d_Siding_Upgrade_Construction_Requisition_Dwgs.pdf

PDF 15 MB Posted

Attached to
Facility Infrastructure Inprovements Federal contract opportunity
Solicitation number
1263PX19Q0065
Issued by
Department of Agriculture Forest Service Research Service Northern Research Station

About this file

Drawings for the siding upgrade

View the file

Other files for this federal contract opportunity

Other files attached to Facility Infrastructure Inprovements, newest first.
File Type Posted
E201_Ammended_07302019.pdf PDF
M101_Ammended_07292019.pdf PDF
Amendment-003-0065.pdf PDF
A501_Ammended_07292019.pdf PDF
dwg-07292019.zip ZIP file
GR_Sign_in.pdf PDF
SF-30_GR-001.pdf PDF
SF-30-001.pdf PDF
ure_Renovations_Construction_Requisition_Specs.pdf PDF
RFP-Grand_Rapids_Infrastructure_Improvements.doc DOC document
ture_Renovations_Construction_Requisition_Dwgs.pdf PDF
d_Siding_Upgrade_Construction_Requisition_Dwgs.pdf PDF
Siding_Upgrade_Construction_Requisition_Specs.pdf PDF
ure_Renovations_Construction_Requisition_Specs.pdf PDF
Siding_Upgrade_Construction_Requisition_Specs.pdf PDF
ure_Renovations_Construction_Requisition_Specs.pdf PDF
ure_Renovations_Construction_Requisition_Specs.pdf PDF
RFP-Grand_Rapids_Infrastructure_Improvements.doc DOC document
Show all 18

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DETAIL REFERENCE

Detail Number

Sheet Number

EXTERIOR ELEVATION

Exterior Elevation Number

Sheet Number

ROOM NAME/

ROOM NUMBER

SPECIFIC ELEVATION NOTE

SPECIFIC PLAN NOTE

REVISION

(Cloud Around Revision)

ROOM NAME

RM ##

SPECIFIC DEMOLITION NOTE#

A501

WALL SECTION CALLOUT

A801

DETAIL CALLOUT

A801

DETAIL CALLOUT

SHEET NAME

SHEET NO.

DATE

DRAWING SET

ARCHITECTURE

ENGINEERING

INTERIOR DESIGN

STRANG, INC.

6411 MINERAL POINT ROAD

MADISON, WI 53705-4395

ARCHITECTURAL

STRANG, INC.

DESIGN TEAM PROJECT IMAGE

SHEET INDEXSTAMPS

SITE LOCATION MAP

SYMBOL LEGEND

ELECTRICAL NOTES

TITLE SHEET

T001

12/21/2016

CD

1831 E. US HIGHWAY 169

GRAND RAPIDS, MN 55744 PROJECT NO. : 2012012.04

GENERAL

T001 TITLE SHEET

ARCHITECTURAL

A101 DEMOLITION FIRST FLOOR PLAN

A102 DEMOLITION ROOF PLAN

A141 DEMOLITION EXTERIOR ELEVATIONS

A201 FIRST FLOOR PLAN

A202 ROOF PLAN

A401 EXTERIOR ELEVATIONS

A501 WALL SECTIONS

A801 EXTERIOR DETAILS

A802 EXTERIOR DETAILS

A803 EXTERIOR DETAILS

A804 EXTERIOR DETAILS

A805 EXTERIOR DETAILS

A806 EXTERIOR DETAILS

- CONSTRUCTION DOCUMENT PACKAGE

SITE

USDA FOREST SERVICE

NORTHERN RESEARCH STATION

FORESTRY SCIENCES LABORATORY GRAND RAPIDS

ROOF & SIDING UPGRADE

FORESTRY SCIENCES

LABORATORY

GRAND RAPIDS

ARCHITECTURAL DESIGN

GENERAL: ELECTRICAL COMPONENTS, DEVICES AND ACCESSORIES SHALL BE LISTED AND LABELED AS DEFINED IN NFPA 70 ARTICLE 100. SUBMIT PRODUCT

DATA AND SAMPEL FOR EACH TYPE OF PRODUCT.

PRODUCTS: MANUFACTURERS SHALL BE ONE OF THE FOLLOWING: HUBBELL INCORPORATED; WIRING DEVICES-KELLEMS; LEVITON MFG. COMPANY INC.; PASS &

SEYMOUR/LEGRAND; WIRING DEVICES DIV.

RECEPTACLES: GFCI RECEPTACLES SHALL BE STRAIGHT BLADE, NON-FEED-THROUGH TYPE, HEAVY-DUTY GRADE, 5-20R DUPLEX RECEPTACLE. DESIGN UNITS FOR INSTALLATION IN A 2-3/4-INCH DEEP OUTLET BOX WITHOUT AN ADAPTER. VERIFY ASSEMBLY SIZE WITH WALL THICKNESS.

WALL PLATES: MATERIAL FOR OUTDOOR WET LOCATIONS SHALL BE CAST ALUMINUM BUBBLE TYPE COVER, AND LISTED AND LABELED FOR USE IN "WET

LOCATIONS" AND SHALL BE WEATHERPROOF TYPE WITH THE ATTACHMENT PLUG CAP INSERTED.

EXECUTION: INSTALL DEVICES AND ASSEMBLIES LEVEL, PLUMB, AND SQUARE WITH BUILDING LINES. DEVICES SHALL BE MOUNTED FLUSH, WITH LONG DIMENSION VERTICAL, AND WITH GROUNDING TERMINAL OF RECEPTACLES ON TOP. REMOVE WALL PLATES AND PROTECT DEVICES AND ASSEMBLIES DURING

SURFACE PAINTING BY OTHER CONTRACTORS.

A141

A141

A141

A141

A141

CONFERENCE

ENTRY

OFFICE/LAB

GIS

SHOP/GARAGE

STORAGE

HEADHOUSE

ARCHIVE

W O

O D

S

I D

I N

G

M E

T A

L

S

I D

I N

G

M E

T A

L

S

I D

I N

G

M E

T A

L

S

I D

I N

G

WOOD

SIDING

WOOD

SIDING

METAL SIDING

W O

O D

S

I D

I N

G

A141

A141

A141

A141

A141

A141

13 13 13

ARCHITECTURE

ENGINEERING

INTERIOR DESIGN

STRANG, INC.

6411 MINERAL POINT ROAD

MADISON, WI 53705-4395

SHEET NAME

PROJECT TITLE

DRAWING SET

DRAWN

CHECKED

DATE

PROJECT NO.

SHEET NO.

CONSTRUCTION

DOCUMENT SET

FOR

CONSTRUCTION

TC

12/21/2016

AH/TZ

1831 E. US HIGHWAY 169

GRAND RAPIDS, MN 55744

USDA FOREST

SERVICE -

NORTHERN

RESEARCH

STATION - ROOF &

SIDING UPGRADE

2012012.04

CD

DEMOLITION FIRST

FLOOR PLAN

A101

GENERAL DEMOLITION PLAN NOTES

1 MAINTAIN CONTINUOUS UTILITY SERVICE TO ALL

SPACES IN THE BUILDING. COORDINATE WITH

OWNER ANY DISRUPTIONS WHICH MAY BE

REQUIRED TO COMPLETE THE WORK.

2 PROTECT IN PLACE DURING ENTIRE

CONSTRUCTION PROCESS: DOORS, WINDOWS,

SURFACES AND ITEMS TO REMAIN.

3 COORDINATE WITH OWNER THE AVAILABILITY OF

AREAS REQUIRING DEMOLITION. SEQUENCE WORK

ACCORDINGLY AND COORDINATE W/ ALL TRADES.

4 THE CONTRACTOR SHALL PATCH, PREPARE,

REPAIR AND/OR RESTORE SURFACES SCHEDULED

TO REMAIN INTACT THAT ARE DAMAGED AS A

RESULT OF DEMOLITION WORK.

5 DEMOLITION PLANS ARE NOT NECESSARILY

INCLUSIVE OF ALL ITEMS NEEDING REMOVAL.

COORDINATE WITH ALL OTHER DRAWINGS AND

FIELD VERIFY EXISTING CONDITIONS.

6 COORDINATE DEMOLITION DIMENSIONS ON THIS

PLAN WITH NEW WORK PLANS AND EXISTING

CONDITIONS.

7 MAINTAIN ALL EXIT DOORS IN UNOBSTRUCTED

OPERABLE CONDITION WITH SAFE PASSAGEWAY

FROM BUILDING. COORDINATE WITH THE LOCAL

FIRE MARSHAL AND BUILDING INSPECTOR.

8 PROVIDE AND MAINTAIN BARRICADES, GATES, OR

OTHER MEANS OF MAINTAINING PUBLIC SAFETY AT

ALL AREAS OF CONSTRUCTION OR DEMOLITION.

9 SEE NEW WORK ELEVATIONS AND DETAILS FOR

ADDITIONAL SELECTIVE DEMOLITION WORK.

10 WORK WHICH RENDERS THE EXISTING BUILDING

NON-WEATHER TIGHT SHALL BE FITTED TO

PROVIDE WEATHER TIGHT STRUCTURE PRIOR TO

NEW WORK BEING INSTALLED.

11 ALL EXISTING PENETRATIONS AND ATTACHMENTS

INCLUDING LIGHTS AT SOFFITS AND ROOFS TO BE

MODIFIED AS NECESSARY TO ACCOMMODATE NEW

SOFFIT AND ROOF ASSEMBLY.

SPECIFIC DEMOLITION PLAN NOTES

1 DORMER ABOVE FLOOR PLAN CUT LEVEL FOR

REFERENCE.

2 DASHED LINES REPRESENT AREAS TO BE

DEMOLISHED, SEE NOTES ON PLAN FOR

ADDITIONAL INFORMATION.

3 REMOVE EXTERIOR ASSEMBLY TO EXISTING

SHEATHING OR CONCRETE MASONRY UNITS (CMU).

4 OFFICE/LAB, SHOP/GARAGE, AND HEADHOUSE

BUILDINGS ASSUMED TO HAVE LEAD WOOD SIDING,

PROVIDE LEAD SAFE DEMOLITION OF MATERIAL.

5 REMOVE WOOD SIDING.

6 REMOVE METAL SIDING.

7 REMOVE METAL SIDING AND 2" RIGID INSULATION.

8 EXISTING DOOR TO REMAIN UNLESS NOTED

OTHERWISE, TYPICAL.

9 EXISTING WINDOW TO REMAIN UNLESS NOTED

OTHERWISE, TYPICAL.

10 EXISTING OVERHEAD DOOR TO REMAIN, TYPICAL.

11 EXISTING EXPOSED CONCRETE MASONRY UNITS

(CMU) TO REMAIN.

12 REMOVE DOOR AND FRAME.

13 REMOVE WINDOW.

SCALE: 1/8" = 1'-0"

A101

FIRST FLOOR PLAN

0' 4' 8'

NORTH

REVISED 03/11/2019

REMOVE

FULLY ADHERED EPDM

REMOVE BALLASTED EPDM

FULLY ADHERED EPDM TO REMAIN

FULLY ADHERED EPDM TO REMAIN

FULLY ADHERED EPDM TO REMAIN

REMOVE BALLASTED EPDM

REMOVE BALLASTED EPDM

REMOVE BALLASTED EPDM

REMOVE BALLASTED EPDM

REMOVE BALLASTED EPDM

REMOVE

FULLY ADHERED EPDM

FULLY ADHERED EPDM TO REMAIN

ROOF SLOPE

ROOF SLOPE

ROOF SLOPE

ROOF SLOPE ROOF SLOPE

ROOF SLOPE

ROOF SLOPE

ROOF SLOPE

3 17

ARCHITECTURE

ENGINEERING

INTERIOR DESIGN

STRANG, INC.

