This document is a detailed Questions and Answers (Q&A) document for the Lolo National Forest T-150 Building Reconstruction project (Solicitation #1240LU25R0018), scheduled for bid opening on 08/08/2025 at 11:00 am. The document contains 60 questions and answers covering various technical aspects of the project, including clarifications on option items, lighting fixtures, fencing, building permits, material substitutions, and project specifications. Key details include: the project is a small business set-aside, no local building permits are required, bonding is required but builders risk is not, and there are multiple optional items such as Fitness and Restroom Areas. Substitution requests for products like Drexel Metals roofing, Arcadia components, and OCC networking equipment were approved and will be incorporated in future amendments. The project involves reconstruction of a T-150 building with various specific technical requirements around electrical, mechanical, and structural elements.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Lolo National Forest T-150 Building Reconstruction, 1240LU25R0018
08/08/2025 11:00 am
Additional submitted questions:
1. Is there any liquidated damages? No liquidated damages in this contract.
2. A403/ detail 1 grid 9 shows mop sink, grid 8 shows drinking fountain. Are these part of Option 2? If option 2 is not accepted, where do they go? Fitness and Restroom Areas shall be installed only if “Option Item 2 – Fitness and Restroom Areas” is selected. All infrastructure for option 2 is base bid. The mop sink and drinking fountain fixtures are associated with Option 2. Note: Option item numbering will be clarified in a future amendment.
3. A701 finish schedule calls out full size FRP. A403/ details 2-13 calls for 5’ FRP. Which is correct? Full size FRP is not required. See interior elevations on sheet A403 for layout and dimensions of FRP panels.
4. C101 calls for fence to remain / reuse. Correct
5. C106A calls for new fence and gates. Correct
6. C106 calls for new fence and Asphalt Correct
7. C108 has new fence details Correct
8. A011 Protect existing / Remove and relocate Correct see civil drawings
9. A101 / 1 Is new fence part of Option 1 or is it base bid? See dash line, and Civil drawings - Base bid
10. US Forestry T150 #1240LU25R0018, will this project need local building permits or will Forestry perform their on inspections? No local building permits required.
11. I am a local (Butte MT) manufacturer representative for several commercial building product lines. One of these is Drexel Metals a division of Carlisle Construction Materials. Drexel is a premier manufacturer of metal roofing and wall panels. I have had several qualified contractors reach out to me about this project expressing interest in using Drexel. I would like to formally request Drexel be added as an approved equal per addendum. Confirmed acceptable. The proposed metal roof panel product substitution will be added as a note into the applicable specifications section and then included in a future amendment.
12. Is there a Builders Risk required for Forestry T150 #1240LU25R0018? Builders Risk is not a requirement, bonding is required.
13. What the series of RLM Lighting is specified on fixtures E1E and E3 by TMS Lighting?
This is on E004. See responses below, 18 and 19.
14. Also, can you please verify if this project needs to meet BAA requirements? FAR Clause 52.225-11 Buy American Act-Construction Materials under Trade Agreements (NOV 2023) is included in this solicitation and impending contract.
15. I am looking at the ICT portion of this bid and have an RFI:
The legend and specs include security cameras, but I don't see any on the plans on the exchange. Is there another set of plans that includes cameras?
There are no cameras in this scope, just the infrastructure shown for future installation. Spec section 28 2300 is removed.
Installation of camera pathways shall be considered under option 1.
Bid items 27/28 will be added to SOI in a future amendment.
16. Who is responsible for the ACM panel in detail 4 of sheet A510? Is there an ACM panel spec that I am missing? ACM Panel not required - 1/8" alum plate with bend ends acceptable for infill panels. Color to match storefront.
17. Detail 1 on Sheet A510 shows SF3. I noticed that the jambs are drawn continuously.
I believe those jambs should not continue on past the head of each storefront bay.
We will provide pricing for three separate storefront openings per, with detail 4.
Correct, sections of storefront are not continuous at elevations see updated transition detail at jambs. These will be shown in a future the amendment.
Please see below regarding the lighting fixtures specified on this project:
18. Type E1E – Specified as TMS Lighting 0-19W-30K-120-W/M-XX. Fixture schedule description is 16” diameter RLM light ceiling mount at soffit but mounting is specified as surface wall mount. The attached specification sheet indicates that this is a wall mount fixture. I must confirm whether the mounting is ceiling mount rather than wall mount as that would require a custom mounting. If the attached spec sheet is the correct series, the catalog number should be prefaced with “4W.”
E1E fixtures are to be wall mounted, see elevations and plan drawings. Please use a wall type fixture for mounting (no custom mounting required). Updated cut sheet https://tmslighting.com/farm-light.html#wdetails for bidding 10W-O-15LED-30K-
120-WM-XX-
19. Types E3/E3E – Specified as TMS Lighting 0-16-19LED-C01-30K-120-XX. Fixture schedule description is 16” diameter RLM light surface mount at soffit. The attached specification sheet indicates that this is a ceiling pendant mount fixture. I must confirm whether the mounting is ceiling surface mount at the soffit or ceiling pendant mount as a ceiling mount would require a custom mounting. It is entirely possible that the specified 1” stem mount is interpreted as surface mount. If that is the case, no further clarification is need other than prefacing the catalog number with “NAU” per the attached spec sheet. Please see drawings for additional https://gcc02.safelinks.protection.outlook.com/?url=https%3A%2F%2Ftmslighting.com%2Ffarm-light.html%23wdetails&data=05%7C02%7Ctanner.grimstad%40usda.gov%7Cb01429c826ab45ebaf8b08ddd0693963%7Ced5b36e701ee4ebc867ee03cfa0d4697%7C1%7C0%7C638895872719461777%7CUnknown%7CTWFpbGZsb3d8eyJFbXB0eU1hcGkiOnRydWUsIlYiOiIwLjAuMDAwMCIsIlAiOiJXaW4zMiIsIkFOIjoiTWFpbCIsIldUIjoyfQ%3D%3D%7C0%7C%7C%7C&sdata=0sI2NFmg7mR5lq3U2EhgG8n%2Bf%2FulFhbKr%2FpxLwkjyT0%3D&reserved=0 references of the required mounting. These fixtures in those locations are intended with stem mount at soffit.
20. Types H1/H1E – Specified as Lithonia XIB-L24-30000LM-AVCL-MVOLT-GZ10-40K- 90CRI-UPL. The XIB high bay is a wet location high bay which seems unusual for mezzanine mounting. I would like to confirm whether this fixture really needs to be wet location listed. The exits mounted in the same area are not wet location, so that is another reason for my question. Wet location type is not required. Please use fixture IBE Non-Wet location High Bay.
21. Bid Option #2 vs. Bid Option #3 – Section 01 2300 lists Option Item No. 2 as Fitness and Restroom Areas (Rooms 104 – 108. Option Item No. 3 is Interior Fence Partitions. Note #8 on Sheet E103 states “shaded area is to be bid as Option Item
3. For Base Bid, simply continue the pattern of Type F1 luminaires from Storage Area 103 throughout this area.” From this description, I believe this is Option 2 rather than Option 3. Please clarify this for bidding purposes. Restrooms are option 2 so electrical notes are correct in designation of #2. The revised option numbering will be shown in a future amendment.
22. I'm reaching out to see if you know the color for the downspout adapter? Final finish colors are selected once physical samples of options are provided during submittal process. Design intent is to attempt to closely match the downspout and roof material color – METAL SALES - Old Zinc Grey (W29) is the reference. Note...but until final roofing color is selected a final color can not be selected to match.
23. Specification Section 105123 Lockers is included in the specifications. No lockers appear to be indicated in the plans. Is this specification required for the project?
No lockers in the project.
24. Specification Section 113013 Residential Appliances is included in the specifications. Sheet A110 indicates that these are to be provided and installed by Owner. Is the specification strictly for reference? Correct, this specification is only for reference.
25. Specification Section 133419 Metal Building Systems is included in the specifications. This appears to be a structural steel building and specification for all components of the building are included elsewhere. Should this Specification 133419 be deleted? Yes, division 13 should be deleted. In the near future a drawing amendment will be issued showing the updated option numbers on drawings and specifications.
