3. Project Drawings - Scenic Byway Recreation Site Rehab - UPDATED 6-20.pdf
PDF 5 MB Posted
- Solicitation number
- 127EAW25R0024
- Issued by
-
Department of Agriculture Forest Service
About this file
The provided file contains project drawings for the GAOA Scenic Byway Recreation Site Rehabilitation project in the Sierra National Forest, created by the United States Department of Agriculture Forest Service. The comprehensive set of 28 detailed engineering and site plans covers multiple campgrounds and vista sites, including Fish Creek, Soda Springs, Bowler, Goat Meadow, Redinger Overlook, Ross Cabin, Mile High, Arch Rock, Jackass Meadows, Portuguese, Cold Springs, and Fresno Dome locations.
The drawings specify extensive site improvements including installing double and single vault toilet buildings, constructing stamped concrete outdoor recreation access routes (ORARs), installing rock-lined ditches and dissipaters, creating hardened aggregate surfaces, adding signage, constructing parking spurs, installing picnic tables and fire rings, implementing rock and post barriers, and protecting existing natural features. The project documents are dated between 10/18/2024 and 6/20/2025, with multiple revision dates, and appear to be part of a federal contract opportunity valued between $5-10 million, set aside for total small business participation.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT LOCATION
VICINITY MAP
TRAVEL DIRECTIONS:
SHEET OF
United States Department of Agriculture
Forest Service
001 028
From North Fork, CA. head East on Rd. 225, at the traffic circle take the second exist and stay on Rd 225. Travel approximately 4.1 mile and merge with the NFSR 4S18 "Minarets Road", continue for 2.3 miles and destination is on left (GPS Coordinates 37.179612, -119.434262)
SEE ATTACHED MAP
RECOMMENDED BY:
APPROVED:
FOREST ENGINEER
DISTRICT RANGER DATE
DATE
DIRECTOR OF ENGINEERING
DATE
FOREST SUPERVISOR DATE
DATE
RO FACILITIES PROGRAM MANAGER
GAOA SCENIC BYWAY REHABILITATION PROJECT
CALIFORNIA
MADERA COUNTY
SIERRA NATIONAL FOREST
(R05) PACIFIC SOUTHWEST
INDEX OF SHEETS
SHEET SHEET TITLE DATE
01 COVER SHEET 6/20/2025
G-1 FISH CREEK CAMPGROUND 6/20/2025
G-2 SODA SPRINGS CAMPGROUND 6/20/2025
G-3 BOWLER CAMPGROUND 6/20/2025
G-4 GOAT MEADOW 6/20/2025
G-5 SIGN DETAILS 6/20/2025
G-6 ROAD AND PARKING DETAILS 10/18/2024
G-7 CAMPSITE DETAILS 10/18/2024
G-8 CAMPSITE FURNITURE DETAILS 10/18/2024
G-9 SIGN DETAILS 2 10/18/2024
G-10 OUTDOOR RECREATION ACCESS ROUTES 10/18/2024
G-11 TRASH ENCLOSURE AND DUMPSTER DETAILS 10/18/2024
G-12 BARRIER AND FEE TUBE DETAILS 10/18/2024
G-13 DRAINAGE DETAILS 10/18/2024
G-14 PLACER CAMPGROUND SITE PLAN 10/18/2024
G-15 SWEET WATER CAMPGROUND SITE PLAN 10/18/2024
G-16 WAGNER CAMPGROUND SITE PLAN 10/18/2024
G-17 LITTLE JACKASS CAMPGROUND SITE PLAN 6/20/2025
G-18 REDINGER OVERLOOK SITE PLAN 10/18/2024
G-19 ROSS CABIN SITE PLAN 10/18/2024
G-20 MILE HIGH SITE PLAN 6/20/2025
G-21 ARCH ROCK SITE PLAN 10/18/2024
G-22 JACKASS MEADOW VISTA SITE PLAN 10/18/2024
G-23 PORTUGUESE VISTA SIGN PLAN 6/20/2025
G-24 COLD SPRINGS SITE PLAN 10/18/2024
G-25 FRESNO DOME SITE PLAN 6/20/2025
G-26 SINGLE VAULT TOILET BUILDING DETAILS 10/18/2024
G-27 DOUBLE VAULT TOILET BUILDING DETAILS 10/18/2024
S
G-05
NOTES:
1. BEST ATTEMPTS HAVE BEEN MADE TO LOCATE
ALL EXISTING CONSTRUCTED FEATURES TO
BE REMOVED. HOWEVER, ADDITIONAL ITEMS
MAY REQUIRE DEMOLITION AS DIRECTED BY
THE FOREST SERVICE.
2. THE LOCATION OF THE EXISTING AND
PROPOSED CONSTRUCTED FEATURES SHOWN
IS APPROXIMATE. THE FINAL LOCATION OF ALL
CONSTRUCTED FEATURES SHALL BE
DETERMINED IN THE FIELD BY THE FOREST
SERVICE IN COORDINATION WITH THE
CONTRACTOR.
3. SEE THE TECHNICAL SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
4. ONLY A SMALL SECTION OF THE EXISTING AND
PROPOSED BARRIERS IS SHOWN AS A
REPRESENTATION. THE BARRIERS SHALL BE
INSTALLED ALONG THE ROAD AND PARKING
PER DETAIL 3/G-6. THE CONTRACTOR SHALL
FIELD VERIFY THE QUANTITY OF THE
BARRIERS.
5. THE DRAINAGE DIRECTION, GRADES, AND
SLOPES SHALL BE COORDINATED IN THE
FIELD BETWEEN THE CONTRACTOR AND THE
FOREST SERVICE TO AVOID EROSION ISSUES.
6. THE PROPOSED DRAINAGE STRUCTURES ARE
APPROXIMATE AND NEED TO BE FIELD
VERIFIED BY THE CONTRACTOR.
G-9
INSTALL STOP SIGN
(TOTAL 1 EA)
CONSTRUCT TRASH ENCLOSURE AND
INSTALL DUMPSTER (TOTAL 1 EA)
R
O
A
D
G-11
G-5
G-5
INSTALL CAMPSITE MARKER (TYP.)
(TOTAL 4 EA)
INSTALL FOOD LOCKER (TYP.)
(TOTAL 4 EA)
G-8
CONSTRUCT SINGLE CAMPSITE (TYP.)
(TOTAL 4 EA - 450 SQ.FT/EACH) INCLUDING
TENT PAD (TOTAL 4 EA - 250 SQ.FT/EACH)
ADD ADDITIONAL 1' TO ACCOMMODATE POST
BARRIERS WHERE LIVING AREA ABUTS BACK
END OF PARKING SPUR TO PREVENT VEHICLE
OVERHANG (TYP.)
S I T
E
S I T
E
S I T
E
S
I
T
E
INSTALL PICNIC TABLE (TYP.)
(TOTAL 4 EA)
INSTALL HORIZONTAL POST BARRIERS TO ALLOW
VEHICLE OVERHANG (TYP.)
G-12
INSTALL AGGREGATE BASE PULLOFF
G-8
INSTALL FIRE RING (TYP.)
(TOTAL 4 EA)
PROTECT EXISTING CREEK
INSTALL AGGREGATE BASE PARKING SPURS (TYP.)
(TOTAL 4 EA)
G-12
INSTALL FEE TUBE (TYP.)
(TOTAL 1 EA)
REMOVE AND DISPOSE EX. ENTRANCE SIGN AND
INSTALL NEW ENTRANCE SIGN (TOTAL 1 EA)
INSTALL 22' WIDE DOUBLE LANE ROAD WITH
AGGREGATE BASE SURFACE ROAD
G-6
G-6
R
R
Y
P
R
Y
P
D-7
G-8
G-10
ROCKLINED DITCH AND DISSIPATER SHOWN FOR
REFERENCE ONLY. NOT PART OF THIS CONTRACT.
(TYP.)
DOUBLE VAULT TOILET BUILDING .
CONSTRUCT STAMPED CONCRETE
ORAR
INSTALL PANEL BULLETIN BOARD
M
I
N
M
I
N
G-6
G-7
INSTALL "ONE-WAY" SIGN
G-9
G-27
SINGLE VAULT TOILET BUILDING .
CONSTRUCT STAMPED CONCRETE
ORAR
G-10
G-26
INSTALL PRESSURE TREATED POSTS
G-12
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
(R05)
PACIFIC SOUTHWEST REGION
GAOA SCENIC
BYWAY -
CAMPGROUNDS
SIERRA NATIONAL
FOREST
BASS LAKE
RANGER DISTRICT
FISH CREEK
CAMPGROUND
SITE PLAN
10/30/2024
CESAR S.
CESAR S.
ANTONIO C.
G-01 2 28
RFI 6/20/2025
RFI #1 &4 .
RFI #3
RFI #2
RFI #7
RFI #7
NOTES:
1. BEST ATTEMPTS HAVE BEEN MADE TO LOCATE ALL
EXISTING CONSTRUCTED FEATURES TO BE REMOVED.
HOWEVER, ADDITIONAL ITEMS MAY REQUIRE DEMOLITION
AS DIRECTED BY THE FOREST SERVICE.
2. THE LOCATION OF THE EXISTING AND PROPOSED
CONSTRUCTED FEATURES SHOWN IS APPROXIMATE. THE
FINAL LOCATION OF ALL CONSTRUCTED FEATURES SHALL
BE DETERMINED IN THE FIELD BY THE FOREST SERVICE IN
COORDINATION WITH THE CONTRACTOR.
3. SEE THE TECHNICAL SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
4. ONLY A SMALL SECTION OF THE EXISTING AND PROPOSED
BARRIERS IS SHOWN AS A REPRESENTATION. THE
BARRIERS SHALL BE INSTALLED ALONG THE ROAD AND
PARKING SPURS PER DETAIL 3/G-6. THE CONTRACTOR
SHALL FIELD VERIFY THE QUANTITY OF THE BARRIERS.
5. THE DRAINAGE DIRECTION, GRADES, AND SLOPES SHALL
BE COORDINATED IN THE FIELD BETWEEN THE
CONTRACTOR AND THE FOREST SERVICE TO AVOID
EROSION ISSUES.
6. THE PROPOSED DRAINAGE STRUCTURES ARE
APPROXIMATE AND NEED TO BE FIELD VERIFIED BY THE
CONTRACTOR.
EXISTING BULLETIN BOARD, REMOVE AND
DISPOSE REMNANTS AND ALL RELATED
COMPONENTS (TOTAL 1 QTY)
EXISTING SIGN, REMOVE AND DISPOSE REMNANTS
AND ALL RELATED COMPONENTS (TYP.)
(TOTAL 1 QTY)
EXISTING DUMPSTER, REMOVE AND DISPOSE
REMNANTS AND ALL RELATED COMPONENTS (TYP.)
EXISTING BULLETIN BOARD, REMOVE AND
DISPOSE REMNANTS AND ALL RELATED
COMPONENTS (TOTAL 1 QTY)
EXISTING DUMPSTER, REMOVE AND DISPOSE
REMNANTS AND ALL RELATED COMPONENTS (TYP.)
