d_Siding_Upgrade_Construction_Requisition_Dwgs.pdf
PDF 15 MB Posted
- Attached to
- Facility Infrastructure Inprovements Federal contract opportunity
- Solicitation number
- 1263PX19Q0065
About this file
The drawings to up grade the siding at NRS Grand Rapids.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| E201_Ammended_07302019.pdf | ||
| M101_Ammended_07292019.pdf | ||
| Amendment-003-0065.pdf | ||
| A501_Ammended_07292019.pdf | ||
| dwg-07292019.zip | ZIP file | |
| GR_Sign_in.pdf | ||
| SF-30_GR-001.pdf | ||
| SF-30-001.pdf | ||
| ure_Renovations_Construction_Requisition_Specs.pdf | ||
| RFP-Grand_Rapids_Infrastructure_Improvements.doc | DOC document | |
| ture_Renovations_Construction_Requisition_Dwgs.pdf | ||
| Siding_Upgrade_Construction_Requisition_Specs.pdf | ||
| ure_Renovations_Construction_Requisition_Specs.pdf | ||
| Siding_Upgrade_Construction_Requisition_Specs.pdf | ||
| d_Siding_Upgrade_Construction_Requisition_Dwgs.pdf | ||
| ure_Renovations_Construction_Requisition_Specs.pdf | ||
| ure_Renovations_Construction_Requisition_Specs.pdf | ||
| RFP-Grand_Rapids_Infrastructure_Improvements.doc | DOC document |
Show all 18
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DETAIL REFERENCE
Detail Number
Sheet Number
EXTERIOR ELEVATION
Exterior Elevation Number
Sheet Number
ROOM NAME/
ROOM NUMBER
SPECIFIC ELEVATION NOTE
SPECIFIC PLAN NOTE
REVISION
(Cloud Around Revision)
ROOM NAME
RM ##
SPECIFIC DEMOLITION NOTE#
A501
WALL SECTION CALLOUT
A801
DETAIL CALLOUT
A801
DETAIL CALLOUT
SHEET NAME
SHEET NO.
DATE
DRAWING SET
ARCHITECTURE
ENGINEERING
INTERIOR DESIGN
STRANG, INC.
6411 MINERAL POINT ROAD
MADISON, WI 53705-4395
ARCHITECTURAL
STRANG, INC.
DESIGN TEAM PROJECT IMAGE
SHEET INDEXSTAMPS
SITE LOCATION MAP
SYMBOL LEGEND
ELECTRICAL NOTES
TITLE SHEET
T001
12/21/2016
CD
1831 E. US HIGHWAY 169
GRAND RAPIDS, MN 55744 PROJECT NO. : 2012012.04
GENERAL
T001 TITLE SHEET
ARCHITECTURAL
A101 DEMOLITION FIRST FLOOR PLAN
A102 DEMOLITION ROOF PLAN
A141 DEMOLITION EXTERIOR ELEVATIONS
A201 FIRST FLOOR PLAN
A202 ROOF PLAN
A401 EXTERIOR ELEVATIONS
A501 WALL SECTIONS
A801 EXTERIOR DETAILS
A802 EXTERIOR DETAILS
A803 EXTERIOR DETAILS
A804 EXTERIOR DETAILS
A805 EXTERIOR DETAILS
A806 EXTERIOR DETAILS
- CONSTRUCTION DOCUMENT PACKAGE
SITE
USDA FOREST SERVICE
NORTHERN RESEARCH STATION
FORESTRY SCIENCES LABORATORY GRAND RAPIDS
ROOF & SIDING UPGRADE
FORESTRY SCIENCES
LABORATORY
GRAND RAPIDS
ARCHITECTURAL DESIGN
GENERAL: ELECTRICAL COMPONENTS, DEVICES AND ACCESSORIES SHALL BE LISTED AND LABELED AS DEFINED IN NFPA 70 ARTICLE 100. SUBMIT PRODUCT
DATA AND SAMPEL FOR EACH TYPE OF PRODUCT.
PRODUCTS: MANUFACTURERS SHALL BE ONE OF THE FOLLOWING: HUBBELL INCORPORATED; WIRING DEVICES-KELLEMS; LEVITON MFG. COMPANY INC.; PASS &
SEYMOUR/LEGRAND; WIRING DEVICES DIV.
RECEPTACLES: GFCI RECEPTACLES SHALL BE STRAIGHT BLADE, NON-FEED-THROUGH TYPE, HEAVY-DUTY GRADE, 5-20R DUPLEX RECEPTACLE. DESIGN UNITS FOR INSTALLATION IN A 2-3/4-INCH DEEP OUTLET BOX WITHOUT AN ADAPTER. VERIFY ASSEMBLY SIZE WITH WALL THICKNESS.
WALL PLATES: MATERIAL FOR OUTDOOR WET LOCATIONS SHALL BE CAST ALUMINUM BUBBLE TYPE COVER, AND LISTED AND LABELED FOR USE IN "WET
LOCATIONS" AND SHALL BE WEATHERPROOF TYPE WITH THE ATTACHMENT PLUG CAP INSERTED.
EXECUTION: INSTALL DEVICES AND ASSEMBLIES LEVEL, PLUMB, AND SQUARE WITH BUILDING LINES. DEVICES SHALL BE MOUNTED FLUSH, WITH LONG DIMENSION VERTICAL, AND WITH GROUNDING TERMINAL OF RECEPTACLES ON TOP. REMOVE WALL PLATES AND PROTECT DEVICES AND ASSEMBLIES DURING
SURFACE PAINTING BY OTHER CONTRACTORS.
A141
A141
A141
A141
A141
CONFERENCE
ENTRY
OFFICE/LAB
GIS
SHOP/GARAGE
STORAGE
HEADHOUSE
ARCHIVE
W O
O D
S
I D
I N
G
M E
T A
L
S
I D
I N
G
M E
T A
L
S
I D
I N
G
M E
T A
L
S
I D
I N
G
WOOD
SIDING
WOOD
SIDING
METAL SIDING
W O
O D
S
I D
I N
G
A141
A141
A141
A141
A141
A141
13 13 13
ARCHITECTURE
ENGINEERING
INTERIOR DESIGN
STRANG, INC.
6411 MINERAL POINT ROAD
MADISON, WI 53705-4395
SHEET NAME
PROJECT TITLE
DRAWING SET
DRAWN
CHECKED
DATE
PROJECT NO.
SHEET NO.
CONSTRUCTION
DOCUMENT SET
FOR
CONSTRUCTION
TC
12/21/2016
AH/TZ
1831 E. US HIGHWAY 169
GRAND RAPIDS, MN 55744
USDA FOREST
SERVICE -
NORTHERN
RESEARCH
STATION - ROOF &
SIDING UPGRADE
2012012.04
CD
DEMOLITION FIRST
FLOOR PLAN
A101
GENERAL DEMOLITION PLAN NOTES
1 MAINTAIN CONTINUOUS UTILITY SERVICE TO ALL
SPACES IN THE BUILDING. COORDINATE WITH
OWNER ANY DISRUPTIONS WHICH MAY BE
REQUIRED TO COMPLETE THE WORK.
2 PROTECT IN PLACE DURING ENTIRE
CONSTRUCTION PROCESS: DOORS, WINDOWS,
SURFACES AND ITEMS TO REMAIN.
3 COORDINATE WITH OWNER THE AVAILABILITY OF
AREAS REQUIRING DEMOLITION. SEQUENCE WORK
ACCORDINGLY AND COORDINATE W/ ALL TRADES.
4 THE CONTRACTOR SHALL PATCH, PREPARE,
REPAIR AND/OR RESTORE SURFACES SCHEDULED
TO REMAIN INTACT THAT ARE DAMAGED AS A
RESULT OF DEMOLITION WORK.
5 DEMOLITION PLANS ARE NOT NECESSARILY
INCLUSIVE OF ALL ITEMS NEEDING REMOVAL.
COORDINATE WITH ALL OTHER DRAWINGS AND
FIELD VERIFY EXISTING CONDITIONS.
6 COORDINATE DEMOLITION DIMENSIONS ON THIS
PLAN WITH NEW WORK PLANS AND EXISTING
CONDITIONS.
7 MAINTAIN ALL EXIT DOORS IN UNOBSTRUCTED
OPERABLE CONDITION WITH SAFE PASSAGEWAY
FROM BUILDING. COORDINATE WITH THE LOCAL
FIRE MARSHAL AND BUILDING INSPECTOR.
8 PROVIDE AND MAINTAIN BARRICADES, GATES, OR
OTHER MEANS OF MAINTAINING PUBLIC SAFETY AT
ALL AREAS OF CONSTRUCTION OR DEMOLITION.
9 SEE NEW WORK ELEVATIONS AND DETAILS FOR
ADDITIONAL SELECTIVE DEMOLITION WORK.
10 WORK WHICH RENDERS THE EXISTING BUILDING
NON-WEATHER TIGHT SHALL BE FITTED TO
PROVIDE WEATHER TIGHT STRUCTURE PRIOR TO
NEW WORK BEING INSTALLED.
11 ALL EXISTING PENETRATIONS AND ATTACHMENTS
INCLUDING LIGHTS AT SOFFITS AND ROOFS TO BE
MODIFIED AS NECESSARY TO ACCOMMODATE NEW
SOFFIT AND ROOF ASSEMBLY.
SPECIFIC DEMOLITION PLAN NOTES
1 DORMER ABOVE FLOOR PLAN CUT LEVEL FOR
REFERENCE.
2 DASHED LINES REPRESENT AREAS TO BE
DEMOLISHED, SEE NOTES ON PLAN FOR
ADDITIONAL INFORMATION.
3 REMOVE EXTERIOR ASSEMBLY TO EXISTING
SHEATHING OR CONCRETE MASONRY UNITS (CMU).
4 OFFICE/LAB, SHOP/GARAGE, AND HEADHOUSE
BUILDINGS ASSUMED TO HAVE LEAD WOOD SIDING,
PROVIDE LEAD SAFE DEMOLITION OF MATERIAL.
5 REMOVE WOOD SIDING.
6 REMOVE METAL SIDING.
7 REMOVE METAL SIDING AND 2" RIGID INSULATION.
8 EXISTING DOOR TO REMAIN UNLESS NOTED
OTHERWISE, TYPICAL.
9 EXISTING WINDOW TO REMAIN UNLESS NOTED
OTHERWISE, TYPICAL.
10 EXISTING OVERHEAD DOOR TO REMAIN, TYPICAL.
11 EXISTING EXPOSED CONCRETE MASONRY UNITS
(CMU) TO REMAIN.
12 REMOVE DOOR AND FRAME.
13 REMOVE WINDOW.
SCALE: 1/8" = 1'-0"
A101
FIRST FLOOR PLAN
0' 4' 8'
NORTH
REVISED 03/11/2019
REMOVE
FULLY ADHERED EPDM
REMOVE BALLASTED EPDM
FULLY ADHERED EPDM TO REMAIN
FULLY ADHERED EPDM TO REMAIN
FULLY ADHERED EPDM TO REMAIN
REMOVE BALLASTED EPDM
REMOVE BALLASTED EPDM
REMOVE BALLASTED EPDM
REMOVE BALLASTED EPDM
REMOVE BALLASTED EPDM
REMOVE
FULLY ADHERED EPDM
FULLY ADHERED EPDM TO REMAIN
ROOF SLOPE
ROOF SLOPE
ROOF SLOPE
ROOF SLOPE ROOF SLOPE
ROOF SLOPE
ROOF SLOPE
ROOF SLOPE
3 17
ARCHITECTURE
ENGINEERING
INTERIOR DESIGN
STRANG, INC.