6411 MINERAL POINT ROAD

MADISON, WI 53705-4395

SHEET NAME

PROJECT TITLE

DRAWING SET

DRAWN

CHECKED

DATE

PROJECT NO.

SHEET NO.

CONSTRUCTION

DOCUMENT SET

FOR

CONSTRUCTION

TC

12/21/2016

AH/TZ

1831 E. US HIGHWAY 169

GRAND RAPIDS, MN 55744

USDA FOREST

SERVICE -

NORTHERN

RESEARCH

STATION - ROOF &

SIDING UPGRADE

2012012.04

CD

DEMOLITION ROOF

PLAN

A102

SCALE: 1/8" = 1'-0"

A102

ROOF PLAN

0' 4' 8'

GENERAL DEMOLITION PLAN NOTES

1 MAINTAIN CONTINUOUS UTILITY SERVICE TO ALL

SPACES IN THE BUILDING. COORDINATE WITH

OWNER ANY DISRUPTIONS WHICH MAY BE

REQUIRED TO COMPLETE THE WORK.

2 PROTECT IN PLACE DURING ENTIRE

CONSTRUCTION PROCESS: DOORS, WINDOWS,

SURFACES AND ITEMS TO REMAIN.

3 COORDINATE WITH OWNER THE AVAILABILITY OF

AREAS REQUIRING DEMOLITION. SEQUENCE WORK

ACCORDINGLY AND COORDINATE W/ ALL TRADES.

4 THE CONTRACTOR SHALL PATCH, PREPARE,

REPAIR AND/OR RESTORE SURFACES SCHEDULED

TO REMAIN INTACT THAT ARE DAMAGED AS A

RESULT OF DEMOLITION WORK.

5 DEMOLITION PLANS ARE NOT NECESSARILY

INCLUSIVE OF ALL ITEMS NEEDING REMOVAL.

COORDINATE WITH ALL OTHER DRAWINGS AND

FIELD VERIFY EXISTING CONDITIONS.

6 COORDINATE DEMOLITION DIMENSIONS ON THIS

PLAN WITH NEW WORK PLANS AND EXISTING

CONDITIONS.

7 MAINTAIN ALL EXIT DOORS IN UNOBSTRUCTED

OPERABLE CONDITION WITH SAFE PASSAGEWAY

FROM BUILDING. COORDINATE WITH THE LOCAL

FIRE MARSHAL AND BUILDING INSPECTOR.

8 PROVIDE AND MAINTAIN BARRICADES, GATES, OR

OTHER MEANS OF MAINTAINING PUBLIC SAFETY AT

ALL AREAS OF CONSTRUCTION OR DEMOLITION.

9 SEE NEW WORK ELEVATIONS AND DETAILS FOR

ADDITIONAL SELECTIVE DEMOLITION WORK.

10 WORK WHICH RENDERS THE EXISTING BUILDING

NON-WEATHER TIGHT SHALL BE FITTED TO

PROVIDE WEATHER TIGHT STRUCTURE PRIOR TO

NEW WORK BEING INSTALLED.

11 ALL EXISTING PENETRATIONS AND ATTACHMENTS

INCLUDING LIGHTS AT SOFFITS AND ROOFS TO BE

MODIFIED AS NECESSARY TO ACCOMMODATE NEW

SOFFIT AND ROOF ASSEMBLY.

SPECIFIC DEMOLITION ROOF PLAN NOTES

1 BASE BID - REMOVE ROOF ASSEMBLY TO EXISTING

RIGID INSULATION. ADD-ALT: REMOVE ROOF

ASSEMBLY TO EXISTING SHEATHING, RIGID

INSULATION TO BE REMOVED.

2 REMOVE FASCIA AND RAKE TRIM FINISH, TYPICAL

AROUND BUILDING.

3 EXISTING EXHAUST HOOD CURB TO REMAIN.

4 EXISTING ROOF PENETRATION.

5 REMOVE SCUPPER.

6 EXISTING SKYLIGHT CURB TO REMAIN.

7 REMOVE DOWNSPOUT.

8 EXISTING OVERHANG.

9 REMOVE SOFFIT VENT.

10 EXISTING AIR HANDLING UNIT CURB TO REMAIN.

11 REMOVE ROOF MOUNTED ANTENNA, PATCH AND

REPAIR PENETRATIONS.

12 EXISTING RECESSED LIGHT FIXTURE UNDER

OVERHANG.

14 EXISTING ROOF VALLEY.

15 EXISTING ROOF RIDGE.

16 EXISTING PARAPET.

17 REMOVE PAD FOR INSTALATION OF NEW

MECHANICAL CURB.

NORTH

FIRST FLOOR

100' - 0"

REMOVE WOOD SIDING, TYPICAL

REMOVE FASCIA TRIM, TYPICAL

REMOVE RAKE TRIM, TYPICAL EXISTING EXPOSED

CONCRETE MASONRY

UNITS (CMU) TO REMAIN

EXISTING EXPOSED

CONCRETE MASONRY

UNITS (CMU) TO REMAIN

EXISTING OVERHEAD DOOR TO

REMAIN, TYPICAL

8 6 6

55 5

2219 19

18181817

FIRST FLOOR

100' - 0"

REMOVE WOOD SIDING, TYPICAL

REMOVE FASCIA TRIM, TYPICAL

REMOVE BALLASTED EPDM

ROOF, TYPICAL

EXISTING WINDOW TO

REMAIN, PROTECT

WINDOW TRIM DURING

CONSTRUCTION, TYPICAL

TYPICAL BETWEEN

CLERESTORY WINDOWS

15 15 15 15

FIRST FLOOR

100' - 0"

REMOVE WOOD SIDING, TYPICAL REMOVE FASCIA TRIM, TYPICAL

REMOVE RAKE TRIM, TYPICAL REMOVE BALLASTED EPDM

ROOF, TYPICAL

103 1111 88 812 13

TYPICAL

HIDDEN PORTION

OF ELEVATION,

SEE ABOVE

17 18

EXISTING MAN DOOR TO

REMAIN, TYPICAL

TYPICAL BETWEEN

CLERESTORY WINDOWS

8320 20

23 24

FIRST FLOOR

100' - 0"

REMOVE WOOD SIDING, TYPICAL

REMOVE FASCIA TRIM, TYPICALREMOVE RAKE TRIM, TYPICAL

REMOVE METAL SIDING, TYPICAL

REMOVE BALLASTED EPDM

ROOF, TYPICAL

6 6

17 20 20

4 8

FIRST FLOOR

100' - 0"

REMOVE WOOD SIDING, TYPICAL

REMOVE METAL SIDING, TYPICAL

REMOVE METAL SIDING, TYPICAL

REMOVE FASCIA TRIM, TYPICAL

FIRST FLOOR

100' - 0"

REMOVE WOOD SIDING, TYPICAL

REMOVE FASCIA

TRIM, TYPICAL

REMOVE METAL SIDING, TYPICAL

FIRST FLOOR

100' - 0"

REMOVE WOOD SIDING, TYPICAL

REMOVE FASCIA TRIM, TYPICAL

1620 20 20 20

FIRST FLOOR

100' - 0"

REMOVE METAL SIDING, TYPICAL

FIRST FLOOR

100' - 0"

REMOVE WOOD

SIDING, TYPICAL

REMOVE FASCIA

TRIM, TYPICAL

FIRST FLOOR

100' - 0"

REMOVE WOOD

SIDING, TYPICAL

FIRST FLOOR

100' - 0"

REMOVE WOOD

SIDING, TYPICAL

REMOVE RAKE

TRIM, TYPICAL

FIRST FLOOR

100' - 0"

REMOVE WOOD

SIDING, TYPICAL

REMOVE FASCIA

TRIM, TYPICAL

FIRST FLOOR

100' - 0"

REMOVE WOOD

SIDING, TYPICAL

REMOVE RAKE

TRIM, TYPICAL

FIRST FLOOR

100' - 0"

REMOVE WOOD

SIDING, TYPICAL

REMOVE FASCIA

TRIM, TYPICAL

FIRST FLOOR

100' - 0"

REMOVE FASCIA

TRIM, TYPICAL

EXISTING EXPOSED

CONCRETE

MASONRY UNITS

(CMU) TO REMAIN

ARCHITECTURE

ENGINEERING

INTERIOR DESIGN

STRANG, INC.

6411 MINERAL POINT ROAD

MADISON, WI 53705-4395

SHEET NAME

PROJECT TITLE

DRAWING SET

DRAWN

CHECKED

DATE

PROJECT NO.

SHEET NO.

CONSTRUCTION

DOCUMENT SET

FOR

CONSTRUCTION

TC

12/21/2016

AH/TZ

1831 E. US HIGHWAY 169

GRAND RAPIDS, MN 55744

USDA FOREST

SERVICE -

NORTHERN

RESEARCH

STATION - ROOF &

SIDING UPGRADE

2012012.04

CD

DEMOLITION

EXTERIOR

ELEVATIONS

A141

SCALE: 1/8" = 1'-0"A141

1 NORTH ELEVATION

SCALE: 1/8" = 1'-0"A141

2 SOUTH ELEVATION

SCALE: 1/8" = 1'-0"A141

3 EAST ELEVATION

SCALE: 1/8" = 1'-0"A141

4 WEST ELEVATION

SCALE: 1/8" = 1'-0"A141

5 HIDDEN ELEVATION SOUTH

SCALE: 1/8" = 1'-0"A141

6 HIDDEN ELEVATION WEST

SCALE: 1/8" = 1'-0"A141

7 HIDDEN ELEVATION NORTH

SCALE: 1/8" = 1'-0"A141

8 HIDDEN ELEVATION EAST

0' 4' 8'0' 4' 8'

0' 4' 8'

0' 4' 8'

0' 4' 8' 0' 4' 8' 0' 4' 8' 0' 4' 8'

SPECIFIC DEMOLITION EXTERIOR ELEVATION NOTES

1 EXISTING GAS METER TO REMAIN.

2 EXISTING GENERATOR TO REMAIN.

3 EXISTING ELECTRIC CONDUIT TO REMAIN.

4 EXISTIING LOUVER TO REMAIN.

5 EXISTING EXHAUST VENT TO REMAIN.

6 REMOVE DOWNSPOUT FOR INSTALLATION OF NEW

DOWNSPOUT.

7 EXISTING ELECTRIC JUNCTION BOX TO REMAIN.

8 EXISTING LIGHT FIXTURE TO REMAIN.

9 REMOVE EXHAUST VENT.

10 EXISTING AIR CONDITIONER TO REMAIN.

11 EXISTING AIR CONDITIONER LINES TO REMAIN.

12 REMOVE EXISTING VENT.

13 EXISTING DUST COLLECTOR SYSTEM TO REMAIN.

14 RELOCATE FENCE POST AWAY FROM BUILDING.

15 EXISTING METAL TRIM TO REMAIN.

16 EXISTING SENSOR TO REMAIN.

17 REMOVE HOSE BIB FOR INSTALLATION OF NEW HOSE BIB.

18 REMOVE WINDOW FOR INSTALLATION OF NEW WINDOW.

19 REMOVE DOOR AND FRAME FOR INSTALLATION OF NEW

DOOR AND FRAME.

20 REMOVE ELECTRIC OUTLET FOR INSTALLATION OF NEW

ELECTRIC OUTLET.

21 REMOVE METAL TRIM.

22 REMOVE CONDUIT.

23 REMOVE ELECTRIC BOX FOR INSTALLATION OF NEW

ELECTRIC BOX.