INSTALL CAMPSITE MARKER (TYP.),
REMOVE AND DISPOSE EXISTING
(TOTAL 18 QTY)
ROAD 04S081
INSTALL STOP SIGN
(TOTAL 1 EA)
G-9
INSTALL ENTRANCE SIGN
(TOTAL 1 EA)
G-5
22'
S
I
FURNISH AND INSTALL A DOUBLE
VAULT TOILET BUILDING
CONSTRUCT STAMPED CONCRETE ORAR (TYP.).
G-10
G-6
G-5
INSTALL AGGREGATE BASE PULLOFF
INSTALL 2-PANEL BULLETIN BOARD
(TOTAL 1 EA)
S I T
E
G-12
INSTALL FEE TUBE (TYP.)
(TOTAL 1 EA)
S I T
E
S
I
S
I
I
I
I
I
I T
E
S I T
E
S
I
S
I
S
I
S
I
S
I
S
I
S
I
INSTALL AGGREGATE BASE
PARKING SPURS (TYP.)
(TOTAL 18 EA)
INSTALL AGGREGATE BASE SURFACE ROAD
(TYP.) - 12FT SINGLE AND 22' DOUBLE LANE
G-6
CONSTRUCT TRASH ENCLOSURE AND
INSTALL DUMPSTER (TYP.)
G-11
INSTALL HORIZONTAL BARRIER AT END OF
PARKING SPUR TO PREVENT VEHICLE
OVERHANG (TYP.)
INSTALL PICNIC TABLE (TYP.)
(TOTAL 18 EA)
G-8
INSTALL FIRE RING (TYP.)
(TOTAL18 EA)
G-8
INSTALL FOOD LOCKER (TYP.)
(TOTAL 18 EA)
G-8
CONSTRUCT SINGLE CAMPSITE W/TENT PAD
(TOTAL 18 EA - 700 SQ.FT. UNLESS SIZE
INCREASES DUE TO ADDITIONAL SPACE FOR
BARRIERS)
G-7
ROCKLINED DITCH AND DISSIPATER
G-5
REMOVE AND DISPOSE EXISTING PICNIC
TABLES AND REMNANTS AND ALL RELATED
COMPONENTS (TYP.) (TOTAL 18 QTY)
G-6
G-12
INSTALL "ONE-WAY" SIGN (TOTAL 1 EA)
G-9
INSTALL "CAMPING UNIT" SIGN
G-9
REMOVE AND DISPOSE EXISTING FIRE RINGS AND
REMNANTS AND ALL RELATED COMPONENTS (TYP.)
(TOTAL 18 QTY)
INSTALL 24" CULVERT, 40' LNFT.
G-13
INSTALL ROCKLINED DITCH (TOTAL 80LF) AND
DISSIPATER (TOTAL 1 EA)
G-13
G-13
G-27
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
(R05)
PACIFIC SOUTHWEST REGION
GAOA SCENIC
BYWAY -
CAMPGROUNDS
SIERRA NATIONAL
FOREST
BASS LAKE
RANGER DISTRICT
SODA SPRINGS
CAMPGROUND
SITE PLAN
10/30/2024
CESAR S.
CESAR S.
ANTONIO C.
G-02 3 28
RFI 6/20/2025
RFI #8.
RFI #9.
EXISTING CONSTRUCTED FEATURES TO BE REMOVED.
HOWEVER, ADDITIONAL ITEMS MAY REQUIRE DEMOLITION
AS DIRECTED BY THE FOREST SERVICE.
2. THE LOCATION OF THE EXISTING AND PROPOSED
CONSTRUCTED FEATURES SHOWN IS APPROXIMATE. THE
FINAL LOCATION OF ALL CONSTRUCTED FEATURES SHALL
BE DETERMINED IN THE FIELD BY THE FOREST SERVICE IN
COORDINATION WITH THE CONTRACTOR.
3. SEE THE TECHNICAL SPECIFICATIONS FOR ADDITIONAL
INFORMATION.
4. ONLY A SMALL SECTION OF THE EXISTING AND PROPOSED
BARRIERS IS SHOWN AS A REPRESENTATION. THE
BARRIERS SHALL BE INSTALLED ALONG THE ROAD AND
PARKING SPURS PER DETAIL 3/G-6. THE CONTRACTOR
SHALL FIELD VERIFY THE QUANTITY OF THE BARRIERS.
5. THE DRAINAGE DIRECTION, GRADES, AND SLOPES SHALL
BE COORDINATED IN THE FIELD BETWEEN THE
CONTRACTOR AND THE FOREST SERVICE TO AVOID
EROSION ISSUES.
6. THE PROPOSED DRAINAGE STRUCTURES ARE
APPROXIMATE AND NEED TO BE FIELD VERIFIED BY THE
CONTRACTOR.
R
O
A
D
S
CONSTRUCT DOUBLE CAMPSITE (TYP.)
(TOTAL 11 EA - 650 SQ.FT/CAMPSITE TYP.
UNLESS SIZE INCREASES DUE TO
ADDITIONAL SPACE FOR BARRIERS)
G-7
INSTALL PICNIC TABLE (TYP.)
(TOTAL 22 EA)
G-8
G-8
S
I
I
I
I
I
I
I
I
I
S
I
ADD ADDITIONAL 1' TO ACCOMMODATE POST
BARRIERS WHERE LIVING AREA ABUTS BACK
END OF PARKING SPUR TO PREVENT VEHICLE
OVERHANG (TYP.)
INSTALL FIRE RING (TYP.)
(TOTAL 22 EA)
G-8
INSTALL FOOD LOCKER (TYP.)
(TOTAL 22 EA)
WHEN THE CAMPSITES ARE NOT ON BACK
END OF PARKING SPURS, INSTALL
HORIZONTAL POST BARRIERS TO ALLOW
VEHICLE OVERHANG (TYP.).
G-10
INSTALL CAMPSITE MARKER (TYP.)
(TOTAL 11 EA)
G-5
G-5
CONSTRUCT TRASH ENCLOSURE
AND DUMPSTER (TOTAL 1 EA)
G-11
S I T
E
CONSTRUCT 22' WIDE DOUBLE LANE ROAD
WITH AGGREGATE BASE SURFACE
G-6
CONSTRUCT 12' WIDE SINGLE LANE ROAD WITH
AGGREGATE BASE SURFACE
G-6
INSTALL ROCK AND POST BARRIERS
G-12
ROCKLINED DITCH AND DISSIPATER SHOWN FOR
REFERENCE ONLY. NOT PART OF THIS CONTRACT.
INSTALL 1-PANEL BULLETIN BOARD
(TOTAL 1 EA)
FURNISH AND INSTALL A DOUBLE
VAULT TOILET BUILDING
CONSTRUCT STAMPED CONCRETE ORAR
(TYP.) (TOTAL 130 SQ.FT)
G-12
INSTALL ENTRANCE SIGN
(TOTAL 1 EA)
G-5
INSTALL STOP SIGN
(TOTAL 1 EA)
G-9
INSTALL AGGREGATE BASE PARKING SPURS (TYP.)
(TOTAL 11 EA)
G-6
G-7
INSTALL "ONE-WAY" SIGN
(TOTAL 1 EA)
G-9
G-27
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
(R05)
PACIFIC SOUTHWEST REGION
GAOA SCENIC
BYWAY -
CAMPGROUNDS
SIERRA NATIONAL
FOREST
BASS LAKE
RANGER DISTRICT
BOWLER GROUP
CAMPGROUND
SITE PLAN
10/30/2024
CESAR S.
CESAR S.
ANTONIO C.
G-03 4 28
RFI 6/20/2025
RFI #10.
M
R
A
Y
M
O
N
R
O
A
D
G-27
INSTALL ROCK DISSIPATER (TYP.)
G-13
INSTALL ROCKLINED DITCH UNDER ROOF
LINE OF TOILET BUILDING AND SLOPE TO
DRAIN WITH NATURAL TOPOGRAPHY AWAY
FROM SITE AMENITIES
G-13
CONSTRUCT STAMPED CONCRETE ORAR.
SEE NOTE 2.
FURNISH AND INSTALL ENTRANCE SIGN.
SEE NOTE 3.
NOTES:
1. THE FINAL LOCATION OF THE TOILET BUILDING
AND ROCKLINED DITCH SHALL BE DETERMINED IN
THE FIELD BY THE FOREST SERVICE IN
COORDINATION WITH THE CONTRACTOR.
2. THE STAMPED CONCRETE ORAR SHALL HAVE A 2%
SLOPE IN ANY DIRECTION ON THE 5FT LANDING
OUTSIDE OF THE TOILET BUILDING AND UP TO AN
8.33% RUNNING SLOPE ON THE ORAR LEADING TO
THE LANDING.
3. FINISH GRADE AROUND ENTRANCE SIGN SHALL
HAVE A 2% SLOPE IN ANY DIRECTION WITHIN 5FT
ALL AROUND.
4. SEE THE TECHNICAL SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
INSTALL DOUBLE VAULT TOILET BUILDING
(TOTAL 1 EA)
G-10
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
(R05)
PACIFIC SOUTHWEST REGION
GAOA SCENIC
BYWAY -
CAMPGROUNDS
SIERRA NATIONAL
FOREST
BASS LAKE
RANGER DISTRICT
GOAT MEADOW
SITE PLAN
10/30/2024
CESAR S.
CESAR S.
ANTONIO C.
G-04 5 28
RECESSED NUT DETAIL FOR
1/2" CARRIAGE BOLTS THAT
CONNECT THE 8"X8" POSTS
TOGETHER.
ENTRANCE SIGN 1
G-5
NTS
NOTES:
1. THE RECYCLED PLASTIC RECREATION SITE SIGNS, USDA CREDIT
LINES, AND SHIELDS SHALL BE MANUFACTURED BY
WOOD PRODUCT SIGNS ROUTED RECYCLE PLUS, INC.,
4890 COUNTY ROAD 76, PARLIN, CO 81239. (970)641-1675.
www.woodproductsigns.com. OR APPROVED EQUAL BY THE
FOREST SERVICE.
2. THE MAXIMUM SPACE BETWEEN THE 3"X6" CROSSPIECE BOARDS
SHOULD BE NO MORE THAN 3-1/2" FEET.
3. ALL HOLES DRILLED MUST BE OVERSIZED A MINIMUM OF 1/8" TO
1/4" THAN THE BOLT USED. THIS IS TO PREVENT THE SIGN FROM
CRACKING.
4. BOLTS AND FASTENERS SHOULD BE LOOSELY FASTENED TO
ALLOW MOVEMENT OF EXPANSION OR CONTRACTION OF THE
HDPE RECYCLED PLASTIC SIGN MATERIAL.
5. ALL ROUND HEAD CARRIAGE BOLTS SHALL BE GALVANIZED.
PAINTED SURFACE SHALL BE ETCHED PRIOR TO PAINTING.
6. ALL BOLTS AND METALS SHALL BE PAINTED IN ACCORDANCE
WITH SECTION 09900. COLOR SHALL BE "DARK CHOCOLATE"
UNLESS DIRECTED OTHERWISE BY THE FOREST SERVICE. APPLY
TWO COATS OF PRIMER AND TWO COATS OF DIRECT TO METAL
PAINT TO ALL METAL AND HARDWARE. PRIMER SHALL BE "PRO
INDUSTRIAL DTM PRIMER".