26. Sheet A003; Ceiling Assemblies C1; States ‘(SSD) See Structural Drawings for sizes and spacing.’ Assembly also indicates 600S162-54 @ 16” OC. Structural plans do not contain these elements. Should we follow the 600S152-54 @ 16” OC? Yes, the 16” O.C. is a MINIMUM requirement.
27. Sheet A120; Reflected Ceiling Plan; Level 1 RCP; Lower right hand side: Calls for “Caged Ceiling 12’ AFF. See Structural Drawings (SSD).” Structural plans do indicate any of these elements. Please clarify for bidding purposes. Correct, this is not a structural condition. The intent is to use the same wire cage partition manufacturers system for the ceiling as the walls. Verify with cage partition manufacturer the shown span and area. Utilize their approved system for caging the ceiling secure.
28. Can you confirm this is a small business set-aside project? Yes
29. Can we get a copy of the site visit sign in sheet? This sign-in sheet was posted
8/4/25 on the solicitation link on SAM.gov.
30. Can you provide the existing building plans as .pdf files? SEE EXISTING T150
INSPECTION REPORT.
31. Can you clarify the Option Item numbering? There seems to be various plan sheets showing different numberings. For instance, Sheet A110 shows the Fitness / Restroom area as Option 3. Sheet A120 shows the ceiling clouds as Option 6.
Revised option numbering will be addressed in a future amendment.
32. Civil plans do not call for repair of existing lawn areas north of the building. Is this to be part of our scope? Is this area irrigated? Any sod removed for trenching will need to be replaced as well as irrigation lines and sprinkler heads prior to substantial completion. Any sod that is damaged for construction and is not included in the trench limits will need to be replaced prior to substantial completion.
33. 1/A101 calls out “landscaping gravel” north and east of the building, and “landscaping area” west of the building. Is all of this meant to be landscaping gravel as shown in 2/C107? Yes
34. Demolition note 1 on C101 calls out exploratory excavation for a potential water line. Are we to include only the exploratory excavation in our pricing? Or are we to assume there is a water line and include pricing for removing it? SEE DEMOLITION
NOTE 1 ON C101 FOR CLARIFICATION.
35. C102 has a 1”=30’ scale. Should this be 1” = 20’? Yes, the overall view on sheet C102 is at a 1”=20’ scale, the scale bar in the upper right hand corner of the page is incorrect.
36. Can you confirm if abatement is part of our scope? Specification 024100, 1.01A notes “excluding of hazardous materials”. Abatement is the responsibility of the contractor.
37. Can you clarify what work is being covered under specification 133419? It looks like the structure steel and framing are all under Division 5 specs. Division 13 is being removed in a future amendment.
38. There is a specification for lockers (105123), but I haven’t located any on the plans. Can you clarify where these occur? No lockers in project, locker specifications will be removed in future amended drawings.
39. Can you clarify the height of the Option 4 caged partition? Will be option 3 in future amended drawings, but height = 12’-0”
40. A601 includes a Type W wire cage door. I don’t see this occurring on the plan or in the schedule. Does this exist? CLARIFICATION: TYPE W DOOR NOT
REQUIRED. NO DOORS IN DOOR SCHEDULE ARE TYPE W.
41. A120 refers to structural plans for the caged ceiling. Can you clarify where this is on structural plans? CLARIFICATION, this is not a structural condition. The intent is to use the same wire cage partition manufacturers system for the ceiling as the walls. Verify with cage partition manufacturer the shown span and area. Utilize their approved system for caging the ceiling secure.
42. Can you provide a size for door 102? THIS SIZE WILL DEPEND ON MFR
CAPABILITIES. OUR REQUESTED SIZE IS 6’-0” W X 7’-0” H. PLEASE PLAN FOR
CAGED PARTITION TO ALLOW SLIDING DOOR TO MOVE FREELY PAST T150
COLUMN @ INTERSECTION OF GRIDS 10 & D.
43. The Accessories Legend on A403 show Baby Changing Stations but it is not called out in the spec. Are these owner furnished or do you have a basis of design? No changing stations required see sheet A403.
44. There are Shower Benches shown on the plans but it is not included in the spec. Is this included in the Shower Enclosure or do you have a basis of design? No accessories spec, these are built-ins.
45. Are the Shower Grab Bars included in the Shower Enclosure Bid or should these be included in the Toilet Accessories Bid? Grab bars required for showers.
46. I am not seeing Lockers on the plans. Can you please advise? No lockers required, locker specifications will be removed in future amended drawings.
47. I've noticed on the exterior elevations that there are two different shaded areas stating "insulated wall panels" (specifically elevation #1 & #4) , which contradicts the materials legend. May I please get clarification on this? The elevations had shading turned on and that made it hard to tell what the material was in shadow.
The shading was turned off and a revised sheet A201 will be issued in future amended drawings.
Questions added as of 8/12/2025
48. Is new fence and gates an option? There are new fence sections and gates required in base bid and option 1. See A101, C101, C103, C104, C106, C106A.
49. Is the existing fence to remain and reuse an option? Base Bid has areas of fencing to remain and new sections in the areas noted closer to the building. In option 1 the remaining existing fencing is replaced with new specified fencing and gates as noted on drawings.
50. The scheduling description in L.2.b.iii of the solicitation references two phases for the project. Can you clarify this? I haven’t seen anything on the plans showing phasing. This section of the solicitation is removed by amendment 001.
51. We received the supplemental documents posted to the solicitation on August 4th.
Are these going to be incorporated into an amendment? How do you want us to acknowledge them on Form 1442? The DCI inspection report will not be included in an amendment as it does not change the solicitation or specs/plans. Please reference solicitation attachment as part of the Q&A posting.
52. Plan sheet A000 describes Option 1 as everything beyond 5’ of the building footprint.
I’m assuming this is incorrect, and we are using sheet A101 to define the site option.
Please reference civil sheets for majority of detail to option 1.
53. Sheet A003 / assembly RA1 shows perpendicular rows of treated furring strips.
What is the spacing of these? Perpendicular furring strips occur @ every roof panel clip (per roof manufacturer). 16” O.C. spacing for the vertical furring strips.
54. Is the historic marker shown on A101 being provided by the government? There’s not much detail on how this is fabricated. Coordinate design w/ C.O. Intent is to match existing Fort signage.
55. 4/A510 shows an ACM panel at the storefront assembly. Is there a material spec for this? See updated details provided.
56. What are the finish requirements for the reclaimed wood accent wall and ceiling panels? Boards are to be in good usable condition. No rot and all existing fasteners to be removed prior to reuse. Clean and finish with clear finish. Intent is to preserve and protect the reclaimed wood.
57. 4/S501 calls out 6” of gravel under slabs; 8.2.2 of the Geotech report calls for 4”.
Please clarify which is correct. 6" is the structural requirements
58. P102 shows two floor sinks in room 110 that are vented through a wall being building with Option 2. How are these to be vented under the base bid? There is only one floor sink in the project – MS-1. This mop sink is associated with Option Item 2 – Fitness and Restroom Areas. If Option Item 2 is selected, then that includes the mop sink and associated venting.
59. M101 shows supply ductwork in room 103 that’s being fed from the Option 2 system. Should room 103 be included in Option 2 as well? Please see Key Note #8 on M101 for clarification.
60. As a supplier, do I need to register for a SAM Id? No, only the prime contractor needs to be registered in SAM.gov have a UEI number.