24 EXISTING FIRE ALARM TO REMAIN.

SCALE: 1/8" = 1'-0"A141

9 HIDDEN ELEVATION SOUTH 9

SCALE: 1/8" = 1'-0"A141

10 HIDDEN ELEVATION NORTH 10

SCALE: 1/8" = 1'-0"A141

11 HIDDEN ELEVATION SOUTH 11

SCALE: 1/8" = 1'-0"A141

12 HIDDEN ELEVATION NORTH 12

SCALE: 1/8" = 1'-0"A141

13 HIDDEN ELEVATION NORTH 13

SCALE: 1/8" = 1'-0"A141

14 HIDDEN ELEVATION SOUTH 14

SCALE: 1/8" = 1'-0"A141

15 HIDDEN ELEVATION WEST 15

0' 4' 8' 0' 4' 8' 0' 4' 8' 0' 4' 8' 0' 4' 8' 0' 4' 8' 0' 4' 8'

GENERAL DEMOLITION EXTERIOR ELEVATION NOTES

1 ALL EXISTING PENETRATIONS AND ATTACHMENTS ON EXTERIOR

WALLS THAT ARE TO REMAIN SHALL BE MODIFIED AS NECESSARY

TO ACCOMMODATE NEW EXTERIOR WALL ASSEMBLY THICKNESS,

PROVIDE FLUSH MOUNTED COVER PLATES UNLESS NOTED

OTHERWISE.

A401

A401

A401

A401

A401

CONFERENCE

ENTRY

OFFICE/LAB

GIS

SHOP/GARAGE

STORAGE

HEADHOUSE

ARCHIVE

PHASE 1 (SIDING)

A501

A501

A501

A501

A501

A501

A501

A501

A501

A501

SIM

A501

SIM

A501

SIM

A501

SIM

A501

SIM

A501

A501

A501

SIM

A501

SIM

A501

SIM

A501

SIM

A501

SIM

A501

SIM

A501

SIM

A501

SIM

A141

A141

A141

A141

A141

A141

A501

SIM

A401

A401

A401

A401

A401

A401

A806

A806

3&4

A806

MIR

A806

A401

A401

A401

A401

A401

A401

A401

A801

A802

A801

A802

A801

A802

A803

A803

A803

A801

A802

A801

A802

A801

A802

SIM

A801

A801

A801

A802

A802

A803

A802

MIR

A806

A806

A802

A806

A806

MIR

SIM

MIR

3 3

33 3

3 3

3 3

3 3 4

4 4

A806

A803

5 5

005A

005B 005C

002A

ARCHITECTURE

ENGINEERING

INTERIOR DESIGN

STRANG, INC.

6411 MINERAL POINT ROAD

MADISON, WI 53705-4395

SHEET NAME

PROJECT TITLE

DRAWING SET

DRAWN

CHECKED

DATE

PROJECT NO.

SHEET NO.

CONSTRUCTION

DOCUMENT SET

FOR

CONSTRUCTION

TC

12/21/2016

AH/TZ

1831 E. US HIGHWAY 169

GRAND RAPIDS, MN 55744

USDA FOREST

SERVICE -

NORTHERN

RESEARCH

STATION - ROOF &

SIDING UPGRADE

2012012.04

CD

FIRST FLOOR

PLAN

A201

SCALE: 1/8" = 1'-0"

A201

FIRST FLOOR PLAN

0' 4' 8'

GENERAL PLAN NOTES

1 ALL DRAWINGS ARE OF EQUAL IMPORTANCE IN

DEFINING THE WORK OF THE CONTRACT

DOCUMENTS. CONTRACTORS SHALL CAREFULLY

STUDY AND COMPARE ALL DRAWINGS DURING THE

BIDDING PERIOD AND BEFORE INSTALLATION OF

THEIR WORK. ANY INCONSISTENCIES IN THE

DRAWING SHALL BE REPORTED PROMPTLY TO THE

CONTRACTING OFFICER FOR CLARIFICATION.

2 DO NOT SCALE DRAWINGS. THE DRAWINGS ARE NOT

NECESSARILY TO SCALE - USE GIVEN DIMENSIONS.

CONTRACTORS SHALL VERIFY ALL CONDITIONS AND

DIMENSIONS AT THE PROJECTS SITE PRIOR TO THE

START OF CONSTRUCTION. ANY INCONSISTENCIES

DISCOVERED BY THE CONTRACTOR SHALL BE

REPORTED PROMPTLY TO THE CONTRACTING

OFFICER FOR CLARIFICATION BEFORE COMMENCING

THE WORK. ALL DIMENSIONS ARE GIVEN FROM FACE

TO FACE OF WALL. SEE WALL SECTIONS AND

PARTITION TYPES FOR EXACT CONSTRUCTION.

3 WHERE SPECIFIC DIMENSIONS, DETAILS OR DESIGN

INTENT CANNOT BE DETERMINED FROM DOCUMENTS

CONSULT THE CONTRACTING OFFICER BEFORE

PROCEEDING WITH WORK.

4 PROTECT WORK IN PLACE DURING CONSTRUCTION.

5 COORDINATE THE AVAILABILITY OF AREAS

REQUIRING WORK WITH THE CONTRACTING

OFFICER.

6 REFER TO HVAC, ELECTRICAL, PLUMBING, AND FIRE

PROTECTION NOTES FOR ADDITIONAL DEMOLITION

AND MODIFICATIONS REQUIRED FOR HVAC,

ELECTRICAL, PLUMBING AND FIRE PROTECTION

SYSTEMS.

SPECIFIC FLOOR PLAN NOTES

1 DORMER ABOVE FLOOR PLAN CUT LEVEL FOR

REFERENCE.

2 PORTION OF WALL TO HAVE 1" RIGID INSULATION IN

LIEU OF 2" RIGID INSULATION FROM FLOOR BASE TO

ROOF AND FROM WINDOW/DOOR ASSEMBLY TO

WINDOOW/DOOR ASSEMBLY, REFER TO DETAIL 3

AND 4/A806.

3 VERTICAL POST, REFER TO TYPICAL DETAIL 1 AND

2/A804.

4 VERTICAL POST AT CORNER, REFER TO TYPICAL

DETAIL 7 AND 8/A806 AND 5/A803. POST LOCATED

ADJACENT TO WINDOWS TO HAVE POST EXTEND TO

WINDOW OPENING SIMILAR TO DETAIL 10/A806,

LENGTH TO WINDOW VARIES.

5 NEW DOOR AND FRAME, SEE DOOR SCHEDULE.

6 EXISITNG INFILL WALL THAT IS RECESSED 3/4" FROM

SURROUNDING EXISTING CMU WALL, INSTALL NEW

3/4" GLASS MAT SHEATHING TO BE FLUSH WITH

EXISTING CMU WALL.

NORTH

DOOR NUMBER MATERIAL HARDWARE SET COMMENT

002A AL SEE SECTION 08 42 13

005A HM 1 4" HEAD

005B HM 2 4" HEAD

005C HM 1 4" HEAD

KEY

AL - ALUMINUM

HM - HOLLOW METAL

DOOR SCHEDULE

REV 03/11/2019

FULLY ADHERED EPDM TO REMAIN

FULLY ADHERED EPDM TO REMAIN

FULLY ADHERED EPDM TO REMAIN

FULLY ADHERED EPDM TO REMAIN

NEW FULLY

ADHERED EPDM

ROOF WITH MINIMUM

4' RIGID INSULATION

A501

A501

A501

A501

A501

A501

A501

A501

A501

10' - 0"

A501

SIM

A501

SIM

A501

SIM

A501

SIM

A501

SIM

A501

SIM

A501

A501

A501

SIM

A501

SIM

A501

SIM

A501

SIM

A501

SIM

A501

SIM

A501

SIM

A501

SIM

A501

SIM

ROOF SLOPE

ROOF SLOPE

ROOF SLOPE

ROOF SLOPE ROOF SLOPE

ROOF SLOPE

NEW FULLY

ADHERED EPDM

ROOF WITH MINIMUM

4' RIGID INSULATION

NEW FULLY

ADHERED EPDM

ROOF WITH MINIMUM

4' RIGID INSULATION

NEW FULLY

ADHERED EPDM

ROOF WITH MINIMUM

4' RIGID INSULATION

NEW FULLY

ADHERED EPDM

ROOF WITH MINIMUM

4' RIGID INSULATION

NEW FULLY

ADHERED EPDM

ROOF WITH MINIMUM

4' RIGID INSULATION

NEW FULLY

ADHERED EPDM

ROOF WITH MINIMUM

4' RIGID INSULATION

NEW FULLY

ADHERED EPDM

ROOF WITH MINIMUM

4' RIGID INSULATION

6 6

6 6

6 6

ROOF SLOPE

A804

A804

A804

A804

A804

13 SIM

A804

SIM

A805

A805

A805

ROOF SLOPE

4 4

ARCHITECTURE

ENGINEERING

INTERIOR DESIGN

STRANG, INC.

6411 MINERAL POINT ROAD

MADISON, WI 53705-4395

SHEET NAME

PROJECT TITLE

DRAWING SET

DRAWN

CHECKED

DATE

PROJECT NO.

SHEET NO.

CONSTRUCTION

DOCUMENT SET

FOR

CONSTRUCTION

TC

12/21/2016

AH/TZ

1831 E. US HIGHWAY 169

GRAND RAPIDS, MN 55744

USDA FOREST

SERVICE -

NORTHERN

RESEARCH

STATION - ROOF &

SIDING UPGRADE

2012012.04

CD

ROOF PLAN

A202

SCALE: 1/8" = 1'-0"

A202

ROOF PLAN.

GENERAL PLAN NOTES

1 ALL DRAWINGS ARE OF EQUAL IMPORTANCE IN

DEFINING THE WORK OF THE CONTRACT

DOCUMENTS. CONTRACTORS SHALL CAREFULLY

STUDY AND COMPARE ALL DRAWINGS DURING THE

BIDDING PERIOD AND BEFORE INSTALLATION OF

THEIR WORK. ANY INCONSISTENCIES IN THE

DRAWING SHALL BE REPORTED PROMPTLY TO THE

CONTRACTING OFFICER FOR CLARIFICATION.

2 DO NOT SCALE DRAWINGS. THE DRAWINGS ARE NOT

NECESSARILY TO SCALE - USE GIVEN DIMENSIONS.

CONTRACTORS SHALL VERIFY ALL CONDITIONS AND

DIMENSIONS AT THE PROJECTS SITE PRIOR TO THE

START OF CONSTRUCTION. ANY INCONSISTENCIES

DISCOVERED BY THE CONTRACTOR SHALL BE

REPORTED PROMPTLY TO THE CONTRACTING

OFFICER FOR CLARIFICATION BEFORE COMMENCING

THE WORK. ALL DIMENSIONS ARE GIVEN FROM FACE

TO FACE OF WALL. SEE WALL SECTIONS AND

PARTITION TYPES FOR EXACT CONSTRUCTION.

3 WHERE SPECIFIC DIMENSIONS, DETAILS OR DESIGN

INTENT CANNOT BE DETERMINED FROM DOCUMENTS

CONSULT THE CONTRACTING OFFICER BEFORE

PROCEEDING WITH WORK.

4 PROTECT WORK IN PLACE DURING CONSTRUCTION.

5 COORDINATE THE AVAILABILITY OF AREAS

REQUIRING WORK WITH THE CONTRACTING

OFFICER.

6 REFER TO HVAC, ELECTRICAL, PLUMBING, AND FIRE

PROTECTION NOTES FOR ADDITIONAL DEMOLITION

AND MODIFICATIONS REQUIRED FOR HVAC,

ELECTRICAL, PLUMBING AND FIRE PROTECTION

SYSTEMS.