7. THE FINAL LOCATION OF THE ENTRANCE SIGN SHALL BE
DETERMINED IN THE FIELD BY THE FOREST SERVICE IN
COORDINATION WITH THE CONTRACTOR.
8. FINISH GRADE SLOPE SHALL NOT EXCEED 2% IN ANY DIRECTION.
SINGLE SIGN INSTALLATION (USDA CREDIT LINE AND RECREATION SITE SIGN)
SINGLE SIGN INSTALLATION (SHIELD)
63"
8"
55"
40"
6"
5'-6"
6'-6"
8'-0"
1'-0"
10'
9'
1 1/2"
U.S. DEPARTMENT OF AGRICULTURE
2'-6"
R=7"
3"X6" TREATED D.F CROSS
BAR W/ JOIST HANGERS SHALL
BE PAINTED IN ACCORDANCE
WITH SECTION 09900. COLOR
SHALL BE "DARK CHOCOLATE"
OR APPROVED EQUAL BY THE
FOREST SERVICE.
1/2" ROUND HEAD
CARRIAGE BOLTS.
COUNTERSUNK AND
RECESSED NUT.
(1) USDA CREDIT LINES "P-43,
5-1/2"X43" RECYCLED PLASTIC"
BOLTED TO 2"X4" CROSS BAR W/
3/8" ROUND HEAD CARRIAGE
BOLTS
8"x8" CEDAR POSTS W/ 1"
45° CHAMFER EDGES.
APPLY A CLEAR STAIN.
ALIGN POST PARALLEL TO
SIGNS. REFERENCE NOTE
11 IN DETAIL 4/G-3.
(1) SHIELD "S-12, 12"
RECYCLED PLASTIC" BOLTED
TO POSTS W/ 3/8" ROUND
HEAD CARRIAGE BOLTS. TO
BE INSTALLED ON POST
CLOSEST TO ROAD.
(1) RS-2 RECYCLED
PLASTIC SIGN, SEE
BELOW.
FRONT ELEVATION
SECTION VIEW
PLAN VIEW
LEVEL FINISHED GRADE AROUND SIGN
AND MULCH ALL DISTURBED AREAS
32"
COMPACTED
NATIVE SOIL
NATIVE SOIL
COMPACTED
NATIVE SOIL
NATIVE SOIL
1/2"
2'-6" 1'-0"
18"
80°
RS-2 SIGN DIMENSIONS
(1) RS-2 RECYCLED
PLASTIC SIGN, SEE
BELOW
(1) USDA CREDIT
LINES "P-43, 5-1/2"X43"
RECYCLED PLASTIC"
BOLTED TO 2"X4"
CROSS BAR W/ 3/8"
ROUND HEAD
CARRIAGE BOLTS
4'
4"
18"
BREAKAWAY HOLES
3" SIZE. (TYP.)
EX. ROAD
1/4" MAX.
2" X 4" TREATED D.F. CROSS
BAR WITH JOIST HANGERS
CAMPGROUND
SIERRA
1) POST
8" X 8"
2) GALV. CARRIAGE BOLT
3/8" (CREDIT LINE)
3/8" (SITE SIGN)
3) GALV. WASHER
4) SIGN PANEL
5-1/2"X43"X3/4" (CREDIT LINE)
40" X
63" X
3/4" (SITE SIGN)
5) GALV. WASHERS
6) CROSSPIECE BOARDS
2"X4" (CREDIT LINE)
3"X6" (SITE SIGN)
7) JOIST HANGERS
8) GALV. NUT
1) POST
8" X
8"
2) GALV. CARRIAGE BOLT
3/8"
3) GALV. WASHER
4) SIGN PANEL
12" SHIELD
5) GALV. WASHERS
6) GALV. NUT
BULLETIN BOARD
G-5
NTS
SIGN INSTALLATION
1) 6" X
6" POST
2) 3/8" X
5" GALV.
CARRIAGE BOLT
3) GALV. WASHER
4) 5/8" HOLE DRILLED
THROUGH SIGN PANEL
5) SIGN PANEL
48" X 48"
X 3/4"
6) GALV. WASHERS
7) GALV. NUT
8) JOIST HANGERS
9) 3"X6" CROSS BAR
10) RECESS (OPTIONAL)
NOTES:
1. SUGGESTED VENDOR IS :
WOOD PRODUCT SIGNS ROUTED RECYCLE PLUS, INC., 4890 COUNTY ROAD 76, PARLIN, CO
81239. (970) 641-1675 www.woodproductsigns.com OR APPROVED EQUAL BY THE FOREST
SERVICE.
2. ALL HOLES DRILLED MUST BE OVERSIZED A MINIMUM OF 1/8" TO 1/4" THAN THE BOLT USED. THIS
IS TO PREVENT THE SIGN FROM CRACKING.
3. BOLTS AND FASTENERS SHOULD BE LOOSELY FASTENED TO ALLOW MOVEMENT OF EXPANSION
OR CONTRACTION OF THE HDPE RECYCLED PLASTIC SIGN MATERIAL.
4. ALL BOLTS AND METALS SHALL BE PAINTED IN ACCORDANCE WITH SECTION 09900. PAINTED
SURFACES SHALL BE ETCHED PRIOR TO PAINTING. COLOR SHALL BE "DARK CHOCOLATE"
UNLESS DIRECTED OTHERWISE BY THE FOREST SERVICE. APPLY TWO COATS OF PRIMER AND
TWO COATS OF DIRECT TO METAL PAINT TO ALL METAL AND HARDWARE. PRIMER SHALL BE "PRO
INDUSTRIAL DTM PRIMER".
5. THE FINAL LOCATION OF THE BULLETIN BOARDS SHALL BE DETERMINED IN THE FIELD BY THE
FOREST SERVICE IN COORDINATION WITH THE CONTRACTOR.
7. FINISH GRADE SLOPE SHALL NOT EXCEED 2% IN ANY DIRECTION AND SHALL BE FLUSH WITH THE
OUTDOOR RECREATION ACCESS ROUTES (ORARS) FOR ACCESSIBILITY.
8. TITLES ON HEADERS AND FOOTERS SHALL BE AS SHOWN ON THE DRAWINGS.
INFORMATION
SIERRA
48"
PANELS NOTES:
1. EACH PANEL SHALL BE MADE OF RECYCLED HDPE PLASTIC
3/4" THICK, STANDARD F.S. "BROWN" COLOR..
2. EACH PANEL SHALL HAVE A 6" HEADER. HEADERS SHALL
CONTAIN TITLES AS SHOWN IN 3" TEXT. HEADERS SHALL BE
STANDARD F.S. "YELLOW-CREAM" COLOR BACKGROUND W/
RAISED "BROWN" COLOR LETTERS.
3. EACH PANEL SHALL HAVE A 6" FOOTER. FOOTERS SHALL
HAVE NAME OF FOREST (SIERRA NATIONAL FOREST).
FOOTERS SHALL BE STANDARD F.S. "YELLOW-CREAM" COLOR
BACKGROUND W/ 3" RAISED "BROWN" COLOR LETTERS.
FOOTER
HEADER
48"
6"
6"
BOWLER
U-SHAPED HOT-DIP GALVANIZED JOIST
HANGERS SIZED FOR ROUGH SAWN LUMBER.
SECURE WITH SIMPSON #SD 9 CONNECTOR
SCREWS. FACE SCREW USING 1
" SCREWS.
TOE SCREW USING 2
" SCREWS.
#9 - 1
" SCREWS
TYP
#9 - 2
" SCREWS
#9 - 1
" SCREWS
TYP
#9 - 2
" SCREWS
U-SHAPED HOT-DIP GALVANIZED JOIST
HANGERS SIZED FOR ROUGH SAWN LUMBER.
SECURE WITH SIMPSON #SD 9 CONNECTOR
SCREWS. FACE SCREW USING 1
" SCREWS.
TOE SCREW USING 2
" SCREWS.
CAMPSITE MARKER
NTS
FRONT VIEW
SIDE VIEW
3'-0"
3'-0"
1'-6"
6"
6"
6'-0"
3'-0"
1'-6"
6"
3"
5"
ATTACH 5-1/2" REFLECTIVE
ALUMINUM CAMPSITE
MARKER SIGNS TO 60° ON
CAMPSITE MARKER POST,
SEE SIGN DETAIL ABOVE.
GALVANIZED STEEL CLIP,
FASTEN WITH LOWER MARKER
NAIL , PAINT PER SECTION 09900
NOTE 7
NOTES 3 AND 11
NOTES:
1. CAMPSITE MARKERS HEIGHT SHALL BE
MEASURED FROM THE TOP OF ROAD
ADJACENT TO THE MARKER.
2. ATTACH SIGN TO CAMPSITE MARKER POST
WITH (2) 1/8"x2-1/2" STAINLESS STEEL TAMPER
PROOF SCREWS.
3. SIGN SHALL HAVE 3M HIGH INTENSITY
PRISMATIC WHITE BACKGROUND, COVERED
WITH FOREST SERVICE FEDERAL SPEC
BROWN.
4. MARKER POST SHALL BE SET 2' MIN FROM
EDGE OF ROAD AND PARKING SPUR.
5. REFERENCE SIGN AND POST INSTALLATION
NOTES, DETAIL 6/G-9.
5-1/2"
5-1/2"
1/2"
1/4"
3/16" HOLE
2'
MIN
EDGE OF
ROAD
3'-0"
6'-0"
2'
MIN
TOP OF
ROAD
8 3"
G-5
NOTE 5
AND 6
CAMPGROUND
SIERRA
CAMPGROUND
SIERRA
FISH CREEK
SODA SPRINGS
4"
4'-0"
7'-0"
3'-0"
10'-0"
SIERRA
6"
6"
1'-6"
4'-1" (TYP.)
2'-8"
COMPACTED NATIVE SOIL
NATIVE SOIL
6"X6" POST
1'-0"
1'-0"
5'-0"
PLAN VIEW
FRONT ELEVATION
7'-0"
2% SLOPE IN ANY DIRECTION
2' RADIUS
WELCOME
EDGE OF ORAR
10"
3'-0"
G-10
CONSTRUCT STAMPED COLORED
CONCRETE
CONSTRUCT HARDENED AGGREGATE
SURFACE 12" BEYOND LIMIT OF
CONCRETE
G-10
11'-6"
7' LANDING AT SINGLE PANEL AND
11'-6" AT TWO PANEL BULLETIN
BOARDS
SIERRA
2'-8"
1" - 45° CHAMFER
JOIST HANGER
3"X6" DOUGLAS FIR
CROSS BAR
3/4" RECYCLED PLASTIC SINGLE
PANEL, SEE BELOW
6"X6"X10' DOUGLAS FIR POSTS. PRESSURE
TREATED. STAIN IN ACCORDANCE WITH
SECTION 09900. COLOR SHALL BE "DARK
CHOCOLATE" OR APPROVED EQUAL BY
FOREST SERVICE.
INFORMATION
ONLY THE WELCOME SIGN APPLIES
TO LOCATIONS WHERE 1-PANEL
BULLETIN BOARD IS SPECIFIED
WELCOME
SIERRA
48"
FOOTER
HEADER
48"
6"
6"
TROUGH
30"
14"
4'
3'-0'
4'-6"
3'-0"
1'-6"
6"
6"
7'-6"
2'
MIN
EP
NOTES:
1. THE FINAL CONTENT, ARROW DIRECTION, AND SIGN
SIZES TO BE APPROVED BY THE FOREST SERVICE
DURING THE SUBMITTAL PROCESS.
