conducted throughout visually accessible areas of the site. Materials identified as concrete, glass, wood, masonry, metal, plastic, or rubber were not considered suspect ACM.
3.2 Physical Assessment
A physical assessment of each homogeneous area of suspect ACM was conducted to assess the friability and condition of the materials. A friable material is defined by the EPA as a material that can be crumbled, pulverized or reduced to powder by hand pressure when dry. Friability was assessed by physically touching suspect materials.
Responsive ■ Resourceful ■ Reliable 4
3.3 Sample Collection
Based on results of the visual observation, bulk samples of suspect ACM were collected from the accessible interior and exterior building spaces. Bulk samples of suspect ACM were collected in accordance with AHERA sampling protocols, using wet methods as applicable to reduce the potential for fiber release. Samples were placed in sealable containers and labeled with unique sample numbers, using an indelible marker. Terracon collected 94 samples from 32 homogeneous areas of suspect ACM. Sampling location drawings are provided in Appendix A. Descriptions of the suspect materials, sample locations, and laboratory results are summarized in Table 1 located in Appendix B. Although reasonable effort was made to survey accessible suspect materials, additional suspect but un-sampled materials could be in walls, in voids, or in other concealed areas.
3.4 Sample Analysis
Samples of suspect ACM were delivered under standard chain-of-custody protocol to EMLab P&K (NVLAP #500031-0) in Phoenix, Arizona, for analysis by PLM, using EPA Method 600/R-93/116.
The percentage of asbestos, where applicable, was determined by microscopic visual estimation.
Copies of the analytical reports and chain-of-custody forms are provided in Appendix C.
4.0 REGULATORY OVERVIEW
4.1 Asbestos
The Utah Division of Air Quality (UDAQ) enforces the Asbestos NESHAP adopted by reference in Section 214-1, Utah Air Conservation Rules. The owner or operator must provide UDAQ with written notification at least 10 working days prior to the commencement of asbestos abatement activities that will disturb regulated asbestos-containing material (RACM) in amounts greater than or equal to 3 square feet or 3 linear feet.
The asbestos NESHAP (40 CFR Part 61, Subpart M) regulates asbestos fiber emissions and asbestos waste disposal practices. The asbestos NESHAP regulation also requires the identification and classification of existing ACM according to friability prior to demolition or renovation activity. Friable ACM is a material containing more than 1% asbestos that, when dry, can be crumbled, pulverized or reduced to powder by hand pressure. All friable ACM is considered
RACM.
The asbestos NESHAP regulation classifies ACM as either RACM, Category I non-friable ACM or Category II non-friable ACM. RACM includes all friable ACM, along with Category I and Category II non-friable ACM that has become friable, will be or has been subjected to sanding, grinding, cutting or abrading, or ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder during renovation or demolition activity. Category I non-friable ACM are exclusively asbestos-containing packings, gaskets, resilient floor coverings, resilient floor covering
Responsive ■ Resourceful ■ Reliable 5 mastics and asphalt roofing products that contain more than 1% asbestos. Category II non-friable ACM are all other non-friable materials other than Category I non-friable ACM that contain more than 1% asbestos. Category II non-friable ACM generally includes but is not limited to cementitious material such as cement pipes, cement siding, cement panels, glazing, mortar and grouts.
The United States Occupational Safety and Health Administration (OSHA) Asbestos Standard for Construction (29 CFR 1926.1101) regulates workplace exposure to asbestos. The OSHA standard requires that employee exposure to airborne asbestos must not exceed 0.1 fibers per cubic centimeter of air (0.1 f/cc) as an eight-hour time weighted average (TWA) and not exceed 1.0 fibers per cubic centimeter of air (1.0 f/cc) over a 30-minute time period known as an excursion limit (EL).
The TWA and EL are known as OSHA’s asbestos permissible exposure limits (PELs). The OSHA standard classifies construction and maintenance activities that could disturb ACM, and specifies work practices and precautions that employers must follow when engaging in each class of regulated work. The standard also specifies requirements for disturbing and handling materials with asbestos concentrations less than or equal to one percent.