Please all see attachments for additional clarifications:
1. Arcadia substitution request (approved). Will be included in the future amended specifications.
2. Drexel substitution request (approved). Will be included in the future amended specifications.
3. C.H.I. coiling door substitution request (approved). Will be included in the future amended specifications. V1
4. OCC CAT6 substitution request (approved). Will be included in the amended specifications. V2
5. OCC fiber substitution request (approved). Will be included in the amended specifications. V2
FORTETM PENDANT
QUANTITY:
TYPE:
PROJECT:
APPLICATION • PENDANT MOUNT
• INDOOR OR OUTDOOR RATED
APPLICATION • PENDANT MOUNT
• INDOOR OR OUTDOOR RATED
PN: FOR
FINISHES • AVAILABLE IN SEVERAL TMS SPECIALTY, AND
POWDER COATED FINISHES
• CUSTOM RAL FINISHES AVAILABLE
FINISHES • AVAILABLE IN SEVERAL TMS SPECIALTY, AND
POWDER COATED FINISHES
• CUSTOM RAL FINISHES AVAILABLE
DIMMING • 0 - 10V STANDARD DIMMINGDIMMING • 0 - 10V STANDARD DIMMING
WEIGHT • 4.6 LBS MAXIMUM WEIGHT • 4.6 LBS MAXIMUM
ILLUMINATION • DIRECT
• LED 90CRI
• 995 - 1,887 LUMENS
ILLUMINATION • DIRECT
• LED 90CRI
• 995 - 1,887 LUMENS
ELECTRICAL • 120V, 277V AND 347V
• 10kA SURGE SUPRESSION STANDARD
ELECTRICAL • 120V, 277V AND 347V
• 10kA SURGE SUPRESSION STANDARD DIFFUSERS • CLEAR OR FROSTED, TEMPERED GLASS GLOBEDIFFUSERS • CLEAR OR FROSTED, TEMPERED GLASS GLOBE
MOUNTING • 120” (305CM) BLACK OR WHITE DROP CORD
W/ AIRCRAFT CABLE (OPTIONAL)
• 1“ TO 60” (2.5CM TO 152CM) STEM MOUNT
MOUNTING • 120” (305CM) BLACK OR WHITE DROP CORD
W/ AIRCRAFT CABLE (OPTIONAL)
• 1“ TO 60” (2.5CM TO 152CM) STEM MOUNT
CONSTRUCTION • ALUMINUM, BRUSHED COPPER OR STEELCONSTRUCTION • ALUMINUM, BRUSHED COPPER OR STEEL
DIMENSION • 12”, 14” 16“ (31CM, 36CM, 41CM)DIMENSION • 12”, 14” 16“ (31CM, 36CM, 41CM)
DIRECT
100W
100IN
15W
1342 1108
15LED
17W
17LED
19W
19LED
FORTETM PENDANT
QUANTITY:
TYPE:
PROJECT:
FOR
120V
VOLTAGE
277V
347V
100IN
100W 100W15W
995 1109
15LED 100IN
15W
1144 1109
15LED
17W
17LED
19W
19LEDILLUMINATION1
LED (W)
LUMENS
3.
CRD C01 C06 C12 C18 C24 C36 C48 C60
MOUNTING
4.
12”DIA. (31CM)
14”DIA. (36CM)
16”DIA. (41CM)
DIAMETER
2.
1 8765 12 1311109432
OUTDOOR
O
APPLICATION
1.
INDOOR
I
NOTE: SOME OPTIONS MAY NOT BE COMPATIBLE WITH OTHERS. ALL SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. CONTACT TMS LIGHTING FOR UPDATED SPECIFICATIONS.
NONE
12” (31CM) WIRED GUARD
W12
14” (36CM) WIRED GUARD
W14
16” (41CM) WIRED GUARD
W1613.
LED DIMMING (0 - 10V, CURRENT - SINKING)
DIML
NONE
DIMMING
10.
FROSTED
GLOBE
G2
CLEAR, ELONGATED
GLOBE WITH CAST GUARD
G11
NONE
GLOBE/
LENS
9.
CLEAR, ELONGATED
GLOBE
G1
CEILING SLOPE ADAPTER
FOR STEM MOUNT (30°)
BL
AIRCRAFT CABLE
FOR DROP CORDS
ACC
NONE
MOUNTING5
ACCESSORIES
WIRE GUARD
12.
INTEGRAL
EM
NONE
REMOTE
EMR
REMOTE COLD PACK
EMCR
INTEGRAL COLD PACK
EMC
EMERGENCY4
11.
2. GLOBES AND EMERGENCY ARE NOT AVAILABLE WITH THE 17W LED PAR 38 LAMPS
4. 10W AT 90 MINUTES. EMERGENCY OPTION IS ONLY AVAILABLE IN 120 - 277V SYSTEMS
3. A CLEAR COAT IS APPLIED TO COPPER. PATINA WILL FORM OVER TIME
5. MAY REQUIRE TO COMPLY WITH LOCAL SEISMIC/EARTHQUAKE CODE
1. 12” IS ONLY AVAILABLE FOR 100IN AND 15LED
120”(305CM)
DROP CORD
1”(2.5CM)
STEM MOUNT
6”(15CM)
STEM MOUNT
12”(31CM)
STEM MOUNT
18”(46CM)
STEM MOUNT
24”(61CM)
STEM MOUNT
36”(91CM)
STEM MOUNT
48”(122CM)
STEM MOUNT
60”(152CM)
STEM MOUNT
35K
40K
NONE
LED CCT
6.
30K
BLACK DROP CORD
BC
NONE
CORD
5.
WHITE DROP CORD
WC
FINISH3
8.
ADDITIONAL AND PREMIUM FINISHES
AVAILABLE. SEE FINISHES CHART MATTE
WHITE
F04
GLOSS
WHITE
F05
MATTE
BLACK
F15
GLOSS
BLACK
F16
PEWTER
F09
SILVER
METALLIC
F31
SATIN
ALUMINUM
F18
DROP CORD MOUNT STEM MOUNT
FOR - 12”
3.4LB
FOR - 16”
4.6LB
FOR - 14”
4LB
6.25” (15.8CM)
ø12”DIA (30CM) ø14”DIA (35CM) ø16”DIA (40.8CM)
7.18” (18CM) 8” (20CM)
3”(8CM)
REMOTE DRIVER ENCLOSURE REMOTE DRIVER ENCLOSURE
3”(8CM) 3”(8CM)
H
DIADIA
ADJUSTABLE DROP CORD
120”(305CM) MAX.
INCLUDED
H
AIRCRAFT CABLE
120”(305CM)
H
DIA
STEM MOUNT
60”(152CM) MAX.
SPECIFY LENGTH
REMOTE DRIVER ENCLOSURE
DROP CORD MOUNT
W/AIRCRAFT CABLE
POWER CORD
NOTE: THIS FIXTURE CAN BE CUSTOMIZE. DIMENSION, LAMP TYPES, ENCLOSURE, AND COLOR CAN BE MODIFIED TO SUIT YOUR LIGHTING AND ARCHITECTURAL REQUIREMENTS. CONTACT YOUR LOCAL REPRESENTATIVE FOR MORE DETAILS: https://tmslighting.com/sales-agents.html
CUSTOM
PN
FOR
100INC
15LED
FORTETM PENDANT
LUMINAIRE LUMENS 995
TOTAL LUMINAIRE EFFICIENCY 58%
LUMINAIRE EFFICACY RATING 10
TOTAL LUMINAIRE WATTS 100
LUMINAIRE LUMENS 1887
TOTAL LUMINAIRE EFFICIENCY NA
LUMINAIRE EFFICACY RATING 87
TOTAL LUMINAIRE WATTS 22
WATTAGELUMENSSIZE (DIA) ILLUMINATION
100INC
IES INDOOR REPORT
PHOTOMETRIC FILENAME : FOR 16 19LED.IES
POLAR GRAPH
IES INDOOR REPORT
PHOTOMETRIC FILENAME : FOR 12 100IN.IES
POLAR GRAPH
DIRECT
100INC 100
15LED
15LED
19LED
19LED
MAXIMUM CANDELA = 309.726 LOCATED AT HORIZONTAL ANGLE = 90, VERTICAL ANGLE = 5
# 1 - VERTICAL PLANE THROUGH HORIZONTAL ANGLES (90 - 270)
# 2 - VERTICAL PLANE THROUGH HORIZONTAL ANGLES (0 - 180)
MAXIMUM CANDELA = 51353.46 LOCATED AT HORIZONTAL ANGLE = 0, VERTICAL ANGLE = 0
# 1 - VERTICAL PLANE THROUGH HORIZONTAL ANGLES (90 - 270)
# 2 - VERTICAL PLANE THROUGH HORIZONTAL ANGLES (0 - 180)
80 1300
DISPLAYED FINISHES DIFFER BETWEEN SCREENS AS WELL AS PRINTERS AND MAY NOT ACCURATELY DEPICT COLOR.