2. SIGN SHALL BE 14"X30"X3/4" RECYCLED PLASTIC SIGN
W/ 3" ROUTED LETTERS AND BORDER IN
'YELLOW-CREAM COLOR' ON 'BROWN' BACKGROUND
WITH 3/8" ROUTED BORDER
3 AND 11
G-9
G-9
TROUGH SIGN
NTS
G-5
G-9
G-9
G-9
G-9
6"
MEADOW
GOAT
SIERRA
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
(R05)
PACIFIC SOUTHWEST REGION
GAOA SCENIC
BYWAY -
CAMPGROUNDS
SIERRA NATIONAL
FOREST
BASS LAKE
RANGER DISTRICT
SIGN DETAILS
10/30/2024
CESAR S.
CESAR S.
ANTONIO C.
G-05 6 28
RFI 06/20/2025
G-6
R=30' TYP.
VARIES,
R=5' TYP.
L
N
G
13' WIDE
HORIZONTAL BARRIER OR POST
BARRIERS, SEE PLAN FOR LAYOUT
LIVING AREA AND TENT PAD,
SEE PLAN SHEETS FOR LAYOUT
ROCK AND POST BARRIERS,
SEE PLAN FOR LAYOUT
VARIES 30°-60°, SEE PLAN
S
P
CAMPSITE MARKER TO BE ALIGNED
WITH START OF CURVE RADIUS
AND BARRIER POSTS. CAMPSITE
MARKER NUMBER SHALL FACE THE
ROAD.
(TYP.)
CONSTRUCTION STA POINT
15' LONG X 13' WIDE
SEE PLAN
AS SHOWN ON PLAN
ROAD
DRIVEWAY
PARKING AREA
4" AGGREGATE BASE
COURSE ROAD
COMPACTED NATIVE
SOIL/UNDISTURBED
NATIVE OR
STRUCTURAL FILL
EX. TREE
EX. TREE
1' AGGREGATE SHOULDER (TYP.)
TRAFFIC FLOW
PROFILE
PLAN VIEW
FINISHED GRADE, 3: 1 TYP.,
2:1 MAX. SLOPE
USE ROCK BARRIERS AS SHOWN AT
PARKING SPURS TO HOLD CORNERS
NOTES:
1. SEE PLAN SHEETS FOR LAYOUT OF PARKING SPURS, LIVING AREAS, TENT PADS, ROCKS, POSTS AND HORIZONTAL
BARRIERS.
2. CONSULT FOREST SERVICE REPRESENTATIVE FOR FINAL GRADES AND SLOPES.
3. THE RADIUS OF THE INTERIOR ANGLE OF THE PARKING SPUR SHALL TYPICALLY BE 5'. HOWEVER, WHERE IMPRACTICAL
THE RADIUS SHALL BE 2' MIN.
4. WHERE THE LIVING AREA IS ADJACENT TO A PARKING SPUR, THE SURFACE OF THE LIVING AREA SHALL BE FLUSH WITH
THE SURFACE OF THE PARKING SPUR.
5. CAMPSITE MARKER SHALL BE LOCATED ON OUTER RADIUS ON PULL IN PARKING SPURS. SEE PLANS FOR CAMPSITE
MARKER LOCATIONS.
6. THE RUNNING SLOPE OF DRIVEWAYS SHALL BE NO MORE THAN 8.33% FOR NO MORE THAN 50 FEET. THE CROSS-SLOPE
ON DRIVEWAYS SHALL NOT EXCEED 3%. THE SLOPE OF THE PARKING AREA SHALL NOT EXCEED 2% IN ANY DIRECTION.
WHERE SITE CONDITIONS ALLOW, THE SLOPE OF PARKING SPURS (BOTH THE DRIVEWAY AND PARKING AREA) SHALL
NOT EXCEED 2% IN ANY DIRECTION.
EXCEPTION 1: A RUNNING SLOPE OF UP TO 10% FOR DRIVEWAYS IS PERMITTED FOR UP TO 30 FEET.
EXCEPTION 2: IF EXCEPTION 1 CANNOT BE MET BECAUSE ONE OR MORE CONDITIONS FOR DEPARTURE IN
SECTION 1.1 OF FSORAG EXISTS, A RUNNING SLOPE OF NO MORE THAN 10% IS PERMITTED FOR NO MORE THAN
50 FEET.
7. WHERE TERRAIN DOES NOT ALLOW FOR A 30-60 DEG ANGLE, DESIGN A WIDER OUTSIDE RADIUS INTO THE DRIVEWAY
OF THE PARKING SPUR TO FACILITATE PARKING.
8. WHERE TERRAIN, VEGETATION, AND NATURAL FEATURES SUCH AS CREEKS DOES NOT ALLOW FOR THE 40' LENGTH OF
PARKING SPURS, CONSTRUCT LONGEST LENGTH FEASIBLE WITH A 25' LENGTH MINIMUM. DESIGN 13' WIDE AT SINGLE
PARKING SPURS AND 24' WIDE AT DOUBLE PARKING SPURS.
9. THE FINAL LOCATION, ANGLE, AND DIMENSIONS OF THE PARKING SPURS SHALL BE DETERMINED IN THE FIELD BY THE
FOREST SERVICE IN COORDINATION WITH THE CONTRACTOR.
G-5
G-8
G-8
SEE PLAN
G-8
20'-22' WIDE 25' LONG X 13' WIDE
FINISHED GRADE, 3: 1 TYP.,
2:1 MAX. SLOPE
1% MIN, 2% MAX
PARKING SPUR
NTS
G-7
2'
M
IN
.3
M A
X
S E
E N
O T
E
AGGREGATE BASE ROAD SECTION
G-6
NTS
NOTES:
1. WITHIN THE 2' CLEARING, ONLY REMOVE
VEGETATION DESIGNATED FOR REMOVAL ON THE
PLANS OR THAT MAY BE A HAZARD TO VEHICULAR
TRAFFIC.
2. THE CROWN IN THE ROAD SURFACE MAY BE
REQUIRED FOR PROPER DRAINAGE. FOREST
SERVICE REPRESENTATIVE AND CONTRACTOR TO
FIELD VERIFY.
2% CROSS SLOPE
2'
EXISTING SLOPE
PROPOSED GRADING TO
MEET EXISTING SLOPE
2:1 MAX
PROPOSED GRADING TO
MEET EXISTING SLOPE
2:1 MAX
EXISTING SLOPE
4" COMPACTED AGGREGATE
SURFACE COURSE, GRADING
D TO 95%
1' AGGREGATE
SHOULDER
(2' AT CULVERT
CROSSING)
CLEARING WIDTH
C
L E
A R
I N
G
H
E I G
H T
SEE PLAN FOR ROADWAY WIDTHS
1' AGGREGATE SHOULDER AT 5% SLOPE
(2' AT CULVERT CROSSING).
12' SINGLE LANE
20' MIN. - 22' MAX. DOUBLE LANE
COMPACTED NATIVE SOIL/UNDISTURBED NATIVE
OR STRUCTURAL FILL (ACCEPTED NATIVE)
COMPACTED TO 92%
ROADWAY WIDTH
PLUS 1' EACH SIDE
2'
(SEE PLAN FOR SLOPE DIRECTION)
G-9
ROCK LINED DITCH MAY APPLY,
FOREST SERVICE REP AND
CONTRACTOR TO FIELD VERIFY
20'-40'
AS MARKED ON PLAN
10' MIN 10' MIN
CAMPGROUND ROAD
AS SHOWN ON PLAN
12' OR 22'
18'R
OR AS SHOWN
ON LAYOUT PLAN
18'R
OR AS SHOWN
ON LAYOUT PLAN
18'R
OR AS SHOWN
ON LAYOUT PLAN
18'R
OR AS SHOWN
ON LAYOUT PLAN
EP
EP
CONSTRUCTION STA.
POINT
G-6
TYPICAL PULLOFF
NTS
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
(R05)
PACIFIC SOUTHWEST REGION
GAOA SCENIC
BYWAY -
CAMPGROUNDS
SIERRA NATIONAL
FOREST
BASS LAKE
RANGER DISTRICT
ROAD AND
PARKING SPUR
DETAILS
10/30/2024
CESAR S.
CESAR S.
ANTONIO C.
G-06 7 28
DOUBLE CAMPSITE
D-7
NTS
SINGLE CAMPSITE
D-7
4' MIN.
4' MIN.
5' TYP.
4' MIN.
4' MIN.
5' TYP.
4' MIN.
7' TYP.
4' MIN.
4' MIN.
5' TYP.
4' MIN.
4' MIN.
5' TYP.
4' MIN.
7' TYP.
4' MIN.4' MIN.
EX. TREE
EX. TREE
EX. TREE
EX. ROCK
EX. ROCK
5' TYP.
5' TYP.
(2) FOOD LOCKERS,
SEE PLANS FOR LOCATION
FOOD LOCKER, SEE
PLANS FOR LOCATION
16' TYP.
16' TYP. 18' TYP.
25' TYP.
16' TYP.
16' TYP.
25' TYP.
25' TYP.
16' TYP.
16' TYP.
HARDENED
AGGREGATE
SURFACE
TENT PAD
SEE PLANS
FOR
LOCATION
LIVING AREA
FIRE RING
PICNIC TABLE
G-10
D-8
D-8
D-8
COMPACTED NATIVE SOIL,
SCARIFY 3", REMOVE ROCKS, LEVEL
AND RE-COMPACT TO STABILIZE
TENT PAD
SEE PLANS
FOR
LOCATION
LIVING AREA
(2) FIRE RINGS
(2) PICNIC TABLES
D-8
D-8
COMPACTED NATIVE SOIL,
SCARIFY 3", REMOVE ROCKS,
LEVEL AND RE-COMPACT TO
STABILIZE
REQUIRED CLEAR SPACE:
NATURAL OBJECTS MAY BE INCORPORATED
INTO THE CAMPSITE LIVING SPACE AND
TENT PAD, AS LONG AS THE MINIMUM 4 FT
OF CLEAR SPACE IS MAINTAINED AROUND
THE PICNIC TABLE AND FIRE RING.
TENT PAD
SEE PLANS
FOR
LOCATION
COMPACTED NATIVE SOIL,
SCARIFY 2"-3", REMOVE ROCKS,
LEVEL AND RE-COMPACT TO
STABILIZE
D-8
NOTES:
1. LIVING AREAS, PICNIC TABLES, FIRE RINGS, FOOD LOCKERS, AND TENT PADS SHALL BE CONSTRUCTED AS SHOWN ON THE PLANS AND AS APPROVED IN THE FIELD BY THE FOREST SERVICE REPRESENTATIVE.
2. LIVING AREAS AND TENT PADS SHALL BE STABILIZED AND GRADED WITH SLOPE TO DRAIN WITH NATURAL TOPOGRAPHY, BUT NOT EXCEED 2% IN ANY DIRECTION.
3. RETAIN EXISTING VEGETATION WHEN IT DOES NOT CONFLICT WITH GRADING.
4. MAINTAIN A 5 FT. MINIMUM HORIZONTAL DISTANCE AND A 20 FT. MINIMUM VERTICAL DISTANCE BETWEEN CAMPFIRE RING AND VEGETATION.