SPECIFIC ROOF PLAN NOTES

1 BASE BID - NEW ROOF ASSEMBLY ADD TO EXISTING

RIGID INSULATION TO HAVE A MINIMUM OF 4" OF

TOTAL RIGID INSULATION. ADD-ALT: NEW

ROOF ASSEMBLY TO HAVE ALL NEW MINIMUM OF 4"

TOTAL RIGID INSULATION.

2 NEW FASCIA AND RAKE TRIM FINISH, TYPICAL

AROUND BUILDING, REFER TO DETAIL 1,2,3 AND

6/A805.

3 EXISTING EXHAUST HOOD CURB, REFER TO DETAIL

7/A804.

4 EXISTING ROOF PENETRATIONS, REFER TO DETAIL

10 AND 11/A804.

5 NEW SCUPPER, REFER TO DETAIL 15/A804.

6 EXISTING SKYLIGHT CURB, REFER TO DETAIL 9/A804.

7 NEW DOWNSPOUT.

8 EXISTING OVERHANG, REFER TO DETAIL 12/A804, 2

AND 3 A/805.

9 NEW SOFFIT VENT.

10 EXISTING AIR HANDLING UNIT CURB, REFER TO

DETAIL 8/A804.

11 EXISTING PARAPET, REFER TO DETAIL 14/A804.

12 EXISTING RECESSED LIGHT FIXTURE UNDER

OVERHANG.

14 EXISTING ROOF VALLEY.

15 EXISTING ROOF RIDGE.

16 ALL VENTS TO BE SEALED AIR TIGHT WHERE NEW

DENSE PACK FIBERGLASS INSULATION IS TO BE

INSTALLED.

17 DASHED AREA TO HAVE DENSE PACK FIBERGLASS

INSULATION INSTALLED OVER EXISTING INSULATION

WITHIN ROOF ALONG PERIMETER EXTERIOR, FILL

VOID FULL WITH INSULATION, FILL RIM JOIST.

18 NEW GUTTER.

19 WRAP ROOF MEMEBRANE UP VERTICAL PARAPET

WALL OVER 1/2" PLYWOOD AND 2" RIGID INSULATION

OVER EXISTING SHEATHING, REFER TO DETAIL

16/A804.

20 NEW MECHANICAL CURB INSTALLED IN PLACE OF

PAD, INSTALL PER 7/A804 (SIM.) AND INSTALL

COUNTERFLASHING MINIMUM 8" ABOVE FULLY

ADHERED EPDM MEMBRANE ROOFING.

21 HATCHED AREA TO HAVE DENSE PACK FIBERGLASS

INSULATION INSTALLED OVER EXISTING INSULATION

WITHIN ROOF ALONG PERIMETER EXTERIOR, FILL

VOID FULL WITH INSULATION, FILL CAVITY SPACE.

22 OLD SKYLIGHT FRAMING TO REMAIN, DENSE PACK

FIBERGLASS INSULATION TO BE INSTALLED

AROUND FRAMING.

0' 4' 8'

NORTH

CONCEALED FASTNER

METAL PANEL (MP-2),

TYPICAL

METAL

HORIZONTAL TRIM

BAND (M-1), TYPICAL

CONCEALED FASTENER

CORRUGATED HORIZONTAL

METAL PANEL (MP-1), TYPICAL

FULLY ADHERED

EPDM ROOF (R-1),

TYPICAL

VERTICAL POST

(M-2), TYPICAL

FASCIA TRIM (FT-1),

TYPICAL

RAKE TRIM (RT-1),

TYPICAL

A501

A501

5 5 5

6 6

6 68 18 18 18

UPPER HORIZONTAL

BAND, REFER TO

DETAIL 3 AND 4/A804,

TYPICAL

LOWER HORIZONTAL

BAND, REFER TO

DETAIL 5 AND 6/A804,

TYPICAL

VERTICAL POST,

REFER TO DETAIL 1

AND 2/A804, TYPICAL

M-1 MP-1

MP-2 MP-2

M-1 MP-1

MP-2MP-2

FT-1

M-2

M-1 MP-2

MP-1 2222

M-2

M-2

M-2

M-2

M-2

M-2

M-2

SOFFIT

PANEL (S-1)

VERTICAL POST

@ EXPOSED TOP

CONDITION, REFER

TO DETAIL 9/A806

3 17

FIRST FLOOR

100' - 0"

CULTURED STONE

(CS-1), TYPICAL

S-1

EXISTING WINDOWS,

TYPICAL

R-1

R-1 RT-1FT-1 FT-1

M-2

MP-2

M-1

MP-2

MP-1

MP-1 M-2 M-1

A501

A501

A501

M-2M-2

M-2

M-2

M-2 M-2 M-2 M-2

M-2 M-2 M-2

M-1 M-1 M-1

M-1

MP-2

MP-2S-1 M-3

MP-2

EXISTING WINDOW,

TYPICAL

MP-1

S-1

S-1

S-1

TYPICAL

BETWEEN

CLERESTORY

WINDOWS

15 VERTICAL POST

@ EXPOSED TOP

CONDITION, REFER

TO DETAIL 2/A806

FT-1

VERTICAL

TRANSITION,

REFER TO DETAIL 15

AND 16/A802, TYPICAL

15 15

FIRST FLOOR

100' - 0"

CS-1

R-1

S-1

M-2

MP-2

M-1

MP-2MP-1

EXISTING WINDOW,

TYPICAL

RT-1

FT-1

P-2

P-2 P-2 MP-1 M-2 P-2

MP-2

S-1 M-1

FT-1

MP-2

A501

M-1

M-2

M-2

M-2M-2M-2M-2M-2

M-2

M-1

".8

MP-2

M-2M-2

M-2 CS-1

EXISTING DOOR AND

FRAME, PAINT (P-2), TYPICAL

3 8 8 824 10 1111 13

17 18

M-1

RT-1

RT-1

MP-1

M-3 15

TYPICAL

BETWEEN

CLERESTORY

WINDOWS

HIDDEN PORTION

OF ELEVATION,

SEE ABOVE

FT-1

MP-2

FIRST FLOOR

100' - 0"

CS-1

EXISTING WINDOWS,

TYPICAL

R-1

M-2

MP-2

M-1

MP-2

MP-1

RT-1

FT-1

P-2 P-2 MP-1M-2

MP-2

S-1

M-1

RT-1

MP-2

M-1M-2

S-1

S-1

P-2

M-2

A501

A501

P-2 P-2

M-2

M-2

M-2

M-2 M-2

M-2

M-2

M-2

BEYOND

M-2

M-2

3 3 3

46 6 6

10 101114

M-1

M-1

M-1

MP-1MP-2

MP-1

MP-2

MP-2

EXISTING WINDOWS,

TYPICAL

CS-1

M-1

FIRST FLOOR

100' - 0"

FT-1

EXISTING WINDOWS, TYPICAL

MP-2P-2MP-1

A501

M-2 M-2

M-2 M-2 M-2M-1

M-1

M-1

MP-2

MP-1

MP-2

S-1

FIRST FLOOR

100' - 0"

FT-1

MP-2 P-2MP-1M-1 M-2

FT-1 R-1

" M-2 M-213 M-2 MP-1M-1

8 S-18

FIRST FLOOR

100' - 0"

EXISTING WINDOWS, TYPICAL

MP-2MP-1M-1 M-2

M-2

FIRST FLOOR

100' - 0"

FT-1

MP-2MP-1M-1 M-2

R-1 S-1

M-2 M-2 M-2

M-2

20202020

FIRST FLOOR

100' - 0"

M-1MP-2

M-2 MP-1

FT-1

FIRST FLOOR

100' - 0"

M-1

MP-2

M-2

MP-1

FT-1

FIRST FLOOR

100' - 0"

M-1

MP-1

MP-2

RT-1

M-2

S-1

FIRST FLOOR

100' - 0"

M-1

MP-1

MP-2

FT-1

M-2

S-1

FIRST FLOOR

100' - 0"

M-1

MP-1

MP-2

RT-1

M-2

S-1

FIRST FLOOR

100' - 0"

M-1

MP-1

MP-2

FT-1

M-2

FIRST FLOOR

100' - 0"

FT-1

MP-1

MP-2

M-1 M-2

ARCHITECTURE

ENGINEERING

INTERIOR DESIGN

STRANG, INC.

6411 MINERAL POINT ROAD

MADISON, WI 53705-4395

SHEET NAME

PROJECT TITLE

DRAWING SET

DRAWN

CHECKED

DATE

PROJECT NO.

SHEET NO.

CONSTRUCTION

DOCUMENT SET

FOR

CONSTRUCTION

TC

12/21/2016

AH/TZ

1831 E. US HIGHWAY 169

GRAND RAPIDS, MN 55744

USDA FOREST

SERVICE -

NORTHERN

RESEARCH

STATION - ROOF &

SIDING UPGRADE

2012012.04

CD

EXTERIOR

ELEVATIONS

A401

SCALE: 1/8" = 1'-0"A401

1 NORTH ELEVATION

SCALE: 1/8" = 1'-0"A401

2 SOUTH ELEVATION

SCALE: 1/8" = 1'-0"A401

3 EAST ELEVATION

SCALE: 1/8" = 1'-0"A401

4 WEST ELEVATION

SCALE: 1/8" = 1'-0"A401

5 HIDDEN ELEVATION SOUTH

SCALE: 1/8" = 1'-0"A401

6 HIDDEN ELEVATION WEST

SCALE: 1/8" = 1'-0"A401

8 HIDDEN ELEVATION EAST

SCALE: 1/8" = 1'-0"A401

7 HIDDEN ELEVATION NORTH

0' 4' 8' 0' 4' 8'

0' 4' 8'

0' 4' 8'

0' 4' 8' 0' 4' 8' 0' 4' 8' 0' 4' 8'

EXTERIOR FINISH SCHEDULE

MP-1 CONCEALED FASTENER

CORRUGATED METAL PANEL

FIRESTONE CFP-16F

(HORIZONTAL)

MP-2 CONCEALED FASTENER

CORRUGATED METAL PANEL

FIRESTONE CFP-12 (VERTICAL

AND HORIZONTAL)

CS-1 CULTURERED STONE BORAL

M-1 METAL TRIM OVER 2X4 BLOCKING

(HORIZONTAL BAND)

M-2 METAL TRIM OVER 2X4 BLOCKING

AND PLYWOOD (VERTICAL POST)

M-3 METAL TRIM OVER RIGID

INSULATION

P-1 PAINT EXISTING OVERHEAD DOOR

AND TRIM

SHERWIN WILLIAMS

P-2 PAINT EXISTING MAN DOOR AND

FRAME

SHERWIN WILLIAMS

FT-1 FASCIA TRIM -----

RT-1 RAKE TRIM -----

S-1 SOFFIT FIRESTONE CFP-12

R-1 FULLY ADHERED EPDM

MEMBRANE ROOFING

GENERAL EXTERIOR ELEVATION NOTES.

1 PAINT EXISTING PIPING, CONDUIT, JUNCTION BOXES, HOSES, VENT

COVERS AND PENETRATIONS THROUGH WALLS, COLOR TO MATCH

ADJACENT FINISH MATERIAL, REFER TO DETAIL 11/A806 FOR

PENETRATIONS AT METAL PANELS.