6411 MINERAL POINT ROAD
MADISON, WI 53705-4395
SHEET NAME
PROJECT TITLE
DRAWING SET
DRAWN
CHECKED
DATE
PROJECT NO.
SHEET NO.
CONSTRUCTION
DOCUMENT SET
FOR
CONSTRUCTION
TC
12/21/2016
AH/TZ
1831 E. US HIGHWAY 169
GRAND RAPIDS, MN 55744
USDA FOREST
SERVICE -
NORTHERN
RESEARCH
STATION - ROOF &
SIDING UPGRADE
2012012.04
CD
DEMOLITION ROOF
PLAN
A102
SCALE: 1/8" = 1'-0"
A102
ROOF PLAN
0' 4' 8'
GENERAL DEMOLITION PLAN NOTES
1 MAINTAIN CONTINUOUS UTILITY SERVICE TO ALL
SPACES IN THE BUILDING. COORDINATE WITH
OWNER ANY DISRUPTIONS WHICH MAY BE
REQUIRED TO COMPLETE THE WORK.
2 PROTECT IN PLACE DURING ENTIRE
CONSTRUCTION PROCESS: DOORS, WINDOWS,
SURFACES AND ITEMS TO REMAIN.
3 COORDINATE WITH OWNER THE AVAILABILITY OF
AREAS REQUIRING DEMOLITION. SEQUENCE WORK
ACCORDINGLY AND COORDINATE W/ ALL TRADES.
4 THE CONTRACTOR SHALL PATCH, PREPARE,
REPAIR AND/OR RESTORE SURFACES SCHEDULED
TO REMAIN INTACT THAT ARE DAMAGED AS A
RESULT OF DEMOLITION WORK.
5 DEMOLITION PLANS ARE NOT NECESSARILY
INCLUSIVE OF ALL ITEMS NEEDING REMOVAL.
COORDINATE WITH ALL OTHER DRAWINGS AND
FIELD VERIFY EXISTING CONDITIONS.
6 COORDINATE DEMOLITION DIMENSIONS ON THIS
PLAN WITH NEW WORK PLANS AND EXISTING
CONDITIONS.
7 MAINTAIN ALL EXIT DOORS IN UNOBSTRUCTED
OPERABLE CONDITION WITH SAFE PASSAGEWAY
FROM BUILDING. COORDINATE WITH THE LOCAL
FIRE MARSHAL AND BUILDING INSPECTOR.
8 PROVIDE AND MAINTAIN BARRICADES, GATES, OR
OTHER MEANS OF MAINTAINING PUBLIC SAFETY AT
ALL AREAS OF CONSTRUCTION OR DEMOLITION.
9 SEE NEW WORK ELEVATIONS AND DETAILS FOR
ADDITIONAL SELECTIVE DEMOLITION WORK.
10 WORK WHICH RENDERS THE EXISTING BUILDING
NON-WEATHER TIGHT SHALL BE FITTED TO
PROVIDE WEATHER TIGHT STRUCTURE PRIOR TO
NEW WORK BEING INSTALLED.
11 ALL EXISTING PENETRATIONS AND ATTACHMENTS
INCLUDING LIGHTS AT SOFFITS AND ROOFS TO BE
MODIFIED AS NECESSARY TO ACCOMMODATE NEW
SOFFIT AND ROOF ASSEMBLY.
SPECIFIC DEMOLITION ROOF PLAN NOTES
1 BASE BID - REMOVE ROOF ASSEMBLY TO EXISTING
RIGID INSULATION. ADD-ALT: REMOVE ROOF
ASSEMBLY TO EXISTING SHEATHING, RIGID
INSULATION TO BE REMOVED.
2 REMOVE FASCIA AND RAKE TRIM FINISH, TYPICAL
AROUND BUILDING.
3 EXISTING EXHAUST HOOD CURB TO REMAIN.
4 EXISTING ROOF PENETRATION.
5 REMOVE SCUPPER.
6 EXISTING SKYLIGHT CURB TO REMAIN.
7 REMOVE DOWNSPOUT.
8 EXISTING OVERHANG.
9 REMOVE SOFFIT VENT.
10 EXISTING AIR HANDLING UNIT CURB TO REMAIN.
11 REMOVE ROOF MOUNTED ANTENNA, PATCH AND
REPAIR PENETRATIONS.
12 EXISTING RECESSED LIGHT FIXTURE UNDER
OVERHANG.
14 EXISTING ROOF VALLEY.
15 EXISTING ROOF RIDGE.
16 EXISTING PARAPET.
17 REMOVE PAD FOR INSTALATION OF NEW
MECHANICAL CURB.
NORTH
FIRST FLOOR
100' - 0"
REMOVE WOOD SIDING, TYPICAL
REMOVE FASCIA TRIM, TYPICAL
REMOVE RAKE TRIM, TYPICAL EXISTING EXPOSED
CONCRETE MASONRY
UNITS (CMU) TO REMAIN
EXISTING EXPOSED
CONCRETE MASONRY
UNITS (CMU) TO REMAIN
EXISTING OVERHEAD DOOR TO
REMAIN, TYPICAL
8 6 6
55 5
2219 19
18181817
FIRST FLOOR
100' - 0"
REMOVE WOOD SIDING, TYPICAL
REMOVE FASCIA TRIM, TYPICAL
REMOVE BALLASTED EPDM
ROOF, TYPICAL
EXISTING WINDOW TO
REMAIN, PROTECT
WINDOW TRIM DURING
CONSTRUCTION, TYPICAL
TYPICAL BETWEEN
CLERESTORY WINDOWS
15 15 15 15
FIRST FLOOR
100' - 0"
REMOVE WOOD SIDING, TYPICAL REMOVE FASCIA TRIM, TYPICAL
REMOVE RAKE TRIM, TYPICAL REMOVE BALLASTED EPDM
ROOF, TYPICAL
103 1111 88 812 13
TYPICAL
HIDDEN PORTION
OF ELEVATION,
SEE ABOVE
17 18
EXISTING MAN DOOR TO
REMAIN, TYPICAL
TYPICAL BETWEEN
CLERESTORY WINDOWS
8320 20
23 24
FIRST FLOOR
100' - 0"
REMOVE WOOD SIDING, TYPICAL
REMOVE FASCIA TRIM, TYPICALREMOVE RAKE TRIM, TYPICAL
REMOVE METAL SIDING, TYPICAL
REMOVE BALLASTED EPDM
ROOF, TYPICAL
6 6
17 20 20
4 8
FIRST FLOOR
100' - 0"
REMOVE WOOD SIDING, TYPICAL
REMOVE METAL SIDING, TYPICAL
REMOVE METAL SIDING, TYPICAL
REMOVE FASCIA TRIM, TYPICAL
FIRST FLOOR
100' - 0"
REMOVE WOOD SIDING, TYPICAL
REMOVE FASCIA
TRIM, TYPICAL
REMOVE METAL SIDING, TYPICAL
FIRST FLOOR
100' - 0"
REMOVE WOOD SIDING, TYPICAL
REMOVE FASCIA TRIM, TYPICAL
1620 20 20 20
FIRST FLOOR
100' - 0"
REMOVE METAL SIDING, TYPICAL
FIRST FLOOR
100' - 0"
REMOVE WOOD
SIDING, TYPICAL
REMOVE FASCIA
TRIM, TYPICAL
FIRST FLOOR
100' - 0"
REMOVE WOOD
SIDING, TYPICAL
FIRST FLOOR
100' - 0"
REMOVE WOOD
SIDING, TYPICAL
REMOVE RAKE
TRIM, TYPICAL
FIRST FLOOR
100' - 0"
REMOVE WOOD
SIDING, TYPICAL
REMOVE FASCIA
TRIM, TYPICAL
FIRST FLOOR
100' - 0"
REMOVE WOOD
SIDING, TYPICAL
REMOVE RAKE
TRIM, TYPICAL
FIRST FLOOR
100' - 0"
REMOVE WOOD
SIDING, TYPICAL
REMOVE FASCIA
TRIM, TYPICAL
FIRST FLOOR
100' - 0"
REMOVE FASCIA
TRIM, TYPICAL
EXISTING EXPOSED
CONCRETE
MASONRY UNITS
(CMU) TO REMAIN
ARCHITECTURE
ENGINEERING
INTERIOR DESIGN
STRANG, INC.
6411 MINERAL POINT ROAD
MADISON, WI 53705-4395
SHEET NAME
PROJECT TITLE
DRAWING SET
DRAWN
CHECKED
DATE
PROJECT NO.
SHEET NO.
CONSTRUCTION
DOCUMENT SET
FOR
CONSTRUCTION
TC
12/21/2016
AH/TZ
1831 E. US HIGHWAY 169
GRAND RAPIDS, MN 55744
USDA FOREST
SERVICE -
NORTHERN
RESEARCH
STATION - ROOF &
SIDING UPGRADE
2012012.04
CD
DEMOLITION
EXTERIOR
ELEVATIONS
A141
SCALE: 1/8" = 1'-0"A141
1 NORTH ELEVATION
SCALE: 1/8" = 1'-0"A141
2 SOUTH ELEVATION
SCALE: 1/8" = 1'-0"A141
3 EAST ELEVATION
SCALE: 1/8" = 1'-0"A141
4 WEST ELEVATION
SCALE: 1/8" = 1'-0"A141
5 HIDDEN ELEVATION SOUTH
SCALE: 1/8" = 1'-0"A141
6 HIDDEN ELEVATION WEST
SCALE: 1/8" = 1'-0"A141
7 HIDDEN ELEVATION NORTH
SCALE: 1/8" = 1'-0"A141
8 HIDDEN ELEVATION EAST
0' 4' 8'0' 4' 8'
0' 4' 8'
0' 4' 8'
0' 4' 8' 0' 4' 8' 0' 4' 8' 0' 4' 8'
SPECIFIC DEMOLITION EXTERIOR ELEVATION NOTES
1 EXISTING GAS METER TO REMAIN.
2 EXISTING GENERATOR TO REMAIN.
3 EXISTING ELECTRIC CONDUIT TO REMAIN.
4 EXISTIING LOUVER TO REMAIN.
5 EXISTING EXHAUST VENT TO REMAIN.
6 REMOVE DOWNSPOUT FOR INSTALLATION OF NEW
DOWNSPOUT.
7 EXISTING ELECTRIC JUNCTION BOX TO REMAIN.
8 EXISTING LIGHT FIXTURE TO REMAIN.
9 REMOVE EXHAUST VENT.
10 EXISTING AIR CONDITIONER TO REMAIN.
11 EXISTING AIR CONDITIONER LINES TO REMAIN.
12 REMOVE EXISTING VENT.
13 EXISTING DUST COLLECTOR SYSTEM TO REMAIN.
14 RELOCATE FENCE POST AWAY FROM BUILDING.
15 EXISTING METAL TRIM TO REMAIN.
16 EXISTING SENSOR TO REMAIN.
17 REMOVE HOSE BIB FOR INSTALLATION OF NEW HOSE BIB.
18 REMOVE WINDOW FOR INSTALLATION OF NEW WINDOW.
19 REMOVE DOOR AND FRAME FOR INSTALLATION OF NEW
DOOR AND FRAME.
20 REMOVE ELECTRIC OUTLET FOR INSTALLATION OF NEW
ELECTRIC OUTLET.
21 REMOVE METAL TRIM.
22 REMOVE CONDUIT.
23 REMOVE ELECTRIC BOX FOR INSTALLATION OF NEW
ELECTRIC BOX.