5. GRADE SO RUNOFF WATER SHEET DRAINS ACROSS LIVING AREAS AND TENT PADS.
6. ADJUST PERIMETER OF THE SITE AS NEEDED TO ACCOMMODATE MINIMUM CLEARANCES SHOWN ON THE DRAWINGS.
7. TENT PADS SHALL BE CONSTRUCTED ADJACENT TO LIVING AREAS, HOWEVER DUE TO SITE RESTRICTIONS, TENT PADS MAY BE SEPARATED FROM THE LIVING AREA AND CONNECTED TO THE LIVING AREA BY A GRADED HARDENED AGGREGATE TRAIL.
8. LIVING AREAS SHALL BE CONSTRUCTED ADJACENT TO PARKING SPURS, HOWEVER DUE TO SITE RESTRICTIONS, SOME LIVING AREAS MAY BE CONSTRUCTED AWAY FROM PARKING SPURS AND THEN CONNECTED WITH A GRADED HARDENED AGGREGATE
TRAIL AS REQUIRED.
9. AT SINGLE CAMPSITES, CONTRACTOR TO INSTALL (1) ANIMAL PROOF FOOD LOCKER, (1) UNIVERSAL ACCESS PICNIC TABLE AND (1) CAMPFIRE RING AT EACH SITE.
10. AT DOUBLE CAMPSITES, CONTRACTOR SHALL INSTALL (2) ANIMAL PROOF FOOD LOCKERS, (2) UNIVERSAL ACCESS PICNIC TABLES AND (2) CAMPFIRE RINGS AT EACH SITE.
11. CUT OR FILL SLOPES SHALL NOT EXCEED 2:1
12. ALL SINGLE SITE LIVING AREAS WILL BE A MINIMUM OF 450 SQ FT., AND ALL DOUBLE SITE LIVING AREAS SHALL BE A MINIMUM OF 650 SQ FT UNLESS NATURAL OBJECTS ARE INCORPORATED THAT CHANGE THE SQUARE FOOTAGE WHILE STILL MAINTAINING
ALL REQUIRED MINIMUM CLEAR SPACES.
13. ALL TENT PADS WILL BE A MINIMUM OF 256 SQ FT.
14. EDGE OF CLEARING LIMITS - 18" MIN. FROM THE EDGE OF TENT PADS AND LIVING AREAS.
15. IF SITE CONDITIONS DO NOT ALLOW THE FOOD LOCKERS TO BE LOCATED AT THE LOCATIONS SHOWN ON THE PLANS, LOCATE THE FOOD LOCKERS AWAY FROM THE TENT PADS TO THE EXTENT POSSIBLE FOR SAFETY.
NTS
PLAN VIEW
PLAN VIEW
TENT PAD/LIVING AREA SECTION VIEW
:1
T Y
P
Y
P
2% SLOPE MAX
TENT PAD
EXISTING SLOPE
EXISTING SLOPE
FINISHED GRADE
(TYP)
EX. TREE
AS SHOWN ON PLANS
LIVING AREA
4" COMPACTED AGGREGATE GRADING BASE COURSE,
MINIMUM 95% RELATIVE COMPACTION, AASHTO T-99,
METHOD C OR D. SEE SPECIFICATIONS.
6" MIN. DEPTH NATIVE SOIL SUBGRADE
COMPACTED TO 95% RELATIVE COMPACTION,
AASHTO T-99, METHOD C OR D. SEE
SPECIFICATIONS.
HARDENED
AGGREGATE SURFACE
G-10
ADD ADDITIONAL 1' TO ACCOMMODATE
POST BARRIERS WHERE LIVING AREA
ABUTS END OF PARKING SPUR
ADD ADDITIONAL 1' TO ACCOMMODATE
POST BARRIERS WHERE LIVING AREA
ABUTS END OF PARKING SPUR
ADD ADDITIONAL 1' TO ACCOMMODATE
POST BARRIERS WHERE LIVING AREA
ABUTS END OF PARKING SPUR
ADD ADDITIONAL 1' TO ACCOMMODATE
POST BARRIERS WHERE LIVING AREA
ABUTS END OF PARKING SPUR
COMPACTED NATIVE SOIL
SHOULDER (TYP.)
REQUIRED CLEAR SPACE:
NATURAL OBJECTS MAY BE INCORPORATED INTO THE
CAMPSITE LIVING SPACE AND TENT PAD, AS LONG AS THE
MINIMUM 4 FT OF CLEAR SPACE IS MAINTAINED AROUND
THE PICNIC TABLE AND FIRE RING.
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
(R05)
PACIFIC SOUTHWEST REGION
GAOA SCENIC
BYWAY -
CAMPGROUNDS
SIERRA NATIONAL
FOREST
BASS LAKE
RANGER DISTRICT
CAMPSITE
DETAILS
10/30/2024
CESAR S.
CESAR S.
ANTONIO C.
G-07 8 28
SIDE VIEW
FRONT VIEW
NOTES:
1. TABLE SHALL BE MANUFACTURED BY PILOT ROCK: A REGISTERED TRADEMARK OF R.J.
THOMAS MFG. CO., INC., P.O. BOX 946, CHEROKEE, IOWA 51012. (712) 225-5115. www.pilotrock.com.
"UNIVERSAL ACCESS PICNIC TABLE W/3"X10" RECYCLED PLASTIC SEAT AND TOP PLANKS WITH
EMBOSSED WOOD GRAIN SURFACE," MODEL#: 'WPTS/CB-8PW31X - DRAWING #57867 WITH
ADDITIONAL SNOW LOAD SUPPORT AND EMBOSSED WOOD GRAIN SURFACE' OR APPROVED
EQUAL BY THE FOREST SERVICE REPRESENTATIVE. INSTALLATION SHALL BE ACCORDING TO
MANUFACTURER'S RECOMMENDATIONS.
95 1/2"
12 3/4" 35" 35"
6"
1 5/8"
9 1/4"
6"
8 3/4"
13 1/8"
25 7/8"
51 3/4"
78"
95 1/2"
24"
18 1/2"
29 5/8"
32 1/8"
28 3/4" 6"
59 1/4"
PICNIC TABLE
G-8
NTS
"BLACK" POWDER COATED FRAMES
(3"X6" RECTANGULAR STEEL FRAMES
CONNECTED BY 2-1/2" SQUARE STEEL
FRAMES). ALL BOLTS FOR FRAME ARE
HOT-DIP GALVANIZED
3"x10"x8' "BROWN" COLORED RECYCLED PLASTIC
PLANKS. THE RECYCLED PLASTIC PLANKS SHALL
HAVE A "WOOD GRAIN EMBOSSED" SURFACE ON THE
TOP SURFACE.
PICNIC TABLE ANCHOR
PICNIC TABLE ANCHOR
G-8
NTS
PICNIC TABLE
FINISHED GRADE
MODEL 68 II DUCKBILL
EARTH ANCHOR OR
APPROVED EQUAL
3/16" PVC COATED
GALVANIZED CABLE
(CABLE DIAMETER
PVC COATED GALVANZED
CABLE SHALL BE LANDMAN
WIRE ROPE PRODUCTS OR
APPROVED EQUALL.
36" MIN.
INSTALL ANCHOR AROUND CENTER VERTICAL FRAME.
INSTALL ANCHOR DIRECTLY DOWN AS SHOWN (NOT
AT AN ANGLE) TO AVOID TRIPPING HAZARD.
ALL EXPOSED BOLTS ON TABLE AND SEAT TOPS ARE
HOT-DIP GALVANIZED.
G-8
INSTALLATION
NOTES:
1. FOOD STORAGE LOCKERS SHALL BE MANUFACTURED BY BEAR SAVER,
1390 S. MILLIKEN AVE., ONTARIO, CA 91761. (909) 605-1697 OR (800)
851-3887. www.bearsaver.com. "ADA COMPLIANT 24 CUBIC FOOT CAPACITY
FOOD STORAGE LOCKER, MODEL#: 'FS24-UP', POWDER COATED TIGER
DRYLAC RAL 8019 IN COLOR, OR APPROVED EQUAL BY THE FOREST
SERVICE REPRESENTATIVE.
BEAR RESISTANT FOOD STORAGE
LOCKER, MODEL#: 'FS24-UP'
10"
DIA.
FOOD LOCKER
G-8
NTS
24"
29"
47"
45"
FIRE RING
G-8
NTS
G-10
GRATE ROTATES 180 DEGREES
TO OUTSIDE FIRE RING
8" DIA. X 24" CONCRETE
FOOTING (MIN)
MODEL#: FSW/SL-30/18/PA or equivalent.
TOP VIEW
NATIVE SOIL
9" OF COARSE AGGREGATE
FILL INSIDE RING TO RAISE
FIRE TO WORKING HEIGHT
AND TO CONFORM TO ADA
GUIDELINES OF 9" MIN.
HEIGHT ABOVE GROUND
FOR FIRE BASE
19 3/8"
47 3/4"
30 3/8" ID
15 1/8"
32 (NOM) OD
16 7/8"
13 3/4"
24"
19 13/16"
23 9/16"
48 11/16" OD
CENTER OF FIRE RING
WITH GRATE ROTATED
OUTSIDE OF FIRE RING
NOTES:
1. RECOMMENDED PROVIDER FOR FIRE RINGS IS PILOT ROCK
www.pilotrock.com, (712) 225-5115. Model FSW/SL-30/18/PA or equivalent approved by CO.
2. Fire ring grate shall support snow loads no less than 560 lbs/sqft., ring side height not less than 11inches, with angle spade anchors and meet
ADA guidelines.
CONSTRUCT
HARDENED
AGGREGATE
SURFACE
8" DIA. X 24" CONCRETE
FOOTING (MIN)
G-10
3"DIA X 68" BLACK IRON PIPE FILLED WITH
CONCRETE. PAINT EXPOSED CONCRETE.
COLOR SHALL BE "DARK CHOCOLATE".
BLACK IRON PIPE SHALL BE PAINTED IN ACCORDANCE
WITH THE SPECIFICATIONS. COLOR SHALL BE "DARK
CHOCOLATE" OR APPROVED EQUAL. APPLY TWO COATS OF
PRIMER AND TWO COATS OF DIRECT TO METAL PAINT TO
ALL METAL AND HARDWARE. PRIMER SHALL BE "PRO
INDUSTRIAL DTM PRIMER".
U-BOLTS GO AROUND POST AND THROUGH BOX
(KNOCK-OUTS ARE ON THE BACK OF EVERY STORAGE
LOCKER FOR U-BOLTS INSERTION) AND PAINTED IN
ACCORDANCE WITH THE SPECIFICATIONS, COLOR SHALL BE
"DARK CHOCOLATE". APPLY TWO COATS OF PRIMER AND
TWO COATS OF DIRECT TO METAL PAINT TO ALL METAL AND
HARDWARE. PRIMER SHALL BE "PRO INDUSTRIAL DTM
PRIMER".
SURFACE COURSE (HARDENED
AGGREGATE)
10" DIA. X 24" DEEP CONCRETE FOOTING
MANUFACTURER SHALL DESIGN
BRACING TO ENSURE BENCH CAN
WITHSTAND EXTREME SNOW LOADS
ANTICIPATED AT PROJECT LOCATION.