SPECIFIC NEW ELEVATION NOTES

1 GAS METER.

2 GENERATOR.

3 ELECTRIC CONDUIT.

4 LOUVER, PAINT TO MATCH ADJACENT METAL PANEL COLOR.

5 EXHAUST VENT.

6 NEW DOWNSPOUT, COLOR TO MATCH FASCIA COLOR.

7 ELECTRIC JUNCTION BOX, REFER TO ELECTRICAL NOTES ON SHEET

T001.

8 LIGHT FIXTURE.

9 NEW ELECTRIC BOX.

10 AIR CONDITIONER.

11 AIR CONDITIONER LINES. FABRICATE NEW COVERS, MATCH

ADJACENT SIDING COLOR.

12 NEW METAL TRIM, PAINT TO MATCH M-2 VERTICAL POSTS.

13 DUST COLLECTION SYSTEM.

14 RELOCATED FENCE POST, PLACE MAXIMUM 4" AWAY FROM OUTER

EDGE OF BUILDING.

15 EXISTING METAL TRIM, PAINT TO MATCH M-2 VERTICAL POSTS.

16 SENSOR.

17 NEW HOSE BIB, FIXTURE EQUAL TO WOODFORD MODEL 67,

BACKFLOW PROTECTED FREEZELESS, CONNECT TO EXISTING PIPING

AS REQUIRED, VERIFY ASSEMBLY SIZE WITH WALL THICKNESS.

18 NEW WINDOW TO MATCH EXISTING.

19 NEW DOOR AND FRAME, PAINT (P-2).

20 NEW ELECTRICAL OUTLET, COVER PLATE TO MATCH ADJACENT

METAL PANEL COLOR.

21 EXISTING DOOR AND FRAME, SCRAPE PAINT AND PREP FOR NEW

PAINT (P-2).

22 EXISTING OVERHEAD DOOR AND FRAME, PAINT (P-1).

24 NEW GFCI ELECTRIC OUTLET WITH COVER, MATCH ADJACENT METAL

PANEL COLOR, REFER TO ELECTRICAL NOTES ON T001.

25 UPPER AND LOWER HORIZONTAL BAND IN THIS AREA WHERE 1"

INSULATION IS USED TO HAVE THE HORIZONTAL BAND MADE UP OF

TRANSITION TRIM SIMILAR TO WHAT IS SHOWN ON DETAIL 15/A802,

COLOR TO MATCH HORIZONTAL BAND COLOR USED ON OTHER AREAS

OF BUILDING.

26 FIRE ALARM.

27 CULTURED STONE STARTER TO BE 2" ABOVE STOOP WITH PRECAST

STONE CURB BETWEEN STOOP AND CULTURED STONE STARTER.

SCALE: 1/8" = 1'-0"A401

9 HIDDEN ELEVATION SOUTH 9.

SCALE: 1/8" = 1'-0"A401

10 HIDDEN ELEVATION NORTH 10.

SCALE: 1/8" = 1'-0"A401

11 HIDDEN ELEVATION SOUTH 11.

SCALE: 1/8" = 1'-0"A401

12 HIDDEN ELEVATION NORTH 12.

SCALE: 1/8" = 1'-0"A401

13 HIDDEN ELEVATION NORTH 13.

SCALE: 1/8" = 1'-0"A401

14 HIDDEN ELEVATION SOUTH 14.

SCALE: 1/8" = 1'-0"A401

15 HIDDEN ELEVATION WEST 15.

0' 4' 8' 0' 4' 8' 0' 4' 8' 0' 4' 8' 0' 4' 8' 0' 4' 8' 0' 4' 8'

2" RIGID INSULATION

CONCEALED FASTNER

CORRUGATED HORIZONTAL

METAL PANEL (MP-1)

FLUID APPLIED AIR BARRIER

OVER EXISTING SHEATHING

EXISTINGNEW

PREFINISHED METAL TRIM

OVER RIGID INSULATION

A801

EXISTING WINDOW

A805

SIM

FULLY ADHERED EPDM

MEMBRANE ROOFING

4" MINIMUM RIGID INSULATION

A801

FIRST FLOOR

100' - 0"

EXISTINGNEW

2" RIGID INSULATION

CONCEALED FASTNER

CORRUGATED HORIZONTAL

METAL PANEL (MP-1)

FLUID APPLIED AIR BARRIER

OVER EXISTING SHEATHING

PREFINISHED METAL TRIM

OVER RIGID INSULATION

EXISTING WINDOW

FULLY ADHERED EPDM

MEMBRANE ROOFING

4" MINIMUM RIGID INSULATION

A801

A805

A801

SIM

FIRST FLOOR

100' - 0"

2" RIGID INSULATION

CONCEALED FASTENER

CORRUGATED HORIZONTAL

METAL PANEL (MP-1)

7/8" HAT CHANNELS

FLUID APPLIED AIR BARRIER

OVER EXISTING SHEATHING

EXISTINGNEW

CONCEALED FASTENER

CORRUGATED VERTICAL

METAL PANEL (MP-2)

A805

EXISTING WINDOW

FULLY ADHERED EPDM

MEMBRANE ROOFING

4" MINIMUM RIGID INSULATION

A801

A801

SIM

A802

SIM

FIRST FLOOR

100' - 0"

2" RIGID INSULATION

CONCEALED FASTNER

CORRUGATED HORIZONTAL

METAL PANEL (MP-1)

7/8" HAT CHANNELS

EXISTINGNEW

CONCEALED FASTNER

CORRUGATED HORIZONTAL

METAL PANEL (MP-2)

CONCEALED FASTNER

CORRUGATED HORIZONTAL

METAL PANEL (MP-2)

FLUID APPLIED AIR BARRIER

OVER EXISTING CMU

A802

A801

A801

A805

SIM

SIM

EXISTING FULLY ADHERED EPDM

MEMBRANE ROOFING

DENSE PACK FIBERGLASS

INSULATION OVER EXISTING

INSULATION, FIILL CAVITY FULL

WITH INSULATION

A804

SIM

FIRST FLOOR

100' - 0"

EXISTINGNEW

EXISTING OVERHEAD

DOOR

2" RIGID INSULATION

7/8" HAT CHANNELS

CONCEALED FASTNER

CORRUGATED HORIZONTAL

METAL PANEL (MP-2)

FLUID APPLIED AIR BARRIER

OVER EXISTING CMU

A802

SIM

EXISTING FULLY ADHERED EPDM

MEMBRANE ROOFING

DENSE PACK FIBERGLASS

INSULATION OVER EXISTING

INSULATION, FIILL CAVITY FULL

WITH INSULATION

A805

FIRST FLOOR

100' - 0"

EXISTINGNEW

2" RIGID INSULATION

CONCEALED FASTNER

CORRUGATED HORIZONTAL

METAL PANEL (MP-1)

7/8" HAT CHANNELS

CONCEALED FASTNER

CORRUGATED VERTICAL

METAL PANEL (MP-2)

CONCEALED FASTNER

CORRUGATED HORIZONTAL

METAL PANEL (MP-2)

FLUID APPLIED AIR BARRIER

OVER EXISTING SHEATHING

A801

A801

SIM

A805

SIM

FULLY ADHERED EPDM

MEMBRANE ROOFING

4" MINIMUM RIGID INSULATION

A801

A802

SIM

A804

FIRST FLOOR

100' - 0"

EXISTINGNEW

2" RIGID INSULATION

CONCEALED FASTENER

CORRUGATED HORIZONTAL

METAL PANEL (MP-2)

7/8" HAT CHANNELS

FLUID APPLIED AIR BARRIER

OVER EXISTING SHEATHING

CONCEALED FASTENER

CORRUGATED HORIZONTAL

METAL PANEL (MP-2)

CONCEALED FASTENER

CORRUGATED HORIZONTAL

METAL PANEL (MP-1)

A805

EXISTING FULLY ADHERED

EPDM MEMBRANE ROOFING

A802

SIM

A801

A804

SIM

2" RIGID INSULATION

CULTURED STONE VENEER

EXISTINGNEW

LATH AND MORTAR

SETTING BED

CONCEALED FASTENER

CORRUGATED HORIZONTAL

METAL PANEL (MP-2)

7/8" HAT CHANNELS

FLUID APPLIED AIR BARRIER

OVER EXISTING SHEATHING

FULLY ADHERED EPDM

MEMBRANE ROOFING

4" MINIMUM RIGID INSULATION

A805

A804

SIM

A803

MIR

EXISTINGNEW

2" RIGID INSULATION

CULTURED STONE VENEER

LATH AND MORTAR

SETTING BED

A803

A803

A805

FULLY ADHERED EPDM

MEMBRANE ROOFING

4" MINIMUM RIGID INSULATION

MIR

ARCHITECTURE

ENGINEERING

INTERIOR DESIGN

STRANG, INC.

6411 MINERAL POINT ROAD

MADISON, WI 53705-4395

SHEET NAME

PROJECT TITLE

DRAWING SET

DRAWN

CHECKED

DATE

PROJECT NO.

SHEET NO.

CONSTRUCTION

DOCUMENT SET

FOR

CONSTRUCTION

TC

12/21/2016

AH/TZ

1831 E. US HIGHWAY 169

GRAND RAPIDS, MN 55744

USDA FOREST

SERVICE -

NORTHERN

RESEARCH

STATION - ROOF &

SIDING UPGRADE

2012012.04

CD

WALL SECTIONS

A501

SCALE: 3/4" = 1'-0"

A501

WALL SECTION A

SCALE: 3/4" = 1'-0"

A501

WALL SECTION B

SCALE: 3/4" = 1'-0"

A501

WALL SECTION C

SCALE: 3/4" = 1'-0"

A501

WALL SECTION D

SCALE: 3/4" = 1'-0"

A501

WALL SECTION E

SCALE: 3/4" = 1'-0"

A501

WALL SECTION F

SCALE: 3/4" = 1'-0"

A501

WALL SECTION G

SCALE: 3/4" = 1'-0"

A501

WALL SECTION H

SCALE: 3/4" = 1'-0"

A501

WALL SECTION J

0' 1' 4" 8"

0' 1' 4" 8"

0' 1' 4" 8"

0' 1' 4" 8"

0' 1' 4" 8"

0' 1' 4" 8"

0' 1' 4" 8"

0' 1' 4" 8"

0' 1' 4" 8"

2"7/8"7/8"

EXISTINGNEW

EXISTING SHEATHING

EXISTING STUD WALL

EXISTING GYPSUM BOARD

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 16" O.C.

CONCEALED FASTENER

CORRUGATED

HORIZONTAL METAL

PANEL

EXISTINGNEW

EXISTING SHEATHING

EXISTING STUD WALL

EXISTING GYPSUM BOARD

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 16" O.C.

CONCEALED FASTENER

CORRUGATED

HORIZONTAL METAL

PANEL

EXISTING WINDOW

PREFINISHED METAL FLASHING

(2) 2X4 BLOCKING

WOOD BLOCKING FOR

ATTACHMENT OF

HORIZONTAL TRIM

PITCH TOP OF

HORIZONTAL

TRIM AWAY FROM

BUILDING

SEALANT

HORIZONTAL TRIM

SEALANT, DO NOT COVER UP

WINDOW WEEP HOLES

1 1/4".

2"7/8"7/8"

EXISTINGNEW

EXISTING CMU WALL

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 16" O.C.

CONCEALED FASTENER

CORRUGATED

HORIZONTAL METAL

PANEL

EXISTING SHEATHING

EXISTING STUD WALL

EXISTING GYPSUM BOARD

FLUID APPLIED

AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL @ 16" O.C.

CONCEALED FASTENER CORRUGATED

HORIZONTAL METAL PANEL

EXISTINGNEW

2"7/8"7/8"

PREFINISHED METAL OUTSIDE

CORNER TRIM

3"

METAL PANEL TRIM CLOSURE

EXISTING CMU WALL

FLUID APPLIED

AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL @ 16" O.C.