24 EXISTING FIRE ALARM TO REMAIN.
SCALE: 1/8" = 1'-0"A141
9 HIDDEN ELEVATION SOUTH 9
SCALE: 1/8" = 1'-0"A141
10 HIDDEN ELEVATION NORTH 10
SCALE: 1/8" = 1'-0"A141
11 HIDDEN ELEVATION SOUTH 11
SCALE: 1/8" = 1'-0"A141
12 HIDDEN ELEVATION NORTH 12
SCALE: 1/8" = 1'-0"A141
13 HIDDEN ELEVATION NORTH 13
SCALE: 1/8" = 1'-0"A141
14 HIDDEN ELEVATION SOUTH 14
SCALE: 1/8" = 1'-0"A141
15 HIDDEN ELEVATION WEST 15
0' 4' 8' 0' 4' 8' 0' 4' 8' 0' 4' 8' 0' 4' 8' 0' 4' 8' 0' 4' 8'
GENERAL DEMOLITION EXTERIOR ELEVATION NOTES
1 ALL EXISTING PENETRATIONS AND ATTACHMENTS ON EXTERIOR
WALLS THAT ARE TO REMAIN SHALL BE MODIFIED AS NECESSARY
TO ACCOMMODATE NEW EXTERIOR WALL ASSEMBLY THICKNESS,
PROVIDE FLUSH MOUNTED COVER PLATES UNLESS NOTED
OTHERWISE.
A401
A401
A401
A401
A401
CONFERENCE
ENTRY
OFFICE/LAB
GIS
SHOP/GARAGE
STORAGE
HEADHOUSE
ARCHIVE
PHASE 1 (SIDING)
A501
A501
A501
A501
A501
A501
A501
A501
A501
A501
SIM
A501
SIM
A501
SIM
A501
SIM
A501
SIM
A501
A501
A501
SIM
A501
SIM
A501
SIM
A501
SIM
A501
SIM
A501
SIM
A501
SIM
A501
SIM
A141
A141
A141
A141
A141
A141
A501
SIM
A401
A401
A401
A401
A401
A401
A806
A806
3&4
A806
MIR
A806
A401
A401
A401
A401
A401
A401
A401
A801
A802
A801
A802
A801
A802
A803
A803
A803
A801
A802
A801
A802
A801
A802
SIM
A801
A801
A801
A802
A802
A803
A802
MIR
A806
A806
A802
A806
A806
MIR
SIM
MIR
3 3
33 3
3 3
3 3
3 3 4
4 4
A806
A803
5 5
005A
005B 005C
002A
ARCHITECTURE
ENGINEERING
INTERIOR DESIGN
STRANG, INC.
6411 MINERAL POINT ROAD
MADISON, WI 53705-4395
SHEET NAME
PROJECT TITLE
DRAWING SET
DRAWN
CHECKED
DATE
PROJECT NO.
SHEET NO.
CONSTRUCTION
DOCUMENT SET
FOR
CONSTRUCTION
TC
12/21/2016
AH/TZ
1831 E. US HIGHWAY 169
GRAND RAPIDS, MN 55744
USDA FOREST
SERVICE -
NORTHERN
RESEARCH
STATION - ROOF &
SIDING UPGRADE
2012012.04
CD
FIRST FLOOR
PLAN
A201
SCALE: 1/8" = 1'-0"
A201
FIRST FLOOR PLAN
0' 4' 8'
GENERAL PLAN NOTES
1 ALL DRAWINGS ARE OF EQUAL IMPORTANCE IN
DEFINING THE WORK OF THE CONTRACT
DOCUMENTS. CONTRACTORS SHALL CAREFULLY
STUDY AND COMPARE ALL DRAWINGS DURING THE
BIDDING PERIOD AND BEFORE INSTALLATION OF
THEIR WORK. ANY INCONSISTENCIES IN THE
DRAWING SHALL BE REPORTED PROMPTLY TO THE
CONTRACTING OFFICER FOR CLARIFICATION.
2 DO NOT SCALE DRAWINGS. THE DRAWINGS ARE NOT
NECESSARILY TO SCALE - USE GIVEN DIMENSIONS.
CONTRACTORS SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS AT THE PROJECTS SITE PRIOR TO THE
START OF CONSTRUCTION. ANY INCONSISTENCIES
DISCOVERED BY THE CONTRACTOR SHALL BE
REPORTED PROMPTLY TO THE CONTRACTING
OFFICER FOR CLARIFICATION BEFORE COMMENCING
THE WORK. ALL DIMENSIONS ARE GIVEN FROM FACE
TO FACE OF WALL. SEE WALL SECTIONS AND
PARTITION TYPES FOR EXACT CONSTRUCTION.
3 WHERE SPECIFIC DIMENSIONS, DETAILS OR DESIGN
INTENT CANNOT BE DETERMINED FROM DOCUMENTS
CONSULT THE CONTRACTING OFFICER BEFORE
PROCEEDING WITH WORK.
4 PROTECT WORK IN PLACE DURING CONSTRUCTION.
5 COORDINATE THE AVAILABILITY OF AREAS
REQUIRING WORK WITH THE CONTRACTING
OFFICER.
6 REFER TO HVAC, ELECTRICAL, PLUMBING, AND FIRE
PROTECTION NOTES FOR ADDITIONAL DEMOLITION
AND MODIFICATIONS REQUIRED FOR HVAC,
ELECTRICAL, PLUMBING AND FIRE PROTECTION
SYSTEMS.
SPECIFIC FLOOR PLAN NOTES
1 DORMER ABOVE FLOOR PLAN CUT LEVEL FOR
REFERENCE.
2 PORTION OF WALL TO HAVE 1" RIGID INSULATION IN
LIEU OF 2" RIGID INSULATION FROM FLOOR BASE TO
ROOF AND FROM WINDOW/DOOR ASSEMBLY TO
WINDOOW/DOOR ASSEMBLY, REFER TO DETAIL 3
AND 4/A806.
3 VERTICAL POST, REFER TO TYPICAL DETAIL 1 AND
2/A804.
4 VERTICAL POST AT CORNER, REFER TO TYPICAL
DETAIL 7 AND 8/A806 AND 5/A803. POST LOCATED
ADJACENT TO WINDOWS TO HAVE POST EXTEND TO
WINDOW OPENING SIMILAR TO DETAIL 10/A806,
LENGTH TO WINDOW VARIES.
5 NEW DOOR AND FRAME, SEE DOOR SCHEDULE.
6 EXISITNG INFILL WALL THAT IS RECESSED 3/4" FROM
SURROUNDING EXISTING CMU WALL, INSTALL NEW
3/4" GLASS MAT SHEATHING TO BE FLUSH WITH
EXISTING CMU WALL.
NORTH
DOOR NUMBER MATERIAL HARDWARE SET COMMENT
002A AL SEE SECTION 08 42 13
005A HM 1 4" HEAD
005B HM 2 4" HEAD
005C HM 1 4" HEAD
KEY
AL - ALUMINUM
HM - HOLLOW METAL
DOOR SCHEDULE
REV 03/11/2019
FULLY ADHERED EPDM TO REMAIN
FULLY ADHERED EPDM TO REMAIN
FULLY ADHERED EPDM TO REMAIN
FULLY ADHERED EPDM TO REMAIN
NEW FULLY
ADHERED EPDM
ROOF WITH MINIMUM
4' RIGID INSULATION
A501
A501
A501
A501
A501
A501
A501
A501
A501
10' - 0"
A501
SIM
A501
SIM
A501
SIM
A501
SIM
A501
SIM
A501
SIM
A501
A501
A501
SIM
A501
SIM
A501
SIM
A501
SIM
A501
SIM
A501
SIM
A501
SIM
A501
SIM
A501
SIM
ROOF SLOPE
ROOF SLOPE
ROOF SLOPE
ROOF SLOPE ROOF SLOPE
ROOF SLOPE
NEW FULLY
ADHERED EPDM
ROOF WITH MINIMUM
4' RIGID INSULATION
NEW FULLY
ADHERED EPDM
ROOF WITH MINIMUM
4' RIGID INSULATION
NEW FULLY
ADHERED EPDM
ROOF WITH MINIMUM
4' RIGID INSULATION
NEW FULLY
ADHERED EPDM
ROOF WITH MINIMUM
4' RIGID INSULATION
NEW FULLY
ADHERED EPDM
ROOF WITH MINIMUM
4' RIGID INSULATION
NEW FULLY
ADHERED EPDM
ROOF WITH MINIMUM
4' RIGID INSULATION
NEW FULLY
ADHERED EPDM
ROOF WITH MINIMUM
4' RIGID INSULATION
6 6
6 6
6 6
ROOF SLOPE
A804
A804
A804
A804
A804
13 SIM
A804
SIM
A805
A805
A805
ROOF SLOPE
4 4
ARCHITECTURE
ENGINEERING
INTERIOR DESIGN
STRANG, INC.
6411 MINERAL POINT ROAD
MADISON, WI 53705-4395
SHEET NAME
PROJECT TITLE
DRAWING SET
DRAWN
CHECKED
DATE
PROJECT NO.
SHEET NO.
CONSTRUCTION
DOCUMENT SET
FOR
CONSTRUCTION
TC
12/21/2016
AH/TZ
1831 E. US HIGHWAY 169
GRAND RAPIDS, MN 55744
USDA FOREST
SERVICE -
NORTHERN
RESEARCH
STATION - ROOF &
SIDING UPGRADE
2012012.04
CD
ROOF PLAN
A202
SCALE: 1/8" = 1'-0"
A202
ROOF PLAN.
GENERAL PLAN NOTES
1 ALL DRAWINGS ARE OF EQUAL IMPORTANCE IN
DEFINING THE WORK OF THE CONTRACT
DOCUMENTS. CONTRACTORS SHALL CAREFULLY
STUDY AND COMPARE ALL DRAWINGS DURING THE
BIDDING PERIOD AND BEFORE INSTALLATION OF
THEIR WORK. ANY INCONSISTENCIES IN THE
DRAWING SHALL BE REPORTED PROMPTLY TO THE
CONTRACTING OFFICER FOR CLARIFICATION.
2 DO NOT SCALE DRAWINGS. THE DRAWINGS ARE NOT
NECESSARILY TO SCALE - USE GIVEN DIMENSIONS.
CONTRACTORS SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS AT THE PROJECTS SITE PRIOR TO THE
START OF CONSTRUCTION. ANY INCONSISTENCIES
DISCOVERED BY THE CONTRACTOR SHALL BE
REPORTED PROMPTLY TO THE CONTRACTING
OFFICER FOR CLARIFICATION BEFORE COMMENCING
THE WORK. ALL DIMENSIONS ARE GIVEN FROM FACE
TO FACE OF WALL. SEE WALL SECTIONS AND
PARTITION TYPES FOR EXACT CONSTRUCTION.
3 WHERE SPECIFIC DIMENSIONS, DETAILS OR DESIGN
INTENT CANNOT BE DETERMINED FROM DOCUMENTS
CONSULT THE CONTRACTING OFFICER BEFORE
PROCEEDING WITH WORK.
4 PROTECT WORK IN PLACE DURING CONSTRUCTION.
5 COORDINATE THE AVAILABILITY OF AREAS
REQUIRING WORK WITH THE CONTRACTING
OFFICER.
6 REFER TO HVAC, ELECTRICAL, PLUMBING, AND FIRE
PROTECTION NOTES FOR ADDITIONAL DEMOLITION
AND MODIFICATIONS REQUIRED FOR HVAC,
ELECTRICAL, PLUMBING AND FIRE PROTECTION
SYSTEMS.