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
(R05)
PACIFIC SOUTHWEST REGION
GAOA SCENIC
BYWAY -
CAMPGROUNDS
SIERRA NATIONAL
FOREST
BASS LAKE
RANGER DISTRICT
CAMPSITE
FURNITURE
DETAILS
10/30/2024
CESAR S.
CESAR S.
ANTONIO C.
G-08 9 28
"DO NOT ENTER" SIGN
G-9
NTS
STOP
4"
30"
30"
1'-6"
STOP SIGN (R1-1)
NOTE 3 AND 11
5' MIN
"ONE WAY" SIGN
G-9
NTS
4"
18"
24"
1'-6"
ONE-WAY SIGN (R6-2)
NOTE 3 AND 11
ONE
WAY
4"
30"
30"
4'-0"
1'-6"
NOTE 3 AND 11
EDGE ROAD SURFACE
5' MIN
DO NOT
ENTER
DO NOT ENTER SIGN
5' MIN
G-9
NTS
"STOP" SIGN
CAMPING UNITS SIGN
NTS
CAMPING
UNITS
1-8
19"
19"
4"
3'-0"
4'-11"
6"
6"
8'-11"
1'-6"
NOTE 4
NOTE 3 AND 11
NOTES:
1. THE FINAL CONTENT, ARROW DIRECTION, AND SIGN SIZES TO BE
APPROVED BY THE FOREST SERVICE DURING THE SUBMITTAL
PROCESS.
2. CAMPING UNITS SIGNS SHALL BE 19"X19"X3/4" REFLECTIVE
ALUMINUM SIGN W/ 3" LETTERS, NUMBERS AND ARROWS IN 'WHITE
COLOR' ON 'BROWN' BACKGROUND WITH 3/8" 'WHITE' BORDER,
2'
MIN
ROAD
4'-0"
DIRECTIONAL SIGN
NTS
SEE BELOW FOR
CONTENT INFORMATION
NOTE 1
4"X4" POSTS, SEE NOTES 3 AND 11
4"
6"
1'-4"
6"
20"
4"
20"
7'-0"
4'-0"
11'-0"
5' MIN
40"
NOTES:
1. THE FINAL CONTENT, ARROW DIRECTION, AND SIGN SIZES TO BE
APPROVED BY THE FOREST SERVICE DURING THE SUBMITTAL PROCESS.
2. FINAL CONTENT FOR FLOOD WARNING SIGN TO BE PROVIDED BY SCE.
G-9
G-9
CAMPGROUND
INSTALL CAMPING
UNIT SIGNS BEHIND
ROCK AND POST
BARRIERS
SIGN INSTALLATION
1) CARRIAGE BOLT (3/8")
2) GALV. WASHER
3) SIGN
4) POST (6"X6" OR 4"X4")
5) METAL WASHERS
6) ANTI-VANDALISM NUT
NOTES:
1. ALL SIGN POSTS SHALL HAVE 1" 45° CHAMFER ON TOP END OF POST,
UNLESS NOTED OTHERWISE.
2. ALL CARRIAGE BOLTS SHALL BE 3/8"; ROUND HEAD, INSTALLED PER THE
SIGN INSTALLATION DETAIL.
3. ALL POSTS SHALL BE PRESSURE TREATED 4"X4" UNLESS SPECIFIED,
4. ALL POSTS SHALL BE SECURED BY COMPACTED NATIVE SOIL AROUND THE
BASE OF THE POST.
5. SUGGESTED VENDOR FOR RECYCLED PLASTIC SIGNS IS:
WOOD PRODUCT SIGNS ROUTED RECYCLE PLUS, INC., 4890 COUNTY
ROAD 76, PARLIN, CO 81239. (970) 641-1675. www.woodproductsigns.com
OR APPROVED EQUAL BY THE FOREST SERVICE.
6. ALUMINUM SIGNS SHEETING SHALL BE REFLECTIVE AS FOLLOWS AND HAVE
ANTI-VANDALISM HARDWARE.
6.1. Stop, Do no enter Diamond Grade(DG)
6.2. One Way High Intensity prism (HIP)
6.3. All other signs Engineering Garde(EG)
7. ALL ALUMINUM SIGNS SHALL BE COVERED WITH 3M ANTI-GRAFFITI FILM
OR EQUIVALENT FOR SNOW PROTECTION - COVER THE ENTIRE FACE OF
THE SIGN AND FOLD 2" TO COVER THE BACK OF THE SIGN.
8. THE FINAL LOCATION OF THE SIGNS SHALL BE DETERMINED IN THE FIELD
BY THE FOREST SERVICE IN COORDINATION WITH THE CONTRACTOR.
9. BREAKAWAY HOLES SHALL BE PERPENDICULAR TO THE DIRECTION OF
VEHICLE TRAVEL. TREAT BREAKAWAY HOLES WITH PRESERVATIVE.
10. ALL SIGNS SHALL BE INSTALLED 2' MIN FROM EDGE OF ASPHALT, AND
WHERE BOLLARDS ARE PRESENT, SHALL BE INSTALLED 0.5' BEHIND BACK
OF BOLLARD. CAMPING UNIT SIGNS SHALL BE INSTALLED EVEN WITH
BOLLARDS.
11. TREAT ALL FIELD CUTS AND BOREHOLES WITH COPPER NAPTHENATE (OR
APPROVED EQUAL). SEE SPECIFICATIONS.
SIGN AND POST INSTALLATION NOTES
NTS
G-9
2'
MIN
9-18
NOTE 4
4"
18"
4'-0"
EDGE ROAD SURFACE
2'
MIN
4'-0"
EDGE ROAD SURFACE
2'
MIN
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
(R05)
PACIFIC SOUTHWEST REGION
GAOA SCENIC
BYWAY -
CAMPGROUNDS
SIERRA NATIONAL
FOREST
BASS LAKE
RANGER DISTRICT
SIGN DETAILS 2
10/30/2024
CESAR S.
CESAR S.
ANTONIO C.
G-9 10 28
2% SLOPE PER PLANS
X
X
NOTES:
1. ALL COLORED CONCRETE SURFACES SHALL BE APPROVED BEFORE PLACEMENT.
2. A CONCRETE MIX DESIGN FOR CONCRETE SLABS SHALL BE SUBMITTED BY THE CONTRACTOR 14 DAYS PRIOR TO SCHEDULED
PLACEMENT, TO ALLOW FOR REVIEW AND APPROVAL BY CO.
3. CONCRETE SHALL HAVE A STAMPED FINISH. THE CONTRACTOR SHALL SUBMIT VARIOUS TEXTURES TO FOREST SERVICE FOR
APPROVAL OF DESIRED STAMPED TEXTURE FINISH.
4. CONCRETE SEALANT SHALL BE INCRETE SYSTEMS CLEAR SEAL 100 OR APPROVED EQUAL.
5. SEE SPECIFICATIONS FOR SAMPLING AND SUBMITTAL REQUIREMENTS.
6. INTEGRATED COLORED CONCRETE SHALL BE "SCOFIELD INTEGRAL COLOR SG 084 HAY FIELDS" OR APPROVED EQUAL BY THE
FOREST SERVICE.
EXISTING SLOPE
C L E
A R
I N
G
H E
I G
H
STAMPED COLORED CONCRETE SECTION
G-10
NTS
4" COMPACTED AGGREGATE, BASE COURSE,
GRADING B, MINIMUM 95% RELATIVE
COMPACTION, AASHTO T-99, METHOD C OR D.
SEE SPECIFICATIONS.
EXISTING SLOPE
AS SHOWN ON PLANS
X
X
2% MAX. SLOPE
NOTES:
1. ALL HARDENED AGGREGATE SURFACES SHALL BE CONSTRUCTED AS SHOWN ON
THE PLANS AND AS APPROVED IN THE FIELD BY THE FOREST SERVICE
REPRESENTATIVE.
2. SEE SPECIFICATIONS FOR REQUIREMENTS FOR HARDENED AGGREGATE SURFACES.
3. CROSS SLOPE SHALL NOT EXCEED 2%.
HARDENED AGGREGATE SURFACE SECTION
G-10
NTS
12in WIDE COMPACTED
NATIVE SOIL SHOULDER
(TYP.)
MAXIMUM FINISHED SUBGRADE WIDTHS:
3' TRAILS - 5'
5' TRAILS - 8'
OUTDOOR RECREATION ACCESS ROUTE (ORAR)
G-10
NTS
EXISTING GROUND
HARDENED AGGREGATE SURFACE
OR COLORED CONCRETE SURFACE
3'-5'
2'±
CLEARING LIMITS
CLEARING HEIGHT 10'
FULL BENCH >10% SIDE SLOPE
BALANCED BENCH 5% TO 10% SIDE SLOPE
NOTES:
1. REMOVE ALL VEGETATION IN THE TRAILWAY.
2. FOR SIDE SLOPES OF 5% TO 10%, BALANCE CUT AND FILL, SEE BALANCED BENCH.
3. FOR SIDE SLOPES GREATER THAN 10%, TRAIL TO BE ALL CUT, SEE FULL BENCH.
4. FOR SIDE SLOPES LESS THAN 5%, TRAIL TO MATCH GRADE OR BE ALL FILL TO HELP DRAINAGE, SEE NO
BENCH.
5. LONGITUDINAL SLOPE (RUNNING GRADE) SHOULD BE LESS THAN HALF OF THE SIDE SLOPE OF THE
HILLSIDE.
6. DO NOT REMOVE TREES OVER 6" IF THEY ARE OVER 3' FROM THE CENTERLINE OF TRAIL.
7. REMOVE TREES 6" OR LESS IN DIAMETER IF THEY ARE WITHIN 3' OF CENTERLINE OF TRAIL.
8. SAW BRANCHES FLUSH WITH TRUNK FOR ANY TREE BRANCHES EXTENDING INTO THE CLEARING LIMITS
OF THE TRAIL.
9. BRUSH EXTENDING INTO CLEARING LIMITS THAT IS OVER 12 INCHES IN HEIGHT AND 1/2 INCH IN
DIAMETER SHALL BE CUT FLUSH WITH THE MAIN STEM AT A BRANCH OR AT GROUND LEVEL IF A FORK
MAIN STEM IS NONEXISTENT.
10. CUT ALL LOGS IN TRAILWAY 4 FEET UPHILL AND DOWNHILL OF CENTERLINE OF TRAIL.
TRAIL BED
TRAIL BED
EXISTING GRADE
EXISTING GRADE
NO BENCH <5% SIDE SLOPE
TRAIL BED
EXISTING GRADE
TRAIL FG MATCH EG
TRAIL FG MATCH EG
TRAIL FG MATCH EG
1' WIDE COMPACTED NATIVE
SOIL SHOULDER
(TYP.)
2'±
CUT BRANCHES FLUSH
WITH TRUNK TO AVOID
STUBS (TYP.)
CUT BRANCHES FLUSH
WITH TRUNK TO AVOID
STUBS (TYP.)
G-6
6" DEPTH COLORED CONCRETE WITH
#4 REBAR AT 18" O.C. BOTH WAYS
TYPICAL 5 FEET UNLESS
SHOWN ON PLANS
6" MIN. DEPTH NATIVE SOIL SUBGRADE
COMPACTED TO 95% RELATIVE COMPACTION,
AASHTO T-99, METHOD C OR D. SEE
SPECIFICATIONS.