FINISHES ARE SUBJECT TO AVAILABLILITY AND MAY NOT BE APPLICABLE TO ALL FIXTURES OR FOR QUICKSHIP.
NOTE: ALL FINISHES NOT MARKED WITH NOTATION (1) ARE APPLIED TO THE EXTERIOR ONLY. THE INTERIOR WILL BE F05 GLOSS WHITE.
MATTE FINISHES AVAILABLE. CONSULT FACTORY.
F04
MATTE
WHITE
FINISHES
F09
PEWTER
F05
GLOSS
WHITE
F15
MATTE
BLACK
F16
GLOSS
BLACK
F311
SILVER
METALLIC
F41
ELECTRIC
PURPLE
F18
SATIN
ALUMINUM
F40
BUBBLE
PINK
F10
FIRE
RED
F08
MIDNIGHT
BLUE
F45
COPPER
METALLIC
F39
AQUA
BLUE
F13
FOREST
GREEN
F38
MEADOW
GREEN
F06
CLAY
BROWN
F14
SUNSHINE
YELLOW
F11
CITRUS
ORANGE
F281
DARK
CHAMPAGNE
F221
HARVEST
GOLD
F331
PYRITE
BRONZE
F261
MELTED
COPPER
F07
ZEUS
BROWN
F21
ARCH
BRONZE
F321
BRONZE
METALLIC
F251
MELTED
GOLD
F241
MELTED
PLATINUM
RAL
CUSTOM
(RAL #)
F441
FAUX
COPPER
F431
FAUX
GOLD
F421
FAUX
CHROME
PREMIUM FINISHES
PREMIUM MATERIALS
BR1 2
BRUSHED
ALUMINUM
AN1 2
ANODIZED
SS1 2
STAINLESS
STEEL
CO1 2
SOLID
COPPER
2: MATERIALS ARE CONSISTENT (INTERIOR & EXTERIOR). STEMS AND CANOPIES WILL BE F16 GLOSS BLACK.
1: FINISHES IS APPLIED TO THE INTERIOR AND EXTERIOR OF THE FIXTURE.
FARM LIGHTTM WALL
QUANTITY:
TYPE:
PROJECT:
APPLICATION • WALL MOUNT
• INDOOR OR OUTDOOR RATED
APPLICATION • WALL MOUNT
• INDOOR OR OUTDOOR RATED
PN: 10W
FINISHES • AVAILABLE ANODIZED, BRUSHED, AND IN SEVERAL TMS
POWDER COATED FINISHES
• CUSTOM RAL FINISHES AVAILABLE
FINISHES • AVAILABLE ANODIZED, BRUSHED, AND IN SEVERAL TMS
POWDER COATED FINISHES
• CUSTOM RAL FINISHES AVAILABLE
DIMMING • 0 - 10V STANDARD DIMMINGDIMMING • 0 - 10V STANDARD DIMMING
WEIGHT • 2.5 LBS MAXIMUMWEIGHT • 2.5 LBS MAXIMUM
ELECTRICAL • 120V, 277V AND 347V
• 10kA SURGE SUPRESSION STANDARD
ELECTRICAL • 120V, 277V AND 347V
• 10kA SURGE SUPRESSION STANDARD
DIFFUSERS • HIGH EFFICIENCY ACRYLICDIFFUSERS • HIGH EFFICIENCY ACRYLIC
MOUNTING • WALL, MOUNTED TO A 4”(10CM) J-BOXMOUNTING • WALL, MOUNTED TO A 4”(10CM) J-BOX
CONSTRUCTION • ALUMINUMCONSTRUCTION • ALUMINUM
DIRECT
DIMENSION • 12”DIA (30CM)DIMENSION • 12”DIA (30CM)
DRIVER • WALL MOUNT (INTEGRAL)
• REMOTE MOUNT (INDOOR OR OUTDOOR)
DRIVER • WALL MOUNT (INTEGRAL)
• REMOTE MOUNT (INDOOR OR OUTDOOR)
ILLUMINATION • DIRECT
• LED 90CRI
• INCANDESCENT MEDIUM BASE SOCKET
• 753 - 1602 LUMENS
ILLUMINATION • DIRECT
• LED 90CRI
• INCANDESCENT MEDIUM BASE SOCKET
• 753 - 1602 LUMENS
https://tmslighting.com/farm-light.html https://tmslighting.com/farm-light.html https://tmslighting.com/home.html
EMERGENCY2
QUANTITY:
TYPE:
PROJECT:
10W
NOTE: SOME OPTIONS MAY NOT BE COMPATIBLE WITH OTHERS. ALL SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. CONTACT TMS LIGHTING FOR UPDATED SPECIFICATIONS.
INDOOR
I
OUTDOOR
O
APPLICATION
1.
FINISH1
6.
----8.
NONE INTEGRAL
EM
INTEGRAL
COLD PACK
EMC
REMOTE
EMR
REMOTE
COLD PACK
EMCR
NONE
DIMMING
7.
LED DIMMING (0 - 10V, CURRENT - SINKING)
DIML
120V
VOLTAGE
4.
277V
347V
150W
150IN
ILLUMINATION
LED (W)
2.
15W
2240LUMENS 1090
15LED
NONE
WALL MOUNT
(INTEGRAL)
WM
REMOTE INDOOR MOUNT
(NEMA 1)
N1
REMOTE OUTDOOR MOUNT
(NEMA 4)
N4
DRIVER
5.
1 8 9765432
WIRE
GUARD
----9.
NONE
W12
12”
WIRE GUARD
1. WALL PLATE OR DRIVER ENCLOSURE, CONDUIT, AND TOP CAP ARE ALWAYS IN “F18-SATIN ALUMINUM” FINISH. SEE FINISH CHART FOR REFLECTOR.
2. 10W AT 90 MINUTES. EMERGENCY OPTION IS ONLY AVAILABLE IN 120 - 277V SYSTEMS
4000K
40K
3000K
30K
NONE
LED CCT
3.
3500K
35K
BRUSHED
ALUMINUM
BR
ANODIZED
AN
FAUX
GOLD
F43
FAUX
COPPER
F44
COPPER
METALLIC
F45
CUSTOM
(SPECIFY RAL)
RAL
BUBBLE
PINK
F40
ELECTRIC
PURPLE
F41
FAUX
CHROME
F42
MELTED
GOLD
F25
MELTED
COPPER
F26
PYRITE
BRONZE
F33
DARK
CAMPAGNE
F28
BRONZE
METALLIC
F32
AQUA
BLUE
F39
MEADOW
GREEN
F38
ARCH.