SPECIFIC ROOF PLAN NOTES
1 BASE BID - NEW ROOF ASSEMBLY ADD TO EXISTING
RIGID INSULATION TO HAVE A MINIMUM OF 4" OF
TOTAL RIGID INSULATION. ADD-ALT: NEW
ROOF ASSEMBLY TO HAVE ALL NEW MINIMUM OF 4"
TOTAL RIGID INSULATION.
2 NEW FASCIA AND RAKE TRIM FINISH, TYPICAL
AROUND BUILDING, REFER TO DETAIL 1,2,3 AND
6/A805.
3 EXISTING EXHAUST HOOD CURB, REFER TO DETAIL
7/A804.
4 EXISTING ROOF PENETRATIONS, REFER TO DETAIL
10 AND 11/A804.
5 NEW SCUPPER, REFER TO DETAIL 15/A804.
6 EXISTING SKYLIGHT CURB, REFER TO DETAIL 9/A804.
7 NEW DOWNSPOUT.
8 EXISTING OVERHANG, REFER TO DETAIL 12/A804, 2
AND 3 A/805.
9 NEW SOFFIT VENT.
10 EXISTING AIR HANDLING UNIT CURB, REFER TO
DETAIL 8/A804.
11 EXISTING PARAPET, REFER TO DETAIL 14/A804.
12 EXISTING RECESSED LIGHT FIXTURE UNDER
OVERHANG.
14 EXISTING ROOF VALLEY.
15 EXISTING ROOF RIDGE.
16 ALL VENTS TO BE SEALED AIR TIGHT WHERE NEW
DENSE PACK FIBERGLASS INSULATION IS TO BE
INSTALLED.
17 DASHED AREA TO HAVE DENSE PACK FIBERGLASS
INSULATION INSTALLED OVER EXISTING INSULATION
WITHIN ROOF ALONG PERIMETER EXTERIOR, FILL
VOID FULL WITH INSULATION, FILL RIM JOIST.
18 NEW GUTTER.
19 WRAP ROOF MEMEBRANE UP VERTICAL PARAPET
WALL OVER 1/2" PLYWOOD AND 2" RIGID INSULATION
OVER EXISTING SHEATHING, REFER TO DETAIL
16/A804.
20 NEW MECHANICAL CURB INSTALLED IN PLACE OF
PAD, INSTALL PER 7/A804 (SIM.) AND INSTALL
COUNTERFLASHING MINIMUM 8" ABOVE FULLY
ADHERED EPDM MEMBRANE ROOFING.
21 HATCHED AREA TO HAVE DENSE PACK FIBERGLASS
INSULATION INSTALLED OVER EXISTING INSULATION
WITHIN ROOF ALONG PERIMETER EXTERIOR, FILL
VOID FULL WITH INSULATION, FILL CAVITY SPACE.
22 OLD SKYLIGHT FRAMING TO REMAIN, DENSE PACK
FIBERGLASS INSULATION TO BE INSTALLED
AROUND FRAMING.
0' 4' 8'
NORTH
CONCEALED FASTNER
METAL PANEL (MP-2),
TYPICAL
METAL
HORIZONTAL TRIM
BAND (M-1), TYPICAL
CONCEALED FASTENER
CORRUGATED HORIZONTAL
METAL PANEL (MP-1), TYPICAL
FULLY ADHERED
EPDM ROOF (R-1),
TYPICAL
VERTICAL POST
(M-2), TYPICAL
FASCIA TRIM (FT-1),
TYPICAL
RAKE TRIM (RT-1),
TYPICAL
A501
A501
5 5 5
6 6
6 68 18 18 18
UPPER HORIZONTAL
BAND, REFER TO
DETAIL 3 AND 4/A804,
TYPICAL
LOWER HORIZONTAL
BAND, REFER TO
DETAIL 5 AND 6/A804,
TYPICAL
VERTICAL POST,
REFER TO DETAIL 1
AND 2/A804, TYPICAL
M-1 MP-1
MP-2 MP-2
M-1 MP-1
MP-2MP-2
FT-1
M-2
M-1 MP-2
MP-1 2222
M-2
M-2
M-2
M-2
M-2
M-2
M-2
SOFFIT
PANEL (S-1)
VERTICAL POST
@ EXPOSED TOP
CONDITION, REFER
TO DETAIL 9/A806
3 17
FIRST FLOOR
100' - 0"
CULTURED STONE
(CS-1), TYPICAL
S-1
EXISTING WINDOWS,
TYPICAL
R-1
R-1 RT-1FT-1 FT-1
M-2
MP-2
M-1
MP-2
MP-1
MP-1 M-2 M-1
A501
A501
A501
M-2M-2
M-2
M-2
M-2 M-2 M-2 M-2
M-2 M-2 M-2
M-1 M-1 M-1
M-1
MP-2
MP-2S-1 M-3
MP-2
EXISTING WINDOW,
TYPICAL
MP-1
S-1
S-1
S-1
TYPICAL
BETWEEN
CLERESTORY
WINDOWS
15 VERTICAL POST
@ EXPOSED TOP
CONDITION, REFER
TO DETAIL 2/A806
FT-1
VERTICAL
TRANSITION,
REFER TO DETAIL 15
AND 16/A802, TYPICAL
15 15
FIRST FLOOR
100' - 0"
CS-1
R-1
S-1
M-2
MP-2
M-1
MP-2MP-1
EXISTING WINDOW,
TYPICAL
RT-1
FT-1
P-2
P-2 P-2 MP-1 M-2 P-2
MP-2
S-1 M-1
FT-1
MP-2
A501
M-1
M-2
M-2
M-2M-2M-2M-2M-2
M-2
M-1
".8
MP-2
M-2M-2
M-2 CS-1
EXISTING DOOR AND
FRAME, PAINT (P-2), TYPICAL
3 8 8 824 10 1111 13
17 18
M-1
RT-1
RT-1
MP-1
M-3 15
TYPICAL
BETWEEN
CLERESTORY
WINDOWS
HIDDEN PORTION
OF ELEVATION,
SEE ABOVE
FT-1
MP-2
FIRST FLOOR
100' - 0"
CS-1
EXISTING WINDOWS,
TYPICAL
R-1
M-2
MP-2
M-1
MP-2
MP-1
RT-1
FT-1
P-2 P-2 MP-1M-2
MP-2
S-1
M-1
RT-1
MP-2
M-1M-2
S-1
S-1
P-2
M-2
A501
A501
P-2 P-2
M-2
M-2
M-2
M-2 M-2
M-2
M-2
M-2
BEYOND
M-2
M-2
3 3 3
46 6 6
10 101114
M-1
M-1
M-1
MP-1MP-2
MP-1
MP-2
MP-2
EXISTING WINDOWS,
TYPICAL
CS-1
M-1
FIRST FLOOR
100' - 0"
FT-1
EXISTING WINDOWS, TYPICAL
MP-2P-2MP-1
A501
M-2 M-2
M-2 M-2 M-2M-1
M-1
M-1
MP-2
MP-1
MP-2
S-1
FIRST FLOOR
100' - 0"
FT-1
MP-2 P-2MP-1M-1 M-2
FT-1 R-1
" M-2 M-213 M-2 MP-1M-1
8 S-18
FIRST FLOOR
100' - 0"
EXISTING WINDOWS, TYPICAL
MP-2MP-1M-1 M-2
M-2
FIRST FLOOR
100' - 0"
FT-1
MP-2MP-1M-1 M-2
R-1 S-1
M-2 M-2 M-2
M-2
20202020
FIRST FLOOR
100' - 0"
M-1MP-2
M-2 MP-1
FT-1
FIRST FLOOR
100' - 0"
M-1
MP-2
M-2
MP-1
FT-1
FIRST FLOOR
100' - 0"
M-1
MP-1
MP-2
RT-1
M-2
S-1
FIRST FLOOR
100' - 0"
M-1
MP-1
MP-2
FT-1
M-2
S-1
FIRST FLOOR
100' - 0"
M-1
MP-1
MP-2
RT-1
M-2
S-1
FIRST FLOOR
100' - 0"
M-1
MP-1
MP-2
FT-1
M-2
FIRST FLOOR
100' - 0"
FT-1
MP-1
MP-2
M-1 M-2
ARCHITECTURE
ENGINEERING
INTERIOR DESIGN
STRANG, INC.
6411 MINERAL POINT ROAD
MADISON, WI 53705-4395
SHEET NAME
PROJECT TITLE
DRAWING SET
DRAWN
CHECKED
DATE
PROJECT NO.
SHEET NO.
CONSTRUCTION
DOCUMENT SET
FOR
CONSTRUCTION
TC
12/21/2016
AH/TZ
1831 E. US HIGHWAY 169
GRAND RAPIDS, MN 55744
USDA FOREST
SERVICE -
NORTHERN
RESEARCH
STATION - ROOF &
SIDING UPGRADE
2012012.04
CD
EXTERIOR
ELEVATIONS
A401
SCALE: 1/8" = 1'-0"A401
1 NORTH ELEVATION
SCALE: 1/8" = 1'-0"A401
2 SOUTH ELEVATION
SCALE: 1/8" = 1'-0"A401
3 EAST ELEVATION
SCALE: 1/8" = 1'-0"A401
4 WEST ELEVATION
SCALE: 1/8" = 1'-0"A401
5 HIDDEN ELEVATION SOUTH
SCALE: 1/8" = 1'-0"A401
6 HIDDEN ELEVATION WEST
SCALE: 1/8" = 1'-0"A401
8 HIDDEN ELEVATION EAST
SCALE: 1/8" = 1'-0"A401
7 HIDDEN ELEVATION NORTH
0' 4' 8' 0' 4' 8'
0' 4' 8'
0' 4' 8'
0' 4' 8' 0' 4' 8' 0' 4' 8' 0' 4' 8'
EXTERIOR FINISH SCHEDULE
MP-1 CONCEALED FASTENER
CORRUGATED METAL PANEL
FIRESTONE CFP-16F
(HORIZONTAL)
MP-2 CONCEALED FASTENER
CORRUGATED METAL PANEL
FIRESTONE CFP-12 (VERTICAL
AND HORIZONTAL)
CS-1 CULTURERED STONE BORAL
M-1 METAL TRIM OVER 2X4 BLOCKING
(HORIZONTAL BAND)
M-2 METAL TRIM OVER 2X4 BLOCKING
AND PLYWOOD (VERTICAL POST)
M-3 METAL TRIM OVER RIGID
INSULATION
P-1 PAINT EXISTING OVERHEAD DOOR
AND TRIM
SHERWIN WILLIAMS
P-2 PAINT EXISTING MAN DOOR AND
FRAME
SHERWIN WILLIAMS
FT-1 FASCIA TRIM -----
RT-1 RAKE TRIM -----
S-1 SOFFIT FIRESTONE CFP-12
R-1 FULLY ADHERED EPDM
MEMBRANE ROOFING
GENERAL EXTERIOR ELEVATION NOTES.
1 PAINT EXISTING PIPING, CONDUIT, JUNCTION BOXES, HOSES, VENT
COVERS AND PENETRATIONS THROUGH WALLS, COLOR TO MATCH
ADJACENT FINISH MATERIAL, REFER TO DETAIL 11/A806 FOR
PENETRATIONS AT METAL PANELS.
SPECIFIC NEW ELEVATION NOTES
1 GAS METER.
2 GENERATOR.
3 ELECTRIC CONDUIT.
4 LOUVER, PAINT TO MATCH ADJACENT METAL PANEL COLOR.
5 EXHAUST VENT.
6 NEW DOWNSPOUT, COLOR TO MATCH FASCIA COLOR.
7 ELECTRIC JUNCTION BOX, REFER TO ELECTRICAL NOTES ON SHEET
T001.