4.2 Hazardous Materials
In compliance with federal guidelines the following materials were identified and quantified should any demolition be conducted as part of this project:
n Mercury-vapor-containing fluorescent light bulbs n PCB-containing ballasts or transformers n Refrigeration units containing chlorofluorocarbons n Containers of liquid or hazardous waste n Suspect CFC-containing HVAC units n Air conditioning units n Compact fluorescent light bulbs (CFL)
The above materials were visually identified, but no samples were collected for analysis.
5.0 FINDINGS AND RECOMMENDATIONS
5.1 Asbestos
Terracon collected 94 bulk samples from the site; based on the laboratory analytical reporting, three of the materials was identified as asbestos-containing material. The floor tile located in the maintenance building contained 2% Chrysotile, the joint compound of the gypsum board ceilings located in the maintenance building contained 2% Chrysotile, and the black roof tar located around roof penetrations of the maintenance building contained 15% Chrysotile. The floor tile located in the west shed by the south gate contained less than 1% chrysotile.
Responsive ■ Resourceful ■ Reliable 6
Resilient floor coverings and roofing materials are Category I Non-friable materials and do not have to be removed prior to demolition in accordance with the Utah Department of Air Quality and the EPA NESHAP rules and regulations. However, if these materials are to remain in the buildings during demolition, all demolition contractor personnel must be trained according to the requirements of the OSHA Asbestos standard for construction (29 CFR 1926.1101), the demolition would have to be performed in accordance with OSHA Class II removal requirements, and all of the demolition debris would have to be disposed of in sealed, leak-tight containers.
Therefore, Terracon recommends that these materials be removed by a certified abatement contractor prior to demolition.
Composite results of the wall system (drywall and joint compound) indicate that the system contains less than 1% asbestos and, therefore, is not regulated by EPA or Utah DAQ; however, the material must be removed following OSHA regulations. Terracon recommends that the wall system be removed and disposed of as an asbestos-containing material by certified abatement contractor prior to demolition.
The interior of the boiler in the maintenance building was not surveyed; therefore, suspect materials inside the boiler should be assumed to be asbestos-containing until tested and shown to be otherwise.
Material descriptions, locations, and sample results are summarized in Appendix B. Laboratory analytical reports are included in Appendix C.
5.2 Hazardous Materials
The following universal and hazardous waste materials were identified during this assessment:
n Approximately 364 4-foot fluorescent light tubes n Approximately 49 compact fluorescent lamps n Approximately 2 gallons of paint and 7 spray paint cans n Approximately 125 gallons of various chemicals n Approximately 2 suspect CFC-containing refrigeration units n Approximately 1 battery n Approximately 3 tires n Approximately 2 oil storage tanks n Approximately 2 hydraulic lifts n There is an unknown quantity of coal in the boiler room.
The noted materials above should be disposed of or recycled in accordance with all local, state, and federal regulations.
Responsive ■ Resourceful ■ Reliable 7
5.3 Oil-Water Separator Outfall Pipe
On November 15, 2018, Mr. Rooter Plumbing of St. George located the outfall pipe of the oil-water separator located in the maintenance building. The outfall pipe was traced using a camera system with a transmitter that locates the camera inside the pipe. The oil-water separator is located in the south west corner of the maintenance building. The outfall pipe runs south out of the building to the nearby manhole and turns west towards Main Street. Blockages in the pipe prevented the camera from traveling further west. It is believed that the outfall pipe either turns into the sewer line near the manhole cover or continues parallel to the sewer line and runs into Main Street. If more information is required on the location of the outfall pipe, the blockages will need to be cleared, such as by hydro-blasting.
5.4 Inaccessible Areas
The outfall pipe from the oil-water separator had a blockage near the manhole cover south of the maintenance building, which the camera system could not get past.
The interior of the boiler located in the maintenance building was not inspected and may contain asbestos.
6.0 GENERAL COMMENTS
This survey was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions and recommendations expressed in this report are based on conditions observed during our survey of the building. The information contained in this report is relevant to the date on which this survey was performed and should not be relied upon to represent conditions at a later date. This report has been prepared on behalf of and exclusively for use by the Case, Lowe, & Hart, Inc. for specific application to their project as discussed. This report is not a bidding document. Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories or other third parties supplying information which may have been used in the preparation of this report. No warranty, express or implied, is made.