BRONZE
F21
HARVEST
GOLD
F22
MELTED
PLATINUM
F24
CLAY
BROWN
F06
ZEUS
BROWN
F07
CITRUS
ORANGE
F11
MIDNIGHT
BLUE
F08
FIRE
RED
F10
SUNSHINE
YELLOW
F14
FOREST
GREEN
F13
MATTE
WHITE
F04
GLOSS
WHITE
F05
PEWTER
F09
MATTE
BLACK
F15
GLOSS
BLACK
F16
SATIN
ALUMINUM
F18
SILVER
METALLIC
F31 https://tmslighting.com/farm-light.html
10W
5.75”(15CM)
7.5”(19CM)
12”
(30.5CM)
3.36”
(8.5CM)
19.9(50.5CM)
INTEGRAL LED DRIVER
PROFILE
NOTE: THIS FIXTURE CAN BE CUSTOMIZE. DIMENSION, LAMP TYPES, ENCLOSURE, AND COLOR CAN BE MODIFIED TO SUIT YOUR LIGHTING AND ARCHITECTURAL REQUIREMENTS. CONTACT YOUR LOCAL REPRESENTATIVE FOR MORE DETAILS: https://tmslighting.com/sales-agents.html
CUSTOM
PN
10W
FARM LIGHTTM WALL
LUMINAIRE LUMENS 1090
TOTAL LUMINAIRE EFFICIENCY NA
LUMINAIRE EFFICACY RATING 64
TOTAL LUMINAIRE WATTS 17
LUMINAIRE LUMENS 2240
TOTAL LUMINAIRE EFFICIENCY 84%
LUMINAIRE EFFICACY RATING 15
TOTAL LUMINAIRE WATTS 150
WATTAGELUMENSILLUMINATION
15LED
150IN
MAXIMUM CANDELA = 1078.77 LOCATED AT HORIZONTAL ANGLE = 0, VERTICAL ANGLE = 0
# 1 - VERTICAL PLANE THROUGH HORIZONTAL ANGLES (90 - 270)
# 2 - VERTICAL PLANE THROUGH HORIZONTAL ANGLES (0 - 180)
# 3 - HORIZONTAL CONE THROUGH VERTICAL ANGLE (90)
MAXIMUM CANDELA = 613.755 LOCATED AT HORIZONTAL ANGLE = 45, VERTICAL ANGLE = 5
# 1 - VERTICAL PLANE THROUGH HORIZONTAL ANGLES (90 - 270)
# 2 - VERTICAL PLANE THROUGH HORIZONTAL ANGLES (0 - 180)
IES INDOOR REPORT
PHOTOMETRIC FILENAME : 10W 150IN.IES
POLAR GRAPH
IES INDOOR REPORT
PHOTOMETRIC FILENAME : 10W 15LED F05.IES
POLAR GRAPH
DIRECT
AN1 2
ANODIZED
F04
MATTE
WHITE
FINISHES
F09
PEWTER
F05
GLOSS
WHITE
F15
MATTE
BLACK
F16
GLOSS
BLACK
F311
SILVER
METALLIC
F41
ELECTRIC
PURPLE
F18
SATIN
ALUMINUM
F40
BUBBLE
PINK
F10
FIRE
RED
F08
MIDNIGHT
BLUE
F45
COPPER
METALLIC
F39
AQUA
BLUE
F13
FOREST
GREEN
F38
MEADOW
GREEN
F06
CLAY
BROWN
F14
SUNSHINE
YELLOW
F11
CITRUS
ORANGE
F281
DARK
CHAMPAGNE
F221
HARVEST
GOLD
F331
PYRITE
BRONZE
F261
MELTED
COPPER
F07
ZEUS
BROWN
F21
ARCH
BRONZE
F321
BRONZE
METALLIC
F251
MELTED
GOLD
F241
MELTED
PLATINUM
F441
FAUX
COPPER
F431
FAUX
GOLD
F421
FAUX
CHROME
RAL
CUSTOM
(RAL #)
PREMIUM FINISHES
PREMIUM MATERIALS
BR1 2
BRUSHED
ALUMINUM
DISPLAYED FINISHES DIFFER BETWEEN SCREENS AS WELL AS PRINTERS AND MAY NOT ACCURATELY DEPICT COLOR.
FINISHES ARE SUBJECT TO AVAILABLILITY AND MAY NOT BE APPLICABLE TO ALL FIXTURES OR FOR QUICKSHIP.
NOTE: ALL FINISHES NOT MARKED WITH NOTATION (1) ARE APPLIED TO THE EXTERIOR ONLY. THE INTERIOR WILL BE F05 GLOSS WHITE.
MATTE FINISHES AVAILABLE. CONSULT FACTORY.
2: MATERIALS ARE CONSISTENT (INTERIOR & EXTERIOR). STEMS AND CANOPIES WILL BE F16 GLOSS BLACK.
1: FINISHES IS APPLIED TO THE INTERIOR AND EXTERIOR OF THE FIXTURE.
FARM LIGHTTM WALL
History: ☐ New product ☐ 1-4 years old ☐ 5-10 years old ☐ More than 10 years old
Differences between proposed substitution and specified product:
☐ Point-by-point comparative data attached — REQUIRED BY A/E
Similar Installation:
SUBSTITUTION
R EQUEST
( After t he Bidding/Negotiating Phase)
Project:
To :
Re:
Substitution Request Number:
From:
Da te:
A /E Project Number:
Contract For:
Specification Title:
Section: Page:
De scription:
Ar ticle/Paragraph:
Proposed Substitution:
Address: Manufacturer: Phone:
Trade Na me: Model No.:
In Address: staller: Phone:
Reason for not providing specified item:
Project: Architect:
Addre ss: Owner:
Da te Installed:
Proposed substitution affects other parts of Work: ☐ No ☐ Yes; explain
. ) Savings to Owner for accepting substitution: ( $
Proposed substitution changes Contract Time: ☐ No ☐ Yes [Add] days. Deduct] [
Supporting Data Attached: ☐ Drawings ☐ Product Data ☐ Samples ☐ Tests ☐ Reports ☐
Gretchen Text Box Region One Forest Service
Gretchen Text Box Morrison Maierle
Gretchen Text Box Communication resources
Gretchen Text Box 8/07/2025
Gretchen Text Box Category 6 twisted pair cable
Gretchen Text Box 2.02
Gretchen Text Box 27 1513-2
Gretchen Text Box
OCC
Gretchen Text Box OCC cat 6 cable
Gretchen Text Box 5290 Concourse Drive Roanoke, VA 24019 USA
Gretchen Text Box 800-622-7711
Gretchen Text Box X
Gretchen Text Box same performance, potential cost savings.
Gretchen Text Box cost savings
THIRD
ANGLE
PROJECTION
B
MATERIAL
FILENAME
DATE
NEXT DWG
PREVIOUS DWG
APPROVED
ENGINEER
CHECKED
DRAWN
SHEETSCALE:
REVDWG NO.SIZE
DWG TITLE
CRITICAL DIMENSION CODE
= FUNCTION
DATE
DATE
DATE
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES.
TOLERANCES:
FINISH
F M A
= MATING
= AUDIT NONE 1 OF 1
THIS DRAWING AND THE DESIGN SHOWN ARE THE
PROPERTY OF OPTICAL CABLE CORPORATION AND
MAY NOT BE USED AS THE BASIS FOR MANUFACTURE
OR SALE WITHOUT SPECIFIC WRITTEN PERMISSION
OF OPTICAL CABLE CORPORATION.
33 Superior Way Swannanoa, NC 28778 Phone: 828-298-2260 Fax: 828-298-2487 www.occfiber.com
1. DESCRIPTION: CATEGORY 6 CABLE, CONSISTING OF 4 PAIRS, 23 AWG,
UNSHIELDED WITH A PVC JKT. CMR, c(UL)us TYPE FT4 PER UL 444.
PACKAGING TYPE: BOX
2. CONDUCTOR: 23 AWG SOLID BARE COPPER (.0224" NOM OD)
INSULATION: POLYETHYLENE .039" NOM OD, .0085" AVG WALL
3. PAIRING: COLOR CODED CONDUCTORS ARE TWISTED INTO PAIRS WITH
VARYING LAYS TO MINIMIZE CROSSTALK.
PAIR # COLOR
1 BLU PAIRED WITH WHT/BLU
2 ORG PAIRED WITH WHT/ORG
3 GRN PAIRED WITH WHT/GRN
4 BRN PAIRED WITH WHT/BRN
4. CABLING: THE FOUR (4) TWISTED PAIRS ARE CABLED TOGETHER WITH A
VARYING LAYS WITHIN THE OUTER JACKET WITH A TAPE SEPARATOR.
5. OVERALL JACKET: LOW SMOKE PVC, SEE COLOR TABLE FOR CABLE COLOR.
.220" NOM OD
.020" AVG WALL THICKNESS
6. MARKING: THE CABLE IS TO BE MARKED WITH THE FOLLOWING PRINT
LEGEND:
OCC (WWW.OCCFIBER.COM) P/N OCC-UE64R --- ETL
VERIFIED CATEGORY 6 4 PR 23 AWG CMR C(UL)US OCCV
E322888 MADE IN USA MYLLDDS XXXXX FT
WHERE: MYLLDDS = TRACEABILITY CODE
XXXXX FT = SEQUENTIAL FOOTAGE MARKINGS
7. AGENCY APPROVAL: UNDERWRITERS LABORATORIES. INC. TYPE CMR,
COMMUNICATIONS RISER CABLE, LISTED AS BEING SUITABLE FOR USE IN
VERTICLE RUN IN A SHAFT OR FROM FLOOR TO FLOOR PER UL 444. ALSO LISTED
AS HAVING ADEQUATE FIRE-RESISTANT CHARACTERISTICS CAPABLE OF
PREVENTING THE CARRYING OF FIRE FROM FLOOR TO FLOOR, IN ACCORDANCE
WITH ARTICLE 800 OF THE NATIONAL ELECTRICAL CODE.