CONCEALED FASTENER CORRUGATED

HORIZONTAL METAL PANEL

EXISTINGNEW

2"7/8"7/8"

PREFINISHED METAL OUTSIDE

CORNER TRIM

3"

METAL PANEL TRIM CLOSURE

2"7/8"7/8"

EXISTINGNEW

EXISTING SHEATHING

EXISTING STUD WALL

EXISTING GYPSUM BOARD

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 16" O.C.

CONCEALED FASTENER

CORRUGATED

HORIZONTAL METAL

PANEL

2X BLOCKING

PREFINISHED METAL PANAL

BOTTOM CLOSURE TRIM W/

WEEPS, LAP FOUNDATION

SEALANT

GRADE

2"7/8"7/8"

EXISTINGNEW

EXISTING CMU

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 16" O.C.

CONCEALED FASTENER

CORRUGATED

HORIZONTAL METAL

PANEL

2X BLOCKING

PREFINISHED METAL PANAL

BOTTOM CLOSURE TRIM W/

WEEPS, LAP FOUNDATION

SEALANT

GRADE

EXISTINGNEW

EXISTING CMU WALL

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 16" O.C.

CONCEALED FASTENER

CORRUGATED

HORIZONTAL METAL

PANEL

EXISTING WINDOW

PREFINISHED METAL PANEL

CLOSURE TRIM W/ DRIP EDGE

WOOD BLOCKING FOR

ATTACHMENT OF

CLOSURE TRIM

PITCH TOP OF

HORIZONTAL

TRIM AWAY FROM

BUILDING

SEALANT, DO NOT COVER UP

WINDOW WEEP HOLES

E X

IS

T

IN

G

N E

W

EXISTING STUD WALL

EXISTING GYPSUM BOARD

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 16" O.C.

CONCEALED FASTENER

CORRUGATED

HORIZONTAL METAL PANEL

EXISTING SHEATHING

PREFINISHED METAL

PANEL CLOSURE TRIM

EXISTING WINDOW

SEALANT

METAL PANEL TRIM

CLOSURE

E X

IS

T

IN

G

N E

W

EXISTING CMU WALL

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 16" O.C.

CONCEALED FASTENER

CORRUGATED

HORIZONTAL METAL PANEL

PREFINISHED METAL

PANEL CLOSURE TRIM

EXISTING WINDOW

SEALANT

METAL PANEL TRIM

CLOSURE

E X

IS

T

IN

G

N E

W

EXISTING STUD WALL

EXISTING GYPSUM BOARD

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 16" O.C.

CONCEALED FASTENER

CORRUGATED

HORIZONTAL METAL PANEL

EXISTING SHEATHING

PREFINISHED METAL

PANEL CLOSURE TRIM

EXISTING DOOR

EXISTING

DOOR

FRAME

SEALANT

METAL PANEL

TRIM CLOSURE

E X

IS

T

IN

G

N E

W

EXISTING CMU WALL

FLUID APPLIED AIR BARRIER, EXTEND

INTO ROUGH OPENING AS SHOWN

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 16" O.C.

CONCEALED FASTENER

CORRUGATED

HORIZONTAL METAL PANEL

PREFINISHED METAL

PANEL CLOSURE TRIM

DOOR

DOOR

FRAME

SEALANT

SEALANT

METAL PANEL

TRIM CLOSURE

EXISTING STUD WALL

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

PREFINISHED METAL INSIDE

CORNER TRIM

7/8" HAT CHANNEL

@ 16" O.C.

CONCEALED FASTENER

CORRUGATED HORIZONTAL

METAL PANEL

WOOD BLOCKING

E X

IS

T

IN

G

N E

W EXISTING SHEATHING

EXISTING GYPSUM BOARD

/8

/8

EXISTING CMU WALL

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

PREFINISHED METAL INSIDE

CORNER TRIM

CONCEALED FASTENER

CORRUGATED HORIZONTAL

METAL PANEL

WOOD BLOCKING

E X

IS

T

IN

G

N E

W

7/8" HAT CHANNEL

@ 12" O.C.

/8

/8

2"7/8"7/8"

EXISTINGNEW

EXISTING SHEATHING

EXISTING STUD WALL

EXISTING GYPSUM BOARD

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 16" O.C.

CONCEALED FASTENER

CORRUGATED HORIZONTAL

METAL PANEL

1/8" X 1" NON-CURING BUTYL TAPE

M

IN

L A

P

PLAN VIEW

NOTCH BACK FASTENING

FLANGE AND HOOK FOR

OVERLAP CLEARANCE

2"7/8"7/8"

EXISTINGNEW

EXISTING CMU WALL

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 16" O.C.

CONCEALED FASTENER

CORRUGATED HORIZONTAL

METAL PANEL

1/8" X 1" NON-CURING BUTYL TAPE

M

IN

L A

P

PLAN VIEW

NOTCH BACK FASTENING

FLANGE AND HOOK FOR

OVERLAP CLEARANCE

ARCHITECTURE

ENGINEERING

INTERIOR DESIGN

STRANG, INC.

6411 MINERAL POINT ROAD

MADISON, WI 53705-4395

SHEET NAME

PROJECT TITLE

DRAWING SET

DRAWN

CHECKED

DATE

PROJECT NO.

SHEET NO.

CONSTRUCTION

DOCUMENT SET

FOR

CONSTRUCTION

TC

12/21/2016

TZ/TC

1831 E. US HIGHWAY 169

GRAND RAPIDS, MN 55744

USDA FOREST

SERVICE -

NORTHERN

RESEARCH

STATION - ROOF &

SIDING UPGRADE

2012012.04

CD

EXTERIOR

DETAILS

A801

SCALE: 3" = 1'-0"A801

9 (MP-1) SEAM DETAIL @ STUD

SCALE: 3" = 1'-0"A801

3 (MP-1) WINDOW SILL DETAIL @ STUD

SCALE: 3" = 1'-0"A801

10 (MP-1) SEAM DETAIL @ CMU

SCALE: 3" = 1'-0"A801

11 (MP-1) OUTSIDE CORNER DETAIL @ STUD

SCALE: 3" = 1'-0"A801

12 (MP-1) OUTSIDE CORNER DETAIL @ CMU

SCALE: 3" = 1'-0"A801

1 (MP-1) BASE DETAIL @ STUD

SCALE: 3" = 1'-0"A801

2 (MP-1) BASE DETAIL @ CMU

SCALE: 3" = 1'-0"A801

4 (MP-1) WINDOW SILL DETAIL @ CMU

SCALE: 3" = 1'-0"A801

5 (MP-1) WINDOW JAMB DETAIL @ STUD

SCALE: 3" = 1'-0"A801

6 (MP-1) WINDOW JAMB DETAIL @ CMU

SCALE: 3" = 1'-0"A801

7 (MP-1) DOOR JAMB DETAIL @ STUD

SCALE: 3" = 1'-0"A801

8 (MP-1) DOOR JAMB DETAIL @ CMU

SCALE: 3" = 1'-0"A801

13 (MP-1) INSIDE CORNER DETAIL @ STUD

SCALE: 3" = 1'-0"A801

14 (MP-1) INSIDE CORNER DETAIL @ CMU

SCALE: 3" = 1'-0"A801

15 (MP-1) OVERLAP SEAM JOINT @ STUD

SCALE: 3" = 1'-0"A801

16 (MP-1) OVERLAP SEAM JOINT @ CMU

0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4"

0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4"

0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4"

E X

IS

T

IN

G

N E

W

EXISTING STUD WALL

EXISTING GYPSUM BOARD

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 12" O.C.

CONCEALED FASTENER

CORRUGATED

VERTICAL METAL PANEL

EXISTING SHEATHING

PREFINISHED METAL

PANEL CLOSURE TRIM

EXISTING WINDOW

WOOD BLOCKING

NOTE: EXISTING METAL TRIM

AROUND WINDOW TO REMAIN AS

CALLED OUT ON ELEVATION 2, 3

AND 4/A141, KEY NOTE 15.

METAL PANELS TO BUTT UP

AGAINST METAL TRIM.

E X

IS

T

IN

G

N E

W

EXISTING STUD WALL

EXISTING GYPSUM BOARD

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

EXISTING SHEATHING

EXISTING DOOR

EXISTING

DOOR

FRAME

SEALANT

CONCEALED FASTENER

CORRUGATED

VERTICAL METAL PANEL

PREFINISHED METAL

PANEL CLOSURE TRIM

WOOD BLOCKING

7/8" HAT CHANNEL

@ 12" O.C.

E X

IS

T

IN

G

N E

W

EXISTING CMU WALL

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 12" O.C.

EXISTING WINDOW

CONCEALED FASTENER

CORRUGATED

VERTICAL METAL PANEL

PREFINISHED METAL

PANEL CLOSURE TRIM

WOOD BLOCKING

E X

IS

T

IN

G

N E

W

EXISTING CMU WALL

FLUID APPLIED AIR BARRIER, EXTEND

INTO ROUGH OPENING AS SHOWN

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 12" O.C.

DOOR

DOOR

FRAME

SEALANT

CONCEALED FASTENER

CORRUGATED

VERTICAL METAL PANEL

PREFINISHED METAL

PANEL CLOSURE TRIM

WOOD BLOCKING

SEALANT

EXISTINGNEW

PREFINISHED METAL

PANEL CLOSURE TRIM

W/ WEEPS

EXISTING SHEATHING

EXISTING STUD WALL

EXISTING GYPSUM BOARD

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 12" O.C.

CONCEALED FASTENER

CORRUGATED

VERTICAL (OR HORIZONTAL)

METAL PANEL

EXISTING WINDOW

SEALANT

2"7/8"7/8"

SEE ELEVATIONS FOR

AREAS WITH

HORIZONTAL BAND

ABOVE WINDOW,

REFER TO 8/A802

FOR SIMILAR DETAIL

METAL PANEL TRIM CLOSURE

EXISTINGNEW

PREFINISHED METAL

PANEL CLOSURE TRIM

W/ WEEPS

EXISTING CMU WALL

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 12" O.C.

CONCEALED FASTENER

CORRUGATED

VERTICAL (OR HORIZONTAL)

METAL PANEL

EXISTING WINDOW

SEALANT

2"7/8"7/8"

METAL PANEL TRIM CLOSURE

EXISTINGNEW

PREFINISHED METAL

PANEL CLOSURE TRIM

W/ WEEPS

EXISTING SHEATHING

EXISTING STUD WALL

EXISTING GYPSUM BOARD

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 12" O.C.

CONCEALED FASTENER

CORRUGATED

VERTICAL (OR HORIZONTAL)

METAL PANEL

SEE ELEVATIONS FOR

AREAS WITH

HORIZONTAL BAND

ABOVE DOOR, REFER

TO 8/A802 FOR

SIMILAR DETAIL

SEALANT AND BACKER

ROD

2"7/8"7/8"

EXISTING DOOR FRAME

EXISTING DOOR

METAL PANEL TRIM CLOSURE

EXISTINGNEW

EXISTING CMU WALL

FLUID APPLIED AIR BARRIER,

EXTEND INTO ROUGH OPENING

AS SHOWN

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 12" O.C.

CONCEALED FASTENER

CORRUGATED

VERTICAL (OR HORIZONTAL)

METAL PANEL

DOOR

SEALANT AND BACKER

ROD

2"7/8"7/8"

SEALANT

DOOR FRAME

PREFINISHED METAL BOTTOM

CLOSURE "J" TRIM W/ WEEPS

(2) 2X4 BLOCKING

WOOD BLOCKING FOR

ATTACHMENT OF

HORIZONTAL TRIM

PITCH TOP OF HORIZONTAL

TRIM AWAY FROM BUILDING

HORIZONTAL TRIM

EXISTING SHEATHING

EXISTING STUD WALL

EXISTING GYPSUM BOARD

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 12" O.C.