APPENDIX A
ASBESTOS SAMPLE LOCATION DRAWING
APPENDIX B
ASBESTOS TESTING SUMMARY TABLE
Cedar City, Utah 84721
ASBESTOS SURVEY SAMPLE LOCATION SUMMARY
Homogenous Area
Sample No. Description Sample Location Quantity Lab Results
Fire Storage
87469-1
Gray concrete Exterior west wall
600 sq.ft. ND87469-2 Exterior east wall north 87469-3 Exterior west wall south
87469-4
White paint Exterior west wall
600 sq.ft. ND87469-5 Exterior north wall 87469-6 Exterior south wall
87469-7
White window glazing North window
3 ln.ft. ND87469-8 South window 87469-9 South window
87469-10
Brown paper Interior north wall
560 sq.ft. ND87469-11 Interior north wall 87469-12 Interior north wall
87469-13
Black underlayment Roof
260 sq.ft. ND87469-14 Roof 87469-15 Roof
Sign Shop
87469-16
Gray window glazing West bay south side
1,680 ln.ft. ND87469-17 Center bay south side 87469-18 East bay east side
87469-19
Brown mill board 2nd floor center bay
130 sq.ft. ND87469-20 2nd floor center bay 87469-21 2nd floor center bay
87469-22 White 12”x12” floor tile with brown streaks and adhesive
East bay north 425 sq.ft. ND87469-23 East bay center
87469-24 East bay south
87469-25
Stored windows in east bay
8 windows ND87469-26 Stored windows in east
87469-27 Stored windows in east
87469-28 White 2’x4’ ceiling tile with worm burrow pattern
East bay north 425 sq.ft. ND87469-29 East bay center
87469-30 East bay south
87469-31 White 1’x1’ ceiling tile with medium and small pin holes
East bay stored in box 30 sq.ft. ND87469-32 East bay stored in box
87469-33 East bay stored in box
87469-34
Exterior east side
2,200 sq.ft. ND87469-35 Exterior west side 87469-36 Exterior south side
87469-37
Exterior east side
2,200 sq.ft. ND87469-38 Exterior west side 87469-39 Exterior south side
87469-40
Black rolled roofing with gray pebbles
Exterior 1,971 sq.ft. ND87469-41 Exterior
87469-42 Exterior
87469-43
Black rolled roofing with red pebbles
Exterior 1,971 sq.ft. ND87469-44 Exterior
87469-45 Exterior
87469-46
Black rolled tar paper with shiny side
2nd floor east bay 60 sq.ft. ND87469-47 2nd floor east bay
87469-48 2nd floor east bay Sheds
87469-49
White drywall Shed
455 sq.ft. ND87469-50 Shed 87469-51 Shed
87469-52
White ceiling texture
119 sq.ft. ND87469-53 Shed 87469-54 Shed
87469-55 Green 12”x12” floor tile with white streaks and mastic
119 sq.ft.
<1% chrysotile in tile only 87469-56 Shed 87469-57 Shed
87469-58
Black roof underlayment Roof
120 sq.ft. ND 87469-59 Roof
87469-60
Black asphalt roofing Wood shed roof
94 sq.ft. ND87469-61 Wood shed roof Maintenance Shop
87469-62
Exterior west side
8,000 sq.ft. ND87469-63 Exterior south side 87469-64 exterior east side
87469-65
Maintenance bay NEC
5,520 ln.ft. ND87469-66 Sign room 87469-67 South center room
87469-68
White ceiling texture Maintenance bay office
413 sq.ft. ND87469-69 Maintenance bay office 87469-70 Maintenance bay office
87469-71 Green 12”x12” floor tile with white streaks and mastic
498 sq.ft.
2%
87469-72 Maintenance bay office 87469-73 Restroom
87469-74
Drywall ceilings
Hall
814 sq.ft.