8 LIGHT FIXTURE.
9 NEW ELECTRIC BOX.
10 AIR CONDITIONER.
11 AIR CONDITIONER LINES. FABRICATE NEW COVERS, MATCH
ADJACENT SIDING COLOR.
12 NEW METAL TRIM, PAINT TO MATCH M-2 VERTICAL POSTS.
13 DUST COLLECTION SYSTEM.
14 RELOCATED FENCE POST, PLACE MAXIMUM 4" AWAY FROM OUTER
EDGE OF BUILDING.
15 EXISTING METAL TRIM, PAINT TO MATCH M-2 VERTICAL POSTS.
16 SENSOR.
17 NEW HOSE BIB, FIXTURE EQUAL TO WOODFORD MODEL 67,
BACKFLOW PROTECTED FREEZELESS, CONNECT TO EXISTING PIPING
AS REQUIRED, VERIFY ASSEMBLY SIZE WITH WALL THICKNESS.
18 NEW WINDOW TO MATCH EXISTING.
19 NEW DOOR AND FRAME, PAINT (P-2).
20 NEW ELECTRICAL OUTLET, COVER PLATE TO MATCH ADJACENT
METAL PANEL COLOR.
21 EXISTING DOOR AND FRAME, SCRAPE PAINT AND PREP FOR NEW
PAINT (P-2).
22 EXISTING OVERHEAD DOOR AND FRAME, PAINT (P-1).
24 NEW GFCI ELECTRIC OUTLET WITH COVER, MATCH ADJACENT METAL
PANEL COLOR, REFER TO ELECTRICAL NOTES ON T001.
25 UPPER AND LOWER HORIZONTAL BAND IN THIS AREA WHERE 1"
INSULATION IS USED TO HAVE THE HORIZONTAL BAND MADE UP OF
TRANSITION TRIM SIMILAR TO WHAT IS SHOWN ON DETAIL 15/A802,
COLOR TO MATCH HORIZONTAL BAND COLOR USED ON OTHER AREAS
OF BUILDING.
26 FIRE ALARM.
27 CULTURED STONE STARTER TO BE 2" ABOVE STOOP WITH PRECAST
STONE CURB BETWEEN STOOP AND CULTURED STONE STARTER.
SCALE: 1/8" = 1'-0"A401
9 HIDDEN ELEVATION SOUTH 9.
SCALE: 1/8" = 1'-0"A401
10 HIDDEN ELEVATION NORTH 10.
SCALE: 1/8" = 1'-0"A401
11 HIDDEN ELEVATION SOUTH 11.
SCALE: 1/8" = 1'-0"A401
12 HIDDEN ELEVATION NORTH 12.
SCALE: 1/8" = 1'-0"A401
13 HIDDEN ELEVATION NORTH 13.
SCALE: 1/8" = 1'-0"A401
14 HIDDEN ELEVATION SOUTH 14.
SCALE: 1/8" = 1'-0"A401
15 HIDDEN ELEVATION WEST 15.
0' 4' 8' 0' 4' 8' 0' 4' 8' 0' 4' 8' 0' 4' 8' 0' 4' 8' 0' 4' 8'
2" RIGID INSULATION
CONCEALED FASTNER
CORRUGATED HORIZONTAL
METAL PANEL (MP-1)
FLUID APPLIED AIR BARRIER
OVER EXISTING SHEATHING
EXISTINGNEW
PREFINISHED METAL TRIM
OVER RIGID INSULATION
A801
EXISTING WINDOW
A805
SIM
FULLY ADHERED EPDM
MEMBRANE ROOFING
4" MINIMUM RIGID INSULATION
A801
FIRST FLOOR
100' - 0"
EXISTINGNEW
2" RIGID INSULATION
CONCEALED FASTNER
CORRUGATED HORIZONTAL
METAL PANEL (MP-1)
FLUID APPLIED AIR BARRIER
OVER EXISTING SHEATHING
PREFINISHED METAL TRIM
OVER RIGID INSULATION
EXISTING WINDOW
FULLY ADHERED EPDM
MEMBRANE ROOFING
4" MINIMUM RIGID INSULATION
A801
A805
A801
SIM
FIRST FLOOR
100' - 0"
2" RIGID INSULATION
CONCEALED FASTENER
CORRUGATED HORIZONTAL
METAL PANEL (MP-1)
7/8" HAT CHANNELS
FLUID APPLIED AIR BARRIER
OVER EXISTING SHEATHING
EXISTINGNEW
CONCEALED FASTENER
CORRUGATED VERTICAL
METAL PANEL (MP-2)
A805
EXISTING WINDOW
FULLY ADHERED EPDM
MEMBRANE ROOFING
4" MINIMUM RIGID INSULATION
A801
A801
SIM
A802
SIM
FIRST FLOOR
100' - 0"
2" RIGID INSULATION
CONCEALED FASTNER
CORRUGATED HORIZONTAL
METAL PANEL (MP-1)
7/8" HAT CHANNELS
EXISTINGNEW
CONCEALED FASTNER
CORRUGATED HORIZONTAL
METAL PANEL (MP-2)
CONCEALED FASTNER
CORRUGATED HORIZONTAL
METAL PANEL (MP-2)
FLUID APPLIED AIR BARRIER
OVER EXISTING CMU
A802
A801
A801
A805
SIM
SIM
EXISTING FULLY ADHERED EPDM
MEMBRANE ROOFING
DENSE PACK FIBERGLASS
INSULATION OVER EXISTING
INSULATION, FIILL CAVITY FULL
WITH INSULATION
A804
SIM
FIRST FLOOR
100' - 0"
EXISTINGNEW
EXISTING OVERHEAD
DOOR
2" RIGID INSULATION
7/8" HAT CHANNELS
CONCEALED FASTNER
CORRUGATED HORIZONTAL
METAL PANEL (MP-2)
FLUID APPLIED AIR BARRIER
OVER EXISTING CMU
A802
SIM
EXISTING FULLY ADHERED EPDM
MEMBRANE ROOFING
DENSE PACK FIBERGLASS
INSULATION OVER EXISTING
INSULATION, FIILL CAVITY FULL
WITH INSULATION
A805
FIRST FLOOR
100' - 0"
EXISTINGNEW
2" RIGID INSULATION
CONCEALED FASTNER
CORRUGATED HORIZONTAL
METAL PANEL (MP-1)
7/8" HAT CHANNELS
CONCEALED FASTNER
CORRUGATED VERTICAL
METAL PANEL (MP-2)
CONCEALED FASTNER
CORRUGATED HORIZONTAL
METAL PANEL (MP-2)
FLUID APPLIED AIR BARRIER
OVER EXISTING SHEATHING
A801
A801
SIM
A805
SIM
FULLY ADHERED EPDM
MEMBRANE ROOFING
4" MINIMUM RIGID INSULATION
A801
A802
SIM
A804
FIRST FLOOR
100' - 0"
EXISTINGNEW
2" RIGID INSULATION
CONCEALED FASTENER
CORRUGATED HORIZONTAL
METAL PANEL (MP-2)
7/8" HAT CHANNELS
FLUID APPLIED AIR BARRIER
OVER EXISTING SHEATHING
CONCEALED FASTENER
CORRUGATED HORIZONTAL
METAL PANEL (MP-2)
CONCEALED FASTENER
CORRUGATED HORIZONTAL
METAL PANEL (MP-1)
A805
EXISTING FULLY ADHERED
EPDM MEMBRANE ROOFING
A802
SIM
A801
A804
SIM
2" RIGID INSULATION
CULTURED STONE VENEER
EXISTINGNEW
LATH AND MORTAR
SETTING BED
CONCEALED FASTENER
CORRUGATED HORIZONTAL
METAL PANEL (MP-2)
7/8" HAT CHANNELS
FLUID APPLIED AIR BARRIER
OVER EXISTING SHEATHING
FULLY ADHERED EPDM
MEMBRANE ROOFING
4" MINIMUM RIGID INSULATION
A805
A804
SIM
A803
MIR
EXISTINGNEW
2" RIGID INSULATION
CULTURED STONE VENEER
LATH AND MORTAR
SETTING BED
A803
A803
A805
FULLY ADHERED EPDM
MEMBRANE ROOFING
4" MINIMUM RIGID INSULATION
MIR
ARCHITECTURE
ENGINEERING
INTERIOR DESIGN
STRANG, INC.
6411 MINERAL POINT ROAD
MADISON, WI 53705-4395
SHEET NAME
PROJECT TITLE
DRAWING SET
DRAWN
CHECKED
DATE
PROJECT NO.
SHEET NO.
CONSTRUCTION
DOCUMENT SET
FOR
CONSTRUCTION
TC
12/21/2016
AH/TZ
1831 E. US HIGHWAY 169
GRAND RAPIDS, MN 55744
USDA FOREST
SERVICE -
NORTHERN
RESEARCH
STATION - ROOF &
SIDING UPGRADE
2012012.04
CD
WALL SECTIONS
A501
SCALE: 3/4" = 1'-0"
A501
WALL SECTION A
SCALE: 3/4" = 1'-0"
A501
WALL SECTION B
SCALE: 3/4" = 1'-0"
A501
WALL SECTION C
SCALE: 3/4" = 1'-0"
A501
WALL SECTION D
SCALE: 3/4" = 1'-0"
A501
WALL SECTION E
SCALE: 3/4" = 1'-0"
A501
WALL SECTION F
SCALE: 3/4" = 1'-0"
A501
WALL SECTION G
SCALE: 3/4" = 1'-0"
A501
WALL SECTION H
SCALE: 3/4" = 1'-0"
A501
WALL SECTION J
0' 1' 4" 8"
0' 1' 4" 8"
0' 1' 4" 8"
0' 1' 4" 8"
0' 1' 4" 8"
0' 1' 4" 8"
0' 1' 4" 8"
0' 1' 4" 8"
0' 1' 4" 8"
2"7/8"7/8"
EXISTINGNEW
EXISTING SHEATHING
EXISTING STUD WALL
EXISTING GYPSUM BOARD
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 16" O.C.
CONCEALED FASTENER
CORRUGATED
HORIZONTAL METAL
PANEL
EXISTINGNEW
EXISTING SHEATHING
EXISTING STUD WALL
EXISTING GYPSUM BOARD
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 16" O.C.
CONCEALED FASTENER
CORRUGATED
HORIZONTAL METAL
PANEL
EXISTING WINDOW
PREFINISHED METAL FLASHING
(2) 2X4 BLOCKING
WOOD BLOCKING FOR
ATTACHMENT OF
HORIZONTAL TRIM
PITCH TOP OF
HORIZONTAL
TRIM AWAY FROM
BUILDING
SEALANT
HORIZONTAL TRIM
SEALANT, DO NOT COVER UP
WINDOW WEEP HOLES
1 1/4".
2"7/8"7/8"
EXISTINGNEW
EXISTING CMU WALL
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 16" O.C.
CONCEALED FASTENER
CORRUGATED
HORIZONTAL METAL
PANEL
EXISTING SHEATHING
EXISTING STUD WALL
EXISTING GYPSUM BOARD
FLUID APPLIED
AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL @ 16" O.C.
CONCEALED FASTENER CORRUGATED
HORIZONTAL METAL PANEL
EXISTINGNEW
2"7/8"7/8"
PREFINISHED METAL OUTSIDE
CORNER TRIM
3"
METAL PANEL TRIM CLOSURE
EXISTING CMU WALL
FLUID APPLIED
AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL @ 16" O.C.
