ture_Renovations_Construction_Requisition_Dwgs.pdf
PDF 9 MB Posted
- Attached to
- Facility Infrastructure Inprovements Federal contract opportunity
- Solicitation number
- 1263PX19Q0065
About this file
Drawings for the renovation part of the project.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| A501_Ammended_07292019.pdf | ||
| dwg-07292019.zip | ZIP file | |
| E201_Ammended_07302019.pdf | ||
| M101_Ammended_07292019.pdf | ||
| Amendment-003-0065.pdf | ||
| GR_Sign_in.pdf | ||
| SF-30_GR-001.pdf | ||
| SF-30-001.pdf | ||
| d_Siding_Upgrade_Construction_Requisition_Dwgs.pdf | ||
| ure_Renovations_Construction_Requisition_Specs.pdf | ||
| RFP-Grand_Rapids_Infrastructure_Improvements.doc | DOC document | |
| Siding_Upgrade_Construction_Requisition_Specs.pdf | ||
| ure_Renovations_Construction_Requisition_Specs.pdf | ||
| d_Siding_Upgrade_Construction_Requisition_Dwgs.pdf | ||
| Siding_Upgrade_Construction_Requisition_Specs.pdf | ||
| ure_Renovations_Construction_Requisition_Specs.pdf | ||
| ure_Renovations_Construction_Requisition_Specs.pdf | ||
| RFP-Grand_Rapids_Infrastructure_Improvements.doc | DOC document |
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
P l o t
D a t e A p r
F i l e
L o c a t i o n W
G
R N
D R
P D
S
U
S D
A
I n f r a s t r u c t u r e
R e n o v D r a w i n g s G d w g
TITLE SHEET
DRAWING TITLE
CHECKED BY:
DRAWN BY:
G001
RGH
CC
GENERAL
G001 TITLE SHEET
ARCHITECTURAL
A101 MAIN LEVEL DEMOLITION PLAN
A201 MAIN LEVEL FLOOR PLAN
A501 ENLARGED DEMOLITION PLANS
A502 ENLARGED FLOOR PLANS
A503 ENLARGED REFLECTED CEILING PLANS
A601 DETAILS & DOOR SCHEDULE
STRUCTURAL
S001 GENERAL STRUCTURAL NOTES
S201 SUPPORT TOWER FRAMING
PLUMBING
MP01 MECHANICAL SYMBOLS & LEGEND SHEET
P100 UNDERGROUND PLUMBING DEMOLITION PLAN
P101 FIRST FLOOR PLUMBING DEMOLITION PLAN
P200 UNDERGROUND PLUMBING PLAN
P201
FIRST FLOOR PLUMBING PLAN, SCHEDULE, AND RISER
MECHANICAL
M101 FIRST FLOOR MECHANICAL DEMOLITION PLAN
M301
FIRST FLOOR MECHANICAL PLAN, ROOF PLAN & SECTIONS
M601 MECHANICAL SECTIONS AND DETAILS
M801 MECHANICAL SCHEDULES
ELECTRICAL
E001 ELECTRICAL SYMBOLS AND LEGEND
E100 MAIN LEVEL ELECTRICAL DEMOLITION PLAN
E101 ENLARGED ELECTRICAL DEMOLITION PLANS
E200 MAIN LEVEL ELECTRICAL PLAN AND PANEL SCHEDULE
E201
ENLARGED ELECTRICAL PLANS, RISER AND SCHEDULES
CD CONSTRUCTION
DOCUMENTS
2019 MAR 22
DESCRIPTION DATE
INFRASTRUCTURE
RENOVATION
MARK
CLIENT
PROJECT DESCRIPTION
CITY
STATE
ISSUE DATES
PROJECT NO: 20185390
GRAND RAPIDS
MINNESOTA
TELE FAX
Grand Forks ND Williston ND Bemidji MN
Fargo ND Minot ND Buenos Aires ARG
Bismarck ND Norwich VT
222 Third Street NW, Bemidji, MN 56601
218.751.0151 218.751.0170
Sioux Falls SD St. Paul MN Fort Collins CO Phoenix AZ
Infrastructure Renovation
Grand Rapids, MN 55744
LIST OF DRAWINGS PROJECT LOCATION MAP
GRAND
EAST GRAND
FORKS
BAGLEY
PARK RAPIDS
THIEF RIVER FALLS
MINNEAPOLIS
ST. PAUL
ROCHESTER
DETROIT LAKES
MAHNOMEN
FARGO, ND
INTERNATIONAL FALLS
DULUTH
2HWY
CROOKSTON
FORKS
GRAND
WALKER
HWY71
PINE RIVER
HWY
CASS LAKE
HWY10
HWY59
HWY10
HWY
STATE MAP
G001
STATE MAP
NTS
G001
PROJECT LOCATION MAP
NTS
BEMIDJI
RAPIDS
CODE ANALYSIS:
LIFE SAFETY LEGEND:'
TDE 100'-0"
PROJECT DESCRIPTION:
CODE BASIS OF DESIGN:
BASIS OF DESIGN:
55335
Architect under the laws of the State of supervision and that I am a duly licensed report was prepared by me or under my direct I hereby certify that this plan, specification, or
Signature:
Print Name:
Minnesota.
Date: License #:
Craig Clark
05/31/2018
AutoCAD SHX Text OCCUPANCY IBC 303.2 GROUP B - BUSINESS GROUP B - BUSINESS GROUP S-2 STORAGE SPECIAL REQUIREMENTS / OCCUPANCIES NONE TYPE OF CONSTRUCTION EXISTING BUILDING MBC TABLE 601 TYPE V-B TYPE V-B ALLOWABLE HEIGHT & AREA OCCUPANCY MBC TABLE 503 MBC TABLE 503 MBC TABLE 503MBC TABLE 503 MBC TABLE 503 MBC TABLE 503BC TABLE 503 MBC TABLE 503 MBC TABLE 503MBC TABLE 503 MBC TABLE 503MBC TABLE 503GROUP B 40 FEET MAX 2 STORIES MAX 9,000 SF MAX 40 FEET MAX 2 STORIES MAX 9,000 SF MAX 2 STORIES MAX 9,000 SF MAX 9,000 SF MAX SPRINKLER INCREASE = 9,000 X 3 = 27,000 SF + 9,000 SF = 36,000 SF TOTAL ACTUAL 15 FEET 1 STORY 14,400 SF 15 FEET 1 STORY 14,400 SF 1 STORY 14,400 SF 14,400 SF GROUP S-2 40 FEET MAX 2 STORIES MAX 13,500 SF MAX 40 FEET MAX 2 STORIES MAX 13,500 SF MAX 2 STORIES MAX 13,500 SF MAX 13,500 SF MAX SPRINKLER INCREASE = 13,500 X 3 = 40,500 SF + 13,500 SF = 54,000 SF TOTAL ACTUAL 15 FEET 1 STORY 4,800 SF 15 FEET 1 STORY 4,800 SF 1 STORY 4,800 SF 4,800 SF SEPARATIONS OCCUPANCY NO OCCUPANCY SEPARATIONS REQUIRED SMOKE COMPARTMENTS NO SMOKE COMPARTMENTS REQUIRED FIRE RESISTANCE PER IBC TABLE 601 BUILDING ELEMENT FR RATING CONCRETE DESIGNFR RATING CONCRETE DESIGNCONCRETE DESIGNSTEEL DESIGN PRIMARY STRUCTURAL FRAME 0 HOUR --- ---0 HOUR --- ------ ------BEARING WALLS 0 HOUR --- --- 0 HOUR --- --- --- --- --- EXTERIOR NON-BEARING 0 HOUR* --- --- 0 HOUR* --- --- --- --- --- INTERIOR NON-BEARING SEE PLANS --- ---SEE PLANS --- ------ ------FLOOR CONSTRUCTION, TYP 0 HOUR --- --- 0 HOUR --- --- --- --- --- ROOF CONSTRUCTION 0 HOUR --- ---0 HOUR --- ------ ------EGRESS OCCUPANT LOADS IBC TABLE 1004.1.2 OCCUPANT LOAD FACTORS OCCUPANCY AREA OLF OL AREA OLF OL OLF OL OL OFFICE 1/100 1/100 STORAGE 1/200 1/200 MECHANICAL 1/300 1/300 EXITS 2 / 68" REQUIRED 8 / 272" 2 / 68" REQUIRED 8 / 272" 8 / 272" PROVIDED DIRECT EXITS FROM GARAGE AND RECEIVING TOTAL NUMBER OF EMPLOYEES +/- 20 ACCESSIBILITY ALL MODIFIED AREAS TO BE COMPLIANT. PLUMBING FIXTURES PER IBC TABLE 2902.1 FACILITY LOAD FACTOR FIXTURES LOAD FACTOR FIXTURES FIXTURES REQUIRED PROVIDEDOCCUPANTS: WOMEN WC'S (B) 1/25 FOR FIRST 50 1 3 1/25 FOR FIRST 50 1 3 1 3 3 1/50 FOR EACH 50 AFTER MEN WC'S (B) 1/25 FOR FIRST 50 1 3 1/25 FOR FIRST 50 1 3 1 3 3 1/50 FOR EACH 50 AFTER WOMEN LAV (B) 1/40 FOR FIRST 80 1 3 1/40 FOR FIRST 80 1 3 1 3 3 1/80 FOR EACH 80 AFTER MEN LAV (B) 1/40 FOR FIRST 80 1 3 1/40 FOR FIRST 80 1 3 1 3 3 1/80 FOR EACH 80 AFTER
AutoCAD SHX Text 2 HOUR FIRE BARRIER 1 HOUR FIRE BARRIER 1 HOUR SMOKE BARRIER NON-RATED SMOKE PARTITION EXIT & DISCHARGE, CLEAR WIDTH IN INCHES EXIT ACCESS DOOR; SMOKE COMPARTMENT, CLEAR WIDTH IN INCHES EXIT SIGN, ILLUMINATED PRIMARY EGRESS PATH / ACCESSIBLE ROUTE AND SECONDARY EGRESS PATH / ACCESSIBLE ROUTE HAZARDOUS AREA / INCIDENTAL USE, TABLE 509 TRAVEL DISTANCE, AS NOTED SUITE BOUNDARY FIRE EXTINGUISHER CABINETS, SEMI RECESSED UNO
AutoCAD SHX Text RENOVATION OF TWO SOIL GRINDING ROOMS, ADDITION OF MOBILE STORAGE SHELVING IN TWO STORAGE ROOMS, RENOVATION OF COOLER ROOM TO INCLUDE LARGER COOLER, AND RELOCATE ONE DOOR.