8. CATEGORY 6 WORST CASE ELECTRICAL CHARACTERISTICS * :
CHARACTERISTIC IMPEDANCE: 100 ± 15 Ω (1 TO 250 MHz.)
MAXIMUM CONDUCTOR RESISTANCE: 6.6 Ω/100 METERS @ 20°C
MAXIMUM RESISTANCE UNBALANCED: 5%
MAXIMUM MUTUAL CAPACITANCE: 4.6 nF/100 METERS @ 1kHz.
MAXIMUM CAPACITANCE UNBALANCED: 330 pF/100 METERS MAXIMUM DELAY SKEW: 45 ns/100 METERS
NOMINAL VELOCITY OF PROPAGATION: 70%
STORAGE TEMPERATURE RANGE: N/A
INSTALLATION TEMPERATURE RANGE: 0°C +60°C
OPERATING TEMPERATURE RANGE: -20°C +60°C
* DISCRETE VALUES ARE FOR INFORMATION ONLY. EQUATIONS FOR SWEPT
FREQUENCIES GOVERN LIMITS. VERIFIED TO MEET CAT 6 TIA/EIA-568-C.2
PERFORMANCE REQUIREMENTS PER THE VERIFICATION REQUIREMENTS
DEFINED IN SUPPLIERS UL/ETL FILE(S).
9. PRODUCT APPROVAL REQUIRES CERTIFICATION OF COMPLIANCE TO
E.U. RoHS DIRECTIVE 2002/95/EC
E C110783E.dft
FRACTIONS ±1/32"
ANGLES ±1/2°
3 PLACE DECIMALS ±.005"
2 PLACE DECIMALS ±.01"
C110783 7/14/11
CABLE, CAT 6+,
23 AWG, 4 PR, UTP, CMRJ.YANIK
7/14/11D.A.HOLBERT
THIS CABLE SHALL BE COMPLIANT TO TIA-568.2 FOR CATEGORY 6.
7/14/11J.HOWESEE NOTES AND TABLES
SEE NOTES AND TABLES
J.CALLOWAY 12/10/20
ELECTRICAL PERFORMANCESPECIFICATIONS
OUTER JACKET
FR PVC
PAIR INSULATION
PE
23 AWG SOLID COPPER
SEPARATOR TAPE
Frequency
(MHz.) TIA Std Typical TIA Std Typical TIA Std Typical TIA Std Typical TIA Std Typical TIA Std Typical TIA Std Typical TIA Std Typical 1 2 1.8 74.3 89 72.3 87.2 72.3 87 70.3 85.2 67.8 83.1 64.8 81.1 20 31 4 3.8 3.6 65.3 79.3 61.5 75.7 63.3 77.3 59.5 73.7 55.8 70.6 52.8 68.6 23 29 8 5.3 5.1 60.8 74.5 55.4 69.4 58.8 72.5 53.4 67.4 49.7 64.4 46.7 62.4 24.5 33.3 10 6 5.8 59.3 72.9 53.3 67.1 57.3 70.9 51.3 65.1 47.8 62.4 44.8 60.4 25 33.9 16 7.6 7.4 56.2 69.6 48.7 62.2 54.2 67.6 46.7 60.2 43.7 58.2 40.7 56.2 25 34.2 20 8.5 8.3 54.8 68.1 46.3 59.8 52.8 66.1 44.3 57.8 41.8 56.2 38.8 54.2 25 34 25 9.5 9.3 53.3 66.5 43.8 57.2 51.3 64.5 41.8 55.2 39.8 54.1 36.8 52.1 24.3 35.1
31.25 10.7 10.4 51.9 64.9 41.2 54.5 49.9 62.9 39.2 52.5 37.9 52.1 34.9 50.1 23.6 34.5
62.5 15.4 15 47.4 60.1 32 45.1 45.4 58.1 30 43.1 31.9 45.9 28.9 43.9 21.5 32.2 100 19.8 19.1 44.3 56.8 24.5 37.7 42.3 54.8 22.5 35.7 27.8 41.7 24.8 39.7 20.1 30.6 155 25.2 24 41.4 53.7 16.3 29.7 39.4 51.7 14.3 27.7 24 37.7 21 35.7 18.8 29.2 200 29 27.3 39.8 52 10.8 24.7 37.8 50 8.8 22.7 21.8 35.4 18.8 33.4 18 28.3 250 32.8 30.7 38.3 50.4 5.5 19.7 36.3 48.4 3.5 17.7 19.8 33.4 16.8 31.4 17.3 27.6 300 33.7 49.1 15.4 47.1 13.4 31.8 29.8 27 350 36.6 48 11.4 46 9.4 30.4 28.4 26.5 400 39.2 47.1 7.9 45.1 5.9 29.2 27.2 26.1
500 44 45.5 1.5 43.5 NS 27.2 25.2 25.3
ACRF MIN.
(dB)
PSACRF MIN.
(dB)
RL MIN.
(dB)
INSERTION LOSS
MAX. (dB/100 m)
NEXT LOSS MIN.
(dB)
ACR MIN.
(dB)
PSNEXT LOSS MIN.
(dB)
PSACR MIN.
(dB)
UNCONTROLLED COPY
"OPTICAL CABLE CORPORATION (OCC)
RESERVES THE RIGHT TO REVISE ANY
AND ALL DESIGN SPECIFICATIONS."
OCC-UE64R-03
OCC-UE64R-02
OCC-UE64R-01 YELLOW
GRAY
GREEN
JACKET COLOROCC PART NUMBER
CABLE COLOR TABLE
OCC-UE64R-06
OCC-UE64R-05
OCC-UE64R-04
ORANGE
BLUE
WHITE
OCC-UE64R-09
OCC-UE64R-08
OCC-UE64R-07
VIOLET
RED
BLACK
History: ☐ New product ☐ 1-4 years old ☐ 5-10 years old ☐ More than 10 years old
Differences between proposed substitution and specified product:
☐ Point-by-point comparative data attached — REQUIRED BY A/E
Similar Installation:
SUBSTITUTION
R EQUEST
( After t he Bidding/Negotiating Phase)
Project:
To :
Re:
Substitution Request Number:
From:
Da te:
A /E Project Number:
Contract For:
Specification Title:
Section: Page:
De scription:
Ar ticle/Paragraph:
Proposed Substitution:
Address: Manufacturer: Phone:
Trade Na me: Model No.:
In Address: staller: Phone:
Reason for not providing specified item:
Project: Architect:
Addre ss: Owner:
Da te Installed:
Proposed substitution affects other parts of Work: ☐ No ☐ Yes; explain
. ) Savings to Owner for accepting substitution: ( $
Proposed substitution changes Contract Time: ☐ No ☐ Yes [Add] days. Deduct] [
Supporting Data Attached: ☐ Drawings ☐ Product Data ☐ Samples ☐ Tests ☐ Reports ☐
Gretchen Text Box Region One Forest Service
Gretchen Text Box Morrison Maierle
Gretchen Text Box Communication resources
Gretchen Text Box 8/07/2025
Gretchen Text Box Indoor outdoor fiber
Gretchen Text Box 2.02
Gretchen Text Box 27 1323-2
Gretchen Text Box
OCC
Gretchen Text Box OCC fiber
Gretchen Text Box 5290 Concourse Drive Roanoke, VA 24019 USA
Gretchen Text Box 800-622-7711
Gretchen Text Box X
Gretchen Text Box same performance, potential cost savings.