2% joint compound
87469-75 Maintenance bay office
87469-76 SW office near sign room
87469-77
Exterior west side
8,000 sq.ft. ND87469-78 Exterior south side 87469-79 Exterior east side
87469-80 Black asphalt roof shingles with gray pebbles
South side roof center 364 sq.ft. ND87469-81 South side roof east
87469-82 South side roof west
87469-83
Black built up tar roofing and gravel
Office roof 224 sq.ft. ND87469-84 Office roof
87469-85 Office roof
87469-86 Black rolled asphalt roofing with gray pebbles
Roof north side 364 sq.ft. ND87469-87 Roof north side
87469-88 Roof north side
87469-89
Black painted plaster Boiler room
625 sq.ft. ND87469-90 Boiler room 87469-91 Boiler room
87469-92
Black roof tar Maintenance roof
20 sq.ft 15% chrysotile87469-93 Maintenance roof
87469-94 Office roof
Key:
sq. ft. = square feet ln. ft. = linear feet ND = none detected
APPENDIX C
ASBESTOS LABORATORY ANALYTICAL REPORT
Approved by:
Approved Signatory Renee Luna-Trepczynski
Report for:
Michael Dunbar Terracon Consultants, Inc. - Utah 6949 S. High Tech Drive, Suite 100 Midvale, UT 84047
Regarding: Project: 61187469; Forrest Service Compound
EML ID: 2045984
All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the items tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.
EMLab P&K ("the Company") shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.
Dates of Analysis:
Asbestos PLM: 11-21-2018 and 11-23-2018
Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EM-AS-S-1267)
EMLab ID: 2045984, Page 1 of 28Aerotech Laboratories, Inc
EMLab P&K 1501 West Knudsen Drive, Phoenix, AZ 85027
(800) 651-4802 Fax (623) 780-7695 www.emlab.com Client: Terracon Consultants, Inc. - Utah C/O: Michael Dunbar Re: 61187469; Forrest Service Compound
Date of Receipt: 11-19-2018 Date of Report: 11-23-2018
ASBESTOS PLM REPORT
Total Samples Submitted: 94 Total Samples Analyzed: 94
Total Samples with Layer Asbestos Content > 1%: 7
Location: 87469-1, Gray Concrete Lab ID-Version‡: 9659209-1
Sample Layers Asbestos Content Gray Concrete with White Paint ND
Sample Composite Homogeneity: Good
Location: 87469-2, Gray Concrete Lab ID-Version‡: 9659210-1
Location: 87469-3, Gray Concrete Lab ID-Version‡: 9659211-1
Location: 87469-4, White Paint Lab ID-Version‡: 9659212-1
EMLab ID: 2045984, Page 2 of 28Aerotech Laboratories, Inc
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".
Location: 87469-5, White Paint Lab ID-Version‡: 9659213-1
Location: 87469-6, White Paint Lab ID-Version‡: 9659214-1
Location: 87469-7, White Window Glazing Lab ID-Version‡: 9659215-1
White Window Glazing ND
Location: 87469-8, White Window Glazing Lab ID-Version‡: 9659216-1
EMLab ID: 2045984, Page 3 of 28Aerotech Laboratories, Inc
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
Location: 87469-9, White Window Glazing Lab ID-Version‡: 9659217-1
Location: 87469-10, Brown Paper Lab ID-Version‡: 9659218-1
Brown Paper with Black Coating ND
Composite Non-Asbestos Content: 85% Cellulose
Location: 87469-11, Brown Paper Lab ID-Version‡: 9659219-1
Location: 87469-12, Brown Paper Lab ID-Version‡: 9659220-1
EMLab ID: 2045984, Page 4 of 28Aerotech Laboratories, Inc
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
Location: 87469-13, Black Underlayment Lab ID-Version‡: 9659221-1
Black Paper (Underlayment) ND
Composite Non-Asbestos Content: 80% Cellulose
Location: 87469-14, Black Underlayment Lab ID-Version‡: 9659222-1
Location: 87469-15, Black Underlayment Lab ID-Version‡: 9659223-1