AutoCAD SHX Text APPLICABLE CODES AND GOVERNING STANDARDS BUILDING CODE 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL BUILDING CODE FIRE CODE 2015 INTERNATIONAL FIRE CODE 2015 INTERNATIONAL FIRE CODE MECHANICAL CODE 2015 INTERNATIONAL MECHANICAL 2015 INTERNATIONAL MECHANICAL CODE FUEL GAS CODE 2015 INTERNATIONAL FUEL GAS CODE 2015 INTERNATIONAL FUEL GAS CODE ENERGY CODE 2015 INTERNATIONAL ENERGY 2015 INTERNATIONAL ENERGY CONSERVATION CODE PLUMBING CODE INTERNATIONAL PLUMBING COD E INTERNATIONAL PLUMBING COD E E ELECTRICAL CODE NATIONAL ELECTRIC CODE NATIONAL ELECTRIC CODE ACCESSIBILITY FEDERAL ARCHITECTURAL BARRIERS FEDERAL ARCHITECTURAL BARRIERS ACT LIFE SAFETY NFPA 101NFPA 101
AutoCAD SHX Text OCCUPANCY: IBC 303.3 GROUP B - BUSINESS IBC 303.3 GROUP B - BUSINESS CONSTRUCTION: V-B PER IBC 602.2 AND TABLE 601 V-B PER IBC 602.2 AND TABLE 601 FIRE SPRINKLERS: BUILDING NOT SPRINKLED BUILDING NOT SPRINKLED
A101
FIRST FLOOR DEMOLITION PLAN
1/8" = 1'-0"
N
KEY PLAN
NTS
N
A501
A501
A501
P l o t
D a t e M a r
F i l e
L o c a t i o n W
G
R N
D R
P D
S
U
S D
A
I n f r a s t r u c t u r e
R e n o v D r a w i n g s A d w g
MAIN LEVEL
DEMOLITION PLAN
DRAWING TITLE
CHECKED BY:
DRAWN BY:
A101
RGH
CC
CD CONSTRUCTION
DOCUMENTS
2019 MAR 22
DESCRIPTION DATE
INFRASTRUCTURE
RENOVATION
MARK
CLIENT
PROJECT DESCRIPTION
CITY
STATE
ISSUE DATES
PROJECT NO: 20185390
GRAND RAPIDS
MINNESOTA
TELE FAX
Grand Forks ND Williston ND Bemidji MN
Fargo ND Minot ND Buenos Aires ARG
Bismarck ND Norwich VT
222 Third Street NW, Bemidji, MN 56601
218.751.0151 218.751.0170
Sioux Falls SD St. Paul MN Fort Collins CO Phoenix AZ
55335
Architect under the laws of the State of supervision and that I am a duly licensed report was prepared by me or under my direct I hereby certify that this plan, specification, or
Signature:
Print Name:
Minnesota.
Date: License #:
Craig Clark
05/31/2018
AutoCAD SHX Text
FREEZER
AutoCAD SHX Text
AutoCAD SHX Text
DRY
STORAGE
A201
MAIN LEVEL FLOOR PLAN
1/8" = 1'-0"
N
KEY PLAN
NTS
N
A502
A502
A502
3 5/8" METAL STUDS @ 16" OC,
5/8" TYPE "X" GYP BD EA SIDE,
SMOOTH FRP @ ROOM SIDE
1 5/8" METAL STUDS @ 16" OC,
1 1/2" RIGID INSUL, BATT INSUL IN STUD
CAVITY, VAPOR BARRIER, 5/8" TYPE "X" GWB,
SMOOTH FRP @ ROOM SIDE
2x6 WD STUDS @ 16" OC, 5/8" TYPE "X" GWB EA SIDE
3 5/8" METAL STUDS @ 16" OC,
5/8" TYPE "X" GYP BD EA SIDE,
SMOOTH FRP @ ROOM SIDE
1 5/8" METAL STUDS @ 16" OC,
1 1/2" RIGID INSUL, BATT INSUL IN STUD
CAVITY, VAPOR BARRIER, 5/8" TYPE "X" GWB,
SMOOTH FRP @ ROOM SIDE
2x6 WD STUDS @ 16" OC, 5/8" TYPE "X" GWB EA SIDE
A201
WALL TYPES
1 1/2" = 1'-0"
P l o t
D a t e M a r
F i l e
L o c a t i o n W
G
R N
D R
P D
S
U
S D
A
I n f r a s t r u c t u r e
R e n o v D r a w i n g s A d w g
MAIN LEVEL FLOOR
PLAN
DRAWING TITLE
CHECKED BY:
DRAWN BY:
A201
RGH
CC
CD CONSTRUCTION
DOCUMENTS
2019 MAR 22
DESCRIPTION DATE
INFRASTRUCTURE
RENOVATION
MARK
CLIENT
PROJECT DESCRIPTION
CITY
STATE
ISSUE DATES
PROJECT NO: 20185390
GRAND RAPIDS
MINNESOTA
TELE FAX
Grand Forks ND Williston ND Bemidji MN
Fargo ND Minot ND Buenos Aires ARG
Bismarck ND Norwich VT
222 Third Street NW, Bemidji, MN 56601
218.751.0151 218.751.0170
Sioux Falls SD St. Paul MN Fort Collins CO Phoenix AZ
55335
Architect under the laws of the State of supervision and that I am a duly licensed report was prepared by me or under my direct I hereby certify that this plan, specification, or
Signature:
Print Name:
Minnesota.
Date: License #:
Craig Clark
05/31/2018
A501
ENLARGED DEMOLITION PLAN (BASE BID)
1/4" = 1'-0"
N
A501
ENLARGED DEMOLITION PLAN (ALT. BID #1)
1/4" = 1'-0"
N
A501
ENLARGED DEMOLITION PLAN (ALT. BID #2)
1/4" = 1'-0"
N
DEMOLITION NOTES:
CONTRACTOR TO DISASSEMBLE SHELVING UNITS AND RETURN TO OWNER. KEEP
PARTS TOGETHER BY SHELF OR LABEL PRIOR TO DISASSEMBLY.
REMOVE EXISTING DOORS AND FRAME. TURN ENTIRE ASSEMBLY 180° AND REINSTALL
INTACT. PATCH WALLS AND PAINT TO MATCH EXISTING FINISHES.
REMOVE EXISTING COUNTERS & FRAMING. ALT BID TO RE-LAMINATE AND REINSTALL.
REMOVE EXISTING UNDER COUNTER DUST FILTRATION SYSTEM.
REMOVE EXISTING DUST COLLECTION SYSTEM COMPLETE. PATCH ALL PENETRATIONS
IN ROOM AND EXTERIOR WALLS.
REMOVE SINK BASE AND PLUMBING FIXTURES. CAP PLUMBING AT THE FACE OF WALL,
CUT COUNTERTOP AND LAMINATE CUT END. PROVIDE FINISHED END PANEL ON
EXPOSED CABINET.
REMOVE CABINETS AT WALK-IN COOLER.
REMOVE UPPER AND LOWER CABINETS AND PLUMBING FIXTURES.
OWNER TO RELOCATE OVEN, FAN AND DUCTWORK. CONTRACTOR TO PATCH CEILING
AND ROOF.
REMOVE EXISTING FUME HOOD.
REMOVE EXISTING DOOR AND FRAME.
CUT OPENING IN EXISTING WALL FOR NEW DOOR AND FRAME.
REMOVE EXISTING WALK-IN REFRIGERATOR.
SAW-CUT SLAB FOR INSTALL OF NEW COLLER/FREEZER. SEE PLUMBING FOR
ADDITIONAL INFORMATION.
EXISTING CABINETS TO REMAIN.
REMOVE EXISTING EYEWASH / EMERGENCY SHOWER.
REMOVE EXISTING SLAB FOR INSTALLATION OF NEW RAMPS
GC TO SAW CUT FLOOR FOR PLUMBING INSTALL. SEE PLUMBING DRAWINGS FOR EXACT
ROUTE
REMOVE SKYLIGHT. CURB TO REMAIN AND BE RE-USED BY MECHANICAL. SEE MECH
FOR ADDITIONAL INFO.
NEW SUPPORT BY GC FOR MAKE-UP AIR UNIT. SEE STRUCTURAL FOR DESIGN.
4'-9"
1 11
3 3
5 5
4 4
1'-6"
17 17
P l o t
D a t e M a r
F i l e
L o c a t i o n W
G
R N
D R
P D
S
U
S D
A
I n f r a s t r u c t u r e
R e n o v D r a w i n g s A d w g
ENLARGED
DEMOLITION PLANS
DRAWING TITLE
CHECKED BY:
DRAWN BY:
A501
RGH
CC
CD CONSTRUCTION
DOCUMENTS
2019 MAR 22
DESCRIPTION DATE
INFRASTRUCTURE
RENOVATION
MARK
CLIENT
PROJECT DESCRIPTION
CITY
STATE
ISSUE DATES
PROJECT NO: 20185390
GRAND RAPIDS
MINNESOTA
TELE FAX
Grand Forks ND Williston ND Bemidji MN
Fargo ND Minot ND Buenos Aires ARG
Bismarck ND Norwich VT
222 Third Street NW, Bemidji, MN 56601
218.751.0151 218.751.0170
Sioux Falls SD St. Paul MN Fort Collins CO Phoenix AZ
55335
Architect under the laws of the State of supervision and that I am a duly licensed report was prepared by me or under my direct I hereby certify that this plan, specification, or
Signature:
Print Name:
Minnesota.
Date: License #:
Craig Clark
05/31/2018
AutoCAD SHX Text
FREEZER
AutoCAD SHX Text
AutoCAD SHX Text
DRY
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
PLANT
AutoCAD SHX Text
PREP
AutoCAD SHX Text
AutoCAD SHX Text
SOIL
AutoCAD SHX Text
PREP
AutoCAD SHX Text
AutoCAD SHX Text
STOR
AutoCAD SHX Text
AutoCAD SHX Text
STOR
AutoCAD SHX Text
AutoCAD SHX Text
LONG
AutoCAD SHX Text
TERM
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
CORR
rsindt Text Box
REVISED: 04/12/2019
A502
ENLARGED FLOOR PLAN (BASE BID)
1/4" = 1'-0"
N
A502
ENLARGED FLOOR PLAN (ALT. BID #1)
1/4" = 1'-0"
N
A502
ENLARGED FLOOR PLAN (ALT. BID #2)
1/4" = 1'-0"
N
REFERENCE NOTES:
REINSTALLED DOORS AND FRAME. PATCH AND REPAIR WALLS AND PAINT TO MATCH.
RE-SET FLUSH BOLT RECEIVER IN CONC AND PATCH CONC DAMAGE W/ NON-SHRINK
GROUT.
NEW CONC SLAB @ NEW COOLER/FREEZER, SEE DETAIL 7/A601.
NEW WALK-IN COOLER/FREEZER. SEE SPEC FOR TYPE, SEE MECH FOR CONDENSER
LOCATION.
FLOOR DRAIN, SEE PLUMBING DRAWINGS.
INFILL EXISTING DOOR OPENING WITH SIMILAR CONSTRUCTION, PAINT BOTH SIDES TO
FINISH TO MATCH EXISTING.
CUT EXISTING FLOOR SLAB AND PROVIDE NEW RAMP @ 1:12 SLOPE DOWN TO EXISTING
FLOOR LEVEL. APPROX 6' LONG, SEE DETAIL 6/A601.
NEW WOOD DOOR IN HM FRAME, SEE DETAILS 1 & 2/A601 AND SPEC.
PLASTIC LAMINATE OVER PLYWOOD TOP, 24" DEEP W/ BACKSPLASH
FINISH END PANEL OF CABINET FROM REMOVAL OF SINK BASE. RE-LAMINATE EDGE OF
COUNTERTOP WHERE CUT.
SKYLIGHT ABOVE - SEE NOTES ON REFLECTED CEILING PLAN SHEET A503.