4" COMPACTED GRADING BASE COURSE, MINIMUM 95%
RELATIVE COMPACTION, AASHTO T-99, METHOD C OR D.
SEE SPECIFICATIONS.
6" MIN. DEPTH NATIVE SOIL SUBGRADE
COMPACTED TO 95% RELATIVE COMPACTION,
AASHTO T-99, METHOD C OR D. SEE
SPECIFICATIONS.
G-6
1' WIDE MIN.
COMPACTED NATIVE
SOIL SHOULDER
1' WIDE MIN.
COMPACTED NATIVE
SOIL SHOULDER
1' WIDE MIN.
COMPACTED NATIVE
SOIL SHOULDER
EXISTING SLOPE
1' WIDE COMPACTED NATIVE SOIL SHOULDER
EXISTING GROUND
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
(R05)
PACIFIC SOUTHWEST REGION
GAOA SCENIC
BYWAY -
CAMPGROUNDS
SIERRA NATIONAL
FOREST
BASS LAKE
RANGER DISTRICT
OUTDOOR
RECREATION
ACCESS ROUTES
(ORAR) DETAILS
10/30/2024
CESAR S.
CESAR S.
ANTONIO C.
G-10 11 28
TRASH BIN
ENCLOSURE
WALL
NOTES:
1. ALL POSTS AND SLATS SHALL BE STAINED IN ACCORDANCE WITH THE
SPECIFICATIONS. COLOR SHALL BE "DARK CHOCOLATE" OR APPROVED
EQUAL BY FOREST SERVICE REPRESENTATIVE.
2. ALL EXPOSED BOLTS AND METAL FRAMES SHALL BE PAINTED IN
ACCORDANCE WITH THE SPECIFICATIONS. COLOR SHALL BE SAME AS POSTS.
APPLY TWO COATS OF PRIMER AND TWO COATS OF DIRECT TO METAL PAINT
TO ALL METAL AND HARDWARE. PRIMER SHALL BE "PRO INDUSTRIAL DTM
PRIMER".
3. FOR TRASH ENCLOSURES LOCATED ON UPHILL SIDE OF ROAD, SLOPE PAD
AND APRON TOWARDS ROAD TO ALLOW FOR PROPER DRAINAGE.
4. SUGGESTED MANUFACTURE FOR DUMPSTER IS:
HANA CARRASCO
McLAUGHLIN WASTE EQUIPMENT, INC.
11900 E. Locke Rd
LOCKEFORD, CA 95237
Ph. 209-663-0858 hana@mwecans.com
Web Site: www.wastequip.com
MODEL#: 2 YARD STANDARD REAR LOAD DUMPSTER WITH BEAR
RESISTANT AND SPECIAL APARTMENT LIDS AND SPECIAL LOCKING
BAR AT 2", SPECIAL BRACE ON SMALLER LID ALL THE WAY TO THE
FRONT TO BE FLUSH UNDER LOCKING BAR. CHAIN NEEDS TO BE ON
DRIVER SIDE AND LIDS MUST BE IN MIDDLE OF EACH BAR IN FOREST
SERVICE BROWN COLOR PER SIERRA NATIONAL FOREST
SPECIFICATIONS.
TRASH ENCLOSURE
G-11
NTS
TYPICAL POST BASE INSTALLATION
NTS
RAILROAD TIE WHEEL STOP
NTS
ANCHOR
8"
8"
24" STAKES. (3 PER WHEEL STOP)
NOTES:
1. PRESSURE TREATED WHEEL STOPS SHALL BE DOUGLAS FIR GREEN ROUGH SAWN NO. 1 GRADE, HEAVY DUTY (UC4B) OR APPROVED EQUAL BY THE FOREST
SERVICE. SEE SPECIFICATIONS
2. WHERE APPLICABLE MAKE DIMENSIONAL CUTS AND BOREHOLES BEFORE PRESSURE TREATMENT.
3. TREAT ALL FIELD CUTS AND BOREHOLES WITH COPPER NAPTHENATE (OR APPROVED equal).
4. THE WHEEL STOPS SHALL BE ANCHORED WITH THREE (3) 3/4" X 24".
5. DRILL 3/4" DIA. HOLE THROUGH THE ASPHALT OR CONCRETE SLAB AT EACH HOLE LOCATION TO AVOID FRACTURING THE ASPHALT WHEN DRIVING IN THE
STAKE. HEAD OF THE STAKE SHALL BE FLUSHED WITH THE TOP OF THE CAR STOP. THE ANCHOR HOLES IN THE RAILROAD TIES SHALL BE PREDRILLED.
G-11
A
G
G
R
E
G
A
B
R
O
N
S
L
O
F
C
O
N
C
R
E
A
B
O
C
4"x 1"x 4'-6" CONSTRUCTION GRADE DF
5'-0"
1'-1"
O
C
O
C
BASE OR EQUAL
USE SIMPSON CB66 POST
A
3'-10"
1" 45° CHAMFERED EDGES ON POSTS
CONCRETE SLAB
R=2'
E
D
G
V
E
M
E
N
T
V
A
R
I
E
S
P
INSTALL 8' WHEEL STOP (1 PER PAD)
2"x 6" BUMPER RAIL
CONSTRUCTION GRADE DF
@ 3'-10"DIA. ABOVE SLAB
2" x 6" CONSTRUCTION GRADE D.F.
ATTACHED TO POST W/JOIST HANGER
6"x 6"x 5' PRESSURE
TREATED DF POST
JOIST HANGER PRIMED & PAINTED
G-10
6"
STANDARD SIZED 8"X8"
ROUGH CUT PRESSURE
TREATED TIMBER
RAILROAD TIE
CONCRETE SLAB
G-11
A
SIMPSON STRONG-TIE
CB66
3" MINIMUM
SIDECOVER
6"X6" TREATED POST
CONCRETE SLAB
SIMPSON CB66
POST BASE OR
APPROVED
EQUAL
DRILLED HOLES TO
EXACTLY MATCH BOLT
DIAMETER TO PREVENT
LOOSE CONNECTIONS
BRACKET INNER DIMENSIONS
SHALL EXACTLY MATCH OUTER
DIMENSIONS OF POST. NO
CUTTING OR SHAVING OF POST
ALLOWED
THICKENED CONCRETE SLAB
UNDER BRACKET TO ENSURE
3" MINIMUM CLEARANCE OF
CONCRETE SURROUNDING
BRACKET
7/8" DIA. THRU HOLES TO BE SHOP DRILLED.
HOLES SHALL BE 16" FROM EACH END AND
AT THE CENTER OF THE RAILROAD TIE.
" GROUND SPACER, TYP
(PART NO. 800-032)
24" STAKE, TYP
(MODEL #ANC12-3)
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
(R05)
PACIFIC SOUTHWEST REGION
GAOA SCENIC
BYWAY -
CAMPGROUNDS
SIERRA NATIONAL
FOREST
BASS LAKE
RANGER DISTRICT
TRASH
ENCLOSURE AND
DUMPSTER
DETAILS
10/30/2024
CESAR S.
CESAR S.
ANTONIO C.
G-11 12 28
ROCK AND POST BARRIER
G-12
NTS
C C
BARRIER POSTS
MAXIMUM
FINISH
GRADE
O.C.MAX.
MAX.
MINIMUM
X
1 MIN.
TYPICAL ROCK GROUPING DETAIL
Good set
Poor set
ROCK NOTES:
1. ROCKS SHOULD VARY IN DISTANCE FROM SHOULDER OF ROAD & BE RANDOMLY SPACED FOR MORE
NATURAL APPEARANCE.
2. BURY ROCKS WITH WEATHERED PORTION ABOVE GROUND & AT LEAST 1/3 OF ROCK BELOW GRADE
TO REFLECT NATURAL FORMATIONS & TO CREATE VISUAL STABILITY. DO NOT SET ROCK ON GRADE.
PLACE ROCKS WITH LARGEST DIMENSION PARALLEL TO ROADWAY.
3. GROUPINGS OF VARIED SIZED ROCKS & RELATING BARRIERS TO EXISTING OUTCROPS IS DESIRABLE.
4. PLACE ROCK BARRIERS 2' MIN. FROM EDGE OF ROAD AND PARKING SPURS, EXCEPT WHERE SHOWN
OTHERWISE ON THE PLANS OR AS DIRECTED BY THE FOREST SERVICE REPRESENTATIVE.
5. ROCKS SHALL BE INSTALLED AT THE LOCATIONS SHOWN ON THE PLANS UNLESS DIRECTED
OTHERWISE BY THE FOREST SERVICE.
6. ROCKS MAY NOT BE SCAVENGED FROM THE PROJECT SITE TO BE USED AS BARRIERS. EXISTING
ROCK BARRIERS OR ROCK ENCOUNTERED DURING EXCAVATION MAY BE USED AS BARRIERS.
7. WHEN EXISTING ROCK BARRIERS OR ROCK BOULDERS ARE NOT AVAILABLE ONSITE, CONTRACTOR
SHALL PURCHASE ROCK BOULDERS. BOULDERS SHALL BE PURCHASED FROM AND DELIVERED BY:
BEDROCK BOULDERS, 35045 MANON AVE., MADERA, CA 93636. 599-916-7623. CONTACT PERSON: PHIL
BILSKEY (OR APPROVED EQUAL BY THE FOREST SERVICE REPRESENTATIVE).
PLAN
C C
BARRIER POSTS
C
SECTION
MAX.
Good set
M I N
3'-5"
4'-0" 4'-0"
5'-0" O.C.
5'-0" O.C.
5'-0" O.C.
4'-0"5'-0" 5'-0"4'-0"
A
A
MIN. SIZE ROCK: 8 CU FT / 1400 LB
AVG. SIZE ROCK: 9 CU FT / 1600 LB
MAX. SIZE ROCK: 18 CU FT / 3200 LB
DESIRED RATIO:
3 AVG.
1 MAX.
M I N
RELATE ROCK WITH OTHER
LANDSCAPE FEATURES TO
BETTER BLEND.
SQUARE POSTS. UTILIZE POSTS IN
OPEN FLAT AREAS, POSTS SHALL BE
LOCATED AS SHOWN ON THE PLANS.
SEE POST NOTES
EXISTING TREES
AND SHRUBS.
EXISTING
ROCKS
TYPICAL ROCK
GROUPING:
1-5 ROCKS.
UTILIZE NATURAL BARRIERS SUCH AS EXISTING TREES,
SHRUBS, ROCK OUTCROPPINGS, STEEP SLOPES AND CREEK
CROSSINGS WHERE POSSIBLE AND PRACTICAL. DESIGN A
4'-0" GAP BETWEEN VEGETATION EDGE AND BARRIERS.
ALL POSTS SHALL EXTEND
18" ABOVE FINISH GRADE.
8"x8"x42" LONG (MIN) SQUARE POSTS. BARRIER
POSTS SHALL BE BURIED A MIN. OF 24" BELOW
GRADE. POSTS SHALL HAVE 1" 45° CHAMFER ON
TOP END. SEE POST NOTES.
MAX.