Location: 87469-16, Gray Window Glazing Lab ID-Version‡: 9659224-1
Gray Window Glazing with Tan Paint ND
EMLab ID: 2045984, Page 5 of 28Aerotech Laboratories, Inc
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
Location: 87469-17, Gray Window Glazing Lab ID-Version‡: 9659225-1
Gray Window Glazing ND
Location: 87469-18, Gray Window Glazing Lab ID-Version‡: 9659226-1
Gray Window Glazing with Red Paint ND
Location: 87469-19, Brown Mill Board Lab ID-Version‡: 9659227-1
Brown Fibrous Material (Mill Board) ND
Composite Non-Asbestos Content: 90% Cellulose Sample Composite Homogeneity: Moderate
Location: 87469-20, Brown Mill Board Lab ID-Version‡: 9659228-1
EMLab ID: 2045984, Page 6 of 28Aerotech Laboratories, Inc
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
Location: 87469-21, Brown Mill Board Lab ID-Version‡: 9659229-1
Location: 87469-22, White 12"X12" Floor Tile W/Brown Streaks & Adhesive Lab ID-Version‡: 9659230-1
White Floor Tile ND Yellow Adhesive ND
Location: 87469-23, White 12"X12" Floor Tile W/Brown Streaks & Adhesive Lab ID-Version‡: 9659231-1
Location: 87469-24, White 12"X12" Floor Tile W/Brown Streaks & Adhesive Lab ID-Version‡: 9659232-1
EMLab ID: 2045984, Page 7 of 28Aerotech Laboratories, Inc
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
Location: 87469-25, White Window Glazing Lab ID-Version‡: 9659233-1
White Window Glazing with Multilayered Paint ND
Location: 87469-26, White Window Glazing Lab ID-Version‡: 9659234-1
Location: 87469-27, White Window Glazing Lab ID-Version‡: 9659235-1
Location: 87469-28, White 2'X4' Ceiling Tile W/Worn Burrow Pattern Lab ID-Version‡: 9659236-1
White Ceiling Tile with White Surface ND
EMLab ID: 2045984, Page 8 of 28Aerotech Laboratories, Inc
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
Location: 87469-29, White 2'X4' Ceiling Tile W/Worn Burrow Pattern Lab ID-Version‡: 9659237-1
Location: 87469-30, White 2'X4' Ceiling Tile W/Worn Burrow Pattern Lab ID-Version‡: 9659238-1
Location: 87469-31, White 1'X1' Ceiling Tile W/Medium & Small Pinholes Lab ID-Version‡: 9659239-1
Location: 87469-32, White 1'X1' Ceiling Tile W/Medium & Small Pinholes Lab ID-Version‡: 9659240-1
EMLab ID: 2045984, Page 9 of 28Aerotech Laboratories, Inc
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
Location: 87469-33, White 1'X1' Ceiling Tile W/Medium & Small Pinholes Lab ID-Version‡: 9659241-1
Location: 87469-34, Gray Concrete Lab ID-Version‡: 9659242-1
Location: 87469-35, Gray Concrete Lab ID-Version‡: 9659243-1
Location: 87469-36, Gray Concrete Lab ID-Version‡: 9659244-1
EMLab ID: 2045984, Page 10 of 28Aerotech Laboratories, Inc
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
Location: 87469-37, White Paint Lab ID-Version‡: 9659245-1
Location: 87469-38, White Paint Lab ID-Version‡: 9659246-1
Location: 87469-39, White Paint Lab ID-Version‡: 9659247-1
White Paint ND
Location: 87469-40, Black Rolled Roofing W/Gray Pebbles Lab ID-Version‡: 9659248-1
Black Roofing Material (Rolled Roofing) with Gray Pebbles ND
Composite Non-Asbestos Content: 10% Cellulose
EMLab ID: 2045984, Page 11 of 28Aerotech Laboratories, Inc
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
Location: 87469-41, Black Rolled Roofing W/Gray Pebbles Lab ID-Version‡: 9659249-1
Location: 87469-42, Black Rolled Roofing W/Gray Pebbles Lab ID-Version‡: 9659250-1
Location: 87469-43, Black Rolled Roofing W/Red Pebbles Lab ID-Version‡: 9659251-1