PATCH WALLS AND PAINT TO MATCH AT REMOVED MILLWORK COUNTERS AND
CABINETS
NEW WINDOWS IN EXISTING OPENINGS - CONTRACTOR TO VERIFY ROUGH OPENINGS
AFTER DEMO OF OLD WINDOWS. ONE WINDOW OCCURS IN FORMER DOOR OPENING.
CONTRACTOR TO PROVIDE FIELD MEASUREMENTS TO VERIFY NEW WINDOW SIZES. AT
WINDOW IN DOOR INFILL LOCATION, ADDITIONAL BLOCKING WILL BE REQUIRED.
A502
4 MIR
A502
COOLER
FREEZER
1'-6"
6'-0"
4'-9"
A502
INTERIOR ELEVATION
1/4" = 1'-0"
4'-0"3'-0"3'-0"3'-0"
SOUTHMATLROOM NAMERM # BASE NORTH EAST
FLOOR WALL
MATLWEST HEIGHT NOTE
CEILING
NOTES:
1. VCT AT NEW RAMPS AND LOCATIONS DISTURBED BY CONSTRUCTION. MATCH EXISTING.
DRY STORAGE101 EX EX EXEX
LONG TERM STORAGE102
PLANT PREP114 PNT CONCVINYL FRP FRP
SOIL PREP115
STORAGE120 EX EX
8'-0"
12'-0"
8'-0"
PNT
EX
ROOM FINISH SCHEDULE
VCT VINYL
EX EX
FRP
EX
EX
FRP
EX
F
F
A601
A601
UP
U P
FLAT
A601
3,5
A601
EX EX EXEX 12'-0"EX EX EX --
PNT CONCVINYL FRP FRP 8'-0"PNTFRP FRP
13'-6"
COUNTERTOP
SUPPORTS
PLASTIC LAMINATE
COUNTERTOP
P. LAM VERTICAL PANEL AT
TRANSITION
6'-0"
8 8
A601
INTERMEDIATE
SUPPORTS
12 12
3,5
A601
A601
114A
F
ROOM 101
ROOM 102
P l o t
D a t e M a r
F i l e
L o c a t i o n W
G
R N
D R
P D
S
U
S D
A
I n f r a s t r u c t u r e
R e n o v D r a w i n g s A d w g
ENLARGED FLOOR
PLANS
DRAWING TITLE
CHECKED BY:
DRAWN BY:
A502
RGH
CC
CD CONSTRUCTION
DOCUMENTS
2019 MAR 22
DESCRIPTION DATE
INFRASTRUCTURE
RENOVATION
MARK
CLIENT
PROJECT DESCRIPTION
CITY
STATE
ISSUE DATES
PROJECT NO: 20185390
GRAND RAPIDS
MINNESOTA
TELE FAX
Grand Forks ND Williston ND Bemidji MN
Fargo ND Minot ND Buenos Aires ARG
Bismarck ND Norwich VT
222 Third Street NW, Bemidji, MN 56601
218.751.0151 218.751.0170
Sioux Falls SD St. Paul MN Fort Collins CO Phoenix AZ
55335
Architect under the laws of the State of supervision and that I am a duly licensed report was prepared by me or under my direct I hereby certify that this plan, specification, or
Signature:
Print Name:
Minnesota.
Date: License #:
Craig Clark
05/31/2018
AutoCAD SHX Text
AutoCAD SHX Text
DRY
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
PLANT
AutoCAD SHX Text
PREP
AutoCAD SHX Text
AutoCAD SHX Text
SOIL
AutoCAD SHX Text
PREP
AutoCAD SHX Text
AutoCAD SHX Text
STOR
AutoCAD SHX Text
AutoCAD SHX Text
STOR
AutoCAD SHX Text
AutoCAD SHX Text
LONG
AutoCAD SHX Text
TERM
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text 114A
AutoCAD SHX Text
CLOS
rsindt
A503
ENLARGED REFLECTED CEILING PLAN (BASE BID)
1/4" = 1'-0"
N
A503
ENLARGED REFLECTED CEILING PLAN (ALT. BID #1)
1/4" = 1'-0"
N
A503
ENLARGED REFLECTED CEILING PLAN (ALT. BID #2)
1/4" = 1'-0"
N
COOLER
FREEZER
LEGEND
DIFFUSER-SUPPLY
SEE MECH
DIFFUSER-RETURN
SEE MECH
LIGHTS
SEE ELEC
SMOKE DETECTOR
SEE ELEC
SPRINKLER HEAD
SEE MECH
SPEAKER
SEE ELEC
ACT CEILING GRID
SMOKE RESISTIVE CONSTRUCTION
SMOKE BARRIER
1 HOUR FIRE SEPARATION
S
S
GWB CLG/SOFFIT
A601
REFERENCE NOTES:
INFILL EXISTING SKYLIGHT. SEE DETAIL 8/A601.
NEW LIGHTS, SEE ELECTRICAL FOR TYPE.
P l o t
D a t e M a r
F i l e
L o c a t i o n W
G
R N
D R
P D
S
U
S D
A
I n f r a s t r u c t u r e
R e n o v D r a w i n g s A d w g
ENLARGED
REFLECTED CEILING
PLANS
DRAWING TITLE
CHECKED BY:
DRAWN BY:
A503
RGH
CC
CD CONSTRUCTION
DOCUMENTS
2019 MAR 22
DESCRIPTION DATE
INFRASTRUCTURE
RENOVATION
MARK
CLIENT
PROJECT DESCRIPTION
CITY
STATE
ISSUE DATES
PROJECT NO: 20185390
GRAND RAPIDS
MINNESOTA
TELE FAX
Grand Forks ND Williston ND Bemidji MN
Fargo ND Minot ND Buenos Aires ARG
Bismarck ND Norwich VT
222 Third Street NW, Bemidji, MN 56601
218.751.0151 218.751.0170
Sioux Falls SD St. Paul MN Fort Collins CO Phoenix AZ
55335
Architect under the laws of the State of supervision and that I am a duly licensed report was prepared by me or under my direct I hereby certify that this plan, specification, or
Signature:
Print Name:
Minnesota.
Date: License #:
Craig Clark
05/31/2018
AutoCAD SHX Text
AutoCAD SHX Text
DRY
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
PLANT
AutoCAD SHX Text
PREP
AutoCAD SHX Text
AutoCAD SHX Text
SOIL
AutoCAD SHX Text
PREP
AutoCAD SHX Text
AutoCAD SHX Text
STOR
AutoCAD SHX Text
AutoCAD SHX Text
STOR
AutoCAD SHX Text
AutoCAD SHX Text
LONG
AutoCAD SHX Text
TERM
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text 114A
AutoCAD SHX Text
CLOS
rsindt
2"
SEE DR
SCHED
2"
F
A601
DOOR & FRAME TYPE
1/4" = 1'-0"
DOOR SIZEDR #
FRAME
MATL
WD
DOOR
GL MATL
DETAILS SEE DWG:
EL HEAD JAMB SILL
RATING
FIRE
A601
HARDWARE
DOOR
NOTE
NOTES:
1. REMOVE DOORS AND FRAME AND TURN FRAME 180 DEGREES AND REINSTALL IN SAME LOCATION. PREP FLOOR FOR
FLUSH BOLTS AND PATCH FLOOR FROM OLD FLUSH BOLT RECEIVER.
-- HM 1
DOOR SCHEDULE
--(PR) 3-0x7-0x1 3/4
120 WD -- -- ---- HM 1 10/A601 10/A601 23-0x7-0x1 3/4
2/A601 1/A601
A601
WINDOW TYPE
1/4" = 1'-0"
M A
T C
H
E X
I S T
MATCH EXIST.
MATCH EXISTING ALUMINUM
CLAD WINDOWS BY MARVIN
WINDOWS. NEW WINDOWS
NON-OPERABLE
A
114A WD -- -- ---- HM 1 2/A601 1/A601 12-6x7-0x1 3/4
7 3/4"
7 3/4"
SOLID SURFACE SILL - WILSONART,
PIONITE OR CORIAN
SEALANT
EX CMU
BATT INSUL W/
VAPOR BARRIER
5/8" TYPE 'X' GWB
SMOOTH FRP
5/8" TYPE 'X' GWB
SEALANT
NEW WDW. MATCH EXISTING
PROFILE BY MARVIN WINDOWS
1 5/8" MTL STUDS
@ 16" OC
EX CMU
BATT INSUL W/
VAPOR BARRIER
5/8" TYPE 'X' GWB
SMOOTH FRP
MTL CORNER BEAD
5/8" TYPE 'X' GWB
SEALANT
NEW WDW
1 5/8" MTL STUDS
@ 16" OC
NEW WDW
EX CMU
BATT INSUL W/
VAPOR BARRIER
5/8" TYPE 'X' GWB
SMOOTH FRP
1 5/8" MTL STUDS
@ 16" OC
A601
INT DOOR JAMB
1 1/2" = 1'-0"
A601
INT DOOR HEAD
1 1/2" = 1'-0"
A601
WDW SILL
1 1/2" = 1'-0"
A601
WDW JAMB
1 1/2" = 1'-0"
A601
WDW HEAD
1 1/2" = 1'-0"
5/8" GWB
2x6 WD STUDS
SLNT @ ALL EDGES
HM FRAME
DOOR
5/8" GWB
WD STUDS, DBL STUDS @ JAMBS - SEE
WALLTYPES FOR WALL THICKNESS
SLNT @ ALL EDGES
HM FRAME
DOOR
3 ANCHORS PER JAMB,
SCREWED TO STUDS
A601
RAMP SECTION
1 1/2" = 1'-0"
6'-0"
EXISTING SLAB
DRILL & DOWEL #4 REBAR @
12" OC, MIN 2 BARS @ EA END
OF RAMP, EMBED MIN 6" &
SET IN NON-SHRINK GROUT
EXISTING SLAB
NEW SLAB/RAMP.
4,000 PSI CONC.
M I N
FORM SLOPE W/
SAND OR CONC
DRILL & DOWEL #4 REBAR @
12" OC, MIN 2 BARS @ EA END
OF RAMP, EMBED MIN 6" &
SET IN NON-SHRINK GROUT
EXISTING SLAB
PRE-FABRICATED WALK-IN
(4" THICK WALLS)
10MM VAPOR BARRIER
2 LAYERS OF 2" THICK SHEET
URETHANE 25 PSI MIN. W/
STAGGERED JOINTS
2x8 10 lbs DENSITY RIGID
FOAM BREAKER STRIP
15 lb FELT OVER INSUL
A601
COOLER / FREEZER FLOOR DETAIL
1 1/2" = 1'-0"
A601
SKYLIGHT INFILL
1 1/2" = 1'-0"
EX SKYLIGHT OPENING
5/8" TYPE 'X' GWB.
LEVEL WITH EXIST.