4'-0"
EP
EP
2' OFFSET FROM AGGREGATE BASE
ROAD
POST NOTES:
1. BARRIER POSTS SHALL BE MANUFACTURED BY: PERMAPOST PRODUCTS
CO., 4205 SE WITCH HAZEL RD, HILLSBORO, OREGON 97123. ATTENTION
JAYNE BOND OR BRUCE LIPPS. 503-619-0212 OR
SALES.PERMAPOST@GMAIL.COM.
2. TREATMENT ON POSTS SHALL BE K-520 COPPER NAPHTHENATE TREATED
MATERIAL, TYPE A SOLVENT, MAXIMUM DARK COLOR, COASTAL DOUGLAS
FIR GREEN ROUGH SAWN NO. 1 GRADE, HEAVY DUTY (UC4B), INDEPENDENT
INSPECTION AND BMP OR APPROVED EQUAL BY THE FOREST SERVICE.
3. TREAT TIMBERS WITH PRESERVATIVES CONFORMING TO THE
SPECIFICATIONS.
4. WHERE APPLICABLE MAKE DIMENSIONAL CUTS AND BORE HOLES BEFORE
PRESSURE TREATMENT.
5. TREAT ALL FIELD CUTS AND BOREHOLES WITH COPPER NAPTHENATE (OR
APPROVED EQUAL).
6. PLACE BARRIER POSTS 2' MIN. FROM EDGE OF ROAD AND PARKING SPURS,
EXCEPT WHERE SHOWN OTHERWISE ON THE PLANS OR AS DIRECTED BY
THE FOREST SERVICE REPRESENTATIVE.
8. BARRIER POST GROUPING: MAXIMUM 5 POSTS IN A ROW, MINIMUM 2 POSTS.
9. POSTS SHALL BE INSTALLED AT THE LOCATIONS SHOWN ON THE PLANS
UNLESS DIRECTED OTHERWISE BY THE FOREST SERVICE.
G-12
NTS
38"
8"
6"
20"
EXISTING
GROUND
48"
COMPACTED
NATIVE SOIL
8"X8"X4' PRESSURE TREATED DOUGLAS FIR
POSTS.
3/4" DIA X 12"
GALVANIZED CARRIAGE
BOLT WITH NUT
(TYP.)
4"
4"X8" ROUGH SAWN DOUGLAS FIR
RAIL, PRESSURE TREATED.
7'
10'
HORIZONTAL BARRIER
2'
2"
10"
8"
EP
POSTS SHALL BE MANUFACTURED BY:
PERMAPOST PRODUCTS CO., 4205 SE WITCH HAZEL
RD, HILLSBORO, OREGON 97123.
ATTENTION JAYNE BOND OR BRUCE LIPPS.
503-619-0212 OR SALES.PERMAPOST@GMAIL.COM.
TREATMENT ON POSTS SHALL BE K-520 COPPER
NAPHTHENATE TREATED MATERIAL, TYPE A
SOLVENT, MAXIMUM DARK CHOCOLATE COLOR,
COASTAL DOUGLAS FIR GREEN ROUGH SAWN NO. 1
GRADE, HEAVY DUTY (UC4B), INDEPENDENT
INSPECTION AND BMP OR APPROVED EQUAL BY THE
FOREST SERVICE.
2' DIAMETER
3'-4"
3'-6"'
FEE TUBE
D-12
NTS
SECTION ELEVATION
8" (TYP.)
2" CLR,
TYP
NOTES:
1. FEE TUBE SHALL MEET OR EXCEED MANUFACTURED BY ROCK ART SIGNS AND MARKERS,
480-854-3400
2. POST SHALL BE MODEL #03-561-BASE. DEPOSIT BOX SHALL BE MODEL #03-564.
3. THE FINAL LOCATION OF THE FEE TUBE TO BE DETERMINED IN THE FIELD BY THE SCE
EDISON REPRESENTATIVE IN COORDINATION WITH THE CONTRACTOR
2"
CLR,
TYP
PLAN VIEW
ROCK ART REMOVABLE FEE
DEPOSIT BOX ASSEMBLY,
MODEL #03-564
ROCK ART "HARD ROCK RANGER"
8"X8"X80" SQUARE TUBE, MODEL
#03-561-BASE (STEEL CONSTRUCTION)
NO. 4 REBAR HOOPS
UNDISTURBED SOIL
COLORED MINOR CONCRETE
FOOTING
NO. 4 REBAR CAGE
(12" O.C. MAX. BOTH WAYS)
ROCK ART "HARD ROCK RANGER"
8"X8"X80" SQUARE TUBE, MODEL
#03-561-BASE (STEEL CONSTRUCTION)
NO. 4 REBAR CAGE
(12" O.C. MAX. BOTH WAYS)
24" DIA. X 40" DEEP
COLORED MINOR
CONCRETE FOOTING
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
(R05)
PACIFIC SOUTHWEST REGION
GAOA SCENIC
BYWAY -
CAMPGROUNDS
SIERRA NATIONAL
FOREST
BASS LAKE
RANGER DISTRICT
BARRIERS AND
FEE TUBE
DETAILS
10/30/2024
CESAR S.
CESAR S.
ANTONIO C.
G-12 13 28
12" MIN
(TYP)
OD + 2' MINOD + 2' MIN
12" MIN
(TYP)
6" 6"
IN PAVEMENT
12"
12"
1'
PROFILE
ROCK DISSIPATER
G-13
NTS
ROCK LINED DITCH
G-13
NTS
18" CULVERT
G-13
NTS
ISOMETRIC
TYPICAL CULVERT TRENCH
G-13
NTS
OUTLET
G-13
NTS
KEY IN RIP RAP
ROADWAY
NOTES:
1. NEW AND EXISTING CULVERTS SHALL HAVE RIPRAP
ON BOTH THE INLET AND OUTLET AS SHOWN ABOVE.
2. EXISTING CULVERTS SHALL BE FLUSHED AND
CLEANED TO RESTORE TO ORIGINAL CONDITIONS
USING EQUIPMENT SIMILAR TO VACTOR TRUCK.
3. GRADE AND PLACE RIP RAP AT 1:1 WHEN NOT
GRADING TO ROAD.
3' TYP.
1' TYP.
F
L
NOTES:
1. THE TYPICAL DITCH SHALL BE 1 FT DEEP.
2. WHEN DITCH IS DEEPER THAN 1' STEEPEN SLOPES TO 1:1
MAX OR AS DIRECTED BY FOREST SERVICE
REPRESENTATIVE.
3. FIELD FIT FLOWLINE TO DAYLIGHT AND DIRECT RUNOFF
AWAY FROM SPURS, FAUCETS, LIVING AREAS, AND TOILET
BUILDINGS.
4. FIELD FIT FLOWLINE ALONG ROADWAY AS DIRECTED BY FS
REPRESENTATIVE.
5. SLOPE SWALE TO AVOID PONDING.
8 FT
2 FT
1.5 FT
10 FT
4 FT
10 " Corrugated
Metal Pipe
EXISTING GRADE
PLACE TRACKOUT ROCK 4"X6" IN
CHANNEL, MIN. OF 8" THICKNESS
NATIVE BACKFILL, SEE
SPECIFICATIONS FOR COMPACTION
REQUIREMENTS
FINISH GRADE. EXISTING GROUND
NATIVE BACKFILL, SEE
SPECIFICATIONS FOR
COMPACTION REQUIREMENTS
FLOW LINE OF DITCH
EDGE OF ROCK LINED DITCH
PLACE TRACKOUT ROCK 4"X6" IN
CHANNEL, MIN. OF 8" THICK
FLOW LINE OF DITCH
EDGE OF ROCK LINED DITCH
LENGTH PER PLAN
ROCK LINED DITCH LEADING
TO ROCK DISSIPATER
CULVERT OUTLET/INLET: PLACE CLASS II
RIPRAP TO TOP OF PIPE. COVER ENTIRE
EXPOSED AREA OF PIPE.
ROAD SHOULDER
PROFILE GRADE
CULVERT INLET/OUTLET
PLACE RIPRAP TO TOP
OF PIPE. COVER ENTIRE
EXPOSED AREA OF PIPE.
12" MIN
5'
6'
F L
O W
10' MIN
CLASS II RIP RAP
ROAD EDGE
ROAD EDGE
1'
2'
FLOW LINE
1.5'
2'
2%
1'
PLACE 2 CY OF RIP RAP
AROUND CULVERT
OUTLET TO TRANSITION
TO ROCK LINED CHANNEL
4'
1'
MIN. SEE PLANS FOR RADIUS/DIMENSIONS
SEE CULVERT DETAIL WHEN CURB
OUTLETS TO CULVERT
CAMPGROUND
ROAD
CULVERT INLET:
GRADE AND PLACE RIP RAP
TO TIE INTO CURB OUTLET
G-9
2'
OUT OF PAVEMENT
G-9
EXISTING GRADE
CUT PIPE END AT 45°
G-9
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
(R05)
PACIFIC SOUTHWEST REGION
GAOA SCENIC
BYWAY -
CAMPGROUNDS
SIERRA NATIONAL
FOREST
BASS LAKE
RANGER DISTRICT
DRAINAGE
DETAILS
10/30/2024
CESAR S.
CESAR S.
ANTONIO C.
G-13 14 28
S
Y
PROTECT EXISTING CREEK
INSTALL DOUBLE VAULT TOILET BUILDING
(TOTAL 1 EA)
G-24
NOTES:
1. THE FINAL LOCATION OF THE TOILET BUILDING
AND ROCKLINED DITCH SHALL BE DETERMINED IN
THE FIELD BY THE FOREST SERVICE IN
COORDINATION WITH THE CONTRACTOR.
2. THE STAMPED CONCRETE ORAR. CONSTRUCT A
2% SLOPE IN ANY DIRECTION ON THE 5FT LANDING
OUTSIDE OF THE TOILET BUILDING AND UP TO AN
8.33% RUNNING SLOPE ON THE ORAR LEADING TO
THE LANDING.
3. THE 1-PANEL BULLETIN BOARD. CONSTRUCT A 2%
SLOPE IN ANY DIRECTION ON THE 5FT LANDING IN
FRONT OF THE BULLETIN BOARD.
4. SEE THE TECHNICAL SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
STAMPED CONCRETE ORAR
1-PANEL BULLETIN BOARD
INSTALL ROCKLINED DITCH UNDER ROOF LINE OF TOILET
BUILDING AND SLOPE TO DRAIN WITH NATURAL
TOPOGRAPHY AWAY FROM SITE AMENITIES
I
N
INSTALL ROCK DISSIPATER (TYP.)
G-13
G-05
G-10
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
(R05)
PACIFIC SOUTHWEST REGION
GAOA SCENIC
BYWAY -
CAMPGROUNDS
SIERRA NATIONAL
FOREST
BASS LAKE
RANGER DISTRICT
PLACER
CAMPGROUND
SITE PLAN
10/30/2024
CESAR S.
CESAR S.
ANTONIO C.
G-14 15 28
M
M
O
O
S
PROTECT EXISTING CREEK
INSTALL ROCKLINED DITCH UNDER ROOF LINE OF TOILET
BUILDING AND SLOPE TO DRAIN WITH NATURAL
TOPOGRAPHY AWAY FROM SITE AMENITIES
INSTALL…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .