BOM.xlsx

XLSX spreadsheet 27 KB Posted

Attached to
Radio Shelters Federal contract opportunity
Solicitation number
12760419Q0028
Issued by
Department of Agriculture Forest Service Washington Office Acquisitions

About this file

Bill of Materials

View the file

Other files for this federal contract opportunity

Other files attached to Radio Shelters, newest first.
File Type Posted
Questions.docx DOCX document
R6_Drake_Peak_NEPA_Memo_WR20193029.pdf PDF
Shelter_PWS_April_8_2019.docx DOCX document
GPATLMRFY19LifeCycle.docx DOCX document
R6_Drake_Peak_Shelter_Request_WR20193029.pdf PDF
R9_Ino_Shelter_Request_WR20192953.pdf PDF
R9_Ino_NEPA_LTF_WR20192953.docm DOCM document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

R6 Drake Peak 8x10 Bill of Materials

Shipping Information: Use one sheet per shipping location.
Unit Name to Ship to:R6 Lakeview RD, Fremont-Winema NF
Point of Contact (Local SAT):Danny Antle
Phone (Local SAT):
Street Address:1000 South 9th St
City, State:Lakeview, OR
Zip:97630
Additional Information needed for request.
Project Point of Contact (name and phone):Danny Antle
Additional Technical Contact (name and phone), if applicable:Dennis Brigante
WR # or Incident Number:20193029 001
Override/Job Code:2505/CMFC6F19
Real Property Job CodeR0230119
IAS PMORobin Rowe
UIA110706022301
BOC3220
AAP #:RPSH
POW Line Item # and Project DescriptionWR#20193029
Contract Number and Vendor, if applicable:
Vendor address, point of contact name and phone number, if applicable:
COR, if applicable:Shaun Schnepel
Comments:Road installation by Vendor: Drake Peak communications site Latitude N46 18' 02.12", Longitude W120 09' 27.80", Elevation 8232 ft. Door location: South, Antenna Entry ports: North
LINE
ITEMDESCRIPTIONManufacturers Part Number and/or Critical SpecificationsUnit of IssueQTYUNIT
PRICETOTAL

PRICE

1SHELTER DESCRIPTIONBrand Name, or equivalent ok
2Prefabricated Lightweight Concrete Building 8' wide x 10' long x 8' high exterior dimensionsEA1$ - 0
3Minimum wind load rating of 120 MPH required
4SPECIAL FEATURES:
5Exterior walls: "Faux wood" lap siding exterior finish
6ROOF AND FLOOR
7Roof slant needs to face south (7" on door side) due to solar.
8Roof coating: Uniflex
9Flooring: Standard tile
10Lifting lugs must be removable
11INTERIOR WALLS AND CEILING:
12FRP (Fiber-Reinforced Plastic) covered plywood
13DOOR: Direction East
14Canopy over door
153070 Door, 18 Gauge GalvanizedEA1
163070 Frame, 16 Gauge GalvanizedEA1
17Closer: HD Dorma Grade-1, Aluminum, spring door saver, dead stop, thumb openEA1
18Lock: 626-Entry w/deadbolt functionEA1
19Cylinder Housing, Combined Core, Control Keyway, KeysEA1
20Latch Protector (SS)EA1
21Door PullEA2
22Magnetic Weather StrippingEA1
23Drip Cap: 76" x 2-1/2"EA1
24SS Hinges: Ball BearingEA3
25Threshold: Bumper 36"EA1
26Threshold: Saddle 36"EA1
27CABLE TRAY:
28Estimated 12 linear feet of 12" wide steel cable trays, Running East West, and North to Entry Port.
29CABLE ENTRY:
308 port cable entry 4"
31ELECTRICAL:
32DC
33Surge Arrester 12vdc 30A SPDEA1
34GROUNDING:
35Halo ground with stand off brackets, #2 awg stranded approximately 6” below ceiling, 2 awg connected and run to master ground bar, and equipment rack buss bars.EA1
36One (1) 1/4" x 4" x 20" isolated copper ground plate. Master ground buss bar.EA1
37One (1) 1/4" x 4" x 20" Exterior ground buss bar.EA1
38Equipment rack ground bars connected to master ground bar with 2 AWG green cable.EA4
39Provisions for the connection of a grounding electrode conductor at the shelter service equipmentEA1
40INTERIOR LIGHTS:
4112vdc LED bulbEA4
42EQUIPMENT RACKS
432 post, floor mounted 19" Equipment rackEA4
44VENTILATION
45Passive fixed louverEA1
46OTHER:
47Service Manual detailing location of key shelter components
48Shelter drawings
49Solar Anchor Points on roof (2 runs of Unistrut)EA1$ - 0
50Minumum 10 year structural warranty required.
51Transportation to R6EA1$ - 0
52Faux wood lap exteriror siding, primerEA1$ - 0
53InstallationEA1$ - 0
54
55Delivery Address: 1000 South 9th St, Lakeview OR 97630
56From HWY 395 turn west onto South 9th St. Go west approximately three and a half blocks and turn right into the fenced compound. As you go through the gate go straight ahead to the blue building. Contact the radio tech, Dan Antle, at 541-942 6218 or 541-219-2964 to ensure someone is there to meet you.$ - 0
57GRAND TOTAL$ - 0

R9 Ino 8x10 Bill of Materials

Shipping Information: Use one sheet per shipping location.
Unit Name to Ship to:R9 Washburn RD, Chequamegon-Nicolet NF
Point of Contact (Local SAT):Mitch Wilson
Phone (Local SAT):
Street Address:113 Bayfield St East
City, State:Washburn WI
Zip:54891
Additional Information needed for request.
Project Point of Contact (name and phone):Kevin Throop
Additional Technical Contact (name and phone), if applicable:
WR # or Incident Number:20192953
Override/Job Code:2505/CMFC6F19
Real Property Job CodeR4113919
IAS PMOKristine Roberts
UIA1107091341139
BOC3220
AAP #:RPSH
POW Line Item # and Project Description
Contract Number and Vendor, if applicable:
Vendor address, point of contact name and phone number, if applicable:
COR, if applicable:Shaun Schnepel
Comments:Road installation by Vendor: Ino communications site Latitude N46 31' 28.08", Longitude W91 16' 19.23", Elevation 1244 ft. Door location: South, Antenna Entry ports: East
LINE
ITEMDESCRIPTIONManufacturers Part Number and/or Critical SpecificationsUnit of IssueQTYUNIT
PRICETOTAL

PRICE

1SHELTER DESCRIPTIONBrand Name, or equivalent ok
2Prefabricated Fiberglass reienforced Concrete Building with steel frame 8' wide x 10' long x 8' highEA1$ - 0
3Minimum wind loading of 150 MPH required.
4ROOF AND FLOOR
5Roof coating: Uniflex
6Flooring: Standard tile
7Lifting lugs must be removable
8INTERIOR WALLS AND CEILING:
9Minimum 7" think walls with steel tube frame
10FRP (Fiber-Reinforced Plastic) covered plywood
11DOOR: Direction East
12Canopy over door
133070 Door, 18 Gauge GalvanizedEA1
143070 Frame, 16 Gauge GalvanizedEA1
15Closer: HD Dorma Grade-1, Aluminum, spring door saver, dead stop, thumb openEA1
16Lock: 626-Entry w/deadbolt functionEA1
17Cylinder Housing, Combined Core, Control Keyway, KeysEA1
18Latch Protector (SS)EA1
19Door PullEA2
20Magnetic Weather StrippingEA1
21Drip Cap: 76" x 2-1/2"EA1
22SS Hinges: Ball BearingEA3
23Threshold: Bumper 36"EA1
24Threshold: Saddle 36"EA1
25CABLE TRAY:
26Estimated 12 linear feet of 12" wide steel cable trays, Running East West, and North to Entry Port.
27CABLE ENTRY:
284 port cable entry 4"1
29ELECTRICAL:
30120V/240V, 200A, single phase
3130 space breaker panel with snap in breakers: NEMA 1 surface mount enclosureEA1
32Type 1 Single phase hardware surge suppressor 120/240 1PEA1
33RECEPTACLES:
3420 Amp Specification grade Quad receptacles, One above each equipment rack on ceiling, one on North and west wall.EA5
3520 Amp Specifications Exterior grade Duplex GFI ReceptacleEA1
36GROUNDING:
37Halo ground with stand off brackets, #2 awg stranded approximately 6” below ceiling, 2 awg connected and run to master ground bar, and equipment rack buss bars.EA1
38One (1) 1/4" x 4" x 20" isolated copper ground plate. Master ground buss bar.EA1
39One (1) 1/4" x 4" x 20" Exterior ground buss bar.EA1
40Equipment rack ground bars connected to master ground bar with 2 AWG green cable.EA3
41Provisions for the connection of a grounding electrode conductor at the shelter service equipmentEA1
42INTERIOR LIGHTS:
43LED lightingEA2
44EQUIPMENT RACKS
452 post, floor mounted 19" Equipment rackEA3
46VENTILATION
47HVACEA1
48OTHER:
49Service Manual detailing location of key shelter components
50Shelter drawing approval required
51Final Shelter drawings required
52Minumum 10 year structural warranty required.
53
54Transportation to R9EA1$ - 0
53InstallationEA1$ - 0
55Delivery Address: Forest Rd 234B, Mason, WI 54856
56$ - 0
57GRAND TOTAL$ - 0

File details come from the government source that posted it.