CONCEALED FASTENER CORRUGATED
HORIZONTAL METAL PANEL
EXISTINGNEW
2"7/8"7/8"
PREFINISHED METAL OUTSIDE
CORNER TRIM
3"
METAL PANEL TRIM CLOSURE
2"7/8"7/8"
EXISTINGNEW
EXISTING SHEATHING
EXISTING STUD WALL
EXISTING GYPSUM BOARD
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 16" O.C.
CONCEALED FASTENER
CORRUGATED
HORIZONTAL METAL
PANEL
2X BLOCKING
PREFINISHED METAL PANAL
BOTTOM CLOSURE TRIM W/
WEEPS, LAP FOUNDATION
SEALANT
GRADE
2"7/8"7/8"
EXISTINGNEW
EXISTING CMU
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 16" O.C.
CONCEALED FASTENER
CORRUGATED
HORIZONTAL METAL
PANEL
2X BLOCKING
PREFINISHED METAL PANAL
BOTTOM CLOSURE TRIM W/
WEEPS, LAP FOUNDATION
SEALANT
GRADE
EXISTINGNEW
EXISTING CMU WALL
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 16" O.C.
CONCEALED FASTENER
CORRUGATED
HORIZONTAL METAL
PANEL
EXISTING WINDOW
PREFINISHED METAL PANEL
CLOSURE TRIM W/ DRIP EDGE
WOOD BLOCKING FOR
ATTACHMENT OF
CLOSURE TRIM
PITCH TOP OF
HORIZONTAL
TRIM AWAY FROM
BUILDING
SEALANT, DO NOT COVER UP
WINDOW WEEP HOLES
E X
IS
T
IN
G
N E
W
EXISTING STUD WALL
EXISTING GYPSUM BOARD
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 16" O.C.
CONCEALED FASTENER
CORRUGATED
HORIZONTAL METAL PANEL
EXISTING SHEATHING
PREFINISHED METAL
PANEL CLOSURE TRIM
EXISTING WINDOW
SEALANT
METAL PANEL TRIM
CLOSURE
E X
IS
T
IN
G
N E
W
EXISTING CMU WALL
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 16" O.C.
CONCEALED FASTENER
CORRUGATED
HORIZONTAL METAL PANEL
PREFINISHED METAL
PANEL CLOSURE TRIM
EXISTING WINDOW
SEALANT
METAL PANEL TRIM
CLOSURE
E X
IS
T
IN
G
N E
W
EXISTING STUD WALL
EXISTING GYPSUM BOARD
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 16" O.C.
CONCEALED FASTENER
CORRUGATED
HORIZONTAL METAL PANEL
EXISTING SHEATHING
PREFINISHED METAL
PANEL CLOSURE TRIM
EXISTING DOOR
EXISTING
DOOR
FRAME
SEALANT
METAL PANEL
TRIM CLOSURE
E X
IS
T
IN
G
N E
W
EXISTING CMU WALL
FLUID APPLIED AIR BARRIER, EXTEND
INTO ROUGH OPENING AS SHOWN
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 16" O.C.
CONCEALED FASTENER
CORRUGATED
HORIZONTAL METAL PANEL
PREFINISHED METAL
PANEL CLOSURE TRIM
DOOR
DOOR
FRAME
SEALANT
SEALANT
METAL PANEL
TRIM CLOSURE
EXISTING STUD WALL
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
PREFINISHED METAL INSIDE
CORNER TRIM
7/8" HAT CHANNEL
@ 16" O.C.
CONCEALED FASTENER
CORRUGATED HORIZONTAL
METAL PANEL
WOOD BLOCKING
E X
IS
T
IN
G
N E
W EXISTING SHEATHING
EXISTING GYPSUM BOARD
/8
/8
EXISTING CMU WALL
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
PREFINISHED METAL INSIDE
CORNER TRIM
CONCEALED FASTENER
CORRUGATED HORIZONTAL
METAL PANEL
WOOD BLOCKING
E X
IS
T
IN
G
N E
W
7/8" HAT CHANNEL
@ 12" O.C.
/8
/8
2"7/8"7/8"
EXISTINGNEW
EXISTING SHEATHING
EXISTING STUD WALL
EXISTING GYPSUM BOARD
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 16" O.C.
CONCEALED FASTENER
CORRUGATED HORIZONTAL
METAL PANEL
1/8" X 1" NON-CURING BUTYL TAPE
M
IN
L A
P
PLAN VIEW
NOTCH BACK FASTENING
FLANGE AND HOOK FOR
OVERLAP CLEARANCE
2"7/8"7/8"
EXISTINGNEW
EXISTING CMU WALL
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 16" O.C.
CONCEALED FASTENER
CORRUGATED HORIZONTAL
METAL PANEL
1/8" X 1" NON-CURING BUTYL TAPE
M
IN
L A
P
PLAN VIEW
NOTCH BACK FASTENING
FLANGE AND HOOK FOR
OVERLAP CLEARANCE
ARCHITECTURE
ENGINEERING
INTERIOR DESIGN
STRANG, INC.
6411 MINERAL POINT ROAD
MADISON, WI 53705-4395
SHEET NAME
PROJECT TITLE
DRAWING SET
DRAWN
CHECKED
DATE
PROJECT NO.
SHEET NO.
CONSTRUCTION
DOCUMENT SET
FOR
CONSTRUCTION
TC
12/21/2016
TZ/TC
1831 E. US HIGHWAY 169
GRAND RAPIDS, MN 55744
USDA FOREST
SERVICE -
NORTHERN
RESEARCH
STATION - ROOF &
SIDING UPGRADE
2012012.04
CD
EXTERIOR
DETAILS
A801
SCALE: 3" = 1'-0"A801
9 (MP-1) SEAM DETAIL @ STUD
SCALE: 3" = 1'-0"A801
3 (MP-1) WINDOW SILL DETAIL @ STUD
SCALE: 3" = 1'-0"A801
10 (MP-1) SEAM DETAIL @ CMU
SCALE: 3" = 1'-0"A801
11 (MP-1) OUTSIDE CORNER DETAIL @ STUD
SCALE: 3" = 1'-0"A801
12 (MP-1) OUTSIDE CORNER DETAIL @ CMU
SCALE: 3" = 1'-0"A801
1 (MP-1) BASE DETAIL @ STUD
SCALE: 3" = 1'-0"A801
2 (MP-1) BASE DETAIL @ CMU
SCALE: 3" = 1'-0"A801
4 (MP-1) WINDOW SILL DETAIL @ CMU
SCALE: 3" = 1'-0"A801
5 (MP-1) WINDOW JAMB DETAIL @ STUD
SCALE: 3" = 1'-0"A801
6 (MP-1) WINDOW JAMB DETAIL @ CMU
SCALE: 3" = 1'-0"A801
7 (MP-1) DOOR JAMB DETAIL @ STUD
SCALE: 3" = 1'-0"A801
8 (MP-1) DOOR JAMB DETAIL @ CMU
SCALE: 3" = 1'-0"A801
13 (MP-1) INSIDE CORNER DETAIL @ STUD
SCALE: 3" = 1'-0"A801
14 (MP-1) INSIDE CORNER DETAIL @ CMU
SCALE: 3" = 1'-0"A801
15 (MP-1) OVERLAP SEAM JOINT @ STUD
SCALE: 3" = 1'-0"A801
16 (MP-1) OVERLAP SEAM JOINT @ CMU
0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4"
0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4"
0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4"
E X
IS
T
IN
G
N E
W
EXISTING STUD WALL
EXISTING GYPSUM BOARD
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 12" O.C.
CONCEALED FASTENER
CORRUGATED
VERTICAL METAL PANEL
EXISTING SHEATHING
PREFINISHED METAL
PANEL CLOSURE TRIM
EXISTING WINDOW
WOOD BLOCKING
NOTE: EXISTING METAL TRIM
AROUND WINDOW TO REMAIN AS
CALLED OUT ON ELEVATION 2, 3
AND 4/A141, KEY NOTE 15.
METAL PANELS TO BUTT UP
AGAINST METAL TRIM.
E X
IS
T
IN
G
N E
W
EXISTING STUD WALL
EXISTING GYPSUM BOARD
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
EXISTING SHEATHING
EXISTING DOOR
EXISTING
DOOR
FRAME
SEALANT
CONCEALED FASTENER
CORRUGATED
VERTICAL METAL PANEL
PREFINISHED METAL
PANEL CLOSURE TRIM
WOOD BLOCKING
7/8" HAT CHANNEL
@ 12" O.C.
E X
IS
T
IN
G
N E
W
EXISTING CMU WALL
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 12" O.C.
EXISTING WINDOW
CONCEALED FASTENER
CORRUGATED
VERTICAL METAL PANEL
PREFINISHED METAL
PANEL CLOSURE TRIM
WOOD BLOCKING
E X
IS
T
IN
G
N E
W
EXISTING CMU WALL
FLUID APPLIED AIR BARRIER, EXTEND
INTO ROUGH OPENING AS SHOWN
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 12" O.C.
DOOR
DOOR
FRAME
SEALANT
CONCEALED FASTENER
CORRUGATED
VERTICAL METAL PANEL
PREFINISHED METAL
PANEL CLOSURE TRIM
WOOD BLOCKING
SEALANT
EXISTINGNEW
PREFINISHED METAL
PANEL CLOSURE TRIM
W/ WEEPS
EXISTING SHEATHING
EXISTING STUD WALL
EXISTING GYPSUM BOARD
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 12" O.C.
CONCEALED FASTENER
CORRUGATED
VERTICAL (OR HORIZONTAL)
METAL PANEL
EXISTING WINDOW
SEALANT
2"7/8"7/8"
SEE ELEVATIONS FOR
AREAS WITH
HORIZONTAL BAND
ABOVE WINDOW,
REFER TO 8/A802
FOR SIMILAR DETAIL
METAL PANEL TRIM CLOSURE
EXISTINGNEW
PREFINISHED METAL
PANEL CLOSURE TRIM
W/ WEEPS
EXISTING CMU WALL
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 12" O.C.
CONCEALED FASTENER
CORRUGATED
VERTICAL (OR HORIZONTAL)
METAL PANEL
EXISTING WINDOW
SEALANT
2"7/8"7/8"
METAL PANEL TRIM CLOSURE
EXISTINGNEW
PREFINISHED METAL
PANEL CLOSURE TRIM
W/ WEEPS
EXISTING SHEATHING
EXISTING STUD WALL
EXISTING GYPSUM BOARD
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 12" O.C.
CONCEALED FASTENER
CORRUGATED
VERTICAL (OR HORIZONTAL)
METAL PANEL
SEE ELEVATIONS FOR
AREAS WITH
HORIZONTAL BAND
ABOVE DOOR, REFER
TO 8/A802 FOR
SIMILAR DETAIL
SEALANT AND BACKER
ROD
2"7/8"7/8"
EXISTING DOOR FRAME
EXISTING DOOR
METAL PANEL TRIM CLOSURE
EXISTINGNEW
EXISTING CMU WALL
FLUID APPLIED AIR BARRIER,
EXTEND INTO ROUGH OPENING
AS SHOWN
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 12" O.C.
CONCEALED FASTENER
CORRUGATED
VERTICAL (OR HORIZONTAL)
METAL PANEL
DOOR
SEALANT AND BACKER
ROD
2"7/8"7/8"
SEALANT
DOOR FRAME
PREFINISHED METAL BOTTOM
CLOSURE "J" TRIM W/ WEEPS
(2) 2X4 BLOCKING
WOOD BLOCKING FOR
ATTACHMENT OF
HORIZONTAL TRIM
PITCH TOP OF HORIZONTAL
TRIM AWAY FROM BUILDING
HORIZONTAL TRIM
EXISTING SHEATHING
EXISTING STUD WALL
EXISTING GYPSUM BOARD
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 12" O.C.
CONCEALED FASTENER
CORRUGATED VERTICAL
(OR HORIZONTAL)
METAL PANEL
EXISTINGNEW
2"7/8"7/8"
PREFINISHED METAL OUTSIDE
CORNER TRIM
3"
WOOD BLOCKING
EXISTING CMU WALL
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
EXISTINGNEW
2"7/8"7/8"
PREFINISHED METAL OUTSIDE
CORNER TRIM
3"
7/8" HAT CHANNEL
@ 12" O.C.
CONCEALED FASTENER
CORRUGATED VERTICAL
(OR HORIZONTAL)
METAL PANEL
3"
WOOD BLOCKING
EXISTING STUD WALL
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
PREFINISHED METAL INSIDE
CORNER TRIM
7/8" HAT CHANNEL
@ 12" O.C.
CONCEALED FASTENER
CORRUGATED VERTICAL
(OR HORIZONTAL)
METAL PANEL
WOOD BLOCKING
/8
/8
E X
IS
T
IN
G
N E
W EXISTING SHEATHING
EXISTING GYPSUM BOARD
EXISTING CMU WALL
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
PREFINISHED METAL INSIDE
CORNER TRIM
7/8" HAT CHANNEL
@ 12" O.C.
CONCEALED FASTENER
CORRUGATED VERTICAL
(OR HORIZONTAL)
METAL PANEL
WOOD BLOCKING
/8
/8
E X
IS
T
IN
G
N E
W
2"7/8"7/8"
EXISTINGNEW
EXISTING SHEATHING
EXISTING STUD WALL
EXISTING GYPSUM BOARD
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 12" O.C.
CONCEALED FASTENER
CORRUGATED
VERTICAL (OR HORIZONTAL)
METAL PANEL
PLAN VIEW
2"7/8"7/8"
EXISTINGNEW
EXISTING CMU WALL
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 12" O.C.
CONCEALED FASTENER
CORRUGATED
VERTICAL (OR HORIZONTAL)
METAL PANEL
PLAN VIEW
2"7/8"7/8"
EXISTINGNEW
EXISTING SHEATHING
EXISTING STUD WALL
EXISTING GYPSUM BOARD
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 12" O.C.
CONCEALED FASTENER
CORRUGATED
VERTICAL (OR HORIZONTAL)
METAL PANEL
PLAN VIEW
/2
PREFINISHED METAL VERTICAL
TRANSITION TRIM
METAL PANEL TRIM CLOSURE
2"7/8"7/8"
EXISTINGNEW
EXISTING CMU WALL
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 12" O.C.
CONCEALED FASTENER
CORRUGATED
VERTICAL (OR HORIZONTAL)
METAL PANEL
PLAN VIEW
/2
PREFINISHED METAL VERTICAL
TRANSITION TRIM
METAL PANEL TRIM CLOSURE
ARCHITECTURE
ENGINEERING
INTERIOR DESIGN
STRANG, INC.
6411 MINERAL POINT ROAD
MADISON, WI 53705-4395
SHEET NAME
PROJECT TITLE
DRAWING SET
DRAWN
CHECKED
DATE
PROJECT NO.
SHEET NO.
CONSTRUCTION
DOCUMENT SET
FOR
CONSTRUCTION
TC
12/21/2016
TZ/TC
1831 E. US HIGHWAY 169
GRAND RAPIDS, MN 55744
USDA FOREST
SERVICE -
NORTHERN
RESEARCH
STATION - ROOF &
SIDING UPGRADE
2012012.04
CD
EXTERIOR
DETAILS
A802
SCALE: 3" = 1'-0"A802
1 (MP-2) WINDOW JAMB DETAIL @ STUD
SCALE: 3" = 1'-0"A802
3 (MP-2) DOOR JAMB DETAIL @ STUD
SCALE: 3" = 1'-0"A802
2 (MP-2) WINDOW JAMB DETAIL @ CMU
SCALE: 3" = 1'-0"A802
4 (MP-2) DOOR JAMB DETAIL @ CMU
SCALE: 3" = 1'-0"A802
5 (MP-2) WINDOW HEAD DETAIL @ STUD
SCALE: 3" = 1'-0"A802
6 (MP-2) WINDOW HEAD DETAIL @ CMU
SCALE: 3" = 1'-0"A802
7 (MP-2) DOOR HEAD DETAIL @ STUD
SCALE: 3" = 1'-0"A802
8 (MP-2) DOOR HEAD DETAIL @ CMU
SCALE: 3" = 1'-0"A802
11 (MP-2) OUTSIDE CORNER DETAIL @ STUD
SCALE: 3" = 1'-0"A802
12 (MP-2) OUTSIDE CORNER DETAIL @ CMU
SCALE: 3" = 1'-0"A802
13 (MP-2) INSIDE CORNER DETAIL @ STUD
SCALE: 3" = 1'-0"A802
14 (MP-2) INSIDE CORNER DETAIL @ CMU
SCALE: 3" = 1'-0"A802
9 (MP-2) SEAM DETAIL @ STUD
SCALE: 3" = 1'-0"A802
10 (MP-2) SEAM DETAIL @ CMU
SCALE: 3" = 1'-0"A802
15 (MP-2) VERTICAL TRANSITION DETAIL @ STUD
SCALE: 3" = 1'-0"A802
16 (MP-2) VERTICAL TRANSITION DETAIL @ CMU
0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4"
0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4"
0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4"
NOTE: DETAILS SHOWN ON SHEET
A802 SHOW VERTICAL METAL PANEL
APPLICATION, SEE ELEVATIONS ON
SHEET A401 FOR VERTICAL OR
HORIZONTAL METAL PANEL
APPLICATION TO BE INSTALLED
EXISTING SHEATHING
EXISTING STUD WALL
EXISTING GYPSUM BOARD
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
2"
EXISTING NEW
LATH
MORTAR SCRATCH COAT
MORTAR SETTING BED
ADHERED MANUFACTURED
STONE VENEER
WEATHER RESISTIVE BARRIER
EXISTING SHEATHING
EXISTING STUD WALL
EXISTING GYPSUM BOARD
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
PREFINISHED METAL BOTTOM
CLOSURE TRIM W/ WEEPS
AND BUG SCREEN, LAP
FOUNDATION
SEALANT
GRADE
2"
EXISTING NEW
LATH
MORTAR SCRATCH COAT
MORTAR SETTING BED
ADHERED MANUFACTURED
STONE VENEER
WEATHER RESISTIVE BARRIER
EXISTING SHEATHING
EXISTING STUD WALL
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
EXISTING WINDOW
PREFINISHED METAL FLASHING
(2) 2X4 BLOCKING
PITCH TOP OF HORIZONTAL
TRIM AWAY FROM BUILDING
SEALANT
EXISTING NEW
LATH
MORTAR SCRATCH COAT
MORTAR SETTING BED
ADHERED MANUFACTURED
STONE VENEER
SEALANT, DO NOT COVER UP
WINDOW WEEP HOLES
WEATHER RESISTIVE BARRIER
E X
IS
T
IN
G
N E
W
EXISTING STUD WALL
EXISTING GYPSUM BOARD
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
EXISTING SHEATHING
EXISTING WINDOW
SEALANT AND BACKER ROD
LATH
MORTAR SCRATCH COAT
MORTAR SETTING BED
ADHERED MANUFACTURED
STONE VENEER
WEATHER RESISTIVE BARRIER
EXISTING SHEATHING
EXISTING STUD WALL
EXISTING GYPSUM BOARD
FLUID APPLIED
AIR BARRIER
2" RIGID
INSULATION
EXISTINGNEW
2"
LATH
MORTAR SCRATCH COAT
MORTAR SETTING BED
ADHERED MANUFACTURED
STONE VENEER
/4
7 1/4".
2X6 BLOCKING
BLOCKING
PREFINISHED
METAL VERTICAL
TRIM
SEALANT AND
BACKER ROD
2X4 BLOCKING
RUN
HORIZONTALLY
24" O.C. FOR
ATTACHMENT TO
EXISTING STUDS
(DASHED LINES)
TREATED PLYWOOD COVER AT
BASE, SET OFF GROUND 2"
WEATHER
RESISTIVE
BARRIER
EXISTING STUD WALL
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
E X
IS
T
IN
G
N E
W
EXISTING SHEATHING
EXISTING GYPSUM BOARD
LATH
MORTAR SCRATCH COAT
MORTAR SETTING BED
ADHERED MANUFACTURED
STONE VENEER
7/8" HAT CHANNEL
@ 16" O.C.
CONCEALED FASTENER
CORRUGATED HORIZONTAL
METAL PANEL
SEALANT W/ BACKER ROD
/8
/8
WEATHER RESISTIVE BARRIER
E X
IS
T
IN
G
N E
W
EXISTING STUD WALL
EXISTING GYPSUM BOARD
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
EXISTING SHEATHING
DOOR
DOOR
FRAME
SEALANT AND BACKER ROD
SEALANT
LATH
MORTAR SCRATCH COAT
MORTAR SETTING BED
ADHERED MANUFACTURED
STONE VENEER
WEATHER RESISTIVE BARRIER
ARCHITECTURE
ENGINEERING
INTERIOR DESIGN
STRANG, INC.
6411 MINERAL POINT ROAD
MADISON, WI 53705-4395
SHEET NAME
PROJECT TITLE
DRAWING SET
DRAWN
CHECKED
DATE
PROJECT NO.
SHEET NO.
CONSTRUCTION
DOCUMENT SET
FOR
CONSTRUCTION
TC
12/21/2016
TZ/TC
1831 E. US HIGHWAY 169
GRAND RAPIDS, MN 55744
USDA FOREST
SERVICE -
NORTHERN
RESEARCH
STATION - ROOF &
SIDING UPGRADE
2012012.04
CD
EXTERIOR
DETAILS
A803
SCALE: 3" = 1'-0"A803
1 CULTERED STONE SECTION @ STUD
SCALE: 3" = 1'-0"A803
2 CULTURED STONE BASE DETAIL @ STUD
SCALE: 3" = 1'-0"A803
3 CULTURED STONE WINDOW SILL @ STUD
SCALE: 3" = 1'-0"A803
4 CULTURED STONE WINDOW JAMB @ STUD
SCALE: 3" = 1'-0"A803
5 CULTURED STONE OUTSIDE CORNER @ STUD
SCALE: 3" = 1'-0"A803
6 CULTURED STONE INSIDE CORNER @ STUD
0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4"
0' 6"2" 4"
SCALE: 3" = 1'-0"A803
7 CULTURED STONE DOOR JAMB @ STUD
0' 6"2" 4"
7/8"
EXISTING CMU WALL
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 16" O.C.
CONCEALED FASTENER
CORRUGATED HORIZONTAL
METAL PANEL
5/8" PLYWOOD
PLAN VIEW
2X4 WOOD BLOCKING
PREFINISHED METAL
VERTICAL TRIM
NEW
2"7/8"
3 1/4"
METAL PANEL TRIM CLOSURE
PREFINISHED METAL PANEL
CLOSURE TRIM
TREATED PLYWOOD
COVER AT BASE, SET
OFF GROUND 2"
SEALANT AND BACKER
ROD
7/8"
EXISTINGNEW
EXISTING STUD WALL
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 16" O.C.
CONCEALED FASTENER
CORRUGATED HORIZONTAL
METAL PANEL
5/8" PLYWOOD
PLAN VIEW
2X4 WOOD BLOCKING
PREFINISHED METAL
VERTICAL TRIM
EXISTING SHEATHING
EXISTING GYPSUM BOARD
2"7/8"
3 1/4"
METAL PANEL TRIM CLOSURE
PREFINISHED METAL PANEL
CLOSURE TRIM
TREATED PLYWOOD
COVER AT BASE, SET
OFF GROUND 2"
SEALANT AND BACKER
ROD
2"
EXISTINGNEW
EXISTING SHEATHING
EXISTING STUD WALL
EXISTING GYPSUM BOARD
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 12" O.C.
CONCEALED FASTENER
CORRUGATED
HORIZONTAL
METAL PANEL
(2) 2X4 BLOCKING
WOOD BLOCKING FOR
ATTACHMENT OF PREFINISHED
METAL HORIZONTAL TRIM
PITCH TOP OF HORIZONTAL
TRIM AWAY FROM BUILDING
SEALANT
SEALANT
PREFINISHED METAL
HORIZONTAL TRIM
CONCEALED FASTENER
CORRUGATED
HORIZONTAL
METAL PANEL
7/8"7/8"
1 1/4"
2"
EXISTINGNEW
EXISTING CMU WALL
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 12" O.C.
CONCEALED FASTENER
CORRUGATED
HORIZONTAL
METAL PANEL
(2) 2X4 BLOCKING
WOOD BLOCKING FOR
ATTACHMENT OF PREFINISHED
METAL HORIZONTAL TRIM
PITCH TOP OF HORIZONTAL
TRIM AWAY FROM BUILDING
SEALANT
SEALANT
PREFINISHED METAL
HORIZONTAL TRIM
CONCEALED FASTENER
CORRUGATED
HORIZONTAL
METAL PANEL
7/8"7/8"
1 1/4"
2"
EXISTINGNEW
EXISTING SHEATHING
EXISTING STUD WALL
EXISTING GYPSUM BOARD
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 12" O.C.
CONCEALED FASTENER
CORRUGATED
VERTICAL METAL PANEL
(2) 2X4 BLOCKING
WOOD BLOCKING FOR
ATTACHMENT OF PREFINISHED
METAL HORIZONTAL TRIM
PITCH TOP OF HORIZONTAL
TRIM AWAY FROM BUILDING
SEALANT
PREFINISHED METAL
HORIZONTAL TRIM
CONCEALED FASTENER
CORRUGATED
HORIZONTAL
METAL PANEL
7/8"7/8"
PREFINISHED METAL BOTTOM
CLOSURE "J" TRIM W/ WEEPS
1 1/4"
2"
EXISTINGNEW
EXISTING CMU WALL
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 12" O.C.
CONCEALED FASTENER
CORRUGATED
VERTICAL METAL PANEL
(2) 2X4 BLOCKING
WOOD BLOCKING FOR
ATTACHMENT OF PREFINISHED
METAL HORIZONTAL TRIM
PITCH TOP OF HORIZONTAL
TRIM AWAY FROM BUILDING
SEALANT
PREFINISHED METAL
HORIZONTAL TRIM
CONCEALED FASTENER
CORRUGATED
HORIZONTAL
METAL PANEL
7/8"7/8"
PREFINISHED METAL BOTTOM
CLOSURE "J" TRIM W/ WEEPS
1 1/4"
EXISTING EQUIPMENT
EXISTING EQUIPMENT CURB
COUNTERFLASHING FASTENED
APPROX. 18" O.C. - SUPPLIED
AND INSTALLED BY SHEET
METAL CONTRACTOR
FASTENERS APPROX. 8" O.C.
MEMBRANE FLASHING STRIP,
OVERLAP BASE PER ROOFING
MANUFACTURER'S
REQUIREMENTS
FULLY ADHERED EPDM
MEMBRANE ROOFING
2"
NOM.
E X
IS
T
IN
G
WOOD BLOCKING
PIPE
LAP SEALANT
ENTIRE PERIMETER
PREFABRICATED MOULDED
PLASTIC PIPE FLASHING
FULLY ADHERED EPDM
MEMBRANE ROOFING
ROOF INSULATION
(DEPTH VARIES)
ROOF STRUCTURE
LAP SEALANT SEAM EDGE
TREATMENT ENTIRE
PERIMETER
STAINLESS STEEL
CLAMPING RING
PIPE
LAP TEMPERATURE APPROPRIATE
SEALANT ENTIRE PERIMETER
FLASHING MEMBRANE
(ADHERED TO CURB)
FULLY ADHERED EPDM
MEMBRANE ROOFING
ROOF INSULATION
(DEPTH VARIES)
ROOF STRUCTURE
LAP SEALANT SEAM EDGE
TREATMENT ENTIRE
PERIMETER
STAINLESS STEEL
CLAMPING RING
FILL VOID WITH
INSULATION
F L A
S H
IN
G
H T
N O
M
WOOD BLOCKING
REMOVABLE SHEET METAL
COUNTERFLASHING
HIGH-DOMED, CAPPED
GASKETED FASTENERS
SHEET METAL UMBRELLA
PREFINISHED METAL
CAP
PREFINISHED METAL
TRIM ON FASCIA
WALL SYSTEM
* METAL PANEL (MP-2)
* 7/8" HAT CHANNEL
* 2" RIGID INSULATION
* FLUID APPLIED AIR
VAPOR BARRIER
TOP OF ROOF
TOP OF SIDE ROOF
WALL SYSTEM
* METAL PANEL (MP-2)
* 7/8" HAT CHANNEL
* 2" RIGID INSULATION
* FLUID APPLIED AIR
VAPOR BARRIER
PREFINISHED METAL
CAP
PREFINISHED METAL
TRIM ON FASCIA
TOP OF SIDE ROOF
PREFINISHED METAL
PANEL CLOSURE TRIM
W/ WEEPS
EXISTING STRUCTURE
FLUID APPLIED AIR BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 12" O.C.
CONCEALED FASTENER
CORRUGATED
VERTICAL METAL PANEL
METAL PANEL TRIM CLOSURE
FULLY ADHERED EPDM
MEMBRANE ROOFING, EXTEND
UP WALL AND FASTEN TOP WITH
ALUMINUM COMPRESSION BAR
12" O.C.
4" MINIMUM RIGID
INSULATION
SECTION
SECTION CUT,
SEE SECTION
DRAWING BELOW
COUNTERFLASHING
SEALANT
REINFORCE PERIMETER
SECUREMENT STRIP
WITH FASTENER
PLATES 12" O.C.
EXISTING METAL
FLASHING
EXISTING AIR
HANDLING UNIT
CUT EXISTING EPDM
MEMBRANE, TUCK NEW
EPDM MEMBRANE UNDER
OLD, PROVIDE SEALANT
NEW FULLY ADHERED
EPDM MEMBRANE
ROOFING
NEW FULLY ADHERED
EPDM MEMBRANE
ROOFING
REMOVE EXISTING
SKYLIGHT AND
FLASHING, INSTALL
EPDM MEMBRANE ON
TOP OF CURB,
REINSTALL SKYLIGHT
AND NEW FLASHING
PREFINISHED
METAL CAP
W/ DRIP EDGE
2X BLOCKING
FULLY ADHERED EPDM
MEMBRANE ROOFING,
EXTEND UP PARAPET
WALL UNDER FLASHING
EXISTING PARPET WALL
4" MINIMUM RIGID
INSULATION
EXISTING STRUCTURE
PROVIDE 4" MINIMUM
SPRAY FOAM IN CAVITY
SPACE, PATCH
SHEATHING
EXISTING ROOFING
SLOPE
PREFINISHED METAL CAP
BEYOND
FULLY ADHERED EPDM
MEMBRANE ROOFING
WRAPPED OVER
SCUPPER FLASHING
EXISTING CMU WALL
ALUMINUM SCUPPER,
EXTENDS UP SIDE WALLS
AND UNDER METAL CAP
4" MINIMUM RIGID INSULATION
TAPER INSULATION DOWN TO
SCUPPER
EXISTING ROOF STRUCTURE
2x4 BLOCKING
FLUID APPLIED AIR
BARRIER
2" RIGID INSULATION
7/8" HAT CHANNEL
@ 12" O.C.
CONCEALED FASTENER
CORRUGATED
VERTICAL (OR HORIZONTAL)
METAL PANEL
2"
7/8" 7/8"
METAL PANEL TRIM CLOSURE
PREFINISHED METAL
PANEL CLOSURE TRIM
EXISTINGNEW
DOWNSPOUT
PREFINISHED
METAL CAP
W/ DRIP EDGE
2X BLOCKING
FULLY ADHERED EPDM
MEMBRANE ROOFING,
EXTEND UP PARAPET
WALL UNDER FLASHING
EXISTING PARPET WALL
4" MINIMUM RIGID
INSULATION
EXISTING STRUCTURE
2"RIGID INSULATION
1/2" PLYWOOD
PROVIDE SPRAY FOAM IN
CAVITY SPACE, PATCH
SHEATHING
SLOPE
ARCHITECTURE
ENGINEERING
INTERIOR DESIGN
STRANG, INC.
6411 MINERAL POINT ROAD
MADISON, WI 53705-4395
SHEET NAME
PROJECT TITLE
DRAWING SET
DRAWN
CHECKED
DATE
PROJECT NO.
SHEET NO.
CONSTRUCTION
DOCUMENT SET
FOR
CONSTRUCTION
TC
12/21/2016
TZ/TC
1831 E. US HIGHWAY 169
GRAND RAPIDS, MN 55744
USDA FOREST
SERVICE -
NORTHERN
RESEARCH
STATION - ROOF &
SIDING UPGRADE
2012012.04
CD
EXTERIOR
DETAILS
A804
SCALE: 3" = 1'-0"A804
2 VERTICAL POST DETAIL @ CMU
SCALE: 3" = 1'-0"A804
1 VERTICAL POST DETAIL @ STUD
SCALE: 3" = 1'-0"A804
3 UPPER HORIZONTAL BAND DETAIL @ STUD
SCALE: 3" = 1'-0"A804
4 UPPER HORIZONTAL BAND DETAIL @ CMU
SCALE: 3" = 1'-0"A804
5 LOWER HORIZONTAL BAND DETAIL @ STUD
SCALE: 3" = 1'-0"A804
6 LOWER HORIZONTAL DETAIL @ CMU
0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4"
SCALE: 1 1/2" = 1'-0"A804
7 EXHAUST HOOD CURB DETAIL
SCALE: 1 1/2" = 1'-0"A804
10 ROOF PENETRATION COLD PIPE
SCALE: 1 1/2" = 1'-0"A804
11 ROOF PENETRATION HOT PIPE
0' 1'4" 8" 0' 1'4" 8" 0' 1'4" 8" 0' 1'4" 8"
SCALE: 3/4" = 1'-0"A804
13 CLERESTORY ROOF DETAIL 2
SCALE: 3/4" = 1'-0"A804
12 CLERESTORY ROOF DETAIL 1
0' 1'4" 8"0' 1'4" 8"
SCALE: 3" = 1'-0"A804
8 AIR HANDLING UNIT CURB DETAILS
SCALE: 3" = 1'-0"A804
9 SKYLIGHT SECTION
SCALE: 3" = 1'-0"A804
14 PARAPET DETAIL @ ROOF
0' 1'4" 8"
0' 6"2" 4"
SCALE: 3" = 1'-0"A804
15 SCUPPER DETAIL
0' 6"2" 4"
SCALE: 3" =…
This is the start of the file's text. The full file is on GovTribe.