Gretchen cost savings
DZ-SERIES PLENUM INDOOR/OUTDOOR
ALUMINUM INTERLOCKING ARMORED SPECIFICATIONS
CABLE CHARACTERISTICS
JACKET COLOR Aqua, Black, Orange, or Yellow
JACKET MATERIAL Indoor / Outdoor Low Smoke PVC
BUFFER MATERIAL Low Smoke PVC
MECHANICAL AND ENVIRONMENTAL CHARACTERISTICS
MECHANICAL PERFORMANCE PERFORMANCE ICEA S-104-696
FLEX RESISTANCE 25 CYCLES
CRUSH RESISITANCE 650 N/CM
OPERATING TEMPERATURE -40OC to +70OC
STORAGE TEMPERATURE -40OC to +70OC
INSTALLATION TEMPERATURE (ACTUAL
TEMPERATURE OF CABLE)
0OC to +60OC
FLAME RETARDANCY
UL Listed Type OFCP NFPA262 and FT6 (CSA C22.2 No. 232)
12 FIBER DZ-ILA SERIES CABLE
Water Blocking Aramid Yarn Strength Members
900µm Tight Buffered Optical Fiber
Acrylate Fiber Coating
Indoor/Outdoor Low-Smoke PVC Jacket
24 FIBER DZ-ILA SERIES CABLE
Acrylate Fiber Coating
Water Blocking Aramid Yarn Strength Members
900μm Tight Buffered Optical Fiber
Indoor/Outdoor Low-Smoke PVC Jacket
OCC ASHEVILLE, NC
Enterprise Connectivity Manufacturing Facility 33 Superior Way Swannanoa, NC 28778 USA
828.298.2260 or 800.880.7674
VISIT US AT
OCCFIBER.COM
OCC DALLAS, TX
Harsh Environment and Specialty Connectivity Manufacturing Facility 1700 Capital Avenue, Suite 150 Plano, TX 75074 USA
972.509.1500 or 877.509.1500
OCC ROANOKE, VA
Corporate Headquarters and Fiber Optic Cable Manufacturing Facility 5290 Concourse Drive Roanoke, VA 24019 USA
540.265.0690 or 800.622.7711
Offering the durability you expect from OCC, these Aluminum Interlocking Armored distribution cables provide all of the indispensable elements needed for Indoor and Indoor/Outdoor commercial applications while providing great value. Manufactured with Indoor/Outdoor grade low smoke PVC for plenum applications.
CABLE CHARACTERISTICS
FIBER COUNT DIAMETER MM
(IN)
WEIGHT KG/KM
(LBS/1,000FT)
TENSILE LOAD MINIMUM BEND RADIUS
INSTALLATION N
(LBS)
OPERATIONAL N
(LBS)
INSTALLATION CM
(IN) LONG-TERM CM (IN)
4 12.6 (0.50) 140 (94) 660 (150) 200 (45) 25.2 (9.9) 18.9 (7.4)
6 12.6 (0.50) 142 (95) 660 (150) 200 (45) 25.2 (9.9) 18.9 (7.4)
8 13.1 (0.52) 153 (103) 660 (150) 200 (45) 26.2 (10.3) 19.7 (7.8)
12 13.6 (0.54) 169 (114) 660 (150) 200 (45) 27.2 (10.7) 20.4 (8.0)
18 14.6 (0.57) 196 (131) 1320 (300) 400 (90) 29.2 (11.5) 21.9 (8.6)
24 14.6 (0.57) 202 (135) 1320 (300) 400 (90) 29.2 (11.5) 21.9 (8.6)
Aluminum Interlocking Armor
Indoor/Outdoor Low Smoke PVC Jacket
Indoor/Outdoor Low Smoke PVC Jacket Aluminum
Interlocking Armor
DZ-ILA SERIES
PLENUM INDOOR/OUTDOOR SPECIFICATIONS
| ORDERING INFORMATION* | Minimum Laser Effective Modal Bandwidth (EMB) |
| ** | For backward compatibility to LED based systems, overfilled launch (OFL) |
| ˆ | 1310 nm CWDM lasers (10GBASE-LX4) |
| 1 | Reach assuming 3.0 dB maximum cabled attenuation at 850 nm and 1.3 dB |
total connection and splice loss 2 Supports 220 meter 10GBASE-LRM distance, or 300 meter 10GBASE-LRM distance with 300 meter capable equipment 3 3.5/1.5 dB/km maximum attenuation applies for all D-Series cables greater than 36 fibers, and for all D-Series cables with armor (corrugated steel tape or interlocked armor) or any other secondary outer jacketing
| 4 | 10 km for 1310 nm 1000BASE-LX10, and 5 km for 1310 nm 1000BASE-LX | |
| 5 | 10 km for 1310 nm 10GBASE-LR, and 40 km for 1550 nm 10GBASE-ER | |
| 6 | Typical Mode Field Diameter at 1310 nm Box No: 1 – 2 | Distribution Series Ultra-Fox Cable = DZ |
| 3 – 5 | Fiber Count = 004–024 |
| 6 | Jacket Type: Indoor/Outdoor Low Smoke PVC = T |
| 7 – 9 | Fiber Code: (See Table Above) |
| 10 | Ultra-Fox Fiber with 900µm Tight-Buffer = 9 |
| 11 | Standard Jacket Color: |
| Any Fiber Type: Black = K | |
| Multimode (OM1): Orange = O | |
| Multimode (OM3, OM4): Aqua = Q | |
| Single-Mode (SLX, SLA): Yellow = Y | |
| 12 | Rating: Plenum = P |
| 13-14 | Reinforcement: Aluminum Interlocking Armor (ILA) with Indoor/Outdoor Low |
Smoke PVC = I8
LASER GRADE FIBER PERFORMANCE
Fiber Code7
Industry Standard Designation
Core/ Cladding
Diameter (µm)
Numeric Aperture
Wavelength (nm)
Gigabit Ethernet
Distance (m)
10-Gigabit Ethernet
Distance (m)
Max. Cabled Attenuation
(dB/km)
Minimum Laser EMB Bandwidth*
(MHz-km)
Minimum OFL LED Bandwidth**
(MHz-km)
WLS
OM1
ISO/IEC11801
62.5/125 0.275 850/1310 300/600 33/300^ 3.5/1.5 220/500 200/500
ALT
Laser Optimized OM3
Bend Insensitive
ISO/IEC 11801
50/125 0.20 850/1310 1000/600 300/300^2 3.5/1.53 2000/500 1500/500
ALE
Laser Optimized OM4
Bend Insensitive
ISO/IEC 11801
50/125 0.20 850/1310 1040/600 550/300^2 3.5/1.53 4700/500 3500/500
SLX
Low Water Peak Single-Mode
ITU-T G.652.D
96/125 — 1310/1550 5 km4 10 km5 0.5/0.5 — —
SLA
Bend Insensitive, Low Water Peak Single-Mode ITU-T G.657.A1 and
ITU-T G.652.D
96/125 — 1310/1550 5 km4 10 km5 0.5/0.5 — —
D Z T 9 P
1 2 3 4 5 6 7 8 9 10 11 12 13 14
FIBER COUNT JACKET
TYPE
FIBER CODE TIGHT
BUFFER
JACKET
COLOR
RATING REINFORCEMENT
12 Fiber Indoor/Outdoor Cable Using Laser Ultra-FoxTM Low Water Peak, Bend Insensitive, Single-Mode Fiber, Plenum Rated, Yellow Jacket, with Aluminum Interlocking Armor (ILA)
Example:
D Z 0 1 2 T S L X 9 Y P I 8
I 8
10/24
SERIES
Gretchen
DZ012TALE9QP
A
B
C
D
E
234567
A
B
C
D
E
1234567
ECNDATEDESCRIPTIONSHTREV
REVISION HISTORY
CHECKED
THIRD
ANGLE
PROJECTION
C
FINISH
MATERIAL
2 PLACE DECIMALS ±.03"
3 PLACE DECIMALS ±.015"
ANGLES ±1/2°
FRACTIONS ±1/32"
TOLERANCES:
DIMENSIONS ARE IN INCHES
UNLESS OTHERWISE SPECIFIED
FILENAME
DATE
NEXT DWG
PREVIOUS DWG
APPROVED
ENGINEER
CHECKED
DRAWN
SHEETSCALE:
REVDWG NO.SIZECRITICAL DIMENSION CODE
F = FUNCTION
M = MATING
A = AUDIT
DATE
DATE
DATE
THIS DRAWING AND THE DESIGN SHOWN ARE THE
PROPERTY OF OPTICAL CABLE CORPORATION AND
MAY NOT BE USED AS THE BASIS FOR MANUFACTURE
OR SALE WITHOUT SPECIFIC WRITTEN PERMISSION
OF OPTICAL CABLE CORPORATION.