CEILING. PAINT TO
MATCH
2X4 STUDS @ 16"
OC
EXIST. CEILING
4" CONC. SLAB W/ #4 REBAR
@ 24" O.C. EACH WAY
SEAL CONCRETE
2'-1"
S E E
E L E V
P-LAM OVER 2 LAYERS OF
3/4" PLYWOOD
COUNTERTOP
P-LAM ON 1" PLYWOOD
AT ENTIRE PERIMETER
2'-0"
4" BACKSPLASH
2" X 2" WELDED
TUBE STEEL FRAME
A601
COUNTER SECTION
1 1/2" = 1'-0"
2" RUBBER SHOE AT EACH
VERTICAL SUPPORT
WD STUDS, DBL STUDS @ JAMBS - SEE
WALLTYPES FOR WALL THICKNESS
NEW ALUM. SIDING AND DRIP EDGE -
PART OF SEPARATE PROJECT
NEW ALUM. SIDING AND DRIP EDGE -
PART OF SEPARATE PROJECT
NEW INSULATION, ALUM. SIDING
AND DRIP EDGE - PART OF SEPARATE
PROJECT
BLOCKING AS REQUIRED TO FIT WINDOW
INTO EXISTING MASONRY OPENING
EX CMU
5 3/4"
SLNT @ ALL EDGES
HM FRAME
DOOR
A601
DOOR HEAD (JAMB SIMILAR)
1 1/2" = 1'-0"
P l o t
D a t e M a r
F i l e
L o c a t i o n W
G
R N
D R
P D
S
U
S D
A
I n f r a s t r u c t u r e
R e n o v D r a w i n g s A d w g
DETAILS & DOOR
SCHEDULE
DRAWING TITLE
CHECKED BY:
DRAWN BY:
A601
RGH
CC
CD CONSTRUCTION
DOCUMENTS
2019 MAR 22
DESCRIPTION DATE
INFRASTRUCTURE
RENOVATION
MARK
CLIENT
PROJECT DESCRIPTION
CITY
STATE
ISSUE DATES
PROJECT NO: 20185390
GRAND RAPIDS
MINNESOTA
TELE FAX
Grand Forks ND Williston ND Bemidji MN
Fargo ND Minot ND Buenos Aires ARG
Bismarck ND Norwich VT
222 Third Street NW, Bemidji, MN 56601
218.751.0151 218.751.0170
Sioux Falls SD St. Paul MN Fort Collins CO Phoenix AZ
55335
Architect under the laws of the State of supervision and that I am a duly licensed report was prepared by me or under my direct I hereby certify that this plan, specification, or
Signature:
Print Name:
Minnesota.
Date: License #:
Craig Clark
05/31/2018
DESIGN CODES - ALL CODES LATEST EDITION UON:
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION, 15th ED., ASD
AWS AMERICAN WELDING SOCIETY STANDARDS FOR WELDING AS MODIFIED BY AISC SPEC.
IBC INTERNATIONAL BUILDING CODE, IBC 2015
ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS - MINIMUM DESIGN LOADS FOR BUILDINGS
AND OTHER STRUCTURES (ASCE 7-10)
ACI AMERICAN CONCRETE INSTITUTE, 318-14
CRSI CONCRETE REINFORCING STEEL INSTITUTE MANUAL OF STANDARD PRACTICE
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
NOTE: CODES ARE AMENDED AS REQUIRED BY THE STATE BUILDING CODE WITH JURISDICTION
GOVERNING THE PROJECT LOCATION.
DESIGN LOADS:
THE DESIGN INCLUDED HEREWITH IS BASED ON THE FOLLOWING DESIGN LOADS
SUPERIMPOSED ON THE COMPLETED BUILDING.
SNOW LOADS:
FLAT ROOF SNOW LOAD (BUILDING) Pf = 42 PSF GROUND SNOW LOAD Pg = 70 PSF SNOW EXPOSURE FACTOR Ce = 1.0 THERMAL FACTOR Ct = 1.0 SNOW LOAD IMPORTANCE FACTOR l = 1.0 (OCCUPANCY CATEGORY II)
DRIFT LOADS AS PER ASCE 7-10
ROOF DEAD LOADS:
AT FLAT ROOF LOCATIONS =15 PSF ROOFING, 10 PSF COLLATTERAL
DEAD LOAD
WALLS - MWFRS:
EXTERIOR LATERAL WIND PRESSURE - MWFRS = 16 PSF FROM 0-20 FEET HIGH
WIND LOADS:
WIND DESIGN CRITERIA: (PER ASCE 7-10)
BASE WIND SPEED = 115 MPH (3 SECOND GUST)
IMPORTANCE FACTOR = 1.0 (OCCUPANCY CATEGORY II)
EXPOSURE = C
INTERNAL PRESSURE COEFFICIENT = ±0.18
NET UPLIFT = 18 PSF ON ROOF AREAS
ALLOWABLE SOIL BEARING PRESSURE = 3500 PSF
GENERAL REQUIREMENTS
1. GENERAL CONTRACTOR TO PROVIDE AN AS-BUILT SET OF DRAWINGS FOR EACH SHEET TO
EAPC AT THE COMPLETION OF THE PROJECT WITH ALL CHANGES MADE IN THE FIELD
CLEARLY MARKED ON IT.
2. CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE ALL STRUCTURAL SYSTEMS WITH
ARCHITECTURAL FINISHES, DETAILS, ETC. CONTRACTOR SHALL COORDINATE MECHANICAL
AND ELECTRICAL SYSTEMS TO AVOID CUTTING OR ALTERING STRUCTURAL MEMBERS IN
ANY MANNER. DO NOT FIELD CUT ANY STRUCTURAL STEEL BEAM, COLUMN, JOIST, ETC.
WITHOUT WRITTEN APPROVAL FROM ENGINEER OF RECORD.
3. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS PREPARED AS OUTLINED IN THE
SPECIFICATIONS MANUAL PRIOR TO FABRICATING ANY STRUCTURAL MEMBER. FIELD
MODIFICATIONS ARE NOT ALLOWED WITHOUT WRITTEN APPROVAL FROM ENGINEER OF
RECORD.
4. THE STRUCTURAL DESIGN IS BASED ONLY ON THE BUILDING IN ITS COMPLETED STATE.
CONTRACTOR SHALL TAKE WHATEVER PRECAUTIONS ARE NECESSARY TO WITHSTAND ALL
HORIZONTAL AND VERTICAL LOADINGS THAT MAY BE ENCOUNTERED DURING THE
CONSTRUCTION PRIOR TO COMPLETION OF THE BUILDING.
5. THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION
SAFETY. PROVIDE CONSTRUCTION SHORING AND BRACING AS NECESSARY TO COMPLETE
THE INSTALLATION OF ALL STRUCTURAL MEMBERS/ FOOTINGS/ ETC.
6. NO OPENINGS OR SLEEVES (EXCEPT AS DETAILED) SHALL BE CUT OR PROVIDED IN
FOOTINGS, WALLS OR STRUCTURAL FLOOR CONSTRUCTION WITHOUT APPROVAL.
7. REFER TO ARCHITECTURAL PLANS FOR DETAILS OF CONCRETE, REVEALS, NOTCHES,
REGLETS, DRIPS, BLOCKOUTS AT DOORWAYS, AND WATERPROOFING/DRAINAGE BOARD.
8. CONTRACTOR SHALL EMPLOY AND PAY FOR SERVICES OF AN INDEPENDENT TESTING
AGENCY TO PERFORM SPECIFIED TESTING AND SPECIAL INSPECTION AS REQUIRED PER THE
TECHNICAL SPECIFICATIONS OR AS SPECIFICALLY NOTED.
9. CONTRACTOR SHALL BE RESPONSIBLE TO NOTIFY AND COORDINATE INDEPENDENT
TESTING AGENCY WORK DURING CONSTRUCTION. EMPLOYMENT OF AGENCY IN NO WAY
RELIEVES CONTRACTOR OF OBLIGATION TO PERFORM WORK IN ACCORDANCE WITH
REQUIREMENTS OF CONTRACT DOCUMENTS.
10. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING DIMENSIONS, ELEVATIONS, AND
CONDITIONS PRIOR TO BEGINNING WORK. REPORT ANY DISCREPANCIES TO A/E.
11. TESTING AGENCIES SHALL PROMPTLY SUBMIT COPIES OF SPECIAL INSPECTION AND
TESTING REPORT TO ENGINEER OF RECORD UON.
12. RECESSED FLOOR FOR TILE - SEE ARCHITECTURAL DRAWINGS FOR RECESS DEPTH &
LOCATION.
13. ALL FOOTINGS SHALL REST ON UNDISTURBED SOIL OR APPROVED FILL COMPACTED TO A
MINIMUM OF 95% OF MAXIMUM DENSITY.
14. ALL FOOTINGS TO BE CENTERED UNDER COLUMNS OR WALLS UNLESS NOTED.
15. CONTRACTOR SHALL TAKE 3 CONCRETE CYLINDERS, DATED AND CURED SIMILAR TO SLAB
CONDITIONS AND STORED FOR POSSIBLE TESTING.
MATERIAL SPECIFICATIONS:
SEE SPECIFICATIONS FOR COMPLETE SPECIFICATIONS
STRUCTURAL STEEL:
HSS SQUARE/RECTANGULAR SECTIONS ASTM A500 GRADE B (Fy=46 KSI) PLATES/ANGLES/CHANNELS ASTM A36 (Fy=36 KSI) MISCELLANEOUS SHAPES ASTM A36 (Fy=36 KSI)
HIGH STRENGTH BOLTS ASTM A325 TYPE N, UNLESS OTHERWISE
NOTED
WELDING ELECTRODES E70XX
ANCHOR RODS ASTM F1554 GR 36
CONCRETE FASTENERS HILTI HUS-H, SIMPSON TITEN HD
CHEMICAL ANCHORS SIMPSON ACRYLIC TIE, HILTI HSE 2411 OR
FASTENAL PROPOXY 300
THREADED RODS FOR CHEMICAL ANCHORS SEE SPEC 05 1200
COLD FORM FRAMING SEE SPEC 05 4000
CONCRETE:
REINFORCING BARS ASTM A615 GR 60, DEFORMED, FABRICATE TO
CRSI STANDARDS
WELDED WIRE REINFORCING (W.W.R.) ASTM A185, AS DRAWN
WELDED REBAR ASTM A706, GR 60, DEFORMED
CONCRETE (28 DAY COMPRESSIVE STRENGTH):
FOOTINGS/FOUNDATION WALLS/PIERS/SLABS f'c = 3500 PSI
SPECIAL INSPECTION/TESTING:
1. SPECIAL INSPECTION/TESTING REPORT SHALL INCLUDE THE FOLLOWING INFORMATION:
• DATE REPORT IS ISSUED.
• PROJECT TITLE AND NUMBER.
• NAME OF INSPECTOR OR TESTING TECHNICIAN.
• DATE AND TIME OF SAMPLING OR INSPECTION.
• IDENTIFICATION OF PRODUCT AND SPECIFICATIONS SECTION.
• LOCATION IN THE PROJECT.
• TYPE OF TEST/INSPECTION.
• RESULTS OF TEST/INSPECTION.
• CONFORMANCE WITH CONTRACT DOCUMENTS.
• DATE OF TEST/INSPECTION.
• INTERPRETATION OF RESULTS WHEN REQUESTED BY ENGINEER OF RECORD.
2. RE-TESTING OF MATERIAL OR RE-INSPECTION OF WORK REQUIRED BECAUSE OF NON-
CONFORMANCE TO SPECIFIED REQUIREMENTS SHALL BE PERFORMED BY THE SAME AGENCY
AND SHALL BE PAID FOR BY THE CONTRACTOR.
3. SPECIAL INSPECTIONS AND TESTING AGENCIES SHALL PERFORM WORK IN ACCORDANCE
WITH CURRENT TESTING STANDARDS. FREQUENCY AND AREAS OF SPECIAL INSPECTION AND
TESTING SHALL FOLLOW SPECIAL INSPECTION AND TESTING SCHEDULE INCLUDED WITH
CONTRACT DOCUMENTS.
4. SPECIAL INSPECTIONS SHALL BE THE NORMAL CONSTRUCTION QUALITY CONTROL TESTING
INDICATED IN EACH SPECIFICATION SECTION.
5. CONTRACTOR SHALL BE RESPONSIBLE TO NOTIFY AND COORDINATE INDEPENDENT TESTING
AGENCY AND INDEPENDENT SPECIAL INSPECTION AGENCY WORK DURING CONSTRUCTION.
EMPLOYMENT OF AGENCY IN NO WAY RELIEVES CONTRACTOR OF OBLIGATION TO PERFORM
WORK IN ACCORDANCE WITH REQUIREMENTS OF CONTRACT DOCUMENTS.
6. SPECIAL INSPECTION AND TESTING AGENCIES SHALL PROMPTLY SUBMIT COPIES OF SPECIAL
INSPECTION AND TESTING REPORT TO ENGINEER OF RECORD UON.
STRUCTURAL ABBREVIATIONS
AB ANCHOR BOLT
ADDL ADDITIONAL
ADH ADHESIVE
ADJ ADJUSTABLE
ADJC ADJACENT
AES ARCHITECTURALLY EXPOSED
FABRICATIONS STEEL
AESS ARCHITECTURALLY EXPOSED
STRUCTURAL STEEL
AFF ABOVE FINISHED FLOOR
AL ALUMINUM
ANC ANCHOR(AGE)
APPROX APPROXIMATE
ARCH ARCHITECT(URAL)
ASSY ASSEMBLY
A
MAS MASONRY
MAX MAXIMUM
MC MISCELLANEOUS CHANNEL
MFR MANUFACTURER
MECH MECHANICAL
MEZZ MEZZANINE
MIN MINIMUM
MISC MISCELLANEOUS
MTL METAL
M
BF BOTH FACES
BFE BOTTOM OF FOOTING
ELEVATION
BLDG BUILDING
BLK(G) BLOCK(ING)
BM BEAM
BOT BOTTOM
BP BENT PLATE
BRDG BRIDGING
BRG BEARING
BRK BRICK
BT BENT
BTOB BACK-TO-BACK
B
C AMERICAN STANDARD
CHANNEL
C/C CENTER TO CENTER
CAP CAPACITY
CF CUBIC FEET
CHAM CHAMFER
CHKD CHECKED
CIP CAST IN PLACE
CJ CONTROL/CONSTRUCTION
JOINT
CJP COMPLETE JOINT
PENETRATION
CL CENTERLINE
CLR CLEAR(ANCE)
CM CORRUGATED METAL
CMU CONCRETE MASONRY UNIT
COL COLUMN
COMP COMPOSITE
CONC CONCRETE
CONN CONNECT(ION)
CONST CONSTRUCTION
CONT CONTINU(E) (OUS) (ATION)
CONTR CONTRACTOR
COORD COORDINATE
C
D&E DRILL AND EPOXY GROUT
DBA DEFORMED BAR ANCHOR
DBE DECK BEARING ELEVATION
DBL DOUBLE
DET DETAIL
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DL DEAD LOAD
DO DITTO
DR DOOR
DT DOUBLE TEE/DRAIN TILE
DWG(S) DRAWING(S)
DWL DOWEL (REBAR)
D
EA EACH
EB EXPANSION BOLT
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
EQ EQUAL
EQP EQUIPMENT
ES EACH SIDE
ETR EXISTING TO REMAIN
EW EACH WAY
EX EXISTING
EXP EXPOSED/EXPANSION
E
FB FACE BRICK
FD FLOOR DRAIN
FDN FOUNDATION
FFE FINISHED FLOOR ELEVATION
FIN FINISH(ED)
FL FLOOR
FLG FLANGE
FS FAR SIDE
FTG FOOTING
F
GA GAUGE
GALV GALVANIZED
GLB GLUE-LAMINATED BEAM
GR GRADE
G
HC HOLLOW CORE
HEX HEXIGONAL
HGT HEIGHT
HORIZ HORIZONTAL
HPT HIGH POINT
HR HANDRAIL
HSS HOLLOW STRUCTURAL
SECTION
H
ID INSIDE DIAMETER
IF INSIDE FACE
INFO INFORMATION
INS INSULATION
IT INVERTED TEE
I
JBE JOIST BEARING ELEVATION
JST JOIST
JT JOINT
J k KIP
KCJ KEYED CONTROL JOINT
KO KNOCK OUT
K
L ANGLE
LB POUND
LIN LINEAR
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LOC LOCAT(E) (ION)
LONG LONGITUDINAL(LY)
LPT LOW POINT
LTL LINTEL
LW LIGHTWEIGHT
LWC LIGHTWEIGHT CONCRETE
L
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NS NEAR SIDE
NSG NON-SHRINK GROUT
NTS NOT TO SCALE
NW NORMAL WEIGHT
N
O/C ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OH OVERHEAD
OPG OPENING
OPP OPPOSITE
O
PAR PARALLEL
PC PRECAST
PJP PARTIAL JOINT
PENETRATION
PL PLATE
PLF POUNDS PER LINEAL FOOT
PLWD PLYWOOD
PNL PANEL
PNT PAINT
PROJ PROJECT(ION) (OR)
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POST TENSION(ED) (ING)
PVC POLY-VINYL CHLORIDE
P
R RISER
RAD RADIUS
RCP REINFORCED CONCRETE PIPE
RD ROOF DRAIN
REBAR REINFORCING BAR
REF REFER(ENCE)
REINF REINFORC(E) (ED) (ING)
(EMENT)
REM REMOVABLE
REQD REQUIRED
RF ROOF
RO ROUGH OPENING
R
S S SHAPE
SC SOLID CORE
SCHED SCHEDULE
SF SQUARE FOOT
SIM SIMILAR
SL SNOW LOAD
SLV SLEEVE
SOG SLAB ON GRADE
SPEC(S) SPECIFICATION(S)
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STIF STIFFENER
STL STEEL
STRUC STRUCTUR(E) (AL)
SYM SYMMETR(Y) (ICAL)
S
T&B TOP AND BOTTOM
TBE TOP OF BEAM ELEVATION
TCE TOP OF PILE CAP (DRILLED
PIER CAP) ELEVATION
TDE TOP OF DECK ELEVATION
TEMP TEMPERATURE/TEMPORARY
TFE TOP OF FOOTING ELEVATION
TJE TOP OF JOIST ELEVATION
TLE TOP OF LEDGE ELEVATION
TME TOP OF MASNORY ELEVATION
TPE TOP OF PIER ELEVATION
TRANS TRANSVERSE
TSE TOP OF SLAB ELEVATION
TWE TOP OF WALL ELEVATION
TYP TYPICAL
T
UNO UNLESS NOTED OTHERWISE
UON UNLESS OTHERWISE NOTED
U
VAR VARIES
VERT VERTICAL
VIF VERIFY IN FIELD
VR VAPOR RETARDER
V
W WIDE FLANGE SHAPE
W/ WITH
W/O WITHOUT
WD WOOD
WL WIND LOAD
WPT WORK(ING) POINT
WS WATER STOP
WT WEIGHT/STRUCTURAL TEE
WWF WELDED WIRE FABRIC
WWM WELDED WIRE MESH
W
XP(D) EXPOSE(D)
X
℄ CENTERLINE
∠ ANGLE
@ AT
° DEGREE
Ø DIAMETER
/ PER
⏊ PERPINDICULAR
# POUND
SPECIAL SYMOBLS
Q QUANTITY
Q
CONCRETE: - SPEC 03 3000
1. CONTRACTOR SHALL TAKE NECESSARY PRECAUTIONS TO PROTECT EXISTING SOILS FROM
FREEZING OR REMOVE THEM PRIOR TO CONSTRUCTION.
2. CONCRETE SHALL NOT BE CAST AGAINST FROZEN SOILS. FROZEN SOILS SHALL BE
REMOVED PRIOR TO CASTING FOOTINGS. REPLACE FROZEN SOILS WITH COMPACTED
ENGINEER FILL.
3. INSULATED PROTECTIVE BLANKETS OR OTHER SUPPLEMENTAL HEAT SHALL BE USED TO
PROVIDE SUFFICIENT PROTECTION TO MAINTAIN DESIGNED CURING TEMPERATURES.
CONCRETE THAT FREEZES OR CRACKS DUE TO FREEZING SHALL BE REPLACED BY THE
CONTRACTOR WITH NO EXPENSE TO THE OWNER.
4. PROVIDE A MINIMUM 6" THICK DRAINAGE COURSE BELOW ALL INTERIOR FLOOR SLABS ON
GRADE UNLESS NOTED OTHERWISE ON PLANS OR SPECIFICATIONS (DRAINAGE COURSE
SHALL BE ASTM C33 FINE AGGREGATE OR SIZE #8 COARSE AGGREGATE. BETWEEN
DRAINAGE COURSE AND FINAL GRADE
5. CONCRETE FOOTINGS, WALLS, AND OTHER CONCRETE COMPONENTS SHALL BE
PROTECTED FROM FREEZING FOR A MINIMUM OF 7 DAYS CURING TIME AS FOLLOWS:
REQUIRED CONCRETE TEMPERATURES
AIR TEMPERATURE
SECTION SIZE, MINIMUM DIMENSION
< 12" 12"-36"
MINIMUM CONCRETE TEMPERATURE AS PLACED AND MAINTAINED
55° F 50° F
MINIMUM CONCRETE TEMPERATURE AS MIXED FOR INDICATED WEATHER
ABOVE 30° F 60° F 55° F
0° F TO 30° F 65° F 60° F
BELOW 0° F 70° F 65° F
CONCRETE REINFORCING: - SPEC 03 2000
1. ALL REINFORCING BAR LAPS SHALL BE CLASS "B" UNLESS NOTED OTHERWISE, PLUS 6" AT
NON-CONTACT SPLICES. SEE MASONRY/CONCRETE NOTES FOR BAR LAP SPLICE LENGTHS.
2. PROVIDE CONCRETE COVER AT REINFORCING PER THE FOLLOWING:
3. PLACEMENT OF STEEL REINFORCING SHALL BE IN ACCORDANCE WITH CRSI MANUAL OF
STANDARD PRACTICE. POSITION, SUPPORT AND SECURE REINFORCEMENT AGAINST
DISPLACEMENT. DO NOT DEVIATE FROM REQUIRED POSITION.
4. REINFORCEMENT SHALL BE INSPECTED BY THE SPECIAL INSPECTION AGENCY ACCORDING TO
THE SPECIAL INSPECTIONS AND TESTING SCHEDULE. CONTRACTOR SHALL NOTIFY SPECIAL
INSPECTION AGENCY 24 HOURS PRIOR TO REQUESTED INSPECTION.
5. DO NOT WELD REINFORCING UNLESS SPECIFICALLY SHOWN ON PLANS OR WITH WRITTEN
PERMISSION FROM ENGINEER OF RECORD.
CONCRETE COVER AT STEEL REINFORCING
REINFORCING LOCATION
CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH
CONCRETE COVER AT STEEL REINFORCING
CONCRETE COVER AT STEEL REINFORCING
CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND:
SLABS, WALLS OR JOISTS
#14 AND #18 BARS
#11 BARS AND SMALLER
MINIMUM COVER
3"
2"
1 1/2"
1 1/2" 3/4"
CAST-IN-PLACE CONCRETE: - SPEC 03 3000
1. CONCRETE SHALL BE REDI-MIXED PRODUCT (PLANT MIXED) ACCORDING TO APPROVED
CONCRETE MIX DESIGN SUBMITTALS. CONTRACTOR SHALL PROVIDE (6) COPIES OF CONCRETE
MIX DESIGN SUBMITTAL TO ENGINEER OF RECORD. CONCRETE PLACEMENT SHALL NOT
COMMENCE WITHOUT APPROVED CONCRETE MIX DESIGN SUBMITTALS. CONCRETE SHALL
NOT BE MIXED ON SITE EXCEPT FOR SMALL PATCHING. DO NOT ADD WATER TO REDI-MIXED
CONCRETE AT THE SITE EXCEPT TO REPLACE WATER LOST DURING TRANSPORTATION OF THE
CONCRETE FROM THE REDI-MIX PLANT TO THE SITE.
2. CONCRETE MIX DESIGN SHALL BE PREPARED WITH ONE OF THE FOLLOWING TWO OPTIONS:
A. CONCRETE REDI-MIX PLANT SHALL PROVIDE A HISTORY FOR EACH MIX DESIGN. THE
HISTORY SHALL SHOW TESTED CONCRETE COMPRESSIVE STRENGTH AT 28 DAYS FOR A
MINIMUM OF 30 CONSECUTIVE TESTS OR TWO GROUPS OF CONSECUTIVE TESTS
TOTALING AT LEAST 30 TESTS.
B. AN INDEPENDENT LABORATORY SHALL PREPARE EACH MIX DESIGN. THE MIX DESIGN
SUBMITTAL SHALL BE SIGNED AND SEALED BY A REGISTERED PROFESSIONAL ENGINEER.
3. THE COST TO PREPARE THE MIX DESIGN SUBMITTAL AND ANY ASSOCIATED COSTS FOR
TESTING TO PROVIDE A HISTORY SHALL BE PAID BY THE CONTRACTOR.
4. CONCRETE CURING ACCELERATORS SUCH AS CALCIUM CHLORIDE ARE NOT ALLOWED
WITHOUT WRITTEN APPROVAL FROM THE ENGINEER OF RECORD.
5. FOOTING STEPS SHALL BE GENERALLY LOCATED WHERE INDICATED ON THE FOOTING AND
FOUNDATION PLAN.
6. ALL CONTINUOUS FOOTINGS SHALL BE CENTERED BELOW WALLS UNLESS OTHERWISE NOTED
ON THE PLANS.
7. ALL SPREAD FOOTINGS SHALL BE CENTERED BELOW WALLS/PIERS/COLUMNS UNLESS
OTHERWISE NOTED ON THE PLANS.
8. PROVIDE A ROUGH SURFACE AT THE TOP OF ALL FOOTINGS.
9. DOWEL VERTICAL WALL REINFORCING TO FOOTING OR THICKENED SLAB WITH BARS OF THE
SAME SIZE AND SPACING AS THE VERTICAL WALL REINFORCING UNLESS OTHERWISE NOTED.
PROVIDE A STANDARD HOOK AT THE BOTTOM OF THE DOWEL AND EMBED INTO THE
FOOTING. PROVIDE A CLASS "B" LAB WITH THE WALL VERTICAL REINFORCING.
10. PERIMETER FOUNDATIONS WALL CONSTRUCTION JOINTS SHALL BE SPACED AT NOT MORE
THAN 50 FEET ON CENTER.
11. VERIFY WITH ARCHITECT ALL FLOOR SLAB DEPRESSIONS AND DETAILS RELATED TO
ARCHITECTURAL FINISHES. VERIFY WITH MECHANICAL DRAWINGS ALL HOUSEKEEPING PAD
LOCATIONS AND SIZES. FLOOR SLAB DEPRESSIONS AND MECHANICAL HOUSEKEEPING PADS
ARE NOT TYPICALLY SHOWN ON THE STRUCTURAL DRAWINGS.
12. PROVIDE KEYED CONSTRUCTION JOINTS (kcj) AT CONCRETE SLAB ON GRADE FLOORS AT
LOCATIONS SHOWN ON ALL PLANS. JOINTS SHALL BE DOWELED TOGETHER USING SMOOTH
STEEL DOWEL BARS INSERTED INTO PLASTIC SLEEVES (GREENSTREAK SPEED DOWELS OR
EQUAL) AS SHOWN ON THE KCJ DETAIL.
13. PROVIDE SAW CUT CONTROL JOINTS (CJ) AT CONCRETE SLAB ON GRADE FLOORS AT
LOCATIONS SHOWN ON PLANS WITHIN 18 HOURS OF CONCRETE PLACEMENT.
14. AT DROPPED SLABS ON COMPACTED SAND BASE, MAINTAIN CONCRETE THICKNESS AND
WWF REINFORCING. LIMITS OF DROPPED AND DEPRESSED FLOOR AREAS TO BE LOCATED
FROM ARCHITECTURAL PLANS.
15. PROVIDE 3" MINIMUM CONCRETE COVER AROUND STEEL COLUMNS AND STEEL BASE PLATES
EXTENDING BELOW SLABS ON GRADE.
Drawing Title
COPYRIGHT:
CHECKED BY:
DRAWN BY:
PROJECT NO:
STATE
CITY
PROJECT DESCRIPTION
DESCRIPTION DATE
ISSUE DATES
CLIENT
MARK
All plans, specifiecations, computer files, field data, notes and other documents and instruments prepared by EAPC as instruments of service shall remain the property of EAPC. EAPC shall retain all common lay, statutory and other reserved rights, including the copyright there to.
CD CONSTRUCTION
DOCUMENTS
2019 MAR 22
FI
LE
L O
C A
T
IO
N
P
LO
T D
A T E
D R e v it L o c a l F ile s \2
P ro je c ts
\2
-S
T R
U C
T r-
E A
P C jo n .e n g lu n d e a p c .n e t.
rv t
/9
/2
:1 :0
A
M
S001
20185390
JCE
TJ
MINNESOTA
GRAND RAPIDS
INFRASTRUCTURE
RENOVATION
GENERAL STRUCTURAL
NOTES
TELE FAX
www.eapc.net
Grand Forks ND Fargo ND Bismarck ND
Williston ND Minot ND Norwich VT
Bemidji MN Buenos Aires ARG
222 Third Street NW, Bemidji MN 56601
Sioux Falls SD
St. Paul MN Fort Collins Co Phoenix AZ
218.751.0151 218.751.0170
50505
Professional Engineer under the laws of the supervision and that I am a duly licensed report was prepared by me or under my direct I hereby certify that this plan, specification, or
Signature:
Print Name:
State of Minnesota.
Date: License #:
Timothy J. Gustafson
22 MAR 2019
A B S201
S201
/4
8' - 2 1/2"
A B S201
S201
HSS3X3X1/4
H S
S
X
X
/4
HSS3X3X1/4
H S
S
X
X
/4
/4
8' - 2 1/2"
FIRST FLOOR
100' - 0"
SECOND FLOOR
112' - 0"
TOP OF FRAMING
112' - 0"
A B
E Q
E Q
E Q
E Q
L2-1/2X2-1/2X1/4
L2-1/2X2-1/2X1/4
L2-1/2X2-1/2X1/4
L2-1/2X2-1/2X1/4
HSS3X3X1/4
H S
S
X
X
/4
H S
S
X
X
/4
FIRST FLOOR
100' - 0"
SECOND FLOOR
112' - 0"
TOP OF FRAMING
112' - 0"
L2 -1
/2 X2-1
/2 X1/4
L2-1/2X2-1/2X1/4
L2 -1
/2 X2
-1 /2
X1 /4
L2-1/2X2-1/2X1/4
HSS3X3X1/4
H S
S
X
X
/4
H S
S
X
X
/4
FIRST FLOOR
100' - 0"
L2-1/2X2-1/2X1/4
EXISTING CONCRETE
1/4
PL 3/8"x7 1/2"x7 1/2"
(4) 1/2"x4" ANCHORS W/
SIMPSON SET EPOXY
1/4
H S
S
X
X
/4
L2-1/2X2-1/2X1/4
L2-1/2X2-1/2X1/4
1/4
SECOND FLOOR
112' - 0"
TOP OF FRAMING
112' - 0"
1/4
1/4
1/4
L2-1/2X2-1/2X1/4
HSS3X3X1/4
H S
S
X
X
/4 ANGLE 2 1/2x 2 1/2 x 1/4
Drawing Title
COPYRIGHT:
CHECKED BY:
DRAWN BY:
PROJECT NO:
STATE
CITY
PROJECT DESCRIPTION
DESCRIPTION DATE
ISSUE DATES
CLIENT
MARK
All plans, specifiecations, computer files, field data, notes and other documents and instruments prepared by EAPC as instruments of service shall remain the property of EAPC. EAPC shall retain all common lay, statutory and other reserved rights, including the copyright there to.
CD CONSTRUCTION
DOCUMENTS
2019 MAR 22
FI
LE
L O
C A
T
IO
N
P
LO
T D
A T E
D R e v it L o c a l F ile s \2
P ro je c ts
\2
-S
T R
U C
T r-
E A
P C jo n .e n g lu n d e a p c .n e t.
rv t
/9
/2
:1 :0
A
M
S201
20185390
JCE
TJ
MINNESOTA
GRAND RAPIDS
INFRASTRUCTURE
RENOVATION
TOWER FRAMING
TELE FAX
www.eapc.net
Grand Forks ND Fargo ND Bismarck ND
Williston ND Minot ND Norwich VT
Bemidji MN Buenos Aires ARG
222 Third Street NW, Bemidji MN 56601
Sioux Falls SD
St. Paul MN Fort Collins Co Phoenix AZ
218.751.0151 218.751.0170
1/2" = 1'-0"S201
1 First Floor Slab Plan
1/2" = 1'-0"S201
2 Second Floor Framing Plan
1/2" = 1'-0"S201
3 Elevation 1 - a 1/2" = 1'-0"S201
4 Elevation 2 - a
1 1/2" = 1'-0"S201
5 Section 1 - Callout 1
1 1/2" = 1'-0"S201
6 Section 1 - Callout 2
1 1/2" = 1'-0"S201
7 Section 1 - Callout 3
50505
Professional Engineer under the laws of the supervision and that I am a duly licensed report was prepared by me or under my direct I hereby certify that this plan, specification, or
Signature:
Print Name:
State of Minnesota.
Date: License #:
Timothy J. Gustafson
22 MAR 2019
ABBREVIATIONS
CEILING GRILLECG
CONVECTOR
CHILLED WATER SUPPLY
CABINET HEATER
CLEANOUT
CEILING
CONTINUATION
DIAMETER
DRY BULB
DOWN
DRAWING
DRAIN
CHECK VALVE
COOLING TOWER
DIRECT EXPANSION
CEILING REGISTER
CONDENSATE PUMP OR CIRCULATING PUMP
COLD WATER & CONDENSER WATER
CHILLED WATER RETURN
DX
DIA
DN
DB
DR
DWG
CW
CV
CT
CWS
CONV
CR
CUH
CP
CONT
CO
CLG
CWR
ABOVE FINISHED FLOOR
AIR COOLED CONDENSING UNIT
ACCESS DOOR OR AREA DRAIN
AIR HANDLING UNIT
AIR CONDITIONING UNIT
AQUEOUS FILM FORMING FOAM
COOLING COIL
CONVECTOR
BOTTOM OF PIPE
CUBIC FEET PER MINUTE
CEILING DIFFUSER OR CONDENSATE DRAIN
BRITISH THERMAL UNIT
BRAKE HORSEPOWER
BOTTOM OF THE BEAM
BALANCING VALVE
CEILING EXHAUST FAN
BACK DRAFT DAMPER
BTU
CFM
CC
CD
C
BOP
BV
BOB
CEF
AHU
ACCU
AFF
AD
AC
AFFF
BHP
BDD
LEGEND
ABBREVIATIONS
MAXIMUMMAX
THOUSAND BTU PER HOUR
MOTOR CONTROL CENTER
NEW TO EXISTING CONNECTION
MOTOR OPERATED DAMPER
OPPOSED BLADE DAMPER
OUTSIDE DIMENSION
OVERFLOW STORM PIPING
OUTSIDE SCREW & YOKE GATE VALVE
OA
OBD
OST
OS&Y
OD
NTS
NO
NFA
NIC
OUTSIDE AIR
NET FREE AREA
NORMALLY OPEN
NOT TO SCALE
NOT IN CONTRACT
MUA
N/E
MOD
NC
MS
MBH
MCC
MIN
MH
NORMALLY CLOSED
MAKE UP AIR UNIT
MOP SINK
MANHOLE
MINIMUM
HEATING AND VENTILATING UNIT
HOT WATER CIRCULATION
LEAVING AIR TEMPERATURE
LEAVING WATER TEMPERATURE
MIXED AIR TEMPERATURE
LINEAR SLOT DIFFUSER (CEILING, WALL, SILL, & FLOOR)
MAT
LWT
LSD
LVR
LAT
LBS
LDR
L
JP
LOUVER
POUNDS
LAVATORY
JOCKEY PUMP
LEADER
HWC
IN
JS
ID
HX
HWS & HWR
HVU
HP
HEAT EXCHANGER
INSIDE DIMENSION
JANITOR'S SINK
INCHES
HORSE POWER
HOT WATER SUPPLY AND RETURN
CHECK VALVE, FLOW DIRECTION
FLOOR CLEANOUT/GRADE CLEANOUT
GLOBE VALVE
GATE VALVE
MIXING VALVE
METER
MANUAL AIR VENT
GAS PRESSURE REGULATOR
M
DIRT POCKET
FLOW MEASURING STATION
GAS COCK VALVE
ECCENTRIC REDUCER (E.R.)
CONCENTRIC REDUCER
F
PC
ST
LPS
LPR
MPS
HPS
HWS
HWR
AUTOMATIC 2-WAY CONTROL VALVE
ARROW INDICATES DIRECTION OF FLOW
CAPPED PIPE WITH SHUT-OFF VALVE
AUTOMATIC FLOW CONTROL VALVE
AUTOMATIC 3-WAY CONTROL VALVE
BACK FLOW PREVENTER-RPZ
BALL VALVE
BALANCING VALVE
BOTTOM PIPE CONNECTION
ANGLE RELIEF VALVE
AUTOMATIC AIR VENT
A
CW
FOV
HPC
G
HPR
FOR
FOS
CHWR
CWR
CHWS
A
CD
SPACING
(MAXIMUM)
26 24(.020) A & BUP THRU 18"
THERMOSTAT WITH ZONE OR
EQUIPMENT DESIGNATION
DUCT SMOKE DETECTOR SUPPLIED BY ELECTRICAL
TRADE, INSTALLED BY MECHANICAL TRADE.
H
T
S
HUMIDISTAT
FLOW SWITCH
19" THRU 24"
25" THRU 36"
37" THRU 54"
55" THRU 80"
81" THRU 96"
OVER 96"
22(.025)
22(.025)
20(.032)
18(.040)
16(.051)
16(.051)18
H OR J
E OR I
E OR I
F OR G
H OR J
C
CEILING DIFFUSER
PARTITION OR WALL (SIZE)
DUCT MOUNTED HEATING COIL, WITH DUCT
ACCESS DOOR UPSTREAM OF HEATING COIL.
RETURN REGISTER OR GRILLE
TRANSFER GRILLES ON BOTH SIDES OF
SUPPLY REGISTER WITH AIR OUTLET
TERMINAL UNIT WITH HEATING COIL
SUPPLY DUCT UP
DEVICE DESIGNATION (100 CFM)
ROUND DUCT, UP
SUPPLY DUCT DOWN
RETURN OR EXHAUST DUCT UP
RETURN OR EXHAUST DUCT DOWN
RETURN OR EXHAUST REGISTER OR GRILLE
WITH AIR INLET DEVICE DESIGNATION (100 CFM)
ROUND DUCT, DOWN
RECTANGULAR
SHEET / CONSTRUCTION NOTE NUMBER
REVISION NUMBER
POINT OF CONNECTION (NEW TO EXISTING)
HATCH INDICATES ITEM(S) TO BE REMOVED
INTERNALLY LINED DUCTWORK
SECTION DESIGNATION
DETAIL DESIGNATION
DETAIL NUMBER
DRAWING NUMBER
DRAWING NUMBER
SECTION NUMBER
SQUARE FEET
RECTANGULAR
RECTANGULAR
RECTANGULAR
FLOOR DRAIN, AREA DRAIN
WATER CLOSET
URINAL
SINK
ELECTRIC WATER COOLER
LAVATORY
MOP BASIN
SANITARY WASTE, UNDERGROUND
SANITARY WASTE, ABOVE GRADE
(AW - ACID WASTE UNDERGROUND)
(AW - ACID WASTE ABOVE GRADE)
DOMESTIC HOT WATER CIRCULATION
SYMBOLS
TRG 12X12
R-1
S-1
ACCESS
AREA
SLOT DIFFUSER
H-1/8"
DUCT
DIMENSION
H
GAUGES
STEEL/ALUMINUM
(J)
(I)
TYPE
JOINTS
ANGLE REINFORCED
STANDING SEAM
AIR FLOW
(H)
H
H
(G)
AIR FLOW
STANDING SEAM
ANGLE SLIP
AIR FLOW
H
(F)
H
(E)
REINFORCED
BAR SLIP (CLEAT)
ALTERNATE BAR SLIP
(STANDARD "S" SLIP)
(C)
AIR FLOW
H
AIR FLOW
AIR FLOW
(B)
BAR SLIP
PLAIN "S" SLIP
HEMMED "S" SLIP
8'-0"
1 1/2"X1/8"L
1 1/2"X1/8"L
2'-0" 2"X1/4"L
4'-0"
3'-0"
2'-6"
5'-0"
5'-0"
1 1/8"
1"
H" DIMENSION
JOINT
(MINIMUM)
BACK FLOW PREVENTER ASSEMBLY
FIRE PROTECTION
ALARM CHECK VALVE W/ ALL RELATED APPURTENANCES
FIRE DEPT. HOSE VALVE W/ CAP & CHAIN
SPRINKLER INSPECTOR TEST STATION
EXTENDED COVERAGE SIDEWALL SPRINKLER HEAD
REDUCED PRESSURE BACK FLOW PREVENTER ASSEMBLY
PRE-ACTION VALVE W/ ALL RELATED APPURTENANCES
SPRINKLER FLOOR CONTROL VALVE ASSEMBLY
FIRE DEPARTMENT CONNECTION WALL MOUNTED
H= HEIGHT REFERRED TO IN DIMENSIONS
DRY PIPE VALVE W/ ALL RELATED APPURTENANCES
DUCT CONSTRUCTION STANDARDS
LEGEND
LEGEND
SLOPING RISE (R) OR DROP (D) IN DUCTWORK
DUCT SIZE (CLEAR INSIDE DIMENSION)
FIRST FIGURE INDICATES PLAN SIZE
DUCT ACCESS DOOR
(BDD) BACK DRAFT DAMPER
ROUND DUCT DIAMETER SIZE
VOLUME DAMPER IN DUCT (VD)
FLEXIBLE CONNECTION IN DUCT
ELBOW WITH TURNING VANES
DUCT SPLIT WITH SPLIT SIZE
(FD) FIRE DAMPER, (SD) SMOKE DAMPER,
(F/S) COMBINATION FIRE SMOKE DAMPER,
BRANCH TAKEOFF WITH VOLUME DAMPER
STORM DRAIN PIPING (BELOW GRADE)
PUMPED CONDENSATE RETURN
STORM DRAIN PIPING (ABOVE GRADE)
VENT PIPING (AV-ACID VENT)
DOMESTIC COLD WATER
DOMESTIC HOT WATER
MEDIUM PRESSURE STEAM
HIGH PRESSURE STEAM SUPPLY
LOW PRESSURE STEAM SUPPLY
LOW PRESSURE STEAM RETURN
HEATING WATER SUPPLY
HEATING WATER RETURN
18X12
RADIUS ELBOW
CONDENSER WATER SUPPLY
HIGH PRESSURE CONDENSATE RETURN
FUEL OIL SUPPLY PIPING
FUEL OIL RETURN PIPING
FUEL OIL VENT PIPING
HIGH PRESSURE STEAM RETURN
NATURAL GAS PIPING
CHILLED WATER RETURN
CONDENSATE DRAIN OR RETURN
CONDENSER WATER RETURN
CHILLED WATER SUPPLY
COMPRESSED AIR LINE
FLEXIBLE DUCT
18∅
18X12
R
(A)
DRIVE SLIP
ROOF MANIFOLD
SIDEWALL SPRINKLER HEAD
RPBP
PAV
HOSE BIBB
FIRE HOSE VALVE
FIRE HOSE VALVE CABINET
PENDANT SPRINKLER HEAD
DOUBLE CHECK VALVE
UPRIGHT SPRINKLER HEAD
DPV
DCVA
BPA
ACV
TC-1 TERMINAL COIL - (COIL NUMBER)
IJS IN JOIST SPACE
GHWS
GLYCOL HOT WATER SUPPLY
GHWR
GLYCOL HOT WATER RETURN
GLYCOL CHILLED WATER SUPPLY
GCWS
GLYCOL CHILLED WATER RETURN
GCWR
F/S FD SDRD
P
BUTTERFLY VALVE
WALL CLEANOUT
QUANTITY IN ROOM
S-SUPPLY, R-RETURN, E-EXHAUST, T-TRANSFERNO.
CFM
ST
ZONE VALVE
MEDICAL GAS OUTLET (TYPICAL)
A
MA
MEDICAL AIR
OX
OXYGEN
VAC
VACUUM
NO
NITROUS OXIDE
WAG
WASTE ANESTHESIA GAS
MECHANICAL LEGEND
GLYCOL
HEATING COIL
GALLONS
GATE VALVE
HOSE BIBB
GALLONS PER MINUTE
HC
GLY
HB
GPM
GV
GAL
°F DEGREES FAHRENHEIT
FLOOR
FIXTURE UNIT
FEET
FURNISHED BY OTHERS
FULL LOAD AMPERES
COMBINATION FIRE AND SMOKE DAMPER
FIN TUBE RADIATION
FLEXIBLE CONNECTION
FIRE CONTROL CENTER
LOW PRESSURE NATURAL GAS
FLOW SWITCH OR FLOOR SINK
FUEL OIL PUMP OR FIRE PUMP
FUEL OIL VENT PIPING
FUEL OIL SUPPLY PIPING
FUEL OIL RETURN PIPING
FIRE DEPARTMENT CONNECTION
FIRE HOSE CABINET
FLOOR DRAIN OR FIRE DAMPER
FSD
FS
FOV
FP
FOS
FTR
G
FU
FT
FBO
FC
FCC
FD
FLR
FLA
FOR
FHC
FDC
EXHAUST AIR
EXHAUST FAN
EFFICIENCY
ELEVATOR
EXHAUST GRILLE
ELEVATION
EXPANSION TANK
EXISTING
ELECTRIC HEATING COIL
ENTERING WATER TEMPERATURE
ENTERING DRY BULB
ELECTRIC UNIT HEATER
ENTERING WET BULB
ELECTRIC CABINET HEATER
ENTERING AIR TEMPERATURE
EXHAUST RESISTER
ELECTRIC WATER HEATER
ELECTRIC WATER COOLER
EHC
ELEV
EL
EWB
EUH
EWT
ET
EXIST
ER
EA
EAT
EFF
EF
EDB
ECH
EG
EWH
EWC
WALL OPENING (SIZE)WO 12X12
WC
WH
WB
W
WET BULB
WALL HYDRANT
WATER CLOSET
WASTE
HOSE END BLOW OFF VALVE
"Y" TYPE STRAINER WITH
SD
SMOKE DAMPER OR SMOKE DETECTOR
SUPPLY FAN OR SQUARE FEET
VARIABLE FREQUENCY DRIVE
VENT THROUGH ROOF
VARIABLE AIR VOLUME TERMINAL UNIT
STATIC PRESSURE OR SUMP PUMP
STORM PIPING OR SOUND TRAP (SOUND ATTENUATOR)
VAR
VFD
VTR
VAV
VD
VTR
UR
UH
TYP
VARIABLE
VOLUME DAMPER
TYPICAL
VENT THRU ROOF
UNIT HEATER
URINAL
SPKR
ST
TS
TOP
SS
SENS
SP
SF
SE
SPRINKLER
TOP OF PIPE
SERVICE SINK
TAMPER SWITCH
SENSIBLE
SEWAGE EJECTOR
POUNDS PER SQUARE INCH
POST INDICATING VALVE
PRESSURE DROP OR PUMP DISCHARGE
PRESSURE REDUCING VALVE OR POWER ROOF VENT
PLATE AND FRAME HEAT EXCHANGER
POUNDS PER SQUARE INCH (GAUGE)
REVOLUTIONS PER MINUTE
PSIG
SAN
SA
RTU
S
RPM
RD
RAF
RA
ROOF TOP UNIT
SANITARY
SUPPLY AIR
SINK
RETURN AIR
ROOF DRAIN
RETURN AIR FAN
PG
PHC
PSI
PRV
PIV
PFHX
P/FT
PD
P
PRESSURE GAUGE
PREHEAT COIL
PITCH PER FOOT
PUMP
SLEEVE
TEMPERATURE-PRESSURE TEST FITTING
VALVE WITH TAMPER SWITCH
THERMOMETER WELL
UNION
VACUUM BREAKER
TOP PIPE CONNECTION
"Y" TYPE STRAINER
WATER FLOW SWITCH
STEAM TRAP
SOLENOID VALVE
THERMOMETER
TEMPERATURE SENSOR
T
M2.1
M3.1
OS&Y (OUTSIDE SCREW & YOKE) VALVE
PIPING FLEXIBLE CONNECTION
PRESSURE REDUCING VALVE (PRV)
PRESSURE GAUGE AND GAUGE COCK
PITCH PIPE DOWN IN DIRECTION OF FLOW
PUMP
SHOCK ABSORBER
PIPE GUIDE
PIPE ANCHOR
PIPE DOWN
PIPE UP
PIPE EXPANSION JOINT
FD
WC
S
U
L
MB
EWC
HOT WATER
HW
MP01 MECHANICAL SYMBOLS & LEGEND SHEET
P100 UNDERGROUND PLUMBING DEMOLITION PLAN
P101 FIRST FLOOR PLUMBING DEMOLITION PLAN
P200 UNDERGROUND PLUMBING PLAN
P201 FIRST FLOOR PLUMBING PLAN, SCHEDULE, DETAIL & RISER
M101 FIRST FLOOR MECHANICAL DEMOLITION PLAN
M301 FIRST FLOOR MECHANICAL PLAN, ROOF PLAN & SECTIONS
M601 MECHANICAL SECTIONS & DETAILS
M801 MECHANICAL SCHEDULES
MECHANICAL SHEET INDEX
S-1
P l o t
D a t e M a r
F i l e
L o c a t i o n W
G
R N
D R
P D
S
U
S D
A
I n f r a s t r u c t u r e
R e n o v D r a w i n g s M
P d w g
MECHANICAL
SYMBOLS & LEGEND
SHEET
DRAWING TITLE
CHECKED BY:
DRAWN BY:
MP01
JS
JV
CD CONSTRUCTION
DOCUMENTS
2019 MAR 22
DESCRIPTION DATE
INFRASTRUCTURE
RENOVATION
MARK
CLIENT
PROJECT DESCRIPTION
CITY
STATE
ISSUE DATES
PROJECT NO: 20185390
GRAND RAPIDS
MINNESOTA
TELE FAX
Grand Forks ND Williston ND Bemidji MN
Fargo ND Minot ND Buenos Aires ARG
Bismarck ND Norwich VT
222 Third Street NW, Bemidji, MN 56601
218.751.0151 218.751.0170
Sioux Falls SD St. Paul MN Fort Collins CO Phoenix AZ
TYLER COULOMBE
License #:
I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed Professional Engineer under the laws of the
Print Name:
Signature:
Date:
State of Minnesota.
5616503/22/2019
AutoCAD SHX Text
FU_COLD
AutoCAD SHX Text
FU_HOT
AutoCAD SHX Text
FU_WASTE
AutoCAD SHX Text
FU_TOTAL
AutoCAD SHX Text
FIXT_CODE
AutoCAD SHX Text
FU_COLD
AutoCAD SHX Text
FU_HOT
AutoCAD SHX Text
FU_WASTE
AutoCAD SHX Text
FU_TOTAL
AutoCAD SHX Text
FIXT_CODE
AutoCAD SHX Text
FU_COLD
AutoCAD SHX Text
FU_HOT
AutoCAD SHX Text
FU_WASTE
AutoCAD SHX Text
FU_TOTAL
AutoCAD SHX Text
FIXT_CODE
AutoCAD SHX Text
FU_COLD
AutoCAD SHX Text
FU_HOT
AutoCAD SHX Text
FU_WASTE
AutoCAD SHX Text
FU_TOTAL
AutoCAD SHX Text
FIXT_CODE
AutoCAD SHX Text
FU_TOTAL
AutoCAD SHX Text
FU_WASTE
AutoCAD SHX Text
FU_HOT
AutoCAD SHX Text
FU_COLD
AutoCAD SHX Text
FIXT_CODE
AutoCAD SHX Text
FU_TOTAL
AutoCAD SHX Text
FU_WASTE
AutoCAD SHX Text
FU_HOT
AutoCAD SHX Text
FU_COLD
AutoCAD SHX Text
FIXT_CODE
AutoCAD SHX Text
FU_COLD
AutoCAD SHX Text
FU_HOT
AutoCAD SHX Text
FU_WASTE
AutoCAD SHX Text
FU_TOTAL
FIXT_CODE
DEMOLITION NOTES:
DISCONNECT, REMOVE & DISPOSE OF EXISTING SINK & ASSOCIATED WASTE & VENT
PIPE. CAP WASTE PIPE AT MAIN. FIELD VERIFY EXACT SIZE & LOCATION.
DISCONNECT, REMOVE & DISPOSE OF EXISTING SINK. CAP WASTE PIPE AT WALL AND
ABANDON IN PLACE. FIELD VERIFY EXACT SIZE & LOCATION.
FLOOR CUTTING SHALL BE BY THE G.C. FIELD VERIFY EXACT LOCATION REQUIRED FOR
REMOVAL OF EXISTING PIPING & INSTALLATION OF UNDERGROUND PIPING,
COORDINATE CUTTING & PATCHING WITH G.C. PLUMBING CONTRACTOR SHALL
EXCAVATE AS REQUIRED FOR INSTALLATION OF NEW SANITARY WASTE PIPING THIS
LOCATION. PLUMBING CONTRACTOR SHALL BACKFILL & COMPACT AS REQUIRED TO
MATCH EXISTING.
P100
UNDERGROUND PLUMBING DEMOLITION PLAN
1/4" = 1'-0"
N N
KEY PLAN
N.T.S.
G.C. FLOOR CUTTING FOR FREEZER
INSTALLATION. PLUMBING
CONTRACTOR TO COORDINATE
ALL UNDERGROUND PLUMBING
WORK IN THIS LOCATION WITH
G.C. & FREEZER INSTALLATION.
P l o t
D a t e M a r
F i l e
L o c a t i o n W
G
R N
D R
P D
S
U
S D
A
I n f r a s t r u c t u r e
R e n o v D r a w i n g s P d w g
UNDERGROUND
PLUMBING
DEMOLITION PLAN
DRAWING TITLE
CHECKED BY:
DRAWN BY:
P100
JS
JV
CD CONSTRUCTION
DOCUMENTS
2019 MAR 22
DESCRIPTION DATE
INFRASTRUCTURE
RENOVATION
MARK
CLIENT
PROJECT DESCRIPTION
CITY
STATE
ISSUE DATES
PROJECT NO: 20185390
GRAND RAPIDS
MINNESOTA
TELE FAX
Grand Forks ND Williston ND Bemidji MN
Fargo ND Minot ND Buenos Aires ARG
Bismarck ND Norwich VT
222 Third Street NW, Bemidji, MN 56601
218.751.0151 218.751.0170
Sioux Falls SD St. Paul MN Fort Collins CO Phoenix AZ
TYLER COULOMBE
License #:
I hereby certify that this plan, specification, or report was prepared by me or under my direct supervision and that I am a duly licensed Professional Engineer under the laws of the
Print Name:
Signature:
Date:
State of Minnesota.
5616503/22/2019
AutoCAD SHX Text
FREEZER
rsindt
DEMOLITION NOTES:
DISCONNECT, REMOVE & DISPOSE OF EXISTING DOMESTIC HOT & COLD WATER PIPE
AS INDICATED BY HATCH. FIELD VERIFY EXACT SIZE & LOCATION.
DISCONNECT, REMOVE & DISPOSE OF EXISTING SINK & ASSOCIATED DOMESTIC WATER,
WASTE & VENT…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.