CONCEALED FASTENER

CORRUGATED VERTICAL

(OR HORIZONTAL)

METAL PANEL

EXISTINGNEW

2"7/8"7/8"

PREFINISHED METAL OUTSIDE

CORNER TRIM

3"

WOOD BLOCKING

EXISTING CMU WALL

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

EXISTINGNEW

2"7/8"7/8"

PREFINISHED METAL OUTSIDE

CORNER TRIM

3"

7/8" HAT CHANNEL

@ 12" O.C.

CONCEALED FASTENER

CORRUGATED VERTICAL

(OR HORIZONTAL)

METAL PANEL

3"

WOOD BLOCKING

EXISTING STUD WALL

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

PREFINISHED METAL INSIDE

CORNER TRIM

7/8" HAT CHANNEL

@ 12" O.C.

CONCEALED FASTENER

CORRUGATED VERTICAL

(OR HORIZONTAL)

METAL PANEL

WOOD BLOCKING

/8

/8

E X

IS

T

IN

G

N E

W EXISTING SHEATHING

EXISTING GYPSUM BOARD

EXISTING CMU WALL

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

PREFINISHED METAL INSIDE

CORNER TRIM

7/8" HAT CHANNEL

@ 12" O.C.

CONCEALED FASTENER

CORRUGATED VERTICAL

(OR HORIZONTAL)

METAL PANEL

WOOD BLOCKING

/8

/8

E X

IS

T

IN

G

N E

W

2"7/8"7/8"

EXISTINGNEW

EXISTING SHEATHING

EXISTING STUD WALL

EXISTING GYPSUM BOARD

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 12" O.C.

CONCEALED FASTENER

CORRUGATED

VERTICAL (OR HORIZONTAL)

METAL PANEL

PLAN VIEW

2"7/8"7/8"

EXISTINGNEW

EXISTING CMU WALL

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 12" O.C.

CONCEALED FASTENER

CORRUGATED

VERTICAL (OR HORIZONTAL)

METAL PANEL

PLAN VIEW

2"7/8"7/8"

EXISTINGNEW

EXISTING SHEATHING

EXISTING STUD WALL

EXISTING GYPSUM BOARD

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 12" O.C.

CONCEALED FASTENER

CORRUGATED

VERTICAL (OR HORIZONTAL)

METAL PANEL

PLAN VIEW

/2

PREFINISHED METAL VERTICAL

TRANSITION TRIM

METAL PANEL TRIM CLOSURE

2"7/8"7/8"

EXISTINGNEW

EXISTING CMU WALL

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 12" O.C.

CONCEALED FASTENER

CORRUGATED

VERTICAL (OR HORIZONTAL)

METAL PANEL

PLAN VIEW

/2

PREFINISHED METAL VERTICAL

TRANSITION TRIM

METAL PANEL TRIM CLOSURE

ARCHITECTURE

ENGINEERING

INTERIOR DESIGN

STRANG, INC.

6411 MINERAL POINT ROAD

MADISON, WI 53705-4395

SHEET NAME

PROJECT TITLE

DRAWING SET

DRAWN

CHECKED

DATE

PROJECT NO.

SHEET NO.

CONSTRUCTION

DOCUMENT SET

FOR

CONSTRUCTION

TC

12/21/2016

TZ/TC

1831 E. US HIGHWAY 169

GRAND RAPIDS, MN 55744

USDA FOREST

SERVICE -

NORTHERN

RESEARCH

STATION - ROOF &

SIDING UPGRADE

2012012.04

CD

EXTERIOR

DETAILS

A802

SCALE: 3" = 1'-0"A802

1 (MP-2) WINDOW JAMB DETAIL @ STUD

SCALE: 3" = 1'-0"A802

3 (MP-2) DOOR JAMB DETAIL @ STUD

SCALE: 3" = 1'-0"A802

2 (MP-2) WINDOW JAMB DETAIL @ CMU

SCALE: 3" = 1'-0"A802

4 (MP-2) DOOR JAMB DETAIL @ CMU

SCALE: 3" = 1'-0"A802

5 (MP-2) WINDOW HEAD DETAIL @ STUD

SCALE: 3" = 1'-0"A802

6 (MP-2) WINDOW HEAD DETAIL @ CMU

SCALE: 3" = 1'-0"A802

7 (MP-2) DOOR HEAD DETAIL @ STUD

SCALE: 3" = 1'-0"A802

8 (MP-2) DOOR HEAD DETAIL @ CMU

SCALE: 3" = 1'-0"A802

11 (MP-2) OUTSIDE CORNER DETAIL @ STUD

SCALE: 3" = 1'-0"A802

12 (MP-2) OUTSIDE CORNER DETAIL @ CMU

SCALE: 3" = 1'-0"A802

13 (MP-2) INSIDE CORNER DETAIL @ STUD

SCALE: 3" = 1'-0"A802

14 (MP-2) INSIDE CORNER DETAIL @ CMU

SCALE: 3" = 1'-0"A802

9 (MP-2) SEAM DETAIL @ STUD

SCALE: 3" = 1'-0"A802

10 (MP-2) SEAM DETAIL @ CMU

SCALE: 3" = 1'-0"A802

15 (MP-2) VERTICAL TRANSITION DETAIL @ STUD

SCALE: 3" = 1'-0"A802

16 (MP-2) VERTICAL TRANSITION DETAIL @ CMU

0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4"

0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4"

0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4"

NOTE: DETAILS SHOWN ON SHEET

A802 SHOW VERTICAL METAL PANEL

APPLICATION, SEE ELEVATIONS ON

SHEET A401 FOR VERTICAL OR

HORIZONTAL METAL PANEL

APPLICATION TO BE INSTALLED

EXISTING SHEATHING

EXISTING STUD WALL

EXISTING GYPSUM BOARD

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

2"

EXISTING NEW

LATH

MORTAR SCRATCH COAT

MORTAR SETTING BED

ADHERED MANUFACTURED

STONE VENEER

WEATHER RESISTIVE BARRIER

EXISTING SHEATHING

EXISTING STUD WALL

EXISTING GYPSUM BOARD

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

PREFINISHED METAL BOTTOM

CLOSURE TRIM W/ WEEPS

AND BUG SCREEN, LAP

FOUNDATION

SEALANT

GRADE

2"

EXISTING NEW

LATH

MORTAR SCRATCH COAT

MORTAR SETTING BED

ADHERED MANUFACTURED

STONE VENEER

WEATHER RESISTIVE BARRIER

EXISTING SHEATHING

EXISTING STUD WALL

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

EXISTING WINDOW

PREFINISHED METAL FLASHING

(2) 2X4 BLOCKING

PITCH TOP OF HORIZONTAL

TRIM AWAY FROM BUILDING

SEALANT

EXISTING NEW

LATH

MORTAR SCRATCH COAT

MORTAR SETTING BED

ADHERED MANUFACTURED

STONE VENEER

SEALANT, DO NOT COVER UP

WINDOW WEEP HOLES

WEATHER RESISTIVE BARRIER

E X

IS

T

IN

G

N E

W

EXISTING STUD WALL

EXISTING GYPSUM BOARD

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

EXISTING SHEATHING

EXISTING WINDOW

SEALANT AND BACKER ROD

LATH

MORTAR SCRATCH COAT

MORTAR SETTING BED

ADHERED MANUFACTURED

STONE VENEER

WEATHER RESISTIVE BARRIER

EXISTING SHEATHING

EXISTING STUD WALL

EXISTING GYPSUM BOARD

FLUID APPLIED

AIR BARRIER

2" RIGID

INSULATION

EXISTINGNEW

2"

LATH

MORTAR SCRATCH COAT

MORTAR SETTING BED

ADHERED MANUFACTURED

STONE VENEER

/4

7 1/4".

2X6 BLOCKING

BLOCKING

PREFINISHED

METAL VERTICAL

TRIM

SEALANT AND

BACKER ROD

2X4 BLOCKING

RUN

HORIZONTALLY

24" O.C. FOR

ATTACHMENT TO

EXISTING STUDS

(DASHED LINES)

TREATED PLYWOOD COVER AT

BASE, SET OFF GROUND 2"

WEATHER

RESISTIVE

BARRIER

EXISTING STUD WALL

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

E X

IS

T

IN

G

N E

W

EXISTING SHEATHING

EXISTING GYPSUM BOARD

LATH

MORTAR SCRATCH COAT

MORTAR SETTING BED

ADHERED MANUFACTURED

STONE VENEER

7/8" HAT CHANNEL

@ 16" O.C.

CONCEALED FASTENER

CORRUGATED HORIZONTAL

METAL PANEL

SEALANT W/ BACKER ROD

/8

/8

WEATHER RESISTIVE BARRIER

E X

IS

T

IN

G

N E

W

EXISTING STUD WALL

EXISTING GYPSUM BOARD

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

EXISTING SHEATHING

DOOR

DOOR

FRAME

SEALANT AND BACKER ROD

SEALANT

LATH

MORTAR SCRATCH COAT

MORTAR SETTING BED

ADHERED MANUFACTURED

STONE VENEER

WEATHER RESISTIVE BARRIER

ARCHITECTURE

ENGINEERING

INTERIOR DESIGN

STRANG, INC.

6411 MINERAL POINT ROAD

MADISON, WI 53705-4395

SHEET NAME

PROJECT TITLE

DRAWING SET

DRAWN

CHECKED

DATE

PROJECT NO.

SHEET NO.

CONSTRUCTION

DOCUMENT SET

FOR

CONSTRUCTION

TC

12/21/2016

TZ/TC

1831 E. US HIGHWAY 169

GRAND RAPIDS, MN 55744

USDA FOREST

SERVICE -

NORTHERN

RESEARCH

STATION - ROOF &

SIDING UPGRADE

2012012.04

CD

EXTERIOR

DETAILS

A803

SCALE: 3" = 1'-0"A803

1 CULTERED STONE SECTION @ STUD

SCALE: 3" = 1'-0"A803

2 CULTURED STONE BASE DETAIL @ STUD

SCALE: 3" = 1'-0"A803

3 CULTURED STONE WINDOW SILL @ STUD

SCALE: 3" = 1'-0"A803

4 CULTURED STONE WINDOW JAMB @ STUD

SCALE: 3" = 1'-0"A803

5 CULTURED STONE OUTSIDE CORNER @ STUD

SCALE: 3" = 1'-0"A803

6 CULTURED STONE INSIDE CORNER @ STUD

0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4"

0' 6"2" 4"

SCALE: 3" = 1'-0"A803

7 CULTURED STONE DOOR JAMB @ STUD

0' 6"2" 4"

7/8"

EXISTING CMU WALL

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 16" O.C.

CONCEALED FASTENER

CORRUGATED HORIZONTAL

METAL PANEL

5/8" PLYWOOD

PLAN VIEW

2X4 WOOD BLOCKING

PREFINISHED METAL

VERTICAL TRIM

NEW

2"7/8"

3 1/4"

METAL PANEL TRIM CLOSURE

PREFINISHED METAL PANEL

CLOSURE TRIM

TREATED PLYWOOD

COVER AT BASE, SET

OFF GROUND 2"

SEALANT AND BACKER

ROD

7/8"

EXISTINGNEW

EXISTING STUD WALL

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 16" O.C.