DWG TITLE
33 Superior Way Swannanoa, NC 28778 Phone: 828-298-2260 Fax: 828-298-2487 www.occfiber.com
UNCONTROLLED COPY
NONE
SEE BILL OF MATERIAL
SEE NOTES
D.A.HOLBERT
1/14/14
1/14/14
J.YANIK
1/24/14S.PORACH
1/24/14J.HOWE
AC111656
A 1/14/14 NEWRELEASE NEWALL JH
SQUARE CABLE GROMMETS
REAR COVER
FRONT TOP WINDOW
RTC1U-3APB (SHOWN)
FRONT VIEW
(TOP WINDOW REMOVED FOR CLARITY)
RTC1U-3APB (SHOWN)
REAR VIEW
MOUNTING BRACKETS
(2 REQ'D PER ASSEMBLY)
WITH MOUNTING SCREWS
19.00" REF
CABINET ASSEMBLY, RTC1U,
RACK MNT SLIDING, 3 PLATES
OCC PART NO. DESCRIPTION
RTC1U-3APB CABINET, RACK MNT, RTC, 1 UNIT, 3 ADAPTER PLATES, BLACK
CUSTOMER DRAWING,
C111656S1A.dft
"OPTICAL CABLE CORPORATION (OCC)
RESERVES THE RIGHT TO REVISE ANY
RACK CABINET SPECIFICATIONS."
UNCONTROLLED COPY
HINGED FRONT
WINDOW
SLAM LATCH
SPECIFICATIONS
FEATURES & BENEFITS:
- OPTICAL CABLE CORPORATION'S, RTC1U SERIES LOW PROFILE FIBER OPTIC CROSS CONNECT ENCLOSURES PROVIDE FIBER MANAGEMENT, CONNECTIVITY, AND DISTRIBUTION FOR 6-36 FIBERS.
ACCOMMODATES ALL CROSS CONNECT FUNCTIONS (SPLICING, TERMINATION, AND INTERCONNECTION)
FOR OUTSIDE PLANT, BACKBONE, AND BUILDING CABLES.
- ACCOMMODATES OCC 600 SERIES SNAP-IN ADAPTER PLATES. RTC1U ENCLOSURE PORT COUNT IS BASED UPON THE PORT DENSITY OF THE ADAPTER PLATES. ADAPTER PLATES ORDERED SEPARATELY.
- RTC1U ENCLOSURES PROVIDE INNOVATIVE FIBER ORGANIZATION UTILIZING STACKABLE FIBER HOOPS DESIGNED TO MAINTAIN ORDERLY FIBER MANAGEMENT AND ALLOW FOR GREATER SEGREGATION OF
INCOMING FIBER CABLES
- PLASTIC GROMMETS PROVIDE RELIABLE CABLE PROTECTION AT ALL CABLE ENTRANCES AND EXITS.
- RUGGED 16-GAUGE STEEL CONSTRUCTION WITH A DURABLE POWDER COAT FINISH.
RTC1U DRAWER COLOR: B = BLACK
- HINGED TRANSPARENT COVER ALLOWS FOR VISUAL INSPECTION OF PORTS AND DEFINED LABELING
FIELD PROVIDED FOR TIA 606A COMPLIANCE.
- STANDARD UNIVERSAL MOUNTING BRACKETS INCLUDED TO FIT 19" AND 23" RACKS OR CABINETS.
OPTIONAL RECESS BRACKETS ARE AVAILABLE TO ALLOW RTC1U ENCLOSURES TO FIT FLUSH WITH RACK
- ALL PLASTIC COMPONENTS ARE HIGH-IMPACT SELF-EXTINGUISHING, UL LISTED RATING 94 V-0.
- SPLICE TRAY KIT(S) AND EXTERNAL STRAIN RELIEF BRACKETS MAY BE ORDERED SEPARATELY AS AN
OPTION FOR THE RTC1U ENCLOSURE.
17.20" REF
1.71" REF
16.6" REF
THIRD
ANGLE
PROJECTION
B
MATERIAL
FILENAME
DATE
NEXT DWG
PREVIOUS DWG
APPROVED
ENGINEER
CHECKED
DRAWN
SHEETSCALE:
REVDWG NO.SIZECRITICAL DIMENSION CODE
= FUNCTION
DATE
DATE
DATE
FINISH
F M A
= MATING
= AUDIT NONE 1 OF 1
DWG TITLE
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES.
TOLERANCES: FRACTIONS ±1/32"
ANGLES ±1/2°
3 PLACE DECIMALS ±.005"
2 PLACE DECIMALS ±.01"
UNCONTROLLED COPY
B
SEE BILL OF MATERIAL
C113358B.dft
SEE NOTES C113358
CUSTOMER DRAWING,
SPLICE CASSETTE ASSEMBLY,
LC ADAPTER PLATE (LOADED)
THIS DRAWING AND THE DESIGN SHOWN ARE THE
PROPERTY OF OPTICAL CABLE CORPORATION AND
MAY NOT BE USED AS THE BASIS FOR MANUFACTURE
OR SALE WITHOUT SPECIFIC WRITTEN PERMISSION
OF OPTICAL CABLE CORPORATION.
5290 Concourse Drive Roanoke, VA 24019 Phone: 800-622-7711 Fax: 540-265-0724 www.occfiber.com
UNCONTROLLED COPY
"OPTICAL CABLE CORPORATION (OCC)
RESERVES THE RIGHT TO REVISE ANY
AND ALL DESIGN SPECIFICATIONS."
11/18/19J.YANIK
11/18/19D.HOLBERT
9/3/20J.CALLOWAY
11/21/19J.HOWE
OCC PART NO. DESCRIPTION
SPLICE CASSETTE, B & C, LC X 6, DUPLEX, 62.5µm OM1, SPLICE, WITH FAN-OUT SPLICE CASSETTE, B & C, LC X 6, DUPLEX, 50µm OM2, SPLICE, WITH FAN-OUT SPLICE CASSETTE, B & C, LC X 6, DUPLEX, 50µm OM3, SPLICE, WITH FAN-OUT SPLICE CASSETTE, B & C, LC X 6, DUPLEX, 50µm OM4, SPLICE, WITH FAN-OUT SPLICE CASSETTE, B & C, LC X 6, DUPLEX, 50µm OM5, SPLICE, WITH FAN-OUT
SPLICE CASSETTE, B & C, LC X 6, DUPLEX, SM, SPLICE, WITH FAN-OUT
SPLICE CASSETTE, B & C, LC X 6, DUPLEX, APC, SPLICE, WITH FAN-OUT
FSCS112DLCP
FSCS212DLCP
FSCS312DLCP
FSCS412DLCP
FSCS512DLCP
FSCS812DLCP
FSCSA12DLCP
OPENED VIEW
NOTES: UNLESS OTHERWISE SPECIFIED.
1. INCLUDES SUPPLIED HARDWARE:
(15) SLEEVE, FIBER PROTECTION, 40mm LONG
(1) CLAMP, CABLE ENTRY, SPLICE CASSETTE
COVER
(1) HOLDER, 12 SPLICE SLEEVE, SPLICE CASSETTE
BASE
CAP12SMDLC with FAN-OUT
(SHOWN FOR CLARITY)
(QTY 1) 12 PORT
ADAPTER PLATE
COMPLETED ASSEMBLY
(REAR VIEW)
CLAMP
(QTY 1)
FIBER SLEEVE
(QTY 15)
HOLDER
(QTY 1)
6.20"
4.96"
1.16"
0.95"
3.96"
| Lolo National Forest |
| OCC Cat 6 Sub-request.pdf |
| Page 1 |
| OCC fiber Sub-request.pdf |
| Page 1 |
| NAME: |
| TYPE: |
| QUANTITY: |
| APPLICATION: [ ] |
| DIAMETER: [ ] |
| ILLUMINATION: [ ] |
| MOUNTING: [ ] |
| CORD: [ ] |
| LEDCCT: [ ] |
| VOLTAGE: [ ] |
| FINISH: [ ] |
| GLOBE/LENS: [ ] |
| DIMMING: [ ] |
| EMERGENCY: [ ] |
| MOUNTING ACCESSORIES: [ ] |
| WIREGUARD: [ ] |
File details come from the government source that posted it. Updated .