Black Roofing Tar and Felt with Red Pebbles ND
Composite Non-Asbestos Content: 40% Cellulose
Location: 87469-44, Black Rolled Roofing W/Red Pebbles Lab ID-Version‡: 9659252-1
EMLab ID: 2045984, Page 12 of 28Aerotech Laboratories, Inc
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
Location: 87469-45, Black Rolled Roofing W/Red Pebbles Lab ID-Version‡: 9659253-1
Location: 87469-46, Black Rolled Tar Paper W/Shiny Side Lab ID-Version‡: 9659254-1
Black Tar Paper with Shiny Side ND
Composite Non-Asbestos Content: 70% Cellulose
Location: 87469-47, Black Rolled Tar Paper W/Shiny Side Lab ID-Version‡: 9659255-1
Location: 87469-48, Black Rolled Tar Paper W/Shiny Side Lab ID-Version‡: 9659256-1
EMLab ID: 2045984, Page 13 of 28Aerotech Laboratories, Inc
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
Location: 87469-49, White Drywall Lab ID-Version‡: 9659257-1
White Texture with White Paint ND
Cream Tape ND White Joint Compound ND
White Drywall with Brown Paper ND Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Poor
Location: 87469-50, White Drywall Lab ID-Version‡: 9659258-1
Location: 87469-51, White Drywall Lab ID-Version‡: 9659259-1
Location: 87469-52, White Ceiling Texture Lab ID-Version‡: 9659260-1
White Ceiling Texture with White Paint ND
Brown Fibrous Material ND Composite Non-Asbestos Content: 5% Cellulose
EMLab ID: 2045984, Page 14 of 28Aerotech Laboratories, Inc
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
Location: 87469-53, White Ceiling Texture Lab ID-Version‡: 9659261-1
Location: 87469-54, White Ceiling Texture Lab ID-Version‡: 9659262-1
Location: 87469-55, Green 12"X12" Floor Tile W/White Streaks & Mastic Lab ID-Version‡: 9659263-1
Green Floor Tile < 1% Chrysotile Yellow Mastic ND
Location: 87469-56, Green 12"X12" Floor Tile W/White Streaks & Mastic Lab ID-Version‡: 9659264-1
EMLab ID: 2045984, Page 15 of 28Aerotech Laboratories, Inc
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
Location: 87469-57, Green 12"X12" Floor Tile W/White Streaks & Mastic Lab ID-Version‡: 9659265-1
Location: 87469-58, Roof Underlayment, Black Lab ID-Version‡: 9659266-1
Black Roofing Material ND
Location: 87469-59, Roof Underlayment, Black Lab ID-Version‡: 9659267-1
Black Roofing Material ND
Location: 87469-60, Black Asphalt Roofing W/Gray Pebbles Lab ID-Version‡: 9659268-1
Black Roofing Tar and Felt with White Pebbles ND
Black Roofing Felt ND
EMLab ID: 2045984, Page 16 of 28Aerotech Laboratories, Inc
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
Location: 87469-61, Black Asphalt Roofing W/Gray Pebbles Lab ID-Version‡: 9659269-1
Location: 87469-62, Concrete Gray Lab ID-Version‡: 9659270-1
Location: 87469-63, Concrete Gray Lab ID-Version‡: 9659271-1
Location: 87469-64, Concrete Gray Lab ID-Version‡: 9659272-1
EMLab ID: 2045984, Page 17 of 28Aerotech Laboratories, Inc
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
Location: 87469-65, White Window Glazing Lab ID-Version‡: 9659273-1
Gray Window Glazing with Off-White Paint ND
Location: 87469-66, White Window Glazing Lab ID-Version‡: 9659274-1
Location: 87469-67, White Window Glazing Lab ID-Version‡: 9659275-1
Location: 87469-68, White Ceiling Texture Lab ID-Version‡: 9659276-1
White Ceiling Texture with Beige Paint ND
EMLab ID: 2045984, Page 18 of 28Aerotech Laboratories, Inc
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. EMLab P&K reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.