CONCEALED FASTENER

CORRUGATED HORIZONTAL

METAL PANEL

5/8" PLYWOOD

PLAN VIEW

2X4 WOOD BLOCKING

PREFINISHED METAL

VERTICAL TRIM

EXISTING SHEATHING

EXISTING GYPSUM BOARD

2"7/8"

3 1/4"

METAL PANEL TRIM CLOSURE

PREFINISHED METAL PANEL

CLOSURE TRIM

TREATED PLYWOOD

COVER AT BASE, SET

OFF GROUND 2"

SEALANT AND BACKER

ROD

2"

EXISTINGNEW

EXISTING SHEATHING

EXISTING STUD WALL

EXISTING GYPSUM BOARD

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 12" O.C.

CONCEALED FASTENER

CORRUGATED

HORIZONTAL

METAL PANEL

(2) 2X4 BLOCKING

WOOD BLOCKING FOR

ATTACHMENT OF PREFINISHED

METAL HORIZONTAL TRIM

PITCH TOP OF HORIZONTAL

TRIM AWAY FROM BUILDING

SEALANT

SEALANT

PREFINISHED METAL

HORIZONTAL TRIM

CONCEALED FASTENER

CORRUGATED

HORIZONTAL

METAL PANEL

7/8"7/8"

1 1/4"

2"

EXISTINGNEW

EXISTING CMU WALL

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 12" O.C.

CONCEALED FASTENER

CORRUGATED

HORIZONTAL

METAL PANEL

(2) 2X4 BLOCKING

WOOD BLOCKING FOR

ATTACHMENT OF PREFINISHED

METAL HORIZONTAL TRIM

PITCH TOP OF HORIZONTAL

TRIM AWAY FROM BUILDING

SEALANT

SEALANT

PREFINISHED METAL

HORIZONTAL TRIM

CONCEALED FASTENER

CORRUGATED

HORIZONTAL

METAL PANEL

7/8"7/8"

1 1/4"

2"

EXISTINGNEW

EXISTING SHEATHING

EXISTING STUD WALL

EXISTING GYPSUM BOARD

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 12" O.C.

CONCEALED FASTENER

CORRUGATED

VERTICAL METAL PANEL

(2) 2X4 BLOCKING

WOOD BLOCKING FOR

ATTACHMENT OF PREFINISHED

METAL HORIZONTAL TRIM

PITCH TOP OF HORIZONTAL

TRIM AWAY FROM BUILDING

SEALANT

PREFINISHED METAL

HORIZONTAL TRIM

CONCEALED FASTENER

CORRUGATED

HORIZONTAL

METAL PANEL

7/8"7/8"

PREFINISHED METAL BOTTOM

CLOSURE "J" TRIM W/ WEEPS

1 1/4"

2"

EXISTINGNEW

EXISTING CMU WALL

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 12" O.C.

CONCEALED FASTENER

CORRUGATED

VERTICAL METAL PANEL

(2) 2X4 BLOCKING

WOOD BLOCKING FOR

ATTACHMENT OF PREFINISHED

METAL HORIZONTAL TRIM

PITCH TOP OF HORIZONTAL

TRIM AWAY FROM BUILDING

SEALANT

PREFINISHED METAL

HORIZONTAL TRIM

CONCEALED FASTENER

CORRUGATED

HORIZONTAL

METAL PANEL

7/8"7/8"

PREFINISHED METAL BOTTOM

CLOSURE "J" TRIM W/ WEEPS

1 1/4"

EXISTING EQUIPMENT

EXISTING EQUIPMENT CURB

COUNTERFLASHING FASTENED

APPROX. 18" O.C. - SUPPLIED

AND INSTALLED BY SHEET

METAL CONTRACTOR

FASTENERS APPROX. 8" O.C.

MEMBRANE FLASHING STRIP,

OVERLAP BASE PER ROOFING

MANUFACTURER'S

REQUIREMENTS

FULLY ADHERED EPDM

MEMBRANE ROOFING

2"

NOM.

E X

IS

T

IN

G

WOOD BLOCKING

PIPE

LAP SEALANT

ENTIRE PERIMETER

PREFABRICATED MOULDED

PLASTIC PIPE FLASHING

FULLY ADHERED EPDM

MEMBRANE ROOFING

ROOF INSULATION

(DEPTH VARIES)

ROOF STRUCTURE

LAP SEALANT SEAM EDGE

TREATMENT ENTIRE

PERIMETER

STAINLESS STEEL

CLAMPING RING

PIPE

LAP TEMPERATURE APPROPRIATE

SEALANT ENTIRE PERIMETER

FLASHING MEMBRANE

(ADHERED TO CURB)

FULLY ADHERED EPDM

MEMBRANE ROOFING

ROOF INSULATION

(DEPTH VARIES)

ROOF STRUCTURE

LAP SEALANT SEAM EDGE

TREATMENT ENTIRE

PERIMETER

STAINLESS STEEL

CLAMPING RING

FILL VOID WITH

INSULATION

F L A

S H

IN

G

H T

N O

M

WOOD BLOCKING

REMOVABLE SHEET METAL

COUNTERFLASHING

HIGH-DOMED, CAPPED

GASKETED FASTENERS

SHEET METAL UMBRELLA

PREFINISHED METAL

CAP

PREFINISHED METAL

TRIM ON FASCIA

WALL SYSTEM

* METAL PANEL (MP-2)

* 7/8" HAT CHANNEL

* 2" RIGID INSULATION

* FLUID APPLIED AIR

VAPOR BARRIER

TOP OF ROOF

TOP OF SIDE ROOF

WALL SYSTEM

* METAL PANEL (MP-2)

* 7/8" HAT CHANNEL

* 2" RIGID INSULATION

* FLUID APPLIED AIR

VAPOR BARRIER

PREFINISHED METAL

CAP

PREFINISHED METAL

TRIM ON FASCIA

TOP OF SIDE ROOF

PREFINISHED METAL

PANEL CLOSURE TRIM

W/ WEEPS

EXISTING STRUCTURE

FLUID APPLIED AIR BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 12" O.C.

CONCEALED FASTENER

CORRUGATED

VERTICAL METAL PANEL

METAL PANEL TRIM CLOSURE

FULLY ADHERED EPDM

MEMBRANE ROOFING, EXTEND

UP WALL AND FASTEN TOP WITH

ALUMINUM COMPRESSION BAR

12" O.C.

4" MINIMUM RIGID

INSULATION

SECTION

SECTION CUT,

SEE SECTION

DRAWING BELOW

COUNTERFLASHING

SEALANT

REINFORCE PERIMETER

SECUREMENT STRIP

WITH FASTENER

PLATES 12" O.C.

EXISTING METAL

FLASHING

EXISTING AIR

HANDLING UNIT

CUT EXISTING EPDM

MEMBRANE, TUCK NEW

EPDM MEMBRANE UNDER

OLD, PROVIDE SEALANT

NEW FULLY ADHERED

EPDM MEMBRANE

ROOFING

NEW FULLY ADHERED

EPDM MEMBRANE

ROOFING

REMOVE EXISTING

SKYLIGHT AND

FLASHING, INSTALL

EPDM MEMBRANE ON

TOP OF CURB,

REINSTALL SKYLIGHT

AND NEW FLASHING

PREFINISHED

METAL CAP

W/ DRIP EDGE

2X BLOCKING

FULLY ADHERED EPDM

MEMBRANE ROOFING,

EXTEND UP PARAPET

WALL UNDER FLASHING

EXISTING PARPET WALL

4" MINIMUM RIGID

INSULATION

EXISTING STRUCTURE

PROVIDE 4" MINIMUM

SPRAY FOAM IN CAVITY

SPACE, PATCH

SHEATHING

EXISTING ROOFING

SLOPE

PREFINISHED METAL CAP

BEYOND

FULLY ADHERED EPDM

MEMBRANE ROOFING

WRAPPED OVER

SCUPPER FLASHING

EXISTING CMU WALL

ALUMINUM SCUPPER,

EXTENDS UP SIDE WALLS

AND UNDER METAL CAP

4" MINIMUM RIGID INSULATION

TAPER INSULATION DOWN TO

SCUPPER

EXISTING ROOF STRUCTURE

2x4 BLOCKING

FLUID APPLIED AIR

BARRIER

2" RIGID INSULATION

7/8" HAT CHANNEL

@ 12" O.C.

CONCEALED FASTENER

CORRUGATED

VERTICAL (OR HORIZONTAL)

METAL PANEL

2"

7/8" 7/8"

METAL PANEL TRIM CLOSURE

PREFINISHED METAL

PANEL CLOSURE TRIM

EXISTINGNEW

DOWNSPOUT

PREFINISHED

METAL CAP

W/ DRIP EDGE

2X BLOCKING

FULLY ADHERED EPDM

MEMBRANE ROOFING,

EXTEND UP PARAPET

WALL UNDER FLASHING

EXISTING PARPET WALL

4" MINIMUM RIGID

INSULATION

EXISTING STRUCTURE

2"RIGID INSULATION

1/2" PLYWOOD

PROVIDE SPRAY FOAM IN

CAVITY SPACE, PATCH

SHEATHING

SLOPE

ARCHITECTURE

ENGINEERING

INTERIOR DESIGN

STRANG, INC.

6411 MINERAL POINT ROAD

MADISON, WI 53705-4395

SHEET NAME

PROJECT TITLE

DRAWING SET

DRAWN

CHECKED

DATE

PROJECT NO.

SHEET NO.

CONSTRUCTION

DOCUMENT SET

FOR

CONSTRUCTION

TC

12/21/2016

TZ/TC

1831 E. US HIGHWAY 169

GRAND RAPIDS, MN 55744

USDA FOREST

SERVICE -

NORTHERN

RESEARCH

STATION - ROOF &

SIDING UPGRADE

2012012.04

CD

EXTERIOR

DETAILS

A804

SCALE: 3" = 1'-0"A804

2 VERTICAL POST DETAIL @ CMU

SCALE: 3" = 1'-0"A804

1 VERTICAL POST DETAIL @ STUD

SCALE: 3" = 1'-0"A804

3 UPPER HORIZONTAL BAND DETAIL @ STUD

SCALE: 3" = 1'-0"A804

4 UPPER HORIZONTAL BAND DETAIL @ CMU

SCALE: 3" = 1'-0"A804

5 LOWER HORIZONTAL BAND DETAIL @ STUD

SCALE: 3" = 1'-0"A804

6 LOWER HORIZONTAL DETAIL @ CMU

0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4" 0' 6"2" 4"

SCALE: 1 1/2" = 1'-0"A804

7 EXHAUST HOOD CURB DETAIL

SCALE: 1 1/2" = 1'-0"A804

10 ROOF PENETRATION COLD PIPE

SCALE: 1 1/2" = 1'-0"A804

11 ROOF PENETRATION HOT PIPE

0' 1'4" 8" 0' 1'4" 8" 0' 1'4" 8" 0' 1'4" 8"

SCALE: 3/4" = 1'-0"A804

13 CLERESTORY ROOF DETAIL 2

SCALE: 3/4" = 1'-0"A804

12 CLERESTORY ROOF DETAIL 1

0' 1'4" 8"0' 1'4" 8"

SCALE: 3" = 1'-0"A804

8 AIR HANDLING UNIT CURB DETAILS

SCALE: 3" = 1'-0"A804

9 SKYLIGHT SECTION

SCALE: 3" = 1'-0"A804

14 PARAPET DETAIL @ ROOF

0' 1'4" 8"

0' 6"2" 4"

SCALE: 3" = 1'-0"A804

15 SCUPPER DETAIL

0' 6"2" 4"

SCALE: 3" =…

This is the start of the file's text. The full file is on GovTribe.